WorldWideScience

Sample records for environmental sample collection

  1. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  2. Isolation of Arcobacter butzleri in environmental and food samples collected in industrial and artisanal dairy plants

    Directory of Open Access Journals (Sweden)

    Federica Giacometti

    2013-10-01

    Full Text Available This study investigated the presence of Arcobacter species in two cheese factories; a total of 22 environmental samples and 10 food samples were collected from an artisanal and an industrial cheese factory; Arcobacter species were isolated after enrichment, and isolates were identified at species level by multiplex-polymerase chain reaction (PCR assay. In the artisanal cheese factory, Arcobacter spp. were isolated from several environmental samples, cow and water buffalo raw milk and ricotta cheese. In the industrial plant, Arcobacter spp. were isolated from surfaces not in contact with food and from a cleaned surface in contact with food; no Arcobacter spp. was isolated from food. All isolates were identified as A. butzleri. We report of the presence of A. butzleri in a ready-to-eat cheese produced for retail. In addition, the isolation of A. butzleri in food processing surfaces in the two cheese factories could be assessed as a source of potential contamination for cheeses

  3. Determination of 36Cl in environmental samples collected in the JCO by AMS

    International Nuclear Information System (INIS)

    Seki, R.; Tsukuba Univ., Ibaraki; Arai, D.; Nagashima, Y.; Takahashi, T.; Matsuhiro, T.; Imanaka, T.

    2003-01-01

    Long-lived chlorine, 36 Cl (T 1/2 = 301,000 y) in environmental samples has been measured by the AMS system installed in Tandem Accelerator Center, University of Tsukuba. A tri-carbon-molecular 12 C 3 - pilot beam method is used to stabilize the terminal voltage of the tandem. A small amount of pure carbon graphite is well mixed into a AgCl target material for creating Cl - and 12 C 3 - in the ion source. A 36 S isobaric interference in the system is eliminated to determine 36 Cl in environmental samples by chemical procedure. Some samples containing chlorine such as soil, chemical reagents and table salt have been collected in the JCO criticality accident site and analyzed to detect neutron-induced 36 Cl. The experimental result has been compared with a theoretical calculation. (author)

  4. Environmental sampling

    International Nuclear Information System (INIS)

    Puckett, J.M.

    1998-01-01

    Environmental Sampling (ES) is a technology option that can have application in transparency in nuclear nonproliferation. The basic process is to take a sample from the environment, e.g., soil, water, vegetation, or dust and debris from a surface, and through very careful sample preparation and analysis, determine the types, elemental concentration, and isotopic composition of actinides in the sample. The sample is prepared and the analysis performed in a clean chemistry laboratory (CCL). This ES capability is part of the IAEA Strengthened Safeguards System. Such a Laboratory is planned to be built by JAERI at Tokai and will give Japan an intrinsic ES capability. This paper presents options for the use of ES as a transparency measure for nuclear nonproliferation

  5. Methods for the collection of subsurface samples during environmental site assessments

    International Nuclear Information System (INIS)

    Weinstock, E.A.

    1996-01-01

    This paper discusses numerous sample collection techniques that have been successfully employed during Phase 2 Assessments and presents case histories of their application. Pollutants of concern include PCE and petroleum. The collection of shallow soil samples is described using commercially available hand augers and hand-driven core samplers. These devices are modified with extensions to collect deeper samples from storm drains and leaching pools. The performance of soil gas surveys are described using both hand-driven sample probes and vehicle-mounted, hydraulically driven vapor probes. Once the soil vapor is collected at the ground surface, a sample of the media is either analyzed on-site using a field-operated detection device or delivered to a laboratory for analysis. Application and case histories of the Geoprobe(trademark)sampling system, a form of direct push technology, are described. This device uses vehicle-mounted, hydraulically-driven sample probes. The probe can be advanced to depths as great as 100 feet below grade and can retrieve soil, soil gas and groundwater samples

  6. Prevalence of L. monocytogenes in environmental samples collected in dairy plants of Sassari Province, Italy

    Directory of Open Access Journals (Sweden)

    Giovanni Terrosu

    2015-09-01

    Full Text Available Listeria (L. monocytogenes is frequently isolated from food production environment and often persists in dairy plants despite vigorous sanitation regimes. In recent years several alert notifications were sent to Rapid Alert System for Food Products system as a consequence of Listeria monocytogenes contamination of ricotta cheese. After the alert of 2012, competent authority (Local Health Unit of Sassari Province organised an environmental monitoring plan with the partnership of the Institute for Experimental Veterinary Medicine of Sardinia to verify analysis of dairy plants own-check according to Regulation (EC N° 2073/05 and further modifications. In 2014 n. 665 processing areas samples of n. 50 dairy plants of Sassari Province were examined. UNI EN ISO 11290-1:2005 for detection of L. monocytogenes was used. Non-compliance in n. 5 diary plants are observed (n. 8 positive samples. Post-non-compliance environmental sanitisation was efficient and own-check plans included appropriate corrective actions.

  7. Collection and preparation of samples for Agency's programme of intercalibration methods and procedures for measurement of environmental radioactivity

    International Nuclear Information System (INIS)

    Patel, B.

    1975-12-01

    In the period of 1971-1975 several samples of marine sediment and organisms were collected from the Bombay Harbour Bay as well as from the vicinity of the Tarapur nuclear power station in order to supply the materials for preparing intercalibration samples for radionuclides measurements. All samples collected were freeze-dried and homogenized prior to the dispatch to the Monaco Laboratory, where final homogenization and the homogeneity tests were carried out. Altogether 2 marine organisms and 3 marine sediments were supplied during this period. The materials supplied were proved to be useful to prepare intercalibration samples for radionuclide measurements in the levels for monitoring operations. Based on these materials several intercalibration exercises were successfully conducted. This work thus formed a basis for bringing the better comparability of radionuclide measurements in marine environmental samples in an international scale

  8. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Science.gov (United States)

    2010-01-01

    ... laboratory within one day. If delivery is delayed, samples should be refrigerated. (a) For egg- and meat-type chickens, waterfowl, exhibition poultry, and game birds. All samples and swabs described in this paragraph...

  9. [Detection of Avian Influenza Virus in Environmental Samples Collected from Live Poultry Markets in China during 2009-2013].

    Science.gov (United States)

    Zhang, Ye; Li, Xiaodan; Zou, Shumei; Bo, Hong; Dong, Libo; Gao, Rongbao; Wang, Dayan; Shu, Yuelong

    2015-11-01

    Abstract: To investigate the distribution of avian influenza virus in environmental samples from live poultry markets (LPM) in China, samples were collected and tested by nucleic acid during 2009-2013 season. Each sample was tested by real-time RT PCR using flu A specific primers. If any real-time PCR was positive, the sample was inoculated into specific-pathogen-free (SPF) embryonated chicken eggs for viral isolation. The results indicated that the positive rate of nucleic acid in enviromental samples exhibited seasonality. The positive rate of nucleic acid was significantly higher in Winter and Spring. The positive rate of nucleic acid in LPM located in the south of China was higher than in northern China. Samples of Sewage for cleaning poultry and chopping board showed that higher positive rate of nucleic acid than other samples. The Subtype identification showed that H5 and H9 were main subtypes in the enviromental samples. Viral isolation indicated H5 subtypes was more than H9 subtypes between 2009 and 2013 while H9 subtypes increased in 2013. Our findings suggested the significance of public health based on LPM surveillance and provided the basis of prevention and early warning for avian flu infection human.

  10. Sample collection and documentation

    International Nuclear Information System (INIS)

    Cullings, Harry M.; Fujita, Shoichiro; Watanabe, Tadaaki; Yamashita, Tomoaki; Tanaka, Kenichi; Endo, Satoru; Shizuma, Kiyoshi; Hoshi, Masaharu; Hasai, Hiromi

    2005-01-01

    Beginning within a few weeks after the bombings and periodically during the intervening decades, investigators in Hiroshima and Nagasaki have collected samples of materials that were in the cities at the time of the bombings. Although some early efforts were not driven by specific measurement objectives, many others were. Even some of the very earliest samples collected in 1945 were based on carefully conceived research plans and detailed specifications for samples appropriate to particular retrospective measurements, i.e., of particular residual quantities remaining from exposure to the neutrons and gamma rays from the bombs. This chapter focuses mainly on the work of groups at two institutions that have actively collaborated since the 1980s in major collection efforts and have shared samples among themselves and with other investigators: the Radiation Effects Research Foundation (RERF) and its predecessor the Atomic Bomb Casualty Commission (ABCC), and Hiroshima University. In addition, a number of others are listed, who also contributed to the literature by their collection of samples. (J.P.N.)

  11. Radioactivity in environmental samples

    International Nuclear Information System (INIS)

    Fornaro, Laura

    2001-01-01

    The objective of this practical work is to familiarize the student with radioactivity measures in environmental samples. For that were chosen samples a salt of natural potassium, a salt of uranium or torio and a sample of drinkable water

  12. ICP-MS measurements of iodine and bromine in environmental samples collected along the Kuji River, Japan

    International Nuclear Information System (INIS)

    Kushita, Kouhei N.; Amano, Hikaru

    2003-01-01

    From a viewpoint of monitoring the distribution and transfer of long-lived radioiodine ( 129 I) and possible hazardous brominated substances, I and Br contents in various environmental samples collected in the Kuji River area, Japan, were studied by ICP-MS. The feature of the change in concentrations of I and Br, as well as those of other general properties such as pH etc., in Kuji River watershed were coincident with each other. It is considered from the obtained data that the environmental conditions, especially those of the soil of the area, mainly control the distribution of I and Br in the river water. The circulation characteristics of I and Br showed different features in different transfer media, which could be ascribed to the different chemical properties of these elements in each media. It was also shown that the distributions of I and Br are varied even within a small zone of about 20 km width around a high mountain of this area, which is also considered to reflect the environmental characteristics of the district. (author)

  13. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1993-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). Samples are routinely collected and analyzed to determine the quality of air, surface water, ground water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Drinking Water Project, and Ground-Water Surveillance Project.

  14. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1997-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL)(a) for the US Department of Energy (DOE). This document contains the planned 1997 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. In addition, Section 3.0, Biota, also reflects a rotating collection schedule identifying the year a specific sample is scheduled for collection. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program, and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling methods will be the same as those described in the Environmental Monitoring Plan, US Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 1, US Department of Energy, Richland, Washington

  15. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program

  16. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program.

  17. Collecting Samples for Testing

    Science.gov (United States)

    ... Creatinine Ratio Valproic Acid Vancomycin Vanillylmandelic Acid (VMA) VAP Vitamin A Vitamin B12 and Folate Vitamin D ... that used for CSF in that they require aspiration of a sample of the fluid through a ...

  18. Evaluation of some pollutant levels in environmental samples collected from the area of the new campus of Taif University.

    Science.gov (United States)

    Sharshar, Taher; Hassan, H Ebrahim; Arida, Hassan A; Aydarous, Abdulkadir; Bazaid, Salih A; Ahmed, Mamdouh A

    2013-01-01

    The levels of radioactivity and heavy metals in soil, plant and groundwater samples collected from the area of the new campus of Taif University, Saudi Arabia, and its neighbouring areas have been determined. High-resolution gamma-ray spectroscopy was used for radioactivity measurements, and inductively coupled plasma atomic emission spectroscopy was used to determine the concentration of heavy metals. The means of (226)Ra, (228)Ra and (40)K concentrations in water samples collected from four wells were found to be 0.13 ± 0.03, 0.05 ± 0.03 and 1.3 ± 0.5 Bq l(-1), respectively. The means of (238)U, (226)Ra, (228)Ra ((232)Th for soil samples) and (40)K concentrations in wild plant and soil samples were found to be 3.7 ± 4.1, 8.8 ± 11.6, 3.8 ± 2.9 and 1025 ± 685, and 8.6 ± 3.4, 12.8 ± 3.4, 16.6 ± 7.1 and 618 ± 82 Bq kg(-1) dry weight (DW), respectively. The (137)Cs of artificial origin was also detected in soil samples with a mean concentration of 3.8 ± 2.2 Bq kg(-1) DW. Evaluating the results, it can be concluded that the concentrations of (238)U, (226)Ra, (232)Th and (40)K in soil samples fall within the world average. Furthermore, 19 trace and major elements in groundwater samples and 22 elements in soil and plant samples were determined. The sampling locations of soil can be classified into three groups (relatively high, medium and low polluted) according to their calculated metal pollution index using the contents of trace and major elements. A cluster analysis of the contents of radioactivity and trace element contents in soil samples shows the presence of two main distinct clusters of sampling locations.

  19. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site

  20. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.

  1. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons

  2. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons.

  3. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L E

    1992-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. Samples for radiological analyses include Air-Particulate Filter, gases and vapor; Water/Columbia River, Onsite Pond, Spring, Irrigation, and Drinking; Foodstuffs/Animal Products including Whole Milk, Poultry and Eggs, and Beef; Foodstuffs/Produce including Leafy Vegetables, Vegetables, and Fruit; Foodstuffs/Farm Products including Wine, Wheat and Alfalfa; Wildlife; Soil; Vegetation; and Sediment. Direct Radiation Measurements include Terrestrial Locations, Columbia River Shoreline Locations, and Onsite Roadway, Railway and Aerial, Radiation Surveys.

  4. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  5. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  6. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  7. Molecular detection of native and invasive marine invertebrate larvae present in ballast and open water environmental samples collected in Puget Sound

    Science.gov (United States)

    Harvey, J.B.J.; Hoy, M.S.; Rodriguez, R.J.

    2009-01-01

    Non-native marine species have been and continue to be introduced into Puget Sound via several vectors including ship's ballast water. Some non-native species become invasive and negatively impact native species or near shore habitats. We present a new methodology for the development and testing of taxon specific PCR primers designed to assess environmental samples of ocean water for the presence of native and non-native bivalves, crustaceans and algae. The intergenic spacer regions (IGS; ITS1, ITS2 and 5.8S) of the ribosomal DNA were sequenced for adult samples of each taxon studied. We used these data along with those available in Genbank to design taxon and group specific primers and tested their stringency against artificial populations of plasmid constructs containing the entire IGS region for each of the 25 taxa in our study, respectively. Taxon and group specific primer sets were then used to detect the presence or absence of native and non-native planktonic life-history stages (propagules) from environmental samples of ballast water and plankton tow net samples collected in Puget Sound. This methodology provides an inexpensive and efficient way to test the discriminatory ability of taxon specific oligonucleotides (PCR primers) before creating molecular probes or beacons for use in molecular ecological applications such as probe hybridizations or microarray analyses. This work addresses the current need to develop molecular tools capable of diagnosing the presence of planktonic life-history stages from non-native marine species (potential invaders) in ballast water and other environmental samples. ?? 2008 Elsevier B.V.

  8. Vertical distribution and environmental significance of sulfur and oxygen heterocyclic aromatic hydrocarbons in soil samples collected from Beijing, China

    International Nuclear Information System (INIS)

    Zhang Zhihuan; He Fengpeng; Bu Qingwei; Lu Song

    2008-01-01

    Vertical distribution of the concentration and composition of some sulfur and oxygen heterocyclic aromatic hydrocarbons (SOHAHs), such as, fluorene, dibenzofuran, dibenzothiophene and their alkyl homologues in 10 soil profiles in Beijing have been investigated. The results showed that the concentrations and composition of SOHAHs in topsoil (0-30 cm) from different profiles are different. The concentrations of SOHAHs in topsoils are much higher than that in bottom soils where the concentrations are relatively constant. The fingerprints of SOHAHs from same profile are similar in topsoil samples, which are obviously different at the deep part, which suggested that the sources of these compounds are consistent in topsoil and are discriminating between surface and bottom soils. The main sources of SOHAHs in surface soil were fossil fuel combustion, petroleum and wastewater irrigation, while those at deep part were likely derived from the degradation products of soil organic matters. - The vertical distribution of SOHAHs was provided and possible sources were different between topsoils and deep part

  9. Environmental radiation levels in soil and sediment samples collected from floating water from a land runway resulting from heavy rains in the Jeddah region, KSA

    International Nuclear Information System (INIS)

    Mohery, M.; Baz, Shadiah; Kelany, Adel M.; Abdallah, A.M.

    2014-01-01

    The natural radiation levels in soil and sediment samples collected from floating water from a land runway resulting from heavy rains in the Jeddah region as well as the activity in the population of its surrounding environments were studied. In the regions surrounding Jeddah, the movements of floating water may increase the concentration of radioactivity due to the movement of soil due to heavy rains. In addition, the technological development of industry, agriculture and other sources around the Jeddah region has increased environmental pollution, resulting in noticeable concentrations of radioactivity. The measured activity concentrations of 214 Pb, 214 Bi, 228 Ac, 208 Tl, 40 K, 226 Ra and 228 Ra in the studied area suggest that they are within the world average for soils and sediments, except those for water sample no. 4; the concentration in this sample was five times higher than the world average concentration (this water is not consumable). Herein, the radioactivity concentrations that were obtained from the analysis of soil and sediment samples that were collected from the investigated area are discussed. Additionally, the absorbed dose rate (D), radium equivalent activity (Ra eq ), external hazard index (H ex ), annual gonadal dose equivalent (AGDE) and annual effective dose equivalent (AEDE) were evaluated. For the soil and sediment samples, the average radioactivity concentrations were determined for each site and are expressed in Becquerels per kilogram (Bq/kg) of dry weight, while for the measurement of both the 226 Ra and 228 Ra isotopes in the water samples, the activity concentration is expressed in picoCuries per liter (pCi/l). The obtained results were compared with other measurements from different countries. The movement of floating water around the Jeddah region increases the concentration of radioactivity due to the movement of soils with heavy rains. - Highlights: • The natural radiation levels in soil and sediment samples from floating

  10. Environmental sampling for trace analysis

    International Nuclear Information System (INIS)

    Markert, B.

    1994-01-01

    Often too little attention is given to the sampling before and after actual instrumental measurement. This leads to errors, despite increasingly sensitive analytical systems. This is one of the first books to pay proper attention to representative sampling. It offers an overview of the most common techniques used today for taking environmental samples. The techniques are clearly presented, yield accurate and reproducible results and can be used to sample -air - water - soil and sediments - plants and animals. A comprehensive handbook, this volume provides an excellent starting point for researchers in the rapidly expanding field of environmental analysis. (orig.)

  11. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    2000-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program: and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling design is described in the Operations Office, Environmental Monitoring Plan, United States Department of Energy, Richland DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY 2000 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2000 in which case the anticipated year for collection is provided. In addition, a map showing approximate sampling locations is included for each media scheduled for collection

  12. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1999-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, ''General Environmental protection Program,'' and DOE Order 5400.5, ''Radiation Protection of the Public and the Environment.'' The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY1999 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes the sampling location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be collected in 1999 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing approximate sampling locations

  13. Hanford site environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1998-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1 open-quotes General Environmental Protection Program,close quotes and DOE Order 5400.5, open-quotes Radiation Protection of the Public and the Environment.close quotes The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 2, U.S. Department of Energy, Richland, Washington. This document contains the 1998 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section of this document describes the planned sampling schedule for a specific media (air, surface water, biota, soil and vegetation, sediment, and external radiation). Each section includes the sample location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be planned for 1998 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing sample locations

  14. Diagnostic herd sensitivity using environmental samples

    DEFF Research Database (Denmark)

    Vigre, Håkan; Josefsen, Mathilde Hartmann; Seyfarth, Anne Mette

    either at farm or slaughter. Three sample matrices were collected; dust samples (5 environmental swabs), nasal swabs (10 pools with 5 animals per pool) and air samples (1 filter). Based on the assumption that MRSA occurred in all 48 herds the overall herd sensitivity was 58% for nasal swabs, 33% for dust....... In our example, the prevalence of infected pigs in each herd was estimated from the pooled samples of nasal swabs. Logistic regression was used to estimate the effect of animal prevalence on the probability to detect MRSA in the dust and air samples at herd level. The results show a significant increase...

  15. Soil sampling for environmental contaminants

    International Nuclear Information System (INIS)

    2004-10-01

    The Consultants Meeting on Sampling Strategies, Sampling and Storage of Soil for Environmental Monitoring of Contaminants was organized by the International Atomic Energy Agency to evaluate methods for soil sampling in radionuclide monitoring and heavy metal surveys for identification of punctual contamination (hot particles) in large area surveys and screening experiments. A group of experts was invited by the IAEA to discuss and recommend methods for representative soil sampling for different kinds of environmental issues. The ultimate sinks for all kinds of contaminants dispersed within the natural environment through human activities are sediment and soil. Soil is a particularly difficult matrix for environmental pollution studies as it is generally composed of a multitude of geological and biological materials resulting from weathering and degradation, including particles of different sizes with varying surface and chemical properties. There are so many different soil types categorized according to their content of biological matter, from sandy soils to loam and peat soils, which make analytical characterization even more complicated. Soil sampling for environmental monitoring of pollutants, therefore, is still a matter of debate in the community of soil, environmental and analytical sciences. The scope of the consultants meeting included evaluating existing techniques with regard to their practicability, reliability and applicability to different purposes, developing strategies of representative soil sampling for cases not yet considered by current techniques and recommending validated techniques applicable to laboratories in developing Member States. This TECDOC includes a critical survey of existing approaches and their feasibility to be applied in developing countries. The report is valuable for radioanalytical laboratories in Member States. It would assist them in quality control and accreditation process

  16. Collection and preparation of samples for gamma spectrometry

    International Nuclear Information System (INIS)

    Pan Jingquan

    1994-01-01

    The paper presents the basic principles of sample collection and preparation: setting up unified sampling program, methods and procedures, sample packing, transportation and storage, determination of sample quantity, sample pretreatment and preparation of samples to be analysed, etc. for gamma spectrometry. And the paper also describes briefly the main methods and special issues of sampling and preparation for the same environmental and biological samples, such as, air, water, grass, soil and foods

  17. Equipment for collecting samples of radioactive solutions

    International Nuclear Information System (INIS)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-01-01

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described

  18. Sampling quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces quality assurance guidance pertaining to the design and implementation of sampling procedures and processes for collecting environmental data for DOE's Office of EM (Environmental Restoration and Waste Management)

  19. Scientific guidelines for preservation of samples collected from Mars

    International Nuclear Information System (INIS)

    Gooding, J.L.

    1990-04-01

    The maximum scientific value of Martian geologic and atmospheric samples is retained when the samples are preserved in the conditions that applied prior to their collection. Any sample degradation equates to loss of information. Based on detailed review of pertinent scientific literature, and advice from experts in planetary sample analysis, number values are recommended for key parameters in the environmental control of collected samples with respect to material contamination, temperature, head-space gas pressure, ionizing radiation, magnetic fields, and acceleration/shock. Parametric values recommended for the most sensitive geologic samples should also be adequate to preserve any biogenic compounds or exobiological relics

  20. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2009-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  1. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2013-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  2. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2012-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  3. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2009-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author)

  4. Importance of sampling frequency when collecting diatoms

    KAUST Repository

    Wu, Naicheng; Faber, Claas; Sun, Xiuming; Qu, Yueming; Wang, Chao; Ivetic, Snjezana; Riis, Tenna; Ulrich, Uta; Fohrer, Nicola

    2016-01-01

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected

  5. Water sample-collection and distribution system

    Science.gov (United States)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  6. Biopolymers for sample collection, protection, and preservation.

    Science.gov (United States)

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  7. Biological Environmental Sampling Technologies Assessment

    Science.gov (United States)

    2015-12-01

    modular set of aerosol detector, collector, and identifier components. Before the award, the JBTDS program office engaged its combat developers and...collection and identification processes are not integrated into one unit. Concern was also expressed regarding operation of the smartphone -based Biomeme one3...DESCRIPTION (JBTDS) The Joint Biological Tactical Detection System (JBTDS) will be employed as a modular set of capabilities (detector, collector, and

  8. Osmium in environmental samples from Northeast Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Rodushkin, Ilia [Division of Applied Geology, Lulea University of Technology, S-971 87 Lulea (Sweden); ALS Laboratory Group, ALS Analytica AB, Aurorum 10, S-977 75 Lulea (Sweden)], E-mail: ilia.rodushkin@alsglobal.com; Engstroem, Emma [Division of Applied Geology, Lulea University of Technology, S-971 87 Lulea (Sweden); Soerlin, Dieke; Ponter, Christer; Baxter, Douglas C. [ALS Laboratory Group, ALS Analytica AB, Aurorum 10, S-977 75 Lulea (Sweden)

    2007-11-01

    Osmium (Os) concentrations and {sup 187}Os/{sup 188}Os isotope abundance ratios are presented for sedimentary materials, soils, humus, plants, mushrooms, mosses and lichens collected in the vicinity of the town of Lulea, Northeast Sweden, the data for biological specimens being the first reported. Contributions from sampling and varying exposure time to the observed environmental variability were evaluated. Sedimentary materials (from both fresh and brackish water) are most elevated in radiogenic {sup 187}Os, followed by inorganic soil horizons, mushrooms and humus. The Os isotopic compositions of plants, mosses and lichens are much less radiogenic, with mean {sup 187}Os/{sup 188}Os lying within a relatively narrow 0.3-0.6 range. Significant temporal variations in Os concentrations and isotopic compositions of plant samples are attributed to integrative uptake of airborne Os with non-radiogenic composition. Measured Os concentrations in biological matrices increase in the order: small shrub leaves (blueberry and lingonberry) {<=} spruce needles {<=} mushrooms {<=} tree leaves {<=} pine needles < mosses << lichens. The concentrations found in three different species of plant were used to provide the first estimates of gaseous osmium tetroxide (OsO{sub 4}) in the environment. Though the Os content of samples from Northeast Sweden does not differ significantly from matrix-matched international reference materials (not certified for Os) of abiotic origin, the estimates of gaseous OsO{sub 4} concentrations are roughly an order of magnitude higher than have been reported for particle-bound Os in other studies. The pronounced spatial variations between relatively closely situated sites in mean {sup 187}Os/{sup 188}Os ratios for samples of the same species (presumably with the same dominating uptake mechanism) point to the presence of different local Os sources. This study therefore demonstrates that emissions of Os from automobile catalytic converters are not the only

  9. Osmium in environmental samples from Northeast Sweden

    International Nuclear Information System (INIS)

    Rodushkin, Ilia; Engstroem, Emma; Soerlin, Dieke; Ponter, Christer; Baxter, Douglas C.

    2007-01-01

    Osmium (Os) concentrations and 187 Os/ 188 Os isotope abundance ratios are presented for sedimentary materials, soils, humus, plants, mushrooms, mosses and lichens collected in the vicinity of the town of Lulea, Northeast Sweden, the data for biological specimens being the first reported. Contributions from sampling and varying exposure time to the observed environmental variability were evaluated. Sedimentary materials (from both fresh and brackish water) are most elevated in radiogenic 187 Os, followed by inorganic soil horizons, mushrooms and humus. The Os isotopic compositions of plants, mosses and lichens are much less radiogenic, with mean 187 Os/ 188 Os lying within a relatively narrow 0.3-0.6 range. Significant temporal variations in Os concentrations and isotopic compositions of plant samples are attributed to integrative uptake of airborne Os with non-radiogenic composition. Measured Os concentrations in biological matrices increase in the order: small shrub leaves (blueberry and lingonberry) ≤ spruce needles ≤ mushrooms ≤ tree leaves ≤ pine needles 4 ) in the environment. Though the Os content of samples from Northeast Sweden does not differ significantly from matrix-matched international reference materials (not certified for Os) of abiotic origin, the estimates of gaseous OsO 4 concentrations are roughly an order of magnitude higher than have been reported for particle-bound Os in other studies. The pronounced spatial variations between relatively closely situated sites in mean 187 Os/ 188 Os ratios for samples of the same species (presumably with the same dominating uptake mechanism) point to the presence of different local Os sources. This study therefore demonstrates that emissions of Os from automobile catalytic converters are not the only source of contemporary environmental contamination

  10. Radiological analyses of Marshall Islands environmental samples, 1974--1976

    International Nuclear Information System (INIS)

    Greenhouse, N.A.; Miltenberger, R.P.; Cua, F.T.

    1977-01-01

    Results are reported from the radiological analysis of environmental samples collected in the Marshall Islands during 1974 through 1976. Most of the samples were collected on or near the Bikini Atoll and included plants, soil, fish, catchment water, and sediments, with emphasis on local marine and terrestrial food items. Data are presented from γ spectral analysis and the content of 90 Sr and transuranic elements in the samples

  11. Biopolymers for Sample Collection, Protection, and Preservation

    Science.gov (United States)

    2015-05-19

    knowledge of sample collection from various matrices is crucial. Recovery and preservation of microorganisms prior to analysis are important...Another method for encapsulating bacteria for use in biodegradation of gasoline involves a complex process using gellan gum (Moslemy et al. 2002). Many...use of acacia gum in preserving microorganisms for extended periods of time without refrigeration (Krumnow et al. 2009; Sorokulova et al. 2008, 2012

  12. Collection of biological samples in forensic toxicology.

    Science.gov (United States)

    Dinis-Oliveira, R J; Carvalho, F; Duarte, J A; Remião, F; Marques, A; Santos, A; Magalhães, T

    2010-09-01

    Forensic toxicology is the study and practice of the application of toxicology to the purposes of the law. The relevance of any finding is determined, in the first instance, by the nature and integrity of the specimen(s) submitted for analysis. This means that there are several specific challenges to select and collect specimens for ante-mortem and post-mortem toxicology investigation. Post-mortem specimens may be numerous and can endow some special difficulties compared to clinical specimens, namely those resulting from autolytic and putrefactive changes. Storage stability is also an important issue to be considered during the pre-analytic phase, since its consideration should facilitate the assessment of sample quality and the analytical result obtained from that sample. The knowledge on degradation mechanisms and methods to increase storage stability may enable the forensic toxicologist to circumvent possible difficulties. Therefore, advantages and limitations of specimen preservation procedures are thoroughfully discussed in this review. Presently, harmonized protocols for sampling in suspected intoxications would have obvious utility. In the present article an overview is given on sampling procedures for routinely collected specimens as well as on alternative specimens that may provide additional information on the route and timing of exposure to a specific xenobiotic. Last, but not least, a discussion on possible bias that can influence the interpretation of toxicological results is provided. This comprehensive review article is intented as a significant help for forensic toxicologists to accomplish their frequently overwhelming mission.

  13. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  14. Importance of sampling frequency when collecting diatoms

    KAUST Repository

    Wu, Naicheng

    2016-11-14

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected and analyzed daily riverine diatom samples over a 1-year period (25 April 2013–30 April 2014) at the outlet of a German lowland river. The samples were classified into five clusters (1–5) by a Kohonen Self-Organizing Map (SOM) method based on similarity between species compositions over time. ASFs were determined to be 25 days at Cluster 2 (June-July 2013) and 13 days at Cluster 5 (February-April 2014), whereas no specific ASFs were found at Cluster 1 (April-May 2013), 3 (August-November 2013) (>30 days) and Cluster 4 (December 2013 - January 2014) (<1 day). ASFs showed dramatic seasonality and were negatively related to hydrological wetness conditions, suggesting that sampling interval should be reduced with increasing catchment wetness. A key implication of our findings for freshwater management is that long-term bio-monitoring protocols should be developed with the knowledge of tracking algal temporal dynamics with an appropriate sampling frequency.

  15. Designing an enhanced groundwater sample collection system

    International Nuclear Information System (INIS)

    Schalla, R.

    1994-10-01

    As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at the Laboratory for Energy and Health-Related Research (LEHR), Pacific Northwest Laboratory (PNL) provided guidance on the design and construction of monitoring wells and identified the most suitable type of groundwater sampling pump and accessories for monitoring wells. The goal was to utilize a monitoring well design that would allow for hydrologic testing and reduce turbidity to minimize the impact of sampling. The sampling results of the newly designed monitoring wells were clearly superior to those of the previously installed monitoring wells. The new wells exhibited reduced turbidity, in addition to improved access for instrumentation and hydrologic testing. The variable frequency submersible pump was selected as the best choice for obtaining groundwater samples. The literature references are listed at the end of this report. Despite some initial difficulties, the actual performance of the variable frequency, submersible pump and its accessories was effective in reducing sampling time and labor costs, and its ease of use was preferred over the previously used bladder pumps. The surface seals system, called the Dedicator, proved to be useful accessory to prevent surface contamination while providing easy access for water-level measurements and for connecting the pump. Cost savings resulted from the use of the pre-production pumps (beta units) donated by the manufacturer for the demonstration. However, larger savings resulted from shortened field time due to the ease in using the submersible pumps and the surface seal access system. Proper deployment of the monitoring wells also resulted in cost savings and ensured representative samples

  16. Isotope dilution analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.; Korenova, Z.; Klas, J.; Klehr, E.H.

    1986-01-01

    Isotope dilution analysis has been used for the determination of several trace elements - especially metals - in a variety of environmental samples, including aerosols, water, soils, biological materials and geological materials. Variations of the basic concept include classical IDA, substoichiometric IDA, and more recently, sub-superequivalence IDA. Each variation has its advantages and limitations. A periodic chart has been used to identify those elements which have been measured in environmental samples using one or more of these methods. (author)

  17. Practical reporting times for environmental samples

    International Nuclear Information System (INIS)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4 degrees C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions

  18. Practical reporting times for environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4{degrees}C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions.

  19. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2011

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2011-01-21

    This document contains the calendar year 2011 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2011, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2011.

  20. Analysis procedure for americium in environmental samples

    International Nuclear Information System (INIS)

    Holloway, R.W.; Hayes, D.W.

    1982-01-01

    Several methods for the analysis of 241 Am in environmental samples were evaluated and a preferred method was selected. This method was modified and used to determine the 241 Am content in sediments, biota, and water. The advantages and limitations of the method are discussed. The method is also suitable for 244 Cm analysis

  1. PIXE - Analysis for environmental and biological samples

    International Nuclear Information System (INIS)

    Baptista, G.B.

    1980-04-01

    The usefulness and accuracy of PIXE as an analytical tool in the study of trace elements in environmental samples of the Brazilian Cerrado are discussed. The report lists actual and forthcoming publications resulting from the study. The mechanism of exchange of elements in solution in water to aerosols has been investigated. For details of the procedure the reader is referred to an earlier report

  2. Ground-water sample collection and analysis plan for the ground-water surveillance project

    International Nuclear Information System (INIS)

    Bryce, R.W.; Evans, J.C.; Olsen, K.B.

    1991-12-01

    The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives

  3. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2007

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2007-01-31

    This document contains the calendar year 2007 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2007 in which case the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2007.

  4. A method to combine non-probability sample data with probability sample data in estimating spatial means of environmental variables

    NARCIS (Netherlands)

    Brus, D.J.; Gruijter, de J.J.

    2003-01-01

    In estimating spatial means of environmental variables of a region from data collected by convenience or purposive sampling, validity of the results can be ensured by collecting additional data through probability sampling. The precision of the pi estimator that uses the probability sample can be

  5. Nuclear techniques for analysis of environmental samples

    International Nuclear Information System (INIS)

    1986-12-01

    The main purposes of this meeting were to establish the state-of-the-art in the field, to identify new research and development that is required to provide an adequate framework for analysis of environmental samples and to assess needs and possibilities for international cooperation in problem areas. This technical report was prepared on the subject based on the contributions made by the participants. A separate abstract was prepared for each of the 9 papers

  6. Environmental sample banking-research and methodology

    International Nuclear Information System (INIS)

    Becker, D.A.

    1976-01-01

    The National Bureau of Standards (NBS), in cooperation with the Environment Protection Agency and the National Science Foundation, is engaged in a research program establishing methodology for environmental sample banking. This program is aimed toward evaluating the feasibility of a National Environment Specimen Bank (NESB). The capability for retrospective chemical analyses to evaluate changes in our environment would provide useful information. Much of this information could not be obtained using data from previously analyzed samples. However, to assure validity for these stored samples, they must be sampled, processed and stored under rigorously evaluated, controlled and documented conditions. The program currently under way in the NBS Analytical Chemistry Division has 3 main components. The first is an extension survey of available literature concerning problems of contamination, losses and storage. The components of interest include trace elements, pesticides, other trace organics (PCBs, plasticizers, etc.), radionuclides and microbiological species. The second component is an experimental evaluation of contamination and losses during sampling and sample handling. Of particular interest here is research into container cleaning methodology for trace elements, with respect to adsorption, desorption, leaching and partial dissolution by various sample matrices. The third component of this program is an evaluation of existing methodology for long-term sample storage

  7. 28 CFR 28.12 - Collection of DNA samples.

    Science.gov (United States)

    2010-07-01

    ... Homeland Security, collecting DNA samples from: (1) Aliens lawfully in, or being processed for lawful... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection...

  8. Environmental sampling accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-06-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an on-line disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished by using computer-generated schedules, collection labels, and output/input cards. For each scheduled sample and analysis, a printed card is issued for collection, laboratory analysis, and counting. The cards also contain information needed by personnel performing the jobs, such as sample location, aliquot to be processed, or procedure number. Manual entries are made on the cards when each step in the process is completed. Additional pertinent data are also manually entered on the cards; e.g., entries are made explaining why a sample is not collected, the sample aliquot in the event a nonstandard aliquot is processed, field measurement results, and analytical results. These manually entered data are keypunched and read into the computer files. The computer files are audited daily, and summaries of samples not processed in pre-established normal time intervals are issued. The progress of sample analyses can also be readily determined at any time using the CRT terminal. Historic data are also maintained on magnetic tape and workload summaries are issued showing the number of samples and number of determinations per month

  9. Sample preparation of environmental samples using benzene synthesis followed by high-performance LSC

    International Nuclear Information System (INIS)

    Filippis, S. De; Noakes, J.E.

    1991-01-01

    Liquid scintillation counting (LSC) techniques have been widely employed as the detection method for determining environmental levels of tritium and 14 C. Since anthropogenic and nonanthropogenic inputs to the environment are a concern, sampling the environment surrounding a nuclear power facility or fuel reprocessing operation requires the collection of many different sample types, including agriculture products, water, biota, aquatic life, soil, and vegetation. These sample types are not suitable for the direct detection of tritium of 14 C for liquid scintillation techniques. Each sample type must be initially prepared in order to obtain the carbon or hydrogen component of interest and present this in a chemical form that is compatible with common chemicals used in scintillation counting applications. Converting the sample of interest to chemically pure benzene as a sample preparation technique has been widely accepted for processing samples for radiocarbon age-dating applications. The synthesized benzene is composed of the carbon or hydrogen atoms from the original sample and is ideal as a solvent for LSC with excellent photo-optical properties. Benzene synthesis followed by low-background scintillation counting can be applied to the preparation and measurement of environmental samples yielding good detection sensitivities, high radionuclide counting efficiency, and shorter preparation time. The method of benzene synthesis provides a unique approach to the preparation of a wide variety of environmental sample types using similar chemistry for all samples

  10. Analysis of the research sample collections of Uppsala biobank.

    Science.gov (United States)

    Engelmark, Malin T; Beskow, Anna H

    2014-10-01

    Uppsala Biobank is the joint and only biobank organization of the two principals, Uppsala University and Uppsala University Hospital. Biobanks are required to have updated registries on sample collection composition and management in order to fulfill legal regulations. We report here the results from the first comprehensive and overall analysis of the 131 research sample collections organized in the biobank. The results show that the median of the number of samples in the collections was 700 and that the number of samples varied from less than 500 to over one million. Blood samples, such as whole blood, serum, and plasma, were included in the vast majority, 84.0%, of the research sample collections. Also, as much as 95.5% of the newly collected samples within healthcare included blood samples, which further supports the concept that blood samples have fundamental importance for medical research. Tissue samples were also commonly used and occurred in 39.7% of the research sample collections, often combined with other types of samples. In total, 96.9% of the 131 sample collections included samples collected for healthcare, showing the importance of healthcare as a research infrastructure. Of the collections that had accessed existing samples from healthcare, as much as 96.3% included tissue samples from the Department of Pathology, which shows the importance of pathology samples as a resource for medical research. Analysis of different research areas shows that the most common of known public health diseases are covered. Collections that had generated the most publications, up to over 300, contained a large number of samples collected systematically and repeatedly over many years. More knowledge about existing biobank materials, together with public registries on sample collections, will support research collaborations, improve transparency, and bring us closer to the goals of biobanks, which is to save and prolong human lives and improve health and quality of life.

  11. TECHNIQUES WITH POTENTIAL FOR HANDLING ENVIRONMENTAL SAMPLES IN CAPILLARY ELECTROPHORESIS

    Science.gov (United States)

    An assessment of the methods for handling environmental samples prior to capillary electrophoresis (CE) is presented for both aqueous and solid matrices. Sample handling in environmental analyses is the subject of ongoing research at the Environmental Protection Agency's National...

  12. Fast egg collection method greatly improves randomness of egg sampling in Drosophila melanogaster

    DEFF Research Database (Denmark)

    Schou, Mads Fristrup

    2013-01-01

    When obtaining samples for population genetic studies, it is essential that the sampling is random. For Drosophila, one of the crucial steps in sampling experimental flies is the collection of eggs. Here an egg collection method is presented, which randomizes the eggs in a water column...... and diminishes environmental variance. This method was compared with a traditional egg collection method where eggs are collected directly from the medium. Within each method the observed and expected standard deviations of egg-to-adult viability were compared, whereby the difference in the randomness...... and to obtain a representative collection of genotypes, the method presented here is strongly recommended when collecting eggs from Drosophila....

  13. Intrepretation of work area and environmental sampling

    International Nuclear Information System (INIS)

    Ritter, P.D.; Alvarez, J.L.; Novick, V.J.

    1985-01-01

    Meaningful interpretation of widely variable airborne contamination measurements is a difficult problem. Exposure limits, action levels, etc., are rigid interpretations of inherently variable environmental or workplace conditions, and are useful for control and regulatory compliance evaluations. Such limits force actions to reduce contamination, but have limited usefulness as benchmarks for evaluating isolated or nonrepresentative measurements. This paper deals with interpretation of exposure based on nonrepresentative sampling. The use of hard limits for interpreting measurements of legal record simplifies judgment during cursory audits; more aggressive questioning of the validity of these records may effectively invalidate them in a courtroom situation

  14. Environmental monitoring master sampling schedule: January--December 1989

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1989-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1989 for the Surface and Ground-Water Environmental Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. This schedule includes routine ground-water sampling performed by PNL for Westinghouse Hanford Company, but does not include samples that may be collected in 1989 to support special studies or special contractor projects, or for quality control. The sampling schedule for Site-wide chemical monitoring is not included here, because it varies each quarter as needed, based on past results and operating needs. This schedule does not include Resource Conservation and Recovery Act ground-water sampling performed by PNL for Hanford Site contractors, nor does it include sampling that may be done by other DOE Hanford contractors

  15. Determination of strontium-90 in the environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Perveen, N.; Aziz, A.

    1979-01-01

    Strontium-90 a bone seeking radionuclide and a long lived beta emitter is one of the toxic radionuclides detected in the environment arising mainly from the fall out from nuclear detonations. Its concentration in various environmental media such as air, precipitation, surface water, vegetables and other items of diet was measured. This report describes the method of collection, treatment and radiochemical analyses of environmental samples for the determination of Sr-90. The levels of Sr-90 concentration in these media are also recorded. (authors)

  16. Fallout Concentration Various Environmental Samples in Indonesia

    International Nuclear Information System (INIS)

    Sutarman

    2001-01-01

    The testing of nuclear weapons have been carried out by the advanced countries, such as United States, Russian Federation, United Kingdom, France, China, India and Pakistan, since about 1945 until 1998. Nuclear weapons tests were conducted at various locations, on and above the earth's surface or underground or on and under the ocean's surface. Nuclear explosions caused the radionuclides of fission product, such as 131 l, 89 Sr, 90 Sr, 134 Cs, 137 Cs, and 239 Pu released to the atmospheric layer. In the atmospheric layer, the long-lived radionuclides, i.e, 90 Sr dan 137 Cs will be distributed into the environment as the fallout radionuclides, and deposited in the various environmental samples (soil, water, and biota). In general, at several locations in Indonesia the 90 Sr and 137 Cs in the various environmental samples still can be detected. The data of measurement results of 90 Sr and 137 Cs concentrations were generally lower than that from some countries in the northern hemisphere. (author)

  17. Compendium of Environmental Sustainability Indicator Collections: Complete Collection, Version 1.1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Compendium of Environmental Sustainability Indicator Collections, Version 1.1 contains 426 indicators for 239 countries from five major environmental...

  18. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2006

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2006-01-27

    This document contains the calendar year 2006 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2006 in which case the anticipated year for collection is provided. The project document package (PDP) for Surface Environmental Surveillance contains the milestone control log for the issuing of CY06 Environmental Surveillance Master Sampling Schedule WBS 4.2.3.21.3.03, milestone: RL00430306 (4830106-12).

  19. Environmental monitoring master sampling schedule, January--December 1990

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1990-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1990 for the Environment Surveillance and Ground-Water Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This schedule includes ground-water sampling performed by PNL for environmental surveillance of the Hanford Site.

  20. Screening of IAEA environmental samples for fissile material content

    International Nuclear Information System (INIS)

    Hembree, Doyle M. Jr.; Carter, Joel A.; Devault, Gerald L.; Whitaker, J. Michael; Glasgow, David

    2001-01-01

    neutrons' because they are emitted after a brief decay period following irradiation. Counting these delayed neutrons provides a simple method for determining the total fissile content in the sample. Neutron activation analysis is a nuclear technique, which means that the chemical bonding environment of a fissile atom has no effect on the measurement process. Therefore, NAA is virtually immune to the 'matrix' effects that complicate other methods. As a result, environmental samples such as pine needles, water, soil, sediments, or swipes can all be rapidly analyzed with little or no sample preparation. All of the sources of error in the NAA-delayed neutron counting experiment are known and can be accounted for. In addition, the method is nondestructive and does not require the use of a blank measurement. The neutrons counted as a result of 239 Pu fission cannot be easily discriminated from those arising from 235 U. Therefore, the delayed neutron method proposed for sample screening will provide total fissile content; not the quantities of individual radionuclides. However, for most IAEA samples, it can be assumed that uranium is the predominant fissile material, and the method can be usefully employed for screening using this assumption (data collected from a large number of environmental samples supports this contention). The method is fast (∼5 minutes per sample), very sensitive (3-10 pg 235 U), and very accurate. An initial assessment of the NAA method was conducted using 35 swipe samples. The uranium results using thermal ionization mass spectrometry (TIMS) ranged from less than blank values to 332 ng/sample. The comparison of results between TIMS and NAA was quite favorable; the average percent difference between the two methods for the 35 samples was less than 5%. The accuracy, large dynamic range, speed, and low cost of the NAA-DN technique make the method an excellent choice for properly screening environmental samples. (author)

  1. Environmental sample accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-01-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an online disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished using computer-generated schedules, bottle labels, and output/ input cards. A printed card is issued for the collecting, analyzing, and counting of each scheduled sample. The card also contains information for the personnel who are to perform the work, e.g., sample location, aliquot to be processed, and procedure to be used. Manual entries are made on the card when each step in the process is completed. Additional pertinent data such as the reason a sample is not collected, the need for a nonstandard aliquot, and field measurement results are keypunched and then read into the computer files as required. The computer files are audited daily and summaries showing samples not processed in pre-established normal schedules are provided. The progress of sample analyses is readily determined at any time using the CRT terminal. Historic data are maintained on magnetic tape, and workload summaries showing the number of samples and number of determinations per month are issued. (author)

  2. Measurements of plutonium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    D' Alberti, F; Risposi, L [Instituto di Fisica Applicata, University of Milan, Milan (Italy)

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961.

  3. Measurements of plutonium in environmental samples

    International Nuclear Information System (INIS)

    D'Alberti, F.; Risposi, L.

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961

  4. Neutron activation analysis for environmental sample in Thailand

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Nouchpramool, Sunun; Bunprapob, Supamatthree; Sumitra, Tatchai

    2003-01-01

    Neutron Activation Analysis has been applied for the trace elements analysis in environmental samples. Thirty three samples of airborne particulate were collected every week at Ongkharak Nuclear Research Center (ONRC) during the period of June 1998 to March 1999. The Ti, I, Mg, Na, V, K, Cl, Al, Mn, Ca, As, Sm, Sb, Br, La, Ce, Th, Cr, Cs, Sc, Rb, Fe, Zn and Co were analyzed by Neutron Activation Analysis utilizing 2 MW TRIGA MARK III research reactor. The certified reference materials 1632a and 1633a from National Bureau of Standard were select as standard. (author)

  5. Does environmental data collection need statistics?

    NARCIS (Netherlands)

    Pulles, M.P.J.

    1998-01-01

    The term 'statistics' with reference to environmental science and policymaking might mean different things: the development of statistical methodology, the methodology developed by statisticians to interpret and analyse such data, or the statistical data that are needed to understand environmental

  6. The development of a Martian atmospheric Sample collection canister

    Science.gov (United States)

    Kulczycki, E.; Galey, C.; Kennedy, B.; Budney, C.; Bame, D.; Van Schilfgaarde, R.; Aisen, N.; Townsend, J.; Younse, P.; Piacentine, J.

    The collection of an atmospheric sample from Mars would provide significant insight to the understanding of the elemental composition and sub-surface out-gassing rates of noble gases. A team of engineers at the Jet Propulsion Laboratory (JPL), California Institute of Technology have developed an atmospheric sample collection canister for Martian application. The engineering strategy has two basic elements: first, to collect two separately sealed 50 cubic centimeter unpressurized atmospheric samples with minimal sensing and actuation in a self contained pressure vessel; and second, to package this atmospheric sample canister in such a way that it can be easily integrated into the orbiting sample capsule for collection and return to Earth. Sample collection and integrity are demonstrated by emulating the atmospheric collection portion of the Mars Sample Return mission on a compressed timeline. The test results achieved by varying the pressure inside of a thermal vacuum chamber while opening and closing the valve on the sample canister at Mars ambient pressure. A commercial off-the-shelf medical grade micro-valve is utilized in the first iteration of this design to enable rapid testing of the system. The valve has been independently leak tested at JPL to quantify and separate the leak rates associated with the canister. The results are factored in to an overall system design that quantifies mass, power, and sensing requirements for a Martian atmospheric Sample Collection (MASC) canister as outlined in the Mars Sample Return mission profile. Qualitative results include the selection of materials to minimize sample contamination, preliminary science requirements, priorities in sample composition, flight valve selection criteria, a storyboard from sample collection to loading in the orbiting sample capsule, and contributions to maintaining “ Earth” clean exterior surfaces on the orbiting sample capsule.

