WorldWideScience

Sample records for environmental sample collection

  1. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1997-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL)(a) for the US Department of Energy (DOE). This document contains the planned 1997 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. In addition, Section 3.0, Biota, also reflects a rotating collection schedule identifying the year a specific sample is scheduled for collection. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program, and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling methods will be the same as those described in the Environmental Monitoring Plan, US Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 1, US Department of Energy, Richland, Washington

  2. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program

  3. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program.

  4. Determination of 36Cl in environmental samples collected in the JCO by AMS

    International Nuclear Information System (INIS)

    Seki, R.; Tsukuba Univ., Ibaraki; Arai, D.; Nagashima, Y.; Takahashi, T.; Matsuhiro, T.; Imanaka, T.

    2003-01-01

    Long-lived chlorine, 36 Cl (T 1/2 = 301,000 y) in environmental samples has been measured by the AMS system installed in Tandem Accelerator Center, University of Tsukuba. A tri-carbon-molecular 12 C 3 - pilot beam method is used to stabilize the terminal voltage of the tandem. A small amount of pure carbon graphite is well mixed into a AgCl target material for creating Cl - and 12 C 3 - in the ion source. A 36 S isobaric interference in the system is eliminated to determine 36 Cl in environmental samples by chemical procedure. Some samples containing chlorine such as soil, chemical reagents and table salt have been collected in the JCO criticality accident site and analyzed to detect neutron-induced 36 Cl. The experimental result has been compared with a theoretical calculation. (author)

  5. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    2000-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program: and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling design is described in the Operations Office, Environmental Monitoring Plan, United States Department of Energy, Richland DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY 2000 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2000 in which case the anticipated year for collection is provided. In addition, a map showing approximate sampling locations is included for each media scheduled for collection

  6. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1993-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). Samples are routinely collected and analyzed to determine the quality of air, surface water, ground water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Drinking Water Project, and Ground-Water Surveillance Project.

  7. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  8. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1999-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, ''General Environmental protection Program,'' and DOE Order 5400.5, ''Radiation Protection of the Public and the Environment.'' The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY1999 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes the sampling location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be collected in 1999 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing approximate sampling locations

  9. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site

  10. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.

  11. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  12. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2008-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1, "Environmental Protection Program," and DOE Order 5400.5, "Radiation Protection of the Public and the Environment." The environmental surveillance sampling design is described in the "Hanford Site Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office." This document contains the calendar year 2008 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2008, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2008.

  13. Hanford site environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1998-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1 open-quotes General Environmental Protection Program,close quotes and DOE Order 5400.5, open-quotes Radiation Protection of the Public and the Environment.close quotes The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 2, U.S. Department of Energy, Richland, Washington. This document contains the 1998 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section of this document describes the planned sampling schedule for a specific media (air, surface water, biota, soil and vegetation, sediment, and external radiation). Each section includes the sample location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be planned for 1998 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing sample locations

  14. Methods for the collection of subsurface samples during environmental site assessments

    International Nuclear Information System (INIS)

    Weinstock, E.A.

    1996-01-01

    This paper discusses numerous sample collection techniques that have been successfully employed during Phase 2 Assessments and presents case histories of their application. Pollutants of concern include PCE and petroleum. The collection of shallow soil samples is described using commercially available hand augers and hand-driven core samplers. These devices are modified with extensions to collect deeper samples from storm drains and leaching pools. The performance of soil gas surveys are described using both hand-driven sample probes and vehicle-mounted, hydraulically driven vapor probes. Once the soil vapor is collected at the ground surface, a sample of the media is either analyzed on-site using a field-operated detection device or delivered to a laboratory for analysis. Application and case histories of the Geoprobe(trademark)sampling system, a form of direct push technology, are described. This device uses vehicle-mounted, hydraulically-driven sample probes. The probe can be advanced to depths as great as 100 feet below grade and can retrieve soil, soil gas and groundwater samples

  15. Isolation of Arcobacter butzleri in environmental and food samples collected in industrial and artisanal dairy plants

    Directory of Open Access Journals (Sweden)

    Federica Giacometti

    2013-10-01

    Full Text Available This study investigated the presence of Arcobacter species in two cheese factories; a total of 22 environmental samples and 10 food samples were collected from an artisanal and an industrial cheese factory; Arcobacter species were isolated after enrichment, and isolates were identified at species level by multiplex-polymerase chain reaction (PCR assay. In the artisanal cheese factory, Arcobacter spp. were isolated from several environmental samples, cow and water buffalo raw milk and ricotta cheese. In the industrial plant, Arcobacter spp. were isolated from surfaces not in contact with food and from a cleaned surface in contact with food; no Arcobacter spp. was isolated from food. All isolates were identified as A. butzleri. We report of the presence of A. butzleri in a ready-to-eat cheese produced for retail. In addition, the isolation of A. butzleri in food processing surfaces in the two cheese factories could be assessed as a source of potential contamination for cheeses

  16. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2006

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2006-01-27

    This document contains the calendar year 2006 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2006 in which case the anticipated year for collection is provided. The project document package (PDP) for Surface Environmental Surveillance contains the milestone control log for the issuing of CY06 Environmental Surveillance Master Sampling Schedule WBS 4.2.3.21.3.03, milestone: RL00430306 (4830106-12).

  17. Ground-water sample collection and analysis plan for the ground-water surveillance project

    International Nuclear Information System (INIS)

    Bryce, R.W.; Evans, J.C.; Olsen, K.B.

    1991-12-01

    The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives

  18. Sampling quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces quality assurance guidance pertaining to the design and implementation of sampling procedures and processes for collecting environmental data for DOE's Office of EM (Environmental Restoration and Waste Management)

  19. Collection and preparation of samples for Agency's programme of intercalibration methods and procedures for measurement of environmental radioactivity

    International Nuclear Information System (INIS)

    Patel, B.

    1975-12-01

    In the period of 1971-1975 several samples of marine sediment and organisms were collected from the Bombay Harbour Bay as well as from the vicinity of the Tarapur nuclear power station in order to supply the materials for preparing intercalibration samples for radionuclides measurements. All samples collected were freeze-dried and homogenized prior to the dispatch to the Monaco Laboratory, where final homogenization and the homogeneity tests were carried out. Altogether 2 marine organisms and 3 marine sediments were supplied during this period. The materials supplied were proved to be useful to prepare intercalibration samples for radionuclide measurements in the levels for monitoring operations. Based on these materials several intercalibration exercises were successfully conducted. This work thus formed a basis for bringing the better comparability of radionuclide measurements in marine environmental samples in an international scale

  20. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2010

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2010-01-08

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford Site environs per regulatory requirements. This document contains the calendar year 2010 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2010, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2010.

  1. Collection and preparation of samples for gamma spectrometry

    International Nuclear Information System (INIS)

    Pan Jingquan

    1994-01-01

    The paper presents the basic principles of sample collection and preparation: setting up unified sampling program, methods and procedures, sample packing, transportation and storage, determination of sample quantity, sample pretreatment and preparation of samples to be analysed, etc. for gamma spectrometry. And the paper also describes briefly the main methods and special issues of sampling and preparation for the same environmental and biological samples, such as, air, water, grass, soil and foods

  2. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2009-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  3. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2013-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  4. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2012-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  5. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2009-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author)

  6. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2009

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2009-01-20

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1 and DOE Order 5400.5. This document contains the calendar year 2009 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2009, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2009.

  7. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L E

    1992-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. Samples for radiological analyses include Air-Particulate Filter, gases and vapor; Water/Columbia River, Onsite Pond, Spring, Irrigation, and Drinking; Foodstuffs/Animal Products including Whole Milk, Poultry and Eggs, and Beef; Foodstuffs/Produce including Leafy Vegetables, Vegetables, and Fruit; Foodstuffs/Farm Products including Wine, Wheat and Alfalfa; Wildlife; Soil; Vegetation; and Sediment. Direct Radiation Measurements include Terrestrial Locations, Columbia River Shoreline Locations, and Onsite Roadway, Railway and Aerial, Radiation Surveys.

  8. Scientific guidelines for preservation of samples collected from Mars

    International Nuclear Information System (INIS)

    Gooding, J.L.

    1990-04-01

    The maximum scientific value of Martian geologic and atmospheric samples is retained when the samples are preserved in the conditions that applied prior to their collection. Any sample degradation equates to loss of information. Based on detailed review of pertinent scientific literature, and advice from experts in planetary sample analysis, number values are recommended for key parameters in the environmental control of collected samples with respect to material contamination, temperature, head-space gas pressure, ionizing radiation, magnetic fields, and acceleration/shock. Parametric values recommended for the most sensitive geologic samples should also be adequate to preserve any biogenic compounds or exobiological relics

  9. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons

  10. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons.

  11. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2011

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2011-01-21

    This document contains the calendar year 2011 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2011, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2011.

  12. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2007

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2007-01-31

    This document contains the calendar year 2007 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2007 in which case the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2007.

  13. Radiological analyses of Marshall Islands environmental samples, 1974--1976

    International Nuclear Information System (INIS)

    Greenhouse, N.A.; Miltenberger, R.P.; Cua, F.T.

    1977-01-01

    Results are reported from the radiological analysis of environmental samples collected in the Marshall Islands during 1974 through 1976. Most of the samples were collected on or near the Bikini Atoll and included plants, soil, fish, catchment water, and sediments, with emphasis on local marine and terrestrial food items. Data are presented from γ spectral analysis and the content of 90 Sr and transuranic elements in the samples

  14. Evaluating the reproducibility of environmental radioactivity monitoring data through replicate sample analysis

    International Nuclear Information System (INIS)

    Lindeken, C.L.; White, J.H.; Silver, W.J.

    1978-01-01

    At the Lawrence Livermore Laboratory, about 10% of the sampling effort in the environmental monitoring program represents replicate sample collection. Replication of field samples was initiated as part of the quality assurance program for environmental monitoring to determine the reproducibility of environmental measurements. In the laboratory these replicates are processed along with routine samples. As all components of variance are included in analysis of such field samples, comparison of the analytical data from replicate analyses provides a basis for estimating the overall reproducibility of the measurements. The replication study indicates that the reproducibility of environmental radioactivity monitoring data is subject to considerably more variability than is indicated by the accompanying counting errors. The data are also compared with analyses of duplicate aliquots from a well mixed sample or with duplicate aliquots of samples with known radionuclide content. These comparisons show that most of the variability is associated with the collection and preparation of the sample rather than with the analytical procedures

  15. ICP-MS measurements of iodine and bromine in environmental samples collected along the Kuji River, Japan

    International Nuclear Information System (INIS)

    Kushita, Kouhei N.; Amano, Hikaru

    2003-01-01

    From a viewpoint of monitoring the distribution and transfer of long-lived radioiodine ( 129 I) and possible hazardous brominated substances, I and Br contents in various environmental samples collected in the Kuji River area, Japan, were studied by ICP-MS. The feature of the change in concentrations of I and Br, as well as those of other general properties such as pH etc., in Kuji River watershed were coincident with each other. It is considered from the obtained data that the environmental conditions, especially those of the soil of the area, mainly control the distribution of I and Br in the river water. The circulation characteristics of I and Br showed different features in different transfer media, which could be ascribed to the different chemical properties of these elements in each media. It was also shown that the distributions of I and Br are varied even within a small zone of about 20 km width around a high mountain of this area, which is also considered to reflect the environmental characteristics of the district. (author)

  16. Diagnostic herd sensitivity using environmental samples

    DEFF Research Database (Denmark)

    Vigre, Håkan; Josefsen, Mathilde Hartmann; Seyfarth, Anne Mette

    either at farm or slaughter. Three sample matrices were collected; dust samples (5 environmental swabs), nasal swabs (10 pools with 5 animals per pool) and air samples (1 filter). Based on the assumption that MRSA occurred in all 48 herds the overall herd sensitivity was 58% for nasal swabs, 33% for dust....... In our example, the prevalence of infected pigs in each herd was estimated from the pooled samples of nasal swabs. Logistic regression was used to estimate the effect of animal prevalence on the probability to detect MRSA in the dust and air samples at herd level. The results show a significant increase...

  17. Environmental monitoring master sampling schedule: January--December 1989

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1989-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1989 for the Surface and Ground-Water Environmental Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. This schedule includes routine ground-water sampling performed by PNL for Westinghouse Hanford Company, but does not include samples that may be collected in 1989 to support special studies or special contractor projects, or for quality control. The sampling schedule for Site-wide chemical monitoring is not included here, because it varies each quarter as needed, based on past results and operating needs. This schedule does not include Resource Conservation and Recovery Act ground-water sampling performed by PNL for Hanford Site contractors, nor does it include sampling that may be done by other DOE Hanford contractors

  18. A method to combine non-probability sample data with probability sample data in estimating spatial means of environmental variables

    NARCIS (Netherlands)

    Brus, D.J.; Gruijter, de J.J.

    2003-01-01

    In estimating spatial means of environmental variables of a region from data collected by convenience or purposive sampling, validity of the results can be ensured by collecting additional data through probability sampling. The precision of the pi estimator that uses the probability sample can be

  19. Sample preparation of environmental samples using benzene synthesis followed by high-performance LSC

    International Nuclear Information System (INIS)

    Filippis, S. De; Noakes, J.E.

    1991-01-01

    Liquid scintillation counting (LSC) techniques have been widely employed as the detection method for determining environmental levels of tritium and 14 C. Since anthropogenic and nonanthropogenic inputs to the environment are a concern, sampling the environment surrounding a nuclear power facility or fuel reprocessing operation requires the collection of many different sample types, including agriculture products, water, biota, aquatic life, soil, and vegetation. These sample types are not suitable for the direct detection of tritium of 14 C for liquid scintillation techniques. Each sample type must be initially prepared in order to obtain the carbon or hydrogen component of interest and present this in a chemical form that is compatible with common chemicals used in scintillation counting applications. Converting the sample of interest to chemically pure benzene as a sample preparation technique has been widely accepted for processing samples for radiocarbon age-dating applications. The synthesized benzene is composed of the carbon or hydrogen atoms from the original sample and is ideal as a solvent for LSC with excellent photo-optical properties. Benzene synthesis followed by low-background scintillation counting can be applied to the preparation and measurement of environmental samples yielding good detection sensitivities, high radionuclide counting efficiency, and shorter preparation time. The method of benzene synthesis provides a unique approach to the preparation of a wide variety of environmental sample types using similar chemistry for all samples

  20. Evaluation of environmental sampling methods for detection of Salmonella enterica in a large animal veterinary hospital.

    Science.gov (United States)

    Goeman, Valerie R; Tinkler, Stacy H; Hammac, G Kenitra; Ruple, Audrey

    2018-04-01

    Environmental surveillance for Salmonella enterica can be used for early detection of contamination; thus routine sampling is an integral component of infection control programs in hospital environments. At the Purdue University Veterinary Teaching Hospital (PUVTH), the technique regularly employed in the large animal hospital for sample collection uses sterile gauze sponges for environmental sampling, which has proven labor-intensive and time-consuming. Alternative sampling methods use Swiffer brand electrostatic wipes for environmental sample collection, which are reportedly effective and efficient. It was hypothesized that use of Swiffer wipes for sample collection would be more efficient and less costly than the use of gauze sponges. A head-to-head comparison between the 2 sampling methods was conducted in the PUVTH large animal hospital and relative agreement, cost-effectiveness, and sampling efficiency were compared. There was fair agreement in culture results between the 2 sampling methods, but Swiffer wipes required less time and less physical effort to collect samples and were more cost-effective.

  1. Fast egg collection method greatly improves randomness of egg sampling in Drosophila melanogaster

    DEFF Research Database (Denmark)

    Schou, Mads Fristrup

    2013-01-01

    When obtaining samples for population genetic studies, it is essential that the sampling is random. For Drosophila, one of the crucial steps in sampling experimental flies is the collection of eggs. Here an egg collection method is presented, which randomizes the eggs in a water column...... and diminishes environmental variance. This method was compared with a traditional egg collection method where eggs are collected directly from the medium. Within each method the observed and expected standard deviations of egg-to-adult viability were compared, whereby the difference in the randomness...... and to obtain a representative collection of genotypes, the method presented here is strongly recommended when collecting eggs from Drosophila....

  2. Environmental monitoring master sampling schedule, January--December 1990

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1990-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1990 for the Environment Surveillance and Ground-Water Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This schedule includes ground-water sampling performed by PNL for environmental surveillance of the Hanford Site.

  3. Detection and Molecular Characterization of Gemycircularvirus from Environmental Samples in Brazil.

    Science.gov (United States)

    da Silva Assis, Matheus Ribeiro; Vieira, Carmen Baur; Fioretti, Julia Monassa; Rocha, Mônica Simões; de Almeida, Pedro Ivo Neves; Miagostovich, Marize Pereira; Fumian, Tulio Machado

    2016-12-01

    Gemycircularvirus (GemyCV) is a group of viruses which has been recently proposed as a new viral genus detected in fecal and environmental samples around the world. GemyCVs have been detected in human blood, brain tissue, cerebrospinal fluid, and stool sample. In the present study, we demonstrate for the first time, through molecular detection and characterization, the presence of GemyCVs in environmental samples from Brazil. Our results show a percentage of positivity ranging from 69 (25/36) to 97 % (35/36) in river water samples collected in Manaus, Amazon region, and wastewater from a wastewater treatment plant located in Rio de Janeiro, respectively, revealing GemyCVs as an important environmental contaminant.

  4. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2005

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2005-01-19

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This document contains the calendar year 2005 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project.

  5. [Detection of Avian Influenza Virus in Environmental Samples Collected from Live Poultry Markets in China during 2009-2013].

    Science.gov (United States)

    Zhang, Ye; Li, Xiaodan; Zou, Shumei; Bo, Hong; Dong, Libo; Gao, Rongbao; Wang, Dayan; Shu, Yuelong

    2015-11-01

    Abstract: To investigate the distribution of avian influenza virus in environmental samples from live poultry markets (LPM) in China, samples were collected and tested by nucleic acid during 2009-2013 season. Each sample was tested by real-time RT PCR using flu A specific primers. If any real-time PCR was positive, the sample was inoculated into specific-pathogen-free (SPF) embryonated chicken eggs for viral isolation. The results indicated that the positive rate of nucleic acid in enviromental samples exhibited seasonality. The positive rate of nucleic acid was significantly higher in Winter and Spring. The positive rate of nucleic acid in LPM located in the south of China was higher than in northern China. Samples of Sewage for cleaning poultry and chopping board showed that higher positive rate of nucleic acid than other samples. The Subtype identification showed that H5 and H9 were main subtypes in the enviromental samples. Viral isolation indicated H5 subtypes was more than H9 subtypes between 2009 and 2013 while H9 subtypes increased in 2013. Our findings suggested the significance of public health based on LPM surveillance and provided the basis of prevention and early warning for avian flu infection human.

  6. Environmental sampling accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-06-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an on-line disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished by using computer-generated schedules, collection labels, and output/input cards. For each scheduled sample and analysis, a printed card is issued for collection, laboratory analysis, and counting. The cards also contain information needed by personnel performing the jobs, such as sample location, aliquot to be processed, or procedure number. Manual entries are made on the cards when each step in the process is completed. Additional pertinent data are also manually entered on the cards; e.g., entries are made explaining why a sample is not collected, the sample aliquot in the event a nonstandard aliquot is processed, field measurement results, and analytical results. These manually entered data are keypunched and read into the computer files. The computer files are audited daily, and summaries of samples not processed in pre-established normal time intervals are issued. The progress of sample analyses can also be readily determined at any time using the CRT terminal. Historic data are also maintained on magnetic tape and workload summaries are issued showing the number of samples and number of determinations per month

  7. Sample collection and documentation

    International Nuclear Information System (INIS)

    Cullings, Harry M.; Fujita, Shoichiro; Watanabe, Tadaaki; Yamashita, Tomoaki; Tanaka, Kenichi; Endo, Satoru; Shizuma, Kiyoshi; Hoshi, Masaharu; Hasai, Hiromi

    2005-01-01

    Beginning within a few weeks after the bombings and periodically during the intervening decades, investigators in Hiroshima and Nagasaki have collected samples of materials that were in the cities at the time of the bombings. Although some early efforts were not driven by specific measurement objectives, many others were. Even some of the very earliest samples collected in 1945 were based on carefully conceived research plans and detailed specifications for samples appropriate to particular retrospective measurements, i.e., of particular residual quantities remaining from exposure to the neutrons and gamma rays from the bombs. This chapter focuses mainly on the work of groups at two institutions that have actively collaborated since the 1980s in major collection efforts and have shared samples among themselves and with other investigators: the Radiation Effects Research Foundation (RERF) and its predecessor the Atomic Bomb Casualty Commission (ABCC), and Hiroshima University. In addition, a number of others are listed, who also contributed to the literature by their collection of samples. (J.P.N.)

  8. Molecular detection of native and invasive marine invertebrate larvae present in ballast and open water environmental samples collected in Puget Sound

    Science.gov (United States)

    Harvey, J.B.J.; Hoy, M.S.; Rodriguez, R.J.

    2009-01-01

    Non-native marine species have been and continue to be introduced into Puget Sound via several vectors including ship's ballast water. Some non-native species become invasive and negatively impact native species or near shore habitats. We present a new methodology for the development and testing of taxon specific PCR primers designed to assess environmental samples of ocean water for the presence of native and non-native bivalves, crustaceans and algae. The intergenic spacer regions (IGS; ITS1, ITS2 and 5.8S) of the ribosomal DNA were sequenced for adult samples of each taxon studied. We used these data along with those available in Genbank to design taxon and group specific primers and tested their stringency against artificial populations of plasmid constructs containing the entire IGS region for each of the 25 taxa in our study, respectively. Taxon and group specific primer sets were then used to detect the presence or absence of native and non-native planktonic life-history stages (propagules) from environmental samples of ballast water and plankton tow net samples collected in Puget Sound. This methodology provides an inexpensive and efficient way to test the discriminatory ability of taxon specific oligonucleotides (PCR primers) before creating molecular probes or beacons for use in molecular ecological applications such as probe hybridizations or microarray analyses. This work addresses the current need to develop molecular tools capable of diagnosing the presence of planktonic life-history stages from non-native marine species (potential invaders) in ballast water and other environmental samples. ?? 2008 Elsevier B.V.

  9. Master schedule for CY-1984 Hanford environmental surveillance routine sampling program

    International Nuclear Information System (INIS)

    Blumer, P.J.; Price, K.R.; Eddy, P.A.; Carlile, J.M.V.

    1983-12-01

    This report provides the current schedule of data collection for the routine Hanford environmental surveillance and ground-water Monitoring Programs at the Hanford Site. The purpose is to evaluate and report the levels of radioactive and nonradioactive pollutants in the Hanford environs. The routine sampling schedule provided herein does not include samples that are planned to be collected during FY-1984 in support of special studies, special contractor support programs, or for quality control purposes

  10. Environmental sample accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-01-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an online disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished using computer-generated schedules, bottle labels, and output/ input cards. A printed card is issued for the collecting, analyzing, and counting of each scheduled sample. The card also contains information for the personnel who are to perform the work, e.g., sample location, aliquot to be processed, and procedure to be used. Manual entries are made on the card when each step in the process is completed. Additional pertinent data such as the reason a sample is not collected, the need for a nonstandard aliquot, and field measurement results are keypunched and then read into the computer files as required. The computer files are audited daily and summaries showing samples not processed in pre-established normal schedules are provided. The progress of sample analyses is readily determined at any time using the CRT terminal. Historic data are maintained on magnetic tape, and workload summaries showing the number of samples and number of determinations per month are issued. (author)

  11. Stability of metal ions in aqueous environmental samples

    International Nuclear Information System (INIS)

    Rattonetti, A.

    1976-01-01

    The time lapse between the collection of aqueous environmental samples and the analysis affects the original ionic concentration. Studies have proven the nonionic species in a water sample have more of an effect on the veracity of an analysis than the ''container wall'' effect, and that adjustment to a pH of 2 at sample collection time is a ''Pyrrhic victory.'' Lead, for example, will commonly increase an order of magnitude when unfiltered samples are adjusted to a pH of 2 upon collection. This effect is greatest when elemental ions are present in the ng ml -1 range and lessens as the original ionic concentration increases. Data are presented that behooves filtration of stream water and rainwater samples prior to any acidification step. The need to acidify the resulting filtrate is also discussed. Lithium, sodium, potassium, cesium, magnesium, calcium, strontium, manganese, iron, copper, silver, zinc, cadmium, aluminum, indium, and lead are examined. The insoluble phase retained on the filter can be digested with acid and also analyzed. The separate analysis of the filtrate and filter will give a true representation of the occurrence of these metals in nature. Flame and flameless atomic aborption and emission are used to perform the trace analyses

  12. Guidance for establishment and implementation of a national sample management program in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. Therefore the NSMP's primary role is to coordinate and function as a central repository for information collected from the FSMPs. An additional role of the NSMP is to monitor trends in data collected from the FSMPs over time and across sites and laboratories. Tracking these trends will allow identification of potential problems in the sampling and analysis process

  13. Environmental sampling

    International Nuclear Information System (INIS)

    Puckett, J.M.

    1998-01-01

    Environmental Sampling (ES) is a technology option that can have application in transparency in nuclear nonproliferation. The basic process is to take a sample from the environment, e.g., soil, water, vegetation, or dust and debris from a surface, and through very careful sample preparation and analysis, determine the types, elemental concentration, and isotopic composition of actinides in the sample. The sample is prepared and the analysis performed in a clean chemistry laboratory (CCL). This ES capability is part of the IAEA Strengthened Safeguards System. Such a Laboratory is planned to be built by JAERI at Tokai and will give Japan an intrinsic ES capability. This paper presents options for the use of ES as a transparency measure for nuclear nonproliferation

  14. Experience with environmental sampling at gas centrifuge enrichment plants

    International Nuclear Information System (INIS)

    Ekenstam, G. af; Bush, W.; Janov, J.; Kuhn, E.; Ryjinski, M.

    2001-01-01

    Environmental sampling has been used routinely by the IAEA since 1996 after the IAEA Board of Governors approved it in March 1995 as a new technique to strengthen safeguards and improve efficiency. In enrichment plants it is used to confirm that there has been no production of highly enriched uranium (HEU), or production of uranium at above the declared enrichment. The use of environmental sampling is based on the assumption that every process, no matter how leak tight, will release small amounts of process material to the environment. Even though these releases of nuclear material are extremely small in gas centrifuge enrichment plants, and well below levels of concern from a health physics and safety standpoint, they are detectable and their analysis provides an indication of the enrichment of the material that has been processed in the plant. The environmental samples at enrichment plants are collected by swiping selected areas of the plant with squares of cotton cloth (10x10 cm) from sampling kits prepared in ultra clean condition. The squares of cotton cloth sealed in plastic bags are sent for analysis to the Network Analytical Laboratories. The analysis includes the measurement of the uranium isotopic composition in uranium-containing particles by Thermal lonization Mass Spectroscopy (TIMS) or Secondary ION Mass Spectroscopy (SIMS). Since the implementation of environmental sampling, swipes have been collected from 240 sampling points at three gas centrifuge plants of URENCO, which have a total throughput of more than 8,000 tonnes of uranium per year. The particle analysis results generally reflected the known operational history of the plants and confirmed that they had only been operated to produce uranium with enrichment less than 5% 235 U. The information about the content of the minor isotopes 234 U and 236 U also indicates that depleted and recycled uranium were sometimes used as feed materials in some plants. An example is given of the TIMS particle

  15. Guidance for establishment and implementation of field sample management programs in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. The purpose of this document is to establish the suggested scope of the FSMP activities to be performed under each Operations Office, list the drivers under which the program will operate, define terms and list references. This guidance will apply only to EM sampling and analysis activities associated with project planning, contracting, laboratory selection, sample collection, sample transportation, laboratory analysis and data management

  16. The role of NAA in the environmental studies. Quantitative determination of heavy metals pollutant on environmental samples

    International Nuclear Information System (INIS)

    Sutisna; Yusuf, Saeful; Fisli, Adel; Rukihati; Wardhani, Sri; Th Rina M

    2003-01-01

    The neutron activation analysis technique was applied in the elemental analysis of environmental samples to solve an environmental pollution problem. We focused our study in the analysis of heavy metal which has potentially become a pollutant. The environmental samples analyzed were some water, sediment and an air particulate matter. The tap water sample was collected from five samplings points located at region of Serpong and Muria. Meanwhile the river water samples were taken from five samplings points of Ciliwung River. Eight samplings points of Cisadane river estuary located at Tanjung Burung were selected to collect sediment samples. Air particulate samples were collected from Jakarta Metropolitan and Serpong using high volume air sampler. Trace elements analyses of water samples were done using a combination of INAA and pre-concentration stage prior irradiation. All samples were irradiated at GA. Siwabessy reactor located at Serpong using a thermal neutron flux of about 10 12 n.cm -2 .sec -1 . After cooling time, the samples irradiated were counted by a high resolution HPGe detector coupled to a multichannel analyzer. The quantitative analyses have been done using a comparative method to a fresh laboratory standard and we used some standard references materials to validate our analytical result. The obtained result from the tap water analysis show that the elements of As, Cr, Co, Cd, Mn, Sb and Zn could be determine quantitatively and they have a concentration range from about 0.02 μg/L to 103.9 μg/L. The analysis result of Ciliwung river water samples show that elements of Ag, As, Co, Cu, Fe, Hg, Mn, V and Zn are present in the range of 2.4 μg/L to about 1365.8 μg/L. Meanwhile some important elements were obtained in the sediments samples taken from Cisadane River estuary such as Ce (40.4 - 63.6 mg/kg), Co (15.2 - 40.2 mg/kg), Cr (21.6 - 57.8 mg/kg), Eu (1.2 - 1.8 mg/kg), Fe (7.0 - 16.8 mg/kg), Mn (887 - 1810 mg/kg) and V (160 - 558 mg/kg). Finally the

  17. Radioactivity in environmental samples

    International Nuclear Information System (INIS)

    Fornaro, Laura

    2001-01-01

    The objective of this practical work is to familiarize the student with radioactivity measures in environmental samples. For that were chosen samples a salt of natural potassium, a salt of uranium or torio and a sample of drinkable water

  18. Neutron activation analysis for environmental sample in Thailand

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Nouchpramool, Sunun; Bunprapob, Supamatthree; Sumitra, Tatchai

    2003-01-01

    Neutron Activation Analysis has been applied for the trace elements analysis in environmental samples. Thirty three samples of airborne particulate were collected every week at Ongkharak Nuclear Research Center (ONRC) during the period of June 1998 to March 1999. The Ti, I, Mg, Na, V, K, Cl, Al, Mn, Ca, As, Sm, Sb, Br, La, Ce, Th, Cr, Cs, Sc, Rb, Fe, Zn and Co were analyzed by Neutron Activation Analysis utilizing 2 MW TRIGA MARK III research reactor. The certified reference materials 1632a and 1633a from National Bureau of Standard were select as standard. (author)

  19. Historical review of long-term soil sampling for environmental surveillance at the Hanford Site and vicinity

    Energy Technology Data Exchange (ETDEWEB)

    Price, K.R.; Rickard, W.H.

    1997-08-01

    Soil samples have been collected routinely from the environs of the Hanford Site and analyzed since 1971. Correct interpretation of results depends on samples being collected from the same locations, the locations remaining relatively undisturbed, and collection and analytical procedures remaining the same or being equivalent. Historical files, documents, and annual environmental reports were reviewed to evaluate these factors. It was determined that 20 soil sampling locations, 11 onsite and 9 offsite, were established between 1971 and 1977 and represent long-term sampling locations. Sample collection and analytical procedures have remained essentially the same since 1971. The physical ecological attributes of each long-term soil sampling location were evaluated. During the review of historical records, a few results for 1970, 1971, and 1972 were noted as previously unreported in annual or special reports. These results are included in Appendix A. To complete the record, results previously reported in annual environmental reports are given in Appendix B. Global Positioning System (GPS) reading for 20 long-term soil sampling locations are provided in Appendix C.

  20. Historical review of long-term soil sampling for environmental surveillance at the Hanford Site and vicinity

    International Nuclear Information System (INIS)

    Price, K.R.; Rickard, W.H.

    1997-08-01

    Soil samples have been collected routinely from the environs of the Hanford Site and analyzed since 1971. Correct interpretation of results depends on samples being collected from the same locations, the locations remaining relatively undisturbed, and collection and analytical procedures remaining the same or being equivalent. Historical files, documents, and annual environmental reports were reviewed to evaluate these factors. It was determined that 20 soil sampling locations, 11 onsite and 9 offsite, were established between 1971 and 1977 and represent long-term sampling locations. Sample collection and analytical procedures have remained essentially the same since 1971. The physical ecological attributes of each long-term soil sampling location were evaluated. During the review of historical records, a few results for 1970, 1971, and 1972 were noted as previously unreported in annual or special reports. These results are included in Appendix A. To complete the record, results previously reported in annual environmental reports are given in Appendix B. Global Positioning System (GPS) reading for 20 long-term soil sampling locations are provided in Appendix C

  1. Zoonotic pathogens isolated from wild animals and environmental samples at two California wildlife hospitals.

    Science.gov (United States)

    Siembieda, Jennifer L; Miller, Woutrina A; Byrne, Barbara A; Ziccardi, Michael H; Anderson, Nancy; Chouicha, Nadira; Sandrock, Christian E; Johnson, Christine K

    2011-03-15

    To determine types and estimate prevalence of potentially zoonotic enteric pathogens shed by wild animals admitted to either of 2 wildlife hospitals and to characterize distribution of these pathogens and of aerobic bacteria in a hospital environment. Cross-sectional study. Fecal samples from 338 animals in 2 wildlife hospitals and environmental samples from 1 wildlife hospital. Fecal samples were collected within 24 hours of hospital admission. Environmental samples were collected from air and surfaces. Samples were tested for zoonotic pathogens via culture techniques and biochemical analyses. Prevalence of pathogen shedding was compared among species groups, ages, sexes, and seasons. Bacterial counts were determined for environmental samples. Campylobacter spp, Vibrio spp, Salmonella spp, Giardia spp, and Cryptosporidium spp (alone or in combination) were detected in 105 of 338 (31%) fecal samples. Campylobacter spp were isolated only from birds. Juvenile passerines were more likely to shed Campylobacter spp than were adults; prevalence increased among juvenile passerines during summer. Non-O1 serotypes of Vibrio cholerae were isolated from birds; during an oil-spill response, 9 of 10 seabirds screened were shedding this pathogen, which was also detected in environmental samples. Salmonella spp and Giardia spp were isolated from birds and mammals; Cryptosporidium spp were isolated from mammals only. Floors of animal rooms had higher bacterial counts than did floors with only human traffic. Potentially zoonotic enteric pathogens were identified in samples from several species admitted to wildlife hospitals, indicating potential for transmission if prevention is not practiced.

  2. The role of NAA in the environmental studies. Quantitative determination of heavy metals pollutant on environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Sutisna; Yusuf, Saeful; Fisli, Adel; Rukihati; Wardhani, Sri; Th Rina M [National Nuclear Energy Agency of Indonesia, Kawasan Puspiptek, Serpong (Indonesia)

    2003-03-01

    The neutron activation analysis technique was applied in the elemental analysis of environmental samples to solve an environmental pollution problem. We focused our study in the analysis of heavy metal which has potentially become a pollutant. The environmental samples analyzed were some water, sediment and an air particulate matter. The tap water sample was collected from five samplings points located at region of Serpong and Muria. Meanwhile the river water samples were taken from five samplings points of Ciliwung River. Eight samplings points of Cisadane river estuary located at Tanjung Burung were selected to collect sediment samples. Air particulate samples were collected from Jakarta Metropolitan and Serpong using high volume air sampler. Trace elements analyses of water samples were done using a combination of INAA and pre-concentration stage prior irradiation. All samples were irradiated at GA. Siwabessy reactor located at Serpong using a thermal neutron flux of about 10{sup 12} n.cm{sup -2}.sec{sup -1}. After cooling time, the samples irradiated were counted by a high resolution HPGe detector coupled to a multichannel analyzer. The quantitative analyses have been done using a comparative method to a fresh laboratory standard and we used some standard references materials to validate our analytical result. The obtained result from the tap water analysis show that the elements of As, Cr, Co, Cd, Mn, Sb and Zn could be determine quantitatively and they have a concentration range from about 0.02 {mu}g/L to 103.9 {mu}g/L. The analysis result of Ciliwung river water samples show that elements of Ag, As, Co, Cu, Fe, Hg, Mn, V and Zn are present in the range of 2.4 {mu}g/L to about 1365.8 {mu}g/L. Meanwhile some important elements were obtained in the sediments samples taken from Cisadane River estuary such as Ce (40.4 - 63.6 mg/kg), Co (15.2 - 40.2 mg/kg), Cr (21.6 - 57.8 mg/kg), Eu (1.2 - 1.8 mg/kg), Fe (7.0 - 16.8 mg/kg), Mn (887 - 1810 mg/kg) and V (160 - 558

  3. Analytical laboratory quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces QA guidance pertaining to design and implementation of laboratory procedures and processes for collecting DOE Environmental Restoration and Waste Management (EM) ESAA (environmental sampling and analysis activities) data. It addresses several goals: identifying key laboratory issues and program elements to EM HQ and field office managers; providing non-prescriptive guidance; and introducing environmental data collection program elements for EM-263 assessment documents and programs. The guidance describes the implementation of laboratory QA elements within a functional QA program (development of the QA program and data quality objectives are not covered here)

  4. Determination of strontium-90 in the environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Perveen, N.; Aziz, A.

    1979-01-01

    Strontium-90 a bone seeking radionuclide and a long lived beta emitter is one of the toxic radionuclides detected in the environment arising mainly from the fall out from nuclear detonations. Its concentration in various environmental media such as air, precipitation, surface water, vegetables and other items of diet was measured. This report describes the method of collection, treatment and radiochemical analyses of environmental samples for the determination of Sr-90. The levels of Sr-90 concentration in these media are also recorded. (authors)

  5. Environmental sampling for trace analysis

    International Nuclear Information System (INIS)

    Markert, B.

    1994-01-01

    Often too little attention is given to the sampling before and after actual instrumental measurement. This leads to errors, despite increasingly sensitive analytical systems. This is one of the first books to pay proper attention to representative sampling. It offers an overview of the most common techniques used today for taking environmental samples. The techniques are clearly presented, yield accurate and reproducible results and can be used to sample -air - water - soil and sediments - plants and animals. A comprehensive handbook, this volume provides an excellent starting point for researchers in the rapidly expanding field of environmental analysis. (orig.)

  6. DOE methods for evaluating environmental and waste management samples

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K. [eds.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  7. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, open-quotes Draftclose quotes or open-quotes Verifiedclose quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy

  8. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Laboratory Management Division of the DOE. Methods are prepared for entry into DOE Methods as chapter editors, together with DOE and other participants in this program, identify analytical and sampling method needs. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types. open-quotes Draftclose quotes or open-quotes Verified.close quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations

  9. Soil sampling for environmental contaminants

    International Nuclear Information System (INIS)

    2004-10-01

    The Consultants Meeting on Sampling Strategies, Sampling and Storage of Soil for Environmental Monitoring of Contaminants was organized by the International Atomic Energy Agency to evaluate methods for soil sampling in radionuclide monitoring and heavy metal surveys for identification of punctual contamination (hot particles) in large area surveys and screening experiments. A group of experts was invited by the IAEA to discuss and recommend methods for representative soil sampling for different kinds of environmental issues. The ultimate sinks for all kinds of contaminants dispersed within the natural environment through human activities are sediment and soil. Soil is a particularly difficult matrix for environmental pollution studies as it is generally composed of a multitude of geological and biological materials resulting from weathering and degradation, including particles of different sizes with varying surface and chemical properties. There are so many different soil types categorized according to their content of biological matter, from sandy soils to loam and peat soils, which make analytical characterization even more complicated. Soil sampling for environmental monitoring of pollutants, therefore, is still a matter of debate in the community of soil, environmental and analytical sciences. The scope of the consultants meeting included evaluating existing techniques with regard to their practicability, reliability and applicability to different purposes, developing strategies of representative soil sampling for cases not yet considered by current techniques and recommending validated techniques applicable to laboratories in developing Member States. This TECDOC includes a critical survey of existing approaches and their feasibility to be applied in developing countries. The report is valuable for radioanalytical laboratories in Member States. It would assist them in quality control and accreditation process

  10. Comparative evaluation of the US Environmental Protection Agency's and the Oak Ridge Institute for Science and Education's environmental survey and site assessment program field sampling procedures

    International Nuclear Information System (INIS)

    Vitkus, T.J.; Bright, T.L.; Roberts, S.A.

    1997-10-01

    At the request of the U.S. Nuclear Regulatory Commission's (NRC's) Headquarters Office, the Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) compared the documented procedures that the U.S. Environmental Protection Agency (EPA) and ESSAP use for collecting environmental samples. The project objectives were to review both organizations' procedures applicable to collecting various sample matrices, compare the procedures for similarities and differences, and then to evaluate the reason for any identified procedural differences and their potential impact on ESSAP's sample data quality. The procedures reviewed included those for sampling surface and subsurface soil, surface and groundwater, vegetation, air, and removable surface contamination. ESSAP obtained copies of relevant EPA documents and reviewed and prepared a tabulated summary of each applicable procedure. The methods for collecting and handling each type of sample were evaluated for differences, and where these were identified, the significance and effect of the differences on analytical quality were determined. The results of the comparison showed that, overall, the procedures and methods that EPA and ESSAP use for sample collection are very similar. The number of minor differences noted were the result of restrictions or procedures necessary to ensure sample integrity and prevent the introduction of interfering compounds when samples are to be analyzed for chemical parameters. For most radio nuclide analyses, these additional procedures are not necessary. Another item noted was EPA's inclusion of steps that reduce the potential for sample cross-contamination by preparing (dressing) a location prior to collecting a sample or removing a portion of a sample prior to containerization

  11. Compendium of Environmental Sustainability Indicator Collections: Complete Collection, Version 1.1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Compendium of Environmental Sustainability Indicator Collections, Version 1.1 contains 426 indicators for 239 countries from five major environmental...

  12. Is there an environmentally optimal separate collection rate?

    Science.gov (United States)

    Haupt, M; Waser, E; Würmli, J C; Hellweg, S

    2018-04-20

    Material recycling often leads to environmental benefits when compared to thermal treatments or landfilling and is therefore positioned in the waste hierarchy as the third priority after waste prevention and reuse. To assess the environmental impacts of recycling and the related substitution of primary material, linear steady-state models of physical flows are typically used. In reality, the environmental burdens of collection and recycling are likely to be a non-linear function of the collection rate. This short communication aims at raising awareness of the non-linear effects in separate collection systems and presents the first non-linear quantitative model for PET bottle recycling. The influence of collection rates on the material quality and the transport network is analyzed based on the data collected from industrial partners. The results highlight that in the present Swiss recycling system a very high collection rate close to 100% yields optimum environmental benefits with respect to global warming. The empirical data, however, provided indications for a decrease in the marginal environmental benefit of recycling. This can be seen as an indication that tipping points may exist for other recycling systems, in which the environmental benefits from substituting primary materials are less pronounced than they are for PET. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Recent tritium levels in environmental waters collected at the drainage basin of Changjiang (Yangtze River)

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Osamu; Nakagawa, Takao; Hashimoto, Tetsuo [Niigata Univ. (Japan)

    1989-11-01

    This paper reports tritium levels in environmental waters in the China in comparison with those in Japan. Environmental water samples were collected in October-November 1987 from the drainage basin of Changjiang from Sichuan through Hubei districts. Tritium levels were 0.22 Bq/l-6.73 Bq/l (an average, 3.09{plus minus}1.18 Bq/l) in 50 ground water samples; 3.40 Bq/l-3.81 Bq/l (an average, 3.71{plus minus}0.81 Bq/l) in four river samples collected from the main course of the Changjiang River; 1.74 Bq/l-5.40 Bq/l (an average, 3.14{plus minus}1.52 Bq/l) in four river samples collected from the tributary river; and 0.63 Bq/l and 1.78 Bq/l in precipitation samples. Environmental waters contained a large quantity of Ca{sup 2+} and Mg{sup 2+} ions, irrespective of river and ground water samples. In comparing tritium levels in environmental waters in the China and Japan, tritium levels were higher in the ground water influenced by a landslide in the China than Japan. Tritium levels in precipitations collected from the drainage basin of the Changjiang were similar to those in Niigata (Japan), 0.63{plus minus}0.26 Bq/l and 1.78{plus minus}0.26 Bq/l vs 0.53{plus minus}0.36 Bq/l - 2.17{plus minus}0.40 Bq/l. The concentrations of Ca{sup 2+}, Mg{sup 2+}, and HCO{sub 3}{sup -} were higher in the Changjiang River (4 water samples) than the river waters, including the Shinano River in Japan. The concentrations of Na{sup +} and Cl{sup -} were higher in the Changjiang River than the average concentrations in the Japanese rivers, but lower than the Shinano River (Japan). A small quantity of precipitations and width of the Changjiang River, as well as nuclear explosion test performed up to 1980, seem to influence higher tritium levels in the Changjiang than those in Japan. (N.K.).

  14. Prevalence of L. monocytogenes in environmental samples collected in dairy plants of Sassari Province, Italy

    Directory of Open Access Journals (Sweden)

    Giovanni Terrosu

    2015-09-01

    Full Text Available Listeria (L. monocytogenes is frequently isolated from food production environment and often persists in dairy plants despite vigorous sanitation regimes. In recent years several alert notifications were sent to Rapid Alert System for Food Products system as a consequence of Listeria monocytogenes contamination of ricotta cheese. After the alert of 2012, competent authority (Local Health Unit of Sassari Province organised an environmental monitoring plan with the partnership of the Institute for Experimental Veterinary Medicine of Sardinia to verify analysis of dairy plants own-check according to Regulation (EC N° 2073/05 and further modifications. In 2014 n. 665 processing areas samples of n. 50 dairy plants of Sassari Province were examined. UNI EN ISO 11290-1:2005 for detection of L. monocytogenes was used. Non-compliance in n. 5 diary plants are observed (n. 8 positive samples. Post-non-compliance environmental sanitisation was efficient and own-check plans included appropriate corrective actions.

  15. Use of immunomagnetic separation for the detection of Desulfovibrio vulgaris from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, R.; Hazen, T.C.; Joyner, D.C.; Kusel, K.; Singer, M.E.; Sitte, J.; Torok, T.

    2011-04-15

    Immunomagnetic separation (IMS) has proved highly efficient for recovering microorganisms from heterogeneous samples. Current investigation targeted the separation of viable cells of the sulfate-reducing bacterium, Desulfovibrio vulgaris. Streptavidin-coupled paramagnetic beads and biotin labeled antibodies raised against surface antigens of this microorganism were used to capture D. vulgaris cells in both bioreactor grown laboratory samples and from extremely low-biomass environmental soil and subsurface drilling samples. Initial studies on detection, recovery efficiency and viability for IMS were performed with laboratory grown D. vulgaris cells using various cell densities. Efficiency of cell isolation and recovery (i.e., release of the microbial cells from the beads following separation) was followed by microscopic imaging and acridine orange direct counts (AODC). Excellent recovery efficiency encouraged the use of IMS to capture Desulfovibrio spp. cells from low-biomass environmental samples. The environmental samples were obtained from a radionuclide-contaminated site in Germany and the chromium (VI)-contaminated Hanford site, an ongoing bioremediation project of the U.S. Department of Energy. Field deployable IMS technology may greatly facilitate environmental sampling and bioremediation process monitoring and enable transcriptomics and proteomics/metabolomics-based studies directly on cells collected from the field.

  16. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    Energy Technology Data Exchange (ETDEWEB)

    Marberry, Hugh [SRNS Savannah River Site 730-4B Room 3043 Aiken, SC 29808 (United States); Moore, Winston [SRNS Savannah River Site 735B Room 116 Aiken, SC 29808 (United States)

    2013-07-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

  17. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    International Nuclear Information System (INIS)

    Marberry, Hugh; Moore, Winston

    2013-01-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

  18. Isotope dilution and sampling factors of the quality assurance and TQM of environmental analysis

    International Nuclear Information System (INIS)

    Macasek, F.

    1999-01-01

    Sampling and preparatory treatment of environmental objects is discussed from the view of their information content, functional speciation of the pollutant, statistical distribution treatment and uncertainty assessment. During homogenization of large samples, a substantial information may be lost and validity of environmental information becomes vague. Isotope dilution analysis is discussed as the most valuable tool for both validity of analysis and evaluation of samples variance. Data collection for a non-parametric statistical treatment of series of 'non-representative' sub-samples, and physico-chemical speciation of analyte may actually better fulfill criteria of similarity and representativeness. Large samples are often required due to detection limits of analysis, but the representativeness of environmental samples should by understood not only by the mean analyte concentration, but also by its spatial and time variance. Hence, heuristic analytical scenarios and interpretation of results must be designed by cooperation of environmentalists and analytical chemists. (author)

  19. Practical reporting times for environmental samples

    International Nuclear Information System (INIS)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4 degrees C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions

  20. Practical reporting times for environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4{degrees}C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions.

  1. Compendium of Environmental Sustainability Indicator Collections: 2005 Environmental Sustainability Index (ESI)

    Data.gov (United States)

    National Aeronautics and Space Administration — The 2005 Environmental Sustainability Index (ESI) portion of the Compendium of Environmental Sustainability Indicators Collection contains 103 variables for 146...

  2. Compendium of Environmental Sustainability Indicator Collections: 2004 Environmental Vulnerability Index (EVI)

    Data.gov (United States)

    National Aeronautics and Space Administration — The 2004 Environmental Vulnerability Index (EVI) portion of the Compendium of Environmental Sustainability Indicator Collections contains 111 variables for 235...

  3. Radionuclides concentration in marine environmental samples along the coast of Vietnam

    International Nuclear Information System (INIS)

    Nguyen Trong Ngo; Nguyen Thanh Binh; Nguyen Van Phuc; Le Nhu Sieu; Truong Y; Mai Thi Huong; Nguyen Thi Linh; Nguyen Mong Sinh; Phan Son Hai; Le Ngoc Chung; Dang Duc Nhan; Nguyen Quang Long; Nguyen Hao Quang; Tran Tuyet Mai

    2009-01-01

    Studies on radioactivity inventories in environmental samples are necessary as they will serve as baseline data for assessing any environmental impact usage of nuclear-based activities. Approximately 700 data on 238 U, 232 Th, 226 Ra, 90 Sr, 137 Cs, 239,240 Pu activity concentrations in 150 samples i.e. sea water, sediment, fish, mollusc, crustaceans, oyster and weeds samples collected from 7 various locations in Vietnam (Hai Phong, Nghe An, Khanh Hoa, Ninh Thuan, Binh Thuan, Vung Tau, Tien Giang) throughout 1999-2008 are summarised and presented in this paper. Generally, the levels of artificial radionuclides in the studied marine environmental samples are lower as compared to other Asia-Pacific countries while naturally occurred radionuclides activity concentrations obtained were found to be in accordance with respective data from other studies within Pacific region. The radionuclides bioaccumulation factors studied in Red laver and oyster were mostly found to be high; therefore, further reinvestigation should be done for these biota that will be used as bio-fingerprint indicators in monitoring the marine environment from nuclear-based pollutions. The data set obtained from this study is available to the Asia-Pacific Marine Radioactivity Database. (author)

  4. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  5. Impact of sample size on principal component analysis ordination of an environmental data set: effects on eigenstructure

    Directory of Open Access Journals (Sweden)

    Shaukat S. Shahid

    2016-06-01

    Full Text Available In this study, we used bootstrap simulation of a real data set to investigate the impact of sample size (N = 20, 30, 40 and 50 on the eigenvalues and eigenvectors resulting from principal component analysis (PCA. For each sample size, 100 bootstrap samples were drawn from environmental data matrix pertaining to water quality variables (p = 22 of a small data set comprising of 55 samples (stations from where water samples were collected. Because in ecology and environmental sciences the data sets are invariably small owing to high cost of collection and analysis of samples, we restricted our study to relatively small sample sizes. We focused attention on comparison of first 6 eigenvectors and first 10 eigenvalues. Data sets were compared using agglomerative cluster analysis using Ward’s method that does not require any stringent distributional assumptions.

  6. Equipment for collecting samples of radioactive solutions

    International Nuclear Information System (INIS)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-01-01

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described

  7. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  8. Applications of liquid-phase microextraction in the sample preparation of environmental solid samples.

    Science.gov (United States)

    Prosen, Helena

    2014-05-23

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several innovative liquid-phase microextraction (LPME) techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME). Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  9. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    OpenAIRE

    Helena Prosen

    2014-01-01

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several...

