WorldWideScience

Sample records for environmental analytical methods

  1. Quantifying the measurement uncertainty of results from environmental analytical methods.

    Science.gov (United States)

    Moser, J; Wegscheider, W; Sperka-Gottlieb, C

    2001-07-01

    The Eurachem-CITAC Guide Quantifying Uncertainty in Analytical Measurement was put into practice in a public laboratory devoted to environmental analytical measurements. In doing so due regard was given to the provisions of ISO 17025 and an attempt was made to base the entire estimation of measurement uncertainty on available data from the literature or from previously performed validation studies. Most environmental analytical procedures laid down in national or international standards are the result of cooperative efforts and put into effect as part of a compromise between all parties involved, public and private, that also encompasses environmental standards and statutory limits. Central to many procedures is the focus on the measurement of environmental effects rather than on individual chemical species. In this situation it is particularly important to understand the measurement process well enough to produce a realistic uncertainty statement. Environmental analytical methods will be examined as far as necessary, but reference will also be made to analytical methods in general and to physical measurement methods where appropriate. This paper describes ways and means of quantifying uncertainty for frequently practised methods of environmental analysis. It will be shown that operationally defined measurands are no obstacle to the estimation process as described in the Eurachem/CITAC Guide if it is accepted that the dominating component of uncertainty comes from the actual practice of the method as a reproducibility standard deviation.

  2. Nuclear and nuclear related analytical methods applied in environmental research

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Gheboianu, Anca; Bancuta, Iulian; Cimpoca, G. V; Stihi, Claudia; Radulescu, Cristiana; Oros Calin; Frontasyeva, Marina; Petre, Marian; Dulama, Ioana; Vlaicu, G.

    2010-01-01

    Nuclear Analytical Methods can be used for research activities on environmental studies like water quality assessment, pesticide residues, global climatic change (transboundary), pollution and remediation. Heavy metal pollution is a problem associated with areas of intensive industrial activity. In this work the moss bio monitoring technique was employed to study the atmospheric deposition in Dambovita County Romania. Also, there were used complementary nuclear and atomic analytical methods: Neutron Activation Analysis (NAA), Atomic Absorption Spectrometry (AAS) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). These high sensitivity analysis methods were used to determine the chemical composition of some samples of mosses placed in different areas with different pollution industrial sources. The concentrations of Cr, Fe, Mn, Ni and Zn were determined. The concentration of Fe from the same samples was determined using all these methods and we obtained a very good agreement, in statistical limits, which demonstrate the capability of these analytical methods to be applied on a large spectrum of environmental samples with the same results. (authors)

  3. Determination of 237Np in environmental and nuclear samples: A review of the analytical method

    International Nuclear Information System (INIS)

    Thakur, P.; Mulholland, G.P.

    2012-01-01

    A number of analytical methods has been developed and used for the determination of neptunium in environmental and nuclear fuel samples using alpha, ICP–MS spectrometry, and other analytical techniques. This review summarizes and discusses development of the radiochemical procedures for separation of neptunium (Np), since the beginning of the nuclear industry, followed by a more detailed discussion on recent trends in the separation of neptunium. This article also highlights the progress in analytical methods and issues associated with the determination of neptunium in environmental samples. - Highlights: ► Determination of Np in environmental and nuclear samples is reviewed. ► Various analytical methods used for the determination of Np are listed. ► Progress and issues associated with the determination of Np are discussed.

  4. Characterization of carbon nanotubes and analytical methods for their determination in environmental and biological samples: A review

    Energy Technology Data Exchange (ETDEWEB)

    Herrero-Latorre, C., E-mail: carlos.herrero@usc.es; Álvarez-Méndez, J.; Barciela-García, J.; García-Martín, S.; Peña-Crecente, R.M.

    2015-01-01

    Highlights: • Analytical techniques for characterization of CNTs: classification, description and examples. • Determination methods for CNTs in biological and environmental samples. • Future trends and perspectives for characterization and determination of CNTs. - Abstract: In the present paper, a critical overview of the most commonly used techniques for the characterization and the determination of carbon nanotubes (CNTs) is given on the basis of 170 references (2000–2014). The analytical techniques used for CNT characterization (including microscopic and diffraction, spectroscopic, thermal and separation techniques) are classified, described, and illustrated with applied examples. Furthermore, the performance of sampling procedures as well as the available methods for the determination of CNTs in real biological and environmental samples are reviewed and discussed according to their analytical characteristics. In addition, future trends and perspectives in this field of work are critically presented.

  5. Environmental vulnerability assessment using Grey Analytic Hierarchy Process based model

    International Nuclear Information System (INIS)

    Sahoo, Satiprasad; Dhar, Anirban; Kar, Amlanjyoti

    2016-01-01

    Environmental management of an area describes a policy for its systematic and sustainable environmental protection. In the present study, regional environmental vulnerability assessment in Hirakud command area of Odisha, India is envisaged based on Grey Analytic Hierarchy Process method (Grey–AHP) using integrated remote sensing (RS) and geographic information system (GIS) techniques. Grey–AHP combines the advantages of classical analytic hierarchy process (AHP) and grey clustering method for accurate estimation of weight coefficients. It is a new method for environmental vulnerability assessment. Environmental vulnerability index (EVI) uses natural, environmental and human impact related factors, e.g., soil, geology, elevation, slope, rainfall, temperature, wind speed, normalized difference vegetation index, drainage density, crop intensity, agricultural DRASTIC value, population density and road density. EVI map has been classified into four environmental vulnerability zones (EVZs) namely: ‘low’, ‘moderate’ ‘high’, and ‘extreme’ encompassing 17.87%, 44.44%, 27.81% and 9.88% of the study area, respectively. EVI map indicates that the northern part of the study area is more vulnerable from an environmental point of view. EVI map shows close correlation with elevation. Effectiveness of the zone classification is evaluated by using grey clustering method. General effectiveness is in between “better” and “common classes”. This analysis demonstrates the potential applicability of the methodology. - Highlights: • Environmental vulnerability zone identification based on Grey Analytic Hierarchy Process (AHP) • The effectiveness evaluation by means of a grey clustering method with support from AHP • Use of grey approach eliminates the excessive dependency on the experience of experts.

  6. Environmental vulnerability assessment using Grey Analytic Hierarchy Process based model

    Energy Technology Data Exchange (ETDEWEB)

    Sahoo, Satiprasad [School of Water Resources, Indian Institute of Technology Kharagpur (India); Dhar, Anirban, E-mail: anirban.dhar@gmail.com [Department of Civil Engineering, Indian Institute of Technology Kharagpur (India); Kar, Amlanjyoti [Central Ground Water Board, Bhujal Bhawan, Faridabad, Haryana (India)

    2016-01-15

    Environmental management of an area describes a policy for its systematic and sustainable environmental protection. In the present study, regional environmental vulnerability assessment in Hirakud command area of Odisha, India is envisaged based on Grey Analytic Hierarchy Process method (Grey–AHP) using integrated remote sensing (RS) and geographic information system (GIS) techniques. Grey–AHP combines the advantages of classical analytic hierarchy process (AHP) and grey clustering method for accurate estimation of weight coefficients. It is a new method for environmental vulnerability assessment. Environmental vulnerability index (EVI) uses natural, environmental and human impact related factors, e.g., soil, geology, elevation, slope, rainfall, temperature, wind speed, normalized difference vegetation index, drainage density, crop intensity, agricultural DRASTIC value, population density and road density. EVI map has been classified into four environmental vulnerability zones (EVZs) namely: ‘low’, ‘moderate’ ‘high’, and ‘extreme’ encompassing 17.87%, 44.44%, 27.81% and 9.88% of the study area, respectively. EVI map indicates that the northern part of the study area is more vulnerable from an environmental point of view. EVI map shows close correlation with elevation. Effectiveness of the zone classification is evaluated by using grey clustering method. General effectiveness is in between “better” and “common classes”. This analysis demonstrates the potential applicability of the methodology. - Highlights: • Environmental vulnerability zone identification based on Grey Analytic Hierarchy Process (AHP) • The effectiveness evaluation by means of a grey clustering method with support from AHP • Use of grey approach eliminates the excessive dependency on the experience of experts.

  7. Supercritical fluid analytical methods

    International Nuclear Information System (INIS)

    Smith, R.D.; Kalinoski, H.T.; Wright, B.W.; Udseth, H.R.

    1988-01-01

    Supercritical fluids are providing the basis for new and improved methods across a range of analytical technologies. New methods are being developed to allow the detection and measurement of compounds that are incompatible with conventional analytical methodologies. Characterization of process and effluent streams for synfuel plants requires instruments capable of detecting and measuring high-molecular-weight compounds, polar compounds, or other materials that are generally difficult to analyze. The purpose of this program is to develop and apply new supercritical fluid techniques for extraction, separation, and analysis. These new technologies will be applied to previously intractable synfuel process materials and to complex mixtures resulting from their interaction with environmental and biological systems

  8. Hanford environmental analytical methods: Methods as of March 1990

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Daniel, J.L.

