WorldWideScience

Sample records for environmental chamber study

  1. Climate chamber for environmentally controlled laboratory airflow experiments.

    Science.gov (United States)

    Even-Tzur, Nurit; Zaretsky, Uri; Grinberg, Orly; Davidovich, Tomer; Kloog, Yoel; Wolf, Michael; Elad, David

    2010-01-01

    Climate chambers have been widely used in in vitro and in vivo studies which require controlled environmental temperature and humidity conditions. This article describes a new desktop climate chamber that was developed for application of respiratory airflows on cultured nasal epithelial cells (NEC) under controlled temperature and humidity conditions. Flow experiments were performed by connecting the climate chamber to an airflow generator via a flow chamber with cultured NEC. Experiments at two controlled climate conditions, 25 degrees C and 40% relative humidity (RH) and 37 degrees C and 80%RH, were conducted to study mucin secretion from the cultures inresponse to the flow. The new climate chamber is a relatively simple and inexpensive apparatus which can easily be connected to any flow system for climate controlled flow experiments. This chamber can be easily adjusted to various in vitro experiments, as well as to clinical studies with animals or human subjects which require controlled climate conditions.

  2. Environmental aging in polycrystalline-Si photovoltaic modules: comparison of chamber-based accelerated degradation studies with field-test data

    Science.gov (United States)

    Lai, T.; Biggie, R.; Brooks, A.; Potter, B. G.; Simmons-Potter, K.

    2015-09-01

    Lifecycle degradation testing of photovoltaic (PV) modules in accelerated-degradation chambers can enable the prediction both of PV performance lifetimes and of return-on-investment for installations of PV systems. With degradation results strongly dependent on chamber test parameters, the validity of such studies relative to fielded, installed PV systems must be determined. In the present work, accelerated aging of a 250 W polycrystalline silicon module is compared to real-time performance degradation in a similar polycrystalline-silicon, fielded, PV technology that has been operating since October 2013. Investigation of environmental aging effects are performed in a full-scale, industrial-standard environmental chamber equipped with single-sun irradiance capability providing illumination uniformity of 98% over a 2 x 1.6 m area. Time-dependent, photovoltaic performance (J-V) is evaluated over a recurring, compressed night-day cycle providing representative local daily solar insolation for the southwestern United States, followed by dark (night) cycling. This cycle is synchronized with thermal and humidity environmental variations that are designed to mimic, as closely as possible, test-yard conditions specific to a 12 month weather profile for a fielded system in Tucson, AZ. Results confirm the impact of environmental conditions on the module long-term performance. While the effects of temperature de-rating can be clearly seen in the data, removal of these effects enables the clear interpretation of module efficiency degradation with time and environmental exposure. With the temperature-dependent effect removed, the normalized efficiency is computed and compared to performance results from another panel of similar technology that has previously experienced identical climate changes in the test yard. Analysis of relative PV module efficiency degradation for the chamber-tested system shows good comparison to the field-tested system with ~2.5% degradation following

  3. Radiation Target Area Sample Environmental Chamber (RTASEC), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Payload Systems Inc. proposes the Radiation Target Area Sample Environmental Chamber (RTASEC) as an innovative approach enabling radiobiologists to investigate the...

  4. HVAC&R Equipment Environmental Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — Description:Large "Truck" ChamberThe large "truck" chamber provides controlled air conditions from -7 °C (20 °F) to 65 °C (150 °F).Air-Conditioner and Heat Pump Test...

  5. Nova target chamber decontamination study

    International Nuclear Information System (INIS)

    1979-05-01

    An engineering study was performed to determine the most effective method for decontamination of the Nova target chamber. Manual and remote decontamination methods currently being used were surveyed. In addition, a concept that may not require in-situ decontamination was investigated. Based on the presently available information concerning material and system compatibility and particle penetration, it is recommended that a system of removable aluminum shields be considered. It is also recommended that a series of tests be performed to more precisely determine the vacuum compatibility and penetrability of other materials discussed in this report

  6. D0 central tracking chamber performance studies

    International Nuclear Information System (INIS)

    Pizzuto, D.

    1991-12-01

    The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an RΦ tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against γ → e + e - events

  7. Temperature Studies for ATLAS MDT BOS Chambers

    CERN Document Server

    Engl, A.; Biebel, O.; Mameghani, R.; Merkl, D.; Rauscher, F.; Schaile, D.; Ströhmer, R.

    Data sets with high statistics taken at the cosmic ray facility, equipped with 3 ATLAS BOS MDT chambers, in Garching (Munich) have been used to study temperature and pressure effects on gas gain and drifttime. The deformation of a thermally expanded chamber was reconstructed using the internal RasNik alignment monitoring system and the tracks from cosmic data. For these studies a heating system was designed to increase the temperature of the middle chamber by up to 20 Kelvins over room temperature. For comparison the temperature effects on gas properties have been simulated with Garfield. The maximum drifttime decreased under temperature raise by -2.21 +- 0.08 ns/K, in agreement with the results of pressure variations and the Garfield simulation. The increased temperatures led to a linear increase of the gas gain of about 2.1% 1/K. The chamber deformation has been analyzed with the help of reconstructed tracks. By the comparison of the tracks through the reference chambers with these through the test chamber ...

  8. Final report for NIF chamber dynamics studies

    International Nuclear Information System (INIS)

    Burnham, A; Peterson, P F; Scott, J M

    1998-01-01

    The National Ignition Facility (NIF), a 1.8 MJ, 192 laser beam facility, will have anticipated fusion yields of up to 20 MJ from D-T pellets encased in a gold hohlraum target. The energy emitted from the target in the form of x rays, neutrons, target debris kinetic energy, and target shrapnel will be contained in a 5 m. radius spherical target chamber. various diagnostics will be stationed around the target at varying distances from the target. During each shot, the target will emit x rays that will vaporize nearby target facing surfaces including those of the diagnostics, the target positioner, and other chamber structures. This ablated vapor will be transported throughout the chamber, and will eventually condense and deposit on surfaces in the chamber, including the final optics debris shields. The research at the University of California at Berkeley relates primarily to the NIF chamber dynamics. The key design issues are the ablation of the chamber structures, transport of the vapor through the chamber and the condensation or deposition processes of those vaporized materials. An understanding of these processes is essential in developing a concept for protecting the fina optics debris shields from an excessive coating (> 10 A) of target debris and ablated material, thereby prolonging their lifetime between change-outs. At Berkeley, we have studied the physical issues of the ablation process and the effects of varying materials, the condensation process of the vaporized material, and design schemes that can lower the threat posed to the debris shields by these processes. The work or portions of the work completed this year have been published in several papers and a dissertation [l-5

  9. Mimicking Mars: A vacuum simulation chamber for testing environmental instrumentation for Mars exploration

    Energy Technology Data Exchange (ETDEWEB)

    Sobrado, J. M., E-mail: sobradovj@inta.es; Martín-Soler, J. [Centro de Astrobiología (CAB), INTA-CSIC, Torrejón de Ardoz, 28850 Madrid (Spain); Martín-Gago, J. A. [Centro de Astrobiología (CAB), INTA-CSIC, Torrejón de Ardoz, 28850 Madrid (Spain); Instituto de Ciencias de Materiales de Madrid (ICMM-CSIC), Cantoblanco, 28049 Madrid (Spain)

    2014-03-15

    We have built a Mars environmental simulation chamber, designed to test new electromechanical devices and instruments that could be used in space missions. We have developed this environmental system aiming at validating the meteorological station Rover Environment Monitoring Station of NASA's Mars Science Laboratory mission currently installed on Curiosity rover. The vacuum chamber has been built following a modular configuration and operates at pressures ranging from 1000 to 10{sup −6} mbars, and it is possible to control the gas composition (the atmosphere) within this pressure range. The device (or sample) under study can be irradiated by an ultraviolet source and its temperature can be controlled in the range from 108 to 423 K. As an important improvement with respect to other simulation chambers, the atmospheric gas into the experimental chamber is cooled at the walls by the use of liquid-nitrogen heat exchangers. This chamber incorporates a dust generation mechanism designed to study Martian-dust deposition while modifying the conditions of temperature, and UV irradiated.

  10. Mimicking Mars: a vacuum simulation chamber for testing environmental instrumentation for Mars exploration.

    Science.gov (United States)

    Sobrado, J M; Martín-Soler, J; Martín-Gago, J A

    2014-03-01

    We have built a Mars environmental simulation chamber, designed to test new electromechanical devices and instruments that could be used in space missions. We have developed this environmental system aiming at validating the meteorological station Rover Environment Monitoring Station of NASA's Mars Science Laboratory mission currently installed on Curiosity rover. The vacuum chamber has been built following a modular configuration and operates at pressures ranging from 1000 to 10(-6) mbars, and it is possible to control the gas composition (the atmosphere) within this pressure range. The device (or sample) under study can be irradiated by an ultraviolet source and its temperature can be controlled in the range from 108 to 423 K. As an important improvement with respect to other simulation chambers, the atmospheric gas into the experimental chamber is cooled at the walls by the use of liquid-nitrogen heat exchangers. This chamber incorporates a dust generation mechanism designed to study Martian-dust deposition while modifying the conditions of temperature, and UV irradiated.

  11. Quality assurance for radon exposure chambers at the National Air and Radiation Environmental Laboratory, Montgomery, Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Semler, M.O.; Sensintaffar, E.L. [National Air and Radiation Environmental Laboratory, Montgomery, AL (United States)

    1993-12-31

    The Office of Radiation and Indoor Air, U.S. Environmental Protection Agency (EPA), operates six radon exposure chambers in its two laboratories, the National Air and Radiation Environmental Laboratory (NAREL) in Montgomery, Alabama, and the Las Vegas Facility, Las Vegas, Nevada. These radon exposure chambers are used to calibrate and test portable radon measuring instruments, test commercial suppliers of radon measurement services through the Radon Measurement Proficiency Program, and expose passive measurement devices to known radon concentrations as part of a quality assurance plan for federal and state studies measuring indoor radon concentrations. Both laboratories participate in national and international intercomparisons for the measurement of radon and are presently working with the National Institute of Standards and Technology (NIST) to receive a certificate of traceability for radon measurements. NAREL has developed an estimate of the total error in its calibration of each chamber`s continuous monitors as part of an internal quality assurance program. This paper discusses the continuous monitors and their calibration for the three chambers located in Montgomery, Alabama, as well as the results of the authors intercomparisons and total error analysis.

  12. Inertial confinement fusion reaction chamber and power conversion system study

    International Nuclear Information System (INIS)

    Maya, I.; Schultz, K.R.; Battaglia, J.M.

    1984-09-01

    GA Technologies has developed a conceptual ICF reactor system based on the Cascade rotating-bed reaction chamber concept. Unique features of the system design include the use of low activation SiC in a reaction chamber constructed of box-shaped tiles held together in compression by prestressing tendons to the vacuum chamber. Circulating Li 2 O granules serve as the tritium breeding and energy transport material, cascading down the sides of the reaction chamber to the power conversion system. The total tritium inventory of the system is 6 kg; tritium recovery is accomplished directly from the granules via the vacuum system. A system for centrifugal throw transport of the hot Li 2 O granules from the reaction chamber to the power conversion system has been developed. A number of issues were evaluated during the course of this study. These include the response of first-layer granules to the intense microexplosion surface heat flux, cost effective fabrication of Li 2 O granules, tritium inventory and recovery issues, the thermodynamics of solids-flow options, vacuum versus helium-medium heat transfer, and the tradeoffs of capital cost versus efficiency for alternate heat exchange and power conversion system option. The resultant design options appear to be economically competitive, safe, and environmentally attractive

  13. Conceptual design study of the hylife lithium waterfall laser fusion chamber. FY 1978 annual report to Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    1978-01-01

    Conceptual design studies of the target chamber defined the general configuration and dimensions of the chamber and the inlet plenum, orifice plate, and nozzle plate concepts required to generate the desired lithium jet fall. Preliminary studies were performed of the target chamber interfaces with the liquid lithium supply system, the laser system, the pellet injection system, and the target chamber mounting and support system. Target chamber environmental effects resulting from typical thermonuclear burns were evaluated. The outlet region of the target chamber was outlined conceptually, and preliminary design considerations were given to the annular graphite reflector regions of the target chamber and the associated liquid lithium coolant passages

  14. Environmental studies

    International Nuclear Information System (INIS)

    Mohd Tadza Abd Rahman

    2003-01-01

    Nuclear Technology offers unique method, yet effective for environmental research. Nuclear techniques are invented to carry out research activities on environmental pollutions, erosion and slope stability, landslide ground water studies and water pollution

  15. 21 CFR 864.9575 - Environmental chamber for storage of platelet concentrate.

    Science.gov (United States)

    2010-04-01

    ... to hold platelet-rich plasma within a preselected temperature range. (b) Classification. Class II... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Environmental chamber for storage of platelet... Establishments That Manufacture Blood and Blood Products § 864.9575 Environmental chamber for storage of platelet...

  16. Plant exposure chambers for study of toxic chemical-plant interactions (journal version)

    International Nuclear Information System (INIS)

    McFarlane, J.C.; Pfleeger, T.

    1987-01-01

    Chambers for the study of plant uptake and phytotoxicity of toxic, radio-labeled chemicals are described. The chambers are designed to meet the criteria of continuously stirred tank reactors while providing containment for toxic chemicals. They are computer managed and operated within a controlled-environment room. Besides providing controlled conditions within the contained spaces, continuous measurements are made of various environmental parameters and plant transpiration, net photosynthesis, and dark respiration in up to 18 separate chambers

  17. Evaluation of tecniques for controlling UF6 release clouds in the GAT environmental chamber

    International Nuclear Information System (INIS)

    Lux, C.J.

    1982-01-01

    Studies designed to characterize the reaction between UF 6 and atmospheric moisture, evaluate environmental variables of UF 6 cloud formation and ultimate cloud fate, and UF 6 release cloud control procedure have been conducted in the 1200 cu. ft. GAT environmental chamber. In earlier chamber experiments, 30 separate UF 6 release tests indicated that variations of atmospheric conditions and sample sizes had no significant effect on UO 2 F 2 particle size distribution, release cloud formation, or cloud settling rates. During the past year, numerous procedures have been evaluated for accelerating UF 6 cloud knockdown in a series of 37 environmental chamber releases. Knockdown procedures included: coarse water spray; air jet; steam spray (electrostatically charged and uncharged); carbon dioxide; Freon-12; fine water mist (uncharged); boric acid mist (charged and uncharged); and an ionized dry air stream. UF 6 hydrolysis cloud settling rates monitored by a laser/powermeter densitometer, indicated the relative effectiveness of various cloud knockdown techniques. Electrostatically charged boric acid/water mist, and electrostatically ionized dry air were both found to be very effective, knocking down the UO 2 F 2 release cloud particles in two to five minutes. Work to adapt these knockdown techniques for use under field conditions is continuing, taking into account recovery of the released uranium as well as nuclear criticality constraints

  18. An environmental chamber for investigating the evaporation of volatile chemicals.

    Science.gov (United States)

    Dillon, H K; Rumph, P F

    1998-03-01

    An inexpensive test chamber has been constructed that provides an environment appropriate for testing the effects of temperature and chemical interactions on gaseous emissions from test solutions. Temperature, relative humidity, and ventilation rate can be controlled and a well-mixed atmosphere can be maintained. The system is relatively simple and relies on heated tap water or ice to adjust the temperature. Temperatures ranging from 9 to 21 degrees C have been maintained. At an average temperature of 15.1 degrees C, temperatures at any location within the chamber vary by no more than 0.5 degree C, and the temperature of the test solution within the chamber varies by no more than 0.1 degree C. The temperatures within the chamber are stable enough to generate precise steady-state concentrations. The wind velocities within the chamber are reproducible from run to run. Consequently, the effect of velocity on the rate of evaporation of a test chemical is expected to be uniform from run to run. Steady-state concentrations can be attained in less than 1 hour at an air exchange rate of about 5 per hour.

  19. Variable g- Mars environmental chamber: a small window of the martian environment for life science investigations

    Science.gov (United States)

    Sgambati, Antonella; Slenzka, Klaus; Schmeyers, Bernd; Di Capua, Massimiliano; Harting, Benjamin

    Human exploration and permanent settlement on the Martian surface is the one of the most attractive and ambitious endeavors mankind has ever faced. As technology and research progress, solutions and information that were before unavailable are slowly making the dream become everyday more feasible. In the past years a huge amount of knowledge was gathered by the Mars Exploration Rovers Spirit and Opportunity and now, even more insight is being gathered through the latest rover of the family, Curiosity. In this work, data from the various missions will be used to define and reproduce on Earth the characteristic Martian atmospheric conditions. A small Mars environmental chamber has been designed and built with the objective of studying the effects of the Martian environment on biological systems. The Variable gravity Mars Environmental Chamber (VgMEC) will allow researchers to replicate atmospheric pressure, gas composition, temperature and UVA/B exposure typical of the equatorial regions of Mars. By exposing biological systems to a controllable set of stressor it will be possible to identify both multi and single stressor effects on the system of interest. While several Mars environment simulation facilities exist, due to their size and mass, all are confined to floor-fixed laboratory settings. The VgMEC is an OHB funded project that wishes to bring together the scientific community and the industry. Collaborations will be enabled by granting low cost access to cutting-edge instrumentation and services. Developed at OHB System AG, VgMEC has been designed from the ground up to be a 28L, compact and lightweight test volume capable of being integrated in existing centrifuges (such as the ESA-ESTEC LCD), gimbal systems and parabolic flight aircraft. The VgMEC support systems were designed to accommodate continuous operations of virtually unlimited duration through the adoption of solutions such as: hot swappable gas/liquid consumables bottles, low power requirements, an

  20. Planetary Simulation Chambers bring Mars to laboratory studies

    Energy Technology Data Exchange (ETDEWEB)

    Mateo-Marti, E.

    2016-07-01

    Although space missions provide fundamental and unique knowledge for planetary exploration, they are always costly and extremely time-consuming. Due to the obvious technical and economical limitations of in-situ planetary exploration, laboratory simulations are among the most feasible research options for making advances in planetary exploration. Therefore, laboratory simulations of planetary environments are a necessary and complementary option to expensive space missions. Simulation chambers are economical, more versatile, and allow for a higher number of experiments than space missions. Laboratory-based facilities are able to mimic the conditions found in the atmospheres and on the surfaces of a majority of planetary objects. Number of relevant applications in Mars planetary exploration will be described in order to provide an understanding about the potential and flexibility of planetary simulation chambers systems: mainly, stability and presence of certain minerals on Mars surface; and microorganisms potential habitability under planetary environmental conditions would be studied. Therefore, simulation chambers will be a promising tools and necessary platform to design future planetary space mission and to validate in-situ measurements from orbital or rover observations. (Author)

  1. Environmental Chambers (-10°C to 50°C)

    Data.gov (United States)

    Federal Laboratory Consortium — USARIEM has environmental and biophysical evaluation chambers of various sizes that can be controlled for temperature (-10°C to 50°C), relative humidity, and wind...

  2. Spherical ionization chamber of 14 liter for precise measurement of environmental radiation dose rate

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Saito, Kimiaki; Moriuchi, Shigeru

    1991-05-01

    A spherical ionization chamber of 14 liter filled with 1 atm. nitrogen gas was arranged aiming at precise measurement of dose rate due to environmental gamma rays and cosmic rays. Ionization current-dose rate conversion factor for this ionization chamber was derived from careful consideration taking into account the attenuation by chamber wall, ionization current due to alpha particles and so on. Experiments at calibrated gamma ray fields and intercomparison with NaI(Tl) scintillation detector were also performed, which confirmed this ionization chamber using the conversion factor can measure the dose rate with an error of only a few percent. This ionization chamber will be used for measurement of environmental gamma ray and cosmic ray dose rate. (author)

  3. Study and analysis of drift chamber parameters

    International Nuclear Information System (INIS)

    Martinez Laso, L.

    1988-01-01

    The present work deals mainly with drift chambers. In the first chapter a summary of drift chamber properties is presented. The information has been collected from the extensive bibliography available in this field. A very simple calculation procedure of drift chamber parameters has been developed and is presented in detail in the second chapter. Some prototypes have been made following two geometries (multidrift chamber and Z-chambers). Several installations have been used for test and calibration of these prototypes. A complete description of these installations is given in the third chapter. Cosmic rays, beta particles from a Ru106 radiactive source and a test beam in the WA (West Area) of SPS at CERN have been used for experimental purposes. The analysis and the results are described for the different setups. The experimental measurements have been used to produce a complete cell parametrization (position as function of drift time) and to obtain spatial resolution values (in the range of 200-250 um). Experimental results are in good agreement with numerical calculations. (Author)

  4. Environmental gamma radiation monitoring system with a large volume air ionization chamber

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, C.; Witzani, J.

    1986-01-01

    An improved environmental monitoring system has been designed and tested consisting of an ionization chamber with 120 l sensitive volume, operated at atmospheric pressure, and a commercial electrometer amplifier with digital voltmeter. The system is controlled by a desk calculator with printer for automated operation and calculation of dose and doserate. The ionization chamber provides superior dosimetric performance as compared to usual GM-counters and high pressure chambers. The system has been field-tested during the 'European Intercomparison Programme for Environmental Monitoring Instruments' organized by the Commission of the European Communities. (Author)

  5. Development & Characterization of a Whole Plant Chamber for the Investigation of Environmental Perturbations on Biogenic VOC Emissions

    Science.gov (United States)

    Holder, J.; Riches, M.; Abeleira, A.; Farmer, D.

    2017-12-01

    Accurate prediction of both climate and air quality under a changing earth system requires a full understanding of the sources, feedbacks, and ultimate fate of all atmospherically relevant chemical species, including volatile organic compounds (VOCs). Biogenic VOCs (BVOC) from plant emissions are the main source of VOCs to the atmosphere. However, the impact of global change on BVOC emissions is poorly understood. For example, while short-term increases in temperature are typically associated with increased BVOC emissions, the impact of long-term temperature increases are less clear. Our study aims to investigate the effects of long-term, singular and combined environmental perturbations on plant BVOC emissions through the use of whole plant chambers in order to better understand the effects of global change on BVOC-climate-air quality feedbacks. To fill this knowledge gap and provide a fundamental understanding of how BVOC emissions respond to environmental perturbations, specifically elevated temperature, CO2, and drought, whole citrus trees were placed in home-built chambers and monitored for monoterpene and other BVOC emissions utilizing thermal desorption gas chromatography mass spectrometry (TD-GC-MS). Designing and building a robust whole plant chamber to study atmospherically relevant chemical species while accommodating the needs of live plants over timescales of days to weeks is not a trivial task. The environmental conditions within the chamber must be carefully controlled and monitored. The inter-plant and chamber variability must be characterized. Finally, target BVOCs need to be sampled and detected from the chamber. Thus, the chamber design, control and characterization considerations along with preliminary BVOC results will be presented and discussed.

  6. A Facility for Long-Term Mars Simulation Experiments: The Mars Environmental Simulation Chamber (MESCH)

    Science.gov (United States)

    Jensen, Lars Liengaard; Merrison, Jonathan; Hansen, Aviaja Anna; Mikkelsen, Karina Aarup; Kristoffersen, Tommy; Nørnberg, Per; Lomstein, Bente Aagaard; Finster, Kai

    2008-06-01

    We describe the design, construction, and pilot operation of a Mars simulation facility comprised of a cryogenic environmental chamber, an atmospheric gas analyzer, and a xenon/mercury discharge source for UV generation. The Mars Environmental Simulation Chamber (MESCH) consists of a double-walled cylindrical chamber. The double wall provides a cooling mantle through which liquid N2 can be circulated. A load-lock system that consists of a small pressure-exchange chamber, which can be evacuated, allows for the exchange of samples without changing the chamber environment. Fitted within the MESCH is a carousel, which holds up to 10 steel sample tubes. Rotation of the carousel is controlled by an external motor. Each sample in the carousel can be placed at any desired position. Environmental data, such as temperature, pressure, and UV exposure time, are computer logged and used in automated feedback mechanisms, enabling a wide variety of experiments that include time series. Tests of the simulation facility have successfully demonstrated its ability to produce temperature cycles and maintain low temperature (down to -140°C), low atmospheric pressure (5 10 mbar), and a gas composition like that of Mars during long-term experiments.

  7. Note: Fabrication of a fast-response and user-friendly environmental chamber for atomic force microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yanfeng; Hui, Fei; Shi, Yuanyuan; Han, Tingting; Song, Xiaoxue; Pan, Chengbin; Lanza, Mario, E-mail: mlanza@suda.edu.cn [Institute of Functional Nano & Soft Materials, Soochow University, Collaborative Innovation Center of Suzhou Nano Science & Technology, 199 Ren-Ai Road, Suzhou 215123 (China)

    2015-10-15

    The atomic force microscope is one of the most widespread tools in science, but many suppliers do not provide a competitive solution to make experiments in controlled atmospheres. Here, we provide a solution to this problem by fabricating a fast-response and user-friendly environmental chamber. We corroborate the correct functioning of the chamber by studying the formation of local anodic oxidation on a silicon sample (biased under opposite polarities), an effect that can be suppressed by measuring in a dry nitrogen atmosphere. The usefulness of this chamber goes beyond the example here presented, and it could be used in many other fields of science, including physics, mechanics, microelectronics, nanotechnology, medicine, and biology.

  8. Study on the Temperature Separation Phenomenon in a Vortex Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Ye, A Ran; Guang, Zhang; Kim, Heuy Dong [Andong National University, Andong (Korea, Republic of)

    2014-09-15

    A vortex chamber is a simple device that separates compressed gas into a high-temperature stream and a low-temperature stream. It is increasing in popularity as a next-generation heat exchanger, but the flow physics associated with it is not yet well understood. In the present study, both experimental and numerical analyses were performed to investigate the temperature separation phenomenon inside the vortex chamber. Static pressures and temperatures were measured using high-sensitivity pressure transducers and thermocouples, respectively. Computational fluid dynamics was applied to simulate 3D unsteady compressible flows. The simulation results showed that the temperature separation is strongly dependent on the diameter of the vortex chamber and the supply pressure at the inlet ports, where the latter is closely related to the viscous work. The previous concept of a pressure gradient wave may not be a reasoning for temperature separation phenomenon inside the vortex chamber.

  9. High vacuum general purpose scattering chamber for nuclear reaction study

    International Nuclear Information System (INIS)

    Suresh Kumar; Ojha, S.C.

    2003-01-01

    To study the nuclear reactions induced by beam from medium energy accelerators, one of the most common facility required is a scattering chamber. In the scattering chamber, projectile collides with the target nucleus and the scattered reaction products are detected with various type of nuclear detector at different angles with respect to the beam. The experiments are performed under high vacuum to minimize the background reaction and the energy losses of the charged particles. To make the chamber general purpose various requirement of the experiments are incorporated into it. Changing of targets, changing angle of various detectors while in vacuum are the most desired features. The other features like ascertaining the beam spot size and position on the target, minimizing the background counts by proper beam dump, accurate positioning of the detector as per plan etc. are some of the important requirements

  10. Environmental studies

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The utility of high-resolution liquid chromatography for separating organophosphorus compounds from natural waters and effluents from coal processing plants was investigated. The procedures were optimized for the separation of phenol-type compounds from aqueous effluents from coal liquefaction processes. Preliminary results are reported from applications for the analysis of marine waters from estuaries and municipal drinking water. An automated analytical system, using a bifurcated, fiber-optic fluorometer, was developed for the isolation and identification of trace polynuclear aromatic hydrocarbons for the continuous monitoring of coal liquefaction and coal gasification liquid effluents. The practice of chlorinating cooling waters was evaluated with respect to the formation of toxic chlorinated organic compounds of environmental importance

  11. Contribution to Diogene detector drift chambers study

    International Nuclear Information System (INIS)

    Drouet, M.

    1981-06-01

    Diogene detector has been brought into operation at Saclay with the collaboration of Strasbourg CRN and Clermont-Ferrand LPC. The Diogene essential characteristic is its solid angle near four pi, allowing complete exclusive measurements. Diogene characteristics allow to detect an important multiplicity of charged particles in coincidence, to measure their impulse until a transverse impulse around 1 GeV/c, and to identify them by their energy loss measurement. These general characteristics are exposed after some brief recalls on charged particle detection and migration counters. Technical aspects of the prototype are examined. It has been built to test fabrication technology, choice exactness and performance estimation validity. These detector performance estimation calculations that may be waited for in tracks reconstruction, impulse and energy loss resolution are exposed. Before, the electrostatics study for the prototype is reviewed. The temporary balance of already carried out tests is made [fr

  12. Study on a drift chamber for high energy experiments

    International Nuclear Information System (INIS)

    Puget, Maria Augusta Constante

    1993-01-01

    This work deals with the studies of a multiwire gaseous detector operating as a drift chamber, which will be part of the SELEX spectrometer of the experiment Fermilab E781. A prototype was designed to be built and tested at IFUSP. Results are shown of the analysis of data taken with another similar detector whose construction and test were done at Fermilab, with the aim of studying its characterization and performance. (author)

  13. The Mark III vertex chamber: Studies using DME

    International Nuclear Information System (INIS)

    Pitman, D.

    1987-04-01

    Studies have been performed using a prototype of a pressurized wire vertex chamber with 8 mm diameter straw geometry. A 35 μm spatial resolution using dimethyl ether (DME) at 1 bar and 30 μm using argon ethane (50/50 mixture) at 4 bar was obtained. Preliminary studies show the DME to adversely affect such materials as aluminized Mylar and Delrin

  14. Four Channel Mini Wire Chamber to Study Cosmic Rays

    Science.gov (United States)

    Felix, J.; Rodriguez, G. J.

    2018-01-01

    Multiwire proportional chamber is a conventional technique to study radiation in general, and cosmic rays in particular. To study cosmic rays, it was planned, designed, constructed, characterized, and tested a four channel mini wire chamber, based on two 3 cm × 3 cm × 0.6 cm Aluminum frames, two 3 cm × 3 cm × 0.6 cm plastic frames, two 3 cm × 3 cm × 0.3 cm Aluminum frames, two electronic planes each with two Tungsten Gold plated 1 mil diameter wires, parallel and 1 cm apart each other at 25 g stretched-each plane was 90° rotated each other in the final assemble- and two Aluminum foil window to define the gas volume; it was operated with Argon 90%-CH4 10% gas mixture at 1 atmosphere and ambient temperature (20°C in the average). It is presented technical details, results on characterization, and preliminary results on cosmic rays detection.

  15. High-repetition-rate hydrogen chamber: Preliminary studies

    International Nuclear Information System (INIS)

    1967-01-01

    This report is a conclusion to the tests realised with an experimental bubbles chamber in view to study the possibilities to increase the repetition rate. The more important parameters (the evolution of the bubbles, the expansion system) are considered in a theoretical way. Then the hardware is described. To end, experimental results are compared with the first evaluations. The calculations and the experimentation are against an oscillation system for the expansion. A system with a locking is to he considered. (authors) [fr

  16. Direct Measurements of Gas/Particle Partitioning and Mass Accommodation Coefficients in Environmental Chambers.

    Science.gov (United States)

    Krechmer, Jordan E; Day, Douglas A; Ziemann, Paul J; Jimenez, Jose L

    2017-10-17

    Secondary organic aerosols (SOA) are a major contributor to fine particulate mass and wield substantial influences on the Earth's climate and human health. Despite extensive research in recent years, many of the fundamental processes of SOA formation and evolution remain poorly understood. Most atmospheric aerosol models use gas/particle equilibrium partitioning theory as a default treatment of gas-aerosol transfer, despite questions about potentially large kinetic effects. We have conducted fundamental SOA formation experiments in a Teflon environmental chamber using a novel method. A simple chemical system produces a very fast burst of low-volatility gas-phase products, which are competitively taken up by liquid organic seed particles and Teflon chamber walls. Clear changes in the species time evolution with differing amounts of seed allow us to quantify the particle uptake processes. We reproduce gas- and aerosol-phase observations using a kinetic box model, from which we quantify the aerosol mass accommodation coefficient (α) as 0.7 on average, with values near unity especially for low volatility species. α appears to decrease as volatility increases. α has historically been a very difficult parameter to measure with reported values varying over 3 orders of magnitude. We use the experimentally constrained model to evaluate the correction factor (Φ) needed for chamber SOA mass yields due to losses of vapors to walls as a function of species volatility and particle condensational sink. Φ ranges from 1-4.

  17. Study on target interactions in emulsion chamber - Brasil-Japan emulsion chamber collaboration

    Science.gov (United States)

    Ballester, M.; Santos, C.; Bellandi Filho, J.; Chinellato, J. A.; Dobrigkeit, C.; Lattes, C. M. G.; Marques, A.; Menon, M. J.; Navia, C. E.; Sawayanagi, K.

    Experimental results are presented from observations of 80 target nuclear interactions where the total gamma-ray energy is greater than or equal to 20 TeV. Evidence is presented for the existence of two types of interactions; the interpretation is given on the basis of a fire-ball model. Two-story emulsion chambers exposed at Mount Chacaltaya, in Bolivia (5,220 m above sea level), are used. Gamma rays from nuclear interactions in the target layer of petroleum pitch (1/3 of the nuclear mean free path in thickness) are detected through observations of the electron showers generated by them in the lower chamber

  18. Technical Note: New methodology for measuring viscosities in small volumes characteristic of environmental chamber particle samples

    Directory of Open Access Journals (Sweden)

    L. Renbaum-Wolff

    2013-01-01

    Full Text Available Herein, a method for the determination of viscosities of small sample volumes is introduced, with important implications for the viscosity determination of particle samples from environmental chambers (used to simulate atmospheric conditions. The amount of sample needed is < 1 μl, and the technique is capable of determining viscosities (η ranging between 10−3 and 103 Pascal seconds (Pa s in samples that cover a range of chemical properties and with real-time relative humidity and temperature control; hence, the technique should be well-suited for determining the viscosities, under atmospherically relevant conditions, of particles collected from environmental chambers. In this technique, supermicron particles are first deposited on an inert hydrophobic substrate. Then, insoluble beads (~1 μm in diameter are embedded in the particles. Next, a flow of gas is introduced over the particles, which generates a shear stress on the particle surfaces. The sample responds to this shear stress by generating internal circulations, which are quantified with an optical microscope by monitoring the movement of the beads. The rate of internal circulation is shown to be a function of particle viscosity but independent of the particle material for a wide range of organic and organic-water samples. A calibration curve is constructed from the experimental data that relates the rate of internal circulation to particle viscosity, and this calibration curve is successfully used to predict viscosities in multicomponent organic mixtures.

  19. Silicon drift-chamber studies for possible use at RHIC

    International Nuclear Information System (INIS)

    Humanic, T.J.

    1990-01-01

    It is proposed to continue the program now underway at the University of Pittsburgh to study the feasibility of using silicon drift-chambers as particle tracking devices at RHIC. We are currently testing a UA6-type detector obtained from BNL and plan to also study a new device that will become available this year: a cylindrical geometry detector designed for NA45 (CERN). In addition we propose to fabricate and study a detector to be used in vertex determination for the RHIC OASIS experiment. The two-year budget for this proposal is $246.962. 5 refs., 12 figs

  20. Dosimetry, instrumentation and exposure chambers for dc magnetic field studies

    International Nuclear Information System (INIS)

    Tenforde, T.S.

    1979-03-01

    The principal objective of this report is to describe in detail an exposure chamber that was developed at the Lawrence Berkeley Laboratory for automated, noninvasive studies of rodent physiology during exposure to high DC magnetic fields. A second objective is to discuss some of the unique instrumentation problems that must be overcome in order to record bioelectric signals from laboratory animals in the presence of a magnetic field. Finally, a description will be given of the various dosimetry techniques that can be employed for quantitation of magnetic field strength

  1. Inspection of anode and field wires for the COMPASS drift chamber, DC5, with Environmental Scanning Electron Microscope

    Science.gov (United States)

    Cyuzuzo, Sonia

    2014-09-01

    The COMPASS experiment at CERN uses a secondary pion beam from the Super Proton Synchrotron (SPS) at CERN to explore the spin structure of nucleons. A new drift chamber, DC5, will be integrated into the COMPASS spectrometer to replace an aging straw tube detector. DC5 will detect muon pairs from Drell-Yan scattering of a pion-beam off a transversely polarized proton target. This data will be used to determine the correlation between transverse proton spin and the intrinsic transverse momentum of up-quarks inside the proton, the Sivers effect. DC5 is a large area planar drift chamber with 8 layers of anode-frames made of G10 fiberglass-epoxy. The G10 frames support printed circuit boards for soldering 20 μm diameter anode and 100 μm diameter field wires. The anode planes are sandwiched by 13 graphite coated Mylar cathode planes. To ensure a well-functioning of DC5, the wires were carefully tested. An optical inspection and a spectral analysis was performed with an Environmental Scanning Electron Microscope (ESEM) to verify the composition and dimensions and the integrity of the gold plating on the surface of these wires. The spectra of the wires were studied at 10 and 30 keV. The COMPASS experiment at CERN uses a secondary pion beam from the Super Proton Synchrotron (SPS) at CERN to explore the spin structure of nucleons. A new drift chamber, DC5, will be integrated into the COMPASS spectrometer to replace an aging straw tube detector. DC5 will detect muon pairs from Drell-Yan scattering of a pion-beam off a transversely polarized proton target. This data will be used to determine the correlation between transverse proton spin and the intrinsic transverse momentum of up-quarks inside the proton, the Sivers effect. DC5 is a large area planar drift chamber with 8 layers of anode-frames made of G10 fiberglass-epoxy. The G10 frames support printed circuit boards for soldering 20 μm diameter anode and 100 μm diameter field wires. The anode planes are sandwiched by 13

  2. Development of an environmental chamber for evaluating the performance of low-cost air quality sensors under controlled conditions

    Science.gov (United States)

    Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea

    2017-12-01

    A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.

  3. Study on the effect factor of the absolute fission rates measured by depleted uranium fission chamber

    International Nuclear Information System (INIS)

    Jiang Li; Liu Rong; Wang Dalun; Wang Mei; Lin Jufang; Wen Zhongwei

    2003-01-01

    The absolute fission rates was measured by the depleted uranium fission chamber. The efficiency of the fission fragments recorded in the fission chamber was analyzed. The factor influencing absolute fission rates was studied in the experiment, including the disturbing effect between detectors and the effect of the structural of the fission chamber, etc

  4. Silicon drift-chamber studies for possible use at RHIC

    International Nuclear Information System (INIS)

    Humanic, T.J.

    1990-01-01

    It is proposed to continue the program now underway at the University of Pittsburgh to study the feasibility of using silicon drift-chambers as particle tracking devices at RHIC. We are currently testing a UA6-type detector obtained from BNL, and propose to also study a new device that will become available this year: a cylindrical geometry detector design for NA45 (CERN). This new detector will be produced at BNL and the MPI-Institute in Munich and will incorporate updated techniques which should result in a reliable device with improved performance over the UA6-type detector. The one-year budget for this proposal is $50,079. 28 refs., 2 figs

  5. Environmental, economic and energy analysis of double glazing with a circulating water chamber in residential buildings

    International Nuclear Information System (INIS)

    Gil-Lopez, Tomas; Gimenez-Molina, Carmen

    2013-01-01

    Highlights: ► Glazed façade area is the part that produces greatest energy losses and gains. ► A potential for energy savings has been detected in residential buildings. ► Active glazing comprising two laminated glass panels with a circulating water chamber. ► Analysis of energy performance, economic viability and impact on carbon footprint. ► Natural gas condensing boilers is the less contaminating and more efficient option. -- Abstract: In general, the glazed façade area of a building is the part that produces the greatest energy losses and gains. The basic aim of this work is to achieve a more efficient heat control in closed spaces. To this end, an exhaustive study has been made of active glazing comprising two laminated glass panels with a circulating water chamber. Not only has the energy consumption been analysed but also the energy efficiency according to fuel type, the amount of CO 2 emitted into the atmosphere and the economic cost. The results of this study, from the points of view of economic feasibility and energy efficiency, show that the solution of double glazing with a circulating water chamber is a less polluting and more efficient option than the systems currently used. This solution is able to reduce the energy losses and gains that are produced through the glazed façade of a building by 18.26% for calorific and frigorific energy compared to the total consumption of the building. The layout of the proposed installation facilitates its integration into any type of residential building, either under construction or being renovated. Moreover, its zero visual impact means it can even be implemented in places with strict town-planning regulations.

  6. Review on Climate Control Chamber studies in studying plant environment interaction under climate change scenarios

    OpenAIRE

    Geethalakshmi, V.; Bhuvaneshwari, K.; Lakshmanan, A.

    2011-01-01

    This Technical brief summarizes some of the studies conducted on rice using a climate control chamber and outlines the studies that will be undertaken in the Climate Control Chamber facility that has been established at the Agro Climate Research Center at Tamil Nadu Agricultural University, Coimbatore. In recent years a numbers of technologies have been developed to study the impact of climate change on agricultural systems. Crop response to climate change could be studied by using a climate ...

  7. The Chamber for Studying Rice Response to Elevated Nighttime Temperature in Field

    Directory of Open Access Journals (Sweden)

    Song Chen

    2013-01-01

    Full Text Available An in situ temperature-controlled field chamber was developed for studying a large population of rice plant under different nighttime temperature treatments while maintaining conditions similar to those in the field during daytime. The system consists of a pipe hoop shed-type chamber with manually removable covers manipulated to provide a natural environment at daytime and a relatively stable and accurate temperature at night. Average air temperatures of 22.4 ± 0.3°C at setting of 22°C, 27.6 ± 0.4°C at 27°C, and 23.8 ± 0.7°C ambient conditions were maintained with the system. No significant horizontal and vertical differences in temperature were found and only slight changes in water temperatures were observed between the chambers and ambient conditions at 36 days after transplanting. A slight variation in CO2 concentration was observed at the end of the treatment during the day, but the 10-μmol CO2 mol−1 difference was too small to alter plant response. The present utilitarian system, which only utilizes an air conditioner/heater, is suitable for studying the effect of nighttime temperature on plant physiological responses with minimal perturbation of other environmental factors. At the same time, it will enable in situ screening of many rice genotypes.

  8. Study on time response properties of ionization chamber in profile gauge

    International Nuclear Information System (INIS)

    Wang Zhentao; Shen Yixiong; Wang Liqiang; Hao Pengfei

    2011-01-01

    The drift time of ions in the ionization chamber was measured by means of using a shortly pulsed X-ray device and through analyzing the voltage signals on the load resistor of the chamber recorded by a digital oscilloscope. By using this method, the time response properties of the ionization chamber in the profile gauge were studied, results of ion drift time for ionization chambers with different internal structures, different voltages and different gas pressures were introduced and the sources of error were discussed. The experiment results show that the time response of ionization chamber in profile gauge meets the requirement of on-line hot strip measuring. (authors)

  9. Self-contained high-pressure chambers for study on the Moessbauer effect at low temperatures

    International Nuclear Information System (INIS)

    Stepanov, G.N.

    1980-01-01

    Designs of two high-pressure chambers intended for studying the Moessbauer effect at low temperatures are described. The high-pressure chamber of the Bridgman anvil type is made of non magnetic materials and intended for operation at helium temperatures. The chamber employs a superconducting pressure gage. A sample and superconducting pressure gage are surrounded with a liquid medium of a high pressure at a room temperature. Measurements of the pressure were taken during heating the chamber in the vapours of liquid helium according to the known dependence of the lead superconducting transition temperature on pressure. The other high-pressure chamber of the piston-to-cylinder type can be used to study the Moessbauer effect at temperatures ranging from 4 to 300 K. Pressure in the chamber is measured by means of the superconducting pressure gage. The maximum pressure obtained in the chamber constitutes 25 kbar

  10. Inertial confinement fusion reaction chamber and power conversion system study. Final report

    International Nuclear Information System (INIS)

    Maya, I.; Schultz, K.R.; Bourque, R.F.

    1985-10-01

    This report summarizes the results of the second year of a two-year study on the design and evaluation of the Cascade concept as a commercial inertial confinement fusion (ICF) reactor. We developed a reactor design based on the Cascade reaction chamber concept that would be competitive in terms of both capital and operating costs, safe and environmentally acceptable in terms of hazard to the public, occupational exposure and radioactive waste production, and highly efficient. The Cascade reaction chamber is a double-cone-shaped rotating drum. The granulated solid blanket materials inside the rotating chamber are held against the walls by centrifugal force. The fusion energy is captured in a blanket of solid carbon, BeO, and LiAlO 2 granules. These granules are circulated to the primary side of a ceramic heat exchanger. Primary-side granule temperatures range from 1285 K at the LiAlO 2 granule heat exchanger outlet to 1600 K at the carbon granule heat exchanger inlet. The secondary side consists of a closed-cycle gas turbine power conversion system with helium working fluid, operating at 1300 K peak outlet temperature and achieving a thermal power conversion efficiency of 55%. The net plant efficiency is 49%. The reference design is a plant producing 1500 MW of D-T fusion power and delivering 815 MW of electrical power for sale to the utility grid. 88 refs., 44 figs., 47 tabs

  11. Oxford engineering students to study new solutions for vacuum chambers

    CERN Multimedia

    Department of Engineering Science - University of Oxford

    2012-01-01

    In April, eleven engineering science students in their third year at Oxford University were invited here to present their design ideas for new vacuum chamber materials to be used in accelerators. We publish below an abstract of the article that the University of Oxford featured on its website.   The 11 Oxford students who worked at CERN on alternatives to beryllium in vacuum chambers. (Photo courtesy of the Department of Engineering Science, University of Oxford.) Engineering Science students invited to design for CERN’s Large Hadron Collider In April, eleven Engineering Science students in their third year were invited to the CERN laboratory in Geneva to present their ideas for new vacuum chamber designs for the experiments of the Large Hadron Collider (LHC). Their design objectives were to propose alternatives to beryllium – the material used for some of the existing experimental vacuum chambers. Beryllium (chemical element with the symbol Be and atomic number 4) is to...

  12. A plant chamber system with downstream reaction chamber to study the effects of pollution on biogenic emissions.

    Science.gov (United States)

    Timkovsky, J; Gankema, P; Pierik, R; Holzinger, R

    2014-01-01

    A system of two plant chambers and a downstream reaction chamber has been set up to investigate the emission of biogenic volatile organic compounds (BVOCs) and possible effects of pollutants such as ozone. The system can be used to compare BVOC emissions from two sets of differently treated plants, or to study the photochemistry of real plant emissions under polluted conditions without exposing the plants to pollutants. The main analytical tool is a proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS) which allows online monitoring of biogenic emissions and chemical degradation products. The identification of BVOCs and their oxidation products is aided by cryogenic trapping and subsequent in situ gas chromatographic analysis.

  13. Establishment of a radon test chamber

    International Nuclear Information System (INIS)

    Chen Chingjiang; Liu Chichang; Lin Yuming

    1993-01-01

    A walk-in type radon test chamber of 23 m 3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)

  14. Environmental test chamber for the support of learning and teaching in intelligent control

    OpenAIRE

    Taylor, C. James

    2004-01-01

    The paper describes the utility of a low cost, 1 m2 by 2 m forced ventilation, micro-climate test chamber, for the support of research and teaching in mechatronics. Initially developed for the evaluation of a new ventilation rate controller, the fully instrumented chamber now provides numerous learning opportunities and individual projects for both undergraduate and postgraduate research students.

  15. Construction of a scattering chamber for ion-beam analysis of environmental materials in undergraduate physics research

    Energy Technology Data Exchange (ETDEWEB)

    LaBrake, Scott M.; Vineyard, Michael F.; Turley, Colin F.; Moore, Robert D.; Johnson, Christopher [Department of Physics and Astronomy Union College, Schenectady, NY 12308 (United States)

    2013-04-19

    We have developed a new scattering chamber for ion-beam analysis of environmental materials with the 1.1-MV Pelletron accelerator at the Union College Ion-Beam Analysis Laboratory. The chamber was constructed from a ten-inch, Conflat, multi-port cross and includes a three-axis target manipulator and target ladder assembly, an eight-inch turbo pump, an Amptek X-ray detector, and multiple charged particle detectors. Recent projects performed by our undergraduate research team include proton induced X-ray emission (PIXE) and Rutherford backscattering (RBS) analyses of atmospheric aerosols collected with a nine-stage cascade impactor in Upstate New York. We will describe the construction of the chamber and discuss the results of some commissioning experiments.

  16. Acid aerosol measurement method intercomparisons: An outdoor smog chamber study

    International Nuclear Information System (INIS)

    Ellestad, T.G.; Barnes, H.M.; Kamens, R.M.; McDow, S.R.; Sickles, J.E. II; Hodson, L.L.; Waldman, J.M.; Randtke, S.J.; Lane, D.D.; Springston, S.R.; Koutrakis, P.; Thurston, G.D.

    1991-01-01

    A workshop on the measurement of acid aerosols indicated that the sampling methods in use had not been intercompared. Following two laboratory pilot studies, EPA sponsored tests in an outdoor smog chamber with a variety of test aerosols, including sulfuric acid only, photochemical smog with added sulfuric acid, photo-chemical smog with added sulfuric acid and dust, and dust followed by photochemical smog with added sulfuric acid. Two experiments of each type were conducted. Six groups, several of which were active in ambient acid aerosol measurements, participated by operating duplicate samplers for each experiment. Five groups employed a similar method, in which ammonia is removed from the sample stream by diffusion, particles are removed by Teflon filter, and hydrogen ion on the Teflon filter is determined by pH electrode. However, differences existed in the method's implementation among groups in physical design, flow rate, procedures, and analysis. The sixth group's method did not use a diffusion denuder for ammonia and had several other important differences. Besides hydrogen ion, seven other species were reported by most of the groups, including particle phase sulfate, ammonium, and nitrate, and gas phase sulfur dioxide, ammonia, nitric acid, and nitrous acid. Results of the inter-comparison will be presented

  17. VUV photoemission studies of candidate LHC vacuum chamber materials

    CERN Document Server

    Baglin, V; Collins, I R

    1998-01-01

    In the context of future accelerators and, in particular, the beam vacuum of the LargeHadron Collider (LHC), a 27 km circumference proton collider to be built at CERN, VUVsynchrotron radiation (SR) has been used to study both qualitatively and quantitatively candidatevacuum chamber materials. Emphasis is given to show that angle and energy resolvedphotoemission is an extremely powerful tool to address important issues relevant to the LHC, suchas the emission of electrons that contribute to the creation of an electron cloud which may causeserious beam instabilities. Here we present not only the measured photoelectron yields (PY)from the proposed materials, prepared on an industrial scale, but also the energy and, in some cases,the angular dependence of the emitted electrons when excited with either a white light (WL)spectrum, simulating that in the arcs of the LHC or monochromatic light in the photon energy rangeof interest. The effects on the materials examined of WL irradiation and/or ion sputtering,simulati...

  18. Jabiluka environmental studies

    Energy Technology Data Exchange (ETDEWEB)

    Morley, A.W.; Koontz, D.V.; Sanderson, N.T. (Pancontinental Mining Ltd., Sydney (Australia))

    1984-02-01

    Environmental baseline studies associated with development of the Jabiluka uranium deposits are described. Some basic characteristics of the area local to the deposits are reported and a brief explanation is provided of the nature of, and philosophy behind the environmental studies. The major findings from this program are discussed.

  19. Jabiluka environmental studies

    International Nuclear Information System (INIS)

    Morley, A.W.; Koontz, D.V.; Sanderson, N.T.

    1984-01-01

    Environmental baseline studies associated with development of the Jabiluka uranium deposits are described. Some basic characteristics of the area local to the deposits are reported and a brief explanation is provided of the nature of, and philosophy behind the environmental studies. The major findings from this program are discussed. (author)

  20. Hypobaric chamber for the study of oral health problems in a simulated spacecraft environment

    Science.gov (United States)

    Brown, L. R.

    1974-01-01

    A hypobaric chamber was constructed to house two marmo-sets simultaneously in a space-simulated environment for periods of 14, 28 and 56 days which coincided with the anticipated Skylab missions. This report details the fabrication, operation, and performance of the chamber and very briefly reviews the scientific data from nine chamber trials involving 18 animals. The possible application of this model system to studies unrelated to oral health or space missions is discussed.

  1. Study on the ionization chamber for thickness measurement

    International Nuclear Information System (INIS)

    Xue Shili; Miao Qiangwen

    1988-01-01

    The principle, construction and performances of ionization chambers for measuring the thickness of metal and nonmetal materials are introduced. With them the thickness of thin materials (thickness ranging from 10 to 6000 g/m 2 ), the surface layer thickness of composed materials and the thickness of steel plate (thickness ranging from 0 to 32 kg/m 2 ) are measured effectively

  2. Study of energy dependence of a extrapolation chamber in low energy X-rays beams

    International Nuclear Information System (INIS)

    Bastos, Fernanda M.; Silva, Teogenes A. da

    2014-01-01

    This work was with the main objective to study the energy dependence of extrapolation chamber in low energy X-rays to determine the value of the uncertainty associated with the variation of the incident radiation energy in the measures in which it is used. For studying the dependence of energy, were conducted comparative ionization current measurements between the extrapolation chamber and two ionization chambers: a chamber mammography, RC6M model, Radcal with energy dependence less than 5% and a 2575 model radioprotection chamber NE Technology; both chambers have very thin windows, allowing its application in low power beams. Measurements were made at four different depths of 1.0 to 4.0 mm extrapolation chamber, 1.0 mm interval, for each reference radiation. The study showed that there is a variable energy dependence on the volume of the extrapolation chamber. In other analysis, it is concluded that the energy dependence of extrapolation chamber becomes smaller when using the slope of the ionization current versus depth for the different radiation reference; this shows that the extrapolation technique, used for the absorbed dose calculation, reduces the uncertainty associated with the influence of the response variation with energy radiation

  3. Black Carbon Aging from SOA Coatings and Coagulation with Diesel BC Emissions during SAAS at the PNNL Environmental Chamber

    Science.gov (United States)

    Aiken, A. C.; Liu, S.; Dubey, M. K.; Zaveri, R. A.; Shilling, J. E.; Gourihar, K.; Pekour, M. S.; Subramanian, R.; Zelenyuk, A.; Wilson, J. M.; Mazzoleni, C.; China, S.; Sharma, N.

    2014-12-01

    Black carbon (BC) is considered to be potentially the 2nd most important global warming factor behind CO2 (Bond et al., 2013). Uncertainties exist due to BC morphology and mixing state on the extent of the warming that it causes, e.g. Cappa et al., 2012. Core-shell BC is expected to enhance absorption by up to a factor of 2, but has yet to be observed to this extent from ambient data. Experiments were conducted during the Soot Aerosol Aging Study (SAAS) Laboratory Campaign at Pactific Northwest National Laboratory's Environmental Chamber in the winter of 2013-2014 to investigate the relationship between coatings and enhancements from diesel emissions. Direct on-line measurements were made with the single particle soot photometer (SP2) from fresh and aged BC from coating and coagulation experiments with secondary organic aerosol (SOA) formed in the chamber. BC measurements are coupled with photoactoustic measurements spanning the visible region to probe BC enhancements when mixed with SOA. Here we focus on the enhancements at 781 nm, that are tracked throughout SOA growth on BC, as determined from SP2 coating thicknesses. Thermal denuder (TD) experiments are conducted and enhancements are calculated from two different methods that agree well with each other, confirming the observed results. BC measurements are also compared with co-located measurements from SPLAT-II and filter analysis using SEM and TEM. BC coagulated with SOA produces minimal absorption enhancement values, whereas coatings are observed to have significant enhancement values at 300 degrees C, e.g. 1.3 for thickly coated BC. BC particles were coagulated with SOA in the chamber since this morphology has been observed in wildfire emissions (Sedlacek et al., 2012). Since we did not observe appreciable enhancements for the coagulated BC, we expect that ambient emissions dominated by this particle type to have enhancements due to other sources, such as brown carbon (BrC) that is often co-emitted (Saleh et

  4. Environmental pollution studies

    CERN Document Server

    Best, Gerry

    1999-01-01

    This book examines a number of important contemporary environmental issues in an informative and easy-to-read style. The topics covered include sewage treatment, eutrophication, air pollution, acid rain, global warming and pollution from farming. A particularly valuable section of the book describes a range of tests that can be carried out on various environmental parameters. The procedures require relatively simple equipment and they have been pre-tested in a school laboratory. "Environmental Pollution Studies" will be of value to senior school pupils and students at college or university embarking on courses in environmental science.

  5. Monte Carlo studies on Cathode Strip/Pad Chambers for the ALICE Di-Muon Arm

    Energy Technology Data Exchange (ETDEWEB)

    Wurzinger, R.; Le Bornec, Y.; Willis, N.

    1996-04-01

    A general overview about the properties of Cathode Strip and Pad Chambers is given. Position finding methods are discussed and compared within Monte Carlo studies. Noise contributions and their minimization are discussed. Pad chambers allow a two-dimensional readout with spatial resolution of {sigma} < 100 {mu}m in direction parallel to the anode wire. The resolution normal to the anode wire depends mainly on the wire spacing. Special attention is paid on the double-hit resolution capability of the pad chamber. An outlook is given on the possible utilisation of Cathode Pad Chambers in the Di-Muon Arm of the ALICE detector at LHC. (author). 44 refs.

  6. Building Transdisciplinary Environmental Studies

    DEFF Research Database (Denmark)

    Holm, Jesper

    We will in this paper approach the challenge of building integrated environmental studies by presenting a crude frame of analysis which take into account both the physical aspects and the social-discursive articulations of environmental problems. This framework partly mirrors the approach of our...... department (Dept. of Environment, Technology and Social Studies, Roskilde University), and has originally in another version been presented in the book “Miljøregulering - tværvidenskabelige studier (Environmental Regulation. Interdisciplinary Studies)” (Holm, Kjærgård & Pedersen eds. 1997, in Danish) written...

  7. Study of an avalanche-mode resistive plate chamber

    International Nuclear Information System (INIS)

    Ying, J.; Ban, Y.; Liu, H.T.; Zhu, Z.M.; Zhu, Z.Y.; Chen, T.; Ma, J.G.; Ye, Y.L.

    2000-01-01

    Resistive plate chambers (RPCs) are widely used to detect high-energy charged particles, especially muons, due to the high gain, moderate time and spatial resolution, simple design and low cost of these detectors. While the simple streamer mode is adequate for cosmic-ray and low-rate accelerator experiments, the avalanche mode is required for high-rate experiments such as CMS at LHC. In this paper construction of a medium-sized double-gap RPC made of Chinese materials is reported. The experimental set-up of cosmic-ray and muon beam tests are introduced. The avalanche mode was clearly observed. Good efficiency and time resolution were obtained from the beam test at CERN under normal irradiation conditions. At very high radiation background the chamber efficiency decreases, indicating the necessity to change the resistivity value of the Chinese bakelites. (author)

  8. study on trace contaminants control assembly for sealed environment chamber

    Science.gov (United States)

    Pang, L. P.; Wang, J.; Liu, L. K.; Liu, H.

    The biological and Physicochemical P C life support technologies are all important parts to establish a human Closed Ecological Life Support System CELSS for long-duration mission The latter has the advantages of lower power consumption lower mass and higher efficiency therefore researchers often incorporate the use of biological systems with P C life support technologies to continuously recycle air water and part of the solid waste stream generated such as the Russian BLSS and the NASA-sponsored Lunar-Mars Life Support Test Project LMLSTP In short these tests were very successful in integrating biological and P C life support technologies for long-duration life support Therefore we should use a combination of integrated biological with P C life support technologies in a human CELSS Human construction materials plants animals and soils release much trace toxic gases in a CELSS and they will inhibit plant growth and badly affect human health when their concentrations rise over their threshold levels The effect of biological trace contaminant control technologies is slower especially for a human sealed chamber because human produce much more methane and other contaminants A regenerative Trace Contaminant Control Subsystem TCCS with P C technology is a more important part in this case to control quickly the airborne contaminants levels and assure human in good condition in a sealed chamber This paper describes a trace contaminant control test facility incorporated a 8 m3 sealed environment chamber a regenerative TCCS with P C

  9. Studies of particle interactions in bubble chamber, spark chambers and counter experiments. Annual progress report

    International Nuclear Information System (INIS)

    Holloway, L.E.; O'Halloran, T.A. Jr.; Simmons, R.O.