  10. Analysis of the research sample collections of Uppsala biobank.

    Science.gov (United States)

    Engelmark, Malin T; Beskow, Anna H

    2014-10-01

    Uppsala Biobank is the joint and only biobank organization of the two principals, Uppsala University and Uppsala University Hospital. Biobanks are required to have updated registries on sample collection composition and management in order to fulfill legal regulations. We report here the results from the first comprehensive and overall analysis of the 131 research sample collections organized in the biobank. The results show that the median of the number of samples in the collections was 700 and that the number of samples varied from less than 500 to over one million. Blood samples, such as whole blood, serum, and plasma, were included in the vast majority, 84.0%, of the research sample collections. Also, as much as 95.5% of the newly collected samples within healthcare included blood samples, which further supports the concept that blood samples have fundamental importance for medical research. Tissue samples were also commonly used and occurred in 39.7% of the research sample collections, often combined with other types of samples. In total, 96.9% of the 131 sample collections included samples collected for healthcare, showing the importance of healthcare as a research infrastructure. Of the collections that had accessed existing samples from healthcare, as much as 96.3% included tissue samples from the Department of Pathology, which shows the importance of pathology samples as a resource for medical research. Analysis of different research areas shows that the most common of known public health diseases are covered. Collections that had generated the most publications, up to over 300, contained a large number of samples collected systematically and repeatedly over many years. More knowledge about existing biobank materials, together with public registries on sample collections, will support research collaborations, improve transparency, and bring us closer to the goals of biobanks, which is to save and prolong human lives and improve health and quality of life.

  11. Screening of IAEA environmental samples for fissile material content

    International Nuclear Information System (INIS)

    Hembree, Doyle M. Jr.; Carter, Joel A.; Devault, Gerald L.; Whitaker, J. Michael; Glasgow, David

    2001-01-01

    neutrons' because they are emitted after a brief decay period following irradiation. Counting these delayed neutrons provides a simple method for determining the total fissile content in the sample. Neutron activation analysis is a nuclear technique, which means that the chemical bonding environment of a fissile atom has no effect on the measurement process. Therefore, NAA is virtually immune to the 'matrix' effects that complicate other methods. As a result, environmental samples such as pine needles, water, soil, sediments, or swipes can all be rapidly analyzed with little or no sample preparation. All of the sources of error in the NAA-delayed neutron counting experiment are known and can be accounted for. In addition, the method is nondestructive and does not require the use of a blank measurement. The neutrons counted as a result of 239 Pu fission cannot be easily discriminated from those arising from 235 U. Therefore, the delayed neutron method proposed for sample screening will provide total fissile content; not the quantities of individual radionuclides. However, for most IAEA samples, it can be assumed that uranium is the predominant fissile material, and the method can be usefully employed for screening using this assumption (data collected from a large number of environmental samples supports this contention). The method is fast (∼5 minutes per sample), very sensitive (3-10 pg 235 U), and very accurate. An initial assessment of the NAA method was conducted using 35 swipe samples. The uranium results using thermal ionization mass spectrometry (TIMS) ranged from less than blank values to 332 ng/sample. The comparison of results between TIMS and NAA was quite favorable; the average percent difference between the two methods for the 35 samples was less than 5%. The accuracy, large dynamic range, speed, and low cost of the NAA-DN technique make the method an excellent choice for properly screening environmental samples. (author)

  12. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  13. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  14. Osmium in environmental samples from Northeast Sweden

    International Nuclear Information System (INIS)

    Rodushkin, Ilia; Engstroem, Emma; Soerlin, Dieke; Ponter, Christer; Baxter, Douglas C.

    2007-01-01

    Osmium (Os) concentrations and 187 Os/ 188 Os isotope abundance ratios are presented for sedimentary materials, soils, humus, plants, mushrooms, mosses and lichens collected in the vicinity of the town of Lulea, Northeast Sweden, the data for biological specimens being the first reported. Contributions from sampling and varying exposure time to the observed environmental variability were evaluated. Sedimentary materials (from both fresh and brackish water) are most elevated in radiogenic 187 Os, followed by inorganic soil horizons, mushrooms and humus. The Os isotopic compositions of plants, mosses and lichens are much less radiogenic, with mean 187 Os/ 188 Os lying within a relatively narrow 0.3-0.6 range. Significant temporal variations in Os concentrations and isotopic compositions of plant samples are attributed to integrative uptake of airborne Os with non-radiogenic composition. Measured Os concentrations in biological matrices increase in the order: small shrub leaves (blueberry and lingonberry) ≤ spruce needles ≤ mushrooms ≤ tree leaves ≤ pine needles 4 ) in the environment. Though the Os content of samples from Northeast Sweden does not differ significantly from matrix-matched international reference materials (not certified for Os) of abiotic origin, the estimates of gaseous OsO 4 concentrations are roughly an order of magnitude higher than have been reported for particle-bound Os in other studies. The pronounced spatial variations between relatively closely situated sites in mean 187 Os/ 188 Os ratios for samples of the same species (presumably with the same dominating uptake mechanism) point to the presence of different local Os sources. This study therefore demonstrates that emissions of Os from automobile catalytic converters are not the only source of contemporary environmental contamination

  15. 28 CFR 28.12 - Collection of DNA samples.

    Science.gov (United States)

    2010-07-01

    ... Homeland Security, collecting DNA samples from: (1) Aliens lawfully in, or being processed for lawful... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection...

  16. Sample collection: an overview of the Hydrogeochemical and Stream Sediment Reconnaissance Program

    International Nuclear Information System (INIS)

    Bolivar, S.L.

    1979-01-01

    A Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) for uranium is currently being conducted throughout the conterminous United States and Alaska. The HSSR is part of the National Uranium Resource Evaluation sponsored by the US Department of Energy. This ambitious geochemical reconnaissance program is conducted by four national laboratories: Los Alamos Scientific Laboratory, Lawrence Livermore Laboratory, Oak Ridge Gaseous Diffusion Plant, and Savannah River Laboratory. The program is based on an extensive review of world literature, reconnaissance work done in other countries, and pilot studies conducted by each laboratory. Sample-collection methods and sample density are determined to optimize the probability of detecting potential uranium mineralization. To achieve this aim, each laboratory has developed independent standardized field collection procedures that are designed for its section of the country. Field parameters such as pH, conductivity, climate, geography, and geology are recorded at each site. Most samples are collected at densities of one sample site per 10 to 23 km 2 . The HSSR program has helped to improve existing hydrogeochemical reconnaissance exploration techniques. In addition to providing industry with data that may help to identify potential uranium districts and to extend known uranium provinces, the HSSR also provides multi-element analytical data, which can be used in water quality, soil, sediment, environmental, and base-metal exploration studies

  17. Artificial radioactivity in the environmental samples as IAEA reference materials

    International Nuclear Information System (INIS)

    Salagean, M.; Pantelica, A.

    1998-01-01

    . Uncontaminated by nuclear activities: IAEA-327, Podsolic soil collected in 1990 from the Moscow region and considered uncontaminated by radionuclides of the Chernobyl accident or by other nuclear activities. The results obtained by our laboratory are in good agreement with the certified IAEA data. Generally, the concentration of the artificial radionuclides in the investigated samples is higher than that expected from the influence of global fallout in the intercomparison materials distributed before Chernobyl accident. Concerning the nature of these investigated IAEA reference materials, very high values for the concentration levels of cesium radionuclides especially in IAEA-373 (grass) and IAEA-375 (soil) samples collected in the vicinity of Chernobyl Power Station after the nuclear accident in 1986 were found. High levels of radioactivities for the artificial radionuclides were also determined in the samples collected in the neighbourhood of the nuclear installations, especially in marine sediment (IAEA-135). It is of interest to point out the high concentration of cesium radionuclides in IAEA-300 sediment collected in 1992 in the Baltic Sea in comparison with the IAEA-306 sediment collected also in the Baltic Sea in 1986. It seems to be an increase of the Baltic Sea artificial radioactivity by accumulation in time. Marine sediment constitutes an important component of marine ecosystem since it represents the final sink for any releases of wastes into the sea. These certified radioactive materials are very useful to all laboratories engaged in the radioactive pollution investigations on environmental samples. (authors)

  18. [Detection of Cryptospordium spp. in environmental water samples by FTA-PCR].

    Science.gov (United States)

    Zhang, Xiao-Ping; Zhu, Qian; He, Yan-Yan; Jiang, Li; Jiang, Shou-Fu

    2011-02-01

    To establish a FTA-polymeras chain reaction (FTA-PCR) method in detection of Cryptospordium spp. in different sources of water. The semi automated immunomagnetic separation (IMS) of Cryptospordium oocysts in environmental water samples was performed firstly, and then genomic DNA of Cryptospordium oocysts was extracted by FTA filters disk. Oligonucleotide primers were designed based on the DNA fragment of the 18 S rRNA gene from C. parvum. Plate DNA was amplified with primers in PCR. The control DNA samples from Toxoplasma gondii,Sarcocystis suihominis, Echinococcus granulosus, and Clonorchis sinensis were amplified simultaneously. All PCR products were detected by agar electrophoresis dyed with ethidium bromide. The 446 bp fragment of DNA was detected in all samples of C. parvum, C. andersoni, and C. baileyi, while it was not detected in control groups in laboratory. No positive samples were found from 10 samples collected from tape water in 5 districts of Shanghai City by FTA-PCR. Nine positive samples were detected totally from 70 different environmental water samples, there were 0 out of 15 samples from the source of tape water, 2 out of 25 from the Huangpu River, 5 out of 15 from rivers around the animal farmers, 1 out of 9 from output water of contaminating water treatment factory, 1 out of 6 from the out gate of living contaminating water. The 446 bp fragment was detected from all the amplified positive water samples. FTA-PCR is an efficient method for gene detection of Cryptospordium oocysts, which could be used in detection of environmental water samples. The contamination degree of Cryptospordium oocysts in the river water around animal farms is high.

  19. Hanford Environmental Monitoring Program schedule for samples, analyses, and measurements for calendar year 1985

    International Nuclear Information System (INIS)

    Blumer, P.J.; Price, K.R.; Eddy, P.A.; Carlile, J.M.V.

    1984-12-01

    This report provides the CY 1985 schedule of data collection for the routine Hanford Surface Environmental Monitoring and Ground-Water Monitoring Programs at the Hanford Site. The purpose is to evaluate and report the levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5484.1. The routine sampling schedule provided herein does not include samples scheduled to be collected during FY 1985 in support of special studies, special contractor support programs, or for quality control purposes. In addition, the routine program outlined in this schedule is subject to modification during the year in response to changes in site operations, program requirements, or unusual sample results

  20. Collecting Ground Samples for Balloon-Borne Instruments

    Science.gov (United States)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq

    2009-01-01

    A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

  1. Metagenomic analyses of novel viruses and plasmids from a cultured environmental sample of hyperthermophilic neutrophiles

    DEFF Research Database (Denmark)

    Garrett, Roger Antony; Prangishvili, David; Shah, Shiraz Ali

    2010-01-01

    Two novel viral genomes and four plasmids were assembled from an environmental sample collected from a hot spring at Yellowstone National Park, USA, and maintained anaerobically in a bioreactor at 85°C and pH 6. The double-stranded DNA viral genomes are linear (22.7 kb) and circular (17.7 kb...... respectively. Strategies are considered for assembling genomes of smaller genetic elements from complex environmental samples, and for establishing possible host identities on the basis of sequence similarity to host CRISPR immune systems....

  2. A whole-cell bioreporter assay for quantitative genotoxicity evaluation of environmental samples.

    Science.gov (United States)

    Jiang, Bo; Li, Guanghe; Xing, Yi; Zhang, Dayi; Jia, Jianli; Cui, Zhisong; Luan, Xiao; Tang, Hui

    2017-10-01

    Whole-cell bioreporters have emerged as promising tools for genotoxicity evaluation, due to their rapidity, cost-effectiveness, sensitivity and selectivity. In this study, a method for detecting genotoxicity in environmental samples was developed using the bioluminescent whole-cell bioreporter Escherichia coli recA::luxCDABE. To further test its performance in a real world scenario, the E. coli bioreporter was applied in two cases: i) soil samples collected from chromium(VI) contaminated sites; ii) crude oil contaminated seawater collected after the Jiaozhou Bay oil spill which occurred in 2013. The chromium(VI) contaminated soils were pretreated by water extraction, and directly exposed to the bioreporter in two phases: aqueous soil extraction (water phase) and soil supernatant (solid phase). The results indicated that both extractable and soil particle fixed chromium(VI) were bioavailable to the bioreporter, and the solid-phase contact bioreporter assay provided a more precise evaluation of soil genotoxicity. For crude oil contaminated seawater, the response of the bioreporter clearly illustrated the spatial and time change in genotoxicity surrounding the spill site, suggesting that the crude oil degradation process decreased the genotoxic risk to ecosystem. In addition, the performance of the bioreporter was simulated by a modified cross-regulation gene expression model, which quantitatively described the DNA damage response of the E. coli bioreporter. Accordingly, the bioluminescent response of the bioreporter was calculated as the mitomycin C equivalent, enabling quantitative comparison of genotoxicities between different environmental samples. This bioreporter assay provides a rapid and sensitive screening tool for direct genotoxicity assessment of environmental samples. Copyright © 2017. Published by Elsevier Ltd.

  3. Osmium in environmental samples from Northeast Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Rodushkin, Ilia [Division of Applied Geology, Lulea University of Technology, S-971 87 Lulea (Sweden); ALS Laboratory Group, ALS Analytica AB, Aurorum 10, S-977 75 Lulea (Sweden)], E-mail: ilia.rodushkin@alsglobal.com; Engstroem, Emma [Division of Applied Geology, Lulea University of Technology, S-971 87 Lulea (Sweden); Soerlin, Dieke; Ponter, Christer; Baxter, Douglas C. [ALS Laboratory Group, ALS Analytica AB, Aurorum 10, S-977 75 Lulea (Sweden)

    2007-11-01

    Osmium (Os) concentrations and {sup 187}Os/{sup 188}Os isotope abundance ratios are presented for sedimentary materials, soils, humus, plants, mushrooms, mosses and lichens collected in the vicinity of the town of Lulea, Northeast Sweden, the data for biological specimens being the first reported. Contributions from sampling and varying exposure time to the observed environmental variability were evaluated. Sedimentary materials (from both fresh and brackish water) are most elevated in radiogenic {sup 187}Os, followed by inorganic soil horizons, mushrooms and humus. The Os isotopic compositions of plants, mosses and lichens are much less radiogenic, with mean {sup 187}Os/{sup 188}Os lying within a relatively narrow 0.3-0.6 range. Significant temporal variations in Os concentrations and isotopic compositions of plant samples are attributed to integrative uptake of airborne Os with non-radiogenic composition. Measured Os concentrations in biological matrices increase in the order: small shrub leaves (blueberry and lingonberry) {<=} spruce needles {<=} mushrooms {<=} tree leaves {<=} pine needles < mosses << lichens. The concentrations found in three different species of plant were used to provide the first estimates of gaseous osmium tetroxide (OsO{sub 4}) in the environment. Though the Os content of samples from Northeast Sweden does not differ significantly from matrix-matched international reference materials (not certified for Os) of abiotic origin, the estimates of gaseous OsO{sub 4} concentrations are roughly an order of magnitude higher than have been reported for particle-bound Os in other studies. The pronounced spatial variations between relatively closely situated sites in mean {sup 187}Os/{sup 188}Os ratios for samples of the same species (presumably with the same dominating uptake mechanism) point to the presence of different local Os sources. This study therefore demonstrates that emissions of Os from automobile catalytic converters are not the only

  4. Modified electrode voltammetric sensors for trace metals in environmental samples

    Directory of Open Access Journals (Sweden)

    Brett Christopher M.A.

    2000-01-01

    Full Text Available Nafion-modified mercury thin film electrodes have been investigated for the analysis of trace metals in environmental samples of waters and effluent by batch injection analysis with square wave anodic stripping voltammetry. The method, involving injection over the detector electrode of untreated samples of volume of the order of 50 microlitres has fast response, blocking and fouling of the electrode is minimum as shown by studies with surface-active components. Comparison is made between glassy carbon substrate electrodes and carbon fibre microelectrode array substrates, the latter leading to a small sensitivity enhancement. Application to analysis of river water and industrial effluent for labile zinc, cadmium, lead and copper ions is demonstrated in collected samples and after acid digestion.

  5. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  6. Multielement fingerprinting for characterization: Earthworm samples from the environmental specimen bank of the FRG

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1988-01-01

    Earthworm samples (Lumbricidae) from three different sampling sites in the Federal Republic of Germany were collected for the German Environmental Specimen Bank (ESB). Subsamples of the cryohomogenized material from two annual samplings were analyzed by Instrumental Neutron Activation Analysis (INAA) and mean values are presented in the logarithmic fingerprint mode. The 'identical matrix reference material concept' of the ESB has been applied and proved to be of particular value for multielement determinations. (orig.)

  7. The Apollo lunar samples collection analysis and results

    CERN Document Server

    Young, Anthony

    2017-01-01

    This book focuses on the specific mission planning for lunar sample collection, the equipment used, and the analysis and findings concerning the samples at the Lunar Receiving Laboratory in Texas. Anthony Young documents the collection of Apollo samples for the first time for readers of all backgrounds, and includes interviews with many of those involved in planning and analyzing the samples. NASA contracted with the U.S. Geologic Survey to perform classroom and field training of the Apollo astronauts. NASA’s Geology Group within the Manned Spacecraft Center in Houston, Texas, helped to establish the goals of sample collection, as well as the design of sample collection tools, bags, and storage containers. In this book, detailed descriptions are given on the design of the lunar sampling tools, the Modular Experiment Transporter used on Apollo 14, and the specific areas of the Lunar Rover vehicle used for the Apollo 15, 16, and 17 missions, which carried the sampling tools, bags, and other related equipment ...

  8. Isotope dilution analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.; Korenova, Z.; Klas, J.; Klehr, E.H.

    1986-01-01

    Isotope dilution analysis has been used for the determination of several trace elements - especially metals - in a variety of environmental samples, including aerosols, water, soils, biological materials and geological materials. Variations of the basic concept include classical IDA, substoichiometric IDA, and more recently, sub-superequivalence IDA. Each variation has its advantages and limitations. A periodic chart has been used to identify those elements which have been measured in environmental samples using one or more of these methods. (author)

  9. Cesium-137 and natural radionuclides in soils from southern Brazil and soils and others environmental samples from Antarctic

    International Nuclear Information System (INIS)

    Schuch, L.A.

    1993-04-01

    This work presents a study of environmental artificial and natural radioactivity levels in soil samples from the Southern Brazil and in soils and other environmental samples form Antarctica. Artificial radioactivity was determined by measuring Cs-137 which is a 30.1 year half-life man-made radionuclide produced in the past by atmospheric tests of nuclear weapons. Natural radioactivity was determined by measuring some radionuclides belonging to Th-232 and U-238 natural radioactive families, and of K-40 concentrations. Several types of soils from Southern Brazil; and soil samples, marine sediments, lichens, mosses and algae collected at King George and other nearby islands (South Shetland Archipelago, Antarctica) were analyzed. A gamma-ray spectrometer was used to measure radioactivity levels of the collected samples and its overall characteristics are analyzed in this work. (author)

  10. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    Science.gov (United States)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  11. Salmonella isolated from individual reptiles and environmental samples from terraria in private households in Sweden.

    Science.gov (United States)

    Wikström, Veronica O; Fernström, Lise-Lotte; Melin, Lennart; Boqvist, Sofia

    2014-01-24

    This study investigates Salmonella spp. isolated from privately kept reptiles and from environmental samples such as bedding materials or water from the floor of the enclosures (terraria). It also compares isolation of Salmonella using Modified Semisolid Rappaport-Vassiliadis (MSRV) medium or selective enrichment in Rappaport-Vassiliadis-Soya (RVS) pepton broth. Cloacal swabs or swabs from the cloacal area were collected from 63 individual reptiles belonging to 14 households. All reptiles were from different terraria and from 62 of these, environmental samples were also collected. Sampling were done by the reptile owners according to written instructions and sent by mail immediately after sampling. All but three samples were analyzed within 24 h after collection. Colonies suspected for Salmonella were tested for agglutination and serotyped using the White-Kauffmann-Le Minor scheme. The relative sensitivity (se) and specificity (sp) for MSRV compared with RVS, and the agreement coefficient kappa (κ) were calculated. Salmonella was isolated from 50/63 (80%) terraria, either from the reptiles (31/63; 49%) or from bedding material (39/62; 63%). The most common subspecies was Salmonella enterica subspecies enterica followed by S. enterica subspecies diarizonae. In reptiles, the most common S. enterica subspecies enterica serovars were Java (n = 4) and Fluntern (n = 4), compared with the serovars Tennessee (n = 10) and Fluntern (n = 10) in the environmental samples. The exact same set of Salmonella subspecies and serovars were not isolated from the individual reptiles and the environmental samples from any of the households. Isolation using MSRV yielded more Salmonella isolates 61/113 (54%) than enrichment in RVS 57/125 (46%). The se was 97.9% (95% Confidence Interval 93.9-100), the sp 78.5% (95% CI 68.5-88.5) and the κ 0.74, indicating substantial agreement between the tests. Salmonella can be expected to be present in environments where reptiles are

  12. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    Energy Technology Data Exchange (ETDEWEB)

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear

  13. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1993-03-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others

  14. DOE methods for evaluating environmental and waste management samples.

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K [eds.; Pacific Northwest Lab., Richland, WA (United States)

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  15. The development of a Martian atmospheric Sample collection canister

    Science.gov (United States)

    Kulczycki, E.; Galey, C.; Kennedy, B.; Budney, C.; Bame, D.; Van Schilfgaarde, R.; Aisen, N.; Townsend, J.; Younse, P.; Piacentine, J.

    The collection of an atmospheric sample from Mars would provide significant insight to the understanding of the elemental composition and sub-surface out-gassing rates of noble gases. A team of engineers at the Jet Propulsion Laboratory (JPL), California Institute of Technology have developed an atmospheric sample collection canister for Martian application. The engineering strategy has two basic elements: first, to collect two separately sealed 50 cubic centimeter unpressurized atmospheric samples with minimal sensing and actuation in a self contained pressure vessel; and second, to package this atmospheric sample canister in such a way that it can be easily integrated into the orbiting sample capsule for collection and return to Earth. Sample collection and integrity are demonstrated by emulating the atmospheric collection portion of the Mars Sample Return mission on a compressed timeline. The test results achieved by varying the pressure inside of a thermal vacuum chamber while opening and closing the valve on the sample canister at Mars ambient pressure. A commercial off-the-shelf medical grade micro-valve is utilized in the first iteration of this design to enable rapid testing of the system. The valve has been independently leak tested at JPL to quantify and separate the leak rates associated with the canister. The results are factored in to an overall system design that quantifies mass, power, and sensing requirements for a Martian atmospheric Sample Collection (MASC) canister as outlined in the Mars Sample Return mission profile. Qualitative results include the selection of materials to minimize sample contamination, preliminary science requirements, priorities in sample composition, flight valve selection criteria, a storyboard from sample collection to loading in the orbiting sample capsule, and contributions to maintaining “ Earth” clean exterior surfaces on the orbiting sample capsule.

  16. Prospects for the introduction of Wide Area Monitoring Using Environmental Sampling

    International Nuclear Information System (INIS)

    Wogman, N.A.

    2013-01-01

    Nuclear proliferation signatures released to the environment must be collected and distinguished from primordial and man-made backgrounds in soils, sediments, air, and surface and underground water. The delay time between the nuclear proliferation emissions and the date of the Wide-Area Environmental Sampling (WAES) analysis will determine which radionuclides would be analyzed based upon their half-lives. Various sampling and analysis technologies have been considered here for application to a WAES. Sampling procedures and equipment discussed are aimed at aquatic, airborne particulate, gas, vegetation, sediment and/or soil, and fauna media. Specific procedures must be selected based upon the application scenario; for example, sampling in the northern latitudes under freezing conditions, sampling at the equator under tropical rain-forest conditions, sampling in the mid-latitudes under desert conditions, and sampling in the marine environment require different equipment and procedures. The paper is followed by the slides of the presentation

  17. The U.S. Geological Survey Geologic Collections Management System (GCMS)—A master catalog and collections management plan for U.S. Geological Survey geologic samples and sample collections

    Science.gov (United States)

    ,

    2015-01-01

    The U.S. Geological Survey (USGS) is widely recognized in the earth science community as possessing extensive collections of earth materials collected by research personnel over the course of its history. In 2006, a Geologic Collections Inventory was conducted within the USGS Geology Discipline to determine the extent and nature of its sample collections, and in 2008, a working group was convened by the USGS National Geologic and Geophysical Data Preservation Program to examine ways in which these collections could be coordinated, cataloged, and made available to researchers both inside and outside the USGS. The charge to this working group was to evaluate the proposition of creating a Geologic Collections Management System (GCMS), a centralized database that would (1) identify all existing USGS geologic collections, regardless of size, (2) create a virtual link among the collections, and (3) provide a way for scientists and other researchers to obtain access to the samples and data in which they are interested. Additionally, the group was instructed to develop criteria for evaluating current collections and to establish an operating plan and set of standard practices for handling, identifying, and managing future sample collections. Policies and procedures promoted by the GCMS would be based on extant best practices established by the National Science Foundation and the Smithsonian Institution. The resulting report—USGS Circular 1410, “The U.S. Geological Survey Geologic Collections Management System (GCMS): A Master Catalog and Collections Management Plan for U.S. Geological Survey Geologic Samples and Sample Collections”—has been developed for sample repositories to be a guide to establishing common practices in the collection, retention, and disposal of geologic research materials throughout the USGS.

  18. Dehalococcoides as a Potential Biomarker Evidence for Uncharacterized Organohalides in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Qihong Lu

    2017-09-01

    Full Text Available The massive production and improper disposal of organohalides resulted in worldwide contamination in soil and water. However, their environmental survey based on chromatographic methods was hindered by challenges in testing the extremely wide variety of organohalides. Dehalococcoides as obligate organohalide-respiring bacteria exclusively use organohalides as electron acceptors to support their growth, of which the presence could be coupled with organohalides and, therefore, could be employed as a biomarker of the organohalide pollution. In this study, Dehalococcoides was screened in various samples of bioreactors and subsurface environments, showing the wide distribution of Dehalococcoides in sludge and sediment. Further laboratory cultivation confirmed the dechlorination activities of those Dehalococcoides. Among those samples, Dehalococcoides accounting for 1.8% of the total microbial community was found in an anaerobic granular sludge sample collected from a full-scale bioreactor treating petroleum wastewater. Experimental evidence suggested that the influent wastewater in the bioreactor contained bromomethane which support the growth of Dehalococcoides. This study demonstrated that Dehalococcoides could be employed as a promising biomarker to test the present of organohalides in wastestreams or other environmental samples.

  19. Ash contents of foodstuff samples in environmental radioactivity analysis

    International Nuclear Information System (INIS)

    Oikawa, Shinji; Ohta, Hiroshi; Hayano, Kazuhiko; Nonaka, Nobuhiro

    2004-01-01

    Statistical data of the ash content in various environmental samples obtained from an environmental radioactivity survey project commissioned by the Japanese government of Science and Technology Agency (at present Ministry of Education, Culture, Sports, Sciences and Technology) during the past 10 years are expressed for establishing a standard of ash content in environmental samples based on radioactivity analysis. The ash content for some kinds of environmental samples such as dietary food, milk, Japanese radish, spinach, fish, green tea and potato was reviewed in the light of statistical and stochastic viewpoints. For all of the samples reviewed in this paper, the coefficient of variation varied from 4.7% for milk to 36.3% for cabbage. Dietary food and milk samples were reviewed more than 1900 and 1400 samples, respectively. Especially, ash content of dietary food depended mainly on the dietary culture reflected on the period. However it showed an almost invariant distribution within 18.7% of coefficient of variation during the past 10 years. Pretreatment of environmental samples especially ashing processes are important from the viewpoint on environmental radioactivity analysis, which is one of the especial fields in analytical chemistry. Statistical reviewed data obtained in this paper may be useful for sample preparation. (author)

  20. A comparison of some radionuclide contents in environmental samples

    International Nuclear Information System (INIS)

    Shiraishi, Kunio; Muramatsu, Yasuyuki; Nakajima, Toshiyuki; Yamamoto, Masayoshi; Los, I.P.; Kamarikov, I.Yu.; Buzinny, M.G.

    1992-01-01

    Global contamination by radionuclides was likely induced through the Chernobyl nuclear accident in 1986. Environmental samples such as fish, milk, total diet samples etc., collected in Kiev, in the vicinity of Chernobyl, and Mito city, Japan, were analyzed for six selected radionuclides. After samples were dry-ashed, radioactivities of Cs-137, Cs-134, K-40, Co-60, and Mn-54 were determined by gamma-ray spectroscopy with a germanium detector. Strontium-90 was determined by low-background beta-spectrometry after chemical separations by fuming nitric acid. Concentrations of radioactivities in the Kiev samples, in the vicinity of the Chernobyl, are shown below. For comparison, values obtained in Japan, including literature values, are shown in parentheses. Radioactivities in airborne dust were: Sr-90, 63 mBq/m 3 (0.001-0.1); Cs-137, 26 mBg/m 3 (0.001-1); Cs-134, 4 mBq/m 3 ; Co-60, 4 mBq/m 3 ; Mn-54, 2 mBq/m 3 . Radioactivities of milk were as follows; Sr-90, 0.25-1.2 Bq/liter (0.01-0.1); Cs-137, 6-77 Bq/liter (0.01-1); Cs-134, 2-8 Bq/liter. Radioactivities of Sr-90 and Cs-137 for fish (carp), were found to be 3-75 Bq/kg-fresh (0.76-0.98) and 46-2130 Bq/kg-fresh (<0.8), respectively. It was observed that the daily intake of Sr-90 and Cs-137 were 0.25 Bq (0.1) and 0.43 Bq (0.1) per person, respectively. Due to the small number of samples analyzed it is premature to draw a firm conclusion from this study. However, the levels of radionuclides in environmental samples were found to differ between Kiev and Mito with wide ranges depending on the samples. (author)

  1. Biopolymers for sample collection, protection, and preservation.

    Science.gov (United States)

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  2. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  3. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  4. Speciation of Cr(VI) in environmental samples in the vicinity of the ferrochrome smelter.

    Science.gov (United States)

    Sedumedi, Hilda N; Mandiwana, Khakhathi L; Ngobeni, Prince; Panichev, Nikolay

    2009-12-30

    The impact of ferrochrome smelter on the contamination of its environment with toxic hexavalent chromium, Cr(VI), was assessed by analyzing smelter dusts, soil, grass and tree barks. For the separation of Cr(VI) from Cr(III), solid samples were treated with 0.1M Na(2)CO(3) and filtered through hydrophilic PDVF 0.45 microm filter prior to the determination of Cr(VI) by electrothermal atomic absorption spectrometry (ET-AAS). Ferrochrome smelter dust was found to contain significant levels of Cr(VI), viz. 43.5 microg g(-1) (cyclone dust), 2710 microg g(-1) (fine dust), and 7800 microg g(-1) (slimes dust) which exceeded the maximum acceptable risk concentration (20 microg g(-1)). The concentration of Cr(VI) in environmental samples of grass (3.4+/-0.2), soil (7.7+/-0.2), and tree bark (11.8+/-1.2) collected in the vicinity of the chrome smelter were higher as compared with the same kind of samples collected from uncontaminated area. The results of the investigation show that ferrochrome smelter is a source of environmental pollution with contamination factors of Cr(VI) ranging between 10 and 50.

  5. Speciation of Cr(VI) in environmental samples in the vicinity of the ferrochrome smelter

    International Nuclear Information System (INIS)

    Sedumedi, Hilda N.; Mandiwana, Khakhathi L.; Ngobeni, Prince; Panichev, Nikolay

    2009-01-01

    The impact of ferrochrome smelter on the contamination of its environment with toxic hexavalent chromium, Cr(VI), was assessed by analyzing smelter dusts, soil, grass and tree barks. For the separation of Cr(VI) from Cr(III), solid samples were treated with 0.1 M Na 2 CO 3 and filtered through hydrophilic PDVF 0.45 μm filter prior to the determination of Cr(VI) by electrothermal atomic absorption spectrometry (ET-AAS). Ferrochrome smelter dust was found to contain significant levels of Cr(VI), viz. 43.5 μg g -1 (cyclone dust), 2710 μg g -1 (fine dust), and 7800 μg g -1 (slimes dust) which exceeded the maximum acceptable risk concentration (20 μg g -1 ). The concentration of Cr(VI) in environmental samples of grass (3.4 ± 0.2), soil (7.7 ± 0.2), and tree bark (11.8 ± 1.2) collected in the vicinity of the chrome smelter were higher as compared with the same kind of samples collected from uncontaminated area. The results of the investigation show that ferrochrome smelter is a source of environmental pollution with contamination factors of Cr(VI) ranging between 10 and 50.

  6. The integrated performance evaluation program quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    EM's (DOE's Environmental Restoration and Waste Management) Integrated Performance Evaluation Program (IPEP) has the purpose of integrating information from existing PE programs with expanded QA activities to develop information about the quality of radiological, mixed waste, and hazardous environmental sample analyses provided by all laboratories supporting EM programs. The guidance addresses the goals of identifying specific PE sample programs and contacts, identifying specific requirements for participation in DOE's internal and external (regulatory) programs, identifying key issues relating to application and interpretation of PE materials for EM headquarters and field office managers, and providing technical guidance covering PE materials for site-specific activities. (PE) Performance Evaluation materials or samples are necessary for the quality assurance/control programs covering environmental data collection

  7. Hanford Environmental Information System (HEIS). Volume 7: Sample and Data Tracking subject area

    International Nuclear Information System (INIS)

    1994-06-01

    The Hanford Environmental Information System (HEIS) Sample and Data Tracking subject area allows insertion of tracking information into a central repository where the data is immediately available for viewing. For example, a technical coordinator is able to view the current status of a particular sampling effort, from sample collection to data package validation dates. Four major types of data comprise the Sample and Data Tracking subject area: data about the mechanisms that groups a set of samples for a particular sampling effort; data about how constituents are grouped and assigned to a sample; data about when, where, and how samples are sent to a laboratory for analysis; and data bout the status of a sample's constituent analysis requirements, i.e., whether the analysis results have been returned from the laboratory

  8. New Zealand guidelines for the collection of groundwater samples for chemical and isotopic analyses

    International Nuclear Information System (INIS)

    Rosen, M.R.; Cameron, S.G.; Reeves, R.R.; Taylor, C.B.

    1999-01-01

    Chemical and isotopic analyses of groundwater are important tools for differentiating between the natural composition and human-induced contaminants of groundwater. A comprehensive suite of inorganic water chemical analyses is necessary to characterise waters. The geology of New Zealand is diverse, so it is impractical to characterise a ''typical'' groundwater chemical composition. Each aquifer system should be evaluated individually because the major dissolved species contain useful information about the pathways of water through the soil zone into the aquifer. Analyses of major ions such as chloride, nitrate, potassium and sulphate often give indication of septic systems and agricultural contamination. The minor ions, while most are not considered contaminants, are often indicators of human activity. Iron and manganese are good indicators of Eh potential, which is an important control on the mobility of many heavy metals. The inexpensive inorganic chemical analytical suite should be used as a guide to advisability of more expensive contaminant testing. The purpose of this manual is to provide consistent groundwater sampling guidelines for use throughout New Zealand. Sinton's (1998) guide to groundwater sampling techniques provided a sound basis for the accurate collection of groundwater samples. However Sinton did not address sampling materials and techniques for the collection of samples for ultra trace component analysis or the collection of environmental isotope samples. These important aspects of groundwater sampling have been included in this updated manual. (author). 30 refs., 12 figs., 5 tabs., 1 appendix

  9. Concordance analysis of methylation biomarkers detection in self-collected and physician-collected samples in cervical neoplasm

    International Nuclear Information System (INIS)

    Chang, Cheng-Chang; Huang, Rui-Lan; Liao, Yu-Ping; Su, Po-Hsuan; Hsu, Yaw-Wen; Wang, Hui-Chen; Tien, Chau-Yang; Yu, Mu-Hsien; Lin, Ya-Wen; Lai, Hung-Cheng

    2015-01-01

    Non-attendance at gynecological clinics is a major limitation of cervical cancer screening and self-collection of samples may improve this situation. Although HPV testing of self-collected vaginal samples is acceptable, the specificity is inadequate. The current focus is increasing self-collection of vaginal samples to minimize clinic visits. In this study, we analyzed the concordance and clinical performance of DNA methylation biomarker (PAX1, SOX1, and ZNF582) detection in self-collected vaginal samples and physician-collected cervical samples for the identification of cervical neoplasm. We enrolled 136 cases with paired methylation data identified from abnormal Pap smears (n = 126) and normal controls (n = 10) regardless of HPV status at gynecological clinics. The study group comprised 37 cervical intraepithelial neoplasm I (CIN1), 23 cervical intraepithelial neoplasm II (CIN2), 16 cervical intraepithelial neoplasm III (CIN3), 30 carcinoma in situ (CIS), 13 squamous cell carcinomas (SCCs) and seven adenocarcinomas (ACs)/adenosquamous carcinomas (ASCs). PAX1, SOX1 and ZNF582 methylation in study samples was assessed by real-time quantitative methylation-specific polymerase chain reaction analysis. We generated methylation index cutoff values for the detection of CIN3+ in physician-collected cervical samples for analysis of the self-collected group. Concordance between the physician-collected and self-collected groups was evaluated by Cohen’s Kappa. Sensitivity, specificity and area under curve (AUC) were calculated for detection of CIN3+ lesions. Finally, we produced an optimal cutoff value with the best sensitivity from the self-collected groups. We generated a methylation index cutoff value from physician-collected samples for detection of CIN3+. There were no significant differences in sensitivity, specificity of PAX1, SOX1 and ZNF582 between the self-collected and physician-collected groups. The methylation status of all three genes in the normal control

  10. New trends in sample preparation techniques for environmental analysis.

    Science.gov (United States)

    Ribeiro, Cláudia; Ribeiro, Ana Rita; Maia, Alexandra S; Gonçalves, Virgínia M F; Tiritan, Maria Elizabeth

    2014-01-01

    Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).

  11. Use of aspiration method for collecting brain samples for rabies diagnosis in small wild animals.

    Science.gov (United States)

    Iamamoto, K; Quadros, J; Queiroz, L H

    2011-02-01

    In developing countries such as Brazil, where canine rabies is still a considerable problem, samples from wildlife species are infrequently collected and submitted for screening for rabies. A collaborative study was established involving environmental biologists and veterinarians for rabies epidemiological research in a specific ecological area located at the Sao Paulo State, Brazil. The wild animals' brains are required to be collected without skull damage because the skull's measurements are important in the identification of the captured animal species. For this purpose, samples from bats and small mammals were collected using an aspiration method by inserting a plastic pipette into the brain through the magnum foramen. While there is a progressive increase in the use of the plastic pipette technique in various studies undertaken, it is also appreciated that this method could foster collaborative research between wildlife scientists and rabies epidemiologists thus improving rabies surveillance. © 2009 Blackwell Verlag GmbH.

  12. Radiochemical verification and validation in the environmental data collection process

    International Nuclear Information System (INIS)

    Rosano-Reece, D.; Bottrell, D.; Bath, R.J.

    1994-01-01

    A credible and cost effective environmental data collection process should produce analytical data which meets regulatory and program specific requirements. Analytical data, which support the sampling and analysis activities at hazardous waste sites, undergo verification and independent validation before the data are submitted to regulators. Understanding the difference between verification and validation and their respective roles in the sampling and analysis process is critical to the effectiveness of a program. Verification is deciding whether the measurement data obtained are what was requested. The verification process determines whether all the requirements were met. Validation is more complicated than verification. It attempts to assess the impacts on data use, especially when requirements are not met. Validation becomes part of the decision-making process. Radiochemical data consists of a sample result with an associated error. Therefore, radiochemical validation is different and more quantitative than is currently possible for the validation of hazardous chemical data. Radiochemical data include both results and uncertainty that can be statistically compared to identify significance of differences in a more technically defensible manner. Radiochemical validation makes decisions about analyte identification, detection, and uncertainty for a batch of data. The process focuses on the variability of the data in the context of the decision to be made. The objectives of this paper are to present radiochemical verification and validation for environmental data and to distinguish the differences between the two operations

  13. Environmental-benefit analysis of two urban waste collection systems.

    Science.gov (United States)

    Aranda Usón, Alfonso; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-10-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO2 emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO2-eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. Copyright © 2013 Elsevier B.V. All

  14. Speciation of Cr(VI) in environmental samples in the vicinity of the ferrochrome smelter

    Energy Technology Data Exchange (ETDEWEB)

    Sedumedi, Hilda N. [Department of Chemistry, Tshwane University of Technology, P.O. Box 56208, Arcadia, 0007, Pretoria (South Africa); Mandiwana, Khakhathi L., E-mail: MandiwanaKL@tut.ac.za [Department of Chemistry, Tshwane University of Technology, P.O. Box 56208, Arcadia, 0007, Pretoria (South Africa); Ngobeni, Prince; Panichev, Nikolay [Department of Chemistry, Tshwane University of Technology, P.O. Box 56208, Arcadia, 0007, Pretoria (South Africa)

    2009-12-30

    The impact of ferrochrome smelter on the contamination of its environment with toxic hexavalent chromium, Cr(VI), was assessed by analyzing smelter dusts, soil, grass and tree barks. For the separation of Cr(VI) from Cr(III), solid samples were treated with 0.1 M Na{sub 2}CO{sub 3} and filtered through hydrophilic PDVF 0.45 {mu}m filter prior to the determination of Cr(VI) by electrothermal atomic absorption spectrometry (ET-AAS). Ferrochrome smelter dust was found to contain significant levels of Cr(VI), viz. 43.5 {mu}g g{sup -1} (cyclone dust), 2710 {mu}g g{sup -1} (fine dust), and 7800 {mu}g g{sup -1} (slimes dust) which exceeded the maximum acceptable risk concentration (20 {mu}g g{sup -1}). The concentration of Cr(VI) in environmental samples of grass (3.4 {+-} 0.2), soil (7.7 {+-} 0.2), and tree bark (11.8 {+-} 1.2) collected in the vicinity of the chrome smelter were higher as compared with the same kind of samples collected from uncontaminated area. The results of the investigation show that ferrochrome smelter is a source of environmental pollution with contamination factors of Cr(VI) ranging between 10 and 50.

  15. Determination of carbon-14 environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia Sanz, M.R.; Gomez, V.; Heras, M.C.; Beltran, M.A.

    1990-01-01

    A method for the determination of Carbon-14 ( 14 CO 2 ) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO 2 ) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discused and compared. The method of collection of atmospheric samples is also described. (Author)

  16. Planning for the Collection and Analysis of Samples of Martian Granular Materials Potentially to be Returned by Mars Sample Return

    Science.gov (United States)

    Carrier, B. L.; Beaty, D. W.

    2017-12-01

    NASA's Mars 2020 rover is scheduled to land on Mars in 2021 and will be equipped with a sampling system capable of collecting rock cores, as well as a specialized drill bit for collecting unconsolidated granular material. A key mission objective is to collect a set of samples that have enough scientific merit to justify returning to Earth. In the case of granular materials, we would like to catalyze community discussion on what we would do with these samples if they arrived in our laboratories, as input to decision-making related to sampling the regolith. Numerous scientific objectives have been identified which could be achieved or significantly advanced via the analysis of martian rocks, "regolith," and gas samples. The term "regolith" has more than one definition, including one that is general and one that is much more specific. For the purpose of this analysis we use the term "granular materials" to encompass the most general meaning and restrict "regolith" to a subset of that. Our working taxonomy includes the following: 1) globally sourced airfall dust (dust); 2) saltation-sized particles (sand); 3) locally sourced decomposed rock (regolith); 4) crater ejecta (ejecta); and, 5) other. Analysis of martian granular materials could serve to advance our understanding areas including habitability and astrobiology, surface-atmosphere interactions, chemistry, mineralogy, geology and environmental processes. Results of these analyses would also provide input into planning for future human exploration of Mars, elucidating possible health and mechanical hazards caused by the martian surface material, as well as providing valuable information regarding available resources for ISRU and civil engineering purposes. Results would also be relevant to matters of planetary protection and ground-truthing orbital observations. We will present a preliminary analysis of the following, in order to generate community discussion and feedback on all issues relating to: What are the

  17. Free water {sup 3}H concentration in diet samples collected during 1969-88 in Akita, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Hisamatsu, S. [Institute for Environmental Sciences, Rokkasho, Aomori (Japan); Inoue, Y.; Miyamoto, K. [National Inst. of Radiological Sciences, Chiba (Japan); Takizawa, Y. [National Institute for Minamata Disease, Minamata, Kumamoto (Japan)

    2000-05-01

    Fallout {sup 3}H concentrations in diet samples collected during 1969-88 in Akita Prefecture are reported in this paper. Since {sup 3}H is a potential nuclear fuel for fusion reactors in future, its environmental behavior is important for dose assessment of released {sup 3}H from the plants. Tritium in foods is classified into two types; free water {sup 3}H (FWT) and organically-bound {sup 3}H (OBT). The FWT is practically separated by means of freeze-drying, while the OBT is measured with water sample collected by combustion of dried sample. The OBT concentrations in foods and human tissue samples were reported for {sup 3}H originating from nuclear weapon fallout. We already published {sup 3}H concentrations in diet samples collected in Akita City during 1985-88. Although results for the samples collected in U.S.A. and European countries in the 1970s showed higher specific activity of OBT than FWT, our recent results in Japan indicate almost the same specific activity between them. Since the measurements for the samples in 1960s and 1970s are important to understand the long-term movement of {sup 3}H in the environment, we have searched old diet samples. Recently, diet samples collected in Akita Prefecture during 1969-80 were found and obtained for {sup 3}H analysis. The samples were originally gathered for nutrition survey programs and consisted of duplicate diet samples for 1 day from 10-30 persons. Food samples excluding boiled rice which is the staple food was homogenized by electric mixers after adding tap water. Then, the food and the boiled rice samples were stored in a refrigerator at -20degC. Free water in the samples was collected with lyophilization, then {sup 3}H in the water sample was measured after purification with low-level liquid scintillation counters. The free water {sup 3}H concentrations were measured for 57 diet samples (dish excluding boiled rice) and 17 boiled rice samples. The free water {sup 3}H concentrations in diet and rice samples

  18. Gamma spectrometric analyses of environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Faruq, M.U.; Parveen, N.; Ahmed, B.; Aziz, A.

    1979-01-01

    Gamma spectrometric analyses of air and other environmental samples from PINSTECH were carried out. Air particulate samples were analyzed by a Ge(Li) detector on a computer-based multichannel analyzer. Other environmental samples were analyzed by a Na(T1) scintillation detector spectrometer and a multichannel analyzer with manual analysis. Concentration of radionuclides in the media was determined and the sources of their production were identified. Age of the fall out was estimated from the ratios of the fission products. (authors)

  19. TECHNIQUES WITH POTENTIAL FOR HANDLING ENVIRONMENTAL SAMPLES IN CAPILLARY ELECTROPHORESIS

    Science.gov (United States)

    An assessment of the methods for handling environmental samples prior to capillary electrophoresis (CE) is presented for both aqueous and solid matrices. Sample handling in environmental analyses is the subject of ongoing research at the Environmental Protection Agency's National...

  20. Collection and analysis of environmental radiation data using a desktop computer

    International Nuclear Information System (INIS)

    Gogolak, C.V.

    1982-04-01

    A portable instrumentation sytem using a Hewlett-Packard HP-9825 desktop computer for the collection and analysis of environmental radiation data is described. Procedures for the transmission of data between the HP-9825 and various nuclear counters are given together with a description of the necessary hardware and software. Complete programs for the analysis of Ge(Li) and NaI(Tl) gamma-ray spectra, high pressure ionization chamber monitor data, 86 Kr monitor data and air filter sample alpha particle activity measurements are presented. Some utility programs, intended to increase system flexibility, are included

  1. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  2. Environmental-benefit analysis of two urban waste collection systems

    International Nuclear Information System (INIS)

    Aranda Usón, Alfonso; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-01-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO 2 emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO 2 -eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. - Highlights: • A comprehensive

  3. Environmental-benefit analysis of two urban waste collection systems

    Energy Technology Data Exchange (ETDEWEB)

    Aranda Usón, Alfonso, E-mail: alaranda@unizar.es; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-10-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO{sub 2} emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO{sub 2}-eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. - Highlights: • A

  4. Natural Radioactivity Pattern of Surabaya Water Environmental Samples

    International Nuclear Information System (INIS)

    Rosidi; Agus Taftazani

    2007-01-01

    The gross β radioactivity and natural radionuclide of Surabaya environmental samples pattern have been evaluated. The environmental samples were chosen randomly at 12 locations. The environment samples were water (fresh, estuary and coastal), sediment, eichhornia crassipes (Mart) Solms, Mangrove (Rhizophora stylosa), (Moolgarda delicatus) fish and (Johnius (Johnieops) borneensis) (Sharpnose hammer croaker) fish. The water sample was evaporated; the sediment sample was dried and ground; the biotic samples was burnt at the temperature 500 °C ; The gross β measurement using GM detector and the radionuclides has been identified by γ spectrometer. From the investigation results could be concluded that the natural radioactivity of environmental samples was very low. gross-β of water samples were lower than the threshold value of local government regulation of Surabaya no: 2 year 2004 (1 Bq/L). The distribution of gross-β activity of eichhornia crassipes (Mart) Solms was higher than the other biotic, water and sediment samples as well as the accumulation of radionuclides in the water organism was taken place. The result of identification using γ spectrometer has detected 7 of radionuclides, i.e 210 Pb, 212 Pb, 214 Pb, 208 Tl, 214 Bi, 228 Ac, and 40 K in all sample. The distribution factor of sediment F D was less than bioaccumulation factor of biotic F B and it indicates that there the radionuclide accumulation migration follows the pattern of water - sediment - biotic sample. (author)

  5. Water sample-collection and distribution system

    Science.gov (United States)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  6. Characterization Of Core Sample Collected From The Saltstone Disposal Facility

    International Nuclear Information System (INIS)

    Cozzi, A.; Duncan, A.

    2010-01-01

    During the month of September 2008, grout core samples were collected from the Saltstone Disposal Facility, Vault 4, cell E. This grout was placed during processing campaigns in December 2007 from Deliquification, Dissolution and Adjustment Batch 2 salt solution. The 4QCY07 Waste Acceptance Criteria sample collected on 11/16/07 represents the salt solution in the core samples. Core samples were retrieved to initiate the historical database of properties of emplaced Saltstone and to demonstrate the correlation between field collected and laboratory prepared samples. Three samples were collected from three different locations. Samples were collected using a two-inch diameter concrete coring bit. In April 2009, the core samples were removed from the evacuated sample container, inspected, transferred to PVC containers, and backfilled with nitrogen. Samples furthest from the wall were the most intact cylindrically shaped cored samples. The shade of the core samples darkened as the depth of coring increased. Based on the visual inspection, sample 3-3 was selected for all subsequent analysis. The density and porosity of the Vault 4 core sample, 1.90 g/cm 3 and 59.90% respectively, were comparable to values achieved for laboratory prepared samples. X-ray diffraction analysis identified phases consistent with the expectations for hydrated Saltstone. Microscopic analysis revealed morphology features characteristic of cementitious materials with fly ash and calcium silicate hydrate gel. When taken together, the results of the density, porosity, x-ray diffraction analysis and microscopic analysis support the conclusion that the Vault 4, Cell E core sample is representative of the expected waste form.

  7. Assessing human error during collecting a hydrocarbon sample of ...

    African Journals Online (AJOL)

    This paper reports the assessment method of the hydrocarbon sample collection standard operation procedure (SOP) using THERP. The Performance Shaping Factors (PSF) from THERP analyzed and assessed the human errors during collecting a hydrocarbon sample of a petrochemical refinery plant. Twenty-two ...

  8. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  9. Detection of the actinides and cesium from environmental samples

    Science.gov (United States)

    Snow, Mathew Spencer

    Detection of the actinides and cesium in the environment is important for a variety of applications ranging from environmental remediation to safeguards and nuclear forensics. The utilization of multiple different elemental concentrations and isotopic ratios together can significantly improve the ability to attribute contamination to a unique source term and/or generation process; however, the utilization of multiple elemental "signatures" together from environmental samples requires knowledge of the impact of chemical fractionation for various elements under a variety of environmental conditions (including predominantly aqueous versus arid conditions). The research reported in this dissertation focuses on three major areas: 1. Improving the understanding of actinide-mineral interactions at ultra-low concentrations. Chapter 2 reports a batch sorption and modeling study of Np(V) sorption to the mineral goethite from attomolar to micromolar concentrations. 2. Improving the detection capabilities for Thermal Ionization Mass Spectrometry (TIMS) analyses of ultra-trace cesium from environmental samples. Chapter 4 reports a new method which significantly improves the chemical yields, purification, sample processing time, and ultimately, the detection limits for TIMS analyses of femtogram quantities of cesium from a variety of environmental sample matrices. 3. Demonstrating how actinide and cesium concentrations and isotopic ratios from environmental samples can be utilized together to determine a wealth of information including environmental transport mechanisms (e.g. aqueous versus arid transport) and information on the processes which generated the original material. Chapters1, 3 and 5 demonstrate these principles using Pu, Am, Np, and Cs concentrations and isotopic ratios from contaminated soils taken near the Subsurface Disposal Area (SDA) of Idaho National Laboratory (INL) (a low level radioactive waste disposal site in southeastern Idaho).

  10. Automated high-volume aerosol sampling station for environmental radiation monitoring

    International Nuclear Information System (INIS)

    Toivonen, H.; Honkamaa, T.; Ilander, T.; Leppaenen, A.; Nikkinen, M.; Poellaenen, R.; Ylaetalo, S.