    1993-05-01

    This paper from the analytical laboratories at Hanford describes the method used to measure pH of single-shell tank core samples. Sludge or solid samples are mixed with deionized water. The pH electrode used combines both a sensor and reference electrode in one unit. The meter amplifies the input signal from the electrode and displays the pH visually

  9. Analytical quality control in environmental analysis - Recent results and future trends of the IAEA's analytical quality control programme

    Energy Technology Data Exchange (ETDEWEB)

    Suschny, O; Heinonen, J

    1973-12-01

    The significance of analytical results depends critically on the degree of their reliability, an assessment of this reliability is indispensable if the results are to have any meaning at all. Environmental radionuclide analysis is a relatively new analytical field in which new methods are continuously being developed and into which many new laboratories have entered during the last ten to fifteen years. The scarcity of routine methods and the lack of experience of the new laboratories have made the need for the assessment of the reliability of results particularly urgent in this field. The IAEA, since 1962, has provided assistance to its member states by making available to their laboratories analytical quality control services in the form of standard samples, reference materials and the organization of analytical intercomparisons. The scope of this programme has increased over the years and now includes, in addition to environmental radionuclides, non-radioactive environmental contaminants which may be analysed by nuclear methods, materials for forensic neutron activation analysis, bioassay materials and nuclear fuel. The results obtained in recent intercomparisons demonstrate the continued need for these services. (author)

  10. Simple analytical technique for liquid scintillation counting of environmental carbon-14 using gel suspension method

    International Nuclear Information System (INIS)

    Okai, Tomio; Wakabayashi, Genichiro; Nagao, Kenjiro; Matoba, Masaru; Ohura, Hirotaka; Momoshima, Noriyuki; Kawamura, Hidehisa

    2000-01-01

    A simple analytical technique for liquid scintillation counting of environmental 14 C was developed. Commercially available gelling agent, N-lauroyl-L -glutamic -α,γ-dibutylamide, was used for the gel-formation of the samples (gel suspension method) and for the subsequent liquid scintillation counting of 14 C in the form of CaCO 3 . Our procedure for sample preparation is much simpler than that of the conventional methods and requires no special equipment. Self absorption, stability and reproducibility of gel suspension samples were investigated in order to evaluate the characteristics of the gel suspension method for 14 C activity measurement. The self absorption factor is about 70% and slightly decrease as CaCO 3 weight increase. This is considered to be mainly due to the absorption of β-rays and scintillation light by the CaCO 3 sample itself. No change of the counting rate for the gel suspension sample was observed for more than 2 years after the sample preparation. Four samples were used for checking the reproducibility of the sample preparation method. The same values were obtained for the counting rate of 24 C activity within the counting error. No change of the counting rate was observed for the 're-gelated' sample. These results show that the gel suspension method is appropriate for the 14 C activity measurement by the liquid scintillation counting method and useful for a long-term preservation of the sample for repeated measurement. The above analytical technique was applied to actual environmental samples in Fukuoka prefecture, Japan. Results obtained were comparable with those by other researchers and appear to be reasonable. Therefore, the newly developed technique is useful for the routine monitoring of environmental 14 C. (author)

  11. Development of analytical techniques for safeguards environmental samples at JAEA

    International Nuclear Information System (INIS)

    Sakurai, Satoshi; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, Chi-Gyu; Yasuda, Kenichiro; Inagawa, Jun; Suzuki, Daisuke; Iguchi, Kazunari; Kokubu, Yoko S.; Miyamoto, Yutaka; Ohzu, Akira

    2007-01-01

    JAEA has been developing, under the auspices of the Ministry of Education, Culture, Sports, Science and Technology of Japan, analytical techniques for ultra-trace amounts of nuclear materials in environmental samples in order to contribute to the strengthened safeguards system. Development of essential techniques for bulk and particle analysis, as well as screening, of the environmental swipe samples has been established as ultra-trace analytical methods of uranium and plutonium. In January 2003, JAEA was qualified, including its quality control system, as a member of the JAEA network analytical laboratories for environmental samples. Since 2004, JAEA has conducted the analysis of domestic and the IAEA samples, through which JAEA's analytical capability has been verified and improved. In parallel, advanced techniques have been developed in order to expand the applicability to the samples of various elemental composition and impurities and to improve analytical accuracy and efficiency. This paper summarizes the trace of the technical development in environmental sample analysis at JAEA, and refers to recent trends of research and development in this field. (author)

  12. Analytical Methodology for the Determination of Radium Isotopes in Environmental Samples

    International Nuclear Information System (INIS)

    2010-01-01

    Reliable, comparable and 'fit for purpose' results are an essential requirement for any decision based on analytical measurements. For the analyst, the availability of tested and validated analytical procedures is an extremely important tool for production of such analytical measurements. For maximum utility, such procedures should be comprehensive, clearly formulated, and readily available to both the analyst and the customer for reference. Since 2004, the environment programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. Measurements of radium isotopes are important for radiological and environmental protection, geochemical and geochronological investigations, hydrology, etc. The suite of isotopes creates and stimulates continuing interest in the development of new methods for determination of radium in various media. In this publication, the four most routinely used analytical methods for radium determination in biological and environmental samples, i.e. alpha spectrometry, gamma spectrometry, liquid scintillation spectrometry and mass spectrometry, are reviewed

  13. Development of analytical methods for the separation of plutonium, americium, curium and neptunium from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Salminen, S.

    2009-07-01

    In this work, separation methods have been developed for the analysis of anthropogenic transuranium elements plutonium, americium, curium and neptunium from environmental samples contaminated by global nuclear weapons testing and the Chernobyl accident. The analytical methods utilized in this study are based on extraction chromatography. Highly varying atmospheric plutonium isotope concentrations and activity ratios were found at both Kurchatov (Kazakhstan), near the former Semipalatinsk test site, and Sodankylae (Finland). The origin of plutonium is almost impossible to identify at Kurchatov, since hundreds of nuclear tests were performed at the Semipalatinsk test site. In Sodankylae, plutonium in the surface air originated from nuclear weapons testing, conducted mostly by USSR and USA before the sampling year 1963. The variation in americium, curium and neptunium concentrations was great as well in peat samples collected in southern and central Finland in 1986 immediately after the Chernobyl accident. The main source of transuranium contamination in peats was from global nuclear test fallout, although there are wide regional differences in the fraction of Chernobyl-originated activity (of the total activity) for americium, curium and neptunium. The separation methods developed in this study yielded good chemical recovery for the elements investigated and adequately pure fractions for radiometric activity determination. The extraction chromatographic methods were faster compared to older methods based on ion exchange chromatography. In addition, extraction chromatography is a more environmentally friendly separation method than ion exchange, because less acidic waste solutions are produced during the analytical procedures. (orig.)

  14. Studies on application of neutron activation analysis -Applied research on air pollution monitoring and development of analytical method of environmental samples

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Chung, Young Ju; Jeong, Eui Sik; Lee, Sang Mi; Kang, Sang Hun; Cho, Seung Yeon; Kwon, Young Sik; Chung, Sang Wuk; Lee, Kyu Sung; Chun, Ki Hong; Kim, Nak Bae; Lee, Kil Yong; Yoon, Yoon Yeol; Chun, Sang Ki.

    1997-09-01

    This research report is written for results of applied research on air pollution monitoring using instrumental neutron activation analysis. For identification and standardization of analytical method, 24 environmental samples are analyzed quantitatively, and accuracy and precision of this method are measured. Using airborne particulate matter and biomonitor chosen as environmental indicators, trace elemental concentrations of sample collected at urban and rural site monthly are determined ant then the calculation of statistics and the factor analysis are carried out for investigation of emission source. Facilities for NAA are installed in a new HANARO reactor, functional test is performed for routine operation. In addition, unified software code for NAA is developed to improve accuracy, precision and abilities of analytical processes. (author). 103 refs., 61 tabs., 19 figs

  15. Manual of selected physico-chemical analytical methods. IV

    International Nuclear Information System (INIS)

    Beran, M.; Klosova, E.; Krtil, J.; Sus, F.; Kuvik, V.; Vrbova, L.; Hamplova, M.; Lengyel, J.; Kelnar, L.; Zakouril, K.

    1990-11-01

    The Central Testing Laboratory of the Nuclear Research Institute at Rez has for a decade been participating in the development of analytical procedures and has been providing analyses of samples of different types and origin. The analytical procedures developed have been published in special journals and a number of them in the Manuals of analytical methods, in three parts. The 4th part of the Manual contains selected physico-chemical methods developed or modified by the Laboratory in the years 1986-1990 within the project ''Development of physico-chemical analytical methods''. In most cases, techniques are involved for non-nuclear applications. Some can find wider applications, especially in analyses of environmental samples. Others have been developed for specific cases of sample analyses or require special instrumentation (mass spectrometer), which partly restricts their applicability by other institutions. (author)

  16. Waste minimization in analytical methods

    International Nuclear Information System (INIS)

    Green, D.W.; Smith, L.L.; Crain, J.S.; Boparai, A.S.; Kiely, J.T.; Yaeger, J.S. Schilling, J.B.

    1995-01-01

    The US Department of Energy (DOE) will require a large number of waste characterizations over a multi-year period to accomplish the Department's goals in environmental restoration and waste management. Estimates vary, but two million analyses annually are expected. The waste generated by the analytical procedures used for characterizations is a significant source of new DOE waste. Success in reducing the volume of secondary waste and the costs of handling this waste would significantly decrease the overall cost of this DOE program. Selection of appropriate analytical methods depends on the intended use of the resultant data. It is not always necessary to use a high-powered analytical method, typically at higher cost, to obtain data needed to make decisions about waste management. Indeed, for samples taken from some heterogeneous systems, the meaning of high accuracy becomes clouded if the data generated are intended to measure a property of this system. Among the factors to be considered in selecting the analytical method are the lower limit of detection, accuracy, turnaround time, cost, reproducibility (precision), interferences, and simplicity. Occasionally, there must be tradeoffs among these factors to achieve the multiple goals of a characterization program. The purpose of the work described here is to add waste minimization to the list of characteristics to be considered. In this paper the authors present results of modifying analytical methods for waste characterization to reduce both the cost of analysis and volume of secondary wastes. Although tradeoffs may be required to minimize waste while still generating data of acceptable quality for the decision-making process, they have data demonstrating that wastes can be reduced in some cases without sacrificing accuracy or precision

  17. Frontier in nanoscale flows fractional calculus and analytical methods

    CERN Document Server

    Lewis, Roland; Liu, Hong-yan

    2014-01-01

    This ebook covers the basic properties of nanoscale flows, and various analytical and numerical methods for nanoscale flows and environmental flows. This ebook is a good reference not only for audience of the journal, but also for various communities in mathematics, nanotechnology and environmental science.