    1983-07-01

    During the past six years we have carried out and planned experiments which predominantly studied the production and decay of particles containing charmed quarks. A series of photoproduction and neutron production experiments started with the very early observation of the production of J/psi by neutrons and by photons at Fermilab. From subsequent experiments using these neutral beams and the basic detecting system, we have reported results on the photoproduction of the Λ/sub c/ charmed baryon and the D and D* charmed mesons. More recent runs are studying the high energy photoproduction of vector mesons including the psi'. The present experiment in this sequence is using neutrons to produce a large number of D mesons. Another series of experiments at Fermilab set out to study the hadronic production of charmed mesons. The Chicago Cyclotron facility was modified with a detector sensitive to various possible production mechanisms. The experiments were a success; clean signals of D mesons were observed to be produced by pions, and also the production of chi/sub c/ with the subsequent decay via a γ-ray to psi was observed. The charmonium experiments run this year have better photon resolution for measuring the decays of chi/sub c/ to psi. We are part of a collaboration which is working on the Collider Detector Facility for Fermilab. The CDF at Fermilab is a possible source of (weak) intermediate vector bosons from the collisions of protons and anti-protons. Our responsibilities in the CDF include both the construction of the muon detector and the designing, planning, and testing of the FASTBUS electronics. The second part of our weak interaction program is the Neutrino Oscillation experiment which is now under construction at Brookhaven

  10. Performance, operation and detector studies with the ATLAS Resistive Plate Chambers

    International Nuclear Information System (INIS)

    Aielli, G; Bindi, M; Polini, A

    2013-01-01

    Resistive Plate Chambers provide the barrel region of the ATLAS detector with an independent muon trigger and a two-coordinate measurement. The chambers, arranged in three concentric double layers, are operated in a strong magnetic toroidal field and cover a surface area of about 4000 m 2 . During 2011 the LHC has provided proton-proton collisions at 7 TeV in the center-of-mass frame with a steady increase in instantaneous luminosity, summing up to about 5 fb −1 . The operational experience for this running period is presented along with studies of the detector performance as a function of luminosity, environmental conditions and working point settings. Non-event based information including in particular the large number of gas gap currents, individually monitored with nA accuracy, have been used to study the detector behavior with growing luminosity and beam currents. These data are shown to provide, when calibrated, an independent luminosity measurement and a crucial handle for understanding the ATLAS backgrounds well beyond the scope of muon triggering and detection. The measurements presented here allow to plan a strategy for the data taking in the next years and make some predictions about the detector performance at higher luminosities. They also improve the knowledge on RPC detector physics.

  11. Thermal studies on a mechanical prototype of A BIS MDT chamber

    CERN Document Server

    Petridou, C; Wotschack, J; Zisis, A

    1998-01-01

    The deformations of a BIS MDT chamber owing to temperature gradients between the two multilayers and between the two Faraday cages were studied on a mechanical prototype. The influence of thermal insulation on the thermal behaviour of the chamber is also reported.

  12. Transmutation and neutron flux studies with fission chambers in the MEGAPIE target

    International Nuclear Information System (INIS)

    Chabod, S.; Foucher, Y.; Letourneau, A.; Marie, F.; Toussaint, J.C.; Blandin, Ch.; Chartier, F.; Fioni, G.

    2005-01-01

    Eight fission micro chambers will be inserted inside the central rod of the 1 MW liquid Pb-Bi MEGAPIE target in order to study the transmutation of two major actinides and to measure the neutron flux at a level of 5%. These chambers were developed for high neutron fluxes and tested at Laue Langevin Institute. (authors)

  13. Study on superhigh energy γ-ray family events with large-scale Fe emulsion chambers

    International Nuclear Information System (INIS)

    Ren Jingru; Lu Suiling; Su Shi

    1990-01-01

    Using a large-scale iron emulsion chamber, a big γ-ray family event with observed energy ΣE r = 7631 TeV was obtained. This paper described the advantages of iron emulsion chamber for studying big families and the characteristics of the event observed, together with a comparison with the Monte-Carlo simulation results

  14. Simulation studies on a prototype ionization chamber for measurement of personal dose equivalent, Hp(10)

    International Nuclear Information System (INIS)

    Cardoso, J.; Oliveira, C.; Carvalho, A.F.

    2005-01-01

    Full text: The Metrological Laboratory of lonizing Radiation and Radioactivity (LMRIR) of Nuclear and Technological Institute (ITN) has designed and constructed a prototype ionization chamber for direct measurement of the personal dose equivalent, H p (10), similar to the developed by the Physikalisch-Technische Bundesanstalt (PTB) and now commercialized by PTW. Tests already performed had shown that the behaviour of this chamber is very close to the PTB chamber, namely the energy dependence for the x-ray radiation qualities of the ISO 4037-1 narrow series N-30, N-40, N-60, N-80, N-100 and N-120 and also for gamma radiation of 137 Cs and 60 Co. However, the results obtained also show a high dependence on the energy for some incident radiation angles and a low magnitude of the electrical response of the ionization chamber. In order to try to optimize the performance of the chamber, namely to decrease the energy dependence and to improve the magnitude of the electrical response of the ionization chamber, the LMRIR initiated numerical simulation of this ionization chamber using a Monte-Carlo method for simulation of radiation transport using, in a first step, the MCNPX code. So, simulation studies of some physical parameters are been performed in order to optimize the response of the ionization chamber, namely the diameter of the central electrode of the ionization chamber, the thickness of the front wall of the ionization chamber, among others. Preliminary results show that probably the actual geometry of the ionization chamber is not yet the optimized configuration. The simulation study will carry on in order to find the optimum geometry. (author)

  15. Potentiality of low cost environmentally friendly chamber for storage of irradiated potato and onion

    International Nuclear Information System (INIS)

    Roy, S.K.; Chakrabarti, A.K.; Pal, R.K.

    1994-01-01

    Potatoes and onions are two important horticultural commodities in India. Refrigeration is an expensive system and it is beyond the means of the poor, small and marginal farmers. Based on the principle of direct evaporative cooling, the scientists of the Indian Agricultural Research Institute developed a zero energy cool chamber. The zero energy cool chamber was tried at different locations in the country and was found to be very effective in increasing the shelf life of the fruits and vegetables and decreasing the physiological loss in weight

  16. Alfalfa seedlings grown outdoors are more resistant to UV-induced DNA damage than plants grown in a UV-free environmental chamber

    International Nuclear Information System (INIS)

    Takayanagi, Shinnosuke; Trunk, J.G.; Sutherland, J.C.; Sutherland, B.M.

    1994-01-01

    The relative UV sensitivities of alfalfa seedlings grown outdoors versus plants grown in a growth chamber under UV-filtered cool white fluorescent bulbs have been determined using three criteria: (1) level of endogenous DNA damage as sites for the UV endonuclease from Micrococcus luteus, (2) susceptibility to pyrimidine dimer induction by a UV challenge exposure and (3) ability to repair UV-induced damage. We find that outdoor-grown plants contain approximately equal frequencies of endogenous DNA damages, are less susceptible to dimer induction by a challenge exposure of broad-spectrum UV and photorepair dimers more rapidly than plants grown in an environmental chamber under cool white fluorescent lamps plus a filter removes most UV radiation. These data suggest that plants grown in a natural environment would be less sensitive to UVB-induced damage than would be predicted on the basis of studies on plants grown under minimum UV. (author)

  17. Scattering study at free air ionization chamber diaphragm

    International Nuclear Information System (INIS)

    Santos, Alexandre Lo Bianco dos

    2011-01-01

    The maim of this work consisted in the assessment of the correction factor for air kerma, due to scattered radiation in the diaphragm of the free-air ionization chamber model 481. LNMRl measurements were made to acquire x-ray spectra corresponding to the Qualities RQR-M, described in IEC 61627 standards (2005). These spectra were used as input data in the MC simulations. The operational range of energy spectra provide up to 35 keV. This energy range is typically used in diagnostic radiology, although there is not primary standard for air kerma. The determination of this factor is a fundamental process in the primary standardization of the air kerma. These factors were obtained by computer simulation using the Penelope code. The results are k RQR-M1 =0,9946, k RQR -M2 =0,9932, k RQR-M3 =0,9978 and k RQR-M4 =0,9885; with uncertainties of 0,007 and coverage factor equal to 2. lt can be concluded that, with respect to the diaphragm, the chamber can be used in the primary standard of air kerma. (author)

  18. Study of straw chamber lifetime with argon ethane

    International Nuclear Information System (INIS)

    Adler, J.; Bolton, T.; Bunnell, K.; Cheu, E.; Grab, C.; Mazaheri, G.; Odian, A.; Pitman, D.; Stockhausen, W.; Toki, W.; Wadley, W.; Wood, C.; Mir, R.

    1989-01-01

    We present detailed laboratory measurements of the lifetime of a small test chamber, simulating the Mark III straw vertex chamber conditions. The tests were carried out with an argon-ethane 50/50 gas mixture at 3 atm absolute pressure and 3.9 kV applied to the wires. After the accumulation of ≅ 0.02 C/cm on a single straw, continuous discharges began. The addition of alcohol or water vapor to the gas mixture was found to extend the lifetime of the straws. Continuous flow of the gas mixture with water vapor through the straws prolonged the lifetime significantly. We present results on the effects of changing the gas mixture inside the straws at regular time intervals. Adding a small percentage of water vapor to the argon-ethane gas and flowing the gas mixture in the straws can improve the lifetime by more than an order of magnitude. An accumulated charge of 1.0 C/cm on a single straw has been obtained. (orig.)

  19. A plant chamber system with downstream reaction chamber to study the effects of pollution on biogenic emissions

    NARCIS (Netherlands)

    Timovsky, J.; Gankema, Paulien; Pierik, Ronald; Holzinger, Rupert

    2014-01-01

    A system of two plant chambers and a downstream reaction chamber has been set up to investigate the emission of biogenic volatile organic compounds (BVOCs) and possible effects of pollutants such as ozone. The system can be used to compare BVOC emissions from two sets of differently treated plants,

  20. Drift chamber

    International Nuclear Information System (INIS)

    Inagaki, Yosuke

    1977-01-01

    Drift chamber is becoming an important detector in high energy physics as a precision and fast position detector because of its high spatial resolution and count-rate. The basic principle is that it utilizes the drift at constant speed of electrons ionized along the tracks of charged particles towards the anode wire in the nearly uniform electric field. The method of measuring drift time includes the analog and digital ones. This report describes about the construction of and the application of electric field to the drift chamber, mathematical analysis on the electric field and equipotential curve, derivation of spatial resolution and the factor for its determination, and selection of gas to be used. The performance test of the chamber was carried out using a small test chamber, the collimated β source of Sr-90, and 500 MeV/C electron beam from the 1.3 GeV electron synchrotron in the Institute of Nuclear Study, University of Tokyo. Most chambers to date adopted one dimensional read-out, but it is very advantageous if the two dimensional read-out is feasible with one chamber when the resolution in that direction is low. The typical methods of delay line and charge division for two dimensional read-out are described. The development of digital read-out system is underway, which can process the signal of a large scale drift chamber at high speed. (Wakatsuki, Y.)

  1. Wire chamber requirements and tracking simulation studies for tracking systems at the superconducting super collider

    International Nuclear Information System (INIS)

    Hanson, G.G.; Niczyporuk, B.B.; Palounek, A.P.T.

    1989-02-01

    Limitations placed on wire chambers by radiation damage and rate requirements in the SSC environment are reviewed. Possible conceptual designs for wire chamber tracking systems which meet these requirements are discussed. Computer simulation studies of tracking in such systems are presented. Simulations of events from interesting physics at the SSC, including hits from minimum bias background events, are examined. Results of some preliminary pattern recognition studies are given. Such computer simulation studies are necessary to determine the feasibility of wire chamber tracking systems for complex events in a high-rate environment such as the SSC. 11 refs., 9 figs., 1 tab

  2. Silicon drift chamber studies for the RHIC STAR experiment

    International Nuclear Information System (INIS)

    Humanic, T.J.

    1992-01-01

    The two-hit resolution of a silicon drift chamber is measured using a pulsed Nd:Yag laser and a time digitizer readout. The data is analyzed by forming the covariance matrix in time samples, and transforming to a matrix in amplitude and time variation of each of the two hits. The resolution of the two-hit separation is found to be better than 25 microns with a drift field of 530 V/cm and a separation of more than 500 microns, with the resolution increasing to 50 microns as the separation nears 500 microns. Results are also presented for multiply ionizing tracks, showing a great improvement over single minimum ionizing. 8 refs

  3. Study of plasma in MAGO chamber by own neutron radiation

    International Nuclear Information System (INIS)

    Burenkov, O.M.; Garanin, S.F.; Demin, A.N.; Dudin, I.F.; Korchagin, V.P.; Morozov, I.V.; Mokhov, V.N.; Pavlovskij, E.S.; Chernyshev, V.K.; Yakubov, V.B.

    1996-01-01

    The measured ratio of the DD and DT reaction rates is used for determining the ion temperature in the MAGO hot plasma chamber driven by explosive magnetic generator. The method exploits the differences in the temperature dependence of the DD and DT reaction rates. The reaction rates are estimated from the DD and DT neutron spectra measured by the time-of flight method. In the paper the MAGO experimental arrangement is described in detail, and the problems arising at interpretation of the somewhat contradictory results of neutron diagnostics are discussed. A reasonable value of the ion temperature (5.5 keV maximum) can be obtained when assuming a strong anisotropy of the ion distribution. In order to verify the reported results further more detailed neutron diagnostic experiments are planned. (J.U.). 7 figs., 6 refs

  4. Study of plasma in MAGO chamber by own neutron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Burenkov, O M; Garanin, S F; Demin, A N; Dudin, I F; Korchagin, V P; Morozov, I V; Mokhov, V N; Pavlovskij, E S; Chernyshev, V K; Yakubov, V B [All-Russian Scientific Research Institute of Experimental Physics, Arzamas (Russian Federation)

    1997-12-31

    The measured ratio of the DD and DT reaction rates is used for determining the ion temperature in the MAGO hot plasma chamber driven by explosive magnetic generator. The method exploits the differences in the temperature dependence of the DD and DT reaction rates. The reaction rates are estimated from the DD and DT neutron spectra measured by the time-of flight method. In the paper the MAGO experimental arrangement is described in detail, and the problems arising at interpretation of the somewhat contradictory results of neutron diagnostics are discussed. A reasonable value of the ion temperature (5.5 keV maximum) can be obtained when assuming a strong anisotropy of the ion distribution. In order to verify the reported results further more detailed neutron diagnostic experiments are planned. (J.U.). 7 figs., 6 refs.

  5. Study of an extrapolation chamber in a standard diagnostic radiology beam by Monte Carlo simulation

    International Nuclear Information System (INIS)

    Vedovato, Uly Pita; Silva, Rayre Janaina Vieira; Neves, Lucio Pereira; Santos, William S.; Perini, Ana Paula; Belinato, Walmir

    2016-01-01

    In this work, we studied the influence of the components of an extrapolation ionization chamber in its response. This study was undertaken using the MCNP-5 Monte Carlo code, and the standard diagnostic radiology quality for direct beams (RQR5). Using tally F6 and 2.1 x 10"9 simulated histories, the results showed that the chamber design and material not alter significantly the energy deposited in its sensitive volume. The collecting electrode and support board were the components with more influence on the chamber response. (author)

  6. Study of the replacement correction factors for ionization chamber dosimetry by Monte Carlo simulations

    Science.gov (United States)

    Wang, Lilie

    In ionization chamber radiation dosimetry, the introduction of the ion chamber into medium will unavoidably distort the radiation field near the chamber because the chamber cavity material (air) is different from the medium. A replacement correction factor, Prepl was introduced in order to correct the chamber readings to give an accurate radiation dose in the medium without the presence of the chamber. Generally it is very hard to measure the values of Prepl since they are intertwined with the chamber wall effect. In addition, the P repl values always come together with the stopping-power ratio of the two media involved. This makes the problem of determining the P repl values even more complicated. Monte Carlo simulation is an ideal method to investigate the replacement correction factors. In this study, four different methods of calculating the values of Prepl by Monte Carlo simulation are discussed. Two of the methods are designated as 'direct' methods in the sense that the evaluation of the stopping-power ratio is not necessary. The systematic uncertainties of the two direct methods are estimated to be about 0.1-0.2% which comes from the ambiguous definition of the energy cutoff Delta used in the Spencer-Attix cavity theory. The two direct methods are used to calculate the values of P repl for both plane-parallel chambers and cylindrical thimble chambers in either electron beams or photon beams. The calculation results are compared to measurements. For electron beams, good agreements are obtained. For thimble chambers in photon beams, significant discrepancies are observed between calculations and measurements. The experiments are thus investigated and the procedures are simulated by the Monte Carlo method. It is found that the interpretation of the measured data as the replacement correction factors in dosimetry protocols are not correct. In applying the calculation to the BIPM graphite chamber in a 60Co beam, the calculated values of P repl differ from those

  7. DORIOT CLIMATIC CHAMBERS

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers reproduce environmental conditions occurring anywhere around the world. They provide an invaluable service by significantly reducing the...

  8. A system for the study of molecular contamination. [experimental vacuum chambers

    Science.gov (United States)

    Dillow, C. F.; Allen, T. H.; Linford, R. M. F.; Richmond, R. G.

    1975-01-01

    An experimental vacuum chambers was designed and fabricated to provide a wide range of experimental capability. This work chamber assembly (WCA) was conceived to establish the proof-of-principle of various techniques for studying the kinetics of contaminants and their effects. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation.

  9. Punta Higuero environmental studies

    International Nuclear Information System (INIS)

    Wood, E.D.; Youngbluth, M.J.; Nutt, M.E.; Yeaman, M.N.; Yoshioka, P.; Canoy, M.J.

    1975-01-01

    Site selection surveys and environmental research studies of seven coastal sites in Puerto Rico for construction of power generating facilities were carried out. Data are presented on the physical, chemical, and geological parameters of the Punta Higuero site, and the ecological parameters of zooplankton, benthic invertebrates, and fish communities. Plant associations are included. (U.S.)

  10. Study of a bubble chamber's pictures automatic analyser: Coccinelle

    International Nuclear Information System (INIS)

    Jaeger, J.-J.

    1974-01-01

    The automatic scanning and measuring system ''Coccinelle'' built in the Laboratoire de Physique Corpusculaire of College de France, is specially made for the pictures of the new large bubble chambers like BEBC and Mirabelle. This device uses the spot of a high precision cathode ray tube for the analysis of the picture according to a scanning window. The signal of a photomultiplier located behind the picture gives, after processing, the useful information in the form of coordinates of the analyzed points. Electronics, connected to a computer, generates the movements of the spot, the backward and forward movement of the films, and gives the right information for the programs of geometrical reconstruction of the tracks. The use of the device is based upon the collaboration of a programmed automaton and a human operator that have conversational facilities: TV display, light-pen and function keyboard. Beyond a detailed description of the whole device, this thesis insists especially on the following electronic parts: sweep generation of the spot, photomultiplier signal processing [fr

  11. A study on models of the inhomogeneity of the decompression in a bubble chamber

    International Nuclear Information System (INIS)

    Badier, J.

    1961-01-01

    Before building a hydrogen bubble chamber with liquid decompression the 'Saturne' cyclotron department wished to study for this chamber a shape leading to a homogeneous decompression as far as possible, without the production of vortices even after prolonged operation. The 'Office National d'Etudes et de Recherches Aeronautiques' (ONERA) were ready to carry out experiments on a model by strioscopy. The model was filled with air but an attempt was made to simulate the actual conditions as far as possible by varying the speed of the piston. The model was placed at one end of a tunnel, at the other end of which were produced alternatively compression and decompression waves. The study made it possible to conclude that it was necessary to make the base of the chamber round and that, in the space between the decompression cylinder and the body of the chamber it was advantageous to use 5 fins instead of 3. (author) [fr

  12. Glove box chamber

    International Nuclear Information System (INIS)

    Cox, M.E.; Cox, M.E.

    1975-01-01

    An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)

  13. Measurements of VOC/SVOC emission factors from burning incenses in an environmental test chamber: influence of temperature, relative humidity, and air exchange rate.

    Science.gov (United States)

    Manoukian, A; Buiron, D; Temime-Roussel, B; Wortham, H; Quivet, E

    2016-04-01

    This study investigates the influence of three environmental indoor parameters (i.e., temperature, relative humidity, and air exchange rate) on the emission of 13 volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) during incense burning. Experiments have been carried out using an environmental test chamber. Statistical results from a classical two-level full factorial design highlight the predominant effect of ventilation on emission factors. The higher the ventilation, the higher the emission factor. Moreover, thanks to these results, an estimation of the concentration range for the compounds under study can be calculated and allows a quick look of indoor pollution induced by incense combustion. Carcinogenic substances (i.e., benzene, benzo(a)pyrene, and formaldehyde) produced from the incense combustion would be predicted in typical living indoors conditions to reach instantaneous concentration levels close to or higher than air quality exposure threshold values.

  14. Alpha spectroscopy with ionization chamber to determine uranium and thorium in environmental samples

    International Nuclear Information System (INIS)

    Carvalho Conti, L.F. de.

    1983-01-01

    A high-resolution, parallel Frisch ionization chamber with an efficient area of 320 cm 2 was developed and applied as an alpha spectrometer. The resolution of the spectrum is approximatelly 40 KeV fwhm (full width half maximum) for 233 U point source. The spectrum is recorded by a 1024 channels pulse-height analyser. The counting gas is commercial available mixture of argon and methane. The counting efficiency for 233 U energy-window selected is in order of 42% for a calibration source placed on the cathode axis. No radial dependence of this efficiency was observed. The chamber was used for counting the activity of uranium and thorium isotopes on large area stainless steel planchets. The large area thin sources were prepared extracting the uranium and thorium isotopes from 1M HNO 3 - aqueous solution with polymeric membranes containing tri-n-octyl-phosphine oxide adhered on the surface of the 314 cm 2 planchet. The integral back-ground is typically 7 counts/min between 4 and 6 MeV. The sensitivity of the procedure used ofr 238 U is about 30 Bq/1 based on 3S of back-ground, 1 liter sample volume and 30 min counting time. (Author) [pt

  15. RGA studies on aluminium chambers for transport line-2 of CLIC facility at CERN

    International Nuclear Information System (INIS)

    Kumar, K.V.A.N.P.S.; Yadav, Praveen Kumar; Sindal, B.K.; Tiwari, S.K.; Tripti, B.; Shukla, S.K.

    2009-01-01

    The Aluminium Chambers for Transport Line-2 (TL-2) of CLIC (Compact Linear Collider) facility were developed by RRCAT, Indore under the CERN-DAE collaboration work. The ultimate vacuum required for these chambers is in 10 -10 mbar range. The design and fabrication of the chambers were done at Workshop-A, RRCAT, Indore. Ultra High Vacuum (UHV) Section at RRCAT, Indore was involved in qualifying tests of these chambers for their ultimate vacuum testing and the residual gas spectrum studies as per CERN requirements. The UHV testing part was established and the RGA studies were conducted using Residual Gas Analyser (RGA, 1-100 AMU range, Make: Spectra/MKS, USA). The RGAs were used for vacuum diagnostics like checking for leaks and the vacuum quality in the chambers. Using the RGA, we could also observe out the pumping speed behaviour of a UHV Gauge (Varian UHV-24 type) and the retention-cum-evaluation of captured gases by Sputter Ion Pump was also studied. In this paper, these experiences are reported during ultimate testing of TL-2 chambers for CLIC facility. (author)

  16. Ozone and Botrytis interactions in onion-leaf dieback: open-top chamber studies

    Energy Technology Data Exchange (ETDEWEB)

    Wukasch, R.T.; Hofstra, G.

    1977-09-01

    Paired open-top chambers were used to study interactions between Botrytis spp. and ozone in field-grown onions. Charcoal filters removed 35 to 65% of the ambient ozone, resulting in six-fold reduction of onion leaf dieback and a 28% increase in onion yield compared with unfiltered chambers. Symptoms of leaf injury appeared soon after ozone levels exceeded 294 ..mu..g/m/sup 3/ (0.15 ppm) for 4 hr. Lesions caused by Botrytis were few because no dew formed in the chambers. However, when leaves were wetted with foggers, inoculation with mycelial suspensions of B. sauamosa in late August produced significantly more lesions and leaf dieback in the unfiltered chamber. Botrytis squamosa, B. cinerea, B. allii, and several genera of secondary fungi were isolated from these lesions. Botrytis squamosa was recovered from lesions only, whereas B. cinerea and B. allii were associated more generally with onion leaf tissue regardless of lesions. 25 references, 1 figure, 2 tables.

  17. An experimental setup for the study of the steady air flow in a diesel engine chamber

    Directory of Open Access Journals (Sweden)

    Montanero José María

    2012-04-01

    Full Text Available We present an experimental setup for studying the steady air flow in a diesel engine chamber. An engine block containing the inlet manifold was placed on a test bench. A steady air stream crossed the inlet manifold and entered a glass chamber driven by a fan. A PIV system was set up around the bench to measure the in-chamber flow. An air spray gun was used as seed generator to producing sub-millimeter droplets, easily dragged by the air stream. Images of the in-flow chamber were acquired in the course of the experiments, and processed to measure the velocity field. The pressure drop driven the air current and the mass flow rate were also measured.

  18. Measurement of radioactive gases. Study of SACM type CD2 differential chamber

    International Nuclear Information System (INIS)

    Benezech, G.

    1963-01-01

    This study aims at precising practical conditions of use of a circulation chamber to measure the activity of beta- and gamma-emitting radioactive gases. Results more particularly concern the SACM type CD 2 differential chamber but can easily be adapted to any other chamber type. Calibration calculations allow the definition of the field of use of this chamber. It appears that this apparatus will not generally allow a fine dosimetry of radioactive gases as the method is not selective and requires the knowledge of the gas nature. The author presents the operation principle, describes the experimental assembly, and discusses its performance in the case of a linear assembly and of a logarithmic assembly. He reports the calibration process and calculations (calculation of the ionization current with respect to gas activity, experimental measurement of this ionization current with respect to activity) [fr

  19. Studies of Helium Based Gas Mixtures Using a Small Cell Drift Chamber

    International Nuclear Information System (INIS)

    Heise, Jaret; British Columbia U.

    2006-01-01

    An international collaboration is currently working on the construction and design of an asymmetric B Factory at the Stanford Linear Accelerator Center that will be ready to collect data in 1999. The main physics motivation for such a facility is to test the description and mechanism of CP violation in the Standard Model of particle physics and provide insight into the question of why more matter than antimatter is observed in the universe today. In particular, this experiment will measure CP violation in the decay of B mesons. In the early stages of this effort, the Canadian contingent proposed to build the central tracking chamber for the BABAR detector. Presently, a prototype drift chamber is in operation and studies are being performed to test some of the unique features of drift chamber design dictated by the conditions of the experiment. Using cosmic muons, it is possible to study tracking and pattern recognition in the prototype chamber, and therefore calculate the efficiency and spatial resolution of the prototype chamber cells. These performance features will be used to test whether or not the helium-based gas mixtures proposed for the BABAR drift chamber are a viable alternative to the more traditional argon-based gases

  20. A pressurized ion chamber monitoring system for environmental radiation measurements utilizing a wide-range temperature-compensated electrometer

    International Nuclear Information System (INIS)

    Stevenick, W. Van

    1994-01-01

    The performance of a complete pressurized ion chamber (PIC) radiation monitoring system is described. The design incorporates an improved temperature-compensated electrometer which is stable to ±3 · 10 -16 A over the environmental range of temperature (-40 to +40 C). Using a single 10 11 Ω feed-back resistor, the electrometer accurately measures currents over a range from 3 · 10 -15 A to 3 · 10 -11 A. While retaining the sensitivity of the original PIC system (the instrument responds readily to small background fluctuations on the order of 0.1 μR h -1 ), the new system measures radiation levels up to the point where the collection efficiency of the ion chamber begins to drop off, typically ∼27 pA at 1 mR h -1 . A data recorder and system controller was designed using the Tattletale trademark Model 4A computer. Digital data is stored on removable solid-state, credit-card style memory cards

  1. Environmental effects of using Methanol as a biofuel into the combustion chamber of a heavy-duty diesel engine

    Directory of Open Access Journals (Sweden)

    kianoosh shojae

    2016-12-01

    Full Text Available Methanol as a biofuel is an environmentally friendly substitute for pure diesel and can be obtained from biomasses. The use of biofuels such as methanol for the combustion process is associated with positive impacts on the environment. Using pure methanol or a blend of diesel/methanol fuel in motorized vehicles has been proposed by researchers. In this paper, pure methanol was injected into the combustion chamber of a ISM 370 HD diesel engine and the exhaust emissions were evaluated by using AVL FIRE CFD code software at four engine speeds (1200, 1400, 1600 and 1800 rpm. Additionally, the influences of EGR mass fraction and various injection timings were investigated. In order to validate the simulation results, in-cylinder mean pressure and rate of heat release (RHR were compared with experimental data, and the results gave an acceptable agreement. The obtained results from the conducted simulation showed that the use of methanol fuel in the combustion chamber dramatically reduced the amount of exhaust emissions such as NO, soot, CO, and CO2 to 90%, 75%, 40%, and 26%, respectively. In addition, a mass fraction of EGR (20% caused a reduction in the amount of exhaust NO to about 12%. It was determined that when a system is equipped with a fueling system at 3 deg before top dead center (BTDC, the exhaust NO and soot are reduced by 5.8% and 3%.

  2. Aging studies of resistive bulk Micromegas chambers for the ATLAS muon spectrometer upgrade

    CERN Document Server

    Spencer, Katie Louise

    2017-01-01

    A long-term operation study is presented as a probe of the aging properties of two bulk-resistive Micromegas chambers installed at the GIF$^{++}$ Gamma Irradiation Facility at CERN. Trends in the instantaneous chamber current, recorded over $\\approx$ 500 days of sustained exposure to the GIF$^{++}$ high intensity photon source, are analysed as a function of time in order to identify any signs of detector aging. As part of the study, additional variations in the current due to the changing external conditions of the chambers must be corrected for in order to isolate any aging effects. These include the changing chamber positions with respect to the photon source and the temperature and pressure fluctuations of the detector gas medium. Due to a number of subsets of the total irradiation period in which the exact detector positions are unknown, the aging study at the present time remains inconclusive. As a result, an alternative long-term aging study utilising the instantaneous chamber dark currents is suggested...

  3. Measurement of environmental gamma radiation by means of a large volume ionization chamber

    International Nuclear Information System (INIS)

    Gauthier, Daniel; Caput, Claude.

    1980-02-01

    A device for the measurement of the intensity of environmental gamma radiation has been realized and set up inside a vehicle especially fitted to that purpose. Because of its characteristics of sensitivity and time of response light and very local anomalies due for instance to foreign materials or punctual geological bassets can be detected and maps of dose rates at a regional scale can be drawn up. Such maps drawn before and after the operation of nuclear plants make it possible to assess their impact on environmental radiation levels [fr

  4. Study of pulp chamber morphology of primary mandibular molars using spiral computed tomography.

    Science.gov (United States)

    Selvakumar, Haridoss; Kavitha, Swaminathan; Vijayakumar, Rajendran; Eapen, Thomas; Bharathan, Rajendran

    2014-11-01

    The purpose of this study was to evaluate the pulp chamber morphology in primary mandibular molars using spiral computed tomography (SCT). Sixty extracted primary mandibular molars were scanned using SCT for the (i) distance between the central fissure to furcation, (ii) distance between the central fissure to the floor of the pulp chamber, (iii) height of the pulp chamber (roof-floor), (iv) distance between the floor of the pulp chamber to the furcation. The mean and standard deviation was analyzed using statistical package for the social sciences (SPSS) program. The results of this study show that the average mean distance from the central fissure to the floor of the pulp chamber is 5.07 mm in first mandibular primary molar and 5.54 mm in second mandibular primary molar. It can be concluded that the greatest depth to which a bur can go during access opening without perforating the furcation in first primary mandibular molar is 5.07 mm and 5.54 mm in second primary mandibular molar.

  5. Midday stomatal closure in Mediterranean type sclerophylls under simulated habitat conditions in an environmental chamber : II. Effect of the complex of leaf temperature and air humidity on gas exchange of Arbutus unedo and Quercus ilex.

    Science.gov (United States)

    Tenhunen, J D; Lange, O L; Braun, M

    1981-08-01

    Shrubs of the Mediterranean sclerophyllous species Arbutus unedo and Quercus ilex were studied under simulated habitat conditions in an environmental chamber. Temperature, humidity, and light intensity were altered stepwise to simulate diurnal changes in conditions similar to those measured in an evergreen macchia in Sobreda, Portugal. Leaves were enclosed in cuvettes which reproduced the growth chamber climate and which allowed measurement of gas exchange. Increasing atmospheric stress in the form of higher temperature and lower humidity on successive days gradually results in midday depression of transpiration rate and net photosynthesis rate of leaves due to midday stomatal closure.

  6. Study of the effect of water vapor on a resistive plate chamber with glass electrodes

    CERN Document Server

    Sakai, H H; Teramoto, Y; Nakano, E E; Takahashi, T T

    2002-01-01

    We studied the effects of water vapor on the efficiencies of resistive plate chambers with glass electrodes, operated in the streamer mode. With moisture in the chamber gas that has freon as a component (water vapor approx 1000 ppm), a decrease in the efficiency (approx 20%) has been observed after operating for a period of several weeks to a few months. From our study, the cause of the efficiency decrease was identified as a change on the cathode surface. In addition, a recovery method was found: flushing for 1 day with argon bubbled through water containing >=3% ammonia, followed by a few weeks of training with dry gas.

  7. Conceptual design study of the hylife lithium fall laser fusion chamber. FY 1979 annual report

    International Nuclear Information System (INIS)

    1979-01-01

    In FY 1979, the basic configuration of FY 1978 was used as a reference point. Many studies were then made to either generate more design information concerning this design or to produce new concepts that would lead to a superior configuration. Among these activities were a detailed weight analysis, an assembly sequence, a chamber vibration analysis, a splash baffle stress study, and an analysis of first wall thermal stresses. Then some new concepts were introduced that pertained to the first wall, the lithium inlet nozzle, the chamber supports, the inlet piping, and pressure vessel

  8. Is Climate Simulation in Growth Chambers Necessary?

    Science.gov (United States)

    Z.M. Wang; K.H. Johnsen; M.J. Lechowicz

    1999-01-01

    In the expression of their genetic potential as phenotypes, trees respond to environmental cues such as photoperiod, temperature and soil and atmospheric water. However, growth chamber experiments often utilize simple and standard environmental conditions that might not provide these important environmental signals. We conducted a study to compare seedling growth in...

  9. Final report for NIF chamber dynamics studies. Final report (May 1997), Subcontract No. B291847

    International Nuclear Information System (INIS)

    Peterson, P.F.; Jin, H.; Scott, J.M.

    1997-01-01

    The National Ignition Facility (NIF), a 1.8 MJ, 192 laser beam facility, will have anticipated fusion yields of up to 20 MJ from D-T pellets encased in a gold hohlraum target. The energy emitted from the target in the form of x rays, neutrons, target debris kinetic energy, and target shrapnel will be contained in a 5 m. radius spherical target chamber. Various diagnostics will be stationed around the target at varying distances from the target. During each shot, the target will emit x rays that will vaporize nearby target facing surfaces including those of the diagnostics, the target positioner, and other chamber structures. This ablated vapor will be transported throughout the chamber, and will eventually condense and deposit on surfaces in the chamber, including the final optics debris shields. The research at the University of California at Berkeley relates primarily to the NIF chamber dynamics. The key design issues are the ablation of the chamber structures, transport of the vapor through the chamber and the condensation or deposition processes of those vaporized materials. An understanding of these processes is essential in developing a concept for protecting the final optics debris shields from an excessive coating (> 10 Angstrom) of target debris and ablated material, thereby prolonging their lifetime between change- outs. At Berkeley, we have studied the physical issues of the ablation process and the effects of varying materials, the condensation process of the vaporized material, and design schemes that can lower the threat posed to the debris shields by these processes. In addition to the work described briefly above, we performed extensive analysis of the target-chamber thermal response to in- chamber CO 2 Cleaning and of work performed to model the behavior of silica vapor. The work completed this year has been published in several papers and a dissertation -6 This report provides a summary of the work completed this year, as well as copies of

  10. Environmental health studies

    International Nuclear Information System (INIS)

    Easterly, C.E.; Shank, K.E.

    1978-01-01

    The two major thrusts of the environmental health studies have been in the areas of health physics aspects of fusion power and methodology for assessing health effects related to nuclear facilities. Researchers were unable to discern a dose-response relationship or to find adverse health effects in the local population around nuclear facilities which might be related to radiation exposure. A second study analyzed the trends in incidence of cancer, congenital malformation, and fetal and infant mortality for Oak Ridge, Anderson County, and Roane County relative to Tennessee. Finally, a more in-depth study on congenital malformations and fetal mortality trends for nine East Tennessee counties surrounding Oak Ridge was completed. The objective of the Health Physics Aspects of Fusion Power Program is to provide, on a timely basis, scientific information and technical evaluations on the potential impacts of fusion power to occupational workers and to members of the public. The primary areas of study in this program during the past year have been (1) factors affecting calculations of dose resulting from a release of tritium, (2) an assessment of the potential for reducing occupational risk from exposures to tritium, and (3) experimental studies of tritium conversion from molecular hydrogen to tritiated water

  11. Drift velocity studies at a time projection chamber for various water contents in the gas mixture

    International Nuclear Information System (INIS)

    Stoever, F.W.

    2007-03-01

    For the answer of different open questions in high energy physics the construction of a linear e + e - collider with a c. m. energy of up to one TeV is prepared. With this is connected a comprehensive development on detectors, which must satisfy the requirements of the planned experiments. For the track chamber a TPC is considered. Hereby it deals with a gas-based concept, which has already been proved in past experiments and which is at time further developed by means of test chambers. The composition of the gas mixtureplays hereby an important role. Impurities of the gas mixture, especially by oxygen and water from the ambient air are a fact, which occurs every time in the development phase and can scarcely be avoided. From this arose the motivation to study directly the effects of this impurities. The object of the present thesis are correlations between drift velocity and water content in the chamber gas of a TPC

  12. Studies of light emission by continuously sensitive avalanche chambers

    International Nuclear Information System (INIS)

    Charpak, G.; Dominik, W.; Fabre, J.P.; Gaudaen, J.; Sauli, F.; Suzuki, M.

    1988-01-01

    The optimal conditions for the optical recording of images of electron avalanches between parallel meshes have been studied. The emission spectra of gas mixtures have been investigated, where triethylamine (TEA), tetrakis(dimethylamine)ethylene (TMAE), and nitrogen, are used as the photon-emitting agents. For a given charge gain, the photon intensity decreases with electric field. This favours amplification between parallel meshes instead of wires. The use of intensified CCD cameras permits the recording of the local energy loss along the tracks. (orig.)

  13. Performance Studies of a Micromegas Chamber in the ATLAS Environment

    CERN Document Server

    Kataoka, Y; Ntekas, K

    2014-01-01

    Five small prototype micromegas detectors were positioned in the ATLAS detector during Large Hadron Collider running at $\\sqrt{s} = 7$ and $8\\, \\mathrm{TeV}$. A $9\\times 4.5\\, \\mathrm{cm^2}$ two-gap detector was placed in front of the electromagnetic calorimeter and four $9\\times 10\\, \\mathrm{cm^2}$ detectors on the ATLAS Small Wheel, the first station of the forward muon spectrometer. The one attached to the calorimeter was exposed to interaction rates of about $70\\,\\mathrm{kHz}$ at $\\mathcal{L}=5\\times 10^{33}\\,\\mathrm{cm^{-2}s^{-1}}$ two orders of magnitude higher than the rates in the Small Wheel. We present the results from performance studies carried out using data collected with these detectors and we also compare the currents drawn by the detector installed in front of the electromagnetic calorimeter with the luminosity measurement in ATLAS.

  14. A Preliminary Study on Time Projection Chamber Simulation for Fission Cross Section Measurements with Geant4

    International Nuclear Information System (INIS)

    Kim, Jong Woon; Lee, Youngouk; Kim, Jae Cheon

    2014-01-01

    We present the details of the TPC simulation with Geant4 and show the results. TPC can provide more information than a fission chamber in that it is possible to distinguish different particle types. Simulations are conducted for uranium and plutonium targets with 20MeV neutrons. The simulation results are compared with the reference and show reasonable results. This is the first phase of study for realizing a TPC in the NFS at RAON, and we have more work to do, such as applying an electric field, signal processing in the simulation, and manufacturing of a TPC. The standard in fission cross section measurement is a fission chamber. It is basically just two parallel plates separated by a few centimeters of gas. A power supply connected to the plates sets up a moderate electric field. The target is deposited onto one of the plates. When fission occurs, the fragments ionize the gas, and the electric field causes the produced electrons to drift to the opposite plate, which records the total energy deposited in the chamber. A Time Projection Chamber (TPC) is a gas ionization detector similar to a fission chamber. However, it can measure the charged particle trajectories in the active volume in three dimensions by adding several readouts on the pad plane (fission chamber has only one readout one a pad plane). The specific ionization for each particle track enables the TPC to distinguish different particle types. A TPC will be used for fission cross section measurements in the Neutron Science Facility (NSF) at RAON. As a preliminary study, we present details of TPC simulation with Geant4 and discuss the results

  15. Operation of Resistive Plate Chamber Detectors with a New Environmentally Friendly Freon

    CERN Document Server

    Lewis, Helen Elizabeth

    2014-01-01

    RPC particle gas detectors at CERN provide a vital element to the physics experiments carried out on the LHC. While their current operation and working gas mixtures are successful, environ- mental and economic factors force a revision of the mixture, specifically the eventual replacement of the current Freon gas R134-a with a newer, less environmentally harmful formulation, namely R1234-yf. The methods and results presented here outline the detector response to the introduction of the new Freon and its behavior under various mixtures. The electronegativity and hence impact on RPC parameters was investigated. It was found that the new Freon gas is indeed electroneg- ative, and suppresses the RPC signal. The mixture was modified to include Argon to increase ionization, and the final results of the operation of the RPC were satisfactory. Further work to refine the mixture for future implementation is necessary.

  16. Reactor oscillator project - Theoretical study; operation problems; choice of the ionization chamber

    International Nuclear Information System (INIS)

    Lolic, B.; Markovic, V.

    1961-01-01

    Theoretical study of the reactor operator covers methods of the danger coefficient and the method based on measuring the phase angle. Operation with the reactor oscillator describes measurement of the cross section and resonance integral, measurement of the fissionable materials properties, measurement of impurities in the graphite sample. A separate chapter is devoted to the choice of the appropriate ionization chamber

  17. Experimental study of the counting loss in an ionization chamber in pulsed radiation fields

    International Nuclear Information System (INIS)

    Goncalez, O.L.; Yanagihara, L.S.; Veissid, V.L.C.P.; Herdade, S.B.; Teixeira, A.N.

    1983-01-01

    The behavior of an ionization chamber gamma ray monitor in a pulsed radiation field at a linear electron accelerator facility was studied experiementally. A loss of sensitivity was observed as expected due to the pulsed nature of the radiation. By fitting the experiemental data to semi-empirical expressions, parameters for the correction of the counting efficiency were obtained. (Author) [pt

  18. [Corrected Title: Solid-Phase Extraction of Polar Compounds from Water] Automated Electrostatics Environmental Chamber

    Science.gov (United States)

    Sauer, Richard; Rutz, Jeffrey; Schultz, John

    2005-01-01

    A solid-phase extraction (SPE) process has been developed for removing alcohols, carboxylic acids, aldehydes, ketones, amines, and other polar organic compounds from water. This process can be either a subprocess of a water-reclamation process or a means of extracting organic compounds from water samples for gas-chromatographic analysis. This SPE process is an attractive alternative to an Environmental Protection Administration liquid-liquid extraction process that generates some pollution and does not work in a microgravitational environment. In this SPE process, one forces a water sample through a resin bed by use of positive pressure on the upstream side and/or suction on the downstream side, thereby causing organic compounds from the water to be adsorbed onto the resin. If gas-chromatographic analysis is to be done, the resin is dried by use of a suitable gas, then the adsorbed compounds are extracted from the resin by use of a solvent. Unlike the liquid-liquid process, the SPE process works in both microgravity and Earth gravity. In comparison with the liquid-liquid process, the SPE process is more efficient, extracts a wider range of organic compounds, generates less pollution, and costs less.

  19. Thermal Studies of the Laser Inertial Fusion Energy (LIFE) Target during Injection into the Fusion Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Miles, R. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Havstad, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); LeBlanc, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chang, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Golosker, I. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rosso, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-09-09

    The tests of the external heat transfer coefficient suggests that the values used in the numerical analysis for the temperature distribution within the fusion fuel target following flight into the target chamber are probably valid. The tests of the heat transfer phenomena occurring within the target due the rapid heating of the LEH window for the hot gasses within the fusion chamber show that the heat does indeed convect via the internal helium environment of the target towards the capsule and that the pressure in the front compartment of the target adjacent to the LEH window increases such that t bypass venting of the internal helium into the second chamber adjacent to the capsule is needed to prevent rupture of the membranes. The bypass flow is cooled by the hohlraum during this venting. However, the experiments suggest that our internal heat flow calculations may be low by about a factor of 2. Further studies need to be conducted to investigate the differences between the experiment and the numerical analysis. Future studies could also possibly bring the test conditions closer to those expected in the fusion chamber to better validate the results. A sacrificial layer will probably be required on the LEH window of the target and this can be used to mitigate any unexpected target heating.

  20. Summary of Previous Chamber or Controlled Anthrax Studies and Recommendations for Possible Additional Studies

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Morrow, Jayne B.

    2010-12-29

    This report and an associated Excel file(a) summarizes the investigations and results of previous chamber and controlled studies(b) to characterize the performance of methods for collecting, storing and/or transporting, extracting, and analyzing samples from surfaces contaminated by Bacillus anthracis (BA) or related simulants. This report and the Excel are the joint work of the Pacific Northwest National Laboratory (PNNL) and the National Institute of Standards and Technology (NIST) for the Department of Homeland Security, Science and Technology Directorate. The report was originally released as PNNL-SA-69338, Rev. 0 in November 2009 with limited distribution, but was subsequently cleared for release with unlimited distribution in this Rev. 1. Only minor changes were made to Rev. 0 to yield Rev. 1. A more substantial update (including summarizing data from other studies and more condensed summary tables of data) is underway

  1. Performance Studies of Micromegas Chambers for the New Small Wheel Upgrade Project

    Directory of Open Access Journals (Sweden)

    Leontsinis S.

    2016-01-01

    Full Text Available The ATLAS collaboration has chosen the Micromegas technology along with the small-strip Thin Gap Chambers for the upgrade of the inner muon station in the high-rapidity region, the so called New Small Wheel upgrade project. It will employ eight layers of Micromegas and eight layers of small-strip Thin Gap Chambers per wheel. The New Small Wheel project requires fully efficient Micromegas chambers, able to cope with the maximum expected rate of 15 kHz/cm2 featuring single plane spatial resolution better than 100 μm. The Micromegas detectors will cover a total active area of ~ 1200 m2 and will be operated in a moderate magnetic field (≤ 0.3 T. Moreover, together with their precise tracking capability the New Small Wheel Micromegas chambers will contribute to the ATLAS Level-1 trigger system. Several studies have been performed on small (10 × 10 cm2 and medium (1 × 0.5 m2 size prototypes using medium (1 − 5 GeV/c and high momentum (120 – 150 GeV/c hadron beams at CERN. A brief overview of the results obtained is presented.

  2. The Ussing Chamber Assay to Study Drug Metabolism and Transport in the Human Intestine.

    Science.gov (United States)

    Kisser, Beatrice; Mangelsen, Eva; Wingolf, Caroline; Partecke, Lars Ivo; Heidecke, Claus-Dieter; Tannergren, Christer; Oswald, Stefan; Keiser, Markus

    2017-06-22

    The Ussing chamber is an old but still powerful technique originally designed to study the vectorial transport of ions through frog skin. This technique is also used to investigate the transport of chemical agents through the intestinal barrier as well as drug metabolism in enterocytes, both of which are key determinants for the bioavailability of orally administered drugs. More contemporary model systems, such as Caco-2 cell monolayers or stably transfected cells, are more limited in their use compared to the Ussing chamber because of differences in expression rates of transporter proteins and/or metabolizing enzymes. While there are limitations to the Ussing chamber assay, the use of human intestinal tissue remains the best laboratory test for characterizing the transport and metabolism of compounds following oral administration. Detailed in this unit is a step-by-step protocol for preparing human intestinal tissue, for designing Ussing chamber experiments, and for analyzing and interpreting the findings. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  3. Study of energy determination of gamma-ray observed with an emulsion chamber with a large gap

    International Nuclear Information System (INIS)

    Inui, Tamiki; Otsuka, Taeko; Masaoka, Akiko

    1982-01-01

    The development of large size emulsion chambers has been made to study very high energy events. For this purpose, the chambers with exchangeable light sensitive layers are considered. The chambers have large gap for the exchange. In this case, it becomes hard to determine the energy of cascade shower. In this report, the authors describe on the experimental examples observed at Mt. Chacaltaya. The effect of a gap was investigated by these examples, and the simulation method by Okamoto and Shibata was applied to the chamber. The chamber used for the observation consisted of the top chamber of 11 c.u. and the bottom chamber of 15 c.u. There was a large gap of 170 cm between two chambers. Twelve showers in three families observed by this system were analyzed. The difference between the blackness in the top and bottom films was studied quantitatively. The blackness was calibrated for the electron density. Four methods of energy determination were studied. Among them, a method to employ the sum of the maximum blackness of a top film and that of a bottom one was used for the analysis. This method seemed to be more reliable than the old method. It was found by a simulation calculation that the recovery of shower in the bottom chamber was seen not only by hardrons but also by gamma-ray. (Kato, T.)

  4. An experimental study on removal efficiency of bio-particles in an airtight decontamination chamber

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yanju [School of Environment Science and Technology, Tianjin University, Tianjin (China); National Biological Protection Engineering Center, Tianjin (China); Hao, Limei; Wang, Shuang; Hou, Lili; Zhang, Jinming; Qi, Jiancheng [National Biological Protection Engineering Center, Tianjin (China)

    2009-11-15

    Many bacteria and viruses lead to global dissemination of respiratory diseases, such as SARS, influenza, tuberculosis, pneumonia and asthma, by clinging to particles and transmission through aerosol. In this paper, an experiment was conducted to investigate the removal efficiency of bio-particles when exposed to ventilation in an airtight decontamination chamber made of stainless steel. After the bio-particles (Serratia marcescens) exposure condition was established in the chamber, the bio-particles removal efficiency was investigated. And a comparison experiment was then conducted with polystyrene latex spheres (PSL) as general particles under the same environmental condition. The comparison results indicate that the removal efficiency of bio-particles is lower than that of PSL during the first 300 s, but both removal efficiencies reached 90% almost at the same time. Furthermore, the differences between bio-particles and PSL, the influence of bio-particle size, environmental velocity, temperature and relative humidity on bio-particle removal efficiency were analyzed and discussed comprehensively. These data could not only underpin future numerical simulations of bio-particles, but also give information to aid in decisions for decreasing the risk of bio-particles pollution in a microbe exposure environment. (author)

  5. Analysis of high mass resolution PTR-TOF mass spectra from 1,3,5-trimethylbenzene (TMB) environmental chamber experiments

    Science.gov (United States)

    Müller, M.; Graus, M.; Wisthaler, A.; Hansel, A.; Metzger, A.; Dommen, J.; Baltensperger, U.

    2012-01-01

    A series of 1,3,5-trimethylbenzene (TMB) photo-oxidation experiments was performed in the 27-m3 Paul Scherrer Institute environmental chamber under various NOx conditions. A University of Innsbruck prototype high resolution Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-TOF) was used for measurements of gas and particulate phase organics. The gas phase mass spectrum displayed ~200 ion signals during the TMB photo-oxidation experiments. Molecular formulas CmHnNoOp were determined and ion signals were separated and grouped according to their C, O and N numbers. This allowed to determine the time evolution of the O:C ratio and of the average carbon oxidation state solid #000; color: #000;">OSC of the reaction mixture. Both quantities were compared with master chemical mechanism (MCMv3.1) simulations. The O:C ratio in the particle phase was about twice the O:C ratio in the gas phase. Average carbon oxidation states of secondary organic aerosol (SOA) samples solid #000; color: #000;">OSCSOA were in the range of -0.34 to -0.31, in agreement with expected average carbon oxidation states of fresh SOA (solid #000; color: #000;">OSC = -0.5-0).

  6. A multiwire proportional chamber for precision studies of neutron β decay angular correlations

    International Nuclear Information System (INIS)

    Ito, T.M.; Carr, R.; Filippone, B.W.; Martin, J.W.; Plaster, B.; Rybka, G.; Yuan, J.

    2007-01-01

    A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron β decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas and an entrance window made of thin Mylar sheet reinforced with Kevlar fibers. In the initial off-line performance tests, the gas gain of neopentane and the position resolution were studied

  7. Method for detecting and distinguishing between specific types of environmental radiation using a high pressure ionization chamber with pulse-mode readout

    Science.gov (United States)

    Degtiarenko, Pavel V.

    2017-12-19

    An environmental radiation detector for detecting and distinguishing between all types of environmental radiation, including photons, charged particles, and neutrons. A large volume high pressure ionization chamber (HPIC) includes BF.sub.3 gas at a specific concentration to render the radiation detector sensitive to the reactions of neutron capture in Boron-10 isotope. A pulse-mode readout is connected to the ionization chamber capable of measuring both the height and the width of the pulse. The heavy charged products of the neutron capture reaction deposit significant characteristic energy of the reaction in the immediate vicinity of the reaction in the gas, producing a signal with a pulse height proportional to the reaction energy, and a narrow pulse width corresponding to the essentially pointlike energy deposition in the gas. Readout of the pulse height and the pulse width parameters of the signals enables distinguishing between the different types of environmental radiation, such as gamma (x-rays), cosmic muons, and neutrons.

  8. Endoscopic biopsies in Ussing chambers evaluated for studies of macromolecular permeability in the human colon.

    Science.gov (United States)

    Wallon, Conny; Braaf, Ylva; Wolving, Mats; Olaison, Gunnar; Söderholm, Johan D

    2005-05-01

    Studies of mucosal permeability to protein antigens in humans are limited to in vitro techniques. The use of surgical specimens for such studies has major shortcomings. Endoscopic biopsies in Ussing chambers have been introduced as a means of studying secretion and transepithelial permeability, but have not been evaluated for studies of protein antigen uptake in human intestine. Standard forceps biopsies from the sigmoid colon of 24 healthy volunteers were mounted in Ussing chambers with an exposed tissue area of 1.76 mm2. 51Cr-EDTA (paracellular probe) and horseradish peroxidase (HRP; 45 kDa protein antigen) were used as permeability markers. Mucosal permeability, electrophysiology, histology and energy contents of the biopsies were studied over time. To evaluate the ability of the technique to detect permeability changes, the mucosa was modulated with capric acid, a medium-chain fatty acid, known to affect tight junctions. In the Ussing chamber the mucosal biopsies were viable for 160 min with stable levels of ATP and lactate, and only minor changes in morphology. Steady-state permeability with low variability was seen for both markers during the 30-90 min period. Exposure to capric acid induced a rapid decrease in short-circuit current (Isc) and a slower reversible decrease in transepithelial resistance (TER), as well as an increased permeability to 51Cr-EDTA and HRP. Endoscopic biopsies of human colon are viable in Ussing chambers and are reliable tools for studies of mucosal permeability to protein antigens. The technique offers a broad potential for studies of mucosal function in the pathophysiology of human gastrointestinal diseases.

  9. Study of a proportional chamber for the detection of muons in the CELLO experiment

    International Nuclear Information System (INIS)

    Durand, Alain.

    1978-01-01

    The physics of e + e - interactions that the CELLO experiment is proposing to do requires good μ detection. For this, the prototype of a wire type proportional chamber with integrated logical system read-out is under study. The various phenomena that govern the working of a wire type proportional chamber are recalled first of all. Section II deals with the various working and read-out modes. Section III is devoted to the description of the method chosen and its advantages. In Sections IV and V, the two more specifically studied read-out methods are presented and it is shown that the read-out method by delay line proves to be much more delicate to use than the integrated electronic method finally selected [fr

  10. A study of the air-shower response of current-limited spark chambers

    International Nuclear Information System (INIS)

    Porter, M.R.; Hodson, A.L.; Bull, R.M.

    1982-01-01

    The efficiency of current-limited spark chambers (discharge chambers) and their relative response to shower electrons and photons are investigated. A stack of six horizontal 1m x 10 cm discharge chambers, above one another, is triggered by air showers falling on an adjacent discharge-chamber array. Particular combinations of discharges show that the efficiency of the chambers is very high and that a significant fraction of the discharges is due to incident photons

  11. Study of influence of gas mixture composition on the multistep avalanche chambers characteristics

    International Nuclear Information System (INIS)

    Abdushukurov, D.A.; Zanevskij, Yu.V.; Peshekhonov, V.D.

    1987-01-01

    The influence of the concentration of organic quenchers on the operation of multistep avalanche chambers /MSAC/ has been studied. An empirical dependence of the gas amplification factor of MSAC on the quencher concentration has been derived. Measures are considered to increase the stability of the MSAC operation. To improve the MSAC operation argon + n-heptane, neon + methane and neon + argon + methane mixtures are suggested

  12. Ionization chamber

    International Nuclear Information System (INIS)

    Jilbert, P.H.

    1975-01-01

    The invention concerns ionization chambers with particular reference to air-equivalent ionization chambers. In order to ensure that similar chambers have similar sensitivities and responses the surface of the chamber bounding the active volume carries a conducting material, which may be a colloidal graphite, arranged in the form of lines so that the area of the conducting material occupies only a small proportion of the area of said surface. (U.S.)

  13. A study of the response of a gas ionization chamber to different sources of ionizing radiation

    International Nuclear Information System (INIS)

    Zamble-Dieguez, F.E.

    1988-05-01

    The response of the TAMU Forward Hadron Calorimeter Chambers to neutrons from a 2 39Pu-Be source was investigated in hope of developing a strategy to reduce the effects of the background events called /open quotes/Texas towers/close quotes/ in the CDF trigger for the next run. The response to a standard ( 5 5Fe γ-ray) energy source was also studied and found to be similar to that of the chambers installed at CDF. In addition, the effects of different sampling gases and intermediate absorbers on the rate of large energy pulses were investigated. The neutron data were compared with the energy spectrum measured in CDF and that simulated using Monte Carlo techniques. It was found that the large energy pulse frequency can be reduced by as much as 50% if a non-hydrogenous sampling gas is used in conjunction with a neutron moderator

  14. Study of behaviour of the monitor chambers of a linear accelerator for medical use

    International Nuclear Information System (INIS)

    Brosed, A.; Lopez-Bote, M.A.; Blanco, M.A.; Galvez, M.