    1998-07-01

    An automated high-volume aerosol sampling station, known as CINDERELLA.STUK, for environmental radiation monitoring has been developed by the Radiation and Nuclear Safety Authority (STUK), Finland. The sample is collected on a glass fibre filter (attached into a cassette), the airflow through the filter is 800 m 3 /h at maximum. During the sampling, the filter is continuously monitored with Na(I) scintillation detectors. After the sampling, the large filter is automatically cut into 15 pieces that form a small sample and after ageing, the pile of filter pieces is moved onto an HPGe detector. These actions are performed automatically by a robot. The system is operated at a duty cycle of 1 d sampling, 1 d decay and 1 d counting. Minimum detectable concentrations of radionuclides in air are typically 1Ae10 x 10 -6 Bq/m 3 . The station is equipped with various sensors to reveal unauthorized admittance. These sensors can be monitored remotely in real time via Internet or telephone lines. The processes and operation of the station are monitored and partly controlled by computer. The present approach fulfils the requirements of CTBTO for aerosol monitoring. The concept suits well for nuclear material safeguards, too

  11. Determination of Carbon-14 in environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia, M. R.; Gomez, V.; Heras, M. C.; Beltran, M. A.

    1990-01-01

    A method for the determination of Carbon-14 (14CO2) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO2) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discussed and compared. The method of collection of atmospheric samples is also described. (Author) 10 refs

  12. Objective sampling design in a highly heterogeneous landscape - characterizing environmental determinants of malaria vector distribution in French Guiana, in the Amazonian region.

    Science.gov (United States)

    Roux, Emmanuel; Gaborit, Pascal; Romaña, Christine A; Girod, Romain; Dessay, Nadine; Dusfour, Isabelle

    2013-12-01

    Sampling design is a key issue when establishing species inventories and characterizing habitats within highly heterogeneous landscapes. Sampling efforts in such environments may be constrained and many field studies only rely on subjective and/or qualitative approaches to design collection strategy. The region of Cacao, in French Guiana, provides an excellent study site to understand the presence and abundance of Anopheles mosquitoes, their species dynamics and the transmission risk of malaria across various environments. We propose an objective methodology to define a stratified sampling design. Following thorough environmental characterization, a factorial analysis of mixed groups allows the data to be reduced and non-collinear principal components to be identified while balancing the influences of the different environmental factors. Such components defined new variables which could then be used in a robust k-means clustering procedure. Then, we identified five clusters that corresponded to our sampling strata and selected sampling sites in each stratum. We validated our method by comparing the species overlap of entomological collections from selected sites and the environmental similarities of the same sites. The Morisita index was significantly correlated (Pearson linear correlation) with environmental similarity based on i) the balanced environmental variable groups considered jointly (p = 0.001) and ii) land cover/use (p-value sampling approach. Land cover/use maps (based on high spatial resolution satellite images) were shown to be particularly useful when studying the presence, density and diversity of Anopheles mosquitoes at local scales and in very heterogeneous landscapes.

  13. Modern Trends in Neutron Activation Analysis. Applications to some African Environmental Samples

    International Nuclear Information System (INIS)

    Hassan, A.M.

    2009-01-01

    This review covers the results of several published articles which deal with the modern trends in neutron activation analysis techniques using some of African research reactors for some environmental samples. The samples used have been collected from different areas in Egypt, South Africa, Ghana, Morocco, Nigeria, and Algeria. The neutron irradiation facilities and the advanced detection systems in each country are outlined. The prompt and delayed gamma-rays emitted due to neutron capture have been applied for investigation of the elemental constituents of such samples. Covered applications include exploration, mining, industrial environment, pollution of air, foodstuffs, soils and irrigation water samples. Some of the developed software programmes as well as the modern methods of data analysis are presented. The thermal and epithermal neutron activation analysis techniques have been applied for estimation of major, minor and trace elements in each material. Some of these data are presented with several comments.

  14. Sampling and measurement of long-lived radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Brauer, F.P.; Goles, R.W.; Kaye, J.H.; Rieck, H.G. Jr.

    1977-01-01

    The volatile and semivolatile long-lived man-made radionuclides 3 H, 14 C, 79 Se, 85 Kr, 99 Tc, 129 I, 135 Cs, and 137 Cs are of concern in operation of nuclear facilities because they are difficult and expensive to contain and once emitted to the environment they become permanent ecological constituents with both local and global distributions. Species-selective sampling and analytical methods (radiochemical, neutron activation, and mass spectrometric) have been developed for many of these nuclides with sensitivities well below those required for radiation protection. These sampling and analytical methods have been applied to the measurement of current environmental levels of some of the more ecologically important radionuclides. The detection and tracing of long-lived radionuclides is being conducted in order to establish base-line values and to study environmental behavior. This paper describes detection and measurement techniques and summarizes current measurement results

  15. The use of at-sea-sampling data to dissociate environmental variability in Norway lobster (Nephrops norvegicus) catches to improve resource efficiency

    DEFF Research Database (Denmark)

    Feekings, Jordan P.; Christensen, Asbjørn; Jonsson, Patrik

    2014-01-01

    The primary aim of this study was to determine whether the information collected as part of the at-sea-sampling program could be used to identify hydrographical and environmental variables that are influential on catch rates of Norway lobster. Ultimately, we wanted to know whether environmental...

  16. Fieldwork and catalogue of samples collected in Polan, September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Poulsen, N.; Drewniak, A.; Glowniak, E.; Ineson, J.; Matyja, B.A.; Merta, T.; Wierzbowski, A.

    1995-12-31

    This report lists the collection of samples taken during the field work of the EFP-95 Project, named `The Polish Middle to Late Jurassic Epicratonic basin, stratigraphy, facies and basin history` (short title: Jurrasic basin study, Poland) in Poland, August 7-20, 1995. The samples were collected for palynological studies, and/or sedimentaological studies, and/or source rock studies, and/or reservoir rock characteristics. Prepared samples (slides etc.) are stored in the collections of the GEUS, and remaining rock-material at the store of the GEUS. Field work with collection of samples for palynological studies has been carried earlier in 1988 and at the Oxfordian and Kimmeridgian Joint Working Groups Meeting 1992. (au)

  17. Evaluation of some pollutant levels in environmental samples collected from the area of the new campus of Taif University.

    Science.gov (United States)

    Sharshar, Taher; Hassan, H Ebrahim; Arida, Hassan A; Aydarous, Abdulkadir; Bazaid, Salih A; Ahmed, Mamdouh A

    2013-01-01

    The levels of radioactivity and heavy metals in soil, plant and groundwater samples collected from the area of the new campus of Taif University, Saudi Arabia, and its neighbouring areas have been determined. High-resolution gamma-ray spectroscopy was used for radioactivity measurements, and inductively coupled plasma atomic emission spectroscopy was used to determine the concentration of heavy metals. The means of (226)Ra, (228)Ra and (40)K concentrations in water samples collected from four wells were found to be 0.13 ± 0.03, 0.05 ± 0.03 and 1.3 ± 0.5 Bq l(-1), respectively. The means of (238)U, (226)Ra, (228)Ra ((232)Th for soil samples) and (40)K concentrations in wild plant and soil samples were found to be 3.7 ± 4.1, 8.8 ± 11.6, 3.8 ± 2.9 and 1025 ± 685, and 8.6 ± 3.4, 12.8 ± 3.4, 16.6 ± 7.1 and 618 ± 82 Bq kg(-1) dry weight (DW), respectively. The (137)Cs of artificial origin was also detected in soil samples with a mean concentration of 3.8 ± 2.2 Bq kg(-1) DW. Evaluating the results, it can be concluded that the concentrations of (238)U, (226)Ra, (232)Th and (40)K in soil samples fall within the world average. Furthermore, 19 trace and major elements in groundwater samples and 22 elements in soil and plant samples were determined. The sampling locations of soil can be classified into three groups (relatively high, medium and low polluted) according to their calculated metal pollution index using the contents of trace and major elements. A cluster analysis of the contents of radioactivity and trace element contents in soil samples shows the presence of two main distinct clusters of sampling locations.

  18. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    Science.gov (United States)

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of

  19. Acceptability of self-collected versus provider-collected sampling for HPV DNA testing among women in rural El Salvador.

    Science.gov (United States)

    Rosenbaum, Alan J; Gage, Julia C; Alfaro, Karla M; Ditzian, Lauren R; Maza, Mauricio; Scarinci, Isabel C; Felix, Juan C; Castle, Philip E; Villalta, Sofia; Miranda, Esmeralda; Cremer, Miriam L

    2014-08-01

    To determine the acceptability of self-collected versus provider-collected sampling among women participating in public sector HPV-based cervical cancer screening in El Salvador. Two thousand women aged 30-49 years underwent self-collected and provider-collected sampling with careHPV between October 2012 and March 2013 (Qiagen, Gaithersburg, MD, USA). After sample collection, a random sample of women (n=518) were asked about their experience. Participants were questioned regarding sampling method preference, previous cervical cancer screening, HPV and cervical cancer knowledge, HPV risk factors, and demographic information. All 518 women approached to participate in this questionnaire study agreed and were enrolled, 27.8% (142 of 511 responding) of whom had not received cervical cancer screening within the past 3 years and were considered under-screened. Overall, 38.8% (n=201) preferred self-collection and 31.9% (n=165) preferred provider collection. Self-collection preference was associated with prior tubal ligation, HPV knowledge, future self-sampling preference, and future home-screening preference (P<0.05). Reasons for self-collection preference included privacy/embarrassment, ease, and less pain; reasons cited for provider-collection preference were result accuracy and provider knowledge/experience. Self-sampling was found to be acceptable, therefore screening programs could consider offering this option either in the clinic or at home. Self-sampling at home may increase coverage in low-resource countries and reduce the burden that screening places upon clinical infrastructure. Copyright © 2014 International Federation of Gynecology and Obstetrics. All rights reserved.

  20. Determination of 90Sr in environmental samples with resonance ionization spectroscopy in collinear geometry

    International Nuclear Information System (INIS)

    Zimmer, K.; Stenner, J.; Kluge, H.J.; Lantzsch, J.; Monz, L.; Otten, E.W.; Passler, G.; Schwalbach, R.; Schwarz, M.; Stevens, H.; Wendt, K.; Herrmann, G.; Niess, S.; Trautmann, N.; Walter, K.; Bushaw, B.A.

    1994-01-01

    A new, fast technique for trace analysis of the radioactive isotopes 89 Sr and 90 Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the 90 Sr content in ∼ 870 m 3 air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of 90 Sr was measured to be 1.4 mBq per m 3 , corresponding to 1.6 x 10 9 atoms of 90 Sr per sample. This value is in good agreement with the results of radiochemical measurements. (orig.)

  1. Detection of iodine-129 in some environmental samples

    International Nuclear Information System (INIS)

    Ikeda, Nagao

    1981-01-01

    The recent accumulation of the long-lived isotope of iodine, 129 I, which is released in environment by the peaceful use of nuclear energy or nuclear test explosion is becoming important in the view point of the internal exposure by the low level radiation. The studies on the detection of determination of 129 I in environmental samples so far published are still very few. The authors tried to detect 129 I in some Japanese seaweeds and soil samples with the aid of the activation method by using the nuclear reaction of 129 I(n, #betta#) 130 I. The samples analysed in this work are tangle (Laminaria japonica) for daily food grown in Hidaka, Hokkaido and uncultivated soil collected in Tokai, Ibaraki Pref. As the #betta#-ray peak indicator for 130 I, cesium oxide and the aged radioisotope product of 131 I are also subjected to the neutron irradiation. From cesium oxide, 130 I is formed by the reaction of 133 Cs(n, α) 130 I. An aged vial of the 131 I product is expected to contain very minute amounts of 129 I which is also produced both by the fission of uranium and neutron capture reaction of tellurium followed by #betta# - -decay. The #betta#-ray spectra for the soil sample, cesium oxide and the aged 131 I vial are shown in Fig. 1. No appreciable peak was found for the seaweeds sample. In the #betta#-ray spectra for irradiated cesium oxide and the aged 131 I vial, several typical peaks for 130 I were observed. By comparing with these peaks, several small peaks which appear at around 418, 536 and 739 keV in the soil sample can be attributed to those of 130 I. The 129 I content in the soil sample is roughly estimated to be 2 x 10 - 10 Bq/g. (author)

  2. Development of analytical techniques for safeguards environmental samples at JAEA

    International Nuclear Information System (INIS)

    Sakurai, Satoshi; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, Chi-Gyu; Yasuda, Kenichiro; Inagawa, Jun; Suzuki, Daisuke; Iguchi, Kazunari; Kokubu, Yoko S.; Miyamoto, Yutaka; Ohzu, Akira

    2007-01-01

    JAEA has been developing, under the auspices of the Ministry of Education, Culture, Sports, Science and Technology of Japan, analytical techniques for ultra-trace amounts of nuclear materials in environmental samples in order to contribute to the strengthened safeguards system. Development of essential techniques for bulk and particle analysis, as well as screening, of the environmental swipe samples has been established as ultra-trace analytical methods of uranium and plutonium. In January 2003, JAEA was qualified, including its quality control system, as a member of the JAEA network analytical laboratories for environmental samples. Since 2004, JAEA has conducted the analysis of domestic and the IAEA samples, through which JAEA's analytical capability has been verified and improved. In parallel, advanced techniques have been developed in order to expand the applicability to the samples of various elemental composition and impurities and to improve analytical accuracy and efficiency. This paper summarizes the trace of the technical development in environmental sample analysis at JAEA, and refers to recent trends of research and development in this field. (author)

  3. Evaluation of environmental samples containing heavy hydrocarbon components in environmental forensic investigations

    Energy Technology Data Exchange (ETDEWEB)

    Raia, J.C.; Blakley, C.R.; Fuex, A.N.; Villalanti, D.C.; Fahrenthold, P.D. [Triton Anal Corp, Houston, TX (United States)

    2004-03-01

    This article presents a procedure to evaluate and characterize environmental samples containing mixtures of hydrocarbons over a wide boiling range of materials that include fuels and other products used in commerce. The range of the method extends to the higher boiling and heavier molecular weight hydrocarbon products in the range of motor oil, bunker fuel, and heavier residue materials. The procedure uses the analytical laboratory technique of high-temperature simulated distillation along with mathematical regression of the analytical data to estimate the relative contribution of individual products in mixtures of hydrocarbons present in environmental samples. An analytical technique to determine hydrocarbon-type distributions by gas chromatography-mass spectrometry with nitric oxide ionization spectrometry evaluation is also presented. This type of analysis allows complex hydrocarbon mixtures to be classified by their chemical composition, or types of hydrocarbons that include paraffins, cycloparaffins, monoaromatics, and polycyclic aromatic hydrocarbons. Characteristic hydrocarbon patterns for example, in the relative distribution of polycyclic aromatic hydrocarbons are valuable for determining the potential origin of materials present in environmental samples. These methods provide quantitative data for hydrocarbon components in mixtures as a function of boiling range and 'hydrocarbon fingerprints' of the types of materials present. This information is valuable in assessing environmental impacts of hydrocarbons at contaminated sites and establishing the liabilities and cost allocations for responsible parties.

  4. Analysis of polychlorinated n-alkanes in environmental samples.

    Science.gov (United States)

    Santos, F J; Parera, J; Galceran, M T

    2006-10-01

    Polychlorinated n-alkanes (PCAs), also known as chlorinated paraffins (CPs), are highly complex technical mixtures that contain a huge number of structural isomers, theoretically more than 10,000 diastereomers and enantiomers. As a consequence of their persistence, tendency to bioaccumulation, and widespread and unrestricted use, PCAs have been found in aquatic and terrestrial food webs, even in rural and remote areas. Recently, these compounds have been included in regulatory programs of several international organizations, including the US Environmental Protection Agency and the European Union. Consequently, there is a growing demand for reliable methods with which to analyze PCAs in environmental samples. Here, we review current trends and recent developments in the analysis of PCAs in environmental samples such as air, water, sediment, and biota. Practical aspects of sample preparation, chromatographic separation, and detection are covered, with special emphasis placed on analysis of PCAs using gas chromatography-mass spectrometry. The advantages and limitations of these techniques as well as recent improvements in quantification procedures are discussed.

  5. Metagenomic covariation along densely sampled environmental gradients in the Red Sea

    Science.gov (United States)

    Thompson, Luke R; Williams, Gareth J; Haroon, Mohamed F; Shibl, Ahmed; Larsen, Peter; Shorenstein, Joshua; Knight, Rob; Stingl, Ulrich

    2017-01-01

    Oceanic microbial diversity covaries with physicochemical parameters. Temperature, for example, explains approximately half of global variation in surface taxonomic abundance. It is unknown, however, whether covariation patterns hold over narrower parameter gradients and spatial scales, and extending to mesopelagic depths. We collected and sequenced 45 epipelagic and mesopelagic microbial metagenomes on a meridional transect through the eastern Red Sea. We asked which environmental parameters explain the most variation in relative abundances of taxonomic groups, gene ortholog groups, and pathways—at a spatial scale of water mass with different physicochemical properties. Temperature explained the most variation in each metric, followed by nitrate, chlorophyll, phosphate, and salinity. That nitrate explained more variation than phosphate suggested nitrogen limitation, consistent with low surface N:P ratios. Covariation of gene ortholog groups with environmental parameters revealed patterns of functional adaptation to the challenging Red Sea environment: high irradiance, temperature, salinity, and low nutrients. Nutrient-acquisition gene ortholog groups were anti-correlated with concentrations of their respective nutrient species, recapturing trends previously observed across much larger distances and environmental gradients. This dataset of metagenomic covariation along densely sampled environmental gradients includes online data exploration supplements, serving as a community resource for marine microbial ecology. PMID:27420030

  6. Evaluation of standard methods for collecting and processing fuel moisture samples

    Science.gov (United States)

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  7. Monitoring PCDD/Fs in soil and herbage samples collected in the neighborhood of a hazardous waste incinerator after five years of operation

    Energy Technology Data Exchange (ETDEWEB)

    Nadal, M.; Bocio, A.; Schuhmacher, M.; Liobet, J.M.; Domingo, J.L. [Rovira i Virgili Univ., Reus (Spain); Diaz-Ferrero, J. [Inst. Quimic de Sarria, Barcelona (Spain)

    2004-09-15

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are among the most dangerous environmental pollutants, usually generated during combustion processes. Until recently, waste incineration was widely referenced as one of the most important sources of PCDD/F release to the atmosphere. In 1999, the only hazardous waste incinerator (HWI) in Spain began regular operations. This facility is placed in Tarragona, Catalonia. The presence of this HWI, as well as that of a municipal solid waste incinerator (MSWI) at a few kilometers, increased the concern of the public opinion in relation to the potential toxic emissions, especially those of metals and PCDD/Fs, which could affect the health of the population living in the area. Previously to regular operations (1996) the baseline levels of PCDD/Fs in soil and vegetation samples collected near the HWI were determined. A second survey was carried out two years later (1998) in order to establish the temporal variation in PCDD/F concentrations in soil and vegetation samples taken at the same sampling points. Vegetation is considered an adequate short-term environmental monitor for PCDD/Fs. Therefore, in the surveillance program of the facility (1999-2003), herbage samples (40) were annually collected at the same sampling points in which baseline samples had been taken. Moreover, considering soil as a suitable long-term monitor for PCDD/Fs, 40 soil samples in this matrix were again collected in 2001 and 2003 to examine the temporal variations of PCDD/F levels in the area. In the present study, we present the concentrations of PCDD/Fs in soil and vegetation samples collected in the vicinity of the HWI after 5 years of regular operations.

  8. Rapid Identification of a Cooling Tower-Associated Legionnaires' Disease Outbreak Supported by Polymerase Chain Reaction Testing of Environmental Samples, New York City, 2014-2015.

    Science.gov (United States)

    Benowitz, Isaac; Fitzhenry, Robert; Boyd, Christopher; Dickinson, Michelle; Levy, Michael; Lin, Ying; Nazarian, Elizabeth; Ostrowsky, Belinda; Passaretti, Teresa; Rakeman, Jennifer; Saylors, Amy; Shamoonian, Elena; Smith, Terry-Ann; Balter, Sharon

    2018-04-01

    We investigated an outbreak of eight Legionnaires' disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings.

  9. GAINS IN PERFORMANCE OF DIFFERENT METHODS OF COLLECTING ENTOMOLOGICAL MATERIALS IN ENVIRONMENTAL AND FAUNAL STUDIES ON COLEOPTERA

    Directory of Open Access Journals (Sweden)

    B. N. Saypulaeva

    2015-01-01

    Full Text Available The aim is to study the effectiveness of methods of collecting entomological materials for further ecological and faunal studies as well as to gain the main evidence in ecological and faunal studies carried out in the field. Collection of the evidence in the field is necessary for the identification of species composition and to study such aspects as the distribution of species, confinement of species to certain habitats, relations with the food objects (trophism, climate, soil and orographic environmental factors.Methodology. We have used the traditional methods of collection (hand picking, pitfall traps, pitfall traps with increased light, light traps, processing and determination of materials. In recent years, the method of collection of soil invertebrates has introduced an innovation. In expeditionary studies in the island of Tyuleny new ways have been tested of using pitfall traps equipped with an incandescent light source. They provide a higher collection efficiency of Entomological materials. List of species composition of the discussed fauna has been composed by modern taxonomy with the use of directories.Results. We have made a comparative analysis of the effectiveness of different methods of collecting entomological materials on Coleoptera (Carabidae, Scarabaeidae, Elateridae, Tenebrionidae for environmental and faunal studies in the area of Irganayskaya arid basin of intramontane Dagestan. Not all species, registered in the studied habitat, have been identified by methods of soil sampling and pitfall traps. The greatest number of species has been identified by manual collection, and the least by soil sampling. The paper shows the effectiveness of different methods of collecting entomofauna against individual families and species of the groups studied.

  10. Curating NASA's Past, Present, and Future Astromaterial Sample Collections

    Science.gov (United States)

    Zeigler, R. A.; Allton, J. H.; Evans, C. A.; Fries, M. D.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC

  11. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  12. Radioactivity in Soil Samples Collected in Southern Serbia

    International Nuclear Information System (INIS)

    Jankovic, M.; Nikolic, J.; Pantelic, G.; Rajacic, M.; Sarap, N.; Todorovic, D.

    2013-01-01

    In the attack on the Federal Republic of Yugoslavia (the focus effect was of Kosovo and Metohija and southern Serbia) in 1999, NATO forces used ammunition containing depleted uranium. Cleaning action of depleted uranium was performed by Radiation and Environmental Protection Department of the Vinca Institute of Nuclear Science, during 2002?2007 at locations: Pljackovica, Bratoselce, Borovac and Reljan. At all locations underwent detailed dosimetric screening and decontamination was performed. Because of the loose soil, DU projectils were found to a depth of 1 m. Found missiles, contaminated soil and radioactive material has been collected and stored on radioactive waste. After cleaning the ground is leveled and another dosimetric prospecting was performed. Monitoring of radioactivity in southern Serbia included determination of gamma emitters as well as determination of gross alpha and beta activities in soil, water and plant. Sampling was carried out at Pljackovica, Borovac, Bratoselce and Reljan in July 2011. This paper presents only the results of measurement of gamma emitters in soil samples and showed the presence of natural radionuclides: 226Ra, 232Th, 40K, 235U, 238U and the produced radionuclide 137Cs (from the Chernobyl accident). Also, the ratio between the 235U and 238U is given. In order to evaluate the radiological hazard of the natural radioactivity, the radium equivalent activity, the gamma-absorbed dose rate and the external hazard index have been calculated. (author)

  13. Environmental radiation levels in soil and sediment samples collected from floating water from a land runway resulting from heavy rains in the Jeddah region, KSA

    International Nuclear Information System (INIS)

    Mohery, M.; Baz, Shadiah; Kelany, Adel M.; Abdallah, A.M.

    2014-01-01

    The natural radiation levels in soil and sediment samples collected from floating water from a land runway resulting from heavy rains in the Jeddah region as well as the activity in the population of its surrounding environments were studied. In the regions surrounding Jeddah, the movements of floating water may increase the concentration of radioactivity due to the movement of soil due to heavy rains. In addition, the technological development of industry, agriculture and other sources around the Jeddah region has increased environmental pollution, resulting in noticeable concentrations of radioactivity. The measured activity concentrations of 214 Pb, 214 Bi, 228 Ac, 208 Tl, 40 K, 226 Ra and 228 Ra in the studied area suggest that they are within the world average for soils and sediments, except those for water sample no. 4; the concentration in this sample was five times higher than the world average concentration (this water is not consumable). Herein, the radioactivity concentrations that were obtained from the analysis of soil and sediment samples that were collected from the investigated area are discussed. Additionally, the absorbed dose rate (D), radium equivalent activity (Ra eq ), external hazard index (H ex ), annual gonadal dose equivalent (AGDE) and annual effective dose equivalent (AEDE) were evaluated. For the soil and sediment samples, the average radioactivity concentrations were determined for each site and are expressed in Becquerels per kilogram (Bq/kg) of dry weight, while for the measurement of both the 226 Ra and 228 Ra isotopes in the water samples, the activity concentration is expressed in picoCuries per liter (pCi/l). The obtained results were compared with other measurements from different countries. The movement of floating water around the Jeddah region increases the concentration of radioactivity due to the movement of soils with heavy rains. - Highlights: • The natural radiation levels in soil and sediment samples from floating

  14. o-TOF ICPMS analysis of environmental, food and biological samples

    International Nuclear Information System (INIS)

    Krejcova, A.; Cernohorsky, T.; Ludvikova, I.; Pouzar, M.; Capova, L.

    2009-01-01

    Full text: o-TOF ICPMS was used for inorganic analysis of environmental, food and biological samples. The method validity was proved by analysis of spiked samples, reference materials, by determination without/with internal standards and the standard addition technique. The technique was shown to be powerful, and reliable for analysis of the samples mentioned, and high sample throughput enables environmental or biological screening studies. Independent of the number of elements analyzed, complete analysis and whole mass spectra are gained from a small sample amount in a very short time. (author)

  15. Transuranium analysis methodologies for biological and environmental samples

    International Nuclear Information System (INIS)

    Wessman, R.A.; Lee, K.D.; Curry, B.; Leventhal, L.

    1978-01-01

    Analytical procedures for the most abundant transuranium nuclides in the environment (i.e., plutonium and, to a lesser extent, americium) are available. There is a lack of procedures for doing sequential analysis for Np, Pu, Am, and Cm in environmental samples, primarily because of current emphasis on Pu and Am. Reprocessing requirements and waste disposal connected with the fuel cycle indicate that neptunium and curium must be considered in environmental radioactive assessments. Therefore it was necessary to develop procedures that determine all four of these radionuclides in the environment. The state of the art of transuranium analysis methodology as applied to environmental samples is discussed relative to different sample sources, such as soil, vegetation, air, water, and animals. Isotope-dilution analysis with 243 Am ( 239 Np) and 236 Pu or 242 Pu radionuclide tracers is used. Americium and curium are analyzed as a group, with 243 Am as the tracer. Sequential extraction procedures employing bis(2-ethyl-hexyl)orthophosphoric acid (HDEHP) were found to result in lower yields and higher Am--Cm fractionation than ion-exchange methods

  16. A Prototype Ice-Melting Probe for Collecting Biological Samples from Cryogenic Ice at Low Pressure

    Science.gov (United States)

    Davis, Ashley

    2017-08-01

    In the Solar System, the surface of an icy moon is composed of irregular ice formations at cryogenic temperatures (pumps. The device contains a heated conical probe with a central orifice, which is forced into surface ice and directs the meltwater upward into a reservoir. The force on the probe is proportional to the height of meltwater (pressure) obtained in the system and allows regulation of the melt rate and temperature of the sample. The device can collect 5-50 mL of meltwater from the surface of an ice block at 233-208 K with an environmental pressure of less than 10-2 atm while maintaining a sample temperature between 273 and 293 K. These conditions maintain most biological samples in a pristine state and maintain the integrity of most organisms' structure and function.

  17. Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

    International Nuclear Information System (INIS)

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-06-01

    This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text

  18. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples....... This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...

  19. Rapid Identification of a Cooling Tower-Associated Legionnaires’ Disease Outbreak Supported by Polymerase Chain Reaction Testing of Environmental Samples, New York City, 2014–2015

    Science.gov (United States)

    Benowitz, Isaac; Fitzhenry, Robert; Boyd, Christopher; Dickinson, Michelle; Levy, Michael; Lin, Ying; Nazarian, Elizabeth; Ostrowsky, Belinda; Passaretti, Teresa; Rakeman, Jennifer; Saylors, Amy; Shamoonian, Elena; Smith, Terry-Ann; Balter, Sharon

    2018-01-01

    We investigated an outbreak of eight Legionnaires’ disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings. PMID:29780175

  20. Importance of sampling frequency when collecting diatoms

    KAUST Repository

    Wu, Naicheng; Faber, Claas; Sun, Xiuming; Qu, Yueming; Wang, Chao; Ivetic, Snjezana; Riis, Tenna; Ulrich, Uta; Fohrer, Nicola

    2016-01-01

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected

  1. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 1993

    International Nuclear Information System (INIS)

    Conrad, R.; Childs, M.; Rivera-Dirks, C.; Coriz, F.

    1995-07-01

    Area G, in Technical Area 54, has been the principle facility at Los Alamos National Laboratory for the storage and disposal of low-level and transuranic (TRU) radioactive wastes since 1957. The current environmental investigation consisted of ESH-19 personnel who collected soil and single-stage water samples around the perimeter of Area G to characterize possible contaminant movement through surface-water runoff. These samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241 (soil only), and cesium 137. The metals, mercury, lead, and barium, were analyzed using x-ray fluorescence

  2. Protocol for collecting eDNA samples from streams [Version 2.3

    Science.gov (United States)

    K. J. Carim; T. Wilcox; M. K. Young; K. S. McKelvey; M. K. Schwartz

    2015-01-01

    Throughout the 2014 field season, we had over two dozen biologist throughout the western US collect over 300 samples for eDNA analysis with paired controls. Control samples were collected by filtering 0.5 L of distilled water. No samples had any evidence of field contamination. This method of sampling verifies the cleanliness of the field equipment, as well as the...

  3. Environmental sampling: Issues for the cut-off regime

    International Nuclear Information System (INIS)

    Fearey, B.L.

    1995-01-01

    The fissile material cut-off treaty (FMCT) initiative under the Conference on Disarmament mandate is envisioned to include certain aspects of environmental sampling and monitoring. One of the intents of this treaty is to bring certain non-NPT signatories (e.g., threshold states) under this treaty agreement along with the nuclear weapon states (NWSs). This paper provides a brief overview of some of the relevant issues that may be involved in the implementation and use of environmental monitoring for (1) verification of the cut-off regime declarations, (2) the detection of undeclared activities, and, (3) application in non-routine inspections. The intent is to provide backstopping information important for treaty negotiators. Specific issues addressed within this paper include signature sampling, differences in the proposed detection regime, potential signature integrators, specific examples and spoofing concerns. Many of these issues must be carefully considered and weighed in order to create a credibly verifiable inspection regime. Importantly, the cut-off treaty must enable nondiscriminatory implementation, while carefully assuring that nonproliferation treaty requirements are maintained (i.e., preventing unintentional release of critical weapons design information--potentially through environmental sampling and analysis)

  4. Sorption models and their application in environmental samples

    International Nuclear Information System (INIS)

    Kamel, Nariman H.M.

    2008-01-01

    Full text: Naturally occurring radioactive materials (NORM) were found in some environmental soils not high enough to pose problems for human health. The health may be affected by increasing of NORM at some environmental soils. Four soil samples obtained from certain coastal regions in Egypt. Naturally occurring radioactive materials (NORM) of the uranium ( 238 U) series, thorium ( 232 Th) series and the radioactive isotope of potassium ( 40 K) were measured. The soil samples were selected from the situations where the radionuclide concentrations are significantly higher than the average level of other sites. It were chemically analyzed for the uranium, silicon aluminum and iron. The cation exchange capacity (CEC) were determined, it was found lower in the presence of Fe-silicates suggested that Fe-hydroxide had precipitin at the exchangeable edge sites of the clay minerals. The pH of the solid particles at which the net total surface charge is zero was known as the point of zero charge (PZC). The PZC is very important in determining the affinity of the soil samples for different cations and anions. The aim of this work is to determine the natural radiological hazardous of radionuclide at four environmental coastal soil samples in Egypt. The point of zero surface charge was determined using titration tests. Sorption model was developed for this purpose. (author)

  5. Sample collection and sample analysis plan in support of the 105-C/190-C concrete and soil sampling activities

    International Nuclear Information System (INIS)

    Marske, S.G.

    1996-07-01

    This sampling and analysis plan describes the sample collection and sample analysis in support of the 105-C water tunnels and 190-C main pumphouse concrete and soil sampling activities. These analytical data will be used to identify the radiological contamination and presence of hazardous materials to support the decontamination and disposal activities

  6. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy`s (DOE`s) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples.

  7. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    International Nuclear Information System (INIS)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy's (DOE's) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples

  8. Self-attenuation of gamma rays during radioactivity concentration analysis of environmental samples

    International Nuclear Information System (INIS)

    Watson, D.; Dharmasiri, J.; Akber, R.

    2001-01-01

    Gamma spectroscopy using HPGe detector systems is a readily used technique for routine analysis of radioactivity in environmental samples. The systems are generally calibrated using standards of known radioactivity and composition. Radioactivity in environmental samples is generally distributed in the bulk of the material. When a sample of finite thickness is analysed through gamma spectroscopy, a proportion of the gamma rays emitted from the sample is either stopped or scattered from the sample material itself. These processes of self-absorption and self-attenuation depend upon the physical and elemental composition of the sample and the energy of the gamma radiation. Since environmental samples vary in composition, instrument calibration using a fixed matrix composition may not be valid for a diversity of samples. We selected and analysed five sample matrices to investigate the influence of self-absorption and self-attenuation in environmental samples. Our selection consisted of bentonite and kaolin representing clay, quartz representing silica, ash representing prepared biota, and analytical grade MnO 2 representing a co-precipitant used for extractive radioactivity from aqueous samples. Our findings show that within 5% of uncertainty the silica based standards can be used to cover the environmental samples of varying clay (silica content). The detection efficiency for ash and MnO 2 could be different particularly in the 30 - 100 keV energy range. The differences in sample behaviour can be explained on the basis of atomic number, mass number and density

  9. Effective sample labeling

    International Nuclear Information System (INIS)

    Rieger, J.T.; Bryce, R.W.

    1990-01-01

    Ground-water samples collected for hazardous-waste and radiological monitoring have come under strict regulatory and quality assurance requirements as a result of laws such as the Resource Conservation and Recovery Act. To comply with these laws, the labeling system used to identify environmental samples had to be upgraded to ensure proper handling and to protect collection personnel from exposure to sample contaminants and sample preservatives. The sample label now used as the Pacific Northwest Laboratory is a complete sample document. In the event other paperwork on a labeled sample were lost, the necessary information could be found on the label

  10. Determination of [sup 90]Sr in environmental samples with resonance ionization spectroscopy in collinear geometry

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, K. (Inst. fuer Physik, Univ. Mainz (Germany)); Stenner, J. (Inst. fuer Physik, Univ. Mainz (Germany)); Kluge, H.J. (Inst. fuer Physik, Univ. Mainz (Germany)); Lantzsch, J. (Inst. fuer Physik, Univ. Mainz (Germany)); Monz, L. (Inst. fuer Physik, Univ. Mainz (Germany)); Otten, E.W. (Inst. fuer Physik, Univ. Mainz (Germany)); Passler, G. (Inst. fuer Physik, Univ. Mainz (Germany)); Schwalbach, R. (Inst. fuer Physik, Univ. Mainz (Germany)); Schwarz, M. (Inst. fuer Physik, Univ. Mainz (Germany)); Stevens, H. (Inst. fuer Physik, Univ. Mainz (Germany)); Wendt, K. (Inst. fuer Physik, Univ. Mainz (Germany)); Herrmann, G. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Niess, S. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Trautmann, N. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Walter, K. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Bushaw, B.A. (Pacific Northwest Lab., Richland, WA (United States))

    1994-08-01

    A new, fast technique for trace analysis of the radioactive isotopes [sup 89]Sr and [sup 90]Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the [sup 90]Sr content in [approx] 870 m[sup 3] air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of [sup 90]Sr was measured to be 1.4 mBq per m[sup 3], corresponding to 1.6 x 10[sup 9] atoms of [sup 90]Sr per sample. This value is in good agreement with the results of radiochemical measurements. (orig.)

  11. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Veterinary antibiotic resistance, residues, and ecological risks in environmental samples obtained from poultry farms, Egypt.

    Science.gov (United States)

    Dahshan, Hesham; Abd-Elall, Amr Mohamed Mohamed; Megahed, Ayman Mohamed; Abd-El-Kader, Mahdy A; Nabawy, Ehab Elsayed

    2015-02-01

    In Egypt, poultry production constitutes one of the main sources of pollution with veterinary antibiotics (VAs) into the environment. About 80 % of meat production in Egypt is of poultry origin, and the potential environmental risks associated with the use of VAs in these farms have not yet been properly evaluated. Thus, the main purpose of this research was to evaluate the prevalence of antibiotic-resistant enteric key bacteria and the incidence of residual antibiotics in poultry farm environmental samples and to determine whether fertilizing soils with poultry litter from farms potentially brings ecological risks. From December 2011 to September 2012, a total of 225 litter, bird dropping, and water samples were collected from 75 randomly selected boiler poultry farms. A high prevalence of Escherichia coli (n = 179; 79.5 %) in contrast to the low prevalence of Salmonella spp. (n = 7; 3.1 %) was detected. Amongst E. coli isolates, serotypes O142:K86, O125:K70, O91:K, and O119:K69 were the most common. Meanwhile, Salmonella enterica serotypes emek and enteritidis were recovered. The antibiograms using the disc diffusion method revealed significantly more common resistant and multi-resistant isolates in broiler poultry farms. Residues of tetracycline and ciprofloxacin were detected at 2.125 and 1.401 mg kg(-1) mean levels, respectively, in environmental samples contaminated with E. coli-resistant strains by HPLC. The risk evaluations highlighted that tetracycline residues in poultry litter significantly display environmental risks with a hazard quotient value above 1 (1.64). Our study implies that ineffective implementation of veterinary laws which guide and guard against incorrect VA usage may potentially bring health and environmental risks.

  13. The determination of plutonium isotopes in environmental samples

    International Nuclear Information System (INIS)

    Siripirom, Lopchai.

    1983-01-01

    The concentration of plutonium in environmental samples such as soil, water, and surface air in the middle part of Thailand were studied. The surface air were collected only at the fifth floor of the Office of Atomic Energy for Peace (OAEP). Plutonium-242 was used as a tracer. Soil and air samples were dissolved by pyrosulphate fusion, and plutonium was co-precipitated with barium sulfate. Then dissolved the precipitate in perchloric acid. Plutonium was extracted out by using solvent bis-(2-ethylhexyl) phosphoric acid (HDEHP). Plutonium in water samples were coprecipitated with iron (III) hydroxide and were dissolved in 8 M. nitric acid. Then the plutonium was separated out by using anion exchange resin, Dowex 1x4. After the solvent extraction or the anion exchange, plutonium was coprecipitated with cerous hydroxide. The activities of plutonium were measured by a surface barrier detector for about 24 hours. Lower limit of detection for 1,440 minutes is 0.012 pCi. These studies showed that only plutonium-239, 240 was observed. The range of activities of plutonium-239, 240 in soil were 0.002-0.157 pCi/g (dry), in water were 0.1-81 f Ci/l, and in air were 7-330 a Ci/m 3 . However, the plutonium concentrations in these studies are far below the maximum permissible concentration (MPC) recommended by International Commission on Radiological Protection (ICRP) for general population which is equal to 3x10 8 f Ci/l of water and 5x10 6 a Ci/m 3 of air

  14. Environmental DNA from seawater samples correlate with trawl catches of Subarctic, deepwater fishes

    DEFF Research Database (Denmark)

    Thomsen, Philip Francis; Møller, Peter Rask; Sigsgaard, Eva Egelyng

    2016-01-01

    such as bottom trawling, and on official reporting of global catches, which can be unreliable. Thus, there is need for alternative and non-invasive techniques for qualitative and quantitative oceanic fish surveys. Here we report environmental DNA (eDNA) metabarcoding of seawater samples from continental slope...... depths in Southwest Greenland. We collected seawater samples at depths of 188-918 m and compared seawater eDNA to catch data from trawling. We used Illumina sequencing of PCR products to demonstrate that eDNA reads show equivalence to fishing catch data obtained from trawling. Twenty-six families were...... found with both trawling and eDNA, while three families were found only with eDNA and two families were found only with trawling. Key commercial fish species for Greenland were the most abundant species in both eDNA reads and biomass catch, and interpolation of eDNA abundances between sampling sites...

  15. Determination of Pu, Am and Cm in Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Lujaniene, G. [SRI Centre for Physical Sciences and Technology, Vilnius (Lithuania)

    2013-07-15

    The determination of actinides in the environmental samples at a lower detection limit is required for monitoring purposes and for environmental research. The method for Pu, Am and Cm measurements in soil and sediment samples provides high recoveries and good decontamination from interfering radionuclides. The main steps of the method involve digestion of the samples, separation of radionuclides from matrix using the TOPO /cyclohexane extraction and final purification using extraction Eichrom resins (TEVA, TRU). The accuracy and precision of Pu, Am and Cm analyses were tested using IAEA RM No 135, NIST SRM No 4350b, No 4357 and in intercomparison runs organized by the Riso National Laboratory, Denmark, and in the proficiency tests organized by National Physical Laboratory, UK. The method was applied for measurement of radionuclides in aerosol samples (ashes {approx}30 g), bottom sediments (50-80 g dr. wt) and soil (including Chernobyl soil) samples. (author)

  16. 78 FR 50079 - Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed...

    Science.gov (United States)

    2013-08-16

    ... DEPARTMENT OF THE INTERIOR Bureau of Safety and Environmental Enforcement [Docket ID BSEE-2013-0005; OMB Control Number 1014-0017: 134E1700D2 EEEE500000 ET1SF0000.DAQ000] Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed Collection; Comment Request...

  17. 78 FR 78998 - 60-Day Notice of Proposed Information Collection: HUD Environmental Review Online System (HEROS)

    Science.gov (United States)

    2013-12-27

    ... Information Collection: HUD Environmental Review Online System (HEROS) AGENCY: Office of Community Planning... Information Collection Title of Information Collection: HUD Environmental Review Online System (HEROS). OMB... online tool called the HUD Environmental Review Online System (HEROS), which will allow users to complete...

  18. [Collective health, territorial and environmental conflicts: bases for a critical socio-environmental approach].

    Science.gov (United States)

    Porto, Marcelo Firpo de Souza; da Rocha, Diogo Ferreira; Finamore, Renan

    2014-10-01

    The phenomenon of globalization and the increase in neo-extractivism in the global periphery intensify the search for new territories and natural resources for the economy, resulting in significant impacts on ecosystems and on the lives of vulnerable populations. It is considered that the environmental crisis imposes new challenges and requires an updating of the theoretical and methodological foundations of collective health and the social determinants of health. The scope of this paper is to present theoretical contributions to the construction of a critical socio-environmental approach from a review of the literature structured around previous work on the mapping of environmental conflicts, and conducting empirical studies in conflicting areas. The contributions of sociology, political ecology, postcolonial studies and geography is summarized for the discussion of the socio-environmental determinants of health, as well as experiences that integrate emancipatory knowledge, political subjects, resistances and alternatives for society.

  19. Least-squares resolution of gamma-ray spectra in environmental samples

    International Nuclear Information System (INIS)

    Kanipe, L.G.; Seale, S.K.; Liggett, W.S.

    1977-08-01

    The use of ALPHA-M, a least squares computer program for analyzing NaI (Tl) gamma spectra of environmental samples, is evaluated. Included is a comprehensive set of program instructions, listings, and flowcharts. Two other programs, GEN4 and SIMSPEC, are also described. GEN4 is used to create standard libraries for ALPHA-M, and SIMSPEC is used to simulate spectra for ALPHA-M analysis. Tests to evaluate the standard libraries selected for use in analyzing environmental samples are provided. An evaluation of the results of sample analyses is discussed

  20. AAS determination of total mercury content in environmental samples

    International Nuclear Information System (INIS)

    Moskalova, M.; Zemberyova, M.

    1997-01-01

    Two methods for determination of total mercury content in environmental samples soils, and sediments, were compared. Dissolution procedure of soils, sediments, and biological material under elevated pressure followed by determination of mercury by cold vapour atomic absorption spectrometry using a MHS-1 system and direct total mercury determination without any chemical pretreatment from soil samples using a Trace Mercury Analyzer TMA-254 were compared. TMA-254 was also applied for the determination of mercury in various further standard reference materials. Good agreement with certified values of environmental reference materials was obtained. (authors)

  1. Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives.

    Science.gov (United States)

    Verkouteren, Jennifer R; Lawrence, Jeffrey A; Staymates, Matthew E; Sisco, Edward

    2017-04-10

    One of the limiting steps to detecting traces of explosives at screening venues is effective collection of the sample. Wipe-sampling is the most common procedure for collecting traces of explosives, and standardized measurements of collection efficiency are needed to evaluate and optimize sampling protocols. The approach described here is designed to provide this measurement infrastructure, and controls most of the factors known to be relevant to wipe-sampling. Three critical factors (the applied force, travel distance, and travel speed) are controlled using an automated device. Test surfaces are chosen based on similarity to the screening environment, and the wipes can be made from any material considered for use in wipe-sampling. Particle samples of the explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) are applied in a fixed location on the surface using a dry-transfer technique. The particle samples, recently developed to simulate residues made after handling explosives, are produced by inkjet printing of RDX solutions onto polytetrafluoroethylene (PTFE) substrates. Collection efficiency is measured by extracting collected explosive from the wipe, and then related to critical sampling factors and the selection of wipe material and test surface. These measurements are meant to guide the development of sampling protocols at screening venues, where speed and throughput are primary considerations.

  2. Study on trace element determination in liver samples of great-white-egret Ardea alba Linnaeus, 1758 (Ardeidae, Aves) for environmental contamination biomionitoring

    International Nuclear Information System (INIS)

    Silva, Rita de Cassia A.; Saiki, Mitiko

    2009-01-01

    Predatory birds such as herons have been used as bioindicators of pollution since they are at the top of their food webs. The tissues of these animals are analyzed for assessing environmental pollution caused by toxic elements. In the present study, adequate experimental conditions were established for determination of trace elements concentrations in the liver samples of Great-white-egret (Ardea alba Linnaeus, 1758) for further application of this specimens as a bioindicator of environmental contamination. Four liver samples were collected from Greatwhite- egrets found in the metropolitan region of Sao Paulo and were they analyzed by the method of neutron activation analysis (NAA). Concentrations of the elements Br, Co, Cs, Fe, Na, Rb, Se and Zn were measured in these liver tissues. The findings of this present study demonstrated that the established procedure for liver sample treatment was appropriate to obtain a homogeneous sample. The method of neutron activation analysis (NAA) was very promising for liver sample analysis for evaluation of environmental contamination. (author)

  3. Study on trace element determination in liver samples of great-white-egret Ardea alba Linnaeus, 1758 (Ardeidae, Aves) for environmental contamination biomionitoring

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rita de Cassia A.; Saiki, Mitiko, E-mail: rcsilva@ipen.b, E-mail: mitiko@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Predatory birds such as herons have been used as bioindicators of pollution since they are at the top of their food webs. The tissues of these animals are analyzed for assessing environmental pollution caused by toxic elements. In the present study, adequate experimental conditions were established for determination of trace elements concentrations in the liver samples of Great-white-egret (Ardea alba Linnaeus, 1758) for further application of this specimens as a bioindicator of environmental contamination. Four liver samples were collected from Greatwhite- egrets found in the metropolitan region of Sao Paulo and were they analyzed by the method of neutron activation analysis (NAA). Concentrations of the elements Br, Co, Cs, Fe, Na, Rb, Se and Zn were measured in these liver tissues. The findings of this present study demonstrated that the established procedure for liver sample treatment was appropriate to obtain a homogeneous sample. The method of neutron activation analysis (NAA) was very promising for liver sample analysis for evaluation of environmental contamination. (author)

  4. Speciation of organotin compounds in environmental samples by GC-ICPMS

    International Nuclear Information System (INIS)

    Vahcic, M.; Milacic, R.; Scancar, J.

    2009-01-01

    Full text: Analytical procedure using 15 m GC column was applied for simultaneous speciation of OTCs in various environmental samples. Methyl-, butyl-, phenyl- and octyl- tin species were quantitatively determined. different extraction reagents and conditions were studied. OTCs species were derivatized by NaBEt 4 and extracted into isooctane or hexane. The applied analytical procedure considerably shortened analytical time and enabled simultaneous determination of 12 OTCs in environmental samples. (author)

  5. Environmental sample banking-research and methodology

    International Nuclear Information System (INIS)

    Becker, D.A.

    1976-01-01

    The National Bureau of Standards (NBS), in cooperation with the Environment Protection Agency and the National Science Foundation, is engaged in a research program establishing methodology for environmental sample banking. This program is aimed toward evaluating the feasibility of a National Environment Specimen Bank (NESB). The capability for retrospective chemical analyses to evaluate changes in our environment would provide useful information. Much of this information could not be obtained using data from previously analyzed samples. However, to assure validity for these stored samples, they must be sampled, processed and stored under rigorously evaluated, controlled and documented conditions. The program currently under way in the NBS Analytical Chemistry Division has 3 main components. The first is an extension survey of available literature concerning problems of contamination, losses and storage. The components of interest include trace elements, pesticides, other trace organics (PCBs, plasticizers, etc.), radionuclides and microbiological species. The second component is an experimental evaluation of contamination and losses during sampling and sample handling. Of particular interest here is research into container cleaning methodology for trace elements, with respect to adsorption, desorption, leaching and partial dissolution by various sample matrices. The third component of this program is an evaluation of existing methodology for long-term sample storage

  6. Self-collected versus clinician-collected sampling for sexually transmitted infections: a systematic review and meta-analysis protocol.

    Science.gov (United States)

    Taylor, Darlene; Lunny, Carole; Wong, Tom; Gilbert, Mark; Li, Neville; Lester, Richard; Krajden, Mel; Hoang, Linda; Ogilvie, Gina

    2013-10-10

    Three meta-analyses and one systematic review have been conducted on the question of whether self-collected specimens are as accurate as clinician-collected specimens for STI screening. However, these reviews predate 2007 and did not analyze rectal or pharyngeal collection sites. Currently, there is no consensus on which sampling method is the most effective for the diagnosis of genital chlamydia (CT), gonorrhea (GC) or human papillomavirus (HPV) infection. Our meta-analysis aims to be comprehensive in that it will examine the evidence of whether self-collected vaginal, urine, pharyngeal and rectal specimens provide as accurate a clinical diagnosis as clinician-collected samples (reference standard). Eligible studies include both randomized and non-randomized controlled trials, pre- and post-test designs, and controlled observational studies. The databases that will be searched include the Cochrane Database of Systematic Reviews, Web of Science, Database of Abstracts of Reviews of Effects (DARE), EMBASE and PubMed/Medline. Data will be abstracted independently by two reviewers using a standardized pre-tested data abstraction form. Heterogeneity will be assessed using the Q2 test. Sensitivity and specificity estimates with 95% confidence intervals as well as negative and positive likelihood ratios will be pooled and weighted using random effects meta-analysis, if appropriate. A hierarchical summary receiver operating characteristics curve for self-collected specimens will be generated. This synthesis involves a meta-analysis of self-collected samples (urine, vaginal, pharyngeal and rectal swabs) versus clinician-collected samples for the diagnosis of CT, GC and HPV, the most prevalent STIs. Our systematic review will allow patients, clinicians and researchers to determine the diagnostic accuracy of specimens collected by patients compared to those collected by clinicians in the detection of chlamydia, gonorrhea and HPV.

  7. Soil sample collection and analysis for the Fugitive Dust Characterization Study

    Science.gov (United States)

    Ashbaugh, Lowell L.; Carvacho, Omar F.; Brown, Michael S.; Chow, Judith C.; Watson, John G.; Magliano, Karen C.

    A unique set of soil samples was collected as part of the Fugitive Dust Characterization Study. The study was carried out to establish whether or not source profiles could be constructed using novel analytical methods that could distinguish soil dust sources from each other. The soil sources sampled included fields planted in cotton, almond, tomato, grape, and safflower, dairy and feedlot facilities, paved and unpaved roads (both urban and rural), an agricultural staging area, disturbed land with salt buildup, and construction areas where the topsoil had been removed. The samples were collected using a systematic procedure designed to reduce sampling bias, and were stored frozen to preserve possible organic signatures. For this paper the samples were characterized by particle size (percent sand, silt, and clay), dry silt content (used in EPA-recommended fugitive dust emission factors), carbon and nitrogen content, and potential to emit both PM 10 and PM 2.5. These are not the "novel analytical methods" referred to above; rather, it was the basic characterization of the samples to use in comparing analytical methods by other scientists contracted to the California Air Resources Board. The purpose of this paper is to document the methods used to collect the samples, the collection locations, the analysis of soil type and potential to emit PM 10, and the sample variability, both within field and between fields of the same crop type.