  18. Environmental Safety and Health Analytical Laboratory, Pantex Plant, Amarillo, Texas. Final Environmental Assessment

    International Nuclear Information System (INIS)

    1995-06-01

    The US Department of Energy (DOE) has prepared an Environmental Assessment (EA) of the construction and operation of an Environmental Safety and Health (ES ampersand H) Analytical Laboratory and subsequent demolition of the existing Analytical Chemistry Laboratory building at Pantex Plant near Amarillo, Texas. In accordance with the Council on Environmental Quality requirements contained in 40 CFR 1500--1508.9, the Environmental Assessment examined the environmental impacts of the Proposed Action and discussed potential alternatives. Based on the analysis of impacts in the EA, conducting the proposed action, construction of an analytical laboratory and demolition of the existing facility, would not significantly effect the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 (NEPA) and the Council on Environmental Quality regulations in 40 CFR 1508.18 and 1508.27

  19. Monitoring of emerging pollutants in Guadiamar River basin (South of Spain): analytical method, spatial distribution and environmental risk assessment.

    Science.gov (United States)

    Garrido, Eva; Camacho-Muñoz, Dolores; Martín, Julia; Santos, Antonio; Santos, Juan Luis; Aparicio, Irene; Alonso, Esteban

    2016-12-01

    Guadiamar River is located in the southwest of the Iberian Peninsula and connects two protected areas in the South of Spain: Sierra Morena and Doñana National Park. It is sited in an area affected by urban, industrial and agriculture sewage pollution and with tradition on intensive mining activities. Most of the studies performed in this area have been mainly focused on the presence of heavy metals and, until now, little is known about the occurrence of other contaminants such as emerging organic pollutants (EOPs). In this work, an analytical method has been optimized and validated for monitoring of forty-seven EOPs in surface water. The analytical method has been applied to study the distribution and environmental risk of these pollutants in Guadiamar River basin. The analytical method was based on solid-phase extraction and determination by liquid chromatography-triple quadrupole-tandem mass spectrometry. The 60 % of the target compounds were found in the analyzed samples. The highest concentrations were found for two plasticizers (bisphenol A and di(2-ethyhexyl)phthalate, mean concentration up to 930 ng/L) and two pharmaceutical compounds (caffeine (up to 623 ng/L) and salicylic acid (up to 318 ng/L)). This study allowed to evaluate the potential sources (industrial or urban) of the studied compounds and the spatial distribution of their concentrations along the river. Environmental risk assessment showed a major risk on the south of the river, mainly due to discharges of wastewater effluents.

  20. Environmental analytical laboratory setup operation and QA/QC

    International Nuclear Information System (INIS)

    Hsu, J.P.; Boyd, J.A.; DeViney, S.

    1991-01-01

    Environmental analysis requires precise and timely measurements. The required precise measurement is ensured with quality control and timeliness through an efficient operation. The efficiency of the operation also ensures cost-competitiveness. Environmental analysis plays a very important role in the environmental protection program. Due to the possible litigation involvement, most environmental analyses follow stringent criteria, such as the U.S. EPA Contract Laboratory Program procedures with analytical results documented in an orderly manner. The documentation demonstrates that all quality control steps are followed and facilitates data evaluation to determine the quality and usefulness of the data. Furthermore, the tedious documents concerning sample checking, chain-of-custody, standard or surrogate preparation, daily refrigerator and oven temperature monitoring, analytical and extraction logbooks, standard operation procedures, etc., also are an important part of the laboratory documentation. Quality control for environmental analysis is becoming more stringent, required documentation is becoming more detailed and turnaround time is shorter. However, the business is becoming more cost-competitive and it appears that this trend will continue. In this paper, we discuss what should be done to deal this high quality, fast-paced and tedious environmental analysis process at a competitive cost. The success of environmental analysis is people. The knowledge and experience of the staff are the key to a successful environmental analysis program. In order to be successful in this new area, the ability to develop new methods is crucial. In addition, the laboratory information system, laboratory automation and quality assurance/quality control (QA/QC) are major factors for laboratory success. This paper concentrates on these areas

  1. Decision support for environmental management of industrial non-hazardous secondary materials: New analytical methods combined with simulation and optimization modeling.

    Science.gov (United States)

    Little, Keith W; Koralegedara, Nadeesha H; Northeim, Coleen M; Al-Abed, Souhail R

    2017-07-01

    Non-hazardous solid materials from industrial processes, once regarded as waste and disposed in landfills, offer numerous environmental and economic advantages when put to beneficial uses (BUs). Proper management of these industrial non-hazardous secondary materials (INSM) requires estimates of their probable environmental impacts among disposal as well as BU options. The U.S. Environmental Protection Agency (EPA) has recently approved new analytical methods (EPA Methods 1313-1316) to assess leachability of constituents of potential concern in these materials. These new methods are more realistic for many disposal and BU options than historical methods, such as the toxicity characteristic leaching protocol. Experimental data from these new methods are used to parameterize a chemical fate and transport (F&T) model to simulate long-term environmental releases from flue gas desulfurization gypsum (FGDG) when disposed of in an industrial landfill or beneficially used as an agricultural soil amendment. The F&T model is also coupled with optimization algorithms, the Beneficial Use Decision Support System (BUDSS), under development by EPA to enhance INSM management. Published by Elsevier Ltd.

  2. Analytical Methods to Distinguish the Positive and Negative Spectra of Mineral and Environmental Elements Using Deep Ablation Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Kim, Dongyoung; Yang, Jun-Ho; Choi, Soojin; Yoh, Jack J

    2018-01-01

    Environments affect mineral surfaces, and the surface contamination or alteration can provide potential information to understanding their regional environments. However, when investigating mineral surfaces, mineral and environmental elements appear mixed in data. This makes it difficult to determine their atomic compositions independently. In this research, we developed four analytical methods to distinguish mineral and environmental elements into positive and negative spectra based on depth profiling data using laser-induced breakdown spectroscopy (LIBS). The principle of the methods is to utilize how intensity varied with depth for creating a new spectrum. The methods were applied to five mineral samples exposed to four environmental conditions including seawater, crude oil, sulfuric acid, and air as control. The proposed methods are then validated by applying the resultant spectra to principal component analysis and data were classified by the environmental conditions and atomic compositions of mineral. By applying the methods, the atomic information of minerals and environmental conditions were successfully inferred in the resultant spectrum.

  3. Environmental concentrations of engineered nanomaterials: Review of modeling and analytical studies

    International Nuclear Information System (INIS)

    Gottschalk, Fadri; Sun, TianYin; Nowack, Bernd

    2013-01-01

    Scientific consensus predicts that the worldwide use of engineered nanomaterials (ENM) leads to their release into the environment. We reviewed the available literature concerning environmental concentrations of six ENMs (TiO 2 , ZnO, Ag, fullerenes, CNT and CeO 2 ) in surface waters, wastewater treatment plant effluents, biosolids, sediments, soils and air. Presently, a dozen modeling studies provide environmental concentrations for ENM and a handful of analytical works can be used as basis for a preliminary validation. There are still major knowledge gaps (e.g. on ENM production, application and release) that affect the modeled values, but over all an agreement on the order of magnitude of the environmental concentrations can be reached. True validation of the modeled values is difficult because trace analytical methods that are specific for ENM detection and quantification are not available. The modeled and measured results are not always comparable due to the different forms and sizes of particles that these two approaches target. -- Highlights: •Modeled environmental concentrations of engineered nanomaterials are reviewed. •Measured environmental concentrations of engineered nanomaterials are reviewed. •Possible validation of modeled data by measurements is critically evaluated. •Different approaches in modeling and measurement methods complicate validation. -- Modeled and measured environmental concentrations of engineered nanomaterials are reviewed and critically discussed

  4. The Use and Abuse of Limits of Detection in Environmental Analytical Chemistry

    Directory of Open Access Journals (Sweden)

    Richard J. C. Brown

    2008-01-01

    Full Text Available The limit of detection (LoD serves as an important method performance measure that is useful for the comparison of measurement techniques and the assessment of likely signal to noise performance, especially in environmental analytical chemistry. However, the LoD is only truly related to the precision characteristics of the analytical instrument employed for the analysis and the content of analyte in the blank sample. This article discusses how other criteria, such as sampling volume, can serve to distort the quoted LoD artificially and make comparison between various analytical methods inequitable. In order to compare LoDs between methods properly, it is necessary to state clearly all of the input parameters relating to the measurements that have been used in the calculation of the LoD. Additionally, the article discusses that the use of LoDs in contexts other than the comparison of the attributes of analytical methods, in particular when reporting analytical results, may be confusing, less informative than quoting the actual result with an accompanying statement of uncertainty, and may act to bias descriptive statistics.

  5. Recent advances in analytical methods for the determination of 4-alkylphenols and bisphenol A in solid environmental matrices: A critical review.