    1988-01-01

    An experimental procedure to study the nature and behaviour of the monitor chambers of a linear accelerator for medical use is presented. The procedure has been applied to a Siemens accelerator, Mevatron-77, that has two different types of monitor chambers: sealed for the photon beam and unsealed for the electron ones. As it was expected, no deviations in the dose per monitor unit has been obtained for the photon beam. Variations in the absorbed dose per monitor unit have been observed for the electron beams up to 6% along the working day. Practical solutions compensating this fact are pointed out and the standard recommendations on the control of dose per monitor unit are discussed. (Author)

  15. A Monte Carlo study of radon detection in cylindrical diffusion chambers

    Energy Technology Data Exchange (ETDEWEB)

    Rickards, Jorge, E-mail: rickards@fisica.unam.m [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito de la Investigacion Cientifica, Ciudad Universitaria, Delegacion Coyoacan, 04520 Mexico, D.F. (Mexico); Golzarri, Jose-Ignacio, E-mail: golzarri@fisica.unam.m [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito de la Investigacion Cientifica, Ciudad Universitaria, Delegacion Coyoacan, 04520 Mexico, D.F. (Mexico); Espinosa, Guillermo, E-mail: espinosa@fisica.unam.m [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito de la Investigacion Cientifica, Ciudad Universitaria, Delegacion Coyoacan, 04520 Mexico, D.F. (Mexico)

    2010-05-15

    The functioning of radon diffusion chambers was studied using the Monte Carlo code RAMMX developed here. The alpha particles from radon are assumed randomly produced in the volume of the cylinder, and those from the progeny are assumed to originate randomly at the cylindrical surface. The energy spectrum, the distribution of incident angles, and the distribution of path lengths of the alpha particles on the detector were obtained. These quantities vary depending on input parameters such as initial alpha particle energy, radius and depth of the diffusion chamber, detector size and atmospheric pressure. The calculated energy spectrum for both {sup 222}Rn and {sup 220}Rn was compared with experiment, permitting the identification of each peak and its origin, and a better understanding of radon monitoring. Three aspects not considered in previous calculations are progeny alphas coming from surfaces of the monitor, taking into account the atmospheric pressure, and including the isotope {sup 220}Rn.

  16. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  17. Knudsen cell and smog chamber study of the heterogeneous uptake of sulfur dioxide on Chinese mineral dust.

    Science.gov (United States)

    Zhou, Li; Wang, Weigang; Gai, Yanbo; Ge, Maofa

    2014-12-01

    The heterogeneous uptake processes of sulfur dioxide on two types of Chinese mineral dust (Inner Mongolia desert dust and Xinjiang sierozem) were investigated using both Knudsen cell and smog chamber system. The temperature dependence of the uptake coefficients was studied over a range from 253 to 313 K using the Knudsen cell reactor, the initial uptake coefficients decreased with the increasing of temperature for these two mineral dust samples, whereas the steady state uptake coefficients of the Xinjiang sierozem increased with the temperature increasing, and these temperature dependence functions were obtained for the first time. In the smog chamber experiments at room temperature, the steady state uptake coefficients of SO2 decreased evidently with the increasing of sulfur dioxide initial concentration from 1.72 × 10¹² to 6.15 × 10¹² mol/cm³. Humid air had effect on the steady state uptake coefficients of SO₂onto Inner Mongolia desert dust. Consequences about the understanding of the uptake processes onto mineral dust samples and the environmental implication were also discussed. Copyright © 2014. Published by Elsevier B.V.

  18. Chamber study of PCB emissions from caulking materials and light ballasts.

    Science.gov (United States)

    Liu, Xiaoyu; Guo, Zhishi; Krebs, Kenneth A; Stinson, Rayford A; Nardin, Joshua A; Pope, Robert H; Roache, Nancy F

    2015-10-01

    The emissions of polychlorinated biphenyl (PCB) congeners from thirteen caulk samples were tested in a micro-chamber system. Twelve samples were from PCB-contaminated buildings and one was prepared in the laboratory. Nineteen light ballasts collected from buildings that represent 13 different models from five manufacturers were tested in 53-L environmental chambers. The rates of PCB congener emissions from caulking materials and light ballasts were determined. Several factors that may have affected the emission rates were evaluated. The experimentally determined emission factors showed that, for a given PCB congener, there is a linear correlation between the emission factor and the concentration of the PCB congener in the source. Furthermore, the test results showed that an excellent log-linear correlation exists between the normalized emission factor and the vapor pressure (coefficient of determination, r(2)⩾0.8846). The PCB congener emissions from ballasts at or near room temperature were relatively low with or without electrical load. However, the PCB congener emission rates increased significantly as the temperature increased. The results of this research provide new data and models for ranking the primary sources of PCBs and supports the development and refinement of exposure assessment models for PCBs. Published by Elsevier Ltd.

  19. Electron microscopic evidence for the myosin head lever arm mechanism in hydrated myosin filaments using the gas environmental chamber

    International Nuclear Information System (INIS)

    Minoda, Hiroki; Okabe, Tatsuhiro; Inayoshi, Yuhri; Miyakawa, Takuya; Miyauchi, Yumiko; Tanokura, Masaru; Katayama, Eisaku; Wakabayashi, Takeyuki; Akimoto, Tsuyoshi; Sugi, Haruo

    2011-01-01

    Research highlights: → We succeeded in recording structural changes of hydrated myosin cross-bridges. → We succeeded in position-marking the cross-bridges with site-directed antibodies. → We recorded cross-bridge movement at different regions in individual cross-bridge. → The movement was smallest at the cross-bridge-subfragment two boundary. → The results provide evidence for the cross-bridge lever arm mechanism. -- Abstract: Muscle contraction results from an attachment-detachment cycle between the myosin heads extending from myosin filaments and the sites on actin filaments. The myosin head first attaches to actin together with the products of ATP hydrolysis, performs a power stroke associated with release of hydrolysis products, and detaches from actin upon binding with new ATP. The detached myosin head then hydrolyses ATP, and performs a recovery stroke to restore its initial position. The strokes have been suggested to result from rotation of the lever arm domain around the converter domain, while the catalytic domain remains rigid. To ascertain the validity of the lever arm hypothesis in muscle, we recorded ATP-induced movement at different regions within individual myosin heads in hydrated myosin filaments, using the gas environmental chamber attached to the electron microscope. The myosin head were position-marked with gold particles using three different site-directed antibodies. The amplitude of ATP-induced movement at the actin binding site in the catalytic domain was similar to that at the boundary between the catalytic and converter domains, but was definitely larger than that at the regulatory light chain in the lever arm domain. These results are consistent with the myosin head lever arm mechanism in muscle contraction if some assumptions are made.

  20. Building Transdisciplinary Environmental Studies

    DEFF Research Database (Denmark)

    Holm, Jesper

    2006-01-01

    Conceptual analytical-methodological conceptualization of crossdisciplinary sustainability studies......Conceptual analytical-methodological conceptualization of crossdisciplinary sustainability studies...

  1. Performance studies of resistive Micromegas chambers for the upgrade of the ATLAS Muon Spectrometer

    Science.gov (United States)

    Ntekas, Konstantinos

    2018-02-01

    The ATLAS collaboration at LHC has endorsed the resistive Micromegas technology (MM), along with the small-strip Thin Gap Chambers (sTGC), for the high luminosity upgrade of the first muon station in the high-rapidity region, the so called New Small Wheel (NSW) project. The NSW requires fully efficient MM chambers, up to a particle rate of ˜ 15 kHz/cm2, with spatial resolution better than 100 μm independent of the track incidence angle and the magnetic field (B ≤ 0.3 T). Along with the precise tracking the MM should be able to provide a trigger signal, complementary to the sTGC, thus a decent timing resolution is required. Several tests have been performed on small (10 × 10 cm2) MM chambers using medium (10 GeV/c) and high (150 GeV/c) momentum hadron beams at CERN. Results on the efficiency and position resolution measured during these tests are presented demonstrating the excellent characteristics of the MM that fulfil the NSW requirements. Exploiting the ability of the MM to work as a Time Projection Chamber a novel method, called the μTPC, has been developed for the case of inclined tracks, allowing for a precise segment reconstruction using a single detection plane. A detailed description of the method along with thorough studies towards refining the method's performance are shown. Finally, during 2014 the first MM quadruplet (MMSW) following the NSW design scheme, comprising four detection planes in a stereo readout configuration, has been realised at CERN. Test-beam results of this prototype are discussed and compared to theoretical expectations.

  2. Intensive irradiation studies, monitoring and commissioning data analysis on the ATLAS MDT chambers

    CERN Document Server

    AUTHOR|(CDS)2071390; Susinno, Giancarlo

    2007-01-01

    The ATLAS MDT chambers have been extensively studied, starting from irradiation test to commissioning activities. First, a detailed description of high rate and high background tests is given. These tests have been carried out on a small ATLAS-like MDT chamber, by the Cosenza and Roma TRE groups. The precision tracking chambers of the muon spectrometer, in fact, have to operate for more than 10 years in the harsh LHC background, due mainly to low energy neutrons and photons. Aging effects, such as the deterioration of the tube themselves can appear and difficulties in pattern recognition and tracking may occur. Moreover an upgrade to Super-LHC is foreseen. Then, there is an accurate description of the MDTGnam package, the official software for the on-line monitoring of MDT performances. When dealing with a complex apparatus, such as the ATLAS experiment, an on-line monitoring system is a fundamental tool. The GNAM project, developed by Cosenza, Pavia, Pisa and Napoli groups, is a monitoring framework to be us...

  3. Development of fission micro-chambers for nuclear waste incineration studies

    CERN Document Server

    Fadil, M; Christophe, S; Deruelle, O; Fioni, G; Marie, F; Mounier, C; Ridikas, D; Trapp, J P

    2002-01-01

    The Incineration by Accelerator (INCA) project of the Directorate for Science of Matter of the French Atomic Energy Authority (CEA/DSM) aims to outline the ideal physical conditions to transmute minor actinides in a high intensity neutron flux obtained either by hybrid systems or innovative critical reactors. To measure on-line the incineration rates of minor actinides, we are developing an innovative Double Deposit Fission Chamber (DDFC) working in current mode. Our method is based on a comparison between the isotope under study and a reference material whose nuclear parameters are well known, as sup 2 sup 3 sup 5 U and sup 2 sup 3 sup 9 Pu. This new fission chamber will be used in the High Flux Reactor in Grenoble/France in a neutron flux of 1.2x10 sup 1 sup 5 n cm sup - sup 2 s sup - sup 1 for 50 days, the operating cycle of the reactor. These specific experimental conditions require substantial modifications of the existing chambers. The first experiment will be carried out in fall 2000.

  4. Study of Parameters Effect on Hydrodynamics of a Gas-Solid Chamber Experimentally and Numerically

    Directory of Open Access Journals (Sweden)

    Rahimzadeh Hassan

    2012-04-01

    Full Text Available In this research, gas velocity, initial static bed height and particle size effect on hydrodynamics of a non-reactive gas–solid fluidized bed chamber were studied experimentally and computationally. A multi fluid Eulerian model incorporating the kinetic theory for solid particles was applied to simulate the unsteady state behavior of this chamber and momentum exchange coefficients were calculated by using the Syamlal- O’Brien drag functions. Simulation results were compared with the experimental data in order to validate the CFD model. Pressure drops predicted by the simulations at different particle sizes and initial static bed height were in good agreement with experimental measurements at superficial gas velocity higher than the minimum fluidization velocity. Simulation results also indicated that small bubbles were produced at the bottom of the bed. These bubbles collided with each other as they moved upwards forming larger bubbles. Furthermore, this comparison showed that the model can predict hydrodynamic behavior of gas solid fluidized bed chambers reasonably well.

  5. Microbial volatile organic compounds in moldy interiors: a long-term climate chamber study.

    Science.gov (United States)

    Schuchardt, Sven; Strube, Andrea

    2013-06-01

    The present study simulated large-scale indoor mold damage in order to test the efficiency of air sampling for the detection of microbial volatile organic compounds (MVOCs). To do this, a wallpaper damaged by condensation was stored in a climate chamber (representing a hypothetical test room of 40 m(3) volume) and was inoculated with 14 typical indoor fungal strains. The chamber ventilation conditions were adjusted to common values found in moldy homes, and the mold growth was allowed to continue to higher than average values. The MVOC content of the chamber air was analyzed daily for a period of 105 days using coupled gas chromatography/mass spectrometry (GC-MS). This procedure guarantees MVOC profiling without external factors such as outdoor air, building materials, furniture, and occupants. However, only nine MVOCs could be detected during the sampling period, which indicates that the very low concentrated MVOCs are hardly accessible, even under these favorable conditions. Furthermore, most of the MVOCs that were detected cannot be considered as reliable indicators of mold growth in indoor environments. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Study on time response character for high pressure gas ionization chamber of krypton and xenon

    International Nuclear Information System (INIS)

    Tan Chunming; Wu Haifeng; Qing Shangyu; Wang Liqiang

    2006-01-01

    The time response character for Kr and Xe high pressure gas ionization chamber is analyzed and deduced. Compared with the measure data of pulse rising time for three gas-filled ionization chambers, the calculated and experimental results are equal to each other. The rising time less than 10 ms for this kind of ionization chamber can be achieved, so this ionization chamber is able to meet the requirement for imaging detection. (authors)

  7. [Study of high energy nucleus-nucleus interactions with a Magnetic-Interferometric-Emulsion-Chamber

    International Nuclear Information System (INIS)

    Takahashi, Yoshiyuki.

    1990-01-01

    The Nuclear Physics group at the University of Alabama in Huntsville (UAH) has been analyzing 200 GeV/n S + Pb collision events with a Magnetic-Interactive-Emulsion-Chamber (MAGIC). The objectives of the research are to learn the nature of nuclear matter at high density of particles and to develop an all-particle tracking system for very high particle densities. To advance the study further, the detector capability has been improved so as to allow the best utilization of all-particle measurements. A design study for Pb + Pb interactions at 160 GeV/n was made for planned experiments in 1993

  8. Preliminary study of silica aerogel as a gas-equivalent material in ionization chambers

    Science.gov (United States)

    Caresana, M.; Zorloni, G.

    2017-12-01

    Since about two decades, a renewed interest on aerogels has risen. These peculiar materials show fairly unique properties. Thus, they are under investigation for both scientific and commercial purposes and new optimized production processes are studied. In this work, the possibility of using aerogel in the field of radiation detection is explored. The idea is to substitute the gas filling in a ionization chamber with the aerogel. The material possesses a density about 100 times greater than ambient pressure air. Where as the open-pore structure should allow the charge carriers to move freely. Small hydrophobic silica aerogel samples were studied. A custom ionization chamber, capable of working both with aerogel or in the classic gas set up, was built. The response of the chamber in current mode was investigated using an X-ray tube. The results obtained showed, under proper conditions, an enhancement of about 60 times of the current signal in the aerogel configuration with respect to the classic gas one. Moreover, some unusual behaviours were observed, i.e. time inertia of the signal and super-/sub-linear current response with respect to the dose rate. While testing high electric fields, aerogel configuration seemed to enhance the Townsend's effects. In order to represent the observed trends, a trapping-detrapping model is proposed, which is capable to predict semi-empirically the steady state currents measured. The time evolution of the signal is semi-quantitatively represented by the same model. The coefficients estimated by the fits are in agreement with similar trapping problems in the literature. In particular, a direct comparison between the benchmark of the FET silica gates and aerogel case endorses the idea that the same type of phenomenon occurs in the studied case.

  9. Biotechnology and environmental studies

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This program is concerned with the development of biochemical engineering technology whereby individual process steps, at least one of which utilizes a biological entity, can be integrated to result in a highly useful overall process. Areas of concern to DOE that will benefit directly from this technology include energy production and conservation, resource recovery, and pollution abatement. Investigations specific to problems in nuclear waste management include the removal of radionuclides and chemical contaminants from aqueous process and effluent streams. Bioengineering research activities were focused on three areas during this reporting period: enzyme catalysis; treatment of aqueous effluents from coal conversion processes; and bioreactor scale-up and process modeling studies

  10. Geologic environmental study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chun Soo; Bae, Dae Seok; Kim, Kyung Su; Park, Byung Yoon; Koh, Young Kown; Chun, Kwan Sik; Kim, Jhin Wung

    2000-05-01

    The geoscience research works are focused on the production of geologic basic data accompanying with the technical development of geology and hydrogeologic characterization. The lithology of the Korean peninsula consists of a complex structure of 29 rock types from Archean to Quaternary. The wide distribution of Mesozoic plutonic rock is an important consideration as a potential host rock allowing flexibility of siting. The recent tectonic activities are limited to localized particular area, which can be avoided by excluding in the early stage of siting. Three rock types such as plutonic rocks, crystalline gneisses and massive volcanic rocks were suggested as the preferred host rocks for the further study on HLW disposal system. This report contains grouping of regional faults, and on the distributional characteristics of faults and fractures(zones) in terms of lithological domain and tectonical provinces. The regional groundwater regime can be grouped into 3 regimes by tectonic setting and four groundwater regions based on an altitute. Groundwaters can be grouped by their chemistry and host rocks. The origin of groundwater was proposed by isotope ({sup 1}8O, {sup 2}H, {sup 1}3C, {sup 3}4S, {sup 8}7Sr, {sup 1}5N) studies and the residence time of groundwater was inferred from their tritium contents. Based on the geochemical and isotope characteristics, the geochemical evolutions of each types of groundwater were simulated using SOLVEQ/CHILLER and PHREEQC programs.

  11. Geologic environmental study

    International Nuclear Information System (INIS)

    Kim, Chun Soo; Bae, Dae Seok; Kim, Kyung Su; Park, Byung Yoon; Koh, Young Kown; Chun, Kwan Sik; Kim, Jhin Wung

    2000-05-01

    The geoscience research works are focused on the production of geologic basic data accompanying with the technical development of geology and hydrogeologic characterization. The lithology of the Korean peninsula consists of a complex structure of 29 rock types from Archean to Quaternary. The wide distribution of Mesozoic plutonic rock is an important consideration as a potential host rock allowing flexibility of siting. The recent tectonic activities are limited to localized particular area, which can be avoided by excluding in the early stage of siting. Three rock types such as plutonic rocks, crystalline gneisses and massive volcanic rocks were suggested as the preferred host rocks for the further study on HLW disposal system. This report contains grouping of regional faults, and on the distributional characteristics of faults and fractures(zones) in terms of lithological domain and tectonical provinces. The regional groundwater regime can be grouped into 3 regimes by tectonic setting and four groundwater regions based on an altitute. Groundwaters can be grouped by their chemistry and host rocks. The origin of groundwater was proposed by isotope ( 1 8O, 2 H, 1 3C, 3 4S, 8 7Sr, 1 5N) studies and the residence time of groundwater was inferred from their tritium contents. Based on the geochemical and isotope characteristics, the geochemical evolutions of each types of groundwater were simulated using SOLVEQ/CHILLER and PHREEQC programs

  12. Feasibility study of incore fission chamber application for neutron flux measurements on the NET blanket

    International Nuclear Information System (INIS)

    Bertalot, L.

    1987-01-01

    A feasibility study has been carried out on the use of in-core fission chambers as neutron diagnostic tools to perform neutron flux measurements on the blanket component of NET. The high neutron and gamma fluxes and the severe thermal-mechanical and magnetic conditions of the blanket structure have been taken into account in this analysis. Preliminary design criteria and specifications of an in-core detector are presented for NET application. A research and development programme is outlined which aims to obtain more information on the tecnological constraints arising from the severe conditions of the NET blanket

  13. A multi-chamber microfluidic intestinal barrier model using Caco-2 cells for drug transport studies

    DEFF Research Database (Denmark)

    Tan, Hsih-Yin; Trier, Sofie; Rahbek, Ulrik L

    2018-01-01

    with platinum wires, enabling parallel real-time monitoring of barrier integrity for the eight chambers. Additionally, the translucent porous Teflon membrane enabled optical monitoring of cell monolayers. The device was developed and tested with the Caco-2 intestinal model, and compared to the conventional...... through permeability studies of mannitol, dextran and insulin, alone or in combination with the absorption enhancer tetradecylmaltoside (TDM). The thiol-ene-based microchip material and electrodes were highly compatible with cell growth. In fact, Caco-2 cells cultured in the device displayed...

  14. A case study to estimate thermal conductivity of ABS in Cold Climate Chamber

    OpenAIRE

    Mughal, Umair Najeeb; Makarova, Marina; Virk, Muhammad Shakeel; Polanco Pinerez, Geanette

    2015-01-01

    Open Access (Romeo Green journal), publishers version / PDF may be used http://www.scirp.org/journal/wjet/ Non steady state thermal conductivity of ABS was estimated using an analytical approach in a Cold Climate Chamber at ?10?C and ?14?C. Two hollow cylinders of ABS of varying thickness were used to estimate the conductivity. The material was porous but the porosity was unknown. This paper is a case study to understand, if it is reasonable to estimate the thermal conductivity using th...

  15. Study of micro-strip gas ionisation chambers substrates for CMS experiment at LHC

    International Nuclear Information System (INIS)

    Pallares, A.

    1996-01-01

    High luminosity, expected interaction and dose rates of the future LHC collider require the development of micro-strips gas chambers. In addition to optimization of this new detector, this work is concerned with understanding of gain loss phenomena. Influence of the gas substrate is carefully analysed, as well as theoretical concepts concerning glasses and their behaviour under polarization and irradiation, and the consequence on detection operations.Electron spin resonance is used to study, in standard glass, creation of radiation induced defects which may be charged. (D.L.)

  16. Use of Clinical UV Chamber to Disinfect Dental Impressions: A Comparative Study.

    Science.gov (United States)

    Aeran, Himanshu; Sharma, Sakshi; Kumar, Varun; Gupta, Neelu

    2015-08-01

    Dental impressions are potential source of infection in a prosthodontic practice. Risk of transmission of infection through saliva, blood etc is considered as hazard for both dentist as well as dental auxiliary staff. A number of methods are currently employed for disinfecting the impressions which are technique sensitive and time consuming. This study focuses on disinfecting impression using dental UV chamber which is commonly employed for storing sterilized instruments. The aim of this invitro study was to evaluate the use of clinical UV chamber to disinfect various impression materials at different time intervals and its comparison with 2% glutaraldehyde using standard immersion technique. Total sample size of 180 specimens was taken from three different impression materials. The impressions were made from 30 dentulous subjects. A total of ten impressions were made for each impression material i.e. alginate, addition silicone and polyether impression material. Six punch samples were taken from each impression. Out of 6 punch sample, one was kept as control, second was disinfected by immersing in freshly prepared 2% glutaraldehyde solution for 10 minutes and remaining four were exposed to UV rays for 3 minutes, 6 minutes, 10 minutes and 15 minutes using dental UV chamber. Amount of disinfection achieved was evaluated by counting the colonies over the culture plates with the help of digital colony. The results showed that the mean CFUs for alginate were found to be i.e. 11797.40 ± 5989.73 (mean ± SD). The mean CFUs for addition silicone impression material was found 7095.40 with a standard deviation of 4268.83 and the mean CFUs for polyether impression material was found to be 2168.92 ± 1676 (mean ± SD). For alginate and addition silicone impression material, disinfection was achieved on exposure to UV rays for a period of 10 minutes. However, for polyether impression material 3 minutes of exposure to UV rays was sufficient to cause complete disinfection.

  17. Experimental Demonstration of the Formation of Liquid Brines under Martian Polar Conditions in the Michigan Mars Environmental Chamber

    Science.gov (United States)

    Fischer, Erik; Martinez, German; Elliott, Harvey; Borlina, Caue; Renno, Nilton

    2014-05-01

    Liquid water is one of the necessary ingredients for the development of life as we know it. The behavior of various liquid states of H2O such as liquid brine, undercooled liquid interfacial water, subsurface melt water and ground water [1] needs to be understood in order to address the potential habitability of Mars for microbes and future human exploration. It has been shown thermodynamically that liquid brines can exist under Martian polar conditions [2, 3]. We have developed the Michigan Mars Environmental Chamber (MMEC) to simulate the entire range of Martian surface and shallow subsurface conditions with respect to temperature, pressure, relative humidity, solar radiation and soil wetness at equatorial and polar latitudes. Our experiments in the MMEC show that deliquescence of NaClO4, Mg(ClO4)2 and Ca(ClO4)2 occurs diurnally under the environmental conditions of the Phoenix landing site when these salts get in contact with water ice. Since Phoenix detected these salts and water ice at the landing site, including frost formation, it is extremely likely that deliquescence occurs at the Phoenix landing site. By layering NaClO4, Mg(ClO4)2 or Ca(ClO4)2 on top of a pure water ice slab at 800 Pa and 190 K and raising the temperature stepwise across the eutectic temperature of the perchlorate salts, we observe distinct changes in the Raman spectra of the samples when deliquescence occurs. When crossing the eutectic temperatures of NaClO4 (236 K), Mg(ClO4)2 (205 K) and Ca(ClO4)2 (199 K) [4, 5], the perchlorate band of the Raman spectrum shows a clear shift from 953 cm-1 to 936 cm-1. Furthermore, the appearance of a broad O-H vibrational stretching spectrum between 3244 cm-1 and 3580 cm-1 is another indicator of deliquescence. This process of deliquescence occurs on the order of seconds when the perchlorate salt is in contact with water ice. On the contrary, when the perchlorate salt is only subjected to water vapor in the Martian atmosphere, deliquescence was not

  18. VUV photoemission studies of candidate Large Hadron Collider vacuum chamber materials

    Directory of Open Access Journals (Sweden)

    R. Cimino

    1999-06-01

    Full Text Available In the context of future accelerators and, in particular, the beam vacuum of the Large Hadron Collider (LHC, a 27 km circumference proton collider to be built at CERN, VUV synchrotron radiation (SR has been used to study both qualitatively and quantitatively candidate vacuum chamber materials. Emphasis is given to show that angle and energy resolved photoemission is an extremely powerful tool to address important issues relevant to the LHC, such as the emission of electrons that contributes to the creation of an electron cloud which may cause serious beam instabilities and unmanageable heat loads on the cryogenic system. Here we present not only the measured photoelectron yields from the proposed materials, prepared on an industrial scale, but also the energy and in some cases the angular dependence of the emitted electrons when excited with either a white light (WL spectrum, simulating that in the arcs of the LHC, or monochromatic light in the photon energy range of interest. The effects on the materials examined of WL irradiation and /or ion sputtering, simulating the SR and ion bombardment expected in the LHC, were investigated. The studied samples exhibited significant modifications, in terms of electron emission, when exposed to the WL spectrum from the BESSY Toroidal Grating Monochromator beam line. Moreover, annealing and ion bombardment also induce substantial changes to the surface thereby indicating that such surfaces would not have a constant electron emission during machine operation. Such characteristics may be an important issue to define the surface properties of the LHC vacuum chamber material and are presented in detail for the various samples analyzed. It should be noted that all the measurements presented here were recorded at room temperature, whereas the majority of the LHC vacuum system will be maintained at temperatures below 20 K. The results cannot therefore be directly applied to these sections of the machine until

  19. Smog chamber study on the evolution of fume from residential coal combustion.

    Science.gov (United States)

    Geng, Chunmei; Wang, Kun; Wang, Wei; Chen, Jianhua; Liu, Xiaoyu; Liu, Hongjie

    2012-01-01

    Domestic coal stoves are widely used in countryside and greenbelt residents in China for heating and cooking, and emit considerable pollutants to the atmosphere because of no treatment of their exhaust, which can result in deteriorating local air quality. In this study, a dynamic smog chamber was used to investigate the real-time emissions of gaseous and particulate pollutants during the combustion process and a static smog chamber was used to investigate the fume evolution under simulate light irradiation. The real-time emissions revealed that the total hydrocarbon (THC) and CO increased sharply after ignition, and then quickly decreased, indicating volatilization of hydrocarbons with low molecular weight and incomplete combustion at the beginning stage of combustion made great contribution to these pollutants. There was evident shoulder peak around 10 min combustion for both THC and CO, revealing the emissions from vitrinite combustion. Additionally, another broad emission peak of CO after 30 min was also observed, which was ascribed to the incomplete combustion of the inertinite. Compared with THC and CO, there was only one emission peak for NOx, SO2 and particular matters at the beginning stage of combustion. The fume evolution with static chamber simulation indicated that evident consumption of SO2 and NOx as well as new particle formation were observed. The consumption rates for SO2 and NOx were about 3.44% hr(-1) and 3.68% hr(-1), the new particle formation of nuclei particles grew at a rate of 16.03 nm/hr during the first reaction hour, and the increase of the diameter of accumulation mode particles was evident. The addition of isoprene to the diluted mixture of the fume could promote 03 and secondary particle formation.

  20. Study of Electromagnetic Interactions in the MicroBooNE Liquid Argon Time Projection Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Caratelli, David [Columbia U.

    2018-01-01

    This thesis presents results on the study of electromagnetic (EM) activity in the MicroBooNE Liquid Argon Time Projection Chamber (LArTPC) neutrino detector. The LArTPC detector technology provides bubble-chamber like information on neutrino interaction final states, necessary to perform precision measurements of neutrino oscillation parameters. Accelerator-based oscillation experiments heavily rely on the appearance channel ! e to make such measurements. Identifying and reconstructing the energy of the outgoing electrons from such interactions is therefore crucial for their success. This work focuses on two sources of EM activity: Michel electrons in the 10-50 MeV energy range, and photons from 0 decay in the 30-300 MeV range. Studies of biases in the energy reconstruction measurement, and energy resolution are performed. The impact of shower topology at different energies is discussed, and the importance of thresholding and other reconstruction effects on producing an asymmetric and biased energy measurement are highlighted. This work further presents a study of the calorimetric separation of electrons and photons with a focus on the shower energy dependence of the separation power.

  1. Experimental study of acoustic damping induced by gas-liquid scheme injectors in a combustion chamber

    International Nuclear Information System (INIS)

    Kim, Hak Soon; Sohn, Chae Hoon

    2007-01-01

    In a liquid rocket engine, acoustic damping induced by gas-liquid scheme injectors is studied experimentally for combustion stability by adopting linear acoustic test. In the previous work, it has been found that gas-liquid scheme injector can play a significant role in acoustic damping or absorption when it is tuned finely. Based on this finding, acoustic-damping characteristics of multi-injectors are intensively investigated. From the experimental data, it is found that acoustic oscillations are almost damped out by multi-injectors when they have the tuning length proposed in the previous study. The length corresponds to a half wavelength of the first longitudinal overtone mode traveling inside the injector with the acoustic frequency intended for damping in the chamber. But, new injector-coupled acoustic modes show up in the chamber with the injectors of the tuning length although the target mode is nearly damped out. And, appreciable frequency shift is always observed except for the case of the worst tuned injector. Accordingly, it is proposed that the tuning length is adjusted to have the shorter length than a half wavelength when these phenomena are considered

  2. Using the thermal diffusion cloud chamber to study the ion-induced nucleation by radon decay

    International Nuclear Information System (INIS)

    Wu, Yefei.

    1991-01-01

    Thermal diffusion cloud chamber is steady-state device and has been extensively used for nucleation research. In order to study the ion-induced nucleation by radon decay, a new chamber was designed with improved both upper and bottom plates, the system of circulating fluid, the gasketting, the temperature measurement and the insulation. An alternative method of using oxygen as carrier gas was examined. Therefore, the heavy carrier gas including nitrogen, oxygen, neon, argon and air can be used to study radon radiolysis-induced nucleation for the water or organic compounds in the TDCC. The effects of the pressure and temperature ranges on the density, supersaturation, temperature and partial pressure profile for the water-oxygen-helium in the TDCC have been examined. Based on the classical theory, the rate profile of ion-induced nucleation by radon decays was calculated and compared with the homogeneous nucleation. From measured indoor concentrations of Volatile Organic Compounds (VOC), thermodynamic theory models were used to assess the possibility that these compounds will form ultrafine particles in indoor air by ion-induced nucleation. The energy, number of molecules and equilibrium radius of clusters have been calculated based on Such and Thomson theories. These two sets of values have been compared. Ion cluster radii corresponding to 1--3 VOC molecules are in range of 3--5 x 10 -8 cm. 43 refs., 18 figs., 5 tabs

  3. Epidemiological and morphological studies of double-chambered right ventricle in dogs.

    Science.gov (United States)

    Fukushima, Ryuji; Tanaka, Ryou; Suzuki, Shuji; Hamabe, Rina; Machida, Noboru; Nakao, Shu; Saida, Yuto; Takashima, Kazuaki; Matsumoto, Hirotaka; Koyama, Hidekazu; Hirose, Hisashi; Yamane, Yoshihisa

    2011-10-01

    The double-chambered right ventricle (DCRV) is a rare congenital cardiac disease in dogs, and its detailed epidemiological and morphological features are not clearly understood. By investigating the profile, clinical signs, and characteristics of examination findings of eleven dogs with DCRV by means of a retrospective study, we attempted to clarify the epidemiology and morphology of the condition. The study group consisted of nine males and two females. Breeds included Pug (n=3), Miniature Dachshund (n=1), French Bull-dog (n=1), Shiba (n=1), and Retrievers (n=5). The attachment site of the anomalous muscular bundle was continuous with the cardiac apex in nine dogs, and it was attached to the right ventricle free wall in the other two dogs. In dogs with DCRV, at least one of the following conditions was present concurrently: congenital or acquired tricuspid valve regurgitation (TR), ventricular septal defect, and atrial septal defect. Also, the pressure difference between the two chambers increased over time, and progressive right-sided heart failure was observed. In summary, DCRV occurs in small breeds of dog as well as in large breeds of dog and it may be more prevalent in males. The existence of two types of DCRV in dogs was established. Dog with DCRVs will have a high incidence of concurrent cardiac abnormalities. Concurrent TR may be either congenital or acquired. DCRV is a congenital disorder, but the clinical condition progresses as the dog develops.

  4. Ussing Chamber

    NARCIS (Netherlands)

    Westerhout, J.; Wortelboer, H.; Verhoeckx, K.

    2015-01-01

    The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are

  5. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  6. UBM-guided chamber angle surgery for glaucoma management: an experimental study.

    Science.gov (United States)

    Dietlein, T S; Engels, B F; Jacobi, P C; Krieglstein, G K

    2003-04-01

    The aim of this experimental study was to investigate the potential of ultrasound bimicroscopy (UBM)-guided chamber angle surgery as an alternative or supplement to gonioscopy and intraocular microendoscopy for intraoperative control. In 15 porcine cadaver eyes, mechanical goniopuncture or punctual Er:YAG laser trabecular ablation was performed without operating microscope or gonioscopy, but with real-life ultrasound biomicroscopy monitoring with a 50 MHz transducer. Intraoperative localization of the microsurgical instruments and tissue-instrument contact were qualitatively evaluated. The instruments could be clearly visualized within the chamber angle and disturbing artefacts were only minimal when using mechanically fixed instruments in slow motion. Topographic localization, tissue contact, and penetration depth of the instruments entering the scleral were well illustrated as far as the technical resolution limits of UBM would allow. UBM can be used intraoperatively to monitor the correct manoeuvring of microsurgical instruments in selected ab interno procedures. Some adaptations and further modifications of the technique presented here will be necessary before UBM-guided surgery can be considered for clinical use in humans.

  7. Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla - a pilot study

    International Nuclear Information System (INIS)

    Knobelsdorff-Brenkenhoff, Florian von; Schulz-Menger, Jeanette; Frauenrath, Tobias; Hezel, Fabian; Prothmann, Marcel; Dieringer, Matthias A.; Niendorf, Thoralf; Renz, Wolfgang; Kretschel, Kerstin

    2010-01-01

    Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T. (orig.)

  8. Study of the collecting electrode material of an extrapolation chamber by Monte Carlo simulation

    International Nuclear Information System (INIS)

    Vedovato, Uly Pita; Santos, William S.; Perini, Ana Paula; Belinato, Walmir

    2017-01-01

    In this work, the influence of different materials of the collecting electrode on the response of an extrapolation ionization chamber, was evaluated. This ionization chamber was simulated with the MCNP-4C Monte Carlo code and the spectrum of a standard diagnostic radiology beam (RQR5) was utilized. The different results are due to interactions of photons with different materials of the collecting electrode contributing with different values of energy deposited in the sensitive volume of the ionization chamber, which depends on the atomic number of the evaluated materials. The material that presented the least influence was graphite, the original constituent of the ionization chamber. (author)

  9. CLINICAL STUDY OF POSTERIOR CHAMBER PHAKIC IOL PLACEMENT IN MYOPIC PATIENTS

    Directory of Open Access Journals (Sweden)

    Ashok Kumar P

    2017-02-01

    Full Text Available BACKGROUND The aim of this study was to determine the safety and efficacy of posterior chamber phakic IOL in Myopic patients. MATERIALS AND METHODS This prospective interventional study included 50 eyes of 50 patients with myopia. Patients of age more than 18 yrs. Stable refraction, Myopia, Mild to Moderate keratoconus and absence of any ocular pathology and any history of ocular surgeries were included in this study. Prior to starting treatment certain parameters like visual acuity, AC depth, Iridocorneal Angle Aperture, Endothelial cell count, Central corneal thickness and IOP were considered. Intervention- Implantation of the phakic IOL. Main outcome Measures- Uncorrected Visual Acuity (UCVA, best spectacle corrected visual acuity (BSCVA, AS OCT AC depthbetween endothelium and phakic IOL, IOP and Endothelial cell count were recorded. RESULTS Postoperative examinations conducted at day 1, day 3, after 1 week, 1 month and after 3 months .out of 50 patients, 4 patients had striate keratopathy, 2 patients had shallow ac during immediate post-operative period. During the postoperative follow up 10 patients had BCVA of 6/9-6/6 (20%, 14 patients had 6/9-6/12 (28%, 24 patients had 6/12-6/24(48% and remaining 2 patients had <6/24 which was better than their preoperative uncorrected visual acuity. CONCLUSION Based on this prospective clinical study and on comparison with other clinical studies posterior chamber phakic IOL corrective procedures are safe and effective for treatment of myopia. It also shows that it can provide sharp and clear vision in 96% of our study population. It does not induce dry eye syndrome as in other refractive surgeries. Short term complications like endothelial damage, angle closure glaucoma, iritis, anterior capsule injury/lens changes were not encountered during our study. But still long term follow up is required to confirm long term safety of the implant.

  10. A Structural Study of Escherichia coli Cells Using an In Situ Liquid Chamber TEM Technology

    Directory of Open Access Journals (Sweden)

    Yibing Wang

    2015-01-01

    Full Text Available Studying cell microstructures and their behaviors under living conditions has been a challenging subject in microbiology. In this work, in situ liquid chamber TEM was used to study structures of Escherichia coli cells in aqueous solutions at a nanometer-scale resolution. Most of the cells remained intact under electron beam irradiation, and nanoscale structures were observed during the TEM imaging. The analysis revealed structures of pili surrounding the E. coli cells; the movements of the pili in the liquid were also observed during the in situ tests. This technology also allowed the observation of features of the nucleoid in the E. coli cells. Overall, in situ TEM can be applied as a valuable tool to study real-time microscopic structures and processes in microbial cells residing in native aqueous solutions.

  11. Study of 2 proton radioactivity of 54Zn with a time projection chamber

    International Nuclear Information System (INIS)

    Ascher, P.

    2011-11-01

    The study of nuclei at the proton drip-line is a recent and efficient tool to prove the nuclear structure far from stability. In particular, the two-proton radioactivity phenomenon predicted in 1960 has been discovered in 2002. This work concerns an experiment performed at GANIL, in order to study the two-proton radioactivity of 54 Zn with a time projection chamber, developed for the individual detection of each proton and the reconstruction of their tracks in three dimensions. The data analysis allowed to determine the correlations in energy and angle between the two protons. They have been compared to a theoretical model, which takes into account the dynamics of the emission, giving information about the structure of the emitter. However, due to the very low statistics, the interpretation of the results is limited but these results open very interesting prospects for further studies of nuclei at the limits of the existence. (author)

  12. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. Simulation study of the photon quality correction factors of ionization chambers for FiR 1 epithermal neutron beam

    International Nuclear Information System (INIS)

    Koivunoro, H.; Uusi-Simola, J.; Savolainen, S.; Kotiluoto, P.; Auterinen, I.; Kosunen, A.

    2006-01-01

    At FiR 1 BNCT facility in Finland, neutron-insensitive Mg(Ar) ionization chambers are used for photon dose measurements in an epithermal neutron beam. Previously, photon sensitivity factors for the chamber for the measurements in a water phantom in FiR 1 beam have been determined experimentally from measurements in 60 Co gamma and in a 6 MV clinical accelerator photon beams. However, the response of the ionization chamber in a water phantom depends on energy spectrum and angle of the photons and the secondary electrons created inside the phantom and may differ depending on type of the irradiation source (accelerator vs. an epithermal neutron beam). Also, the experimental sensitivity factor does not take into account the possible perturbations in the photon production in phantom caused by the ionization chamber materials. Therefore, it is necessary to determine the photon quality correction factors (k Qγ ) for the Mg(Ar) chamber at the FiR 1 beam through computer simulations. In this study, the k Qγ factors have been determined for Mg(Ar) chamber from Monte Carlo calculations of absorbed photon dose at two depths in a water phantom using MCNP code. The k qγ factors obtained with this method are compared to the sensitivity factors determined with measurements in an accelerator photon beam and to the k Qγ factors published previously. (author)

  15. Multigap resistive plate chambers for EAS study in the EEE Project

    CERN Document Server

    An, S; Badalà, A; Zichichi, A

    2007-01-01

    The EEE (Extreme Energy Events) Project, conceived by its leader Antonino Zichichi, is an experiment to study very high-energetic air showers (EAS) through the detection of the shower's muon component using a network of tracking detectors, installed in Italian high schools. The single tracking telescope is composed of three large area () Multi-gap Resistive Plate Chambers (MRPCs). The data collected by the telescopes will be used for studies of air showers and also for the search of time correlations between sites which are far apart. The first telescope, recently installed in the Liceo B. Touschek in Grottaferrata (Rome), is successfully running, and other telescopes are going to be installed in a short time in other towns, opening up the way for the first search of long-distance coincidences over a total area of .

  16. Hertelendi Laboratory of Environmental Studies

    International Nuclear Information System (INIS)

    Svingor, E.; Molnar, M.; Palcsu, L.; Futo, I.; Rinyu, L.; Mogyorosi, M.; Major, Z.; Bihari, A.; Vodila, G.; Janovics, R.; Papp, L.; Major, I.

    2010-01-01

    1. Introduction. The Hertelendi Laboratory for Environmental Studies (HEKAL) belongs to the Section of Environmental and Earth Sciences. It is a multidisciplinary laboratory dedicated to environmental research, to the development of nuclear analytical methods and to systems technology. During its existence of more than 15 years it has gained some reputation as a prime laboratory of analytical techniques, working with both radio- and stable isotopes. It has considerable expertise in isotope concentration measurements, radiocarbon dating, tritium measurements, in monitoring radioactivity around nuclear facilities and in modelling the movement of radionuclides in the environment. Many of its projects are within the scope of interest of the Paks Nuclear Power Plant. Our research activity is mainly concerned with the so-called environmental isotopes. This term denotes isotopes, both stable and radioactive, that are present in the natural environment either as a result of natural processes or of human activities. In environmental research isotopes are generally applied either as tracers or as age indicators. An ideal tracer is defined as a substance that behaves in the system studied exactly as the material to be traced as far as the examined parameters are concerned, but has at least one property that distinguishes it from the traced material. The mass number of an isotope is such an ideal indicator. In 2007 the laboratory assumed the name of Dr. Ede Hertelendi to honour the memory of the reputed environmental physicist who founded the group and headed it for many years. The current core of the laboratory staff is made up of his pupils and coworkers. This team was like a family to him. The group owes it to his fatherly figure that it did not fall apart after his death, but advanced with intense work and tenacity during the last decade. One of his first pupils, Mihaly Veres returned to the laboratory as a private entrepreneur and investor in 2005, and in the framework of

  17. Efficiency profile method to study the hit efficiency of drift chambers

    International Nuclear Information System (INIS)

    Abyzov, A.; Bel'kov, A.; Lanev, A.; Spiridonov, A.; Walter, M.; Hulsbergen, W.

    2002-01-01

    A method based on the usage of efficiency profile is proposed to estimate the hit efficiency of drift chambers with a large number of channels. The performance of the method under real conditions of the detector operation has been tested analysing the experimental data from the HERA-B drift chambers

  18. Study of the performance of a 4 π γ ionisation chamber

    International Nuclear Information System (INIS)

    Engelmann, J.J.

    1960-01-01

    Description of a well-type γ chamber for routine measurements of sources between 1 μcurie and 1 curie. Approximate calculation of some geometrical parameters by which the zone of constant sensitivity may be increased. Calculation of the sensitivity of such a chamber and comparison with the experimental results. (author) [fr

  19. Ionization chamber

    International Nuclear Information System (INIS)

    1977-01-01

    An improved ionization chamber type X-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is placed next to the anode and is maintained at a voltage intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting towards the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  20. Ionization chambers

    International Nuclear Information System (INIS)

    Boag, J.W.

    1987-01-01

    Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed

  1. Climatic chamber ergometer

    CSIR Research Space (South Africa)

    Atkins, AR

    1968-01-01

    Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...

  2. Evaluation of 1,3,5 trimethylbenzene degradation in the detailed tropospheric chemistry mechanism, MCMv3.1, using environmental chamber data

    Directory of Open Access Journals (Sweden)

    A. Metzger

    2008-11-01

    Full Text Available The degradation mechanism of 1,3,5-trimethyl- benzene (TMB as implemented in the Master Chemical Mechanism version 3.1 (MCM was evaluated using data from the environmental chamber at the Paul Scherrer Institute. The results show that the MCM provides a consistent description of the photo-oxidation of TMB/NOx mixtures for a range of conditions. In all cases the agreement between the measurement and the simulation decreases with decreasing VOC-NOx ratio and in addition with increasing precursor concentration. A significant underestimation of the decay rate of TMB and thus underestimation of reactivity in the system, consistent with results from previous appraisals of the MCM, was observed.

    Much higher nitrous acid (HONO concentrations compared to simulations and expected from chamber characterization experiments were measured during these smog chamber experiments. A light induced NO2 to HONO conversion at the chamber walls is suggested to occur. This photo-enhanced NO2 to HONO conversion with subsequent HONO photolysis enhances the reactivity of the system. After the implementation of this reaction in the model it describes the decay of TMB properly. Nevertheless, the model still over-predicts ozone at a later stage of the experiment. This can be attributed to a too slow removal of NO2. It is also shown that this photo-enhanced HONO formation is not restricted to TMB photo-oxidation but also occurs in other chemical systems (e.g. α-pinene. However, the influence of HONO as a source of OH radicals is less important in these more reactive systems and therefore the importance of the HONO chemistry is less obvious.

  3. [Effects of elevated ozone on Pinus armandii growth: a simulation study with open-top chamber].

    Science.gov (United States)

    Liu, Chang-Fu; Liu, Chen; He, Xing-Yuan; Ruan, Ya-Nan; Xu, Sheng; Chen, Zhen-Ju; Peng, Jun-Jie; Li, Teng

    2013-10-01

    By using open-top chamber (OTC) and the techniques of dendrochronology, this paper studied the growth of Pinus armandii under elevated ozone, and explored the evolution dynamics and adaptation mechanisms of typical forest ecosystems to ozone enrichment. Elevated ozone inhibited the stem growth of P. armandii significantly, with the annual growth of the stem length and diameter reduced by 35.0% and 12.9%, respectively. The annual growth of tree-ring width and the annual ring cells number decreased by 11.5% and 54.1%, respectively, but no significant change was observed in the diameter of tracheid. At regional scale, the fluctuation of ozone concentration showed significant correlation with the variation of local vegetation growth (NDVI).

  4. A steady-state continuous flow chamber for the study of daytime and nighttime chemistry under atmospherically relevant NO levels

    Science.gov (United States)

    Zhang, Xuan; Ortega, John; Huang, Yuanlong; Shertz, Stephen; Tyndall, Geoffrey S.; Orlando, John J.

    2018-05-01

    Experiments performed in laboratory chambers have contributed significantly to the understanding of the fundamental kinetics and mechanisms of the chemical reactions occurring in the atmosphere. Two chemical regimes, classified as high-NO vs. zero-NO conditions, have been extensively studied in previous chamber experiments. Results derived from these two chemical scenarios are widely parameterized in chemical transport models to represent key atmospheric processes in urban and pristine environments. As the anthropogenic NOx emissions in the United States have decreased remarkably in the past few decades, the classic high-NO and zero-NO conditions are no longer applicable to many regions that are constantly impacted by both polluted and background air masses. We present here the development and characterization of the NCAR Atmospheric Simulation Chamber, which is operated in steady-state continuous flow mode for the study of atmospheric chemistry under intermediate NO conditions. This particular chemical regime is characterized by constant sub-ppb levels of NO and can be created in the chamber by precise control of the inflow NO concentration and the ratio of chamber mixing to residence timescales. Over the range of conditions achievable in the chamber, the lifetime of peroxy radicals (RO2), a key intermediate from the atmospheric degradation of volatile organic compounds (VOCs), can be extended to several minutes, and a diverse array of reaction pathways, including unimolecular pathways and bimolecular reactions with NO and HO2, can thus be explored. Characterization experiments under photolytic and dark conditions were performed and, in conjunction with model predictions, provide a basis for interpretation of prevailing atmospheric processes in environments with intertwined biogenic and anthropogenic activities. We demonstrate the proof of concept of the steady-state continuous flow chamber operation through measurements of major first-generation products

  5. A steady-state continuous flow chamber for the study of daytime and nighttime chemistry under atmospherically relevant NO levels

    Directory of Open Access Journals (Sweden)

    X. Zhang

    2018-05-01

    Full Text Available Experiments performed in laboratory chambers have contributed significantly to the understanding of the fundamental kinetics and mechanisms of the chemical reactions occurring in the atmosphere. Two chemical regimes, classified as high-NO vs. zero-NO conditions, have been extensively studied in previous chamber experiments. Results derived from these two chemical scenarios are widely parameterized in chemical transport models to represent key atmospheric processes in urban and pristine environments. As the anthropogenic NOx emissions in the United States have decreased remarkably in the past few decades, the classic high-NO and zero-NO conditions are no longer applicable to many regions that are constantly impacted by both polluted and background air masses. We present here the development and characterization of the NCAR Atmospheric Simulation Chamber, which is operated in steady-state continuous flow mode for the study of atmospheric chemistry under intermediate NO conditions. This particular chemical regime is characterized by constant sub-ppb levels of NO and can be created in the chamber by precise control of the inflow NO concentration and the ratio of chamber mixing to residence timescales. Over the range of conditions achievable in the chamber, the lifetime of peroxy radicals (RO2, a key intermediate from the atmospheric degradation of volatile organic compounds (VOCs, can be extended to several minutes, and a diverse array of reaction pathways, including unimolecular pathways and bimolecular reactions with NO and HO2, can thus be explored. Characterization experiments under photolytic and dark conditions were performed and, in conjunction with model predictions, provide a basis for interpretation of prevailing atmospheric processes in environments with intertwined biogenic and anthropogenic activities. We demonstrate the proof of concept of the steady-state continuous flow chamber operation through measurements of major first

  6. Environmental Studies and Utilitarian Ethics

    Science.gov (United States)

    Wolff, Brian G.

    2009-01-01

    Environmental ethicists have focused much attention on the limits of utilitarianism and have generally defined "environmental ethics" in a manner that treats utilitarian environmental ethics as an oxymoron. This is unfortunate because utilitarian ethics can support strong environmental policies, and environmental ethicists have not yet produced a…

  7. Morphological studies on the Gaseous Chambers of the African-Catfish (Clarias gariepinus

    Directory of Open Access Journals (Sweden)

    Eman A. Eshra

    2015-04-01

    Full Text Available This study aimed to find out the morpho-functional correlations of supra-branchial gaseous chambers (SC and gas bladder (GB in Clarias gariepinus. Gross, and Histological observations were made on ten different ontogenetic stages ranged from 10 mm SL (Standard length to 100 mm SL, and mature fish 330 mm-333 mm SL. Computed tomography (CT was performed on five mature fishes at 130 K Volt and 80 Ma, different CT windows were adjusted as follows: Soft tissue (WL: 40, WW: 300, Bone (2000: 400, and Air-chambers (-600:1200. Each SC lodged mid-constricted membranous sac, communicated to gill cavity via single opening. The GB was an oval sac surrounded by incomplete bony capsule, it touched the skin laterally, otic capsule medially and SC anteriorly. The SC membrane was three layered with a gill like mucosa (respiratory mucosa; GB has an inner layer of simple squamous epithelium and an outer layer of dense irregular connective tissue. Collectively, the larval stages were adult like, but differ in proportions; in stages from 10 to 26 mm, SC adventitia was ill defined or absent and SC musculosa was well developed relatively to the total thickness of the membrane. In CT images, there was a clear communication between the otic capsule and GB at the level of anterior-medial fissures of complex vertebra; disc–shaped fat pads appeared as hypodense bilateral areas dorso-medial to GB and caudo-posterior to SC. Results Concluded that GB and SC had an accessory auditory role related to their anatomical structure, position and communications.

  8. Program and performance characteristics of the environmental chambers during a long-term experiment with Norway spruce trees exposed to ozone, acid mist, and frost

    Energy Technology Data Exchange (ETDEWEB)

    Payer, H D; Blank, L W; Eisenmann, T; Runkel, K H; Bosch, C

    1986-09-01

    This paper describes the climatic and pollutant conditions simulated in the new environmental chambers of the GSF (Payer et al. 1986) during the course of the first (five-month) experiment. This so-called 'pilot-project' was also used to assess the technical performance of this new research facility during realistic experimental conditions. The factorial design with 16 groups analyzed the effects of i) normal winter temperatures vs. an episode of severe frost, ii) low vs. raised ozone concentrations, iii) misting with water of pH 5.6 vs. water of pH 3.0, and iiii) fertilized vs. unfertilized soil. The climatic conditions and ozone levels applied were based on longterm field measurements from the higher regions of the Bavarian forest in order to simulate realistic diurnal and seasonal variations as observed at a site affected by severe forest decline. The main characteristics of this exposure program are outlined, and an assessment of the technical performance of the environmental chambers is given in this paper.

  9. 25 CFR 211.7 - Environmental studies.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Environmental studies. 211.7 Section 211.7 Indians BUREAU... DEVELOPMENT General § 211.7 Environmental studies. (a) The Secretary shall ensure that all environmental studies are prepared as required by the National Environmental Policy Act of 1969 (NEPA) and the...

  10. 25 CFR 225.24 - Environmental studies.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Environmental studies. 225.24 Section 225.24 Indians... SOLID MINERALS AGREEMENTS Minerals Agreements § 225.24 Environmental studies. (a) The Secretary shall ensure that all environmental studies are prepared as required by the National Environmental Policy Act...

  11. A new pressure chamber to study the biosynthetic response of articular cartilage to mechanical loading.

    Science.gov (United States)

    Steinmeyer, J; Torzilli, P A; Burton-Wurster, N; Lust, G

    1993-01-01

    A prototype chamber was used to apply a precise cyclic or static load on articular cartilage explants under sterile conditions. A variable pressure, pneumatic controller was constructed to power the chamber's air cylinder, capable of applying, with a porous load platen, loads of up to 10 MPa at cycles ranging from 0 to 10 Hz. Pig articular cartilage explants were maintained successfully in this chamber for 2 days under cyclic mechanical loading of 0.5 Hz, 0.5 MPa. Explants remained sterile, viable and metabolically active. Cartilage responded to this load with a decreased synthesis of fibronectin and a small but statistically significant elevation in proteoglycan content. Similar but less extensive effects on fibronectin synthesis were observed with the small static load (0.016 MPa) inherent in the design of the chamber.

  12. Radiation aging studies of CO2 hydrocarbon mixtures for the SLD drift chamber

    International Nuclear Information System (INIS)

    Venuti, J.P.; Chadwick, G.B.

    1988-10-01

    The SLD drift chamber requires a 'slow' drifting gas and low diffusion to allow wave form digitization. CO 2 provides this but requires an admixture of a quencher to provide more gain. A test chamber with an 8 sense wire cell, such as will appear in the final chamber, was exposed to an x-ray tube while containing a variety of binary admixtures of Co 2 : 8% isobutane, 8% ethane, and 2% isopropanol. It was determined that adding small fractions of water (≤0.66%) or isopropanol (1--2%) to the Co 2 : 8% ethane, or 8% isobutane extended the useful life of the chamber so that integrated charge collections of /approximately/1 C/cm are permissible. Results and discussions are presented. 10 refs., 7 figs., 1 tab

  13. Chamber with punches made from polycrystal cubic boron nitrides for Moessbauer study at high hydrostatic pressure

    International Nuclear Information System (INIS)

    Kapitanov, E.V.; Yakovlev, E.N.

    1978-01-01

    The design of a high hydrostatic pressure chamber with polycrystallic boron nitride dies weakly absorbing gamma radiation with energies of more than 14 keV is described. The use of this material permits to investigate single- and polycrystal bodies using the Moessbauer effect when the geometry of the experiment remains unchanged and the hydrostatic pressure is up to 70 kbar. The basic units of the chamber are a teflon capsule placed in a container made of a pressed boron and epoxide resin mixture, electric inputs and a die of polycrystal cubic boron nitride. The pressure is transferred to the sample tested through a liquid (petrol or the 4 to 1 mixture of methanole and ethanole) which does not become solid at a pressure below 37 kbar. Basic dimensions of the chamber are given and the dependence of the pressure in the capsule on the force applied to the chamber is also presented

  14. A study of energy resolution in a gridded ionization chamber filled with tetramethylsilane and tetramethylgermanium

    International Nuclear Information System (INIS)

    Hara, H.; Ohnuma, H.; Hoshi, Y.; Yuta, H.; Abe, K.; Suekane, F.; Neichi, M.; Nakajima, T.; Masuda, K.

    1998-01-01

    The energy resolutions of 976 keV conversion electrons from a 207 Bi source are measured in a gridded ionization chamber filled with tetramethylsilane (TMS) and tetramethylgermanium (TMG), and are found to be about 5.7 and 5.5% (rms) for TMS and TMG, respectively. We also deduce a simple method of estimating the electron lifetime using a gridded ionization chamber. The electron lifetime, free ion yield and thermalization length for these liquids are measured by this simple method

  15. Development of a Configurable Growth Chamber with a Computer Vision System to Study Circadian Rhythm in Plants

    Directory of Open Access Journals (Sweden)

    Marcos Egea-Cortines

    2012-11-01

    Full Text Available Plant development is the result of an endogenous morphogenetic program that integrates environmental signals. The so-called circadian clock is a set of genes that integrates environmental inputs into an internal pacing system that gates growth and other outputs. Study of circadian growth responses requires high sampling rates to detect changes in growth and avoid aliasing. We have developed a flexible configurable growth chamber comprising a computer vision system that allows sampling rates ranging between one image per 30 s to hours/days. The vision system has a controlled illumination system, which allows the user to set up different configurations. The illumination system used emits a combination of wavelengths ensuring the optimal growth of species under analysis. In order to obtain high contrast of captured images, the capture system is composed of two CCD cameras, for day and night periods. Depending on the sample type, a flexible image processing software calculates different parameters based on geometric calculations. As a proof of concept we tested the system in three different plant tissues, growth of petunia- and snapdragon (Antirrhinum majus flowers and of cladodes from the cactus Opuntia ficus-indica. We found that petunia flowers grow at a steady pace and display a strong growth increase in the early morning, whereas Opuntia cladode growth turned out not to follow a circadian growth pattern under the growth conditions imposed. Furthermore we were able to identify a decoupling of increase in area and length indicating that two independent growth processes are responsible for the final size and shape of the cladode.