  8. Collection of biological samples in forensic toxicology.

    Science.gov (United States)

    Dinis-Oliveira, R J; Carvalho, F; Duarte, J A; Remião, F; Marques, A; Santos, A; Magalhães, T

    2010-09-01

    Forensic toxicology is the study and practice of the application of toxicology to the purposes of the law. The relevance of any finding is determined, in the first instance, by the nature and integrity of the specimen(s) submitted for analysis. This means that there are several specific challenges to select and collect specimens for ante-mortem and post-mortem toxicology investigation. Post-mortem specimens may be numerous and can endow some special difficulties compared to clinical specimens, namely those resulting from autolytic and putrefactive changes. Storage stability is also an important issue to be considered during the pre-analytic phase, since its consideration should facilitate the assessment of sample quality and the analytical result obtained from that sample. The knowledge on degradation mechanisms and methods to increase storage stability may enable the forensic toxicologist to circumvent possible difficulties. Therefore, advantages and limitations of specimen preservation procedures are thoroughfully discussed in this review. Presently, harmonized protocols for sampling in suspected intoxications would have obvious utility. In the present article an overview is given on sampling procedures for routinely collected specimens as well as on alternative specimens that may provide additional information on the route and timing of exposure to a specific xenobiotic. Last, but not least, a discussion on possible bias that can influence the interpretation of toxicological results is provided. This comprehensive review article is intented as a significant help for forensic toxicologists to accomplish their frequently overwhelming mission.

  9. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for

  10. The importance of sound methodology in environmental DNA sampling

    Science.gov (United States)

    T. M. Wilcox; K. J. Carim; M. K. Young; K. S. McKelvey; T. W. Franklin; M. K. Schwartz

    2018-01-01

    Environmental DNA (eDNA) sampling - which enables inferences of species’ presence from genetic material in the environment - is a powerful tool for sampling rare fishes. Numerous studies have demonstrated that eDNA sampling generally provides greater probabilities of detection than traditional techniques (e.g., Thomsen et al. 2012; McKelvey et al. 2016; Valentini et al...

  11. Fallout Concentration Various Environmental Samples in Indonesia

    International Nuclear Information System (INIS)

    Sutarman

    2001-01-01

    The testing of nuclear weapons have been carried out by the advanced countries, such as United States, Russian Federation, United Kingdom, France, China, India and Pakistan, since about 1945 until 1998. Nuclear weapons tests were conducted at various locations, on and above the earth's surface or underground or on and under the ocean's surface. Nuclear explosions caused the radionuclides of fission product, such as 131 l, 89 Sr, 90 Sr, 134 Cs, 137 Cs, and 239 Pu released to the atmospheric layer. In the atmospheric layer, the long-lived radionuclides, i.e, 90 Sr dan 137 Cs will be distributed into the environment as the fallout radionuclides, and deposited in the various environmental samples (soil, water, and biota). In general, at several locations in Indonesia the 90 Sr and 137 Cs in the various environmental samples still can be detected. The data of measurement results of 90 Sr and 137 Cs concentrations were generally lower than that from some countries in the northern hemisphere. (author)

  12. k0-INAA for APM samples collected in period of June 2004 - March 2005 and some marine certified reference materials

    International Nuclear Information System (INIS)

    Dung, Ho Manh; Vu, Cao Dong; Y, Truong; Sy, Nguyen Thi

    2006-01-01

    The airborne particulate matter (APM) samples have been collected in 2004 using two types of polycarbonate membrane filter PM 2.5 and PM 2.5-10 at two sites of industrial (Ho Chi Mihn City) and rural (Dateh) regions in south of Vietnam. Three marine certified reference materials have been selected to establish a k0-NAA procedure for marine samples. The concentration of trace multi-element in the samples has been determined by the k 0 -INAA procedure using K o -DALAT software developed in Dalat NRI. About 28 elements in 224 APM samples collected at two areas of Dateh and HCMC of Vietnam in period from June, 2004 to March, 2005 were presented in report. The statistical analysis was applied to the data set to investigate the pollution source at sampling sites. The results proved that the k 0 -NAA on the Dalat research reactor is a reliable and effective analytical technique for characterization of trace multi-element in APM and marine samples for air and marine environmental pollution study in Vietnam. (author)

  13. Tracking pan-continental trends in environmental contamination using sentinel raptors-what types of samples should we use?

    Science.gov (United States)

    Espín, S; García-Fernández, A J; Herzke, D; Shore, R F; van Hattum, B; Martínez-López, E; Coeurdassier, M; Eulaers, I; Fritsch, C; Gómez-Ramírez, P; Jaspers, V L B; Krone, O; Duke, G; Helander, B; Mateo, R; Movalli, P; Sonne, C; van den Brink, N W

    2016-05-01

    Biomonitoring using birds of prey as sentinel species has been mooted as a way to evaluate the success of European Union directives that are designed to protect people and the environment across Europe from industrial contaminants and pesticides. No such pan-European evaluation currently exists. Coordination of such large scale monitoring would require harmonisation across multiple countries of the types of samples collected and analysed-matrices vary in the ease with which they can be collected and the information they provide. We report the first ever pan-European assessment of which raptor samples are collected across Europe and review their suitability for biomonitoring. Currently, some 182 monitoring programmes across 33 European countries collect a variety of raptor samples, and we discuss the relative merits of each for monitoring current priority and emerging compounds. Of the matrices collected, blood and liver are used most extensively for quantifying trends in recent and longer-term contaminant exposure, respectively. These matrices are potentially the most effective for pan-European biomonitoring but are not so widely and frequently collected as others. We found that failed eggs and feathers are the most widely collected samples. Because of this ubiquity, they may provide the best opportunities for widescale biomonitoring, although neither is suitable for all compounds. We advocate piloting pan-European monitoring of selected priority compounds using these matrices and developing read-across approaches to accommodate any effects that trophic pathway and species differences in accumulation may have on our ability to track environmental trends in contaminants.

  14. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    Science.gov (United States)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  15. Wet-digestion of environmental sample using silver-mediated electrochemical method

    International Nuclear Information System (INIS)

    Kuwabara, Jun

    2010-01-01

    An application of silver-mediated electrochemical method to environmental samples as the effective digestion method for iodine analysis was tried. Usual digestion method for 129 I in many type of environmental sample is combustion method using quartz glass tube. Chemical yield of iodine on the combustion method reduce depending on the type of sample. The silver-mediated electrochemical method is expected to achieve very low loss of iodine. In this study, dried kombu (Laminaria) sample was tried to digest with electrochemical cell. At the case of 1g of sample, digestion was completed for about 24 hours under the electric condition of <10V and <2A. After the digestion, oxidized species of iodine was reduced to iodide by adding sodium sulfite. And then the precipitate of silver iodide was obtained. (author)

  16. Environmental radiation monitoring around the nuclear facilities

    International Nuclear Information System (INIS)

    Lee, H.D.; Lee, Y.B.; Lee, W.Y.; Park, D.W.; Chung, B.G.

    1980-01-01

    For the KAERI site, various environmental samples were collected three times a month, and the natural environmental radiation levels were also measured at each sampling point. Measurements for gross alpha and beta radioactivities of the samples were routinely measured for all samples. Strontium-90 concentrations were also analysed for the fallout and air samples collected daily basis on the roof of the main building. Accumulated exposure including the possibility of determination of low level environmental radiation field by employing thermoluminescent dosimeter, CaSO 4 : Dsub(y)-0.4 teflon disc type, at 6 posts in on-site of the KAERI. As for Kori site, at 19 points of ON, OFF-site, and at the same time the environmental radiation exposure rate at each sampling point were measured. Several environmental samples such as surface soil, pine needles, water samples, milk sample and pasture samples were collected and analysed on a quarterly basis. As a result of the survey it can be said that no significant release of radiation to the environment due to the operations of nuclear facilities including research reactor at the KAERI and power reactor at the Kori has been found during the period of the survey and monitoring. (author)

  17. Fluoroquinolone antibiotics in environmental waters: sample preparation and determination.

    Science.gov (United States)

    Speltini, Andrea; Sturini, Michela; Maraschi, Federica; Profumo, Antonella

    2010-04-01

    The aim of this review is to provide a general overview on the analytical methods proposed in the last decade for trace fluoroquinolone (FQ) determination in environmental waters. A large number of studies have been developed on this topic in reason of the importance of their monitoring in the studies of environmental mobility and potential degradation pathways. Every step of the analysis has been carefully considered, with a particular attention to sample preparation, in relationship with the problems involved in the analysis of real matrices. The different strategies to minimise interference from organic matter and to achieve optimal sensitivity, especially important in those samples with lower FQ concentrations, were also highlighted. Results and progress in this field have been described and critically commented. Moreover, a worldwide overview on the presence of FQs in the environmental waters has been reported.

  18. Accuracy and Precision in Elemental Analysis of Environmental Samples using Inductively Coupled Plasma-Atomic Emission Spectrometry

    International Nuclear Information System (INIS)

    Quraishi, Shamsad Begum; Chung, Yong-Sam; Choi, Kwang Soon

    2005-01-01

    Inductively Coupled Plasma-Atomic Emission Spectrometry followed by micro-wave digestion have been performed on different environmental Certified Reference Materials (CRMs). Analytical results show that accuracy and precision in ICP-AES analysis were acceptable and satisfactory in case of soil and hair CRM samples. The relative error of most of the elements in these two CRMs is within 10% with few exceptions and coefficient of variation is also less than 10%. Z-score as an analytical performance was also within the acceptable range (±2). ICP-AES was found as an inadequate method for Air Filter CRM due to incomplete dissolution, low concentration of elements and very low mass of the sample. However, real air filter sample could have been analyzed with high accuracy and precision by increasing sample mass during collection. (author)

  19. Detection of Chlamydophila psittaci from feral pigeons in environmental samples: problems with currently available techniques.

    Science.gov (United States)

    Geigenfeind, Ila; Haag-Wackernagel, Daniel

    2010-03-01

    Chlamydophila psittaci (Lillie, 1930) Everett et al., 1999, the pathogenic agent of human ornithosis, is widespread in feral pigeon populations and many cases of transmission from feral pigeons to humans have been reported. The aim of the present study was to detect C. psittaci in environmental samples to find out more about possible transmission routes and, therefore, to assess the zoonotic risk for humans. Fecal samples were collected from nest boxes in a feral pigeon loft. Additionally, samples were taken from the feather dust film covering the water surface of public fountains where pigeons regularly bathe. The samples were tested for the presence of chlamydial antigen using an antigen enzyme-linked immunosorbent assay to prove shedding of C. psittaci by feral pigeons. This test detects a genus specific lipopolysaccharide in the outer membrane of the chlamydial bacteria. Samples were tested using the IDEIA PCE Chlamydia Test kit (DakoCytomation) and positive results were verified with IDEIA Chlamydia Blocking Reagents (DakoCytomation). The IDEIA PCE Chlamydia Test yields a high proportion of positive results. However, when IDEIA Chlamydia Blocking was performed, most of the positive results turned out to be negative or could not be interpreted. We conclude that antigen-enzyme-linked immunosorbent assay tests are not suitable for detecting C. psittaci in environmental samples. Previous publications where no blocking test was used should be reconsidered critically. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  20. Collection and control of tritium bioassay samples at Pantex

    International Nuclear Information System (INIS)

    Fairrow, N.L.; Ivie, W.E.

    1992-01-01

    Pantex is the final assembly/disassembly point for US nuclear weapons. The Pantex internal dosimetry section monitors radiation workers once a month for tritium exposure. In order to manage collection and control of the bioassay specimens efficiently, a bar code system for collection of samples was developed and implemented to speed up the process and decrease the number of errors probable when transferring data. In the past, all the bioassay data from samples were entered manually into a computer database. Transferring the bioassay data from the liquid scintillation counter to each individual's dosimetry record required as much as two weeks of concentrated effort

  1. Environmental DNA from seawater samples correlate with trawl catches of Subarctic, deepwater fishes

    DEFF Research Database (Denmark)

    Thomsen, Philip Francis; Møller, Peter Rask; Sigsgaard, Eva Egelyng

    2016-01-01

    depths in Southwest Greenland. We collected seawater samples at depths of 188-918 m and compared seawater eDNA to catch data from trawling. We used Illumina sequencing of PCR products to demonstrate that eDNA reads show equivalence to fishing catch data obtained from trawling. Twenty-six families were......Remote polar and deepwater fish faunas are under pressure from ongoing climate change and increasing fishing effort. However, these fish communities are difficult to monitor for logistic and financial reasons. Currently, monitoring of marine fishes largely relies on invasive techniques...... such as bottom trawling, and on official reporting of global catches, which can be unreliable. Thus, there is need for alternative and non-invasive techniques for qualitative and quantitative oceanic fish surveys. Here we report environmental DNA (eDNA) metabarcoding of seawater samples from continental slope...

  2. Determination of /sup 240/Pu//sup 239/Pu ratio in the environmental samples based on the measurement of Lx/. cap alpha. -ray activity ratio

    Energy Technology Data Exchange (ETDEWEB)

    Komura, K.; Sakanoue, M.; Yamamoto, M.

    1984-06-01

    The determination of the /sup 240/Pu//sup 239/Pu isotopic ratio in environmental samples has been attempted by the measurement of the Lx/..cap alpha..-ray activity ratio using a Ge-LEPS (low-energy photon spectrometer) and a surface-barrier Si detector. By this method, interesting data were obtained for various samples collected from Thule, Greenland, Bikini Atoll and Nagasaki, as well as for some soils collected from near and off-site locations of atomic power stations.

  3. Joint sampling programme-Verification of data obtained in environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lauria, D.C. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)], E-mail: dejanira@ird.gov.br; Martins, N.S.F.; Vasconcellos, M.L.H.; Zenaro, R.; Peres, S.S.; Pires do Rio, M.A. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2008-11-15

    The objective of the Environmental Radiological Monitoring Control programme carried out by the Institute of Radiation Protection and Dosimetry (IRD) in Brazil is to verify the licensee's compliance with the requirements for environmental monitoring of Brazilian facilities. The Joint Sampling Programme (JSP) is just one part of the control programme. In order to verify that the data reported by the licensees is representative and legitimate, this programme verifies sampling procedures, accuracy and precision of the data and the changes in the environmental conditions. This paper discusses the main findings of this programme that allowed IRD to optimize its available resources to control the monitoring of the eight facilities in Brazil.

  4. Comparison of DNA preservation methods for environmental bacterial community samples.

    Science.gov (United States)

    Gray, Michael A; Pratte, Zoe A; Kellogg, Christina A

    2013-02-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard(™), RNAlater(®), DMSO-EDTA-salt (DESS), FTA(®) cards, and FTA Elute(®) cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA(®) cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard(™), RNAlater(®), and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  5. Capability of environmental sampling to detect undeclared cask openings

    Energy Technology Data Exchange (ETDEWEB)

    Beckstead, L.W.; Efurd, D.W.; Hemberger, P.H.; Abhold, M.E.; Eccleston, G.W.

    1997-12-01

    The goal of this study is to determine the signatures that would allow monitors to detect diversion of nuclear fuel (by a diverter) from a storage area such as a geological repository. Due to the complexity of operations surrounding disposal of spent nuclear fuel in a geologic repository, there are several places that a diversion of fuel could take place. After the canister that contains the fuel rods is breached, the diverter would require a hot cell to process or repackage the fuel. A reference repository and possible diversion scenarios are discussed. When a canister is breached, or during reprocessing to extract nuclear weapons material (primarily Pu), several important isotopes or signatures including tritium, {sup 85}Kr, and {sup 129}I are released to the surrounding environment and have the potential for analysis. Estimates of release concentrations of the key signatures from the repository under a hypothetical diversion scenario are presented and discussed. Gas analysis data collected from above-ground storage casks at Idaho National Engineering and Environmental Laboratory (INEEL) Test Area North (TAN) are included and discussed in the report. In addition, LANL participated in gas sampling of one TAN cask, the Castor V/21, in July 1997. Results of xenon analysis from the cask gas sample are presented and discussed. The importance of global fallout and recent commercial reprocessing activities and their effects on repository monitoring are discussed. Monitoring and instrumental equipment for analysis of the key signature isotopes are discussed along with limits of detection. A key factor in determining if diversion activities are in progress at a repository is the timeliness of detection and analysis of the signatures. Once a clandestine operation is suspected, analytical data should be collected as quickly as possible to support any evidence of diversion.

  6. Capability of environmental sampling to detect undeclared cask openings

    International Nuclear Information System (INIS)

    Beckstead, L.W.; Efurd, D.W.; Hemberger, P.H.; Abhold, M.E.; Eccleston, G.W.

    1997-01-01

    The goal of this study is to determine the signatures that would allow monitors to detect diversion of nuclear fuel (by a diverter) from a storage area such as a geological repository. Due to the complexity of operations surrounding disposal of spent nuclear fuel in a geologic repository, there are several places that a diversion of fuel could take place. After the canister that contains the fuel rods is breached, the diverter would require a hot cell to process or repackage the fuel. A reference repository and possible diversion scenarios are discussed. When a canister is breached, or during reprocessing to extract nuclear weapons material (primarily Pu), several important isotopes or signatures including tritium, 85 Kr, and 129 I are released to the surrounding environment and have the potential for analysis. Estimates of release concentrations of the key signatures from the repository under a hypothetical diversion scenario are presented and discussed. Gas analysis data collected from above-ground storage casks at Idaho National Engineering and Environmental Laboratory (INEEL) Test Area North (TAN) are included and discussed in the report. In addition, LANL participated in gas sampling of one TAN cask, the Castor V/21, in July 1997. Results of xenon analysis from the cask gas sample are presented and discussed. The importance of global fallout and recent commercial reprocessing activities and their effects on repository monitoring are discussed. Monitoring and instrumental equipment for analysis of the key signature isotopes are discussed along with limits of detection. A key factor in determining if diversion activities are in progress at a repository is the timeliness of detection and analysis of the signatures. Once a clandestine operation is suspected, analytical data should be collected as quickly as possible to support any evidence of diversion

  7. A continuous flow from sample collection to data acceptability determination using an automated system

    International Nuclear Information System (INIS)

    Fisk, J.F.; Leasure, C.; Sauter, A.D.

    1993-01-01

    In its role as regulator, EPA is the recipient of enormous reams of analytical data, especially within the Superfund Program. In order to better manage the volume of paper that comes in daily, Superfund has required its laboratories to provide data that is contained on reporting forms to be delivered also on a diskette for uploading into data bases for various purposes, such as checking for contractual compliance, tracking quality assurance parameters, and, ultimately, for reviewing the data by computer. This last area, automated review of the data, has generated programs that are not necessarily appropriate for use by clients other than Superfund. Such is the case with Los Alamos National Laboratory's Environmental Chemistry Group and its emerging subcontractor community, designed to meet the needs of the remedial action program at LANL. LANL is in the process of implementing an automated system that will be used from the planning stage of sample collection to the production of a project-specific report on analytical data quality. Included are electronic scheduling and tracking of samples, data entry, checking and transmission, data assessment and qualification for use, and report generation that will tie the analytical data quality back to the performance criteria defined prior to sample collection. Industry standard products will be used (e.g., ORACLE, Microsoft Excel) to ensure support for users, prevent dependence on proprietary software, and to protect LANL's investment for the future

  8. Rapid and Automated Determination of Plutonium and Neptunium in Environmental Samples

    DEFF Research Database (Denmark)

    Qiao, Jixin

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development...... and optimization for rapid determination of plutonium in environmental samples using SIextraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples...... for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including...

  9. Biological collections and ecological/environmental research: a review, some observations and a look to the future.

    Science.gov (United States)

    Pyke, Graham H; Ehrlich, Paul R

    2010-05-01

    Housed worldwide, mostly in museums and herbaria, is a vast collection of biological specimens developed over centuries. These biological collections, and associated taxonomic and systematic research, have received considerable long-term public support. The work remaining in systematics has been expanding as the estimated total number of species of organisms on Earth has risen over recent decades, as have estimated numbers of undescribed species. Despite this increasing task, support for taxonomic and systematic research, and biological collections upon which such research is based, has declined over the last 30-40 years, while other areas of biological research have grown considerably, especially those that focus on environmental issues. Reflecting increases in research that deals with ecological questions (e.g. what determines species distribution and abundance) or environmental issues (e.g. toxic pollution), the level of research attempting to use biological collections in museums or herbaria in an ecological/environmental context has risen dramatically during about the last 20 years. The perceived relevance of biological collections, and hence the support they receive, should be enhanced if this trend continues and they are used prominently regarding such environmental issues as anthropogenic loss of biodiversity and associated ecosystem function, global climate change, and decay of the epidemiological environment. It is unclear, however, how best to use biological collections in the context of such ecological/environmental issues or how best to manage collections to facilitate such use. We demonstrate considerable and increasingly realized potential for research based on biological collections to contribute to ecological/environmental understanding. However, because biological collections were not originally intended for use regarding such issues and have inherent biases and limitations, they are proving more useful in some contexts than in others. Biological

  10. Application of ICP-MS in Environmental Sampling Analysis for Safeguards

    International Nuclear Information System (INIS)

    Eko Pudjadi; Petrus Zacharias; Budi Prayitno

    2004-01-01

    Environmental samples measured by ICP-MS were analyzed for safeguards. There are two isotopes in environmental sampling that is used to find out the origin of nuclear materials and verify undeclared nuclear activities. Uranium isotopes are 234 U, 235 U, 236 U and 238 U and Plutonium isotopes are 239 Pu, 240 Pu, 241 Pu and 242 Pu. Uranium isotopes are used to verify an existing of nuclear power plants, enrichment plants or reprocessing plants. Plutonium isotopes are used to clarify global fallout from nuclear weapon testing and accident of nuclear facility or military purposes. The high sensitivity of ICP-MS can detect the isotopic fingerprint and trace elements in ppb concentration; ICP-MS has been applied to measure 235 U isotopic ratio and 240 Pu/ 239 Pu isotopic ratios. The sensitivity of ICP-MS is high precision and low operational cost in environmental sampling and can be considered in nuclear power design based on safeguards for development countries. (author)

  11. Gamma-ray self-attenuation corrections in environmental samples

    International Nuclear Information System (INIS)

    Robu, E.; Giovani, C.

    2009-01-01

    Gamma-spectrometry is a commonly used technique in environmental radioactivity monitoring. Frequently the bulk samples that should be measured differ with respect to composition and density from the reference sample used for efficiency calibration. Correction factors should be applied in these cases for activity measurement. Linear attenuation coefficients and self-absorption correction factors have been evaluated for soil, grass and liquid sources with different densities and geometries.(authors)

  12. Application of the CometChip platform to assess DNA damage in field-collected blood samples from turtles.

    Science.gov (United States)

    Sykora, Peter; Chiari, Ylenia; Heaton, Andrew; Moreno, Nickolas; Glaberman, Scott; Sobol, Robert W

    2018-05-01

    DNA damage has been linked to genomic instability and the progressive breakdown of cellular and organismal homeostasis, leading to the onset of disease and reduced longevity. Insults to DNA from endogenous sources include base deamination, base hydrolysis, base alkylation, and metabolism-induced oxidative damage that can lead to single-strand and double-strand DNA breaks. Alternatively, exposure to environmental pollutants, radiation or ultra-violet light, can also contribute to exogenously derived DNA damage. We previously validated a novel, high through-put approach to measure levels of DNA damage in cultured mammalian cells. This new CometChip Platform builds on the classical single cell gel electrophoresis or comet methodology used extensively in environmental toxicology and molecular biology. We asked whether the CometChip Platform could be used to measure DNA damage in samples derived from environmental field studies. To this end, we determined that nucleated erythrocytes from multiple species of turtle could be successfully evaluated in the CometChip Platform to quantify levels of DNA damage. In total, we compared levels of DNA damage in 40 animals from two species: the box turtle (Terrapene carolina) and the red-eared slider (Trachemys scripta elegans). Endogenous levels of DNA damage were identical between the two species, yet we did discover some sex-linked differences and changes in DNA damage accumulation. Based on these results, we confirm that the CometChip Platform allows for the measurement of DNA damage in a large number of samples quickly and accurately, and is particularly adaptable to environmental studies using field-collected samples. Environ. Mol. Mutagen. 59:322-333, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  13. Infrared characterization of environmental samples by pulsed photothermal spectroscopy

    International Nuclear Information System (INIS)

    Seidel, W.; Foerstendorf, H.; Heise, K.H.; Nicolai, R.; Schamlott, A.; Ortega, J.M.; Glotin, F.; Prazeres, R.

    2004-01-01

    Low concentration of toxic radioactive metals in environmental samples often limits the interpretation of results of infrared studies investigating the interaction processes between the metal ions and environmental compartments. For the first time, we could show that photothermal infrared spectroscopy performed with a pulsed free electron laser can provide reliable infrared spectra throughout a distinct spectral range of interest. In this model investigation, we provide vibrational absorption spectra of a rare earth metal salt dissolved in a KBr matrix and a natural calcite sample obtained by photothermal beam deflection (PTBD) technique and FT-IR (Fourier-transform infrared) spectroscopy, respectively. General agreement was found between all spectra of the different recording techniques. Spectral deviations were observed with samples containing low concentration of the rare earth metal salt indicating a lower detection limit of the photothermal method as compared to conventional FT-IR spectroscopy. (authors)

  14. Qualitative and quantitative analysis of environmental samples by laser-induced breakdown spectrometry

    International Nuclear Information System (INIS)

    Zorov, N B; Popov, A M; Zaytsev, S M; Labutin, T A

    2015-01-01

    The key achievements in the determination of trace amounts of components in environmental samples (soils, ores, natural waters, etc.) by laser-induced breakdown spectrometry are considered. Unique capabilities of this method make it suitable for rapid analysis of metals and alloys, glasses, polymers, objects of cultural heritage, archaeological and various environmental samples. The key advantages of the method that account for its high efficiency are demonstrated, in particular, a small amount of analyzed material, the absence of sample preparation, the possibility of local and remote analysis of either one or several elements. The use of chemometrics in laser-induced breakdown spectrometry for qualitative sample classification is described in detail. Various approaches to improving the figures of merit of quantitative analysis of environmental samples are discussed. The achieved limits of detection for most elements in geochemical samples are critically evaluated. The bibliography includes 302 references

  15. Rapid and automated determination of plutonium and neptunium in environmental samples

    International Nuclear Information System (INIS)

    Qiao, J.

    2011-03-01

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242 Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  16. Rapid and automated determination of plutonium and neptunium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Qiao, J.

    2011-03-15

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  17. Analysis procedure for americium in environmental samples

    International Nuclear Information System (INIS)

    Holloway, R.W.; Hayes, D.W.

    1982-01-01

    Several methods for the analysis of 241 Am in environmental samples were evaluated and a preferred method was selected. This method was modified and used to determine the 241 Am content in sediments, biota, and water. The advantages and limitations of the method are discussed. The method is also suitable for 244 Cm analysis

  18. Metagenomic covariation along densely sampled environmental gradients in the Red Sea

    KAUST Repository

    Thompson, Luke R

    2016-07-15

    Oceanic microbial diversity covaries with physicochemical parameters. Temperature, for example, explains approximately half of global variation in surface taxonomic abundance. It is unknown, however, whether covariation patterns hold over narrower parameter gradients and spatial scales, and extending to mesopelagic depths. We collected and sequenced 45 epipelagic and mesopelagic microbial metagenomes on a meridional transect through the eastern Red Sea. We asked which environmental parameters explain the most variation in relative abundances of taxonomic groups, gene ortholog groups, and pathways—at a spatial scale of <2000 km, along narrow but well-defined latitudinal and depth-dependent gradients. We also asked how microbes are adapted to gradients and extremes in irradiance, temperature, salinity, and nutrients, examining the responses of individual gene ortholog groups to these parameters. Functional and taxonomic metrics were equally well explained (75–79%) by environmental parameters. However, only functional and not taxonomic covariation patterns were conserved when comparing with an intruding water mass with different physicochemical properties. Temperature explained the most variation in each metric, followed by nitrate, chlorophyll, phosphate, and salinity. That nitrate explained more variation than phosphate suggested nitrogen limitation, consistent with low surface N:P ratios. Covariation of gene ortholog groups with environmental parameters revealed patterns of functional adaptation to the challenging Red Sea environment: high irradiance, temperature, salinity, and low nutrients. Nutrient-acquisition gene ortholog groups were anti-correlated with concentrations of their respective nutrient species, recapturing trends previously observed across much larger distances and environmental gradients. This dataset of metagenomic covariation along densely sampled environmental gradients includes online data exploration supplements, serving as a community

  19. Measurements of plutonium in environmental samples

    International Nuclear Information System (INIS)

    D'Alberti, F.; Risposi, L.

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961

  20. Measurements of plutonium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    D' Alberti, F; Risposi, L [Instituto di Fisica Applicata, University of Milan, Milan (Italy)

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961.

  1. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    Science.gov (United States)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  2. Hanford Site Environmental Surveillance Data Report for Calendar Year 2002

    International Nuclear Information System (INIS)

    Bisping, Lynn E.

    2003-01-01

    This data report contains the actual raw data used in the annual Hanford Site environmental report (PNNL--14295). In addition to providing raw data collected during routine sampling in 2002, this report also includes data from special sampling studies performed by PNNL during 2002. Environmental surveillance at the Hanford Site, located in southeastern Washington State, is conducted by Pacific Northwest National Laboratory (PNNL), which is operated by Battelle for the U.S. Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals and metals in Columbia River water and sediment. For more information regarding the 2002 sampling schedule for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project, refer to L. E. Bisping, Environmental Surveillance Master Sampling Schedule (PNNL--13418, Pacific Northwest National Laboratory, Richland, Washington). PNNL publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 2002 describes the site mission and activities, general environmental features, radiological and chemical releases from operations, status of compliance with environmental regulations, status of programs to accomplish compliance, and environmental monitoring activities and results. Sections of the annual environmental report include tables and summaries of offsite and onsite environmental surveillance data collected by PNNL during 2002. This data report contains the actual raw data used to create those tables and summaries. In addition to providing raw data collected during routine sampling efforts in 2002, this data report also includes data from special sampling studies performed by PNNL during 2002

  3. ICP-MS applications for the analysis of geological materials and environmental samples

    International Nuclear Information System (INIS)

    Bendl, J.

    1997-01-01

    This work deals with applications of inductively coupled plasma - mass spectrometry applications for the analysis of geological materials and environmental samples. There are instrumentation, calibration, alternatives of sample introduction, interferences, trace elements analysis, rare earth elements and uranium and thorium, precious metals, isotopic analysis and environmental analysis discussed

  4. Onondaga Lake: A Forsaken Superfund Site, or a Sampling Playground for Environmental Geochemistry Classes?

    Science.gov (United States)

    Karmosky, C. C.; Harpp, K. S.

    2004-05-01

    Onondaga Lake, in Syracuse, NY, is described by the EPA as one of the most polluted lakes in the US. High levels of heavy metal and semi-volatile organic contamination provide an excellent case study that serves as the cornerstone for an environmental geochemistry course at Colgate University. Our course is designed to teach students basic environmental analysis skills including experimental design, sample preparation, analytical instrumentation operation, data processing and statistical analysis, and preparation of a collaborative scientific paper. Participating students generally have some background in environmental geology, but rarely more than one semester of chemistry. The Onondaga Lake project is the focus of the course for approximately half the semester. At the outset of the project, students are presented with a driving question that is answered through a series of guided field and lab investigations, such as an assessment of the environmental consequences of a proposed marina along the lakefront. The students' first task is to delve into the lake's environmental history, including identification of contaminants, location of point and non-point pollution sources, and clean-up efforts. Students then participate in 2 field trips to the site. First, students learn the geography of the lake system, collect sediment and water samples, and observe mitigation efforts at the wastewater treatment plant. The second trip is 2-3 weeks later, after students have assessed further sampling needs. Identification and quantification of organic compounds are accomplished by GC-MS, and heavy metal contents are determined by ICP-MS. Students compile their results, perform statistical analyses, and collaboratively draw their conclusions regarding the impact of the proposed project. The final product is a single report written by the entire class, an exercise in organization, cooperation, and planning that is usually the most challenging, but ultimately the most rewarding

  5. Physical sampling for site and waste characterization

    International Nuclear Information System (INIS)

    Bonnough, T.L.

    1994-01-01

    Physical sampling plays a basic role in site and waste characterization program effort. The term ''physical sampling'' used here means collecting tangible, physical samples of soil, water, air, waste streams, or other materials. The industry defines the term ''physical sampling'' broadly to include measurements of physical conditions such as temperature, wind conditions, and pH which are also often taken in a sample collection effort. Most environmental compliance actions are supported by the results of taking, recording, and analyzing physical samples and the measuring of physical conditions taken in association with sample collecting

  6. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  7. Nuclear analytical techniques and their application to environmental samples

    International Nuclear Information System (INIS)

    Lieser, K.H.

    1986-01-01

    A survey is given on nuclear analytical techniques and their application to environmental samples. Measurement of the inherent radioactivity of elements or radionuclides allows determination of natural radioelements (e.g. Ra), man-made radioelements (e.g. Pu) and radionuclides in the environment. Activation analysis, in particular instrumental neutron activation analysis, is a very reliable and sensitive method for determination of a great number of trace elements in environmental samples, because the most abundant main constituents are not activated. Tracer techniques are very useful for studies of the behaviour and of chemical reactions of trace elements and compounds in the environment. Radioactive sources are mainly applied for excitation of characteristic X-rays (X-ray fluorescence analysis). (author)

  8. A 'feather-trap' for collecting DNA samples from birds.

    Science.gov (United States)

    Maurer, Golo; Beck, Nadeena; Double, Michael C

    2010-01-01

    Genetic analyses of birds are usually based on DNA extracted from a blood sample. For some species, however, obtaining blood samples is difficult because they are sensitive to handling, pose a conservation or animal welfare concern, or evade capture. In such cases, feathers obtained from live birds in the wild can provide an alternative source of DNA. Here, we provide the first description and evaluation of a 'feather-trap', consisting of small strips of double-sided adhesive tape placed close to a nest with chicks, as a simple, inexpensive and minimally invasive method to collect feathers. The feather-trap was tested in tropical conditions on the Australian pheasant coucal (Centropus phasianinus). None of the 12 pairs of coucals on which the feather-trap was used abandoned the nest, and feeding rates did not differ from those of birds not exposed to a feather-trap. On average, 4.2 feathers were collected per trap over 2-5 days and, despite exposure to monsoonal rain, DNA was extracted from 71.4% of samples, albeit at low concentrations. The amount of genomic DNA extracted from each feather was sufficient to reliably genotype individuals at up to five microsatellite loci for parentage analysis. We show that a feather-trap can provide a reliable alternative for obtaining DNA in species where taking blood is difficult. It may also prove useful for collecting feather samples for other purposes, e.g. stable-isotope analysis. © 2009 Blackwell Publishing Ltd.

  9. Radiation Target Area Sample Environmental Chamber (RTASEC), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Payload Systems Inc. proposes the Radiation Target Area Sample Environmental Chamber (RTASEC) as an innovative approach enabling radiobiologists to investigate the...

  10. Surface Environmental Surveillance Procedures Manual

    International Nuclear Information System (INIS)

    Hanf, Robert W.; Poston, Ted M.

    2000-01-01

    Shows and explains certain procedures needed for surface environmental surveillance. Hanford Site environmental surveillance is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) under the Surface Environmental Surveillance Project (SESP). The basic requirements for site surveillance are set fourth in DOE Order 5400.1, General Environmental Protection Program Requirements. Guidance for the SESP is provided in DOE Order 5484.1, Environmental Protection, Safety, and Health Protection Information Reporting Requirements and DOE Order 5400.5, Radiation Protection of the Public and Environment. Guidelines for environmental surveillance activities are provided in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance. An environmental monitoring plan for the Hanford Site is outlined in DOE/RL 91-50 Rev. 2, Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual. Personnel training requirements are documented in SESP-TP-01 Rev.2, Surface Environmental Surveillance Project Training Program.

  11. Technical Note: New methodology for measuring viscosities in small volumes characteristic of environmental chamber particle samples

    Directory of Open Access Journals (Sweden)

    L. Renbaum-Wolff

    2013-01-01

    Full Text Available Herein, a method for the determination of viscosities of small sample volumes is introduced, with important implications for the viscosity determination of particle samples from environmental chambers (used to simulate atmospheric conditions. The amount of sample needed is < 1 μl, and the technique is capable of determining viscosities (η ranging between 10−3 and 103 Pascal seconds (Pa s in samples that cover a range of chemical properties and with real-time relative humidity and temperature control; hence, the technique should be well-suited for determining the viscosities, under atmospherically relevant conditions, of particles collected from environmental chambers. In this technique, supermicron particles are first deposited on an inert hydrophobic substrate. Then, insoluble beads (~1 μm in diameter are embedded in the particles. Next, a flow of gas is introduced over the particles, which generates a shear stress on the particle surfaces. The sample responds to this shear stress by generating internal circulations, which are quantified with an optical microscope by monitoring the movement of the beads. The rate of internal circulation is shown to be a function of particle viscosity but independent of the particle material for a wide range of organic and organic-water samples. A calibration curve is constructed from the experimental data that relates the rate of internal circulation to particle viscosity, and this calibration curve is successfully used to predict viscosities in multicomponent organic mixtures.

  12. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  13. Biopolymers for Sample Collection, Protection, and Preservation

    Science.gov (United States)

    2015-05-19

    knowledge of sample collection from various matrices is crucial. Recovery and preservation of microorganisms prior to analysis are important...Another method for encapsulating bacteria for use in biodegradation of gasoline involves a complex process using gellan gum (Moslemy et al. 2002). Many...use of acacia gum in preserving microorganisms for extended periods of time without refrigeration (Krumnow et al. 2009; Sorokulova et al. 2008, 2012

  14. Distribution of {sup 90}Sr activities in the environmental radiation samples of Jeju Island, Korea

    Energy Technology Data Exchange (ETDEWEB)

    Han, Chung Hun; Park, Youn Hyun; Lee, Young Gyu; Park, Jae Woo [Jeju National University, Jeju (Korea, Republic of)

    2016-12-15

    This work was to get information about {sup 90}Sr contamination of the environment by using soil and moss from selected areas in Jeju Island, Korea. The activities of {sup 90}Sr in soil and moss samples were investigated at nine locations of Jeju island, Korea. The soil samples have been collected at 4 sites of Jeju island during June to August of 2013, analyzed for vertical distribution of {sup 90}Sr activities. The moss samples have been collected at 5 sites of Jeju island during November of 2011 to June of 2012, and analyzed for radioactive {sup 90}Sr. The {sup 90}Sr vertical concentrations in the investigated soil samples were 2.77 to 18.24 Bq·kg{sup -1} in eastern part, 1.69 to 18.27 Bq·kg{sup -1} in northern part, 3.76 to 13.46 Bq·kg{sup -1} in the western part and 1.09 to 8.70 Bq·kg{sup -1} in the southern part of the Mt. Halla in Jeju island, respectively. Activities of {sup 90}Sr show the highest value at the surface soil and decrease with depth. The activity concentration measured was in the range of 79.6 to 363 Bq·kg{sup -1} -dry moss. This material is expected to be basis reference for survey of environmental radioactivity in Jeju Island.

  15. The application of x-ray fluorescence and diffraction to the characterization of environmental assessment samples

    International Nuclear Information System (INIS)

    Censullo, A.C.; Briden, F.E.

    1982-01-01

    Some of the results of tests on environmental assessment samples are reported on. The utility of the J.W. Criss fundamental parameters computer program is evaluated for samples in which only one standard per element was used and where the standard matrix did not strictly resemble the unknown matrix. The environmental significance of a sample is dependent not only on its elemental composition, but also on the species or phases which the elements comprise. X-ray powder diffraction may be used to advantage for speciation. Multi-phase environmental assessment samples are amenable to XRD interpretation. Some results of the application of the Joint Committee on Power Diffraction Standards computer interpretatin of typical environmental samples are discussed. They were shown to contribute to the specification of the complex samples that are encountered in environmental assessments

  16. Importance of sampling frequency when collecting diatoms

    KAUST Repository

    Wu, Naicheng

    2016-11-14

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected and analyzed daily riverine diatom samples over a 1-year period (25 April 2013–30 April 2014) at the outlet of a German lowland river. The samples were classified into five clusters (1–5) by a Kohonen Self-Organizing Map (SOM) method based on similarity between species compositions over time. ASFs were determined to be 25 days at Cluster 2 (June-July 2013) and 13 days at Cluster 5 (February-April 2014), whereas no specific ASFs were found at Cluster 1 (April-May 2013), 3 (August-November 2013) (>30 days) and Cluster 4 (December 2013 - January 2014) (<1 day). ASFs showed dramatic seasonality and were negatively related to hydrological wetness conditions, suggesting that sampling interval should be reduced with increasing catchment wetness. A key implication of our findings for freshwater management is that long-term bio-monitoring protocols should be developed with the knowledge of tracking algal temporal dynamics with an appropriate sampling frequency.

  17. A case study of packaging waste collection systems in Portugal - Part II: Environmental and economic analysis.

    Science.gov (United States)

    Pires, Ana; Sargedas, João; Miguel, Mécia; Pina, Joaquim; Martinho, Graça

    2017-03-01

    An understanding of the environmental impacts and costs related to waste collection is needed to ensure that existing waste collection schemes are the most appropriate with regard to both environment and cost. This paper is Part II of a three-part study of a mixed packaging waste collection system (curbside plus bring collection). Here, the mixed collection system is compared to an exclusive curbside system and an exclusive bring system. The scenarios were assessed using life cycle assessment and an assessment of costs to the waste management company. The analysis focuses on the collection itself so as to be relevant to waste managers and decision-makers who are involved only in this step of the packaging life cycle. The results show that the bring system has lower environmental impacts and lower economic costs, and is capable of reducing the environmental impacts of the mixed system. However, a sensitivity analysis shows that these results could differ if the curbside collection were to be optimized. From economic and environmental perspectives, the mixed system has few advantages. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Radionuclides, Metals, and Hydrocarbons in Oil and Gas Operational Discharges and Environmental Samples Associated with Offshore Production Facilities on the Texas/Louisiana Continental Shelf with an Environmental Assessment of Metals and Hydrocarbons

    International Nuclear Information System (INIS)

    1997-06-01

    This report presents concentrations of radionuclides, metals, and hydrocarbons in samples of produced water and produced sand from oil and gas production platforms located offshore Texas and Louisiana. concentrations in produced water discharge plume / receiving water, ambient seawater, sediment, interstitial water, and marine animal tissue samples collected in the vicinity of discharging platforms and reference sites distant from discharges are also reported and discussed. An environmental risk assessment is made on the basis of the concentration of metals and hydrocarbons determined in the samples

  19. Radionuclides, Metals, and Hydrocarbons in Oil and Gas Operational Discharges and Environmental Samples Associated with Offshore Production Facilities on the Texas/Louisiana Continental Shelf with an Environmental Assessment of Metals and Hydrocarbons.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This report presents concentrations of radionuclides, metals, and hydrocarbons in samples of produced water and produced sand from oil and gas production platforms located offshore Texas and Louisiana. concentrations in produced water discharge plume / receiving water, ambient seawater, sediment, interstitial water, and marine animal tissue samples collected in the vicinity of discharging platforms and reference sites distant from discharges are also reported and discussed. An environmental risk assessment is made on the basis of the concentration of metals and hydrocarbons determined in the samples.

  20. Radionuclides, Metals, and Hydrocarbons in Oil and Gas Operational Discharges and Environmental Samples Associated with Offshore Production Facilities on the Texas/Louisiana Continental Shelf with an Environmental Assessment of Metals and Hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Continental Shelf Associates, Inc.

    1999-08-16

    This report presents concentrations of radionuclides, metals, and hydrocarbons in samples of produced water and produced sand from oil and gas production platforms located offshore Texas and Louisiana. Concentrations in produced water discharge plume/receiving water, ambient seawater, sediment, interstitial water, and marine animal tissue samples collected in the vicinity of discharging platforms and reference sites distant from discharges are also reported and discussed. An environmental risk assessment is made on the basis of the concentrations of metals and hydrocarbons determined in the samples.

  1. Determination of uranium and its isotopic ratios in environmental samples

    International Nuclear Information System (INIS)

    Flues Szeles, M.S.M.

    1990-01-01

    A method for the determination of uranium and its isotopic ratios ( sup(235)U/ sup(238)U and sup(234U/ sup(238)U) is established in the present work. The method can be applied in environmental monitoring programs of uranium enrichment facilities. The proposed method is based on the alpha spectrometry technique which is applied after a purification of the sample by using an ionic exchange resin. The total yield achieved was (91 + 5)% with a precision of 5%, an accuracy of 8% and a lower limit of detection of 7,9 x 10 sup(-4)Bq. The uranium determination in samples containing high concentration of iron, which is an interfering element present in environmental samples, particularly in soil and sediment, was also studied. The results obtained by using artificial samples containing iron and uranium in the ratio 1000:1, were considered satisfactory. (author)

  2. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  3. Environmental Monitoring Plan, Revision 6

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, G M; Bertoldo, N A; Blake, R G; Campbell, C G; Grayson, A R; Nelson, J C; Revelli, M A; Rosene, C A; Wegrecki, T; Williams, R A; Wilson, K R; Jones, H E

    2012-03-02

    The purpose of environmental monitoring is to promote the early identification of, and response to, potential adverse environmental impacts associated with Lawrence Livermore National Laboratory (LLNL) operations. Environmental monitoring supports the Integrated Safety Management System (ISMS), International Organization for Standardization (ISO) 14001 Environmental Management Systems standard, and U. S. Department of Energy (DOE) Order 458.1, Radiation Protection of the Public and the Environment. Specifically, environmental monitoring enables LLNL to detect, characterize, and respond to releases from LLNL activities; assess impacts; estimate dispersal patterns in the environment; characterize the pathways of exposure to members of the public; characterize the exposures and doses to individuals and to the population; and to evaluate the potential impacts to the biota in the vicinity of LLNL. Environmental monitoring is also a major component of compliance demonstration for permits and other regulatory requirements. The Environmental Monitoring Plan (EMP) addresses the sample collection and analytical work supporting environmental monitoring to ensure the following: (1) A consistent system for collecting, assessing, and documenting environmental data of known and documented quality; (2) A validated and consistent approach for sampling and analysis of samples to ensure laboratory data meets program-specific needs and requirements within the framework of a performance-based approach for analytical laboratory work; and (3) An integrated sampling approach to avoid duplicative data collection. LLNL prepares the EMP because it provides an organizational framework for ensuring that environmental monitoring work, which is integral to the implementation of LLNL's Environmental Management System, is conducted appropriately. Furthermore, the Environmental Monitoring Plan helps LLNL ensure compliance with DOE Order 231.1 Change 2, Environment, Safety and Health Reporting

  4. Active Collection of Land Cover Sample Data from Geo-Tagged Web Texts

    Directory of Open Access Journals (Sweden)

    Dongyang Hou

    2015-05-01

    Full Text Available Sample data plays an important role in land cover (LC map validation. Traditionally, they are collected through field survey or image interpretation, either of which is costly, labor-intensive and time-consuming. In recent years, massive geo-tagged texts are emerging on the web and they contain valuable information for LC map validation. However, this kind of special textual data has seldom been analyzed and used for supporting LC map validation. This paper examines the potential of geo-tagged web texts as a new cost-free sample data source to assist LC map validation and proposes an active data collection approach. The proposed approach uses a customized deep web crawler to search for geo-tagged web texts based on land cover-related keywords and string-based rules matching. A data transformation based on buffer analysis is then performed to convert the collected web texts into LC sample data. Using three provinces and three municipalities directly under the Central Government in China as study areas, geo-tagged web texts were collected to validate artificial surface class of China’s 30-meter global land cover datasets (GlobeLand30-2010. A total of 6283 geo-tagged web texts were collected at a speed of 0.58 texts per second. The collected texts about built-up areas were transformed into sample data. User’s accuracy of 82.2% was achieved, which is close to that derived from formal expert validation. The preliminary results show that geo-tagged web texts are valuable ancillary data for LC map validation and the proposed approach can improve the efficiency of sample data collection.

  5. Methods to characterize environmental settings of stream and groundwater sampling sites for National Water-Quality Assessment

    Science.gov (United States)

    Nakagaki, Naomi; Hitt, Kerie J.; Price, Curtis V.; Falcone, James A.

    2012-01-01

    Characterization of natural and anthropogenic features that define the environmental settings of sampling sites for streams and groundwater, including drainage basins and groundwater study areas, is an essential component of water-quality and ecological investigations being conducted as part of the U.S. Geological Survey's National Water-Quality Assessment program. Quantitative characterization of environmental settings, combined with physical, chemical, and biological data collected at sampling sites, contributes to understanding the status of, and influences on, water-quality and ecological conditions. To support studies for the National Water-Quality Assessment program, a geographic information system (GIS) was used to develop a standard set of methods to consistently characterize the sites, drainage basins, and groundwater study areas across the nation. This report describes three methods used for characterization-simple overlay, area-weighted areal interpolation, and land-cover-weighted areal interpolation-and their appropriate applications to geographic analyses that have different objectives and data constraints. In addition, this document records the GIS thematic datasets that are used for the Program's national design and data analyses.

  6. PIXE - Analysis for environmental and biological samples

    International Nuclear Information System (INIS)

    Baptista, G.B.

    1980-04-01

    The usefulness and accuracy of PIXE as an analytical tool in the study of trace elements in environmental samples of the Brazilian Cerrado are discussed. The report lists actual and forthcoming publications resulting from the study. The mechanism of exchange of elements in solution in water to aerosols has been investigated. For details of the procedure the reader is referred to an earlier report

  7. Antimicrobial Susceptibility Patterns of Environmental Streptococci Recovered from Bovine Milk Samples in the Maritime Provinces of Canada

    Directory of Open Access Journals (Sweden)

    Marguerite Cameron

    2016-09-01

    Full Text Available Determination of antimicrobial susceptibility of bovine mastitis pathogens is important for guiding antimicrobial treatment decisions and for the detection of emerging resistance. Environmental streptococci are ubiquitous in the farm environment and are a frequent cause of mastitis in dairy cows. The aim of the study was to determine patterns of antimicrobial susceptibility among species of environmental streptococci isolated from dairy cows in the Maritime Provinces of Canada. The collection consisted of 192 isolates identified in milk samples collected from 177 cows originating from 18 dairy herds. Results were aggregated into: 1 Streptococcus uberis (n = 70, 2 Streptococcus dysgalactiae (n = 28, 3 other Streptococci spp. (n = 35, 4, Lactococcus spp. (n = 32, and 5 Enterococcus spp. (n = 27. Minimum inhibitory concentrations (MIC were determined using the Sensititre microdilution system and mastitis plate format. Multilevel logistic regression models were used to analyze the data, with antimicrobial susceptibility as the outcome. The proportion of susceptible Streptococcus uberis ranged from 23% (for penicillin to 99% (for penicillin/novobiocin, with a median of 82%. All Streptococcus dysgalactiae were susceptible to all antimicrobials except for penicillin (93% susceptible and tetracycline (18% susceptible. The range of susceptibility for other Streptococcus spp. was 43% (for tetracycline to 100%, with a median percent susceptibility of 92%. Lactococcus spp. isolates displayed percent susceptibilities ranging from 0% (for penicillin to 97% (for erythromycin, median 75%. For the antimicrobials tested, the MIC were higher for Enterococcus spp. than for the other species. According to the multilevel models, there was a significant interaction between antimicrobial and bacterial species, indicating that susceptibility against a particular antimicrobial varied among the species of environmental streptococci and vice versa. Generally

  8. Collection and preparation of wet and dry stream-sediment samples

    International Nuclear Information System (INIS)

    Puchlik, K.

    1977-03-01

    Lawrence Livermore Laboratory is responsible for the Hydrogeochemistry and Stream Sediment Reconnaissance (HSSR) program for uranium in the seven far western states. The work thus far has concentrated on the arid to semi-arid regions of the West and this paper discusses the collection and preparation of sediment samples in the Basin and Range province. The sample collection and preparation procedures described here may not be applicable to other parts of the far western states or other areas. These procedures also differ somewhat from those used by the other three laboratories involved in the HSSR program

  9. Environmental chemical data for perishable sediments and soils collected in New Orleans, Louisiana, and along the Louisiana Delta following Hurricanes Katrina and Rita, 2005

    Science.gov (United States)

    Witt, Emitt C.; Shi, Honglan; Karstensen, Krista A.; Wang, Jianmin; Adams, Craig D.