    Science.gov (United States)

    Salgueiro-González, N; Castiglioni, S; Zuccato, E; Turnes-Carou, I; López-Mahía, P; Muniategui-Lorenzo, S

    2018-09-18

    The problem of endocrine disrupting compounds (EDCs) in the environment has become a worldwide concern in recent decades. Besides their toxicological effects at low concentrations and their widespread use in industrial and household applications, these pollutants pose a risk for non-target organisms and also for public safety. Analytical methods to determine these compounds at trace levels in different matrices are urgently needed. This review critically discusses trends in analytical methods for well-known EDCs like alkylphenols and bisphenol A in solid environmental matrices, including sediment and aquatic biological samples (from 2006 to 2018). Information about extraction, clean-up and determination is covered in detail, including analytical quality parameters (QA/QC). Conventional and novel analytical techniques are compared, with their advantages and drawbacks. Ultrasound assisted extraction followed by solid phase extraction clean-up is the most widely used procedure for sediment and aquatic biological samples, although softer extraction conditions have been employed for the latter. The use of liquid chromatography followed by tandem mass spectrometry has greatly increased in the last five years. The majority of these methods have been employed for the analysis of river sediments and bivalve molluscs because of their usefulness in aquatic ecosystem (bio)monitoring programs. Green, simple, fast analytical methods are now needed to determine these compounds in complex matrices. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Intercalibration of analytical methods on marine environmental samples

    International Nuclear Information System (INIS)

    1988-06-01

    The pollution of the seas by various chemical substances constitutes nowadays one of the principal concerns of mankind. The International Atomic Energy Agency has organized in past years several intercomparison exercises in the framework of its Analytical Quality Control Service. The present intercomparison had a double aim: first, to give laboratories participating in this intercomparison an opportunity for checking their analytical performance. Secondly, to produce on the basis of the results of this intercomparison a reference material made of fish tissue which would be accurately certified with respect to many trace elements. Such a material could be used by analytical chemists to check the validity of new analytical procedures. In total, 53 laboratories from 29 countries reported results (585 laboratory means for 48 elements). 5 refs, 52 tabs

  7. Industrial and environmental applications of nuclear analytical techniques. Report of a workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    The IAEA has programme the utilisation of nuclear analytical techniques (NATs), in particular for industrial and environmental applications. A major purpose is to help the developing Member States apply their analytical capabilities optimally for socio-economic progress and development. A large number of institutions in Europe, Africa, Latin America and Asia have established X ray fluorescence (XRF) and gamma ray measurement techniques and facilities for neutron activation analysis (NAA) have been initiated in institutions in these regions. Moreover, there is a growing interest among many institutes in applying more advanced analytical techniques, such as particle induced X ray emission (PIXE) and microanalytical techniques based on X ray emission induced by conventional sources or synchrotron radiation to the analysis of environmental and biological materials and industrial products. In order to define new areas of application of NATs and to extend the range of these techniques, a number of initiatives have recently been taken. It includes a workshop on industrial and environmental applications of nuclear analytical techniques, organized by the IAEA in Vienna, 7-11 September 1998. The main objectives of the workshop were as follows: (1) to review recent applications of NATs in industrial and environmental studies; (2) to identify emerging trends in methodologies and applications of NATs; (3) to demonstrate analytical capabilities of selected NATs. The following topics were reviewed during the workshop: (1) XRF and accelerator based analytical techniques; (2) portable XRF systems and their applications in industry, mineral prospecting and processing, (3) portable gamma ray spectrometers; and (4) NAA and its applications in industry and environmental studies. Micro-XRF and micro-PIXE methods and their applications in the above fields were also discussed, including aspects of synchrotron radiation induced X ray emission.

  8. Industrial and environmental applications of nuclear analytical techniques. Report of a workshop

    International Nuclear Information System (INIS)

    1999-11-01

    The IAEA has programme the utilisation of nuclear analytical techniques (NATs), in particular for industrial and environmental applications. A major purpose is to help the developing Member States apply their analytical capabilities optimally for socio-economic progress and development. A large number of institutions in Europe, Africa, Latin America and Asia have established X ray fluorescence (XRF) and gamma ray measurement techniques and facilities for neutron activation analysis (NAA) have been initiated in institutions in these regions. Moreover, there is a growing interest among many institutes in applying more advanced analytical techniques, such as particle induced X ray emission (PIXE) and microanalytical techniques based on X ray emission induced by conventional sources or synchrotron radiation to the analysis of environmental and biological materials and industrial products. In order to define new areas of application of NATs and to extend the range of these techniques, a number of initiatives have recently been taken. It includes a workshop on industrial and environmental applications of nuclear analytical techniques, organized by the IAEA in Vienna, 7-11 September 1998. The main objectives of the workshop were as follows: (1) to review recent applications of NATs in industrial and environmental studies; (2) to identify emerging trends in methodologies and applications of NATs; (3) to demonstrate analytical capabilities of selected NATs. The following topics were reviewed during the workshop: (1) XRF and accelerator based analytical techniques; (2) portable XRF systems and their applications in industry, mineral prospecting and processing, (3) portable gamma ray spectrometers; and (4) NAA and its applications in industry and environmental studies. Micro-XRF and micro-PIXE methods and their applications in the above fields were also discussed, including aspects of synchrotron radiation induced X ray emission

  9. 40 CFR 425.03 - Sulfide analytical methods and applicability.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Sulfide analytical methods and applicability. 425.03 Section 425.03 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY General Provisions...

  10. Analytical method comparisons for the accurate determination of PCBs in sediments

    Energy Technology Data Exchange (ETDEWEB)

    Numata, M.; Yarita, T.; Aoyagi, Y.; Yamazaki, M.; Takatsu, A. [National Metrology Institute of Japan, Tsukuba (Japan)

    2004-09-15

    National Metrology Institute of Japan in National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has been developing several matrix reference materials, for example, sediments, water and biological tissues, for the determinations of heavy metals and organometallic compounds. The matrix compositions of those certified reference materials (CRMs) are similar to compositions of actual samples, and those are useful for validating analytical procedures. ''Primary methods of measurements'' are essential to obtain accurate and SI-traceable certified values in the reference materials, because the methods have the highest quality of measurement. However, inappropriate analytical operations, such as incomplete extraction of analytes or crosscontamination during analytical procedures, will cause error of analytical results, even if one of the primary methods, isotope-dilution, is utilized. To avoid possible procedural bias for the certification of reference materials, we employ more than two analytical methods which have been optimized beforehand. Because the accurate determination of trace POPs in the environment is important to evaluate their risk, reliable CRMs are required by environmental chemists. Therefore, we have also been preparing matrix CRMs for the determination of POPs. To establish accurate analytical procedures for the certification of POPs, extraction is one of the critical steps as described above. In general, conventional extraction techniques for the determination of POPs, such as Soxhlet extraction (SOX) and saponification (SAP), have been characterized well, and introduced as official methods for environmental analysis. On the other hand, emerging techniques, such as microwave-assisted extraction (MAE), pressurized fluid extraction (PFE) and supercritical fluid extraction (SFE), give higher recovery yields of analytes with relatively short extraction time and small amount of solvent, by reasons of the high

  11. Literature Review on Processing and Analytical Methods for ...

    Science.gov (United States)

    Report The purpose of this report was to survey the open literature to determine the current state of the science regarding the processing and analytical methods currently available for recovery of F. tularensis from water and soil matrices, and to determine what gaps remain in the collective knowledge concerning F. tularensis identification from environmental samples.

  12. Analytical method of waste allocation in waste management systems: Concept, method and case study

    Energy Technology Data Exchange (ETDEWEB)

    Bergeron, Francis C., E-mail: francis.b.c@videotron.ca

    2017-01-15

    Waste is not a rejected item to dispose anymore but increasingly a secondary resource to exploit, influencing waste allocation among treatment operations in a waste management (WM) system. The aim of this methodological paper is to present a new method for the assessment of the WM system, the “analytical method of the waste allocation process” (AMWAP), based on the concept of the “waste allocation process” defined as the aggregation of all processes of apportioning waste among alternative waste treatment operations inside or outside the spatial borders of a WM system. AMWAP contains a conceptual framework and an analytical approach. The conceptual framework includes, firstly, a descriptive model that focuses on the description and classification of the WM system. It includes, secondly, an explanatory model that serves to explain and to predict the operation of the WM system. The analytical approach consists of a step-by-step analysis for the empirical implementation of the conceptual framework. With its multiple purposes, AMWAP provides an innovative and objective modular method to analyse a WM system which may be integrated in the framework of impact assessment methods and environmental systems analysis tools. Its originality comes from the interdisciplinary analysis of the WAP and to develop the conceptual framework. AMWAP is applied in the framework of an illustrative case study on the household WM system of Geneva (Switzerland). It demonstrates that this method provides an in-depth and contextual knowledge of WM. - Highlights: • The study presents a new analytical method based on the waste allocation process. • The method provides an in-depth and contextual knowledge of the waste management system. • The paper provides a reproducible procedure for professionals, experts and academics. • It may be integrated into impact assessment or environmental system analysis tools. • An illustrative case study is provided based on household waste

  13. Analytical method of waste allocation in waste management systems: Concept, method and case study

    International Nuclear Information System (INIS)

    Bergeron, Francis C.