  16. Cloud Chamber

    DEFF Research Database (Denmark)

    Gfader, Verina

    Cloud Chamber takes its roots in a performance project, titled The Guests 做东, devised by Verina Gfader for the 11th Shanghai Biennale, ‘Why Not Ask Again: Arguments, Counter-arguments, and Stories’. Departing from the inclusion of the biennale audience to write a future folk tale, Cloud Chamber......: fiction and translation and translation through time; post literacy; world picturing-world typing; and cartographic entanglements and expressions of subjectivity; through the lens a social imaginary of worlding or cosmological quest. Art at its core? Contributions by Nikos Papastergiadis, Rebecca Carson...

  17. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  19. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  20. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. Case Studies of Environmental Visualization

    Directory of Open Access Journals (Sweden)

    Panagiotis Patlakas

    2017-09-01

    Full Text Available The performance gap between simulation and reality has been identified as a major challenge to achieving sustainability in the Built Environment. While Post-Occupancy Evaluation (POE surveys are an integral part of better understanding building performance, and thus addressing this issue, the importance of POE remains relatively unacknowledged within the wider Built Environment community. A possible reason that has been highlighted is that POE survey data is not easily understood and utilizable by non-expert stakeholders, including designers. A potential method by which to address this is the visualization method, which has well established benefits for communication of big datasets. This paper presents two case studies where EnViz (short for “Environmental Visualization”, a prototype software application developed for research purposes, was utilized and its effectiveness tested via a range of analysis tasks. The results are discussed and compared with those of previous work that utilized variations of the methods presented here. The paper concludes by presenting the lessons drawn from the five-year period of EnViz, emphasizing the potential of environmental visualization for decision support in environmental design and engineering for the built environment, and suggests directions for future development.

  2. Study of gas mixtures and ageing of the multigap resistive plate chamber used for the ALICE TOF

    CERN Document Server

    Akindinov, A; Anselmo, F; Antonioli, P; Basile, M; Cara Romeo, G; Cifarelli, Luisa; Cindolo, F; Cosenza, F; D'Antone, I; De Caro, A; De Pasquale, S; Di Bartolomeo, A; Fusco-Girard, M; Golovine, V; Guerzoni, M; Guida, M; Hatzifotiadou, D; Kaidalov, A B; Kim, D H; Kim, D W; Kisselev, S M; Laurenti, G; Lioublev, E; Lee, K; Lee, S C; Luvisetto, M L; Margotti, A; Martemyanov, A N; Massera, F; Meneghini, S; Michinelli, R; Nania, R; Otiougova, P; Pancaldi, G; Pesci, A; Pilastrini, R; Pinazza, O; Polozov, P A; Rizzi, M; Scapparone, E; Scioli, G; Sellitto, S B; Semeria, F; Serra, S; Smirnitsky, A V; Tchoumakov, M M; Ugolini, E; Usenko, E; Valenti, G; Voloshin, K G; Williams, M C S; Zagreev, B V; Zampolli, C; Zichichi, A; Zucchini, A; Zuffa, M

    2004-01-01

    We present in this paper a study of the ALICE-TOF Multigap Resistive Plate Chamber (MRPC) performance by using several gas mixtures. We also present a search for possible ageing effects, by studying two MRPCs irradiated at the CERN Gamma Irradiation Facility.

  3. Feasibility study for the development of a Dose Calibrator with a well ionization chamber

    International Nuclear Information System (INIS)

    Arista Romeu, E. J.

    2015-01-01

    Dose calibrators are intended for the metrological assurance of medical diagnostic studies in which radiopharmaceuticals are used. It is the final link in the national system of standards to ensure quality control and the radiation safety of the dose administered to patients while using these nuclear techniques. The wide utilization of radiopharmaceuticals in our country in several modules of nuclear medicine and other laboratories where radio-isotopic preparations are used, as well as the existence of the National Center of Isotopes to produce them determine the necessity of national production of dose calibration equipment. In this paper, it is presented the result of a feasibility study to develop a dose calibrator with a well-type ionization chamber for nuclear medicine services of the National Health System with gamma camera. It is specifically intended to contribute to monitor and control the activity of the prepared samples to be administered to patients under studies with gamma cameras to ensure compliance with the current requirements of quality and radiation safety. (Author)

  4. Laboratory and Cloud Chamber Studies of Formation Processes and Properties of Atmospheric Ice Particles

    Science.gov (United States)

    Leisner, T.; Abdelmonem, A.; Benz, S.; Brinkmann, M.; Möhler, O.; Rzesanke, D.; Saathoff, H.; Schnaiter, M.; Wagner, R.

    2009-04-01

    The formation of ice in tropospheric clouds controls the evolution of precipitation and thereby influences climate and weather via a complex network of dynamical and microphysical processes. At higher altitudes, ice particles in cirrus clouds or contrails modify the radiative energy budget by direct interaction with the shortwave and longwave radiation. In order to improve the parameterisation of the complex microphysical and dynamical processes leading to and controlling the evolution of tropospheric ice, laboratory experiments are performed at the IMK Karlsruhe both on a single particle level and in the aerosol and cloud chamber AIDA. Single particle experiments in electrodynamic levitation lend themselves to the study of the interaction between cloud droplets and aerosol particles under extremely well characterized and static conditions in order to obtain microphysical parameters as freezing nucleation rates for homogeneous and heterogeneous ice formation. They also allow the observation of the freezing dynamics and of secondary ice formation and multiplication processes under controlled conditions and with very high spatial and temporal resolution. The inherent droplet charge in these experiments can be varied over a wide range in order to assess the influence of the electrical state of the cloud on its microphysics. In the AIDA chamber on the other hand, these processes are observable under the realistic dynamic conditions of an expanding and cooling cloud- parcel with interacting particles and are probed simultaneously by a comprehensive set of analytical instruments. By this means, microphysical processes can be studied in their complex interplay with dynamical processes as for example coagulation or particle evaporation and growth via the Bergeron - Findeisen process. Shortwave scattering and longwave absorption properties of the nucleating and growing ice crystals are probed by in situ polarised laser light scattering measurements and infrared extinction

  5. Radiation studies on resistive bulk-micromegas chambers at the CERN Gamma Irradiation Facility

    CERN Document Server

    Alvarez Gonzalez, Barbara; Camerlingo, Maria Teresa; Farina, Edoardo; Iengo, Paolo; Longo, Luigi; Samarati, Jerome; Sidiropoulou, Ourania; Wotschack, Joerg

    2018-01-01

    With the growing diffusion of resistive Micromegas detectors in HEP experiments the study of long-term aging behaviour is becoming more and more relevant. Two resistive bulk-Micromegas detectors were installed in May 2015 at the CERN Gamma Irradiation Facility and exposed to an intense gamma irradiation with the aim to study the detector behavior under high irradiation and the long-term aging. The detectors have an active area of 10 × 10 cm 2 , readout strip pitch of 400 μ m , amplification gap of 128 μ m and drift gap of 5 mm. The desired accumulated charge of more than 0.2 C/cm 2 has been reached for both chambers, equivalent to 10 years of HL-LHC operation. The efficiency, amplification, and resolution of the Micromegas after this long-term irradiation period is compared with the performance of a non irradiated detector. In addition, the latest results of the measured particle rate as a function of the amplification voltage is presented and compared with those obtained in 2015.

  6. Study of the design variables for a wet-chamber gas meter prototype (MGCH)

    International Nuclear Information System (INIS)

    Patino, Carlos Hernando; Romero, Luis Said; Quiroga, Jabid

    2004-01-01

    This paper established the most important variables and their correlation that affect design and operation of wet-chamber gas meter (MGCH), focused on the gas pressure difference along the meter and the sealing-liquid level. In order to study variable behavior a simulation was carried out based on computational systems The mathematical model developed was built taking into account common features in present wet test gas meter as their internal configuration. Therefore, this work can be understood as a general analysis and its conclusions can be extended to whichever meter of this type. Software was developed to facilitate the analysis of the variables involved in this physical process; besides the drum sizing was modeling using CAD software. As a result of this investigation, theoretical basis were established for the analyzing and designing of a MGCH meter, as a previous phase to the construction and evaluation of the prototype. Uncertainty analysis of each variable implicates in this model was beyond the scope of this study

  7. Distribution of radioactively labelled myobacterium tuberculosis (65Zn, 35S-BCG) after injection into the anterior chamber. Studies in rabbits with and without anterior chamber sensitisation

    International Nuclear Information System (INIS)

    Tabillion, M.

    1985-01-01

    The rabbit model was used to study the behaviour of antigens in the eye as well as their spread to extraocular regions. Prior to the investigations, a test dose of 35 S-labelled and 65 Zn-labelled BCG (Bacille Calmette Guerin) had been injected into the anterior chamber of the eyes of sensitised and non-sensitised rabbits. The percentage of BCG escaping from the aqueous humor and iris was mostly not dependent of the test dose given, nor did the rate of its spread show any relation to the occurrence of an antigen-antibody reaction. On the 32nd day p.i., there were still acid-resisting rods in the uvea, which could be proven by histological examination. As shown by the levels of activity in the iris and ciliary body, the bacteria appear to migrate mostly to these organs and, in the second place, to the choroid membrane. The spread of bacteria in previously sensitised rabbits was not different from the observed in non-sensitised animals. Theories claiming that more antigens are formed in sensitised tissue as compared to non-sensitised tissue cannot be confirmed by the findings revealed here. (TRV) [de

  8. Tritons for the study of the charge-exchange reactions with the LHE streamer chamber: status and some possibilities

    International Nuclear Information System (INIS)

    Avramenko, S.A.; Belikov, Yu.A.; Golokhvastov, A.I.; Kirillov, A.D.; Khorozov, S.A.; Komolov, L.N.; Lukstin'sh, Yu.; Rukoyatkin, P.A.

    1997-01-01

    The 6 and 9 GeV/c secondary tritons, produced in the 4 He+A→ 3 H+X reaction, were used to study the charge-exchange reactions using a streamer chamber in magnetic field. The triton formation schemes, the beam parameters achieved as well as a way to reduce the beam momentum spread are given in the paper

  9. DEVELOPMENT AND USE OF A PARALLEL-PLATE FLOW CHAMBER FOR STUDYING CELLULAR ADHESION TO SOLID-SURFACES

    NARCIS (Netherlands)

    VANKOOTEN, TG; SCHAKENRAAD, JM; VANDERMEI, HC; BUSSCHER, HJ

    A parallel-plate flow chamber is developed in order to study cellular adhesion phenomena. An image analysis system is used to observe individual cells exposed to flow in situ and to determine area, perimeter, and shape of these cells as a function of time and shear stress. With this flow system the

  10. Double beta decays studied by β-γ spectroscopy with a drift chamber

    International Nuclear Information System (INIS)

    Okada, K.; Ejiri, H.; Shibata, T.

    1986-01-01

    A large scale ultra low background β-γ spectrometer ELEGANTS-V for studying double beta decays(ββ) of /sup 100/Mo and/or /sup 150/Nd is designed and is now under construction. It consists of drift chambers for identification of tracks and vertex of two β-rays, thin NaI(T1) or plastic scintillators for β-rays energy and NaI(T1) counters for γ- and cosmic-rays. Specifications of the spectrometer; energy resolution, detection efficiency, possible background counting rate and available ββ sources, have been evaluated. The spectrometer has extremely high sensitivities of the neutrinoless ββ decays (0νββ), two neutrino ββ decays (2νββ) and neutrinoless ββ decays followed one boson (Majoron). It may detect 0νββ decays with half lives up to T/sub 1/2/ = 1.2- 1.7 . 10/sup 23/ year. This limit corresponds to one part of million for the Majoran neutrino mass in units of the electron mass and for the right-handed weak current in units of the left handed one

  11. Study of Anterior Chamber Aqueous Tube Shunt by Fourier-Domain Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Chunhui Jiang

    2012-01-01

    Full Text Available Purpose. This cross-sectional, observational study used Fourier-domain optical coherence tomography (OCT to examine the position, patency, and the interior entrance site of anterior chamber (AC aqueous tube shunts. Methods. The OCT, slitlamp biomicroscopy, and gonioscopy findings of 23 eyes of 18 patients with AC shunts were collected and compared. Results. OCT images demonstrated the shunt position and patency in all 23 eyes, and the details of the AC entrance in 16 eyes. The position of the tube varied, with the majority (14/23 on the surface of the iris. The exact position of the AC entrance relative to Schwalbe’s line (SL could be determined in 9 eyes (posterior to SL in 7 eyes, anterior in 2 eyes. At the AC entrance, growth of fibrous scar tissue was present between the tube and the corneal endothelium in all 16 eyes in which the entrance could be clearly visualized. It’s a new finding that could not be visualized by slitlamp examination or lower resolution OCT. Conclusion. Compared to slitlamp examination, Fourier-domain OCT of AC tube shunts provided more detailed anatomic information regarding the insertion level relative to SL, scar tissue between the tube and the corneal endothelium, and patency of the tube opening.

  12. VUV photoemission studies of candidate Large Hadron Collider vacuum chamber materials

    CERN Document Server

    Cimino, R; Baglin, V

    1999-01-01

    In the context of future accelerators and, in particular, the beam vacuum of the Large Hadron Collider (LHC), a 27 km circumference proton collider to be built at CERN, VUV synchrotron radiation (SR) has been used to study both qualitatively and quantitatively candidate vacuum chamber materials. Emphasis is given to show that angle and energy resolved photoemission is an extremely powerful tool to address important issues relevant to the LHC, such as the emission of electrons that contributes to the creation of an electron cloud which may cause serious beam instabilities and unmanageable heat loads on the cryogenic system. Here we present not only the measured photoelectron yields from the proposed materials, prepared on an industrial scale, but also the energy and in some cases the angular dependence of the emitted electrons when excited with either a white light (WL) spectrum, simulating that in the arcs of the LHC, or monochromatic light in the photon energy range of interest. The effects on the materials ...

  13. Study of proton-proton and deuteron-proton interactions by a bubble chamber

    International Nuclear Information System (INIS)

    Shimizu, Fumiya; Katayama, Nobuhiko; Sai, Fuminori

    1981-01-01

    A preliminary report on the analysis of bubble chamber data at the energy of 1.35 and 1.55 GeV/c is described. The purpose of this study is to investigate the behavior of π production cross section in p-p interaction. The total elastic cross sections are 25.0 mb at 1.35 GeV/c and 25.5 mb at 1.55 GeV/c. The cross-sections of π-production such as pp-pnπ + and pp-ppπ 0 were directly obtained. The values were 11.9 mb for pnπ + and 3.5 mb for ppπ 0 at 1.35 GeV/c, and 17.3 mb for pnπ + and 4.7 mb for ppπ 0 at 1.55 GeV/c. The values of ppπ 0 did not agree with previously reported data at high energy. In the production of (delta) 2+ in the pp-pnπ + reaction, Monte Carlo calculation explains well this mass distribution. A preliminary experiment of dp reaction was done at the deuteron energy of 2 GeV/c. The tagging of spectator will be done. (Kato, T.)

  14. Study of reconstruction methods for a time projection chamber with GEM gas amplification system

    Energy Technology Data Exchange (ETDEWEB)

    Diener, R.

    2006-12-15

    A new e{sup +}e{sup -} linear collider with an energy range up to 1TeV is planned in an international collaboration: the International Linear Collider (ILC). This collider will be able to do precision measurements of the Higgs particle and of physics beyond the Standard Model. In the Large Detector Concept (LDC) - which is one proposal for a detector at the ILC - a Time Projection Chamber (TPC) is foreseen as the main tracking device. To meet the requirements on the resolution and to be able to work in the environment at the ILC, the application of new gas amplification technologies in the TPC is necessary. One option is an amplification system based on Gas Electron Multipliers (GEMs). Due to the - in comparison with older technologies - small spatial width of the signals, this technology poses new requirements on the readout structures and the reconstruction methods. In this work, the performance and the systematics of different reconstruction methods have been studied, based on data measured with a TPC prototype in high magnetic fields of up to 4T and data from a Monte Carlo simulation. The latest results of the achievable point resolution are presented and their limitations have been investigated. (orig.)

  15. [Contribution of confocal microscopy and anterior chamber OCT to the study of corneal endothelial pathologies].

    Science.gov (United States)

    Fayol, N; Labbé, A; Dupont-Monod, S; Dupas, B; Baudouin, C

    2007-04-01

    To describe the appearance of various endothelial diseases with in vivo confocal microscopy and anterior chamber optical coherence tomography (AC OCT). In this study, ten patients with five different corneal endothelial pathologies were evaluated. Three patients had cornea guttata, three had corneal endothelial precipitates, two had irido-corneo-endothelial (ICE) syndrome, one had endothelial folds, and one had breaks in the Descemet membrane. All patients had bilateral ophthalmologic examinations, in vivo confocal microscopy, and AC OCT analysis. In cases of cornea guttata, AC OCT showed a finely embossed line corresponding to the empty intercellular cavities found with in vivo confocal microscopy. Corneal endothelium precipitates had the aspect of round formations suspended with the endothelium. Iris atrophy and irido-corneal synechiae resulting from ICE syndrome were precisely visualized with the AC OCT. High-resolution images of the anterior segment could be obtained using the AC OCT. Associated with in vivo confocal microscopy, these two new imaging techniques provide a precise evaluation of endothelial pathologies.

  16. Total OH reactivity study from VOC photochemical oxidation in the SAPHIR chamber

    Science.gov (United States)

    Yu, Z.; Tillmann, R.; Hohaus, T.; Fuchs, H.; Novelli, A.; Wegener, R.; Kaminski, M.; Schmitt, S. H.; Wahner, A.; Kiendler-Scharr, A.

    2015-12-01

    It is well known that hydroxyl radicals (OH) act as a dominant reactive species in the degradation of VOCs in the atmosphere. In recent field studies, directly measured total OH reactivity often showed poor agreement with OH reactivity calculated from VOC measurements (e.g. Nölscher et al., 2013; Lu et al., 2012a). This "missing OH reactivity" is attributed to unaccounted biogenic VOC emissions and/or oxidation products. The comparison of total OH reactivity being directly measured and calculated from single component measurements of VOCs and their oxidation products gives us a further understanding on the source of unmeasured reactive species in the atmosphere. This allows also the determination of the magnitude of the contribution of primary VOC emissions and their oxidation products to the missing OH reactivity. A series of experiments was carried out in the atmosphere simulation chamber SAPHIR in Jülich, Germany, to explore in detail the photochemical degradation of VOCs (isoprene, ß-pinene, limonene, and D6-benzene) by OH. The total OH reactivity was determined from the measurement of VOCs and their oxidation products by a Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-TOF-MS) with a GC/MS/FID system, and directly measured by a laser-induced fluorescence (LIF) at the same time. The comparison between these two total OH reactivity measurements showed an increase of missing OH reactivity in the presence of oxidation products of VOCs, indicating a strong contribution to missing OH reactivity from uncharacterized oxidation products.

  17. Study of reconstruction methods for a time projection chamber with GEM gas amplification system

    International Nuclear Information System (INIS)

    Diener, R.

    2006-12-01

    A new e + e - linear collider with an energy range up to 1TeV is planned in an international collaboration: the International Linear Collider (ILC). This collider will be able to do precision measurements of the Higgs particle and of physics beyond the Standard Model. In the Large Detector Concept (LDC) - which is one proposal for a detector at the ILC - a Time Projection Chamber (TPC) is foreseen as the main tracking device. To meet the requirements on the resolution and to be able to work in the environment at the ILC, the application of new gas amplification technologies in the TPC is necessary. One option is an amplification system based on Gas Electron Multipliers (GEMs). Due to the - in comparison with older technologies - small spatial width of the signals, this technology poses new requirements on the readout structures and the reconstruction methods. In this work, the performance and the systematics of different reconstruction methods have been studied, based on data measured with a TPC prototype in high magnetic fields of up to 4T and data from a Monte Carlo simulation. The latest results of the achievable point resolution are presented and their limitations have been investigated. (orig.)

  18. Large area gridded ionisation chamber and electrostatic precipitator. Application to low-level alphaspectrometry of environmental air samples

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1978-01-01

    A high-resolution, parallel plate Frisch grid ionisation chamber with an efficient area of 300 cm 2 and a large area electrostatic precipitator were developed and applied to direct alpha-particle spectrometry of air dust. The aerosols were deposited on circular tin-plate dishes of 300 cm 2 by the electrostatic precipitator, which was constructed for continuous operation at an air flow rate of 2 m 3 /h. Collection efficiency is found to be 0.78 for the natural Rn- and Tn-daughter products. Using an argon-methane mixture (P-10 gas) at atmospheric pressure, the resolution of the detector system is 22 keV fwhm at 5.15 MeV. The integral background is typically 15.7 counts/h between 4 and 6 MeV. After sampling for one week and decay of short-lived natural activity, the sensitivity of the procedure for long-lived alpha-emitters is about 0.1 fCi/m 3 based on 3s of background as detection limit and 1000 min counting time. (Auth.)

  19. Performance studies under high irradiation of resistive bulk-micromegas chambers at the CERN Gamma Irradiation Facility

    CERN Document Server

    Sidiropoulou, Ourania; Bortfeldt, J; Farina, E; Iengo, P; Longo, L; Sidiropoulou, O; Wotschack, J

    2017-01-01

    Radiation studies on several resistive bulk-Micromegas chambers produced at CERN will be viewed in this document. Two resistive bulk-Micromegas chambers have been installed at the CERN Gamma Irradiation Facility (GIF++) exposed to an intense gamma irradiation with the aim of evaluating the detector behaviour under high irradiation and carrying out a long-term age- ing study. The chambers under study have an active area of 10 x 10 cm 2 , a strip pitch of 400 m m , an ampli- fication gap of 128 m m , and a drift gap of 5 mm. The results on the detector performance as a function of the photon flux up to 44 MHz/cm 2 will be shown as well as the ageing properties as function of the integrated charge and the current intensity and its stability with time. In addition, the results of the efficiency measurements before, during, and after the irradiation will also be presented as a function of the amplification voltage at which the chambers are operated.

  20. A new plant chamber facility, PLUS, coupled to the atmosphere simulation chamber SAPHIR

    Science.gov (United States)

    Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.

    2016-03-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been built and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow-through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees is mixed with synthetic air and transferred to the SAPHIR chamber, where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOCs) can be studied in detail. In PLUS all important environmental parameters (e.g., temperature, photosynthetically active radiation (PAR), soil relative humidity (RH)) are well controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leaves of the plants is constructed such that gases are exposed to only fluorinated ethylene propylene (FEP) Teflon film and other Teflon surfaces to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 light-emitting diode (LED) panels, which have an emission strength up to 800 µmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOCs) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light- and temperature- dependent BVOC emissions are studied using six Quercus ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental setup and the utility of the newly added plant chamber.

  1. Evaluation of transport ventilators at mild simulated altitude: a bench study in a hypobaric chamber.

    Science.gov (United States)

    Boussen, Salah; Coulange, Mathieu; Fournier, Marc; Gainnier, Marc; Michelet, Pierre; Micoli, Christophe; Negrel, Lionel

    2014-08-01

    Previous studies on ventilators used for air transport showed significant effects of altitude, in particular with regard to accuracy of the tidal volume (VT) and breathing frequency. The aim of the study was to evaluate transport ventilators under hypobaric conditions. We conducted a bench study of 6 transport ventilators in a Comex hypobaric chamber to simulate mild altitude (1,500 m [4,920 feet] and 2,500 m [8,200 feet]). The ventilators were connected to a test lung to evaluate their accuracy: (1) to deliver a set VT under normal resistance and compliance conditions at F(IO2) = 0.6 and 1, (2) to establish a set PEEP (0, 5, 10, and 15 cm H2O), and (3) to establish a set inspiratory pressure in pressure controlled mode, (4) at a F(IO2) setting, and (5) and at a frequency setting. Four ventilators kept an average relative error in VT of ventilator was affected by the altitude only at F(IO2) = 1. The Osiris 3 ventilator had > 40% error even at 1,500 m. We found no change in frequency as a function of altitude for any ventilators studied. No clinically important differences were found between all altitudes with the PEEP or inspiratory pressure setting. Although F(IO2) was affected by altitude, the average error did not exceed 11%, and it is unclear whether this fact is an experimental artifact. We have shown that most of the new transport ventilators tested require no setting adjustment at moderate altitude and are as safe at altitude as at sea level under normal respiratory conditions. Older technologies still deliver more volume with altitude in volumetric mode.

  2. A study of the response of ionization chambers to mammography beams

    International Nuclear Information System (INIS)

    Kessler, G.; Burns, D.T.; Buermann, L.; Prez, L.A. de

    2007-03-01

    Some simulated mammography radiation beams have been established at the BIPM using a low-energy x-ray tube with a tungsten anode and molybdenum as a filter. The response of two ionization chambers of different types to these beams is compared with that obtained in mammography beams at the PTB and the NMi which were produced with x-ray tubes with molybdenum anodes and molybdenum filters. The relative differences between the chamber responses to these two different types of beams were less than 7 x 10 -3 which implies the uncertainty for the transfer of a calibration from one type of beam to the other. (authors)

  3. Development of the Experiment Control System and Performance Study of the Muon Chambers for the LHCb Experiment

    CERN Document Server

    Antunes Nobrega, R; Penso, G; Pinci, D

    2010-01-01

    The work of this thesis practically opened three fronts of the LHCb muon system : the development of the control and monitoring system of the readout electronics; the study of noise and threshold of the detector; and the study of the performance of the muon chambers. The LHCb muon readout apparatus is made 1368 Multi-Wire Proportional Chambers (MWPC) and 24 Gas Electron Multiplier (GEM) chambers connected to approximately 7500 16-channel front-end boards, resulting in 120000 output channels. The large-scale of this system naturally led to a complex control and monitoring system made of about 600 microcontrollers which are directly connected to the front-end electronics and handled by six computers. The development of this control system was accomplished within this thesis; the microcontroller’s firmware and the high level software, operating on the six local computers, were implemented. Besides configuring and monitoring the on-chamber readout electronics, a set of calibration and debugging oriented procedu...

  4. Portable mini-chamber for temperature dependent studies using small angle and wide angle x-ray scattering

    Science.gov (United States)

    Dev, Arun Singh; Kumar, Dileep; Potdar, Satish; Pandit, Pallavi; Roth, Stephan V.; Gupta, Ajay

    2018-04-01

    The present work describes the design and performance of a vacuum compatible portable mini chamber for temperature dependent GISAXS and GIWAXS studies of thin films and multilayer structures. The water cooled body of the chamber allows sample annealing up to 900 K using ultra high vacuum compatible (UHV) pyrolytic boron nitride heater, thus making it possible to study the temperature dependent evolution of structure and morphology of two-dimensional nanostructured materials. Due to its light weight and small size, the chamber is portable and can be accommodated at synchrotron facilities worldwide. A systematic illustration of the versatility of the chamber has been demonstrated at beamline P03, PETRA-III, DESY, Hamburg, Germany. Temperature dependent grazing incidence small angle x-ray scattering (GISAXS) and grazing incidence wide angle x-ray scattering (GIWAXS) measurements were performed on oblique angle deposited Co/Ag multilayer structure, which jointly revealed that the surface diffusion in Co columns in Co/Ag multilayer enhances by increasing temperature from RT to ˜573 K. This results in a morphology change from columnar tilted structure to densely packed morphological isotropic multilayer.

  5. Study of the performance of ATLAS muon drift-tube chambers in magntic fields and at high irradiation rates

    Energy Technology Data Exchange (ETDEWEB)

    Valderanis, Chrysostomos

    2012-07-26

    The performance of ATLAS muon drift-tube (MDT) chambers has been studied in detail using high-energy muon beams. The measurements of the drift tube properties in magnetic fields showed that inelastic collisions of the drifting electrons with the CO{sub 2} molecules in the Ar:CO{sub 2} (93:7) gas mixture of the MDT chambers have to be taken into account in the simulation of the drift properties. Such inelastic collisions are now correctly treated by the Garfield simulation programme from version 9 providing an accurate description of the behaviour of the ATLAS muon drift tubes, in particular in the magnetic field. Measurements at the Gamma Irradiation Facility at CERN were performed to study the performance of the MDT chambers in the presence of high {gamma} ray background fluences. The chambers have a spatial resolution better than 40 {mu}m at the nominal background rates expected at the Large Hadron Collider design luminosity of 10{sup 34} cm{sup -2}s{sup -1} and a resolution better than 50 {mu}m for up to five times higher background rates. Efficient muon detection up to background counting rates of 500 kHz per tube corresponding to 35% occupancy was demonstrated.

  6. Ethiopian Journal of Environmental Studies and Management ...

    African Journals Online (AJOL)

    Author Guidelines; » Copyright Notice. Author Guidelines. Guide to Authors: The Ethiopian Journal of Environmental Studies and Management (EJESM) are based in Department of Geography and Environmental Studies, Bahir Dar University, ...

  7. Archives: Ethiopian Journal of Environmental Studies and ...

    African Journals Online (AJOL)

    Items 1 - 50 of 54 ... Archives: Ethiopian Journal of Environmental Studies and Management. Journal Home > Archives: Ethiopian Journal of Environmental Studies and Management. Log in or Register to get access to full text downloads.

  8. Ethiopian Journal of Environmental Studies and Management ...

    African Journals Online (AJOL)

    Ethiopian Journal of Environmental Studies and Management: About this journal. Journal Home > Ethiopian Journal of Environmental Studies and Management: About this journal. Log in or Register to get access to full text downloads.

  9. Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study.

    Science.gov (United States)

    Parekh, Parag; Green, W Richard; Stark, Walter J; Akpek, Esen Karamursel

    2007-02-01

    To report the occurrence of subluxation of suture-fixated posterior chamber (PC) intraocular lenses (IOL) and elucidate the mechanisms involved. Prospective clinicopathologic study. A single 10-0 Prolene suture explanted from a patient who experienced subluxation of his PC-IOL, 11.5 years after placement. Furthermore, multiple 10-0 Prolene sutures and PC-IOLs used for iris fixation were studied as controls. Scanning electron microscopy (SEM) was used to analyze the surface of the explanted suture. In addition, randomly selected 10-0 Prolene sutures cut with Vannas scissors and cut with the positioning holes of a randomly selected PC-IOL identical to that implanted in the patient's eye were examined as controls. Finally, the positioning holes of several randomly selected, iris-fixated PC-IOLs were studied using SEM with particular attention to surface quality and edge finish. Presence of any signs of suture degradation, the character of the cut edge of the suture, as well as the characteristics of the positioning holes of the PC-IOLs. Scanning electron microscopy of the explanted suture revealed sharply cut edges, without significant degradation of the suture, and no intact loop. Scanning electron microscopy of the control suture cut with a PC-IOL demonstrated a similarly cut edge. The positioning holes of the examined PC-IOLs had a sharp edge, and some also had an imperfect finish. We conclude that the surface properties of the positioning holes lead to cutting of the suture, and subsequent subluxation of the PC-IOL.

  10. 30 CFR 256.82 - Environmental studies.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Environmental studies. 256.82 Section 256.82... OIL AND GAS IN THE OUTER CONTINENTAL SHELF Studies § 256.82 Environmental studies. (a) The Director... practicable, be designed to predict environmental impacts of pollutants introduced into the environments and...

  11. Chamber personnel's use of Nitrox 50 during hyperbaric oxygen treatment: a quality study--research report.

    Science.gov (United States)

    Hansen, Marco B; Jansen, Tejs; Sifakis, Michael B; Hyldegaard, Ole; Jansen, Erik C

    2013-01-01

    We aimed to evaluate the feasibility and safety of using Nitrox 50 as breathing gas during attendance in a multiplace hyperbaric chamber. Paper logs between Jan.-Dec. 2011 were reviewed to analyze nitrogen gas-loading, actual bottom time, total bottom time and surface interval time. With the use of the Norwegian Diving Tables nitrogen gas-loading was converted to Repetitive Group Letters. Symptoms of decompression sickness and health problems related to hyperbaric exposures were registered at weekly staff meetings. The chamber personnel breathed chamber air or Nitrox 50. 1,207 hyperbaric exposures were distributed to five chamber attendants and technicians, 14 doctors, and six nurses. Nitrox 50 was inhaled on 978 occasions (81.0%). Median nitrogen gas-loading after first pressurization complied with Repetitive Group Letter A (range A-E), second to C (range A-F), third to D (range A-F), fourth to E (range C-H), fifth to F (range C-H), and sixth to E (range B-G). No symptoms of decompression sickness were reported (95% CI 0.00-0.33%). Breathing Nitrox 50 during repetitive hyperbaric sessions seems to be feasible and safe while meeting high demands in number of treatment sessions and patient flow and with fewer people employed in the hyperbaric unit.

  12. Calculational-theoretical studies of the system of local automated regulators and lateral ionization chambers

    International Nuclear Information System (INIS)

    Aleksakov, A.N.; Emel'yanov, I.Ya.; Nikolaev, E.V.; Panin, V.M.; Podlazov, L.N.; Rogova, V.D.

    1987-01-01

    Methods of engineering synthesis of the systems for nuclear reactor local automated power regulation and radial-azimuthal energy distribution stabilization operating according to lateral ionization chamber signals are described. Results of calculational-theoretical investigations into the system efficiency and peculiarities of its reaction to some perturbations typical of the RBMK type reactors are considered

  13. Performance study of the primary standard ionization chamber for deployment of the diagnostic radiology qualities

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Quaresma, Daniel da Silva; Peixoto, Jose Guilherme Pereira

    2013-01-01

    Activities radiotherapy, diagnostic radiology and radiation protection, require knowledge of physical and dosimetric parameters, to be applied safely. Aiming to meet demand in Brazil, the National Laboratory of Metrology of Ionising Radiation - LNMRI - is deploying the primary standard for the calibration of secondary standard chambers, used in quality control in hospitals, clinics and industries. (author)

  14. A low-pressure cloud chamber to study the spatial distribution of ionizations

    International Nuclear Information System (INIS)

    Hodges, D.C.; Marshall, M.

    1977-01-01

    To further the understanding of the biological effects of radiation a knowledge of the spatial distribution of ionizations in small volumes is required. A cloud chamber capable of resolving the droplets formed on individual ions in the tracks of low-energy electrons has been constructed. It is made to high-vacuum specifications and contains a mixture of permanent gases and vapours, unsaturated before expansion, at a total pressure of 10 kPa. Condensation efficiencies close to 100% are obtained without significant background from condensation on uncharged particles and molecular aggregates. This paper describes the chamber, associated equipment and method of operation and discusses the performance of the system. Photographs of the droplets produced from the interaction of low-energy X-rays in the chamber gas for various modes of operation are presented. The mean energy loss per ion pair for electrons produced by the interaction of Al X-rays in the chamber gas (8130 Pa H 2 , 700 Pa C 2 H 5 OH, 690 Pa H 2 O, 400 Pa He, 70 Pa air) has been measured as 29.8 +- 0.7 eV per ion pair compared with a calculated value of 29.6 +- 0.4 eV per ion pair. (author)

  15. Long term performance studies of large oil-free bakelite resistive plate chamber

    International Nuclear Information System (INIS)

    Ganai, R.; Roy, A.; Ahammed, Z.; Choudhury, S.; Chattopadhyay, S.; Shiroya, M.K.; Agarwal, K.

    2016-01-01

    Several high energy physics and neutrino physics experiments worldwide require large-size RPCs to cover wide acceptances. The muon tracking systems in the Iron calorimeter (ICAL) experiment in the India based Neutrino Observatory (INO), India and the near detector in Deep Underground Neutrino Experiment (DUNE) at Fermilab are two such examples. A single gap bakelite RPC of dimension 240 cm × 120 cm, with gas gap of 0.2 cm, has been built and tested at Variable Energy Cyclotron Centre, Kolkata, using indigenous materials procured from the local market. No additional lubricant, like oil has been used on the electrode surfaces for smoothening. The chamber is in operation for > 365 days. We have tested the chamber for its long term operation. The leakage current, bulk resistivity, efficiency, noise rate and time resolution of the chamber have been found to be quite stable during the testing peroid. It has shown an efficiency > 95% with an average time resolution of ∼ 0.83 ns at the point of measurement at ∼ 8700 V throughout the testing period. Details of the long term performance of the chamber have been discussed.

  16. Long term performance studies of large oil-free bakelite resistive plate chamber

    Science.gov (United States)

    Ganai, R.; Roy, A.; Shiroya, M. K.; Agarwal, K.; Ahammed, Z.; Choudhury, S.; Chattopadhyay, S.

    2016-09-01

    Several high energy physics and neutrino physics experiments worldwide require large-size RPCs to cover wide acceptances. The muon tracking systems in the Iron calorimeter (ICAL) experiment in the India based Neutrino Observatory (INO), India and the near detector in Deep Underground Neutrino Experiment (DUNE) at Fermilab are two such examples. A single gap bakelite RPC of dimension 240 cm × 120 cm, with gas gap of 0.2 cm, has been built and tested at Variable Energy Cyclotron Centre, Kolkata, using indigenous materials procured from the local market. No additional lubricant, like oil has been used on the electrode surfaces for smoothening. The chamber is in operation for > 365 days. We have tested the chamber for its long term operation. The leakage current, bulk resistivity, efficiency, noise rate and time resolution of the chamber have been found to be quite stable during the testing peroid. It has shown an efficiency > 95% with an average time resolution of ~ 0.83 ns at the point of measurement at ~ 8700 V throughout the testing period. Details of the long term performance of the chamber have been discussed.

  17. [Studies of ozone formation potentials for benzene and ethylbenzene using a smog chamber and model simulation].

    Science.gov (United States)

    Jia, Long; Xu, Yong-Fu

    2014-02-01

    Ozone formation potentials from irradiations of benzene-NO(x) and ethylbenzene-NO(x) systems under the conditions of different VOC/NO(x) ratios and RH were investigated using a characterized chamber and model simulation. The repeatability of the smog chamber experiment shows that for two sets of ethylbenzene-NO(x) irradiations with similar initial concentrations and reaction conditions, such as temperature, relative humidity and relative light intensity, the largest difference in O3 between two experiments is only 4% during the whole experimental run. On the basis of smog chamber experiments, ozone formation of photo-oxidation of benzene and ethylbenzene was simulated in terms of the master chemical mechanism (MCM). The peak ozone values for benzene and ethylbenzene simulated by MCM are higher than the chamber data, and the difference between the MCM-simulated results and chamber data increases with increasing RH. Under the conditions of sunlight irradiations, with benzene and ethylbenzene concentrations being in the range of (10-50) x 10(-9) and NO(x) concentrations in the range of (10-100) x 10(-9), the 6 h ozone contributions of benzene and ethylbenzene were obtained to be (3.1-33) x 10(-9) and (2.6-122) x 10(-9), whereas the peak O3 contributions of benzene and ethylbenzene were (3.5-54) x 10(-9) and (3.8-164) x 10(-9), respectively. The MCM-simulated maximum incremental reactivity (MIR) values for benzene and ethylbenzene were 0.25/C and 0.97/C (per carbon), respectively. The maximum ozone reactivity (MOR) values for these two species were obtained to be 0.73/C and 1.03/C, respectively. The MOR value of benzene from MCM is much higher than that obtained by carter from SAPRC, indicating that SAPRC may underestimate the ozone formation potential of benzene.

  18. METs in adults while playing active video games: a metabolic chamber study.

    Science.gov (United States)

    Miyachi, Motohiko; Yamamoto, Kenta; Ohkawara, Kazunori; Tanaka, Shigeho

    2010-06-01

    Active video game systems controlled through arm gestures and motions (Nintendo Wii Sports) and video games controlled through force plate (Wii Fit Plus) are becoming increasingly popular. This study was performed to determine the energy expenditure (EE) during Wii Fit Plus and Wii Sports game activities. Twelve adult men and women performed all the activities of Wii Sports (five activities: golf, bowling, tennis, baseball, and boxing) and Wii Fit Plus (63 activities classified as yoga, resistance, balance, and aerobic exercises). Each activity was continued for at least 8 min to obtain a steady-state EE. Because EE was assessed in an open-circuit indirect metabolic chamber consisting of an airtight room (20,000 or 15,000 L), subjects were freed of apparatus to collect expired gas while playing the games. MET value was calculated from resting EE and steady-state EE during activity. The mean MET values of all 68 activities were distributed over a wide range from 1.3 METs (Lotus Focus) to 5.6 METs (single-arm stand). The mean MET values in yoga, balance, resistance, and aerobic exercise of Wii Fit Plus and Wii Sports were 2.1, 2.0, 3.2, 3.4, and 3.0 METs, respectively. Forty-six activities (67%) were classified as light intensity (6.0 METs). Time spent playing one-third of the activities supplied by motion- and gesture-controlled video games can count toward the daily amount of exercise required according to the guidelines provided by the American College of Sports Medicine and the American Heart Association, which focus on 30 min of moderate-intensity daily physical activity 5 d x wk(-1).

  19. Nasal hyperresponders and atopic subjects report different symptom intensity to air quality: a climate chamber study.

    Science.gov (United States)

    Bodin, L; Andersson, K; Bønløkke, J H; Mølhave, L; Kjaergaard, S K; Stridh, G; Juto, J-E; Sigsgaard, T

    2009-06-01

    Short-term exposure to dust and dust added with beta-(1,3)-d-glucan or aldehydes may cause sensory reactions. In random order, we exposed 36 volunteers in a climate chamber to clean air, office dust, dust with glucan, and dust with aldehydes. Three groups of subjects were exposed, eleven were non-atopic with nasal histamine hyperreactivity, 13 were non-atopic, and 12 were atopic. Subjective ratings of symptoms and general health were registered four times during four 6-h exposure sessions. Six symptom intensity indices were constructed. The nasal hyperreactive group had a high and time-dependent increase of mucous membrane irritations, whereas the atopic group had a low and stable rate of irritations with exposure time, close to the reference group (P = 0.02 for differences between the groups with respect to time under exposure for Weak Inflammatory Responses and P = 0.05 for Irritative Body Perception, significance mainly because of the nasal hyperreactive group). Exposure to dust, with or without glucan or aldehydes, showed increased discomfort measured by the index for Constant Indoor Climate, and dust with glucan had a similar effect for the index for Lower Respiratory Effects. For Psychological and Neurological Effects these were dependent on group affiliation, thus preventing a uniform statement of exposure effects for all three investigated groups. Opportunities for identifying persons with high or low sensitivity to low-level exposures are important in preventive medicine and will reduce intra-group variability and thus increase the power of experimental and epidemiological studies searching for correlations between exposures and health effects. The contrast between nasal hyperreactive on one side and atopic and reference subjects on the other side is particularly important. The atopic group indicated a non-homogenous reaction depending on their hyperreactive status, a finding that could be important but needs further confirmation.

  20. Criteria of choice in the planning of a solar radiation lamp arrangement, in climatic chambers for plant physiology studies

    International Nuclear Information System (INIS)

    Materassi, A.; Fasano, G.; Vincenzi, M. De

    2006-01-01

    This technical note is an integration of the previous study: Climatic chambers for plant physiology: a new project concept. This note gives details regarding the planning of the lamp arrangement and demonstrates how mixing, in appropriate quantities, the radiative range of various types of lamps can give apparently contrasting results: to maximize radiation in maximum absorption range of chlorophylls and carotenoids; to minimize heat emission in the climatic chamber. With nine daylight fluorescent tubes, four sunlight metallic halide spotlights and nine red-blue fluorescent tubes, for a total of 562 W mE-2 (electric), mounted on the ceiling of a 2 m high chamber with a 4 square m surface area, on the chamber floor about 130 W mE-2 total solar radiation equivalent was obtained. This means a power emitted, in the bands of chlorophylls and carotenoids absorption, from a total solar radiation (black body of 5,500 K) of about 130 W mE-2. This radiation is sufficient to grow a large number of plant species. In the lamp arrangement there are seven other light fixtures, for fluorescent tubes, defined as auxiliary because tubes can be inserted which either integrate active radiation on the photoreceptors or produce particular spectral ranges. In the above cited work, fluorescent tubes producing in the ultraviolet B range were mounted in these auxiliary fixtures. Less thermal energy emitted in the climatic chamber means that it is possible to use a less powerful conditioning system and, thus, have lower costs of set-up and management. The efficiency of the lighting system is demonstrated by the fact that during 15 days of experimentation on 18-month-old, potted poplar plants (Populus alba), symptoms of insufficient light were not detected [it

  1. Natural radioactivity in environmental studies

    International Nuclear Information System (INIS)

    Heijnis, H.; Jenkinson, A.; Chisari, R.

    1998-01-01

    Full text: The use natural radioactivity in environmental studies has proven a very powerful tool to determine the dynamics of both natural and antrophogenic processes in our environment. The use of 14 C in archeology and past climate studies has led to many scientific discoveries (i.e. shroud of Turin and Utze 'the ice-man' from Austria). The use of the 238 U-decay series is of at least equal value to studies in archeology and past climates. Some of the Isotopes studied supplement 14 C (which is limited to 40,000 years) up to 350,000 years and others can be utilized to date very young sediments, which can't be dated by 14 C. The so-called 210 Pb dating method has been used over the past 3 decades to date recent sediment. The method uses the disequilibrium in the 238 U decay chain, caused by the escape of the intermediate daughter 222 Rn (a noble gas) from the earth's crust. In the atmosphere the 222 Rn decays via short-lived daughter isotopes to 210 Pb. This 210 Pb with a very convenient half-life of 22,3 years decays to stable 206 Pb. By measuring the surface activity of a sediment core and subsequent samples at regular intervals one can establish a chronology for the sediment core. By studying the trace metals in these cores, one could deduce a contamination history for the region. Examples of studies supported by AINSE and ANSTO will be given

  2. Comparative study of environmental impact assessment methods ...

    African Journals Online (AJOL)

    This study aims to introduce and systematically investigate the environmental issues during important decision-making stages. Meanwhile, impacts of development on the environmental components will be also analyzed. This research studies various methods of predicting the environmental changes and determining the ...

  3. Sustainability: Environmental Studies and Public Health

    Directory of Open Access Journals (Sweden)

    Miklas Scholz

    2009-10-01

    Full Text Available This special issue ‘Sustainability: Environmental Studies and Public Health’ is part of the internationally leading 'International Journal of Environmental Research and Public Health’. I was invited to be the guest editor, and to oversee the refereeing process and subsequent selection of timely, relevant and high quality papers highlighting particularly novel aspects concerned with sustainability issues in environmental studies. [...

  4. Sustainability: Environmental Studies and Public Health

    OpenAIRE

    Scholz, Miklas

    2009-01-01

    This special issue ‘Sustainability: Environmental Studies and Public Health’ is part of the internationally leading 'International Journal of Environmental Research and Public Health’. I was invited to be the guest editor, and to oversee the refereeing process and subsequent selection of timely, relevant and high quality papers highlighting particularly novel aspects concerned with sustainability issues in environmental studies. [...

  5. A study of various types of electronics for drift chambers: development of a test bench and results for 1500 channels

    International Nuclear Information System (INIS)

    Kostarakis, Panayotis.

    1976-01-01

    An electronic chain to be connected with drift chambers is studied for use in High Energy Physics. Studies have been made to define the best components to be put into the elements (amplifiers, cables, TDC...). Measurements have been done to determine the characteristics of the chosen elements. A test apparatus has been built to control each channel (about 1550). Finally all chain elements have been tested [fr

  6. Studies of field distortions in a time projection chamber for the International Linear Collider

    International Nuclear Information System (INIS)

    Zenker, Klaus

    2014-12-01

    The International Linear Collider (ILC) will allow to do precision measurements of Standard Model parameter and to search for new physics. The ILD detector concept, which is developed for the ILC, uses a Time Projection Chamber (TPC) as central tracking device. The momentum resolution goal for the ILD TPC is δ(1/p t ) ≅ 10 -4 (GeV/c) -1 at a magnetic field of B=3.5 T. Field distortions of the magnetic or electric field inside the sensitive volume of the TPC distort the momentum measurements. Therefore, one needs to keep them under control and correct them with high precision. In this thesis the main sources of field distortions in the TPC are identified and their effects are determined. Furthermore, possibilities to reduce the identified field distortions are presented. One known source of distortions of the electric field are ions, produced by the gas amplification in the TPC anode, that drift into the sensitive volume of the TPC. In the first part of this work the creation of these ions in Gas Electron Multiplier (GEM), which are used for the gas amplification, is studied. It will be shown that the resulting field distortions are not acceptable at the ILD TPC. By tuning the parameters of the gas amplification at the anode the field distortion can be reduced, which is shown in measurements and simulations. In addition measurements using a modified GEM show that it is possible to further reduce the field distortions with such a GEM. In the second part of this work field distortions arising at boundaries between individual readout modules are investigated using simulation studies. It will be shown in simulations, which are verified by measurement results, that these field distortions significantly influence the readout module performance. Based on the simulation results the GEM based readout module developed at DESY is optimised and the field distortions are reduced. These performance improvements could also be verified in measurements. Finally, a laser

  7. Studies on the beam system for the calibration of the OPAL jet chamber with laser beams

    International Nuclear Information System (INIS)

    Maringer, G.

    1988-07-01

    UV laser beams are an important tool for the calibration of the OPAL jet chamber. A beam transport system containing about 350 mirrors in total guides the beams from the laser outside the detector into the chamber. Four of the mirrors are moveable under remote control allowing to guide the beams into each of the 24 sectors and to correct the beam path in case of deviations. A program to control these moveable mirrors has been developed. Drift velocity measurements will be performed by means of double beams which are generated by appropriate beamsplitters. Accurate knowledge of the double beam distances is essential to obtain the desired accuracy of better than 0.1% or 10 μm. Using a CCD device with a pixel size of 23x23 μm 2 the beam distance could be measured with errors below the required limit. (orig.)

  8. Automation of the reading of an ionization chamber: study and design of a data transfer system

    International Nuclear Information System (INIS)

    RANDRIAMAHOLISOA, C.O.

    1999-01-01

    Management of information obtained through ionization chamber, type of detector the most employed in centers or institutions using ionizing radiation machines and radioactive sources, is done manually because data are fed into computers from keyboard. This procedure presents hazards of loss and bad transcription of information. A more practical way of getting over this handicap is the setting up of a system that transfers data from ionization chamber into computer. Thereafter, it will be easier for the user to adjust his data processing software to the system underconsideration. This system, even though not directly designed to process data, that being a specific task of each user, is constituted of an electronic aspect which plays the interface part between them. It takes account parameters having relevance to the quality and the quantity of information put out by the detector [fr

  9. Study of charm and bottom particle production using a holographic bubble chamber

    CERN Multimedia

    2002-01-01

    The experimental arrangement consists mainly of a small, rapid cycling, heavy liquid bubble chamber, HOBC, equipped for holography and a muon detector. The high spatial resolution which can be obtained in a small holographic bubble chamber (5-10 $\\mu$m) allows a good efficiency for the detection of shortlived particles like charm and bottom particles. With the one muon trigger the proportion of these particles is greatly enhanced. \\\\\\\\For the first phase of the experiment the emphasis is on the determination of charm cross-sections. The aim is to determine the production cross-sections at 100, 200 and 300 GeV/c for different incident particles, and consequently determine the energy dependence of the charm cross-sections.

  10. Experimental study of improvement on combustion control of fluidized bed combustion chamber; Ryudosho shokyakuro no nenshosei no kaizen ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Izumiya, T.; Baba, K.; Koshida, H.; Uetani, J.; Furuta, M.