  7. Artificial radioactivity in the environmental samples as IAEA reference materials

    International Nuclear Information System (INIS)

    Salagean, M.; Pantelica, A.

    1998-01-01

    . Uncontaminated by nuclear activities: IAEA-327, Podsolic soil collected in 1990 from the Moscow region and considered uncontaminated by radionuclides of the Chernobyl accident or by other nuclear activities. The results obtained by our laboratory are in good agreement with the certified IAEA data. Generally, the concentration of the artificial radionuclides in the investigated samples is higher than that expected from the influence of global fallout in the intercomparison materials distributed before Chernobyl accident. Concerning the nature of these investigated IAEA reference materials, very high values for the concentration levels of cesium radionuclides especially in IAEA-373 (grass) and IAEA-375 (soil) samples collected in the vicinity of Chernobyl Power Station after the nuclear accident in 1986 were found. High levels of radioactivities for the artificial radionuclides were also determined in the samples collected in the neighbourhood of the nuclear installations, especially in marine sediment (IAEA-135). It is of interest to point out the high concentration of cesium radionuclides in IAEA-300 sediment collected in 1992 in the Baltic Sea in comparison with the IAEA-306 sediment collected also in the Baltic Sea in 1986. It seems to be an increase of the Baltic Sea artificial radioactivity by accumulation in time. Marine sediment constitutes an important component of marine ecosystem since it represents the final sink for any releases of wastes into the sea. These certified radioactive materials are very useful to all laboratories engaged in the radioactive pollution investigations on environmental samples. (authors)

  8. Stability of metal ions in aqueous environmental samples

    International Nuclear Information System (INIS)

    Rattonetti, A.

    1976-01-01

    The time lapse between the collection of aqueous environmental samples and the analysis affects the original ionic concentration. Studies have proven the nonionic species in a water sample have more of an effect on the veracity of an analysis than the ''container wall'' effect, and that adjustment to a pH of 2 at sample collection time is a ''Pyrrhic victory.'' Lead, for example, will commonly increase an order of magnitude when unfiltered samples are adjusted to a pH of 2 upon collection. This effect is greatest when elemental ions are present in the ng ml -1 range and lessens as the original ionic concentration increases. Data are presented that behooves filtration of stream water and rainwater samples prior to any acidification step. The need to acidify the resulting filtrate is also discussed. Lithium, sodium, potassium, cesium, magnesium, calcium, strontium, manganese, iron, copper, silver, zinc, cadmium, aluminum, indium, and lead are examined. The insoluble phase retained on the filter can be digested with acid and also analyzed. The separate analysis of the filtrate and filter will give a true representation of the occurrence of these metals in nature. Flame and flameless atomic aborption and emission are used to perform the trace analyses

  9. Assessing human error during collecting a hydrocarbon sample of ...

    African Journals Online (AJOL)

    This paper reports the assessment method of the hydrocarbon sample collection standard operation procedure (SOP) using THERP. The Performance Shaping Factors (PSF) from THERP analyzed and assessed the human errors during collecting a hydrocarbon sample of a petrochemical refinery plant. Twenty-two ...

  10. Compendium of Environmental Sustainability Indicator Collections: 2005 Environmental Sustainability Index (ESI)

    Data.gov (United States)

    National Aeronautics and Space Administration — The 2005 Environmental Sustainability Index (ESI) portion of the Compendium of Environmental Sustainability Indicators Collection contains 103 variables for 146...

  11. Compendium of Environmental Sustainability Indicator Collections: 2004 Environmental Vulnerability Index (EVI)

    Data.gov (United States)

    National Aeronautics and Space Administration — The 2004 Environmental Vulnerability Index (EVI) portion of the Compendium of Environmental Sustainability Indicator Collections contains 111 variables for 235...

  12. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Laboratory Management Division of the DOE. Methods are prepared for entry into DOE Methods as chapter editors, together with DOE and other participants in this program, identify analytical and sampling method needs. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types. open-quotes Draftclose quotes or open-quotes Verified.close quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations

  13. Environmental Sampling, Monitoring and Site Assessment Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Quality Data Asset includes all current and historical data on environmental quality with regard to the presence of radiological contamination of all kinds regulated...

  14. Program of environmental and bio monitoring sampling

    International Nuclear Information System (INIS)

    Fernandez, H.

    2012-01-01

    This presentation is about the importance of the biological signs to determine the environmental features characteristics.The low level of taxonomic resolution and the environmental perturbation is determined by the bio monitoring techniques

  15. Radioactivity in Soil Samples Collected in Southern Serbia

    International Nuclear Information System (INIS)

    Jankovic, M.; Nikolic, J.; Pantelic, G.; Rajacic, M.; Sarap, N.; Todorovic, D.

    2013-01-01

    In the attack on the Federal Republic of Yugoslavia (the focus effect was of Kosovo and Metohija and southern Serbia) in 1999, NATO forces used ammunition containing depleted uranium. Cleaning action of depleted uranium was performed by Radiation and Environmental Protection Department of the Vinca Institute of Nuclear Science, during 2002?2007 at locations: Pljackovica, Bratoselce, Borovac and Reljan. At all locations underwent detailed dosimetric screening and decontamination was performed. Because of the loose soil, DU projectils were found to a depth of 1 m. Found missiles, contaminated soil and radioactive material has been collected and stored on radioactive waste. After cleaning the ground is leveled and another dosimetric prospecting was performed. Monitoring of radioactivity in southern Serbia included determination of gamma emitters as well as determination of gross alpha and beta activities in soil, water and plant. Sampling was carried out at Pljackovica, Borovac, Bratoselce and Reljan in July 2011. This paper presents only the results of measurement of gamma emitters in soil samples and showed the presence of natural radionuclides: 226Ra, 232Th, 40K, 235U, 238U and the produced radionuclide 137Cs (from the Chernobyl accident). Also, the ratio between the 235U and 238U is given. In order to evaluate the radiological hazard of the natural radioactivity, the radium equivalent activity, the gamma-absorbed dose rate and the external hazard index have been calculated. (author)

  16. Experience with environmental sampling at gas centrifuge enrichment plants

    International Nuclear Information System (INIS)

    Ekenstam, G. af; Bush, W.; Janov, J.; Kuhn, E.; Ryjinski, M.

    2001-01-01

    Environmental sampling has been used routinely by the IAEA since 1996 after the IAEA Board of Governors approved it in March 1995 as a new technique to strengthen safeguards and improve efficiency. In enrichment plants it is used to confirm that there has been no production of highly enriched uranium (HEU), or production of uranium at above the declared enrichment. The use of environmental sampling is based on the assumption that every process, no matter how leak tight, will release small amounts of process material to the environment. Even though these releases of nuclear material are extremely small in gas centrifuge enrichment plants, and well below levels of concern from a health physics and safety standpoint, they are detectable and their analysis provides an indication of the enrichment of the material that has been processed in the plant. The environmental samples at enrichment plants are collected by swiping selected areas of the plant with squares of cotton cloth (10x10 cm) from sampling kits prepared in ultra clean condition. The squares of cotton cloth sealed in plastic bags are sent for analysis to the Network Analytical Laboratories. The analysis includes the measurement of the uranium isotopic composition in uranium-containing particles by Thermal lonization Mass Spectroscopy (TIMS) or Secondary ION Mass Spectroscopy (SIMS). Since the implementation of environmental sampling, swipes have been collected from 240 sampling points at three gas centrifuge plants of URENCO, which have a total throughput of more than 8,000 tonnes of uranium per year. The particle analysis results generally reflected the known operational history of the plants and confirmed that they had only been operated to produce uranium with enrichment less than 5% 235 U. The information about the content of the minor isotopes 234 U and 236 U also indicates that depleted and recycled uranium were sometimes used as feed materials in some plants. An example is given of the TIMS particle

  17. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, open-quotes Draftclose quotes or open-quotes Verifiedclose quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy

  18. DOE methods for evaluating environmental and waste management samples

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K. [eds.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  19. Characterization Of Core Sample Collected From The Saltstone Disposal Facility

    International Nuclear Information System (INIS)

    Cozzi, A.; Duncan, A.

    2010-01-01

    During the month of September 2008, grout core samples were collected from the Saltstone Disposal Facility, Vault 4, cell E. This grout was placed during processing campaigns in December 2007 from Deliquification, Dissolution and Adjustment Batch 2 salt solution. The 4QCY07 Waste Acceptance Criteria sample collected on 11/16/07 represents the salt solution in the core samples. Core samples were retrieved to initiate the historical database of properties of emplaced Saltstone and to demonstrate the correlation between field collected and laboratory prepared samples. Three samples were collected from three different locations. Samples were collected using a two-inch diameter concrete coring bit. In April 2009, the core samples were removed from the evacuated sample container, inspected, transferred to PVC containers, and backfilled with nitrogen. Samples furthest from the wall were the most intact cylindrically shaped cored samples. The shade of the core samples darkened as the depth of coring increased. Based on the visual inspection, sample 3-3 was selected for all subsequent analysis. The density and porosity of the Vault 4 core sample, 1.90 g/cm 3 and 59.90% respectively, were comparable to values achieved for laboratory prepared samples. X-ray diffraction analysis identified phases consistent with the expectations for hydrated Saltstone. Microscopic analysis revealed morphology features characteristic of cementitious materials with fly ash and calcium silicate hydrate gel. When taken together, the results of the density, porosity, x-ray diffraction analysis and microscopic analysis support the conclusion that the Vault 4, Cell E core sample is representative of the expected waste form.

  20. Modified electrode voltammetric sensors for trace metals in environmental samples

    Directory of Open Access Journals (Sweden)

    Brett Christopher M.A.

    2000-01-01

    Full Text Available Nafion-modified mercury thin film electrodes have been investigated for the analysis of trace metals in environmental samples of waters and effluent by batch injection analysis with square wave anodic stripping voltammetry. The method, involving injection over the detector electrode of untreated samples of volume of the order of 50 microlitres has fast response, blocking and fouling of the electrode is minimum as shown by studies with surface-active components. Comparison is made between glassy carbon substrate electrodes and carbon fibre microelectrode array substrates, the latter leading to a small sensitivity enhancement. Application to analysis of river water and industrial effluent for labile zinc, cadmium, lead and copper ions is demonstrated in collected samples and after acid digestion.

  1. Guidance for establishment and implementation of a national sample management program in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. Therefore the NSMP's primary role is to coordinate and function as a central repository for information collected from the FSMPs. An additional role of the NSMP is to monitor trends in data collected from the FSMPs over time and across sites and laboratories. Tracking these trends will allow identification of potential problems in the sampling and analysis process

  2. Collecting Ground Samples for Balloon-Borne Instruments

    Science.gov (United States)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq

    2009-01-01

    A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

  3. Evaluating the reproducibility of environmental radioactivity monitoring data through replicate sample analysis

    International Nuclear Information System (INIS)

    Lindeken, C.L.; White, J.H.; Silver, W.J.

    1978-01-01

    At the Lawrence Livermore Laboratory, about 10% of the sampling effort in the environmental monitoring program represents replicate sample collection. Replication of field samples was initiated as part of the quality assurance program for environmental monitoring to determine the reproducibility of environmental measurements. In the laboratory these replicates are processed along with routine samples. As all components of variance are included in analysis of such field samples, comparison of the analytical data from replicate analyses provides a basis for estimating the overall reproducibility of the measurements. The replication study indicates that the reproducibility of environmental radioactivity monitoring data is subject to considerably more variability than is indicated by the accompanying counting errors. The data are also compared with analyses of duplicate aliquots from a well mixed sample or with duplicate aliquots of samples with known radionuclide content. These comparisons show that most of the variability is associated with the collection and preparation of the sample rather than with the analytical procedures

  4. Fieldwork and catalogue of samples collected in Polan, September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Poulsen, N.; Drewniak, A.; Glowniak, E.; Ineson, J.; Matyja, B.A.; Merta, T.; Wierzbowski, A.

    1995-12-31

    This report lists the collection of samples taken during the field work of the EFP-95 Project, named `The Polish Middle to Late Jurassic Epicratonic basin, stratigraphy, facies and basin history` (short title: Jurrasic basin study, Poland) in Poland, August 7-20, 1995. The samples were collected for palynological studies, and/or sedimentaological studies, and/or source rock studies, and/or reservoir rock characteristics. Prepared samples (slides etc.) are stored in the collections of the GEUS, and remaining rock-material at the store of the GEUS. Field work with collection of samples for palynological studies has been carried earlier in 1988 and at the Oxfordian and Kimmeridgian Joint Working Groups Meeting 1992. (au)

  5. A comparison of some radionuclide contents in environmental samples

    International Nuclear Information System (INIS)

    Shiraishi, Kunio; Muramatsu, Yasuyuki; Nakajima, Toshiyuki; Yamamoto, Masayoshi; Los, I.P.; Kamarikov, I.Yu.; Buzinny, M.G.

    1992-01-01

    Global contamination by radionuclides was likely induced through the Chernobyl nuclear accident in 1986. Environmental samples such as fish, milk, total diet samples etc., collected in Kiev, in the vicinity of Chernobyl, and Mito city, Japan, were analyzed for six selected radionuclides. After samples were dry-ashed, radioactivities of Cs-137, Cs-134, K-40, Co-60, and Mn-54 were determined by gamma-ray spectroscopy with a germanium detector. Strontium-90 was determined by low-background beta-spectrometry after chemical separations by fuming nitric acid. Concentrations of radioactivities in the Kiev samples, in the vicinity of the Chernobyl, are shown below. For comparison, values obtained in Japan, including literature values, are shown in parentheses. Radioactivities in airborne dust were: Sr-90, 63 mBq/m 3 (0.001-0.1); Cs-137, 26 mBg/m 3 (0.001-1); Cs-134, 4 mBq/m 3 ; Co-60, 4 mBq/m 3 ; Mn-54, 2 mBq/m 3 . Radioactivities of milk were as follows; Sr-90, 0.25-1.2 Bq/liter (0.01-0.1); Cs-137, 6-77 Bq/liter (0.01-1); Cs-134, 2-8 Bq/liter. Radioactivities of Sr-90 and Cs-137 for fish (carp), were found to be 3-75 Bq/kg-fresh (0.76-0.98) and 46-2130 Bq/kg-fresh (<0.8), respectively. It was observed that the daily intake of Sr-90 and Cs-137 were 0.25 Bq (0.1) and 0.43 Bq (0.1) per person, respectively. Due to the small number of samples analyzed it is premature to draw a firm conclusion from this study. However, the levels of radionuclides in environmental samples were found to differ between Kiev and Mito with wide ranges depending on the samples. (author)

  6. Radiochemical verification and validation in the environmental data collection process

    International Nuclear Information System (INIS)

    Rosano-Reece, D.; Bottrell, D.; Bath, R.J.

    1994-01-01

    A credible and cost effective environmental data collection process should produce analytical data which meets regulatory and program specific requirements. Analytical data, which support the sampling and analysis activities at hazardous waste sites, undergo verification and independent validation before the data are submitted to regulators. Understanding the difference between verification and validation and their respective roles in the sampling and analysis process is critical to the effectiveness of a program. Verification is deciding whether the measurement data obtained are what was requested. The verification process determines whether all the requirements were met. Validation is more complicated than verification. It attempts to assess the impacts on data use, especially when requirements are not met. Validation becomes part of the decision-making process. Radiochemical data consists of a sample result with an associated error. Therefore, radiochemical validation is different and more quantitative than is currently possible for the validation of hazardous chemical data. Radiochemical data include both results and uncertainty that can be statistically compared to identify significance of differences in a more technically defensible manner. Radiochemical validation makes decisions about analyte identification, detection, and uncertainty for a batch of data. The process focuses on the variability of the data in the context of the decision to be made. The objectives of this paper are to present radiochemical verification and validation for environmental data and to distinguish the differences between the two operations

  7. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2010

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2010-01-08

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford Site environs per regulatory requirements. This document contains the calendar year 2010 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2010, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2010.

  8. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2009

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2009-01-20

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1 and DOE Order 5400.5. This document contains the calendar year 2009 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2009, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2009.

  9. The Apollo lunar samples collection analysis and results

    CERN Document Server

    Young, Anthony

    2017-01-01

    This book focuses on the specific mission planning for lunar sample collection, the equipment used, and the analysis and findings concerning the samples at the Lunar Receiving Laboratory in Texas. Anthony Young documents the collection of Apollo samples for the first time for readers of all backgrounds, and includes interviews with many of those involved in planning and analyzing the samples. NASA contracted with the U.S. Geologic Survey to perform classroom and field training of the Apollo astronauts. NASA’s Geology Group within the Manned Spacecraft Center in Houston, Texas, helped to establish the goals of sample collection, as well as the design of sample collection tools, bags, and storage containers. In this book, detailed descriptions are given on the design of the lunar sampling tools, the Modular Experiment Transporter used on Apollo 14, and the specific areas of the Lunar Rover vehicle used for the Apollo 15, 16, and 17 missions, which carried the sampling tools, bags, and other related equipment ...

  10. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  11. Deepwater Horizon MC252 analytical data from the Environmental Response Management Application (ERMA) containing sediment chemistry data, tissue chemistry data, environmental quality and monitoring data, sample pre/post oiling analysis data, and Total Polycyclic Aromatic Hydrocarbon (TPAH) contaminants chemistry data from samples collected from 2010-03-07 to 2013-08-28 in the Northern Gulf of Mexico (NCEI Accession 0163796)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This Archival Information Package (AIP) contains Environmental Resource Management Application (ERMA) GIS layers that represent nearshore tissue and sediment...

  12. Radiation Target Area Sample Environmental Chamber (RTASEC), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Payload Systems Inc. proposes the Radiation Target Area Sample Environmental Chamber (RTASEC) as an innovative approach enabling radiobiologists to investigate the...

  13. Sample collection and sample analysis plan in support of the 105-C/190-C concrete and soil sampling activities

    International Nuclear Information System (INIS)

    Marske, S.G.

    1996-07-01

    This sampling and analysis plan describes the sample collection and sample analysis in support of the 105-C water tunnels and 190-C main pumphouse concrete and soil sampling activities. These analytical data will be used to identify the radiological contamination and presence of hazardous materials to support the decontamination and disposal activities

  14. Collective behaviour, uncertainty and environmental change.

    Science.gov (United States)

    Bentley, R Alexander; O'Brien, Michael J

    2015-11-28

    A central aspect of cultural evolutionary theory concerns how human groups respond to environmental change. Although we are painting with a broad brush, it is fair to say that prior to the twenty-first century, adaptation often happened gradually over multiple human generations, through a combination of individual and social learning, cumulative cultural evolution and demographic shifts. The result was a generally resilient and sustainable population. In the twenty-first century, however, considerable change happens within small portions of a human generation, on a vastly larger range of geographical and population scales and involving a greater degree of horizontal learning. As a way of gauging the complexity of societal response to environmental change in a globalized future, we discuss several theoretical tools for understanding how human groups adapt to uncertainty. We use our analysis to estimate the limits of predictability of future societal change, in the belief that knowing when to hedge bets is better than relying on a false sense of predictability. © 2015 The Author(s).

  15. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    Energy Technology Data Exchange (ETDEWEB)

    Marberry, Hugh [SRNS Savannah River Site 730-4B Room 3043 Aiken, SC 29808 (United States); Moore, Winston [SRNS Savannah River Site 735B Room 116 Aiken, SC 29808 (United States)

    2013-07-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

  16. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    International Nuclear Information System (INIS)

    Marberry, Hugh; Moore, Winston

    2013-01-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

  17. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    OpenAIRE

    Helena Prosen

    2014-01-01

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several...

  18. Curating NASA's Past, Present, and Future Astromaterial Sample Collections

    Science.gov (United States)

    Zeigler, R. A.; Allton, J. H.; Evans, C. A.; Fries, M. D.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC

  19. Collection and control of tritium bioassay samples at Pantex

    International Nuclear Information System (INIS)

    Fairrow, N.L.; Ivie, W.E.

    1992-01-01

    Pantex is the final assembly/disassembly point for US nuclear weapons. The Pantex internal dosimetry section monitors radiation workers once a month for tritium exposure. In order to manage collection and control of the bioassay specimens efficiently, a bar code system for collection of samples was developed and implemented to speed up the process and decrease the number of errors probable when transferring data. In the past, all the bioassay data from samples were entered manually into a computer database. Transferring the bioassay data from the liquid scintillation counter to each individual's dosimetry record required as much as two weeks of concentrated effort

  20. Determination of radium-226 in environmental samples

    International Nuclear Information System (INIS)

    Powers, R.P.; Turnage, N.E.; Kanipe, L.G.

    1980-01-01

    The analysis of soil and water samples for 226 Ra by gamma spectrometry with a Ge(Li) detector was compared with that by radiochemical separation followed by 222 Rn de-emanation. Lower limits of detection (LLD) for 226 Ra were calculated for the two analytical techniques. The Ge(Li) system was found to have an LLD for soil comparable to that calculated for the de-emanation procedure, but the Ge(Li) system was found to have a significantly higher LLD for water samples. Cost analysis indicated that the cost of 222 Ra determination with a Ge(Li) system can be less than with the de-emanation procedure if the Ge(Li) system can perform at least one other isotopic anaysis per sample

  1. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2008-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1, "Environmental Protection Program," and DOE Order 5400.5, "Radiation Protection of the Public and the Environment." The environmental surveillance sampling design is described in the "Hanford Site Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office." This document contains the calendar year 2008 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2008, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2008.

  2. Detection of iodine-129 in some environmental samples

    International Nuclear Information System (INIS)

    Ikeda, Nagao

    1981-01-01

    The recent accumulation of the long-lived isotope of iodine, 129 I, which is released in environment by the peaceful use of nuclear energy or nuclear test explosion is becoming important in the view point of the internal exposure by the low level radiation. The studies on the detection of determination of 129 I in environmental samples so far published are still very few. The authors tried to detect 129 I in some Japanese seaweeds and soil samples with the aid of the activation method by using the nuclear reaction of 129 I(n, #betta#) 130 I. The samples analysed in this work are tangle (Laminaria japonica) for daily food grown in Hidaka, Hokkaido and uncultivated soil collected in Tokai, Ibaraki Pref. As the #betta#-ray peak indicator for 130 I, cesium oxide and the aged radioisotope product of 131 I are also subjected to the neutron irradiation. From cesium oxide, 130 I is formed by the reaction of 133 Cs(n, α) 130 I. An aged vial of the 131 I product is expected to contain very minute amounts of 129 I which is also produced both by the fission of uranium and neutron capture reaction of tellurium followed by #betta# - -decay. The #betta#-ray spectra for the soil sample, cesium oxide and the aged 131 I vial are shown in Fig. 1. No appreciable peak was found for the seaweeds sample. In the #betta#-ray spectra for irradiated cesium oxide and the aged 131 I vial, several typical peaks for 130 I were observed. By comparing with these peaks, several small peaks which appear at around 418, 536 and 739 keV in the soil sample can be attributed to those of 130 I. The 129 I content in the soil sample is roughly estimated to be 2 x 10 - 10 Bq/g. (author)

  3. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1993-03-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others

  4. DOE methods for evaluating environmental and waste management samples.

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K [eds.; Pacific Northwest Lab., Richland, WA (United States)

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  5. Characteristics of the samples in the FNG fission deposit collection

    Energy Technology Data Exchange (ETDEWEB)

    Meadows, J.W.

    1990-12-01

    Information concerning the samples in the Fast Neutron Generator (FNG) Group's fission deposit collection has been assembled. This includes the physical dimensions, isotopic analyses, half-lives, alpha emission rates specific activities and deposit weights. 10 refs., 9 figs., 5 tabs.

  6. Is there an environmentally optimal separate collection rate?

    Science.gov (United States)

    Haupt, M; Waser, E; Würmli, J C; Hellweg, S

    2018-04-20

    Material recycling often leads to environmental benefits when compared to thermal treatments or landfilling and is therefore positioned in the waste hierarchy as the third priority after waste prevention and reuse. To assess the environmental impacts of recycling and the related substitution of primary material, linear steady-state models of physical flows are typically used. In reality, the environmental burdens of collection and recycling are likely to be a non-linear function of the collection rate. This short communication aims at raising awareness of the non-linear effects in separate collection systems and presents the first non-linear quantitative model for PET bottle recycling. The influence of collection rates on the material quality and the transport network is analyzed based on the data collected from industrial partners. The results highlight that in the present Swiss recycling system a very high collection rate close to 100% yields optimum environmental benefits with respect to global warming. The empirical data, however, provided indications for a decrease in the marginal environmental benefit of recycling. This can be seen as an indication that tipping points may exist for other recycling systems, in which the environmental benefits from substituting primary materials are less pronounced than they are for PET. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. New trends in sample preparation techniques for environmental analysis.

    Science.gov (United States)

    Ribeiro, Cláudia; Ribeiro, Ana Rita; Maia, Alexandra S; Gonçalves, Virgínia M F; Tiritan, Maria Elizabeth

    2014-01-01

    Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).

  8. Analysis of mercury in environmental samples

    International Nuclear Information System (INIS)

    Schoester, F.S.

    1992-01-01

    The possibility to determine mercury in sub-ppm levels in biological samples has been studied through neutron activation analysis , using as standards aliquots of mercury nitrate solution, deposited on treated cellulose with thio acetamide and ammonia. Sample and standards were irradiated simultaneously in quartz ampoules during 8 hours at a flux of 5 x 10 13 n/cm 2 s and were counted in a hyper pure germanium detector after 4 weeks of decay. Corrections were made for the interference of 75 Se in the 279 keV photopeak used in the determination. The results obtained for the reference materials IAEA-H-8(horse kidney), IAEA-M A-A2(fish flesh) and IAEA-M A-A-1(cope pod homogenate) were (0.91±0.07), (0.56±0.02) and (0.17±0.02) ppm, versus certified values of (0.91±0.08), (0.47±0.02) and (0.28±0.01) ppm respectively. (EMR). 54 refs., 8 app

  9. Comparison of DNA preservation methods for environmental bacterial community samples.

    Science.gov (United States)

    Gray, Michael A; Pratte, Zoe A; Kellogg, Christina A

    2013-02-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard(™), RNAlater(®), DMSO-EDTA-salt (DESS), FTA(®) cards, and FTA Elute(®) cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA(®) cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard(™), RNAlater(®), and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  10. A 'feather-trap' for collecting DNA samples from birds.

    Science.gov (United States)

    Maurer, Golo; Beck, Nadeena; Double, Michael C

    2010-01-01

    Genetic analyses of birds are usually based on DNA extracted from a blood sample. For some species, however, obtaining blood samples is difficult because they are sensitive to handling, pose a conservation or animal welfare concern, or evade capture. In such cases, feathers obtained from live birds in the wild can provide an alternative source of DNA. Here, we provide the first description and evaluation of a 'feather-trap', consisting of small strips of double-sided adhesive tape placed close to a nest with chicks, as a simple, inexpensive and minimally invasive method to collect feathers. The feather-trap was tested in tropical conditions on the Australian pheasant coucal (Centropus phasianinus). None of the 12 pairs of coucals on which the feather-trap was used abandoned the nest, and feeding rates did not differ from those of birds not exposed to a feather-trap. On average, 4.2 feathers were collected per trap over 2-5 days and, despite exposure to monsoonal rain, DNA was extracted from 71.4% of samples, albeit at low concentrations. The amount of genomic DNA extracted from each feather was sufficient to reliably genotype individuals at up to five microsatellite loci for parentage analysis. We show that a feather-trap can provide a reliable alternative for obtaining DNA in species where taking blood is difficult. It may also prove useful for collecting feather samples for other purposes, e.g. stable-isotope analysis. © 2009 Blackwell Publishing Ltd.

  11. Organically bound tritium analysis in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Baglan, N. [CEA/DAM/DIF, Arpajon (France); Kim, S.B. [AECL, Chalk River Laboratories, Chalk River, ON (Canada); Cossonnet, C. [IRSN/PRP-ENV/STEME/LMRE, Orsay (France); Croudace, I.W.; Warwick, P.E. [GAU-Radioanalytical, University of Southampton, Southampton (United Kingdom); Fournier, M. [IRSN/DG/DMQ, Fontenay-aux-Roses (France); Galeriu, D. [IFIN-HH, Horia-Hulubei, Inst. Phys. and Nucl. Eng., Bucharest (Romania); Momoshima, N. [Kyushu University, Radioisotope Ctr., Fukuoka (Japan); Ansoborlo, E. [CEA/DEN/DRCP/CETAMA, Bagnols-sur-Ceze (France)

    2015-03-15

    Organically bound tritium (OBT) has become of increased interest within the last decade, with a focus on its behaviour and also its analysis, which are important to assess tritium distribution in the environment. In contrast, there are no certified reference materials and no standard analytical method through the international organization related to OBT. In order to resolve this issue, an OBT international working group was created in May 2012. Over 20 labs from around the world participated and submitted their results for the first intercomparison exercise results on potato (Sep 2013). The samples, specially-prepared potatoes, were provided in March 2013 to each participant. Technical information and results from this first exercise are discussed here for all the labs which have realised the five replicates necessary to allow a reliable statistical treatment. The results are encouraging as the increased number of participating labs did not degrade the observed dispersion of the results for a similar activity level. Therefore, the results do not seem to depend on the analytical procedure used. From this work an optimised procedure can start to be developed to deal with OBT analysis and will guide subsequent planned OBT trials by the international group.

  12. Ash contents of foodstuff samples in environmental radioactivity analysis

    International Nuclear Information System (INIS)

    Oikawa, Shinji; Ohta, Hiroshi; Hayano, Kazuhiko; Nonaka, Nobuhiro

    2004-01-01

    Statistical data of the ash content in various environmental samples obtained from an environmental radioactivity survey project commissioned by the Japanese government of Science and Technology Agency (at present Ministry of Education, Culture, Sports, Sciences and Technology) during the past 10 years are expressed for establishing a standard of ash content in environmental samples based on radioactivity analysis. The ash content for some kinds of environmental samples such as dietary food, milk, Japanese radish, spinach, fish, green tea and potato was reviewed in the light of statistical and stochastic viewpoints. For all of the samples reviewed in this paper, the coefficient of variation varied from 4.7% for milk to 36.3% for cabbage. Dietary food and milk samples were reviewed more than 1900 and 1400 samples, respectively. Especially, ash content of dietary food depended mainly on the dietary culture reflected on the period. However it showed an almost invariant distribution within 18.7% of coefficient of variation during the past 10 years. Pretreatment of environmental samples especially ashing processes are important from the viewpoint on environmental radioactivity analysis, which is one of the especial fields in analytical chemistry. Statistical reviewed data obtained in this paper may be useful for sample preparation. (author)

  13. The importance of sound methodology in environmental DNA sampling

    Science.gov (United States)

    T. M. Wilcox; K. J. Carim; M. K. Young; K. S. McKelvey; T. W. Franklin; M. K. Schwartz

    2018-01-01

    Environmental DNA (eDNA) sampling - which enables inferences of species’ presence from genetic material in the environment - is a powerful tool for sampling rare fishes. Numerous studies have demonstrated that eDNA sampling generally provides greater probabilities of detection than traditional techniques (e.g., Thomsen et al. 2012; McKelvey et al. 2016; Valentini et al...

  14. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    Science.gov (United States)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  15. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2005

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2005-01-19

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This document contains the calendar year 2005 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project.

  17. Collection and preparation of marine samples for radionuclide analysis

    International Nuclear Information System (INIS)

    Holm, E.

    1997-01-01

    The ultimate goal of research in radioecology is to be able to predict the pathways of radioactive material in the environment and hence estimate possible doses to the population in various regions. Knowledge of levels of contamination are necessary to maintain control of operations of nuclear facilities. Correct methods of sample collection, handling and preparation are among the most important parts for a correct assessment. On basis of the final results of radionuclide concentrations, scientific, medical and political decisions are taken. (author)

  18. Collection and preparation of water samples for hydrogeochemical reconnaissance

    International Nuclear Information System (INIS)

    Baucom, E.I.; Ferguson, R.B.; Wallace, R.M.

    1977-01-01

    A method based on ion exchange and neutron activation analysis (NAA) was developed and field-tested to determine uranium over the range 0.02 to 10,000 ppb in natural water using a single procedure. Water samples are filtered in the field using a specially-designed one-liter filter apparatus pressurized to 40 psig with an inert gas. The filtered water is treated with a high purity, mixed cation-anion resin in the hydronium-hydroxide form. All ions are removed from solution under the strong driving force of the neutralization reaction. Anionic, cationic, and natural complexes of uranium can be concentrated with this method. Field tests showed greater than 95 percent recovery of 13 elements analyzed (including greater than 99 percent recovery of uranium) and greater than or equal to 90 percent recovery of 4 other elements. Uranium collected on the resin was quantitatively determined by NAA. Coefficient of variation for sampling plus analysis was less than 20 percent for samples containing more than 0.1 ppb uranium. Advantages of this method include: (1) wide dynamic range, (2) low detection limit for uranium (0.02 ppb), (3) high precision and accuracy, (4) relatively low cost, (5) high-yield recovery from low-level aqueous samples without risk of loss to containers, (6) decreased risk of significant sample contamination compared with other low-level methods, (7) production of stable samples suitable for retrievable storage, and(8) concentration of other ions that can be determined by NAA. This paper presents (1) background regarding development of procedures for sample collection and preparation, (2) results of development programs, (3) description of equipment and field procedures, and (4) preliminary conclusions regarding use of this technology for hydrogeochemical reconnaissance for uranium

  19. Guidance for establishment and implementation of field sample management programs in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. The purpose of this document is to establish the suggested scope of the FSMP activities to be performed under each Operations Office, list the drivers under which the program will operate, define terms and list references. This guidance will apply only to EM sampling and analysis activities associated with project planning, contracting, laboratory selection, sample collection, sample transportation, laboratory analysis and data management

  20. Evaluation of environmental sampling methods for detection of Salmonella enterica in a large animal veterinary hospital.

    Science.gov (United States)

    Goeman, Valerie R; Tinkler, Stacy H; Hammac, G Kenitra; Ruple, Audrey

    2018-04-01

    Environmental surveillance for Salmonella enterica can be used for early detection of contamination; thus routine sampling is an integral component of infection control programs in hospital environments. At the Purdue University Veterinary Teaching Hospital (PUVTH), the technique regularly employed in the large animal hospital for sample collection uses sterile gauze sponges for environmental sampling, which has proven labor-intensive and time-consuming. Alternative sampling methods use Swiffer brand electrostatic wipes for environmental sample collection, which are reportedly effective and efficient. It was hypothesized that use of Swiffer wipes for sample collection would be more efficient and less costly than the use of gauze sponges. A head-to-head comparison between the 2 sampling methods was conducted in the PUVTH large animal hospital and relative agreement, cost-effectiveness, and sampling efficiency were compared. There was fair agreement in culture results between the 2 sampling methods, but Swiffer wipes required less time and less physical effort to collect samples and were more cost-effective.

  1. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  2. Master schedule for CY-1984 Hanford environmental surveillance routine sampling program

    International Nuclear Information System (INIS)

    Blumer, P.J.; Price, K.R.; Eddy, P.A.; Carlile, J.M.V.

    1983-12-01

    This report provides the current schedule of data collection for the routine Hanford environmental surveillance and ground-water Monitoring Programs at the Hanford Site. The purpose is to evaluate and report the levels of radioactive and nonradioactive pollutants in the Hanford environs. The routine sampling schedule provided herein does not include samples that are planned to be collected during FY-1984 in support of special studies, special contractor support programs, or for quality control purposes

  3. Capability of environmental sampling to detect undeclared cask openings

    International Nuclear Information System (INIS)

    Beckstead, L.W.; Efurd, D.W.; Hemberger, P.H.; Abhold, M.E.; Eccleston, G.W.

    1997-01-01

    The goal of this study is to determine the signatures that would allow monitors to detect diversion of nuclear fuel (by a diverter) from a storage area such as a geological repository. Due to the complexity of operations surrounding disposal of spent nuclear fuel in a geologic repository, there are several places that a diversion of fuel could take place. After the canister that contains the fuel rods is breached, the diverter would require a hot cell to process or repackage the fuel. A reference repository and possible diversion scenarios are discussed. When a canister is breached, or during reprocessing to extract nuclear weapons material (primarily Pu), several important isotopes or signatures including tritium, 85 Kr, and 129 I are released to the surrounding environment and have the potential for analysis. Estimates of release concentrations of the key signatures from the repository under a hypothetical diversion scenario are presented and discussed. Gas analysis data collected from above-ground storage casks at Idaho National Engineering and Environmental Laboratory (INEEL) Test Area North (TAN) are included and discussed in the report. In addition, LANL participated in gas sampling of one TAN cask, the Castor V/21, in July 1997. Results of xenon analysis from the cask gas sample are presented and discussed. The importance of global fallout and recent commercial reprocessing activities and their effects on repository monitoring are discussed. Monitoring and instrumental equipment for analysis of the key signature isotopes are discussed along with limits of detection. A key factor in determining if diversion activities are in progress at a repository is the timeliness of detection and analysis of the signatures. Once a clandestine operation is suspected, analytical data should be collected as quickly as possible to support any evidence of diversion

  4. Capability of environmental sampling to detect undeclared cask openings

    Energy Technology Data Exchange (ETDEWEB)

    Beckstead, L.W.; Efurd, D.W.; Hemberger, P.H.; Abhold, M.E.; Eccleston, G.W.

    1997-12-01

    The goal of this study is to determine the signatures that would allow monitors to detect diversion of nuclear fuel (by a diverter) from a storage area such as a geological repository. Due to the complexity of operations surrounding disposal of spent nuclear fuel in a geologic repository, there are several places that a diversion of fuel could take place. After the canister that contains the fuel rods is breached, the diverter would require a hot cell to process or repackage the fuel. A reference repository and possible diversion scenarios are discussed. When a canister is breached, or during reprocessing to extract nuclear weapons material (primarily Pu), several important isotopes or signatures including tritium, {sup 85}Kr, and {sup 129}I are released to the surrounding environment and have the potential for analysis. Estimates of release concentrations of the key signatures from the repository under a hypothetical diversion scenario are presented and discussed. Gas analysis data collected from above-ground storage casks at Idaho National Engineering and Environmental Laboratory (INEEL) Test Area North (TAN) are included and discussed in the report. In addition, LANL participated in gas sampling of one TAN cask, the Castor V/21, in July 1997. Results of xenon analysis from the cask gas sample are presented and discussed. The importance of global fallout and recent commercial reprocessing activities and their effects on repository monitoring are discussed. Monitoring and instrumental equipment for analysis of the key signature isotopes are discussed along with limits of detection. A key factor in determining if diversion activities are in progress at a repository is the timeliness of detection and analysis of the signatures. Once a clandestine operation is suspected, analytical data should be collected as quickly as possible to support any evidence of diversion.

  5. Applications of liquid-phase microextraction in the sample preparation of environmental solid samples.

    Science.gov (United States)

    Prosen, Helena

    2014-05-23

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several innovative liquid-phase microextraction (LPME) techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME). Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  6. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  7. Natural Radioactivity Pattern of Surabaya Water Environmental Samples

    International Nuclear Information System (INIS)

    Rosidi; Agus Taftazani

    2007-01-01

    The gross β radioactivity and natural radionuclide of Surabaya environmental samples pattern have been evaluated. The environmental samples were chosen randomly at 12 locations. The environment samples were water (fresh, estuary and coastal), sediment, eichhornia crassipes (Mart) Solms, Mangrove (Rhizophora stylosa), (Moolgarda delicatus) fish and (Johnius (Johnieops) borneensis) (Sharpnose hammer croaker) fish. The water sample was evaporated; the sediment sample was dried and ground; the biotic samples was burnt at the temperature 500 °C ; The gross β measurement using GM detector and the radionuclides has been identified by γ spectrometer. From the investigation results could be concluded that the natural radioactivity of environmental samples was very low. gross-β of water samples were lower than the threshold value of local government regulation of Surabaya no: 2 year 2004 (1 Bq/L). The distribution of gross-β activity of eichhornia crassipes (Mart) Solms was higher than the other biotic, water and sediment samples as well as the accumulation of radionuclides in the water organism was taken place. The result of identification using γ spectrometer has detected 7 of radionuclides, i.e 210 Pb, 212 Pb, 214 Pb, 208 Tl, 214 Bi, 228 Ac, and 40 K in all sample. The distribution factor of sediment F D was less than bioaccumulation factor of biotic F B and it indicates that there the radionuclide accumulation migration follows the pattern of water - sediment - biotic sample. (author)

  8. Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

    International Nuclear Information System (INIS)

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-06-01

    This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text

  9. Environmental-benefit analysis of two urban waste collection systems.

    Science.gov (United States)

    Aranda Usón, Alfonso; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-10-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO2 emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO2-eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. Copyright © 2013 Elsevier B.V. All

  10. Analytical laboratory quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces QA guidance pertaining to design and implementation of laboratory procedures and processes for collecting DOE Environmental Restoration and Waste Management (EM) ESAA (environmental sampling and analysis activities) data. It addresses several goals: identifying key laboratory issues and program elements to EM HQ and field office managers; providing non-prescriptive guidance; and introducing environmental data collection program elements for EM-263 assessment documents and programs. The guidance describes the implementation of laboratory QA elements within a functional QA program (development of the QA program and data quality objectives are not covered here)

  11. The determination of plutonium isotopes in environmental samples

    International Nuclear Information System (INIS)

    Siripirom, Lopchai.

    1983-01-01

    The concentration of plutonium in environmental samples such as soil, water, and surface air in the middle part of Thailand were studied. The surface air were collected only at the fifth floor of the Office of Atomic Energy for Peace (OAEP). Plutonium-242 was used as a tracer. Soil and air samples were dissolved by pyrosulphate fusion, and plutonium was co-precipitated with barium sulfate. Then dissolved the precipitate in perchloric acid. Plutonium was extracted out by using solvent bis-(2-ethylhexyl) phosphoric acid (HDEHP). Plutonium in water samples were coprecipitated with iron (III) hydroxide and were dissolved in 8 M. nitric acid. Then the plutonium was separated out by using anion exchange resin, Dowex 1x4. After the solvent extraction or the anion exchange, plutonium was coprecipitated with cerous hydroxide. The activities of plutonium were measured by a surface barrier detector for about 24 hours. Lower limit of detection for 1,440 minutes is 0.012 pCi. These studies showed that only plutonium-239, 240 was observed. The range of activities of plutonium-239, 240 in soil were 0.002-0.157 pCi/g (dry), in water were 0.1-81 f Ci/l, and in air were 7-330 a Ci/m 3 . However, the plutonium concentrations in these studies are far below the maximum permissible concentration (MPC) recommended by International Commission on Radiological Protection (ICRP) for general population which is equal to 3x10 8 f Ci/l of water and 5x10 6 a Ci/m 3 of air

  12. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    Science.gov (United States)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  13. Gamma spectrometric analyses of environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Faruq, M.U.; Parveen, N.; Ahmed, B.; Aziz, A.

    1979-01-01

    Gamma spectrometric analyses of air and other environmental samples from PINSTECH were carried out. Air particulate samples were analyzed by a Ge(Li) detector on a computer-based multichannel analyzer. Other environmental samples were analyzed by a Na(T1) scintillation detector spectrometer and a multichannel analyzer with manual analysis. Concentration of radionuclides in the media was determined and the sources of their production were identified. Age of the fall out was estimated from the ratios of the fission products. (authors)

  14. Isotope dilution and sampling factors of the quality assurance and TQM of environmental analysis

    International Nuclear Information System (INIS)

    Macasek, F.

    1999-01-01

    Sampling and preparatory treatment of environmental objects is discussed from the view of their information content, functional speciation of the pollutant, statistical distribution treatment and uncertainty assessment. During homogenization of large samples, a substantial information may be lost and validity of environmental information becomes vague. Isotope dilution analysis is discussed as the most valuable tool for both validity of analysis and evaluation of samples variance. Data collection for a non-parametric statistical treatment of series of 'non-representative' sub-samples, and physico-chemical speciation of analyte may actually better fulfill criteria of similarity and representativeness. Large samples are often required due to detection limits of analysis, but the representativeness of environmental samples should by understood not only by the mean analyte concentration, but also by its spatial and time variance. Hence, heuristic analytical scenarios and interpretation of results must be designed by cooperation of environmentalists and analytical chemists. (author)

  15. Multielement fingerprinting for characterization: Earthworm samples from the environmental specimen bank of the FRG

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1988-01-01

    Earthworm samples (Lumbricidae) from three different sampling sites in the Federal Republic of Germany were collected for the German Environmental Specimen Bank (ESB). Subsamples of the cryohomogenized material from two annual samplings were analyzed by Instrumental Neutron Activation Analysis (INAA) and mean values are presented in the logarithmic fingerprint mode. The 'identical matrix reference material concept' of the ESB has been applied and proved to be of particular value for multielement determinations. (orig.)

  16. Environmental-benefit analysis of two urban waste collection systems

    International Nuclear Information System (INIS)

    Aranda Usón, Alfonso; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-01-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO 2 emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO 2 -eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. - Highlights: • A comprehensive

  17. Environmental-benefit analysis of two urban waste collection systems

    Energy Technology Data Exchange (ETDEWEB)

    Aranda Usón, Alfonso, E-mail: alaranda@unizar.es; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-10-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO{sub 2} emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO{sub 2}-eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. - Highlights: • A

  18. Zoonotic pathogens isolated from wild animals and environmental samples at two California wildlife hospitals.

    Science.gov (United States)

    Siembieda, Jennifer L; Miller, Woutrina A; Byrne, Barbara A; Ziccardi, Michael H; Anderson, Nancy; Chouicha, Nadira; Sandrock, Christian E; Johnson, Christine K

    2011-03-15

    To determine types and estimate prevalence of potentially zoonotic enteric pathogens shed by wild animals admitted to either of 2 wildlife hospitals and to characterize distribution of these pathogens and of aerobic bacteria in a hospital environment. Cross-sectional study. Fecal samples from 338 animals in 2 wildlife hospitals and environmental samples from 1 wildlife hospital. Fecal samples were collected within 24 hours of hospital admission. Environmental samples were collected from air and surfaces. Samples were tested for zoonotic pathogens via culture techniques and biochemical analyses. Prevalence of pathogen shedding was compared among species groups, ages, sexes, and seasons. Bacterial counts were determined for environmental samples. Campylobacter spp, Vibrio spp, Salmonella spp, Giardia spp, and Cryptosporidium spp (alone or in combination) were detected in 105 of 338 (31%) fecal samples. Campylobacter spp were isolated only from birds. Juvenile passerines were more likely to shed Campylobacter spp than were adults; prevalence increased among juvenile passerines during summer. Non-O1 serotypes of Vibrio cholerae were isolated from birds; during an oil-spill response, 9 of 10 seabirds screened were shedding this pathogen, which was also detected in environmental samples. Salmonella spp and Giardia spp were isolated from birds and mammals; Cryptosporidium spp were isolated from mammals only. Floors of animal rooms had higher bacterial counts than did floors with only human traffic. Potentially zoonotic enteric pathogens were identified in samples from several species admitted to wildlife hospitals, indicating potential for transmission if prevention is not practiced.

  19. Investigation of environmental conditions at Sarfartoq 1987-88. Collection of samples for testing, measurement of radon and analyses for polonium-210 and lead-210. [Greenland]. Miljoeundersoegelser ved Sarfartoq 1987-88. Proeveindsamling, radonmaaling og analyser for polonium-210 og bly-210

    Energy Technology Data Exchange (ETDEWEB)

    Aastrup, P; Munk Hansen, M

    1989-01-01

    The sampling of plants and animals is part of environmental base line studies initiated by the Mineral Resources Administration for Greenland in relation to plans for exploration and exploitation of a niobium occurence. Samples have been collected in areas expected to be influenced by mining activities and in reference areas. The collected species of plants include northern willow, Bellard's kobresia, lichen (Cetraria nivalis), and others. Samples of animals include musk oxen, reindeer, alpine hare, ptarmigan, fox, and arctic char. However, 60 samples have been analyzed for polonium-210 and lead-210. The highest concentrations were found in lichen and the lowest in muscle tissue. In many samples systematic differences between the concentrations of the two isotopes were observed indicating that polonium-210 should continue to be part of the base line study program and the monitoring program if mining is started. The observed concentrations pose no health problem. 30 kg bulk samples of the best pyrochlore ore and the rock c. 10 m on both sides of the mineralization (the side rock) were analyzed for niobium, tantalum, some trace elements, and natural radioactive isotopes. The ore sample has concentrations of 33.17% niobium, 0.4% tantalum, 0.77% uranium, and more than 0.37% rare earth elements. The concentrations of all other analyzed elements are low. The ore has very well defined boundaries and there is a very low concentration of radioactive elements in the side rock. The naturally occurring concentrations of radon have been measured at stations on top of the mineralization, within the carbonatite complex and outside the complex. The concentrations generally are very low. However, the concentrations in the complex are significantly higher than outside the complex. This reflects an elevated uranium concentration of the carbonatite complex rocks. (AB).