    2017-01-01

    Waste is not a rejected item to dispose anymore but increasingly a secondary resource to exploit, influencing waste allocation among treatment operations in a waste management (WM) system. The aim of this methodological paper is to present a new method for the assessment of the WM system, the “analytical method of the waste allocation process” (AMWAP), based on the concept of the “waste allocation process” defined as the aggregation of all processes of apportioning waste among alternative waste treatment operations inside or outside the spatial borders of a WM system. AMWAP contains a conceptual framework and an analytical approach. The conceptual framework includes, firstly, a descriptive model that focuses on the description and classification of the WM system. It includes, secondly, an explanatory model that serves to explain and to predict the operation of the WM system. The analytical approach consists of a step-by-step analysis for the empirical implementation of the conceptual framework. With its multiple purposes, AMWAP provides an innovative and objective modular method to analyse a WM system which may be integrated in the framework of impact assessment methods and environmental systems analysis tools. Its originality comes from the interdisciplinary analysis of the WAP and to develop the conceptual framework. AMWAP is applied in the framework of an illustrative case study on the household WM system of Geneva (Switzerland). It demonstrates that this method provides an in-depth and contextual knowledge of WM. - Highlights: • The study presents a new analytical method based on the waste allocation process. • The method provides an in-depth and contextual knowledge of the waste management system. • The paper provides a reproducible procedure for professionals, experts and academics. • It may be integrated into impact assessment or environmental system analysis tools. • An illustrative case study is provided based on household waste

  14. Eco-analytical Methodology in Environmental Problems Monitoring

    Science.gov (United States)

    Agienko, M. I.; Bondareva, E. P.; Chistyakova, G. V.; Zhironkina, O. V.; Kalinina, O. I.

    2017-01-01

    Among the problems common to all mankind, which solutions influence the prospects of civilization, the problem of ecological situation monitoring takes very important place. Solution of this problem requires specific methodology based on eco-analytical comprehension of global issues. Eco-analytical methodology should help searching for the optimum balance between environmental problems and accelerating scientific and technical progress. The fact that Governments, corporations, scientists and nations focus on the production and consumption of material goods cause great damage to environment. As a result, the activity of environmentalists is developing quite spontaneously, as a complement to productive activities. Therefore, the challenge posed by the environmental problems for the science is the formation of geo-analytical reasoning and the monitoring of global problems common for the whole humanity. So it is expected to find the optimal trajectory of industrial development to prevent irreversible problems in the biosphere that could stop progress of civilization.

  15. EPA's analytical methods for water: The next generation

    International Nuclear Information System (INIS)

    Hites, R.A.; Budde, W.L.

    1991-01-01

    By the late 1970s, it had become clear to EPA that organic compounds were polluting many of the nation's waters. By 1977, as a result of a lawsuit by several environmentally concerned plaintiffs, EPA had focused on a list of 114 'priority' organic pollutants. Its long-term goal was the regulation of specific compounds that were found to pose significant environmental problems, a daunting task. Tens of thousands of samples needed to be measured by hundreds of different laboratories. Clearly, there were concerns about the comparability of data among laboratories. The result was a series of laboratory-based analytical 'methods.' These EPA methods are detailed, step-by-step directions (recipes) that describe everything the analyst needs to know to complete a satisfactory analysis. During the 1970s the first set of methods was developed; this was the '600 series' for the analysis of organic compounds in wastewater. In 1979 and the 1980s, a set of '500 series' methods, focusing on drinking water, was developed. By now, many of the 500 and 600 series methods are in widespread use, and it is clear that there are considerably overlaps among the methods in terms of both procedures and analytes. Indiana University was asked by EPA to consider the question, 'Is it possible to revise or eliminate some of the 500 and 600 series methods and effect a savings of time and money?' This and related questions were studied and recommendations were developed

  16. Analytical chromatography. Methods, instrumentation and applications

    International Nuclear Information System (INIS)

    Yashin, Ya I; Yashin, A Ya

    2006-01-01

    The state-of-the-art and the prospects in the development of main methods of analytical chromatography, viz., gas, high performance liquid and ion chromatographic techniques, are characterised. Achievements of the past 10-15 years in the theory and general methodology of chromatography and also in the development of new sorbents, columns and chromatographic instruments are outlined. The use of chromatography in the environmental control, biology, medicine, pharmaceutics, and also for monitoring the quality of foodstuffs and products of chemical, petrochemical and gas industries, etc. is considered.

  17. Prioritizing pesticide compounds for analytical methods development

    Science.gov (United States)

    Norman, Julia E.; Kuivila, Kathryn; Nowell, Lisa H.

    2012-01-01

    The U.S. Geological Survey (USGS) has a periodic need to re-evaluate pesticide compounds in terms of priorities for inclusion in monitoring and studies and, thus, must also assess the current analytical capabilities for pesticide detection. To meet this need, a strategy has been developed to prioritize pesticides and degradates for analytical methods development. Screening procedures were developed to separately prioritize pesticide compounds in water and sediment. The procedures evaluate pesticide compounds in existing USGS analytical methods for water and sediment and compounds for which recent agricultural-use information was available. Measured occurrence (detection frequency and concentrations) in water and sediment, predicted concentrations in water and predicted likelihood of occurrence in sediment, potential toxicity to aquatic life or humans, and priorities of other agencies or organizations, regulatory or otherwise, were considered. Several existing strategies for prioritizing chemicals for various purposes were reviewed, including those that identify and prioritize persistent, bioaccumulative, and toxic compounds, and those that determine candidates for future regulation of drinking-water contaminants. The systematic procedures developed and used in this study rely on concepts common to many previously established strategies. The evaluation of pesticide compounds resulted in the classification of compounds into three groups: Tier 1 for high priority compounds, Tier 2 for moderate priority compounds, and Tier 3 for low priority compounds. For water, a total of 247 pesticide compounds were classified as Tier 1 and, thus, are high priority for inclusion in analytical methods for monitoring and studies. Of these, about three-quarters are included in some USGS analytical method; however, many of these compounds are included on research methods that are expensive and for which there are few data on environmental samples. The remaining quarter of Tier 1

  18. Review and evaluation of spark source mass spectrometry as an analytical method

    International Nuclear Information System (INIS)

    Beske, H.E.

    1981-01-01

    The analytical features and most important fields of application of spark source mass spectrometry are described with respect to the trace analysis of high-purity materials and the multielement analysis of technical alloys, geochemical and cosmochemical, biological and radioactive materials, as well as in environmental analysis. Comparisons are made to other analytical methods. The distribution of the method as well as opportunities for contract analysis are indicated and developmental tendencies discussed. (orig.) [de

  19. DOE methods for evaluating environmental and waste management samples

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K. [eds.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  20. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, open-quotes Draftclose quotes or open-quotes Verifiedclose quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy

  1. Role of analytical chemistry in environmental monitoring

    International Nuclear Information System (INIS)

    Kayasth, S.; Swain, K.

    2004-01-01

    Basic aspects of pollution and the role of analytical chemistry in environmental monitoring are highlighted and exemplified, with emphasis on trace elements. Sources and pathways of natural and especially man-made polluting substances as well as physico-chemical characteristics are given. Attention is paid to adequate sampling in various compartments of the environment comprising both lithosphere and biosphere. Trace analysis is dealt with using a variety of analytical techniques, including criteria for choice of suited techniques, as well as aspects of analytical quality assurance and control. Finally, some data on trace elements levels in soil and water samples from India are presented. (author)

  2. Analytical and environmental aspects of the flame retardant tetrabromobisphenol-A and its derivatives.

    Science.gov (United States)

    Covaci, Adrian; Voorspoels, Stefan; Abdallah, Mohamed Abou-Elwafa; Geens, Tinne; Harrad, Stuart; Law, Robin J

    2009-01-16

    The present article reviews the available literature on the analytical and environmental aspects of tetrabromobisphenol-A (TBBP-A), a currently intensively used brominated flame retardant (BFR). Analytical methods, including sample preparation, chromatographic separation, detection techniques, and quality control are discussed. An important recent development in the analysis of TBBP-A is the growing tendency for liquid chromatographic techniques. At the detection stage, mass-spectrometry is a well-established and reliable technology in the identification and quantification of TBBP-A. Although interlaboratory exercises for BFRs have grown in popularity in the last 10 years, only a few participating laboratories report concentrations for TBBP-A. Environmental levels of TBBP-A in abiotic and biotic matrices are low, probably due to the major use of TBBP-A as reactive FR. As a consequence, the expected human exposure is low. This is in agreement with the EU risk assessment that concluded that there is no risk for humans concerning TBBP-A exposure. Much less analytical and environmental information exists for the various groups of TBBP-A derivatives which are largely used as additive flame retardants.

  3. Nuclear analytical techniques and their application to environmental samples

    International Nuclear Information System (INIS)

    Lieser, K.H.

    1986-01-01

    A survey is given on nuclear analytical techniques and their application to environmental samples. Measurement of the inherent radioactivity of elements or radionuclides allows determination of natural radioelements (e.g. Ra), man-made radioelements (e.g. Pu) and radionuclides in the environment. Activation analysis, in particular instrumental neutron activation analysis, is a very reliable and sensitive method for determination of a great number of trace elements in environmental samples, because the most abundant main constituents are not activated. Tracer techniques are very useful for studies of the behaviour and of chemical reactions of trace elements and compounds in the environment. Radioactive sources are mainly applied for excitation of characteristic X-rays (X-ray fluorescence analysis). (author)

  4. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Laboratory Management Division of the DOE. Methods are prepared for entry into DOE Methods as chapter editors, together with DOE and other participants in this program, identify analytical and sampling method needs. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types. open-quotes Draftclose quotes or open-quotes Verified.close quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations

  5. Environmental Stewardship: A Conceptual Review and Analytical Framework

    Science.gov (United States)

    Bennett, Nathan J.; Whitty, Tara S.; Finkbeiner, Elena; Pittman, Jeremy; Bassett, Hannah; Gelcich, Stefan; Allison, Edward H.