    1998-10-29

    Nippon Steel Corporation has carried out an experimental study using the Yawata waste incinerator plant in order to improve combustion control of a fluidized bed combustion chamber. For controlling the forming of dioxin, combustion control is very important in addition to conventional methods. In this paper, we report two studies about improvements on combustion control. In the first study, we verified improvement on combustion control by modifying gas flow at the freeboard. The operational results of the experiments were studied using the numerical model of the combustion chamber. The modification of gas flow at freeboard was confirmed to be effective to obtain a compact design of fluidized bed combustion chamber for municipal waste. In the second, study we improved combustion control for sewage combustion with municipal waste. In burning municipal waste and sewage, it is especially required to take combustion control into careful consideration. In this experiment, we developed a new device for supplying sewage for the appropriate controlling combustion, and verified its effectiveness to combustion control and an effective reduction of dioxin. (author)

  11. Performance Study of the CMS Barrel Resistive Plate Chambers with Cosmic Rays

    CERN Document Server

    Chatrchyan, S; Sirunyan, A M; Adam, W; Arnold, B; Bergauer, H; Bergauer, T; Dragicevic, M; Eichberger, M; Erö, J; Friedl, M; Frühwirth, R; Ghete, V M; Hammer, J; Hänsel, S; Hoch, M; Hörmann, N; Hrubec, J; Jeitler, M; Kasieczka, G; Kastner, K; Krammer, M; Liko, D; Magrans de Abril, I; Mikulec, I; Mittermayr, F; Neuherz, B; Oberegger, M; Padrta, M; Pernicka, M; Rohringer, H; Schmid, S; Schöfbeck, R; Schreiner, T; Stark, R; Steininger, H; Strauss, J; Taurok, A; Teischinger, F; Themel, T; Uhl, D; Wagner, P; Waltenberger, W; Walzel, G; Widl, E; Wulz, C E; Chekhovsky, V; Dvornikov, O; Emeliantchik, I; Litomin, A; Makarenko, V; Marfin, I; Mossolov, V; Shumeiko, N; Solin, A; Stefanovitch, R; Suarez Gonzalez, J; Tikhonov, A; Fedorov, A; Karneyeu, A; Korzhik, M; Panov, V; Zuyeuski, R; Kuchinsky, P; Beaumont, W; Benucci, L; Cardaci, M; De Wolf, E A; Delmeire, E; Druzhkin, D; Hashemi, M; Janssen, X; Maes, T; Mucibello, L; Ochesanu, S; Rougny, R; Selvaggi, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Adler, V; Beauceron, S; Blyweert, S; D'Hondt, J; De Weirdt, S; Devroede, O; Heyninck, J; Kalogeropoulos, A; Maes, J; Maes, M; Mozer, M U; Tavernier, S; Van Doninck, W; Van Mulders, P; Villella, I; Bouhali, O; Chabert, E C; Charaf, O; Clerbaux, B; De Lentdecker, G; Dero, V; Elgammal, S; Gay, A P R; Hammad, G H; Marage, P E; Rugovac, S; Vander Velde, C; Vanlaer, P; Wickens, J; Grunewald, M; Klein, B; Marinov, A; Ryckbosch, D; Thyssen, F; Tytgat, M; Vanelderen, L; Verwilligen, P; Basegmez, S; Bruno, G; Caudron, J; Delaere, C; Demin, P; Favart, D; Giammanco, A; Grégoire, G; Lemaitre, V; Militaru, O; Ovyn, S; Piotrzkowski, K; Quertenmont, L; Schul, N; Beliy, N; Daubie, E; Alves, G A; Pol, M E; Souza, M H G; Carvalho, W; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Mundim, L; Oguri, V; Santoro, A; Silva Do Amaral, S M; Sznajder, A; Fernandez Perez Tomei, T R; Ferreira Dias, M A; Gregores, E M; Novaes, S F; Abadjiev, K; Anguelov, T; Damgov, J; Darmenov, N; Dimitrov, L; Genchev, V; Iaydjiev, P; Piperov, S; Stoykova, S; Sultanov, G; Trayanov, R; Vankov, I; Dimitrov, A; Dyulendarova, M; Kozhuharov, V; Litov, L; Marinova, E; Mateev, M; Pavlov, B; Petkov, P; Toteva, Z; Chen, G M; Chen, H S; Guan, W; Jiang, C H; Liang, D; Liu, B; Meng, X; Tao, J; Wang, J; Wang, Z; Xue, Z; Zhang, Z; Ban, Y; Cai, J; Ge, Y; Guo, S; Hu, Z; Mao, Y; Qian, S J; Teng, H; Zhu, B; Avila, C; Baquero Ruiz, M; Carrillo Montoya, C A; Gomez, A; Gomez Moreno, B; Ocampo Rios, A A; Osorio Oliveros, A F; Reyes Romero, D; Sanabria, J C; Godinovic, N; Lelas, K; Plestina, R; Polic, D; Puljak, I; Antunovic, Z; Dzelalija, M; Brigljevic, V; Duric, S; Kadija, K; Morovic, S; Fereos, R; Galanti, M; Mousa, J; Papadakis, A; Ptochos, F; Razis, P A; Tsiakkouri, D; Zinonos, Z; Hektor, A; Kadastik, M; Kannike, K; Müntel, M; Raidal, M; Rebane, L; Anttila, E; Czellar, S; Härkönen, J; Heikkinen, A; Karimäki, V; Kinnunen, R; Klem, J; Kortelainen, M J; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Nysten, J; Tuominen, E; Tuominiemi, J; Ungaro, D; Wendland, L; Banzuzi, K; Korpela, A; Tuuva, T; Nedelec, P; Sillou, D; Besancon, M; Chipaux, R; Dejardin, M; Denegri, D; Descamps, J; Fabbro, B; Faure, J L; Ferri, F; Ganjour, S; Gentit, F X; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Lemaire, M C; Locci, E; Malcles, J; Marionneau, M; Millischer, L; Rander, J; Rosowsky, A; Rousseau, D; Titov, M; Verrecchia, P; Baffioni, S; Bianchini, L; Bluj, M; Busson, P; Charlot, C; Dobrzynski, L; Granier de Cassagnac, R; Haguenauer, M; Miné, P; Paganini, P; Sirois, Y; Thiebaux, C; Zabi, A; Agram, J L; Besson, A; Bloch, D; Bodin, D; Brom, J M; Conte, E; Drouhin, F; Fontaine, J C; Gelé, D; Goerlach, U; Gross, L; Juillot, P; Le Bihan, A C; Patois, Y; Speck, J; Van Hove, P; Baty, C; Bedjidian, M; Blaha, J; Boudoul, G; Brun, H; Chanon, N; Chierici, R; Contardo, D; Depasse, P; Dupasquier, T; El Mamouni, H; Fassi, F; Fay, J; Gascon, S; Ille, B; Kurca, T; Le Grand, T; Lethuillier, M; Lumb, N; Mirabito, L; Perries, S; Vander Donckt, M; Verdier, P; Djaoshvili, N; Roinishvili, N; Roinishvili, V; Amaglobeli, N; Adolphi, R; Anagnostou, G; Brauer, R; Braunschweig, W; Edelhoff, M; Esser, H; Feld, L; Karpinski, W; Khomich, A; Klein, K; Mohr, N; Ostaptchouk, A; Pandoulas, D; Pierschel, G; Raupach, F; Schael, S; Schultz von Dratzig, A; Schwering, G; Sprenger, D; Thomas, M; Weber, M; Wittmer, B; Wlochal, M; Actis, O; Altenhöfer, G; Bender, W; Biallass, P; Erdmann, M; Fetchenhauer, G; Frangenheim, J; Hebbeker, T; Hilgers, G; Hinzmann, A; Hoepfner, K; Hof, C; Kirsch, M; Klimkovich, T; Kreuzer, P; Lanske, D; Merschmeyer, M; Meyer, A; Philipps, B; Pieta, H; Reithler, H; Schmitz, S A; Sonnenschein, L; Sowa, M; Steggemann, J; Szczesny, H; Teyssier, D; Zeidler, C; Bontenackels, M; Davids, M; Duda, M; Flügge, G; Geenen, H; Giffels, M; Haj Ahmad, W; Hermanns, T; Heydhausen, D; Kalinin, S; Kress, T; Linn, A; Nowack, A; Perchalla, L; Poettgens, M; Pooth, O; Sauerland, P; Stahl, A; Tornier, D; Zoeller, M H; Aldaya Martin, M; Behrens, U; Borras, K; Campbell, A; Castro, E; Dammann, D; Eckerlin, G; Flossdorf, A; Flucke, G; Geiser, A; Hatton, D; Hauk, J; Jung, H; Kasemann, M; Katkov, I; Kleinwort, C; Kluge, H; Knutsson, A; Kuznetsova, E; Lange, W; Lohmann, W; Mankel, R; Marienfeld, M; Meyer, A B; Miglioranzi, S; Mnich, J; Ohlerich, M; Olzem, J; Parenti, A; Rosemann, C; Schmidt, R; Schoerner-Sadenius, T; Volyanskyy, D; Wissing, C; Zeuner, W D; Autermann, C; Bechtel, F; Draeger, J; Eckstein, D; Gebbert, U; Kaschube, K; Kaussen, G; Klanner, R; Mura, B; Naumann-Emme, S; Nowak, F; Pein, U; Sander, C; Schleper, P; Schum, T; Stadie, H; Steinbrück, G; Thomsen, J; Wolf, R; Bauer, J; Blüm, P; Buege, V; Cakir, A; Chwalek, T; De Boer, W; Dierlamm, A; Dirkes, G; Feindt, M; Felzmann, U; Frey, M; Furgeri, A; Gruschke, J; Hackstein, C; Hartmann, F; Heier, S; Heinrich, M; Held, H; Hirschbuehl, D; Hoffmann, K H; Honc, S; Jung, C; Kuhr, T; Liamsuwan, T; Martschei, D; Mueller, S; Müller, Th; Neuland, M B; Niegel, M; Oberst, O; Oehler, A; Ott, J; Peiffer, T; Piparo, D; Quast, G; Rabbertz, K; Ratnikov, F; Ratnikova, N; Renz, M; Saout, C; Sartisohn, G; Scheurer, A; Schieferdecker, P; Schilling, F P; Schott, G; Simonis, H J; Stober, F M; Sturm, P; Troendle, D; Trunov, A; Wagner, W; Wagner-Kuhr, J; Zeise, M; Zhukov, V; Ziebarth, E B; Daskalakis, G; Geralis, T; Karafasoulis, K; Kyriakis, A; Loukas, D; Markou, A; Markou, C; Mavrommatis, C; Petrakou, E; Zachariadou, A; Gouskos, L; Katsas, P; Panagiotou, A; Evangelou, I; Kokkas, P; Manthos, N; Papadopoulos, I; Patras, V; Triantis, F A; Bencze, G; Boldizsar, L; Debreczeni, G; Hajdu, C; Hernath, S; Hidas, P; Horvath, D; Krajczar, K; Laszlo, A; Patay, G; Sikler, F; Toth, N; Vesztergombi, G; Beni, N; Christian, G; Imrek, J; Molnar, J; Novak, D; Palinkas, J; Szekely, G; Szillasi, Z; Tokesi, K; Veszpremi, V; Kapusi, A; Marian, G; Raics, P; Szabo, Z; Trocsanyi, Z L; Ujvari, B; Zilizi, G; Bansal, S; Bawa, H S; Beri, S B; Bhatnagar, V; Jindal, M; Kaur, M; Kaur, R; Kohli, J M; Mehta, M Z; Nishu, N; Saini, L K; Sharma, A; Singh, A; Singh, J B; Singh, S P; Ahuja, S; Arora, S; Bhattacharya, S; Chauhan, S; Choudhary, B C; Gupta, P; Jain, S; Jha, M; Kumar, A; Ranjan, K; Shivpuri, R K; Srivastava, A K; Choudhury, R K; Dutta, D; Kailas, S; Kataria, S K; Mohanty, A K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Guchait, M; Gurtu, A; Maity, M; Majumder, D; Majumder, G; Mazumdar, K; Nayak, A; Saha, A; Sudhakar, K; Banerjee, S; Dugad, S; Mondal, N K; Arfaei, H; Bakhshiansohi, H; Fahim, A; Jafari, A; Mohammadi Najafabadi, M; Moshaii, A; Paktinat Mehdiabadi, S; Rouhani, S; Safarzadeh, B; Zeinali, M; Felcini, M; Abbrescia, M; Barbone, L; Chiumarulo, F; Clemente, A; Colaleo, A; Creanza, D; Cuscela, G; De Filippis, N; De Palma, M; De Robertis, G; Donvito, G; Fedele, F; Fiore, L; Franco, M; Iaselli, G; Lacalamita, N; Loddo, F; Lusito, L; Maggi, G; Maggi, M; Manna, N; Marangelli, B; My, S; Natali, S; Nuzzo, S; Papagni, G; Piccolomo, S; Pierro, G A; Pinto, C; Pompili, A; Pugliese, G; Rajan, R; Ranieri, A; Romano, F; Roselli, G; Selvaggi, G; Shinde, Y; Silvestris, L; Tupputi, S; Zito, G; Abbiendi, G; Bacchi, W; Benvenuti, A C; Boldini, M; Bonacorsi, D; Braibant-Giacomelli, S; Cafaro, V D; Caiazza, S S; Capiluppi, P; Castro, A; Cavallo, F R; Codispoti, G; Cuffiani, M; D'Antone, I; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Giordano, V; Giunta, M; Grandi, C; Guerzoni, M; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Odorici, F; Pellegrini, G; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G; Torromeo, G; Travaglini, R; Albergo, S; Costa, S; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Broccolo, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Frosali, S; Gallo, E; Genta, C; Landi, G; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Tropiano, A; Benussi, L; Bertani, M; Bianco, S; Colafranceschi, S; Colonna, D; Fabbri, F; Giardoni, M; Passamonti, L; Piccolo, D; Pierluigi, D; Ponzio, B; Russo, A; Fabbricatore, P; Musenich, R; Benaglia, A; Calloni, M; Cerati, G B; D'Angelo, P; De Guio, F; Farina, F M; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Martelli, A; Menasce, D; Miccio, V; Moroni, L; Negri, P; Paganoni, M; Pedrini, D; Pullia, A; Ragazzi, S; Redaelli, N; Sala, S; Salerno, R; Tabarelli de Fatis, T; Tancini, V; Taroni, S; Buontempo, S; Cavallo, N; Cimmino, A; De Gruttola, M; Fabozzi, F; Iorio, A O M; Lista, L; Lomidze, D; Noli, P; Paolucci, P; Sciacca, C; Azzi, P; Bacchetta, N; Barcellan, L; Bellan, P; Bellato, M; Benettoni, M; Biasotto, M; Bisello, D; Borsato, E; Branca, A; Carlin, R; Castellani, L; Checchia, P; Conti, E; Dal Corso, F; De Mattia, M; Dorigo, T; Dosselli, U; Fanzago, F; Gasparini, F; Gasparini, U; Giubilato, P; Gonella, F; Gresele, A; Gulmini, M; Kaminskiy, A; Lacaprara, S; Lazzizzera, I; Margoni, M; Maron, G; Mattiazzo, S; Mazzucato, M; Meneghelli, M; Meneguzzo, A T; Michelotto, M; Montecassiano, F; Nespolo, M; Passaseo, M; Pegoraro, M; Perrozzi, L; Pozzobon, N; Ronchese, P; Simonetto, F; Toniolo, N; Torassa, E; Tosi, M; Triossi, A; Vanini, S; Ventura, S; Zotto, P; Zumerle, G; Baesso, P; Berzano, U; Bricola, S; Necchi, M M; Pagano, D; Ratti, S P; Riccardi, C; Torre, P; Vicini, A; Vitulo, P; Viviani, C; Aisa, D; Aisa, S; Babucci, E; Biasini, M; Bilei, G M; Caponeri, B; Checcucci, B; Dinu, N; Fanò, L; Farnesini, L; Lariccia, P; Lucaroni, A; Mantovani, G; Nappi, A; Piluso, A; Postolache, V; Santocchia, A; Servoli, L; Tonoiu, D; Vedaee, A; Volpe, R; Azzurri, P; Bagliesi, G; Bernardini, J; Berretta, L; Boccali, T; Bocci, A; Borrello, L; Bosi, F; Calzolari, F; Castaldi, R; Dell'Orso, R; Fiori, F; Foà, L; Gennai, S; Giassi, A; Kraan, A; Ligabue, F; Lomtadze, T; Mariani, F; Martini, L; Massa, M; Messineo, A; Moggi, A; Palla, F; Palmonari, F; Petragnani, G; Petrucciani, G; Raffaelli, F; Sarkar, S; Segneri, G; Serban, A T; Spagnolo, P; Tenchini, R; Tolaini, S; Tonelli, G; Venturi, A; Verdini, P G; Baccaro, S; Barone, L; Bartoloni, A; Cavallari, F; Dafinei, I; Del Re, D; Di Marco, E; Diemoz, M; Franci, D; Longo, E; Organtini, G; Palma, A; Pandolfi, F; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Alampi, G; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Biino, C; Borgia, M A; Botta, C; Cartiglia, N; Castello, R; Cerminara, G; Costa, M; Dattola, D; Dellacasa, G; Demaria, N; Dughera, G; Dumitrache, F; Graziano, A; Mariotti, C; Marone, M; Maselli, S; Migliore, E; Mila, G; Monaco, V; Musich, M; Nervo, M; Obertino, M M; Oggero, S; Panero, R; Pastrone, N; Pelliccioni, M; Romero, A; Ruspa, M; Sacchi, R; Solano, A; Staiano, A; Trapani, P P; Trocino, D; Vilela Pereira, A; Visca, L; Zampieri, A; Ambroglini, F; Belforte, S; Cossutti, F; Della Ricca, G; Gobbo, B; Penzo, A; Chang, S; Chung, J; Kim, D H; Kim, G N; Kong, D J; Park, H; Son, D C; Bahk, S Y; Song, S; Jung, S Y; Hong, B; Kim, H; Kim, J H; Lee, K S; Moon, D H; Park, S K; Rhee, H B; Sim, K S; Kim, J; Choi, M; Hahn, G; Park, I C; Choi, S; Choi, Y; Goh, J; Jeong, H; Kim, T J; Lee, J; Lee, S; Janulis, M; Martisiute, D; Petrov, P; Sabonis, T; Castilla Valdez, H; Sánchez Hernández, A; Carrillo Moreno, S; Morelos Pineda, A; Allfrey, P; Gray, R N C; Krofcheck, D; Bernardino Rodrigues, N; Butler, P H; Signal, T; Williams, J C; Ahmad, M; Ahmed, I; Ahmed, W; Asghar, M I; Awan, M I M; Hoorani, H R; Hussain, I; Khan, W A; Khurshid, T; Muhammad, S; Qazi, S; Shahzad, H; Cwiok, M; Dabrowski, R; Dominik, W; Doroba, K; Konecki, M; Krolikowski, J; Pozniak, K; Romaniuk, Ryszard; Zabolotny, W; Zych, P; Frueboes, T; Gokieli, R; Goscilo, L; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Wrochna, G; Zalewski, P; Almeida, N; Antunes Pedro, L; Bargassa, P; David, A; Faccioli, P; Ferreira Parracho, P G; Freitas Ferreira, M; Gallinaro, M; Guerra Jordao, M; Martins, P; Mini, G; Musella, P; Pela, J; Raposo, L; Ribeiro, P Q; Sampaio, S; Seixas, J; Silva, J; Silva, P; Soares, D; Sousa, M; Varela, J; Wöhri, H K; Altsybeev, I; Belotelov, I; Bunin, P; Ershov, Y; Filozova, I; Finger, M; Finger, M., Jr.; Golunov, A; Golutvin, I; Gorbounov, N; Kalagin, V; Kamenev, A; Karjavin, V; Konoplyanikov, V; Korenkov, V; Kozlov, G; Kurenkov, A; Lanev, A; Makankin, A; Mitsyn, V V; Moisenz, P; Nikonov, E; Oleynik, D; Palichik, V; Perelygin, V; Petrosyan, A; Semenov, R; Shmatov, S; Smirnov, V; Smolin, D; Tikhonenko, E; Vasil'ev, S; Vishnevskiy, A; Volodko, A; Zarubin, A; Zhiltsov, V; Bondar, N; Chtchipounov, L; Denisov, A; Gavrikov, Y; Gavrilov, G; Golovtsov, V; Ivanov, Y; Kim, V; Kozlov, V; Levchenko, P; Obrant, G; Orishchin, E; Petrunin, A; Shcheglov, Y; Shchetkovskiy, A; Sknar, V; Smirnov, I; Sulimov, V; Tarakanov, V; Uvarov, L; Vavilov, S; Velichko, G; Volkov, S; Vorobyev, A; Andreev, Yu; Anisimov, A; Antipov, P; Dermenev, A; Gninenko, S; Golubev, N; Kirsanov, M; Krasnikov, N; Matveev, V; Pashenkov, A; Postoev, V E; Solovey, A; Toropin, A; Troitsky, S; Baud, A; Epshteyn, V; Gavrilov, V; Ilina, N; Kaftanov, V; Kolosov, V; Kossov, M; Krokhotin, A; Kuleshov, S; Oulianov, A; Safronov, G; Semenov, S; Shreyber, I; Stolin, V; Vlasov, E; Zhokin, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Petrushanko, S; Sarycheva, L; Savrin, V; Snigirev, A; Vardanyan, I; Dremin, I; Kirakosyan, M; Konovalova, N; Rusakov, S V; Vinogradov, A; Akimenko, S; Artamonov, A; Azhgirey, I; Bitioukov, S; Burtovoy, V; Grishin, V; Kachanov, V; Konstantinov, D; Krychkine, V; Levine, A; Lobov, I; Lukanin, V; Mel'nik, Y; Petrov, V; Ryutin, R; Slabospitsky, S; Sobol, A; Sytine, A; Tourtchanovitch, L; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Djordjevic, M; Jovanovic, D; Krpic, D; Maletic, D; Puzovic, J; Smiljkovic, N; Aguilar-Benitez, M; Alberdi, J; Alcaraz Maestre, J; Arce, P; Barcala, J M; Battilana, C; Burgos Lazaro, C; Caballero Bejar, J; Calvo, E; Cardenas Montes, M; Cepeda, M; Cerrada, M; Chamizo Llatas, M; Clemente, F; Colino, N; Daniel, M; De La Cruz, B; Delgado Peris, A; Diez Pardos, C; Fernandez Bedoya, C; Fernández Ramos, J P; Ferrando, A; Flix, J; Fouz, M C; Garcia-Abia, P; Garcia-Bonilla, A C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Marin, J; Merino, G; Molina, J; Molinero, A; Navarrete, J J; Oller, J C; Puerta Pelayo, J; Romero, L; Santaolalla, J; Villanueva Munoz, C; Willmott, C; Yuste, C; Albajar, C; Blanco Otano, M; de Trocóniz, J F; Garcia Raboso, A; Lopez Berengueres, J O; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Lloret Iglesias, L; Naves Sordo, H; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chuang, S H; Diaz Merino, I; Diez Gonzalez, C; Duarte Campderros, J; Fernandez, M; Gomez, G; Gonzalez Sanchez, J; Gonzalez Suarez, R; Jorda, C; Lobelle Pardo, P; Lopez Virto, A; Marco, J; Marco, R; Martinez Rivero, C; Martinez Ruiz del Arbol, P; Matorras, F; Rodrigo, T; Ruiz Jimeno, A; Scodellaro, L; Sobron Sanudo, M; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Albert, E; Alidra, M; Ashby, S; Auffray, E; Baechler, J; Baillon, P; Ball, A H; Bally, S L; Barney, D; Beaudette, F; Bellan, R; Benedetti, D; Benelli, G; Bernet, C; Bloch, P; Bolognesi, S; Bona, M; Bos, J; Bourgeois, N; Bourrel, T; Breuker, H; Bunkowski, K; Campi, D; Camporesi, T; Cano, E; Cattai, A; Chatelain, J P; Chauvey, M; Christiansen, T; Coarasa Perez, J A; Conde Garcia, A; Covarelli, R; Curé, B; De Roeck, A; Delachenal, V; Deyrail, D; Di Vincenzo, S; Dos Santos, S; Dupont, T; Edera, L M; Elliott-Peisert, A; Eppard, M; Favre, M; Frank, N; Funk, W; Gaddi, A; Gastal, M; Gateau, M; Gerwig, H; Gigi, D; Gill, K; Giordano, D; Girod, J P; Glege, F; Gomez-Reino Garrido, R; Goudard, R; Gowdy, S; Guida, R; Guiducci, L; Gutleber, J; Hansen, M; Hartl, C; Harvey, J; Hegner, B; Hoffmann, H F; Holzner, A; Honma, A; Huhtinen, M; Innocente, V; Janot, P; Le Godec, G; Lecoq, P; Leonidopoulos, C; Loos, R; Lourenço, C; Lyonnet, A; Macpherson, A; Magini, N; Maillefaud, J D; Maire, G; Mäki, T; Malgeri, L; Mannelli, M; Masetti, L; Meijers, F; Meridiani, P; Mersi, S; Meschi, E; Meynet Cordonnier, A; Moser, R; Mulders, M; Mulon, J; Noy, M; Oh, A; Olesen, G; Onnela, A; Orimoto, T; Orsini, L; Perez, E; Perinic, G; Pernot, J F; Petagna, P; Petiot, P; Petrilli, A; Pfeiffer, A; Pierini, M; Pimiä, M; Pintus, R; Pirollet, B; Postema, H; Racz, A; Ravat, S; Rew, S B; Rodrigues Antunes, J; Rolandi, G; Rovere, M; Ryjov, V; Sakulin, H; Samyn, D; Sauce, H; Schäfer, C; Schlatter, W D; Schröder, M; Schwick, C; Sciaba, A; Segoni, I; Sharma, A; Siegrist, N; Siegrist, P; Sinanis, N; Sobrier, T; Sphicas, P; Spiga, D; Spiropulu, M; Stöckli, F; Traczyk, P; Tropea, P; Troska, J; Tsirou, A; Veillet, L; Veres, G I; Voutilainen, M; Wertelaers, P; Zanetti, M; Bertl, W; Deiters, K; Erdmann, W; Gabathuler, K; Horisberger, R; Ingram, Q; Kaestli, H C; König, S; Kotlinski, D; Langenegger, U; Meier, F; Renker, D; Rohe, T; Sibille, J; Starodumov, A; Betev, B; Caminada, L; Chen, Z; Cittolin, S; Da Silva Di Calafiori, D R; Dambach, S; Dissertori, G; Dittmar, M; Eggel, C; Eugster, J; Faber, G; Freudenreich, K; Grab, C; Hervé, A; Hintz, W; Lecomte, P; Luckey, P D; Lustermann, W; Marchica, C; Milenovic, P; Moortgat, F; Nardulli, A; Nessi-Tedaldi, F; Pape, L; Pauss, F; Punz, T; Rizzi, A; Ronga, F J; Sala, L; Sanchez, A K; Sawley, M C; Sordini, V; Stieger, B; Tauscher, L; Thea, A; Theofilatos, K; Treille, D; Trüb, P; Weber, M; Wehrli, L; Weng, J; Zelepoukine, S; Amsler, C; Chiochia, V; De Visscher, S; Regenfus, C; Robmann, P; Rommerskirchen, T; Schmidt, A; Tsirigkas, D; Wilke, L; Chang, Y H; Chen, E A; Chen, W T; Go, A; Kuo, C M; Li, S W; Lin, W; Bartalini, P; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y; Lei, Y J; Lin, S W; Lu, R S; Schümann, J; Shiu, J G; Tzeng, Y M; Ueno, K; Velikzhanin, Y; Wang, C C; Wang, M; Adiguzel, A; Ayhan, A; Azman Gokce, A; Bakirci, M N; Cerci, S; Dumanoglu, I; Eskut, E; Girgis, S; Gurpinar, E; Hos, I; Karaman, T; Kayis Topaksu, A; Kurt, P; Önengüt, G; Önengüt Gökbulut, G; Ozdemir, K; Ozturk, S; Polatöz, A; Sogut, K; Tali, B; Topakli, H; Uzun, D; Vergili, L N; Vergili, M; Akin, I V; Aliev, T; Bilmis, S; Deniz, M; Gamsizkan, H; Guler, A M; Öcalan, K; Serin, M; Sever, R; Surat, U E; Zeyrek, M; Deliomeroglu, M; Demir, D; Gülmez, E; Halu, A; Isildak, B; Kaya, M; Kaya, O; Ozkorucuklu, S; Sonmez, N; Levchuk, L; Lukyanenko, S; Soroka, D; Zub, S; Bostock, F; Brooke, J J; Cheng, T L; Cussans, D; Frazier, R; Goldstein, J; Grant, N; Hansen, M; Heath, G P; Heath, H F; Hill, C; Huckvale, B; Jackson, J; Mackay, C K; Metson, S; Newbold, D M; Nirunpong, K; Smith, V J; Velthuis, J; Walton, R; Bell, K W; Brew, C; Brown, R M; Camanzi, B; Cockerill, D J A; Coughlan, J A; Geddes, N I; Harder, K; Harper, S; Kennedy, B W; Murray, P; Shepherd-Themistocleous, C H; Tomalin, I R; Williams, J H; Womersley, W J; Worm, S D; Bainbridge, R; Ball, G; Ballin, J; Beuselinck, R; Buchmuller, O; Colling, D; Cripps, N; Davies, G; Della Negra, M; Foudas, C; Fulcher, J; Futyan, D; Hall, G; Hays, J; Iles, G; Karapostoli, G; MacEvoy, B C; Magnan, A M; Marrouche, J; Nash, J; Nikitenko, A; Papageorgiou, A; Pesaresi, M; Petridis, K; Pioppi, M; Raymond, D M; Rompotis, N; Rose, A; Ryan, M J; Seez, C; Sharp, P; Sidiropoulos, G; Stettler, M; Stoye, M; Takahashi, M; Tapper, A; Timlin, C; Tourneur, S; Vazquez Acosta, M; Virdee, T; Wakefield, S; Wardrope, D; Whyntie, T; Wingham, M; Cole, J E; Goitom, I; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Munro, C; Reid, I D; Siamitros, C; Taylor, R; Teodorescu, L; Yaselli, I; Bose, T; Carleton, M; Hazen, E; Heering, A H; Heister, A; John, J St; Lawson, P; Lazic, D; Osborne, D; Rohlf, J; Sulak, L; Wu, S; Andrea, J; Avetisyan, A; Bhattacharya, S; Chou, J P; Cutts, D; Esen, S; Kukartsev, G; Landsberg, G; Narain, M; Nguyen, D; Speer, T; Tsang, K V; Breedon, R; Calderon De La Barca Sanchez, M; Case, M; Cebra, D; Chertok, M; Conway, J; Cox, P T; Dolen, J; Erbacher, R; Friis, E; Ko, W; Kopecky, A; Lander, R; Lister, A; Liu, H; Maruyama, S; Miceli, T; Nikolic, M; Pellett, D; Robles, J; Searle, M; Smith, J; Squires, M; Stilley, J; Tripathi, M; Vasquez Sierra, R; Veelken, C; Andreev, V; Arisaka, K; Cline, D; Cousins, R; Erhan, S; Hauser, J; Ignatenko, M; Jarvis, C; Mumford, J; Plager, C; Rakness, G; Schlein, P; Tucker, J; Valuev, V; Wallny, R; Yang, X; Babb, J; Bose, M; Chandra, A; Clare, R; Ellison, J A; Gary, J W; Hanson, G; Jeng, G Y; Kao, S C; Liu, F; Liu, H; Luthra, A; Nguyen, H; Pasztor, G; Satpathy, A; Shen, B C; Stringer, R; Sturdy, J; Sytnik, V; Wilken, R; Wimpenny, S; Branson, J G; Dusinberre, E; Evans, D; Golf, F; Kelley, R; Lebourgeois, M; Letts, J; Lipeles, E; Mangano, B; Muelmenstaedt, J; Norman, M; Padhi, S; Petrucci, A; Pi, H; Pieri, M; Ranieri, R; Sani, M; Sharma, V; Simon, S; Würthwein, F; Yagil, A; Campagnari, C; D'Alfonso, M; Danielson, T; Garberson, J; Incandela, J; Justus, C; Kalavase, P; Koay, S A; Kovalskyi, D; Krutelyov, V; Lamb, J; Lowette, S; Pavlunin, V; Rebassoo, F; Ribnik, J; Richman, J; Rossin, R; Stuart, D; To, W; Vlimant, J R; Witherell, M; Apresyan, A; Bornheim, A; Bunn, J; Chiorboli, M; Gataullin, M; Kcira, D; Litvine, V; Ma, Y; Newman, H B; Rogan, C; Timciuc, V; Veverka, J; Wilkinson, R; Yang, Y; Zhang, L; Zhu, K; Zhu, R Y; Akgun, B; Carroll, R; Ferguson, T; Jang, D W; Jun, S Y; Paulini, M; Russ, J; Terentyev, N; Vogel, H; Vorobiev, I; Cumalat, J P; Dinardo, M E; Drell, B R; Ford, W T; Heyburn, B; Luiggi Lopez, E; Nauenberg, U; Stenson, K; Ulmer, K; Wagner, S R; Zang, S L; Agostino, L; Alexander, J; Blekman, F; Cassel, D; Chatterjee, A; Das, S; Gibbons, L K; Heltsley, B; Hopkins, W; Khukhunaishvili, A; Kreis, B; Kuznetsov, V; Patterson, J R; Puigh, D; Ryd, A; Shi, X; Stroiney, S; Sun, W; Teo, W D; Thom, J; Vaughan, J; Weng, Y; Wittich, P; Beetz, C P; Cirino, G; Sanzeni, C; Winn, D; Abdullin, S; Afaq, M A; Albrow, M; Ananthan, B; Apollinari, G; Atac, M; Badgett, W; Bagby, L; Bakken, J A; Baldin, B; Banerjee, S; Banicz, K; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Biery, K; Binkley, M; Bloch, I; Borcherding, F; Brett, A M; Burkett, K; Butler, J N; Chetluru, V; Cheung, H W K; Chlebana, F; Churin, I; Cihangir, S; Crawford, M; Dagenhart, W; Demarteau, M; Derylo, G; Dykstra, D; Eartly, D P; Elias, J E; Elvira, V D; Evans, D; Feng, L; Fischler, M; Fisk, I; Foulkes, S; Freeman, J; Gartung, P; Gottschalk, E; Grassi, T; Green, D; Guo, Y; Gutsche, O; Hahn, A; Hanlon, J; Harris, R M; Holzman, B; Howell, J; Hufnagel, D; James, E; Jensen, H; Johnson, M; Jones, C D; Joshi, U; Juska, E; Kaiser, J; Klima, B; Kossiakov, S; Kousouris, K; Kwan, S; Lei, C M; Limon, P; Lopez Perez, J A; Los, S; Lueking, L; Lukhanin, G; Lusin, S; Lykken, J; Maeshima, K; Marraffino, J M; Mason, D; McBride, P; Miao, T; Mishra, K; Moccia, S; Mommsen, R; Mrenna, S; Muhammad, A S; Newman-Holmes, C; Noeding, C; O'Dell, V; Prokofyev, O; Rivera, R; Rivetta, C H; Ronzhin, A; Rossman, P; Ryu, S; Sekhri, V; Sexton-Kennedy, E; Sfiligoi, I; Sharma, S; Shaw, T M; Shpakov, D; Skup, E; Smith, R P; Soha, A; Spalding, W J; Spiegel, L; Suzuki, I; Tan, P; Tanenbaum, W; Tkaczyk, S; Trentadue, R; Uplegger, L; Vaandering, E W; Vidal, R; Whitmore, J; Wicklund, E; Wu, W; Yarba, J; Yumiceva, F; Yun, J C; Acosta, D; Avery, P; Barashko, V; Bourilkov, D; Chen, M; Di Giovanni, G P; Dobur, D; Drozdetskiy, A; Field, R D; Fu, Y; Furic, I K; Gartner, J; Holmes, D; Kim, B; Klimenko, S; Konigsberg, J; Korytov, A; Kotov, K; Kropivnitskaya, A; Kypreos, T; Madorsky, A; Matchev, K; Mitselmakher, G; Pakhotin, Y; Piedra Gomez, J; Prescott, C; Rapsevicius, V; Remington, R; Schmitt, M; Scurlock, B; Wang, D; Yelton, J; Ceron, C; Gaultney, V; Kramer, L; Lebolo, L M; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Adams, T; Askew, A; Baer, H; Bertoldi, M; Chen, J; Dharmaratna, W G D; Gleyzer, S V; Haas, J; Hagopian, S; Hagopian, V; Jenkins, M; Johnson, K F; Prettner, E; Prosper, H; Sekmen, S; Baarmand, M M; Guragain, S; Hohlmann, M; Kalakhety, H; Mermerkaya, H; Ralich, R; Vodopiyanov, I; Abelev, B; Adams, M R; Anghel, I M; Apanasevich, L; Bazterra, V E; Betts, R R; Callner, J; Castro, M A; Cavanaugh, R; Dragoiu, C; Garcia-Solis, E J; Gerber, C E; Hofman, D J; Khalatian, S; Mironov, C; Shabalina, E; Smoron, A; Varelas, N; Akgun, U; Albayrak, E A; Ayan, A S; Bilki, B; Briggs, R; Cankocak, K; Chung, K; Clarida, W; Debbins, P; Duru, F; Ingram, F D; Lae, C K; McCliment, E; Merlo, J P; Mestvirishvili, A; Miller, M J; Moeller, A; Nachtman, J; Newsom, C R; Norbeck, E; Olson, J; Onel, Y; Ozok, F; Parsons, J; Schmidt, I; Sen, S; Wetzel, J; Yetkin, T; Yi, K; Barnett, B A; Blumenfeld, B; Bonato, A; Chien, C Y; Fehling, D; Giurgiu, G; Gritsan, A V; Guo, Z J; Maksimovic, P; Rappoccio, S; Swartz, M; Tran, N V; Zhang, Y; Baringer, P; Bean, A; Grachov, O; Murray, M; Radicci, V; Sanders, S; Wood, J S; Zhukova, V; Bandurin, D; Bolton, T; Kaadze, K; Liu, A; Maravin, Y; Onoprienko, D; Svintradze, I; Wan, Z; Gronberg, J; Hollar, J; Lange, D; Wright, D; Baden, D; Bard, R; Boutemeur, M; Eno, S C; Ferencek, D; Hadley, N J; Kellogg, R G; Kirn, M; Kunori, S; Rossato, K; Rumerio, P; Santanastasio, F; Skuja, A; Temple, J; Tonjes, M B; Tonwar, S C; Toole, T; Twedt, E; Alver, B; Bauer, G; Bendavid, J; Busza, W; Butz, E; Cali, I A; Chan, M; D'Enterria, D; Everaerts, P; Gomez Ceballos, G; Hahn, K A; Harris, P; Jaditz, S; Kim, Y; Klute, M; Lee, Y J; Li, W; Loizides, C; Ma, T; Miller, M; Nahn, S; Paus, C; Roland, C; Roland, G; Rudolph, M; Stephans, G; Sumorok, K; Sung, K; Vaurynovich, S; Wenger, E A; Wyslouch, B; Xie, S; Yilmaz, Y; Yoon, A S; Bailleux, D; Cooper, S I; Cushman, P; Dahmes, B; De Benedetti, A; Dolgopolov, A; Dudero, P R; Egeland, R; Franzoni, G; Haupt, J; Inyakin, A; Klapoetke, K; Kubota, Y; Mans, J; Mirman, N; Petyt, D; Rekovic, V; Rusack, R; Schroeder, M; Singovsky, A; Zhang, J; Cremaldi, L M; Godang, R; Kroeger, R; Perera, L; Rahmat, R; Sanders, D A; Sonnek, P; Summers, D; Bloom, K; Bockelman, B; Bose, S; Butt, J; Claes, D R; Dominguez, A; Eads, M; Keller, J; Kelly, T; Kravchenko, I; Lazo-Flores, J; Lundstedt, C; Malbouisson, H; Malik, S; Snow, G R; Baur, U; Iashvili, I; Kharchilava, A; Kumar, A; Smith, K; Strang, M; Alverson, G; Barberis, E; Boeriu, O; Eulisse, G; Govi, G; McCauley, T; Musienko, Y; Muzaffar, S; Osborne, I; Paul, T; Reucroft, S; Swain, J; Taylor, L; Tuura, L; Anastassov, A; Gobbi, B; Kubik, A; Ofierzynski, R A; Pozdnyakov, A; Schmitt, M; Stoynev, S; Velasco, M; Won, S; Antonelli, L; Berry, D; Hildreth, M; Jessop, C; Karmgard, D J; Kolberg, T; Lannon, K; Lynch, S; Marinelli, N; Morse, D M; Ruchti, R; Slaunwhite, J; Warchol, J; Wayne, M; Bylsma, B; Durkin, L S; Gilmore, J; Gu, J; Killewald, P; Ling, T Y; Williams, G; Adam, N; Berry, E; Elmer, P; Garmash, A; Gerbaudo, D; Halyo, V; Hunt, A; Jones, J; Laird, E; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Piroué, P; Stickland, D; Tully, C; Werner, J S; Wildish, T; Xie, Z; Zuranski, A; Acosta, J G; Bonnett Del Alamo, M; Huang, X T; Lopez, A; Mendez, H; Oliveros, S; Ramirez Vargas, J E; Santacruz, N; Zatzerklyany, A; Alagoz, E; Antillon, E; Barnes, V E; Bolla, G; Bortoletto, D; Everett, A; Garfinkel, A F; Gecse, Z; Gutay, L; Ippolito, N; Jones, M; Koybasi, O; Laasanen, A T; Leonardo, N; Liu, C; Maroussov, V; Merkel, P; Miller, D H; Neumeister, N; Sedov, A; Shipsey, I; Yoo, H D; Zheng, Y; Jindal, P; Parashar, N; Cuplov, V; Ecklund, K M; Geurts, F J M; Liu, J H; Maronde, D; Matveev, M; Padley, B P; Redjimi, R; Roberts, J; Sabbatini, L; Tumanov, A; Betchart, B; Bodek, A; Budd, H; Chung, Y S; de Barbaro, P; Demina, R; Flacher, H; Gotra, Y; Harel, A; Korjenevski, S; Miner, D C; Orbaker, D; Petrillo, G; Vishnevskiy, D; Zielinski, M; Bhatti, A; Demortier, L; Goulianos, K; Hatakeyama, K; Lungu, G; Mesropian, C; Yan, M; Atramentov, O; Bartz, E; Gershtein, Y; Halkiadakis, E; Hits, D; Lath, A; Rose, K; Schnetzer, S; Somalwar, S; Stone, R; Thomas, S; Watts, T L; Cerizza, G; Hollingsworth, M; Spanier, S; Yang, Z C; York, A; Asaadi, J; Aurisano, A; Eusebi, R; Golyash, A; Gurrola, A; Kamon, T; Nguyen, C N; Pivarski, J; Safonov, A; Sengupta, S; Toback, D; Weinberger, M; Akchurin, N; Berntzon, L; Gumus, K; Jeong, C; Kim, H; Lee, S W; Popescu, S; Roh, Y; Sill, A; Volobouev, I; Washington, E; Wigmans, R; Yazgan, E; Engh, D; Florez, C; Johns, W; Pathak, S; Sheldon, P; Andelin, D; Arenton, M W; Balazs, M; Boutle, S; Buehler, M; Conetti, S; Cox, B; Hirosky, R; Ledovskoy, A; Neu, C; Phillips II, D; Ronquest, M; Yohay, R; Gollapinni, S; Gunthoti, K; Harr, R; Karchin, P E; Mattson, M; Sakharov, A; Anderson, M; Bachtis, M; Bellinger, J N; Carlsmith, D; Crotty, I; Dasu, S; Dutta, S; Efron, J; Feyzi, F; Flood, K; Gray, L; Grogg, K S; Grothe, M; Hall-Wilton, R; Jaworski, M; Klabbers, P; Klukas, J; Lanaro, A; Lazaridis, C; Leonard, J; Loveless, R; Magrans de Abril, M; Mohapatra, A; Ott, G; Polese, G; Reeder, D; Savin, A; Smith, W H; Sourkov, A; Swanson, J; Weinberg, M; Wenman, D; Wensveen, M; White, A

    2010-01-01

    In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported.

  12. A straw drift chamber spectrometer for studies of rare kaon decays

    International Nuclear Information System (INIS)

    Lang, K.; Ambrose, D.; Arroyo, C.; Bachman, M.; Connor, D.; Eckhause, M.; Ecklund, K.M.; Graessle, S.; Hamela, M.; Hamilton, S.; Hancock, A.D.; Hartman, K.; Hebert, M.; Hoff, C.H.; Hoffmann, G.W.; Irwin, G.M.; Kane, J.R.; Kanematsu, N.; Kuang, Y.; Lee, R.; Marcin, M.; Martin, R.D.; McDonough, J.; Milder, A.; Molzon, W.R.; Ouimette, D.; Pommot-Maia, M.; Proga, M.; Riley, P.J.; Ritchie, J.L.; Rubin, P.D.; Vassilakopoulos, V.I.; Ware, B.; Welsh, R.E.; Wojcicki, S.G.; Worm, S.

    2004-01-01

    We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5-mm-diameter copperized Mylar and Kapton straws, used in an experimental search for rare kaon decays. The experiment took place in the high-intensity neutral beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two analyzing dipoles, and redundant particle identification to remove backgrounds

  13. Study on a cellmap for the reconstruction of cosmic ray tracks in drift chamber

    International Nuclear Information System (INIS)

    Lei Yu; Ma Yuqian

    2005-01-01

    Taking 13 Cosmic experiment (L3+C) as an example, the authors discussed a new Cellmap to reconstruct the hit in drift chamber of magnetic spectrometer for the very inclined comic-ray tracks, and compared the reconstruction results with the standard Cellmap of L3+C. It shows that, for the very inclined cosmic-ray tracks, the new Cellmap can reconstruct more hits than the standard Cellmap, and the distribution of χ 2 of track reconstruction is also improved. (authors)

  14. Smog chamber studies on the air chemistry of biogenic hydrocarbons in the presence of ozone, NOx and SO2

    International Nuclear Information System (INIS)

    Nolting, F.; Zetzsch, C.

    1990-01-01

    The influence of SO 2 on the photochemical degradation processes of the biogenic hydrocarbon α-pinene was studied with respect to the present forest decline. For that purpose premixed air was irradiated with simulated sunlight in laboratory experiments using a modified smog chamber. The performance of a novel semi continuous analyzer for H 2 SO 4 /sulfate was tested for smog chamber studies of the transformation of SO 2 to sulfuric acid and sulfur containing aerosol. An influence of SO 2 on the formation of ozone was not detected. The rates of degradation cannot be described by gas phase reactions alone, and, in addition, they are faster in the presence of humidity. Depending on humidity, 30-50% of the consumed SO 2 can be recovered in the suspended aerosol. In the presence of 60% relative humidity the nearly exclusive product is sulfur aerosol that needs further characterization. (orig.) With 9 figs., 42 refs [de

  15. Performance studies under high irradiation and ageing properties of resistive bulk Micromegas chambers at the new CERN Gamma Irradiation Facility

    International Nuclear Information System (INIS)

    Sidiropoulou, O.; Gonzalez, B. Alvarez; Bianco, M.; Farina, E.M.; Iengo, P.; Longo, L.; Pfeiffer, D.; Wotschack, J.

    2017-01-01

    Resistive bulk Micromegas chambers, produced at CERN, have been installed at the new CERN Gamma Irradiation Facility (GIF++) in order to study the effects of ageing and to evaluate the detector behaviour under high irradiation. The chambers have an active area of 10×10 cm 2 , strip pitch of 400 μm and an amplification gap of 128 μm. We present the detector performance as a function of the background rate of up to 20 MHz/cm 2 . - Highlights: • Small-size resistive bulk Micromegas detectors have been exposed to the new GIF++. • 9 months irradiation to γ up to 20 Mhz/cm 2 . 0.09 C/cm 2 collected integrated charge. • Νo degradation of the detector performance was observed. • Muon tracks successfully reconstructed up to 68 kHz/cm 2 gamma background. • Higher background rates will be studied in the coming months.

  16. A new plant chamber facility PLUS coupled to the atmospheric simulation chamber SAPHIR

    Science.gov (United States)

    Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.

    2015-11-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been build and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees are mixed with synthetic air and are transferred to the SAPHIR chamber where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOC) can be studied in detail. In PLUS all important enviromental parameters (e.g. temperature, PAR, soil RH etc.) are well-controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leafes of the plants is constructed such that gases are exposed to FEP Teflon film and other Teflon surfaces only to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 LED panels which have an emission strength up to 800 μmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOC) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light and temperature dependent BVOC emissions are studied using six Quercus Ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus Ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental set up and the utility of the newly added plant chamber.

  17. Chamber transport

    International Nuclear Information System (INIS)

    Olson, Craig L.

    2001-01-01

    Heavy ion beam transport through the containment chamber plays a crucial role in all heavy ion fusion (HIF) scenarios. Here, several parameters are used to characterize the operating space for HIF beams; transport modes are assessed in relation to evolving target/accelerator requirements; results of recent relevant experiments and simulations of HIF transport are summarized; and relevant instabilities are reviewed. All transport options still exist, including (1) vacuum ballistic transport, (2) neutralized ballistic transport, and (3) channel-like transport. Presently, the European HIF program favors vacuum ballistic transport, while the US HIF program favors neutralized ballistic transport with channel-like transport as an alternate approach. Further transport research is needed to clearly guide selection of the most attractive, integrated HIF system

  18. Indoor Secondary Pollutants from Household Product Emissions inthe Presence of Ozone: A Bench-Scale Chamber Study

    Energy Technology Data Exchange (ETDEWEB)

    Destaillats, Hugo; Lunden, Melissa M.; Singer, Brett C.; Coleman,Beverly K.; Hodgson, Alfred T.; Weschler, Charles J.; Nazaroff, William W.

    2005-10-01

    Ozone-driven chemistry is a major source of indoor secondary pollutants of health concern. This study investigates secondary air pollutants formed from reactions between constituents of household products and ozone. Gas-phase product emissions were introduced along with ozone at constant rates into a 198-L Teflon-lined reaction chamber. Gas-phase concentrations of reactive terpenoids and oxidation products were measured. Formaldehyde was a predominant oxidation byproduct for the three studied products, with yields under most conditions of 20-30% with respect to ozone consumed. Acetaldehyde, acetone, glycolaldehyde, formic acid and acetic acid were each also detected for two or three of the products. Immediately upon mixing of reactants, a scanning mobility particle sizer detected particle nucleation events that were followed by a significant degree of ultrafine particle growth. The production of secondary gaseous pollutants and particles depended primarily on the ozone level and was influenced by other parameters such as the air-exchange rate. Hydroxyl radical concentrations in the range 0.04-200 x 10{sup 5} molecules cm{sup -3} were measured. OH concentrations were observed to vary strongly with residual ozone level in the chamber, which was in the range 1-25 ppb, as is consistent with expectations from a simplified kinetic model. In a separate test, we exposed the dry residue of two products to ozone in the chamber and observed the formation of gas-phase and particle-phase secondary oxidation products.

  19. Simulation studies for a high resolution time projection chamber at the international linear collider

    Energy Technology Data Exchange (ETDEWEB)

    Muennich, A.

    2007-03-26

    The International Linear Collider (ILC) is planned to be the next large accelerator. The ILC will be able to perform high precision measurements only possible at the clean environment of electron positron collisions. In order to reach this high accuracy, the requirements for the detector performance are challenging. Several detector concepts are currently under study. The understanding of the detector and its performance will be crucial to extract the desired physics results from the data. To optimise the detector design, simulation studies are needed. Simulation packages like GEANT4 allow to model the detector geometry and simulate the energy deposit in the different materials. However, the detector response taking into account the transportation of the produced charge to the readout devices and the effects ofthe readout electronics cannot be described in detail. These processes in the detector will change the measured position of the energy deposit relative to the point of origin. The determination of this detector response is the task of detailed simulation studies, which have to be carried out for each subdetector. A high resolution Time Projection Chamber (TPC) with gas amplification based on micro pattern gas detectors, is one of the options for the main tracking system at the ILC. In the present thesis a detailed simulation tool to study the performance of a TPC was developed. Its goal is to find the optimal settings to reach an excellent momentum and spatial resolution. After an introduction to the present status of particle physics and the ILC project with special focus on the TPC as central tracker, the simulation framework is presented. The basic simulation methods and implemented processes are introduced. Within this stand-alone simulation framework each electron produced by primary ionisation is transferred through the gas volume and amplified using Gas Electron Multipliers (GEMs). The output format of the simulation is identical to the raw data from a

  20. A preliminary inter-centre comparison study for photon, thermal neutron and epithermal neutron responses of two pairs of ionisation chambers used for BNCT

    International Nuclear Information System (INIS)

    Roca, Antoaneta; Liu, Yuan-Hao; Wojnecki, Cecile; Green, Stuart; Nievaart, Sander; Ghani, Zamir; Moss, Ray

    2009-01-01

    The dual ionisation chamber technique is the recommended method for mixed field dosimetry of epithermal neutron beams. This paper presents initial data from an ongoing inter-comparison study involving two identical pairs of ionisation chambers used at the BNCT facilities of Petten, NL and of University of Birmingham, UK. The goal of this study is to evaluate the photon, thermal neutron and epithermal neutron responses of both pairs of TE(TE) (Exradin T2 type) and Mg(Ar) (Exradin M2 type) ionisation chambers in similar experimental conditions. At this stage, the work has been completed for the M2 type chambers and is intended to be completed for the T2 type chambers in the near future.

  1. Aging study for resistive plate chambers of the CMS muon trigger detector

    CERN Document Server

    Abbrescia, M; Iaselli, G; Loddo, F; Maggi, M; Marangelli, B; Natali, S; Nuzzo, S; Pugliese, G; Ranieri, A; Romano, F; Altieri, S; Belli, G; Bruno, G; Guida, R; Ratti, S P; Riccardi, C; Torre, P; Vitulo, P

    2003-01-01

    A long-term aging test of a Resistive Plate Chamber (RPC) was carried out with an intense gamma **1**3**7Cs source. The detector was operated in avalanche mode and had the bakelite surface treated with linseed oil. After the irradiation the estimated dose, charge and fluence were approximately equal to the expected values after 10 years of operation in the CMS barrel region. During and after the irradiation, the RPC performance was monitored with cosmic muons and showed no relevant aging effects. Moreover, no variation of the bakelite resistance was observed.

  2. Aging study for resistive plate chambers of the CMS muon trigger detector

    Energy Technology Data Exchange (ETDEWEB)

    Abbrescia, M.; Colaleo, A.; Iaselli, G.; Loddo, F.; Maggi, M.; Marangelli, B.; Natali, S.; Nuzzo, S.; Pugliese, G. E-mail: gabriella.pugliese@ba.infn.it; Ranieri, A.; Romano, F.; Altieri, S.; Belli, G.; Bruno, G.; Guida, R.; Ratti, S.P.; Riccardi, C.; Torre, P.; Vitulo, P

    2003-12-01

    A long-term aging test of a Resistive Plate Chamber (RPC) was carried out with an intense gamma {sup 137}Cs source. The detector was operated in avalanche mode and had the bakelite surface treated with linseed oil. After the irradiation the estimated dose, charge and fluence were approximately equal to the expected values after 10 years of operation in the CMS barrel region. During and after the irradiation, the RPC performance was monitored with cosmic muons and showed no relevant aging effects. Moreover, no variation of the bakelite resistance was observed.

  3. Nasal hyperresponders and atopic subjects report different symptom intensity to air quality: a climate chamber study

    DEFF Research Database (Denmark)

    Bodin, Lennart; Andersson, K.; Bønløkke, Jakob Hjort

    2009-01-01

    Short-term exposure to dust and dust added with beta-(1,3)-d-glucan or aldehydes may cause sensory reactions. In random order, we exposed 36 volunteers in a climate chamber to clean air, office dust, dust with glucan, and dust with aldehydes. Three groups of subjects were exposed, eleven were non......, significance mainly because of the nasal hyperreactive group). Exposure to dust, with or without glucan or aldehydes, showed increased discomfort measured by the index for Constant Indoor Climate, and dust with glucan had a similar effect for the index for Lower Respiratory Effects. For Psychological...

  4. A Controlled-Environment Chamber for Atmospheric Chemistry Studies Using FT-IR Spectroscopy

    Science.gov (United States)

    1990-06-01

    necessary and identify by block number) FELD GROUP SUB-GROUP i >Chamber, controlled environment; long-path cell ; 07 04 FT-IR; Hydrazine decay...modification doubles the useable path length of the original multipass cell described by White (Reference 8). The pattern of images formed on the nesting...system is shown in Figure 13. 24 z C C02, Ibm, El4 944 C3 ta) caC E-4- 252 14 $4 41) 41) 0. 0 04 04 4 41) ~0 to 0.0 V-4 (A q14 0~ 1% 4-r4 $4 0 u P416 4 4

  5. Retrospective Study of Vitreous Tap Technique Using Needle Aspiration for Management of Shallow Anterior Chamber during Phacoemulsification

    Directory of Open Access Journals (Sweden)

    Ashraf Ahmed Nossair

    2017-01-01

    Full Text Available Purpose. To evaluate the technique of vitreous tap using needle aspiration for management of anterior chamber shallowness during phacoemulsification. Methods. A retrospective study included 26 eyes of 17 patients who underwent phacoemulsification in which vitreous tap was performed using a 27-gauge needle attached to a 5 ml syringe, inserted 3.5 mm from the limbus to aspirate 0.2 ml of liquefied vitreous if a cohesive (OVD failed to sufficiently deepen the anterior chamber. Results. Preoperative anterior chamber depth was 2.31 ± 0.26 mm, axial length was 21.7 ± 0.67 mm, lens thickness was 4.5 ± .19 mm, and cataract grade was 3.77 ± 1.4. Preoperative CDVA in LogMAR units was 0.98 ± 0.75. Coexisting angle closure glaucoma was present in 7 patients (26.92% preoperatively. Vitreous needle tap was successful in vitreous removal on the first attempt in 26 eyes (100%. Postoperative follow-up period was 22.88 ± 10.24 (4–39 months. The final postoperative CDVA in LogMAR units was 0.07 ± 0.1, while the final postoperative IOP was 16.54 ± 1.45 mmHg. No complications related to vitreous tap were noted. Conclusion. Vitreous needle tap is a simple, cost-effective, and safe technique for management of shallow anterior chamber in phacoemulsification.

  6. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  7. A study of an optimal technological solution for the electronics of particle position sensitive gas detectors (multiwire proportional chambers)

    International Nuclear Information System (INIS)

    Zojceski, Z.

    1997-01-01

    This work aims at optimizing the electronics for position sensitive gas detectors. The first part is a review of proportional chamber operation principles and presents the different possibilities for the architecture of the electronics. The second part involves electronic signal processing for best signal-to-noise ratio. We present a time-variant filter based on a second order base line restorer.It allows a simple pole-zero and tail cancellation at high counting rates. Also, various interpolating algorithms for cathode strip chambers have been studied. The last part reports the development of a complete electronic system, from the preamplifiers up to the readout and control interface, for the cathode strip chambers in the focal plane of the BBS Spectrometer at KVI, Holland. The system is based on application specific D-size VXI modules. In all modules, the 16-bit ADCs and FIFO memory are followed by a Digital Signal Processor, which performs data filtering and cathode induced charge interpolation. Very good analog noise performance is obtained in a multi-processor environment. (author)

  8. Study of the performance of the Micromegas chambers for the ATLAS Muon Spectrometer upgrade

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00237763; The ATLAS Muon collaboration

    2017-01-01

    Micromegas (MICRO MEsh GAseous Structure) chambers are Micro-Pattern Gaseous Detectors designed to provide a high spatial resolution in highly irradiated environments. In 2007 an ambitious long-term R&D activity was started in the context of the ATLAS experiment, at CERN: the Muon ATLAS Micromegas Activity (MAMMA). After years of tests on prototypes and technology breakthroughs, Micromegas chambers were chosen as tracking detectors for an upgrade of the ATLAS Muon Spectrometer. These novel detectors will be installed in 2018 and 2019 during the second long shutdown of the Large Hadron Collider, and will serve as precision detectors in the innermost part of the ATLAS Muon Spectrometer. Eight layers of Micromegas modules of unprecedented size, up to 3 $\\rm{{m^2}}$, will cover a surface of 150 $\\rm{{m^2}}$ for a total active area of about 1200 $\\rm{{m^2}}$. This upgrade will be crucial to ensure high quality performance for the ATLAS Muon Spectrometer in view of the third run of the Large Hadron Collider and...

  9. Performance Studies of Micromegas Chambers for the New Small Wheel Upgrade Project

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00349891; The ATLAS collaboration; Leontsinis, Stefanos

    2015-01-01

    Micromegas, an abbreviation for Micro MEsh Gaseous Structure (MM), is a robust detector with excellent spatial resolution and high rate capability. An $R\\&D$ activity, called Muon ATLAS MicroMegas Activity (MAMMA), was initiated in 2007 in order to explore the potential of the MM technology for use in the ATLAS experiment. After several years of prototyping and testing, the ATLAS collaboration has chosen the MM technology along with the small-strip Thin Gap Chambers (sTGC) for the upgrade of the inner muon station in the high-rapidity region, the so called New Small Wheel (NSW) upgrade project. It will employ eight layers of MM and eight layers of sTGC detectors per wheel. The NSW project requires fully efficient MM chambers, able to cope with the maximum expected rate of $15\\,\\mathrm{kHz/cm^2}$ featuring single plane spatial resolution better than $100\\,\\mu\\mathrm{m}$. The MM detectors will cover a total active area of $\\sim1200\\,\\mathrm{m^2}$ and will be operated in a moderate magnetic field with intens...

  10. Oxidation of a new Biogenic VOC: Chamber Studies of the Atmospheric Chemistry of Methyl Chavicol

    Science.gov (United States)

    Bloss, William; Alam, Mohammed; Adbul Raheem, Modinah; Rickard, Andrew; Hamilton, Jacqui; Pereira, Kelly; Camredon, Marie; Munoz, Amalia; Vazquez, Monica; Vera, Teresa; Rodenas, Mila

    2013-04-01

    The oxidation of volatile organic compounds (VOCs) leads to formation of ozone and SOA, with consequences for air quality, health, crop yields, atmospheric chemistry and radiative transfer. Recent observations have identified Methyl Chavicol ("MC": Estragole; 1-allyl-4-methoxybenzene, C10H12O) as a major BVOC above pine forests in the USA, and oil palm plantations in Malaysian Borneo. Palm oil cultivation, and hence MC emissions, may be expected to increase with societal food and bio fuel demand. We present the results of a series of simulation chamber experiments to assess the atmospheric fate of MC. Experiments were performed in the EUPHORE facility, monitoring stable product species, radical intermediates, and aerosol production and composition. We determine rate constants for reaction of MC with OH and O3, and ozonolysis radical yields. Stable product measurements (FTIR, PTRMS, GC-SPME) are used to determine the yields of stable products formed from OH- and O3- initiated oxidation, and to develop an understanding of the initial stages of the MC degradation chemistry. A surrogate mechanism approach is used to simulate MC degradation within the MCM, evaluated in terms of ozone production measured in the chamber experiments, and applied to quantify the role of MC in the real atmosphere.

  11. Ethiopian Journal of Environmental Studies and Management

    African Journals Online (AJOL)

    ... Ethiopian Journal of Environmental Studies and Management (EJESM) is based in the Department of Geography and Environmental Studies, Bahir Dar University, Ethiopia. Its aim is to publish original research output in the area of Geography, Ecology, Botany, Conservation studies, Food and Nutrition, Water Resources, ...

  12. Study design considerations in evaluating environmental impacts

    Science.gov (United States)

    Stan T. Lebow; Paul A. Cooper; Patricia Lebow

    2006-01-01

    The purpose of this chapter is to make the reader aware of how choices in study parameters may influence the outcome of treated-wood environmental impact evaluations. Evaluation of the leaching and environmental accumulation of preservatives from treated wood is a complex process. and many factors can influence the results of such studies. In laboratory studies, the...

  13. Numerical investigation of upper-room UVGI disinfection efficacy in an environmental chamber with a ceiling fan.

    Science.gov (United States)

    Zhu, Shengwei; Srebric, Jelena; Rudnick, Stephen N; Vincent, Richard L; Nardell, Edward A

    2013-01-01

    This study investigated the disinfection efficacy of the upper-room ultraviolet germicidal irradiation (UR-UVGI) system with ceiling fans. The investigation used the steady-state computational fluid dynamics (CFD) simulations to solve the rotation of ceiling fan with a rotating reference frame. Two ambient air exchange rates, 2 and 6 air changes per hour (ACH), and four downward fan rotational speeds, 0, 80, 150 and 235 rpm were considered. In addition, the passive scalar concentration simulations incorporated ultraviolet (UV) dose by two methods: one based on the total exposure time and average UV fluence rate, and another based on SVE3* (New Scale for Ventilation Efficiency 3), originally defined to evaluate the mean age of the air from an air supply opening. Overall, the CFD results enabled the evaluation of UR-UVGI disinfection efficacy using different indices, including the fraction of remaining microorganisms, equivalent air exchange rate, UR-UVGI effectiveness and tuberculosis infection probability by the Wells-Riley equation. The results indicated that air exchange rate was the decisive factor for determining UR-UVGI performance in disinfecting indoor air. Using a ceiling fan could also improve the performance in general. Furthermore, the results clarified the mechanism for the ceiling fan to influence UR-UVGI disinfection efficacy. © 2013 The Authors Photochemistry and Photobiology © 2013 The American Society of Photobiology.

  14. 25 CFR 212.7 - Environmental studies.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Environmental studies. 212.7 Section 212.7 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS LEASING OF ALLOTTED LANDS FOR MINERAL DEVELOPMENT General § 212.7 Environmental studies. The provisions of § 211.7 of this subchapter...

  15. Comparison of temperature rise in the pulp chamber with different light curing units: An in-vitro study

    OpenAIRE

    Rajesh Ebenezar A; Anilkumar R; Indira R; Ramachandran S; Srinivasan M

    2010-01-01

    Aims/Objectives : This in vitro study was designed to measure and compare the temperature rise in the pulp chamber with different light curing units. Materials and Methods : The study was done in two settings-in-vitro and in-vivo simulation. In in-vitro setting, 3mm and 6mm acrylic spacers with 4mm tip diameter thermocouple was used and six groups were formed according to the light curing source- 3 Quartz-Tungsten-Halogen (QTH) units and 3 Light-Emitting-Diode (LED) units. For the LED units...

  16. Comparison of temperature rise in the pulp chamber with different light curing units: An in-vitro study

    OpenAIRE

    Rajesh Ebenezar, A V; Anilkumar, R; Indira, R; Ramachandran, S; Srinivasan, M R

    2010-01-01

    Aims/Objectives: This in vitro study was designed to measure and compare the temperature rise in the pulp chamber with different light curing units. Materials and Methods: The study was done in two settings-in-vitro and in-vivo simulation. In in-vitro setting, 3mm and 6mm acrylic spacers with 4mm tip diameter thermocouple was used and six groups were formed according to the light curing source- 3 Quartz-Tungsten-Halogen (QTH) units and 3 Light-Emitting-Diode (LED) units. For the LED units, th...

  17. The Environmental Action and Philosophy Matrix: An Exploratory Study of the Environmental Attitudes of Recreation Management and Environmental Studies Students

    Science.gov (United States)

    Schultz, Jeremy R.; Simpson, Steven; Elfessi, Abdulaziz M.