  20. Determination of Pu, Am and Cm in Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Lujaniene, G. [SRI Centre for Physical Sciences and Technology, Vilnius (Lithuania)

    2013-07-15

    The determination of actinides in the environmental samples at a lower detection limit is required for monitoring purposes and for environmental research. The method for Pu, Am and Cm measurements in soil and sediment samples provides high recoveries and good decontamination from interfering radionuclides. The main steps of the method involve digestion of the samples, separation of radionuclides from matrix using the TOPO /cyclohexane extraction and final purification using extraction Eichrom resins (TEVA, TRU). The accuracy and precision of Pu, Am and Cm analyses were tested using IAEA RM No 135, NIST SRM No 4350b, No 4357 and in intercomparison runs organized by the Riso National Laboratory, Denmark, and in the proficiency tests organized by National Physical Laboratory, UK. The method was applied for measurement of radionuclides in aerosol samples (ashes {approx}30 g), bottom sediments (50-80 g dr. wt) and soil (including Chernobyl soil) samples. (author)

  1. Development of analytical techniques for safeguards environmental samples at JAEA

    International Nuclear Information System (INIS)

    Sakurai, Satoshi; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, Chi-Gyu; Yasuda, Kenichiro; Inagawa, Jun; Suzuki, Daisuke; Iguchi, Kazunari; Kokubu, Yoko S.; Miyamoto, Yutaka; Ohzu, Akira

    2007-01-01

    JAEA has been developing, under the auspices of the Ministry of Education, Culture, Sports, Science and Technology of Japan, analytical techniques for ultra-trace amounts of nuclear materials in environmental samples in order to contribute to the strengthened safeguards system. Development of essential techniques for bulk and particle analysis, as well as screening, of the environmental swipe samples has been established as ultra-trace analytical methods of uranium and plutonium. In January 2003, JAEA was qualified, including its quality control system, as a member of the JAEA network analytical laboratories for environmental samples. Since 2004, JAEA has conducted the analysis of domestic and the IAEA samples, through which JAEA's analytical capability has been verified and improved. In parallel, advanced techniques have been developed in order to expand the applicability to the samples of various elemental composition and impurities and to improve analytical accuracy and efficiency. This paper summarizes the trace of the technical development in environmental sample analysis at JAEA, and refers to recent trends of research and development in this field. (author)

  2. Detection of the actinides and cesium from environmental samples

    Science.gov (United States)

    Snow, Mathew Spencer

    Detection of the actinides and cesium in the environment is important for a variety of applications ranging from environmental remediation to safeguards and nuclear forensics. The utilization of multiple different elemental concentrations and isotopic ratios together can significantly improve the ability to attribute contamination to a unique source term and/or generation process; however, the utilization of multiple elemental "signatures" together from environmental samples requires knowledge of the impact of chemical fractionation for various elements under a variety of environmental conditions (including predominantly aqueous versus arid conditions). The research reported in this dissertation focuses on three major areas: 1. Improving the understanding of actinide-mineral interactions at ultra-low concentrations. Chapter 2 reports a batch sorption and modeling study of Np(V) sorption to the mineral goethite from attomolar to micromolar concentrations. 2. Improving the detection capabilities for Thermal Ionization Mass Spectrometry (TIMS) analyses of ultra-trace cesium from environmental samples. Chapter 4 reports a new method which significantly improves the chemical yields, purification, sample processing time, and ultimately, the detection limits for TIMS analyses of femtogram quantities of cesium from a variety of environmental sample matrices. 3. Demonstrating how actinide and cesium concentrations and isotopic ratios from environmental samples can be utilized together to determine a wealth of information including environmental transport mechanisms (e.g. aqueous versus arid transport) and information on the processes which generated the original material. Chapters1, 3 and 5 demonstrate these principles using Pu, Am, Np, and Cs concentrations and isotopic ratios from contaminated soils taken near the Subsurface Disposal Area (SDA) of Idaho National Laboratory (INL) (a low level radioactive waste disposal site in southeastern Idaho).

  3. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples....... This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...

  4. Use of aspiration method for collecting brain samples for rabies diagnosis in small wild animals.

    Science.gov (United States)

    Iamamoto, K; Quadros, J; Queiroz, L H

    2011-02-01

    In developing countries such as Brazil, where canine rabies is still a considerable problem, samples from wildlife species are infrequently collected and submitted for screening for rabies. A collaborative study was established involving environmental biologists and veterinarians for rabies epidemiological research in a specific ecological area located at the Sao Paulo State, Brazil. The wild animals' brains are required to be collected without skull damage because the skull's measurements are important in the identification of the captured animal species. For this purpose, samples from bats and small mammals were collected using an aspiration method by inserting a plastic pipette into the brain through the magnum foramen. While there is a progressive increase in the use of the plastic pipette technique in various studies undertaken, it is also appreciated that this method could foster collaborative research between wildlife scientists and rabies epidemiologists thus improving rabies surveillance. © 2009 Blackwell Verlag GmbH.

  5. New Zealand guidelines for the collection of groundwater samples for chemical and isotopic analyses

    International Nuclear Information System (INIS)

    Rosen, M.R.; Cameron, S.G.; Reeves, R.R.; Taylor, C.B.

    1999-01-01

    Chemical and isotopic analyses of groundwater are important tools for differentiating between the natural composition and human-induced contaminants of groundwater. A comprehensive suite of inorganic water chemical analyses is necessary to characterise waters. The geology of New Zealand is diverse, so it is impractical to characterise a ''typical'' groundwater chemical composition. Each aquifer system should be evaluated individually because the major dissolved species contain useful information about the pathways of water through the soil zone into the aquifer. Analyses of major ions such as chloride, nitrate, potassium and sulphate often give indication of septic systems and agricultural contamination. The minor ions, while most are not considered contaminants, are often indicators of human activity. Iron and manganese are good indicators of Eh potential, which is an important control on the mobility of many heavy metals. The inexpensive inorganic chemical analytical suite should be used as a guide to advisability of more expensive contaminant testing. The purpose of this manual is to provide consistent groundwater sampling guidelines for use throughout New Zealand. Sinton's (1998) guide to groundwater sampling techniques provided a sound basis for the accurate collection of groundwater samples. However Sinton did not address sampling materials and techniques for the collection of samples for ultra trace component analysis or the collection of environmental isotope samples. These important aspects of groundwater sampling have been included in this updated manual. (author). 30 refs., 12 figs., 5 tabs., 1 appendix

  6. AAS determination of total mercury content in environmental samples

    International Nuclear Information System (INIS)

    Moskalova, M.; Zemberyova, M.

    1997-01-01

    Two methods for determination of total mercury content in environmental samples soils, and sediments, were compared. Dissolution procedure of soils, sediments, and biological material under elevated pressure followed by determination of mercury by cold vapour atomic absorption spectrometry using a MHS-1 system and direct total mercury determination without any chemical pretreatment from soil samples using a Trace Mercury Analyzer TMA-254 were compared. TMA-254 was also applied for the determination of mercury in various further standard reference materials. Good agreement with certified values of environmental reference materials was obtained. (authors)

  7. Deepwater Horizon MC252 deepwater benthic communities data from the Environmental Response Management Application (ERMA) containing sediment toxicity sample results and total polycyclic aromatic hydrocarbon (TPAH) results, habitat injury zones, mesophotic coral reef resources, and related deep-sea area injury toxicity results collected from samples taken from 2010-09-16 to 2011-12-04 in the Northern Gulf of Mexico (NCEI Accession 0163817)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This Archival Information Package (AIP) contains Environmental Resource Management Application (ERMA) GIS layers that represent sample locations for workplan...

  8. Miniature Blimps for Surveillance and Collection of Samples

    Science.gov (United States)

    Jones, Jack

    2004-01-01

    Miniature blimps are under development as robots for use in exploring the thick, cold, nitrogen atmosphere of Saturn's moon, Titan. Similar blimps can also be used for surveillance and collection of biochemical samples in buildings, caves, subways, and other, similar structures on Earth. The widely perceived need for means to thwart attacks on buildings and to mitigate the effects of such attacks has prompted consideration of the use of robots. Relative to rover-type (wheeled) robots that have been considered for such uses, miniature blimps offer the advantage of ability to move through the air in any direction and, hence, to perform tasks that are difficult or impossible for wheeled robots, including climbing stairs and looking through windows. In addition, miniature blimps are expected to have greater range and to cost less, relative to wheeled robots.

  9. Planning for the Collection and Analysis of Samples of Martian Granular Materials Potentially to be Returned by Mars Sample Return

    Science.gov (United States)

    Carrier, B. L.; Beaty, D. W.

    2017-12-01

    NASA's Mars 2020 rover is scheduled to land on Mars in 2021 and will be equipped with a sampling system capable of collecting rock cores, as well as a specialized drill bit for collecting unconsolidated granular material. A key mission objective is to collect a set of samples that have enough scientific merit to justify returning to Earth. In the case of granular materials, we would like to catalyze community discussion on what we would do with these samples if they arrived in our laboratories, as input to decision-making related to sampling the regolith. Numerous scientific objectives have been identified which could be achieved or significantly advanced via the analysis of martian rocks, "regolith," and gas samples. The term "regolith" has more than one definition, including one that is general and one that is much more specific. For the purpose of this analysis we use the term "granular materials" to encompass the most general meaning and restrict "regolith" to a subset of that. Our working taxonomy includes the following: 1) globally sourced airfall dust (dust); 2) saltation-sized particles (sand); 3) locally sourced decomposed rock (regolith); 4) crater ejecta (ejecta); and, 5) other. Analysis of martian granular materials could serve to advance our understanding areas including habitability and astrobiology, surface-atmosphere interactions, chemistry, mineralogy, geology and environmental processes. Results of these analyses would also provide input into planning for future human exploration of Mars, elucidating possible health and mechanical hazards caused by the martian surface material, as well as providing valuable information regarding available resources for ISRU and civil engineering purposes. Results would also be relevant to matters of planetary protection and ground-truthing orbital observations. We will present a preliminary analysis of the following, in order to generate community discussion and feedback on all issues relating to: What are the

  10. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  11. Determination of uranium and its isotopic ratios in environmental samples

    International Nuclear Information System (INIS)

    Flues Szeles, M.S.M.

    1990-01-01

    A method for the determination of uranium and its isotopic ratios ( sup(235)U/ sup(238)U and sup(234U/ sup(238)U) is established in the present work. The method can be applied in environmental monitoring programs of uranium enrichment facilities. The proposed method is based on the alpha spectrometry technique which is applied after a purification of the sample by using an ionic exchange resin. The total yield achieved was (91 + 5)% with a precision of 5%, an accuracy of 8% and a lower limit of detection of 7,9 x 10 sup(-4)Bq. The uranium determination in samples containing high concentration of iron, which is an interfering element present in environmental samples, particularly in soil and sediment, was also studied. The results obtained by using artificial samples containing iron and uranium in the ratio 1000:1, were considered satisfactory. (author)

  12. Hanford Environmental Monitoring Program schedule for samples, analyses, and measurements for calendar year 1985

    International Nuclear Information System (INIS)

    Blumer, P.J.; Price, K.R.; Eddy, P.A.; Carlile, J.M.V.

    1984-12-01

    This report provides the CY 1985 schedule of data collection for the routine Hanford Surface Environmental Monitoring and Ground-Water Monitoring Programs at the Hanford Site. The purpose is to evaluate and report the levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5484.1. The routine sampling schedule provided herein does not include samples scheduled to be collected during FY 1985 in support of special studies, special contractor support programs, or for quality control purposes. In addition, the routine program outlined in this schedule is subject to modification during the year in response to changes in site operations, program requirements, or unusual sample results

  13. Gamma-ray self-attenuation corrections in environmental samples

    International Nuclear Information System (INIS)

    Robu, E.; Giovani, C.

    2009-01-01

    Gamma-spectrometry is a commonly used technique in environmental radioactivity monitoring. Frequently the bulk samples that should be measured differ with respect to composition and density from the reference sample used for efficiency calibration. Correction factors should be applied in these cases for activity measurement. Linear attenuation coefficients and self-absorption correction factors have been evaluated for soil, grass and liquid sources with different densities and geometries.(authors)

  14. Fluoroquinolone antibiotics in environmental waters: sample preparation and determination.

    Science.gov (United States)

    Speltini, Andrea; Sturini, Michela; Maraschi, Federica; Profumo, Antonella

    2010-04-01

    The aim of this review is to provide a general overview on the analytical methods proposed in the last decade for trace fluoroquinolone (FQ) determination in environmental waters. A large number of studies have been developed on this topic in reason of the importance of their monitoring in the studies of environmental mobility and potential degradation pathways. Every step of the analysis has been carefully considered, with a particular attention to sample preparation, in relationship with the problems involved in the analysis of real matrices. The different strategies to minimise interference from organic matter and to achieve optimal sensitivity, especially important in those samples with lower FQ concentrations, were also highlighted. Results and progress in this field have been described and critically commented. Moreover, a worldwide overview on the presence of FQs in the environmental waters has been reported.

  15. Rapid methods for measuring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    Perkins, Richard W.

    1995-01-01

    The application of ICP/mass spectrometry for the isotopic analysis of environmental samples, the use of drum assayers for measuring radionuclides in food and a rapid procedure for the measurement of the transuranic elements and thorium, performed at the Pacific Northwest Laboratory are discussed

  16. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  17. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  18. Detection and Molecular Characterization of Gemycircularvirus from Environmental Samples in Brazil.

    Science.gov (United States)

    da Silva Assis, Matheus Ribeiro; Vieira, Carmen Baur; Fioretti, Julia Monassa; Rocha, Mônica Simões; de Almeida, Pedro Ivo Neves; Miagostovich, Marize Pereira; Fumian, Tulio Machado

    2016-12-01

    Gemycircularvirus (GemyCV) is a group of viruses which has been recently proposed as a new viral genus detected in fecal and environmental samples around the world. GemyCVs have been detected in human blood, brain tissue, cerebrospinal fluid, and stool sample. In the present study, we demonstrate for the first time, through molecular detection and characterization, the presence of GemyCVs in environmental samples from Brazil. Our results show a percentage of positivity ranging from 69 (25/36) to 97 % (35/36) in river water samples collected in Manaus, Amazon region, and wastewater from a wastewater treatment plant located in Rio de Janeiro, respectively, revealing GemyCVs as an important environmental contaminant.

  19. Infrared characterization of environmental samples by pulsed photothermal spectroscopy

    International Nuclear Information System (INIS)

    Seidel, W.; Foerstendorf, H.; Heise, K.H.; Nicolai, R.; Schamlott, A.; Ortega, J.M.; Glotin, F.; Prazeres, R.

    2004-01-01

    Low concentration of toxic radioactive metals in environmental samples often limits the interpretation of results of infrared studies investigating the interaction processes between the metal ions and environmental compartments. For the first time, we could show that photothermal infrared spectroscopy performed with a pulsed free electron laser can provide reliable infrared spectra throughout a distinct spectral range of interest. In this model investigation, we provide vibrational absorption spectra of a rare earth metal salt dissolved in a KBr matrix and a natural calcite sample obtained by photothermal beam deflection (PTBD) technique and FT-IR (Fourier-transform infrared) spectroscopy, respectively. General agreement was found between all spectra of the different recording techniques. Spectral deviations were observed with samples containing low concentration of the rare earth metal salt indicating a lower detection limit of the photothermal method as compared to conventional FT-IR spectroscopy. (authors)

  20. Determination of carbon-14 environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia Sanz, M.R.; Gomez, V.; Heras, M.C.; Beltran, M.A.

    1990-01-01

    A method for the determination of Carbon-14 ( 14 CO 2 ) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO 2 ) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discused and compared. The method of collection of atmospheric samples is also described. (Author)

  1. Determination of Carbon-14 in environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia, M. R.; Gomez, V.; Heras, M. C.; Beltran, M. A.

    1990-01-01

    A method for the determination of Carbon-14 (14CO2) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO2) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discussed and compared. The method of collection of atmospheric samples is also described. (Author) 10 refs

  2. Hanford Environmental Information System (HEIS). Volume 7: Sample and Data Tracking subject area

    International Nuclear Information System (INIS)

    1994-06-01

    The Hanford Environmental Information System (HEIS) Sample and Data Tracking subject area allows insertion of tracking information into a central repository where the data is immediately available for viewing. For example, a technical coordinator is able to view the current status of a particular sampling effort, from sample collection to data package validation dates. Four major types of data comprise the Sample and Data Tracking subject area: data about the mechanisms that groups a set of samples for a particular sampling effort; data about how constituents are grouped and assigned to a sample; data about when, where, and how samples are sent to a laboratory for analysis; and data bout the status of a sample's constituent analysis requirements, i.e., whether the analysis results have been returned from the laboratory

  3. Metagenomic analyses of novel viruses and plasmids from a cultured environmental sample of hyperthermophilic neutrophiles

    DEFF Research Database (Denmark)

    Garrett, Roger Antony; Prangishvili, David; Shah, Shiraz Ali

    2010-01-01

    Two novel viral genomes and four plasmids were assembled from an environmental sample collected from a hot spring at Yellowstone National Park, USA, and maintained anaerobically in a bioreactor at 85°C and pH 6. The double-stranded DNA viral genomes are linear (22.7 kb) and circular (17.7 kb...... respectively. Strategies are considered for assembling genomes of smaller genetic elements from complex environmental samples, and for establishing possible host identities on the basis of sequence similarity to host CRISPR immune systems....

  4. Sorption models and their application in environmental samples

    International Nuclear Information System (INIS)

    Kamel, Nariman H.M.

    2008-01-01

    Full text: Naturally occurring radioactive materials (NORM) were found in some environmental soils not high enough to pose problems for human health. The health may be affected by increasing of NORM at some environmental soils. Four soil samples obtained from certain coastal regions in Egypt. Naturally occurring radioactive materials (NORM) of the uranium ( 238 U) series, thorium ( 232 Th) series and the radioactive isotope of potassium ( 40 K) were measured. The soil samples were selected from the situations where the radionuclide concentrations are significantly higher than the average level of other sites. It were chemically analyzed for the uranium, silicon aluminum and iron. The cation exchange capacity (CEC) were determined, it was found lower in the presence of Fe-silicates suggested that Fe-hydroxide had precipitin at the exchangeable edge sites of the clay minerals. The pH of the solid particles at which the net total surface charge is zero was known as the point of zero charge (PZC). The PZC is very important in determining the affinity of the soil samples for different cations and anions. The aim of this work is to determine the natural radiological hazardous of radionuclide at four environmental coastal soil samples in Egypt. The point of zero surface charge was determined using titration tests. Sorption model was developed for this purpose. (author)

  5. Optimizing detection of noble gas emission at a former UNE site: sample strategy, collection, and analysis

    Science.gov (United States)

    Kirkham, R.; Olsen, K.; Hayes, J. C.; Emer, D. F.

    2013-12-01

    Underground nuclear tests may be first detected by seismic or air samplers operated by the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization). After initial detection of a suspicious event, member nations may call for an On-Site Inspection (OSI) that in part, will sample for localized releases of radioactive noble gases and particles. Although much of the commercially available equipment and methods used for surface and subsurface environmental sampling of gases can be used for an OSI scenario, on-site sampling conditions, required sampling volumes and establishment of background concentrations of noble gases require development of specialized methodologies. To facilitate development of sampling equipment and methodologies that address OSI sampling volume and detection objectives, and to collect information required for model development, a field test site was created at a former underground nuclear explosion site located in welded volcanic tuff. A mixture of SF-6, Xe127 and Ar37 was metered into 4400 m3 of air as it was injected into the top region of the UNE cavity. These tracers were expected to move towards the surface primarily in response to barometric pumping or through delayed cavity pressurization (accelerated transport to minimize source decay time). Sampling approaches compared during the field exercise included sampling at the soil surface, inside surface fractures, and at soil vapor extraction points at depths down to 2 m. Effectiveness of various sampling approaches and the results of tracer gas measurements will be presented.

  6. Filtration recovery of extracellular DNA from environmental water samples

    Science.gov (United States)

    qPCR methods are able to analyze DNA from microbes within hours of collecting water samples, providing the promptest notification and public awareness possible when unsafe pathogenic levels are reached. Health risk, however, may be overestimated by the presence of extracellular ...

  7. Nuclear analytical techniques and their application to environmental samples

    International Nuclear Information System (INIS)

    Lieser, K.H.

    1986-01-01

    A survey is given on nuclear analytical techniques and their application to environmental samples. Measurement of the inherent radioactivity of elements or radionuclides allows determination of natural radioelements (e.g. Ra), man-made radioelements (e.g. Pu) and radionuclides in the environment. Activation analysis, in particular instrumental neutron activation analysis, is a very reliable and sensitive method for determination of a great number of trace elements in environmental samples, because the most abundant main constituents are not activated. Tracer techniques are very useful for studies of the behaviour and of chemical reactions of trace elements and compounds in the environment. Radioactive sources are mainly applied for excitation of characteristic X-rays (X-ray fluorescence analysis). (author)

  8. Results of tritium measurement in environmental samples and drainage

    International Nuclear Information System (INIS)

    Koike, Ryoji; Hirai, Yasuo

    1983-01-01

    In Ibaraki prefecture, the tritium concentration in the drainage from the nuclear facilities has been measured since 1974. Then, with the start of operation of the fuel reprocessing plant in 1977, the tritium concentration in environmental samples was to be measured also in order to examine the effect of the drainage on the environment. The results of the tritium measurement in Ibaraki prefecture up to about 1980 are described: sampling points, sampling and measuring methods, the tritium concentration in the drainage, air, inland water and seawater, respectively. The drainages have been taken from Japan Atomic Power Company, Japan Atomic Energy Research Institute, and Power Reactor and Nuclear Fuel Development Corporation (with the fuel reprocessing plant). The samples of air, inland water and seawater have been taken in the areas concerned. The tritium concentration was measured by a low-background liquid scintillation counter. The measured values in the environment have been generally at low level, not different from other areas. (Mori, K.)

  9. Spectrophotometric Determination of Boron in Environmental Water Samples

    International Nuclear Information System (INIS)

    San San; Khin Win Kyi; Kwaw Naing

    2002-02-01

    The present paper deals with the study on the methods for the determination of boron in the environmental water samples. The standard methods which are useful for this determination are discussed thoroughly in this work. Among the standard methods approved by American Public Health Association, the carmine method was selected for this study. Prior to the determination of boron in the water samples, the precision and accuracy of the methods of choice were examined by using standard boron solutions. The determination of Boron was carried out by using water samples, waste water from Aquaculture Research Centre, University of Yangon, the Ayeyarwady River water near Magway Myathalon Pagoda in Magway Division, ground water from Sanchaung Township, and tap water from Universities' Research Centre, University of Yangon. Analyses of these water samples were done and statistical treatment of the results was carried out. (author)

  10. Development of environmental sample analysis techniques for safeguards

    International Nuclear Information System (INIS)

    Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka

    1999-01-01

    JAERI has been developing environmental sample analysis techniques for safeguards and preparing a clean chemistry laboratory with clean rooms. Methods to be developed are a bulk analysis and a particle analysis. In the bulk analysis, Inductively-Coupled Plasma Mass Spectrometer or Thermal Ionization Mass Spectrometer are used to measure nuclear materials after chemical treatment of sample. In the particle analysis, Electron Probe Micro Analyzer and Secondary Ion Mass Spectrometer are used for elemental analysis and isotopic analysis, respectively. The design of the clean chemistry laboratory has been carried out and construction will be completed by the end of March, 2001. (author)

  11. Sample test cases using the environmental computer code NECTAR

    International Nuclear Information System (INIS)

    Ponting, A.C.

    1984-06-01

    This note demonstrates a few of the many different ways in which the environmental computer code NECTAR may be used. Four sample test cases are presented and described to show how NECTAR input data are structured. Edited output is also presented to illustrate the format of the results. Two test cases demonstrate how NECTAR may be used to study radio-isotopes not explicitly included in the code. (U.K.)

  12. Sample collection: an overview of the Hydrogeochemical and Stream Sediment Reconnaissance Program

    International Nuclear Information System (INIS)

    Bolivar, S.L.

    1979-01-01

    A Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) for uranium is currently being conducted throughout the conterminous United States and Alaska. The HSSR is part of the National Uranium Resource Evaluation sponsored by the US Department of Energy. This ambitious geochemical reconnaissance program is conducted by four national laboratories: Los Alamos Scientific Laboratory, Lawrence Livermore Laboratory, Oak Ridge Gaseous Diffusion Plant, and Savannah River Laboratory. The program is based on an extensive review of world literature, reconnaissance work done in other countries, and pilot studies conducted by each laboratory. Sample-collection methods and sample density are determined to optimize the probability of detecting potential uranium mineralization. To achieve this aim, each laboratory has developed independent standardized field collection procedures that are designed for its section of the country. Field parameters such as pH, conductivity, climate, geography, and geology are recorded at each site. Most samples are collected at densities of one sample site per 10 to 23 km 2 . The HSSR program has helped to improve existing hydrogeochemical reconnaissance exploration techniques. In addition to providing industry with data that may help to identify potential uranium districts and to extend known uranium provinces, the HSSR also provides multi-element analytical data, which can be used in water quality, soil, sediment, environmental, and base-metal exploration studies

  13. Environmental sampling: Issues for the cut-off regime

    International Nuclear Information System (INIS)

    Fearey, B.L.

    1995-01-01

    The fissile material cut-off treaty (FMCT) initiative under the Conference on Disarmament mandate is envisioned to include certain aspects of environmental sampling and monitoring. One of the intents of this treaty is to bring certain non-NPT signatories (e.g., threshold states) under this treaty agreement along with the nuclear weapon states (NWSs). This paper provides a brief overview of some of the relevant issues that may be involved in the implementation and use of environmental monitoring for (1) verification of the cut-off regime declarations, (2) the detection of undeclared activities, and, (3) application in non-routine inspections. The intent is to provide backstopping information important for treaty negotiators. Specific issues addressed within this paper include signature sampling, differences in the proposed detection regime, potential signature integrators, specific examples and spoofing concerns. Many of these issues must be carefully considered and weighed in order to create a credibly verifiable inspection regime. Importantly, the cut-off treaty must enable nondiscriminatory implementation, while carefully assuring that nonproliferation treaty requirements are maintained (i.e., preventing unintentional release of critical weapons design information--potentially through environmental sampling and analysis)

  14. Transuranium analysis methodologies for biological and environmental samples

    International Nuclear Information System (INIS)

    Wessman, R.A.; Lee, K.D.; Curry, B.; Leventhal, L.

    1978-01-01

    Analytical procedures for the most abundant transuranium nuclides in the environment (i.e., plutonium and, to a lesser extent, americium) are available. There is a lack of procedures for doing sequential analysis for Np, Pu, Am, and Cm in environmental samples, primarily because of current emphasis on Pu and Am. Reprocessing requirements and waste disposal connected with the fuel cycle indicate that neptunium and curium must be considered in environmental radioactive assessments. Therefore it was necessary to develop procedures that determine all four of these radionuclides in the environment. The state of the art of transuranium analysis methodology as applied to environmental samples is discussed relative to different sample sources, such as soil, vegetation, air, water, and animals. Isotope-dilution analysis with 243 Am ( 239 Np) and 236 Pu or 242 Pu radionuclide tracers is used. Americium and curium are analyzed as a group, with 243 Am as the tracer. Sequential extraction procedures employing bis(2-ethyl-hexyl)orthophosphoric acid (HDEHP) were found to result in lower yields and higher Am--Cm fractionation than ion-exchange methods

  15. Analysis of polychlorinated n-alkanes in environmental samples.

    Science.gov (United States)

    Santos, F J; Parera, J; Galceran, M T

    2006-10-01

    Polychlorinated n-alkanes (PCAs), also known as chlorinated paraffins (CPs), are highly complex technical mixtures that contain a huge number of structural isomers, theoretically more than 10,000 diastereomers and enantiomers. As a consequence of their persistence, tendency to bioaccumulation, and widespread and unrestricted use, PCAs have been found in aquatic and terrestrial food webs, even in rural and remote areas. Recently, these compounds have been included in regulatory programs of several international organizations, including the US Environmental Protection Agency and the European Union. Consequently, there is a growing demand for reliable methods with which to analyze PCAs in environmental samples. Here, we review current trends and recent developments in the analysis of PCAs in environmental samples such as air, water, sediment, and biota. Practical aspects of sample preparation, chromatographic separation, and detection are covered, with special emphasis placed on analysis of PCAs using gas chromatography-mass spectrometry. The advantages and limitations of these techniques as well as recent improvements in quantification procedures are discussed.

  16. A Prototype Ice-Melting Probe for Collecting Biological Samples from Cryogenic Ice at Low Pressure

    Science.gov (United States)

    Davis, Ashley

    2017-08-01

    In the Solar System, the surface of an icy moon is composed of irregular ice formations at cryogenic temperatures (pumps. The device contains a heated conical probe with a central orifice, which is forced into surface ice and directs the meltwater upward into a reservoir. The force on the probe is proportional to the height of meltwater (pressure) obtained in the system and allows regulation of the melt rate and temperature of the sample. The device can collect 5-50 mL of meltwater from the surface of an ice block at 233-208 K with an environmental pressure of less than 10-2 atm while maintaining a sample temperature between 273 and 293 K. These conditions maintain most biological samples in a pristine state and maintain the integrity of most organisms' structure and function.

  17. Effects of Blood Sample Collection Pre- and Post- Slaughter, Edta ...

    African Journals Online (AJOL)

    The samples were immediately subjected to Wet mount (WM), Haemotocrit centrifugation test (HCT) and Thin smear (TS) tests. The results revealed that, of the 100 samples examined, 19 (19%) were positive for the presence of Microfilaria spp while 6(6%) yielded Trypanosome spp. Of the 19 samples detected having ...

  18. Automatic collection of bovine blood samples | Hale | South African ...

    African Journals Online (AJOL)

    A technique is described which allows automatic collection of jugular venous blood from tethered cows. In this system, blood is pumped continuously from an intravenous cannula which has a double lumen while an anticoagulant is pumped through the second opening. Diluted blood is collected in a fraction collector which ...

  19. Design of the CERN MEDICIS Collection and Sample Extraction System

    CERN Document Server

    Brown, Alexander

    MEDICIS is a new facility at CERN ISOLDE that aims to produce radio-isotopes for medical research. Possible designs for the collection and transport system for the collection of radio-isotopes was investigated. A system using readily available equipment was devised with the the aim of keeping costs to a minimum whilst maintaining the highest safety standards. FLUKA, a Monte Carlo radiation transport code, was used to simulate the radiation from the isotopes to be collected. Of the isotopes to be collected 44Sc was found to give the largest dose by simulating the collection of all isotopes of interest to CERN’s MEDICIS facility, for medical research. The simulations helped guide the amount of shielding used in the final design. Swiss Regulations stipulating allowed activity level of individual isotopes was also considered within the body of the work.

  20. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  1. Direct separation of plutonium by thermochromatography from environmental samples

    International Nuclear Information System (INIS)

    Wacker, L.; Kraehenbuehl, U.

    2002-01-01

    A thermochromatographic separation was performed on plutonium from environmental soil samples. This procedure was investigated with the goal to measure low concentrations of plutonium by inductively coupled plasma-mass spectrometry (ICP-MS). The soil sample was chlorinated by thionylchloride as reactive gas at a temperature of 1400 K. The volatile chlorides were separated chromatographically and deposited in a temperature gradient tube filled with quartz grains. Results about the deposition behaviour of the elements were obtained. Two different formalisms based on the thermodynamic functions are used to describe the experimental data. One formula is used to describe the deposition behaviour of microscopic amounts of plutonium (adsorption), the other formula for macroamounts of the main matrix elements (desublimation). The calculated values are in a reasonable agreement with the experimental data. A determination of plutonium content was successfully made for a referenced sea sediment (IAEA-135) after the thermochromatographic sample preparation for ICP-MS. (orig.)

  2. The measure of radiocarbon in the drating of environmental samples

    International Nuclear Information System (INIS)

    Ruiz Pessenda, L.C.; Camargo, P.B. de

    1990-01-01

    An analytical system for radiocarbon dating of environmental samples (charcoal, shell, wood, etc.) using low level liquid scintillation spectrometry has been developed and optimized at Center for Nuclear Energy in Agriculture of the University of Sao Paulo. Physical and chemical pretreatment of samples to remove oils, resins, carbonates and fulvic and humic acids; the benzene synthesis of NBS oxalic acid standard, calcium carbonate P.A. and marble and the results of benzene yield; the optimization of radiocarbon counting window; the effect of scintillators PPO-POPOP and butyl PBD on the efficiency of detection and background of radiocarbon, are described. Samples of charcoal, shell and wood, previously dated at the radiocarbon laboratories of Centre des Faibles Radioactives, France, and Instituto de Geociencias of USP, are analysed for preliminary laboratory intercomparison. (author) [pt

  3. [Collective health, territorial and environmental conflicts: bases for a critical socio-environmental approach].

    Science.gov (United States)

    Porto, Marcelo Firpo de Souza; da Rocha, Diogo Ferreira; Finamore, Renan

    2014-10-01

    The phenomenon of globalization and the increase in neo-extractivism in the global periphery intensify the search for new territories and natural resources for the economy, resulting in significant impacts on ecosystems and on the lives of vulnerable populations. It is considered that the environmental crisis imposes new challenges and requires an updating of the theoretical and methodological foundations of collective health and the social determinants of health. The scope of this paper is to present theoretical contributions to the construction of a critical socio-environmental approach from a review of the literature structured around previous work on the mapping of environmental conflicts, and conducting empirical studies in conflicting areas. The contributions of sociology, political ecology, postcolonial studies and geography is summarized for the discussion of the socio-environmental determinants of health, as well as experiences that integrate emancipatory knowledge, political subjects, resistances and alternatives for society.

  4. Prospects for the introduction of Wide Area Monitoring Using Environmental Sampling

    International Nuclear Information System (INIS)

    Wogman, N.A.

    2013-01-01

    Nuclear proliferation signatures released to the environment must be collected and distinguished from primordial and man-made backgrounds in soils, sediments, air, and surface and underground water. The delay time between the nuclear proliferation emissions and the date of the Wide-Area Environmental Sampling (WAES) analysis will determine which radionuclides would be analyzed based upon their half-lives. Various sampling and analysis technologies have been considered here for application to a WAES. Sampling procedures and equipment discussed are aimed at aquatic, airborne particulate, gas, vegetation, sediment and/or soil, and fauna media. Specific procedures must be selected based upon the application scenario; for example, sampling in the northern latitudes under freezing conditions, sampling at the equator under tropical rain-forest conditions, sampling in the mid-latitudes under desert conditions, and sampling in the marine environment require different equipment and procedures. The paper is followed by the slides of the presentation

  5. Use of immunomagnetic separation for the detection of Desulfovibrio vulgaris from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, R.; Hazen, T.C.; Joyner, D.C.; Kusel, K.; Singer, M.E.; Sitte, J.; Torok, T.

    2011-04-15

    Immunomagnetic separation (IMS) has proved highly efficient for recovering microorganisms from heterogeneous samples. Current investigation targeted the separation of viable cells of the sulfate-reducing bacterium, Desulfovibrio vulgaris. Streptavidin-coupled paramagnetic beads and biotin labeled antibodies raised against surface antigens of this microorganism were used to capture D. vulgaris cells in both bioreactor grown laboratory samples and from extremely low-biomass environmental soil and subsurface drilling samples. Initial studies on detection, recovery efficiency and viability for IMS were performed with laboratory grown D. vulgaris cells using various cell densities. Efficiency of cell isolation and recovery (i.e., release of the microbial cells from the beads following separation) was followed by microscopic imaging and acridine orange direct counts (AODC). Excellent recovery efficiency encouraged the use of IMS to capture Desulfovibrio spp. cells from low-biomass environmental samples. The environmental samples were obtained from a radionuclide-contaminated site in Germany and the chromium (VI)-contaminated Hanford site, an ongoing bioremediation project of the U.S. Department of Energy. Field deployable IMS technology may greatly facilitate environmental sampling and bioremediation process monitoring and enable transcriptomics and proteomics/metabolomics-based studies directly on cells collected from the field.

  6. The collection and field chemical analysis of water samples

    International Nuclear Information System (INIS)

    Korte, N.E.; Ealey, D.T.; Hollenbach, M.H.

    1984-01-01

    A successful water sampling program requires a clear understanding of appropriate measurement and sampling procedures in order to obtain reliable field data and representative samples. It is imperative that the personnel involved have a thorough knowledge of the limitations of the techniques being used. Though this seems self-evident, many sampling and field-chemical-analysis programs are still not properly conducted. Recognizing these problems, the Department of Energy contracted with Bendix Field Engineering Corporation through the Technical Measurements Center to develop and select procedures for water sampling and field chemical analysis at waste sites. The fundamental causese of poor field programs are addressed in this paper, largely through discussion of specific field-measurement techniques and their limitations. Recommendations for improvement, including quality-assurance measures, are also presented

  7. Concordance analysis of methylation biomarkers detection in self-collected and physician-collected samples in cervical neoplasm

    International Nuclear Information System (INIS)

    Chang, Cheng-Chang; Huang, Rui-Lan; Liao, Yu-Ping; Su, Po-Hsuan; Hsu, Yaw-Wen; Wang, Hui-Chen; Tien, Chau-Yang; Yu, Mu-Hsien; Lin, Ya-Wen; Lai, Hung-Cheng

    2015-01-01

    Non-attendance at gynecological clinics is a major limitation of cervical cancer screening and self-collection of samples may improve this situation. Although HPV testing of self-collected vaginal samples is acceptable, the specificity is inadequate. The current focus is increasing self-collection of vaginal samples to minimize clinic visits. In this study, we analyzed the concordance and clinical performance of DNA methylation biomarker (PAX1, SOX1, and ZNF582) detection in self-collected vaginal samples and physician-collected cervical samples for the identification of cervical neoplasm. We enrolled 136 cases with paired methylation data identified from abnormal Pap smears (n = 126) and normal controls (n = 10) regardless of HPV status at gynecological clinics. The study group comprised 37 cervical intraepithelial neoplasm I (CIN1), 23 cervical intraepithelial neoplasm II (CIN2), 16 cervical intraepithelial neoplasm III (CIN3), 30 carcinoma in situ (CIS), 13 squamous cell carcinomas (SCCs) and seven adenocarcinomas (ACs)/adenosquamous carcinomas (ASCs). PAX1, SOX1 and ZNF582 methylation in study samples was assessed by real-time quantitative methylation-specific polymerase chain reaction analysis. We generated methylation index cutoff values for the detection of CIN3+ in physician-collected cervical samples for analysis of the self-collected group. Concordance between the physician-collected and self-collected groups was evaluated by Cohen’s Kappa. Sensitivity, specificity and area under curve (AUC) were calculated for detection of CIN3+ lesions. Finally, we produced an optimal cutoff value with the best sensitivity from the self-collected groups. We generated a methylation index cutoff value from physician-collected samples for detection of CIN3+. There were no significant differences in sensitivity, specificity of PAX1, SOX1 and ZNF582 between the self-collected and physician-collected groups. The methylation status of all three genes in the normal control

  8. Molecular Identification of Gambierdiscus and Fukuyoa (Dinophyceae from Environmental Samples

    Directory of Open Access Journals (Sweden)

    Kirsty F. Smith

    2017-08-01

    Full Text Available Ciguatera Fish Poisoning (CFP is increasing across the Pacific and the distribution of the causative dinoflagellates appears to be expanding. Subtle differences in thecal plate morphology are used to distinguish dinoflagellate species, which are difficult to determine using light microscopy. For these reasons we sought to develop a Quantitative PCR assay that would detect all species from both Gambierdiscus and Fukuyoa genera in order to rapidly screen environmental samples for potentially toxic species. Additionally, a specific assay for F. paulensis was developed as this species is of concern in New Zealand coastal waters. Using the assays we analyzed 31 samples from three locations around New Zealand and the Kingdom of Tonga. Fourteen samples in total were positive for Gambierdiscus/Fukuyoa and two samples were also positive using the F. paulensis assay. Samples from the Kermadec Islands were further characterized using high-throughput sequencing metabarcoding. The majority of reads corresponded to Gambierdiscus species with three species identified at all sites (G. australes, G. honu and G. polynesiensis. This is the first confirmed identification of G. polynesiensis, a known ciguatoxin producer, in New Zealand waters. Other known toxin-producing genera were also detected, included Alexandrium, Amphidinium, Azadinium, Dinophysis, Ostreopsis, and Prorocentrum.

  9. Rapid extraction and assay of uranium from environmental surface samples

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Christopher A.; Chouyyok, Wilaiwan; Speakman, Robert J.; Olsen, Khris B.; Addleman, Raymond Shane

    2017-10-01

    Extraction methods enabling faster removal and concentration of uranium compounds for improved trace and low-level assay are demonstrated for standard surface sampling material in support of nuclear safeguards efforts, health monitoring, and other nuclear analysis applications. A key problem with the existing surface sampling swipes is the requirement for complete digestion of sample and sampling matrix. This is a time-consuming and labour-intensive process that limits laboratory throughput, elevates costs, and increases background levels. Various extraction methods are explored for their potential to quickly and efficiently remove different chemical forms of uranium from standard surface sampling material. A combination of carbonate and peroxide solutions is shown to give the most rapid and complete form of uranyl compound extraction and dissolution. This rapid extraction process is demonstrated to be compatible with standard inductive coupled plasma mass spectrometry methods for uranium isotopic assay as well as screening techniques such as x-ray fluorescence. The general approach described has application beyond uranium to other analytes of nuclear forensic interest (e.g., rare earth elements and plutonium) as well as heavy metals for environmental and industrial hygiene monitoring.

  10. Nonactivation interaction techniques in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    Nonactivation interaction analytical methods are based on the interaction processes of nuclear and X-ray radiation with a sample, leading to their absorption and backscattering, to the ionization of gases or excitation of fluorescent X-ray by radiation, but not to the activation of determined elements. From the point of view of environmental analysis, the most useful nonactivation interaction techniques are X-ray fluorescence by photon or charged particle excitation, ionization of gases by nuclear radiation, elastic scattering of charged particles and backscattering of beta radiation. The significant advantage of these methods is that they are nondestructive. (author)

  11. Concentration and speciation of radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Testa, C.; Desideri, D.; Meli, M.A.; Roselli, C.

    2000-01-01

    The paper will describe three examples dealing with the measure of some natural (U, Th, 2 10Pb, 4 0K) and artificial ( 1 37Cs, 9 0Sr, 2 39 +2 40Pu, 2 41Am) radionuclides in environmental samples such as mosses, sediments, soils. Extraction chromatography, liquid extraction, selective precipitation and electroplating were used to isolate the radionuclides, except for gamma emitters which were detected by gamma spectrometry. Alpha spectrometry were used to measure the alpha emitters and low background beta detector to measure the beta emitters

  12. Spectrophotometric determination of vanadium in environmental and biological samples

    International Nuclear Information System (INIS)

    Rekha, D.; Krishnapriya, B.; Subrahmanyam, P.; Reddyprasad, P.; Dilip Kumar, J.; Chiranjeevi, P.

    2007-01-01

    The method is based on oxidation of p-nitro aniline by vanadium (V) followed by coupling reaction with N-(1-naphthalene-1-y1)ethane-1, 2-diaminedihydrochloride (NEDA) in basic medium of pH 8 to give purple colored derivative. The derivative having an λ max 525nm is stable for 10 days. Beer's law is obeyed for vanadium (V) in the concentration range of 0.03-4.5 μg ml -1 . The proposed method was successfully applied to the analysis of vanadium in environmental and biological samples. (author)

  13. Stability of volatile organics in environmental soil samples. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Maskarinec, M.P.; Bayne, C.K.; Jenkins, R.A.; Johnson, L.H.; Holladay, S.K.

    1992-11-01

    This report focuses on data generated for the purpose of establishing the stability of 19 volatile organic compounds in environmental soil samples. The study was carried out over a 56 day (for two soils) and a 111 day (for one reference soil) time frame and took into account as many variables as possible within the constraints of budget and time. The objectives of the study were: 1) to provide a data base which could be used to provide guidance on pre-analytical holding times for regulatory purposes; and 2) to provide a basis for the evaluation of data which is generated outside of the currently allowable holding times.

  14. Stability of volatile organics in environmental soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Maskarinec, M.P.; Bayne, C.K.; Jenkins, R.A.; Johnson, L.H.; Holladay, S.K.

    1992-11-01

    This report focuses on data generated for the purpose of establishing the stability of 19 volatile organic compounds in environmental soil samples. The study was carried out over a 56 day (for two soils) and a 111 day (for one reference soil) time frame and took into account as many variables as possible within the constraints of budget and time. The objectives of the study were: 1) to provide a data base which could be used to provide guidance on pre-analytical holding times for regulatory purposes; and 2) to provide a basis for the evaluation of data which is generated outside of the currently allowable holding times.

  15. Sampling and measurement of long-lived radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Brauer, F.P.; Goles, R.W.; Kaye, J.H.; Rieck, H.G. Jr.

    1977-01-01

    The volatile and semivolatile long-lived man-made radionuclides 3 H, 14 C, 79 Se, 85 Kr, 99 Tc, 129 I, 135 Cs, and 137 Cs are of concern in operation of nuclear facilities because they are difficult and expensive to contain and once emitted to the environment they become permanent ecological constituents with both local and global distributions. Species-selective sampling and analytical methods (radiochemical, neutron activation, and mass spectrometric) have been developed for many of these nuclides with sensitivities well below those required for radiation protection. These sampling and analytical methods have been applied to the measurement of current environmental levels of some of the more ecologically important radionuclides. The detection and tracing of long-lived radionuclides is being conducted in order to establish base-line values and to study environmental behavior. This paper describes detection and measurement techniques and summarizes current measurement results

  16. Sampling strategy to develop a primary core collection of apple ...

    African Journals Online (AJOL)

    PRECIOUS

    2010-01-11

    Jan 11, 2010 ... Physiology and Molecular Biology for Fruit, Tree, Beijing 100193, China. ... analyzed on genetic diversity to ensure their represen- .... strategy, cluster and random sampling. .... on isozyme data―A simulation study, Theor.

  17. Apollo Lunar Sample Photographs: Digitizing the Moon Rock Collection

    Science.gov (United States)

    Lofgren, Gary E.; Todd, Nancy S.; Runco, S. K.; Stefanov, W. L.

    2011-01-01

    The Acquisition and Curation Office at JSC has undertaken a 4-year data restoration project effort for the lunar science community funded by the LASER program (Lunar Advanced Science and Exploration Research) to digitize photographs of the Apollo lunar rock samples and create high resolution digital images. These sample photographs are not easily accessible outside of JSC, and currently exist only on degradable film in the Curation Data Storage Facility

  18. Sedimentary characteristics of samples collected from some submarine canyons

    NARCIS (Netherlands)

    Bouma, Arnold H.

    Oriented rectangular cores of 20.3 × 30.5 cm and 45.7 cm high have been collected in a number of submarine canyons off southern California (U.S.A.) and off the southern tip of Baja California (Mexico) for a detailed study of their sedimentary structures. By applying several methods, mainly X-ray

  19. Evaluation of standard methods for collecting and processing fuel moisture samples

    Science.gov (United States)

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  20. An Environmentally Friendly, Cost-Effective Determination of Lead in Environmental Samples Using Anodic Stripping Voltammetry

    Science.gov (United States)

    Goldcamp, Michael J.; Underwood, Melinda N.; Cloud, Joshua L.; Harshman, Sean

    2008-01-01

    Contamination of the environment with heavy metals such as lead presents many health risks. Simple, effective, and field-portable methods for the measurement of toxic metals in environmental samples are vital tools for evaluating the risks that these contaminants pose. This article describes the use of new developments in anodic stripping…

  1. Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

    Science.gov (United States)

    McCubbin, F. M.; Allton, J. H.; Evans, C. A.; Fries, M. D.; Nakamura-Messenger, K.; Righter, K.; Zeigler, R. A.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "...curation of all extra-terrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "...documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the past, present, and future activities of the NASA Curation Office.

  2. Determination of 241Am and 244Cm in environmental samples

    International Nuclear Information System (INIS)

    Bonino, N.O.; Grinman, A.D.R.; Serdeiro, N.H.

    1998-01-01

    The present technique describes a method to separate, purify and measure low levels of americium and curium in different environmental samples such as sediments, soils, water, vegetables, and air filters. The determination of radionuclides in theses environmental matrices have analytical problems, since a simple method doesn't exist for the purification, which is indispensable for its later measuring alpha spectrometry. The developed technique consist on taking an aliquot of the sample to analyze, to add tracer as americium 243 and curium 242, and to dissolve the matrix in a such way to have a clear solution. For the isolation of the americium and curium of the other actinides ar used as separation techniques: precipitation with Fe 3+ , anionic and cationic exchange, and extraction with a appropriate organic solvent. The purification of the americium and curium is followed by the electrodeposition habitually used. The measurement is carried out by alpha spectrometry with a detector of implanted ion. The detection limit for this techniques is of 0,002 Bq/l or 0,2 mBq in the case of filters. (author)

  3. 78 FR 78998 - 60-Day Notice of Proposed Information Collection: HUD Environmental Review Online System (HEROS)

    Science.gov (United States)

    2013-12-27

    ... Information Collection: HUD Environmental Review Online System (HEROS) AGENCY: Office of Community Planning... Information Collection Title of Information Collection: HUD Environmental Review Online System (HEROS). OMB... online tool called the HUD Environmental Review Online System (HEROS), which will allow users to complete...

  4. Environmental management in the USSR. Issue 9. Collection of papers

    International Nuclear Information System (INIS)

    Gratsiansky, A.N.

    1991-01-01

    The 9th English-language issue in the series 'Environmental management in the USSR' deals with expert assessment of programmes and relevant governmental decisions on the elimination of consequences of the Chernobyl accident. The collection features the Decision of the USSR Supreme Soviet 'On the Unified Programme for the Elimination of Consequences of the Chernobyl Nuclear Power Plant Accident and the Resultant Situation' adopted on 25 April 1990 and the Report of the Subcommission for State Programmes of the RSFSR, the Ukrainian SSR and the Byelorussian SSR for the Elimination of Consequences of the Chernobyl Nuclear Power Plant Accident in 1990-1995 under the Commission of Experts of the USSR State Planning Committee. To complement the corresponding sections of the Report the collection presents materials on the sociological, socio-psychological and medico-psychological dimensions of the expert appraisal of the general situation existing in the area suffering the consequences of the Chernobyl accident. The present publication has been suggested by the USSR Supreme Soviet Committee for Ecology and Natural Resources Management

  5. Protocol for collecting eDNA samples from streams [Version 2.3

    Science.gov (United States)

    K. J. Carim; T. Wilcox; M. K. Young; K. S. McKelvey; M. K. Schwartz

    2015-01-01

    Throughout the 2014 field season, we had over two dozen biologist throughout the western US collect over 300 samples for eDNA analysis with paired controls. Control samples were collected by filtering 0.5 L of distilled water. No samples had any evidence of field contamination. This method of sampling verifies the cleanliness of the field equipment, as well as the...

  6. Radiometric Data Collection for Environmental Studies in Egypt

    International Nuclear Information System (INIS)

    Abdel Fattah, A.T.; Ramadan, A.A.; Gomaa, M.A.