    2008-01-01

    In October 2005, nearly one month after Hurricanes Katrina and Rita, a team of scientists from the U.S. Geological Survey and the Missouri University of Science and Technology deployed to southern Louisiana to collect perishable environmental data resulting from the impacts of these storms. Perishable samples collected for this investigation are subject to destruction or ruin by removal, mixing, or natural decay; therefore, collection is time-critical following the depositional event. A total of 238 samples of sediment, soil, and vegetation were collected to characterize chemical quality. For this analysis, 157 of the 238 samples were used to characterize trace element, iron, total organic carbon, pesticide, and polychlorinated biphenyl concentrations of deposited sediment and associated shallow soils. In decreasing order, the largest variability in trace element concentration was detected for lead, vanadium, chromium, copper, arsenic, cadmium, and mercury. Lead was determined to be the trace element of most concern because of the large concentrations present in the samples ranging from 4.50 to 551 milligrams per kilogram (mg/kg). Sequential extraction analysis of lead indicate that 39.1 percent of the total lead concentration in post-hurricane sediment is associated with the iron-manganese oxide fraction. This fraction is considered extremely mobile under reducing environmental conditions, thereby making lead a potential health hazard. The presence of lead in post-hurricane sediments likely is from redistribution of pre-hurricane contaminated soils and sediments from Lake Pontchartrain and the flood control canals of New Orleans. Arsenic concentrations ranged from 0.84 to 49.1 mg/kg. Although Arsenic concentrations generally were small and consistent with other research results, all samples exceeded the U.S. Environmental Protection Agency’s Human Health Medium-Specific Screening Level of 0.39 mg/kg. Mercury concentrations ranged from 0.02 to 1.30 mg

  10. atpE gene as a new useful specific molecular target to quantify Mycobacterium in environmental samples

    Science.gov (United States)

    2013-01-01

    Background The environment is the likely source of many pathogenic mycobacterial species but detection of mycobacteria by bacteriological tools is generally difficult and time-consuming. Consequently, several molecular targets based on the sequences of housekeeping genes, non-functional RNA and structural ribosomal RNAs have been proposed for the detection and identification of mycobacteria in clinical or environmental samples. While certain of these targets were proposed as specific for this genus, most are prone to false positive results in complex environmental samples that include related, but distinct, bacterial genera. Nowadays the increased number of sequenced genomes and the availability of software for genomic comparison provide tools to develop novel, mycobacteria-specific targets, and the associated molecular probes and primers. Consequently, we conducted an in silico search for proteins exclusive to Mycobacterium spp. genomes in order to design sensitive and specific molecular targets. Results Among the 3989 predicted proteins from M. tuberculosis H37Rv, only 11 proteins showed 80% to 100% of similarity with Mycobacterium spp. genomes, and less than 50% of similarity with genomes of closely related Corynebacterium, Nocardia and Rhodococcus genera. Based on DNA sequence alignments, we designed primer pairs and a probe that specifically detect the atpE gene of mycobacteria, as verified by quantitative real-time PCR on a collection of mycobacteria and non-mycobacterial species. The real-time PCR method we developed was successfully used to detect mycobacteria in tap water and lake samples. Conclusions The results indicate that this real-time PCR method targeting the atpE gene can serve for highly specific detection and precise quantification of Mycobacterium spp. in environmental samples. PMID:24299240

  11. Microbial Indicator Profiling of Fresh Produce and Environmental Samples from Farms and Packing Facilities in Northern Mexico.

    Science.gov (United States)

    Heredia, Norma; Caballero, Cindy; Cárdenas, Carmen; Molina, Karina; García, Rafael; Solís, Luisa; Burrowes, Vanessa; Bartz, Faith E; de Aceituno, Anna Fabiszewski; Jaykus, Lee-Ann; García, Santos; Leon, Juan

    2016-07-01

    To compare microbiological indicator and pathogen contamination among different types of fresh produce and environmental samples along the production chain, 636 samples of produce (rinsates from cantaloupe melons, jalapeño peppers, and tomatoes) and environmental samples (rinsates from hands of workers, soil, and water) were collected at four successive steps in the production process (from the field before harvest through the packing facility) on 11 farms in northern Mexico during 2011 and 2012. Samples were assayed for enteric pathogens (Escherichia coli O157:H7, other Shiga toxigenic E. coli, Salmonella, and Listeria monocytogenes) and microbial indicators (coliforms, other E. coli strains, and Enterococcus spp.). Salmonella was the only pathogen detected; it was found in one preharvest jalapeño sample (detection limits: 0.0033 CFU/ml in produce and hand samples, 0.0013 CFU/ml in water, and 0.04 CFU/g in soil). Microbial indicator profiles for produce, worker hands, and soil from jalapeño and tomato farms were similar, but cantaloupe farm samples had higher indicator levels (P soil (indicators were significantly more prevalent (70 to 89% of samples were positive; P = 0.01 to 0.02), and geometric mean levels were higher (0.3 to 0.6 log CFU/100 ml) than those in cantaloupe farm water (32 to 38% of samples were positive, geometric mean indicators were present during all production steps, but prevalence and levels were generally highest at the final on-farm production step (the packing facility) (P type and production step can inform the design of effective approaches to mitigate microbial contamination.

  12. Empirical insights and considerations for the OBT inter-laboratory comparison of environmental samples

    International Nuclear Information System (INIS)

    Kim, Sang-Bog; Roche, Jennifer

    2013-01-01

    Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. -- Highlights: ► Inter-laboratory OBT comparisons would provide a good opportunity for developing reference OBT analytical procedures. ► The measurement of environmental OBT concentrations has a higher associated uncertainty. ► Certified reference materials for OBT in environmental samples are required

  13. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Paducah Gaseous Diffusion Plant Annual Site Environmental Report for 1993

    International Nuclear Information System (INIS)

    1994-10-01

    The purpose of this document is to summarize effluent monitoring and environmental surveillance results and compliance with environmental laws, regulations, and orders at the Paducah Gaseous Diffusion Plant (PGDP). Environmental monitoring at PGDP consists of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring is direct measurement or the collection and analysis of samples of liquid and gaseous discharges to the environment. Environmental surveillance is direct measurement or the collection and analysis of samples of air, water, soil, foodstuff, biota, and other media. Environmental monitoring is performed to characterize and quantify contaminants, assess radiation exposures of members of the public, demonstrate compliance with applicable standards and permit requirements, and detect and assess the effects (if any) on the local environment. Multiple samples are collected throughout the year and are analyzed for radioactivity, chemical content, and various physical attributes

  15. Physical sampling for site and waste characterization

    International Nuclear Information System (INIS)

    Bonnough, T.L.

    1996-01-01

    Physical sampling plays a basic role in high-level radioactive waste management program effort. The term ''physical sampling'' used here means collecting tangible, physical samples of soil, water, air, waste streams, or other materials. The industry defines the term ''physical sampling'' broadly to include measurements of physical conditions such as temperature, wind conditions, and pH, which are also often taken in a sample collection effort. Most environmental compliance actions are supported by the results of taking, recording, and analyzing physical samples and the measurements of physical conditions taken in association with sample collecting. Therefore, the when and how to take samples is needed to be known and planned

  16. Compendium of Environmental Sustainability Indicator Collections: 2006 National Footprint Accounts (NFA)

    Data.gov (United States)

    National Aeronautics and Space Administration — The 2006 National Footprint Accounts (NFA) portion of the Compendium of Environmental Sustainability Indicator Collections, version 1.1 is a data set that measures...

  17. Studies on application of neutron activation analysis -Applied research on air pollution monitoring and development of analytical method of environmental samples

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Chung, Young Ju; Jeong, Eui Sik; Lee, Sang Mi; Kang, Sang Hun; Cho, Seung Yeon; Kwon, Young Sik; Chung, Sang Wuk; Lee, Kyu Sung; Chun, Ki Hong; Kim, Nak Bae; Lee, Kil Yong; Yoon, Yoon Yeol; Chun, Sang Ki.

    1997-09-01

    This research report is written for results of applied research on air pollution monitoring using instrumental neutron activation analysis. For identification and standardization of analytical method, 24 environmental samples are analyzed quantitatively, and accuracy and precision of this method are measured. Using airborne particulate matter and biomonitor chosen as environmental indicators, trace elemental concentrations of sample collected at urban and rural site monthly are determined ant then the calculation of statistics and the factor analysis are carried out for investigation of emission source. Facilities for NAA are installed in a new HANARO reactor, functional test is performed for routine operation. In addition, unified software code for NAA is developed to improve accuracy, precision and abilities of analytical processes. (author). 103 refs., 61 tabs., 19 figs

  18. An Optimized Method for Quantification of Pathogenic Leptospira in Environmental Water Samples.

    Science.gov (United States)

    Riediger, Irina N; Hoffmaster, Alex R; Casanovas-Massana, Arnau; Biondo, Alexander W; Ko, Albert I; Stoddard, Robyn A

    2016-01-01

    Leptospirosis is a zoonotic disease usually acquired by contact with water contaminated with urine of infected animals. However, few molecular methods have been used to monitor or quantify pathogenic Leptospira in environmental water samples. Here we optimized a DNA extraction method for the quantification of leptospires using a previously described Taqman-based qPCR method targeting lipL32, a gene unique to and highly conserved in pathogenic Leptospira. QIAamp DNA mini, MO BIO PowerWater DNA and PowerSoil DNA Isolation kits were evaluated to extract DNA from sewage, pond, river and ultrapure water samples spiked with leptospires. Performance of each kit varied with sample type. Sample processing methods were further evaluated and optimized using the PowerSoil DNA kit due to its performance on turbid water samples and reproducibility. Centrifugation speeds, water volumes and use of Escherichia coli as a carrier were compared to improve DNA recovery. All matrices showed a strong linearity in a range of concentrations from 106 to 10° leptospires/mL and lower limits of detection ranging from Leptospira in environmental waters (river, pond and sewage) which consists of the concentration of 40 mL samples by centrifugation at 15,000×g for 20 minutes at 4°C, followed by DNA extraction with the PowerSoil DNA Isolation kit. Although the method described herein needs to be validated in environmental studies, it potentially provides the opportunity for effective, timely and sensitive assessment of environmental leptospiral burden.

  19. Designing an enhanced groundwater sample collection system

    International Nuclear Information System (INIS)

    Schalla, R.

    1994-10-01

    As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at the Laboratory for Energy and Health-Related Research (LEHR), Pacific Northwest Laboratory (PNL) provided guidance on the design and construction of monitoring wells and identified the most suitable type of groundwater sampling pump and accessories for monitoring wells. The goal was to utilize a monitoring well design that would allow for hydrologic testing and reduce turbidity to minimize the impact of sampling. The sampling results of the newly designed monitoring wells were clearly superior to those of the previously installed monitoring wells. The new wells exhibited reduced turbidity, in addition to improved access for instrumentation and hydrologic testing. The variable frequency submersible pump was selected as the best choice for obtaining groundwater samples. The literature references are listed at the end of this report. Despite some initial difficulties, the actual performance of the variable frequency, submersible pump and its accessories was effective in reducing sampling time and labor costs, and its ease of use was preferred over the previously used bladder pumps. The surface seals system, called the Dedicator, proved to be useful accessory to prevent surface contamination while providing easy access for water-level measurements and for connecting the pump. Cost savings resulted from the use of the pre-production pumps (beta units) donated by the manufacturer for the demonstration. However, larger savings resulted from shortened field time due to the ease in using the submersible pumps and the surface seal access system. Proper deployment of the monitoring wells also resulted in cost savings and ensured representative samples

  20. Proton Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrometry (AAS) applied in the environmental sample analysis

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Iordan, M.; Stihi, C.; Bancuta, A.; Dima, G.; Busuioc, G.; Ciupina, V.; Belc, M.; Badica, T.

    2003-01-01

    The aim of this work is to determine the elemental composition of tree leaves using Proton-Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrophotometry (AAS) methods. By PIXE Spectrometry we identified and determined the concentration of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu Zn, As, Br, Sr and by AAS method the concentration of elements: Cr, Mn, Fe, Co, Cu, Zn, Se, Cd. Pb was identified in only 2 samples from 29. For tree leave samples collected at a large distance to the polluting source the Sr concentration decreased and the Mg, Ca, Se, Zn and Fe concentrations increased. Also, we can observe a small affinity of these leaves for the environmental Pb which was detected for two samples at a small distance to polluting source. (authors)

  1. ISCO Grab Sample Ion Chromatography Analytical Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — ISCO grab samples were collected from river, wastewater treatment plant discharge, and public drinking water intakes. Samples were analyzed for major ions (ppb)...

  2. Oak Ridge Reservation Annual Site Environmental Report, 2003

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, JF

    2004-08-24

    This document is prepared annually to summarize environmental activities, primarily environmental-monitoring activities, on the ORR and within the ORR surroundings. The document fulfills the requirement of U.S. Department of Energy (DOE) Order 231.1, ''Environment, Safety and Health Reporting,'' for an annual summary of environmental data to characterize environmental performance. The environmental monitoring criteria are described in DOE Order 450.1, ''Environmental Protection Program''. The results summarized in this report are based on data collected prior to and through 2003. This report is not intended to provide the results of all sampling on the ORR. Additional data collected for other site and regulatory purposes, such as environmental restoration remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws. Corrections to the report for the previous year are found in Appendix A. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the point of release to the environment; these measurements allow the quantification and official reporting of contaminants, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of the collection and analysis of environmental samples from the site and its environs; these activities provide direct measurement of contaminants in air, water, groundwater, soil, foods, biota, and other media subsequent to effluent release into the environment. Environmental surveillance data provide information regarding

  3. Quality-control design for surface-water sampling in the National Water-Quality Network

    Science.gov (United States)

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  4. Method validation and uncertainty evaluation of organically bound tritium analysis in environmental sample.

    Science.gov (United States)

    Huang, Yan-Jun; Zeng, Fan; Zhang, Bing; Chen, Chao-Feng; Qin, Hong-Juan; Wu, Lian-Sheng; Guo, Gui-Yin; Yang, Li-Tao; Shang-Guan, Zhi-Hong

    2014-08-01

    The analytical method for organically bound tritium (OBT) was developed in our laboratory. The optimized operating conditions and parameters were established for sample drying, special combustion, distillation, and measurement on a liquid scintillation spectrometer (LSC). Selected types of OBT samples such as rice, corn, rapeseed, fresh lettuce and pork were analyzed for method validation of recovery rate reproducibility, the minimum detection concentration, and the uncertainty for typical low level environmental sample was evaluated. The combustion water recovery rate of different dried environmental sample was kept at about 80%, the minimum detection concentration of OBT ranged from 0.61 to 0.89 Bq/kg (dry weight), depending on the hydrogen content. It showed that this method is suitable for OBT analysis of environmental sample with stable recovery rate, and the combustion water yield of a sample with weight about 40 g would provide sufficient quantity for measurement on LSC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Pursuit of improvement in uranium bulk analysis at the clear facility for safeguards environmental samples

    International Nuclear Information System (INIS)

    Sakurai, S.; Takahashi, M.; Sakakibara, T.; Magara, M.; Kurosawa, S.; Esaka, F.; Takai, K.; Watanabe, K.; Usuda, S.; Adachi, T.

    2002-01-01

    Full text: In order to contribute to the IAEA strengthened safeguards system, a project started in Japan Atomic Energy Research Institute (JAERI) in 1998. Consequently, a clean room facility called as CLEAR, the Clean Laboratory for Environmental Analysis and Research, was constructed in June 2001 at JAERI Tokai and the analytical techniques of ultra-trace nuclear materials in environmental samples are being developed. As for the bulk analysis, performance of inductively-coupled plasma mass spectrometry (ICP-MS) was mainly examined because sample preparation for ICP-MS is simpler than that for thermal ionization mass spectrometry (TIMS). Interference of polyatomic ion (such as PtAr + ) and coexisting element (such as Na) on the uranium ions, as well as mass bias caused by ICP-MS operating conditions, has been investigated for precise measurement on uranium isotope ratio. The authors have also studied on the uranium blanks during sample treatment process. The blank value below 10 pg uranium per sample treatment was obtained: dominant origins were elution from Teflon vessel surface in acid heating process of the sample to dry up. The work is in progress to minimize the blank. Compared with the process blank and the minimum uranium amount for isotope ratio measurement by ICP-MS (ca. 10 pg for natural uranium), the swipe cotton (Texwipe-304) which is currently used for IAEA Environmental Sampling includes much more amount of natural uranium in several nano-grams. If the amount of uranium collected on Texwipe-304 is small, sensitive and reliable measurement on isotope ratio will be impossible by bulk analysis. The authors are seeking alternative swipe materials with less amount of uranium. Recently, one of the authors devised an effective technique for recovery of uranium-containing particles from Texwipe-304. The technique, named as Vacuum Suction Method, uses a combination of polycarbonate membrane filters and a macro-pipette tip, which is connected to a vacuum pump

  6. An overview of sample preparation procedures for LC-MS multiclass antibiotic determination in environmental and food samples.

    Science.gov (United States)

    Moreno-Bondi, María Cruz; Marazuela, María Dolores; Herranz, Sonia; Rodriguez, Erika

    2009-10-01

    Antibiotics are a class of pharmaceuticals that are of great interest due to the large volumes of these substances that are consumed in both human and veterinary medicine, and due to their status as the agents responsible for bacterial resistance. They can be present in foodstuffs and in environmental samples as multicomponent chemical mixtures that exhibit a wide range of mechanisms of action. Moreover, they can be transformed into different metabolites by the action of microorganisms, as well as by other physical or chemical means, resulting in mixtures with higher ecotoxicities and risks to human health than those of the individual compounds. Therefore, there is growing interest in the availability of multiclass methods for the analysis of antimicrobial mixtures in environmental and food samples at very low concentrations. Liquid chromatography (LC) has become the technique of choice for multiclass analysis, especially when coupled to mass spectrometry (LC-MS) and tandem MS (LC-MS(2)). However, due to the complexity of the matrix, in most cases an extraction step for sample clean-up and preconcentration is required before analysis in order to achieve the required sensitivities. This paper reviews the most recent developments and applications of multiclass antimicrobial determination in environmental and food matrices, emphasizing the practical aspects of sample preparation for the simultaneous extraction of antimicrobials from the selected samples. Future trends in the application of LC-MS-based techniques to multiclass antibiotic analysis are also presented.

  7. Nuclear techniques for analysis of environmental samples

    International Nuclear Information System (INIS)

    1986-12-01

    The main purposes of this meeting were to establish the state-of-the-art in the field, to identify new research and development that is required to provide an adequate framework for analysis of environmental samples and to assess needs and possibilities for international cooperation in problem areas. This technical report was prepared on the subject based on the contributions made by the participants. A separate abstract was prepared for each of the 9 papers

  8. Promoting Pro-Environmental Behaviour: Collection of Used Batteries by Secondary School Pupils

    Science.gov (United States)

    Rioux, Liliane

    2011-01-01

    This research is based on Kollmuss and Agyeman's mode, and aims to determine if the prerequisites for pro-environmental behaviour, such as the collection of used batteries at school, are ethical, cognitive and environmental. A questionnaire/opinionnaire was given to 102, 14-17-year-olds to gather data on: (1) their current recycling habits, (2)…

  9. Surface water sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    This Sampling and Analysis Plan addresses surface water monitoring, sampling, and analysis activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Surface water monitoring will be conducted at nine sites within WAG 6. Activities to be conducted will include the installation, inspection, and maintenance of automatic flow-monitoring and sampling equipment and manual collection of various water and sediment samples. The samples will be analyzed for various organic, inorganic, and radiological parameters. The information derived from the surface water monitoring, sampling, and analysis will aid in evaluating risk associated with contaminants migrating off-WAG, and will be used in calculations to establish relationships between contaminant concentration (C) and flow (Q). The C-Q relationship will be used in calculating the cumulative risk associated with the off-WAG migration of contaminants.

  10. Surface water sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    International Nuclear Information System (INIS)

    1994-06-01

    This Sampling and Analysis Plan addresses surface water monitoring, sampling, and analysis activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Surface water monitoring will be conducted at nine sites within WAG 6. Activities to be conducted will include the installation, inspection, and maintenance of automatic flow-monitoring and sampling equipment and manual collection of various water and sediment samples. The samples will be analyzed for various organic, inorganic, and radiological parameters. The information derived from the surface water monitoring, sampling, and analysis will aid in evaluating risk associated with contaminants migrating off-WAG, and will be used in calculations to establish relationships between contaminant concentration (C) and flow (Q). The C-Q relationship will be used in calculating the cumulative risk associated with the off-WAG migration of contaminants

  11. Systematic review and consensus guidelines for environmental sampling of Burkholderia pseudomallei.

    Directory of Open Access Journals (Sweden)

    Direk Limmathurotsakul

    Full Text Available Burkholderia pseudomallei, a Tier 1 Select Agent and the cause of melioidosis, is a Gram-negative bacillus present in the environment in many tropical countries. Defining the global pattern of B. pseudomallei distribution underpins efforts to prevent infection, and is dependent upon robust environmental sampling methodology. Our objective was to review the literature on the detection of environmental B. pseudomallei, update the risk map for melioidosis, and propose international consensus guidelines for soil sampling.An international working party (Detection of Environmental Burkholderia pseudomallei Working Party (DEBWorP was formed during the VIth World Melioidosis Congress in 2010. PubMed (January 1912 to December 2011 was searched using the following MeSH terms: pseudomallei or melioidosis. Bibliographies were hand-searched for secondary references. The reported geographical distribution of B. pseudomallei in the environment was mapped and categorized as definite, probable, or possible. The methodology used for detecting environmental B. pseudomallei was extracted and collated. We found that global coverage was patchy, with a lack of studies in many areas where melioidosis is suspected to occur. The sampling strategies and bacterial identification methods used were highly variable, and not all were robust. We developed consensus guidelines with the goals of reducing the probability of false-negative results, and the provision of affordable and 'low-tech' methodology that is applicable in both developed and developing countries.The proposed consensus guidelines provide the basis for the development of an accurate and comprehensive global map of environmental B. pseudomallei.

  12. IMPROVEMENT OF METHODS FOR HYDROBIOLOGICAL RESEARCH AND MODIFICATION OF STANDARD TOOLS FOR SAMPLE COLLECTION

    Directory of Open Access Journals (Sweden)

    M. M. Aligadjiev

    2015-01-01

    Full Text Available Aim. The paper discusses the improvement of methods of hydrobiological studies by modifying tools for plankton and benthic samples collecting. Methods. In order to improve the standard methods of hydro-biological research, we have developed tools for sampling zooplankton and benthic environment of the Caspian Sea. Results. Long-term practice of selecting hydrobiological samples in the Caspian Sea shows that it is required to complete the modernization of the sampling tools used to collect hydrobiological material. With the introduction of Azov and Black Sea invasive comb jelly named Mnemiopsis leidyi A. Agassiz to the Caspian Sea there is a need to collect plankton samples without disturbing its integrity. Tools for collecting benthic fauna do not always give a complete picture of the state of benthic ecosystems because of the lack of visual site selection for sampling. Moreover, while sampling by dredge there is a probable loss of the samples, especially in areas with difficult terrain. Conclusion. We propose to modify a small model of Upstein net (applied in shallow water to collect zooplankton samples with an upper inverted cone that will significantly improve the catchability of the net in theCaspian Sea. Bottom sampler can be improved by installing a video camera for visual inspection of the bottom topography, and use sensors to determine tilt of the dredge and the position of the valves of the bucket. 

  13. A semi-empirical approach to calculate gamma activities in environmental samples

    International Nuclear Information System (INIS)

    Palacios, D.; Barros, H.; Alfonso, J.; Perez, K.; Trujillo, M.; Losada, M.

    2006-01-01

    We propose a semi-empirical method to calculate radionuclide concentrations in environmental samples without the use of reference material and avoiding the typical complexity of Monte-Carlo codes. The calculation of total efficiencies was carried out from a relative efficiency curve (obtained from the gamma spectra data), and the geometric (simulated by Monte-Carlo), absorption, sample and intrinsic efficiencies at energies between 130 and 3000 keV. The absorption and sample efficiencies were determined from the mass absorption coefficients, obtained by the web program XCOM. Deviations between computed results and measured efficiencies for the RGTh-1 reference material are mostly within 10%. Radionuclide activities in marine sediment samples calculated by the proposed method and by the experimental relative method were in satisfactory agreement. The developed method can be used for routine environmental monitoring when efficiency uncertainties of 10% can be sufficient.(Author)

  14. Organising Collective Action for Effective Environmental Management and Social Learning in Wales

    Science.gov (United States)

    Mills, Jane; Gibbon, David; Ingram, Julie; Reed, Matt; Short, Christopher; Dwyer, Janet

    2011-01-01

    The paper explored key factors that might lead to successful agri-environmental social learning and collective action in order to deliver landscape-scale resource management within agri-environment schemes. Using the theory of collective action as an analytical framework the paper examined findings from in-depth interviews with 20 members of two…

  15. Determination of Sr-90 in environmental samples using solid phase extraction disk

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood

    2002-01-01

    A method is described for determination of Sr-90 in environmental samples using solid phase extraction disk (Empore TM Strontium Rad Disk) and GM counter. To determine the optimum condition for capacity of Empore TM Strontium Rad Disk, its characterization studies such as the effects Sr content, acidity (molarity) of acids, presence of Ca 2+ and other major ions (Na + , Mg 2+ etc), influence of interference (Pb and Bi) and others were carried out. An optimized the using of Empore TM Strontium Rad Disk for determination of Sr-90 was validated by application to environmental samples. Quantitative recoveries above 95%for Sr (stable) were recorded in 6M HCl condition. Typical environmental samples may contain an assortment of anionic and cationic species, but in general, Empore TM Strontium Rad Disk has enough capacity to effectively separate Sr for wide variety of aqueous solutions. Sr recovery in a matrix-free or the content of matrix less than 300 mg/sample is typically greater than 99% is reported in this research work. In particular, sample, which may contain interference such as Pb and Bi would require an addition separation step before processing to ensure an accurate measurement of Sr. In this research work, radiotracer 85 Sr was used to monitor the behavior of Sr and calculation its recovery. For analytical methods that can count Y-90, the Sr-90 activity/concentration in environmental sample was calculated. The concentration of Sr-90 in ash sample (Quality Controled Sample) of 276 ± 18 Bq/kg ash was determined from Y-90 activity. The relative percent difference of 1.1% was achievable for Empore TM Sr-Rad Disk methods when compared to the conventional method (fumed-HNO 3 method) - 279 ± 11 Bq/kg ash. (Author)

  16. Spectrophotometric Determination of Boron in Environmental Water Samples

    International Nuclear Information System (INIS)

    San San; Khin Win Kyi; Kwaw Naing

    2002-02-01

    The present paper deals with the study on the methods for the determination of boron in the environmental water samples. The standard methods which are useful for this determination are discussed thoroughly in this work. Among the standard methods approved by American Public Health Association, the carmine method was selected for this study. Prior to the determination of boron in the water samples, the precision and accuracy of the methods of choice were examined by using standard boron solutions. The determination of Boron was carried out by using water samples, waste water from Aquaculture Research Centre, University of Yangon, the Ayeyarwady River water near Magway Myathalon Pagoda in Magway Division, ground water from Sanchaung Township, and tap water from Universities' Research Centre, University of Yangon. Analyses of these water samples were done and statistical treatment of the results was carried out. (author)

  17. Multi-edge X-ray absorption spectroscopy study of road dust samples from a traffic area of Venice using stoichiometric and environmental references

    Science.gov (United States)

    Valotto, Gabrio; Cattaruzza, Elti; Bardelli, Fabrizio

    2017-02-01

    The appropriate selection of representative pure compounds to be used as reference is a crucial step for successful analysis of X-ray absorption near edge spectroscopy (XANES) data, and it is often not a trivial task. This is particularly true when complex environmental matrices are investigated, being their elemental speciation a priori unknown. In this paper, an investigation on the speciation of Cu, Zn, and Sb based on the use of conventional (stoichiometric compounds) and non-conventional (environmental samples or relevant certified materials) references is explored. This method can be useful in when the effectiveness of XANES analysis is limited because of the difficulty in obtaining a set of references sufficiently representative of the investigated samples. Road dust samples collected along the bridge connecting Venice to the mainland were used to show the potentialities and the limits of this approach.

  18. Occurrence of Thermotolerant Campylobacter in Raw Poultry Meat, Environmental and Pigeon Stools Collected in Open-Air Markets.

    Science.gov (United States)

    Bellio, Alberto; Traversa, Amaranta; Adriano, Daniela; Bianchi, Daniela Manila; Colzani, Alberto; Gili, Stefano; Dondo, Alessandro; Gallina, Silvia; Grattarola, Carla; Maurella, Cristiana; Zoppi, Simona; Zuccon, Fabio; Decastelli, Lucia

    2014-08-28

    Campylobacteriosis was the most commonly reported zoonosis for confirmed human cases in European Union during 2011. Poultry meat was very often implicated in Campylobacter infections in humans. In Italy commerce of raw poultry meat is common in open-air markets: these areas can be considered at high risk of bacterial contamination due to the high presence birds like pigeons. The aim of this study was to collect data about the contamination by thermotolerant Campylobacter of raw poultry meat commercialised in open-air markets, of work-surfaces in contact with poultry meat and of pigeon stools sampled in the market areas in Turin, Northern Italy. Between September 2011 and December 2012, 86 raw poultry meat samples, 86 environmental swabs and 108 animal samples were collected in 38 open-air markets. Analysis were carried out according to ISO10272-1:2006 standard. C.coli was detected in 2.3% (2/86) of raw poultry meat samples, whereas no swab (0/86) resulted positive. Of pigeon stool 28% (30/107) was positive for C.jejuni (83.3% C.jejuni subsp . jejuni and 16.7% C.jejuni subsp . doylei ). C.jejuni subsp. jejuni was isolated from 1 dead pigeon . Our results showed lower rates of contamination than those reported at retail in Europe. Although samples were collected in areas at high risk of contamination, raw poultry meat and work surfaces reported a low level of presence of thermotolerant Campylobacter . The high percentage of C.jejuni isolated from pigeon stools showed the importance of a continuous application of preventive measures by the food business operators and the surveillance activity by the Competent Authority.

  19. Rapid PCR using nested primers of the 16S rRNA and the hippuricase (hipO) genes to detect Campylobacter jejuni and Campylobacter coli in environmental samples

    DEFF Research Database (Denmark)

    Bang, Dang Duong; Wedderkopp, A.; Pedersen, Karl

    2002-01-01

    sensitivity due to the use of selective media, the low number of bacteria in the samples and possibly also due to the presence of non-culturable or sub-lethally injured stages of the bacteria. The present paper describes a rapid PCR assay using nested primers of the 16S rRNA or the hippuricase (hipO) genes...... to detect Campylobacter jejuni and Campylobacter coli in environmental samples. The sensitivity of the nested PCR was determined to be 0.01 pg/PCR, corresponding to 2-3 colony forming units (cfu) per ml. The nested PCR assays were applied to detect C. jejuni and C. coli in 269 environmental samples...... collected from ten broiler farms. The sensitivity, specificity and the usefulness of the PCR assay for detection of C. jejuni and C coli in environmental samples are presented and discussed....

  20. Environmental surveillance at Hanford for CY-1975 data

    International Nuclear Information System (INIS)

    Blumer, P.J.; Fix, J.J.; Speer, D.R.

    1976-04-01

    This document contains detailed data collected by the Hanford Environmental Surveillance program during 1975. Environmental Surveillance responsibilities at Hanford are divided between Hanford Environmental Health Foundation (HEHF) and Battelle-Northwest (BNW). HEHF is responsible for measuring all nonradiological air quality and sanitary water parameters of interest. BNW is responsible for measuring radiological parameters in all environmental media of significance and for measuring both radiological and nonradiological parameters of Columbia River water and ground water. A brief description of the method and location of sample collection during 1975 is included. Data are tabulated on the content of specific radionuclides in surface air. Columbia River water, drinking water, ground water, foods, fish, and wild animals. Data are also included on content of NO 2 and SO 2 in air, nitrates in Columbia River water, ground water, and drinking water, and water quality of samples of Columbia River water collected at various sampling locations

  1. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  2. Human blood RNA stabilization in samples collected and transported for a large biobank

    Science.gov (United States)

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  3. Collection and preparation of water samples for hydrogeochemical reconnaissance

    International Nuclear Information System (INIS)

    Baucom, E.I.; Ferguson, R.B.; Wallace, R.M.

    1977-01-01

    A method based on ion exchange and neutron activation analysis (NAA) was developed and field-tested to determine uranium over the range 0.02 to 10,000 ppb in natural water using a single procedure. Water samples are filtered in the field using a specially-designed one-liter filter apparatus pressurized to 40 psig with an inert gas. The filtered water is treated with a high purity, mixed cation-anion resin in the hydronium-hydroxide form. All ions are removed from solution under the strong driving force of the neutralization reaction. Anionic, cationic, and natural complexes of uranium can be concentrated with this method. Field tests showed greater than 95 percent recovery of 13 elements analyzed (including greater than 99 percent recovery of uranium) and greater than or equal to 90 percent recovery of 4 other elements. Uranium collected on the resin was quantitatively determined by NAA. Coefficient of variation for sampling plus analysis was less than 20 percent for samples containing more than 0.1 ppb uranium. Advantages of this method include: (1) wide dynamic range, (2) low detection limit for uranium (0.02 ppb), (3) high precision and accuracy, (4) relatively low cost, (5) high-yield recovery from low-level aqueous samples without risk of loss to containers, (6) decreased risk of significant sample contamination compared with other low-level methods, (7) production of stable samples suitable for retrievable storage, and(8) concentration of other ions that can be determined by NAA. This paper presents (1) background regarding development of procedures for sample collection and preparation, (2) results of development programs, (3) description of equipment and field procedures, and (4) preliminary conclusions regarding use of this technology for hydrogeochemical reconnaissance for uranium

  4. Applicability of non-invasively collected matrices for human biomonitoring

    Directory of Open Access Journals (Sweden)

    Nickmilder Marc

    2009-03-01

    Full Text Available Abstract With its inclusion under Action 3 in the Environment and Health Action Plan 2004–2010 of the European Commission, human biomonitoring is currently receiving an increasing amount of attention from the scientific community as a tool to better quantify human exposure to, and health effects of, environmental stressors. Despite the policy support, however, there are still several issues that restrict the routine application of human biomonitoring data in environmental health impact assessment. One of the main issues is the obvious need to routinely collect human samples for large-scale surveys. Particularly the collection of invasive samples from susceptible populations may suffer from ethical and practical limitations. Children, pregnant women, elderly, or chronically-ill people are among those that would benefit the most from non-invasive, repeated or routine sampling. Therefore, the use of non-invasively collected matrices for human biomonitoring should be promoted as an ethically appropriate, cost-efficient and toxicologically relevant alternative for many biomarkers that are currently determined in invasively collected matrices. This review illustrates that several non-invasively collected matrices are widely used that can be an valuable addition to, or alternative for, invasively collected matrices such as peripheral blood sampling. Moreover, a well-informed choice of matrix can provide an added value for human biomonitoring, as different non-invasively collected matrices can offer opportunities to study additional aspects of exposure to and effects from environmental contaminants, such as repeated sampling, historical overview of exposure, mother-child transfer of substances, or monitoring of substances with short biological half-lives.

  5. Development of environmental sample analysis techniques for safeguards

    International Nuclear Information System (INIS)

    Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka

    1999-01-01

    JAERI has been developing environmental sample analysis techniques for safeguards and preparing a clean chemistry laboratory with clean rooms. Methods to be developed are a bulk analysis and a particle analysis. In the bulk analysis, Inductively-Coupled Plasma Mass Spectrometer or Thermal Ionization Mass Spectrometer are used to measure nuclear materials after chemical treatment of sample. In the particle analysis, Electron Probe Micro Analyzer and Secondary Ion Mass Spectrometer are used for elemental analysis and isotopic analysis, respectively. The design of the clean chemistry laboratory has been carried out and construction will be completed by the end of March, 2001. (author)

  6. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    Science.gov (United States)

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  7. Optimizing detection of noble gas emission at a former UNE site: sample strategy, collection, and analysis

    Science.gov (United States)

    Kirkham, R.; Olsen, K.; Hayes, J. C.; Emer, D. F.

    2013-12-01

    Underground nuclear tests may be first detected by seismic or air samplers operated by the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization). After initial detection of a suspicious event, member nations may call for an On-Site Inspection (OSI) that in part, will sample for localized releases of radioactive noble gases and particles. Although much of the commercially available equipment and methods used for surface and subsurface environmental sampling of gases can be used for an OSI scenario, on-site sampling conditions, required sampling volumes and establishment of background concentrations of noble gases require development of specialized methodologies. To facilitate development of sampling equipment and methodologies that address OSI sampling volume and detection objectives, and to collect information required for model development, a field test site was created at a former underground nuclear explosion site located in welded volcanic tuff. A mixture of SF-6, Xe127 and Ar37 was metered into 4400 m3 of air as it was injected into the top region of the UNE cavity. These tracers were expected to move towards the surface primarily in response to barometric pumping or through delayed cavity pressurization (accelerated transport to minimize source decay time). Sampling approaches compared during the field exercise included sampling at the soil surface, inside surface fractures, and at soil vapor extraction points at depths down to 2 m. Effectiveness of various sampling approaches and the results of tracer gas measurements will be presented.

  8. Oak Ridge Reservation Annual Site Environmental Report for 2003

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-09-30

    This document is prepared annually to summarize environmental activities, primarily environmental-monitoring activities, on the ORR and within the ORR surroundings. The document fulfills the requirement of U.S. Department of Energy (DOE) Order 231.1, “Environment, Safety and Health Reporting,” for an annual summary of environmental data to characterize environmental performance. The environmental monitoring criteria are described in DOE Order 450.1, “Environmental Protection Program.” The results summarized in this report are based on data collected prior to and through 2003. This report is not intended to provide the results of all sampling on the ORR. Additional data collected for other site and regulatory purposes, such as environmental restoration remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws. Corrections to the report for the previous year are found in Appendix A. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the point of release to the environment; these measurements allow the quantification and official reporting of contaminants, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of the collection and analysis of environmental samples from the site and its environs; these activities provide direct measurement of contaminants in air, water, groundwater, soil, foods, biota, and other media subsequent to effluent release into the environment. Environmental surveillance data provide information regarding conformity with applicable DOE

  9. Oak Ridge Reservation Annual Site Environmental Report for 2006

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, Wayne [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Y-12 Complex; Hughes, Joan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Coffey, Mike [East Tennessee Technology Park (ETTP), Oak Ridge, TN (United States); Thompson, Sharon [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2007-09-01

    This document is prepared annually to summarize environmental activities, primarily environmental-monitoring activities, on the Oak Ridge Reservation (ORR) and within the ORR surroundings. The document fulfills the requirement of Department of Energy (DOE) Order 23l.IA, 'Environment, Safety and Health Reporting,' for an annual summary of environmental data to characterize environmental performance. The environmental-monitoring criteria are described in DOE Order 450.1, 'Environmental Protection Program.' The results summarized in this report are based on data collected prior to and through 2006. This report is not intended to provide the results of all sampling on the ORR. Additional data collected for other site and regulatory purposes, such as environmental restoration remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws and are referenced herein as appropriate. Corrections to the report for the previous year are found in Appendix A. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the point of release to the environment; these measurements allow the quantification and official reporting of contaminants, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of the collection and analysis of environmental samples from the site and its environs; these activities provide direct measurement of contaminant concentrations in air, water, groundwater, soil, foods, biota, and other media. Environmental surveillance data provide information regarding

  10. The Idaho National Engineering Laboratory site environmental report for calendar year 1989

    International Nuclear Information System (INIS)

    Hoff, D.L.; Mitchell, R.G.; Bowman, G.C.; Moore, R.

    1990-06-01

    To verify that exposures resulting from operations at the Department of Energy (DOE) nuclear facilities have remained very small, each site at which nuclear activities are underway operates an environmental surveillance program to monitor the air, water and any other pathway where radionuclides from operations might conceivably reach workers or members of the public. This report presents data collected in 1989 for the routine environmental surveillance program conducted by the Radiological and Environmental Sciences Laboratory (RESL) of DOE and the US Geological Survey (USGS) at the Idaho National Engineering Laboratory (INEL) site. The environmental surveillance program for the INEL and vicinity for 1989 included the collection and analysis of samples from potential exposure pathways. Three basic groups of samples were collected. Those collected within the INEL boundaries will be referred to as onsite samples. Samples collected outside, but near, the Site boundaries will be referred to as boundary samples or part of a group of offsite samples. Samples collected from locations considerably beyond the Site boundaries will be referred to as distant samples or part of the offsite group. With the exception of Craters of the Moon National Monument, the distant locations are sufficiently remote from the Site to ensure that detectable radioactivity is primarily due to natural background sources or sources other than INEL operations. 35 refs., 14 figs., 13 tabs

  11. Study of Efficiency Calibrations of HPGe Detectors for Radioactivity Measurements of Environmental Samples

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.

    2009-01-01

    In this paper, we describe a method of calibrating of efficiency of a HPGe gamma-ray spectrometry of bulk environmental samples (Tea, crops, water, and soil) is a significant part of the environmental radioactivity measurements. Here we will discuss the full energy peak efficiency (FEPE) of three HPGe detectors it as a consequence, it is essential that the efficiency is determined for each set-up employed. Besides to take full advantage at gamma-ray spectrometry, a set of efficiency at several energies which covers the wide the range in energy, the large the number of radionuclides whose concentration can be determined to measure the main natural gamma-ray emitters, the efficiency should be known at least from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y). Radioactive sources were prepared from two different standards, a first mixed standard QC Y 40 containing 210 Pb, 241 Am, 109 Cd, and Co 57 , and the second QC Y 48 containing 241 Am, 109 Cd, 57 Co, 139 Ce, 113 Sn, 85 Sr, 137 Cs, 88 Y, and 60 Co is necessary in order to calculate the activity of the different radionuclides contained in a sample. In this work, we will study the efficiency calibration as a function of different parameters as:- Energy of gamma ray from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y), three different detectors A, B, and C, geometry of containers (point source, marinelli beaker, and cylindrical bottle 1 L), height of standard soil samples in bottle 250 ml, and density of standard environmental samples. These standard environmental sample must be measured before added standard solution because we will use the same environmental samples in order to consider the self absorption especially and composition in the case of volume samples.

  12. Long-term survival of Cryptococcus neoformans and Cryptococcus gattii in stored environmental samples from Colombia.

    Science.gov (United States)

    Escandón, Patricia; Castañeda, Elizabeth

    2015-01-01

    Both Cryptococcus neoformans and Cryptococcus gattii have been isolated from a variety of environmental sources in Colombia. To determine the viability of C. neoformans/C. gattii isolates in stored soil samples, filtrates and bird droppings from which these yeasts were previously recovered. A total of 964 samples collected between 2003 and 2009, and kept at room temperature were processed. From them, 653 samples were from trees decaying wood, 274 from soil filtrates and 37 from bird droppings. When C. neoformans or C. gattii were recovered, the molecular type of each isolate was established by PCR fingerprinting using the single primer (GTG)5. Among the processed samples, 161 isolates were recovered. From those, 81 (50.3%) corresponded to C. gattii recovered from decaying wood of Eucalyptus spp., Corymbia ficifolia, Terminalia catappa and Ficus spp. trees, and 80 (49.7%) corresponded to C. neoformans recovered from Ficus spp. and eucalyptus trees, as well as from bird droppings. The most prevalent molecular type among the C. gattii and C. neoformans isolates was VGII and VNI, respectively. The re-isolation of C. neoformans/C. gattii from 10-year stored samples suggests that these yeasts are able to keep viable in naturally colonized samples. Copyright © 2013 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.

  13. Enhanced bacterial affinity of PVDF membrane: its application as improved sea water sampling tool for environmental monitoring.

    Science.gov (United States)

    Kumar, Sweta Binod; Sharnagat, Preeti; Manna, Paramita; Bhattacharya, Amit; Haldar, Soumya

    2017-02-01

    Isolation of diversified bacteria from seawater is a major challenge in the field of environmental microbiology. In the present study, an attempt has been made to select specific membrane with improved property of attaching diversified bacteria. Initially, different concentrations (15, 18, and 20% W/W) of polysulfone (PSF) were used to check their affinity for the attachment of selected gram-positive (Bacillus subtilis) and gram-negative (Escherichia coli) bacteria. Among these, 20% W/W PSF showed maximum attachment. Therefore, membrane prepared with other materials such as polyvinylidene fluoride (PVDF) and polyether sulfone (PES) were used with the same concentration (20% W/W) to check their improved bacterial attachment property. Comparative study of bacterial attachment on three different membranes revealed that PVDF possessed the highest affinity towards both the groups of bacteria. This property was confirmed by different analytical methods viz. contact angle, atomic force microscopy, zeta potential, and flux study and further validated with seawater samples collected from seven sites of western coast and Lakshadweep island of India, using Biolog EcoPlate™. All the samples showed that bacterial richness and diversity was high in PVDF membrane in comparison to surrounding seawater samples. Interestingly, affinity for more diversified bacteria was reported to be higher in water sample with less turbidity and low bacteria load. This finding can facilitate the development of PVDF (20% W/W) membrane as a simple, cheap, and less labor intensive environmental sampling tool for the isolation of diversified bacteria from seawater sample wih different physiochemical properties. Graphical abstract ᅟ.

  14. Determination of Cs-134 and Cs-137 in different food-stuffs and environmental-stuffs collected from Serina area in Lombardy

    International Nuclear Information System (INIS)

    Rimoldi, E.M.; Di Giancamillo, M.; Cavallone, E.; Brambilla, P.

    1999-01-01

    After the explosion of the reactor n°4 in the Ukrainian Nuclear Power Plant of Chernobyl, the highest radioactive contamination in Italy was observed in Lumbardy. In 1996, ten years after the Chernobyl's accident, the Authors carried out an investigation on soil samples from Serina area, in the district of Bergamo. N°158 samples have been analysed by NaI(Tl) detector (3x3), collected from surface soil and subsoil, running and stagnating waters, mosses, lichens, mushrooms, water-plants, fodder leafage, berries, pine-needles, striated muscle from cattle, sheep, chamois, roe-deer, milk and cheeses from cow and goat, chicken eggs. In all the soil samples analysed Cs-137 was detectable, and its activity was constantly higher in surface soil samples and particularly in those from woods. In May, the seasonal fallout period at our latitudes, it has been detected on Alben Mount a light fallout of Cs-134. In the samples collected on poly-phyto meadows no trace of Cs-137 has been detected, while in samples from wood's ecosystem this isotope was always detectable. Cs-137 was also present in the muds of the bottom of a small natural alpine lake and in water-plants there growing. On the basis of these data the Authors infer that mosses and lichens are the best markers of environmental contamination due to Cs-137. They suggest that it is absolutely necessary to continue to control regularly every substrate included in the food chain and of zootechnic and environmental interest with the following aims: i) to study the capacity of various ecosystems to metabolize the products derived from the Chernobyl's accident; ii) to safeguard the public health against future emergencies: iii) to keep under control foodstuff for human and animal feeding, which, because of the markets' globalization, can arrive from everywhere

  15. Demonstration and determination of submicroscopic particles of uranium in environmental samples

    International Nuclear Information System (INIS)

    Sihelska, K.; Lorincik, J.; Sus, F.; Vesela, D.

    2016-01-01

    In this work laboratories of the Centrum vyzkumu Rez, Ltd are presented. Fission track analysis (FTA) is used for analysis of uranium in environmental samples. Treatment of samples for FTA is described and some results ar presented. The method of SIMS is used, too.

  16. Effects of holding time and measurement error on culturing Legionella in environmental water samples.

    Science.gov (United States)

    Flanders, W Dana; Kirkland, Kimberly H; Shelton, Brian G

    2014-10-01

    Outbreaks of Legionnaires' disease require environmental testing of water samples from potentially implicated building water systems to identify the source of exposure. A previous study reports a large impact on Legionella sample results due to shipping and delays in sample processing. Specifically, this same study, without accounting for measurement error, reports more than half of shipped samples tested had Legionella levels that arbitrarily changed up or down by one or more logs, and the authors attribute this result to shipping time. Accordingly, we conducted a study to determine the effects of sample holding/shipping time on Legionella sample results while taking into account measurement error, which has previously not been addressed. We analyzed 159 samples, each split into 16 aliquots, of which one-half (8) were processed promptly after collection. The remaining half (8) were processed the following day to assess impact of holding/shipping time. A total of 2544 samples were analyzed including replicates. After accounting for inherent measurement error, we found that the effect of holding time on observed Legionella counts was small and should have no practical impact on interpretation of results. Holding samples increased the root mean squared error by only about 3-8%. Notably, for only one of 159 samples, did the average of the 8 replicate counts change by 1 log. Thus, our findings do not support the hypothesis of frequent, significant (≥= 1 log10 unit) Legionella colony count changes due to holding. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. The Autism Simplex Collection : an international, expertly phenotyped autism sample for genetic and phenotypic analyses

    OpenAIRE

    Buxbaum, Joseph D.; Bolshakova, Nadia; Brownfeld, Jessica M.; Anney, Richard J. L.; Bender, Patrick; Bernier, Raphael; Cook, Edwin H.; Coon, Hilary; Cuccaro, Michael L.; Freitag, Christine M.; Hallmayer, Joachim; Geschwind, Daniel H.; Klauck, Sabine M.; Nurnberger, John I.; Oliveira, Guiomar

    2014-01-01

    Background: There is an urgent need for expanding and enhancing autism spectrum disorder (ASD) samples, in order to better understand causes of ASD. Methods: In a unique public-private partnership, 13 sites with extensive experience in both the assessment and diagnosis of ASD embarked on an ambitious, 2-year program to collect samples for genetic and phenotypic research and begin analyses on these samples. The program was called The Autism Simplex Collection (TASC). TASC sample collection ...

  18. State of the art of environmentally friendly sample preparation approaches for determination of PBDEs and metabolites in environmental and biological samples: A critical review.

    Science.gov (United States)

    Berton, Paula; Lana, Nerina B; Ríos, Juan M; García-Reyes, Juan F; Altamirano, Jorgelina C

    2016-01-28

    Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003-2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Isotope Enrichment Detection by Laser Ablation - Laser Absorption Spectrometry: Automated Environmental Sampling and Laser-Based Analysis for HEU Detection

    International Nuclear Information System (INIS)

    Anheier, Norman C.; Bushaw, Bruce A.

    2010-01-01

    The global expansion of nuclear power, and consequently the uranium enrichment industry, requires the development of new safeguards technology to mitigate proliferation risks. Current enrichment monitoring instruments exist that provide only yes/no detection of highly enriched uranium (HEU) production. More accurate accountancy measurements are typically restricted to gamma-ray and weight measurements taken in cylinder storage yards. Analysis of environmental and cylinder content samples have much higher effectiveness, but this approach requires onsite sampling, shipping, and time-consuming laboratory analysis and reporting. Given that large modern gaseous centrifuge enrichment plants (GCEPs) can quickly produce a significant quantity (SQ ) of HEU, these limitations in verification suggest the need for more timely detection of potential facility misuse. The Pacific Northwest National Laboratory (PNNL) is developing an unattended safeguards instrument concept, combining continuous aerosol particulate collection with uranium isotope assay, to provide timely analysis of enrichment levels within low enriched uranium facilities. This approach is based on laser vaporization of aerosol particulate samples, followed by wavelength tuned laser diode spectroscopy to characterize the uranium isotopic ratio through subtle differences in atomic absorption wavelengths. Environmental sampling (ES) media from an integrated aerosol collector is introduced into a small, reduced pressure chamber, where a focused pulsed laser vaporizes material from a 10 to 20-(micro)m diameter spot of the surface of the sampling media. The plume of ejected material begins as high-temperature plasma that yields ions and atoms, as well as molecules and molecular ions. We concentrate on the plume of atomic vapor that remains after the plasma has expanded and then cooled by the surrounding cover gas. Tunable diode lasers are directed through this plume and each isotope is detected by monitoring absorbance

  20. Activity Concentration for Surface Soil Samples Collected from Arrant, Qena, Egypt

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.; Moustafa, M.

    2010-01-01

    Soil samples were collected from four regions from Armant area. Qena, Upper Egypt for measure their natural radioactivity concentrations due to Ra-226, Th-232 and K-40 radionuclides. Thirty-Four surface soil samples were analyzed by using low-level gamma-spectrometric analysis. The average activity concentration for Ra-226 in (Bq/kg) in the collected soil samples were found to be 27.3 ±3.2, 11.4±1.09, 10.6±1.2, and 11.4±1.02 while the average value for Th-232 were 15.1±1.4, 11.1±0.77, 10.8 ± 0.72 and 11.1 ± 0.8 (Bq/kg) for soil samples from North, South, West and East. The corresponding average values for K-40 were 521.4±16.8, 463±14.8, 488.9±15.6 and 344.5±10.7 (Bq/kg), respectively. Based on radionuclides concentration in surface soil samples the radiological effects can be assessed

  1. Preparation of in-house calibration source for the use in radioactivity analysis of the environmental samples. Consideration of homogeneity

    International Nuclear Information System (INIS)

    Aba, A.; Ismaeel, A.