    2011-01-01

    This study is a comparative analysis of the environmental philosophies of college undergraduates enrolled in a Midwestern university. Two courses were used for the research, one from a recreation management curriculum and the other from environmental studies. The study utilized a survey instrument called the Environmental Action and Philosophy…

  18. Peak nasal inspiratory flow as outcome for provocation studies in allergen exposure chambers

    DEFF Research Database (Denmark)

    Boelke, Georg; Berger, Uwe; Bergmann, Karl-Christian

    2017-01-01

    : In a randomized controlled blinded setting subjects suffering from allergic rhinitis were exposed to grass pollen, birch pollen, house dust mite and/or placebo in the GA(2)LEN chamber. Different allergen concentrations were used to evaluate symptom severities. Patients had to perform PNIF before and every 30 min...... during a challenge using a portable PNIF meter. RESULTS: 86 subjects participated in 203 challenges, altogether. House dust mite provocations caused the greatest reduction in PNIF values, followed by grass pollen and birch pollen. Provocations with every allergen or pollen concentration led...... symptoms. CONCLUSION: PNIF is a helpful and feasible tool for conducting provocation trials with allergens, especially grass pollen and house dust mite, in an AEC....

  19. SπRIT: A time-projection chamber for symmetry-energy studies

    International Nuclear Information System (INIS)

    Shane, R.; McIntosh, A.B.; Isobe, T.; Lynch, W.G.; Baba, H.; Barney, J.; Chajecki, Z.; Chartier, M.; Estee, J.; Famiano, M.; Hong, B.; Ieki, K.; Jhang, G.; Lemmon, R.; Lu, F.; Murakami, T.; Nakatsuka, N.; Nishimura, M.; Olsen, R.; Powell, W.

    2015-01-01

    A time-projection chamber (TPC) called the SAMURAI Pion-Reconstruction and Ion-Tracker (SπRIT) has recently been constructed at Michigan State University as part of an international effort to constrain the symmetry-energy term in the nuclear Equation of State (EoS). The SπRIT TPC will be used in conjunction with the SAMURAI spectrometer at the Radioactive Isotope Beam Factory (RIBF) at RIKEN to measure yield ratios for pions and other light isospin multiplets produced in central collisions of neutron-rich heavy ions, such as 132 Sn+ 124 Sn. The SπRIT TPC can function both as a TPC detector and as an active target. It has a vertical drift length of 50 cm, parallel to the magnetic field. Gas multiplication is achieved through the use of a multi-wire anode plane. Image charges, produced in the 12096 pads, are read out with the recently developed Generic Electronics for TPCs

  20. Numerical study on turbulent flow inside a channel with an extended chamber

    International Nuclear Information System (INIS)

    Lee, Young Tae; Lim, Hee Chang

    2009-01-01

    The paper presents a LES numerical simulation of turbulent flow around an extended chamber. The simulations are carried out on a series of 3-dimensional cavities placed in a turbulent boundary layer at a Reynolds number of 1.0x10 5 based on U and h, which are the velocity at the upper top of the cavity and the depth height, respectively. In order to get an appropriate solution in the Filtered Navier-Stokes equation for the incompressible flow, the computational mesh is densely attracted to the cavity surface and coarsely far-field, as this aids saving the computation cost and rapid convergence. The Boussinesq hypothesis is employed in the subgrid-scale turbulence model. In order to obtain the subgrid-scale turbulent viscosity, the Smagorinsky-Lilly SGS model is applied and the CFL number for time marching is 1.0. The results include the flow variations inside a cavity with the different sizes and shapes.

  1. A large area position-sensitive ionization chamber for heavy-ion-induced reaction studies

    CERN Document Server

    Pant, L M; Dinesh, B V; Thomas, R G; Saxena, A; Sawant, Y S; Choudhury, R K

    2002-01-01

    A large area position-sensitive ionization chamber with a wide dynamic range has been developed to measure the mass, charge and energy of the heavy ions and the fission fragments produced in heavy-ion-induced reactions. The split anode geometry of the detector makes it suitable for both particle identification and energy measurements for heavy ions and fission fragments. The detector has been tested with alpha particles from sup 2 sup 4 sup 1 Am- sup 2 sup 3 sup 9 Pu source, fission fragments from sup 2 sup 5 sup 2 Cf and the heavy-ion beams from the 14UD Mumbai Pelletron accelerator facility. Using this detector, measurements on mass and total kinetic energy distributions in heavy-ion-induced fusion-fission reactions have been carried out for a wide range of excitation energies. Results on deep inelastic collisions and mass-energy correlations on different systems using this detector setup are discussed.

  2. Study on dosimetric characteristics of ionizing chambers with an electrostatic relay

    International Nuclear Information System (INIS)

    Yuryatin, E.N.; Fominykh, V.I.; Shumshurov, V.I.; Tel'tsov, M.V.

    1979-01-01

    The metrologic characteristics of the ionization integral-pulse dosimeters with the electrostatic relay, IC-5B and IC-14 (ionization chambers) are investigated. The dosimeter sizes are as followi IC-5ng 6B -m diameter, 80 mm height; IC-14 - 42 mm diameter, 67 mm height. The ionization volume is filled with argon. The electrostatic relay converts the charge (or current) of the ionization chamber into the succession of electric pulses and so the charge (or current) measurement comes to the calculation of the pulse number. The dosimeter stability is investigated in the beam of 137 Cs γ-radiation source. Distribution of results of operation for 8 hours does not exceed 3 and 1.2%, for 6 days - 1.5 and 2% respectively for IC-5B and IC-14. Sensitivity rate at the dosimeter rotation about the symmetry axis does not exceed +-2.5% at various effective energies of 137 Cs and 60 Co γ-radiations. At the dosimeter rotation about the axis, perpendicular to the symmetry axis, the dosage sensitivity twice as much at the radiation energy lower than 10O keV. The dosimeter sensitivity in the power range of exposure doze of 0.56-195 R/h changes not more than over 5%. The dosimeter dosage sensitivity to the X-ray radiation with the effective energy of 40 keV exceeds approximately 10 times the dosage sensitivity to 137 Cs γ-radiation. The obtained results are useful at the data analysis on the radiation situation of different cosmic devices

  3. The KLOE drift chamber

    International Nuclear Information System (INIS)

    Ferrari, A.

    2002-01-01

    The design and construction of the large drift chamber of the KLOE experiment is presented. The track reconstruction is described, together with the calibration method and the monitoring systems. The stability of operation and the performance are studied with samples of e + e - , K S K L and K + K - events

  4. Summer Undergraduate Research Program: Environmental studies

    Energy Technology Data Exchange (ETDEWEB)

    McMillan, J. [ed.

    1994-12-31

    The purpose of the summer undergraduate internship program for research in environmental studies is to provide an opportunity for well-qualified students to undertake an original research project as an apprentice to an active research scientist in basic environmental research. The students are offered research topics at the Medical University in the scientific areas of pharmacology and toxicology, epidemiology and risk assessment, environmental microbiology, and marine sciences. Students are also afforded the opportunity to work with faculty at the University of Charleston, SC, on projects with an environmental theme. Ten well-qualified students from colleges and universities throughout the eastern United States were accepted into the program.

  5. Peltier-based cloud chamber

    Science.gov (United States)

    Nar, Sevda Yeliz; Cakir, Altan

    2018-02-01

    Particles produced by nuclear decay, cosmic radiation and reactions can be identified through various methods. One of these methods that has been effective in the last century is the cloud chamber. The chamber makes visible cosmic particles that we are exposed to radiation per second. Diffusion cloud chamber is a kind of cloud chamber that is cooled by dry ice. This traditional model has some application difficulties. In this work, Peltier-based cloud chamber cooled by thermoelectric modules is studied. The new model provided uniformly cooled base of the chamber, moreover, it has longer lifetime than the traditional chamber in terms of observation time. This gain has reduced the costs which spent each time for cosmic particle observation. The chamber is an easy-to-use system according to traditional diffusion cloud chamber. The new model is portable, easier to make, and can be used in the nuclear physics experiments. In addition, it would be very useful to observe Muons which are the direct evidence for Lorentz contraction and time expansion predicted by Einsteins special relativity principle.

  6. Automation and instrument control applied to an experimental study of electron transport dynamics in an avalanche mode resistive plater chamber

    International Nuclear Information System (INIS)

    Ridenti, Marco A.; Pascholati, Paulo R.

    2009-01-01

    In this work it is presented a computer based instrumentation system which was developed to perform data acquisition and integrate the control of different devices in an experimental study of electron transport dynamics in an avalanche mode resistive plate chamber detector in the Radiation Technology Center (CTR) at IPEN/CNEN-SP. System control and data acquisition was performed by a computer program called RPCLabOperator written in MatLab environment running on a LeCroy WavePro 7000 digital oscilloscope. (author)

  7. Study of microstrip gas chambers for CMS experiment and measurement of the W boson mass in the DELPHI experiment

    International Nuclear Information System (INIS)

    Ripp-Baudot, I.

    2004-06-01

    In this document the author describes 3 fields of his research activities: first, the development and validation tests of micro-strip gas chambers for the CMS experiment; secondly, the measurements of the W boson mass and width by analysing the events: e + e - → W + W - → qq-bar qq-bar whose data have been collected in the DELPHI experiment (at the LEP-2 accelerator); and thirdly, the tagging of b-jets that is an essential tool for the study of the top quark. The last chapter is dedicated to what is expected from LHC experiments concerning the properties of the quark top: mass, spin, production and decay channels

  8. landscape incorporation in the environmental impact studies

    International Nuclear Information System (INIS)

    Gutierrez G, Luz Angela

    2000-01-01

    A general overview on landscape analysis showing the two principal approaches to their study, the article emphasize on the need of taking landscape in consideration on the making of the environmental impact study of any project of development

  9. The Environmental Assessment Technique: An Empirical Study.

    Science.gov (United States)

    Overall, Jesse U., IV

    The purpose of the study was to investigate the effectiveness of Alexander Astin's Environmental Assessment Technique (EAT) in describing the environmental press at a large public university, California State University at Los Angeles. Results indicate that EAT is a very economical method for broadly describing aspects of a university's…

  10. Effect of Propafenone on the Contractile Activity of Latissimus Dorsi Muscle Isolated in an Organ Chamber: Experimental Study in Rats

    Directory of Open Access Journals (Sweden)

    Ricardo Simões

    2002-03-01

    Full Text Available OBJECTIVE: To study the effect of propafenone on the contractile function of latissimus dorsi muscle isolated from rats in an organ chamber. METHODS: We studied 20 latissimus dorsi muscles of Wistar rats and divided them into 2 groups: group I (n=10, or control group - we studied the feasibility of muscle contractility; group II (n=10, in which the contralateral muscles were grouped - we analyzed the effect of propafenone on muscle contractility. After building a muscle ring, 8 periods of sequential 2-minute baths were performed, with intervals of preprogrammed electrical stimulation using a pacemaker of 50 stimuli/min. In group II, propafenone, at the concentration of 9.8 µg/mL, was added to the bath in period 2 and withdrawn in period 4. RESULTS: In group I, no significant depression in muscle contraction occurred up to period 5 (p>0.05. In group II, a significant depression occurred in all periods, except between the last 2 periods (p0.05. CONCLUSION: Propafenone had a depressing effect on the contractile function of latissimus dorsi muscle isolated from rats and studied in an organ chamber.

  11. Studies of gaseous multiplication coefficient in isobutane using a resistive plate chamber

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Pontificia Univ. Catolica de Sao Paulo (PUC/SP), SP (Brazil); Lima, Iara B.; Vivaldini, Tulio C. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ridenti, Marco A.; Pascholati, Paulo R. [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Fisica. Lab. do Acelerador Linear; Fonte, Paulo; Mangiarotti, Alessio [Universidade de Coimbra (Portugal). Dept. de fisica. Lab. de Instrumentacao e Fisica Experimental de Particulas

    2009-07-01

    Full text: Due to the increasing demands concerning High Energy Physics, Nuclear Medicine and other Nuclear Applications about gaseous detectors operating in high electric fields, many efforts have been done about the choice of filling gases that fulfill these requirements. In this context, the electron transport parameters in gases, as the gaseous multiplication coefficient, play an important role not only for detector design but also for simulation and modeling of discharges, allowing the validation of electron impact cross-sections. In the present work the preliminary measurements of gaseous multiplication coefficient, as function of the reduced electric field (from 36V/cm.Torr until 93V/cm.Torr), for isobutane are presented. Among several filling gases, isobutane is widely used in resistive plate chambers RPCs, and other gaseous detectors, due to its timing properties. Although its characteristics, there is a lack of swarm parameters data in literature for this gas, mainly at high electric fields. The experimental method used is based on the Pulsed Townsend technique, which follows from Townsend equation solution for a uniform electric field. Considering the ratio between the current (I), measured in avalanche mode, and the primary ionization current (I{sub 0}), the effective multiplication coefficient can be determined, since alpha = d{sup -1}ln(I/I{sub 0}), where d is the gap between the electrodes. In our configuration, the experimental setup consists of two parallel plates enclosure in a stainless steel chamber at gas flow regime. The anode, is made of a high resistivity (2.10{sup 12}{omega}.cm) glass (3mm thick and 14mm diameter), while the cathode is of aluminium (40mm diameter). Primary electrons are produced by irradiating the cathode with a nitrogen laser (LTB MNL200-LD) and are accelerated toward the anode by means of a high voltage power supply (Bertan 225-30). In order to validate the technique and to analyze effects of non-uniformity, results for

  12. Doriot Climatic Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...

  13. Increases of Chamber Height and Base Diameter Have Contrasting Effects on Grazing Rate of Two Cladoceran Species: Implications for Microcosm Studies

    Science.gov (United States)

    Pan, Ying; Zhang, Yunshu; Peng, Yan; Zhao, Qinghua; Sun, Shucun

    2015-01-01

    Aquatic microcosm studies often increase either chamber height or base diameter (to increase water volume) to test spatial ecology theories such as “scale” effects on ecological processes, but it is unclear whether the increase of chamber height or base diameter have the same effect on the processes, i.e., whether the effect of the shape of three-dimensional spaces is significant. We orthogonally manipulated chamber height and base diameter and determined swimming activity, average swimming velocity and grazing rates of the cladocerans Daphnia magna and Moina micrura (on two algae Scenedesmus quadricauda and Chlorella vulgaris; leading to four aquatic algae-cladoceran systems in total) under different microcosm conditions. Across all the four aquatic systems, increasing chamber height at a given base diameter significantly decreased the duration and velocity of horizontal swimming, and it tended to increase the duration but decrease the velocity of vertical swimming. These collectively led to decreases in both average swimming velocity and grazing rate of the cladocerans in the tall chambers (at a given base diameter), in accordance with the positive relationship between average swimming velocity and grazing rate. In contrast, an increase of base diameter at a given chamber height showed contrasting effects on the above parameters. Consistently, at a given chamber volume increasing ratio of chamber height to base diameter decreased the average swimming velocity and grazing rate across all the aquatic systems. In general, increasing chamber depth and base diameter may exert contrasting effects on zooplankton behavior and thus phytoplankton-zooplankton interactions. We suggest that spatial shape plays an important role in determining ecological process and thus should be considered in a theoretical framework of spatial ecology and also the physical setting of aquatic microcosm experiments. PMID:26273836

  14. The little holographic bubble chambers

    International Nuclear Information System (INIS)

    Herve, A.

    1983-01-01

    The lifetime study of the charmed particles has readvanced the idea to use holography for the little fast-cycle bubble chambers. A pilot experiment has been realised in 1982 with a little bubble chamber filled up with freon-115. 40000 holograms have been recorded [fr

  15. Impact of choice of future climate change projection on growth chamber experimental outcomes: a preliminary study in potato

    Science.gov (United States)

    Leisner, Courtney P.; Wood, Joshua C.; Vaillancourt, Brieanne; Tang, Ying; Douches, Dave S.; Robin Buell, C.; Winkler, Julie A.

    2017-11-01

    Understanding the impacts of climate change on agriculture is essential to ensure adequate future food production. Controlled growth experiments provide an effective tool for assessing the complex effects of climate change. However, a review of the use of climate projections in 57 previously published controlled growth studies found that none considered within-season variations in projected future temperature change, and few considered regional differences in future warming. A fixed, often arbitrary, temperature perturbation typically was applied for the entire growing season. This study investigates the utility of employing more complex climate change scenarios in growth chamber experiments. A case study in potato was performed using three dynamically downscaled climate change projections for the mid-twenty-first century that differ in terms of the timing during the growing season of the largest projected temperature changes. The climate projections were used in growth chamber experiments for four elite potato cultivars commonly planted in Michigan's major potato growing region. The choice of climate projection had a significant influence on the sign and magnitude of the projected changes in aboveground biomass and total tuber count, whereas all projections suggested an increase in total tuber weight and a decrease in specific gravity, a key market quality trait for potato, by mid-century. These results demonstrate that the use of more complex climate projections that extend beyond a simple incremental change can provide additional insights into the future impacts of climate change on crop production and the accompanying uncertainty.

  16. Studies of cosmic ray events in ATLAS sTGC muon chamber prototypes

    CERN Document Server

    AUTHOR|(CDS)2097847; Warburton, Andreas

    Four years after its first long shutdown in 2015, the Large Hadron Collider (LHC) will be shut down once more for a luminosity upgrade. During that time, the ATLAS detector on the LHC ring will also follow an upgrade program, one upgrade being the replacement of the Small Muon Wheels for a New Small Wheel containing small-strip Thin Gap Chambers (sTGCs). The sTGCs built in Canada will be tested at McGill University before their installation in ATLAS. A testing facility has been constructed and a 40 × 60 cm^2 sTGC prototype has been used to deliver preliminary measurements from cosmic rays. This thesis will present the development of a robust tracking algorithm which can handle extra clusters and multiple tracks in an sTGC detector. This algorithm also categorizes events based on their number of clusters and tracks. By modifying the trigger time window of the sTGC prototype, the evolution of the distribution of events over this categorization is shown.

  17. Study of D+ → K-π+π+ selection using the vertex drift chamber

    International Nuclear Information System (INIS)

    Hayes, K.

    1986-01-01

    Use of the vertex chamber information allows us to select D + → K - α + α + decays in Z → c anti c (Z → b anti b) events with an overall efficiency of about 15% (9%) for a signal-to-background ratio of about 4 (2). The physics which can be done with these selected decays depends on the size of the Z sample. In a sample of 10,000 hadronic Z decays, we could expect to tag about 16 D + from Z → c anti c and 11 D + from Z → b anti b events. There would be a few clean examples of b → c cascade decays where both decay vertices are well measured. With 100,000 Z decays, a good measurement of the D + production rate and x/sub D/ distribution in Z → c anti c and Z → b anti b decays could be made. We also may be able to make a reasonable measurement of the fraction of D + which have neutral parents. The D + sample could be combined with other b and c quark tagged samples to measure the Z decay assymmetry. With 1,000,000 Z decays we would have a fair chance to measure the average D + parent lifetime in Z → b anti b events. If the fraction of D + decays having neutral parents is sufficiently close to one, we could measure the charged and neutral B lifetimes

  18. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  19. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1980-01-01

    A multi-chambered ionisation detector enables the amount of radiation entering each chamber from a single radioactive, eg β, source to be varied by altering the proportion of the source protruding into each chamber. Electrodes define chambers and an extended radioactive source is movable to alter the source length in each chamber. Alternatively, the source is fixed relative to outer electrodes but the central electrode may be adjusted by an attached support altering the chamber dimensions and hence the length of source in each. Also disclosed are a centrally mounted source tiltable towards one or other chamber and a central electrode tiltable to alter chamber dimensions. (U.K.)

  20. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  1. Comparison of Geometrical Layouts for a Multi-Box Aerosol Model from a Single-Chamber Dispersion Study

    Directory of Open Access Journals (Sweden)

    Alexander C. Ø. Jensen

    2018-04-01

    Full Text Available Models are increasingly used to estimate and pre-emptively calculate the occupational exposure of airborne released particulate matter. Typical two-box models assume instant and fully mixed air volumes, which can potentially cause issues in cases with fast processes, slow air mixing, and/or large volumes. In this study, we present an aerosol dispersion model and validate it by comparing the modelled concentrations with concentrations measured during chamber experiments. We investigated whether a better estimation of concentrations was possible by using different geometrical layouts rather than a typical two-box layout. A one-box, two-box, and two three-box layouts were used. The one box model was found to underestimate the concentrations close to the source, while overestimating the concentrations in the far field. The two-box model layout performed well based on comparisons from the chamber study in systems with a steady source concentration for both slow and fast mixing. The three-box layout was found to better estimate the concentrations and the timing of the peaks for fluctuating concentrations than the one-box or two-box layouts under relatively slow mixing conditions. This finding suggests that industry-relevant scaled volumes should be tested in practice to gain more knowledge about when to use the two-box or the three-box layout schemes for multi-box models.

  2. Ethiopian Journal of Environmental Studies and Management

    African Journals Online (AJOL)

    The Ethiopian Journal of Environmental Studies and Management (EJESM) is based in ... Remote sensing and gis applications in determining shoreline and surface ... Assessment Of Labile Metals In Effluents From Lubricating Oil Company In ...

  3. Application of radiotracers in environmental studies

    International Nuclear Information System (INIS)

    Rathore, V.S.

    1994-01-01

    An attempt has been made to present recently emerging trends in the applicability of radiotracers in environmental studies. Since the topic is of general interest and still in the infancy, basic aspects of sampling, instrumentation and methodology are also covered

  4. An improvement study on the closed chamber distillation system for recovery of renewable salts from salt wastes containing radioactive rare earth compounds

    International Nuclear Information System (INIS)

    Eun, H.C.; Cho, Y.Z.; Lee, T.K.; Kim, I.T.; Park, G.I.; Lee, H.S.

    2013-01-01

    In this paper, an improvement study on the closed chamber distillation system for recovery of renewable salts from salt wastes containing radioactive rare earth compounds was performed to determine optimum operating conditions. It was very important to maintain the pressure in the distillation chamber below 10 Torr for a high efficiency (salt recovery >99 %) of the salt distillation. This required increasing the salt vaporization and condensation rates in the distillation system. It was confirmed that vaporization and condensation rates could be improved controlling the given temperature of top of the condensation chamber. In the distillation tests of the salt wastes containing rare earth compounds, the operation time at a given temperature was greatly reduced changing the given temperature of top of the condensation chamber from 780 to 700 deg C. (author)

  5. Radiological assessments, environmental monitoring, and study design

    International Nuclear Information System (INIS)

    Hansen, W.R.; Elle, D.R.

    1980-01-01

    Studies of the behavior of transuranic elements in the environment form the basic data for applied programs in radiological assessment, environmental monitoring, derivation of radiation-protection standards, and environmental impact statements. This chapter introduces some of the major information requirements of these applications of transuranic research data. Characteristics of the source terms from nuclear activities usually are needed for an analysis of environmental pathways or deployment of monitoring systems. Major inhalation and ingestion pathways are considered in assessments of hazards from transuranics and are discussed from the viewpoint of research needed

  6. The organization of nuclear plants environmental studies

    International Nuclear Information System (INIS)

    Le Marechal, M.

    1980-01-01

    The author first defines the objectives of environmental studies. Next, he describes the scope and organization of sites studies as well as biological and radioecological general studies. At last, he puts forward the available means that are used for such studies and the different offices responsible for their achievement [fr

  7. Laser damage study of material of the first wall of target chamber of the future laser Megajoule

    International Nuclear Information System (INIS)

    Dubern, Christelle

    1999-01-01

    Study on damage of carbon-like, boron carbide, and stainless steel materials by ultraviolet laser light, has been carried out at CEA/CESTA in France. This work was performed to help designing and dimensioning the target chamber of the future Laser MegaJoule (LMJ) facility to be used for Inertial Confinement Fusion research. The study revealed that depending the laser fluence, the considered materials were ablated in different manners. lt was demonstrated that at low fluence, damage of carbon-like and boron carbide occurs through a thermal-mechanical mechanism resulting in sputtering of material. At higher fluence, damage was driven by a thermal mechanism, dissipating heat inside material until phase change developed. For stainless steel material, failures were the result of heat absorption associated to physical changes only. To explain and validate the proposed mechanisms, theoretical and experimental works were performed and satisfactory results came out. (author) [fr

  8. Technical Note: A numerical test-bed for detailed ice nucleation studies in the AIDA cloud simulation chamber

    Directory of Open Access Journals (Sweden)

    R. J. Cotton

    2007-01-01

    Full Text Available The AIDA (Aerosol Interactions and Dynamics in the Atmosphere aerosol and cloud chamber of Forschungszentrum Karlsruhe can be used to test the ice forming ability of aerosols. The AIDA chamber is extensively instrumented including pressure, temperature and humidity sensors, and optical particle counters. Expansion cooling using mechanical pumps leads to ice supersaturation conditions and possible ice formation. In order to describe the evolving chamber conditions during an expansion, a parcel model was modified to account for diabatic heat and moisture interactions with the chamber walls. Model results are shown for a series of expansions where the initial chamber temperature ranged from −20°C to −60°C and which used desert dust as ice forming nuclei. During each expansion, the initial formation of ice particles was clearly observed. For the colder expansions there were two clear ice nucleation episodes. In order to test the ability of the model to represent the changing chamber conditions and to give confidence in the observations of chamber temperature and humidity, and ice particle concentration and mean size, ice particles were simply added as a function of time so as to reproduce the observations of ice crystal concentration. The time interval and chamber conditions over which ice nucleation occurs is therefore accurately known, and enables the model to be used as a test bed for different representations of ice formation.

  9. Hybrid-bubble-chamber study of nucleon diffractive dissociation in 14-GeV/c π+-p collisions

    International Nuclear Information System (INIS)

    Chadwick, G.B.; Carroll, J.T.; Chaloupka, V.; Ballam, J.; Bouchez, J.; Herquet, P.; Linglin, D.; Moffeit, K.C.; Stevens, R.; Davidson, V.; Firestone, A.; Nagy, F.; Peck, C.; Rosenfeld, L.; Ely, R.; Grether, D.; Oddone, P.

    1978-01-01

    Two experiments to study the low-mass diffractive enhancement recoiling against a fast forward pion from π + p and π - p collisions at 14 GeV/c are described. Photographs of the SLAC 40-in. hydrogen bubble chamber were triggered by a downstream spectrometer when the missing mass, calculated on-line, was above 1.1 GeV. Evidence for a nonresonant mass peak at 1.35 GeV is presented, as well as for production of resonances at about 1.5 and 1.68 GeV. The data are presented as distributions in mass and momentum transfer, as well as moments and isocline plots of the decay angular distributions. Model-independent features are emphasized

  10. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....

  11. 846 Department of Geography and Environmental Studies

    African Journals Online (AJOL)

    USER

    2015-10-23

    Oct 23, 2015 ... Ethiopian Journal of Environmental Studies & Management 8(Suppl. 1): 846 – 854 ... explain causes for regional variations of road development. Secondary ... stock road network was 6400 km in 1951 .... Figure 1: Growth of Rural and urban Roads in Ethiopia, 1992-2009 ..... Zone: A Case Study of Ethiopia”.

  12. Sensitivity of gaseous xenon ionisation chambers (1961)

    International Nuclear Information System (INIS)

    Schuhl, C.

    1960-01-01

    It seems advantageous to fill an ionization chamber with xenon gas when this chamber is used for measuring a low intensity and high energy electron or positron beam, or monitoring a gamma beam. In the study of 5 to 50 MeV electrons, xenon allows for the ionization chamber yield, an improvement of a factor 4,5. (author) [fr

  13. Chemical and physical transformations of organic aerosol from the photo-oxidation of open biomass burning emissions in an environmental chamber

    Science.gov (United States)

    C. J. Hennigan; M. A. Miracolo; G. J. Engelhart; A. A. May; A. A. Presto; T. Lee; A. P. Sullivan; G. R. McMeeking; H. Coe; C. E. Wold; W.-M. Hao; J. B. Gilman; W. C. Kuster; J. de Gouw; B. A. Schichtel; J. L. Collett; S. M. Kreidenweis; A. L. Robinson

    2011-01-01

    Smog chamber experiments were conducted to investigate the chemical and physical transformations of organic aerosol (OA) during photo-oxidation of open biomass burning emissions. The experiments were carried out at the US Forest Service Fire Science Laboratory as part of the third Fire Lab at Missoula Experiment (FLAME III). We investigated emissions from 12 different...

  14. Running a marathon from -45°C to +55°C in a climate chamber: a case study.

    Science.gov (United States)

    Kälin, Kaspar; Knechtle, Beat; Rüst, Christoph Alexander; Mydlak, Karsten; Rosemann, Thomas

    2012-01-01

    We describe a runner who completed a self-paced marathon (42.195 km) in a climate chamber with a temperature difference of 100°C, starting at an ambient temperature (Tambient) of -45°C and finishing at an Tambient of +55°C. Tambient was set at -45°C at the start, and was steadily increased at a rate of 1°C at 4.5-minute intervals to +55°C. Before the start, after every 10.5 km, and at the end of the marathon, body mass, urine, and sweat production were measured and samples of venous blood and urine were collected. The runner's temperature was recorded every 10 seconds at four sites, ie, the rectum for body core temperature (Tcore), and at the forehead, right wrist, and right ankle for surface temperatures (Tskin). The subject took 6.5 hours to complete the marathon, during which Tcore varied by 0.9°C (start 37.5°C, peak 38.4°C). The largest difference (∆) of Tskin was recorded at the ankle (∆16°C). The calculated amount of sweat produced increased by 888% from baseline. In the blood samples, myoglobin (+250%) showed the highest change. Of the pituitary hormones, somatotropic hormone (+391%) and prolactin (+221%) increased the most. Regarding fluid regulation hormones, renin (+1145%) and aldosterone (+313%) showed the greatest increase. These results show that running a marathon in a climate chamber with a total ∆Tambient of 100°C is possible, and that the Tambient to Tcore relationship is maintained. These results may offer insight into regulatory mechanisms to avoid hypothermia and hyperthermia. The same study is to be performed using more subjects with the same characteristics to validate the present findings.

  15. The OPAL vertex drift chamber

    International Nuclear Information System (INIS)

    Carter, J.R.; Elcombe, P.A.; Hill, J.C.; Roach, C.M.; Armitage, J.C.; Carnegie, R.K.; Estabrooks, P.; Hemingway, R.; Karlen, D.; McPherson, A.; Pinfold, J.; Roney, J.M.; Routenburg, P.; Waterhouse, J.; Hargrove, C.K.; Klem, D.; Oakham, F.G.; Carter, A.A.; Jones, R.W.L.; Lasota, M.M.B.; Lloyd, S.L.; Pritchard, T.W.; Wyatt, T.R.

    1990-01-01

    A high precision vertex drift chamber has been installed in the OPAL experiment at LEP. The design of the chamber and the associated readout electronics is described. The performance of the system has been studied using cosmic ray muons and the results of these studies are presented. A space resolution of 50 μm in the drift direction is obtained using the OPAL central detector gas mixture at 4 bar. (orig.)

  16. Nuclear design considerations for Z-IFE chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W.R. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States)]. E-mail: meier5@llnl.gov; Schmitt, R.C. [Bettis Atomic Power Laboratory, Pittsburgh, PA 15203 (United States); Abbott, R.P. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States); Latkowski, J.F. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States); Reyes, S. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States)

    2006-02-15

    Z-pinch driven IFE (Z-IFE) requires the design of a repetitive target insertion system that allows coupling of the pulsed power to the target with adequate standoff, and a chamber that can withstand blast and radiation effects from large yield targets. The present strategy for Z-IFE is to use high yield targets ({approx}2-3 GJ/shot), low repetition rate per chamber ({approx}0.1 Hz), and 10 chambers per power plant. In this study, we propose an alternative power plant configuration that uses very high yield targets (20 GJ/shot) in a single chamber operating at 0.1 Hz. A thick-liquid-wall chamber is proposed to absorb the target emission (X-rays, debris and neutrons) and mitigate the blast effects on the chamber wall. The target is attached to the end of a conical shaped recyclable transmission line (RTL) made from a solid coolant (e.g., frozen flibe), or a material that is easily separable from the coolant (e.g., steel). The RTL/target assembly is inserted through a single opening at the top of the chamber for each shot. This study looks at the RTL material choice from a safety and environmental point of view. Materials were assessed according to waste disposal rating (WDR) and contact dose rate (CDR). Neutronics calculations, using the TART2002 Monte Carlo code from Lawrence Livermore National Laboratory (LLNL), were performed for the RTL and Z-IFE chamber, and key results reported here.

  17. Dorsal skinfold chamber models in mice

    Directory of Open Access Journals (Sweden)

    Schreiter, Jeannine

    2017-07-01

    Full Text Available Background/purpose: The use of dorsal skinfold chamber models has substantially improved the understanding of micro-vascularisation in pathophysiology over the last eight decades. It allows pathophysiological studies of vascularisation over a continuous period of time. The dorsal skinfold chamber is an attractive technique for monitoring the vascularisation of autologous or allogenic transplants, wound healing, tumorigenesis and compatibility of biomaterial implants. To further reduce the animals’ discomfort while carrying the dorsal skinfold chamber, we developed a smaller chamber (the Leipzig Dorsal Skinfold Chamber and summarized the commercial available chamber models. In addition we compared our model to the common chamber. Methods: The Leipzig Dorsal Skinfold Chamber was applied to female mice with a mean weight of 22 g. Angiogenesis within the dorsal skinfold chamber was evaluated after injection of fluorescein isothiocyanate dextran with an Axio Scope microscope. The mean vessel density within the dorsal skinfold chamber was assessed over a period of 21 days at five different time points. The gained data were compared to previous results using a bigger and heavier dorsal skinfold model in mice. A PubMed and a patent search were performed and all papers related to “dorsal skinfold chamber” from 1 of January 2006 to 31 of December 2015 were evaluated regarding the dorsal skinfold chamber models and their technical improvements. The main models are described and compared to our titanium Leipzig Dorsal Skinfold Chamber model.Results: The Leipzig Dorsal Skinfold Chamber fulfils all requirements of continuous models known from previous chamber models while reducing irritation to the mice. Five different chamber models have been identified showing substantial regional diversity. The newly elaborated titanium dorsal skinfold chamber may replace the pre-existing titanium chamber model used in Germany so far, as it is smaller and lighter

  18. A compact multi-chamber setup for degradation and lifetime studies of organic solar cells

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Jørgensen, Mikkel; Krebs, Frederik C

    2011-01-01

    A controlled atmosphere setup designed for long-term degradation studies of organic solar cells under illumination is presented. The setup was designed with ease-of-use and compactness in mind and allows for multiple solar cells distributed on four glass substrates to be studied in four different...

  19. Jupiter Environmental Research & Field Studies Academy.

    Science.gov (United States)

    Huttemeyer, Bob

    1996-01-01

    Describes the development and workings of the Jupiter Environmental Research and Field Studies Academy that focuses on enabling both teachers and students to participate in real-life learning experiences. Discusses qualifications for admittance, curriculum, location, ongoing projects, students, academics, preparation for life, problem solving, and…

  20. Tortuguero Bay [Puerto Rico] environmental studies

    International Nuclear Information System (INIS)

    Wood, E.D.; Youngbluth, M.J.; Nutt, M.E.; Yoshioka, P.; Canoy, M.J.

    1975-01-01

    Site selection surveys and environmental research studies of seven coastal sites in Puerto Rico for construction of power generating facilities were carried out. Data are presented on the physical, chemical, and geological parameters of the Tortuguero Bay site, and the ecological parameters of zooplankton, benthic invertebrates, plant and fish communities. (U.S.)

  1. Ethiopian Journal of Environmental Studies and Management ...

    African Journals Online (AJOL)

    Ethiopian Journal of Environmental Studies and Management: Advanced Search ... AND is implied); Combine multiple words with OR to find articles containing either term; e.g., education OR research; Use parentheses to create more complex queries; e.g., archive ((journal OR conference) NOT theses); Search for an exact ...

  2. The central drift chamber of the SAPHIR detector - implementation into the experiment and study of its properties

    International Nuclear Information System (INIS)

    Haas, K.M.

    1992-01-01

    At the Bonn accelerator facility ELSA the large solid angle detector SAPHIR was built for the investigation of photon induced reactions. A main component of SAPHIR is the central drift chamber (CDC) matching the magneto gap of 1m 3 . The diameter of the in total 1828 hexagonal drift cells is about 18 mm. The subject of this paper is the implementation of the CDC in the experiment. After the description of the hardware follows the presentation of the software tools for filtering and monitoring the data, which have been developed and tested. An algorithm for extracting the space time relationship is presented. The properties of the chamber with an improved gas mixture (Helium/Neon/Isobutane8 21.25:63.75:15) have been investigated. A spatial resolution of about 200 μm was achieved. The efficiency of the chamber is 97% at a tagged photon of 5x10 4 per second crossing the chamber. (orig.) [de

  3. Systematic studies on the reconstruction efficiency and accuracy of a track drift chamber

    International Nuclear Information System (INIS)

    Appelshaeuser, H.

    1993-02-01

    The author has studied the reconstruction efficiency of the NA35-TPC by means of a simulation of the tracks by means of laser radiation. He has obtained results on the diffusion constant and the track resolution. (HSI) [de

  4. Vacuum Chamber Construction and Contamination Study of A Micro Pulsed Plasma Thruster

    National Research Council Canada - National Science Library

    Debevec, Jacob H

    2006-01-01

    .... This study examines the deposition profile and rate of particle emission from the thruster so that satellite designers understand any potential contamination issues with sensitive instruments and solar panels...

  5. Short communication: Assessment of activity patterns of growing rabbits in a flux-controlled chamber

    Directory of Open Access Journals (Sweden)

    Irene Olivas

    2013-06-01

    Full Text Available Flux-controlled and metabolic chambers are often used for nutritional and environmental studies. However, the potential alterations of animal behaviour and welfare are so far not fully understood. In consequence, this study had 2 main objectives: to assess potential alterations of animal activity pattern and time budget inside a flux chamber, and to assess the importance of the “rearing up” behaviour. To this end, 10 growing rabbits of different ages (from 1 to 5 wk of the growing period were housed inside a flux chamber. Their activity was continuously recorded and assessed, determining the frequency and duration of 8 different behaviours: lying, sleeping, sitting, eating, drinking, walking, rearing up and others. Nocturnal rabbit behaviour and time budget were not altered inside the chamber if compared to previously described rabbit activity under conventional cages. In addition, rabbits in this experiment presented a tendency to perform “rearing up” when housed inside the flux chamber.

  6. A whole-tree chamber system for examining tree-level physiological responses of field-grown trees to environmental variation and climate change.

    Science.gov (United States)

    Medhurst, Jane; Parsby, Jan; Linder, Sune; Wallin, Göran; Ceschia, Eric; Slaney, Michelle

    2006-09-01

    A whole-tree chamber (WTC) system was installed at Flakaliden in northern Sweden to examine the long-term physiological responses of field-grown 40-year-old Norway spruce trees [Picea abies (L.) Karst.] to climate change. The WTCs were designed as large cuvettes to allow the net tree-level CO(2) and water fluxes to be measured on a continuous basis. A total of 12 WTCs were used to impose combinations of atmospheric carbon dioxide concentration, [CO(2)], and air temperature treatments. The air inside the ambient and elevated [CO(2)] WTCs was maintained at 365 and 700 micromol mol(-1), respectively. The air temperature inside the ambient temperature WTCs tracked air temperature outside the WTCs. Elevated temperatures were altered on a monthly time-step and ranged between +2.8 and +5.6 degrees C above ambient temperature. The system allowed continuous, long-term measurement of whole-tree photosynthesis, night-time respiration and transpiration. The performance of the WTCs was assessed using winter and spring data sets. The ability of the WTC system to measure tree-level physiological responses is demonstrated. All WTCs displayed a high level of control over tracking of air temperatures. The set target of 365 micromol mol(-1) in the ambient [CO(2)] chambers was too low to be maintained during winter because of tree dormancy and the high natural increase in [CO(2)] over winter at high latitudes such as the Flakaliden site. Accurate control over [CO(2)] in the ambient [CO(2)] chambers was restored during the spring and the system maintained the elevated [CO(2)] target of 700 micromol mol(-1) for both measurement periods. Air water vapour deficit (VPD) was accurately tracked in ambient temperature WTCs. However, as water vapour pressure in all 12 WTCs was maintained at the level of non-chambered (reference) air, VPD of elevated temperature WTCs was increased.

  7. Study of abrasive wear process of lining of grinding chamber of vortex-acoustic disperser

    Science.gov (United States)

    Perelygin, D. N.

    2018-03-01

    The theoretical and experimental studies of the process of gas-abrasive wear of the lining of a vortex-acoustic disperser made it possible to establish the conditions and patterns of their occurrence and also to develop proposals for its reduction.

  8. Study on alumina-alumina brazing for application in vacuum chambers of proton synchrotron

    International Nuclear Information System (INIS)

    Yadav, D.P.; Kaul, R.; Ganesh, P.; Shiroman, Ram; Tiwari, Pragya; Sridhar, R.; Kukreja, L.M.

    2013-01-01

    The paper describes an experimental study to standardize vacuum brazing process to obtain satisfactory high purity alumina brazed joints for application in rapid cycle proton synchrotron machine. Two different brazing routes, adopted for making alumina-alumina brazed joints, included (i) multi-step Mo-Mn metallization and brazing with BVAg-8 alloy and (ii) advanced single-step active brazing with CuSil-ABA alloy. Brazed alumina specimens, prepared by both the routes, yielded ultra high vacuum compatible, helium leak tight and bakeable joints. Active-brazed specimens exhibited satisfactory strength values in tensile and four-point bend tests. Metallized-brazed specimens, although exhibited relatively lower tensile strength than the targeted value, displayed satisfactory flexural strength in four-point bend test. The results of the study demonstrated that active brazing is the simple and cost effective alternative to conventional metallization route for producing satisfactory brazed joints for application in rapid cycle proton synchrotron machine. (author)

  9. Study of gas emission from the internal chambers of cryogenic equipment

    International Nuclear Information System (INIS)

    Matyash, Y.I.; Fel'dman, R.G.; Ivakhnenko, Z.N.; Myasnikov, V.M.

    1986-01-01

    One of the methods of improving the efficiency of cryogenic gas equipment (CGE) is adsorption purification of the working medium. The type and quantity of adsorben can be decided after knowing the qualitative and quantitative nature of gas emissions. Gas emissions were studied by the chromatographic method using a heat-conduction detectory. This method made it possible to determine simultaneously the impurities which differ significantly in terms of physicochemical properties. It was established that carbon dioxide and hydrocarbons are continuously emitted in the gaseous medium of the CGE at a constant rate. For the type of machine which was studied, the rates of gas emission were as follows: carbon dioxide and ethane - 0.2 mg/h; ethylene and methane - 0.1 mg/h; propylene, N-butane, and isobutane - 0.2 mg/h

  10. Studies of MicroMeGas Chambers for the New Small Wheel using Cosmic Muons

    CERN Document Server

    Klapdor-kleingrothaus, Thorwald; The ATLAS collaboration

    2016-01-01

    Micromesh Gaseous Detectors (MicroMeGas) will be implemented in the ATLAS detector in the framework of the New Small Wheel Upgrade during the long shut down II in 2019/20. These detectors are used for position measurement and have a high spatial resolution of 100 μm. In parallel to the ongoing constructions of the later modules, additional performance studies with small MicroMeGas prototypes of a size of 10 × 10 cm$^2$ are performed. These studies include a cosmic muon test setup in combination with a scalable readout system, such that the influences of variations in the pressure of the operation gas or changes in the humidity at the lower ppm level to the detector performance are investigated. These parameters will impact the later design of the slow control system at the New Small Wheel in ATLAS.

  11. Studies of MicroMegas Chamber for the New Small Wheel using Cosmic Muons

    CERN Document Server

    Klapdor-kleingrothaus, Thorwald; The ATLAS collaboration

    2016-01-01

    Micromesh Gaseous (MicroMegas) Detectors will be implemented in the ATLAS detector in the framework of the New Small Wheel Upgrade during the long shut down II in 2019/20. These detectors are used for position measurement and have a high spatial resolution of 100$\\mu$m. In parallel to the ongoing constructions of the later modules, additional performance studies with small MicroMegas prototypes of a size of 10 $\\times$ 10 cm$^2$ are performed. The studies include a cosmic muon test stand in combination with a scalable readout system, such that the influences of variations in the pressure of the operation gas or changes in the humidity at the lower ppm level to the detector performance are investigated. These parameters will impact the later design of detector slow control system at the New Small Wheel in ATLAS.

  12. Study on out-gassing by baking and glow discharge during wall conditioning of vacuum chamber

    International Nuclear Information System (INIS)

    Wang Zhiwen; Wei Weixing; Zhao Yuanqing; He Yanhe; Liao Yikui

    2007-01-01

    The model of out-gassing by baking and glow discharge cleaning (GDC) is set up. The properties of them are studied. Out-gassing by baking is from bulk and it obeys the diffusion equation. Out-gassing of glow discharge cleaning is mainly on surface, it is inducement out-gassing by sputtering. Thus the properties of out-gassing for baking and GDC on the HL-1M tokamak are analyzed. Some empirical formulas are given. (authors)

  13. A two-dimensional numerical study of the flow inside the combustion chamber of a motored rotary engine

    Science.gov (United States)

    Shih, T. I-P.; Yang, S. L.; Schock, H. J.

    1986-01-01

    A numerical study was performed to investigate the unsteady, multidimensional flow inside the combustion chambers of an idealized, two-dimensional, rotary engine under motored conditions. The numerical study was based on the time-dependent, two-dimensional, density-weighted, ensemble-averaged conservation equations of mass, species, momentum, and total energy valid for two-component ideal gas mixtures. The ensemble-averaged conservation equations were closed by a K-epsilon model of turbulence. This K-epsilon model of turbulence was modified to account for some of the effects of compressibility, streamline curvature, low-Reynolds number, and preferential stress dissipation. Numerical solutions to the conservation equations were obtained by the highly efficient implicit-factored method of Beam and Warming. The grid system needed to obtain solutions were generated by an algebraic grid generation technique based on transfinite interpolation. Results of the numerical study are presented in graphical form illustrating the flow patterns during intake, compression, gaseous fuel injection, expansion, and exhaust.

  14. A two-dimensional numerical study of the flow inside the combustion chambers of a motored rotary engine

    Science.gov (United States)

    Shih, T. I. P.; Yang, S. L.; Schock, H. J.

    1986-01-01

    A numerical study was performed to investigate the unsteady, multidimensional flow inside the combustion chambers of an idealized, two-dimensional, rotary engine under motored conditions. The numerical study was based on the time-dependent, two-dimensional, density-weighted, ensemble-averaged conservation equations of mass, species, momentum, and total energy valid for two-component ideal gas mixtures. The ensemble-averaged conservation equations were closed by a K-epsilon model of turbulence. This K-epsilon model of turbulence was modified to account for some of the effects of compressibility, streamline curvature, low-Reynolds number, and preferential stress dissipation. Numerical solutions to the conservation equations were obtained by the highly efficient implicit-factored method of Beam and Warming. The grid system needed to obtain solutions were generated by an algebraic grid generation technique based on transfinite interpolation. Results of the numerical study are presented in graphical form illustrating the flow patterns during intake, compression, gaseous fuel injection, expansion, and exhaust.

  15. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  16. Study of (α , p) and (α , n) reactions with a Multi-Sampling Ionization Chamber

    Science.gov (United States)

    Avila, M. L.; Rehm, K. E.; Almaraz-Calderon, S.; Ayangeakaa, A. D.; Dickerson, C.; Hoffman, C. R.; Jiang, C. L.; Kay, B. P.; Lai, J.; Nusair, O.; Pardo, R. C.; Santiago-Gonzalez, D.; Talwar, R.; Ugalde, C.

    2017-07-01

    A large number of (α , p) and (α , n) reactions are known to play a fundamental role in nuclear astrophysics. This work presents a novel technique to study these reactions with the active target system MUSIC whose segmented anode allows the investigation of a large energy range of the excitation function with a single beam energy. In order to verify the method, we performed direct measurements of the previously measured reactions 17O (α , n) 20Ne, 23Na (α , p) 26Mg, and 23Na (α , n) 26Al. These reactions were investigated in inverse kinematics using 4He gas in the detector to study the excitation functions in the energy range of about 2-6 MeV in the center of mass. We found good agreement between the cross sections of the 17O (α , n) 20Ne reaction measured in this work and previous measurements. Furthermore we have successfully performed a simultaneous measurement of the 23Na (α , p) 26Mg and 23Na (α , n) 26Al reactions.

  17. Numerical Study on Turbulent Flow Inside a Channel with an Extended Chamber

    International Nuclear Information System (INIS)

    Lee, Young Tae; Lim, Hee Chang

    2010-01-01

    The paper describes a Large Eddy Simulation (LES) study of turbulent flow around a cavity. A series of three-dimensional cavities placed in a turbulent boundary layer are simulated at a Reynolds number of 1.0 x 10 5 by considering U and h, which represent the velocity at the top and the depth of the cavity, respectively. In order to obtain the appropriate solution for the filtered Navier-Stokes equation for incompressible flow, the computational mesh forms dense close to the wall of the cavity but relatively coarse away from the wall; this helps reduce computation cost and ensure rapid convergence. The Boussinesq hypothesis is employed in the subgrid-scale turbulence model. In order to determine the subgrid-scale turbulent viscosity, the Smagorinsky-Lilly SGS model is applied and the CFL number for time marching is set as 1.0. The results show the flow variations inside cavities of different sizes and shapes

  18. Chamber propagation physics for heavy ion fusion

    International Nuclear Information System (INIS)

    Callahan, D.A.

    1995-01-01

    Chamber transport is an important area of study for heavy ion fusion. Final focus and chamber-transport are high leverage areas providing opportunities to significantly decrease the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (approx-lt 0.003 torr), ballistic or nearly-ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (approx-gt.1 torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber then transporting it at small radius (∼ 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity

  19. Chamber propagation physics for heavy ion fusion

    International Nuclear Information System (INIS)

    Callahan, D.A.

    1996-01-01

    Chamber transport is a key area of study for heavy ion fusion. Final focus and chamber transport are high leverage areas providing opportunities to decrease significantly the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (below about 0.003 Torr), ballistic or nearly ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (above about 0.1 Torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber and then transporting it at small radius (about 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity. (orig.)

  20. Study of Rare Beauty Decays with ATLAS Detector at LHC and MDT Chamber Perfomances

    CERN Document Server

    Policicchio, Antonio

    2006-01-01

    The Large Hadron Collider (LHC) is a proton-proton collider that will operate at a center of mass energy of $14~TeV$ and at a maximum luminosity of $L=10^{34}cm^{-2}s^{-1}$. The LHC will reproduce interactions similar to those which existed when the universe was only $\\sim 10^{-12}s$ old, conditions which have not been achieved in any previous collider. The primary goals of the LHC project are to discover the origin of particle masses, to explain why different particles have different masses and to search for new phenomena beyond the Standard Model. Also heavy quark systems and precision measurements on Standard Model parameters will be subject of LHC physics studies. ATLAS (A Toroidal LHC ApparatuS) is one of the two LHC general purpose experiments. The guiding principle in optimizing the ATLAS experiment has been maximizing the discovery potential for New Physics such as Higgs bosons and supersymmetric particles, while keeping the capability of high precision measurements of known objects such as heavy quar...

  1. Study of fast operating readout electronics and charge interpolation technique for micro cathode strip chambers (MCSC)

    CERN Document Server

    Kashchuk, A; Sagidova, Nailia

    1998-01-01

    Study of the factors limiting the spatial resolution of the MCSC caused by nonlinearity of the cathode-charge interpolation technique has been carried out using a special test arrangement that imitates the charge distribution on the cathode strips as a real MCSC and allows high precision comparison of the coordinates determined by the charge interpolation technique with the known values. We considered a MCSC with a 0.6 mm gap between the anode and the cathode strip planes and with the strip pitch of 0.9 mm. Various charge interpolation algorithms have been tested. It was demonstrated that the systematics errors in the coordinate measurements as low as 5 microns can be achieved, after applying some simple corrections, even with rather coarse sampling, when the coordinates is determined only by 2 or 3 adjacent strips. These results have been obtained with the readout electronics specially designed for fast operation of the MCSCs with the signal peaking time of 20 ns. The equivalent noise charge ss 1600e (r.m.s....

  2. Numerical studies of the integration of a trapped vortex combustor into traditional combustion chambers

    Energy Technology Data Exchange (ETDEWEB)

    Patrignani, L.; Losurdo, M.; Bruno, C. [Sapienza Univ. de Roma, Rome (Italy)

    2010-09-15

    Exhaust emissions from furnace burners can be reduced by premixing reactants with combustion products. This paper discussed the use of a trapped vortex combustor (TVC) as a very promising technology for gas turbines. The TVC can reduce emissions and ensure that the temperature is uniform in the exhaust products, which is a key aspect for certain types of heat treatments, such as in steel rolling mills. The TVC for gas turbines is configured to mix air, fuel and hot products at turbulent scales fine enough to render the combustion mode flameless, or close to flameless. The vortex ensures a high recirculation factor between hot combustion products and reactants, and ultimately flame stability. In this study, the TVC configuration for an existing gas turbine was numerically investigated by means of RANS and LES. According to preliminary results of the fast-flameless combustion (FFC) strategy, the proposed TVC is a suitable candidate to reduce nitrogen oxide (NOx) emissions while keeping the pressure drop below 1 per cent. Both RANS and LES show that too much fuel burns along the main duct. Better fuel splitting or a different position for the injectors may enhance combustion inside the recirculation zone. Behaviour of the main vortices showed that a more accurate design of the internal shape of the combustor is needed to prevent excessive velocity fluctuation or vortex instabilities and therefore emissions. 13 refs., 9 figs.

  3. Study of the linearity of CABRI experimental ionization chambers during RIA transients

    Science.gov (United States)

    Lecerf, J.; Garnier, Y.; Hudelot, JP.; Duc, B.; Pantera, L.

    2018-01-01

    CABRI is an experimental pulse reactor operated by CEA at the Cadarache research center and funded by the French Nuclear Safety and Radioprotection Institute (IRSN). For the purpose of the CABRI International Program (CIP), operated and managed by IRSN under an OECD/NEA framework it has been refurbished since 2003 to be able to provide experiments in prototypical PWR conditions (155 bar, 300 °C) in order to study the fuel behavior under Reactivity Initiated Accident (RIA) conditions. This paper first reminds the objectives of the power commissioning tests performed on the CABRI facility. The design and location of the neutron detectors monitoring the core power are also presented. Then it focuses on the different methodologies used to calibrate the detectors and check the consistency and co-linearity of the measurements. Finally, it presents the methods used to check the linearity of the neutron detectors up to the high power levels ( 20 GW) reached during power transients. Some results obtained during the power tests campaign are also presented.

  4. Radon-daughter chamber instrumentation system reference manual

    International Nuclear Information System (INIS)

    Showalter, R.; Johnson, L.

    1985-01-01

    The radon-daughter chamber instrumentation system collects environmental data from the radon-daughter chamber. These data are then recorded on a Tandberg system tape cartridge and transmitted to the HP-1000 computer for processing. Generators which inject radon and condensation nuclei into the chamber are also included with the instrumentation system

  5. Comparison of temperature rise in the pulp chamber with different light curing units: An in-vitro study.

    Science.gov (United States)

    Rajesh Ebenezar, A V; Anilkumar, R; Indira, R; Ramachandran, S; Srinivasan, M R

    2010-07-01

    This in vitro study was designed to measure and compare the temperature rise in the pulp chamber with different light curing units. The study was done in two settings-in-vitro and in-vivo simulation. In in-vitro setting, 3mm and 6mm acrylic spacers with 4mm tip diameter thermocouple was used and six groups were formed according to the light curing source- 3 Quartz-Tungsten-Halogen (QTH) units and 3 Light-Emitting-Diode (LED) units. For the LED units, three modes of curing like pulse-cure mode, fast mode and ramp mode were used. For in-vivo simulation, 12 caries free human third molar tooth with fused root were used. K-type thermocouple with 1 mm tip diameter was used. Occlusal cavity was prepared, etched, rinsed with water and blot dried; bonding agent was applied and incremental curing of composite was done. Thermal emission for each light curing agent was noted. Temperature rise was very minimal in LED light cure units than in QTH light cure units in both the settings. Temperature rise was minimal at 6mm distance when compared to 3 mm distance. Among the various modes, fast mode produces the less temperature rise. Temperature rise in all the light curing units was well within the normal range of pulpal physiology. Temperature rise caused due to light curing units does not result in irreversible pulpal damage.

  6. Study of thermal, radiation and environmental effects on serpentine

    International Nuclear Information System (INIS)

    Raje, Naina; Kalekar, Bhupesh B.; Dubey, K.A.

    2016-01-01

    Physical and chemical properties of a material, such as particle size surface area, magnetic properties, water content, radiation and thermal stability, viscosity, porosity, are responsible for their specific applications. Serpentine is a greenish, layer structured phyllosilicate, known as magnesium hydroxy silicate. The availability of large number of hydroxyl group makes serpentine a potential candidate for nuclear shielding material. Hence present studies have been carried out to understand the stability of serpentine with the variation in thermal, radiation and environmental parameters. Serpentine samples were received from Reactor Projects Division, BARC. An accurately weighed sample was subjected to simultaneous TG - DTA - EGA measurements in air as well as inert atmosphere at the heating rate of 10 °C/min. The sample was heated from room temperature to 1000 °C with a gas flow rate of 100 mL/min in Netzsch thermal analyzer (Model STA409 PC LUXX) connected to Bruker FTIR system (Model - Tensor27) via a 1m long capillary. The sample was subjected to gamma radiation in the range of 10 - 100 kGy using 60 Co gamma source in gamma chamber and was subjected to TG measurements to understand the effect of radiation on the thermal stability of serpentine and the results are being discussed here

  7. Experimental and numerical study of premixed hydrogen/air flame propagating in a combustion chamber.

    Science.gov (United States)

    Xiao, Huahua; Sun, Jinhua; Chen, Peng

    2014-03-15

    An experimental and numerical study of dynamics of premixed hydrogen/air flame in a closed explosion vessel is described. High-speed shlieren cinematography and pressure recording are used to elucidate the dynamics of the combustion process in the experiment. A dynamically thickened flame model associated with a detailed reaction mechanism is employed in the numerical simulation to examine the flame-flow interaction and effect of wall friction on the flame dynamics. The shlieren photographs show that the flame develops into a distorted tulip shape after a well-pronounced classical tulip front has been formed. The experimental results reveal that the distorted tulip flame disappears with the primary tulip cusp and the distortions merging into each other, and then a classical tulip is repeated. The combustion dynamics is reasonably reproduced in the numerical simulations, including the variations in flame shape and position, pressure build-up and periodically oscillating behavior. It is found that both the tulip and distorted tulip flames can be created in the simulation with free-slip boundary condition at the walls of the vessel and behave in a manner quite close to that in the experiments. This means that the wall friction could be unimportant for the tulip and distorted tulip formation although the boundary layer formed along the sidewalls has an influence to a certain extent on the flame behavior near the sidewalls. The distorted tulip flame is also observed to be produced in the absence of vortex flow in the numerical simulations. The TF model with a detailed chemical scheme is reliable for investigating the dynamics of distorted tulip flame propagation and its underlying mechanism. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Environmental injustice: case studies from the South

    International Nuclear Information System (INIS)

    Cifuentes, Enrique; Frumkin, Howard

    2007-01-01

    We selected three case studies to illustrate environmental injustice issues in the South. These examples relate to migrant agricultural workers, the maquiladora industry and artisanal mining, while reviewing some of the major mechanisms involved, e.g. multinational corporations, the development of free trade zones, multilateral free trade agreements and the export of hazards. A series of strategies are discussed in order to address environmental injustice and health disparities that exist on a global scale. Some of the recommendations involve policy initiatives; others, such as research and mentorship, fall within the traditional domain of public health practice. In this paper, special attention is given to concerned environmental and occupational health professionals using evidence-based data for advocacy. For lasting changes to be made, however, stronger institutions and legislation are required. Those who have the 'right to know' about environmental injustice issues include communities of concern, workers' representatives and lawyers. Government officials and company officials may eventually work on the basis of conflict resolution, compensation and remediation, to quote some examples. Systematic approaches to protect both the environment and public health must be updated

  9. Environmental injustice: case studies from the South

    Science.gov (United States)

    Cifuentes, Enrique; Frumkin, Howard

    2007-10-01

    We selected three case studies to illustrate environmental injustice issues in the South. These examples relate to migrant agricultural workers, the maquiladora industry and artisanal mining, while reviewing some of the major mechanisms involved, e.g. multinational corporations, the development of free trade zones, multilateral free trade agreements and the export of hazards. A series of strategies are discussed in order to address environmental injustice and health disparities that exist on a global scale. Some of the recommendations involve policy initiatives; others, such as research and mentorship, fall within the traditional domain of public health practice. In this paper, special attention is given to concerned environmental and occupational health professionals using evidence-based data for advocacy. For lasting changes to be made, however, stronger institutions and legislation are required. Those who have the 'right to know' about environmental injustice issues include communities of concern, workers' representatives and lawyers. Government officials and company officials may eventually work on the basis of conflict resolution, compensation and remediation, to quote some examples. Systematic approaches to protect both the environment and public health must be updated.