    2001-01-01

    Radiation protection and monitoring in Egypt covers most fields of activities dealing with radioactivity. Such protection measures necessitate measurements of radiation levels, exposure or contamination whatever they are due to natural or man-made sources. A radiation level in foodstuff samples collected from selected main cities in Egypt was followed for several years after Chernobyl accident. Potassium-40 was found to be the main source of radioactivity. It ranges from 9 Bq/kg for macaroni to about 363 Bq/kg for watercress and broad beans. 137 Cs was found in trace amounts. Radiation measurements were carried out in soil samples collected from sixteen locations all over the country. The natural radiation level of 238 U, 232 Th and 40 K was found to be 7-27 Bq/kg, 3.8-24.4 Bq/kg and 105,7-448.9 Bq/kg respectively. This level was found to be higher in eastern parts of Egypt than in the western parts. Radiological control is precisely undertaken on the entry of food items and certain chemical materials used in industry. Contaminated food, higher than international trading levels, is rejected. Chemical materials containing radioactivity are followed during their uses. The annual effective dose from terrestrial gamma rays was determined for most Egyptian Governorates (106-371 UVv/y). Accordingly,the annual collective dose due to natural background radiation (terrestrial gamma rays and cosmic rays) is about 27,253 Man Sv. As a national need together with international attitude a monitoring network has been established few years after Chernobyl accident. It consists of 42 stations for gamma monitors in air,43 stations in water, 44 stations for beta aerosols, and 15 stations for conventional pollutants. The measured radiation levels are transmitted to control station via digital communication every 15 minutes

  7. Specific activity of 129I in environmental samples

    International Nuclear Information System (INIS)

    Ravi, P.M.; Iyer, M.R.; Bhat, I.S.; Somasundaram, S.; Subramanian, M.S.

    1988-01-01

    129 I finds its way into the environment as a result of man-made nuclear operations. It is also formed by the interaction of cosmic rays with xenon isotopes and spontaneous fission of naturally occurring uranium. 129 I and stable 127 I contents of thyroid, milk, seaweed and aplysia cell samples collected from around a fuel reprocessing plant were estimated by neutron activation analysis method. The annual 129 I intake of an individual works out to be about 0.3 Bq as compared to the natural radioactivity content in human body of about 5000 Bq. (author). 3 tabs

  8. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  9. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  10. A continuous flow from sample collection to data acceptability determination using an automated system

    International Nuclear Information System (INIS)

    Fisk, J.F.; Leasure, C.; Sauter, A.D.

    1993-01-01

    In its role as regulator, EPA is the recipient of enormous reams of analytical data, especially within the Superfund Program. In order to better manage the volume of paper that comes in daily, Superfund has required its laboratories to provide data that is contained on reporting forms to be delivered also on a diskette for uploading into data bases for various purposes, such as checking for contractual compliance, tracking quality assurance parameters, and, ultimately, for reviewing the data by computer. This last area, automated review of the data, has generated programs that are not necessarily appropriate for use by clients other than Superfund. Such is the case with Los Alamos National Laboratory's Environmental Chemistry Group and its emerging subcontractor community, designed to meet the needs of the remedial action program at LANL. LANL is in the process of implementing an automated system that will be used from the planning stage of sample collection to the production of a project-specific report on analytical data quality. Included are electronic scheduling and tracking of samples, data entry, checking and transmission, data assessment and qualification for use, and report generation that will tie the analytical data quality back to the performance criteria defined prior to sample collection. Industry standard products will be used (e.g., ORACLE, Microsoft Excel) to ensure support for users, prevent dependence on proprietary software, and to protect LANL's investment for the future

  11. Evaluation of environmental samples containing heavy hydrocarbon components in environmental forensic investigations

    Energy Technology Data Exchange (ETDEWEB)

    Raia, J.C.; Blakley, C.R.; Fuex, A.N.; Villalanti, D.C.; Fahrenthold, P.D. [Triton Anal Corp, Houston, TX (United States)

    2004-03-01

    This article presents a procedure to evaluate and characterize environmental samples containing mixtures of hydrocarbons over a wide boiling range of materials that include fuels and other products used in commerce. The range of the method extends to the higher boiling and heavier molecular weight hydrocarbon products in the range of motor oil, bunker fuel, and heavier residue materials. The procedure uses the analytical laboratory technique of high-temperature simulated distillation along with mathematical regression of the analytical data to estimate the relative contribution of individual products in mixtures of hydrocarbons present in environmental samples. An analytical technique to determine hydrocarbon-type distributions by gas chromatography-mass spectrometry with nitric oxide ionization spectrometry evaluation is also presented. This type of analysis allows complex hydrocarbon mixtures to be classified by their chemical composition, or types of hydrocarbons that include paraffins, cycloparaffins, monoaromatics, and polycyclic aromatic hydrocarbons. Characteristic hydrocarbon patterns for example, in the relative distribution of polycyclic aromatic hydrocarbons are valuable for determining the potential origin of materials present in environmental samples. These methods provide quantitative data for hydrocarbon components in mixtures as a function of boiling range and 'hydrocarbon fingerprints' of the types of materials present. This information is valuable in assessing environmental impacts of hydrocarbons at contaminated sites and establishing the liabilities and cost allocations for responsible parties.

  12. Acceptability of self-collected versus provider-collected sampling for HPV DNA testing among women in rural El Salvador.

    Science.gov (United States)

    Rosenbaum, Alan J; Gage, Julia C; Alfaro, Karla M; Ditzian, Lauren R; Maza, Mauricio; Scarinci, Isabel C; Felix, Juan C; Castle, Philip E; Villalta, Sofia; Miranda, Esmeralda; Cremer, Miriam L

    2014-08-01

    To determine the acceptability of self-collected versus provider-collected sampling among women participating in public sector HPV-based cervical cancer screening in El Salvador. Two thousand women aged 30-49 years underwent self-collected and provider-collected sampling with careHPV between October 2012 and March 2013 (Qiagen, Gaithersburg, MD, USA). After sample collection, a random sample of women (n=518) were asked about their experience. Participants were questioned regarding sampling method preference, previous cervical cancer screening, HPV and cervical cancer knowledge, HPV risk factors, and demographic information. All 518 women approached to participate in this questionnaire study agreed and were enrolled, 27.8% (142 of 511 responding) of whom had not received cervical cancer screening within the past 3 years and were considered under-screened. Overall, 38.8% (n=201) preferred self-collection and 31.9% (n=165) preferred provider collection. Self-collection preference was associated with prior tubal ligation, HPV knowledge, future self-sampling preference, and future home-screening preference (P<0.05). Reasons for self-collection preference included privacy/embarrassment, ease, and less pain; reasons cited for provider-collection preference were result accuracy and provider knowledge/experience. Self-sampling was found to be acceptable, therefore screening programs could consider offering this option either in the clinic or at home. Self-sampling at home may increase coverage in low-resource countries and reduce the burden that screening places upon clinical infrastructure. Copyright © 2014 International Federation of Gynecology and Obstetrics. All rights reserved.

  13. The role of NAA in the environmental studies. Quantitative determination of heavy metals pollutant on environmental samples

    International Nuclear Information System (INIS)

    Sutisna; Yusuf, Saeful; Fisli, Adel; Rukihati; Wardhani, Sri; Th Rina M

    2003-01-01

    The neutron activation analysis technique was applied in the elemental analysis of environmental samples to solve an environmental pollution problem. We focused our study in the analysis of heavy metal which has potentially become a pollutant. The environmental samples analyzed were some water, sediment and an air particulate matter. The tap water sample was collected from five samplings points located at region of Serpong and Muria. Meanwhile the river water samples were taken from five samplings points of Ciliwung River. Eight samplings points of Cisadane river estuary located at Tanjung Burung were selected to collect sediment samples. Air particulate samples were collected from Jakarta Metropolitan and Serpong using high volume air sampler. Trace elements analyses of water samples were done using a combination of INAA and pre-concentration stage prior irradiation. All samples were irradiated at GA. Siwabessy reactor located at Serpong using a thermal neutron flux of about 10 12 n.cm -2 .sec -1 . After cooling time, the samples irradiated were counted by a high resolution HPGe detector coupled to a multichannel analyzer. The quantitative analyses have been done using a comparative method to a fresh laboratory standard and we used some standard references materials to validate our analytical result. The obtained result from the tap water analysis show that the elements of As, Cr, Co, Cd, Mn, Sb and Zn could be determine quantitatively and they have a concentration range from about 0.02 μg/L to 103.9 μg/L. The analysis result of Ciliwung river water samples show that elements of Ag, As, Co, Cu, Fe, Hg, Mn, V and Zn are present in the range of 2.4 μg/L to about 1365.8 μg/L. Meanwhile some important elements were obtained in the sediments samples taken from Cisadane River estuary such as Ce (40.4 - 63.6 mg/kg), Co (15.2 - 40.2 mg/kg), Cr (21.6 - 57.8 mg/kg), Eu (1.2 - 1.8 mg/kg), Fe (7.0 - 16.8 mg/kg), Mn (887 - 1810 mg/kg) and V (160 - 558 mg/kg). Finally the

  14. The role of NAA in the environmental studies. Quantitative determination of heavy metals pollutant on environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Sutisna; Yusuf, Saeful; Fisli, Adel; Rukihati; Wardhani, Sri; Th Rina M [National Nuclear Energy Agency of Indonesia, Kawasan Puspiptek, Serpong (Indonesia)

    2003-03-01

    The neutron activation analysis technique was applied in the elemental analysis of environmental samples to solve an environmental pollution problem. We focused our study in the analysis of heavy metal which has potentially become a pollutant. The environmental samples analyzed were some water, sediment and an air particulate matter. The tap water sample was collected from five samplings points located at region of Serpong and Muria. Meanwhile the river water samples were taken from five samplings points of Ciliwung River. Eight samplings points of Cisadane river estuary located at Tanjung Burung were selected to collect sediment samples. Air particulate samples were collected from Jakarta Metropolitan and Serpong using high volume air sampler. Trace elements analyses of water samples were done using a combination of INAA and pre-concentration stage prior irradiation. All samples were irradiated at GA. Siwabessy reactor located at Serpong using a thermal neutron flux of about 10{sup 12} n.cm{sup -2}.sec{sup -1}. After cooling time, the samples irradiated were counted by a high resolution HPGe detector coupled to a multichannel analyzer. The quantitative analyses have been done using a comparative method to a fresh laboratory standard and we used some standard references materials to validate our analytical result. The obtained result from the tap water analysis show that the elements of As, Cr, Co, Cd, Mn, Sb and Zn could be determine quantitatively and they have a concentration range from about 0.02 {mu}g/L to 103.9 {mu}g/L. The analysis result of Ciliwung river water samples show that elements of Ag, As, Co, Cu, Fe, Hg, Mn, V and Zn are present in the range of 2.4 {mu}g/L to about 1365.8 {mu}g/L. Meanwhile some important elements were obtained in the sediments samples taken from Cisadane River estuary such as Ce (40.4 - 63.6 mg/kg), Co (15.2 - 40.2 mg/kg), Cr (21.6 - 57.8 mg/kg), Eu (1.2 - 1.8 mg/kg), Fe (7.0 - 16.8 mg/kg), Mn (887 - 1810 mg/kg) and V (160 - 558

  15. Equipment for collecting samples of radioactive solutions; Installation de prelevements d'echantillons de solutions radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-12-03

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described.

  16. Milk samples collected with filter paper for progesterone radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Jiahua, Zhang; Guoxia, Geng; Huaiyu, Zhang

    1985-09-01

    The cow milk was collected with filter paper treated with ethanol during eastrus-day (0 day) and 22th and 24th day after mating. Then it was dried and stored in room temprature until analysis for progesterone by means of radioimmunoassay. The sensitivity is 13.62 pg/bule (n = 4), the coefficients of variation within a group and between groups are 8.8% (n = 10) and 16.65% (n = 8) respectively, and the recovery is 91.23% (n = 4). The average progesterone level for 22th and 24th day in the pregnant cows (6.28 +- 1.28 ng/ml) was much higher than that in the non-pregnant cow (2.00 +- 1.18 ng/ml), the difference being significant (P < 0.001). The judgement based on progesterone level (5 pregnant and 5 non-pregnant cows) faily agreed with the clinical diagnosis.

  17. Separation Techniques for Quantification of Radionuclides in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Dusan Galanda

    2009-01-01

    Full Text Available The reliable and quantitative measurement of radionuclides is important in order to determine environmental quality and radiation safety, and to monitor regulatory compliance. We examined soil samples from Podunajske Biskupice, near the city of Bratislava in the Slovak Republic, for the presence of several natural (238U, 232Th, 40K and anthropogenic (137Cs, 90Sr, 239Pu, 240Pu, 241Am radionuclides. The area is adjacent to a refinery and hazardous waste processing center, as well as the municipal incinerator plant, and so might possess an unusually high level of ecotoxic metals. We found that the levels of both naturally occurring and anthropogenic radionuclides fell within the expected ranges, indicating that these facilities pose no radiological threat to the local environment. During the course of our analysis, we modified existing techniques in order to allow us to handle the unusually large and complex samples that were needed to determine the levels of 239Pu, 240Pu, and 241Am activity. We also rated three commercial techniques for the separation of 90Sr from aqueous solutions and found that two of them, AnaLig Sr-01 and Empore Extraction Disks, were suitable for the quantitative and reliable separation of 90Sr, while the third, Sr-Spec Resin, was less so. The main criterion in evaluating these methods was the chemical recovery of 90Sr, which was less than we had expected. We also considered speed of separation and additional steps needed to prepare the sample for separation.

  18. Radioactive contamination of the environmental samples in Hanoi in 1989

    International Nuclear Information System (INIS)

    Dang Huy Uyen; Bui Van Loat; Dang Phuong Nam; Cao Anh Duc; Pham Quang Dien; Nguyen Hao Quang

    1990-01-01

    More than 30 environmental samples from soil, paddy, rice, fruits, vegetables and beans, sesame, tea, bananas, fishes at Hanoi markets in 1989 were analysed by gamma ray spectrometry with the low background system for studying natural and artificial radioactive elements. Among several samples from Hanoi in such kind as cultivated soils, tea, dried bamboo shoots, isotope Cs 137 that used be generated from nuclear explosives was found with contents (30 - 1000) x 10 -5 Bq/g; Cs 137 contents in Japanese rice (0.4 - 3) x 10 -5 Bq/g. Cs 137 is radioactive so Cs 137 contents in Vietnamese rice are 300 times higher than Cs 137 contents in Japanese rice but they are hundred times lower than international standard. Among vegetables, fruits, shrimps, fishes in Hanoi markets, artificial isotopes were not found and natural isotopes were few. Even radioactive daughter and granddaughter in uranium series in potatoes were not found. In some samples K 40 was also appeared, for example in cultivated soils (0.78 Bq/g), in dried bamboo shoots (0.73 Bq/g). (author). 2 refs., 3 figs

  19. Recent tritium levels in environmental waters collected at the drainage basin of Changjiang (Yangtze River)

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Osamu; Nakagawa, Takao; Hashimoto, Tetsuo [Niigata Univ. (Japan)

    1989-11-01

    This paper reports tritium levels in environmental waters in the China in comparison with those in Japan. Environmental water samples were collected in October-November 1987 from the drainage basin of Changjiang from Sichuan through Hubei districts. Tritium levels were 0.22 Bq/l-6.73 Bq/l (an average, 3.09{plus minus}1.18 Bq/l) in 50 ground water samples; 3.40 Bq/l-3.81 Bq/l (an average, 3.71{plus minus}0.81 Bq/l) in four river samples collected from the main course of the Changjiang River; 1.74 Bq/l-5.40 Bq/l (an average, 3.14{plus minus}1.52 Bq/l) in four river samples collected from the tributary river; and 0.63 Bq/l and 1.78 Bq/l in precipitation samples. Environmental waters contained a large quantity of Ca{sup 2+} and Mg{sup 2+} ions, irrespective of river and ground water samples. In comparing tritium levels in environmental waters in the China and Japan, tritium levels were higher in the ground water influenced by a landslide in the China than Japan. Tritium levels in precipitations collected from the drainage basin of the Changjiang were similar to those in Niigata (Japan), 0.63{plus minus}0.26 Bq/l and 1.78{plus minus}0.26 Bq/l vs 0.53{plus minus}0.36 Bq/l - 2.17{plus minus}0.40 Bq/l. The concentrations of Ca{sup 2+}, Mg{sup 2+}, and HCO{sub 3}{sup -} were higher in the Changjiang River (4 water samples) than the river waters, including the Shinano River in Japan. The concentrations of Na{sup +} and Cl{sup -} were higher in the Changjiang River than the average concentrations in the Japanese rivers, but lower than the Shinano River (Japan). A small quantity of precipitations and width of the Changjiang River, as well as nuclear explosion test performed up to 1980, seem to influence higher tritium levels in the Changjiang than those in Japan. (N.K.).

  20. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Science.gov (United States)

    2010-07-01

    ...) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling To Verify Completion of Self... cleanup verification conducted in accordance with § 761.61(a)(6), follow the procedures in paragraph (b... verification conducted in accordance with § 761.61(a)(6), follow the procedures in this section for locating...

  1. The Autism Simplex Collection : an international, expertly phenotyped autism sample for genetic and phenotypic analyses

    OpenAIRE

    Buxbaum, Joseph D.; Bolshakova, Nadia; Brownfeld, Jessica M.; Anney, Richard J. L.; Bender, Patrick; Bernier, Raphael; Cook, Edwin H.; Coon, Hilary; Cuccaro, Michael L.; Freitag, Christine M.; Hallmayer, Joachim; Geschwind, Daniel H.; Klauck, Sabine M.; Nurnberger, John I.; Oliveira, Guiomar

    2014-01-01

    Background: There is an urgent need for expanding and enhancing autism spectrum disorder (ASD) samples, in order to better understand causes of ASD. Methods: In a unique public-private partnership, 13 sites with extensive experience in both the assessment and diagnosis of ASD embarked on an ambitious, 2-year program to collect samples for genetic and phenotypic research and begin analyses on these samples. The program was called The Autism Simplex Collection (TASC). TASC sample collection ...

  2. Analysis of selected phytotoxins and mycotoxins in environmental samples.

    Science.gov (United States)

    Hoerger, Corinne C; Schenzel, Judith; Strobel, Bjarne W; Bucheli, Thomas D

    2009-11-01

    Natural toxins such as phytotoxins and mycotoxins have been studied in food and feed for decades, but little attention has yet been paid to their occurrence in the environment. Because of increasing awareness of the presence and potential relevance of micropollutants in the environment, phytotoxins and mycotoxins should be considered and investigated as part of the chemical cocktail in natural samples. Here, we compile chemical analytical methods to determine important phytotoxins (i.e. phenolic acids, quinones, benzoxazinones, terpenoids, glycoalkaloids, glucosinolates, isothiocyanates, phytosterols, flavonoids, coumestans, lignans, and chalcones) and mycotoxins (i.e. resorcyclic acid lactones, trichothecenes, fumonisins, and aflatoxins) in environmentally relevant matrices such as surface water, waste water-treatment plant influent and effluent, soil, sediment, manure, and sewage sludge. The main problems encountered in many of the reviewed methods were the frequent unavailability of suitable internal standards (especially isotope-labelled analogues) and often absent or fragmentary method optimization and validation.

  3. Radioactive kryptonates in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    The term ''radioactive Kryptonates'' is used for substances into which atoms or ions of the radioactive nuclide 85 Kr are incorporated. The basis of the use of radioactive Kryptonates in analytical chemistry is that during a chemical reaction the crystalline lattice of the kryptonated carrier is destroyed, the carrier consumed, and the radioactive krypton released (radio-release method). Analysis can be made with a calibration curve or by comparison with a standard. Radio-release methods with the aid of radioactive Kryptonates as analytical reagents are very useful for the analysis of environmental samples, e.g. for the determination of air pollutants (ozone, sulphur dioxide, fluorine, hydrogen fluoride, mercury); and water pollutants (oxygen, dichromate, vanadium, hydrochloric acid, sulphur dioxide). (author)

  4. Gamma-spectrometry of extended sources for analysing environmental samples

    International Nuclear Information System (INIS)

    Jarosievitz, B.

    1996-01-01

    Measurements of the environmental activity concentration by gamma spectrometers require the determination of the full-energy-peak efficiency as a function of photon energy over the detector range. This can be done by experiments or by calculation. For simple cases, experiments are straightforward, but if the decay scheme is complex, cascade effects modify detection efficiency. Also, actual detection efficiency depends on the detection geometry. All these effects are treated as corrections or modifications of the simple value cases which are especially relevant when applied to large volume of environmental samples. In this thesis calculations are made, using the GEANT MC program, for realistic experimental situations that have been performed, and these calculations are validated. The calculational and experimental results have been compared, and if it proves to be satisfactory, the results can be relied on even for cases when no direct experimental observation is possible. The general problems of gamma spectroscopy and correction problems are discussed. The two main tools, the experimental setup and the simulation program are described. A careful checking of the simulation results and the consequences are presented. (R.P.)

  5. Determination of technetium-99 in environmental and radioactive waste samples

    International Nuclear Information System (INIS)

    Ferencova, M.; Peter Tkac, P.

    2007-01-01

    Technetium is known for its high mobility in a soil-water system in non-reducing aerobic condition and also high bio-availability for plants, because the most stable form of technetium in natural surface environment is pertechnetate which is highly soluble. The chemical form of technetium changes with environmental conditions. Concentration of technetium in the environment is very low, therefore many separation steps are needed for technetium determination. It has been developed a method for the routine determination of technetium-99 from environmental matrices and radioactive wastes using technetium-99m as an internal yield monitor. Technetium-99 is extracted from the soil samples with nitric acid. Many contaminants are co-precipitated with ferric hydroxide and technetium in the supernatant is pre-concentrated and further purified using anion exchange chromatography. Final separation of technetium was achieved by extraction with tetraphenylarsonium chloride in chloroform from sulphuric acid or pure water. The chemical yield is determined through the measurement of technetium-99m by scintillation counting system and the technetium-99 activity is measured using proportional counter after decay of the technetium-99m activity. Typical recoveries for this method are in the order 50-60 % (authors)

  6. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    International Nuclear Information System (INIS)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy's (DOE's) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples

  7. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy`s (DOE`s) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples.

  8. [Detection of Cryptospordium spp. in environmental water samples by FTA-PCR].

    Science.gov (United States)

    Zhang, Xiao-Ping; Zhu, Qian; He, Yan-Yan; Jiang, Li; Jiang, Shou-Fu

    2011-02-01

    To establish a FTA-polymeras chain reaction (FTA-PCR) method in detection of Cryptospordium spp. in different sources of water. The semi automated immunomagnetic separation (IMS) of Cryptospordium oocysts in environmental water samples was performed firstly, and then genomic DNA of Cryptospordium oocysts was extracted by FTA filters disk. Oligonucleotide primers were designed based on the DNA fragment of the 18 S rRNA gene from C. parvum. Plate DNA was amplified with primers in PCR. The control DNA samples from Toxoplasma gondii,Sarcocystis suihominis, Echinococcus granulosus, and Clonorchis sinensis were amplified simultaneously. All PCR products were detected by agar electrophoresis dyed with ethidium bromide. The 446 bp fragment of DNA was detected in all samples of C. parvum, C. andersoni, and C. baileyi, while it was not detected in control groups in laboratory. No positive samples were found from 10 samples collected from tape water in 5 districts of Shanghai City by FTA-PCR. Nine positive samples were detected totally from 70 different environmental water samples, there were 0 out of 15 samples from the source of tape water, 2 out of 25 from the Huangpu River, 5 out of 15 from rivers around the animal farmers, 1 out of 9 from output water of contaminating water treatment factory, 1 out of 6 from the out gate of living contaminating water. The 446 bp fragment was detected from all the amplified positive water samples. FTA-PCR is an efficient method for gene detection of Cryptospordium oocysts, which could be used in detection of environmental water samples. The contamination degree of Cryptospordium oocysts in the river water around animal farms is high.

  9. Conformity Assessment in Nuclear Material and Environmental Sample Analysis

    International Nuclear Information System (INIS)

    Aregbe, Y.; Jakopic, R.; Richter, S.; Venchiarutti, C.

    2015-01-01

    Safeguards conclusions are based to a large extent on comparison of measurement results between operator and safeguards laboratories. Measurement results must state traceability and uncertainties to be comparable. Recent workshops held at the IAEA and in the frame of the European Safeguards Research and Development Association (ESARDA), reviewed different approaches for Nuclear Material Balance Evaluation (MBE). Among those, the ''bottom-up'' approach requires assessment of operators and safeguards laboratories measurement systems and capabilities. Therefore, inter-laboratory comparisons (ILCs) with independent reference values provided for decades by JRC-IRMM, CEA/CETAMA and US DOE are instrumental to shed light on the current state of practice in measurements of nuclear material and environmental swipe samples. Participating laboratories are requested to report the measurement results with associated uncertainties, and have the possibility to benchmark those results against independent and traceable reference values. The measurement capability of both the IAEA Network of Analytical Laboratories (NWAL) and the nuclear operator's analytical services participating in ILCs can be assessed against the independent reference values as well as against internationally agreed quality goals, in compliance with ISO 13528:2005. The quality goals for nuclear material analysis are the relative combined standard uncertainties listed in the ITV2010. Concerning environmental swipe sample analysis, the IAEA defined measurement quality goals applied in conformity assessment. The paper reports examples from relevant inter-laboratory comparisons, looking at laboratory performance according to the purpose of the measurement and the possible use of the result in line with the IUPAC International Harmonized Protocol. Tendencies of laboratories to either overestimate and/or underestimate uncertainties are discussed using straightforward graphical tools to evaluate

  10. Impact of sample size on principal component analysis ordination of an environmental data set: effects on eigenstructure

    Directory of Open Access Journals (Sweden)

    Shaukat S. Shahid

    2016-06-01

    Full Text Available In this study, we used bootstrap simulation of a real data set to investigate the impact of sample size (N = 20, 30, 40 and 50 on the eigenvalues and eigenvectors resulting from principal component analysis (PCA. For each sample size, 100 bootstrap samples were drawn from environmental data matrix pertaining to water quality variables (p = 22 of a small data set comprising of 55 samples (stations from where water samples were collected. Because in ecology and environmental sciences the data sets are invariably small owing to high cost of collection and analysis of samples, we restricted our study to relatively small sample sizes. We focused attention on comparison of first 6 eigenvectors and first 10 eigenvalues. Data sets were compared using agglomerative cluster analysis using Ward’s method that does not require any stringent distributional assumptions.

  11. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    Science.gov (United States)

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of

  12. PIXE analysis of marine environmental samples from the Pacific Ocean

    International Nuclear Information System (INIS)

    Miyake, Hiroshi; Matsuda, Yasuhiro; Shitashima, Kiminori; Tsubota, Hiroyuki.

    1990-01-01

    Aerosol samples from the western North Pacific Ocean are collected during a cruise of R/V Hakuhomaru from Japan to Hawaii and they are analyzed by PIXE (particle induced X-ray emission). Concentrations of radon daughters are measured with CR-39 track detectors mounted on the impactor to estimate the transport time of air mass from the Asian Continent. Distributions of particulate element concentrations clearly demonstrate the influence of the westerlies. Strong correlations are observed between fine sulphur concentrations and those of heavy metals such as Fe and Zn. Vertical profiles of heavy metal elements contained in marine particulates are also investigated at a trench in the Pacific Ocean and basins in the Japan Sea. Particulate element concentrations determined by PIXE agree well with those determined by chemical analysis of filtered/total water. Remarkable changes in depth profiles of particulate manganese are observed at the trench, which suggest horizontal transport of marine particulates from the trench wall. (N.K.)

  13. Determination of 90Sr in environmental samples with resonance ionization spectroscopy in collinear geometry

    International Nuclear Information System (INIS)

    Zimmer, K.; Stenner, J.; Kluge, H.J.; Lantzsch, J.; Monz, L.; Otten, E.W.; Passler, G.; Schwalbach, R.; Schwarz, M.; Stevens, H.; Wendt, K.; Herrmann, G.; Niess, S.; Trautmann, N.; Walter, K.; Bushaw, B.A.

    1994-01-01

    A new, fast technique for trace analysis of the radioactive isotopes 89 Sr and 90 Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the 90 Sr content in ∼ 870 m 3 air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of 90 Sr was measured to be 1.4 mBq per m 3 , corresponding to 1.6 x 10 9 atoms of 90 Sr per sample. This value is in good agreement with the results of radiochemical measurements. (orig.)

  14. Determination of [sup 90]Sr in environmental samples with resonance ionization spectroscopy in collinear geometry

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, K. (Inst. fuer Physik, Univ. Mainz (Germany)); Stenner, J. (Inst. fuer Physik, Univ. Mainz (Germany)); Kluge, H.J. (Inst. fuer Physik, Univ. Mainz (Germany)); Lantzsch, J. (Inst. fuer Physik, Univ. Mainz (Germany)); Monz, L. (Inst. fuer Physik, Univ. Mainz (Germany)); Otten, E.W. (Inst. fuer Physik, Univ. Mainz (Germany)); Passler, G. (Inst. fuer Physik, Univ. Mainz (Germany)); Schwalbach, R. (Inst. fuer Physik, Univ. Mainz (Germany)); Schwarz, M. (Inst. fuer Physik, Univ. Mainz (Germany)); Stevens, H. (Inst. fuer Physik, Univ. Mainz (Germany)); Wendt, K. (Inst. fuer Physik, Univ. Mainz (Germany)); Herrmann, G. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Niess, S. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Trautmann, N. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Walter, K. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Bushaw, B.A. (Pacific Northwest Lab., Richland, WA (United States))

    1994-08-01

    A new, fast technique for trace analysis of the radioactive isotopes [sup 89]Sr and [sup 90]Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the [sup 90]Sr content in [approx] 870 m[sup 3] air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of [sup 90]Sr was measured to be 1.4 mBq per m[sup 3], corresponding to 1.6 x 10[sup 9] atoms of [sup 90]Sr per sample. This value is in good agreement with the results of radiochemical measurements. (orig.)

  15. Modern Trends in Neutron Activation Analysis. Applications to some African Environmental Samples

    International Nuclear Information System (INIS)

    Hassan, A.M.

    2009-01-01

    This review covers the results of several published articles which deal with the modern trends in neutron activation analysis techniques using some of African research reactors for some environmental samples. The samples used have been collected from different areas in Egypt, South Africa, Ghana, Morocco, Nigeria, and Algeria. The neutron irradiation facilities and the advanced detection systems in each country are outlined. The prompt and delayed gamma-rays emitted due to neutron capture have been applied for investigation of the elemental constituents of such samples. Covered applications include exploration, mining, industrial environment, pollution of air, foodstuffs, soils and irrigation water samples. Some of the developed software programmes as well as the modern methods of data analysis are presented. The thermal and epithermal neutron activation analysis techniques have been applied for estimation of major, minor and trace elements in each material. Some of these data are presented with several comments.

  16. Effects of holding time and measurement error on culturing Legionella in environmental water samples.

    Science.gov (United States)

    Flanders, W Dana; Kirkland, Kimberly H; Shelton, Brian G

    2014-10-01

    Outbreaks of Legionnaires' disease require environmental testing of water samples from potentially implicated building water systems to identify the source of exposure. A previous study reports a large impact on Legionella sample results due to shipping and delays in sample processing. Specifically, this same study, without accounting for measurement error, reports more than half of shipped samples tested had Legionella levels that arbitrarily changed up or down by one or more logs, and the authors attribute this result to shipping time. Accordingly, we conducted a study to determine the effects of sample holding/shipping time on Legionella sample results while taking into account measurement error, which has previously not been addressed. We analyzed 159 samples, each split into 16 aliquots, of which one-half (8) were processed promptly after collection. The remaining half (8) were processed the following day to assess impact of holding/shipping time. A total of 2544 samples were analyzed including replicates. After accounting for inherent measurement error, we found that the effect of holding time on observed Legionella counts was small and should have no practical impact on interpretation of results. Holding samples increased the root mean squared error by only about 3-8%. Notably, for only one of 159 samples, did the average of the 8 replicate counts change by 1 log. Thus, our findings do not support the hypothesis of frequent, significant (≥= 1 log10 unit) Legionella colony count changes due to holding. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Comparative evaluation of the US Environmental Protection Agency's and the Oak Ridge Institute for Science and Education's environmental survey and site assessment program field sampling procedures

    International Nuclear Information System (INIS)

    Vitkus, T.J.; Bright, T.L.; Roberts, S.A.

    1997-10-01

    At the request of the U.S. Nuclear Regulatory Commission's (NRC's) Headquarters Office, the Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) compared the documented procedures that the U.S. Environmental Protection Agency (EPA) and ESSAP use for collecting environmental samples. The project objectives were to review both organizations' procedures applicable to collecting various sample matrices, compare the procedures for similarities and differences, and then to evaluate the reason for any identified procedural differences and their potential impact on ESSAP's sample data quality. The procedures reviewed included those for sampling surface and subsurface soil, surface and groundwater, vegetation, air, and removable surface contamination. ESSAP obtained copies of relevant EPA documents and reviewed and prepared a tabulated summary of each applicable procedure. The methods for collecting and handling each type of sample were evaluated for differences, and where these were identified, the significance and effect of the differences on analytical quality were determined. The results of the comparison showed that, overall, the procedures and methods that EPA and ESSAP use for sample collection are very similar. The number of minor differences noted were the result of restrictions or procedures necessary to ensure sample integrity and prevent the introduction of interfering compounds when samples are to be analyzed for chemical parameters. For most radio nuclide analyses, these additional procedures are not necessary. Another item noted was EPA's inclusion of steps that reduce the potential for sample cross-contamination by preparing (dressing) a location prior to collecting a sample or removing a portion of a sample prior to containerization

  18. Salmonella isolated from individual reptiles and environmental samples from terraria in private households in Sweden.

    Science.gov (United States)

    Wikström, Veronica O; Fernström, Lise-Lotte; Melin, Lennart; Boqvist, Sofia

    2014-01-24

    This study investigates Salmonella spp. isolated from privately kept reptiles and from environmental samples such as bedding materials or water from the floor of the enclosures (terraria). It also compares isolation of Salmonella using Modified Semisolid Rappaport-Vassiliadis (MSRV) medium or selective enrichment in Rappaport-Vassiliadis-Soya (RVS) pepton broth. Cloacal swabs or swabs from the cloacal area were collected from 63 individual reptiles belonging to 14 households. All reptiles were from different terraria and from 62 of these, environmental samples were also collected. Sampling were done by the reptile owners according to written instructions and sent by mail immediately after sampling. All but three samples were analyzed within 24 h after collection. Colonies suspected for Salmonella were tested for agglutination and serotyped using the White-Kauffmann-Le Minor scheme. The relative sensitivity (se) and specificity (sp) for MSRV compared with RVS, and the agreement coefficient kappa (κ) were calculated. Salmonella was isolated from 50/63 (80%) terraria, either from the reptiles (31/63; 49%) or from bedding material (39/62; 63%). The most common subspecies was Salmonella enterica subspecies enterica followed by S. enterica subspecies diarizonae. In reptiles, the most common S. enterica subspecies enterica serovars were Java (n = 4) and Fluntern (n = 4), compared with the serovars Tennessee (n = 10) and Fluntern (n = 10) in the environmental samples. The exact same set of Salmonella subspecies and serovars were not isolated from the individual reptiles and the environmental samples from any of the households. Isolation using MSRV yielded more Salmonella isolates 61/113 (54%) than enrichment in RVS 57/125 (46%). The se was 97.9% (95% Confidence Interval 93.9-100), the sp 78.5% (95% CI 68.5-88.5) and the κ 0.74, indicating substantial agreement between the tests. Salmonella can be expected to be present in environments where reptiles are

  19. Radionuclides concentration in marine environmental samples along the coast of Vietnam

    International Nuclear Information System (INIS)

    Nguyen Trong Ngo; Nguyen Thanh Binh; Nguyen Van Phuc; Le Nhu Sieu; Truong Y; Mai Thi Huong; Nguyen Thi Linh; Nguyen Mong Sinh; Phan Son Hai; Le Ngoc Chung; Dang Duc Nhan; Nguyen Quang Long; Nguyen Hao Quang; Tran Tuyet Mai

    2009-01-01

    Studies on radioactivity inventories in environmental samples are necessary as they will serve as baseline data for assessing any environmental impact usage of nuclear-based activities. Approximately 700 data on 238 U, 232 Th, 226 Ra, 90 Sr, 137 Cs, 239,240 Pu activity concentrations in 150 samples i.e. sea water, sediment, fish, mollusc, crustaceans, oyster and weeds samples collected from 7 various locations in Vietnam (Hai Phong, Nghe An, Khanh Hoa, Ninh Thuan, Binh Thuan, Vung Tau, Tien Giang) throughout 1999-2008 are summarised and presented in this paper. Generally, the levels of artificial radionuclides in the studied marine environmental samples are lower as compared to other Asia-Pacific countries while naturally occurred radionuclides activity concentrations obtained were found to be in accordance with respective data from other studies within Pacific region. The radionuclides bioaccumulation factors studied in Red laver and oyster were mostly found to be high; therefore, further reinvestigation should be done for these biota that will be used as bio-fingerprint indicators in monitoring the marine environment from nuclear-based pollutions. The data set obtained from this study is available to the Asia-Pacific Marine Radioactivity Database. (author)

  20. Detection of Chlamydophila psittaci from feral pigeons in environmental samples: problems with currently available techniques.

    Science.gov (United States)

    Geigenfeind, Ila; Haag-Wackernagel, Daniel

    2010-03-01

    Chlamydophila psittaci (Lillie, 1930) Everett et al., 1999, the pathogenic agent of human ornithosis, is widespread in feral pigeon populations and many cases of transmission from feral pigeons to humans have been reported. The aim of the present study was to detect C. psittaci in environmental samples to find out more about possible transmission routes and, therefore, to assess the zoonotic risk for humans. Fecal samples were collected from nest boxes in a feral pigeon loft. Additionally, samples were taken from the feather dust film covering the water surface of public fountains where pigeons regularly bathe. The samples were tested for the presence of chlamydial antigen using an antigen enzyme-linked immunosorbent assay to prove shedding of C. psittaci by feral pigeons. This test detects a genus specific lipopolysaccharide in the outer membrane of the chlamydial bacteria. Samples were tested using the IDEIA PCE Chlamydia Test kit (DakoCytomation) and positive results were verified with IDEIA Chlamydia Blocking Reagents (DakoCytomation). The IDEIA PCE Chlamydia Test yields a high proportion of positive results. However, when IDEIA Chlamydia Blocking was performed, most of the positive results turned out to be negative or could not be interpreted. We conclude that antigen-enzyme-linked immunosorbent assay tests are not suitable for detecting C. psittaci in environmental samples. Previous publications where no blocking test was used should be reconsidered critically. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  1. Technical Note: New methodology for measuring viscosities in small volumes characteristic of environmental chamber particle samples

    Directory of Open Access Journals (Sweden)

    L. Renbaum-Wolff

    2013-01-01

    Full Text Available Herein, a method for the determination of viscosities of small sample volumes is introduced, with important implications for the viscosity determination of particle samples from environmental chambers (used to simulate atmospheric conditions. The amount of sample needed is < 1 μl, and the technique is capable of determining viscosities (η ranging between 10−3 and 103 Pascal seconds (Pa s in samples that cover a range of chemical properties and with real-time relative humidity and temperature control; hence, the technique should be well-suited for determining the viscosities, under atmospherically relevant conditions, of particles collected from environmental chambers. In this technique, supermicron particles are first deposited on an inert hydrophobic substrate. Then, insoluble beads (~1 μm in diameter are embedded in the particles. Next, a flow of gas is introduced over the particles, which generates a shear stress on the particle surfaces. The sample responds to this shear stress by generating internal circulations, which are quantified with an optical microscope by monitoring the movement of the beads. The rate of internal circulation is shown to be a function of particle viscosity but independent of the particle material for a wide range of organic and organic-water samples. A calibration curve is constructed from the experimental data that relates the rate of internal circulation to particle viscosity, and this calibration curve is successfully used to predict viscosities in multicomponent organic mixtures.

  2. Self-collected versus clinician-collected sampling for sexually transmitted infections: a systematic review and meta-analysis protocol.

    Science.gov (United States)

    Taylor, Darlene; Lunny, Carole; Wong, Tom; Gilbert, Mark; Li, Neville; Lester, Richard; Krajden, Mel; Hoang, Linda; Ogilvie, Gina

    2013-10-10

    Three meta-analyses and one systematic review have been conducted on the question of whether self-collected specimens are as accurate as clinician-collected specimens for STI screening. However, these reviews predate 2007 and did not analyze rectal or pharyngeal collection sites. Currently, there is no consensus on which sampling method is the most effective for the diagnosis of genital chlamydia (CT), gonorrhea (GC) or human papillomavirus (HPV) infection. Our meta-analysis aims to be comprehensive in that it will examine the evidence of whether self-collected vaginal, urine, pharyngeal and rectal specimens provide as accurate a clinical diagnosis as clinician-collected samples (reference standard). Eligible studies include both randomized and non-randomized controlled trials, pre- and post-test designs, and controlled observational studies. The databases that will be searched include the Cochrane Database of Systematic Reviews, Web of Science, Database of Abstracts of Reviews of Effects (DARE), EMBASE and PubMed/Medline. Data will be abstracted independently by two reviewers using a standardized pre-tested data abstraction form. Heterogeneity will be assessed using the Q2 test. Sensitivity and specificity estimates with 95% confidence intervals as well as negative and positive likelihood ratios will be pooled and weighted using random effects meta-analysis, if appropriate. A hierarchical summary receiver operating characteristics curve for self-collected specimens will be generated. This synthesis involves a meta-analysis of self-collected samples (urine, vaginal, pharyngeal and rectal swabs) versus clinician-collected samples for the diagnosis of CT, GC and HPV, the most prevalent STIs. Our systematic review will allow patients, clinicians and researchers to determine the diagnostic accuracy of specimens collected by patients compared to those collected by clinicians in the detection of chlamydia, gonorrhea and HPV.

  3. Voltammetric technique, a panacea for analytical examination of environmental samples

    International Nuclear Information System (INIS)

    Zahir, E.; Mohiuddin, S.; Naqvi, I.I.

    2012-01-01

    Voltammetric methods for trace metal analysis in environmental samples of marine origin like mangrove, sediments and shrimps are generally recommended. Three different electro-analytical techniques i.e. polarography, anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (ADSV) have been used. Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ and Mn/sub 2/+ were determined through ASV, Cr/sub 6/+ was analyzed by ADSV and Fe/sub 2/+, Zn/sub 2/+, Ni/sub 2/+ and Co/sub 2/+ were determined through polarography. Out of which pairs of Fe/sub 2/+Zn/sub 2/+ and Ni/sub 2/+Co/sub 2/+ were determined in two separate runs while Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ were analyzed in single run of ASV. Sensitivity and speciation capabilities of voltammetric methods have been employed. Analysis conditions were optimized that includes selection of supporting electrolyte, pH, working electrodes, sweep rate etc. Stripping voltammetry was adopted for analysis at ultra trace levels. Statistical parameters for analytical method development like selectivity factor, interference, repeatability (0.0065-0.130 macro g/g), reproducibility (0.08125-1.625 macro g/g), detection limits (0.032-5.06 macro g/g), limits of quantification (0.081-12.652 macro g/g), sensitivities (5.636-2.15 nA mL macro g-1) etc. were also determined. The percentage recoveries were found in between 95-105% using certified reference materials. Real samples of complex marine environment from Karachi coastline were also analyzed. The standard addition method was employed where any matrix effect was evidenced. (author)

  4. Application of SIMS to the analysis of environmental samples

    International Nuclear Information System (INIS)

    Seyama, Haruhiko

    2003-01-01

    As an example of surface analysis of environmental samples, SIMS was applied to airborne particulates, fish otoliths (a calcareous ear-stone) and biotites (a rock-forming aluminosilicate mineral). Airborne particulates deposited on leaf surface were analyzed directly by fast atom bombardment (FAB)-SIMS using an O 2 primary neutral beam. Some metal elements, such as Pb, of aerosol origin could be detected. Local areas of a thin section of an otolith were analyzed by FAB-SIMS. Line scans and images of secondary ions revealed seasonal periodicity in Sr, Na and K concentrations in the otolith that corresponded to the annual band structure. Surface alteration of acid-treated and naturally weathered biotites was studied by SIMS depth profiling using an O - primary ion. The depth profile of the acid-treated biotite showed the formation of an altered surface layer rich in Si. In contrast a thick altered surface layer was not observed and Al was held on the surface under natural weathering

  5. Methods to maximise recovery of environmental DNA from water samples.

    Directory of Open Access Journals (Sweden)

    Rheyda Hinlo

    Full Text Available The environmental DNA (eDNA method is a detection technique that is rapidly gaining credibility as a sensitive tool useful in the surveillance and monitoring of invasive and threatened species. Because eDNA analysis often deals with small quantities of short and degraded DNA fragments, methods that maximize eDNA recovery are required to increase detectability. In this study, we performed experiments at different stages of the eDNA analysis to show which combinations of methods give the best recovery rate for eDNA. Using Oriental weatherloach (Misgurnus anguillicaudatus as a study species, we show that various combinations of DNA capture, preservation and extraction methods can significantly affect DNA yield. Filtration using cellulose nitrate filter paper preserved in ethanol or stored in a -20°C freezer and extracted with the Qiagen DNeasy kit outperformed other combinations in terms of cost and efficiency of DNA recovery. Our results support the recommendation to filter water samples within 24hours but if this is not possible, our results suggest that refrigeration may be a better option than freezing for short-term storage (i.e., 3-5 days. This information is useful in designing eDNA detection of low-density invasive or threatened species, where small variations in DNA recovery can signify the difference between detection success or failure.

  6. Collection and analysis of environmental radiation data using a desktop computer

    International Nuclear Information System (INIS)

    Gogolak, C.V.

    1982-04-01

    A portable instrumentation sytem using a Hewlett-Packard HP-9825 desktop computer for the collection and analysis of environmental radiation data is described. Procedures for the transmission of data between the HP-9825 and various nuclear counters are given together with a description of the necessary hardware and software. Complete programs for the analysis of Ge(Li) and NaI(Tl) gamma-ray spectra, high pressure ionization chamber monitor data, 86 Kr monitor data and air filter sample alpha particle activity measurements are presented. Some utility programs, intended to increase system flexibility, are included

  7. Free water {sup 3}H concentration in diet samples collected during 1969-88 in Akita, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Hisamatsu, S. [Institute for Environmental Sciences, Rokkasho, Aomori (Japan); Inoue, Y.; Miyamoto, K. [National Inst. of Radiological Sciences, Chiba (Japan); Takizawa, Y. [National Institute for Minamata Disease, Minamata, Kumamoto (Japan)

    2000-05-01

    Fallout {sup 3}H concentrations in diet samples collected during 1969-88 in Akita Prefecture are reported in this paper. Since {sup 3}H is a potential nuclear fuel for fusion reactors in future, its environmental behavior is important for dose assessment of released {sup 3}H from the plants. Tritium in foods is classified into two types; free water {sup 3}H (FWT) and organically-bound {sup 3}H (OBT). The FWT is practically separated by means of freeze-drying, while the OBT is measured with water sample collected by combustion of dried sample. The OBT concentrations in foods and human tissue samples were reported for {sup 3}H originating from nuclear weapon fallout. We already published {sup 3}H concentrations in diet samples collected in Akita City during 1985-88. Although results for the samples collected in U.S.A. and European countries in the 1970s showed higher specific activity of OBT than FWT, our recent results in Japan indicate almost the same specific activity between them. Since the measurements for the samples in 1960s and 1970s are important to understand the long-term movement of {sup 3}H in the environment, we have searched old diet samples. Recently, diet samples collected in Akita Prefecture during 1969-80 were found and obtained for {sup 3}H analysis. The samples were originally gathered for nutrition survey programs and consisted of duplicate diet samples for 1 day from 10-30 persons. Food samples excluding boiled rice which is the staple food was homogenized by electric mixers after adding tap water. Then, the food and the boiled rice samples were stored in a refrigerator at -20degC. Free water in the samples was collected with lyophilization, then {sup 3}H in the water sample was measured after purification with low-level liquid scintillation counters. The free water {sup 3}H concentrations were measured for 57 diet samples (dish excluding boiled rice) and 17 boiled rice samples. The free water {sup 3}H concentrations in diet and rice samples

  8. Speciation of Cr(VI) in environmental samples in the vicinity of the ferrochrome smelter

    Energy Technology Data Exchange (ETDEWEB)

    Sedumedi, Hilda N. [Department of Chemistry, Tshwane University of Technology, P.O. Box 56208, Arcadia, 0007, Pretoria (South Africa); Mandiwana, Khakhathi L., E-mail: MandiwanaKL@tut.ac.za [Department of Chemistry, Tshwane University of Technology, P.O. Box 56208, Arcadia, 0007, Pretoria (South Africa); Ngobeni, Prince; Panichev, Nikolay [Department of Chemistry, Tshwane University of Technology, P.O. Box 56208, Arcadia, 0007, Pretoria (South Africa)

    2009-12-30

    The impact of ferrochrome smelter on the contamination of its environment with toxic hexavalent chromium, Cr(VI), was assessed by analyzing smelter dusts, soil, grass and tree barks. For the separation of Cr(VI) from Cr(III), solid samples were treated with 0.1 M Na{sub 2}CO{sub 3} and filtered through hydrophilic PDVF 0.45 {mu}m filter prior to the determination of Cr(VI) by electrothermal atomic absorption spectrometry (ET-AAS). Ferrochrome smelter dust was found to contain significant levels of Cr(VI), viz. 43.5 {mu}g g{sup -1} (cyclone dust), 2710 {mu}g g{sup -1} (fine dust), and 7800 {mu}g g{sup -1} (slimes dust) which exceeded the maximum acceptable risk concentration (20 {mu}g g{sup -1}). The concentration of Cr(VI) in environmental samples of grass (3.4 {+-} 0.2), soil (7.7 {+-} 0.2), and tree bark (11.8 {+-} 1.2) collected in the vicinity of the chrome smelter were higher as compared with the same kind of samples collected from uncontaminated area. The results of the investigation show that ferrochrome smelter is a source of environmental pollution with contamination factors of Cr(VI) ranging between 10 and 50.

  9. Speciation of Cr(VI) in environmental samples in the vicinity of the ferrochrome smelter.

    Science.gov (United States)

    Sedumedi, Hilda N; Mandiwana, Khakhathi L; Ngobeni, Prince; Panichev, Nikolay

    2009-12-30

    The impact of ferrochrome smelter on the contamination of its environment with toxic hexavalent chromium, Cr(VI), was assessed by analyzing smelter dusts, soil, grass and tree barks. For the separation of Cr(VI) from Cr(III), solid samples were treated with 0.1M Na(2)CO(3) and filtered through hydrophilic PDVF 0.45 microm filter prior to the determination of Cr(VI) by electrothermal atomic absorption spectrometry (ET-AAS). Ferrochrome smelter dust was found to contain significant levels of Cr(VI), viz. 43.5 microg g(-1) (cyclone dust), 2710 microg g(-1) (fine dust), and 7800 microg g(-1) (slimes dust) which exceeded the maximum acceptable risk concentration (20 microg g(-1)). The concentration of Cr(VI) in environmental samples of grass (3.4+/-0.2), soil (7.7+/-0.2), and tree bark (11.8+/-1.2) collected in the vicinity of the chrome smelter were higher as compared with the same kind of samples collected from uncontaminated area. The results of the investigation show that ferrochrome smelter is a source of environmental pollution with contamination factors of Cr(VI) ranging between 10 and 50.