    2018-04-01

    There has been increasing attention to and investment in local environmental stewardship in conservation and environmental management policies and programs globally. Yet environmental stewardship has not received adequate conceptual attention. Establishing a clear definition and comprehensive analytical framework could strengthen our ability to understand the factors that lead to the success or failure of environmental stewardship in different contexts and how to most effectively support and enable local efforts. Here we propose such a definition and framework. First, we define local environmental stewardship as the actions taken by individuals, groups or networks of actors, with various motivations and levels of capacity, to protect, care for or responsibly use the environment in pursuit of environmental and/or social outcomes in diverse social-ecological contexts. Next, drawing from a review of the environmental stewardship, management and governance literatures, we unpack the elements of this definition to develop an analytical framework that can facilitate research on local environmental stewardship. Finally, we discuss potential interventions and leverage points for promoting or supporting local stewardship and future applications of the framework to guide descriptive, evaluative, prescriptive or systematic analysis of environmental stewardship. Further application of this framework in diverse environmental and social contexts is recommended to refine the elements and develop insights that will guide and improve the outcomes of environmental stewardship initiatives and investments. Ultimately, our aim is to raise the profile of environmental stewardship as a valuable and holistic concept for guiding productive and sustained relationships with the environment.

  6. Environmental Stewardship: A Conceptual Review and Analytical Framework.

    Science.gov (United States)

    Bennett, Nathan J; Whitty, Tara S; Finkbeiner, Elena; Pittman, Jeremy; Bassett, Hannah; Gelcich, Stefan; Allison, Edward H

    2018-04-01

    There has been increasing attention to and investment in local environmental stewardship in conservation and environmental management policies and programs globally. Yet environmental stewardship has not received adequate conceptual attention. Establishing a clear definition and comprehensive analytical framework could strengthen our ability to understand the factors that lead to the success or failure of environmental stewardship in different contexts and how to most effectively support and enable local efforts. Here we propose such a definition and framework. First, we define local environmental stewardship as the actions taken by individuals, groups or networks of actors, with various motivations and levels of capacity, to protect, care for or responsibly use the environment in pursuit of environmental and/or social outcomes in diverse social-ecological contexts. Next, drawing from a review of the environmental stewardship, management and governance literatures, we unpack the elements of this definition to develop an analytical framework that can facilitate research on local environmental stewardship. Finally, we discuss potential interventions and leverage points for promoting or supporting local stewardship and future applications of the framework to guide descriptive, evaluative, prescriptive or systematic analysis of environmental stewardship. Further application of this framework in diverse environmental and social contexts is recommended to refine the elements and develop insights that will guide and improve the outcomes of environmental stewardship initiatives and investments. Ultimately, our aim is to raise the profile of environmental stewardship as a valuable and holistic concept for guiding productive and sustained relationships with the environment.

  7. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1993-03-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others

  8. DOE methods for evaluating environmental and waste management samples.

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K [eds.; Pacific Northwest Lab., Richland, WA (United States)

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  9. Nuclear analytical methods for platinum group elements

    International Nuclear Information System (INIS)

    2005-04-01

    Platinum group elements (PGE) are of special interest for analytical research due to their economic importance like chemical peculiarities as catalysts, medical applications as anticancer drugs, and possible environmental detrimental impact as exhaust from automobile catalyzers. Natural levels of PGE are so low in concentration that most of the current analytical techniques approach their limit of detection capacity. In addition, Ru, Rh, Pd, Re, Os, Ir, and Pt analyses still constitute a challenge in accuracy and precision of quantification in natural matrices. Nuclear analytical techniques, such as neutron activation analysis, X ray fluorescence, or proton-induced X ray emission (PIXE), which are generally considered as reference methods for many analytical problems, are useful as well. However, due to methodological restrictions, they can, in most cases, only be applied after pre-concentration and under special irradiation conditions. This report was prepared following a coordinated research project and a consultants meeting addressing the subject from different viewpoints. The experts involved suggested to discuss the issue according to the (1) application, hence, the concentration levels encountered, and (2) method applied for analysis. Each of the different fields of application needs special consideration for sample preparation, PGE pre-concentration, and determination. Additionally, each analytical method requires special attention regarding the sensitivity and sample type. Quality assurance/quality control aspects are considered towards the end of the report. It is intended to provide the reader of this publication with state-of-the-art information on the various aspects of PGE analysis and to advise which technique might be most suitable for a particular analytical problem related to platinum group elements. In particular, many case studies described in detail from the authors' laboratory experience might help to decide which way to go. As in many cases

  10. 7 CFR 94.303 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 94.303 Section 94.303 Agriculture... POULTRY AND EGG PRODUCTS Processed Poultry Products § 94.303 Analytical methods. The analytical methods... latest edition of the Official Methods of Analysis of AOAC INTERNATIONAL, Suite 500, 481 North Frederick...

  11. Analytical study on the determination of boron in environmental water samples

    International Nuclear Information System (INIS)

    Lopez, F.J.; Gimenez, E.; Hernandez, F.

    1993-01-01

    An analytical study on the determination of boron in environmental water samples was carried out. The curcumin and carmine standard methods were compared with the most recent Azomethine-H method in order to evaluate their analytical characteristics and feasibility for the analysis of boron in water samples. Analyses of synthetic water, ground water, sea water and waste water samples were carried out and a statistical evaluation of the results was made. The Azomethine-H method was found to be the most sensitive (detection limit 0.02 mg l -1 ) and selective (no interference of commonly occurring ions in water was observed), showing also the best precision (relative standard deviation lower than 4%). Moreover, it gave good results for all types of samples analyzed. The accuracy of this method was tested by the addition of known amounts of standard solutions to different types of water samples. The slopes of standard additions and direct calibration graphs were similar and recoveries of added boron ranged from 99 to 107%. (orig.)

  12. 7 CFR 98.4 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 98.4 Section 98.4 Agriculture....4 Analytical methods. (a) The majority of analytical methods used by the USDA laboratories to perform analyses of meat, meat food products and MRE's are listed as follows: (1) Official Methods of...

  13. Steroid hormones in environmental matrices: extraction method comparison.

    Science.gov (United States)

    Andaluri, Gangadhar; Suri, Rominder P S; Graham, Kendon

    2017-11-09

    The U.S. Environmental Protection Agency (EPA) has developed methods for the analysis of steroid hormones in water, soil, sediment, and municipal biosolids by HRGC/HRMS (EPA Method 1698). Following the guidelines provided in US-EPA Method 1698, the extraction methods were validated with reagent water and applied to municipal wastewater, surface water, and municipal biosolids using GC/MS/MS for the analysis of nine most commonly detected steroid hormones. This is the first reported comparison of the separatory funnel extraction (SFE), continuous liquid-liquid extraction (CLLE), and Soxhlet extraction methods developed by the U.S. EPA. Furthermore, a solid phase extraction (SPE) method was also developed in-house for the extraction of steroid hormones from aquatic environmental samples. This study provides valuable information regarding the robustness of the different extraction methods. Statistical analysis of the data showed that SPE-based methods provided better recovery efficiencies and lower variability of the steroid hormones followed by SFE. The analytical methods developed in-house for extraction of biosolids showed a wide recovery range; however, the variability was low (≤ 7% RSD). Soxhlet extraction and CLLE are lengthy procedures and have been shown to provide highly variably recovery efficiencies. The results of this study are guidance for better sample preparation strategies in analytical methods for steroid hormone analysis, and SPE adds to the choice in environmental sample analysis.

  14. Theoretical, analytical, and statistical interpretation of environmental data

    International Nuclear Information System (INIS)

    Lombard, S.M.

    1974-01-01

    The reliability of data from radiochemical analyses of environmental samples cannot be determined from nuclear counting statistics alone. The rigorous application of the principles of propagation of errors, an understanding of the physics and chemistry of the species of interest in the environment, and the application of information from research on the analytical procedure are all necessary for a valid estimation of the errors associated with analytical results. The specific case of the determination of plutonium in soil is considered in terms of analytical problems and data reliability. (U.S.)

  15. 7 CFR 93.4 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 93.4 Section 93.4 Agriculture... PROCESSED FRUITS AND VEGETABLES Citrus Juices and Certain Citrus Products § 93.4 Analytical methods. (a) The majority of analytical methods for citrus products are found in the Official Methods of Analysis of AOAC...

  16. 7 CFR 94.103 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 94.103 Section 94.103 Agriculture... POULTRY AND EGG PRODUCTS Voluntary Analyses of Egg Products § 94.103 Analytical methods. The analytical methods used by the Science and Technology Division laboratories to perform voluntary analyses for egg...

  17. 35th International Symposium on Environmental Analytical Chemistry - ISEAC 35. Book of Abstracts

    International Nuclear Information System (INIS)

    Namiestnik, J.; Gdaniec-Pietryka, M.; Klimaszewska, K.; Gorecka, A.; Sagajdakow, A.; Jakubowska, N.

    2008-01-01

    The ISEAC 35 is organized by the International Association of Environmental Analytical Chemistry (IAEAC), the Committee on Analytical Chemistry of the Polish Academy of Science (PAS), and the Chemical Faculty of Gdansk University of Technology (GUT). The Symposium includes a number of invited lectures treating frontier topics of environmental analytical chemistry, such as: (a) miniaturized spectroscopic tools for environmental survey analysis, (b) remote sensing in marine research, (c) xenobiotics in natural waters, (d) sampling and sample handling for environmental analysis. Book of Abstracts contains abstracts of 9 invited lectures, 62 oral presentations and 250 posters.

  18. Analytical methods for the determination of mixtures of bisphenols and derivatives in human and environmental exposure sources and biological fluids. A review

    International Nuclear Information System (INIS)

    Caballero-Casero, N.; Lunar, L.; Rubio, S.