  10. Double chamber ion source

    International Nuclear Information System (INIS)

    Uman, M.F.; Winnard, J.R.; Winters, H.F.

    1978-01-01

    The ion source is comprised of two discharge chambers one of which is provided with a filament and an aperture leading into the other chamber which in turn has an extraction orifice. A low voltage arc discharge is operated in an inert gas atmosphere in the filament chamber while an arc of higher voltage is operated in the second ionization chamber which contains a vapor which will give the desired dopant ion species. The entire source is immersed in an axial magnetic field parallel to a line connecting the filament, the aperture between the two chambers and the extraction orifice. (author)

  11. Stability of Streamer Chamber

    Science.gov (United States)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi

    1982-08-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result.

  12. Stability of streamer chamber

    International Nuclear Information System (INIS)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi.

    1982-01-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result. (author)

  13. Environmental Studies at the Guiana Space Centre

    Science.gov (United States)

    Richard, Sandrine

    2013-09-01

    The Environmental Commitment of the French Space Agency at the Guiana Space Centre (CNES / CSG) specifies that the environmental protection is a major stake. Consequently, CNES participates in numerous space programs that contribute significantly to a better knowledge, management and protection of our environment at a global scale.The studies and researches that are done at CNES / CSG meet several objectives:* Assessment of safety and environmental effects and risk related to the effects overflowing due to a pollution caused by ground and flight activities* Improvement of the studies related to the knowledge of the environment (flora and fauna monitoring).* Risk assessment and management which may affect the safety of people , property, and protection of public health and environment * Verification of the compliance of the results of impact studies of launch vehicle in flight phase provided by the launch operator (Technical Regulation) with the French Safety Operational Acts.In this note, study and research programs are presented. They allow a better knowledge of the surrounding environment and of impacts caused by the industrial activities done in Guiana Space Center.

  14. Reactor oscillator project - Theoretical study; operation problems; choice of the ionization chamber; Projekat reaktorskog oscilatora - Teorijska razmatranja; Problematika rada, Izbor jonizacione komore

    Energy Technology Data Exchange (ETDEWEB)

    Lolic, B; Markovic, V [Institute of Nuclear Sciences Boris Kidric, Laboratorija za fiziku reaktora, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    Theoretical study of the reactor operator covers methods of the danger coefficient and the method based on measuring the phase angle. Operation with the reactor oscillator describes measurement of the cross section and resonance integral, measurement of the fissionable materials properties, measurement of impurities in the graphite sample. A separate chapter is devoted to the choice of the appropriate ionization chamber.

  15. Studies of tungsten erosion at the inner and outer main chamber wall of the ASDEX Upgrade tokamak

    Science.gov (United States)

    Tabasso, A.; Maier, H.; Roth, J.; Krieger, K.; ASDEX Upgrade Team

    2001-03-01

    A critical issue for the choice of main chamber first wall materials in future fusion devices such as ITER is the erosion rate due to bombardment by charge-exchange (CX) neutrals. Due to the relatively small flux density of impacting particles, respective measurements are only possible using long term samples (LTS) exposed for a full experimental campaign. In ASDEX Upgrade, CX erosion has been studied extensively for tungsten on the inner heat shield by placing four W coated tiles at different poloidal positions in one toroidal sector. During the same campaign, several LTS were placed at different poloidal and toroidal positions of the outer wall. 13C and Cu coated graphite probes were also used in order to test and compare W low and medium Z alternatives. The erosion results from the probes are compared with the calculated erosion [W. Eckstein, C. Garcia-Rosales, J. Roth, W. Ottenberger IPP Report, IPP 9/82]; [H. Verbeek, J. Stober, D. Coster, W. Eckstein, R. Schneider Nucl. Fus. 38 (1998) 12] and a figure of merit (F. of M.) between several materials is proposed which also takes into account the plasma isotope effect in CX erosion.

  16. Studies of tungsten erosion at the inner and outer main chamber wall of the ASDEX Upgrade tokamak

    International Nuclear Information System (INIS)

    Tabasso, A.; Maier, H.; Roth, J.; Krieger, K.

    2001-01-01

    A critical issue for the choice of main chamber first wall materials in future fusion devices such as ITER is the erosion rate due to bombardment by charge-exchange (CX) neutrals. Due to the relatively small flux density of impacting particles, respective measurements are only possible using long term samples (LTS) exposed for a full experimental campaign. In ASDEX Upgrade, CX erosion has been studied extensively for tungsten on the inner heat shield by placing four W coated tiles at different poloidal positions in one toroidal sector. During the same campaign, several LTS were placed at different poloidal and toroidal positions of the outer wall. 13 C and Cu coated graphite probes were also used in order to test and compare W low and medium Z alternatives. The erosion results from the probes are compared with the calculated erosion [W. Eckstein, C. Garcia-Rosales, J. Roth, W. Ottenberger IPP Report, IPP 9/82]; [H. Verbeek, J. Stober, D. Coster, W. Eckstein, R. Schneider Nucl. Fus. 38 (1998) 12] and a figure of merit (F. of M.) between several materials is proposed which also takes into account the plasma isotope effect in CX erosion

  17. Studies of ageing effects of Small-Strip Thin Gap Chambers for the Muon Spectrometer Upgrade of the ATLAS Experiment

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00425540; The ATLAS collaboration

    2016-01-01

    The instantaneous luminosity of the Large Hadron Collider at CERN will be increased by up to seven times its design value by undergoing an extensive upgrade program over the coming decade. The largest upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs), to be installed during the LHC long shutdown in 2019-2020. Small-Strip Thin Gap Chambers (sTGC) detectors are one chosen technology to provide fast trigger and high precision muon tracking under the high luminosity LHC conditions. The basic sTGC structure consists of a grid of gold-plated tungsten wires sandwiched between two resistive cathode planes at a small distance from the wire plane. We study ageing effects of sTGC detectors with a gas mixture of 55\\% of CO$_{2}$ and 45\\% of n-pentane. A sTGC detector was irradiated with beta-rays from a 10~mCi~$^{90}$Sr source. Three different gas flow rates were tested. We observed no deterioration on pulse height o...

  18. Studies of ageing effects of Small-Strip Thin Gap Chambers for the Muon Spectrometer Upgrade of the ATLAS Experiment

    CERN Document Server

    Gignac, Matthew; The ATLAS collaboration

    2016-01-01

    The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the design value by undergoing an extensive upgrade program over the coming decade. The largest upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs), to be installed during the LHC long shutdown in 2019/20. Small-Strip Thin Gap Chambers (sTGC) detectors are one chosen technology to provide fast trigger and high precision muon tracking under the high luminosity LHC conditions. The basic sTGC structure consists of a grid of gold-plated tungsten wires sandwiched between two resistive cathode planes at a small distance from the wire plane. We study ageing effects of sTGC detectors with a gas mixture of 55% of CO_2 and 45% of n-pentane. A sTGC detector was irradiated with beta-rays from a Sr-90 source. Three different gas flow rates were tested. We observed no deterioration on pulse height of...

  19. Study on the dose response characteristics of a scanning liquid ion-chamber electronic portal imaging device

    CERN Document Server

    Ma Shao Gang; Song Yi Xin

    2002-01-01

    Objective: To study the dose response characteristics and the influence factors such as gantry angle, field size and acquisition mode on the dosimetric response curves, when using a scanning liquid ion-chamber electronic portal imaging device (EPID) for dose verification. Methods: All experiments were carried out on a Varian 600 C/D accelerator (6 MV X-ray) equipped with a Varian PortalVision sup T sup M MK2 type EPID. To obtain the dose response curve, the relationship between the incident radiation intensity to the detector and the pixel value output from the EPID were established. Firstly, the different dose rates of 6 MV X-rays were obtained by varying SSD. Secondly, three digital portal images were acquired for each dose rate using the EPID and averaged to avoid the influence of the dose rate fluctuations of the accelerator. The pixel values of all images were read using self-designed image analysis software, and and average for a region consisting of 11 x 11 pixels around the center was taken as the res...

  20. High-repetition-rate hydrogen chamber: Preliminary studies; Chambre a hydrogene a haut taux de repetition: Etudes preliminaires

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1967-01-01

    This report is a conclusion to the tests realised with an experimental bubbles chamber in view to study the possibilities to increase the repetition rate. The more important parameters (the evolution of the bubbles, the expansion system) are considered in a theoretical way. Then the hardware is described. To end, experimental results are compared with the first evaluations. The calculations and the experimentation are against an oscillation system for the expansion. A system with a locking is to he considered. (authors) [French] Ce rapport est une conclusion aux essais realises avec une chambre a bulles experimentale en vue d'etudier les possibilites d'accroitre les taux de repetition. Les parametres les plus importants (evolution des bulles, mecanique de la detente) sont etudies par voie theorique. Puis l'appareillage est decrit. Enfin, les resultats experimentaux sont compares aux evaluations donnees au debut. Ces calculs et cette experimentation ne sont pas en faveur d'un systeme oscillant pour la detente et il faut envisager un systeme avec verrouillage. (auteurs)

  1. An Experimental Study on the Macroscopic Spray Characteristics of Biodiesel and Diesel in a Constant Volume Chamber

    Directory of Open Access Journals (Sweden)

    Hongzhan Xie

    2015-06-01

    Full Text Available The objective of this study was to investigate the macroscopic spray characteristics of different 0%–100% blends of biodiesel derived from drainage oil and diesel (BD0, BD20, BD50, BD80, BD100, such as spray tip penetration, average tip velocity at penetration, spray angle, average spray angle, spray evolution process, spray area and spray volume under different injection pressures (60, 70, 80, 90, 100 MPa and ambient pressures (0.1, 0.3, 0.5, 0.7, 0.9 MPa using a common rail system equipped with a constant volume chamber. The characteristic data was extracted from spray images grabbed by a high speed visualization system. The results showed that the ambient pressure and injection pressure had significant effects on the spray characteristics. As the ambient pressure increased, the spray angle increased, while the spray tip penetration and the peak of average tip velocity decreased. As the injection pressure increased, the spray tip penetration, spray angle, spray area and spray volume increased. The increasing blend ratio of biodiesel brought about a shorter spray tip penetration and a smaller spray angle compared with those of diesel. This is due to the comparatively higher viscosity and surface tension of biodiesel, which enhanced the friction effect between fuel and the injector nozzle surface and inhibited the breakup of the liquid jet.

  2. Course Descriptions in Environmental Studies Part Two: Interdisciplinary Courses.

    Science.gov (United States)

    Dunlap, Riley; And Others

    1984-01-01

    Presents descriptions (syllabi, outlines, goals) of interdisciplinary environmental studies courses. Topic areas of these courses include: environmental sociology; human ecology (politics, institutions, and the environment); humans and the environment in historical perspective; environmental management; humans, hazards, and disasters; and other…

  3. Course Descriptions in Environmental Studies Part One: Historical Courses.

    Science.gov (United States)

    Hughes, Donald; And Others

    1984-01-01

    Presents descriptions (syllabi, outlines, goals) of selected environmental studies courses which approach the discipline from an historical and humanistic perspective. Areas explored in the courses include human ecology, American environmental history, environmental politics, and others. (JN)

  4. Quantifying Contaminant Mass for the Feasibility Study of the DuPont Chambers Works FUSRAP Site - 13510

    Energy Technology Data Exchange (ETDEWEB)

    Young, Carl; Rahman, Mahmudur; Johnson, Ann; Owe, Stephan [Cabrera Services Inc., 1106 N. Charles St., Ste. 300, Baltimore, MD 21201 (United States)

    2013-07-01

    The U.S. Army Corps of Engineers (USACE) - Philadelphia District is conducting an environmental restoration at the DuPont Chambers Works in Deepwater, New Jersey under the Formerly Utilized Sites Remedial Action Program (FUSRAP). Discrete locations are contaminated with natural uranium, thorium-230 and radium-226. The USACE is proposing a preferred remedial alternative consisting of excavation and offsite disposal to address soil contamination followed by monitored natural attenuation to address residual groundwater contamination. Methods were developed to quantify the error associated with contaminant volume estimates and use mass balance calculations of the uranium plume to estimate the removal efficiency of the proposed alternative. During the remedial investigation, the USACE collected approximately 500 soil samples at various depths. As the first step of contaminant mass estimation, soil analytical data was segmented into several depth intervals. Second, using contouring software, analytical data for each depth interval was contoured to determine lateral extent of contamination. Six different contouring algorithms were used to generate alternative interpretations of the lateral extent of the soil contamination. Finally, geographical information system software was used to produce a three dimensional model in order to present both lateral and vertical extent of the soil contamination and to estimate the volume of impacted soil for each depth interval. The average soil volume from all six contouring methods was used to determine the estimated volume of impacted soil. This method also allowed an estimate of a standard deviation of the waste volume estimate. It was determined that the margin of error for the method was plus or minus 17% of the waste volume, which is within the acceptable construction contingency for cost estimation. USACE collected approximately 190 groundwater samples from 40 monitor wells. It is expected that excavation and disposal of

  5. A Study on improvement of comprehensive environmental management system - activation of liberalized environmental management

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hweu Sung; Kang, Chul Goo [Korea Environment Institute, Seoul (Korea)

    1998-12-01

    As a part of improvement on a comprehensive environmental management system, this study was attempted to find an activating policy for a liberalized environmental management. This study provided an activation plan of reasonable environmental regulation reform and liberalized environmental management through the analysis of foreign examples and domestic situation. Furthermore, it analyzed an institutional mechanism for a smooth operation of liberalized environmental management. 68 refs., 5 figs., 51 tabs.

  6. Analytical study on water hammer pressure in pressurized conduits with a throttled surge chamber for slow closure

    Directory of Open Access Journals (Sweden)

    Yong-liang Zhang

    2010-06-01

    Full Text Available This paper presents an analytical investigation of water hammer in a hydraulic pressurized pipe system with a throttled surge chamber located at the junction between a tunnel and a penstock, and a valve positioned at the downstream end of the penstock. Analytical formulas of maximum water hammer pressures at the downstream end of the tunnel and the valve were derived for a system subjected to linear and slow valve closure. The analytical results were then compared with numerical ones obtained using the method of characteristics. There is agreement between them. The formulas can be applied to estimating water hammer pressure at the valve and transmission of water hammer pressure through the surge chamber at the junction for a hydraulic pipe system with a surge chamber.

  7. A study to assess the long-term stability of the ionization chamber reference system in the LNMRI

    Science.gov (United States)

    Trindade Filho, O. L.; Conceição, D. A.; da Silva, C. J.; Delgado, J. U.; de Oliveira, A. E.; Iwahara, A.; Tauhata, L.

    2018-03-01

    Ionization chambers are used as secondary standard in order to maintain the calibration factors of radionuclides in the activity measurements in metrology laboratories. Used as radionuclide calibrator in nuclear medicine clinics to control dose in patients, its long-term performance is not evaluated systematically. A methodology for long-term evaluation for its stability is monitored and checked. Historical data produced monthly of 2012 until 2017, by an ionization chamber, electrometer and 226Ra, were analyzed via control chart, aiming to follow the long-term performance. Monitoring systematic errors were consistent within the limits of control, demonstrating the quality of measurements in compliance with ISO17025.

  8. A study to assess the long-term stability of the ionization chamber reference system in the LNMRI

    Energy Technology Data Exchange (ETDEWEB)

    Filho, Octavio L.T.; Conceição, Dayana A. da; Silva, Carlos J. da; Delgado, José U.; Oliveira, Antônio E. de; Iwahara, Akira; Tauhata, Luiz, E-mail: octavio@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Ionization chambers are used as secondary standard in order to maintain the calibration factors of radionuclides in the activity measurements in metrology laboratories. Used as radionuclide calibrator in nuclear medicine clinics to control dose in patients, its long-term performance is not evaluated systematically. A methodology for long-term evaluation for its stability is monitored and checked. Historical data were analyzed via control chart, produced between 2012-2017 by an ionization chamber, electrometer and {sup 226}Ra, aiming to follow the long-term performance. The results for monitoring systematic errors were consistent within the limits of control, demonstrating the quality of measurements in compliance with ISO17025. (author)

  9. Environmental and Social Impact Study: Final Report

    International Nuclear Information System (INIS)

    2011-04-01

    The tsetse control project (commonly known as tsetse flies) is an initiative of the Directorate of Livestock (project coordinating institution) and the ISRA (Senegalese Agricultural Research Institute) Accompaniment and diagnosis of the project. It is part of the cooperation between Senegal and the International Atomic Energy Agency (IAEA).The method of control that will be applied is the technique of sterile males.This technique of sterile males, however, is coupled with the use of deltamethrin (D6), a neurotoxic chemical (in adult insects) that is fast and fairly rapidly biodegradable in the environment.This study is carried out with the aim of taking good account of the environmental impacts of the various activities envisaged by the project. Its objective is to assess the biophysical, social and economic impacts of the project and to propose measures to mitigate or compensate for negative impacts and to reinforce positive impacts within the framework of an Environmental Management Plan and (ESMP). It also presents an environmental and social monitoring and monitoring plan to assess the effectiveness of the proposed mitigation measures.

  10. The vacuum chamber in the interaction region of particle colliders a historical study and developments implementations in the LHCb experiment at CERN

    CERN Document Server

    Knaster, J R; Gamez-Mejias, L

    2004-01-01

    The history of particle colliders begins in the early 60's when an idea previously patented by R. Wideroe in 1953 is constructed. The design of the vacuum chamber in their experimental area became essential as it was the rst physical barrier that the particles to be detected needed to traverse. The interaction of the products of the collisions with the vacuum chamber structural materials, hindered the identification of the significative events. This Thesis analyses the historical evolution of the experimental vacuum chambers and summarizes the technical criteria that are to be fulfilled. The Large Hadron Collider (LHC) presently under construction at CERN is the last generation of particle colliders. Four big experiments will be in operation (ATLAS, CMS, ALICE and LHCb) in the LHC with diferent physics objectives. In particular, LHCb will be devoted to the study of CP violation and the design of its vacuum chamber is the scope of this Thesis. Physics simulations with an initial design consisting of a conical ...

  11. Ferrets’ (Mustela putorius furo) enrichment priorities and preferences as determined in a seven-chamber consumer demand study

    NARCIS (Netherlands)

    Reijgwart, Marsinah Lusanne; Vinke, C.M.; Hendriksen, C.F.M.; Van Der Meer, Miriam; Schoemaker, N.J.; van Zeeland, Y.R.A.

    Knowledge of species-specific motivation and preferences for enrichment options is necessary to put in place an appropriate enrichment plan. This knowledge is currently lacking for ferrets. Therefore, seven female ferrets were consecutively housed in a seven-chamber closed economy consumer demand

  12. Algorithm for study on the stressed-strained state of thermonuclear device vacuum chambers under dynamic loads

    International Nuclear Information System (INIS)

    Zhuravleva, A.M.; Litvinov, V.B.

    1982-01-01

    The problem of dynamic analysis of stressed-strained state of vacuum chambers is vital for large thermonuclear devices during the stall of the plasma-filament apd other tpansitional operation regimes when loading for a chamber are nonstationary. To plot a mathematical model the design of the vacuum chamber is discreted on the basis of the method of final elements. To approximate vacuum shell, a plate triangular element with 3 joint points and 5 parameters in the joint is used. It is obtained due to the unity of the bemded element and the element for the flat problem. To investigate nonstationary oscillations of vacuum chambers discreted on the basis of the method of final elements, it is suggested to use the numeric conversion of the Japlace transformation. On the basis of the algorithm suggested a program of numerical function conversion is developed. Test calculations have shown a good stability of the algorithm when selecting the values of transformation parameter in the range of lower intrinsic system frequencies. The advantage of the above method is in the fact that the time-structure shift function is found instantly in the form of the series for the whole time interval and does not require temporary steps, which bring about large expenses of counting time and error accumulation

  13. Study on the stability of waterpower-speed control system for hydropower station with air cushion surge chamber

    International Nuclear Information System (INIS)

    Guo, W C; Yang, J D; Chen, J P; Teng, Y

    2014-01-01

    According to the fact that the effects of penstock, unit and governor on stability of water level fluctuation for hydropower station with air cushion surge chamber are neglected in previous researches, in this paper, Thoma assumption is broken through, the complete mathematical model of waterpower-speed control system for hydropower station with air cushion surge chamber is established, and the comprehensive transfer function and linear homogeneous differential equation that characterize the dynamic characteristics of system are derived. The stability domain that characterizes the good or bad of stability quantitatively is drawn by using the stability conditions. The effects of the fluid inertia in water diversion system, the air cushion surge chamber parameters, hydraulic turbine characteristics, generator characteristics, and regulation modes of governor on the stability of waterpower-speed control system are analyzed through stability domain. The main conclusions are as follows: The fluid inertia in water diversion system and hydraulic turbine characteristics have unfavorable effects on the system while generator characteristics have favorable effect. The stability keeps getting better with the increase of chamber height and basal area and the decrease of air pressure and air polytropic exponent. The stability of power regulation mode is obviously better than that of frequency regulation mode

  14. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  15. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  16. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  17. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  18. The Interplay among Environmental Attitudes, Pro-Environmental Behavior, Social Identity, and Pro-Environmental Institutional Climate. A Longitudinal Study

    Science.gov (United States)

    Prati, Gabriele; Albanesi, Cinzia; Pietrantoni, Luca

    2017-01-01

    By using a panel design in a sample of 298 undergraduate/master students at an Italian public university, the present study aimed to test longitudinally the interplay among environmental attitudes, pro-environmental behavior, social identity, and pro-environmental institutional climate. The relationships were tested with cross-lagged analysis…

  19. Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

    Science.gov (United States)

    Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi

    2014-08-01

    To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Large area gridded ionisation chamber and electrostatic precipitator and their application to low-level alpha-spectrometry of environmental air samples

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1977-01-01

    A high-resolution, parallel plate Frisch grid ionization chamber with an efficient area of 3000 cm 2 , and a large area electrostatic precipitator were developed and applied to direct alpha spectrometry of air dust. Using an argon-methane mixture (P-10 gas) at atmospheric pressure the resolution of the detector system is 22 keV FWHM at 5 MeV. After sampling for one week and decay of short-lived natural activity, the sensitivity of the procedure for long-lived alpha emitters is about 0.1 fCi/m 3 taking 3 Σσ of background as the detection limit with 1000 min counting time. (author)

  1. Gas microstrip chambers

    International Nuclear Information System (INIS)

    McIntyre, P.M.; Barasch, E.F.; Bowcock, T.J.V.; Demroff, H.P.; Elliott, S.M.; Howe, M.R.; Lee, B.; Mazumdar, T.K.; Pang, Y.; Smith, D.D.; Wahl, J.; Wu, Y.; Yue, W.K.; Gaedke, R.M.; Vanstraelen, G.

    1992-01-01

    The gas microstrip chamber has been developed from concept to experimental system during the past three years. A pattern of anode and grid lines are microfabricated onto a dielectric substrate and configured as a high-resolution MWPC. Four recent developments are described: Suitable plastic substrates and lithography techniques for large-area chambers; non-planar silicon-based chambers for 20 μm resolution; integrated on-board synchronous front-end electronics and data buffering; and a porous silicon active cathode for enhanced efficiency and time response. The microstrip chamber appears to be a promising technology for applications in microvertex, tracking spectrometer, muon spectrometer, and transition radiation detection. (orig.)

  2. Study on a drift chamber for high energy experiments; Estudos sobre uma camara de arrasto para um experimento de altas energias

    Energy Technology Data Exchange (ETDEWEB)

    Puget, Maria Augusta Constante

    1993-12-31

    This work deals with the studies of a multiwire gaseous detector operating as a drift chamber, which will be part of the SELEX spectrometer of the experiment Fermilab E781. A prototype was designed to be built and tested at IFUSP. Results are shown of the analysis of data taken with another similar detector whose construction and test were done at Fermilab, with the aim of studying its characterization and performance. (author) 35 refs., 54 figs., 17 tabs.

  3. Study on a drift chamber for high energy experiments; Estudos sobre uma camara de arrasto para um experimento de altas energias

    Energy Technology Data Exchange (ETDEWEB)

    Puget, Maria Augusta Constante

    1994-12-31

    This work deals with the studies of a multiwire gaseous detector operating as a drift chamber, which will be part of the SELEX spectrometer of the experiment Fermilab E781. A prototype was designed to be built and tested at IFUSP. Results are shown of the analysis of data taken with another similar detector whose construction and test were done at Fermilab, with the aim of studying its characterization and performance. (author) 35 refs., 54 figs., 17 tabs.

  4. The Mark III vertex chamber

    International Nuclear Information System (INIS)

    Adler, J.; Bolton, T.; Bunnell, K.

    1987-07-01

    The design and construction of the new Mark III vertex chamber is described. Initial tests with cosmic rays prove the ability of track reconstruction and yield triplet resolutions below 50 μm at 3 atm using argon/ethane (50:50). Also performed are studies using a prototype of a pressurized wire vertex chamber with 8 mm diameter straw geometry. Spatial resolution of 35mm was obtained using dimethyl ether (DME) at 1 atm and 30 μm using argon/ethane (50/50 mixture) at 4 atm. Preliminary studies indicate the DME to adversely affect such materials as aluminized Mylar and Delrin

  5. Study of a particle detector with very high spatial precision (drift chambers), and analysis of the physical phenomena governing the operation of this detector

    International Nuclear Information System (INIS)

    Schultz, Guy.

    1976-01-01

    The physical principles of drift chambers are studied and various measurements which can be performed with these chambers are described. The laws governing the passage of particles through matter are first reviewed and different transport coefficients, (velocity, scattering coefficient, characteristic energy ...) of the electrons under the influence of an electric field for different gases (argon, CO 2 , isobutane, methane, methylal) are studied. The theoretical predictions are then compared with the experimental results. The different amplification processes in the gas and the space charge effect of the positive ions on electron multiplication for large particle fluxes are also studied as well as the mobility of positive ions in different gases. After these results, the operating characteristics (efficiency, linearity of the space-time ratio, spatial resolution), with and without an external magnetic field are determined [fr

  6. Drift chamber tracking with neural networks

    International Nuclear Information System (INIS)

    Lindsey, C.S.; Denby, B.; Haggerty, H.

    1992-10-01

    We discuss drift chamber tracking with a commercial log VLSI neural network chip. Voltages proportional to the drift times in a 4-layer drift chamber were presented to the Intel ETANN chip. The network was trained to provide the intercept and slope of straight tracks traversing the chamber. The outputs were recorded and later compared off line to conventional track fits. Two types of network architectures were studied. Applications of neural network tracking to high energy physics detector triggers is discussed

  7. An electrodeless drift chamber

    International Nuclear Information System (INIS)

    Allison, J.; Barlow, R.J.; Bowdery, C.K.; Duerdoth, I.; Rowe, P.G.

    1982-01-01

    We describe a chamber in which the drift field is controlled by the deposition of electrostatic charge on an insulating surface. The chamber operates with good efficiency and precision for observed drift distances of up to 45 cm, promises to be extremely robust and adaptable and offers a very cheap way of making particle detectors. (orig.)

  8. High resolution drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1985-07-01

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  9. Plastic flashtube chambers

    International Nuclear Information System (INIS)

    Frisken, W.R.

    1977-01-01

    A brief discussion is given of the use and operation of plastic flashtube chambers. Gas leaks, electric pulsing, the glow discharge, and readout methods are considered. Three distinct problems with high rate applications deal with resolving time, dead time, and polarization/neutralization of the chamber

  10. BEBC bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  11. The Mobile Chamber

    Science.gov (United States)

    Scharfstein, Gregory; Cox, Russell

    2012-01-01

    A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

  12. DELPHI time projection chamber

    CERN Multimedia

    1989-01-01

    The time projection chamber is inserted inside the central detector of the DELPHI experiment. Gas is ionised in the chamber as a charged particle passes through, producing an electric signal from which the path of the particle can be found. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  13. In Vitro Study of Temperature Changes in Pulp Chamber During Root Planing Procedure Using Er:YAG Laser.

    Science.gov (United States)

    Yaneva, Blagovesta K; Zagorchev, Plamen I; Firkova, Elena I; Glavinkov, Ivan T

    2016-09-01

    To assess temperature changes at specified time intervals during Er:YAG laser scaling and root planing of surfaces with dental calculus. Fifteen single-rooted teeth with advanced periodontal disease were extracted and fixed in a cylinder thermostat filled with distilled water at constant temperature (35.5°C). A specially designed thermal probe (type K thermocouple) accurate to ±0.1°C over the range from 20°C to 80°C was fitted into the pulp chamber of tooth sample. Scaling and root planing of the mesial and distal root surfaces was performed using an Er:YAG laser (Lite Touch, Syneron Dental, Israel) with a wavelength of 2940 nm, provided with a chisel tip, and at the following settings: output energy 100 mJ and 50 Hz, duration of irradiation - 40 sec, the tip in contact mode oblique to the root surface at an angle of approximately 10-15 degrees and water spray level 5-6. The temperature inside the pulp chamber was measured every 10 sec. The temperature in the pulp chamber taken every 10 seconds and compared with the temperature of 35.5°C at baseline decreased by 1.6°C, 2.4°C, 2.5°C, and 2.5°C for the first, second, third and fourth measurement, respectively. These changes did not reach statistical significance. The Er:YAG laser does not increase the temperature inside the pulp chamber. The assessed changes do not depend on the duration of irradiation which was kept within 40 seconds. Therefore, this treatment modality causes no thermal damage to the pulp under the above defined conditions and can be considered safe.

  14. Measurements of ion mobility and GEM discharge studies for the upgrade of the ALICE time projection chamber

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00507268

    2018-02-20

    ALICE is one of the four experiments at the Large Hadron Collider (LHC). The quark-gluon plasma, which is predominantly produced in lead-lead collisions at LHC, is of particular interest for ALICE. After the long shut-down 2 (2019-2021) the LHC will provide lead-lead collisions at an increased interaction rate of 50 kHz. In order to examine every event at this interaction rate the ALICE Time Projection Chamber (TPC) needs to be upgraded. The TPC’s ReadOut Chambers (ROCs) are currently multi-wire proportional chambers. To prevent space charge build-up of slow ions, drifting from the ROCs into the TPC, a gating grid is used. The corresponding closure time imposes a dead time on the TPC read out, which prohibits data taking at a readout rate higher than 3 kHz. New ROCs have therefore been designed, relying on stacks of Gas Electron Multiplier (GEM) foils for the gas amplification, allowing for continuous readout. With the new ROCs, a certain fraction of ions will be drifting at all time into the TPC. Knowing t...

  15. Laser-filament-induced snow formation in a subsaturated zone in a cloud chamber: experimental and theoretical study.

    Science.gov (United States)

    Ju, Jingjing; Sun, Haiyi; Sridharan, Aravindan; Wang, Tie-Jun; Wang, Cheng; Liu, Jiansheng; Li, Ruxin; Xu, Zhizhan; Chin, See Leang

    2013-12-01

    1 kHz, 2 mJ, 45 fs, 800 nm laser pulses were fired into a laboratory diffusion cloud chamber through a subsaturated zone (relative humidity ∼73%, T ∼ 4.3 °C). After 60 min of laser irradiation, an oval-shaped snow pile was observed right below the filament center and weighed ∼12.0 mg. The air current velocity at the edge of the vortices was estimated to be ∼16.5 cm/s. Scattering scenes recorded from the side show that filament-induced turbulence were formed inside the cloud chamber with two vortices below the filament. Two-dimensional simulations of the air flow motion in two cross sections of the cloud chamber confirm that the turbulent vortices exist below the filament. Based upon this simulation, we deduce that the vortices indeed have a three-dimensional elliptical shape. Hence, we propose that inside vortices where the humidity was supersaturated or saturated the condensation nuclei, namely, HNO(3), N(2)(+), O(2)(+) and other aerosols and impurities, were activated and grew in size. Large-sized particles would eventually be spun out along the fast moving direction towards the cold plate and formed an oval-shaped snow pile at the end.

  16. Preliminary study of the primary nozzle position of a supersonic air ejector with a constant-area mixing chamber

    Directory of Open Access Journals (Sweden)

    Kracik Jan

    2017-01-01

    Full Text Available This work aims at investigating the primary nozzle position in a proposed supersonic air ejector device. The ejector is primarily made up of a supersonic primary nozzle, which is located in the axis of the ejector, a suction chamber or secondary stream inlet, a mixing chamber and a diffuser. The ejector design allows to translate the primary nozzle in the axis direction and fix it in a chosen distance from the beginning of the mixing chamber and hence influence the secondary mass flow rate. In a limit case, it is possible to set the nozzle to such a position where no secondary flow occurs. If we ignore the case where no secondary flow occurs, five different nozzle distances have been investigated in this paper. Some cases seem to be alike and there are no significant dissimilarities between them. Courses of relative back-pressure ratio are carried out against the entrainment ratio and transition between on-design and off-design regimes is determined. Measurements of the mixed flow based on the standard ISO 5167 are performed by means of orifice plate method. In addition, a comparison between experiments and simulations performed by Ansys Fluent software is presented in order to indicate further improvements to the numerical model.

  17. Study of cavity effect in micro-Pirani gauge chamber with improved sensitivity for high vacuum regime

    Directory of Open Access Journals (Sweden)

    Guohe Zhang

    2018-05-01

    Full Text Available Ultra-low pressure application of Pirani gauge needs significant improvement of sensitivity and expansion of measureable low pressure limit. However, the performance of Pirani gauge in high vacuum regime remains critical concerns since gaseous thermal conduction with high percentage is essential requirement. In this work, the heat transfer mechanism of micro-Pirani gauge packaged in a non-hermetic chamber was investigated and analyzed compared with the one before wafer-level packaging. The cavity effect, extremely important for the efficient detection of low pressure, was numerically and experimentally analyzed considering the influence of the pressure, the temperature and the effective heat transfer area in micro-Pirani gauge chamber. The thermal conduction model is validated by experiment data of MEMS Pirani gauges with and without capping. It is found that nature gaseous convection in chamber, determined by the Rayleigh number, should be taken into consideration. The experiment and model calculated results show that thermal resistance increases in the molecule regime, and further increases after capping due to the suppression of gaseous convection. The gaseous thermal conduction accounts for an increasing percentage of thermal conduction at low pressure while little changes at high pressure after capping because of the existence of cavity effect improving the sensitivity of cavity-effect-influenced Pirani gauge for high vacuum regime.

  18. Venturi vacuum systems for hypobaric chamber operations.

    Science.gov (United States)

    Robinson, R; Swaby, G; Sutton, T; Fife, C; Powell, M; Butler, B D

    1997-11-01

    Physiological studies of the effects of high altitude on man often require the use of a hypobaric chamber to simulate the reduced ambient pressures. Typical "altitude" chambers in use today require complex mechanical vacuum systems to evacuate the chamber air, either directly or via reservoir system. Use of these pumps adds to the cost of both chamber procurement and maintenance, and service of these pumps requires trained support personnel and regular upkeep. In this report we describe use of venturi vacuum pumps to perform the function of mechanical vacuum pumps for human and experimental altitude chamber operations. Advantages of the venturi pumps include their relatively low procurement cost, small size and light weight, ease of installation and plumbing, lack of moving parts, and independence from electrical power sources, fossil fuels and lubricants. Conversion of three hyperbaric chambers to combined hyper/hypobaric use is described.

  19. Study of the impact of environmental parameters on the operation of CMS RPCs

    CERN Document Server

    Assran, Yasser

    2011-01-01

    CMS (Compact Muon Solenoid) is a general purpose detector designed to run at the highest luminosity at Large Hadron Collider (LHC), CERN, Geneva, Switzerland. The muon system of the CMS experiment relies on Drift Tubes (DT), Cathode Strip Chambers (CSC) and Resistive Plate Chambers (RPC). RPCs are dedicated for the first level muon trigger and they are characterized by bakelite electrodes delimited in a specialized gas volume filled with operational gas mixture. This analysis has been done for the RPC chambers installed in CMS experiment at CERN. The Currents of CMS RPCs chambers are analyzed as a function of environmental parameters such as Temperature, Humidity and pressure, which are important for the operation of the muon detector system. A novel Neural Network approach has been used to analyze the data and to build a model using experimental measurements and combining the results of the simulations. Data from RPC Chambers in CMS experiment are taken and compared to the results from neural Network.

  20. Diogene pictorial drift chamber

    International Nuclear Information System (INIS)

    Gosset, J.

    1984-01-01

    A pictorial drift chamber, called DIOGENE, has been installed at Saturne in order to study central collisions of high energy heavy ions. It has been adapted from the JADE internal detector, with two major differences to be taken into account. First, the center-of-mass of these collisions is not identical to the laboratory reference frame. Second, the energy loss and the momentum ranges of the particles to be detected are different from the ones in JADE. It was also tried to keep the cost as small as possible, hence the choice of minimum size and minimum number of sensitive wires. Moreover the wire planes are shifted from the beam axis: this trick helps very much to quickly reject the bad tracks caused by the ambiguity of measuring drift distances (positive or negative) through times (always positive)

  1. Evaluation of temperature variation in pulp chamber after high power diode laser irradiation (λ=830 nm) on dental enamel: 'in vitro' study

    International Nuclear Information System (INIS)

    Macri, Rodrigo Teixeira

    2001-01-01

    The aim of this study was to observe the variation of temperature in the pulp chamber caused by irradiation of a commercial diode laser operating in continuous wave with wavelength 830 nm over the dental enamel. In the first part of this study, two types of tooth models were tested: 3,5 mm slice and whole tooth. In the second part, we irradiated the buccal si de of the enamel in 2 primary lower incisors from cattle with Opus 10 diode laser for 10 s with power levels of 1 W and 2 W, always using an absorber. Two thermocouples were used. The first one was inserted in the dentin wall closest to the irradiation site, while the second was inserted in the middle of the pulp chamber. It was observed that the thermocouples registered different temperatures. Always, the dentin thermocouple registered higher temperatures. Considering the dentin records, the irradiation of 1 W for 10 s can be safe for the pulp. Further studies must be developed related to the correct positioning of the thermocouples inside the pulp chamber. This was a first step of using diode laser in enamel, and in this study, we concluded that the Opus 10 diode laser shown to be safe for this use, with 1 W power for 10 S. (author)

  2. Performance studies of a time projection chamber at the ILC and search for lepton flavour violation at HERA II

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, M.E.

    2008-05-15

    It is expected, that new physics beyond the Standard Model can be discovered in the energy range of 1TeV. One of the next projects in high energy physics will be a linear collider. A proposal for such a machine is the International Linear Collider (ILC), where electrons and positrons are brought to collision with a centre of mass energy up to 500 GeV with the possibility to upgrade it to 1 TeV. The precision measurement of this new physics sets high requirements on the performance of the detector at the ILC. As the main tracking device for a detector at the ILC, a Time Projection Chamber (TPC) has been proposed. To reach these requirements a new amplification techniques based on Micro Pattern Gas Detectors (MPGD) is under investigation. In this thesis, data are analysed, that were taken using the prototype MediTPC, whose amplification system is based on Gas Electron Multipliers (GEM). Different magnetic fields of up to 4 T, two gas mixtures and differed arrangement of the pads have also been investigated. The main part of this thesis deals with the study of the performance of two different approaches to determine track parameters. A new method based on a likelihood fit of the expected charge to the measured one is compared to a traditional approach using reconstructed space points and a {chi}{sup 2} minimisation technique. Different aspects such as the performance in the presence of non working channels and the angular dependency are investigated. Finally the determined spatial resolution (in the r{phi}-plane) is presented. At zero drift length a resolution of the order of 100 {mu}m can be achieved. In the second part of this thesis the results of a search for lepton flavour violation mediated by leptoquarks is presented. Data of electron-proton collisions with a centre-of-mass energy of 320 GeV taken with the H1 experiment are investigated. The analysis concentrates of the e{sup -}p data of the HERAII phase, which were taken in the years 2004-2006. They correspond

  3. Measurements of VOC fluxes by dynamic plant and soil chambers in wheat and maize crop near Paris with a PTR-Qi-TOF-MS: Quantification and response to environmental and physiological drivers.

    Science.gov (United States)

    Gonzaga-Gomez, Lais; Boissard, Christophe; Ciuraru, Raluca; Lafouge, Florence; Zurfluh, Olivier; Buysse, Pauline; Decuq, Céline; Fanucci, Olivier; Gueudet, Jean-Christophe; Gros, Valérie; Sarda, Roland; Zannoni, Nora; Loubet, Benjamin

    2017-04-01

    Volatile organic compounds (VOC) play an important role in the chemistry of the atmosphere as precursors of secondary pollutants such as ozone and organic aerosols. A large variety of VOC are exchanged between plants (BVOC) and the atmosphere. Their fluxes are strongly dependent on environmental factors (temperature, light, biotic and abiotic stress) and vary greatly among plant species. Only few studies focused on BVOC emissions by agricultural plants and were mostly carried in North America. However, agricultural lands occupy 51% of the total country area in France, with wheat being one of the most important crop. We used a PTR-Qi-TOF-MS (national instrument within the ANAEE-France framework) and dynamic chambers to measure BVOC emissions from plant and soil compartments of a wheat and a maize crop near Paris (FR-GRI ICOS site). More than 700 masses were detected thanks to the resolution and sensitivity of this new instrument. We analyze the emission response to light, temperature and stomatal aperture in order to explain the mechanisms of BVOC exchanges by wheat plants. We investigate the emission differences between soil and plant compartment, and between wheat and maize crops. Acetone (m/z 59.049) was the predominant volatile compound in the emissions from wheat. Both methanol (m/z 33.033) and acetaldehyde (m/z 45.033) were also quite abundantly emitted but were less than half the acetone emissions. Other masses detected in relative importance in this study were m/z 63.026 (possible DMS), m/z 93.033 (not identified), m/z 69.069 (isoprene), m/z 57.069 (not identified), m/z 83.085 (possible green leaf volatiles), m/z 73.064 (methyl ethyl ketone). Their emissions were around 7 times smaller than the emissions of acetone. On the other hand we observed a deposition for, mainly, m/z 75.044 (hydroxyacetone) and m/z 61.028 (acetic acid). Methanol presented both positive and negative fluxes witch could indicate either emission or absorption of this compound by the

  4. The Mark II Vertex Drift Chamber

    International Nuclear Information System (INIS)

    Alexander, J.P.; Baggs, R.; Fujino, D.

    1989-03-01

    We have completed constructing and begun operating the Mark II Drift Chamber Vertex Detector. The chamber, based on a modified jet cell design, achieves 30 μm spatial resolution and 2 gas mixtures. Special emphasis has been placed on controlling systematic errors including the use of novel construction techniques which permit accurate wire placement. Chamber performance has been studied with cosmic ray tracks collected with the chamber located both inside and outside the Mark II. Results on spatial resolution, average pulse shape, and some properties of CO 2 mixtures are presented. 10 refs., 12 figs., 1 tab

  5. Investigation of very long jet chambers

    Energy Technology Data Exchange (ETDEWEB)

    Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P

    1986-04-01

    The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP. (orig.).

  6. Investigation of very long jet chambers

    Energy Technology Data Exchange (ETDEWEB)

    Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P

    1986-04-01

    The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP.

  7. A comparative study of the work involved in measuring profiles using ion chambers, a linear diode array and film

    International Nuclear Information System (INIS)

    Rykers, K.L.; RMIT University, Melbourne, VIC; Royal North Shore Hospital, St Leonards, NSW; Geso, M.; Brown, G.M.; Olilver, L.D.

    1996-01-01

    Full text: The usefulness of film to perform dosimetric measurement is a topic often discussed and not clearly agreed upon. While single point measurement detectors give consistent and reliable results for physically wedged fields they cannot be easily used to measure intensity modulated fields. In this work a method of using film to measure profiles for dynamically wedged (DW) fields is presented. The method of positioning film for the subsequent generation of a conversion function to allow for the variation in films' response with energy is outlined. Furthermore, the profiles determined by film measurement are compared with those measured with single point measurement detector and an array of silicon diodes. Both Leavitt et. al. 8 and Weber et. al. 7 have reported on the successful use of the linear diode array (LDA) in measuring dynamic wedge data. This claim will be investigated. The film used in this work was Kodak X-Omat V. The solid water was RW3 with high water equivalency in the range from 137 CS to 50 MV for photons and electrons. All films were processed in an automatic processor. Both the Wellhoefer and the Scanditronix RFA 300 densitometers were used to take film readings. Wedged field and open field profiles measurements were taken in water using both the Wellhoefer IC-10 chamber, the Scanditronix RFA 300 RK chamber and the Scanditronix LDA . The energy investigated was 6 MV at 1.5, 5.0, 10.0, 15.0 and 20.0 cm for a Varian 2100C machine. More consistent density readings were obtained when films were processed with the edge of the film that was parallel to the beam axis was fed into the processor first; rather than when the beam incident edge was fed into the processor first. Comparing the position of the central axis (CAX) of open films from the geometric method developed in this work to the software determined CAX (as available with the Wellhoefer software), it was found that the difference in CAX positions varied between -0.03 to +0.04 cm at 2.5 cm

  8. A study of photochemical againg of ambient air using Potential Aerosol Mass (PAM) chamber under the different sources and types of emissions

    Science.gov (United States)

    Lee, T.; Son, J.; Kim, J.; Kim, S.; Sung, K.; Park, G.; Link, M.; Park, T.; Kim, K.; Kang, S.; Ban, J.; Kim, D. S.

    2016-12-01

    Recent research proposed that Secondary Aerosol (SA) is important class of predicting future climate change scenarios, health effect, and a general air quality. However, there has been lack of studies to investigate SA formation all over the world. This study tried to focus on understanding potential secondary aerosol formation and its local impact by the photochemical aging of inorganic and organic aerosols in the ambient air using the Potential Aerosol Mass (PAM) chamber under the different sources and types of emissions. PAM chamber manufactured by Aerodyne make an oxidizing environment that simulates oxidation processes on timescales of 12-15 hrs in the atmosphere. Chemical compositions of ambient aerosol and aerosol that was aged in the PAM chamber were alternately measured every 2-minutes using the High Resolution-Time of Flight-Aerosol Mass Spectrometer (HR-ToF-AMS). HR-ToF-AMS provides non-refractory aerosol mass concentrations including nitrate, sulfate, hydrocarbon-like and oxygenated organic aerosol in real time. This study includes a residence area of mixture of sources, a forest site of dominant source of biogenic VOCs, an underground parking lot of dominant vehicle emission, and laboratory experiment of vehicle emissions under different fuels and speeds using the chassis dynamometer. As a result, it was revealed that gasoline and LPG vehicle relatively made more potential SA than diesel vehicle.

  9. Environmental Studies Group progress report for 1979

    International Nuclear Information System (INIS)

    Hunt, D.C.; Hurley, J.D.

    1981-01-01

    The 1979 progress report gives descriptions, results, and/or status on programs involving (1) physical transport of radionuclides in blowing dust, (2) radionuclide distributions in the sediment of area water bodies, (3) management of open space lands (including a remote sensing program) at Rocky Flats, (4) the ecology and radioecology of terrestrial open space areas in Plant site lands, (5) biological pathways for radionuclide transport, (6) evaluations of environmental monitoring data on radionuclides in air and water, (7) results of a special soil sampling program on lands adjacent to the Plant site, and (8) two special programs - one concerning evaluations of epidemiological studies of health effects purported to be related to the Plant, and a second that specifies information on accumulations of material in process building filter plenums required for evaluation of potential accidents

  10. Environmental Comparative Risk Assessment: A Case Study

    International Nuclear Information System (INIS)

    Ali, M.M.

    2007-01-01

    Health and environmental impacts associated with energy production and industrial activities as well as food production and agricultural activities have had great concern in the last decades. Early activities emerged in late 80s of the last century through an Inter- Agency project (lAEA, UNDY, WHO, ... ) on the comparative risk assessment from energy systems and industrial complexes. A work-shop on Risk Assessment and Management in large industrial areas was held in Alexandria Egypt on 20-33 Det 1993, sponsored by IAEA. Several conferences, experts work groups and workshops were held there of Recent trends in determining risks are: 1. Use of probabilistic risk assessment approach to identify hazardous activities and accident scenario. 2. development of data base on failure probabilities and appropriate physical models. 3. Development of related directives and regulations and criteria Comparative risk assessment case study as a tool for comparing risk is emphasized Criteria of exposure to human and ecological risks are addressed

  11. Joint HVAC transmission EMF environmental study

    Energy Technology Data Exchange (ETDEWEB)

    Stormshak, F.; Thompson, J. (Oregon State Univ., Corvallis, OR (United States))

    1992-05-01

    This document describes the rationale, procedures, and results of a carefully controlled study conducted to establish whether chronic exposure of female (ewe) Suffolk lambs to the environment of a 500-kV 60-Hz transmission line would affect various characteristics of growth, endocrine function, and reproductive development. This experiment used identical housing and management schemes for control and line-exposed ewes, thus minimizing these factors as contributors to between-group experimental error. Further, throughout the 10-month duration of this study, changes in electric and magnetic fields, audible noise, and weather conditions were monitored continuously by a computerized system. Such measurements provided the opportunity to identify any relationship between environmental factors and biological responses. Because of reports in the literature that electric and magnetic fields alter concentrations of melatonin in laboratory animals, the primary objective of this study was to ascertain whether a similar effect occurs in lambs exposed to a 500-kV a-c line in a natural setting. In addition, onset of puberty, changes in body weight, wool growth, and behavior were monitored. To determine whether the environment of a 500-kV line caused stress in the study animals, serum levels of cortisol were measured. The study was conducted at Bonneville Power Administration's Ostrander Substation near Estacada, Oregon.

  12. Chemical and physical transformations of organic aerosol from the photo-oxidation of open biomass burning emissions in an environmental chamber

    Directory of Open Access Journals (Sweden)

    C. J. Hennigan

    2011-08-01

    Full Text Available Smog chamber experiments were conducted to investigate the chemical and physical transformations of organic aerosol (OA during photo-oxidation of open biomass burning emissions. The experiments were carried out at the US Forest Service Fire Science Laboratory as part of the third Fire Lab at Missoula Experiment (FLAME III. We investigated emissions from 12 different fuels commonly burned in North American wildfires. The experiments feature atmospheric and plume aerosol and oxidant concentrations; aging times ranged from 3 to 4.5 h. OA production, expressed as a mass enhancement ratio (ratio of OA to primary OA (POA mass, was highly variable. OA mass enhancement ratios ranged from 2.9 in experiments where secondary OA (SOA production nearly tripled the POA concentration to 0.7 in experiments where photo-oxidation resulted in a 30 % loss of the OA mass. The campaign-average OA mass enhancement ratio was 1.7 ± 0.7 (mean ± 1σ; therefore, on average, there was substantial SOA production. In every experiment, the OA was chemically transformed. Even in experiments with net loss of OA mass, the OA became increasingly oxygenated and less volatile with aging, indicating that photo-oxidation transformed the POA emissions. Levoglucosan concentrations were also substantially reduced with photo-oxidation. The transformations of POA were extensive; using levoglucosan as a tracer for POA, unreacted POA only contributed 17 % of the campaign-average OA mass after 3.5 h of exposure to typical atmospheric hydroxyl radical (OH levels. Heterogeneous reactions with OH could account for less than half of this transformation, implying that the coupled gas-particle partitioning and reaction of semi-volatile vapors is an important and potentially dominant mechanism for POA processing. Overall, the results illustrate that biomass burning emissions are subject to extensive chemical processing in the atmosphere, and the timescale for these transformations is rapid.

  13. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  14. TRU waste characterization chamber gloveboxes

    International Nuclear Information System (INIS)

    Duncan, D. S.

    1998-01-01

    Argonne National Laboratory-West (ANL-W) is participating in the Department of Energy's (DOE) National Transuranic Waste Program in support of the Waste Isolation Pilot Plant (WIPP). The Laboratory's support currently consists of intrusive characterization of a selected population of drums containing transuranic waste. This characterization is performed in a complex of alpha containment gloveboxes termed the Waste Characterization Gloveboxes. Made up of the Waste Characterization Chamber, Sample Preparation Glovebox, and the Equipment Repair Glovebox, they were designed as a small production characterization facility for support of the Idaho National Engineering and Environmental Laboratory (INEEL). This paper presents salient features of these gloveboxes

  15. Climatic chamber for plant physiology: a new project concept

    International Nuclear Information System (INIS)

    Materassi, A.; Fasano, G.; Arca, A.

    2005-01-01

    The two climatic chambers proposed here were designed and built for both general environmental physiology and specific studies on the effect of ultraviolet radiation on plants. The two chambers differ only for the fact that one of them, in addition to solar spectrum lamps, also has lamps which emit UV-B radiation. The environmental parameters taken into consideration are: luminous and UV-B radiation, air temperature and humidity, ozone and carbon dioxide concentration and air movement. Radiation can be continuously regulated, thus permitting simulation of twilight increasing and decreasing at the beginning and end of the photoperiod. Temperature cycles can be imposed between 5 and 40 deg C, while, for relative humidity, values can be imposed between 30% and 80%. Concentration of O3 can be maintained at values much lower than 0.1 ppm, the maximum value compatible with biological activity; CO2 concentration can be brought up to 3,000 ppm. Air movement inside the chambers is assured by ventilators and aspirators mounted on the devices which carry out regulation of the other environmental parameters. The controls of the various quantities are performed using medium-low cost commercial devices, while high level software manages them. In this way, good quality control of the environmental parameters is obtained with a much lower construction cost compared to other climatic chambers. Moreover, the use of commercial actuators permits easier and more immediate maintenance. Functionality tests, carried out both in transient and in steady state, have demonstrated a complete correspondence between project specifications and obtained results [it

  16. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  17. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. Introduction to the study of boiling in swimming-pool reactors. Measurement of the efficiency of a CC5 chamber

    International Nuclear Information System (INIS)

    Froelicher, B.

    1967-01-01

    The efficiency of a CC5 ionisation chamber has been evaluated by a rough measurement: by integrating the relationship P(f) = ε F0 (1 + ε A) over the band width of the apparatus, it is possible to show the influence of ε. This conventional method of operation is not very precise and so a more realistic value of the efficiency will be derived later using the plot of the low power transfer function of the reactor Ulysse, this being a more exact method. (author) [fr

  19. Measurements of the relative backscatter contribution to the monitor chamber for modern medical linear accelerators; A multi-center study

    DEFF Research Database (Denmark)

    Sibolt, Patrik; Cronholm, Rickard O.; Beierholm, Anders Ravnsborg

    2015-01-01

    Conversion to absolute dose in Monte Carlo (MC) simulations of MV radiotherapy beams needs correct modeling of backscatter (BS) to the linear accelerator (linac) monitor chamber. For some linacs the BS depends largely on jaw settings. The backscattered fraction (BSF) of radiation can be determined...... BSF measurements were compared with MC simulations performed using the BEAMnrc user code. For flattened beams on the Varian linacs, the measured BSF exhibited a clear linear correlation with square jaw settings (correlation coefficient r > 0.9 with p

  20. Chambers versus Relaxed Eddy Accumulation: an intercomparison study of two methods for short-term measurements of biogenic CO2 fluxes

    Science.gov (United States)

    Jasek, Alina; Zimnoch, Miroslaw; Gorczyca, Zbigniew; Chmura, Lukasz; Necki, Jaroslaw

    2014-05-01

    The presented work is a part of comprehensive study aimed at thorough characterization of carbon cycle in the urban environment of Krakow, southern Poland. In the framework of this study two independent methods were employed to quantify biogenic CO2 flux in the city: (i) closed chambers, and (ii) Relaxed Eddy Accumulation (REA). The results of a three-day intensive intercomparison campaign performed in July 2013 and utilizing both measurement methods are reported here. The chamber method is a widely used approach for measurements of gas exchange between the soil and the atmosphere. The system implemented in this study consisted of a single chamber operating in a closed-dynamic mode, combined with Vaisala CarboCAP infrared CO2 sensor in a mobile setup. An alternative flux measurement method, covering larger area is represented by REA, which is a modification of the eddy covariance method. It consists of a 3D anemometer (Gill Windmaster Pro) and the system collecting updraft and downdraft samples to 5-litre Tedlar bags. The CO2 mixing ratios in the collected samples are measured by Picarro G2101i analyzer. The setup consists of two sets of bags so that the sampling can be performed continuously with 15-min temporal resolution. A 48-hectares open meadow located close the city center was chosen as a test site for comparison of the two methods of CO2 flux measurements outlined above. In the middle of the meadow a 3-metre high tripod was installed with the anemometer and REA inlet system. For a period of 46 hours the system was measuring net CO2 flux from the surrounding area. A meteorological conditions and intensity of photosynthetically active radiation (PAR) were also recorded. In the same time, CO2 flux from several points around the REA inlet was measured with the chamber system, resulting in 93 values for both respiration and net CO2 flux. Chamber results show rather homogenous distribution of the soil CO2 flux (the mean value equal to 40.9 ± 2.2 mmol/m2h), with

  1. A practical approach to estimate emission rates of indoor air pollutants due to the use of personal combustible products based on small-chamber studies.

    Science.gov (United States)

    Szulejko, Jan E; Kim, Ki-Hyun

    2016-02-01

    As emission rates of airborne pollutants are commonly measured from combusting substances placed inside small chambers, those values need to be re-evaluated for the possible significance under practical conditions. Here, a simple numerical procedure is investigated to extrapolate the chamber-based emission rates of formaldehyde that can be released from various combustible sources including e-cigarettes, conventional cigarettes, or scented candles to their concentration levels in a small room with relatively poor ventilation. This simple procedure relies on a mass balance approach by considering the masses of pollutants emitted from source and lost through ventilation under the assumption that mixing occurs instantaneously in the room without chemical reactions or surface sorption. The results of our study provide valuable insights into re-evaluation procedure of chamber data to allow comparison between extrapolated and recommended values to judge the safe use of various combustible products in confined spaces. If two scented candles with a formaldehyde emission rate of 310 µg h(-1) each were lit for 4 h in a small 20 m(3) room with an air change rate of 0.5 h(-1), then the 4-h (candle lit) and 8-h (up to 8 h after candle lighting) TWA [FA] were determined to be 28.5 and 23.5 ppb, respectively. This is clearly above the 8-h NIOSH recommended exposure limit (REL) time weighted average of 16 ppb. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Acoustic-Levitation Chamber

    Science.gov (United States)

    Barmatz, M. B.; Granett, D.; Lee, M. C.