  10. Speciation of Cr(VI) in environmental samples in the vicinity of the ferrochrome smelter

    International Nuclear Information System (INIS)

    Sedumedi, Hilda N.; Mandiwana, Khakhathi L.; Ngobeni, Prince; Panichev, Nikolay

    2009-01-01

    The impact of ferrochrome smelter on the contamination of its environment with toxic hexavalent chromium, Cr(VI), was assessed by analyzing smelter dusts, soil, grass and tree barks. For the separation of Cr(VI) from Cr(III), solid samples were treated with 0.1 M Na 2 CO 3 and filtered through hydrophilic PDVF 0.45 μm filter prior to the determination of Cr(VI) by electrothermal atomic absorption spectrometry (ET-AAS). Ferrochrome smelter dust was found to contain significant levels of Cr(VI), viz. 43.5 μg g -1 (cyclone dust), 2710 μg g -1 (fine dust), and 7800 μg g -1 (slimes dust) which exceeded the maximum acceptable risk concentration (20 μg g -1 ). The concentration of Cr(VI) in environmental samples of grass (3.4 ± 0.2), soil (7.7 ± 0.2), and tree bark (11.8 ± 1.2) collected in the vicinity of the chrome smelter were higher as compared with the same kind of samples collected from uncontaminated area. The results of the investigation show that ferrochrome smelter is a source of environmental pollution with contamination factors of Cr(VI) ranging between 10 and 50.

  11. Environmental DNA from seawater samples correlate with trawl catches of Subarctic, deepwater fishes

    DEFF Research Database (Denmark)

    Thomsen, Philip Francis; Møller, Peter Rask; Sigsgaard, Eva Egelyng

    2016-01-01

    such as bottom trawling, and on official reporting of global catches, which can be unreliable. Thus, there is need for alternative and non-invasive techniques for qualitative and quantitative oceanic fish surveys. Here we report environmental DNA (eDNA) metabarcoding of seawater samples from continental slope...... depths in Southwest Greenland. We collected seawater samples at depths of 188-918 m and compared seawater eDNA to catch data from trawling. We used Illumina sequencing of PCR products to demonstrate that eDNA reads show equivalence to fishing catch data obtained from trawling. Twenty-six families were...... found with both trawling and eDNA, while three families were found only with eDNA and two families were found only with trawling. Key commercial fish species for Greenland were the most abundant species in both eDNA reads and biomass catch, and interpolation of eDNA abundances between sampling sites...

  12. Compendium of Environmental Sustainability Indicator Collections: Rio to Johannesburg Dashboard of Sustainable Indicators

    Data.gov (United States)

    National Aeronautics and Space Administration — The Rio to Johannesburg Dashboard of Sustainable Development Indicators portion of the Compendium of Environmental Sustainability Indicator Collections contains 35...

  13. Storage Effects on Sample Integrity of Environmental Surface Sampling Specimens with Bacillus anthracis Spores.

    Science.gov (United States)

    Perry, K Allison; O'Connell, Heather A; Rose, Laura J; Noble-Wang, Judith A; Arduino, Matthew J

    The effect of packaging, shipping temperatures and storage times on recovery of Bacillus anthracis . Sterne spores from swabs was investigated. Macrofoam swabs were pre-moistened, inoculated with Bacillus anthracis spores, and packaged in primary containment or secondary containment before storage at -15°C, 5°C, 21°C, or 35°C for 0-7 days. Swabs were processed according to validated Centers for Disease Control/Laboratory Response Network culture protocols, and the percent recovery relative to a reference sample (T 0 ) was determined for each variable. No differences were observed in recovery between swabs held at -15° and 5°C, (p ≥ 0.23). These two temperatures provided significantly better recovery than swabs held at 21°C or 35°C (all 7 days pooled, p ≤ 0.04). The percent recovery at 5°C was not significantly different if processed on days 1, 2 or 4, but was significantly lower on day 7 (day 2 vs. 7, 5°C, 10 2 , p=0.03). Secondary containment provided significantly better percent recovery than primary containment, regardless of storage time (5°C data, p ≤ 0.008). The integrity of environmental swab samples containing Bacillus anthracis spores shipped in secondary containment was maintained when stored at -15°C or 5°C and processed within 4 days to yield the optimum percent recovery of spores.

  14. A whole-cell bioreporter assay for quantitative genotoxicity evaluation of environmental samples.

    Science.gov (United States)

    Jiang, Bo; Li, Guanghe; Xing, Yi; Zhang, Dayi; Jia, Jianli; Cui, Zhisong; Luan, Xiao; Tang, Hui

    2017-10-01

    Whole-cell bioreporters have emerged as promising tools for genotoxicity evaluation, due to their rapidity, cost-effectiveness, sensitivity and selectivity. In this study, a method for detecting genotoxicity in environmental samples was developed using the bioluminescent whole-cell bioreporter Escherichia coli recA::luxCDABE. To further test its performance in a real world scenario, the E. coli bioreporter was applied in two cases: i) soil samples collected from chromium(VI) contaminated sites; ii) crude oil contaminated seawater collected after the Jiaozhou Bay oil spill which occurred in 2013. The chromium(VI) contaminated soils were pretreated by water extraction, and directly exposed to the bioreporter in two phases: aqueous soil extraction (water phase) and soil supernatant (solid phase). The results indicated that both extractable and soil particle fixed chromium(VI) were bioavailable to the bioreporter, and the solid-phase contact bioreporter assay provided a more precise evaluation of soil genotoxicity. For crude oil contaminated seawater, the response of the bioreporter clearly illustrated the spatial and time change in genotoxicity surrounding the spill site, suggesting that the crude oil degradation process decreased the genotoxic risk to ecosystem. In addition, the performance of the bioreporter was simulated by a modified cross-regulation gene expression model, which quantitatively described the DNA damage response of the E. coli bioreporter. Accordingly, the bioluminescent response of the bioreporter was calculated as the mitomycin C equivalent, enabling quantitative comparison of genotoxicities between different environmental samples. This bioreporter assay provides a rapid and sensitive screening tool for direct genotoxicity assessment of environmental samples. Copyright © 2017. Published by Elsevier Ltd.

  15. 77 FR 38323 - Proposed Extension of Existing Information Collection; Respirable Coal Mine Dust Sampling

    Science.gov (United States)

    2012-06-27

    ... Information Collection; Respirable Coal Mine Dust Sampling AGENCY: Mine Safety and Health Administration... Sampling'' to more accurately reflect the type of information that is collected. Chronic exposure to... dust levels since 1970 and, consequently, the prevalence rate of black lung among coal miners, severe...

  16. New Lipids From Cultured Archaea and Environmental Samples

    Science.gov (United States)

    Summons, R. E.; Meyer-Dombard, D. R.; Bradley, A. S.; Hebting, Y.; Jahnke, L. L.; Embaye, T.; Orphan, V. J.

    2006-12-01

    The intact polar lipids of Archaea comprise cores with isoprenoid hydrocarbon chains with 20, 25 or 40 carbon atoms linked through ether bonds to glycerol. These cores can take the form of diethers or membrane- spanning tetraethers. Together with their wide array of polar head groups, these compounds are structurally diverse and potentially very useful as taxonomic markers for making assessments of microbial diversity independently of genomic approaches. Furthermore, the recalcitrant hydrocarbon chains of these lipids are the only really effective means to identify the presence of Archaea in ancient sedimentary environments. The advent of new LC-MS methods has enabled ready identification and quantification of intact polar lipids in cultures and environmental samples based on comparisons with appropriate standard compounds [1, 2]. However, these LC-MS analyses of intact lipids have also revealed the presence of additional compounds and it is likely that many of these represent chemical structures that are new to science. Elucidating these structures is a major analytical challenge because, generally, only minute amounts of material available for chemical characterization. In order to study these potentially new structures, one layer of information can be obtained by chemical degradation to remove and identify the polar head groups [2]. Cleavage of the ether bonds releases the hydrocarbon chains for their further characterization. One class of core lipids, the 3-hydroxyarchaeols, escaped detection for many years because strong acid treatments in the analysis protocols had destroyed hydroxyl-containing isoprenoid chains. We have now re-examined the lipids of a thermophilic methanogen, M. thermolithotrophicus, using mild procedures and avoiding strong acids. As well as the known compounds archaeol, sn-2-hydroxyarchaeol and sn-3-hydroxyarchaeol, we encountered dihydroxyarchaeol. Moreover, the hydroxylated archaeols were found to exist as a very complex mixture of

  17. Genomic Sequencing of Single Microbial Cells from Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Ishoey, Thomas; Woyke, Tanja; Stepanauskas, Ramunas; Novotny, Mark; Lasken, Roger S.

    2008-02-01

    Recently developed techniques allow genomic DNA sequencing from single microbial cells [Lasken RS: Single-cell genomic sequencing using multiple displacement amplification, Curr Opin Microbiol 2007, 10:510-516]. Here, we focus on research strategies for putting these methods into practice in the laboratory setting. An immediate consequence of single-cell sequencing is that it provides an alternative to culturing organisms as a prerequisite for genomic sequencing. The microgram amounts of DNA required as template are amplified from a single bacterium by a method called multiple displacement amplification (MDA) avoiding the need to grow cells. The ability to sequence DNA from individual cells will likely have an immense impact on microbiology considering the vast numbers of novel organisms, which have been inaccessible unless culture-independent methods could be used. However, special approaches have been necessary to work with amplified DNA. MDA may not recover the entire genome from the single copy present in most bacteria. Also, some sequence rearrangements can occur during the DNA amplification reaction. Over the past two years many research groups have begun to use MDA, and some practical approaches to single-cell sequencing have been developed. We review the consensus that is emerging on optimum methods, reliability of amplified template, and the proper interpretation of 'composite' genomes which result from the necessity of combining data from several single-cell MDA reactions in order to complete the assembly. Preferred laboratory methods are considered on the basis of experience at several large sequencing centers where >70% of genomes are now often recovered from single cells. Methods are reviewed for preparation of bacterial fractions from environmental samples, single-cell isolation, DNA amplification by MDA, and DNA sequencing.

  18. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  19. Veterinary antibiotic resistance, residues, and ecological risks in environmental samples obtained from poultry farms, Egypt.

    Science.gov (United States)

    Dahshan, Hesham; Abd-Elall, Amr Mohamed Mohamed; Megahed, Ayman Mohamed; Abd-El-Kader, Mahdy A; Nabawy, Ehab Elsayed

    2015-02-01

    In Egypt, poultry production constitutes one of the main sources of pollution with veterinary antibiotics (VAs) into the environment. About 80 % of meat production in Egypt is of poultry origin, and the potential environmental risks associated with the use of VAs in these farms have not yet been properly evaluated. Thus, the main purpose of this research was to evaluate the prevalence of antibiotic-resistant enteric key bacteria and the incidence of residual antibiotics in poultry farm environmental samples and to determine whether fertilizing soils with poultry litter from farms potentially brings ecological risks. From December 2011 to September 2012, a total of 225 litter, bird dropping, and water samples were collected from 75 randomly selected boiler poultry farms. A high prevalence of Escherichia coli (n = 179; 79.5 %) in contrast to the low prevalence of Salmonella spp. (n = 7; 3.1 %) was detected. Amongst E. coli isolates, serotypes O142:K86, O125:K70, O91:K, and O119:K69 were the most common. Meanwhile, Salmonella enterica serotypes emek and enteritidis were recovered. The antibiograms using the disc diffusion method revealed significantly more common resistant and multi-resistant isolates in broiler poultry farms. Residues of tetracycline and ciprofloxacin were detected at 2.125 and 1.401 mg kg(-1) mean levels, respectively, in environmental samples contaminated with E. coli-resistant strains by HPLC. The risk evaluations highlighted that tetracycline residues in poultry litter significantly display environmental risks with a hazard quotient value above 1 (1.64). Our study implies that ineffective implementation of veterinary laws which guide and guard against incorrect VA usage may potentially bring health and environmental risks.

  20. Theorical and practical bases for blood sample collection from the heel of newborns for neonatal screening

    Directory of Open Access Journals (Sweden)

    Marcela Vela-Amieva

    2014-07-01

    collected in a special filter paper (Guthrie’s card. Despite its apparent simplicity, NBS laboratories commonly receive a large number of samples collected incorrectly and technically unsuitable for perfor4ming biochemical determinations. The aim of the present paper is to offer recommendations based on scientific evidence, for the properly blood collection on filter paper for NBS programs.

  1. Trace Elements Analysis of Archeological Brick Samples Collected from Different Historical Placs in Rajshahi Division

    International Nuclear Information System (INIS)

    Begum, Bilkis A.; Biswas, Shapan K.; Matin, Mohammed A.; Hoque, Mohammed M.; Hopke, Philip K.

    2007-01-01

    Twenty-nine brick samples were collected from different temples and palaces, namely Paharpur, Kumarpur, Gaurbari, Puthia and Natore in Rajshahi Division in Bangladesh. The samples were analyzed by X-ray Fluorescence (XRF) method. The elemental data sets have been analyzed in order to find out the general characteristics and any significant differences among the collected samples and identify the origin of these brick samples. Most of the crustal elements have enrichment factor (EF) values close to unity. Only Cu and Pb have high values that may come from painting as these have been collected from temples and palaces.(author)

  2. ASPECT (Airborne Spectral Photometric Environmental Collection Technology) Fact Sheet

    Science.gov (United States)

    This multi-sensor screening tool provides infrared and photographic images with geospatial, chemical, and radiological data within minutes to support emergency responses, home-land security missions, environmental surveys, and climate monitoring missions.

  3. Dehalococcoides as a Potential Biomarker Evidence for Uncharacterized Organohalides in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Qihong Lu

    2017-09-01

    Full Text Available The massive production and improper disposal of organohalides resulted in worldwide contamination in soil and water. However, their environmental survey based on chromatographic methods was hindered by challenges in testing the extremely wide variety of organohalides. Dehalococcoides as obligate organohalide-respiring bacteria exclusively use organohalides as electron acceptors to support their growth, of which the presence could be coupled with organohalides and, therefore, could be employed as a biomarker of the organohalide pollution. In this study, Dehalococcoides was screened in various samples of bioreactors and subsurface environments, showing the wide distribution of Dehalococcoides in sludge and sediment. Further laboratory cultivation confirmed the dechlorination activities of those Dehalococcoides. Among those samples, Dehalococcoides accounting for 1.8% of the total microbial community was found in an anaerobic granular sludge sample collected from a full-scale bioreactor treating petroleum wastewater. Experimental evidence suggested that the influent wastewater in the bioreactor contained bromomethane which support the growth of Dehalococcoides. This study demonstrated that Dehalococcoides could be employed as a promising biomarker to test the present of organohalides in wastestreams or other environmental samples.

  4. Cesium-137 and natural radionuclides in soils from southern Brazil and soils and others environmental samples from Antarctic

    International Nuclear Information System (INIS)

    Schuch, L.A.

    1993-04-01

    This work presents a study of environmental artificial and natural radioactivity levels in soil samples from the Southern Brazil and in soils and other environmental samples form Antarctica. Artificial radioactivity was determined by measuring Cs-137 which is a 30.1 year half-life man-made radionuclide produced in the past by atmospheric tests of nuclear weapons. Natural radioactivity was determined by measuring some radionuclides belonging to Th-232 and U-238 natural radioactive families, and of K-40 concentrations. Several types of soils from Southern Brazil; and soil samples, marine sediments, lichens, mosses and algae collected at King George and other nearby islands (South Shetland Archipelago, Antarctica) were analyzed. A gamma-ray spectrometer was used to measure radioactivity levels of the collected samples and its overall characteristics are analyzed in this work. (author)

  5. 78 FR 79009 - Proposed Information Collection; Radiation Sampling and Exposure Records (Pertains to Underground...

    Science.gov (United States)

    2013-12-27

    ... soliciting comments concerning the proposed information collection for updating Radiation Sampling and... exposed with no adverse effects have been established and are expressed as working levels (WL). The... mandatory samplings. Records must include the sample date, location, and results, and must be retained at...

  6. 78 FR 50079 - Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed...

    Science.gov (United States)

    2013-08-16

    ... DEPARTMENT OF THE INTERIOR Bureau of Safety and Environmental Enforcement [Docket ID BSEE-2013-0005; OMB Control Number 1014-0017: 134E1700D2 EEEE500000 ET1SF0000.DAQ000] Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed Collection; Comment Request...

  7. Distribution of {sup 90}Sr activities in the environmental radiation samples of Jeju Island, Korea

    Energy Technology Data Exchange (ETDEWEB)

    Han, Chung Hun; Park, Youn Hyun; Lee, Young Gyu; Park, Jae Woo [Jeju National University, Jeju (Korea, Republic of)

    2016-12-15

    This work was to get information about {sup 90}Sr contamination of the environment by using soil and moss from selected areas in Jeju Island, Korea. The activities of {sup 90}Sr in soil and moss samples were investigated at nine locations of Jeju island, Korea. The soil samples have been collected at 4 sites of Jeju island during June to August of 2013, analyzed for vertical distribution of {sup 90}Sr activities. The moss samples have been collected at 5 sites of Jeju island during November of 2011 to June of 2012, and analyzed for radioactive {sup 90}Sr. The {sup 90}Sr vertical concentrations in the investigated soil samples were 2.77 to 18.24 Bq·kg{sup -1} in eastern part, 1.69 to 18.27 Bq·kg{sup -1} in northern part, 3.76 to 13.46 Bq·kg{sup -1} in the western part and 1.09 to 8.70 Bq·kg{sup -1} in the southern part of the Mt. Halla in Jeju island, respectively. Activities of {sup 90}Sr show the highest value at the surface soil and decrease with depth. The activity concentration measured was in the range of 79.6 to 363 Bq·kg{sup -1} -dry moss. This material is expected to be basis reference for survey of environmental radioactivity in Jeju Island.

  8. Metagenomic covariation along densely sampled environmental gradients in the Red Sea

    Science.gov (United States)

    Thompson, Luke R; Williams, Gareth J; Haroon, Mohamed F; Shibl, Ahmed; Larsen, Peter; Shorenstein, Joshua; Knight, Rob; Stingl, Ulrich

    2017-01-01

    Oceanic microbial diversity covaries with physicochemical parameters. Temperature, for example, explains approximately half of global variation in surface taxonomic abundance. It is unknown, however, whether covariation patterns hold over narrower parameter gradients and spatial scales, and extending to mesopelagic depths. We collected and sequenced 45 epipelagic and mesopelagic microbial metagenomes on a meridional transect through the eastern Red Sea. We asked which environmental parameters explain the most variation in relative abundances of taxonomic groups, gene ortholog groups, and pathways—at a spatial scale of water mass with different physicochemical properties. Temperature explained the most variation in each metric, followed by nitrate, chlorophyll, phosphate, and salinity. That nitrate explained more variation than phosphate suggested nitrogen limitation, consistent with low surface N:P ratios. Covariation of gene ortholog groups with environmental parameters revealed patterns of functional adaptation to the challenging Red Sea environment: high irradiance, temperature, salinity, and low nutrients. Nutrient-acquisition gene ortholog groups were anti-correlated with concentrations of their respective nutrient species, recapturing trends previously observed across much larger distances and environmental gradients. This dataset of metagenomic covariation along densely sampled environmental gradients includes online data exploration supplements, serving as a community resource for marine microbial ecology. PMID:27420030

  9. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for

  10. Historical review of long-term soil sampling for environmental surveillance at the Hanford Site and vicinity

    Energy Technology Data Exchange (ETDEWEB)

    Price, K.R.; Rickard, W.H.

    1997-08-01

    Soil samples have been collected routinely from the environs of the Hanford Site and analyzed since 1971. Correct interpretation of results depends on samples being collected from the same locations, the locations remaining relatively undisturbed, and collection and analytical procedures remaining the same or being equivalent. Historical files, documents, and annual environmental reports were reviewed to evaluate these factors. It was determined that 20 soil sampling locations, 11 onsite and 9 offsite, were established between 1971 and 1977 and represent long-term sampling locations. Sample collection and analytical procedures have remained essentially the same since 1971. The physical ecological attributes of each long-term soil sampling location were evaluated. During the review of historical records, a few results for 1970, 1971, and 1972 were noted as previously unreported in annual or special reports. These results are included in Appendix A. To complete the record, results previously reported in annual environmental reports are given in Appendix B. Global Positioning System (GPS) reading for 20 long-term soil sampling locations are provided in Appendix C.

  11. Historical review of long-term soil sampling for environmental surveillance at the Hanford Site and vicinity

    International Nuclear Information System (INIS)

    Price, K.R.; Rickard, W.H.

    1997-08-01

    Soil samples have been collected routinely from the environs of the Hanford Site and analyzed since 1971. Correct interpretation of results depends on samples being collected from the same locations, the locations remaining relatively undisturbed, and collection and analytical procedures remaining the same or being equivalent. Historical files, documents, and annual environmental reports were reviewed to evaluate these factors. It was determined that 20 soil sampling locations, 11 onsite and 9 offsite, were established between 1971 and 1977 and represent long-term sampling locations. Sample collection and analytical procedures have remained essentially the same since 1971. The physical ecological attributes of each long-term soil sampling location were evaluated. During the review of historical records, a few results for 1970, 1971, and 1972 were noted as previously unreported in annual or special reports. These results are included in Appendix A. To complete the record, results previously reported in annual environmental reports are given in Appendix B. Global Positioning System (GPS) reading for 20 long-term soil sampling locations are provided in Appendix C

  12. Assembly for collecting samples for purposes of identification or analysis and method of use

    Science.gov (United States)

    Thompson, Cyril V [Knoxville, TN; Smith, Rob R [Knoxville, TN

    2010-02-02

    An assembly and an associated method for collecting a sample of material desired to be characterized with diagnostic equipment includes or utilizes an elongated member having a proximal end with which the assembly is manipulated by a user and a distal end. In addition, a collection tip which is capable of being placed into contact with the material to be characterized is supported upon the distal end. The collection tip includes a body of chemically-inert porous material for binding a sample of material when the tip is placed into contact with the material and thereby holds the sample of material for subsequent introduction to the diagnostic equipment.

  13. [Establishment and Management of Multicentral Collection Bio-sample Banks of Malignant Tumors from Digestive System].

    Science.gov (United States)

    Shen, Si; Shen, Junwei; Zhu, Liang; Wu, Chaoqun; Li, Dongliang; Yu, Hongyu; Qiu, Yuanyuan; Zhou, Yi

    2015-11-01

    To establish and manage of multicentral collection bio-sample banks of malignant tumors from digestive system, the paper designed a multicentral management system, established the standard operation procedures (SOPs) and leaded ten hospitals nationwide to collect tumor samples. The biobank has been established for half a year, and has collected 695 samples from patients with digestive system malignant tumor. The clinical data is full and complete, labeled in a unified way and classified to be managed. The clinical and molecular biology researches were based on the biobank, and obtained achievements. The biobank provides a research platform for malignant tumor of digestive system from different regions and of different types.

  14. Long-term survival of Cryptococcus neoformans and Cryptococcus gattii in stored environmental samples from Colombia.

    Science.gov (United States)

    Escandón, Patricia; Castañeda, Elizabeth

    2015-01-01

    Both Cryptococcus neoformans and Cryptococcus gattii have been isolated from a variety of environmental sources in Colombia. To determine the viability of C. neoformans/C. gattii isolates in stored soil samples, filtrates and bird droppings from which these yeasts were previously recovered. A total of 964 samples collected between 2003 and 2009, and kept at room temperature were processed. From them, 653 samples were from trees decaying wood, 274 from soil filtrates and 37 from bird droppings. When C. neoformans or C. gattii were recovered, the molecular type of each isolate was established by PCR fingerprinting using the single primer (GTG)5. Among the processed samples, 161 isolates were recovered. From those, 81 (50.3%) corresponded to C. gattii recovered from decaying wood of Eucalyptus spp., Corymbia ficifolia, Terminalia catappa and Ficus spp. trees, and 80 (49.7%) corresponded to C. neoformans recovered from Ficus spp. and eucalyptus trees, as well as from bird droppings. The most prevalent molecular type among the C. gattii and C. neoformans isolates was VGII and VNI, respectively. The re-isolation of C. neoformans/C. gattii from 10-year stored samples suggests that these yeasts are able to keep viable in naturally colonized samples. Copyright © 2013 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.

  15. Automated high-volume aerosol sampling station for environmental radiation monitoring

    International Nuclear Information System (INIS)

    Toivonen, H.; Honkamaa, T.; Ilander, T.; Leppaenen, A.; Nikkinen, M.; Poellaenen, R.; Ylaetalo, S.

    1998-07-01

    An automated high-volume aerosol sampling station, known as CINDERELLA.STUK, for environmental radiation monitoring has been developed by the Radiation and Nuclear Safety Authority (STUK), Finland. The sample is collected on a glass fibre filter (attached into a cassette), the airflow through the filter is 800 m 3 /h at maximum. During the sampling, the filter is continuously monitored with Na(I) scintillation detectors. After the sampling, the large filter is automatically cut into 15 pieces that form a small sample and after ageing, the pile of filter pieces is moved onto an HPGe detector. These actions are performed automatically by a robot. The system is operated at a duty cycle of 1 d sampling, 1 d decay and 1 d counting. Minimum detectable concentrations of radionuclides in air are typically 1Ae10 x 10 -6 Bq/m 3 . The station is equipped with various sensors to reveal unauthorized admittance. These sensors can be monitored remotely in real time via Internet or telephone lines. The processes and operation of the station are monitored and partly controlled by computer. The present approach fulfils the requirements of CTBTO for aerosol monitoring. The concept suits well for nuclear material safeguards, too

  16. Onondaga Lake: A Forsaken Superfund Site, or a Sampling Playground for Environmental Geochemistry Classes?

    Science.gov (United States)

    Karmosky, C. C.; Harpp, K. S.

    2004-05-01

    Onondaga Lake, in Syracuse, NY, is described by the EPA as one of the most polluted lakes in the US. High levels of heavy metal and semi-volatile organic contamination provide an excellent case study that serves as the cornerstone for an environmental geochemistry course at Colgate University. Our course is designed to teach students basic environmental analysis skills including experimental design, sample preparation, analytical instrumentation operation, data processing and statistical analysis, and preparation of a collaborative scientific paper. Participating students generally have some background in environmental geology, but rarely more than one semester of chemistry. The Onondaga Lake project is the focus of the course for approximately half the semester. At the outset of the project, students are presented with a driving question that is answered through a series of guided field and lab investigations, such as an assessment of the environmental consequences of a proposed marina along the lakefront. The students' first task is to delve into the lake's environmental history, including identification of contaminants, location of point and non-point pollution sources, and clean-up efforts. Students then participate in 2 field trips to the site. First, students learn the geography of the lake system, collect sediment and water samples, and observe mitigation efforts at the wastewater treatment plant. The second trip is 2-3 weeks later, after students have assessed further sampling needs. Identification and quantification of organic compounds are accomplished by GC-MS, and heavy metal contents are determined by ICP-MS. Students compile their results, perform statistical analyses, and collaboratively draw their conclusions regarding the impact of the proposed project. The final product is a single report written by the entire class, an exercise in organization, cooperation, and planning that is usually the most challenging, but ultimately the most rewarding

  17. Environmental DNA from seawater samples correlate with trawl catches of Subarctic, deepwater fishes

    DEFF Research Database (Denmark)

    Thomsen, Philip Francis; Møller, Peter Rask; Sigsgaard, Eva Egelyng

    2016-01-01

    depths in Southwest Greenland. We collected seawater samples at depths of 188-918 m and compared seawater eDNA to catch data from trawling. We used Illumina sequencing of PCR products to demonstrate that eDNA reads show equivalence to fishing catch data obtained from trawling. Twenty-six families were......Remote polar and deepwater fish faunas are under pressure from ongoing climate change and increasing fishing effort. However, these fish communities are difficult to monitor for logistic and financial reasons. Currently, monitoring of marine fishes largely relies on invasive techniques...... such as bottom trawling, and on official reporting of global catches, which can be unreliable. Thus, there is need for alternative and non-invasive techniques for qualitative and quantitative oceanic fish surveys. Here we report environmental DNA (eDNA) metabarcoding of seawater samples from continental slope...

  18. IMPROVEMENT OF METHODS FOR HYDROBIOLOGICAL RESEARCH AND MODIFICATION OF STANDARD TOOLS FOR SAMPLE COLLECTION

    Directory of Open Access Journals (Sweden)

    M. M. Aligadjiev

    2015-01-01

    Full Text Available Aim. The paper discusses the improvement of methods of hydrobiological studies by modifying tools for plankton and benthic samples collecting. Methods. In order to improve the standard methods of hydro-biological research, we have developed tools for sampling zooplankton and benthic environment of the Caspian Sea. Results. Long-term practice of selecting hydrobiological samples in the Caspian Sea shows that it is required to complete the modernization of the sampling tools used to collect hydrobiological material. With the introduction of Azov and Black Sea invasive comb jelly named Mnemiopsis leidyi A. Agassiz to the Caspian Sea there is a need to collect plankton samples without disturbing its integrity. Tools for collecting benthic fauna do not always give a complete picture of the state of benthic ecosystems because of the lack of visual site selection for sampling. Moreover, while sampling by dredge there is a probable loss of the samples, especially in areas with difficult terrain. Conclusion. We propose to modify a small model of Upstein net (applied in shallow water to collect zooplankton samples with an upper inverted cone that will significantly improve the catchability of the net in theCaspian Sea. Bottom sampler can be improved by installing a video camera for visual inspection of the bottom topography, and use sensors to determine tilt of the dredge and the position of the valves of the bucket. 

  19. Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives.

    Science.gov (United States)

    Verkouteren, Jennifer R; Lawrence, Jeffrey A; Staymates, Matthew E; Sisco, Edward

    2017-04-10

    One of the limiting steps to detecting traces of explosives at screening venues is effective collection of the sample. Wipe-sampling is the most common procedure for collecting traces of explosives, and standardized measurements of collection efficiency are needed to evaluate and optimize sampling protocols. The approach described here is designed to provide this measurement infrastructure, and controls most of the factors known to be relevant to wipe-sampling. Three critical factors (the applied force, travel distance, and travel speed) are controlled using an automated device. Test surfaces are chosen based on similarity to the screening environment, and the wipes can be made from any material considered for use in wipe-sampling. Particle samples of the explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) are applied in a fixed location on the surface using a dry-transfer technique. The particle samples, recently developed to simulate residues made after handling explosives, are produced by inkjet printing of RDX solutions onto polytetrafluoroethylene (PTFE) substrates. Collection efficiency is measured by extracting collected explosive from the wipe, and then related to critical sampling factors and the selection of wipe material and test surface. These measurements are meant to guide the development of sampling protocols at screening venues, where speed and throughput are primary considerations.

  20. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    Energy Technology Data Exchange (ETDEWEB)

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear

  1. Assessment of the Capability of the NGDS Prototype to Replace the JBAIDS for Environmental Sample Analysis

    Science.gov (United States)

    2016-11-01

    Diagnostic System (JBAIDS) for environmental sample analysis. JUPITR ATD and USAF members analyzed environmental samples using the FilmArray...requires 60+ min for sample preparation, whereas the FilmArray system (right) uses highly multiplexed assay pouches that require ᝺ min for sample...supported the evaluation of the BDCoE by analyzing spiked DFU samples using the Joint Biological Agent Identification and Diagnostic System (JBAIDS) and the

  2. Development of analytical methods for the separation of plutonium, americium, curium and neptunium from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Salminen, S.

    2009-07-01

    In this work, separation methods have been developed for the analysis of anthropogenic transuranium elements plutonium, americium, curium and neptunium from environmental samples contaminated by global nuclear weapons testing and the Chernobyl accident. The analytical methods utilized in this study are based on extraction chromatography. Highly varying atmospheric plutonium isotope concentrations and activity ratios were found at both Kurchatov (Kazakhstan), near the former Semipalatinsk test site, and Sodankylae (Finland). The origin of plutonium is almost impossible to identify at Kurchatov, since hundreds of nuclear tests were performed at the Semipalatinsk test site. In Sodankylae, plutonium in the surface air originated from nuclear weapons testing, conducted mostly by USSR and USA before the sampling year 1963. The variation in americium, curium and neptunium concentrations was great as well in peat samples collected in southern and central Finland in 1986 immediately after the Chernobyl accident. The main source of transuranium contamination in peats was from global nuclear test fallout, although there are wide regional differences in the fraction of Chernobyl-originated activity (of the total activity) for americium, curium and neptunium. The separation methods developed in this study yielded good chemical recovery for the elements investigated and adequately pure fractions for radiometric activity determination. The extraction chromatographic methods were faster compared to older methods based on ion exchange chromatography. In addition, extraction chromatography is a more environmentally friendly separation method than ion exchange, because less acidic waste solutions are produced during the analytical procedures. (orig.)

  3. The U.S. Geological Survey Geologic Collections Management System (GCMS)—A master catalog and collections management plan for U.S. Geological Survey geologic samples and sample collections

    Science.gov (United States)

    ,

    2015-01-01

    The U.S. Geological Survey (USGS) is widely recognized in the earth science community as possessing extensive collections of earth materials collected by research personnel over the course of its history. In 2006, a Geologic Collections Inventory was conducted within the USGS Geology Discipline to determine the extent and nature of its sample collections, and in 2008, a working group was convened by the USGS National Geologic and Geophysical Data Preservation Program to examine ways in which these collections could be coordinated, cataloged, and made available to researchers both inside and outside the USGS. The charge to this working group was to evaluate the proposition of creating a Geologic Collections Management System (GCMS), a centralized database that would (1) identify all existing USGS geologic collections, regardless of size, (2) create a virtual link among the collections, and (3) provide a way for scientists and other researchers to obtain access to the samples and data in which they are interested. Additionally, the group was instructed to develop criteria for evaluating current collections and to establish an operating plan and set of standard practices for handling, identifying, and managing future sample collections. Policies and procedures promoted by the GCMS would be based on extant best practices established by the National Science Foundation and the Smithsonian Institution. The resulting report—USGS Circular 1410, “The U.S. Geological Survey Geologic Collections Management System (GCMS): A Master Catalog and Collections Management Plan for U.S. Geological Survey Geologic Samples and Sample Collections”—has been developed for sample repositories to be a guide to establishing common practices in the collection, retention, and disposal of geologic research materials throughout the USGS.

  4. Variability and reliability of POP concentrations in multiple breast milk samples collected from the same mothers.

    Science.gov (United States)

    Kakimoto, Risa; Ichiba, Masayoshi; Matsumoto, Akiko; Nakai, Kunihiko; Tatsuta, Nozomi; Iwai-Shimada, Miyuki; Ishiyama, Momoko; Ryuda, Noriko; Someya, Takashi; Tokumoto, Ieyasu; Ueno, Daisuke

    2018-01-13

    Risk assessment of infant using a realistic persistent organic pollutant (POP) exposure through breast milk is essential to devise future regulation of POPs. However, recent investigations have demonstrated that POP levels in breast milk collected from the same mother showed a wide range of variation daily and monthly. To estimate the appropriate sample size of breast milk from the same mother to obtain reliable POP concentrations, breast milk samples were collected from five mothers living in Japan from 2006 to 2012. Milk samples from each mother were collected 3 to 6 times a day through 3 to 7 days consecutively. Food samples as the duplicated method were collected from two mothers during the period of breast milk sample collection. Those were employed for POP (PCBs, DDTs, chlordanes, and HCB) analysis. PCB concentrations detected in breast milk samples showed a wide range of variation which was maximum 63 and 60% of relative standard deviation (RSD) in lipid and wet weight basis, respectively. The time course trend of those variations among the mothers did not show any typical pattern. A larger amount of PCB intake through food seemed to affect 10 h after those concentrations in breast milk in lipid weight basis. Intraclass correlation coefficient (ICC) analyses indicated that the appropriate sample size for good reproducibility of POP concentrations in breast milk required at least two samples for lipid and wet weight basis.

  5. BAYESIAN ENTROPY FOR SPATIAL SAMPLING DESIGN OF ENVIRONMENTAL DATA

    Science.gov (United States)

    Particulate Matter (PM) has been linked to widespread public health effects, including a range of serious respiratory and cardiovascular problems, and to reduced visibility in may parts of the United States, see the Environmental Protection Agency (EPA) report (2004) and relevant...

  6. a study of predictors of environmental behaviour using us samples

    African Journals Online (AJOL)

    ressed in curriculum development and instructional practice. The ultimate goal of ... lem solving behaviour may not be given due consid- eration because ... ion strategies. Respondents were assessed regard- ing their perceived ability to influence the sol- ution of environmental problems/issues either as an individual or ...

  7. Analysis of environmental samples by roentgen fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Hroncova, E.; Ladomersky, J.

    2004-01-01

    We can use it to analyse nearly all elements of solid and liquid samples. The possibility of analysing solid samples in compact shape, in powder or either under shape of fine layers shortens appreciably the total time of analysis, that is in addition to its no destructiveness, the main reason of as a XRF favourite method. (authors)

  8. Normalisation of spot urine samples to 24-h collection for assessment of exposure to uranium

    International Nuclear Information System (INIS)

    Marco, R.; Katorza, E.; Gonen, R.; German, U.; Tshuva, A.; Pelled, O.; Paz-tal, O.; Adout, A.; Karpas, Z.

    2008-01-01

    For dose assessment of workers at Nuclear Research Center Negev exposed to natural uranium, spot urine samples are analysed and the results are normalised to 24-h urine excretion based on 'standard' man urine volume of 1.6 l d -1 . In the present work, the urine volume, uranium level and creatinine concentration were determined in two or three 24-h urine collections from 133 male workers (319 samples) and 33 female workers (88 samples). Three volunteers provided urine spot samples from each voiding during a 24-h period and a good correlation was found between the relative level of creatinine and uranium in spot samples collected from the same individual. The results show that normalisation of uranium concentration to creatinine in a spot sample represents the 24-h content of uranium better than normalisation to the standard volume and may be used to reduce the uncertainty of dose assessment based on spot samples. (authors)

  9. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  10. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    Science.gov (United States)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  11. Field sampling of soil pore water to evaluate trace element mobility and associated environmental risk

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Jimenez, Eduardo, E-mail: eduardo.moreno@uam.es [Departamento de Quimica Agricola, Universidad Autonoma de Madrid, 28049 Madrid (Spain); Beesley, Luke [James Hutton Institute, Craigiebuckler, Aberdeen AB15 8QH (United Kingdom); Lepp, Nicholas W. [35, Victoria Road, Formby, Liverpool L37 7DH (United Kingdom); Dickinson, Nicholas M. [Department of Ecology, Lincoln University, Lincoln 7647, PO Box 84 (New Zealand); Hartley, William [School of Computing, Science and Engineering, University of Salford, Cockcroft Building, Salford, M5 4WT (United Kingdom); Clemente, Rafael [Dep. of Soil and Water Conservation and Organic Waste Management, CEBAS-CSIC, Campus Universitario de Espinardo, PO Box 164, 30100 Espinardo, Murcia (Spain)

    2011-10-15

    Monitoring soil pollution is a key aspect in sustainable management of contaminated land but there is often debate over what should be monitored to assess ecological risk. Soil pore water, containing the most labile pollutant fraction in soils, can be easily collected in situ offering a routine way to monitor this risk. We present a compilation of data on concentration of trace elements (As, Cd, Cu, Pb, and Zn) in soil pore water collected in field conditions from a range of polluted and non-polluted soils in Spain and the UK during single and repeated monitoring, and propose a simple eco-toxicity test using this media. Sufficient pore water could be extracted for analysis both under semi-arid and temperate conditions, and eco-toxicity comparisons could be effectively made between polluted and non-polluted soils. We propose that in-situ pore water extraction could enhance the realism of risk assessment at some contaminated sites. - Highlights: > In situ pore water sampling successfully evaluates trace elements mobility in soils. > Field sampling proved robust for different soils, sites and climatic regimes. > Measurements may be directly related to ecotoxicological assays. > Both short and long-term monitoring of polluted lands may be achieved. > This method complements other widely used assays for environmental risk assessment. - In situ pore water sampling from a wide variety of soils proves to be a beneficial application to monitor the stability of pollutants in soils and subsequent risk through mobility.

  12. Sampling procedure, receipt and conservation of water samples to determine environmental radioactivity

    International Nuclear Information System (INIS)

    Herranz, M.; Navarro, E.; Payeras, J.

    2009-01-01

    The present document informs about essential goals, processes and contents that the subgroups Sampling and Samples Preparation and Conservation believe they should be part of the procedure to obtain a correct sampling, receipt, conservation and preparation of samples of continental, marine and waste water before qualifying its radioactive content.

  13. Determination of uranium in industrial and environmental samples. Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    El-Sweify, F H; Shehata, M K; Metwally, E M; El-Shazly, E A.A.; El-Naggar, H A [Nuclear Chemistry Department, Hot Laborities Center, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    The phosphate ores used at `Abu zaabal fertilizer and chemical company` for the production of some chemicals and fertilizers contain detectable amounts of uranium. In this study, the content of uranium in samples of different products of fertilizers, gypsum, and phosphate ore were determined using NAA, and gamma ray spectroscopy of the irradiated samples. Another method based on measuring the natural radioactivity of {sup 238} U series for non-irradiated samples using gamma-ray spectroscopy was also used for determine uranium content in the samples. In the NAA method, the content of U(ppm) in the samples was been computed from the photopeak activity of the lines = 106.1, 228.2, and 277.5 KeV of {sup 239} Np induced in the irradiated samples, and the uranium standard simultaneously irradiated. the gamma-ray spectra, and the decay curves are given. In the second method the gamma-ray spectra of the natural radioactivity of the samples and uranium standard were measured. The gamma-transition of energies 295.1, 251.9 KeV for {sup 214} Pb; 609.3, 768.4, 1120.3, 1238.1 KeV for {sup 214} Bi were determined. The uranium {sup 23U} traces in drainage water was also determined spectrophotometrically using arsenazo-III after preconcentration of uranium from the pretreated drainage water in column packed with chelex-100 resin. The recovery was found to be 90 {+-} 5%. 11 figs., 3 tabs.

  14. The integrated performance evaluation program quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    EM's (DOE's Environmental Restoration and Waste Management) Integrated Performance Evaluation Program (IPEP) has the purpose of integrating information from existing PE programs with expanded QA activities to develop information about the quality of radiological, mixed waste, and hazardous environmental sample analyses provided by all laboratories supporting EM programs. The guidance addresses the goals of identifying specific PE sample programs and contacts, identifying specific requirements for participation in DOE's internal and external (regulatory) programs, identifying key issues relating to application and interpretation of PE materials for EM headquarters and field office managers, and providing technical guidance covering PE materials for site-specific activities. (PE) Performance Evaluation materials or samples are necessary for the quality assurance/control programs covering environmental data collection

  15. Simultaneous determination of plutonium and uranium in environmental samples

    International Nuclear Information System (INIS)

    Jiao Shufen

    1993-01-01

    Plutonium and uranium in a plant sample ash was simultaneously determined by using anion exchange resin columns, and concentrated hydrochloric acid and nitric acid. At the final stage of the determination of the nuclides, each of them was electrodeposited together with a little amount of molybdenum carrier onto a stainless steel plate and measured by α-ray spectrometer. The recoveries of uranium and plutonium from the plant samples determined by adding internal standard 236 Pu which was 100% and 63%, respectively

  16. Metagenomic covariation along densely sampled environmental gradients in the Red Sea

    KAUST Repository

    Thompson, Luke R

    2016-07-15

    Oceanic microbial diversity covaries with physicochemical parameters. Temperature, for example, explains approximately half of global variation in surface taxonomic abundance. It is unknown, however, whether covariation patterns hold over narrower parameter gradients and spatial scales, and extending to mesopelagic depths. We collected and sequenced 45 epipelagic and mesopelagic microbial metagenomes on a meridional transect through the eastern Red Sea. We asked which environmental parameters explain the most variation in relative abundances of taxonomic groups, gene ortholog groups, and pathways—at a spatial scale of <2000 km, along narrow but well-defined latitudinal and depth-dependent gradients. We also asked how microbes are adapted to gradients and extremes in irradiance, temperature, salinity, and nutrients, examining the responses of individual gene ortholog groups to these parameters. Functional and taxonomic metrics were equally well explained (75–79%) by environmental parameters. However, only functional and not taxonomic covariation patterns were conserved when comparing with an intruding water mass with different physicochemical properties. Temperature explained the most variation in each metric, followed by nitrate, chlorophyll, phosphate, and salinity. That nitrate explained more variation than phosphate suggested nitrogen limitation, consistent with low surface N:P ratios. Covariation of gene ortholog groups with environmental parameters revealed patterns of functional adaptation to the challenging Red Sea environment: high irradiance, temperature, salinity, and low nutrients. Nutrient-acquisition gene ortholog groups were anti-correlated with concentrations of their respective nutrient species, recapturing trends previously observed across much larger distances and environmental gradients. This dataset of metagenomic covariation along densely sampled environmental gradients includes online data exploration supplements, serving as a community

  17. Soil sample collection and analysis for the Fugitive Dust Characterization Study

    Science.gov (United States)

    Ashbaugh, Lowell L.; Carvacho, Omar F.; Brown, Michael S.; Chow, Judith C.; Watson, John G.; Magliano, Karen C.

    A unique set of soil samples was collected as part of the Fugitive Dust Characterization Study. The study was carried out to establish whether or not source profiles could be constructed using novel analytical methods that could distinguish soil dust sources from each other. The soil sources sampled included fields planted in cotton, almond, tomato, grape, and safflower, dairy and feedlot facilities, paved and unpaved roads (both urban and rural), an agricultural staging area, disturbed land with salt buildup, and construction areas where the topsoil had been removed. The samples were collected using a systematic procedure designed to reduce sampling bias, and were stored frozen to preserve possible organic signatures. For this paper the samples were characterized by particle size (percent sand, silt, and clay), dry silt content (used in EPA-recommended fugitive dust emission factors), carbon and nitrogen content, and potential to emit both PM 10 and PM 2.5. These are not the "novel analytical methods" referred to above; rather, it was the basic characterization of the samples to use in comparing analytical methods by other scientists contracted to the California Air Resources Board. The purpose of this paper is to document the methods used to collect the samples, the collection locations, the analysis of soil type and potential to emit PM 10, and the sample variability, both within field and between fields of the same crop type.

  18. An international study of the performance of sample collection from patients

    NARCIS (Netherlands)

    Dzik, WH; Murphy, MF; Andreu, G; Heddle, N; Hogman, C; Kekomaki, R; Murphy, S; Shimizu, M; Smit Sibinga, C.T.

    2003-01-01

    Background and Objectives Collection of a blood sample from the correct patient is the first step in the process of safe transfusion. The aim of this international collaborative study was to assess the frequency of mislabelled and miscollected samples drawn for blood grouping. Materials and Methods

  19. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of ... Conclusion: Acceptability of self-sampling for HPV testing was similarly excellent in both groups despite their difference in terms ... cancer is the leading cause of death caused by cancer in.

  20. Collecting Comet Samples by ER-2 Aircraft: Cosmic Dust Collection During the Draconid Meteor Shower in October 2012

    Science.gov (United States)

    Bastien, Ron; Burkett, P. J.; Rodriquez, M.; Frank, D.; Gonzalez, C.; Robinson, G.-A.; Zolensky, M.; Brown, P.; Campbell-Brown, M.; Broce, S.; hide

    2014-01-01

    Many tons of dust grains, including samples of asteroids and comets, fall from space into the Earth's atmosphere each day. NASA periodically collects some of these particles from the Earth's stratosphere using sticky collectors mounted on NASA's high-flying aircraft. Sometimes, especially when the Earth experiences a known meteor shower, a special opportunity is presented to associate cosmic dust particles with a known source. NASA JSC's Cosmic Dust Collection Program has made special attempts to collect dust from particular meteor showers and asteroid families when flights can be planned well in advance. However, it has rarely been possible to make collections on very short notice. In 2012, the Draconid meteor shower presented that opportunity. The Draconid meteor shower, originating from Comet 21P/Giacobini-Zinner, has produced both outbursts and storms several times during the last century, but the 2012 event was not predicted to be much of a show. Because of these predictions, the Cosmic Dust team had not targeted a stratospheric collection effort for the Draconids, despite the fact that they have one of the slowest atmospheric entry velocities (23 km/s) of any comet shower, and thus offer significant possibilities of successful dust capture. However, radar measurements obtained by the Canadian Meteor Orbit Radar during the 2012 Draconids shower indicated a meteor storm did occur October 8 with a peak at 16:38 (+/-5 min) UTC for a total duration of approximately 2 hours.

  1. The application of x-ray fluorescence and diffraction to the characterization of environmental assessment samples

    International Nuclear Information System (INIS)

    Censullo, A.C.; Briden, F.E.

    1982-01-01

    Some of the results of tests on environmental assessment samples are reported on. The utility of the J.W. Criss fundamental parameters computer program is evaluated for samples in which only one standard per element was used and where the standard matrix did not strictly resemble the unknown matrix. The environmental significance of a sample is dependent not only on its elemental composition, but also on the species or phases which the elements comprise. X-ray powder diffraction may be used to advantage for speciation. Multi-phase environmental assessment samples are amenable to XRD interpretation. Some results of the application of the Joint Committee on Power Diffraction Standards computer interpretatin of typical environmental samples are discussed. They were shown to contribute to the specification of the complex samples that are encountered in environmental assessments

  2. Comparison of semen parameters in samples collected by masturbation at a clinic and at home.

    Science.gov (United States)

    Elzanaty, Saad; Malm, Johan

    2008-06-01

    To investigate differences in semen quality between samples collected by masturbation at a clinic and at home. Cross-sectional study. Fertility center. Three hundred seventy-nine men assessed for infertility. None. Semen was analyzed according to World Health Organization guidelines. Seminal markers of epididymal (neutral alpha-glucosidase), prostatic (prostate-specific antigen and zinc), and seminal vesicle (fructose) function were measured. Two patient groups were defined according to sample collection location: at a clinic (n = 273) or at home (n = 106). Compared with clinic-collected semen, home-collected samples had statistically significantly higher values for sperm concentration, total sperm count, rapid progressive motility, and total count of progressive motility. Semen volume, proportion of normal sperm morphology, neutral alpha-glucosidase, prostate-specific antigen, zinc, and fructose did not differ significantly between groups. An abnormal sperm concentration (masturbation at home compared with at a clinic. This should be taken into consideration in infertility investigations.