    2016-01-01

    Bisphenol A (BPA) is ubiquitous in humans and the environment. Its potential adverse effects through genomic and non-genomic pathways have fostered BPA replacement by bisphenol analogs that, unfortunately, exert similar adverse effects. Many of these analogs, as well as their derivatives, have already found in humans and the environment and major concerns have arisen over their low dose- and mixture-related effects. This review aims to discuss the characteristics of the main analytical methods reported so far for the determination of mixtures of bisphenol analogs and/or derivatives in human and environmental exposure sources and biological fluids. Approaches followed for removal of background contamination, sample preparation and separation and detection of mixtures of bisphenols and derivatives are critically discussed. Sample treatment is matrix-dependent and common steps include analyte isolation, removal of interferences, evaporation of the extracts and solvent reconstitution. Separation and quantification has been almost exclusively carried out by liquid chromatography tandem mass spectrometry (LC-MS/MS) or gas chromatography mass spectrometry (GC–MS), in the last case prior derivatization, but LC-fluorescence detection has also found some applications. Main characteristics, advantages and drawbacks of these methods will be comparatively discussed. Although at an early stage, some approaches for the assessment of the risk to mixtures of bisphenols, mainly based on the combination of chemical target analysis and toxicity evaluation, have been already applied and they will be here presented. Current knowledge gaps hindering a reliable assessment of human and environmental risk to mixtures of bisphenols and derivatives will be outlined. - Highlights: • Analytical methods for the (bio)monitoring of mixtures of bisphenols are reviewed. • LC and CG coupled to MS are the preferred techniques. • Method-dependent sample treatments are required to remove matrix

  19. Analytical methods for the determination of mixtures of bisphenols and derivatives in human and environmental exposure sources and biological fluids. A review

    Energy Technology Data Exchange (ETDEWEB)

    Caballero-Casero, N.; Lunar, L.; Rubio, S., E-mail: qa1rubrs@uco.es

    2016-02-18

    Bisphenol A (BPA) is ubiquitous in humans and the environment. Its potential adverse effects through genomic and non-genomic pathways have fostered BPA replacement by bisphenol analogs that, unfortunately, exert similar adverse effects. Many of these analogs, as well as their derivatives, have already found in humans and the environment and major concerns have arisen over their low dose- and mixture-related effects. This review aims to discuss the characteristics of the main analytical methods reported so far for the determination of mixtures of bisphenol analogs and/or derivatives in human and environmental exposure sources and biological fluids. Approaches followed for removal of background contamination, sample preparation and separation and detection of mixtures of bisphenols and derivatives are critically discussed. Sample treatment is matrix-dependent and common steps include analyte isolation, removal of interferences, evaporation of the extracts and solvent reconstitution. Separation and quantification has been almost exclusively carried out by liquid chromatography tandem mass spectrometry (LC-MS/MS) or gas chromatography mass spectrometry (GC–MS), in the last case prior derivatization, but LC-fluorescence detection has also found some applications. Main characteristics, advantages and drawbacks of these methods will be comparatively discussed. Although at an early stage, some approaches for the assessment of the risk to mixtures of bisphenols, mainly based on the combination of chemical target analysis and toxicity evaluation, have been already applied and they will be here presented. Current knowledge gaps hindering a reliable assessment of human and environmental risk to mixtures of bisphenols and derivatives will be outlined. - Highlights: • Analytical methods for the (bio)monitoring of mixtures of bisphenols are reviewed. • LC and CG coupled to MS are the preferred techniques. • Method-dependent sample treatments are required to remove matrix

  20. A review of electro analytical determinations of some important elements (Zn, Se, As) in environmental samples

    International Nuclear Information System (INIS)

    Lichiang; James, B.D.; Magee, R.J.

    1991-01-01

    This review covers electro analytical methods reported in the literature for the determination of zinc, cadmium, selenium and arsenic in environmental and biological samples. A comprehensive survey of electro analytical techniques used for the determination of four important elements, i.e. zinc, cadmium, selenium and arsenic is reported herein with 322 references up to 1990. (Orig./A.B.)

  1. 7 CFR 94.4 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 94.4 Section 94.4 Agriculture... POULTRY AND EGG PRODUCTS Mandatory Analyses of Egg Products § 94.4 Analytical methods. The majority of analytical methods used by the USDA laboratories to perform mandatory analyses for egg products are listed as...

  2. Hanford environmental analytical methods: Methods as of March 1990. Volume 3, Appendix A2-I

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Daniel, J.L.

    1993-05-01

    This paper from the analytical laboratories at Hanford describes the method used to measure pH of single-shell tank core samples. Sludge or solid samples are mixed with deionized water. The pH electrode used combines both a sensor and reference electrode in one unit. The meter amplifies the input signal from the electrode and displays the pH visually.

  3. [Progress in sample preparation and analytical methods for trace polar small molecules in complex samples].

    Science.gov (United States)

    Zhang, Qianchun; Luo, Xialin; Li, Gongke; Xiao, Xiaohua

    2015-09-01

    Small polar molecules such as nucleosides, amines, amino acids are important analytes in biological, food, environmental, and other fields. It is necessary to develop efficient sample preparation and sensitive analytical methods for rapid analysis of these polar small molecules in complex matrices. Some typical materials in sample preparation, including silica, polymer, carbon, boric acid and so on, are introduced in this paper. Meanwhile, the applications and developments of analytical methods of polar small molecules, such as reversed-phase liquid chromatography, hydrophilic interaction chromatography, etc., are also reviewed.

  4. Comparison of the analytical methods used to determine natural and artificial radionuclides from environmental samples by gamma, alpha and beta spectrometry

    DEFF Research Database (Denmark)

    Pöllänen, Roy; Virtanen, Sinikka; Kämäräinen, Meerit

    In CAMNAR, an extensive interlaboratory exercise on the analytical methods used to determine several radionuclides present in the environmental samples was organized. Activity concentration of different natural radionuclides, such as Rn-222, Pb-210, Po-210, K-40, Ra-226, Ra-228 and isotopes...... of uranium, in addition to artificial Cs-137 and Am-241 were analysed from lake sediment samples and drinking water. The measurement techniques were gamma-ray spectrometry, alpha spectrometry, liquid scintillation counting and inductively coupled plasma mass spectrometry. Twenty six laboratories from nine...

  5. Comparison of nuclear analytical methods with competitive methods

    International Nuclear Information System (INIS)

    1987-10-01

    The use of nuclear analytical techniques, especially neutron activation analysis, already have a 50 year old history. Today several sensitive and accurate, non-nuclear trace element analytical techniques are available and new methods are continuously developed. The IAEA is supporting the development of nuclear analytical laboratories in its Member States. In order to be able to advise the developing countries which methods to use in different applications, it is important to know the present status and development trends of nuclear analytical methods, what are their benefits, drawbacks and recommended fields of application, compared with other, non-nuclear techniques. In order to get an answer to these questions the IAEA convened this Advisory Group Meeting. This volume is the outcome of the presentations and discussions of the meeting. A separate abstract was prepared for each of the 21 papers. Refs, figs, tabs

  6. Environmental Warning System Based on the DPSIR Model: A Practical and Concise Method for Environmental Assessment

    Directory of Open Access Journals (Sweden)

    Wenqi Wang

    2018-05-01

    Full Text Available Though we are in urgent need of environmental warnings to slow environmental deterioration, currently, there is no internationally concise method for environmental warnings. In addition, the existing approaches do not combine the three aspects of ecology, resources, and environment. At the same time, the three elements of the environment (air, water, and soil are separated in most environmental warning systems. Thus, the method this paper gives is an innovative attempt and aims to make environmental assessment more practical. This paper establishes the index system of an environmental early warning based on the Driving–Pressure–State–Influence–Response (DPSIR model. The Analytic Hierarchy Process (AHP method was used to determine the weights. Next, single and integrated index methods further assess the environmental warning state, in which the weighted summation method is used to summarize the data and results. The case of Tianjin is used to confirm the applicability of this method. In conclusion, the method in this paper is more well-behaved and, therefore, more suitable to assist cities in their environmental assessment.

  7. Island Explorations: Discovering Effects of Environmental Research-Based Lab Activities on Analytical Chemistry Students

    Science.gov (United States)

    Tomasik, Janice Hall; LeCaptain, Dale; Murphy, Sarah; Martin, Mary; Knight, Rachel M.; Harke, Maureen A.; Burke, Ryan; Beck, Kara; Acevedo-Polakovich, I. David

    2014-01-01

    Motivating students in analytical chemistry can be challenging, in part because of the complexity and breadth of topics involved. Some methods that help encourage students and convey real-world relevancy of the material include incorporating environmental issues, research-based lab experiments, and service learning projects. In this paper, we…

  8. Life cycle management of analytical methods.

    Science.gov (United States)

    Parr, Maria Kristina; Schmidt, Alexander H

    2018-01-05

    In modern process management, the life cycle concept gains more and more importance. It focusses on the total costs of the process from invest to operation and finally retirement. Also for analytical procedures an increasing interest for this concept exists in the recent years. The life cycle of an analytical method consists of design, development, validation (including instrumental qualification, continuous method performance verification and method transfer) and finally retirement of the method. It appears, that also regulatory bodies have increased their awareness on life cycle management for analytical methods. Thus, the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH), as well as the United States Pharmacopeial Forum discuss the enrollment of new guidelines that include life cycle management of analytical methods. The US Pharmacopeia (USP) Validation and Verification expert panel already proposed a new General Chapter 〈1220〉 "The Analytical Procedure Lifecycle" for integration into USP. Furthermore, also in the non-regulated environment a growing interest on life cycle management is seen. Quality-by-design based method development results in increased method robustness. Thereby a decreased effort is needed for method performance verification, and post-approval changes as well as minimized risk of method related out-of-specification results. This strongly contributes to reduced costs of the method during its life cycle. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Materials of the Second Sumy-Cracow-Muenster Symposium on Nuclear Analytical Methods

    International Nuclear Information System (INIS)

    2001-01-01

    The applications of nuclear analytical methods in physico-chemical, biological and medical studies have been presented in large number of applications. Environmental, geological and biological materials have been analysed by means of neutron activation analysis, proton microprobe, x-ray diffraction, synchrotron radiation X-ray spectrum analysis, ESR and others

  10. The multicriteria method for environmentally oriented business decision-making

    Directory of Open Access Journals (Sweden)

    Čančer Vesna

    2004-01-01

    Full Text Available Stimulated by the expressed managers’ need for some completed methods for environmental management in enterprises, we present the method for environmentally oriented business decision-making. It is based on simulations where optimization models of business processes are used as scenarios. The possibilities for an integrated approach to environmental protection are introduced and – decomposed according to the type of the considered element by using zero-one variables – included in the optimization models. The method is completed for multicriteria decision-making where in the simulations obtained optimal values are included. In a real-life case where the Analytic Hierarchy Process technique is used to evaluate environmentally oriented business processes, special attention is given to criteria and weights: we consider preferences and survey findings on the environmental impact of business processes in the enterprise, survey findings on environmental management in the processing industry, and ecobalances.