    1984-01-01

    Uncontaminated environments for highly-pure material processing provided within completely sealed levitation chamber that suspends particles by acoustic excitation. Technique ideally suited for material processing in low gravity environment of space.

  3. Optical spark chamber

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    An optical spark chamber developed for use in the Omega spectrometer. On the left the supporting frame is exceptionally thin to allow low momentum particles to escape and be detected outside the magnetic field.

  4. Vacuum chamber 'bicone'

    CERN Multimedia

    1977-01-01

    This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).

  5. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  6. Reference ionization chamber

    International Nuclear Information System (INIS)

    Golnik, N.; Zielczynski, M.

    1999-01-01

    The paper presents the design of ionization chamber devoted for the determination of the absolute value of the absorbed dose in tissue-equivalent material. The special attention was paid to ensure that the volume of the active gas cavity was constant and well known. A specific property of the chamber design is that the voltage insulators are 'invisible' from any point of the active volume. Such configuration ensures a very good time stability of the electrical field and defines the active volume. The active volume of the chamber was determined with accuracy of 0.3%. This resulted in accuracy of 0.8% in determination of the absorbed dose in the layer of material adherent to the gas cavity. The chamber was applied for calibration purposes at radiotherapy facility in Joint Institute for Nuclear Research in Dubna (Russia) and in the calibration laboratory of the Institute of Atomic Energy in Swierk. (author)

  7. Gridded ionization chamber

    International Nuclear Information System (INIS)

    Houston, J.M.

    1977-01-01

    An improved ionization chamber type x-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is disposed adjacent the anode and is maintained at a voltsge intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting toward the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  8. ALICE Time Projection Chamber

    CERN Multimedia

    Lippmann, C

    2013-01-01

    The Time Projection Chamber (TPC) is the main device in the ALICE 'central barrel' for the tracking and identification (PID) of charged particles. It has to cope with unprecedented densities of charges particles.

  9. Study on the subject system of environmental radiochemistry

    International Nuclear Information System (INIS)

    Qiang Yi zhong

    1992-11-01

    The environmental radiochemistry is a new frontier discipline. So, it is very important to study the system of this subject. A brief introduction of its development background and history are presented. The definition of the environmental radiochemistry has been studied. Main contents containing in the subject have been classified and reviewed in accordance with different modalities. Five major features of the environmental radiochemistry are suggested. Issues to be considered recently in the environmental radiochemistry are also discussed

  10. Improved climatic chamber for desiccation simulation

    Directory of Open Access Journals (Sweden)

    Lozada Catalina

    2016-01-01

    Full Text Available The climatic chamber at the Universidad de Los Andes was improved for modeling desiccation in soil layers. This chamber allows the measurement of different environmental variables. In this research, evaporation tests were conducted in water imposing boundary conditions for drying, and then these tests were performed in a soil layer. The soil was prepared from a slurry state and was drying controlling the temperature, the infrared radiation, the wind velocity, and the relative humidity. In the first part of this paper, a description of the climatic chamber, operation ranges and theoretical work principles of the climatic chamber are presented. Then, the second part shows the results for desiccation in water and soil. The desiccation tests performed with the climatic chamber allow simulating all environmental conditions accurately during drying coupling the effect of all environmental variables. As a result, the evaporation rate increases with infrared radiation in soil and water. The rate at the beginning of the desiccation tests in clays is the same as in water. However, this evaporation rate decreases as the soil becomes desiccated.

  11. A Study on improvement of environmental assessment system in social, economic, and environmental sectors

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Young Sook; Koo, Doh Wan; Keum, Kee Yong [Korea Environment Institute, Seoul (Korea)

    1998-12-01

    The environmental assessment system is assessed as a mechanism that can achieve the goal for environmental policy in 21st century. As it can evaluate social and economic feasibility of large-scale development program, this system can achieve a sustainable society by mitigating social conflicts arising from environmental problems. For making the environmental assessment system substantial, this study was implemented by the need of improvement of the system, by analyzing problems of social, economic, and environmental evaluation, which is implemented under the present system. 44 refs., 1 fig., 25 tabs.

  12. Scattering study at free air ionization chamber diaphragm; Estudo do espalhamento no diafragma da camara de ionizacao de ar livre

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Alexandre Lo Bianco dos

    2011-07-01

    The maim of this work consisted in the assessment of the correction factor for air kerma, due to scattered radiation in the diaphragm of the free-air ionization chamber model 481. LNMRl measurements were made to acquire x-ray spectra corresponding to the Qualities RQR-M, described in IEC 61627 standards (2005). These spectra were used as input data in the MC simulations. The operational range of energy spectra provide up to 35 keV. This energy range is typically used in diagnostic radiology, although there is not primary standard for air kerma. The determination of this factor is a fundamental process in the primary standardization of the air kerma. These factors were obtained by computer simulation using the Penelope code. The results are k{sub RQR-M1}=0,9946, k{sub RQR} {sub -M2}=0,9932, k{sub RQR-M3}=0,9978 and k{sub RQR-M4}=0,9885; with uncertainties of 0,007 and coverage factor equal to 2. lt can be concluded that, with respect to the diaphragm, the chamber can be used in the primary standard of air kerma. (author)

  13. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    Manero Amoros, F.

    1962-01-01

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  14. Bubble chamber: antiproton annihilation

    CERN Multimedia

    1971-01-01

    These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  15. A multi-component parallel-plate flow chamber system for studying the effect of exercise-induced wall shear stress on endothelial cells.

    Science.gov (United States)

    Wang, Yan-Xia; Xiang, Cheng; Liu, Bo; Zhu, Yong; Luan, Yong; Liu, Shu-Tian; Qin, Kai-Rong

    2016-12-28

    In vivo studies have demonstrated that reasonable exercise training can improve endothelial function. To confirm the key role of wall shear stress induced by exercise on endothelial cells, and to understand how wall shear stress affects the structure and the function of endothelial cells, it is crucial to design and fabricate an in vitro multi-component parallel-plate flow chamber system which can closely replicate exercise-induced wall shear stress waveforms in artery. The in vivo wall shear stress waveforms from the common carotid artery of a healthy volunteer in resting and immediately after 30 min acute aerobic cycling exercise were first calculated by measuring the inner diameter and the center-line blood flow velocity with a color Doppler ultrasound. According to the above in vivo wall shear stress waveforms, we designed and fabricated a parallel-plate flow chamber system with appropriate components based on a lumped parameter hemodynamics model. To validate the feasibility of this system, human umbilical vein endothelial cells (HUVECs) line were cultured within the parallel-plate flow chamber under abovementioned two types of wall shear stress waveforms and the intracellular actin microfilaments and nitric oxide (NO) production level were evaluated using fluorescence microscope. Our results show that the trends of resting and exercise-induced wall shear stress waveforms, especially the maximal, minimal and mean wall shear stress as well as oscillatory shear index, generated by the parallel-plate flow chamber system are similar to those acquired from the common carotid artery. In addition, the cellular experiments demonstrate that the actin microfilaments and the production of NO within cells exposed to the two different wall shear stress waveforms exhibit different dynamic behaviors; there are larger numbers of actin microfilaments and higher level NO in cells exposed in exercise-induced wall shear stress condition than resting wall shear stress condition

  16. Sleeve reaction chamber system

    Science.gov (United States)

    Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA

    2009-08-25

    A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.

  17. Environmental studies using earth orbital photography

    Energy Technology Data Exchange (ETDEWEB)

    Wobber, F J

    1969-01-01

    Orbital remote sensing, and particularly orbital photography, can provide immediately useful data for scientists familiar with applying aerial photographic techniques to environmental problems. Despite the expansion of analytical techniques in the earth sciences, the environmental data base has remained relatively static compared with increased information needs because of the difficulty of effective worldwide surveys and the high cost of timely data collection. Color, color infrared and black and white space photographs obtained incident to the Gemini and Apollo programs provide unique synoptic tools for analyzing modern environments and processes, and data that cannot be duplicated by aerial photographic mosaics. Principal advantages of orbital surveys include repetitious worldwide coverage promising environmental synthesis within the full spectrum of seasonal contrasts, and synoptic observations on a scale generally impossible from aircraft. The general categories of environmental data that can be extracted from orbital photography are summarized. 26 references, 37 figures, 3 tables.

  18. Comparative study of environmental impact assessment methods ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-07-20

    Jul 20, 2009 ... 3Department of Environmental Health, School of Public Health, Ahvaz University of Medical Sciences, Ahvaz, Iran. .... lines in a virtual place aiming at goals opportunity. .... available to show the reality of quantitative model.

  19. Smog chamber study on aging of combustion soot in isoprene/SO2/NOx system: Changes of mass, size, effective density, morphology and mixing state

    Science.gov (United States)

    Li, Kangwei; Chen, Linghong; Han, Ke; Lv, Biao; Bao, Kaiji; Wu, Xuecheng; Gao, Xiang; Cen, Kefa

    2017-02-01

    Atmospheric soot aging process is always accompanied by secondary particle formation, which is a comprehensive environmental issue that deserves great attention. On one hand, aging of primary soot could change its own physicochemical properties; on the other hand, complex air pollution caused by pollutant emission from various sources (e.g., vehicle exhausts, coal-fired flue gases and biogenic VOCs emission) may contribute to secondary particle formation onto primary particle surface. In this study, aging of combustion soot in isoprene/SO2/NOx system was investigated under controlled laboratory conditions in several smog chamber experiments. During the evolution of soot, several physical properties such as mass, size, effective density, morphology and mixing state were determined simultaneously by an integrated aerosol analytical system of Scanning Mobility Particle Sizer (SMPS), Differential Mobility Analyzer-Aerosol Particle Mass Analyzer-Condensation Particle Counter (DMA-APM-CPC) and Transmission Electron Microscopy coupled with Energy-dispersive X-ray Spectrometry (TEM/EDX) techniques. Here, based on the experimental results of soot aging under different gas-phase composition and relative humidity (RH), we firstly proposed possible aging pathways of soot in isoprene/SO2/NOx system. A synergetic effect was speculated to exist between SO2 and isoprene on soot aging process, which led to more secondary particle formation. At the same time, TEM/EDX analysis showed that a competitive mechanism between H2SO4(g) and isoprene oxidation vapor may exist: H2SO4(g) firstly condensed onto fresh soot, then an acceleration of isoprene oxidation products formed onto H2SO4 pre-coated soot. In isoprene/SO2/NOx system, high RH conditions could contribute to soot aging and new particle formation. The changes of effective density and dynamic shape factor of soot also indicated that high RH conditions could accelerate soot aging process, and led chain-like soot into more spherical

  20. Diogene: A 4π detector, based on a time projection chamber, for studying central collisions of relativistic heavy ions

    International Nuclear Information System (INIS)

    Gosset, J.

    1981-01-01

    'Diogene' is the name we have chosen for a 4π solid angle detector, based on a Time Projection Chamber, designed to perform exclusive measurements of charged particles emitted in central collisions or relativistic heavy ions. This detector is being developed by a collaboration between physicists from Saclay, Strasbourg and Clermont Ferrand, to be installed at the Saturne Synchrotron in Saclay. I first give the motivations for our choice of a TPC rather than any other kind of detector, then I recall the principle of such a detector, before describing it with more detail and describing its present status and forsean capabilities, including some discussion about the possible extension of such a detector towards higher energies and/or heavier beams. (orig.)

  1. Diogene: a 4π detector, based on a time projection chamber, for studying central collisions of relativistic heavy ions

    International Nuclear Information System (INIS)

    Gosset, J.

    1980-10-01

    'Diogene' is the name we have chosen for a 4π solid angle detector, based on a Time Projection Chamber (TPC), designed to perform exclusive measurements of charged particles emitted in central collisions or relativistic heavy ions This detector is being developed by a collaboration between physicists from Saclay, Strasbourg and Clermont-Ferrand, to be installed at the Saturne Synchrotron in Saclay. I shall first give the motivations for our choice of a TPC rather than any other kind of detector, than recall the principle of such a detector, before describing it with more detail and describing its present status and forsean capabilities, including some discussion about the possible extension of such a detector towards higher energies and/or heavier beams

  2. Studi Numerik Karakterisasi Aliran 3 Dimensi Multifase (Gas-Solid) Pada Gravity Settling Chamber Dengan Variasi Kecepatan Inlet Dan Diameter Partikel Pada Aliran Dilute Phase

    OpenAIRE

    Isa’i, Adi Mochammad; Widodo, Wawan Aries

    2013-01-01

    Kegiatan pemilahan pada aktivitas produksi merupakan salah satu kegiatan yang banyak dilakukan pada dunia industri. Penggunaan gravity settling chamber merupakan teknologi pemilahan partikel yang paling sedehana dan murah. Maka dalam perancangan suatu gravity settling chamber perlu diketahui parameter yang mempengaruhi kinerja dari alat tersebut. Analisa karakteristik aliran pada gravity settling chamber dilakukan dengan metode simulasi numerik menggunakan persamaan Eularian-Lagrangian. Sebu...

  3. Studi Numerik Karakterisasi Aliran 3 Dimensi Multifase (Gas-Solid) Pada Gravity Settling Chamber Dengan Variasi Kecepatan Inlet Dan Diameter Partikel Pada Aliran Dilute Phase

    OpenAIRE

    Adi Mochammad Isa’i; Wawan Aries Widodo

    2013-01-01

    Kegiatan  pemilahan pada aktivitas produksi merupakan salah satu kegiatan yang banyak dilakukan pada dunia industri. Penggunaan gravity settling chamber merupakan teknologi pemilahan partikel yang paling sedehana dan murah. Maka dalam perancangan suatu gravity settling chamber perlu diketahui parameter yang mempengaruhi kinerja dari alat tersebut. Analisa karakteristik aliran pada gravity settling chamber dilakukan dengan metode simulasi numerik menggunakan persamaan Eularian-Lagrangian. Sebu...

  4. Heat Acclimatization Protects the Left Ventricle from Increased Diastolic Chamber Stiffness Immediately after Coronary Artery Bypass Surgery: A Lesson from 30 Years of Studies on Heat Acclimation Mediated Cross Tolerance

    Directory of Open Access Journals (Sweden)

    Arthur Pollak

    2017-12-01

    Full Text Available During the period of 1986–1997 the first 4 publications on the mechanical and metabolic properties of heat acclimated rat's heart were published. The outcome of these studies implied that heat acclimation, sedentary as well as combined with exercise training, confers long lasting protection against ischemic/reperfusion insult. These results promoted a clinical study on patients with coronary artery disease scheduled for elective coronary artery bypass operations aiming to elucidate whether exploitation of environmental stress can be translated into human benefits by improving physiological recovery. During the 1998 study, immediate-post operative chamber stiffness was assessed in patients acclimatized to heat and low intensity training in the desert (spring in the Dead Sea, 17–33°C vs. patients in colder weather (spring in non-desert areas, 6–19°C via echocardiogram acquisition simultaneous with left atrial pressure measurement during fast intravascular fluid bolus administration. We showed that patients undergoing “heat acclimatization combined with exercise training” were less susceptible to ischemic injury, therefore expressing less diastolic dysfunction after cardiopulmonary bypass compared to non-acclimatized patients. This was the first clinical translational study on cardiac patients, while exploiting environmental harsh conditions for human benefits. The original experimental data are described and discussed in view of the past as well as the present knowledge of the protective mechanisms induced by Heat Acclimation Mediated Cross-tolerance.

  5. Fission Product Yield Study of 235U, 238U and 239Pu Using Dual-Fission Ionization Chambers

    Science.gov (United States)

    Bhatia, C.; Fallin, B.; Howell, C.; Tornow, W.; Gooden, M.; Kelley, J.; Arnold, C.; Bond, E.; Bredeweg, T.; Fowler, M.; Moody, W.; Rundberg, R.; Rusev, G.; Vieira, D.; Wilhelmy, J.; Becker, J.; Macri, R.; Ryan, C.; Sheets, S.; Stoyer, M.; Tonchev, A.

    2014-05-01

    To resolve long-standing differences between LANL and LLNL regarding the correct fission basis for analysis of nuclear test data [M.B. Chadwick et al., Nucl. Data Sheets 111, 2891 (2010); H. Selby et al., Nucl. Data Sheets 111, 2891 (2010)], a collaboration between TUNL/LANL/LLNL has been established to perform high-precision measurements of neutron induced fission product yields. The main goal is to make a definitive statement about the energy dependence of the fission yields to an accuracy better than 2-3% between 1 and 15 MeV, where experimental data are very scarce. At TUNL, we have completed the design, fabrication and testing of three dual-fission chambers dedicated to 235U, 238U, and 239Pu. The dual-fission chambers were used to make measurements of the fission product activity relative to the total fission rate, as well as for high-precision absolute fission yield measurements. The activation method was employed, utilizing the mono-energetic neutron beams available at TUNL. Neutrons of 4.6, 9.0, and 14.5 MeV were produced via the 2H(d,n)3He reaction, and for neutrons at 14.8 MeV, the 3H(d,n)4He reaction was used. After activation, the induced γ-ray activity of the fission products was measured for two months using high-resolution HPGe detectors in a low-background environment. Results for the yield of seven fission fragments of 235U, 238U, and 239Pu and a comparison to available data at other energies are reported. For the first time results are available for neutron energies between 2 and 14 MeV.

  6. General cavity theory in the dosimetry of X-rays. Experimental study with a high-pressure chamber

    International Nuclear Information System (INIS)

    Janssens, A.; Eggermont, G.; Jacobs, R.

    1978-01-01

    Consistent models have been constructed for the calculation of the stopping power ratio in the limiting cases of small and large cavity sizes. The direct application of this theory is inhibited by the lack of data on isotropic backscatter coefficients and the uncertainty in the appropriate interpolation procedure between the limiting cases. An experimental arrangement has been set up to yield confirmation of the theory and to provide the missing information. Measurements have been made of the ionization density in a parallel-plate chamber with gold walls, filled with air pressurized from 1 to 25 atm. The plate separation is 4 mm and the effective energy of the heavily filtered X-rays is 170 keV, such that quite a large of cavity sizes is covered, from about one tenth of the average electron range to about the maximum range. The collecting plate of the chamber consists of a 10 cm dia. collecting electrode surrounded by a 5 cm guard ring, such that no side wall effects occur. Through attenuation of the X-rays in the walls of the pressure vessel, the air mass and the gold foils, a large fluence of secondary photons is produced, which has been calculated with great accuracy. The experimental data and the calculated values of the stopping power ratio (air to gold) show good agreement, within the limits of confidence of the energy absorption coefficients. Further analysis of the data shows the need to use a 24% smaller value for the ratio of absorption coefficients (air to gold), and determines the energy backscatter coefficient of gold (bsub(en)=0.49) and the interpolation procedure. The consequences of applying cavity theory in dosimetry are discussed. (author)

  7. Environmental Studies and Environmental Science at GCE '0' and 'A' Level.

    Science.gov (United States)

    Gayford, Christopher G.

    1983-01-01

    Reports on environmental studies/science at General Certificate of Examination (GCE) ordinary ("0") and advanced ("A") levels. Questionnaires were used to survey teachers (focusing on their professional training and why they teach environmental studies/science courses) and to determine the relationship between environmental…

  8. Environmental impact study. 'Cyclical approach case study VEGA'

    International Nuclear Information System (INIS)

    Setzman, E.; Braennstroem-Norberg, B.M.; Rosen-Lidholm, S.

    1993-06-01

    The aim of this study has been to identify, describe and assess the environmental factors in the fuel chain which may be of significance for the possibilities of establishing biofuel-fired plants for the production of electricity and heat. The description is based on the documentation for the planned combined heat and power plant in Eskilstuna which will utilize pressurized gasification of biofuel in a combined cycle (VEGA). The study shows that the emissions from the plant are limited and do not give rise to any identifiable environmental effects. The emissions of nitrogen oxides from transportation and from fuel production are equivalent to those from combustion. The environmental consequences of a biofuel-fired plant of this size will be primarily local. The regional effects will be limited and of little significance providing that fuel extraction is not carried out in sensitive areas, transportation by road over long distances is minimized, and the removal of important nutrients through the extraction of biofuels is compensated for, for example by returning ash to the soil. 26 refs, 29 figs, 38 tabs

  9. Tritium environmental transport studies at TFTR

    International Nuclear Information System (INIS)

    Ritter, P.D.; Dolan, T.J.; Longhurst, G.R.

    1993-01-01

    Environmental tritium concentrations will be measured near the Tokamak Fusion Test Reactor (TFTR) to help validate dynamic models of tritium transport in the environment. For model validation the database must contain sequential measurements of tritium concentrations in key environmental compartments. Since complete containment of tritium is an operational goal, the supplementary monitoring program should be able to glean useful data from an unscheduled acute release. Portable air samplers will be used to take samples automatically every 4 hours for a weak after an acute release, thus obtaining the time resolution needed for code validation. Samples of soil, vegetation, and foodstuffs will be gathered daily at the same locations as the active air monitors. The database may help validate the plant/soil/air part of tritium transport models and enhance environmental tritium transport understanding for the International Thermonuclear Experimental Reactor (ITER)

  10. Tritium environmental transport studies at TFTR

    Science.gov (United States)

    Ritter, P. D.; Dolan, T. J.; Longhurst, G. R.

    1993-06-01

    Environmental tritium concentrations will be measured near the Tokamak Fusion Test Reactor (TFTR) to help validate dynamic models of tritium transport in the environment. For model validation the database must contain sequential measurements of tritium concentrations in key environmental compartments. Since complete containment of tritium is an operational goal, the supplementary monitoring program should be able to glean useful data from an unscheduled acute release. Portable air samplers will be used to take samples automatically every 4 hours for a week after an acute release, thus obtaining the time resolution needed for code validation. Samples of soil, vegetation, and foodstuffs will be gathered daily at the same locations as the active air monitors. The database may help validate the plant/soil/air part of tritium transport models and enhance environmental tritium transport understanding for the International Thermonuclear Experimental Reactor (ITER).

  11. Note: Small anaerobic chamber for optical spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chauvet, Adrien A. P., E-mail: adrien.chauvet@gmail.com; Chergui, Majed [Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratoire de Spectroscopie Ultrarapide, ISIC, Faculté des Sciences de Base, Station 6, 1015 Lausanne (Switzerland); Agarwal, Rachna; Cramer, William A. [Department of Biological Sciences, Purdue University, West Lafayette, Indiana 47907 (United States)

    2015-10-15

    The study of oxygen-sensitive biological samples requires an effective control of the atmosphere in which they are housed. In this aim however, no commercial anaerobic chamber is adequate to solely enclose the sample and small enough to fit in a compact spectroscopic system with which analysis can be performed. Furthermore, spectroscopic analysis requires the probe beam to pass through the whole chamber, introducing a requirement for adequate windows. In response to these challenges, we present a 1 l anaerobic chamber that is suitable for broad-band spectroscopic analysis. This chamber has the advantage of (1) providing access, via a septum, to the sample and (2) allows the sample position to be adjusted while keeping the chamber fixed and hermetic during the experiment.

  12. Environmental management in Slovenian industrial enterprises - Empirical study

    Directory of Open Access Journals (Sweden)

    Vesna Čančer

    2002-01-01

    Full Text Available timulated with the firm belief that environmental management helps enterprises to achieve business success, expressed by a majority of managers in the sample enterprises, we present the results of an empirical study in the Slovene processing industry. The purpose of our research work is to identify, analyse and present the importance of the environment in business decision-making, the role of environmental management in strategic decision-making and its distribution across the business functions; environmental performance in business processes; the use of the methods for environmentally oriented business decision-making and the developmental tendencies of environmental management in Slovene enterprises of the processing industry. We define the key drivers of environmental management and their effect on the environmental behaviour of these enterprises. We present and interpret data indicating that environmental management is caused not only by compliance and regulation, but also by competition and enterprises’ own initiative.

  13. On different experimental behaviour of fast secondary particles produced in 12C interactions at relativistic energies as studied with radiochemistry and in a propane chamber

    International Nuclear Information System (INIS)

    Kulakov, B.A.; Karachuk, J.; Gelovani, L.K.; Gridnev, T.G.; Sosnin, A.N.; Brandt, R.

    1998-01-01

    Energetic secondary fragments produced in the interaction of (41-44) GeV 12 C ions with copper exhibit experimentally a broader angular distribution as compared to energetic secondary fragments produced in the interactions at a lower 12 C-energy (15-25) GeV when studied with radiochemical techniques. Such a different experimental behaviour of secondary fragments produced by 12 C ions of the same two energy groups is not observed, when these secondary fragments are investigated with a propane bubble chamber. Separation of secondary particles is described

  14. A Study on Environmental Education Films.

    Science.gov (United States)

    Gerba, Diana

    The degree of communication between the film industry and educators and its effect on the future directions of environmental education films are the focus of this report. Separate surveys were mailed to 100 film industry producers and distributors and 150 elementary and secondary educators in Maine, Kansas, Pennsylvania, California, and Alabama.…

  15. Methods for environmental change; an exploratory study

    NARCIS (Netherlands)

    Nell Gottlieb; Robert Panne; Chris Smerecnik; Gerjo Kok

    2012-01-01

    Background: While the interest of health promotion researchers in change methods directed at the target population has a long tradition, interest in change methods directed at the environment is still developing. In this survey, the focus is on methods for environmental change; especially about how

  16. Environmental Health Ethics in Study of Children

    DEFF Research Database (Denmark)

    Knudsen, L. E.; Hansen, P. W.; Pedersen, M.

    2017-01-01

    Children are not small adults in relation to exposure and vulnerability. Rapid growth, development, and anatomical and physiological changes in various organs and organ systems differentiate children from adults in relation to exposure and vulnerability to environmental exposures. The unborn chil...

  17. An Environmental Unit for the Social Studies.

    Science.gov (United States)

    Kroll, Claudia J.

    Based on the inquiry method of learning, this instructional unit attempts to encourage students to discover for themselves the facts, problems, values, conflicts, and potential solutions of an environmental issue. Specifically, it deals with surface mining in the United States, with special focus on surface mining in Illinois. Materials and…

  18. Nickel oxide reduction studied by environmental TEM

    DEFF Research Database (Denmark)

    Jeangros, Q.; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    2012-01-01

    In situ reduction of an industrial NiO powder is performed under 1.3 mbar of H2 (2 mlN/min) in a differentially pumped FEI Titan 80-300 environmental transmission electron microscope (ETEM). Images, diffraction patterns and electron energy loss spectra (EELS) are acquired to monitor the structura...

  19. Wire chambers: Trends and alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Regler, Meinhard

    1992-05-15

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!.

  20. Methods for environmental change; an exploratory study.

    Science.gov (United States)

    Kok, Gerjo; Gottlieb, Nell H; Panne, Robert; Smerecnik, Chris

    2012-11-28

    While the interest of health promotion researchers in change methods directed at the target population has a long tradition, interest in change methods directed at the environment is still developing. In this survey, the focus is on methods for environmental change; especially about how these are composed of methods for individual change ('Bundling') and how within one environmental level, organizations, methods differ when directed at the management ('At') or applied by the management ('From'). The first part of this online survey dealt with examining the 'bundling' of individual level methods to methods at the environmental level. The question asked was to what extent the use of an environmental level method would involve the use of certain individual level methods. In the second part of the survey the question was whether there are differences between applying methods directed 'at' an organization (for instance, by a health promoter) versus 'from' within an organization itself. All of the 20 respondents are experts in the field of health promotion. Methods at the individual level are frequently bundled together as part of a method at a higher ecological level. A number of individual level methods are popular as part of most of the environmental level methods, while others are not chosen very often. Interventions directed at environmental agents often have a strong focus on the motivational part of behavior change.There are different approaches targeting a level or being targeted from a level. The health promoter will use combinations of motivation and facilitation. The manager will use individual level change methods focusing on self-efficacy and skills. Respondents think that any method may be used under the right circumstances, although few endorsed coercive methods. Taxonomies of theoretical change methods for environmental change should include combinations of individual level methods that may be bundled and separate suggestions for methods targeting a level

  1. Methods for environmental change; an exploratory study

    Directory of Open Access Journals (Sweden)

    Kok Gerjo

    2012-11-01

    Full Text Available Abstract Background While the interest of health promotion researchers in change methods directed at the target population has a long tradition, interest in change methods directed at the environment is still developing. In this survey, the focus is on methods for environmental change; especially about how these are composed of methods for individual change (‘Bundling’ and how within one environmental level, organizations, methods differ when directed at the management (‘At’ or applied by the management (‘From’. Methods The first part of this online survey dealt with examining the ‘bundling’ of individual level methods to methods at the environmental level. The question asked was to what extent the use of an environmental level method would involve the use of certain individual level methods. In the second part of the survey the question was whether there are differences between applying methods directed ‘at’ an organization (for instance, by a health promoter versus ‘from’ within an organization itself. All of the 20 respondents are experts in the field of health promotion. Results Methods at the individual level are frequently bundled together as part of a method at a higher ecological level. A number of individual level methods are popular as part of most of the environmental level methods, while others are not chosen very often. Interventions directed at environmental agents often have a strong focus on the motivational part of behavior change. There are different approaches targeting a level or being targeted from a level. The health promoter will use combinations of motivation and facilitation. The manager will use individual level change methods focusing on self-efficacy and skills. Respondents think that any method may be used under the right circumstances, although few endorsed coercive methods. Conclusions Taxonomies of theoretical change methods for environmental change should include combinations of individual

  2. DELPHI Barrel Muon Chamber Module

    CERN Multimedia

    1989-01-01

    The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.

  3. Can machine learning complement traditional medical device surveillance? A case-study of dual-chamber implantable cardioverter–defibrillators

    Directory of Open Access Journals (Sweden)

    Ross JS

    2017-08-01

    Full Text Available Joseph S Ross,1–4 Jonathan Bates,4 Craig S Parzynski,4 Joseph G Akar,4,5 Jeptha P Curtis,4,5 Nihar R Desai,4,5 James V Freeman,4,5 Ginger M Gamble,4 Richard Kuntz,6 Shu-Xia Li,4 Danica Marinac-Dabic,7 Frederick A Masoudi,8 Sharon-Lise T Normand,9,10 Isuru Ranasinghe,11 Richard E Shaw,12 Harlan M Krumholz2–5 1Section of General Medicine, Department of Medicine, 2Robert Wood Johnson Foundation Clinical Scholars Program, Yale School of Medicine, 3Department of Health Policy and Management, Yale School of Public Health, 4Center for Outcomes Research and Evaluation, Yale–New Haven Hospital, 5Section of Cardiovascular Medicine, Department of Medicine, Yale School of Medicine, New Haven, CT, 6Medtronic Inc, Minneapolis, MN, 7Division of Epidemiology, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, 8Division of Cardiology, Department of Medicine, University of Colorado, Aurora, CO, 9Department of Health Care Policy, Harvard Medical School, 10Department of Biostatistics, Harvard TH Chan School of Public Health, Boston, MA, USA; 11Discipline of Medicine, University of Adelaide, Adelaide, SA, Australia; 12Department of Clinical Informatics, California Pacific Medical Center, San Francisco, CA, USA Background: Machine learning methods may complement traditional analytic methods for medical device surveillance.Methods and results: Using data from the National Cardiovascular Data Registry for implantable cardioverter–defibrillators (ICDs linked to Medicare administrative claims for longitudinal follow-up, we applied three statistical approaches to safety-signal detection for commonly used dual-chamber ICDs that used two propensity score (PS models: one specified by subject-matter experts (PS-SME, and the other one by machine learning-based selection (PS-ML. The first approach used PS-SME and cumulative incidence (time-to-event, the second approach used PS-SME and cumulative risk (Data Extraction and

  4. Environmental Pricing: Studies in Policy Choices and Interactions

    DEFF Research Database (Denmark)

    areas of current practice that must be addressed. Empirical studies of policy strategies are discussed to illustrate the extent to which current climate change policy is integrated against the proposed successful policy combinations that are presented in this insightful book. Environmental pricing......Environmental taxes can be efficient tools for successful environmental policy. Their use, however, has been limited in many countries. This thoughtful book explores the scope of environmental pricing and examines a variety of national experiences in environmental policy integration, to identify...

  5. Radon diffusion chamber

    International Nuclear Information System (INIS)

    Pretzsch, G.; Boerner, E.; Lehmann, R.; Sarenio, O.

    1986-01-01

    The invention relates to the detection of radioactive gases emitting alpha particles like radon, thoron and their alpha-decaying daughters by means of a diffusion chamber with a passive detector, preferably with a solid state track detector. In the chamber above and towards the detector there is a single metallized electret with negative polarity. The distance between electret and detector corresponds to the range of the alpha particles of radon daughters in air at the most. The electret collects the positively charged daughters and functions as surface source. The electret increases the sensitivity by the factor 4

  6. The Honeycomb Strip Chamber

    International Nuclear Information System (INIS)

    Graaf, Harry van der; Buskens, Joop; Rewiersma, Paul; Koenig, Adriaan; Wijnen, Thei

    1991-06-01

    The Honeycomb Strip Chamber (HSC) is a new position sensitive detector. It consists of a stack of folded foils, forming a rigid honeycomb structure. In the centre of each hexagonal cell a wire is strung. Conducting strips on the foils, perpendicular to the wires, pick up the induced avalanche charge. Test results of a prototype show that processing the signals form three adjacent strips nearest to the track gives a spatial resolution better than 64 μm for perpendicular incident tracks. The chamber performance is only slightly affected by a magnetic field. (author). 25 refs.; 21 figs

  7. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1982-01-01

    An ionization smoke detector employs a single radiation source in a construction comprising at least two chambers with a center or node electrode. The radioactive source is associated with this central electrode, and its positioning may be adjusted relative to the electrode to alter the proportion of the source that protrudes into each chamber. The source may also be mounted in the plane of the central electrode, and positioned relative to the center of the electrode. The central electrode or source may be made tiltable relative to the body of the detector

  8. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  10. The Effects of an Environmental Studies Course on Selected Variables Related To Environmentally Responsible Behavior.

    Science.gov (United States)

    Smith-Sebasto, N. J.

    1995-01-01

    Reports that students completing an environmental studies course displayed significant gains when compared with students not completing such a course. These gains were made in acquiring a more internally-oriented locus of control of reinforcement for environmentally responsible behavior, a higher perception of their knowledge of and skill in using…

  11. The relationship between environmental lead and blood lead in children : a study in environmental epidemiology

    NARCIS (Netherlands)

    Brunekreef, B.

    1985-01-01

    This study deals with the relationship between environmental lead and blood lead in children.
    Chapter 1 provides a summary of the environmental health aspects of lead. The occurrence of lead in the environment and in man is described; children are discussed as a population at

  12. Preliminary Study on a Cylindrical Ambient Dose-equivalent Chamber%圆柱形周围剂量当量电离室的初步研究

    Institute of Scientific and Technical Information of China (English)

    李德红; 杨健; 邬蒙蒙; 李兴东; 杨元第

    2013-01-01

    根据国际辐射单位和测量委员会(ICRU)报告中对环境监测中新的实用辐射量定义,对一种圆柱形周围剂量当量电离室进行了初步研究.结果表明在正常工作条件下,收集极的材料和尺寸对于能量响应的影响并不明显;铝质电离室的能量响应特性好于有机玻璃的电离室.可以考虑同时采用有机玻璃和铝作为制作电离室的材料,通过理论计算并优化几何尺寸得到较好的能量响应曲线.%According to definitions of the new operational radiation quantities for area monitoring recommended by the International Commission on Radiation Units and Measurements (ICRU) report,a cylindrical ambient dose equivalent ionization chamber is designed and preliminary studied.The results show that the effect by the material and the size of the collector to the energy response is not obvious,energy response characteristic of the aluminum ionization chamber is better than that of the plexiglass.Through the theoretical calculation and geometry optimization,the cylindrical ambient dose equivalent ionization chamber made from ptexiglass as a shell and lined with an appropriate thickness of the aluminum layer will get a better energy response curve.

  13. Characterization of a tubular flow chamber for studying platelet interaction with biologic and prosthetic materials: deposition of indium 111-labeled platelets on collagen, subendothelium, and expanded polytetrafluoroethylene

    International Nuclear Information System (INIS)

    Badimon, L.; Turitto, V.; Rosemark, J.A.; Badimon, J.J.; Fuster, V.

    1987-01-01

    A plastic (Plexiglas) chamber for evaluating platelet deposition under controlled hemodynamic conditions has been developed. The perfusion chamber has been designed to retain the cylindrical shape typical of the vasculature, to be flexible enough to accept a variety of biologic and prosthetic materials, and to simulate a broad range of physiologic flow conditions in either an ex vivo or in vitro perfusion system. Three type of surfaces were exposed to blood flowing directly from the carotid artery of a heparinized pig through the perfusion chamber: de-endothelialized pig aorta, collagen strips from rabbit Achilles tendon, and an expanded polytetrafluoroethylene material (Gore-Tex). Platelets, previously radiolabeled with indium 111 and injected into the animal, were quantified on the material surface, and the total number of deposited platelets determined for a range of blood flow rates (5 to 40 ml/min) and exposure times (0.5 to 20 minutes). The deposition rates were correlated with theory for describing the mass transport of platelets to the test surface. At the wall shear rates investigated (105 to 850 sec-1), the deposition of platelets on subendothelium was strongly dependent on the local flow conditions. Values of deposition on Gore-Tex obtained at similar flow conditions (105 to 425 sec-1) were reduced compared with that observed on subendothelium and showed a markedly weaker dependence on the shear rate. In contrast, deposition of platelets on collagen was more than an order of magnitude greater than on subendothelium and showed a dependence on flow only at the lowest flow rate studied (10 ml/min). The results indicate that collagen is much more reactive than subendothelium and Gore-Tex with respect to the growth and stability of platelet aggregates and moreover suggest that flow mechanisms for depositing platelets on various surface may be substantially different

  14. Characterization of a tubular flow chamber for studying platelet interaction with biologic and prosthetic materials: deposition of indium 111-labeled platelets on collagen, subendothelium, and expanded polytetrafluoroethylene

    Energy Technology Data Exchange (ETDEWEB)

    Badimon, L.; Turitto, V.; Rosemark, J.A.; Badimon, J.J.; Fuster, V.

    1987-12-01

    A plastic (Plexiglas) chamber for evaluating platelet deposition under controlled hemodynamic conditions has been developed. The perfusion chamber has been designed to retain the cylindrical shape typical of the vasculature, to be flexible enough to accept a variety of biologic and prosthetic materials, and to simulate a broad range of physiologic flow conditions in either an ex vivo or in vitro perfusion system. Three type of surfaces were exposed to blood flowing directly from the carotid artery of a heparinized pig through the perfusion chamber: de-endothelialized pig aorta, collagen strips from rabbit Achilles tendon, and an expanded polytetrafluoroethylene material (Gore-Tex). Platelets, previously radiolabeled with indium 111 and injected into the animal, were quantified on the material surface, and the total number of deposited platelets determined for a range of blood flow rates (5 to 40 ml/min) and exposure times (0.5 to 20 minutes). The deposition rates were correlated with theory for describing the mass transport of platelets to the test surface. At the wall shear rates investigated (105 to 850 sec-1), the deposition of platelets on subendothelium was strongly dependent on the local flow conditions. Values of deposition on Gore-Tex obtained at similar flow conditions (105 to 425 sec-1) were reduced compared with that observed on subendothelium and showed a markedly weaker dependence on the shear rate. In contrast, deposition of platelets on collagen was more than an order of magnitude greater than on subendothelium and showed a dependence on flow only at the lowest flow rate studied (10 ml/min). The results indicate that collagen is much more reactive than subendothelium and Gore-Tex with respect to the growth and stability of platelet aggregates and moreover suggest that flow mechanisms for depositing platelets on various surface may be substantially different.

  15. Calibration of the ATLAS precision muon chambers and study of the decay {tau} {yields} {mu}{mu}{mu} at the large hadron collider

    Energy Technology Data Exchange (ETDEWEB)

    Loeben, Joerg Horst Jochen von

    2010-07-07

    The Large Hadron Collider (LHC) is designed to collide protons at centre-of-mass energies of up to 14 TeV. One of the two general purpose experiments at the LHC is ATLAS, built to probe a broad spectrum of physics processes of the Standard Model of particle physics and beyond. ATLAS is equipped with a muon spectrometer comprising three superconducting air-core toroid magnets and 1150 precision drift tube (MDT) chambers measuring muon trajectories with better than 50 {mu}m position resolution. The accuracy of the space-to-drift-time relationships of the MDT chambers is one of the main contributions to the momentum resolution. In this thesis, an improved method for the calibration of the precision drift tube chambers in magnetic fields has been developed and tested using curved muon track segments. An accuracy of the drift distance measurement of better than 20 {mu}m is achieved leading to negligible deterioration of the muon momentum resolution. The second part of this work is dedicated to the study of the lepton flavour violating decay {tau}{yields}{mu}{mu}{mu}. Lepton flavour violation is predicted by almost every extension of the Standard Model. About 10{sup 12}{tau} leptons are produced per year at an instantaneous luminosity of 10{sup 33} cm{sup -2}s{sup -1} and a centre-of-mass energy of 14 TeV. Simulated data samples have been used to evaluate the sensitivity of the ATLAS experiment for {tau}{yields}{mu}{mu}{mu} decays with an integrated luminosity of 10 fb{sup -1}. Taking theoretical and experimental systematic uncertainties into account an upper limit on the signal branching ratio of B({tau}{yields}{mu}{mu}{mu}) <5.9 x 10{sup -7} at 90% confidence level is achievable. This result represents the first estimation in ATLAS. (orig.)

  16. Study of Interaction of Low-Energy Antiprotons with H$^{2}$,He$^{3}$,He$^{4}$,Ne-Nuclei Using a Streamer Chamber in Magnetic Field

    CERN Multimedia

    2002-01-01

    The aim of this experiment is the systematic study of the interaction between low-energy antiprotons and the H|2,~He|3,~He|4,~Ne-nuclei using a self shunted streamer chamber in a magnetic field exposed to the antiproton beam of the LEAR facility. The properties of the self shunted streamer chamber, which allows the use of the filling gas (hydrogen, helium, neon at a pressure of l~atm) as a target, permit to carry out experiments also in the very low-energy region. \\\\ \\\\ The experimental apparatus is suitable for a large programme of measurements. We plan to measure the @*H|2 cross section and the spectator momentum distributions at @* momenta lower than 250~MeV/c, where data are lacking. It is interesting to study for the first time the @*He|3 and @*He|4 interactions measuring the cross sections and the emitted particle distributions. Among other things the knowledge of the branching ratio of the @*He|4 annihilation channels clarifies some open cosmological questions. The study of the process of nuclear absor...

  17. The impact of insonation angle on four-chamber view image quality: an observational study on 2866 routine scans.

    Science.gov (United States)

    Jaudi, Suha; Fries, Nicolas; Tezenas du Montcel, Sophie; Dommergues, Marc

    2015-04-01

    To determine insonation angles achieved in routine screening practice and their impact on image quality. Prospective cross-sectional observational survey of 2866 four-chamber views produced by 287 senor ultrasonographers, from unselected routine second-trimester screening scans. Images were scored from 0 to 5 according to whether two atria, two ventricles, the heart crux, the apex, and the descending aorta were seen. Images were considered adequate if two atria, two ventricles, and the heart crux were seen. The insonation angle was classified as apical, basal, or lateral according to the orientation of the fetal heart to the ultrasound beam. There were 1612 (56.3%) apical, 869 (30.3%) basal, and 385 (13.4%) lateral views. The mean score and the rate of adequate images were significantly greater in the apical group (4.56 and 81.8%) than in the basal group (4.19 and 71.1 %) and were significantly greater in the basal group than in the lateral one (3.6 and 30.9%), p John Wiley & Sons, Ltd. © 2015 John Wiley & Sons, Ltd.

  18. Comparison among different CT ionization chambers

    International Nuclear Information System (INIS)

    Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E.

    2015-01-01

    The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)

  19. Studies of environmental compatability. Umweltbundesamt - Texte

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    The evaluation of the methodical quality of the examples by means of a verification pattern had the result that approaches using quantitative methods - as for example the value in use analysis obtained better results: The representation of the state of the environment and of possible impairments of the environment, which had bejudged, achieved a higher degree of representativeness and completeness. Furthermore the concreteness of the used criteria for the description of the repercussions of a plan and the possibility to quantify same had to be judged more favourable. It must critically be remarked that by using quantitative methods difficulties may appear if impairments of the environment overlap or if there are correlations between the media respectively if there are non-linear repercussions of measures causing environmental damages. The present level of research should be developed to a strenghtened inclusion of complex and dynamic correlations of effects. More exacting investigations concerning environmental compatability are on the long term integrated in administrative procedures only at few authorities. With the demand for an extension of environmental compatability assessment to all steps of planning and procedure for the realization of a plan an early and more intensive participation of the public should be connected.

  20. A study of environmental polluting factors by neutron activation method

    International Nuclear Information System (INIS)

    Paunoiu, C.; Doca, C.

    2004-01-01

    The paper presents: a) some importance factors of the environmental pollution; b) the theoretical aspects of the Neutron Activation Analysis (NAA) used in the study of the environmental pollution; c) the NAA specific hardware and software facilities existing at the Institute for Nuclear Research; d) a direct application of the NAA method in the study of the environmental pollution for Pitesti city by the analysis of some ground and vegetation samples; e) results and conclusions. (authors)

  1. A data base of crop nutrient use, water use, and carbon dioxide exchange in a 2O square meter growth chamber: I. Wheat as a case study

    Science.gov (United States)

    Wheeler, R. M.; Berry, W. L.; Mackowiak, C.; Corey, K. A.; Sager, J. C.; Heeb, M. M.; Knott, W. M.

    1993-01-01

    A data set is given describing the daily nutrient uptake, gas exchange, environmental conditions, and carbon (C), and nutrient partitioning at harvest for the entire canopy and root system of a wheat crop (Triticum aestivum, cv. Yecora Rojo). The data were obtained from a 20 m2 stand of wheat plants grown from planting to maturity in a closed, controlled environment, and include daily nutrient uptake [macronutrients, nitrogen (N), phosphorus (P), potassium (K), calcium (Ca), magnesium (Mg), and sulfur (S); and micronutrients, iron (Fe), boron (B), manganese (Mn), zinc (Zn), copper (Cu), and molybdenum (Mo)], canopy carbon dioxide (CO2) exchange rates, and transpiration. Environmental factors such as relative humidity, air temperature, nutrient solution temperature, pH and electrical conductivity, and photoperiod were controlled in the chamber to specific set points. A detailed description of biomass yield for each of the 64 plant growth trays comprising the 20 m2 of growth area is also provided, and includes dry weights of grain, straw, chaff, and roots, along with the concentration of nutrients in different plant tissues and the percent carbohydrate, fat, and protein. To our knowledge, this information represents one of the most extensive data sets available for a canopy of wheat grown from seed to maturity under controlled environmental and nutritional conditions, and thus may provide useful information for model development and validation. A methods section is included to qualify any assumptions that might be required for the use of the data in plant growth models, along with a daily event calendar indicating when adjustments in set points and occasional equipment or sensor failures occurred.

  2. A Data Base of Crop Nutrient Use, Water Use, and Carbon Dioxide Exchange in a 20 Square Meter Growth Chamber. Part 1; Wheat as a Case Study

    Science.gov (United States)

    Wheeler, Raymond M.; Berry, Wade L.; Mackowiak, Cheryl; Corey, Kenneth A.; Sager, John C.; Heeb, Margaret M.; Knott, William M.

    1993-01-01

    A data set is given describing the daily nutrient uptake, gas exchange, environmental conditions, and carbon (C), and nutrient partitioning at harvest for the entire canopy and root system of a wheat crop (Triticum aestivum, cv. Yecora Rojo). The data were obtained from a 20 sq m stand of wheat plants grown from planting to maturity in a closed, controlled environment, and include daily nutrient uptake [macronutrients, nitrogen (N), phosphorus (P), potassium (K), calcium (Ca), magnesium (Mg), and sulfur (S); and micronutrients, iron (Fe), boron (B), manganese (Mn), zinc (Zn), copper (Cu), and molybdenum (Mo)], canopy carbon dioxide (CO2) exchange rates, and transpiration. Environmental factors such as relative humidity, air temperature, nutrient solution temperature, pH and electrical conductivity, and photoperiod were controlled in the chamber to specific set points. A detailed description of biomass yield for each of the 64 plant growth trays comprising the 20 sq m of growth area is also provided, and includes dry weights of grain, straw, chaff, and roots, along with the concentration of nutrients in different plant tissues and the percent carbohydrate, fat, and protein. To our knowledge, this information represents one of the most extensive data sets available for a canopy of wheat grown from seed to maturity under controlled environmental and nutritional conditions, and thus may provide useful information for model development and validation. A methods section is included to qualify any assumptions that might he required for the use of the data in plant growth models, along with a daily event calendar indicating when adjustments in set points and occasional equipment or sensor failures occurred.

  3. Design, construction, prototype tests and performance of a vertex chamber for the MAC detector

    International Nuclear Information System (INIS)

    Ash, W.W.; Band, H.R.; Bloom, E.D.; Bosman, M.; Camporesi, T.; Chadwick, G.B.; Delfino, M.C.; De Sangro, R.; Ford, W.T.; Gettner, M.W.; Goderre, G.P.; Godfrey, G.L.; Groom, D.E.; Hurst, R.B.; Johnson, J.R.; Lau, K.H.; Lavine, T.L.; Leedy, R.E.; Lippi, I.; Maruyama, T.; Messner, R.L.; Moromisato, J.H.; Moss, L.J.; Muller, F.; Nelson, H.N.; Peruzzi, I.; Piccolo, M.; Prepost, R.; Pyrlik, J.; Qi, N.; Read, A.L. Jr.; Ritson, D.M.; Rosenberg, L.J.; Shambroom, W.D.; Sleeman, J.C.; Smith, J.G.; Venuti, J.P.; Verdini, P.G.; Goeler, E. von; Wald, H.B.; Weinstein, R.; Wiser, D.E.; Zdarko, R.W.; Istituto Nazionale di Fisica Nucleare, Frascati; Houston Univ., TX; Northeastern Univ., Boston, MA; Stanford Univ., CA; Stanford Linear Accelerator Center, CA; Utah Univ., Salt Lake City; Wisconsin Univ., Madison

    1987-01-01

    The design considerations, construction techniques, prototype tests and performance characteristics of a pressurized drift chamber used in the MAC detector at PEP are described. The chamber consists of 324 aluminized mylar tubes of 6.9 mm diameter with wall thickness of 100 μm. With appropriate shielding it operates successfully at 4.6 cm from the beam line. It was simple to construct and was configured to permit any malfunctioning tubes to be remotely disconnected without affecting operation. The chamber operated without problems for two years in the PEP environmental with a gas mixture of 49.5% argon, 49.5% CO 2 , 1% CH 4 , at 4 atm absolute pressure. The mean spatial resolution averaged over all tubes was 45 μm. The time to distance relation for this gas mixture, along with the geometric positioning of individual wires relative to the central tracking chamber, was obtained with data from Bhabha scattering events. We also describe resolution studies performed with a prototype chamber in a SLAC test beam. A wide range of gases, gas pressures, and electronic parameters were explored. These studies proved that resolutions in the 10-50 μm range were possible. Our experience demonstrates that chambers of this type provide high precision tracking and are particularly suited for operation in regions with difficult physical access and/or high ambient radiation levels. (orig.)

  4. Randomized placebo controlled blinded study to assess valsartan efficacy in preventing left ventricle remodeling in patients with dual chamber pacemaker--Rationale and design of the trial.

    Science.gov (United States)

    Tomasik, Andrzej; Jacheć, Wojciech; Wojciechowska, Celina; Kawecki, Damian; Białkowska, Beata; Romuk, Ewa; Gabrysiak, Artur; Birkner, Ewa; Kalarus, Zbigniew; Nowalany-Kozielska, Ewa

    2015-05-01

    Dual chamber pacing is known to have detrimental effect on cardiac performance and heart failure occurring eventually is associated with increased mortality. Experimental studies of pacing in dogs have shown contractile dyssynchrony leading to diffuse alterations in extracellular matrix. In parallel, studies on experimental ischemia/reperfusion injury have shown efficacy of valsartan to inhibit activity of matrix metalloproteinase-9, to increase the activity of tissue inhibitor of matrix metalloproteinase-3 and preserve global contractility and left ventricle ejection fraction. To present rationale and design of randomized blinded trial aimed to assess whether 12 month long administration of valsartan will prevent left ventricle remodeling in patients with preserved left ventricle ejection fraction (LVEF ≥ 40%) and first implantation of dual chamber pacemaker. A total of 100 eligible patients will be randomized into three parallel arms: placebo, valsartan 80 mg/daily and valsartan 160 mg/daily added to previously used drugs. The primary endpoint will be assessment of valsartan efficacy to prevent left ventricle remodeling during 12 month follow-up. We assess patients' functional capacity, blood plasma activity of matrix metalloproteinases and their tissue inhibitors, NT-proBNP, tumor necrosis factor alpha, and Troponin T. Left ventricle function and remodeling is assessed echocardiographically: M-mode, B-mode, tissue Doppler imaging. If valsartan proves effective, it will be an attractive measure to improve long term prognosis in aging population and increasing number of pacemaker recipients. ClinicalTrials.org (NCT01805804). Copyright © 2015 Elsevier Inc. All rights reserved.

  5. LEP vacuum chamber, prototype

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Final prototype for the LEP vacuum chamber, see 8305170 for more details. Here we see the strips of the NEG pump, providing "distributed pumping". The strips are made from a Zr-Ti-Fe alloy. By passing an electrical current, they were heated to 700 deg C.

  6. Heavy liquid bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The CERN Heavy liquid bubble chamber being installed in the north experimental hall at the PS. On the left, the 1180 litre body; in the centre the magnet, which can produce a field of 26 800 gauss; on the right the expansion mechanism.

  7. Drift chamber detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez Laso, L.

    1989-01-01

    A review of High Energy Physics detectors based on drift chambers is presented. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysied, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author)

  8. Drift Chambers detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez laso, L.

    1989-01-01

    We present here a review of High Energy Physics detectors based on drift chambers. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysed, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author) 115 refs

  9. OPAL Muon Chamber

    CERN Multimedia

    OPAL was one of the 4 experiments installed at the LEP particle accelerator from 1989 to 2000. This is a slice of the outermost layer of OPAL : the muon chambers. This outside layer detects particles which are not stopped by the previous layers. These are mostly muons.

  10. Improvements in ionization chambers

    International Nuclear Information System (INIS)

    Whetten, N.R.; Zubal, C.

    1980-01-01

    A method of reducing mechanical vibrations transmitted to the parallel plate electrodes of ionization chamber x-ray detectors, commonly used in computerized x-ray axial tomography systems, is described. The metal plate cathodes and anodes are mounted in the ionizable gas on dielectric sheet insulators consisting of a composite of silicone resin and glass fibres. (UK)

  11. LEP Vacuum Chamber

    CERN Multimedia

    1983-01-01

    This is a cut-out of a LEP vacuum chamber for dipole magnets showing the beam channel and the pumping channel with the getter (NEG) strip and its insulating supports. A water pipe connected to the cooling channel can also be seen at the back.The lead radiation shield lining is also shown. See also 8305563X.

  12. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  13. Ion chamber instrument

    International Nuclear Information System (INIS)

    Stephan, D.H.

    1975-01-01

    An electrical ionization chamber is described having a self-supporting wall of cellular material which is of uniform areal density and formed of material, such as foamed polystyrene, having an average effective atomic number between about 4 and about 9, and easily replaceable when on the instrument. (auth)

  14. Review of straw chambers

    International Nuclear Information System (INIS)

    Toki, W.H.

    1990-03-01

    This is a review of straw chambers used in the HRS, MAC, Mark III, CLEO, AMY, and TPC e + e - experiments. The straws are 6--8 mm in diameter, operate at 1--4 atmospheres and obtain resolutions of 45--100 microns. The designs and constructions are summarized and possible improvements discussed

  15. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  16. Peculiarities occurrence and microstrip gas chambers studied through experiment WA97; La production d`etrangete et les chambres gazeuses a micropistes dans le cadre de l`experience WA97

    Energy Technology Data Exchange (ETDEWEB)

    Kachelhoffer, T.

    1995-04-01

    This paper presents the studies on development of a Monte-Carlo type generator used for inclusive production of odd baryons and antibaryons through proton- proton and proton- nucleus collisions. Experiment WA97 consisted in designing simulation software for MSGCs (Micro-strips Gas Chambers) as well as the redefining of particle paths with the help of these chambers. This work made it possible to design the MSGC detector for experiment WA97. (TEC). 71 refs., 88 figs.

  17. A comparative study between clinical grading of anterior chamber flare and flare reading using the Kowa laser flare meter.

    Science.gov (United States)

    Konstantopoulou, Kallirroi; Del'Omo, Roberto; Morley, Anne M; Karagiannis, Dimitris; Bunce, Catey; Pavesio, Carlos

    2015-10-01

    To assess the accuracy of standard clinical grading of aqueous flare in uveitis according to the Standardization of Uveitis Nomenclature consensus, and compare the results with the readings of the laser flare meter, Kowa 500. Two examiners clinically graded the flare in 110 eyes. The flare was then measured using the Kowa laser flare meter. Twenty-nine eyes were graded as anterior chamber flare +2; for 18 of these, the clinicians were in agreement, the rest differed by the order of one grade. The range of the laser flare meter for these eyes was 5.2-899.1 photons/ms. The median value was 41.4. Seventy-four eyes were graded with flare +1. Agreement was established in 51 of these eyes. Disagreement for the rest was again by the order of 1, and the flare meter range was 1.1-169.9 photons/ms, median value 18.4. For the clinical measure of flare 0, the clinicians disagreed on three out of five eyes. The flare meter readings ranged from 2.5 to 14.1 photons/ms, median value 9.9. Only two eyes were graded with flare +3 and there was one step disagreement on both of them. We found little evidence of association between the flare readings and intraocular pressure or age. Our findings suggest that clinical evaluation of aqueous flare is subjective. Compared with the Kowa laser flare meter's numeric readings, the discrepancies observed indicate that clinical grading is an approximate science. The laser flare meter provides an accurate, reproducible, non-invasive assessment of aqueous flare that can prove valuable in research and clinical decisions.

  18. Environmental Regulation and Food Safety: Studies of Protection ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Environmental Regulation and Food Safety: Studies of Protection and Protectionism. Book cover Environmental Regulation and Food Safety: Studies of Protection and Protectionism. Directeur(s) : Veena Jha. Maison(s) d'édition : Edward Elgar, IDRC. 1 janvier 2006. ISBN : 184542512X. 250 pages. e-ISBN : 155250185X.

  19. Environmental ethics and wilderness management: an empirical study

    Science.gov (United States)

    William A. Valliere; Robert E. Manning

    1995-01-01

    The underlying hypothesis of this study is that environmental ethics influence public attitudes toward wilderness management. To study this hypothesis, environmental ethics were defined, categorized, and measured empirically. Additionally, attitudes toward selected wilderness management issues were measured. Associations were found between beliefs in selected...

  20. Cloud chamber photographs of the cosmic radiation

    CERN Document Server

    Rochester, George Dixon

    1952-01-01

    Cloud Chamber Photographs of the Cosmic Radiation focuses on cloud chamber and photographic emulsion wherein the tracks of individual subatomic particles of high energy are studied. The publication first offers information on the technical features of operation and electrons and cascade showers. Discussions focus on the relationship in time and space of counter-controlled tracks; techniques of internal control of the cloud chamber; cascade processes with artificially-produced electrons and photons; and nuclear interaction associated with an extensive shower. The manuscript then elaborates on