  3. k0-INAA for APM samples collected in period of June 2004 - March 2005 and some marine certified reference materials

    International Nuclear Information System (INIS)

    Dung, Ho Manh; Vu, Cao Dong; Y, Truong; Sy, Nguyen Thi

    2006-01-01

    The airborne particulate matter (APM) samples have been collected in 2004 using two types of polycarbonate membrane filter PM 2.5 and PM 2.5-10 at two sites of industrial (Ho Chi Mihn City) and rural (Dateh) regions in south of Vietnam. Three marine certified reference materials have been selected to establish a k0-NAA procedure for marine samples. The concentration of trace multi-element in the samples has been determined by the k 0 -INAA procedure using K o -DALAT software developed in Dalat NRI. About 28 elements in 224 APM samples collected at two areas of Dateh and HCMC of Vietnam in period from June, 2004 to March, 2005 were presented in report. The statistical analysis was applied to the data set to investigate the pollution source at sampling sites. The results proved that the k 0 -NAA on the Dalat research reactor is a reliable and effective analytical technique for characterization of trace multi-element in APM and marine samples for air and marine environmental pollution study in Vietnam. (author)

  4. Handbook: Collecting Groundwater Samples from Monitoring Wells in Frenchman Flat, CAU 98

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Jenny [Desert Research Inst. (DRI), Reno, NV (United States); Lyles, Brad [Desert Research Inst. (DRI), Reno, NV (United States); Cooper, Clay [Desert Research Inst. (DRI), Reno, NV (United States); Hershey, Ron [Desert Research Inst. (DRI), Reno, NV (United States); Healey, John [Desert Research Inst. (DRI), Reno, NV (United States)

    2015-06-01

    Frenchman Flat basin on the Nevada National Security Site (NNSS) contains Corrective Action Unit (CAU) 98, which is comprised of ten underground nuclear test locations. Environmental management of these test locations is part of the Underground Test Area (UGTA) Activity conducted by the U.S. Department of Energy (DOE) under the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended) with the U.S. Department of Defense (DOD) and the State of Nevada. A Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) has been approved for CAU 98 (DOE, 2011). The CADD/CAP reports on the Corrective Action Investigation that was conducted for the CAU, which included characterization and modeling. It also presents the recommended corrective actions to address the objective of protecting human health and the environment. The recommended corrective action alternative is “Closure in Place with Modeling, Monitoring, and Institutional Controls.” The role of monitoring is to verify that Contaminants of Concern (COCs) have not exceeded the Safe Drinking Water Act (SDWA) limits (Code of Federal Regulations, 2014) at the regulatory boundary, to ensure that institutional controls are adequate, and to monitor for changed conditions that could affect the closure conditions. The long-term closure monitoring program will be planned and implemented as part of the Closure Report stage after activities specified in the CADD/CAP are complete. Groundwater at the NNSS has been monitored for decades through a variety of programs. Current activities were recently consolidated in an NNSS Integrated Sampling Plan (DOE, 2014). Although monitoring directed by the plan is not intended to meet the FFACO long-term monitoring requirements for a CAU (which will be defined in the Closure Report), the objective to ensure public health protection is similar. It is expected that data collected in accordance with the plan will support the transition to long-term monitoring at each

  5. 75 FR 44944 - Agency Information Collection Activities; Proposed Collection; Comment Request; Environmental...

    Science.gov (United States)

    2010-07-30

    ... (Rule), were promulgated pursuant to the Antarctic Science, Tourism, and Conservation Act of 1996 (Act... environmental impacts of nongovernmental activities in Antarctica, including tourism, for which the United... to the safety of human life or of ships, aircraft, equipment and facilities of high value, or the...

  6. Investigation of environmental samples by low-level gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, M [Nuclear Engineering and Analytics Rossendorf, Inc., Dresden (Germany); Niese, S [Nuclear Engineering and Analytics Rossendorf, Inc., Dresden (Germany)

    1997-03-01

    The average sample number in our laboratory is about 200 per month (12% technical solid state, 30% geological solid state, 6% geological solid state with low mass, 12% biological, 11% water directly, 25% water after chemical separation, 4% others). In 54% of the measurements the background continuum, and though the detection limit, is determined only by the detector himself and not by the compton continuum from high energy lines in the sample. Some examples in the presented work aim to prove the advantages of gamma ray spectrometry in the underground laboratory Felsenkeller. (orig./DG)

  7. Assessment of DDT levels in selected environmental media and biological samples from Mexico and Central America.

    Science.gov (United States)

    Pérez-Maldonado, Iván N; Trejo, Antonio; Ruepert, Clemens; Jovel, Reyna del Carmen; Méndez, Mónica Patricia; Ferrari, Mirtha; Saballos-Sobalvarro, Emilio; Alexander, Carlos; Yáñez-Estrada, Leticia; Lopez, Dania; Henao, Samuel; Pinto, Emilio R; Díaz-Barriga, Fernando

    2010-03-01

    Taking into account the environmental persistence and the toxicity of DDT, the Pan American Health Organization (PAHO) organized a surveillance program in Mesoamerica which included the detection of residual DDT in environmental (soil) and biological samples (fish tissue and children's blood). This program was carried out in communities from Mexico, Guatemala, El Salvador, Honduras, Nicaragua, Costa Rica and Panama. This paper presents the first report of that program. As expected, the results show that the levels for [summation operator] DDT in soil (outdoor or indoor) and fish samples in the majority of the locations studied are below guidelines. However, in some locations, we found children with high concentrations of DDT as in Mexico (mean level 50.2 ng/mL). Furthermore, in some communities and for some matrices, the DDT/DDE quotient is higher than one and this may reflect a recent DDT exposure. Therefore, more efforts are needed to avoid exposure and to prevent the reintroduction of DDT into the region. In this regard it is important to know that under the surveillance of PAHO and with the support of UNEP, a regional program in Mesoamerica for the collection and disposal of DDT and other POPs stockpiles is in progress. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  8. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE

  9. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  10. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE.

  11. Lepidosaurian diversity in the Mesozoic-Palaeogene: the potential roles of sampling biases and environmental drivers

    Science.gov (United States)

    Cleary, Terri J.; Benson, Roger B. J.; Evans, Susan E.; Barrett, Paul M.

    2018-03-01

    Lepidosauria is a speciose clade with a long evolutionary history, but there have been few attempts to explore its taxon richness through time. Here we estimate patterns of terrestrial lepidosaur genus diversity for the Triassic-Palaeogene (252-23 Ma), and compare observed and sampling-corrected richness curves generated using Shareholder Quorum Subsampling and classical rarefaction. Generalized least-squares regression (GLS) is used to investigate the relationships between richness, sampling and environmental proxies. We found low levels of richness from the Triassic until the Late Cretaceous (except in the Kimmeridgian-Tithonian of Europe). High richness is recovered for the Late Cretaceous of North America, which declined across the K-Pg boundary but remained relatively high throughout the Palaeogene. Richness decreased following the Eocene-Oligocene Grande Coupure in North America and Europe, but remained high in North America and very high in Europe compared to the Late Cretaceous; elsewhere data are lacking. GLS analyses indicate that sampling biases (particularly, the number of fossil collections per interval) are the best explanation for long-term face-value genus richness trends. The lepidosaur fossil record presents many problems when attempting to reconstruct past diversity, with geographical sampling biases being of particular concern, especially in the Southern Hemisphere.

  12. Natural and anthropogenic {sup 236}U in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Steier, Peter [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria)], E-mail: peter.steier@univie.ac.at; Bichler, Max [Atominstitut der Osterreichischen Universitaeten, Technische Universitaet Wien, Stadionallee 2, Wien A-1020 (Austria); Keith Fifield, L. [Department of Nuclear Physics, RSPhysSE, Australian National University, Canberra, ACT 0200 (Australia); Golser, Robin; Kutschera, Walter; Priller, Alfred [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); Quinto, Francesca [Dipartimento di Scienze Ambientali, Seconda Universita di Napoli, via Vivaldi 43, Caserta 81100 (Italy); Richter, Stephan [Euopean Commission, Directorate-General Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Srncik, Michaela [Institut fuer Anorganische Chemie, Universitaet Wien, Waehringer Strasse 42, A-1090 Wien (Austria); Terrasi, Philippo [Dipartimento di Scienze Ambientali, Seconda Universita di Napoli, via Vivaldi 43, Caserta 81100 (Italy); Wacker, Lukas [Institute for Particle Physics, HPK H25, Schafmattstrasse 20, CH-8093 Zuerich (Switzerland); Wallner, Anton [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); Wallner, Gabriele [Institut fuer Anorganische Chemie, Universitaet Wien, Waehringer Strasse 42, A-1090 Wien (Austria); Wilcken, Klaus M. [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 OQF (United Kingdom); Maria Wild, Eva [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria)

    2008-05-15

    The interaction of thermal neutrons with {sup 235}U results in fission with a probability of {approx}85% and in the formation of {sup 236}U (t{sub 1/2} = 2.3 x 10{sup 7} yr) with a probability of {approx}15%. While anthropogenic {sup 236}U is, therefore, present in spent nuclear fuel at levels of {sup 236}U/U up to 10{sup -2}, the expected natural ratios in the pre-anthropogenic environment range from 10{sup -14} to 10{sup -10}. At VERA, systematic investigations suggest a detection limit below {sup 236}U/U = 5 x 10{sup -12} for samples of 0.5 mg U, while chemistry blanks of {approx}2 x 10{sup 7} atoms {sup 236}U per sample limit the sensitivity for smaller samples. We have found natural isotopic ratios in uranium reagents separated before the onset of human nuclear activities, in uranium ores from various origins and in water from a subsurface well in Bad Gastein, Austria. Anthropogenic contamination was clearly visible in soil and rivulet samples from Salzburg, Austria, whereas river sediments from Garigliano river (Southern Italy) were close to the detection limit. Finally, our natural in-house standard Vienna-KkU was calibrated against a certified reference material (IRMM REIMEP-18 A)

  13. Total Decomposition of Environmental Radionuclide Samples with a Microwave Oven

    International Nuclear Information System (INIS)

    Ramon Garcia, Bernd Kahn

    1998-01-01

    Closed-vessel microwave assisted acid decomposition was investigated as an alternative to traditional methods of sample dissolution/decomposition. This technique, used in analytical chemistry, has some potential advantages over other procedures. It requires less reagents, it is faster, and it has the potential of achieving total dissolution because of higher temperatures and pressures

  14. GY SAMPLING THEORY IN ENVIRONMENTAL STUDIES 2: SUBSAMPLING ERROR MEASUREMENTS

    Science.gov (United States)

    Sampling can be a significant source of error in the measurement process. The characterization and cleanup of hazardous waste sites require data that meet site-specific levels of acceptable quality if scientifically supportable decisions are to be made. In support of this effort,...

  15. Planning Considerations Related to Collecting and Analyzing Samples of the Martian Soils

    Science.gov (United States)

    Liu, Yang; Mellon, Mike T.; Ming, Douglas W.; Morris, Richard V.; Noble, Sarah K.; Sullivan, Robert J.; Taylor, Lawrence A.; Beaty, David W.

    2014-01-01

    The Mars Sample Return (MSR) End-to-End International Science Analysis Group (E2E-iSAG [1]) established scientific objectives associ-ated with Mars returned-sample science that require the return and investigation of one or more soil samples. Soil is defined here as loose, unconsolidated materials with no implication for the presence or absence of or-ganic components. The proposed Mars 2020 (M-2020) rover is likely to collect and cache soil in addition to rock samples [2], which could be followed by future sample retrieval and return missions. Here we discuss key scientific consid-erations for sampling and caching soil samples on the proposed M-2020 rover, as well as the state in which samples would need to be preserved when received by analysts on Earth. We are seeking feedback on these draft plans as input to mission requirement formulation. A related planning exercise on rocks is reported in an accompanying abstract [3].

  16. ICP-MS applications for the analysis of geological materials and environmental samples

    International Nuclear Information System (INIS)

    Bendl, J.

    1997-01-01

    This work deals with applications of inductively coupled plasma - mass spectrometry applications for the analysis of geological materials and environmental samples. There are instrumentation, calibration, alternatives of sample introduction, interferences, trace elements analysis, rare earth elements and uranium and thorium, precious metals, isotopic analysis and environmental analysis discussed

  17. The sampling and analysing methods of radionuclides used in the Nordic countries for environmental samples

    International Nuclear Information System (INIS)

    Taipale, Tarja K.

    1985-01-01

    The Radioecology Group under the Nordic Liaison Committee for Atomic Energy has considered it to be of great importance to improve the comparability of environmental radioactivity measurements in the Nordic countries, a basic requirement for co-ordinated research programmes. In case of emergency, good comparability between the results obtained will be required for mutual assistance. Therefore several intercomparison exercises have been carried out between the laboratories measuring environmental radioactivity. The exercises have proved very useful and have led to a more comprehensive and systematic survey of the environmental measurement methodology used so far by the Nordic laboratories. Furthermore it is considered necessary to make some recommendations or even to reach an agreement on how to present the results in order to make the comparison of, at least, monitoring data easier. This report is based on the answers received from the participating laboratories to a questionnaire sent by the Finnish Centre for Radiation and Nuclear Safety, Helsinki

  18. The sampling and analysing methods of radionuclides used in the Nordic countries for environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Taipale, Tarja K [ed.

    1985-01-01

    The Radioecology Group under the Nordic Liaison Committee for Atomic Energy has considered it to be of great importance to improve the comparability of environmental radioactivity measurements in the Nordic countries, a basic requirement for co-ordinated research programmes. In case of emergency, good comparability between the results obtained will be required for mutual assistance. Therefore several intercomparison exercises have been carried out between the laboratories measuring environmental radioactivity. The exercises have proved very useful and have led to a more comprehensive and systematic survey of the environmental measurement methodology used so far by the Nordic laboratories. Furthermore it is considered necessary to make some recommendations or even to reach an agreement on how to present the results in order to make the comparison of, at least, monitoring data easier. This report is based on the answers received from the participating laboratories to a questionnaire sent by the Finnish Centre for Radiation and Nuclear Safety, Helsinki.

  19. Using Environmental Variables for Studying of the Quality of Sampling in Soil Mapping

    Directory of Open Access Journals (Sweden)

    A. Jafari

    2016-02-01

    profiles, which were then described, sampled, analyzed and classified according to the USDA soil classification system (16. The basic rationale is to set up a hypercube, the axes of which are the quantiles of rasters of environmental covariates, e.g., digital elevation model. Sampling evaluation was made using the HELS algorithm. This algorithm was written based on the study of Carre et al., 2007 (3 and run in R. Results and Discussion: The covariate dataset is represented by elevation, slope and wetness index (Table 2. All data layers were interpolated to a common grid of 30 m resolution. The size of the raster layer is 421 by 711 grid cells. Each of the three covariates is divided into four quantiles (Table 2. The hypercube character space has 43, i.e. 64 strata (Figure 5. The average number of grid cells within each stratum is therefore 4677 grid cells. The map of the covariate index (Figure 6 shows some patterns representative of the covariate variability. The values of the covariate index range between 0.0045 and 5.95. This means that some strata are very dense compared to others. This index allows us to explain if high or low relative weight of the sampling units (see below is due to soil sampling or covariate density. The strata with the highest density are in the areas with high geomorphology diversity. It means that geomorphology processes can cause the diversity and variability and it is in line with the geomorphology map (Figure 2. Of the 64 strata, 30.4% represent under-sampling, 60.2% represent adequate sampling and 9.4% represent over-sampling. Regarding the covariate index, most of the under-sampling appears in the high covariate index, where soil covariates are then highly variable. Actually, it is difficult to collect field samples in these highly variable areas (Figure 7. Also, most of the over-sampling was observed in areas with alow covariate index (Figure 7. We calculated the weights of all the sampling units and showed the results in Figure 8. One 64

  20. Compendium of Environmental Sustainability Indicator Collections: 2006 National Footprint Accounts (NFA)

    Data.gov (United States)

    National Aeronautics and Space Administration — The 2006 National Footprint Accounts (NFA) portion of the Compendium of Environmental Sustainability Indicator Collections, version 1.1 is a data set that measures...

  1. Resonance ionization mass spectrometry system for measurement of environmental samples

    International Nuclear Information System (INIS)

    Pibida, L.; McMahon, C.A.; Noertershaeuser, W.; Bushaw, B.A.

    2002-01-01

    A resonance ionization mass spectrometry (RIMS) system has been developed at the National Institute of Standards and Technology (NIST) for sensitive and selective determination of radio-cesium in the environment. The overall efficiency was determined to be 4x10-7 with a combined (laser and mass spectrometer) selectivity of 108 for both 135Cs and 137Cs with respect to 133Cs. RIMS isotopic ratio measurements of 135Cs/ 137Cs were performed on a nuclear fuel burn-up sample and compared to measurements on a similar system at Pacific Northwest National Laboratory (PNNL) and to conventional thermal ionization mass spectrometry (TIMS). Results of preliminary RIMS investigations on a freshwater lake sediment sample are also discussed

  2. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    Science.gov (United States)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in

  3. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hong-geller, Elizabeth [Los Alamos National Laboratory; Valdez, Yolanda E [Los Alamos National Laboratory; Shou, Yulin [Los Alamos National Laboratory; Yoshida, Thomas M [Los Alamos National Laboratory; Marrone, Babetta L [Los Alamos National Laboratory; Dunbar, John [Los Alamos National Laboratory

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  4. Application of WSP method in analysis of environmental samples

    International Nuclear Information System (INIS)

    Stacho, M.; Slugen, V.; Hinca, R.; Sojak, S.; Krnac, S.

    2014-01-01

    Detection of activity in natural samples is specific especially because of its low level and high background interferences. Reduction of background interferences could be reached using low background chamber. Measurement geometry in shape of Marinelli beaker is commonly used according to low level of activity in natural samples. The Peak Net Area (PNA) method is the world-wide accepted technique for analysis of gamma-ray spectra. It is based on the net area calculation of the full energy peak, therefore, it takes into account only a fraction of measured gamma-ray spectrum. On the other hand, the Whole Spectrum Processing (WSP) approach to the gamma analysis makes possible to use entire information being in the spectrum. This significantly raises efficiency and improves energy resolution of the analysis. A principal step for the WSP application is building up the suitable response operator. Problems are put in an appearance when suitable standard calibration sources are unavailable. It may be occurred in the case of large volume samples and/or in the analysis of high energy range. Combined experimental and mathematical calibration may be a suitable solution. Many different detectors have been used to register the gamma ray and its energy. HPGe detectors produce the highest resolution commonly available today. Therefore they are they the most often used detectors in natural samples activity analysis. Scintillation detectors analysed using PNA method could be also used in simple cases, but for complicated spectra are practically inapplicable. WSP approach improves resolution of scintillation detectors and expands their applicability. WSP method allowed significant improvement of the energetic resolution and separation of "1"3"7Cs 661 keV peak from "2"1"4Bi 609 keV peak. At the other hand the statistical fluctuations in the lower part of the spectrum highlighted by background subtraction causes that this part is still not reliably analyzable. (authors)

  5. Self-attenuation of gamma rays during radioactivity concentration analysis of environmental samples

    International Nuclear Information System (INIS)

    Watson, D.; Dharmasiri, J.; Akber, R.

    2001-01-01

    Gamma spectroscopy using HPGe detector systems is a readily used technique for routine analysis of radioactivity in environmental samples. The systems are generally calibrated using standards of known radioactivity and composition. Radioactivity in environmental samples is generally distributed in the bulk of the material. When a sample of finite thickness is analysed through gamma spectroscopy, a proportion of the gamma rays emitted from the sample is either stopped or scattered from the sample material itself. These processes of self-absorption and self-attenuation depend upon the physical and elemental composition of the sample and the energy of the gamma radiation. Since environmental samples vary in composition, instrument calibration using a fixed matrix composition may not be valid for a diversity of samples. We selected and analysed five sample matrices to investigate the influence of self-absorption and self-attenuation in environmental samples. Our selection consisted of bentonite and kaolin representing clay, quartz representing silica, ash representing prepared biota, and analytical grade MnO 2 representing a co-precipitant used for extractive radioactivity from aqueous samples. Our findings show that within 5% of uncertainty the silica based standards can be used to cover the environmental samples of varying clay (silica content). The detection efficiency for ash and MnO 2 could be different particularly in the 30 - 100 keV energy range. The differences in sample behaviour can be explained on the basis of atomic number, mass number and density

  6. Human blood RNA stabilization in samples collected and transported for a large biobank

    Science.gov (United States)

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  7. The use of at-sea-sampling data to dissociate environmental variability in Norway lobster (Nephrops norvegicus) catches to improve resource efficiency

    DEFF Research Database (Denmark)

    Feekings, Jordan P.; Christensen, Asbjørn; Jonsson, Patrik

    2014-01-01

    The primary aim of this study was to determine whether the information collected as part of the at-sea-sampling program could be used to identify hydrographical and environmental variables that are influential on catch rates of Norway lobster. Ultimately, we wanted to know whether environmental...

  8. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    Science.gov (United States)

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  9. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  10. Promoting Pro-Environmental Behaviour: Collection of Used Batteries by Secondary School Pupils

    Science.gov (United States)

    Rioux, Liliane

    2011-01-01

    This research is based on Kollmuss and Agyeman's mode, and aims to determine if the prerequisites for pro-environmental behaviour, such as the collection of used batteries at school, are ethical, cognitive and environmental. A questionnaire/opinionnaire was given to 102, 14-17-year-olds to gather data on: (1) their current recycling habits, (2)…

  11. Advanced Curation Activities at NASA: Implications for Astrobiological Studies of Future Sample Collections

    Science.gov (United States)

    McCubbin, F. M.; Evans, C. A.; Fries, M. D.; Harrington, A. D.; Regberg, A. B.; Snead, C. J.; Zeigler, R. A.

    2017-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. The Directive goes on to define Curation as including documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach. Here we briefly describe NASA's astromaterials collections and our ongoing efforts related to enhancing the utility of our current collections as well as our efforts to prepare for future sample return missions. We collectively refer to these efforts as advanced curation.

  12. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Active Collection of Land Cover Sample Data from Geo-Tagged Web Texts

    Directory of Open Access Journals (Sweden)

    Dongyang Hou

    2015-05-01

    Full Text Available Sample data plays an important role in land cover (LC map validation. Traditionally, they are collected through field survey or image interpretation, either of which is costly, labor-intensive and time-consuming. In recent years, massive geo-tagged texts are emerging on the web and they contain valuable information for LC map validation. However, this kind of special textual data has seldom been analyzed and used for supporting LC map validation. This paper examines the potential of geo-tagged web texts as a new cost-free sample data source to assist LC map validation and proposes an active data collection approach. The proposed approach uses a customized deep web crawler to search for geo-tagged web texts based on land cover-related keywords and string-based rules matching. A data transformation based on buffer analysis is then performed to convert the collected web texts into LC sample data. Using three provinces and three municipalities directly under the Central Government in China as study areas, geo-tagged web texts were collected to validate artificial surface class of China’s 30-meter global land cover datasets (GlobeLand30-2010. A total of 6283 geo-tagged web texts were collected at a speed of 0.58 texts per second. The collected texts about built-up areas were transformed into sample data. User’s accuracy of 82.2% was achieved, which is close to that derived from formal expert validation. The preliminary results show that geo-tagged web texts are valuable ancillary data for LC map validation and the proposed approach can improve the efficiency of sample data collection.

  14. Multi-element composition of historical lichen collections and bark samples, indicators of changing atmospheric conditions

    Science.gov (United States)

    Purvis, O. W.; Chimonides, P. D. J.; Jeffries, T. E.; Jones, G. C.; Rusu, A.-M.; Read, H.

    Thirty six element signatures were compared in historical Parmelia sulcata samples from the Natural History Museum herbarium collected over the period 1797-1967 with those recorded in the same species and tree bark sampled in 2000 from Burnham Beeches, lying 40 km west of London. Nineteen elements reached highest concentrations in herbarium samples, consistent with a pollution legacy and dust contamination in the herbarium. Healthy Parmelia sampled east and down-wind of London at a farm during peak SO 2 emissions in 1967 contained highest V, Ni, Zn, Cd, Se, Ge contents, supporting derivation from fuel combustion; the same sample was previously determined as having a low δ34S and high S and N contents. Lowest V, Co, Ni, Cu, Zn, Sn, Ba, Pb, Mo, Sb, Li, B, Cs, U, Th, Ga contents were recorded in a sample with a high δ34S and low S content collected in 1887 from a remote region from Ross-shire, Scotland. Se and Cd enrichment, never-the-less suggest a transboundary pollution influence. Lichen Pb concentrations from Burnham Beeches were amongst the lowest recorded in spite of lichens being collected close to roads. Herbarium samples help interpret changes in element deposition where few data exist, in spite of dust contamination.

  15. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    Science.gov (United States)

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  16. Determination of multi-element in marine sediment samples collected in Angola by the k0-NAA technique

    International Nuclear Information System (INIS)

    Teixeira, M.C.P.; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Thanh Binh; Vuong Huu Tan

    2006-01-01

    The marine sediment samples were designed to collect in Angola for marine environmental pollution study. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on Dalat research reactor has been developed to determine of multi-element in the Angola marine sediment samples. The samples were irradiated in cell 7-1 for short- and middle-lived nuclides and rotary specimen rack for long-lived nuclides. The irradiation facilities were characterized for neutron spectrum parameters and post-activated samples were measured on the calibrated gamma-ray spectrometers using HPGe detectors. The analytical results for 9 marine sediment samples with 27 elements: Al, As, Br, Ca, Ce,Cl, Co, Cs, Dy, Fe, Hf, I, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Th, Ti, U, V and Zn in term of mean concentration, standard deviation and their content range are shown in the report. The analytical quality assurance was done by analysis of a Japan's certified reference material namely marine sediment NMIJ-CRM-7302a. These preliminary results revealed that the k 0 -NAA technique on the Dalat research reactor is a good analytical technique for determination of multi-element in the marine sediment samples. Some heavy metals and trace elements determined in this work possibly connected to the human activities at the sampling region. (author)

  17. A comparison of results for samples collected with bailers constructed of different materials

    International Nuclear Information System (INIS)

    Thomey, N.; Ogle, R.; Jackson, J.

    1992-01-01

    A bailer is one of the most common sampling devices used to collect ground water samples. Bailers constructed from various materials are available; teflon, polyvinyl chloride (PVC), polyethylene, and stainless steel are all commonly used. It is widely recognized that sample results can be affected by the material from which the bailer is constructed. Teflon and stainless steel are usually recommended based upon their inert properties. The cost of these bailers is significantly higher than other types. For the purposes of petroleum storage tank investigations, sampling devices that would not compromise sample quality but be more economical than teflon or stainless steel would be especially desirable. Water samples were collected using the different types of bailers; teflon, stainless steel, PVC, and polyethylene. Split samples were analyzed for benzene, toluene, ethylbenzene, total xylenes, and Total Petroleum Hydrocarbons. The analytical results were compared to determine if differences were due to normal analytical variances or due to interaction of the sample with the sampling device. No difference was noted in the results which were obtained

  18. Collection and preparation of wet and dry stream-sediment samples

    International Nuclear Information System (INIS)

    Puchlik, K.

    1977-03-01

    Lawrence Livermore Laboratory is responsible for the Hydrogeochemistry and Stream Sediment Reconnaissance (HSSR) program for uranium in the seven far western states. The work thus far has concentrated on the arid to semi-arid regions of the West and this paper discusses the collection and preparation of sediment samples in the Basin and Range province. The sample collection and preparation procedures described here may not be applicable to other parts of the far western states or other areas. These procedures also differ somewhat from those used by the other three laboratories involved in the HSSR program

  19. Survey of elemental concentrations in lichen samples collected from Sao Paulo State

    International Nuclear Information System (INIS)

    Saiki, M.; Horimoto, L.K.; Vasconcellos, M.B.A.; Coccaro, D.M.B.; Marcelli, M.P.

    2001-01-01

    Samples of the lichen Canoparmelia texana collected in seven different sites of Sao Paulo State and one site of the Parana State were analysed by neutron activation analysis in order to obtain information on the air quality in these regions and also to select a region of interest for the evaluation of baseline level of elements in lichen species. Concentrations of the elements Al, As, Br, Ca, Cd, Cl, Co, Cs, Fe, Hf, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Ti, Th, U, V, Zn and lanthanides were determined and a preliminary comparisons was made between the results obtained for samples collected in different sites. (author)

  20. Simultaneous PIXE and PIGE analyses of aerosol samples collected in urban areas

    International Nuclear Information System (INIS)

    Boni, C.; Caruso, E.; Cereda, E.; Marcazzan, G.M.; Redaelli, P.; Bacci, P.

    1988-01-01

    The paper concerns the simultaneous PIXE (Particle Induced X-ray Emission) and PIGE (Proton Induced Gamma-ray Emission) analyses of aerosol samples collected in urban areas. The results show that PIGE can detect Li, F, Na, Al, and Si in fly ashes and F, Na, Al and Si in atmospheric aerosol. The PIXE-PIGE technique has also been applied to 80 samples of atmospheric particular matter collected above Milan during the winter and summer months of 1986/7, and the average values of concentrations and enrichment factors are given for the detected elements. (U.K.)

  1. A note on {sup 207}Bi in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bossew, P. [European Commission, DG Joint Research Centre, Institute of Environment and Sustainability, Radioactivity Environmental Monitoring Group. Via Fermi 1, I-21020 Ispra, Vatican City State, Holy See (Italy)]. E-mail: peter.bossew@jrc.it; Lettner, H. [Institute of Physics and Biophysics, University of Salzburg, Hellbrunner Strasse 34, A-5020 Salzburg (Austria)]. E-mail: herbert.lettner@sbg.ac.at; Hubmer, A. [Institute of Physics and Biophysics, University of Salzburg, Hellbrunner Strasse 34, A-5020 Salzburg (Austria)

    2006-07-01

    Traces of the radionuclide {sup 207}Bi were identified in soil and cryoconite (glacier sediment) samples from Alpine regions of Austria. This nuclide has been produced in thermonuclear explosions mainly in the early 1960s and subsequently dispersed in the atmosphere. Activity concentrations up to 22 Bq/kg d.m. have been found. The ratio {sup 207}Bi:{sup 137}Cs(global fallout) equals (1.70 {+-} 0.12)10{sup -3}, which is in accordance with literature data. When low levels of {sup 207}Bi are assessed by gamma spectrometry, corrections must be made for a gamma line produced in the lead shield by neutron activation due to cosmic neutrons.

  2. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  3. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    Science.gov (United States)

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  4. Radon exhalation rates from soil and sand samples collected from the vicinity of Yamuna river

    International Nuclear Information System (INIS)

    Garg, A.K.; Sushil Kumar; Chauhan, Pooja; Chauhan, R.P.

    2011-01-01

    Soil, sand and stones are the most popular building materials for Indian dwellings. Radon is released into ambient air from these materials due to ubiquitous uranium and radium in them, thus increasing the airborne radon concentration. The radioactivity in sand and soils is related to radioactivity in the rocks from which they are formed. These materials contain varying amount of uranium. In the present investigation, the radon emanated from soil and sand samples from different locations in the vicinity of Yamuna river has been estimated. The samples have been collected from different locations near the Yamuna river. The samples collecting sites are from Yamunanagar in Haryana to Delhi. The radon concentration in different samples has been calculated, based upon the data, the mass and the surface exhalation rates of radon emanated from them have also been calculated

  5. Application of bar codes to the automation of analytical sample data collection

    International Nuclear Information System (INIS)

    Jurgensen, H.A.

    1986-01-01

    The Health Protection Department at the Savannah River Plant collects 500 urine samples per day for tritium analyses. Prior to automation, all sample information was compiled manually. Bar code technology was chosen for automating this program because it provides a more accurate, efficient, and inexpensive method for data entry. The system has three major functions: sample labeling is accomplished at remote bar code label stations composed of an Intermec 8220 (Intermec Corp.) interfaced to an IBM-PC, data collection is done on a central VAX 11/730 (Digital Equipment Corp.). Bar code readers are used to log-in samples to be analyzed on liquid scintillation counters. The VAX 11/730 processes the data and generates reports, data storage is on the VAX 11/730 and backed up on the plant's central computer. A brief description of several other bar code applications at the Savannah River Plant is also presented

  6. Efficacy of passive sampler collection for atmospheric NO2 isotopes under simulated environmental conditions.

    Science.gov (United States)

    Coughlin, Justin G; Yu, Zhongjie; Elliott, Emily M

    2017-07-30

    Nitrogen oxides or NO x (NO x = NO + NO 2 ) play an important role in air quality, atmospheric chemistry, and climate. The isotopic compositions of anthropogenic and natural NO 2 sources are wide-ranging, and they can be used to constrain sources of ambient NO 2 and associated atmospheric deposition of nitrogen compounds. While passive sample collection of NO 2 isotopes has been used in field studies to determine NO x source influences on atmospheric deposition, this approach has not been evaluated for accuracy or precision under different environmental conditions. The efficacy of NO 2 passive sampler collection for NO 2 isotopes was evaluated under varied temperature and relative humidity (RH) conditions in a dynamic flux chamber. The precision and accuracy of the filter NO 2 collection as nitrite (NO 2 - ) for isotopic analysis were determined using a reference NO 2 gas tank and through inter-calibration with a modified EPA Method 7. The bacterial denitrifer method was used to convert 20 μM of collected NO 2 - or nitrate (NO 3 - ) into N 2 O and was carried out on an Isoprime continuous flow isotope ratio mass spectrometer. δ 15 N-NO 2 values determined from passive NO 2 collection, in conditions of 11-34 °C, 1-78% RH, have an overall accuracy and precision of ±2.1 ‰, and individual run precision of ±0.6 ‰. δ 18 O-NO 2 values obtained from passive NO 2 sampler collection, under the same conditions, have an overall precision of ± 1.3 ‰. Suitable conditions for passive sampler collection of NO 2 isotopes are in environments ranging from 11 to 34 °C and 1 to 78% RH. The passive NO 2 isotope measurement technique provides an accurate method to determine variations in atmospheric δ 15 N-NO 2 values and a precise method for determining atmospheric δ 18 O-NO 2 values. The ability to measure NO 2 isotopes over spatial gradients at the same temporal resolution provides a unique perspective on the extent and seasonality of fluctuations in atmospheric NO 2

  7. Agri-Environmental Resource Management by Large-Scale Collective Action: Determining KEY Success Factors

    Science.gov (United States)

    Uetake, Tetsuya

    2015-01-01

    Purpose: Large-scale collective action is necessary when managing agricultural natural resources such as biodiversity and water quality. This paper determines the key factors to the success of such action. Design/Methodology/Approach: This paper analyses four large-scale collective actions used to manage agri-environmental resources in Canada and…

  8. Organising Collective Action for Effective Environmental Management and Social Learning in Wales

    Science.gov (United States)

    Mills, Jane; Gibbon, David; Ingram, Julie; Reed, Matt; Short, Christopher; Dwyer, Janet

    2011-01-01

    The paper explored key factors that might lead to successful agri-environmental social learning and collective action in order to deliver landscape-scale resource management within agri-environment schemes. Using the theory of collective action as an analytical framework the paper examined findings from in-depth interviews with 20 members of two…

  9. Sources of variability in collection and preparation of paint and lead-coating samples.

    Science.gov (United States)

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  10. A simple and novel method for retrieval of Pasteurellaceae from swab samples collected in the field

    DEFF Research Database (Denmark)

    Hansen, Mie J; Bertelsen, Mads F; Dietz, Rune

    2013-01-01

    and stored at -20°C. As a control study, 15 samples were collected from the oral cavity of a captive brown bear. One was immediately plated, while the remaining 12 swabs were stored at -20°C for 7 days and multiples of 30 days up to 330 days prior to plating. Two samples were stored without the medium for 7......Traditionally it has been difficult or impossible to collect and preserve bacterial samples of especially fastidious bacteria in mixed primary cultures, unless the samples could be transported to a laboratory within approximately 24 h. Therefore, a simple novel method for preserving swab samples...... until bacterial isolation can be completed in the laboratory was developed and evaluated. Pasteurellaceae bacteria were used as a representative for fastidious bacteria. A 7.5% glucose serum medium was used as freeze medium. Swab samples were soaked in the medium a maximum of 2 h after collection...

  11. o-TOF ICPMS analysis of environmental, food and biological samples

    International Nuclear Information System (INIS)

    Krejcova, A.; Cernohorsky, T.; Ludvikova, I.; Pouzar, M.; Capova, L.

    2009-01-01

    Full text: o-TOF ICPMS was used for inorganic analysis of environmental, food and biological samples. The method validity was proved by analysis of spiked samples, reference materials, by determination without/with internal standards and the standard addition technique. The technique was shown to be powerful, and reliable for analysis of the samples mentioned, and high sample throughput enables environmental or biological screening studies. Independent of the number of elements analyzed, complete analysis and whole mass spectra are gained from a small sample amount in a very short time. (author)

  12. Environmental sampling plan for Kwajalein Atoll Lagoon: 2017 Kwajalein sampling event

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, T. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-07-01

    Since the early 1980s, the U.S DOE Marshall Islands Program at LLNL has provided radiological monitoring of the marine and terrestrial environment at nuclear affected atolls in the northern Marshall Islands. The fundamental aim of these studies was to identify the level and distribution of key residual fallout radionuclide in the environment, improve understanding of prevalent radiation exposure pathways, and develop predictive dose assessments for resettled and resettling atoll population groups. These data and information were essential in terms of guiding the development of effective and environmentally protective remedial measures, and promoting potential actions to improve on food safety and security.

  13. An overview of sample preparation procedures for LC-MS multiclass antibiotic determination in environmental and food samples.

    Science.gov (United States)

    Moreno-Bondi, María Cruz; Marazuela, María Dolores; Herranz, Sonia; Rodriguez, Erika

    2009-10-01

    Antibiotics are a class of pharmaceuticals that are of great interest due to the large volumes of these substances that are consumed in both human and veterinary medicine, and due to their status as the agents responsible for bacterial resistance. They can be present in foodstuffs and in environmental samples as multicomponent chemical mixtures that exhibit a wide range of mechanisms of action. Moreover, they can be transformed into different metabolites by the action of microorganisms, as well as by other physical or chemical means, resulting in mixtures with higher ecotoxicities and risks to human health than those of the individual compounds. Therefore, there is growing interest in the availability of multiclass methods for the analysis of antimicrobial mixtures in environmental and food samples at very low concentrations. Liquid chromatography (LC) has become the technique of choice for multiclass analysis, especially when coupled to mass spectrometry (LC-MS) and tandem MS (LC-MS(2)). However, due to the complexity of the matrix, in most cases an extraction step for sample clean-up and preconcentration is required before analysis in order to achieve the required sensitivities. This paper reviews the most recent developments and applications of multiclass antimicrobial determination in environmental and food matrices, emphasizing the practical aspects of sample preparation for the simultaneous extraction of antimicrobials from the selected samples. Future trends in the application of LC-MS-based techniques to multiclass antibiotic analysis are also presented.

  14. Insular Biobjective Routing with Environmental Considerations for a Solid Waste Collection System in Southern Chile

    OpenAIRE

    Daniela S. Arango González; Elias Olivares-Benitez; Pablo A. Miranda

    2017-01-01

    This paper presents a biobjective problem for a solid waste collection system in a set of islands in southern Chile. The first objective minimizes transportation cost and the second one reduces the environmental impact caused by the accumulation of solid waste at the collection points. To solve this problem, biobjective mixed integer linear programming is used. In the model, an itinerary scheme is considered for the visit to the islands. The model decides which collection points are visited p...

  15. Application of the CometChip platform to assess DNA damage in field-collected blood samples from turtles.

    Science.gov (United States)

    Sykora, Peter; Chiari, Ylenia; Heaton, Andrew; Moreno, Nickolas; Glaberman, Scott; Sobol, Robert W

    2018-05-01

    DNA damage has been linked to genomic instability and the progressive breakdown of cellular and organismal homeostasis, leading to the onset of disease and reduced longevity. Insults to DNA from endogenous sources include base deamination, base hydrolysis, base alkylation, and metabolism-induced oxidative damage that can lead to single-strand and double-strand DNA breaks. Alternatively, exposure to environmental pollutants, radiation or ultra-violet light, can also contribute to exogenously derived DNA damage. We previously validated a novel, high through-put approach to measure levels of DNA damage in cultured mammalian cells. This new CometChip Platform builds on the classical single cell gel electrophoresis or comet methodology used extensively in environmental toxicology and molecular biology. We asked whether the CometChip Platform could be used to measure DNA damage in samples derived from environmental field studies. To this end, we determined that nucleated erythrocytes from multiple species of turtle could be successfully evaluated in the CometChip Platform to quantify levels of DNA damage. In total, we compared levels of DNA damage in 40 animals from two species: the box turtle (Terrapene carolina) and the red-eared slider (Trachemys scripta elegans). Endogenous levels of DNA damage were identical between the two species, yet we did discover some sex-linked differences and changes in DNA damage accumulation. Based on these results, we confirm that the CometChip Platform allows for the measurement of DNA damage in a large number of samples quickly and accurately, and is particularly adaptable to environmental studies using field-collected samples. Environ. Mol. Mutagen. 59:322-333, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  16. Identification and assay of radionuclides in the environmental samples following Chernobyl reactor accident

    International Nuclear Information System (INIS)

    Prakash, S.

    1987-01-01

    In India radioactivity was detected from 2 May 1986 onwards. A variety of samples were assayed for radionuclides in the environmental samples originating from the Chernobyl reactor accident. These are: Cotton swipe samples from aircrafts, air filters, milk, goat thyroids, grass, vegetables and tap waters. The results are presented in the paper

  17. Total reflection X-ray fluorescence with synchrotron radiation applied to biological and environmental samples

    International Nuclear Information System (INIS)

    Simabuco, S.M.; Matsumoto, E.; Jesus, E.F.O.; Lopes, R.T.; Perez, C.; Nascimento Filho, V.F.; Costa, R.S.S.; Tavares do Carmo, M.G.; Saunders, C.

    2001-01-01

    Full text: The Total Reflection X-ray Fluorescence has been applied for trace elements in water and aqueous solutions, environmental samples and biological materials after sample preparation and to surface analysis of silicon wafers. The present paper shows some results of applications for rainwater, atmospheric particulate material, colostrum and nuclear samples. (author)

  18. Portable automation of static chamber sample collection for quantifying soil gas flux

    Science.gov (United States)

    The collection of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled in a given time period is limited by the spacing between chambers and the availability of trained research technicians. However, the static chamber method can limit spatial ...

  19. Aspergillus, Penicillium and Talaromyces isolated from house dust samples collected around the world

    NARCIS (Netherlands)

    Visagie, C M; Hirooka, Y; Tanney, J B; Whitfield, E; Mwange, K; Meijer, M; Amend, A S; Seifert, K A; Samson, R A

    As part of a worldwide survey of the indoor mycobiota, dust was collected from nine countries. Analyses of dust samples included the culture-dependent dilution-to-extinction method and the culture-independent 454-pyrosequencing. Of the 7 904 isolates, 2 717 isolates were identified as belonging to

  20. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of Madagascar. Materials and methods: Participants were recruited in a health care center (urban group) and smaller affiliated dispensaries (rural group). They were invited to perform ...

  1. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology...

  2. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Science.gov (United States)

    2010-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§ 864.3260...

  3. Comparative multielement analyses of airborne particulate samples collected in various areas

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Matsuda, Yatsuka; Mizohata, Akira

    1973-01-01

    In order to grasp the characteristic features of the air pollution by particulates in various areas in Japan, multielement analyses by instrumental neutron activation analysis and radioisotope energy dispersive X-ray fluorescence analysis were applied to 31 airborne particulate samples collected in 15 different areas, and the analytical results obtained were compared with one another. All the samples were collected by so-called ''10 micron cut'' samplers, the collection efficiency of which is considered to be 50% at 8μ and nearly zero beyond 10μ. Among the areas in question there are clean seaside areas, heavily industrialized areas, small cities along the Inland Sea or the Pacific Ocean around which industrialization is progressing, a small city having only a big iron work, an area famous for its ceramic industry and so on. The atmospheres over them were found to be quite different not only in pollution extent but also in pollution pattern. (auth.)

  4. A case study of packaging waste collection systems in Portugal - Part II: Environmental and economic analysis.

    Science.gov (United States)

    Pires, Ana; Sargedas, João; Miguel, Mécia; Pina, Joaquim; Martinho, Graça

    2017-03-01

    An understanding of the environmental impacts and costs related to waste collection is needed to ensure that existing waste collection schemes are the most appropriate with regard to both environment and cost. This paper is Part II of a three-part study of a mixed packaging waste collection system (curbside plus bring collection). Here, the mixed collection system is compared to an exclusive curbside system and an exclusive bring system. The scenarios were assessed using life cycle assessment and an assessment of costs to the waste management company. The analysis focuses on the collection itself so as to be relevant to waste managers and decision-makers who are involved only in this step of the packaging life cycle. The results show that the bring system has lower environmental impacts and lower economic costs, and is capable of reducing the environmental impacts of the mixed system. However, a sensitivity analysis shows that these results could differ if the curbside collection were to be optimized. From economic and environmental perspectives, the mixed system has few advantages. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    Science.gov (United States)

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  6. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  7. Pursuit of improvement in uranium bulk analysis at the clear facility for safeguards environmental samples

    International Nuclear Information System (INIS)

    Sakurai, S.; Takahashi, M.; Sakakibara, T.; Magara, M.; Kurosawa, S.; Esaka, F.; Takai, K.; Watanabe, K.; Usuda, S.; Adachi, T.

    2002-01-01

    Full text: In order to contribute to the IAEA strengthened safeguards system, a project started in Japan Atomic Energy Research Institute (JAERI) in 1998. Consequently, a clean room facility called as CLEAR, the Clean Laboratory for Environmental Analysis and Research, was constructed in June 2001 at JAERI Tokai and the analytical techniques of ultra-trace nuclear materials in environmental samples are being developed. As for the bulk analysis, performance of inductively-coupled plasma mass spectrometry (ICP-MS) was mainly examined because sample preparation for ICP-MS is simpler than that for thermal ionization mass spectrometry (TIMS). Interference of polyatomic ion (such as PtAr + ) and coexisting element (such as Na) on the uranium ions, as well as mass bias caused by ICP-MS operating conditions, has been investigated for precise measurement on uranium isotope ratio. The authors have also studied on the uranium blanks during sample treatment process. The blank value below 10 pg uranium per sample treatment was obtained: dominant origins were elution from Teflon vessel surface in acid heating process of the sample to dry up. The work is in progress to minimize the blank. Compared with the process blank and the minimum uranium amount for isotope ratio measurement by ICP-MS (ca. 10 pg for natural uranium), the swipe cotton (Texwipe-304) which is currently used for IAEA Environmental Sampling includes much more amount of natural uranium in several nano-grams. If the amount of uranium collected on Texwipe-304 is small, sensitive and reliable measurement on isotope ratio will be impossible by bulk analysis. The authors are seeking alternative swipe materials with less amount of uranium. Recently, one of the authors devised an effective technique for recovery of uranium-containing particles from Texwipe-304. The technique, named as Vacuum Suction Method, uses a combination of polycarbonate membrane filters and a macro-pipette tip, which is connected to a vacuum pump

  8. Computational environmental ethnography: combining collective sensing and ethnographic inquiries to advance means for reducing environmental footprints

    DEFF Research Database (Denmark)

    Blunck, Henrik; Bouvin, Niels Olof; Entwistle, Johanne Mose

    2013-01-01

    research experiments are attempting to motivate environmental improvements through feedback via, e.g., room displays, web pages or smart phones, based on (smart) metering of energy usage, or for saving energy by automatic control of, e.g., heating, lighting or appliances. However, existing evaluation...

  9. Escherichia coli in settled-dust and air samples collected in residential environments in Mexico City.

    OpenAIRE

    Rosas, I; Salinas, E; Yela, A; Calva, E; Eslava, C; Cravioto, A

    1997-01-01

    Escherichia coli, an important indicator of the presence of fecal material, was isolated from indoor and outdoor environments in Mexico City. The heterogeneity of E. coli was represented by 89 serotypes, most of them coming from settled-dust indoor samples; 21% of them presented antibiotic multiresistance. The numbers of plasmids were higher among the antibiotic-resistant strains. The results of this study suggest that intestinal infections produced by environmental strains could be of more e...

  10. Concentration and characteristics of depleted uranium in biological and water samples collected in Bosnia and Herzegovina

    International Nuclear Information System (INIS)

    Jia Guogang; Belli, Maria; Sansone, Umberto; Rosamilia, Silvia; Gaudino, Stefania

    2006-01-01

    During Balkan conflicts in 1994-1995, depleted uranium (DU) ordnance was employed and was left in the battlefield. Health concern is related to the risk arising from contamination of the environment with DU penetrators and dust. In order to evaluate the impact of DU on the environment and population in Bosnia and Herzegovina, radiological survey of DU in biological and water samples were carried out over the period 12-24 October 2002. The uranium isotopic concentrations in biological samples collected in Bosnia and Herzegovina, mainly lichens, mosses and barks, were found to be in the range of 0.27-35.7 Bq kg -1 for 238 U, 0.24-16.8 Bq kg -1 for 234 U, and 0.02-1.11 Bq kg -1 for 235 U, showing uranium levels to be higher than in the samples collected at the control site. Moreover, the 236 U in some of the samples was detectable. The isotopic ratios of 234 U/ 238 U showed DU to be detectable in many biological samples at most sites examined, but in very low levels. The presence of DU in the biological samples was as a result of DU contamination in air. The uranium concentrations in water samples collected in Bosnia and Herzegovina were found to be in the range of 0.27-16.2 mBq l -1 for 238 U, 0.41-15.6 mBq l -1 for 234 U and 0.012-0.695 mBq l -1 for 235 U, and two water samples were observed to be DU positive; these values are much lower than those in mineral water found in central Italy and below the WHO guideline for public drinking water. From radiotoxicological point of view, at this moment there is no significant radiological risk related to these investigated sites in terms of possible DU contamination of water and/or plants

  11. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.; Williams, Ryan J.; Isenhart, Thomas M.; Hofmockel, Kirsten S.