    2013-01-01

    An in-house reference material has been prepared in Kuwait Institute for Scientific Research radioecology laboratory, for quality control purposes of gamma spectrometer systems. The material contains a known amount of uranium ore reference material (prepared by the International Atomic Energy Agency and coded as IAEA-RGU-1) which is mixed with marine sediment collected from Kuwait bay. The IAEA-RGU-1 has been certified that it is in equilibrium state with the decay daughters, and stable to be used for quality control purposes. Nevertheless, the homogeneous distribution of the doped material with the prepared source should be verified. This has been examined using gamma spectrometry measurements in conjunction with analysis of variance statistical tools, Dixon, box plots and Grubbs tests. The calculated total uncertainty has been utilized to establish the recommended specific activity ranges of 226 Ra, 224 Th, 214 Pb, 214 Bi and 210 Pb radioisotopes in the prepared source. The obtained results showed that the estimated uncertainty arising from the sample inhomogeneity has a significant contribution in the total uncertainty. The stability control charts of the ultra-low background gamma spectrometry system demonstrated the suitability of the prepared material for the purpose of quality control. However, the emitted gamma-rays from the prepared source covers the required energy range for determination of natural and artificial radionuclides in different species of environmental samples such as marine sediment, soil samples, and samples contaminated by naturally occurring radioactive material produced by oil industry. In addition, the material might be used for system calibration in case its traceability is proven. The experimental data revealed the significance of the homogeneity in preparing environmental samples for radioactivity measurements; in particular when small sample quantities of environmental samples are required to be analyzed. (author)

  2. An international study of the performance of sample collection from patients

    NARCIS (Netherlands)

    Dzik, WH; Murphy, MF; Andreu, G; Heddle, N; Hogman, C; Kekomaki, R; Murphy, S; Shimizu, M; Smit Sibinga, C.T.

    2003-01-01

    Background and Objectives Collection of a blood sample from the correct patient is the first step in the process of safe transfusion. The aim of this international collaborative study was to assess the frequency of mislabelled and miscollected samples drawn for blood grouping. Materials and Methods

  3. Environmental monitoring for krypton-85

    International Nuclear Information System (INIS)

    Barber, D.E.

    1973-01-01

    85 Kr presents unique environmental monitoring problems because it does not react with other elements and compounds at normal ambient temperatures and pressures. However, elaborate means are available to manage the 85 Kr problem, but a simpler, inexpensive approach is required if monitoring is to be accomplished at many sampling locations. This work shows that environmental monitoring for 85 Kr is possible by collecting air samples in thin plastic bags, and counting the bags for beta particle activity. The direct counting of contained samples of this type makes it possible to detect concentrations less than the public MPC for 85 Kr. The bagged-sample technique is readily adaptable to any environmental monitoring station with power to run a low-volume air pump. The idea of counting the bagged-sample directly is a new, low-cost, approach to environmental gas monitoring which may have application in environmental, clinical, and industrial situations

  4. Dielectrophoretic sample preparation for environmental monitoring of microorganisms: Soil particle removal.

    Science.gov (United States)

    Fatoyinbo, Henry O; McDonnell, Martin C; Hughes, Michael P

    2014-07-01

    Detection of pathogens from environmental samples is often hampered by sensors interacting with environmental particles such as soot, pollen, or environmental dust such as soil or clay. These particles may be of similar size to the target bacterium, preventing removal by filtration, but may non-specifically bind to sensor surfaces, fouling them and causing artefactual results. In this paper, we report the selective manipulation of soil particles using an AC electrokinetic microfluidic system. Four heterogeneous soil samples (smectic clay, kaolinitic clay, peaty loam, and sandy loam) were characterised using dielectrophoresis to identify the electrical difference to a target organism. A flow-cell device was then constructed to evaluate dielectrophoretic separation of bacteria and clay in a continous flow through mode. The average separation efficiency of the system across all soil types was found to be 68.7% with a maximal separation efficiency for kaolinitic clay at 87.6%. This represents the first attempt to separate soil particles from bacteria using dielectrophoresis and indicate that the technique shows significant promise; with appropriate system optimisation, we believe that this preliminary study represents an opportunity to develop a simple yet highly effective sample processing system.

  5. Empirical insights and considerations for the OBT inter-laboratory comparison of environmental samples.

    Science.gov (United States)

    Kim, Sang-Bog; Roche, Jennifer

    2013-08-01

    Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  6. Equipment for collecting samples of radioactive solutions; Installation de prelevements d'echantillons de solutions radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Raggenbass, A.; Fradin, J.; Joubert, G.

    1958-12-03

    The authors present an equipment aimed at collecting samples of fission products to perform radio-chemical analysis. As the sample must have a total activity between 1 and 50 micro-Curie, this installation comprises a sampling system and a dilution device which aims at bringing the sample to the suitable activity. Samples are collected by means of needles. The sample reproducibility is discussed. The dilution device is described.

  7. Helium-3 mass spectrometry for low-level tritium analysis of environmental samples

    International Nuclear Information System (INIS)

    Surano, K.A.; Hudson, G.B.; Failor, R.A.; Sims, J.M.; Holland, R.C.; MacLean, S.C.; Garrison, J.C.

    1991-04-01

    Helium-3 ( 3 He) mass spectrometry for the analysis of low-level tritium ( 3 H) concentrations in environmental sample matrices was compared with conventional low-level β-decay counting methods. The mass-spectrometry method compared favorably, equaling or surpassing conventional decay-counting methods with respect to most criteria. Additional research and method refinements may make 3 He mass spectrometry the method of choice for routine, low-level to very-low-level 3 H measurements in a wide variety of environmental samples in the future

  8. Field sampling of soil pore water to evaluate trace element mobility and associated environmental risk

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Jimenez, Eduardo, E-mail: eduardo.moreno@uam.es [Departamento de Quimica Agricola, Universidad Autonoma de Madrid, 28049 Madrid (Spain); Beesley, Luke [James Hutton Institute, Craigiebuckler, Aberdeen AB15 8QH (United Kingdom); Lepp, Nicholas W. [35, Victoria Road, Formby, Liverpool L37 7DH (United Kingdom); Dickinson, Nicholas M. [Department of Ecology, Lincoln University, Lincoln 7647, PO Box 84 (New Zealand); Hartley, William [School of Computing, Science and Engineering, University of Salford, Cockcroft Building, Salford, M5 4WT (United Kingdom); Clemente, Rafael [Dep. of Soil and Water Conservation and Organic Waste Management, CEBAS-CSIC, Campus Universitario de Espinardo, PO Box 164, 30100 Espinardo, Murcia (Spain)

    2011-10-15

    Monitoring soil pollution is a key aspect in sustainable management of contaminated land but there is often debate over what should be monitored to assess ecological risk. Soil pore water, containing the most labile pollutant fraction in soils, can be easily collected in situ offering a routine way to monitor this risk. We present a compilation of data on concentration of trace elements (As, Cd, Cu, Pb, and Zn) in soil pore water collected in field conditions from a range of polluted and non-polluted soils in Spain and the UK during single and repeated monitoring, and propose a simple eco-toxicity test using this media. Sufficient pore water could be extracted for analysis both under semi-arid and temperate conditions, and eco-toxicity comparisons could be effectively made between polluted and non-polluted soils. We propose that in-situ pore water extraction could enhance the realism of risk assessment at some contaminated sites. - Highlights: > In situ pore water sampling successfully evaluates trace elements mobility in soils. > Field sampling proved robust for different soils, sites and climatic regimes. > Measurements may be directly related to ecotoxicological assays. > Both short and long-term monitoring of polluted lands may be achieved. > This method complements other widely used assays for environmental risk assessment. - In situ pore water sampling from a wide variety of soils proves to be a beneficial application to monitor the stability of pollutants in soils and subsequent risk through mobility.

  9. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  10. Distribution and Prevalence of Myxobolus cerebralis in Postfire Areas of Plumas National Forest: Utility of Environmental DNA Sampling.

    Science.gov (United States)

    Richey, Christine A; Kenelty, Kirsten V; Van Stone Hopkins, Kristina; Stevens, Brittany N; Martínez-López, Beatriz; Barnum, Samantha M; Hallett, Sascha L; Atkinson, Stephen D; Bartholomew, Jerri L; Soto, Esteban

    2018-04-30

    Myxobolus cerebralis is a myxozoan parasite and the etiological agent of whirling disease in salmonids. The parasite's life cycle involves waterborne spores and requires both a salmonid fish and the benthic freshwater oligochaete worm Tubifex tubifex (Oligochaeta: Tubificidae). Wildfires can lead to the erosion of fine sediments into stream channels and have been implicated as promoting environmental conditions that are suitable for the survival and success of T. tubifex, whose presence in turn can affect the prevalence of M. cerebralis. Analysis of environmental DNA (eDNA) has the potential to be a powerful tool for evaluating the presence of microorganisms, for which direct observation is impossible. We investigated the presence of M. cerebraliseDNA in river water and river sediment samples collected from areas affected by recent fire activity in Plumas National Forest, California. We compared eDNA loads in the environment to M. cerebralis infection in T. tubifex and sentinel-exposed Rainbow Trout Oncorhynchus mykiss and the presence of T. tubifex lineages in the same environment. For the latter, we developed a multiplex quantitative PCR assay for detection of T. tubifex lineages I, III, and V. Lineage IIIT. tubifex and M. cerebralis (eDNA as well as DNA extracted from fish and worm tissues) were detected only in samples obtained from areas affected by the Moonlight wildfire. The association between M. cerebralis infection in sentinel-exposed fish and eDNA detection in environmental samples only approached significance at a P-value of 0.056. However, given the difference in relative effort between the two sampling methods (host versus nonhost environment), our data suggest that eDNA sampling of water and substrate is a promising approach for surveillance of myxozoan fish parasites. © 2018 American Fisheries Society.

  11. Agri-Environmental Resource Management by Large-Scale Collective Action: Determining KEY Success Factors

    Science.gov (United States)

    Uetake, Tetsuya

    2015-01-01

    Purpose: Large-scale collective action is necessary when managing agricultural natural resources such as biodiversity and water quality. This paper determines the key factors to the success of such action. Design/Methodology/Approach: This paper analyses four large-scale collective actions used to manage agri-environmental resources in Canada and…

  12. Advanced Curation Activities at NASA: Implications for Astrobiological Studies of Future Sample Collections

    Science.gov (United States)

    McCubbin, F. M.; Evans, C. A.; Fries, M. D.; Harrington, A. D.; Regberg, A. B.; Snead, C. J.; Zeigler, R. A.

    2017-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. The Directive goes on to define Curation as including documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach. Here we briefly describe NASA's astromaterials collections and our ongoing efforts related to enhancing the utility of our current collections as well as our efforts to prepare for future sample return missions. We collectively refer to these efforts as advanced curation.

  13. 77 FR 38323 - Proposed Extension of Existing Information Collection; Respirable Coal Mine Dust Sampling

    Science.gov (United States)

    2012-06-27

    ... Information Collection; Respirable Coal Mine Dust Sampling AGENCY: Mine Safety and Health Administration... Sampling'' to more accurately reflect the type of information that is collected. Chronic exposure to... dust levels since 1970 and, consequently, the prevalence rate of black lung among coal miners, severe...

  14. Determination of multi-element in marine sediment samples collected in Angola by the k0-NAA technique

    International Nuclear Information System (INIS)

    Teixeira, M.C.P.; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Thanh Binh; Vuong Huu Tan

    2006-01-01

    The marine sediment samples were designed to collect in Angola for marine environmental pollution study. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on Dalat research reactor has been developed to determine of multi-element in the Angola marine sediment samples. The samples were irradiated in cell 7-1 for short- and middle-lived nuclides and rotary specimen rack for long-lived nuclides. The irradiation facilities were characterized for neutron spectrum parameters and post-activated samples were measured on the calibrated gamma-ray spectrometers using HPGe detectors. The analytical results for 9 marine sediment samples with 27 elements: Al, As, Br, Ca, Ce,Cl, Co, Cs, Dy, Fe, Hf, I, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Th, Ti, U, V and Zn in term of mean concentration, standard deviation and their content range are shown in the report. The analytical quality assurance was done by analysis of a Japan's certified reference material namely marine sediment NMIJ-CRM-7302a. These preliminary results revealed that the k 0 -NAA technique on the Dalat research reactor is a good analytical technique for determination of multi-element in the marine sediment samples. Some heavy metals and trace elements determined in this work possibly connected to the human activities at the sampling region. (author)

  15. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of ... Conclusion: Acceptability of self-sampling for HPV testing was similarly excellent in both groups despite their difference in terms ... cancer is the leading cause of death caused by cancer in.

  16. The analysis study of plutonium in the environmental sample by mass spectrum combined with isotopic dilution

    International Nuclear Information System (INIS)

    Han Jun; Fu Zhonghua; Mao Xingen; Meng Fanben

    2004-01-01

    The technology of the rhenium filament carbonization was used to increase the ionization efficiency in this paper. The plutonium in the environmental sample was analyzed by Mass Spectrum combined with isotope dilution. Analysis of the 239 Pu blank in the process: The analysis of 239 Pu from the chemical process was carried out in order to establish the influence of the 239 Pu introduced from the process. The analysis results were shown in Table 1 sample 1 was not gone through the process, sample 2 and sample 3 were gone through the process. It was clear that there was no influence of the 239 Pu from the process within the deviation. Results and Discussions: The environmental samples which were dealed with the chemical method were prepared the sample of mass spectrum, The atomic ratio of the 239 Pu and 242 Pu in the environmental samples was measured by Mass Spectrum. The atomic ratio in the tracer 242 Pu was 0.01476±0.00007.The results for nuclide content in environment were given in Table 2. The content of 239 Pu in the tracer was high, so the existing of 239 Pu in the environmental samples can be determined by the changing of the atomic ratio of 242 Pu to 239 Pu. It was clear that there was 239 Pu in the environmental samples except the cypress leaves-2 and the pine leaves-3 within the deviation, and the content of 239 Pu were given in Table 2. Conclusion: a. Plutonium was separated and purified from the impurity by the anion-exchange and the electrodeposition, it was possible to provide the eligible mass spectrum sample. b. The measurement of plutonium in the environmental samples was not influenced by the flow of the background in the experiment. c. As the technology of the rhenium carbonization was used to increase the ionization efficiency, the content of plutonium which was about 10 -13 g in the environmental sample could be quantitatively analyzed by Mass Spectrum combined with isotope dilution. (authors)

  17. Analytical Methodology for the Determination of Radium Isotopes in Environmental Samples

    International Nuclear Information System (INIS)

    2010-01-01

    Reliable, comparable and 'fit for purpose' results are an essential requirement for any decision based on analytical measurements. For the analyst, the availability of tested and validated analytical procedures is an extremely important tool for production of such analytical measurements. For maximum utility, such procedures should be comprehensive, clearly formulated, and readily available to both the analyst and the customer for reference. Since 2004, the environment programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. Measurements of radium isotopes are important for radiological and environmental protection, geochemical and geochronological investigations, hydrology, etc. The suite of isotopes creates and stimulates continuing interest in the development of new methods for determination of radium in various media. In this publication, the four most routinely used analytical methods for radium determination in biological and environmental samples, i.e. alpha spectrometry, gamma spectrometry, liquid scintillation spectrometry and mass spectrometry, are reviewed

  18. RELATIONSHIP BETWEEN ENVIRONMENTAL CONCERN AND GREEN PURCHASING BEHAVIOR

    OpenAIRE

    Kasim Tatic; Merima Cinjarevic

    2010-01-01

    The aim of this paper was to establish the relationship between environmental concern and consumers’ green purchasing behavior. A survey instrument was developed that used scales to measure general environmental beliefs (HEP-NEP general environmental beliefs questions) and consumer’s intention to buy environmental friendly products. Data were collected from a convenient (non-probability sampling method) sample of 150 consumers in the Sarajevo region. The results indicated that significant pos...

  19. Tritium analysis in environmental samples around Nuclear Power Plants and nationwide surveillance of radionuclides in some environmental samples(meat and drinking water)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2001-12-15

    12 kind of environmental samples such as soil, underground water, seawater, etc. around the Nuclear Power Plants(NPP) and surface seawater around the Korea peninsula were sampled, For the samples of rain, pine-needle, air, seawater, underground water, chinese cabbage, grain of rice and milk sampled around NPP, and surface seawater and rain sampled all around country, tritium concentration was measured, The tritium concentration in the tap water and the gamma activity in the domestic and imported beef that were sampled at ward in the large city in Korea(Seoul, Pusan, Taegu, Taejun, Inchun, Kwangju) were analyzed for the meat and drinking waters. As the results of analyzing, tritium concentration in rain and tap water were very low all around country, but a little higher around the NPP than general surrounding. At the Wolsung NPP, tritium concentration was descend according to distance from the stack. Tritium activity of surface seawater around the Korea peninsula was also, very low. The measured radioactive elements in the beef is the same as the radioactive elements on the earth surface.

  20. Recommended protocol for standardization in collecting and interpreting radiological environmental data

    International Nuclear Information System (INIS)

    Denham, D.H.; Kathren, R.L.

    1989-02-01

    Current reductions in ''allowable'' levels of radiation and radioactive materials in the environment and an increased public awareness of naturally occurring radioactive materials have reinforced the need for consistency in evaluating the radiological environment. A key concern is the identification and interpretation of environmental levels of radiation and radioactive materials resulting from nuclear facility operations. If these levels can be detected and their source(s) identified, then corrective actions can be taken to eliminate or greatly reduce the environmental impacts of the facility operations. In this paper we address the lack of definitive guidance necessary to determine incremental levels of significance (or insignificance), and we propose a series of protocols to achieve more consistent collection and interpretation of radiological environmental data. 8 refs

  1. Assessment of DDT levels in selected environmental media and biological samples from Mexico and Central America.

    Science.gov (United States)

    Pérez-Maldonado, Iván N; Trejo, Antonio; Ruepert, Clemens; Jovel, Reyna del Carmen; Méndez, Mónica Patricia; Ferrari, Mirtha; Saballos-Sobalvarro, Emilio; Alexander, Carlos; Yáñez-Estrada, Leticia; Lopez, Dania; Henao, Samuel; Pinto, Emilio R; Díaz-Barriga, Fernando

    2010-03-01

    Taking into account the environmental persistence and the toxicity of DDT, the Pan American Health Organization (PAHO) organized a surveillance program in Mesoamerica which included the detection of residual DDT in environmental (soil) and biological samples (fish tissue and children's blood). This program was carried out in communities from Mexico, Guatemala, El Salvador, Honduras, Nicaragua, Costa Rica and Panama. This paper presents the first report of that program. As expected, the results show that the levels for [summation operator] DDT in soil (outdoor or indoor) and fish samples in the majority of the locations studied are below guidelines. However, in some locations, we found children with high concentrations of DDT as in Mexico (mean level 50.2 ng/mL). Furthermore, in some communities and for some matrices, the DDT/DDE quotient is higher than one and this may reflect a recent DDT exposure. Therefore, more efforts are needed to avoid exposure and to prevent the reintroduction of DDT into the region. In this regard it is important to know that under the surveillance of PAHO and with the support of UNEP, a regional program in Mesoamerica for the collection and disposal of DDT and other POPs stockpiles is in progress. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  2. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.; Williams, Ryan J.; Isenhart, Thomas M.; Hofmockel, Kirsten S.

    2018-01-01

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

  3. Development of analytical methods for the separation of plutonium, americium, curium and neptunium from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Salminen, S.

    2009-07-01

    In this work, separation methods have been developed for the analysis of anthropogenic transuranium elements plutonium, americium, curium and neptunium from environmental samples contaminated by global nuclear weapons testing and the Chernobyl accident. The analytical methods utilized in this study are based on extraction chromatography. Highly varying atmospheric plutonium isotope concentrations and activity ratios were found at both Kurchatov (Kazakhstan), near the former Semipalatinsk test site, and Sodankylae (Finland). The origin of plutonium is almost impossible to identify at Kurchatov, since hundreds of nuclear tests were performed at the Semipalatinsk test site. In Sodankylae, plutonium in the surface air originated from nuclear weapons testing, conducted mostly by USSR and USA before the sampling year 1963. The variation in americium, curium and neptunium concentrations was great as well in peat samples collected in southern and central Finland in 1986 immediately after the Chernobyl accident. The main source of transuranium contamination in peats was from global nuclear test fallout, although there are wide regional differences in the fraction of Chernobyl-originated activity (of the total activity) for americium, curium and neptunium. The separation methods developed in this study yielded good chemical recovery for the elements investigated and adequately pure fractions for radiometric activity determination. The extraction chromatographic methods were faster compared to older methods based on ion exchange chromatography. In addition, extraction chromatography is a more environmentally friendly separation method than ion exchange, because less acidic waste solutions are produced during the analytical procedures. (orig.)

  4. Trace Elements Analysis of Archeological Brick Samples Collected from Different Historical Placs in Rajshahi Division

    International Nuclear Information System (INIS)

    Begum, Bilkis A.; Biswas, Shapan K.; Matin, Mohammed A.; Hoque, Mohammed M.; Hopke, Philip K.

    2007-01-01

    Twenty-nine brick samples were collected from different temples and palaces, namely Paharpur, Kumarpur, Gaurbari, Puthia and Natore in Rajshahi Division in Bangladesh. The samples were analyzed by X-ray Fluorescence (XRF) method. The elemental data sets have been analyzed in order to find out the general characteristics and any significant differences among the collected samples and identify the origin of these brick samples. Most of the crustal elements have enrichment factor (EF) values close to unity. Only Cu and Pb have high values that may come from painting as these have been collected from temples and palaces.(author)

  5. Assessment of the Capability of the NGDS Prototype to Replace the JBAIDS for Environmental Sample Analysis

    Science.gov (United States)

    2016-11-01

    Diagnostic System (JBAIDS) for environmental sample analysis. JUPITR ATD and USAF members analyzed environmental samples using the FilmArray...requires 60+ min for sample preparation, whereas the FilmArray system (right) uses highly multiplexed assay pouches that require ᝺ min for sample...supported the evaluation of the BDCoE by analyzing spiked DFU samples using the Joint Biological Agent Identification and Diagnostic System (JBAIDS) and the

  6. Migration in the Anthropocene: how collective navigation, environmental system and taxonomy shape the vulnerability of migratory species.

    Science.gov (United States)

    Hardesty-Moore, Molly; Deinet, Stefanie; Freeman, Robin; Titcomb, Georgia C; Dillon, Erin M; Stears, Keenan; Klope, Maggie; Bui, An; Orr, Devyn; Young, Hillary S; Miller-Ter Kuile, Ana; Hughey, Lacey F; McCauley, Douglas J

    2018-05-19

    Recent increases in human disturbance pose significant threats to migratory species using collective movement strategies. Key threats to migrants may differ depending on behavioural traits (e.g. collective navigation), taxonomy and the environmental system (i.e. freshwater, marine or terrestrial) associated with migration. We quantitatively assess how collective navigation, taxonomic membership and environmental system impact species' vulnerability by (i) evaluating population change in migratory and non-migratory bird, mammal and fish species using the Living Planet Database (LPD), (ii) analysing the role of collective navigation and environmental system on migrant extinction risk using International Union for Conservation of Nature (IUCN) classifications and (iii) compiling literature on geographical range change of migratory species. Likelihood of population decrease differed by taxonomic group: migratory birds were more likely to experience annual declines than non-migrants, while mammals displayed the opposite pattern. Within migratory species in IUCN, we observed that collective navigation and environmental system were important predictors of extinction risk for fishes and birds, but not for mammals, which had overall higher extinction risk than other taxa. We found high phylogenetic relatedness among collectively navigating species, which could have obscured its importance in determining extinction risk. Overall, outputs from these analyses can help guide strategic interventions to conserve the most vulnerable migrations.This article is part of the theme issue 'Collective movement ecology'. © 2018 The Author(s).

  7. A comparison of human papillomavirus testing of clinician-collected and self-collected samples during follow-up after screen-and-treat.

    Science.gov (United States)

    Taylor, Sylvia; Wang, Chunhui; Wright, Thomas C; Denny, Lynette; Kuhn, Louise

    2011-08-15

    Screen-and-treat cervical cancer prevention programs based on high-risk human papillomavirus (HPV) testing and cryotherapy have been shown to be effective in resource-limited settings. However, because cryotherapy is not 100% effective, follow-up is needed after treatment to detect post-treatment failures. We compared the test performances of high-risk HPV testing (Hybrid Capture 2) using self-collected and clinician-collected samples as well as cervical cytology for identifying cervical intraepithelial neoplasia grades 2 or 3 or invasive cervical cancer (CIN2+) among women who did (n=812) and did not (n=1858) undergo cryotherapy in a South African screen-and-treat trial. At 6 months after enrolment (and after cryotherapy, if performed), women were tested using all three screening methods and then underwent colposcopy/biopsy. A predefined subset of women (n=1,455) had extended follow-up with colposcopy/biopsy at 12 months. A total of 33 and 91 cases of CIN2+ were detected among treated and untreated women, respectively. The sensitivity of HPV testing using clinician-collected samples and cervical cytology did not differ by treatment status. HPV testing of clinician-collected samples detected the most cases of CIN2+ among both treated (85%) and untreated (91%) women (p=0.31). Cytology (at a cutoff of atypical squamous cells of undetermined significance or greater) detected 76% of cases among both treated and untreated women. However, the sensitivity of HPV testing using self-collected samples was significantly lower among treated versus untreated women (55% vs. 78%, p=0.01). HPV testing using self-collected vaginal specimens may be useful in primary screening but performs poorly for detecting post-treatment failures. Copyright © 2010 UICC.

  8. Multi-element analyses of Vietnamese environmental samples for radiation protection

    International Nuclear Information System (INIS)

    Mai, T.H.; Nguyen, T.B.; Nguyen, T.N.; Yoshida, S.

    2005-01-01

    The Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) were used for measuring 8 major and 27 trace elements in food and soil samples collected in Vietnam. The concentration of elements in food samples was different from different locations and also from different food groups. Depth profiles of the elements were discussed for soil samples. (author)

  9. Nontuberculous Mycobacteria Isolation from Clinical and Environmental Samples in Iran: Twenty Years of Surveillance

    Directory of Open Access Journals (Sweden)

    Ali Akbar Velayati

    2015-01-01

    Full Text Available Nontuberculous mycobacteria (NTM are opportunistic pathogens that are widely distributed in the environment. There is a lack of data on species distribution of these organisms from Iran. This study consists of a review of NTM articles published in Iran between the years 1992 and 2014. In this review, 20 articles and 14 case reports were identified. Among the 20 articles, 13 (65% studies focused on NTM isolates from clinical specimens, 6 (30% studies examined NTM isolates from environmental samples, and one (5% article included both clinical and environmental isolates. M. fortuitum (229/997; 23% was recorded as the most prevalent and rapid growing mycobacteria (RGM species in both clinical (28% and environmental (19% isolated samples (P < 0.05. Among slow growing mycobacteria (SGM, M. simiae (103/494; 21% demonstrated a higher frequency in clinical samples whereas in environmental samples it was M. flavescens (44/503; 9%. These data represent information from 14 provinces out of 31 provinces of Iran. No information is available in current published data on clinical or environmental NTM from the remaining 17 provinces in Iran. These results emphasize the potential importance of NTM as well as the underestimation of NTM frequency in Iran. NTM is an important clinical problem associated with significant morbidity and mortality in Iran. Continued research is needed from both clinical and environmental sources to help clinicians and researchers better understand and address NTM treatment and prevention.

  10. Nontuberculous Mycobacteria Isolation from Clinical and Environmental Samples in Iran: Twenty Years of Surveillance.

    Science.gov (United States)

    Velayati, Ali Akbar; Farnia, Parissa; Mozafari, Mohadese; Mirsaeidi, Mehdi

    2015-01-01

    Nontuberculous mycobacteria (NTM) are opportunistic pathogens that are widely distributed in the environment. There is a lack of data on species distribution of these organisms from Iran. This study consists of a review of NTM articles published in Iran between the years 1992 and 2014. In this review, 20 articles and 14 case reports were identified. Among the 20 articles, 13 (65%) studies focused on NTM isolates from clinical specimens, 6 (30%) studies examined NTM isolates from environmental samples, and one (5%) article included both clinical and environmental isolates. M. fortuitum (229/997; 23%) was recorded as the most prevalent and rapid growing mycobacteria (RGM) species in both clinical (28%) and environmental (19%) isolated samples (P < 0.05). Among slow growing mycobacteria (SGM), M. simiae (103/494; 21%) demonstrated a higher frequency in clinical samples whereas in environmental samples it was M. flavescens (44/503; 9%). These data represent information from 14 provinces out of 31 provinces of Iran. No information is available in current published data on clinical or environmental NTM from the remaining 17 provinces in Iran. These results emphasize the potential importance of NTM as well as the underestimation of NTM frequency in Iran. NTM is an important clinical problem associated with significant morbidity and mortality in Iran. Continued research is needed from both clinical and environmental sources to help clinicians and researchers better understand and address NTM treatment and prevention.

  11. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  12. Simultaneous PIXE and PIGE analyses of aerosol samples collected in urban areas

    International Nuclear Information System (INIS)

    Boni, C.; Caruso, E.; Cereda, E.; Marcazzan, G.M.; Redaelli, P.; Bacci, P.

    1988-01-01

    The paper concerns the simultaneous PIXE (Particle Induced X-ray Emission) and PIGE (Proton Induced Gamma-ray Emission) analyses of aerosol samples collected in urban areas. The results show that PIGE can detect Li, F, Na, Al, and Si in fly ashes and F, Na, Al and Si in atmospheric aerosol. The PIXE-PIGE technique has also been applied to 80 samples of atmospheric particular matter collected above Milan during the winter and summer months of 1986/7, and the average values of concentrations and enrichment factors are given for the detected elements. (U.K.)

  13. Oak Ridge Reservation: Annual Site Environmental Report for 2015

    Energy Technology Data Exchange (ETDEWEB)

    Rochelle, James [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rogers, Ben [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Roche, Paula R. [Y-12 National Security Complex, Oak Ridge, TN (United States); Hughes, Joan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Coffey, Mike [East Tennessee Technology Park (ETTP), Oak Ridge, TN (United States)

    2016-09-01

    The Oak Ridge Reservation Annual Site Environmental Report is prepared annually and presents summary environmental data to (1) characterize environmental performance, (2) summarize environmental occurrences reported during the year, (3) confirm compliance with environmental standards and requirements, and (4) highlight significant program activities. The report fulfills the requirement contained in DOE Order 231.1A, Environment, Safety and Health Reporting (DOE 2004) that an integrated annual site environmental report be prepared. The results summarized in this report are based on data collected prior to and through 2015. This report is not intended to nor does it present the results of all environmental monitoring associated with the ORR. Data collected for other site and regulatory purposes, such as environmental restoration/remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws and are referenced herein as appropriate. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the points of release to the environment; these measurements allow the quantification and official reporting of contaminant levels, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of direct measurements and collection and analysis of samples taken from the site and its environs exclusive of effluents; these activities provide information on contaminant concentrations in air, water, groundwater, soil, foods, biota, and other media. Environmental surveillance data support determinations regarding

  14. Compendium of Environmental Sustainability Indicator Collections: Rio to Johannesburg Dashboard of Sustainable Indicators

    Data.gov (United States)

    National Aeronautics and Space Administration — The Rio to Johannesburg Dashboard of Sustainable Development Indicators portion of the Compendium of Environmental Sustainability Indicator Collections contains 35...

  15. Assembly for collecting samples for purposes of identification or analysis and method of use

    Science.gov (United States)

    Thompson, Cyril V [Knoxville, TN; Smith, Rob R [Knoxville, TN

    2010-02-02

    An assembly and an associated method for collecting a sample of material desired to be characterized with diagnostic equipment includes or utilizes an elongated member having a proximal end with which the assembly is manipulated by a user and a distal end. In addition, a collection tip which is capable of being placed into contact with the material to be characterized is supported upon the distal end. The collection tip includes a body of chemically-inert porous material for binding a sample of material when the tip is placed into contact with the material and thereby holds the sample of material for subsequent introduction to the diagnostic equipment.

  16. Comparative multielement analyses of airborne particulate samples collected in various areas

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Matsuda, Yatsuka; Mizohata, Akira

    1973-01-01

    In order to grasp the characteristic features of the air pollution by particulates in various areas in Japan, multielement analyses by instrumental neutron activation analysis and radioisotope energy dispersive X-ray fluorescence analysis were applied to 31 airborne particulate samples collected in 15 different areas, and the analytical results obtained were compared with one another. All the samples were collected by so-called ''10 micron cut'' samplers, the collection efficiency of which is considered to be 50% at 8μ and nearly zero beyond 10μ. Among the areas in question there are clean seaside areas, heavily industrialized areas, small cities along the Inland Sea or the Pacific Ocean around which industrialization is progressing, a small city having only a big iron work, an area famous for its ceramic industry and so on. The atmospheres over them were found to be quite different not only in pollution extent but also in pollution pattern. (auth.)

  17. Environmental Monitoring Plan, Revision 5

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, G M; Blake, R G; Bertoldo, N A; Campbell, C G; Coty, J; Folks, K; Grayson, A R; Jones, H E; Nelson, J C; Revelli, M A; Wegrecki, T; Williams, R A; Wilson, K

    2010-01-27

    The purpose of environmental monitoring is to promote the early identification of, and response to, potential adverse environmental impacts associated with Lawrence Livermore National Laboratory (LLNL) operations. Environmental monitoring supports the Integrated Safety Management System (ISMS), International Organization for Standardization (ISO) 14001 Environmental Management Systems standard, and U. S. Department of Energy (DOE) Order 450.1A, Environmental Protection Program. Specifically, in conformance with DOE Order 450.1A, Attachment 1, paragraph 1(b)(5), environmental monitoring enables LLNL to detect, characterize, and respond to releases from LLNL activities; assess impacts; estimate dispersal patterns in the environment; characterize the pathways of exposure to members of the public; characterize the exposures and doses to individuals and to the population; and to evaluate the potential impacts to the biota in the vicinity of LLNL. Environmental monitoring also serves to demonstrate compliance with permits and other regulatory requirements. The Environmental Monitoring Plan (EMP) addresses the sample collection and analytical work supporting environmental monitoring to ensure the following: (1) A consistent system for collecting, assessing, and documenting environmental data of known and documented quality. (2) A validated and consistent approach for sampling and analysis of samples to ensure laboratory data meets program-specific needs and requirements within the framework of a performance-based approach for analytical laboratory work. (3) An integrated sampling approach to avoid duplicative data collection. Until its cancellation in January 2003, DOE Order 5400.1 required the preparation of an environmental monitoring plan. Neither DOE Order 450.1A nor the ISO 14001 standard are as prescriptive as DOE Order 5400.1, in that neither expressly requires an EMP. However, LLNL continues to prepare the EMP because it provides an organizational framework for

  18. Environmental and emergency response capabilities of Los Alamos Scientific Laboratory's radiological air sampling program

    International Nuclear Information System (INIS)

    Gunderson, T.C.

    1980-05-01

    Environmental and emergency response radiological air sampling capabilities of the Environmental Surveillance Group at Los Alamos Scientific Laboratory are described. The air sampling program provides a supplementary check on the adequacy of containment and effluent controls, determines compliance with applicable protection guides and standards, and assesses potential environmental impacts on site environs. It also allows evaluation of potential individual and total population doses from airborne radionuclides that may be inhaled or serve as a source of external radiation. The environmental program is sufficient in scope to detect fluctuations and long-term trends in atmospheric levels of radioactivity originating onsite. The emergency response capabilities are designed to respond to both onsite unplanned releases and atmospheric nuclear tests

  19. Automated image analysis for quantitative fluorescence in situ hybridization with environmental samples.

    Science.gov (United States)

    Zhou, Zhi; Pons, Marie Noëlle; Raskin, Lutgarde; Zilles, Julie L

    2007-05-01

    When fluorescence in situ hybridization (FISH) analyses are performed with complex environmental samples, difficulties related to the presence of microbial cell aggregates and nonuniform background fluorescence are often encountered. The objective of this study was to develop a robust and automated quantitative FISH method for complex environmental samples, such as manure and soil. The method and duration of sample dispersion were optimized to reduce the interference of cell aggregates. An automated image analysis program that detects cells from 4',6'-diamidino-2-phenylindole (DAPI) micrographs and extracts the maximum and mean fluorescence intensities for each cell from corresponding FISH images was developed with the software Visilog. Intensity thresholds were not consistent even for duplicate analyses, so alternative ways of classifying signals were investigated. In the resulting method, the intensity data were divided into clusters using fuzzy c-means clustering, and the resulting clusters were classified as target (positive) or nontarget (negative). A manual quality control confirmed this classification. With this method, 50.4, 72.1, and 64.9% of the cells in two swine manure samples and one soil sample, respectively, were positive as determined with a 16S rRNA-targeted bacterial probe (S-D-Bact-0338-a-A-18). Manual counting resulted in corresponding values of 52.3, 70.6, and 61.5%, respectively. In two swine manure samples and one soil sample 21.6, 12.3, and 2.5% of the cells were positive with an archaeal probe (S-D-Arch-0915-a-A-20), respectively. Manual counting resulted in corresponding values of 22.4, 14.0, and 2.9%, respectively. This automated method should facilitate quantitative analysis of FISH images for a variety of complex environmental samples.

  20. Characteristics of the samples in the FNG fission deposit collection

    Energy Technology Data Exchange (ETDEWEB)

    Meadows, J.W.

    1990-12-01

    Information concerning the samples in the Fast Neutron Generator (FNG) Group's fission deposit collection has been assembled. This includes the physical dimensions, isotopic analyses, half-lives, alpha emission rates specific activities and deposit weights. 10 refs., 9 figs., 5 tabs.

  1. Measurement of extremely (2) H-enriched water samples by laser spectrometry: application to batch electrolytic concentration of environmental tritium samples.

    Science.gov (United States)

    Wassenaar, L I; Kumar, B; Douence, C; Belachew, D L; Aggarwal, P K

    2016-02-15

    Natural water samples artificially or experimentally enriched in deuterium ((2) H) at concentrations up to 10,000 ppm are required for various medical, environmental and hydrological tracer applications, but are difficult to measure using conventional stable isotope ratio mass spectrometry. Here we demonstrate that off-axis integrated cavity output (OA-ICOS) laser spectrometry, along with (2) H-enriched laboratory calibration standards and appropriate analysis templates, allows for low-cost, fast, and accurate determinations of water samples having δ(2) HVSMOW-SLAP values up to at least 57,000 ‰ (~9000 ppm) at a processing rate of 60 samples per day. As one practical application, extremely (2) H-enriched samples were measured by laser spectrometry and compared to the traditional (3) H Spike-Proxy method in order to determine tritium enrichment factors in the batch electrolysis of environmental waters. Highly (2) H-enriched samples were taken from different sets of electrolytically concentrated standards and low-level (tritium samples, and all cases returned accurate and precise initial low-level (3) H results. The ability to quickly and accurately measure extremely (2) H-enriched waters by laser spectrometry will facilitate the use of deuterium as a tracer in numerous environmental and other applications. For low-level tritium operations, this new analytical ability facilitated a 10-20 % increase in sample productivity through the elimination of spike standards and gravimetrics, and provides immediate feedback on electrolytic enrichment cell performance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. A comparison of results for samples collected with bailers constructed of different materials

    International Nuclear Information System (INIS)

    Thomey, N.; Ogle, R.; Jackson, J.

    1992-01-01

    A bailer is one of the most common sampling devices used to collect ground water samples. Bailers constructed from various materials are available; teflon, polyvinyl chloride (PVC), polyethylene, and stainless steel are all commonly used. It is widely recognized that sample results can be affected by the material from which the bailer is constructed. Teflon and stainless steel are usually recommended based upon their inert properties. The cost of these bailers is significantly higher than other types. For the purposes of petroleum storage tank investigations, sampling devices that would not compromise sample quality but be more economical than teflon or stainless steel would be especially desirable. Water samples were collected using the different types of bailers; teflon, stainless steel, PVC, and polyethylene. Split samples were analyzed for benzene, toluene, ethylbenzene, total xylenes, and Total Petroleum Hydrocarbons. The analytical results were compared to determine if differences were due to normal analytical variances or due to interaction of the sample with the sampling device. No difference was noted in the results which were obtained

  3. Application of bar codes to the automation of analytical sample data collection

    International Nuclear Information System (INIS)

    Jurgensen, H.A.

    1986-01-01

    The Health Protection Department at the Savannah River Plant collects 500 urine samples per day for tritium analyses. Prior to automation, all sample information was compiled manually. Bar code technology was chosen for automating this program because it provides a more accurate, efficient, and inexpensive method for data entry. The system has three major functions: sample labeling is accomplished at remote bar code label stations composed of an Intermec 8220 (Intermec Corp.) interfaced to an IBM-PC, data collection is done on a central VAX 11/730 (Digital Equipment Corp.). Bar code readers are used to log-in samples to be analyzed on liquid scintillation counters. The VAX 11/730 processes the data and generates reports, data storage is on the VAX 11/730 and backed up on the plant's central computer. A brief description of several other bar code applications at the Savannah River Plant is also presented

  4. An Environmentally Friendly, Cost-Effective Determination of Lead in Environmental Samples Using Anodic Stripping Voltammetry

    Science.gov (United States)

    Goldcamp, Michael J.; Underwood, Melinda N.; Cloud, Joshua L.; Harshman, Sean

    2008-01-01

    Contamination of the environment with heavy metals such as lead presents many health risks. Simple, effective, and field-portable methods for the measurement of toxic metals in environmental samples are vital tools for evaluating the risks that these contaminants pose. This article describes the use of new developments in anodic stripping…

  5. Improved optimum condition for recovery and measurement of 210Po in environmental samples

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Norfaizal Mohamed; Nik Azlin Nik Ariffin; Abdul Kadir Ishak

    2012-01-01

    An improved laboratory technique for measurement of polonium-210( 210 Po) in environmental samples has been developed in Radiochemistry and Environmental Laboratory (RAS), Malaysian Nuclear Agency. To further improve this technique, a study with the objectives to determine the optimum conditions for 210 Po deposition and; evaluate the accuracy and precision results for the determination of 210 Po in environmental samples was carried-out. Polonium-210 which is an alpha emitter obtained in acidic solution through total digestion and dissolution of samples has been efficiently plated onto one side of the silver disc in the spontaneous plating process for measurement of its alpha activity. The optimum conditions for deposition of 210 Po were achieved using hydrochloric acid (HCl) media at acidity of 0.5 M with the presence of 1.0 gram hydroxyl ammonium chloride and the plating temperature at 90 degree Celsius. The plating was carried out in 80 ml HCl solution (0.5 M) for 4 hours. The recorded recoveries obtained using 209 Po tracers in the CRM IAEA-385 and environmental samples were 85 % - 98% whereby the efficiency of the new technique is a distinct advantage over the existing techniques. Therefore, optimization of deposition parameters is a prime importance to achieve accuracy and precision results as well as economy and time saving. (author)

  6. Intrepretation of work area and environmental sampling

    International Nuclear Information System (INIS)

    Ritter, P.D.; Alvarez, J.L.; Novick, V.J.

    1985-01-01

    Meaningful interpretation of widely variable airborne contamination measurements is a difficult problem. Exposure limits, action levels, etc., are rigid interpretations of inherently variable environmental or workplace conditions, and are useful for control and regulatory compliance evaluations. Such limits force actions to reduce contamination, but have limited usefulness as benchmarks for evaluating isolated or nonrepresentative measurements. This paper deals with interpretation of exposure based on nonrepresentative sampling. The use of hard limits for interpreting measurements of legal record simplifies judgment during cursory audits; more aggressive questioning of the validity of these records may effectively invalidate them in a courtroom situation

  7. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    Science.gov (United States)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in

  8. Lepidosaurian diversity in the Mesozoic-Palaeogene: the potential roles of sampling biases and environmental drivers

    Science.gov (United States)

    Cleary, Terri J.; Benson, Roger B. J.; Evans, Susan E.; Barrett, Paul M.

    2018-03-01

    Lepidosauria is a speciose clade with a long evolutionary history, but there have been few attempts to explore its taxon richness through time. Here we estimate patterns of terrestrial lepidosaur genus diversity for the Triassic-Palaeogene (252-23 Ma), and compare observed and sampling-corrected richness curves generated using Shareholder Quorum Subsampling and classical rarefaction. Generalized least-squares regression (GLS) is used to investigate the relationships between richness, sampling and environmental proxies. We found low levels of richness from the Triassic until the Late Cretaceous (except in the Kimmeridgian-Tithonian of Europe). High richness is recovered for the Late Cretaceous of North America, which declined across the K-Pg boundary but remained relatively high throughout the Palaeogene. Richness decreased following the Eocene-Oligocene Grande Coupure in North America and Europe, but remained high in North America and very high in Europe compared to the Late Cretaceous; elsewhere data are lacking. GLS analyses indicate that sampling biases (particularly, the number of fossil collections per interval) are the best explanation for long-term face-value genus richness trends. The lepidosaur fossil record presents many problems when attempting to reconstruct past diversity, with geographical sampling biases being of particular concern, especially in the Southern Hemisphere.

  9. Environmental surveillance at Hanford for CY-1976

    International Nuclear Information System (INIS)

    Fix, J.J.; Blumer, P.J.; Hoenes, G.R.; Bramson, P.E.

    1977-04-01

    Environmental data collected during 1976 show continued compliance by Hanford with all applicable state and federal regulations. Data were collected for most environmental media including air, Columbia River water, external radiation, foodstuffs (milk, meat, eggs, poultry, and produce), and wildlife (deer, fish, game birds, and oysters from Willapa Bay), as well as a few soil and vegetation samples. The data are summarized

  10. Rapid methods for measuring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    Perkins, Richard W.

    1995-01-01

    The application of ICP/mass spectrometry for the isotopic analysis of environmental samples, the use of drum assayers for measuring radionuclides in food and a rapid procedure for the measurement of the transuranic elements and thorium, performed at the Pacific Northwest Laboratory are discussed

  11. Determination of 90Sr in environmental samples by microwave assisted digestion - chromatographic separation

    International Nuclear Information System (INIS)

    Torres, J.M.; Llaurado, M.; Rauret, G.

    1998-01-01

    The stages involved in the determination of 90 Sr in environmental samples are: sample attack, radiochemical separation (of both 90 Sr and its progeny 90 Y) and measurement. For the determination of 90 Sr, the introduction of microwave-assisted digestion methods has improved acid attack by drastically decreasing both digestion time and the volume of acidic reagents. Recent studies describe many applications of microwave-assisted methods for the determination of inorganic and organometallic compounds in several matrices. We have recently studied the microwave-assisted digestion of soils for the 90 Sr determination. The presented work extends the application of microwaves for the 90 Sr determination to other environmental samples such as sediments, vegetation and milk. An open-focused microwave system, which accepts large samples intakes usually required for radioanalytical chemistry due to the low level content of radionuclides in environmental samples, was used. This system can handle up to 10 g of sample intake which, in many cases, is enough to have acceptable limits of detection. Different digestion procedures are optimised for each matrix studied, paying special attention to the microwave power, the time of digestion and the volume of acidic reagents. Once the sample is in solution a new separation procedure using a specific resin -Sr.Spec- is applied and the measurement is performed by liquid scintillation. The results obtained are compared with a previously optimised method based on liquid-liquid extraction of 90 Y and Cerenkov radiation measurement

  12. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE

  13. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE.

  14. Sampling marine sediments for radionuclide monitoring

    International Nuclear Information System (INIS)

    Papucci, C.

    1997-01-01

    A description of the most common devices used for sampling marine sediments are reported. The systems are compared to evidence their intrinsic usefulness, for collecting samples in different environmental conditions or with different scientific objectives. Perturbations and artifacts introduced during the various steps of the sampling procedure are also reviewed, and suggestions are proposed for obtaining and preserving, as much as possible, the representativeness of the sediment samples. (author)

  15. Sources of variability in collection and preparation of paint and lead-coating samples.

    Science.gov (United States)

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  16. Three-phase double-arc plasma for spectrochemical analysis of environmental samples.

    Science.gov (United States)

    Mohamed, M M; Ghatass, Z F; Shalaby, E A; Kotb, M M; El-Raey, M

    2000-12-01

    A new instrument, which uses a three-phase current to support a double-arc argon plasma torch for evaporation, atomization and excitation of solid or powder samples, is described. The sampling arc is ignited between the first and second electrode while the excitation arc is ignited between the second and third electrode. Aerosol generated from the sample (first electrode) is swept by argon gas, through a hole in the second electrode (carbon tubing electrode), into the excitation plasma. A tangential stream of argon gas is introduced through an inlet orifice as a coolant gas for the second electrode. This gas stream forces the excitation arc discharge to rotate reproducibly around the electrode surface. Discharge rotation increases the stability of the excitation plasma. Spectroscopic measurements are made directly in the current-carrying region of the excitation arc. An evaluation of each parameter influencing the device performance was performed. Analytical calibration curves were obtained for Fe, Al, K, and Pb. Finally, the present technique was applied for the analysis of environmental samples. The present method appears to have significant, low cost analytical utility for environmental measurements.

  17. Methodology of testing environmental samples from the area surrounding radioactive waste deposits

    International Nuclear Information System (INIS)

    Kropikova, S.; Pastuchova, D.

    1979-01-01

    Methods are described of environmental sample investigation in the area surrounding radioactive waste deposits, namely monitoring ground water, surface water, sediments, water flows and catchments, vegetation and soil. Methods of sample preparation, and methods of radionuclides determination in mixtures are also discussed, as are spot activity measurement methods. (author)

  18. Mapping of marine benthic invertebrates in the Oslofjord and the Skagerrak: sampling data of museum collections from 1950-1955 and from recent investigations

    Directory of Open Access Journals (Sweden)

    Eivind Oug

    2015-12-01

    Full Text Available Data from large sampling programmes for the mapping of marine invertebrates in the Oslofjord, Norway, and the Skagerrak, spanning more than six decades, are compiled and digitized to provide easy access in modern data repositories. Two sampling programmes undertaken in the period 1950–55 are still the most extensive mapping of marine benthic fauna in the area. Information from a total of more than 900 localities, or sampling events, covering all benthic habitats in the Oslofjord and coastal waters to Kvitsøy in Rogaland county, have been carefully digitized from field notes, original sea charts, and primary observations from sample handling in the field. Geographical coordinates referred to WGS84 chart datum have been fixed with a general accuracy of 20 m in the Oslofjord and 100–250 m in coastal areas, based on precise map sketches with cross-bearings to land objects and chart annotations. Most samples were collected using triangular, Agassiz and lightweight dredges. The collected material has been deposited in the collections of the Natural History Museum, University of Oslo. Two recent projects, ‘Polyskag’ and ‘Bioskag’ (2006–2014, are briefly described. The projects focused on the diversity of marine bristle worms (Polychaeta, inter alia providing material for molecular genetic analyses. Type localities for early described species and generally understudied biotopes were visited. The data from the 1950s, together with recent studies, constitute a considerable resource for studies of biodiversity, facilitated through the sharing of species records from the museum collections in modern data repositories. The accurate positioning of sampling localities in the 1950s is of particular value for documenting species distributions over long time spans, thus providing a reference base for studying present and future species changes and assessing the effects of human influence and environmental changes in the Oslofjord and the Skagerrak.

  19. Filtration recovery of extracellular DNA from environmental water samples

    Science.gov (United States)

    qPCR methods are able to analyze DNA from microbes within hours of collecting water samples, providing the promptest notification and public awareness possible when unsafe pathogenic levels are reached. Health risk, however, may be overestimated by the presence of extracellular ...

  20. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  1. A simple method of correcting for variation of sample thickness in the determination of the activity of environmental samples by gamma spectrometry

    International Nuclear Information System (INIS)

    Galloway, R.B.

    1991-01-01

    Gamma ray spectrometry is a well established method of determining the activity of radioactive components in environmental samples. It is usual to maintain precisely the same counting geometry in measurements on samples under investigation as in the calibration measurements on standard materials of known activity, thus avoiding perceived uncertainties and complications in correcting for changes in counting geometry. However this may not always be convenient if, as on some occasions, only a small quantity of sample material is available for analysis. A procedure which avoids re-calibration for each sample size is described and is shown to be simple to use without significantly reducing the accuracy of measurement of the activity of typical environmental samples. The correction procedure relates to the use of cylindrical samples at a constant distance from the detector, the samples all having the same diameter but various thicknesses being permissible. (author)

  2. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  3. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    Science.gov (United States)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return

  4. Environmental DNA from Seawater Samples Correlate with Trawl Catches of Subarctic, Deepwater Fishes.

    Directory of Open Access Journals (Sweden)

    Philip Francis Thomsen

    Full Text Available Remote polar and deepwater fish faunas are under pressure from ongoing climate change and increasing fishing effort. However, these fish communities are difficult to monitor for logistic and financial reasons. Currently, monitoring of marine fishes largely relies on invasive techniques such as bottom trawling, and on official reporting of global catches, which can be unreliable. Thus, there is need for alternative and non-invasive techniques for qualitative and quantitative oceanic fish surveys. Here we report environmental DNA (eDNA metabarcoding of seawater samples from continental slope depths in Southwest Greenland. We collected seawater samples at depths of 188-918 m and compared seawater eDNA to catch data from trawling. We used Illumina sequencing of PCR products to demonstrate that eDNA reads show equivalence to fishing catch data obtained from trawling. Twenty-six families were found with both trawling and eDNA, while three families were found only with eDNA and two families were found only with trawling. Key commercial fish species for Greenland were the most abundant species in both eDNA reads and biomass catch, and interpolation of eDNA abundances between sampling sites showed good correspondence with catch sizes. Environmental DNA sequence reads from the fish assemblages correlated with biomass and abundance data obtained from trawling. Interestingly, the Greenland shark (Somniosus microcephalus showed high abundance of eDNA reads despite only a single specimen being caught, demonstrating the relevance of the eDNA approach for large species that can probably avoid bottom trawls in most cases. Quantitative detection of marine fish using eDNA remains to be tested further to ascertain whether this technique is able to yield credible results for routine application in fisheries. Nevertheless, our study demonstrates that eDNA reads can be used as a qualitative and quantitative proxy for marine fish assemblages in deepwater oceanic

  5. DNA typing of ancient parasite eggs from environmental samples identifies human and animal worm infections in viking-age settlement

    DEFF Research Database (Denmark)

    Søe, Martin Jensen; Nejsum, Peter; Fredensborg, Brian Lund

    2015-01-01

    Ancient parasite eggs were recovered from environmental samples collected at a Viking-age settlement in Viborg, Denmark, dated 1018-1030 A.D. Morphological examination identified Ascaris sp., Trichuris sp., and Fasciola sp. eggs, but size and shape did not allow species identification. By carefully...... selecting genetic markers, PCR amplification and sequencing of ancient DNA (aDNA) isolates resulted in identification of: the human whipworm, Trichuris trichiura, using SSUrRNA sequence homology; Ascaris sp. with 100% homology to cox1 haplotype 07; and Fasciola hepatica using ITS1 sequence homology...