    2018-01-01

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

  12. Improved explosive collection and detection with rationally assembled surface sampling materials

    Energy Technology Data Exchange (ETDEWEB)

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.; Cinson, Anthony D.; Ewing, Robert G.; Atkinson, David A.; Addleman, R. Shane

    2016-01-01

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

  13. A Systematic Review of Published Respondent-Driven Sampling Surveys Collecting Behavioral and Biologic Data.

    Science.gov (United States)

    Johnston, Lisa G; Hakim, Avi J; Dittrich, Samantha; Burnett, Janet; Kim, Evelyn; White, Richard G

    2016-08-01

    Reporting key details of respondent-driven sampling (RDS) survey implementation and analysis is essential for assessing the quality of RDS surveys. RDS is both a recruitment and analytic method and, as such, it is important to adequately describe both aspects in publications. We extracted data from peer-reviewed literature published through September, 2013 that reported collected biological specimens using RDS. We identified 151 eligible peer-reviewed articles describing 222 surveys conducted in seven regions throughout the world. Most published surveys reported basic implementation information such as survey city, country, year, population sampled, interview method, and final sample size. However, many surveys did not report essential methodological and analytical information for assessing RDS survey quality, including number of recruitment sites, seeds at start and end, maximum number of waves, and whether data were adjusted for network size. Understanding the quality of data collection and analysis in RDS is useful for effectively planning public health service delivery and funding priorities.

  14. GAINS IN PERFORMANCE OF DIFFERENT METHODS OF COLLECTING ENTOMOLOGICAL MATERIALS IN ENVIRONMENTAL AND FAUNAL STUDIES ON COLEOPTERA

    Directory of Open Access Journals (Sweden)

    B. N. Saypulaeva

    2015-01-01

    Full Text Available The aim is to study the effectiveness of methods of collecting entomological materials for further ecological and faunal studies as well as to gain the main evidence in ecological and faunal studies carried out in the field. Collection of the evidence in the field is necessary for the identification of species composition and to study such aspects as the distribution of species, confinement of species to certain habitats, relations with the food objects (trophism, climate, soil and orographic environmental factors.Methodology. We have used the traditional methods of collection (hand picking, pitfall traps, pitfall traps with increased light, light traps, processing and determination of materials. In recent years, the method of collection of soil invertebrates has introduced an innovation. In expeditionary studies in the island of Tyuleny new ways have been tested of using pitfall traps equipped with an incandescent light source. They provide a higher collection efficiency of Entomological materials. List of species composition of the discussed fauna has been composed by modern taxonomy with the use of directories.Results. We have made a comparative analysis of the effectiveness of different methods of collecting entomological materials on Coleoptera (Carabidae, Scarabaeidae, Elateridae, Tenebrionidae for environmental and faunal studies in the area of Irganayskaya arid basin of intramontane Dagestan. Not all species, registered in the studied habitat, have been identified by methods of soil sampling and pitfall traps. The greatest number of species has been identified by manual collection, and the least by soil sampling. The paper shows the effectiveness of different methods of collecting entomofauna against individual families and species of the groups studied.

  15. Qualitative and quantitative analysis of environmental samples by laser-induced breakdown spectrometry

    International Nuclear Information System (INIS)

    Zorov, N B; Popov, A M; Zaytsev, S M; Labutin, T A

    2015-01-01

    The key achievements in the determination of trace amounts of components in environmental samples (soils, ores, natural waters, etc.) by laser-induced breakdown spectrometry are considered. Unique capabilities of this method make it suitable for rapid analysis of metals and alloys, glasses, polymers, objects of cultural heritage, archaeological and various environmental samples. The key advantages of the method that account for its high efficiency are demonstrated, in particular, a small amount of analyzed material, the absence of sample preparation, the possibility of local and remote analysis of either one or several elements. The use of chemometrics in laser-induced breakdown spectrometry for qualitative sample classification is described in detail. Various approaches to improving the figures of merit of quantitative analysis of environmental samples are discussed. The achieved limits of detection for most elements in geochemical samples are critically evaluated. The bibliography includes 302 references

  16. Method validation and uncertainty evaluation of organically bound tritium analysis in environmental sample.

    Science.gov (United States)

    Huang, Yan-Jun; Zeng, Fan; Zhang, Bing; Chen, Chao-Feng; Qin, Hong-Juan; Wu, Lian-Sheng; Guo, Gui-Yin; Yang, Li-Tao; Shang-Guan, Zhi-Hong

    2014-08-01

    The analytical method for organically bound tritium (OBT) was developed in our laboratory. The optimized operating conditions and parameters were established for sample drying, special combustion, distillation, and measurement on a liquid scintillation spectrometer (LSC). Selected types of OBT samples such as rice, corn, rapeseed, fresh lettuce and pork were analyzed for method validation of recovery rate reproducibility, the minimum detection concentration, and the uncertainty for typical low level environmental sample was evaluated. The combustion water recovery rate of different dried environmental sample was kept at about 80%, the minimum detection concentration of OBT ranged from 0.61 to 0.89 Bq/kg (dry weight), depending on the hydrogen content. It showed that this method is suitable for OBT analysis of environmental sample with stable recovery rate, and the combustion water yield of a sample with weight about 40 g would provide sufficient quantity for measurement on LSC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 1993

    International Nuclear Information System (INIS)

    Conrad, R.; Childs, M.; Rivera-Dirks, C.; Coriz, F.

    1995-07-01

    Area G, in Technical Area 54, has been the principle facility at Los Alamos National Laboratory for the storage and disposal of low-level and transuranic (TRU) radioactive wastes since 1957. The current environmental investigation consisted of ESH-19 personnel who collected soil and single-stage water samples around the perimeter of Area G to characterize possible contaminant movement through surface-water runoff. These samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241 (soil only), and cesium 137. The metals, mercury, lead, and barium, were analyzed using x-ray fluorescence

  18. Towards a Mobile Ecogenomic sensor: the Third Generation Environmental Sample Processor (3G-ESP).

    Science.gov (United States)

    Birch, J. M.; Pargett, D.; Jensen, S.; Roman, B.; Preston, C. M.; Ussler, W.; Yamahara, K.; Marin, R., III; Hobson, B.; Zhang, Y.; Ryan, J. P.; Scholin, C. A.

    2016-02-01

    Researchers are increasingly using one or more autonomous platforms to characterize ocean processes that change in both space and time. Conceptually, studying processes that change quickly both spatially and temporally seems relatively straightforward. One needs to sample in many locations synoptically over time, or follow a coherent water mass and sample it repeatedly. However, implementing either approach presents many challenges. For example, acquiring samples over days to weeks far from shore, without human intervention, requires multiple systems to work together seamlessly, and the level of autonomy, navigation and communications needed to conduct the work exposes the complexity of these requirements. We are addressing these challenges by developing a new generation of robotic systems that are primarily aimed at studies of microbial-mediated processes. As a step towards realizing this new capability, we have taken lessons learned from our second-generation Environmental Sample Processor (2G-ESP), a robotic microbiology "lab-in-a-can" and have re-engineered the system for use on a Tethys-class Long Range AUV (LRAUV). The new instrument is called the third-generation ESP (3G-ESP), and its integration with the LRAUV provides mobility and a persistent presence not seen before in microbial oceanography. The 3G-ESP autonomously filters a water sample and then either preserves that material for eventual return to a laboratory, or processes the sample in real-time for further downstream molecular analytical analyses. The 3G ESP modularizes hardware needed for the collection and preparation of a sample from subsequent molecular analyses by the use of self-contained "cartridges". Cartridges currently come in two forms: one for the preservation of a sample, and the other for onboard homogenization and handoff for downstream processing via one or more analytical devices. The 3G-ESP is designed as a stand-alone instrument, and thus could be deployed on a variety of

  19. Determination of natural alpha-emitting isotopes of uranium and thorium in environmental and geological samples

    International Nuclear Information System (INIS)

    Crespo, M.T.

    1996-01-01

    It is described the complete radiochemical procedure used for the determination of uranium and thorium isotopes in environmental and geological samples by alpha spectrometry. Source preparation methods, alpha-counting and spectral analysis are also included

  20. Engineering Task Plan to Expand the Environmental Operational Envelope of Core Sampling

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This Engineering Task Plan authorizes the development of an Alternative Generation and Analysis (AGA). The AGA will determine how to expand the environmental operating envelope during core sampling operations

  1. A review of analytical techniques for the determination of carbon-14 in environmental samples

    International Nuclear Information System (INIS)

    Milton, G.M.; Brown, R.M.

    1993-11-01

    This report contains a brief summary of analytical techniques commonly used for the determination of radiocarbon in a variety of environmental samples. Details of the applicable procedures developed and tested in the Environmental Research Branch at Chalk River Laboratories are appended

  2. Determination of uranium from nuclear fuel in environmental samples using inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Becker, J.S.

    2000-01-01

    As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The 236 U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on inductively coupled plasma quadrupole mass spectrometry with a hexapole collision cell (HEX-ICP-QMS). The figures of merit of the HEX-ICP-QMS were studied with a plasma-shielded torch using different nebulizers (such as an ultrasonic nebulizer (USN) and Meinhard nebulizer) for solution introduction. A 238 U + ion intensity of up to 27000 MHz/ppm in HEX-ICP-QMS with USN was observed by introducing helium into the hexapole collision cell as the collision gas at a flow rate of 10 ml min -1 . The formation rate of uranium hydride ions UH + /U + of 2 x 10 -6 was obtained by using USN with a membrane desolvator. The limit of 236 U/ 238 U ratio determination in 10 μg 1 -1 uranium solution was 3 x 10 -7 corresponding to the detection limit for 236 U of 3 pg 1 -1 . The precision of uranium isotopic ratio measurements in 10 μg 1 -1 laboratory uranium isotopic standard solution was 0.13% ( 235 U/ 238 U) and 0.33% ( 236 U/ 238 U) using a Meinhard nebulizer and 0.45% ( 235 U/ 238 U) and 0.88% ( 236 U/ 238 U) using a USN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the 236 U/ 238 U ratio ranged from 10 -5 to 10 -3 . (orig.)

  3. Method for rapid screening analysis of Sr-90 in edible plant samples collected near Fukushima, Japan

    International Nuclear Information System (INIS)

    Amano, Hikaru; Sakamoto, Hideaki; Shiga, Norikatsu; Suzuki, Kaori

    2016-01-01

    A screening method for measuring 90 Sr in edible plant samples by focusing on 90 Y in equilibrium with 90 Sr is reported. 90 Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. The dissolved oxalate precipitate was loaded on an extraction chromatography resin, and the 90 Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. 90 Sr ( 90 Y) concentration was determined in plant samples collected near the damaged Fukushima Daiichi Nuclear Power Plants with this method. - Highlights: • A screening method for measuring 90 Sr in edible plant samples by focusing on 90 Y in equilibrium with 90 Sr is reported. • 90 Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. • The dissolved oxalate precipitate was loaded on an extraction chromatography resin. • 90 Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. • 90 Sr ( 90 Y) concentration was determined in edible plant samples collected near the damaged Fukushima Daiichi NPPs with this method.

  4. Series: Practical guidance to qualitative research. Part 3: Sampling, data collection and analysis.

    Science.gov (United States)

    Moser, Albine; Korstjens, Irene

    2018-12-01

    In the course of our supervisory work over the years, we have noticed that qualitative research tends to evoke a lot of questions and worries, so-called frequently asked questions (FAQs). This series of four articles intends to provide novice researchers with practical guidance for conducting high-quality qualitative research in primary care. By 'novice' we mean Master's students and junior researchers, as well as experienced quantitative researchers who are engaging in qualitative research for the first time. This series addresses their questions and provides researchers, readers, reviewers and editors with references to criteria and tools for judging the quality of qualitative research papers. The second article focused on context, research questions and designs, and referred to publications for further reading. This third article addresses FAQs about sampling, data collection and analysis. The data collection plan needs to be broadly defined and open at first, and become flexible during data collection. Sampling strategies should be chosen in such a way that they yield rich information and are consistent with the methodological approach used. Data saturation determines sample size and will be different for each study. The most commonly used data collection methods are participant observation, face-to-face in-depth interviews and focus group discussions. Analyses in ethnographic, phenomenological, grounded theory, and content analysis studies yield different narrative findings: a detailed description of a culture, the essence of the lived experience, a theory, and a descriptive summary, respectively. The fourth and final article will focus on trustworthiness and publishing qualitative research.

  5. Green Aspects of Techniques for the Determination of Currently Used Pesticides in Environmental Samples

    OpenAIRE

    Maciej Tankiewicz; Jacek Namieśnik; Jolanta Stocka; Marek Biziuk

    2011-01-01

    Pesticides are among the most dangerous environmental pollutants because of their stability, mobility and long-term effects on living organisms. Their presence in the environment is a particular danger. It is therefore crucial to monitor pesticide residues using all available analytical methods. The analysis of environmental samples for the presence of pesticides is very difficult: the processes involved in sample preparation are labor-intensive and time-consuming. To date, it has been standa...

  6. Speciation of organotin compounds in environmental samples by GC-ICPMS

    International Nuclear Information System (INIS)

    Vahcic, M.; Milacic, R.; Scancar, J.

    2009-01-01

    Full text: Analytical procedure using 15 m GC column was applied for simultaneous speciation of OTCs in various environmental samples. Methyl-, butyl-, phenyl- and octyl- tin species were quantitatively determined. different extraction reagents and conditions were studied. OTCs species were derivatized by NaBEt 4 and extracted into isooctane or hexane. The applied analytical procedure considerably shortened analytical time and enabled simultaneous determination of 12 OTCs in environmental samples. (author)

  7. Evaluation of Brazilian intercomparison program data from 1991 to 1995 of radionuclide assays in environmental samples

    International Nuclear Information System (INIS)

    Vianna, Maria Elizabeth Couto M.; Tauhata, Luiz; Oliveira, Antonio Eduardo de; Oliveira, Josue Peter de; Clain, Almir Faria; Ferreira, Ana Cristina M.

    1998-01-01

    Historical radioanalytical data from the Institute of Radiation Protection and Dosimetry (IRD) national intercomparison program from 1991 to 1995 were analyzed to evaluate the performance of sixteen Brazilian laboratories in radionuclide analyses in environmental samples. Data are comprised of measurements of radionuclides in 435 spiked environmental samples distributed in fifteen intercomparison runs comprised of 955 analyses. The general and specific radionuclide performances of the participating laboratories were evaluated relative to the reference value. Data analysis encourages improvements in beta emitter measurements

  8. Validation of a Sampling Method to Collect Exposure Data for Central-Line-Associated Bloodstream Infections.

    Science.gov (United States)

    Hammami, Naïma; Mertens, Karl; Overholser, Rosanna; Goetghebeur, Els; Catry, Boudewijn; Lambert, Marie-Laurence

    2016-05-01

    Surveillance of central-line-associated bloodstream infections requires the labor-intensive counting of central-line days (CLDs). This workload could be reduced by sampling. Our objective was to evaluate the accuracy of various sampling strategies in the estimation of CLDs in intensive care units (ICUs) and to establish a set of rules to identify optimal sampling strategies depending on ICU characteristics. Analyses of existing data collected according to the European protocol for patient-based surveillance of ICU-acquired infections in Belgium between 2004 and 2012. CLD data were reported by 56 ICUs in 39 hospitals during 364 trimesters. We compared estimated CLD data obtained from weekly and monthly sampling schemes with the observed exhaustive CLD data over the trimester by assessing the CLD percentage error (ie, observed CLDs - estimated CLDs/observed CLDs). We identified predictors of improved accuracy using linear mixed models. When sampling once per week or 3 times per month, 80% of ICU trimesters had a CLD percentage error within 10%. When sampling twice per week, this was >90% of ICU trimesters. Sampling on Tuesdays provided the best estimations. In the linear mixed model, the observed CLD count was the best predictor for a smaller percentage error. The following sampling strategies provided an estimate within 10% of the actual CLD for 97% of the ICU trimesters with 90% confidence: 3 times per month in an ICU with >650 CLDs per trimester or each Tuesday in an ICU with >480 CLDs per trimester. Sampling of CLDs provides an acceptable alternative to daily collection of CLD data.

  9. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    International Nuclear Information System (INIS)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung; Parkhurst, MaryAnn; Hoover, Mark D.

    2009-01-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol

  10. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    Science.gov (United States)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return

  11. Deepwater Horizon MC252 water column data from the Environmental Response Management Application (ERMA) containing workplan cruise samples, plankton trawl surveys, fish surveys, and related data collected between 2000-06-13 and 2011-10-06 for the DWH response in the Northern Gulf of Mexico (NCEI Accession 0163816)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This Archival Information Package (AIP) contains Environmental Resource Management Application (ERMA) GIS layers that represent trawl locations, Southeast Area...

  12. Deepwater Horizon MC252 sea turtle data from the Environmental Response Management Application (ERMA) containing synoptic surveys, turtle telemetry, workplan sample observations and tagging, density grids, direct capture, and probabilities of exposure, and related sea turtle data collected between 1989-11-15 and 2013-11-12 during the DWH response in the Northern Gulf of Mexico (NCEI Accession 0163813)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This Archival Information Package (AIP) contains Environmental Resource Management Application (ERMA) GIS layers that include turtle survey overflight observations,...

  13. Deepwater Horizon MC252 oyster data from the Environmental Response Management Application (ERMA) containing oyster recruitment sampling results, estimates of subtidal habitat, percent cover, nearshore and subtidal abundance data, and other related datasets collected from 2009-01-01 to 2015-01-01 in the Northern Gulf of Mexico (NCEI Accession 0163812)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This Archival Information Package (AIP) contains Environmental Resource Management Application (ERMA) GIS layers that represent oyster recruitment and abundance...

  14. Joint sampling programme-Verification of data obtained in environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lauria, D.C. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)], E-mail: dejanira@ird.gov.br; Martins, N.S.F.; Vasconcellos, M.L.H.; Zenaro, R.; Peres, S.S.; Pires do Rio, M.A. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2008-11-15

    The objective of the Environmental Radiological Monitoring Control programme carried out by the Institute of Radiation Protection and Dosimetry (IRD) in Brazil is to verify the licensee's compliance with the requirements for environmental monitoring of Brazilian facilities. The Joint Sampling Programme (JSP) is just one part of the control programme. In order to verify that the data reported by the licensees is representative and legitimate, this programme verifies sampling procedures, accuracy and precision of the data and the changes in the environmental conditions. This paper discusses the main findings of this programme that allowed IRD to optimize its available resources to control the monitoring of the eight facilities in Brazil.

  15. Persistent organic pollutants in biota samples collected during the Ymer-80 expedition to the Arctic

    Directory of Open Access Journals (Sweden)

    Henrik Kylin

    2015-10-01

    Full Text Available During the 1980 expedition to the Arctic with the icebreaker Ymer, a number of vertebrate species were sampled for determination of persistent organic pollutants. Samples of Arctic char (Salvelinus alpinus, n=34, glaucous gull (Larus hyperboreus, n=8, common eider (Somateria mollissima, n=10, Brünnich's guillemot (Uria lomvia, n=9, ringed seal (Pusa hispida, n=2 and polar bear (Ursus maritimus, n=2 were collected. With the exception of Brünnich's guillemot, there was a marked contamination difference of birds from western as compared to eastern/northern Svalbard. Samples in the west contained a larger number of polychlorinated biphenyl (PCB congeners and also polychlorinated terphenyls, indicating local sources. Brünnich's guillemots had similar pollutant concentrations in the west and east/north; possibly younger birds were sampled in the west. In Arctic char, pollutant profiles from lake Linnévatn (n=5, the lake closest to the main economic activities in Svalbard, were similar to profiles in Arctic char from the Shetland Islands (n=5, but differed from lakes to the north and east in Svalbard (n=30. Arctic char samples had higher concentrations of hexachlorocyclohexanes (HCHs than the marine species of birds and mammals, possibly due to accumulation via snowmelt. Compared to the Baltic Sea, comparable species collected in Svalbard had lower concentrations of PCB and dichlorodiphenyltrichloroethane (DDT, but similar concentrations indicating long-range transport of hexachlorobenzene, HCHs and cyclodiene pesticides. In samples collected in Svalbard in 1971, the concentrations of PCB and DDT in Brünnich's guillemot (n=7, glaucous gull (n=2 and polar bear (n=2 were similar to the concentrations found in 1980.

  16. Characterization Data Package for Containerized Sludge Samples Collected from Engineered Container SCS-CON-210

    Energy Technology Data Exchange (ETDEWEB)

    Fountain, Matthew S.; Fiskum, Sandra K.; Baldwin, David L.; Daniel, Richard C.; Bos, Stanley J.; Burns, Carolyn A.; Carlson, Clark D.; Coffey, Deborah S.; Delegard, Calvin H.; Edwards, Matthew K.; Greenwood, Lawrence R.; Neiner, Doinita; Oliver, Brian M.; Pool, Karl N.; Schmidt, Andrew J.; Shimskey, Rick W.; Sinkov, Sergey I.; Snow, Lanee A.; Soderquist, Chuck Z.; Thompson, Christopher J.; Trang-Le, Truc LT; Urie, Michael W.

    2013-09-10

    This data package contains the K Basin sludge characterization results obtained by Pacific Northwest National Laboratory during processing and analysis of four sludge core samples collected from Engineered Container SCS-CON-210 in 2010 as requested by CH2M Hill Plateau Remediation Company. Sample processing requirements, analytes of interest, detection limits, and quality control sample requirements are defined in the KBC-33786, Rev. 2. The core processing scope included reconstitution of a sludge core sample distributed among four to six 4-L polypropylene bottles into a single container. The reconstituted core sample was then mixed and subsampled to support a variety of characterization activities. Additional core sludge subsamples were combined to prepare a container composite. The container composite was fractionated by wet sieving through a 2,000 micron mesh and a 500-micron mesh sieve. Each sieve fraction was sampled to support a suite of analyses. The core composite analysis scope included density determination, radioisotope analysis, and metals analysis, including the Waste Isolation Pilot Plant Hazardous Waste Facility Permit metals (with the exception of mercury). The container composite analysis included most of the core composite analysis scope plus particle size distribution, particle density, rheology, and crystalline phase identification. A summary of the received samples, core sample reconstitution and subsampling activities, container composite preparation and subsampling activities, physical properties, and analytical results are presented. Supporting data and documentation are provided in the appendices. There were no cases of sample or data loss and all of the available samples and data are reported as required by the Quality Assurance Project Plan/Sampling and Analysis Plan.

  17. Activity Concentration for Surface Soil Samples Collected from Arrant, Qena, Egypt

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.; Moustafa, M.

    2010-01-01

    Soil samples were collected from four regions from Armant area. Qena, Upper Egypt for measure their natural radioactivity concentrations due to Ra-226, Th-232 and K-40 radionuclides. Thirty-Four surface soil samples were analyzed by using low-level gamma-spectrometric analysis. The average activity concentration for Ra-226 in (Bq/kg) in the collected soil samples were found to be 27.3 ±3.2, 11.4±1.09, 10.6±1.2, and 11.4±1.02 while the average value for Th-232 were 15.1±1.4, 11.1±0.77, 10.8 ± 0.72 and 11.1 ± 0.8 (Bq/kg) for soil samples from North, South, West and East. The corresponding average values for K-40 were 521.4±16.8, 463±14.8, 488.9±15.6 and 344.5±10.7 (Bq/kg), respectively. Based on radionuclides concentration in surface soil samples the radiological effects can be assessed

  18. Estimation of uranium in drinking water samples collected from different locations across Tarapur, India

    International Nuclear Information System (INIS)

    Dusane, C.B.; Maity, Sukanta; Sahu, S.K.; Pandit, G.G.

    2015-01-01

    In this study, drinking water samples were collected from different locations across Tarapur, India for screening uranium contents. Uranium concentrations were determined by differential pulse adsorptive stripping voltammetry (DPASV). Uranium concentration in water samples varied in a wide range from 0.6-7.9 μg L -1 . Results were compared with the international water quality guidelines World Health Organization (WHO, 2011) and were found within the permissible limit. Results were also compared with the safe limit values for drinking water recommended by national organization like Atomic Energy Regulatory Board (AERB). (author)

  19. Empirical insights and considerations for the OBT inter-laboratory comparison of environmental samples

    International Nuclear Information System (INIS)

    Kim, Sang-Bog; Roche, Jennifer

    2013-01-01

    Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. -- Highlights: ► Inter-laboratory OBT comparisons would provide a good opportunity for developing reference OBT analytical procedures. ► The measurement of environmental OBT concentrations has a higher associated uncertainty. ► Certified reference materials for OBT in environmental samples are required

  20. Surface Sampling Collection and Culture Methods for Escherichia coli in Household Environments with High Fecal Contamination.

    Science.gov (United States)

    Exum, Natalie G; Kosek, Margaret N; Davis, Meghan F; Schwab, Kellogg J

    2017-08-22

    Empiric quantification of environmental fecal contamination is an important step toward understanding the impact that water, sanitation, and hygiene interventions have on reducing enteric infections. There is a need to standardize the methods used for surface sampling in field studies that examine fecal contamination in low-income settings. The dry cloth method presented in this manuscript improves upon the more commonly used swabbing technique that has been shown in the literature to have a low sampling efficiency. The recovery efficiency of a dry electrostatic cloth sampling method was evaluated using Escherichia coli and then applied to household surfaces in Iquitos, Peru, where there is high fecal contamination and enteric infection. Side-by-side measurements were taken from various floor locations within a household at the same time over a three-month period to compare for consistency of quantification of E. coli bacteria. The dry cloth sampling method in the laboratory setting showed 105% (95% Confidence Interval: 98%, 113%) E. coli recovery efficiency off of the cloths. The field application demonstrated strong agreement of side-by-side results (Pearson correlation coefficient for dirt surfaces was 0.83 ( p samples (Pearson (0.53, p method can be utilized in households with high bacterial loads using either continuous (quantitative) or categorical (semi-quantitative) data. The standardization of this low-cost, dry electrostatic cloth sampling method can be used to measure differences between households in intervention and non-intervention arms of randomized trials.

  1. Collection of size fractionated particulate matter sample for neutron activation analysis in Japan

    International Nuclear Information System (INIS)

    Otoshi, Tsunehiko; Nakamatsu, Hiroaki; Oura, Yasuji; Ebihara, Mitsuru

    2004-01-01

    According to the decision of the 2001 Workshop on Utilization of Research Reactor (Neutron Activation Analysis (NAA) Section), size fractionated particulate matter collection for NAA was started from 2002 at two sites in Japan. The two monitoring sites, ''Tokyo'' and ''Sakata'', were classified into ''urban'' and ''rural''. In each site, two size fractions, namely PM 2-10 '' and PM 2 '' particles (aerodynamic particle size between 2 to 10 micrometer and less than 2 micrometer, respectively) were collected every month on polycarbonate membrane filters. Average concentrations of PM 10 (sum of PM 2-10 and PM 2 samples) during the common sampling period of August to November 2002 in each site were 0.031mg/m 3 in Tokyo, and 0.022mg/m 3 in Sakata. (author)

  2. Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-01

    In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Brite TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.

  3. Environmental assessment of wood industrial and collective (with heat network) heating. Synthetic report

    International Nuclear Information System (INIS)

    2005-12-01

    This report proposes a synthesis of the results of an environmental assessment of wood industrial and collective heating. This study is based on a life cycle analysis which quantifies the impacts on the environment of all the related activities: fuel extraction, retailing, final use, and so on. Environmental impacts are assessed by means of different indicators: energetic assessment, greenhouse effect assessment, air pollution (acidification), water pollution (eutrophication), toxic material emissions in air and into the soils. Wood is compared to other heating sources (gas, fuel, electricity). Ways to improve this environmental assessment are discussed with respect to wood supply, boiler auxiliary equipment, boiler and combustion

  4. Urine concentrations of oral salbutamol in samples collected after intense exercise in endurance athletes

    DEFF Research Database (Denmark)

    Hostrup, Morten; Kalsen, Anders; Auchenberg, Michael

    2014-01-01

    Our objective was to investigate urine concentrations of 8 mg oral salbutamol in samples collected after intense exercise in endurance athletes. Nine male endurance athletes with a VO2max of 70.2 ± 5.9 mL/min/kg (mean ± SD) took part in the study. Two hours after administration of 8 mg oral...

  5. Next Generation Offline Approaches to Trace Gas-Phase Organic Compound Speciation: Sample Collection and Analysis

    Science.gov (United States)

    Sheu, R.; Marcotte, A.; Khare, P.; Ditto, J.; Charan, S.; Gentner, D. R.

    2017-12-01

    Intermediate-volatility and semi-volatile organic compounds (I/SVOCs) are major precursors to secondary organic aerosol, and contribute to tropospheric ozone formation. Their wide volatility range, chemical complexity, behavior in analytical systems, and trace concentrations present numerous hurdles to characterization. We present an integrated sampling-to-analysis system for the collection and offline analysis of trace gas-phase organic compounds with the goal of preserving and recovering analytes throughout sample collection, transport, storage, and thermal desorption for accurate analysis. Custom multi-bed adsorbent tubes are used to collect samples for offline analysis by advanced analytical detectors. The analytical instrumentation comprises an automated thermal desorption system that introduces analytes from the adsorbent tubes into a gas chromatograph, which is coupled with an electron ionization mass spectrometer (GC-EIMS) and other detectors. In order to optimize the collection and recovery for a wide range of analyte volatility and functionalization, we evaluated a variety of commercially-available materials, including Res-Sil beads, quartz wool, glass beads, Tenax TA, and silica gel. Key properties for optimization include inertness, versatile chemical capture, minimal affinity for water, and minimal artifacts or degradation byproducts; these properties were assessed with a diverse mix of traditionally-measured and functionalized analytes. Along with a focus on material selection, we provide recommendations spanning the entire sampling-and-analysis process to improve the accuracy of future comprehensive I/SVOC measurements, including oxygenated and other functionalized I/SVOCs. We demonstrate the performance of our system by providing results on speciated VOCs-SVOCs from indoor, outdoor, and chamber studies that establish the utility of our protocols and pave the way for precise laboratory characterization via a mix of detection methods.

  6. Studies on 129I and 14C in environmental samples by AMS

    International Nuclear Information System (INIS)

    Muramatsu, Yasuyuki

    2010-01-01

    We have carried out studies on 129 I and 14 C in environmental samples by AMS (accelerator mass spectrometry). In this paper summary of our results are described. Iodine is an essential element for humans and it pays an important role in thyroid gland. There are more than 30 isotopes of iodine. Among radioiodines 129 I has the longest half-life (1.57x10 7 y). This nuclide is released into the environment from nuclear weapons test, accidents of nuclear facilities (e.g. Chernobyl accident) and operation of spent fuel reprocessing plants. Since soil accumulates iodine, we have focused on the levels of both 129 I and 127 I in surface soils. In our previous studies, we used NAA (neutron activation analysis) for the determination. However, due to the limitation of its analytical sensitivity we could not detect 129 I in samples from background areas. In this study we have analyzed 129 I/ 127 I ratios by AMS and 127 I concentrations by ICP-MS (inductively coupled plasma spectrometry) after separation of iodine from soil by pyrohydrolysis and solvent extraction techniques. Using these methods, we have analyzed samples collected from different areas in Japan. Analytical results for surface soils collected from background areas were in the ranges 1.4 x 10 -5 - 4.6 x 10 -3 Bq/Kg as 129 I concentrations and 3.9 x 10 -11 - 3.0 x 10 -8 as 129 I/ 127 I ratios. The 129 I levels in Tokaimura, where a spent fuel reprocessing plant is located, were one to three orders of magnitude higher than those in background samples. The levels were higher in forest soils than those in field and rice paddy soils due to the interception effect of atmospheric 129 I by tree canopies. A wide range of stable iodine concentrations (0.4-143ppm) was observed. Rice paddy soils contained significantly lower iodine than forest and upland field soils. This should be explained by the desorption of iodine from the rice paddies due to microbial activities during the cultivation. Vertical distributions of 129 I

  7. Phenolic Profiling and Antioxidant Capacity of Eugenia uniflora L. (Pitanga) Samples Collected in Different Uruguayan Locations.

    Science.gov (United States)

    Migues, Ignacio; Baenas, Nieves; Gironés-Vilaplana, Amadeo; Cesio, María Verónica; Heinzen, Horacio; Moreno, Diego A

    2018-04-24

    The use of nutrient-rich foods to enhance the wellness, health and lifestyle habits of consumers is globally encouraged. Native fruits are of great interest as they are grown and consumed locally and take part of the ethnobotanic knowledge of the population. Pitanga is an example of a native fruit from Uruguay, consumed as a jelly or an alcoholic beverage. Pitanga has a red-violet pigmentation, which is a common trait for foods that are a good source of antioxidants. Hence, fruits from different Uruguayan regions were analyzed via miniaturized sample preparation method, HPLC-DAD-ESI/MS n and RP-HPLC-DAD techniques to identify and quantify phenolic compounds, respectively. The antioxidant capacity was evaluated via DPPH and ORAC (Oxygen Radical Absorbance Capacity) assays. A multivariate linear regression was applied to correlate the observed antioxidant capacity with the phenolic content. Furthermore, Principal Components Analysis was performed to highlight characteristics between the various samples studied. The main results indicated differences between northern and southern Uruguayan samples. Delphinidin-3-hexoside was present in southern samples (mean of 293.16 µmol/100 g dry weight (DW)) and absent in the sample collected in the north (sample 3). All the samples contain high levels of cyanidin-3-hexoside, but a noticeable difference was found between the northern sample (150.45 µmol/100 g DW) and the southern sample (1121.98 µmol/100 g DW). The antioxidant capacity (mean ORAC of 56370 µmol Trolox ® /100 g DW) were high in all the samples compared to the Food and Drug Administration (FDA) database of similar berry-fruits. The results of this study highlight the nutraceutical value of a native fruit that has not been exploited until now.

  8. Phenolic Profiling and Antioxidant Capacity of Eugenia uniflora L. (Pitanga Samples Collected in Different Uruguayan Locations

    Directory of Open Access Journals (Sweden)

    Ignacio Migues

    2018-04-01

    Full Text Available The use of nutrient-rich foods to enhance the wellness, health and lifestyle habits of consumers is globally encouraged. Native fruits are of great interest as they are grown and consumed locally and take part of the ethnobotanic knowledge of the population. Pitanga is an example of a native fruit from Uruguay, consumed as a jelly or an alcoholic beverage. Pitanga has a red-violet pigmentation, which is a common trait for foods that are a good source of antioxidants. Hence, fruits from different Uruguayan regions were analyzed via miniaturized sample preparation method, HPLC-DAD-ESI/MSn and RP-HPLC-DAD techniques to identify and quantify phenolic compounds, respectively. The antioxidant capacity was evaluated via DPPH and ORAC (Oxygen Radical Absorbance Capacity assays. A multivariate linear regression was applied to correlate the observed antioxidant capacity with the phenolic content. Furthermore, Principal Components Analysis was performed to highlight characteristics between the various samples studied. The main results indicated differences between northern and southern Uruguayan samples. Delphinidin-3-hexoside was present in southern samples (mean of 293.16 µmol/100 g dry weight (DW and absent in the sample collected in the north (sample 3. All the samples contain high levels of cyanidin-3-hexoside, but a noticeable difference was found between the northern sample (150.45 µmol/100 g DW and the southern sample (1121.98 µmol/100 g DW. The antioxidant capacity (mean ORAC of 56370 µmol Trolox®/100 g DW were high in all the samples compared to the Food and Drug Administration (FDA database of similar berry-fruits. The results of this study highlight the nutraceutical value of a native fruit that has not been exploited until now.

  9. Accuracy and Precision in Elemental Analysis of Environmental Samples using Inductively Coupled Plasma-Atomic Emission Spectrometry

    International Nuclear Information System (INIS)

    Quraishi, Shamsad Begum; Chung, Yong-Sam; Choi, Kwang Soon

    2005-01-01

    Inductively Coupled Plasma-Atomic Emission Spectrometry followed by micro-wave digestion have been performed on different environmental Certified Reference Materials (CRMs). Analytical results show that accuracy and precision in ICP-AES analysis were acceptable and satisfactory in case of soil and hair CRM samples. The relative error of most of the elements in these two CRMs is within 10% with few exceptions and coefficient of variation is also less than 10%. Z-score as an analytical performance was also within the acceptable range (±2). ICP-AES was found as an inadequate method for Air Filter CRM due to incomplete dissolution, low concentration of elements and very low mass of the sample. However, real air filter sample could have been analyzed with high accuracy and precision by increasing sample mass during collection. (author)

  10. A simple passive method of collecting water vapour for environmental tritium monitoring

    International Nuclear Information System (INIS)

    Iida, T.; Fukuda, H.; Ikebe, Y.; Yokoyama, S.

    1995-01-01

    To investigate the average behaviour of tritium in an atmospheric environment, it is necessary to collect water vapour in air over a long period at numerous locations. For the purpose of the study, the passive method was developed: this is handy, low-priced and could collect water vapour in air without motive power. This paper describes the characteristics of the passive collecting method, the performance of water collection in outdoor air and the measurements of tritium concentrations in water samples collected by the passive method. (author)

  11. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  12. Methodology of testing environmental samples from the area surrounding radioactive waste deposits

    International Nuclear Information System (INIS)

    Kropikova, S.; Pastuchova, D.

    1979-01-01

    Methods are described of environmental sample investigation in the area surrounding radioactive waste deposits, namely monitoring ground water, surface water, sediments, water flows and catchments, vegetation and soil. Methods of sample preparation, and methods of radionuclides determination in mixtures are also discussed, as are spot activity measurement methods. (author)

  13. Report for Detection of Biothreat Agents and Environmental Samples using the LLNL Virulence Array for DHS

    Energy Technology Data Exchange (ETDEWEB)

    Jaing, Crystal [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gardner, Shea [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McLoughlin, Kevin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Thissen, James [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jackson, Paul [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2011-04-18

    The objective of this project is to provide DHS a comprehensive evaluation of the current genomic technologies including genotyping, Taqman PCR, multiple locus variable tandem repeat analysis (MLVA), microarray and high-throughput DNA sequencing in the analysis of biothreat agents from complex environmental samples. This report focuses on the design, testing and results of samples on the Virulence Array.

  14. Demonstration and determination of submicroscopic particles of uranium in environmental samples

    International Nuclear Information System (INIS)

    Sihelska, K.; Lorincik, J.; Sus, F.; Vesela, D.

    2016-01-01

    In this work laboratories of the Centrum vyzkumu Rez, Ltd are presented. Fission track analysis (FTA) is used for analysis of uranium in environmental samples. Treatment of samples for FTA is described and some results ar presented. The method of SIMS is used, too.

  15. Rapid Identification of a Cooling Tower-Associated Legionnaires’ Disease Outbreak Supported by Polymerase Chain Reaction Testing of Environmental Samples, New York City, 2014–2015

    Science.gov (United States)

    Benowitz, Isaac; Fitzhenry, Robert; Boyd, Christopher; Dickinson, Michelle; Levy, Michael; Lin, Ying; Nazarian, Elizabeth; Ostrowsky, Belinda; Passaretti, Teresa; Rakeman, Jennifer; Saylors, Amy; Shamoonian, Elena; Smith, Terry-Ann; Balter, Sharon

    2018-01-01

    We investigated an outbreak of eight Legionnaires’ disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings. PMID:29780175

  16. Rapid Identification of a Cooling Tower-Associated Legionnaires' Disease Outbreak Supported by Polymerase Chain Reaction Testing of Environmental Samples, New York City, 2014-2015.

    Science.gov (United States)

    Benowitz, Isaac; Fitzhenry, Robert; Boyd, Christopher; Dickinson, Michelle; Levy, Michael; Lin, Ying; Nazarian, Elizabeth; Ostrowsky, Belinda; Passaretti, Teresa; Rakeman, Jennifer; Saylors, Amy; Shamoonian, Elena; Smith, Terry-Ann; Balter, Sharon

    2018-04-01

    We investigated an outbreak of eight Legionnaires' disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings.

  17. Least-squares resolution of gamma-ray spectra in environmental samples

    International Nuclear Information System (INIS)

    Kanipe, L.G.; Seale, S.K.; Liggett, W.S.

    1977-08-01

    The use of ALPHA-M, a least squares computer program for analyzing NaI (Tl) gamma spectra of environmental samples, is evaluated. Included is a comprehensive set of program instructions, listings, and flowcharts. Two other programs, GEN4 and SIMSPEC, are also described. GEN4 is used to create standard libraries for ALPHA-M, and SIMSPEC is used to simulate spectra for ALPHA-M analysis. Tests to evaluate the standard libraries selected for use in analyzing environmental samples are provided. An evaluation of the results of sample analyses is discussed

  18. Environmental DNA from Seawater Samples Correlate with Trawl Catches of Subarctic, Deepwater Fishes.

    Directory of Open Access Journals (Sweden)

    Philip Francis Thomsen

    Full Text Available Remote polar and deepwater fish faunas are under pressure from ongoing climate change and increasing fishing effort. However, these fish communities are difficult to monitor for logistic and financial reasons. Currently, monitoring of marine fishes largely relies on invasive techniques such as bottom trawling, and on official reporting of global catches, which can be unreliable. Thus, there is need for alternative and non-invasive techniques for qualitative and quantitative oceanic fish surveys. Here we report environmental DNA (eDNA metabarcoding of seawater samples from continental slope depths in Southwest Greenland. We collected seawater samples at depths of 188-918 m and compared seawater eDNA to catch data from trawling. We used Illumina sequencing of PCR products to demonstrate that eDNA reads show equivalence to fishing catch data obtained from trawling. Twenty-six families were found with both trawling and eDNA, while three families were found only with eDNA and two families were found only with trawling. Key commercial fish species for Greenland were the most abundant species in both eDNA reads and biomass catch, and interpolation of eDNA abundances between sampling sites showed good correspondence with catch sizes. Environmental DNA sequence reads from the fish assemblages correlated with biomass and abundance data obtained from trawling. Interestingly, the Greenland shark (Somniosus microcephalus showed high abundance of eDNA reads despite only a single specimen being caught, demonstrating the relevance of the eDNA approach for large species that can probably avoid bottom trawls in most cases. Quantitative detection of marine fish using eDNA remains to be tested further to ascertain whether this technique is able to yield credible results for routine application in fisheries. Nevertheless, our study demonstrates that eDNA reads can be used as a qualitative and quantitative proxy for marine fish assemblages in deepwater oceanic

  19. X RF measurement for sediment sample collected from the niles in Khartoum State

    International Nuclear Information System (INIS)

    Mohammed, Aisha Abdelgader Ahmed

    2015-04-01

    The goal of this study to determine the concentration of element (K, Ca Ti, Mn, Fe, Cu, Zn, Pb, Rb, Sr, Y and Zr) in sediment sample collected from thirty different sites from the three rivers in Khartoum state. X-ray fluorescence (X RF) was used to identify the element concentration. Validation of the equipment was done by measuring reference samples provided by IAEA. Iron was found to be the dominant element with concentration ranged between (13000 ppm) in the white nile to (101000 ppm) in the blue nile, Pb was found to be the lowest among the twelve elements measured with concentration ranged between (11.7 ppm) in the white nile to (28 ppm) in the river nile for all samples. In general there was no variation of the concentration of elements between the blue nile sediments and the river nile sediments and was found variation of concentration of elements between the white nile sediments and other two niles. (Author).

  20. Identification of pink-pigmented bacteria isolated from environmental water samples and their biofilm formation abilities.

    Science.gov (United States)

    Furuhata, Katsunori; Kato, Yuko; Goto, Keiichi; Saitou, Keiko; Sugiyama, Jun-Ichi; Hara, Motonobu; Fukuyama, Masahumi

    2008-06-01

    Sixty-seven strains of pink-pigmented bacteria, which were isolated from environmental water samples collected nationwide, were identified by partial 16S rDNA sequence analysis. In addition, the biofilm formation ability of the isolates was experimentally investigated. We could identify only 2 strains at the species level: Pedobacter roseus HS-38 and Runella slithyformis HS-77. The results showed that of the strains tested, 22 strains (32.8%) were Pedobacter spp., which was most frequently identified, followed by 19 strains (28.4%) of Arcicella spp., 16 strains (23.9%) of Deinococcus spp., 5 strains (7.5%) of Roseomonas spp., 4 strains (6.0%) of Flectobacillus spp. and 1 strain (1.5%) of Runella sp. Most isolates showed low similarity values to previously known species, and they were found to be novel species. At a result, it was difficult to identify environmental water-derived pink-pigmented bacteria at the species level. On the other hand, when we measured the absorbance by the crystal violet staining to examine the quantities of biofilm formation of these strains, fifty-five (82.0%) of the 67 isolates formed biofilm. The absorbance of Deinococcus sp. HS-75 was the highest (3.56). When comparing the absorbance values among the genera, Roseomonas spp. showed the highest absorbance (mean:1.62), followed by Deinococcus spp. (mean: 1.03), and Arcicella spp. (mean: 1.01). Strains of Flectobacillus spp. (mean: 0.48) and Pedobacter spp. (mean: 0.42) showed lower absorbance values. As above, it was shown that, at the species level, the pink-pigmented bacteria in the water in the Japanese environment had various levels of ability to form biofilm.

  1. Feasibility of automated speech sample collection with stuttering children using interactive voice response (IVR) technology.

    Science.gov (United States)

    Vogel, Adam P; Block, Susan; Kefalianos, Elaina; Onslow, Mark; Eadie, Patricia; Barth, Ben; Conway, Laura; Mundt, James C; Reilly, Sheena

    2015-04-01

    To investigate the feasibility of adopting automated interactive voice response (IVR) technology for remotely capturing standardized speech samples from stuttering children. Participants were 10 6-year-old stuttering children. Their parents called a toll-free number from their homes and were prompted to elicit speech from their children using a standard protocol involving conversation, picture description and games. The automated IVR system was implemented using an off-the-shelf telephony software program and delivered by a standard desktop computer. The software infrastructure utilizes voice over internet protocol. Speech samples were automatically recorded during the calls. Video recordings were simultaneously acquired in the home at the time of the call to evaluate the fidelity of the telephone collected samples. Key outcome measures included syllables spoken, percentage of syllables stuttered and an overall rating of stuttering severity using a 10-point scale. Data revealed a high level of relative reliability in terms of intra-class correlation between the video and telephone acquired samples on all outcome measures during the conversation task. Findings were less consistent for speech samples during picture description and games. Results suggest that IVR technology can be used successfully to automate remote capture of child speech samples.

  2. Radiochemical separation of actinides for their determination in environmental samples and waste products

    Energy Technology Data Exchange (ETDEWEB)

    Gleisberg, B [Nuclear Engineering and Analytics Rossendorf, Inc. (VKTA), Dresden (Germany)

    1997-03-01

    The determination of low level activities of actinides in environmental samples and waste products makes high demands on radiochemical separation methods. Artificial and natural actinides were analyzed in samples form the surrounding areas of NPP and of uranium mines, incorporation samples, solutions containing radioactive fuel, solutions and solids resutling from the process, and in wastes. The activities are measured by {alpha}-spectrometry and {gamma}-spectrometry. (DG)

  3. Improvements to sample processing and measurement to enable more widespread environmental application of tritium

    Energy Technology Data Exchange (ETDEWEB)

    Moran, James; Alexander, Thomas; Aalseth, Craig; Back, Henning; Mace, Emily; Overman, Cory; Seifert, Allen; Freeburg, Wilcox

    2017-08-01

    Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120 mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of T behavior in the environment.

  4. Profiling quinones in ambient air samples collected from the Athabasca region (Canada).

    Science.gov (United States)

    Wnorowski, Andrzej; Charland, Jean-Pierre

    2017-12-01

    This paper presents new findings on polycyclic aromatic hydrocarbon oxidation products-quinones that were collected in ambient air samples in the proximity of oil sands exploration. Quinones were characterized for their diurnal concentration variability, phase partitioning, and molecular size distribution. Gas-phase (GP) and particle-phase (PM) ambient air samples were collected separately in the summer; a lower quinone content was observed in the PM samples from continuous 24-h sampling than from combined 12-h sampling (day and night). The daytime/nocturnal samples demonstrated that nighttime conditions led to lower concentrations and some quinones not being detected. The highest quinone levels were associated with wind directions originating from oil sands exploration sites. The statistical correlation with primary pollutants directly emitted from oil sands industrial activities indicated that the bulk of the detected quinones did not originate directly from primary emission sources and that quinone formation paralleled a reduction in primary source NO x levels. This suggests a secondary chemical transformation of primary pollutants as the origin of the determined quinones. Measurements of 19 quinones included five that have not previously been reported in ambient air or in Standard Reference Material 1649a/1649b and seven that have not been previously measured in ambient air in the underivatized form. This is the first paper to report on quinone characterization in secondary organic aerosols originating from oil sands activities, to distinguish chrysenequinone and anthraquinone positional isomers in ambient air, and to report the requirement of daylight conditions for benzo[a]pyrenequinone and naphthacenequinone to be present in ambient air. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  5. Nontuberculous Mycobacteria Isolation from Clinical and Environmental Samples in Iran: Twenty Years of Surveillance

    Directory of Open Access Journals (Sweden)

    Ali Akbar Velayati

    2015-01-01

    Full Text Available Nontuberculous mycobacteria (NTM are opportunistic pathogens that are widely distributed in the environment. There is a lack of data on species distribution of these organisms from Iran. This study consists of a review of NTM articles published in Iran between the years 1992 and 2014. In this review, 20 articles and 14 case reports were identified. Among the 20 articles, 13 (65% studies focused on NTM isolates from clinical specimens, 6 (30% studies examined NTM isolates from environmental samples, and one (5% article included both clinical and environmental isolates. M. fortuitum (229/997; 23% was recorded as the most prevalent and rapid growing mycobacteria (RGM species in both clinical (28% and environmental (19% isolated samples (P < 0.05. Among slow growing mycobacteria (SGM, M. simiae (103/494; 21% demonstrated a higher frequency in clinical samples whereas in environmental samples it was M. flavescens (44/503; 9%. These data represent information from 14 provinces out of 31 provinces of Iran. No information is available in current published data on clinical or environmental NTM from the remaining 17 provinces in Iran. These results emphasize the potential importance of NTM as well as the underestimation of NTM frequency in Iran. NTM is an important clinical problem associated with significant morbidity and mortality in Iran. Continued research is needed from both clinical and environmental sources to help clinicians and researchers better understand and address NTM treatment and prevention.