  6. Application of ion chromatography for the determination of inorganic ions, especially thiocyanates, in human semen samples as biomarkers of environmental tobacco smoke exposure.

    Science.gov (United States)

    Demkowska, Ilona; Polkowska, Żaneta; Kiełbratowska, Bogumiła; Namieśnik, Jacek

    2010-11-01

    Tobacco smoking constitutes a significant source of indoor air pollution. Various chemical compounds that are emitted during tobacco smoking can have a direct cytotoxic effect on spermatozoa by damaging DNA. There is some evidence that tobacco smoking in men could affect male fertility. The goals of this study were to find relationships between thiocyanates (as biomarkers of environmental tobacco smoke exposure) and other inorganic ions in human semen samples and present the effectiveness of the proposed sample preparation procedure combined with ion chromatography technique for the determination of inorganic ions, especially thiocyanates, in human semen samples collected from heavy, moderate, and passive smokers, as well as nonsmoking individuals.

  7. Wildlife specimen collection, preservation, and shipment

    Science.gov (United States)

    White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.

    2015-01-01

    Specimens are used to provide supporting information leading to the determination of the cause of disease or death in wildlife and for disease monitoring or surveillance. Commonly used specimens for wildlife disease investigations include intact carcasses, tissues from carcasses, euthanized or moribund animals, parasites, ingested food, feces, or environmental samples. Samples from live animals or the environment (e.g., contaminated feed) in the same vicinity as a mortality event also may be helpful. The type of specimen collected is determined by availability of samples and biological objectives. Multiple fresh, intact carcasses from affected species are the most useful in establishing a cause for a mortality event. Submission of entire carcasses allows observation of gross lesions and abnormalities, as well as disease testing of multiple tissues. Samples from live animals may be more appropriate when sick animals cannot be euthanized (e.g., threatened or endangered species) or for research and monitoring projects examining disease or agents circulating in apparently healthy animals or those not exhibiting clinical signs. Samples from live animals may include collections of blood, hair, feathers, feces, or ectoparasites, or samples obtained by swabbing lesions or orifices. Photographs and videos are useful additions for recording field and clinical signs and conveying conditions at the site. Collection of environmental samples (e.g., feces, water, feed, or soil) may be appropriate when animals cannot be captured for sampling or the disease agent may persist in the environment. If lethal collection is considered necessary, biologists should refer to the policies, procedures, and permit requirements of their institution/facility and the agency responsible for species management (U.S. Fish and Wildlife Service or State natural resource agency) prior to use in the field. If threatened or endangered species are found dead, or there is evidence of illegal take, field

  8. Assessment of the environmental risk perceptions and environmental attitudes of nursing students.

    Science.gov (United States)

    Sayan, Betül; Kaya, Hatice

    2016-12-01

    This is a descriptive study examining nursing students' perceptions of the environmental risks and their environmental attitudes. The study population comprised 2364 nursing students studying at universities in Istanbul in the fall semester of the 2012-2013 academic year. The sampling group was formed by 778 students which were selected by a stratified random sampling procedure. The data were collected using "The Student Personal Information Form", "The Environmental Risk Perception Scale" and "The Environmental Attitudes Scale". The students' mean score on perceptions of environmental risk was 6.04 ± 0.81(min 2.56; max 7.00) and the mean score of their environmental attitudes was 4.02 ± 0.47(min 2.28; max 5.00). It was determined that factors such as gender, interest in environmental issues, endorsement of the college course on environment as necessary, and participation in an environmental activity and awareness of non-government environmental organizations affected the environmental risk perception and environmental attitudes. A moderate positive relationship (r = 0.366, p environmental risk perceptions and their environmental attitudes. Effective environmental education should be planned at all stages of the nursing education.

  9. The environmental impact of poverty: evidence from firewood collection in rural Nepal.

    Science.gov (United States)

    Baland, Jean-Marie; Bardhan, Pranab; Das, Sanghamitra; Mookherjee, Dilip; Sarkar, Rinki

    2010-01-01

    We investigate determinants of household firewood collection in rural Nepal, using 1995-96 and 2002-3 World Bank Living Standards Measurement Survey (LSMS) data. We incorporate village fixed effects, endogenous censoring, measurement error in living standards and heterogeneous effects of different household assets. We find no evidence in favor of the poverty-environment hypothesis. The evidence for the environmental Kuznets curve depends on the precise measure of living standards and time period studied. Firewood collections fall with a transition to modern occupations and rise with increasing population and household division. The local interhousehold collection externality is negligible, indicating that policy interventions are justified only by ecological considerations or nonlocal spillovers.

  10. Results of tritium measurement in environmental samples and drainage

    International Nuclear Information System (INIS)

    Koike, Ryoji; Hirai, Yasuo

    1983-01-01

    In Ibaraki prefecture, the tritium concentration in the drainage from the nuclear facilities has been measured since 1974. Then, with the start of operation of the fuel reprocessing plant in 1977, the tritium concentration in environmental samples was to be measured also in order to examine the effect of the drainage on the environment. The results of the tritium measurement in Ibaraki prefecture up to about 1980 are described: sampling points, sampling and measuring methods, the tritium concentration in the drainage, air, inland water and seawater, respectively. The drainages have been taken from Japan Atomic Power Company, Japan Atomic Energy Research Institute, and Power Reactor and Nuclear Fuel Development Corporation (with the fuel reprocessing plant). The samples of air, inland water and seawater have been taken in the areas concerned. The tritium concentration was measured by a low-background liquid scintillation counter. The measured values in the environment have been generally at low level, not different from other areas. (Mori, K.)

  11. Nicotine Contamination in Particulate Matter Sampling

    Directory of Open Access Journals (Sweden)

    Eric Garshick

    2009-02-01

    Full Text Available We have addressed potential contamination of PM2.5 filter samples by nicotine from cigarette smoke. We collected two nicotine samples – one nicotine sampling filter was placed in-line after the collection of PM2.5 and the other stood alone. The overall correlation between the two nicotine filter levels was 0.99. The nicotine collected on the “stand-alone” filter was slightly greater than that on the “in-line” filter (mean difference = 1.10 μg/m3, but the difference was statistically significant only when PM2.5 was low (≤ 50 μg/m3. It is therefore important to account for personal and secondhand smoke exposure while assessing occupational and environmental PM.

  12. Identification and assay of radionuclides in the environmental samples following Chernobyl reactor accident

    International Nuclear Information System (INIS)

    Prakash, S.

    1987-01-01

    In India radioactivity was detected from 2 May 1986 onwards. A variety of samples were assayed for radionuclides in the environmental samples originating from the Chernobyl reactor accident. These are: Cotton swipe samples from aircrafts, air filters, milk, goat thyroids, grass, vegetables and tap waters. The results are presented in the paper

  13. BP Spill Sampling Data April-September 2010

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset provides all of the sampling data from the the British Petroleum Deepwater Horizon Rig Explosion Emergency Response. The data were collected between...

  14. Survey of elemental concentrations in lichen samples collected from Sao Paulo State

    International Nuclear Information System (INIS)

    Saiki, M.; Horimoto, L.K.; Vasconcellos, M.B.A.; Coccaro, D.M.B.; Marcelli, M.P.

    2001-01-01

    Samples of the lichen Canoparmelia texana collected in seven different sites of Sao Paulo State and one site of the Parana State were analysed by neutron activation analysis in order to obtain information on the air quality in these regions and also to select a region of interest for the evaluation of baseline level of elements in lichen species. Concentrations of the elements Al, As, Br, Ca, Cd, Cl, Co, Cs, Fe, Hf, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Ti, Th, U, V, Zn and lanthanides were determined and a preliminary comparisons was made between the results obtained for samples collected in different sites. (author)

  15. Multisite Direct Determination of the Potential for Environmental Contamination of Urine Samples Used for Diagnosis of Sexually Transmitted Infections.

    Science.gov (United States)

    Andersson, Patiyan; Tong, Steven Y C; Lilliebridge, Rachael A; Brenner, Nicole C; Martin, Louise M; Spencer, Emma; Delima, Jennifer; Singh, Gurmeet; McCann, Frances; Hudson, Carolyn; Johns, Tracy; Giffard, Philip M

    2014-09-01

    The detection of a sexually transmitted infection (STI) agent in a urine specimen from a young child is regarded as an indicator of sexual contact. False positives may conceivably arise from the transfer of environmental contaminants in clinic toilet or bathroom facilities into urine specimens. The potential for contamination of urine specimens with environmental STI nucleic acid was tested empirically in the male and female toilets or bathrooms at 10 Northern Territory (Australia) clinics, on 7 separate occasions at each. At each of the 140 experiments, environmental contamination with Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis nucleic acid contamination was determined by swabbing 10 locations, and urine collection was simulated 5 times, using a (1) synthetic urine surrogate and (2) a standardized finger contamination procedure. The most contaminated toilets and bathrooms were in remote Indigenous communities. No contamination was found in the Northern Territory Government Sexual Assault Referral Centre clinics, and intermediate levels of contamination were found in sexual health clinics and in clinics in regional urban centres. The frequency of surrogate urine sample contamination was low but non-zero. For example, 4 of 558 of the urine surrogate specimens from remote clinics were STI positive. This is by far the largest study addressing the potential environmental contamination of urine samples with STI agents. Positive STI tests arising from environmental contamination of urine specimens cannot be ruled out. The results emphasize that urine specimens from young children taken for STI testing should be obtained by trained staff in clean environments, and duplicate specimens should be obtained if possible. © The Author 2013. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society.

  16. Determination of short-lived trace elements in environmental samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Wardani, S.; Sihombing, E.; Hamzah, A.; Rochidi; Hery, P.S.; Hartaman, S.; Iman, J.

    1998-01-01

    Concentration of a short-lived trace elements in environmental samples were determined by neutron activation analysis, a counting loss often occur due to the high counting rate. A Pile-Up Rejecter (PUR) electric circuit was installed in counting a short-lived trace elements by a γ-ray spectrometer in order to correct a counting loss. The samples were irradiated for 30∼60 seconds at neutron flux of 3.5 x 10 12 n.cm -2 .s -1 , then the samples cooled for 120 second and counted for 180 second using this system. The nuclides concentration in the varieties environmental samples have a difference analysis result, was more accurate and precise, which the measured result would be 30 % more higher by PUR system than the result would be counted using a conventional γ-ray spectrometry method

  17. Potential Use of Passive Sampling for Environmental Monitoring of Petroleum E&P Operations

    Science.gov (United States)

    Traditional environmental monitoring relies on water or soil samples being taken at various time increments and sent to offsite laboratories for analysis. Reliance on grab samples generally captures limited “snapshots” of environmental contaminant concentrations, is time intensive, costly, and generates residual waste from excess sample and/or reagents used in the analysis procedures. As an alternative, we are evaluating swellable organosilica sorbents to create passive sampling systems for monitoring applications. Previous work has focused on absorption and detection of fuels, chlorinated solvents, endocrine disruptors, explosives, pesticides, fluorinated chemicals, and metals including Ba, Sr, Hg, Pb, Fe, Cu, and Zn. The advantages of swellable organosilica are that the material cancapture target compounds for an extended periods of time, does not absorb natural organic matter, and resists biofilm formation since the sorbent possesses an animated surface morphology.

  18. Acceptability of self-collection sampling for HPV-DNA testing in low-resource settings: a mixed methods approach.

    Science.gov (United States)

    Bansil, Pooja; Wittet, Scott; Lim, Jeanette L; Winkler, Jennifer L; Paul, Proma; Jeronimo, Jose

    2014-06-12

    Vaginal self-sampling with HPV-DNA tests is a promising primary screening method for cervical cancer. However, women's experiences, concerns and the acceptability of such tests in low-resource settings remain unknown. In India, Nicaragua, and Uganda, a mixed-method design was used to collect data from surveys (N = 3,863), qualitative interviews (N = 72; 20 providers and 52 women) and focus groups (N = 30 women) on women's and providers' experiences with self-sampling, women's opinions of sampling at home, and their future needs. Among surveyed women, 90% provided a self- collected sample. Of these, 75% reported it was easy, although 52% were initially concerned about hurting themselves and 24% were worried about not getting a good sample. Most surveyed women preferred self-sampling (78%). However it was not clear if they responded to the privacy of self-sampling or the convenience of avoiding a pelvic examination, or both. In follow-up interviews, most women reported that they didn't mind self-sampling, but many preferred to have a provider collect the vaginal sample. Most women also preferred clinic-based screening (as opposed to home-based self-sampling), because the sample could be collected by a provider, women could receive treatment if needed, and the clinic was sanitary and provided privacy. Self-sampling acceptability was higher when providers prepared women through education, allowed women to examine the collection brush, and were present during the self-collection process. Among survey respondents, aids that would facilitate self-sampling in the future were: staff help (53%), additional images in the illustrated instructions (31%), and a chance to practice beforehand with a doll/model (26%). Self-and vaginal-sampling are widely acceptable among women in low-resource settings. Providers have a unique opportunity to educate and prepare women for self-sampling and be flexible in accommodating women's preference for self-sampling.

  19. Green Aspects of Techniques for the Determination of Currently Used Pesticides in Environmental Samples

    OpenAIRE

    Maciej Tankiewicz; Jacek Namieśnik; Jolanta Stocka; Marek Biziuk

    2011-01-01

    Pesticides are among the most dangerous environmental pollutants because of their stability, mobility and long-term effects on living organisms. Their presence in the environment is a particular danger. It is therefore crucial to monitor pesticide residues using all available analytical methods. The analysis of environmental samples for the presence of pesticides is very difficult: the processes involved in sample preparation are labor-intensive and time-consuming. To date, it has been standa...

  20. Hanford Site surface environmental surveillance

    International Nuclear Information System (INIS)

    Dirkes, R.L.

    1998-01-01

    Environmental surveillance of the Hanford Site and the surrounding region is conducted to demonstrate compliance with environmental regulations, confirm adherence to US Department of Energy (DOE) environmental protection policies, support DOE environmental management decisions, and provide information to the public. The Surface Environmental Surveillance Project (SESP) is a multimedia environmental monitoring program conducted to measure the concentrations of radionuclides and chemical contaminants in the environment and assess the integrated effects of these contaminants on the environment and the public. The monitoring program includes sampling air, surface water, sediments, soil, natural vegetation, agricultural products, fish, and wildlife. Functional elements inherent in the operation of the SESP include project management, quality assurance/control, training, records management, environmental sampling network design and implementation, sample collection, sample analysis, data management, data review and evaluation, exposure assessment, and reporting. The SESP focuses on those contaminant/media combinations calculated to have the highest potential for contributing to off-site exposure. Results of the SESP indicate that contaminant concentrations in the Hanford environs are very low, generally below environmental standards, at or below analytical detection levels, and indicative of environmental levels. However, areas of elevated contaminant concentrations have been identified at Hanford. The extent of these areas is generally limited to past operating areas and waste disposal sites

  1. Improved analytical sensitivity for uranium and plutonium in environmental samples: Cavity ion source thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Ingeneri, Kristofer; Riciputi, L.

    2001-01-01

    Following successful field trials, environmental sampling has played a central role as a routine part of safeguards inspections since early 1996 to verify declared and to detect undeclared activity. The environmental sampling program has brought a new series of analytical challenges, and driven a need for advances in verification technology. Environmental swipe samples are often extremely low in concentration of analyte (ng level or lower), yet the need to analyze these samples accurately and precisely is vital, particularly for the detection of undeclared nuclear activities. Thermal ionization mass spectrometry (TIMS) is the standard method of determining isotope ratios of uranium and plutonium in the environmental sampling program. TIMS analysis typically employs 1-3 filaments to vaporize and ionize the sample, and the ions are mass separated and analyzed using magnetic sector instruments due to their high mass resolution and high ion transmission. However, the ionization efficiency (the ratio of material present to material actually detected) of uranium using a standard TIMS instrument is low (0.2%), even under the best conditions. Increasing ionization efficiency by even a small amount would have a dramatic impact for safeguards applications, allowing both improvements in analytical precision and a significant decrease in the amount of uranium and plutonium required for analysis, increasing the sensitivity of environmental sampling

  2. Evaluation of oxidation techniques for preparing bioassay and environmental samples for liquid scintillation counting

    International Nuclear Information System (INIS)

    Miller, H.H.

    1979-10-01

    In environmental and biological monitoring for carbon-14 and tritium, the presence of color and chemical quenching agents in the samples can degrade the efficiency of liquid scintillation counting. A series of experiments was performed to evaluate the usefulness, under routine conditions, of first oxidizing the samples to improve the counting by removing the color and quenching agents. The scintillation counter was calibrated for the effects of quenching agents on its counting efficiency. Oxidizing apparatus was tested for its ability to accurately recover the 14 C and 3 H in the samples. Scintillation counting efficiences were compared for a variety of oxidized and unoxidized environmental and bioassay samples. The overall conclusion was that, for routine counting, oxidation of such samples is advantageous when they are highly quenched or in solid form

  3. Comparison of Antemortem and Environmental Samples for Zebrafish Health Monitoring and Quarantine

    Science.gov (United States)

    Crim, Marcus J; Lawrence, Christian; Livingston, Robert S; Rakitin, Andrei; Hurley, Shane J; Riley, Lela K

    2017-01-01

    Molecular diagnostic assays offer both exquisite sensitivity and the ability to test a wide variety of sample types. Various types of environmental sample, such as detritus and concentrated water, might provide a useful adjunct to sentinels in routine zebrafish health monitoring. Similarly, antemortem sampling would be advantageous for expediting zebrafish quarantine, without euthanasia of valuable fish. We evaluated the detection of Mycobacterium chelonae, M. fortuitum, M. peregrinum, Pseudocapillaria tomentosa, and Pseudoloma neurophilia in zebrafish, detritus, pooled feces, and filter membranes after filtration of 1000-, 500-, and 150-mL water samples by real-time PCR analysis. Sensitivity varied according to sample type and pathogen, and environmental sampling was significantly more sensitive than zebrafish sampling for detecting Mycobacterium spp. but not for Pseudocapillaria neurophilia or Pseudoloma tomentosa. The results of these experiments provide strong evidence of the utility of multiple sample types for detecting pathogens according to each pathogen's life cycle and ecological niche within zebrafish systems. In a separate experiment, zebrafish subclinically infected with M. chelonae, M. marinum, Pleistophora hyphessobryconis, Pseudocapillaria tomentosa, or Pseudoloma neurophilia were pair-spawned and individually tested with subsets of embryos from each clutch that received no rinse, a fluidizing rinse, or were surface-disinfected with sodium hypochlorite. Frequently, one or both parents were subclinically infected with pathogen(s) that were not detected in any embryo subset. Therefore, negative results from embryo samples may not reflect the health status of the parent zebrafish. PMID:28724491

  4. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    Science.gov (United States)

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  5. Oak Ridge Reservation Annual Site Environmental Report for 2009

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Sharon D [ORNL; Loffman, Regis S [ORNL

    2010-10-01

    The Oak Ridge Reservation Annual Site Environmental Report is prepared annually and presents summary environmental data to (1) characterize environmental performance, (2) summarize environmental occurrences reported during the year, (3) confirm compliance with environmental standards and requirements, and (4) highlight significant program activities. The report fulfills the requirement contained in DOE Order 231.1A, Environment, Safety and Health Reporting (DOE 2004) that an integrated annual site environmental report be prepared. The results summarized in this report are based on data collected prior to and through 2009. This report is not intended to nor does it present the results of all environmental monitoring associated with the ORR. Data collected for other site and regulatory purposes, such as environmental restoration/remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws and are referenced herein as appropriate. Appendix A to this report identifies corrections for the 2008 report. Appendix B contains a glossary of technical terms that may be useful for understanding the terminology used in this document. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the points of release to the environment; these measurements allow the quantification and official reporting of contaminant levels, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of direct measurements and collection and analysis of samples taken from the site and its environs exclusive of effluents

  6. Oak Ridge Reservation Annual Site Environmental Report for 2010

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Sharon D [ORNL

    2011-10-01

    The Oak Ridge Reservation Annual Site Environmental Report is prepared annually and presents summary environmental data to (1) characterize environmental performance, (2) summarize environmental occurrences reported during the year, (3) confirm compliance with environmental standards and requirements, and (4) highlight significant program activities. The report fulfills the requirement contained in DOE Order 231.1A, Environment, Safety and Health Reporting (DOE 2004) that an integrated annual site environmental report be prepared. The results summarized in this report are based on data collected prior to and through 2010. This report is not intended to nor does it present the results of all environmental monitoring associated with the ORR. Data collected for other site and regulatory purposes, such as environmental restoration/remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws and are referenced herein as appropriate. Appendix A to this report identifies corrections to the 2009 report. Appendix B contains a glossary of technical terms that may be useful for understanding the terminology used in this document. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the points of release to the environment; these measurements allow the quantification and official reporting of contaminant levels, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of direct measurements and collection and analysis of samples taken from the site and its environs exclusive of effluents

  7. Oak Ridge Reservation Annual Site Environmental Report for 2009

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Jacobs

    2010-09-01

    The Oak Ridge Reservation Annual Site Environmental Report is prepared animally and presents summary environmental data to (1) characterize environmental performance, (2) summarize environmental occurrences reported during the year, (3) confirm compliance with environmental standards and requirements, and (4) highlight significant program activities. The report fulfills the requirement contained in DOE Order 231.1 A, Environment, Safety and Health Reporting (DOE 2004) that an integrated annual site environmental report be prepared. The results summarized in this report are based on data collected prior to and through 2009. This report is not intended to nor does it present the results of all environmental monitoring associated with the ORR. Data collected for other site and regulatory purposes, such as environmental restoration/remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws and are referenced herein as appropriate. Appendix A to this report identifies corrections to the 2008 report. Appendix B contains a glossary of technical terms that may be useful for understanding the terminology used in this document. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the points of release to the environment; these measurements allow the quantification and official reporting of contaminant levels, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of direct measurements and collection and analysis of samples taken from the site and its environs exclusive of effluents

  8. [Establishment and Management of Multicentral Collection Bio-sample Banks of Malignant Tumors from Digestive System].

    Science.gov (United States)

    Shen, Si; Shen, Junwei; Zhu, Liang; Wu, Chaoqun; Li, Dongliang; Yu, Hongyu; Qiu, Yuanyuan; Zhou, Yi

    2015-11-01

    To establish and manage of multicentral collection bio-sample banks of malignant tumors from digestive system, the paper designed a multicentral management system, established the standard operation procedures (SOPs) and leaded ten hospitals nationwide to collect tumor samples. The biobank has been established for half a year, and has collected 695 samples from patients with digestive system malignant tumor. The clinical data is full and complete, labeled in a unified way and classified to be managed. The clinical and molecular biology researches were based on the biobank, and obtained achievements. The biobank provides a research platform for malignant tumor of digestive system from different regions and of different types.

  9. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    Science.gov (United States)

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  10. Implementation trial of high performance trace analysis/environmental sampling (HPTA/ES) in uranium centrifuge enrichment plants

    International Nuclear Information System (INIS)

    Nackaerts, H.; Kloeckner, W.; Landresse, G.; MacLean, F.; Betti, M.; Forcina, V.; Hiernaut, T.; Tamborini, G.; Koch, L.; Schenkel, R.

    1999-01-01

    Field trials have demonstrated that the analysis of particles upon swipes obtained from inside nuclear installations provides clear signatures of past operations in that installation. This can offer a valuable tool for gaining assurance regarding the compliance with declared activities and the absence of undeclared activities (e.g. enrichment, reprocessing, and reactor operation) at such sites. This method, known as 'Environmental Sampling' (ES) or 'High Performance Trace Analysis' (HPTA) in EURATOM terminology, is at present being evaluated by the EURATOM Safeguards Directorate (ESD) in order to assess its possible use in nuclear installations within the European Union. It is expected that incorporation of HPTA/ES of sample collection and analysis into routine inspection activities will allow EURATOM to improve the effectiveness of safeguards in these installations and hopefully save inspection resources as well. The EURATOM Safeguards Directorate has therefore performed implementation trials involving the collection of particles by the so-called swipe sampling method in uranium centrifuge enrichment plants and hot cells in the European Union. These samples were subsequently analysed by the Joint Research Centre, Institute for Transuranium Elements (ITU) in Karlsruhe. Sampling points were chosen on the basis of the activities performed in the vicinity and by considering the possible ways through which particles are released, diffused and transported. The aim was to test the efficiency of the method as regards: the collection of enough representative material; the identification of a large enough number of uranium particles; the accurate measurement of the enrichment of the uranium particles found on the swipe; the representativity of the results in respect of past activities in the plant; the capability of detecting whether highly enriched uranium has been produced, used or occasionally transported in a location where low enriched uranium is routinely produced in

  11. Intact preservation of environmental samples by freezing under an alternating magnetic field.

    Science.gov (United States)

    Morono, Yuki; Terada, Takeshi; Yamamoto, Yuhji; Xiao, Nan; Hirose, Takehiro; Sugeno, Masaya; Ohwada, Norio; Inagaki, Fumio

    2015-04-01

    The study of environmental samples requires a preservation system that stabilizes the sample structure, including cells and biomolecules. To address this fundamental issue, we tested the cell alive system (CAS)-freezing technique for subseafloor sediment core samples. In the CAS-freezing technique, an alternating magnetic field is applied during the freezing process to produce vibration of water molecules and achieve a stable, super-cooled liquid phase. Upon further cooling, the temperature decreases further, achieving a uniform freezing of sample with minimal ice crystal formation. In this study, samples were preserved using the CAS and conventional freezing techniques at 4, -20, -80 and -196 (liquid nitrogen) °C. After 6 months of storage, microbial cell counts by conventional freezing significantly decreased (down to 10.7% of initial), whereas that by CAS-freezing resulted in minimal. When Escherichia coli cells were tested under the same freezing conditions and storage for 2.5 months, CAS-frozen E. coli cells showed higher viability than the other conditions. In addition, an alternating magnetic field does not impact on the direction of remanent magnetization in sediment core samples, although slight partial demagnetization in intensity due to freezing was observed. Consequently, our data indicate that the CAS technique is highly useful for the preservation of environmental samples. © 2014 Society for Applied Microbiology and John Wiley & Sons Ltd.

  12. Sample test cases using the environmental computer code NECTAR

    International Nuclear Information System (INIS)

    Ponting, A.C.

    1984-06-01

    This note demonstrates a few of the many different ways in which the environmental computer code NECTAR may be used. Four sample test cases are presented and described to show how NECTAR input data are structured. Edited output is also presented to illustrate the format of the results. Two test cases demonstrate how NECTAR may be used to study radio-isotopes not explicitly included in the code. (U.K.)

  13. Determination of 237Np in environmental and nuclear samples: A review of the analytical method

    International Nuclear Information System (INIS)

    Thakur, P.; Mulholland, G.P.

    2012-01-01

    A number of analytical methods has been developed and used for the determination of neptunium in environmental and nuclear fuel samples using alpha, ICP–MS spectrometry, and other analytical techniques. This review summarizes and discusses development of the radiochemical procedures for separation of neptunium (Np), since the beginning of the nuclear industry, followed by a more detailed discussion on recent trends in the separation of neptunium. This article also highlights the progress in analytical methods and issues associated with the determination of neptunium in environmental samples. - Highlights: ► Determination of Np in environmental and nuclear samples is reviewed. ► Various analytical methods used for the determination of Np are listed. ► Progress and issues associated with the determination of Np are discussed.

  14. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  15. Determination of Kr-85 in environmental samples and gaseous effluents from nuclear industries using the standard method

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    The determination of the Kr-85 activity in environmental samples and gaseous effluents from Spanish Nuclear Power Stations is described. The method employed has been published elsewhere. The determinations has been carried out in environmental samples token at JEN Laboratories (Madrid) and the Nuclear Power Stations, Jose Cabrera (Zorita), Garona and Vandellos. Also samples of gaseous effluents of the three plants has been analyzed. Values of the Kr-85 environmental background activity in the Almaraz Nuclear Power Stations, has been determined, before the beginning of its nuclear activity. In this paper the sampling equipment used is described and the values found of Kr-85 activity in all the samples in given. (Author) 29 refs

  16. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Science.gov (United States)

    2010-01-01

    ... laboratory within one day. If delivery is delayed, samples should be refrigerated. (a) For egg- and meat-type chickens, waterfowl, exhibition poultry, and game birds. All samples and swabs described in this paragraph...

  17. Variability and reliability of POP concentrations in multiple breast milk samples collected from the same mothers.

    Science.gov (United States)

    Kakimoto, Risa; Ichiba, Masayoshi; Matsumoto, Akiko; Nakai, Kunihiko; Tatsuta, Nozomi; Iwai-Shimada, Miyuki; Ishiyama, Momoko; Ryuda, Noriko; Someya, Takashi; Tokumoto, Ieyasu; Ueno, Daisuke

    2018-01-13

    Risk assessment of infant using a realistic persistent organic pollutant (POP) exposure through breast milk is essential to devise future regulation of POPs. However, recent investigations have demonstrated that POP levels in breast milk collected from the same mother showed a wide range of variation daily and monthly. To estimate the appropriate sample size of breast milk from the same mother to obtain reliable POP concentrations, breast milk samples were collected from five mothers living in Japan from 2006 to 2012. Milk samples from each mother were collected 3 to 6 times a day through 3 to 7 days consecutively. Food samples as the duplicated method were collected from two mothers during the period of breast milk sample collection. Those were employed for POP (PCBs, DDTs, chlordanes, and HCB) analysis. PCB concentrations detected in breast milk samples showed a wide range of variation which was maximum 63 and 60% of relative standard deviation (RSD) in lipid and wet weight basis, respectively. The time course trend of those variations among the mothers did not show any typical pattern. A larger amount of PCB intake through food seemed to affect 10 h after those concentrations in breast milk in lipid weight basis. Intraclass correlation coefficient (ICC) analyses indicated that the appropriate sample size for good reproducibility of POP concentrations in breast milk required at least two samples for lipid and wet weight basis.

  18. Environmental assessment of wood industrial and collective (with heat network) heating. Synthetic report

    International Nuclear Information System (INIS)

    2005-12-01

    This report proposes a synthesis of the results of an environmental assessment of wood industrial and collective heating. This study is based on a life cycle analysis which quantifies the impacts on the environment of all the related activities: fuel extraction, retailing, final use, and so on. Environmental impacts are assessed by means of different indicators: energetic assessment, greenhouse effect assessment, air pollution (acidification), water pollution (eutrophication), toxic material emissions in air and into the soils. Wood is compared to other heating sources (gas, fuel, electricity). Ways to improve this environmental assessment are discussed with respect to wood supply, boiler auxiliary equipment, boiler and combustion

  19. Concentration and speciation of radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Testa, C.; Desideri, D.; Meli, M.A.; Roselli, C.

    2000-01-01

    The paper will describe three examples dealing with the measure of some natural (U, Th, 2 10Pb, 4 0K) and artificial ( 1 37Cs, 9 0Sr, 2 39 +2 40Pu, 2 41Am) radionuclides in environmental samples such as mosses, sediments, soils. Extraction chromatography, liquid extraction, selective precipitation and electroplating were used to isolate the radionuclides, except for gamma emitters which were detected by gamma spectrometry. Alpha spectrometry were used to measure the alpha emitters and low background beta detector to measure the beta emitters

  20. Legacy sample disposition project. Volume 2: Final report

    International Nuclear Information System (INIS)

    Gurley, R.N.; Shifty, K.L.

    1998-02-01

    This report describes the legacy sample disposition project at the Idaho Engineering and Environmental Laboratory (INEEL), which assessed Site-wide facilities/areas to locate legacy samples and owner organizations and then characterized and dispositioned these samples. This project resulted from an Idaho Department of Environmental Quality inspection of selected areas of the INEEL in January 1996, which identified some samples at the Test Reactor Area and Idaho Chemical Processing Plant that had not been characterized and dispositioned according to Resource Conservation and Recovery Act (RCRA) requirements. The objective of the project was to manage legacy samples in accordance with all applicable environmental and safety requirements. A systems engineering approach was used throughout the project, which included collecting the legacy sample information and developing a system for amending and retrieving the information. All legacy samples were dispositioned by the end of 1997. Closure of the legacy sample issue was achieved through these actions

  1. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    Science.gov (United States)

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  2. Middlesex Sampling Plant annual environmental report for calendar year 1991, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    1992-09-01

    This document describes the environmental monitoring program at the-Middlesex Sampling Plant (MSP) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring of MSP began in 1980 when Congress added the site to the US Department of Energy's (DOE) Formerly Utilized Sites Remedial Action Program (FUSRAP). FUSRAP is a DOE program to decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program at MSP includes sampling networks for radon and thoron concentrations in air; external gamma radiation exposure; and radium-226, thorium-232, and total uranium concentrations in surface water, sediment,, and groundwater. Additionally, several nonradiological parameters are measured in groundwater, surface water, and sediment. Results of environmental monitoring during 1991 indicate that most concentrations were well below applicable guidelines. The potential radiation dose calculated for a hypothetical maximally exposed individual, based on a conservative but realistic exposure scenario, is 2.3 mrem (milliroentgen equivalent man) per year, which is less than an individual would receive while traveling in an airplane at 12,000 meters for five hours. During 1991, there were no nonroutine releases from the site; MSP was in compliance with applicable regulations for releases from the site. Site activities included environmental monitoring, site maintenance, onsite characterization for the MSP remedial investigation, and additional sediment sampling at the plant outfall to determine the source of the elevated levels of radium-226 and thorium-232

  3. Insular Biobjective Routing with Environmental Considerations for a Solid Waste Collection System in Southern Chile

    Directory of Open Access Journals (Sweden)

    Daniela S. Arango González

    2017-01-01

    Full Text Available This paper presents a biobjective problem for a solid waste collection system in a set of islands in southern Chile. The first objective minimizes transportation cost and the second one reduces the environmental impact caused by the accumulation of solid waste at the collection points. To solve this problem, biobjective mixed integer linear programming is used. In the model, an itinerary scheme is considered for the visit to the islands. The model decides which collection points are visited per island, the collection pattern, and quantity of solid waste to be collected at each site. The quantity of solid waste is obtained dividing the solid waste generated in the island by the number of collection points selected in that same island and the frequency of visits. For this problem, we considered that the environmental impact function varies through the days during which solid waste is accumulated at each collection point. We present an instance based on real data for a set of islands in Chiloe and Palena regions in southern Chile, in which the deposit node is Dalcahue. We used the epsilon-constraint method and the weighted sum method to obtain the Pareto front, using commercial optimization software.

  4. A review of analytical techniques for the determination of carbon-14 in environmental samples

    International Nuclear Information System (INIS)

    Milton, G.M.; Brown, R.M.

    1993-11-01

    This report contains a brief summary of analytical techniques commonly used for the determination of radiocarbon in a variety of environmental samples. Details of the applicable procedures developed and tested in the Environmental Research Branch at Chalk River Laboratories are appended

  5. Water Sample Points, Navajo Nation, 2000, USACE

    Data.gov (United States)

    U.S. Environmental Protection Agency — This point shapefile presents the locations and results for water samples collected on the Navajo Nation by the US Army Corps of Engineers (USACE) for the US...

  6. Engineering Task Plan to Expand the Environmental Operational Envelope of Core Sampling

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This Engineering Task Plan authorizes the development of an Alternative Generation and Analysis (AGA). The AGA will determine how to expand the environmental operating envelope during core sampling operations

  7. Determination of 241Am and 244Cm in environmental samples

    International Nuclear Information System (INIS)

    Bonino, N.O.; Grinman, A.D.R.; Serdeiro, N.H.

    1998-01-01

    The present technique describes a method to separate, purify and measure low levels of americium and curium in different environmental samples such as sediments, soils, water, vegetables, and air filters. The determination of radionuclides in theses environmental matrices have analytical problems, since a simple method doesn't exist for the purification, which is indispensable for its later measuring alpha spectrometry. The developed technique consist on taking an aliquot of the sample to analyze, to add tracer as americium 243 and curium 242, and to dissolve the matrix in a such way to have a clear solution. For the isolation of the americium and curium of the other actinides ar used as separation techniques: precipitation with Fe 3+ , anionic and cationic exchange, and extraction with a appropriate organic solvent. The purification of the americium and curium is followed by the electrodeposition habitually used. The measurement is carried out by alpha spectrometry with a detector of implanted ion. The detection limit for this techniques is of 0,002 Bq/l or 0,2 mBq in the case of filters. (author)

  8. A simple passive method of collecting water vapour for environmental tritium monitoring

    International Nuclear Information System (INIS)

    Iida, T.; Fukuda, H.; Ikebe, Y.; Yokoyama, S.

    1995-01-01

    To investigate the average behaviour of tritium in an atmospheric environment, it is necessary to collect water vapour in air over a long period at numerous locations. For the purpose of the study, the passive method was developed: this is handy, low-priced and could collect water vapour in air without motive power. This paper describes the characteristics of the passive collecting method, the performance of water collection in outdoor air and the measurements of tritium concentrations in water samples collected by the passive method. (author)

  9. A software for radioactivity measurement of Ra, Th and K in environmental samples

    International Nuclear Information System (INIS)

    Miao Zhengqiang; Bao Min; Chang Yongfu

    2004-01-01

    Radio nuclides of soil, rock, construction material, and almost everything around us. There is growing concern about environmental radioactivity from both scientists and public from an institutional or a common point of view. The regulation and standard on evaluating radioactivity of environmental samples have been issued recently by the authorities. We have developed special purpose Gamma spectra analysis software named ErSpec. The software can effectively process and analyze Gamma spectra measured by a NaI(T1) spectrometry, and can give a relatively precise results of radioactivity of 226 Ra, 232 Th and 40 K in environmental samples. The main functions of ErSpec include, processing and analyzing Gamma spectra, displaying some useful information for users, generating report, managing user's priority, logging user's manipulation, etc. Because environmental samples usually have low radioactivity and have complex measurement conditions, relative method is employed in ErSpec, and Channel-by-Channel Least-Squared Estimation is adopted as spectra analyzing method. The arithmetic make use of information extracted from data of hundreds of channels, then give a rather good result. In ErSpec, by using external call of MatLAB Math Lib in Visual C++, accuracy and speed of calculation and robustness of software are improved distinctly. Object-Oriented Programming Method and ActiveX techniques are also employed in software designing and coding stage. (authors)

  10. Contamination of the air and other environmental samples of the Ulm region by radioactive fission products after the accident of the Chernobyl reactor

    International Nuclear Information System (INIS)

    Krivan, V.; Egger, K.P.; Hausbeck, R.; Schmid, W.

    1986-01-01

    Since April 30, 1986, the radioactivity of the fission products released by the accident of the Chernobyl reactor has been measured in the air of the city of Ulm. The airborne dust samples were collected with flow calibrated samplers on cellulose acetate membrane filters and counted with a high resolution gamma ray spectrometer. Later on, the radioactivity measurements were expanded to other relevant environmental samples contaminated by radioactive atmospheric precipitates including grass, spruce needles, mosses, lichens, various kinds of food, drinking water, asphalt and concrete surface layers, municipal sewage sludge and sewage sludge ash. This paper reports the obtained results. (orig.) [de

  11. Dynamic Flow-through Methods for Metal Fractionation in Environmental Solid Samples

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald; Petersen, Roongrat

    occurring processes always take place under dynamic conditions, recent trends have been focused on the development of alternative flow-through dynamic methods aimed at mimicking environmental events more correctly than their classical extraction counterparts. In this lecture particular emphasis is paid......Accummulation of metal ions in different compartments of the biosphere and their possible mobilization under changing environmental conditions induce a pertubation of the ecosystem and may cause adverse health effects. Nowadays, it is widely recognized that the information on total content...... the ecotoxicological significance of metal ions in solid environmental samples. The background of end-over-end fractionation for releasing metal species bound to particular soil phases is initially discussed, its relevant features and limitations being thoroughly described. However, taking into account that naturally...

  12. Validation of Marek's disease diagnosis and monitoring of Marek's disease vaccines from samples collected in FTA cards.

    Science.gov (United States)

    Cortes, Aneg L; Montiel, Enrique R; Gimeno, Isabel M

    2009-12-01

    The use of Flinders Technology Associates (FTA) filter cards to quantify Marek's disease virus (MDV) DNA for the diagnosis of Marek's disease (MD) and to monitor MD vaccines was evaluated. Samples of blood (43), solid tumors (14), and feather pulp (FP; 36) collected fresh and in FTA cards were analyzed. MDV DNA load was quantified by real-time PCR. Threshold cycle (Ct) ratios were calculated for each sample by dividing the Ct value of the internal control gene (glyceraldehyde-3-phosphate dehydrogenase) by the Ct value of the MDV gene. Statistically significant correlation (P FTA cards by using Pearson's correlation test. Load of serotype 1 MDV DNA was quantified in 24 FP, 14 solid tumor, and 43 blood samples. There was a statistically significant correlation between FP (r = 0.95), solid tumor (r = 0.94), and blood (r = 0.9) samples collected fresh and in FTA cards. Load of serotype 2 MDV DNA was quantified in 17 FP samples, and the correlation between samples collected fresh and in FTA cards was also statistically significant (Pearson's coefficient, r = 0.96); load of serotype 3 MDV DNA was quantified in 36 FP samples, and correlation between samples taken fresh and in FTA cards was also statistically significant (r = 0.84). MDV DNA samples extracted 3 days (t0) and 8 months after collection (t1) were used to evaluate the stability of MDV DNA in archived samples collected in FTA cards. A statistically significant correlation was found for serotype 1 (r = 0.96), serotype 2 (r = 1), and serotype 3 (r = 0.9). The results show that FTA cards are an excellent media to collect, transport, and archive samples for MD diagnosis and to monitor MD vaccines. In addition, FTA cards are widely available, inexpensive, and adequate for the shipment of samples nationally and internationally.

  13. Methods for simultaneous detection of the cyanotoxins BMAA, DABA, and anatoxin-a in environmental samples.

    Science.gov (United States)

    Al-Sammak, Maitham Ahmed; Hoagland, Kyle D; Snow, Daniel D; Cassada, David

    2013-12-15

    Blue-green algae, also known as cyanobacteria, can produce several different groups of toxins in the environment including hepatotoxins (microcystins), neurotoxic non-protein amino acids β-methylamino-l-alanine (BMAA), and 2,4-diaminobutyric (DABA), as well as the bicyclic amine alkaloid anatoxin-a. Few studies have addressed the methods necessary for an accurate determination of cyanotoxins in environmental samples, and none have been published that can detect these cyanotoxins together in a single sample. Cyanotoxins occur in a wide range of environmental samples including water, fish, and aquatic plant samples. Using polymeric cation exchange solid phase extraction (SPE) coupled with liquid chromatography and fluorescence detection (HPLC/FD), and liquid chromatography ion trap tandem mass spectrometry (LC/MS/MS), these compounds can for the first time be simultaneously quantified in a variety of environmental sample types. The extraction method for biological samples can distinguish bound and free cyanotoxins. Detection limits for water ranged from 5 to 7 μg/L using HPLC/FD, while detection limits for and LC/MS were in the range of 0.8-3.2 μg/L. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Directional dependency of air sampling

    International Nuclear Information System (INIS)

    1994-01-01

    A field study was performed by Idaho State University-Environmental Monitoring Laboratory (EML) to examine the directional dependency of low-volume air samplers. A typical continuous low volume air sampler contains a sample head that is mounted on the sampler housing either horizontally through one of four walls or vertically on an exterior wall 'looking down or up.' In 1992, a field study was undertaken to estimate sampling error and to detect the directional effect of sampler head orientation. Approximately 1/2 mile downwind from a phosphate plant (continuous source of alpha activity), four samplers were positioned in identical orientation alongside one sampler configured with the sample head 'looking down'. At least five consecutive weekly samples were collected. The alpha activity, beta activity, and the Be-7 activity collected on the particulate filter were analyzed to determine sampling error. Four sample heads were than oriented to the four different horizontal directions. Samples were collected for at least five weeks. Analysis of the alpha data can show the effect of sampler orientation to a know near source term. Analysis of the beta and Be-7 activity shows the effect of sampler orientation to a ubiquitous source term

  15. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    Energy Technology Data Exchange (ETDEWEB)

    Riscassi, Ami L [ORNL; Miller, Carrie L [ORNL; Brooks, Scott C [ORNL

    2014-01-01

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically we investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.

  16. 78 FR 79009 - Proposed Information Collection; Radiation Sampling and Exposure Records (Pertains to Underground...

    Science.gov (United States)

    2013-12-27

    ... soliciting comments concerning the proposed information collection for updating Radiation Sampling and... exposed with no adverse effects have been established and are expressed as working levels (WL). The... mandatory samplings. Records must include the sample date, location, and results, and must be retained at...

  17. Comparison of semen parameters in samples collected by masturbation at a clinic and at home.

    Science.gov (United States)

    Elzanaty, Saad; Malm, Johan

    2008-06-01

    To investigate differences in semen quality between samples collected by masturbation at a clinic and at home. Cross-sectional study. Fertility center. Three hundred seventy-nine men assessed for infertility. None. Semen was analyzed according to World Health Organization guidelines. Seminal markers of epididymal (neutral alpha-glucosidase), prostatic (prostate-specific antigen and zinc), and seminal vesicle (fructose) function were measured. Two patient groups were defined according to sample collection location: at a clinic (n = 273) or at home (n = 106). Compared with clinic-collected semen, home-collected samples had statistically significantly higher values for sperm concentration, total sperm count, rapid progressive motility, and total count of progressive motility. Semen volume, proportion of normal sperm morphology, neutral alpha-glucosidase, prostate-specific antigen, zinc, and fructose did not differ significantly between groups. An abnormal sperm concentration (masturbation at home compared with at a clinic. This should be taken into consideration in infertility investigations.

  18. An improved combustion apparatus for the determination of organically bound tritium in environmental samples

    International Nuclear Information System (INIS)

    Du, Lin; Shan, Jian; Ma, Yu-Hua; Wang, Ling; Qin, Lai-Lai; Pi, Li; Zeng, You-Shi; Xia, Zheng-Hai; Wang, Guang-Hua; Liu, Wei

    2016-01-01

    This paper reports an improved combustion apparatus for the determination of organically bound tritium in environmental samples. The performance of this apparatus including the recovery rate and reproducibility was investigated by combusting lettuce and pork samples. To determine the factors for the different recovery rates of lettuce and pork and investigate whether the samples were completely oxidized, the ashes and exhaust gases produced by the combustion were analyzed. The results indicate that the apparatus showed an excellent performance in the combustion of environmental samples. Thus, the improvements conducted in this study were effective. - Highlights: • Three major improvements were made to develop the combustion apparatus for OBT. • The recovery is higher and more stable than that of current equipment. • Little hydrogen was present in the ashes and exhaust after combustion.

  19. Environmental surveillance at Hanford for CY 1977

    International Nuclear Information System (INIS)

    Houston, J.R.; Blumer, P.J.

    1978-04-01

    Environmental data collected during 1977 show continued compliance by Hanford with all applicable state and federal regulations. Data were collected for most environmental media including air, Columbia River water, external radiation, foodstuffs (milk, beef, eggs, poultry, and produce) and wildlife (deer, fish, game birds, and oysters from Willapa Bay), as well as soil and vegetation samples. In general, offsite levels of radionuclides attributable to Hanford operations during 1977 were indistinguishable from background levels

  20. Experience with modern technologies at collection, archiving and presentation of environmental data

    International Nuclear Information System (INIS)

    Bartok, J.

    2005-01-01

    This presentation contains solutions in the areas of collection, archiving and presentation of environmental data realised by the company MicroStep-MIS in the Slovakia and abroad. In the first part are characterised in brief used technologies. The second part contains some examples of application of these technologies in complexes monitoring networks

  1. 1998 Environmental Monitoring Program Report for the Idaho National Engineering and Environmental Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    L. V. Street

    1999-09-01

    This report describes the calendar year 1998 compliance monitoring and environmental surveillance activities of the Lockheed Martin Idaho Technologies Company Environmental Monitoring Program performed at the Idaho National Engineering and Environmental Laboratory. This report includes results of sampling performed by the Drinking Water, Effluent, Storm Water, Groundwater Monitoring, and Environmental Surveillance Programs. This report compares the 1998 results to program-specific regulatory guidelines and past data to evaluate trends. The primary purposes of the monitoring and surveillance activities are to evaluate environmental conditions, to provide and interpret data, to verify compliance with applicable regulations or standards, and to ensure protection of public health and the environment. Surveillance of environmental media did not identify any previously unknown environmental problems or trends, which would indicate a loss of control or unplanned releases from facility operations. The INEEL complied with permits and applicable regulations, with the exception of nitrogen samples in a disposal pond effluent stream and iron and total coliform bacteria in groundwater downgradient from one disposal pond. Data collected by the Environmental Monitoring Program demonstrate that the public health and environment were protected.

  2. Correlation between some environmental variables and abundance ...

    African Journals Online (AJOL)

    Correlation between some environmental variables and abundance of Almophrya mediovacuolata (Ciliophora: Anoplophryidae) endocommensal ciliate of an ... The survey primarily involved soil samples collection from the same spots of EW collection and preparation for physico-chemical analysis; evaluation in situ of the ...

  3. Effect of Environmental and Behavioral Interventions on Pain Intensity in Preterm Infants for Heel Prick Blood Sampling in the Neonatal Intensive Care Unit.

    Science.gov (United States)

    Baharlooei, Fatemeh; Marofi, Maryam; Abdeyazdan, Zahra

    2017-01-01

    Recent researches suggest that preterm infants understand pain and stress. Because of the wide range of effects of pain on infants, the present study was conducted on the effect of environmental and behavioral interventions on pain due to heel-prick blood sampling in preterm infants. A clinical trial was conducted among 32 infants with gestational age of 32-37 weeks in the intervention and control groups. The effects of noise reduction by earplugs, light reduction by blindfolds, reduction of nursing manipulation, and creation of intrauterine position for neonates, 30 minutes before taking blood samples until 30 minutes after it, were measured during the intervention stage. Data were collected using the Neonatal Infant Pain Scale (NIPS) in 5 stages (before intervention, 2 minutes before sampling, during the sampling, and 5 minutes and 30 minutes after the sampling). The data were analyzed using analysis of variance (ANOVA) and paired t -test in SPSS software. The paired t -test results showed no significant differences between the control and intervention stages in terms of pain scores at base time ( P = 0.42) and 2 minutes before sampling ( P = 0.12). However, at the sampling time ( P = 0.0), and 5 minutes ( P = 0.001) and 30 minutes after the sampling ( P = 0.001), mean pain score in the intervention stage was significantly less than that in the control stage. Based on the findings, environmental and behavioral interventions reduced pain and facilitated heel-prick blood sampling in preterm infants.

  4. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    Science.gov (United States)

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged 18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  5. Radiochemical separation of actinides for their determination in environmental samples and waste products

    Energy Technology Data Exchange (ETDEWEB)

    Gleisberg, B [Nuclear Engineering and Analytics Rossendorf, Inc. (VKTA), Dresden (Germany)

    1997-03-01

    The determination of low level activities of actinides in environmental samples and waste products makes high demands on radiochemical separation methods. Artificial and natural actinides were analyzed in samples form the surrounding areas of NPP and of uranium mines, incorporation samples, solutions containing radioactive fuel, solutions and solids resutling from the process, and in wastes. The activities are measured by {alpha}-spectrometry and {gamma}-spectrometry. (DG)

  6. Direct separation of plutonium by thermochromatography from environmental samples

    International Nuclear Information System (INIS)

    Wacker, L.; Kraehenbuehl, U.

    2002-01-01

    A thermochromatographic separation was performed on plutonium from environmental soil samples. This procedure was investigated with the goal to measure low concentrations of plutonium by inductively coupled plasma-mass spectrometry (ICP-MS). The soil sample was chlorinated by thionylchloride as reactive gas at a temperature of 1400 K. The volatile chlorides were separated chromatographically and deposited in a temperature gradient tube filled with quartz grains. Results about the deposition behaviour of the elements were obtained. Two different formalisms based on the thermodynamic functions are used to describe the experimental data. One formula is used to describe the deposition behaviour of microscopic amounts of plutonium (adsorption), the other formula for macroamounts of the main matrix elements (desublimation). The calculated values are in a reasonable agreement with the experimental data. A determination of plutonium content was successfully made for a referenced sea sediment (IAEA-135) after the thermochromatographic sample preparation for ICP-MS. (orig.)

  7. Sampling and monitoring for the mine life cycle

    Science.gov (United States)

    McLemore, Virginia T.; Smith, Kathleen S.; Russell, Carol C.

    2014-01-01

    Sampling and Monitoring for the Mine Life Cycle provides an overview of sampling for environmental purposes and monitoring of environmentally relevant variables at mining sites. It focuses on environmental sampling and monitoring of surface water, and also considers groundwater, process water streams, rock, soil, and other media including air and biological organisms. The handbook includes an appendix of technical summaries written by subject-matter experts that describe field measurements, collection methods, and analytical techniques and procedures relevant to environmental sampling and monitoring.The sixth of a series of handbooks on technologies for management of metal mine and metallurgical process drainage, this handbook supplements and enhances current literature and provides an awareness of the critical components and complexities involved in environmental sampling and monitoring at the mine site. It differs from most information sources by providing an approach to address all types of mining influenced water and other sampling media throughout the mine life cycle.Sampling and Monitoring for the Mine Life Cycle is organized into a main text and six appendices that are an integral part of the handbook. Sidebars and illustrations are included to provide additional detail about important concepts, to present examples and brief case studies, and to suggest resources for further information. Extensive references are included.

  8. Quest to identify geochemical risk factors associated with chronic kidney disease of unknown etiology (CKDu) in an endemic region of Sri Lanka-a multimedia laboratory analysis of biological, food, and environmental samples.

    Science.gov (United States)

    Levine, Keith E; Redmon, Jennifer Hoponick; Elledge, Myles F; Wanigasuriya, Kamani P; Smith, Kristin; Munoz, Breda; Waduge, Vajira A; Periris-John, Roshini J; Sathiakumar, Nalini; Harrington, James M; Womack, Donna S; Wickremasinghe, Rajitha

    2016-10-01

    The emergence of a new form of chronic kidney disease of unknown etiology (CKDu) in Sri Lanka's North Central Province (NCP) has become a catastrophic health crisis. CKDu is characterized as slowly progressing, irreversible, and asymptomatic until late stages and, importantly, not attributed to diabetes, hypertension, or other known risk factors. It is postulated that the etiology of CKDu is multifactorial, involving genetic predisposition, nutritional and dehydration status, exposure to one or more environmental nephrotoxins, and lifestyle factors. The objective of this limited geochemical laboratory analysis was to determine the concentration of a suite of heavy metals and trace element nutrients in biological samples (human whole blood and hair) and environmental samples (drinking water, rice, soil, and freshwater fish) collected from two towns within the endemic NCP region in 2012 and 2013. This broad panel, metallomics/mineralomics approach was used to shed light on potential geochemical risk factors associated with CKDu. Based on prior literature documentation of potential nephrotoxins that may play a role in the genesis and progression of CKDu, heavy metals and fluoride were selected for analysis. The geochemical concentrations in biological and environmental media areas were quantified. Basic statistical measurements were subsequently used to compare media against applicable benchmark values, such as US soil screening levels. Cadmium, lead, and mercury were detected at concentrations exceeding US reference values in many of the biological samples, suggesting that study participants are subjected to chronic, low-level exposure to these elements. Within the limited number of environmental media samples, arsenic was determined to exceed initial risk screening and background concentration values in soil, while data collected from drinking water samples reflected the unique hydrogeochemistry of the region, including the prevalence of hard or very hard water, and

  9. Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-01

    In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Brite TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.

  10. Collection and preparation of marine samples for radionuclide analysis

    International Nuclear Information System (INIS)

    Holm, E.

    1997-01-01

    The ultimate goal of research in radioecology is to be able to predict the pathways of radioactive material in the environment and hence estimate possible doses to the population in various regions. Knowledge of levels of contamination are necessary to maintain control of operations of nuclear facilities. Correct methods of sample collection, handling and preparation are among the most important parts for a correct assessment. On basis of the final results of radionuclide concentrations, scientific, medical and political decisions are taken. (author)

  11. Using Environmental Variables for Studying of the Quality of Sampling in Soil Mapping

    Directory of Open Access Journals (Sweden)

    A. Jafari

    2016-02-01

    profiles, which were then described, sampled, analyzed and classified according to the USDA soil classification system (16. The basic rationale is to set up a hypercube, the axes of which are the quantiles of rasters of environmental covariates, e.g., digital elevation model. Sampling evaluation was made using the HELS algorithm. This algorithm was written based on the study of Carre et al., 2007 (3 and run in R. Results and Discussion: The covariate dataset is represented by elevation, slope and wetness index (Table 2. All data layers were interpolated to a common grid of 30 m resolution. The size of the raster layer is 421 by 711 grid cells. Each of the three covariates is divided into four quantiles (Table 2. The hypercube character space has 43, i.e. 64 strata (Figure 5. The average number of grid cells within each stratum is therefore 4677 grid cells. The map of the covariate index (Figure 6 shows some patterns representative of the covariate variability. The values of the covariate index range between 0.0045 and 5.95. This means that some strata are very dense compared to others. This index allows us to explain if high or low relative weight of the sampling units (see below is due to soil sampling or covariate density. The strata with the highest density are in the areas with high geomorphology diversity. It means that geomorphology processes can cause the diversity and variability and it is in line with the geomorphology map (Figure 2. Of the 64 strata, 30.4% represent under-sampling, 60.2% represent adequate sampling and 9.4% represent over-sampling. Regarding the covariate index, most of the under-sampling appears in the high covariate index, where soil covariates are then highly variable. Actually, it is difficult to collect field samples in these highly variable areas (Figure 7. Also, most of the over-sampling was observed in areas with alow covariate index (Figure 7. We calculated the weights of all the sampling units and showed the results in Figure 8. One 64

  12. Environmental colonization and onward clonal transmission of carbapenem-resistant Acinetobacter baumannii (CRAB) in a medical intensive care unit: the case for environmental hygiene.

    Science.gov (United States)

    Ng, Deborah H L; Marimuthu, Kalisvar; Lee, Jia Jun; Khong, Wei Xin; Ng, Oon Tek; Zhang, Wei; Poh, Bee Fong; Rao, Pooja; Raj, Maya Devi Rajinder; Ang, Brenda; De, Partha Pratim

    2018-01-01

    In May 2015, we noticed an increase in carbapenem-resistant Acinetobacter baumannii (CRAB) infections in the Medical Intensive Care Unit (MICU). To investigate this, we studied the extent of environmental contamination and subsequent onward clonal transmission of CRAB. We conducted a one-day point prevalence screening (PPS) of the patients and environment in the MICU. We screened patients using endotracheal tube aspirates and swabs from nares, axillae, groin, rectum, wounds, and exit sites of drains. We collected environmental samples from patients' rooms and environment outside the patients' rooms. CRAB isolates from the PPS and clinical samples over the subsequent one month were studied for genetic relatedness by whole genome sequencing (WGS). We collected 34 samples from seven patients and 244 samples from the environment. On the day of PPS, we identified 8 CRAB carriers: 3 who screened positive and 5 previously known clinical infections. We detected environmental contamination in nearly two-thirds of the rooms housing patients with CRAB. WGS demonstrated genetic clustering of isolates within rooms but not across rooms. We analysed 4 CRAB isolates from clinical samples following the PPS. One genetically-related CRAB was identified in the respiratory sample of a patient with nosocomial pneumonia, who was admitted to the MICU five days after the PPS. The extensive environmental colonization of CRAB by patients highlights the importance of environmental hygiene. The transmission dynamics of CRAB needs further investigation.

  13. A simple and novel method for retrieval of Pasteurellaceae from swab samples collected in the field

    DEFF Research Database (Denmark)

    Hansen, Mie J; Bertelsen, Mads F; Dietz, Rune

    2013-01-01

    and stored at -20°C. As a control study, 15 samples were collected from the oral cavity of a captive brown bear. One was immediately plated, while the remaining 12 swabs were stored at -20°C for 7 days and multiples of 30 days up to 330 days prior to plating. Two samples were stored without the medium for 7......Traditionally it has been difficult or impossible to collect and preserve bacterial samples of especially fastidious bacteria in mixed primary cultures, unless the samples could be transported to a laboratory within approximately 24 h. Therefore, a simple novel method for preserving swab samples...... until bacterial isolation can be completed in the laboratory was developed and evaluated. Pasteurellaceae bacteria were used as a representative for fastidious bacteria. A 7.5% glucose serum medium was used as freeze medium. Swab samples were soaked in the medium a maximum of 2 h after collection...

  14. Revisiting the environmental Kuznets curve and pollution haven hypotheses: MIKTA sample.

    Science.gov (United States)

    Bakirtas, Ibrahim; Cetin, Mumin Atalay

    2017-08-01

    This study aims to examine the validity of the environmental Kuznets curve (EKC) and pollution haven hypotheses in Mexico, Indonesia, South Korea, Turkey, and Australia (MIKTA) countries from 1982 to 2011 by using a panel vector auto regressive (PVAR) model. Empirical findings imply that the EKC hypothesis is rejected by the MIKTA sample. However, PVAR estimations reveal Granger causality from income level, foreign direct investment (FDI) inward, and energy consumption to CO 2 emissions. Orthogonalized impulse-response functions are derived from PVAR estimations. According to the analysis results, the response of CO 2 emissions to a shock on FDI is positive. These results assert that FDI has a detrimental effect on environmental quality in MIKTA countries which means the pollution haven hypothesis is confirmed by the MIKTA sample. Therefore, MIKTA countries should revise their current economic growth plans to provide sustainable development and also re-organize their legal infrastructure to induce usage of renewable energy sources.

  15. Some analytical aspects about determination of Sr89 and Sr90 in environmental samples

    International Nuclear Information System (INIS)

    Gasco, C.; Alvarez Garcia, A.

    1988-01-01

    Some problems about determination of Sr 89 and Sr 90 in environmental samples have been studied. The main difficulties are due to the wide range in the concentration of their components and the contents of chemical and radiochemical interferent elements. The behaviour of strontium on ion exchange resin has been described by some experiments in various media: aqueous media, calcium concentration and matrix variable. The differences of alkaline-earth nitrate and carbonate solubilities have been analyzed in nitric acid. The chemical recovery in environmental samples has been determined. (Author)

  16. Procedures for the collection and preservation of groundwater and surface water samples and for the installation of monitoring wells

    International Nuclear Information System (INIS)

    Korte, N.; Kearl, P.

    1984-01-01

    Proper sampling procedures are essential for a successful water-quality monitoring program. It must be emphasized, however, that it is impossible to maintain absolutely in-situ conditions when collecting and preserving a water sample, whether from a flowing stream or an aquifer. Consequently, the most that can reasonably be expected is to collect a best possible sample with minimal disturbance. This document describes procedures for installing monitoring wells and for collecting samples of surface water and groundwater. The discussion of monitoring wells includes mention of multilevel sampling and a general overview of vadose-zone monitoring. Guidelines for well installation are presented in detail. The discussion of water-sample collection contains evaluations of sampling pumps, filtration equipment, and sample containers. Sample-preservation techniques, as published by several government and private sources, are reviewed. Finally, step-by-step procedures for collection of water samples are provided; these procedures address such considerations as necessary equipment, field operations, and written documentation. Separate procedures are also included for the collection of samples for determination of sulfide and for reactive aluminum. The report concludes with a brief discussion of adverse sampling, conditions that may significantly affect the quality of the data. Appendix A presents a rationale for the development and use of statistical considerations in water sampling to ensure a more complete water quality monitoring program. 51 references, 9 figures, 4 tables

  17. Multi-element composition of historical lichen collections and bark samples, indicators of changing atmospheric conditions

    Science.gov (United States)

    Purvis, O. W.; Chimonides, P. D. J.; Jeffries, T. E.; Jones, G. C.; Rusu, A.-M.; Read, H.

    Thirty six element signatures were compared in historical Parmelia sulcata samples from the Natural History Museum herbarium collected over the period 1797-1967 with those recorded in the same species and tree bark sampled in 2000 from Burnham Beeches, lying 40 km west of London. Nineteen elements reached highest concentrations in herbarium samples, consistent with a pollution legacy and dust contamination in the herbarium. Healthy Parmelia sampled east and down-wind of London at a farm during peak SO 2 emissions in 1967 contained highest V, Ni, Zn, Cd, Se, Ge contents, supporting derivation from fuel combustion; the same sample was previously determined as having a low δ34S and high S and N contents. Lowest V, Co, Ni, Cu, Zn, Sn, Ba, Pb, Mo, Sb, Li, B, Cs, U, Th, Ga contents were recorded in a sample with a high δ34S and low S content collected in 1887 from a remote region from Ross-shire, Scotland. Se and Cd enrichment, never-the-less suggest a transboundary pollution influence. Lichen Pb concentrations from Burnham Beeches were amongst the lowest recorded in spite of lichens being collected close to roads. Herbarium samples help interpret changes in element deposition where few data exist, in spite of dust contamination.

  18. Total reflection X-ray fluorescence with synchrotron radiation applied to biological and environmental samples

    International Nuclear Information System (INIS)

    Simabuco, S.M.; Matsumoto, E.; Jesus, E.F.O.; Lopes, R.T.; Perez, C.; Nascimento Filho, V.F.; Costa, R.S.S.; Tavares do Carmo, M.G.; Saunders, C.

    2001-01-01

    Full text: The Total Reflection X-ray Fluorescence has been applied for trace elements in water and aqueous solutions, environmental samples and biological materials after sample preparation and to surface analysis of silicon wafers. The present paper shows some results of applications for rainwater, atmospheric particulate material, colostrum and nuclear samples. (author)

  19. Elements of quality assurance in environmental surveillance

    International Nuclear Information System (INIS)

    Johnson, L.J.

    1975-01-01

    Qualities of an environmental surveillance program requiring control or assurance are reviewed. Requirements of accuracy, reproducibility, sensitivity, acceptability, and time and cost effectiveness are qualities discussed. The controls applicable to sample collection, handling, chemical analysis, measurement and data presentation are identified and discussed as they pertain to environmental monitoring. Quality assurance program recommendations for developing and reporting environmental surveillance data are provided

  20. Preparation Of Deposited Sediment Sample By Casting Method For Environmental Study

    International Nuclear Information System (INIS)

    Hutabarat, Tommy; Ristin PI, Evarista

    2000-01-01

    The preparation of deposited sediment sample by c asting m ethod for environmental study has been carried out. This method comprises separation of size fraction and casting process. The deposited sediment samples were wet sieved to separate the size fraction of >500 mum, (250-500) mum, (125-250) mum and (63-125) mum and settling procedures were followed for the separation of (40-63) mum, (20-40) mum, (10-20) mum and o C, ashed at 450 o C, respectively. In the casting process of sample, it was used polyester rapid cure resin and methyl ethyl ketone peroxide (MEKP) hardener. The moulded sediment sample was poured onto caster, allow for 60 hours long. The aim of this method is to get the casted sample which can be used effectively, efficiently and to be avoided from contamination of each other samples. Before casting, samples were grinded up to be fine. The result shows that casting product is ready to be used for natural radionuclide analysis

  1. Hanford Environmental Information System (HEIS)

    International Nuclear Information System (INIS)

    1994-01-01

    The purpose of the Biota subject area of the Hanford Environmental Information System (HEIS) is to manage the data collected from samples of plants and animals. This includes both samples taken from the plant or animal or samples related to the plant or animal. Related samples include animal feces and animal habitat. Data stored in the Biota subject area include data about the biota samples taken, analysis results counts from population studies, and species distribution maps

  2. Development of low-level environmental sampling capabilities for uranium at Brazilian and Argentine laboratories by ABACC

    International Nuclear Information System (INIS)

    Guidicini, Olga Mafra; Hembree Junior, Doyle M.; Carter, Joel A.; Hayes, Susan; Whitaker, Michael; Olsen, Khris

    2003-01-01

    The Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC) with assistance from the U.S. Department of Energy (DOE) began a program to evaluate environmental sampling capabilities at laboratories in Argentina and Brazil in June 1998. The program included staff training conducted in South America and the United States. Several laboratory evaluation exercises were also conducted using standard swipe samples prepared by the International Atomic Energy Agency (IAEA) and a National Institute of Standards and Technology Standard Reference Material 1547, Peach Leaves. The results of these exercises demonstrated that several laboratories were capable of accurately determining the total uranium and uranium isotopic distribution in the peach leaves. To build on these successes, another exercise using standard swipe samples prepared by the IAEA was conducted. A total of 8 sets of 15 swipe samples were prepared and distributed to the six ABACC support laboratories and to two of DOE's Network of Analytical Laboratories (NWAL) that support IAEA's environmental sampling program Throughout this project, the ABACC laboratories have shown steady progress in contamination control and improvements to the accuracy and precision of their measurements. The results of the latest exercises demonstrate that ABACC now has support laboratories in both Argentina and Brazil that have the capability to measure both the amount and isotopic composition of uranium at levels expected in typical environmental samples (i.e., sub-microgram quantities). This presentation will discuss the final results for the exercise with uranium swipe samples and discuss future activities to develop measurement capabilities for total and isotopic plutonium in environmental samples. (author)

  3. The measure of radiocarbon in the drating of environmental samples

    International Nuclear Information System (INIS)

    Ruiz Pessenda, L.C.; Camargo, P.B. de

    1990-01-01

    An analytical system for radiocarbon dating of environmental samples (charcoal, shell, wood, etc.) using low level liquid scintillation spectrometry has been developed and optimized at Center for Nuclear Energy in Agriculture of the University of Sao Paulo. Physical and chemical pretreatment of samples to remove oils, resins, carbonates and fulvic and humic acids; the benzene synthesis of NBS oxalic acid standard, calcium carbonate P.A. and marble and the results of benzene yield; the optimization of radiocarbon counting window; the effect of scintillators PPO-POPOP and butyl PBD on the efficiency of detection and background of radiocarbon, are described. Samples of charcoal, shell and wood, previously dated at the radiocarbon laboratories of Centre des Faibles Radioactives, France, and Instituto de Geociencias of USP, are analysed for preliminary laboratory intercomparison. (author) [pt

  4. Establishing adequate conditions for mercury determination in environmental samples by INAA

    International Nuclear Information System (INIS)

    Perez, Caroline; Santos, Eliane C.; Saiki, Mitiko

    2017-01-01

    Mercury (Hg) is a toxic element released into the environment mainly by anthropic activities. Consequently, the improvement for Hg determination in environmental samples is of great interest. Instrumental Neutron Activation Analysis (INAA) is considered an adequate method to determine several elements. However, Hg determination by INAA is often hampered by its volatility, which causes losses. The aim of this study was to establish adequate irradiation conditions for Hg determination in environmental samples by INAA. The following parameters were evaluated: irradiation time, container for irradiation and spectral gamma ray interferences. For the study, aliquots of certified reference materials (CRMs) and tree bark samples were irradiated together with Hg synthetic standard at the IEA-R1 nuclear research reactor. Gamma ray activities of 1 97 Hg and 203 Hg were measured in a spectrometer coupled to a HGe detector. Results obtained indicated that polyethylene capsules or envelopes can be used as container for sample irradiation and the Hg impurities in these containers were negligible. Irradiation time of one hour was adequate for Hg determination and in long irradiations of 8 h problems of spectral interference of 198 Au and 75 Se were observed. In addition, Hg loss during the irradiation of 1 h and after irradiation was not observed. Quality control of Hg results, obtained in the CRMs analyses using one hour of irradiation, indicated good precision and accuracy with |Z score| < 2. The experimental conditions established in this study were applied to tree bark samples. Detection limits for Hg of these analyses were between 0.14 and 1.9 μg g -1 . (author)

  5. Design of a Clean Room for Quality Control of an Environmental Sampling in KINAC

    International Nuclear Information System (INIS)

    Yoon, Jongho; Ahn, Gil Hoon; Seo, Hana; Han, Kitek; Park, Il Jin

    2014-01-01

    The objective of environmental sampling and analysis for safeguards is to characterize the nuclear materials handled and the activities conducted at the specific locations. The KINAC is responsible for the conclusions drawn from the analytical results provided by the analytical laboratories. To assure the KINAC of the continuity of the quality of the analytical results provided by the laboratories, the KINAC will implement a quality control(QC) programme. One of the QC programme is to prepare QC samples. The establishment of a clean room is needed to handle QC samples due to stringent control of contamination. The KINAC designed a clean facility with cleanliness of ISO Class 6, the Clean Room for Estimation and Assay of trace Nuclear materials(CREAN) to meet conflicting requirements of a clean room and for handling of nuclear materials according to Korean laws. The clean room will be expected to acquire of a radiation safety license under these conditions in this year and continue to improve it. The construction of the CREAN facility will be completed by the middle of 2015. In terms of QC programme, the establishment of a clean room is essential and will be not only very helpful for setting of quality control system for the national environmental sampling programme but also be applied for the environmental sample analysis techniques to the nuclear forensics

  6. Radiometric Data Collection for Environmental Studies in Egypt

    International Nuclear Information System (INIS)

    Abdel Fattah, A.T.; Ramadan, A.A.; Gomaa, M.A.

    2001-01-01

    Radiation protection and monitoring in Egypt covers most fields of activities dealing with radioactivity. Such protection measures necessitate measurements of radiation levels, exposure or contamination whatever they are due to natural or man-made sources. A radiation level in foodstuff samples collected from selected main cities in Egypt was followed for several years after Chernobyl accident. Potassium-40 was found to be the main source of radioactivity. It ranges from 9 Bq/kg for macaroni to about 363 Bq/kg for watercress and broad beans. 137 Cs was found in trace amounts. Radiation measurements were carried out in soil samples collected from sixteen locations all over the country. The natural radiation level of 238 U, 232 Th and 40 K was found to be 7-27 Bq/kg, 3.8-24.4 Bq/kg and 105,7-448.9 Bq/kg respectively. This level was found to be higher in eastern parts of Egypt than in the western parts. Radiological control is precisely undertaken on the entry of food items and certain chemical materials used in industry. Contaminated food, higher than international trading levels, is rejected. Chemical materials containing radioactivity are followed during their uses. The annual effective dose from terrestrial gamma rays was determined for most Egyptian Governorates (106-371 UVv/y). Accordingly,the annual collective dose due to natural background radiation (terrestrial gamma rays and cosmic rays) is about 27,253 Man Sv. As a national need together with international attitude a monitoring network has been established few years after Chernobyl accident. It consists of 42 stations for gamma monitors in air,43 stations in water, 44 stations for beta aerosols, and 15 stations for conventional pollutants. The measured radiation levels are transmitted to control station via digital communication every 15 minutes

  7. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    Science.gov (United States)

    Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  8. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of Madagascar. Materials and methods: Participants were recruited in a health care center (urban group) and smaller affiliated dispensaries (rural group). They were invited to perform ...

  9. A DOE manual: DOE Methods for Evaluating Environmental and Waste Management Samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Riley, R.G.

    1994-01-01

    Waste Management inherently requires knowledge of the waste's chemical composition. The waste can often be analyzed by established methods; however, if the samples are radioactive, or are plagued by other complications, established methods may not be feasible. The US Department of Energy (DOE) has been faced with managing some waste types that are not amenable to standard or available methods, so new or modified sampling and analysis methods are required. These methods are incorporated into DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), which is a guidance/methods document for sampling and analysis activities in support of DOE sites. It is a document generated by consensus of the DOE laboratory staff and is intended to fill the gap within existing guidance documents (e. g., the Environmental Protection Agency's (EPA's) Test Methods for Evaluating Solid Waste, SW-846), which apply to low-level or non-radioactive samples. DOE Methods fills the gap by including methods that take into account the complexities of DOE site matrices. The most recent update, distributed in October 1993, contained quality assurance (QA), quality control (QC), safety, sampling, organic analysis, inorganic analysis, and radioanalytical guidance as well as 29 methods. The next update, which will be distributed in April 1994, will contain 40 methods and will therefore have greater applicability. All new methods are either peer reviewed or labeled ''draft'' methods. Draft methods were added to speed the release of methods to field personnel

  10. A radiochemical procedure for the determination of Po-210 in environmental samples

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.

    1980-07-01

    A radiochemical procedure for the determination of Po-210 in environmental samples was developed. Soil, sediments, filter materials, plants, water and food samples can be analyzed for Po-210. Wet ashing is achieved with HNO 3 + H 2 O 2 or HCl + HNO 3 . To separate disturbing substances, a coprecipitation with Te is used for sample materials containing silica. Po-210 deposition from HCl solution on Ag platelets with other sample materials is possible directly. Deposited Po-210 is counted by α-spectrometry. For chemical yield determination Po-208 is added, yields range between 60% and 100%. A lower detection limit of about 0,002 pCi Po-210/sample is achievable. (orig./HP) [de

  11. Environmental impacts of the Swiss collection and recovery systems for Waste Electrical and Electronic Equipment (WEEE): A follow-up

    International Nuclear Information System (INIS)

    Waeger, P.A.; Hischier, R.; Eugster, M.

    2011-01-01

    While Waste Electrical and Electronic Equipment (WEEE) collection and recovery have significantly gained in importance all over Europe in the last 15 years, comprehensive studies assessing the environmental loads and benefits of these systems still are not common. In this paper we present the results of a combined material flow analysis and life cycle assessment study, which aimed to calculate the overall environmental impacts of collection, pre-processing and end-processing for the existing Swiss WEEE collection and recovery systems, as well as of incineration and landfilling scenarios, in which the same amount of WEEE is either incinerated in a an MSWI plant or landfilled. According to the calculations based on the material flow data for the year 2009 and a new version of the ecoinvent life cycle inventory database (ecoinvent v2.01), collection, recovery and disposal result in significantly lower environmental impacts per t of WEEE for midpoint indicators such as global warming or ozone depletion and the endpoint indicator Eco-Indicator '99 points. A comparison between the environmental impacts of the WEEE recovery scenarios 2009 and 2004, both calculated with ecoinvent v2.01 data, shows that the impacts per t of WEEE in 2009 were slightly lower. This appears to be mainly due to the changes in the treatment of plastics (more recycling, less incineration). Compared to the overall environmental impacts of the recovery scenario 2004 obtained with an old version of ecoinvent (ecoinvent v1.1), the calculation with ecoinvent v2.01 results in an increase of the impacts by about 20%, which is primarily the consequence of a more adequate modeling of several WEEE fractions (e.g. metals, cables or CRT devices). In view of a further increase of the environmental benefits associated with the Swiss WEEE collection and recovery systems, the recovery of geochemically scarce metals should be further investigated, in particular. - Research Highlights: → Comprehensive MFA

  12. Quantification of uncertainty in gamma spectrometric analysis of food and environmental samples

    International Nuclear Information System (INIS)

    Yii Mei Wo; Zaharudin Ahmad; Norfaizal Mohamed

    2005-01-01

    Gamma Spectrometry is widely used to determine the activity of gamma-ray emitter radionuclide inside a sample. Reporting the activity of the measurement for a sample should not be a single value only but it shall be associated with a reasonable uncertainty value since disintegration of radionuclide is a random/spontaneous process. This paper will focus on how the uncertainty was estimated, quantified and calculated, when measuring the activity of Cs-134 and Cs-137 in food and Ra-226, Ra-228 and K-40 in the environmental samples. (Author)

  13. Middlesex Sampling Plant: Annual environmental report for calendar year 1990, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    1991-09-01

    Environmental monitoring of the US Department of Energy's (DOE) Middlesex Sampling Plant (MSP) and surrounding area began in 1980. MSP is part of the Formerly Utilized Sites Remedial Action Program (FUSRAP), a DOE program to decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program at MSP includes sampling networks for radon concentrations in air; external gamma radiation exposure; and radium-226, thorium-232, and total uranium concentrations in surface water, sediment, and groundwater. Additionally, several nonradiological parameters were measured in groundwater, surface water, and sediment. 14 refs., 17 figs., 29 tabs

  14. Insular Biobjective Routing with Environmental Considerations for a Solid Waste Collection System in Southern Chile

    OpenAIRE

    Daniela S. Arango González; Elias Olivares-Benitez; Pablo A. Miranda

    2017-01-01

    This paper presents a biobjective problem for a solid waste collection system in a set of islands in southern Chile. The first objective minimizes transportation cost and the second one reduces the environmental impact caused by the accumulation of solid waste at the collection points. To solve this problem, biobjective mixed integer linear programming is used. In the model, an itinerary scheme is considered for the visit to the islands. The model decides which collection points are visited p...

  15. Temporal evolution of the environmental performance of implementing selective collection in municipal waste management systems in developing countries: A Brazilian case study.

    Science.gov (United States)

    Ibáñez-Forés, Valeria; Bovea, María D; Coutinho-Nóbrega, Claudia; de Medeiros-García, Hozana R; Barreto-Lins, Raissa

    2018-02-01

    The aim of this study is to analyse the evolution of the municipal solid waste management system of João Pessoa (Brazil), which was one of the Brazilian pioneers cities in implementing door-to-door selective collection programmes, in order to analyse the effect of policy decisions adopted in last decade with regard to selective collection. To do it, this study focuses on analysing the evolution, from 2005 to 2015, of the environmental performance of the municipal solid waste management (MSWM) system implemented in different sorting units with selective collection programmes by applying the Life Cycle Assessment (LCA) methodology and using as a starting point data collected directly from the different stakeholders involved in the MSWM system. This article presents the temporal evolution of environmental indicators measuring the environmental performance of the MSWM system implemented in João Pessoa by sorting unit, for each stage of the life cycle of the waste (collection, classification, intermediate transports, recycling and landfilling), for each waste fraction and for each collection method (selective collection or mixed collection), with the aim of identifying the key aspects with the greatest environmental impact and their causes. Results show on one hand, that environmental behaviour of waste management in a door-to-door selective collection programme significantly improves the behaviour of the overall waste management system. Consequently, the potential to reduce the existing environmental impact based on citizens' increased participation in selective collection is evidenced, so the implementation of awareness-raising campaigns should be one of the main issues of the next policies on solid waste. On the other hand, increasing the amount of recyclable wastes collected selectively, implementing alternative methods for valorising the organic fraction (compost/biomethanization) and improving the efficiency of the transportation stage by means of optimizing

  16. Computer system for environmental sample analysis and data storage and analysis

    International Nuclear Information System (INIS)

    Brauer, F.P.; Fager, J.E.

    1976-01-01

    A mini-computer based environmental sample analysis and data storage system has been developed. The system is used for analytical data acquisition, computation, storage of analytical results, and tabulation of selected or derived results for data analysis, interpretation and reporting. This paper discussed the structure, performance and applications of the system

  17. Development of a reference method and sampling system for continuous monitoring of environmental HT and HTO concentration in the air

    International Nuclear Information System (INIS)

    Uchrin, G.

    1992-06-01

    A differential sampling system to monitor environmental Tritiated Water Vapour (HT) and Tritiated Hydrogen Gas (HTO) concentrations in the atmosphere was developed and tested. The sampler consists of an aerosol filter, diaphragm pump, absorption trap for HTO (molecular sieve), supply of H 2 carrier (electrolysis unit), conversion trap for HT (Pd-impregnated molecular sieve), flow meter and gas meter. The sampler operates with a flow rate between 30 and 80 1/h, with a typical sampling period of one week. Vacuum desorption at high temperature is used to extract the HTO collected in the absorption and conversion traps. Tritium analysis is carried out using liquid scintillation spectrometry or gas proportional counting. The sampler is equipped with built-in safety systems and can operate in remote places. Refs, figs and tabs

  18. Idaho National Engineering Laboratory Site environmental report for Calendar Year 1994

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, R.G.; Peterson, D. [Environmental Science and Research Foundation, Idaho Falls, ID (United States); Hoff, D.L. [USDOE Idaho Operations Office, Idaho Falls, ID (United States)

    1995-07-01

    This report presents a compilation of data collected in 1994 for routine environmental surveillance programs conducted on and around INEL. EG&G conducted the onsite surveillance program January-- September; Lockheed Idaho conducted the program October--December. The offsite surveillance program was conducted by the Environmental Science and Research Foundation. Ground water monitoring (both on and off site) was performed by USGS. This report presents summaries of facility effluent monitoring data collected by INEL contractors. It includes collection of foodstuffs at the INEL boundary and distant offsite locations, and the collection of air and water samples at onsite locations and offsite boundary and distant locations. The report also compares and evaluates the sample results to federal regulations and standards.

  19. Idaho National Engineering Laboratory Site environmental report for Calendar Year 1994

    International Nuclear Information System (INIS)

    Mitchell, R.G.; Peterson, D.; Hoff, D.L.

    1995-07-01

    This report presents a compilation of data collected in 1994 for routine environmental surveillance programs conducted on and around INEL. EG ampersand G conducted the onsite surveillance program January-- September; Lockheed Idaho conducted the program October--December. The offsite surveillance program was conducted by the Environmental Science and Research Foundation. Ground water monitoring (both on and off site) was performed by USGS. This report presents summaries of facility effluent monitoring data collected by INEL contractors. It includes collection of foodstuffs at the INEL boundary and distant offsite locations, and the collection of air and water samples at onsite locations and offsite boundary and distant locations. The report also compares and evaluates the sample results to federal regulations and standards

  20. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF SOIL SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.20)

    Science.gov (United States)

    This SOP describes the method for collecting soil samples from the child's outdoor play area to measure for persistent organic pollutants. Soil samples are collected by scraping up the top 0.5 cm of soil in a 0.095 m2 (1 ft2) area in the middle of the child's play area.

  1. Investigation of environmental conditions at Sarfartoq 1987-88. Collection of samples for testing, measurement of radon and analyses for polonium-210 and lead-210. [Greenland]. Miljoeundersoegelser ved Sarfartoq 1987-88. Proeveindsamling, radonmaaling og analyser for polonium-210 og bly-210

    Energy Technology Data Exchange (ETDEWEB)

    Aastrup, P; Munk Hansen, M

    1989-01-01

    The sampling of plants and animals is part of environmental base line studies initiated by the Mineral Resources Administration for Greenland in relation to plans for exploration and exploitation of a niobium occurence. Samples have been collected in areas expected to be influenced by mining activities and in reference areas. The collected species of plants include northern willow, Bellard's kobresia, lichen (Cetraria nivalis), and others. Samples of animals include musk oxen, reindeer, alpine hare, ptarmigan, fox, and arctic char. However, 60 samples have been analyzed for polonium-210 and lead-210. The highest concentrations were found in lichen and the lowest in muscle tissue. In many samples systematic differences between the concentrations of the two isotopes were observed indicating that polonium-210 should continue to be part of the base line study program and the monitoring program if mining is started. The observed concentrations pose no health problem. 30 kg bulk samples of the best pyrochlore ore and the rock c. 10 m on both sides of the mineralization (the side rock) were analyzed for niobium, tantalum, some trace elements, and natural radioactive isotopes. The ore sample has concentrations of 33.17% niobium, 0.4% tantalum, 0.77% uranium, and more than 0.37% rare earth elements. The concentrations of all other analyzed elements are low. The ore has very well defined boundaries and there is a very low concentration of radioactive elements in the side rock. The naturally occurring concentrations of radon have been measured at stations on top of the mineralization, within the carbonatite complex and outside the complex. The concentrations generally are very low. However, the concentrations in the complex are significantly higher than outside the complex. This reflects an elevated uranium concentration of the carbonatite complex rocks. (AB).

  2. Preconcentration of traces of radionuclides and elements with foamed polyurethane sorbents in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Palagyi, S.; Braun, T.

    1986-01-01

    The importance of preconcentration and the permanent need of efficient preconcentrating agents in environmental analysis are pointed out. Foamed polyurethane sorbents draw attention as novel agents in separation chemistry. A survey is presented of recent applications of unloaded and reagent-loaded open-cell type resilient polyurethane foams in the separation and preconcentration of radionuclides from environmental samples, and of the latest uses of these foams in the preconcentration and detection of traces of some, mainly inorganic materials in environmental samples, using radioanalytical techniques. Possible future uses of polyurethane foams in trace element detection in environmental analysis are outlined. (author)

  3. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  4. Estimation of collective effective dose equivalent from environmental radiation and radioactive materials in Japan. A preliminary study

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Noda, Yutaka; Takeshita, Mitsue; Iwai, Kazuo.

    1994-01-01

    The peaceful uses of nuclear power and radiations have been developed into a stage of practical applications for human life. Radiation causes harmful effects to human beings, although human beings receives a number of invaluable benefits from the nuclear energy and the uses of radiation. In order to examine the optimization of radiation protection in these practices, collective effective dose equivalent from environmental exposures due to natural and artificial radiations have been preliminarily evaluated using most recent data. The resultant collective doses were compared with those from medical and occupational exposures. It is noted that, in Japan, the collective effective dose from environmental radiation sources can be approximately same to that from medical exposure. (author)

  5. Improved explosive collection and detection with rationally assembled surface sampling materials

    Energy Technology Data Exchange (ETDEWEB)

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.; Cinson, Anthony D.; Ewing, Robert G.; Atkinson, David A.; Addleman, R. Shane

    2016-01-01

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

  6. Soil Sampling Plan for the transuranic storage area soil overburden and final report: Soil overburden sampling at the RWMC transuranic storage area

    International Nuclear Information System (INIS)

    Stanisich, S.N.

    1994-12-01

    This Soil Sampling Plan (SSP) has been developed to provide detailed procedural guidance for field sampling and chemical and radionuclide analysis of selected areas of soil covering waste stored at the Transuranic Storage Area (TSA) at the Idaho National Engineering Laboratory's (INEL) Radioactive Waste Management Complex (RWMC). The format and content of this SSP represents a complimentary hybrid of INEL Waste Management--Environmental Restoration Program, and Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Remedial Investigation/Feasibility Study (RI/FS) sampling guidance documentation. This sampling plan also functions as a Quality Assurance Project Plan (QAPP). The QAPP as a controlling mechanism during sampling to ensure that all data collected are valid, reliabile, and defensible. This document outlines organization, objectives and quality assurance/quality control (QA/QC) activities to achieve the desired data quality goals. The QA/QC requirements for this project are outlined in the Data Collection Quality Assurance Plan (DCQAP) for the Buried Waste Program. The DCQAP is a program plan and does not outline the site specific requirements for the scope of work covered by this SSP

  7. Study on auto-plating process time versus recovery for polonium, Po-210 in environmental sample

    International Nuclear Information System (INIS)

    Jalal Sharib; Zaharudin Ahmad; Abdul Kadir Ishak; Norfaizal Mohamed; Ahmad Sanadi Abu Bakar; Yii Mei Wo; Kamarozaman Ishak; Siti Aminah Yusoff

    2008-08-01

    This study was carried out to evaluate time effectiveness and recovery 16 samples of 4 Kuala Muda stations during auto-plating process procedures for determination Polonium, Po 210 activity concentration in environmental sample. The study was performed using Kuala Muda sediment as sample in the same methodology. The auto-plating process runs for 4, 12, 24 and 30 hours on a silver disc for 4 samples each station, and then counted for one (1) day using an alpha spectrometry counting system. The objectives for this study is to justify on time duration for auto-plating process effecting a chemical yield of Po-209.The results showed recovery are increasing versus time and constantly at 24 hour auto-plating. Its mean, 24 hour is an optimum time for auto-plating process for determination of Polonium, Po 210 activity concentration in environmental sample. (Author)

  8. Control of a Clonal Outbreak of Multidrug-Resistant Acinetobacter baumannii in a Hospital of the Basque Country after the Introduction of Environmental Cleaning Led by the Systematic Sampling from Environmental Objects.

    Science.gov (United States)

    Delgado Naranjo, Jesús; Villate Navarro, José Ignacio; Sota Busselo, Mercedes; Martínez Ruíz, Alberto; Hernández Hernández, José María; Torres Garmendia, María Pilar; Urcelay López, María Isabel

    2013-01-01

    Background. Between July 2009 and September 2010, an outbreak of multidrug-resistant (MDR) Acinetobacter baumannii was detected in one critical care unit of a tertiary hospital in the Basque Country, involving 49 infected and 16 colonized patients. The aim was to evaluate the impact of environmental cleaning and systematic sampling from environmental objects on the risk of infection by MDR A. baumannii. Methods. After systematic sampling from environmental objects and molecular typing of all new MDR A. baumannii strains from patients and environmental isolates, we analyzed the correlation (Pearson's r) between new infected cases and positive environmental samples. The risk ratio (RR) of infection was estimated with Poisson regression. Results. The risk increased significantly with the number of positive samples in common areas (RR = 1.40; 95%CI = 0.99-1.94) and positive samples in boxes (RR = 1.19; 95%CI = 1.01-1.40). The number of cases also positively correlated with positive samples in boxes (r = 0.50; P systematic sampling from environmental objects, provided the objective risk reduction of new cases and enabled the full control of the outbreak.

  9. Oak Ridge Reservation, annual site environmental report for 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-11-01

    The US DOE currently oversees activities on the Oak Ridge Reservation, a government-owned, contractor-operated facility. Three sites compose the reservation; Y-12, Oak Ridge National Laboratory, and K-25. This document contains a summary of environmental monitoring activities on the Oak Ridge Reservation (ORR) and its surroundings. The results summarized in this report are based on the data collected during calendar year (CY) 1993 and compiled in; Environmental Monitoring in the Oak Ridge Reservation: CY 1993 Results. Annual environmental monitoring on the ORR consists of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring is the collection and analysis of samples or measurements of liquid, gaseous, or airborne effluents for the purpose of characterizing and quantifying contaminants and process stream characteristics, assessing radiation and chemical exposures to members of the public, and demonstrating compliance with applicable standards. Environmental surveillance is the collection and analysis of samples of air, water, soil, foodstuffs, biota, and other media from DOE sites and their environs and the measurement of external radiation for purposes of demonstrating compliance with applicable standards, assessing radiation and chemical exposures to members of the public, and assessing effects, if any, on the local environment.

  10. Oak Ridge Reservation, annual site environmental report for 1993

    International Nuclear Information System (INIS)

    1994-11-01

    The US DOE currently oversees activities on the Oak Ridge Reservation, a government-owned, contractor-operated facility. Three sites compose the reservation; Y-12, Oak Ridge National Laboratory, and K-25. This document contains a summary of environmental monitoring activities on the Oak Ridge Reservation (ORR) and its surroundings. The results summarized in this report are based on the data collected during calendar year (CY) 1993 and compiled in; Environmental Monitoring in the Oak Ridge Reservation: CY 1993 Results. Annual environmental monitoring on the ORR consists of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring is the collection and analysis of samples or measurements of liquid, gaseous, or airborne effluents for the purpose of characterizing and quantifying contaminants and process stream characteristics, assessing radiation and chemical exposures to members of the public, and demonstrating compliance with applicable standards. Environmental surveillance is the collection and analysis of samples of air, water, soil, foodstuffs, biota, and other media from DOE sites and their environs and the measurement of external radiation for purposes of demonstrating compliance with applicable standards, assessing radiation and chemical exposures to members of the public, and assessing effects, if any, on the local environment

  11. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hong-geller, Elizabeth [Los Alamos National Laboratory; Valdez, Yolanda E [Los Alamos National Laboratory; Shou, Yulin [Los Alamos National Laboratory; Yoshida, Thomas M [Los Alamos National Laboratory; Marrone, Babetta L [Los Alamos National Laboratory; Dunbar, John [Los Alamos National Laboratory

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  12. Stability of volatile organics in environmental soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Maskarinec, M.P.; Bayne, C.K.; Jenkins, R.A.; Johnson, L.H.; Holladay, S.K.

    1992-11-01

    This report focuses on data generated for the purpose of establishing the stability of 19 volatile organic compounds in environmental soil samples. The study was carried out over a 56 day (for two soils) and a 111 day (for one reference soil) time frame and took into account as many variables as possible within the constraints of budget and time. The objectives of the study were: 1) to provide a data base which could be used to provide guidance on pre-analytical holding times for regulatory purposes; and 2) to provide a basis for the evaluation of data which is generated outside of the currently allowable holding times.

  13. Efficacy of passive sampler collection for atmospheric NO2 isotopes under simulated environmental conditions.

    Science.gov (United States)

    Coughlin, Justin G; Yu, Zhongjie; Elliott, Emily M

    2017-07-30

    Nitrogen oxides or NO x (NO x = NO + NO 2 ) play an important role in air quality, atmospheric chemistry, and climate. The isotopic compositions of anthropogenic and natural NO 2 sources are wide-ranging, and they can be used to constrain sources of ambient NO 2 and associated atmospheric deposition of nitrogen compounds. While passive sample collection of NO 2 isotopes has been used in field studies to determine NO x source influences on atmospheric deposition, this approach has not been evaluated for accuracy or precision under different environmental conditions. The efficacy of NO 2 passive sampler collection for NO 2 isotopes was evaluated under varied temperature and relative humidity (RH) conditions in a dynamic flux chamber. The precision and accuracy of the filter NO 2 collection as nitrite (NO 2 - ) for isotopic analysis were determined using a reference NO 2 gas tank and through inter-calibration with a modified EPA Method 7. The bacterial denitrifer method was used to convert 20 μM of collected NO 2 - or nitrate (NO 3 - ) into N 2 O and was carried out on an Isoprime continuous flow isotope ratio mass spectrometer. δ 15 N-NO 2 values determined from passive NO 2 collection, in conditions of 11-34 °C, 1-78% RH, have an overall accuracy and precision of ±2.1 ‰, and individual run precision of ±0.6 ‰. δ 18 O-NO 2 values obtained from passive NO 2 sampler collection, under the same conditions, have an overall precision of ± 1.3 ‰. Suitable conditions for passive sampler collection of NO 2 isotopes are in environments ranging from 11 to 34 °C and 1 to 78% RH. The passive NO 2 isotope measurement technique provides an accurate method to determine variations in atmospheric δ 15 N-NO 2 values and a precise method for determining atmospheric δ 18 O-NO 2 values. The ability to measure NO 2 isotopes over spatial gradients at the same temporal resolution provides a unique perspective on the extent and seasonality of fluctuations in atmospheric NO 2

  14. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Science.gov (United States)

    2010-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§ 864.3260...

  15. Normalisation of spot urine samples to 24-h collection for assessment of exposure to uranium

    International Nuclear Information System (INIS)

    Marco, R.; Katorza, E.; Gonen, R.; German, U.; Tshuva, A.; Pelled, O.; Paz-tal, O.; Adout, A.; Karpas, Z.

    2008-01-01

    For dose assessment of workers at Nuclear Research Center Negev exposed to natural uranium, spot urine samples are analysed and the results are normalised to 24-h urine excretion based on 'standard' man urine volume of 1.6 l d -1 . In the present work, the urine volume, uranium level and creatinine concentration were determined in two or three 24-h urine collections from 133 male workers (319 samples) and 33 female workers (88 samples). Three volunteers provided urine spot samples from each voiding during a 24-h period and a good correlation was found between the relative level of creatinine and uranium in spot samples collected from the same individual. The results show that normalisation of uranium concentration to creatinine in a spot sample represents the 24-h content of uranium better than normalisation to the standard volume and may be used to reduce the uncertainty of dose assessment based on spot samples. (authors)

  16. Effect of environmental and behavioral interventions on pain intensity in preterm infants for heel prick blood sampling in the neonatal intensive care unit

    Directory of Open Access Journals (Sweden)

    Fatemeh Baharlooei

    2017-01-01

    Full Text Available Background: Recent researches suggest that preterm infants understand pain and stress. Because of the wide range of effects of pain on infants, the present study was conducted on the effect of environmental and behavioral interventions on pain due to heel-prick blood sampling in preterm infants. Materials and Methods: A clinical trial was conducted among 32 infants with gestational age of 32–37 weeks in the intervention and control groups. The effects of noise reduction by earplugs, light reduction by blindfolds, reduction of nursing manipulation, and creation of intrauterine position for neonates, 30 minutes before taking blood samples until 30 minutes after it, were measured during the intervention stage. Data were collected using the Neonatal Infant Pain Scale (NIPS in 5 stages (before intervention, 2 minutes before sampling, during the sampling, and 5 minutes and 30 minutes after the sampling. The data were analyzed using analysis of variance (ANOVA and paired t-test in SPSS software. Results: The paired t-test results showed no significant differences between the control and intervention stages in terms of pain scores at base time (P = 0.42 and 2 minutes before sampling (P = 0.12. However, at the sampling time (P = 0.0, and 5 minutes (P = 0.001 and 30 minutes after the sampling (P = 0.001, mean pain score in the intervention stage was significantly less than that in the control stage. Conclusions: Based on the findings, environmental and behavioral interventions reduced pain and facilitated heel-prick blood sampling in preterm infants.

  17. LIIS: A web-based system for culture collections and sample annotation

    Directory of Open Access Journals (Sweden)

    Matthew S Forster

    2014-04-01

    Full Text Available The Lab Information Indexing System (LIIS is a web-driven database application for laboratories looking to store their sample or culture metadata on a central server. The design was driven by a need to replace traditional paper storage with an easier to search format, and extend current spreadsheet storage methods. The system supports the import and export of CSV spreadsheets, and stores general metadata designed to complement the environmental packages provided by the Genomic Standards Consortium. The goals of the LIIS are to simplify the storage and archival processes and to provide an easy to access library of laboratory annotations. The program will find utility in microbial ecology laboratories or any lab that needs to annotate samples/cultures.

  18. Planning Considerations Related to Collecting and Analyzing Samples of the Martian Soils

    Science.gov (United States)

    Liu, Yang; Mellon, Mike T.; Ming, Douglas W.; Morris, Richard V.; Noble, Sarah K.; Sullivan, Robert J.; Taylor, Lawrence A.; Beaty, David W.

    2014-01-01

    The Mars Sample Return (MSR) End-to-End International Science Analysis Group (E2E-iSAG [1]) established scientific objectives associ-ated with Mars returned-sample science that require the return and investigation of one or more soil samples. Soil is defined here as loose, unconsolidated materials with no implication for the presence or absence of or-ganic components. The proposed Mars 2020 (M-2020) rover is likely to collect and cache soil in addition to rock samples [2], which could be followed by future sample retrieval and return missions. Here we discuss key scientific consid-erations for sampling and caching soil samples on the proposed M-2020 rover, as well as the state in which samples would need to be preserved when received by analysts on Earth. We are seeking feedback on these draft plans as input to mission requirement formulation. A related planning exercise on rocks is reported in an accompanying abstract [3].

  19. Establishing adequate conditions for mercury determination in environmental samples by INAA

    Energy Technology Data Exchange (ETDEWEB)

    Perez, Caroline; Santos, Eliane C.; Saiki, Mitiko, E-mail: caroline.perez@usp.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Mercury (Hg) is a toxic element released into the environment mainly by anthropic activities. Consequently, the improvement for Hg determination in environmental samples is of great interest. Instrumental Neutron Activation Analysis (INAA) is considered an adequate method to determine several elements. However, Hg determination by INAA is often hampered by its volatility, which causes losses. The aim of this study was to establish adequate irradiation conditions for Hg determination in environmental samples by INAA. The following parameters were evaluated: irradiation time, container for irradiation and spectral gamma ray interferences. For the study, aliquots of certified reference materials (CRMs) and tree bark samples were irradiated together with Hg synthetic standard at the IEA-R1 nuclear research reactor. Gamma ray activities of 1{sup 97}Hg and {sup 203}Hg were measured in a spectrometer coupled to a HGe detector. Results obtained indicated that polyethylene capsules or envelopes can be used as container for sample irradiation and the Hg impurities in these containers were negligible. Irradiation time of one hour was adequate for Hg determination and in long irradiations of 8 h problems of spectral interference of {sup 198}Au and {sup 75}Se were observed. In addition, Hg loss during the irradiation of 1 h and after irradiation was not observed. Quality control of Hg results, obtained in the CRMs analyses using one hour of irradiation, indicated good precision and accuracy with |Z score| < 2. The experimental conditions established in this study were applied to tree bark samples. Detection limits for Hg of these analyses were between 0.14 and 1.9 μg g{sup -1}. (author)

  20. Radionuclide determination in environmental samples by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lariviere, Dominic; Taylor, Vivien F.; Evans, R. Douglas; Cornett, R. Jack

    2006-01-01

    The determination of naturally occurring and anthropogenic radionuclides in the environment by inductively coupled plasma mass spectrometry has gained recognition over the last fifteen years, relative to radiometric techniques, as the result of improvement in instrumental performance, sample introduction equipment, and sample preparation. With the increase in instrumental sensitivity, it is now possible to measure ultratrace levels (fg range) of many radioisotopes, including those with half-lives between 1 and 1000 years, without requiring very complex sample pre-concentration schemes. However, the identification and quantification of radioisotopes in environmental matrices is still hampered by a variety of analytical issues such as spectral (both atomic and molecular ions) and non-spectral (matrix effect) interferences and instrumental limitations (e.g., abundance sensitivity). The scope of this review is to highlight recent analytical progress and issues associated with the determination of radionuclides by inductively coupled plasma mass spectrometry. The impact of interferences, instrumental limitations (e.g., degree of ionization, abundance sensitivity, detection limits) and low sample-to-plasma transfer efficiency on the measurement of radionuclides by inductively coupled plasma mass spectrometry will be described. Solutions that overcome these issues will be discussed, highlighting their pros and cons and assessing their impact on the measurement of environmental radioactivity. Among the solutions proposed, mass and chemical resolution through the use of sector-field instruments and chemical reactions/collisions in a pressurized cell, respectively, will be described. Other methods, such as unique sample introduction equipment (e.g., laser ablation, electrothermal vaporisation, high efficiency nebulization) and instrumental modifications/optimizations (e.g., instrumental vacuum, radiofrequency power, guard electrode) that improve sensitivity and performance