  6. Nontuberculous Mycobacteria Isolation from Clinical and Environmental Samples in Iran: Twenty Years of Surveillance.

    Science.gov (United States)

    Velayati, Ali Akbar; Farnia, Parissa; Mozafari, Mohadese; Mirsaeidi, Mehdi

    2015-01-01

    Nontuberculous mycobacteria (NTM) are opportunistic pathogens that are widely distributed in the environment. There is a lack of data on species distribution of these organisms from Iran. This study consists of a review of NTM articles published in Iran between the years 1992 and 2014. In this review, 20 articles and 14 case reports were identified. Among the 20 articles, 13 (65%) studies focused on NTM isolates from clinical specimens, 6 (30%) studies examined NTM isolates from environmental samples, and one (5%) article included both clinical and environmental isolates. M. fortuitum (229/997; 23%) was recorded as the most prevalent and rapid growing mycobacteria (RGM) species in both clinical (28%) and environmental (19%) isolated samples (P < 0.05). Among slow growing mycobacteria (SGM), M. simiae (103/494; 21%) demonstrated a higher frequency in clinical samples whereas in environmental samples it was M. flavescens (44/503; 9%). These data represent information from 14 provinces out of 31 provinces of Iran. No information is available in current published data on clinical or environmental NTM from the remaining 17 provinces in Iran. These results emphasize the potential importance of NTM as well as the underestimation of NTM frequency in Iran. NTM is an important clinical problem associated with significant morbidity and mortality in Iran. Continued research is needed from both clinical and environmental sources to help clinicians and researchers better understand and address NTM treatment and prevention.

  7. Series: Practical guidance to qualitative research. Part 3: Sampling, data collection and analysis

    Science.gov (United States)

    Moser, Albine; Korstjens, Irene

    2018-01-01

    Abstract In the course of our supervisory work over the years, we have noticed that qualitative research tends to evoke a lot of questions and worries, so-called frequently asked questions (FAQs). This series of four articles intends to provide novice researchers with practical guidance for conducting high-quality qualitative research in primary care. By ‘novice’ we mean Master’s students and junior researchers, as well as experienced quantitative researchers who are engaging in qualitative research for the first time. This series addresses their questions and provides researchers, readers, reviewers and editors with references to criteria and tools for judging the quality of qualitative research papers. The second article focused on context, research questions and designs, and referred to publications for further reading. This third article addresses FAQs about sampling, data collection and analysis. The data collection plan needs to be broadly defined and open at first, and become flexible during data collection. Sampling strategies should be chosen in such a way that they yield rich information and are consistent with the methodological approach used. Data saturation determines sample size and will be different for each study. The most commonly used data collection methods are participant observation, face-to-face in-depth interviews and focus group discussions. Analyses in ethnographic, phenomenological, grounded theory, and content analysis studies yield different narrative findings: a detailed description of a culture, the essence of the lived experience, a theory, and a descriptive summary, respectively. The fourth and final article will focus on trustworthiness and publishing qualitative research. PMID:29199486

  8. State of the art of environmentally friendly sample preparation approaches for determination of PBDEs and metabolites in environmental and biological samples: A critical review.

    Science.gov (United States)

    Berton, Paula; Lana, Nerina B; Ríos, Juan M; García-Reyes, Juan F; Altamirano, Jorgelina C

    2016-01-28

    Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003-2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Experience with modern technologies at collection, archiving and presentation of environmental data

    International Nuclear Information System (INIS)

    Bartok, J.

    2005-01-01

    This presentation contains solutions in the areas of collection, archiving and presentation of environmental data realised by the company MicroStep-MIS in the Slovakia and abroad. In the first part are characterised in brief used technologies. The second part contains some examples of application of these technologies in complexes monitoring networks

  10. LIIS: A web-based system for culture collections and sample annotation

    Directory of Open Access Journals (Sweden)

    Matthew S Forster

    2014-04-01

    Full Text Available The Lab Information Indexing System (LIIS is a web-driven database application for laboratories looking to store their sample or culture metadata on a central server. The design was driven by a need to replace traditional paper storage with an easier to search format, and extend current spreadsheet storage methods. The system supports the import and export of CSV spreadsheets, and stores general metadata designed to complement the environmental packages provided by the Genomic Standards Consortium. The goals of the LIIS are to simplify the storage and archival processes and to provide an easy to access library of laboratory annotations. The program will find utility in microbial ecology laboratories or any lab that needs to annotate samples/cultures.

  11. The environmental impact of poverty: evidence from firewood collection in rural Nepal.

    Science.gov (United States)

    Baland, Jean-Marie; Bardhan, Pranab; Das, Sanghamitra; Mookherjee, Dilip; Sarkar, Rinki

    2010-01-01

    We investigate determinants of household firewood collection in rural Nepal, using 1995-96 and 2002-3 World Bank Living Standards Measurement Survey (LSMS) data. We incorporate village fixed effects, endogenous censoring, measurement error in living standards and heterogeneous effects of different household assets. We find no evidence in favor of the poverty-environment hypothesis. The evidence for the environmental Kuznets curve depends on the precise measure of living standards and time period studied. Firewood collections fall with a transition to modern occupations and rise with increasing population and household division. The local interhousehold collection externality is negligible, indicating that policy interventions are justified only by ecological considerations or nonlocal spillovers.

  12. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  13. The analysis study of plutonium in the environmental sample by mass spectrum combined with isotopic dilution

    International Nuclear Information System (INIS)

    Han Jun; Fu Zhonghua; Mao Xingen; Meng Fanben

    2004-01-01

    The technology of the rhenium filament carbonization was used to increase the ionization efficiency in this paper. The plutonium in the environmental sample was analyzed by Mass Spectrum combined with isotope dilution. Analysis of the 239 Pu blank in the process: The analysis of 239 Pu from the chemical process was carried out in order to establish the influence of the 239 Pu introduced from the process. The analysis results were shown in Table 1 sample 1 was not gone through the process, sample 2 and sample 3 were gone through the process. It was clear that there was no influence of the 239 Pu from the process within the deviation. Results and Discussions: The environmental samples which were dealed with the chemical method were prepared the sample of mass spectrum, The atomic ratio of the 239 Pu and 242 Pu in the environmental samples was measured by Mass Spectrum. The atomic ratio in the tracer 242 Pu was 0.01476±0.00007.The results for nuclide content in environment were given in Table 2. The content of 239 Pu in the tracer was high, so the existing of 239 Pu in the environmental samples can be determined by the changing of the atomic ratio of 242 Pu to 239 Pu. It was clear that there was 239 Pu in the environmental samples except the cypress leaves-2 and the pine leaves-3 within the deviation, and the content of 239 Pu were given in Table 2. Conclusion: a. Plutonium was separated and purified from the impurity by the anion-exchange and the electrodeposition, it was possible to provide the eligible mass spectrum sample. b. The measurement of plutonium in the environmental samples was not influenced by the flow of the background in the experiment. c. As the technology of the rhenium carbonization was used to increase the ionization efficiency, the content of plutonium which was about 10 -13 g in the environmental sample could be quantitatively analyzed by Mass Spectrum combined with isotope dilution. (authors)

  14. Rapid and stream-lined methods for analysis of actinides in environmental samples

    International Nuclear Information System (INIS)

    Cooper, E.L.

    2001-01-01

    Full text: 1) Project Summary: A systematic study of separating the actinides from each other in 1 M hydrochloric acid media has been carried out using selective oxidation/reduction processes followed by co-precipitation with neodymium fluoride. We have optimized two such procedures, one with bromate and another with permanganate, for the sequential separation of Am, Pu, Np, and U isotopes. The first procedure involves oxidation of Pu, Np and U to +6 state in 1 M HCI media at 85 deg C with 30% NaBrO 3 and separation from trivalent Am by collecting the latter on the first NdF 3 co- precipitated source. Plutonium is then reduced and converted to +4 oxidation state with 40% NaNO 2 at 85 deg C, while Np and U are kept oxidized with additional bromate in solution at 50-70 deg C, thus separating Pu by collection on a second NdF 3 source. At this stage, Np present in the filtrate is reduced with hydroxylamine hydrochloride and separated from U by collecting on a third source. Subsequently, U is reduced with 30% TiCI 3 and co-precipitated on a final source. The second procedure, which employs KMnO 4 in 1 M HCI media at 60-85 deg C for oxidizing Pu, Np and U, and separating from Am, produces MnO 2 which is collected along with Am on the co-precipitated NdF 3 . This MnO 2 is dissolved on the filter itself with 1 ml of acidified 1.5% H 2 O 2 without any degradation of the α-spectra. After evaporating the filtrate to destroy H 2 O 2 , Pu, Np and U are separated by following steps similar to those in the bromate procedure. The recoveries of the actinides with both procedures are >99%. The decontamination factors are between 10 3 and 10 4 . 2) Summary of Proposed Work for the Next Year: Now that the separation procedure has been developed, we will begin to incorporate it into rapid and steam-lined procedures for samples, such as water, air filters and environmental materials. (author)

  15. Insular Biobjective Routing with Environmental Considerations for a Solid Waste Collection System in Southern Chile

    Directory of Open Access Journals (Sweden)

    Daniela S. Arango González

    2017-01-01

    Full Text Available This paper presents a biobjective problem for a solid waste collection system in a set of islands in southern Chile. The first objective minimizes transportation cost and the second one reduces the environmental impact caused by the accumulation of solid waste at the collection points. To solve this problem, biobjective mixed integer linear programming is used. In the model, an itinerary scheme is considered for the visit to the islands. The model decides which collection points are visited per island, the collection pattern, and quantity of solid waste to be collected at each site. The quantity of solid waste is obtained dividing the solid waste generated in the island by the number of collection points selected in that same island and the frequency of visits. For this problem, we considered that the environmental impact function varies through the days during which solid waste is accumulated at each collection point. We present an instance based on real data for a set of islands in Chiloe and Palena regions in southern Chile, in which the deposit node is Dalcahue. We used the epsilon-constraint method and the weighted sum method to obtain the Pareto front, using commercial optimization software.

  16. Environmental and emergency response capabilities of Los Alamos Scientific Laboratory's radiological air sampling program

    International Nuclear Information System (INIS)

    Gunderson, T.C.

    1980-05-01

    Environmental and emergency response radiological air sampling capabilities of the Environmental Surveillance Group at Los Alamos Scientific Laboratory are described. The air sampling program provides a supplementary check on the adequacy of containment and effluent controls, determines compliance with applicable protection guides and standards, and assesses potential environmental impacts on site environs. It also allows evaluation of potential individual and total population doses from airborne radionuclides that may be inhaled or serve as a source of external radiation. The environmental program is sufficient in scope to detect fluctuations and long-term trends in atmospheric levels of radioactivity originating onsite. The emergency response capabilities are designed to respond to both onsite unplanned releases and atmospheric nuclear tests

  17. POLYCYCLIC AROMATIC HYDROCARBON CONTAMINATION LEVELS IN COLLECTED SAMPLES FROM VICINITY OF A HIGHWAY

    Directory of Open Access Journals (Sweden)

    S. V. Samimi ، R. Akbari Rad ، F. Ghanizadeh

    2009-01-01

    Full Text Available Tehran as the biggest city of Iran with a population of more than 10 millions has potentially high pollutant exposures of gas oil and gasoline combustion from vehicles that are commuting in the highways every day. The vehicle exhausts contain polycyclic aromatic hydrocarbons, which are produced by incomplete combustion and can be directly deposited in the environment. In the present study, the presence of polycyclic aromatic hydrocarbons contamination in the collected samples of a western highway in Tehran was investigated. The studied location was a busy highway in Tehran. High performance liquid chromatography equipped with florescence detector was used for determination of polycyclic aromatic hydrocarbons concentrations in the studied samples. Total concentration of the ten studied polycyclic aromatic hydrocarbons compounds ranged from 11107 to 24342 ng/g dry weight in the dust samples and increased from 164 to 2886 ng/g dry weight in the soil samples taken from 300 m and middle of the highway, respectively. Also the average of Σ PAHs was 1759 ng/L in the water samples of pools in parks near the highway. The obtained results indicated that polycyclic aromatic hydrocarbons contamination levels were very high in the vicinity of the highway.

  18. Determination of different contaminants in selective drinking water samples collected from Peshawar valley area

    International Nuclear Information System (INIS)

    Ihsanullah; Khan, M.; Khattak, T.N.; Sattar, A.

    1999-01-01

    Among the pollutants carried through sewage, industrial effluents, fertilizers, pesticides; heavy metals and various pathogenic bacteria are directly related to human/animal diseases. Samples of drinking water were collected from different locations, in the Peshawar area. Cadmium, lead and copper levels in these samples were determined by potentiometric stripping analysis (PSA). The data indicated wide variation in the concentration of these heavy metals. Variation in results is discussed on the basis of some possible sources of contamination. The concentration of cadmium and lead in all the samples was higher compared to the values given in the guideline of World Health Organization (WHO) for drinking water. Copper was below the detection limit in majority of the samples. The values of Cd, Pb and Cu were in the range of 0.023-2.75, 0.025-1.88 and 0-0.67 mg/1 respectively. Various physical quality indices (ph, electrical conductivity and total solids) and pathogenic bacteria (E. coli and total coliforms) were also determined in water samples. Most of the drinking waters was found contaminated with higher levels of Cd and Pb and pathogenic bacteria and hence, considered unfit for drinking purposes. (author)

  19. Composition of Trace Metals in Dust Samples Collected from Selected High Schools in Pretoria, South Africa

    Directory of Open Access Journals (Sweden)

    J. O. Olowoyo

    2016-01-01

    Full Text Available Potential health risks associated with trace metal pollution have necessitated the importance of monitoring their levels in the environment. The present study investigated the concentrations and compositions of trace metals in dust samples collected from classrooms and playing ground from the selected high schools In Pretoria. Schools were selected from Pretoria based on factors such as proximity to high traffic ways, industrial areas, and residential areas. Thirty-two dust samples were collected from inside and outside the classrooms, where learners often stay during recess period. The dust samples were analysed for trace metal concentrations using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS. The composition of the elements showed that the concentrations of Zn were more than all other elements except from one of the schools. There were significant differences in the concentrations of trace metals from the schools (p<0.05. Regular cleaning, proximity to busy road, and well maintained gardens seem to have positive effects on the concentrations of trace metals recorded from the classrooms dust. The result further revealed a positive correlation for elements such as Pb, Cu, Zn, Mn, and Sb, indicating that the dust might have a common source.

  20. CHARACTERISTIC OF AIRBORNE PARTICULATE MATTER SAMPLES COLLECTED FROM TWO SEMI INDUSTRIAL SITES IN BANDUNG, INDONESIA

    Directory of Open Access Journals (Sweden)

    Diah Dwiana Lestiani

    2013-12-01

    Full Text Available Air particulate matter concentrations, black carbon as well as elemental concentrations in two semi industrial sites were investigated as a preliminary study for evaluation of air quality in these areas. Sampling of airborne particulate matter was conducted in July 2009 using a Gent stacked filter unit sampler and a total of 18 pairs of samples were collected. Black carbon was determined by reflectance measurement and elemental analysis was performed using particle induced X-ray emission (PIXE. Elements Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Cu, Zn and As were detected. Twenty four hour PM2.5 concentration at semi industrial sites Kiaracondong and Holis ranged from 4.0 to 22.2 µg m-3, while the PM10 concentration ranged from 24.5 to 77.1 µg m-3. High concentration of crustal elements, sulphur and zinc were identified in fine and coarse fractions for both sites. The fine fraction data from both sites were analyzed using a multivariate principal component analysis and for Kiaracondong site, identified factors are attributed to sea-salt with soil dust, vehicular emissions and biomass burning, non ferrous smelter, and iron/steel work industry, while for Holis site identified factors are attributed to soil dust, industrial emissions, vehicular emissions with biomass burning, and sea-salt. Although particulate samples were collected from semi industrial sites, vehicular emissions constituted with S, Zn and BC were identified in both sites.

  1. The concentration of Cs, Sr and other elements in water samples collected in a paddy field

    International Nuclear Information System (INIS)

    Ban-nai, Tadaaki; Hisamatsu, Shun'ichi; Yanai-Kudo, Masumi; Hasegawa, Hidenao; Torikai, Yuji

    2000-01-01

    To research elemental concentrations in soil water in a paddy field, samples of the soil water were collected with porous Teflon resin tubes which were buried in the field. The soil water collections were made at various depth, 2.5, 12.5, 25 and 35 cm from the surface in the paddy field, located in Rokkasho, Aomori, once every two weeks during the rice cultivation period, from May to October in 1998. The paddy field was irrigated from May 7th to July 20th, dried from July 20th to August 5th, then again irrigated until September 16th. Drastic changes of the alkaline earth metal elements, Fe and Mn in soil water samples were seen at the beginning and end of the midsummer drainage. The concentrations of Cs, Fe, Mn and NH 4 in soil water samples showed a similar variation pattern to that of alkaline earth metal elements in the waterlogged period. The change of redox potential was considered a possible cause for the concentration variation for these substances. (author)

  2. Preparation of in-house calibration source for the use in radioactivity analysis of the environmental samples. Consideration of homogeneity

    International Nuclear Information System (INIS)

    Aba, A.; Ismaeel, A.

    2013-01-01

    An in-house reference material has been prepared in Kuwait Institute for Scientific Research radioecology laboratory, for quality control purposes of gamma spectrometer systems. The material contains a known amount of uranium ore reference material (prepared by the International Atomic Energy Agency and coded as IAEA-RGU-1) which is mixed with marine sediment collected from Kuwait bay. The IAEA-RGU-1 has been certified that it is in equilibrium state with the decay daughters, and stable to be used for quality control purposes. Nevertheless, the homogeneous distribution of the doped material with the prepared source should be verified. This has been examined using gamma spectrometry measurements in conjunction with analysis of variance statistical tools, Dixon, box plots and Grubbs tests. The calculated total uncertainty has been utilized to establish the recommended specific activity ranges of 226 Ra, 224 Th, 214 Pb, 214 Bi and 210 Pb radioisotopes in the prepared source. The obtained results showed that the estimated uncertainty arising from the sample inhomogeneity has a significant contribution in the total uncertainty. The stability control charts of the ultra-low background gamma spectrometry system demonstrated the suitability of the prepared material for the purpose of quality control. However, the emitted gamma-rays from the prepared source covers the required energy range for determination of natural and artificial radionuclides in different species of environmental samples such as marine sediment, soil samples, and samples contaminated by naturally occurring radioactive material produced by oil industry. In addition, the material might be used for system calibration in case its traceability is proven. The experimental data revealed the significance of the homogeneity in preparing environmental samples for radioactivity measurements; in particular when small sample quantities of environmental samples are required to be analyzed. (author)

  3. Wet-digestion of environmental sample using silver-mediated electrochemical method

    International Nuclear Information System (INIS)

    Kuwabara, Jun

    2010-01-01

    An application of silver-mediated electrochemical method to environmental samples as the effective digestion method for iodine analysis was tried. Usual digestion method for 129 I in many type of environmental sample is combustion method using quartz glass tube. Chemical yield of iodine on the combustion method reduce depending on the type of sample. The silver-mediated electrochemical method is expected to achieve very low loss of iodine. In this study, dried kombu (Laminaria) sample was tried to digest with electrochemical cell. At the case of 1g of sample, digestion was completed for about 24 hours under the electric condition of <10V and <2A. After the digestion, oxidized species of iodine was reduced to iodide by adding sodium sulfite. And then the precipitate of silver iodide was obtained. (author)

  4. Study on auto-plating process time versus recovery for polonium, Po-210 in environmental sample

    International Nuclear Information System (INIS)

    Jalal Sharib; Zaharudin Ahmad; Abdul Kadir Ishak; Norfaizal Mohamed; Ahmad Sanadi Abu Bakar; Yii Mei Wo; Kamarozaman Ishak; Siti Aminah Yusoff

    2008-08-01

    This study was carried out to evaluate time effectiveness and recovery 16 samples of 4 Kuala Muda stations during auto-plating process procedures for determination Polonium, Po 210 activity concentration in environmental sample. The study was performed using Kuala Muda sediment as sample in the same methodology. The auto-plating process runs for 4, 12, 24 and 30 hours on a silver disc for 4 samples each station, and then counted for one (1) day using an alpha spectrometry counting system. The objectives for this study is to justify on time duration for auto-plating process effecting a chemical yield of Po-209.The results showed recovery are increasing versus time and constantly at 24 hour auto-plating. Its mean, 24 hour is an optimum time for auto-plating process for determination of Polonium, Po 210 activity concentration in environmental sample. (Author)

  5. Evaluation of oxidation techniques for preparing bioassay and environmental samples for liquid scintillation counting

    International Nuclear Information System (INIS)

    Miller, H.H.

    1979-10-01

    In environmental and biological monitoring for carbon-14 and tritium, the presence of color and chemical quenching agents in the samples can degrade the efficiency of liquid scintillation counting. A series of experiments was performed to evaluate the usefulness, under routine conditions, of first oxidizing the samples to improve the counting by removing the color and quenching agents. The scintillation counter was calibrated for the effects of quenching agents on its counting efficiency. Oxidizing apparatus was tested for its ability to accurately recover the 14 C and 3 H in the samples. Scintillation counting efficiences were compared for a variety of oxidized and unoxidized environmental and bioassay samples. The overall conclusion was that, for routine counting, oxidation of such samples is advantageous when they are highly quenched or in solid form

  6. Tritium analysis in environmental samples around Nuclear Power Plants and nationwide surveillance of radionuclides in some environmental samples(meat and drinking water)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2001-12-15

    12 kind of environmental samples such as soil, underground water, seawater, etc. around the Nuclear Power Plants(NPP) and surface seawater around the Korea peninsula were sampled, For the samples of rain, pine-needle, air, seawater, underground water, chinese cabbage, grain of rice and milk sampled around NPP, and surface seawater and rain sampled all around country, tritium concentration was measured, The tritium concentration in the tap water and the gamma activity in the domestic and imported beef that were sampled at ward in the large city in Korea(Seoul, Pusan, Taegu, Taejun, Inchun, Kwangju) were analyzed for the meat and drinking waters. As the results of analyzing, tritium concentration in rain and tap water were very low all around country, but a little higher around the NPP than general surrounding. At the Wolsung NPP, tritium concentration was descend according to distance from the stack. Tritium activity of surface seawater around the Korea peninsula was also, very low. The measured radioactive elements in the beef is the same as the radioactive elements on the earth surface.

  7. INTERIM REPORT, DEVELOP A SAMPLING STRATEGY: PREPARE TO IMPLEMENT A COHORT STUDY OF CHILDREN'S ENVIRONMENTAL HEALTH

    Science.gov (United States)

    OverviewThe goal of the National Children's Study (NCS) is to collect information on environmental andsocial factors in the lives of children, starting before birth and continuing until age 21, to informresearchers about their effects on the health and dev...

  8. Rapid and Automated Determination of Plutonium and Neptunium in Environmental Samples

    DEFF Research Database (Denmark)

    Qiao, Jixin

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development...... and optimization for rapid determination of plutonium in environmental samples using SIextraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples...... for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including...

  9. Determination of 237Np in environmental and nuclear samples: A review of the analytical method

    International Nuclear Information System (INIS)

    Thakur, P.; Mulholland, G.P.

    2012-01-01

    A number of analytical methods has been developed and used for the determination of neptunium in environmental and nuclear fuel samples using alpha, ICP–MS spectrometry, and other analytical techniques. This review summarizes and discusses development of the radiochemical procedures for separation of neptunium (Np), since the beginning of the nuclear industry, followed by a more detailed discussion on recent trends in the separation of neptunium. This article also highlights the progress in analytical methods and issues associated with the determination of neptunium in environmental samples. - Highlights: ► Determination of Np in environmental and nuclear samples is reviewed. ► Various analytical methods used for the determination of Np are listed. ► Progress and issues associated with the determination of Np are discussed.

  10. Rapid and automated determination of plutonium and neptunium in environmental samples

    International Nuclear Information System (INIS)

    Qiao, J.

    2011-03-01

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242 Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  11. Rapid and automated determination of plutonium and neptunium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Qiao, J.

    2011-03-15

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  12. Procedures for the collection and preservation of groundwater and surface water samples and for the installation of monitoring wells

    International Nuclear Information System (INIS)

    Korte, N.; Kearl, P.

    1984-01-01

    Proper sampling procedures are essential for a successful water-quality monitoring program. It must be emphasized, however, that it is impossible to maintain absolutely in-situ conditions when collecting and preserving a water sample, whether from a flowing stream or an aquifer. Consequently, the most that can reasonably be expected is to collect a best possible sample with minimal disturbance. This document describes procedures for installing monitoring wells and for collecting samples of surface water and groundwater. The discussion of monitoring wells includes mention of multilevel sampling and a general overview of vadose-zone monitoring. Guidelines for well installation are presented in detail. The discussion of water-sample collection contains evaluations of sampling pumps, filtration equipment, and sample containers. Sample-preservation techniques, as published by several government and private sources, are reviewed. Finally, step-by-step procedures for collection of water samples are provided; these procedures address such considerations as necessary equipment, field operations, and written documentation. Separate procedures are also included for the collection of samples for determination of sulfide and for reactive aluminum. The report concludes with a brief discussion of adverse sampling, conditions that may significantly affect the quality of the data. Appendix A presents a rationale for the development and use of statistical considerations in water sampling to ensure a more complete water quality monitoring program. 51 references, 9 figures, 4 tables

  13. DNA typing of ancient parasite eggs from environmental samples identifies human and animal worm infections in viking-age settlement

    DEFF Research Database (Denmark)

    Søe, Martin Jensen; Nejsum, Peter; Fredensborg, Brian Lund

    2015-01-01

    Ancient parasite eggs were recovered from environmental samples collected at a Viking-age settlement in Viborg, Denmark, dated 1018-1030 A.D. Morphological examination identified Ascaris sp., Trichuris sp., and Fasciola sp. eggs, but size and shape did not allow species identification. By carefully...... selecting genetic markers, PCR amplification and sequencing of ancient DNA (aDNA) isolates resulted in identification of: the human whipworm, Trichuris trichiura, using SSUrRNA sequence homology; Ascaris sp. with 100% homology to cox1 haplotype 07; and Fasciola hepatica using ITS1 sequence homology...

  14. Proton Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrometry (AAS) applied in the environmental sample analysis

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Iordan, M.; Stihi, C.; Bancuta, A.; Dima, G.; Busuioc, G.; Ciupina, V.; Belc, M.; Badica, T.

    2003-01-01

    The aim of this work is to determine the elemental composition of tree leaves using Proton-Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrophotometry (AAS) methods. By PIXE Spectrometry we identified and determined the concentration of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu Zn, As, Br, Sr and by AAS method the concentration of elements: Cr, Mn, Fe, Co, Cu, Zn, Se, Cd. Pb was identified in only 2 samples from 29. For tree leave samples collected at a large distance to the polluting source the Sr concentration decreased and the Mg, Ca, Se, Zn and Fe concentrations increased. Also, we can observe a small affinity of these leaves for the environmental Pb which was detected for two samples at a small distance to polluting source. (authors)

  15. Determination of uranium from nuclear fuel in environmental samples using inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F. [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen]|[Radiation Physics and Chemistry Problems Inst., Minsk (Belarus); Becker, J.S. [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen

    2000-11-01

    As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The {sup 236}U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on inductively coupled plasma quadrupole mass spectrometry with a hexapole collision cell (HEX-ICP-QMS). The figures of merit of the HEX-ICP-QMS were studied with a plasma-shielded torch using different nebulizers (such as an ultrasonic nebulizer (USN) and Meinhard nebulizer) for solution introduction. A {sup 238}U{sup +} ion intensity of up to 27000 MHz/ppm in HEX-ICP-QMS with USN was observed by introducing helium into the hexapole collision cell as the collision gas at a flow rate of 10 ml min{sup -1}. The formation rate of uranium hydride ions UH{sup +}/U{sup +} of 2 x 10{sup -6} was obtained by using USN with a membrane desolvator. The limit of {sup 236}U/{sup 238}U ratio determination in 10 {mu}g 1{sup -1} uranium solution was 3 x 10{sup -7} corresponding to the detection limit for {sup 236}U of 3 pg 1{sup -1}. The precision of uranium isotopic ratio measurements in 10 {mu}g 1{sup -1} laboratory uranium isotopic standard solution was 0.13% ({sup 235}U/{sup 238}U) and 0.33% ({sup 236}U/{sup 238}U) using a Meinhard nebulizer and 0.45% ({sup 235}U/{sup 238}U) and 0.88% ({sup 236}U/{sup 238}U) using a USN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the {sup 236}U/{sup 238}U ratio ranged from 10{sup -5} to 10{sup -3}. (orig.)

  16. Analysis of Dust Samples Collected from an Unused Spent Nuclear Fuel Interim Storage Container at Hope Creek, Delaware.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Enos, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    In July, 2014, the Electric Power Research Institute and industry partners sampled dust on the surface of an unused canister that had been stored in an overpack at the Hope Creek Nuclear Generating Station for approximately one year. The foreign material exclusion (FME) cover that had been on the top of the canister during storage, and a second recently - removed FME cover, were also sampled. This report summarizes the results of analyses of dust samples collected from the unused Hope Creek canister and the FME covers. Both wet and dry samples of the dust/salts were collected, using SaltSmart(TM) sensors and Scotch - Brite(TM) abrasive pads, respectively. The SaltSmart(TM) samples were leached and the leachate analyzed chemically to determine the composition and surface load per unit area of soluble salts present on the canister surface. The dry pad samples were analyzed by X-ray fluorescence and by scanning electron microscopy to determine dust texture and mineralogy; and by leaching and chemical analysis to deter mine soluble salt compositions. The analyses showed that the dominant particles on the canister surface were stainless steel particles, generated during manufacturing of the canister. Sparse environmentally - derived silicates and aluminosilicates were also present. Salt phases were sparse, and consisted of mostly of sulfates with rare nitrates and chlorides. On the FME covers, the dusts were mostly silicates/aluminosilicates; the soluble salts were consistent with those on the canister surface, and were dominantly sulfates. It should be noted that the FME covers were w ashed by rain prior to sampling, which had an unknown effect of the measured salt loads and compositions. Sulfate salts dominated the assemblages on the canister and FME surfaces, and in cluded Ca - SO4 , but also Na - SO4 , K - SO4 , and Na - Al - SO4 . It is likely that these salts were formed by particle - gas conversion reactions, either

  17. Waste collection systems for recyclables: An environmental and economic assessment for the municipality of Aarhus (Denmark)

    International Nuclear Information System (INIS)

    Larsen, A.W.; Merrild, H.; Moller, J.; Christensen, T.H.

    2010-01-01

    Recycling of paper and glass from household waste is an integrated part of waste management in Denmark, however, increased recycling is a legislative target. The questions are: how much more can the recycling rate be increased through improvements of collection schemes when organisational and technical limitations are respected, and what will the environmental and economic consequences be? This was investigated in a case study of a municipal waste management system. Five scenarios with alternative collection systems for recyclables (paper, glass, metal and plastic packaging) were assessed by means of a life cycle assessment and an assessment of the municipality's costs. Kerbside collection would provide the highest recycling rate, 31% compared to 25% in the baseline scenario, but bring schemes with drop-off containers would also be a reasonable solution. Collection of recyclables at recycling centres was not recommendable because the recycling rate would decrease to 20%. In general, the results showed that enhancing recycling and avoiding incineration was recommendable because the environmental performance was improved in several impact categories. The municipal costs for collection and treatment of waste were reduced with increasing recycling, mainly because the high cost for incineration was avoided. However, solutions for mitigation of air pollution caused by increased collection and transport should be sought.

  18. Microbial Indicator Profiling of Fresh Produce and Environmental Samples from Farms and Packing Facilities in Northern Mexico.

    Science.gov (United States)

    Heredia, Norma; Caballero, Cindy; Cárdenas, Carmen; Molina, Karina; García, Rafael; Solís, Luisa; Burrowes, Vanessa; Bartz, Faith E; de Aceituno, Anna Fabiszewski; Jaykus, Lee-Ann; García, Santos; Leon, Juan

    2016-07-01

    To compare microbiological indicator and pathogen contamination among different types of fresh produce and environmental samples along the production chain, 636 samples of produce (rinsates from cantaloupe melons, jalapeño peppers, and tomatoes) and environmental samples (rinsates from hands of workers, soil, and water) were collected at four successive steps in the production process (from the field before harvest through the packing facility) on 11 farms in northern Mexico during 2011 and 2012. Samples were assayed for enteric pathogens (Escherichia coli O157:H7, other Shiga toxigenic E. coli, Salmonella, and Listeria monocytogenes) and microbial indicators (coliforms, other E. coli strains, and Enterococcus spp.). Salmonella was the only pathogen detected; it was found in one preharvest jalapeño sample (detection limits: 0.0033 CFU/ml in produce and hand samples, 0.0013 CFU/ml in water, and 0.04 CFU/g in soil). Microbial indicator profiles for produce, worker hands, and soil from jalapeño and tomato farms were similar, but cantaloupe farm samples had higher indicator levels (P soil (indicators were significantly more prevalent (70 to 89% of samples were positive; P = 0.01 to 0.02), and geometric mean levels were higher (0.3 to 0.6 log CFU/100 ml) than those in cantaloupe farm water (32 to 38% of samples were positive, geometric mean indicators were present during all production steps, but prevalence and levels were generally highest at the final on-farm production step (the packing facility) (P type and production step can inform the design of effective approaches to mitigate microbial contamination.

  19. Effects of the number of people on efficient capture and sample collection: A lion case study

    Directory of Open Access Journals (Sweden)

    Sam M. Ferreira

    2013-05-01

    Full Text Available Certain carnivore research projects and approaches depend on successful capture of individuals of interest. The number of people present at a capture site may determine success of a capture. In this study 36 lion capture cases in the Kruger National Park were used to evaluate whether the number of people present at a capture site influenced lion response rates and whether the number of people at a sampling site influenced the time it took to process the collected samples. The analyses suggest that when nine or fewer people were present, lions appeared faster at a call-up locality compared with when there were more than nine people. The number of people, however, did not influence the time it took to process the lions. It is proposed that efficient lion capturing should spatially separate capture and processing sites and minimise the number of people at a capture site.

  20. Effects of the number of people on efficient capture and sample collection: a lion case study.

    Science.gov (United States)

    Ferreira, Sam M; Maruping, Nkabeng T; Schoultz, Darius; Smit, Travis R

    2013-05-24

    Certain carnivore research projects and approaches depend on successful capture of individuals of interest. The number of people present at a capture site may determine success of a capture. In this study 36 lion capture cases in the Kruger National Park were used to evaluate whether the number of people present at a capture site influenced lion response rates and whether the number of people at a sampling site influenced the time it took to process the collected samples. The analyses suggest that when nine or fewer people were present, lions appeared faster at a call-up locality compared with when there were more than nine people. The number of people, however, did not influence the time it took to process the lions. It is proposed that efficient lion capturing should spatially separate capture and processing sites and minimise the number of people at a capture site.

  1. Ram-air sample collection device for a chemical warfare agent sensor

    Science.gov (United States)

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  2. Some analytical aspects about determination of Sr89 and Sr90 in environmental samples

    International Nuclear Information System (INIS)

    Gasco, C.; Alvarez Garcia, A.

    1988-01-01

    Some problems about determination of Sr 89 and Sr 90 in environmental samples have been studied. The main difficulties are due to the wide range in the concentration of their components and the contents of chemical and radiochemical interferent elements. The behaviour of strontium on ion exchange resin has been described by some experiments in various media: aqueous media, calcium concentration and matrix variable. The differences of alkaline-earth nitrate and carbonate solubilities have been analyzed in nitric acid. The chemical recovery in environmental samples has been determined. (Author)

  3. Helium-3 mass spectrometry for low-level tritium analysis of environmental samples

    International Nuclear Information System (INIS)

    Surano, K.A.; Hudson, G.B.; Failor, R.A.; Sims, J.M.; Holland, R.C.; MacLean, S.C.; Garrison, J.C.

    1991-04-01

    Helium-3 ( 3 He) mass spectrometry for the analysis of low-level tritium ( 3 H) concentrations in environmental sample matrices was compared with conventional low-level β-decay counting methods. The mass-spectrometry method compared favorably, equaling or surpassing conventional decay-counting methods with respect to most criteria. Additional research and method refinements may make 3 He mass spectrometry the method of choice for routine, low-level to very-low-level 3 H measurements in a wide variety of environmental samples in the future

  4. Molecular dynamics based enhanced sampling of collective variables with very large time steps

    Science.gov (United States)

    Chen, Pei-Yang; Tuckerman, Mark E.

    2018-01-01

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  5. Determination of 90Sr in environmental samples by microwave assisted digestion - chromatographic separation

    International Nuclear Information System (INIS)

    Torres, J.M.; Llaurado, M.; Rauret, G.

    1998-01-01

    The stages involved in the determination of 90 Sr in environmental samples are: sample attack, radiochemical separation (of both 90 Sr and its progeny 90 Y) and measurement. For the determination of 90 Sr, the introduction of microwave-assisted digestion methods has improved acid attack by drastically decreasing both digestion time and the volume of acidic reagents. Recent studies describe many applications of microwave-assisted methods for the determination of inorganic and organometallic compounds in several matrices. We have recently studied the microwave-assisted digestion of soils for the 90 Sr determination. The presented work extends the application of microwaves for the 90 Sr determination to other environmental samples such as sediments, vegetation and milk. An open-focused microwave system, which accepts large samples intakes usually required for radioanalytical chemistry due to the low level content of radionuclides in environmental samples, was used. This system can handle up to 10 g of sample intake which, in many cases, is enough to have acceptable limits of detection. Different digestion procedures are optimised for each matrix studied, paying special attention to the microwave power, the time of digestion and the volume of acidic reagents. Once the sample is in solution a new separation procedure using a specific resin -Sr.Spec- is applied and the measurement is performed by liquid scintillation. The results obtained are compared with a previously optimised method based on liquid-liquid extraction of 90 Y and Cerenkov radiation measurement

  6. Study of Efficiency Calibrations of HPGe Detectors for Radioactivity Measurements of Environmental Samples

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.

    2009-01-01

    In this paper, we describe a method of calibrating of efficiency of a HPGe gamma-ray spectrometry of bulk environmental samples (Tea, crops, water, and soil) is a significant part of the environmental radioactivity measurements. Here we will discuss the full energy peak efficiency (FEPE) of three HPGe detectors it as a consequence, it is essential that the efficiency is determined for each set-up employed. Besides to take full advantage at gamma-ray spectrometry, a set of efficiency at several energies which covers the wide the range in energy, the large the number of radionuclides whose concentration can be determined to measure the main natural gamma-ray emitters, the efficiency should be known at least from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y). Radioactive sources were prepared from two different standards, a first mixed standard QC Y 40 containing 210 Pb, 241 Am, 109 Cd, and Co 57 , and the second QC Y 48 containing 241 Am, 109 Cd, 57 Co, 139 Ce, 113 Sn, 85 Sr, 137 Cs, 88 Y, and 60 Co is necessary in order to calculate the activity of the different radionuclides contained in a sample. In this work, we will study the efficiency calibration as a function of different parameters as:- Energy of gamma ray from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y), three different detectors A, B, and C, geometry of containers (point source, marinelli beaker, and cylindrical bottle 1 L), height of standard soil samples in bottle 250 ml, and density of standard environmental samples. These standard environmental sample must be measured before added standard solution because we will use the same environmental samples in order to consider the self absorption especially and composition in the case of volume samples.

  7. Objective sampling design in a highly heterogeneous landscape - characterizing environmental determinants of malaria vector distribution in French Guiana, in the Amazonian region.

    Science.gov (United States)

    Roux, Emmanuel; Gaborit, Pascal; Romaña, Christine A; Girod, Romain; Dessay, Nadine; Dusfour, Isabelle

    2013-12-01

    Sampling design is a key issue when establishing species inventories and characterizing habitats within highly heterogeneous landscapes. Sampling efforts in such environments may be constrained and many field studies only rely on subjective and/or qualitative approaches to design collection strategy. The region of Cacao, in French Guiana, provides an excellent study site to understand the presence and abundance of Anopheles mosquitoes, their species dynamics and the transmission risk of malaria across various environments. We propose an objective methodology to define a stratified sampling design. Following thorough environmental characterization, a factorial analysis of mixed groups allows the data to be reduced and non-collinear principal components to be identified while balancing the influences of the different environmental factors. Such components defined new variables which could then be used in a robust k-means clustering procedure. Then, we identified five clusters that corresponded to our sampling strata and selected sampling sites in each stratum. We validated our method by comparing the species overlap of entomological collections from selected sites and the environmental similarities of the same sites. The Morisita index was significantly correlated (Pearson linear correlation) with environmental similarity based on i) the balanced environmental variable groups considered jointly (p = 0.001) and ii) land cover/use (p-value sampling approach. Land cover/use maps (based on high spatial resolution satellite images) were shown to be particularly useful when studying the presence, density and diversity of Anopheles mosquitoes at local scales and in very heterogeneous landscapes.

  8. Multi-element analyses of Vietnamese environmental samples for radiation protection

    International Nuclear Information System (INIS)

    Mai, T.H.; Nguyen, T.B.; Nguyen, T.N.; Yoshida, S.

    2005-01-01

    The Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) were used for measuring 8 major and 27 trace elements in food and soil samples collected in Vietnam. The concentration of elements in food samples was different from different locations and also from different food groups. Depth profiles of the elements were discussed for soil samples. (author)

  9. Surface water sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    This Sampling and Analysis Plan addresses surface water monitoring, sampling, and analysis activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Surface water monitoring will be conducted at nine sites within WAG 6. Activities to be conducted will include the installation, inspection, and maintenance of automatic flow-monitoring and sampling equipment and manual collection of various water and sediment samples. The samples will be analyzed for various organic, inorganic, and radiological parameters. The information derived from the surface water monitoring, sampling, and analysis will aid in evaluating risk associated with contaminants migrating off-WAG, and will be used in calculations to establish relationships between contaminant concentration (C) and flow (Q). The C-Q relationship will be used in calculating the cumulative risk associated with the off-WAG migration of contaminants.

  10. Surface water sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    International Nuclear Information System (INIS)

    1994-06-01

    This Sampling and Analysis Plan addresses surface water monitoring, sampling, and analysis activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Surface water monitoring will be conducted at nine sites within WAG 6. Activities to be conducted will include the installation, inspection, and maintenance of automatic flow-monitoring and sampling equipment and manual collection of various water and sediment samples. The samples will be analyzed for various organic, inorganic, and radiological parameters. The information derived from the surface water monitoring, sampling, and analysis will aid in evaluating risk associated with contaminants migrating off-WAG, and will be used in calculations to establish relationships between contaminant concentration (C) and flow (Q). The C-Q relationship will be used in calculating the cumulative risk associated with the off-WAG migration of contaminants

  11. Anger and retribution after collective overuse: the role of blaming and environmental uncertainty in social dilemmas.

    Science.gov (United States)

    de Kwaadsteniet, Erik W; van Dijk, Eric; Wit, Arjaan; De Cremer, David

    2010-01-01

    This article investigates how group members respond to one another when collective overuse occurs. The authors argue that interpersonal reactions after overuse in a common-resource dilemma are largely determined by the environmental characteristics of the social dilemma. More specifically, under environmental certainty they expect people to show more anger to group members than under uncertainty (Study 1). Additionally, they expect stronger retributive reactions to high harvesters than to moderate harvesters, and they expect this difference to be larger under certainty than under uncertainty (Study 2 and 3). Moreover, they predict that these effects are mediated by blaming. The results of three experiments corroborate these predictions.

  12. Determination of short-lived trace elements in environmental samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Wardani, S.; Sihombing, E.; Hamzah, A.; Rochidi; Hery, P.S.; Hartaman, S.; Iman, J.

    1998-01-01

    Concentration of a short-lived trace elements in environmental samples were determined by neutron activation analysis, a counting loss often occur due to the high counting rate. A Pile-Up Rejecter (PUR) electric circuit was installed in counting a short-lived trace elements by a γ-ray spectrometer in order to correct a counting loss. The samples were irradiated for 30∼60 seconds at neutron flux of 3.5 x 10 12 n.cm -2 .s -1 , then the samples cooled for 120 second and counted for 180 second using this system. The nuclides concentration in the varieties environmental samples have a difference analysis result, was more accurate and precise, which the measured result would be 30 % more higher by PUR system than the result would be counted using a conventional γ-ray spectrometry method

  13. A semi-empirical approach to calculate gamma activities in environmental samples

    International Nuclear Information System (INIS)

    Palacios, D.; Barros, H.; Alfonso, J.; Perez, K.; Trujillo, M.; Losada, M.

    2006-01-01

    We propose a semi-empirical method to calculate radionuclide concentrations in environmental samples without the use of reference material and avoiding the typical complexity of Monte-Carlo codes. The calculation of total efficiencies was carried out from a relative efficiency curve (obtained from the gamma spectra data), and the geometric (simulated by Monte-Carlo), absorption, sample and intrinsic efficiencies at energies between 130 and 3000 keV. The absorption and sample efficiencies were determined from the mass absorption coefficients, obtained by the web program XCOM. Deviations between computed results and measured efficiencies for the RGTh-1 reference material are mostly within 10%. Radionuclide activities in marine sediment samples calculated by the proposed method and by the experimental relative method were in satisfactory agreement. The developed method can be used for routine environmental monitoring when efficiency uncertainties of 10% can be sufficient.(Author)

  14. Potential Use of Passive Sampling for Environmental Monitoring of Petroleum E&P Operations

    Science.gov (United States)

    Traditional environmental monitoring relies on water or soil samples being taken at various time increments and sent to offsite laboratories for analysis. Reliance on grab samples generally captures limited “snapshots” of environmental contaminant concentrations, is time intensive, costly, and generates residual waste from excess sample and/or reagents used in the analysis procedures. As an alternative, we are evaluating swellable organosilica sorbents to create passive sampling systems for monitoring applications. Previous work has focused on absorption and detection of fuels, chlorinated solvents, endocrine disruptors, explosives, pesticides, fluorinated chemicals, and metals including Ba, Sr, Hg, Pb, Fe, Cu, and Zn. The advantages of swellable organosilica are that the material cancapture target compounds for an extended periods of time, does not absorb natural organic matter, and resists biofilm formation since the sorbent possesses an animated surface morphology.

  15. An improved combustion apparatus for the determination of organically bound tritium in environmental samples

    International Nuclear Information System (INIS)

    Du, Lin; Shan, Jian; Ma, Yu-Hua; Wang, Ling; Qin, Lai-Lai; Pi, Li; Zeng, You-Shi; Xia, Zheng-Hai; Wang, Guang-Hua; Liu, Wei

    2016-01-01

    This paper reports an improved combustion apparatus for the determination of organically bound tritium in environmental samples. The performance of this apparatus including the recovery rate and reproducibility was investigated by combusting lettuce and pork samples. To determine the factors for the different recovery rates of lettuce and pork and investigate whether the samples were completely oxidized, the ashes and exhaust gases produced by the combustion were analyzed. The results indicate that the apparatus showed an excellent performance in the combustion of environmental samples. Thus, the improvements conducted in this study were effective. - Highlights: • Three major improvements were made to develop the combustion apparatus for OBT. • The recovery is higher and more stable than that of current equipment. • Little hydrogen was present in the ashes and exhaust after combustion.

  16. PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.

  17. The determination of arsenic, selenium, antimony, and tin in complex environmental samples by hydride generation AAS

    International Nuclear Information System (INIS)

    Johnson, D.; Beach, C.

    1990-01-01

    Hydride generation techniques are used routinely for the determination of As, Se, Sb and Sn in water samples. Advantages include high sensitivity, simplicity, and relative freedom from interferences. Continuous-flow designs greatly reduce analysis time as well as improve precision and allow for automation. However the accurate analysis of more complex environmental samples such as industrial sludges, soil samples, river sediments, and fly ash remains difficult. Numerous contributing factors influence the accuracy of the hydride technique. Sample digestion methods and sample preparation procedures are of critical importance. The digestion must adequately solubilize the elements of interest without loss by volatilization. Sample preparation procedures that guarantee the proper analyte oxidation state and eliminate the nitric acid and inter-element interferences are needed. In this study, difficult environmental samples were analyzed for As, Se, Sb, and Sn by continuous flow hydride generation. Sample preparation methods were optimized to eliminate interferences. The results of spike recovery studies will be presented. Data from the analysis of the same samples by graphite furnace AAS will be presented for comparison of accuracy, precision, and analysis time

  18. Comparison of Antemortem and Environmental Samples for Zebrafish Health Monitoring and Quarantine

    Science.gov (United States)

    Crim, Marcus J; Lawrence, Christian; Livingston, Robert S; Rakitin, Andrei; Hurley, Shane J; Riley, Lela K

    2017-01-01

    Molecular diagnostic assays offer both exquisite sensitivity and the ability to test a wide variety of sample types. Various types of environmental sample, such as detritus and concentrated water, might provide a useful adjunct to sentinels in routine zebrafish health monitoring. Similarly, antemortem sampling would be advantageous for expediting zebrafish quarantine, without euthanasia of valuable fish. We evaluated the detection of Mycobacterium chelonae, M. fortuitum, M. peregrinum, Pseudocapillaria tomentosa, and Pseudoloma neurophilia in zebrafish, detritus, pooled feces, and filter membranes after filtration of 1000-, 500-, and 150-mL water samples by real-time PCR analysis. Sensitivity varied according to sample type and pathogen, and environmental sampling was significantly more sensitive than zebrafish sampling for detecting Mycobacterium spp. but not for Pseudocapillaria neurophilia or Pseudoloma tomentosa. The results of these experiments provide strong evidence of the utility of multiple sample types for detecting pathogens according to each pathogen's life cycle and ecological niche within zebrafish systems. In a separate experiment, zebrafish subclinically infected with M. chelonae, M. marinum, Pleistophora hyphessobryconis, Pseudocapillaria tomentosa, or Pseudoloma neurophilia were pair-spawned and individually tested with subsets of embryos from each clutch that received no rinse, a fluidizing rinse, or were surface-disinfected with sodium hypochlorite. Frequently, one or both parents were subclinically infected with pathogen(s) that were not detected in any embryo subset. Therefore, negative results from embryo samples may not reflect the health status of the parent zebrafish. PMID:28724491

  19. Monitoring PCDD/Fs in soil and herbage samples collected in the neighborhood of a hazardous waste incinerator after five years of operation

    Energy Technology Data Exchange (ETDEWEB)

    Nadal, M.; Bocio, A.; Schuhmacher, M.; Liobet, J.M.; Domingo, J.L. [Rovira i Virgili Univ., Reus (Spain); Diaz-Ferrero, J. [Inst. Quimic de Sarria, Barcelona (Spain)

    2004-09-15

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are among the most dangerous environm