  11. 40 CFR 141.704 - Analytical methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Analytical methods. 141.704 Section... Monitoring Requirements § 141.704 Analytical methods. (a) Cryptosporidium. Systems must analyze for Cryptosporidium using Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA, 2005, United States...

  12. Analysis of environmental contamination resulting from catastrophic incidents: part 2. Building laboratory capability by selecting and developing analytical methodologies.

    Science.gov (United States)

    Magnuson, Matthew; Campisano, Romy; Griggs, John; Fitz-James, Schatzi; Hall, Kathy; Mapp, Latisha; Mullins, Marissa; Nichols, Tonya; Shah, Sanjiv; Silvestri, Erin; Smith, Terry; Willison, Stuart; Ernst, Hiba

    2014-11-01

    Catastrophic incidents can generate a large number of samples of analytically diverse types, including forensic, clinical, environmental, food, and others. Environmental samples include water, wastewater, soil, air, urban building and infrastructure materials, and surface residue. Such samples may arise not only from contamination from the incident but also from the multitude of activities surrounding the response to the incident, including decontamination. This document summarizes a range of activities to help build laboratory capability in preparation for sample analysis following a catastrophic incident, including selection and development of fit-for-purpose analytical methods for chemical, biological, and radiological contaminants. Fit-for-purpose methods are those which have been selected to meet project specific data quality objectives. For example, methods could be fit for screening contamination in the early phases of investigation of contamination incidents because they are rapid and easily implemented, but those same methods may not be fit for the purpose of remediating the environment to acceptable levels when a more sensitive method is required. While the exact data quality objectives defining fitness-for-purpose can vary with each incident, a governing principle of the method selection and development process for environmental remediation and recovery is based on achieving high throughput while maintaining high quality analytical results. This paper illustrates the result of applying this principle, in the form of a compendium of analytical methods for contaminants of interest. The compendium is based on experience with actual incidents, where appropriate and available. This paper also discusses efforts aimed at adaptation of existing methods to increase fitness-for-purpose and development of innovative methods when necessary. The contaminants of interest are primarily those potentially released through catastrophes resulting from malicious activity

  13. 40 CFR 141.89 - Analytical methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Analytical methods. 141.89 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Control of Lead and Copper § 141.89 Analytical methods. (a... shall be conducted with the methods in § 141.23(k)(1). (1) Analyses for alkalinity, calcium...

  14. Analytical Methodologies for the Determination of Endocrine Disrupting Compounds in Biological and Environmental Samples

    Directory of Open Access Journals (Sweden)

    Zoraida Sosa-Ferrera

    2013-01-01

    Full Text Available Endocrine-disruptor compounds (EDCs can mimic natural hormones and produce adverse effects in the endocrine functions by interacting with estrogen receptors. EDCs include both natural and synthetic chemicals, such as hormones, personal care products, surfactants, and flame retardants, among others. EDCs are characterised by their ubiquitous presence at trace-level concentrations and their wide diversity. Since the discovery of the adverse effects of these pollutants on wildlife and human health, analytical methods have been developed for their qualitative and quantitative determination. In particular, mass-based analytical methods show excellent sensitivity and precision for their quantification. This paper reviews recently published analytical methodologies for the sample preparation and for the determination of these compounds in different environmental and biological matrices by liquid chromatography coupled with mass spectrometry. The various sample preparation techniques are compared and discussed. In addition, recent developments and advances in this field are presented.

  15. SRC-I demonstration plant analytical laboratory methods manual. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Klusaritz, M.L.; Tewari, K.C.; Tiedge, W.F.; Skinner, R.W.; Znaimer, S.

    1983-03-01

    This manual is a compilation of analytical procedures required for operation of a Solvent-Refined Coal (SRC-I) demonstration or commercial plant. Each method reproduced in full includes a detailed procedure, a list of equipment and reagents, safety precautions, and, where possible, a precision statement. Procedures for the laboratory's environmental and industrial hygiene modules are not included. Required American Society for Testing and Materials (ASTM) methods are cited, and ICRC's suggested modifications to these methods for handling coal-derived products are provided.

  16. Nuclear analytical methods in the life sciences

    NARCIS (Netherlands)

    de Goeij, J.J.M.

    1994-01-01

    A survey is given of various nuclear analytical methods. The type of analytical information obtainable and advantageous features for application in the life sciences are briefly indicated. These features are: physically different basis of the analytical method, isotopic rather than elemental

  17. Use of nuclear and related analytical techniques in environmental research as exemplified by selected air pollution studies

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Jeran, Z.; Stropnik, B.; Svetina, M.

    2000-01-01

    Among nuclear and nuclear related analytical techniques, neutron activation analysis and X-ray fluorescence spectrometry proved to be particularly useful for environmental studies owing to their nondestructive character and multi element capability. This paper emphasizes their importance among other multielement analytical methods by discussing their specific role due to specific physics basis, quite different to other destructive non-nuclear methods, and by summarizing results obtained in several studies related to air pollution research, including analyses of airborne particulate matter, water samples, lichens and mosses. (author)

  18. Environmental Contaminants, Metabolites, Cells, Organ Tissues, and Water: All in a Day’s Work at the EPA Analytical Chemistry Research Core

    Science.gov (United States)

    The talk will highlight key aspects and results of analytical methods the EPA National Health and Environmental Effects Research Laboratory (NHEERL) Analytical Chemistry Research Core (ACRC) develops and uses to provide data on disposition, metabolism, and effects of environmenta...

  19. Abstracts book of 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements

    International Nuclear Information System (INIS)

    1995-01-01

    The 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements has been held in Poznan 27-28 April 1995. The new versions of analytical methods have been presented for quantitative determination of trace elements in biological, environmental and geological materials. Also the number of special techniques for sample preparation enables achievement the best precision of analytical results have been shown and discussed

  20. Problem Formulation in Knowledge Discovery via Data Analytics (KDDA) for Environmental Risk Management.

    Science.gov (United States)

    Li, Yan; Thomas, Manoj; Osei-Bryson, Kweku-Muata; Levy, Jason

    2016-12-15

    With the growing popularity of data analytics and data science in the field of environmental risk management, a formalized Knowledge Discovery via Data Analytics (KDDA) process that incorporates all applicable analytical techniques for a specific environmental risk management problem is essential. In this emerging field, there is limited research dealing with the use of decision support to elicit environmental risk management (ERM) objectives and identify analytical goals from ERM decision makers. In this paper, we address problem formulation in the ERM understanding phase of the KDDA process. We build a DM³ ontology to capture ERM objectives and to inference analytical goals and associated analytical techniques. A framework to assist decision making in the problem formulation process is developed. It is shown how the ontology-based knowledge system can provide structured guidance to retrieve relevant knowledge during problem formulation. The importance of not only operationalizing the KDDA approach in a real-world environment but also evaluating the effectiveness of the proposed procedure is emphasized. We demonstrate how ontology inferencing may be used to discover analytical goals and techniques by conceptualizing Hazardous Air Pollutants (HAPs) exposure shifts based on a multilevel analysis of the level of urbanization (and related economic activity) and the degree of Socio-Economic Deprivation (SED) at the local neighborhood level. The HAPs case highlights not only the role of complexity in problem formulation but also the need for integrating data from multiple sources and the importance of employing appropriate KDDA modeling techniques. Challenges and opportunities for KDDA are summarized with an emphasis on environmental risk management and HAPs.

  1. Problem Formulation in Knowledge Discovery via Data Analytics (KDDA) for Environmental Risk Management

    Science.gov (United States)

    Li, Yan; Thomas, Manoj; Osei-Bryson, Kweku-Muata; Levy, Jason

    2016-01-01

    With the growing popularity of data analytics and data science in the field of environmental risk management, a formalized Knowledge Discovery via Data Analytics (KDDA) process that incorporates all applicable analytical techniques for a specific environmental risk management problem is essential. In this emerging field, there is limited research dealing with the use of decision support to elicit environmental risk management (ERM) objectives and identify analytical goals from ERM decision makers. In this paper, we address problem formulation in the ERM understanding phase of the KDDA process. We build a DM3 ontology to capture ERM objectives and to inference analytical goals and associated analytical techniques. A framework to assist decision making in the problem formulation process is developed. It is shown how the ontology-based knowledge system can provide structured guidance to retrieve relevant knowledge during problem formulation. The importance of not only operationalizing the KDDA approach in a real-world environment but also evaluating the effectiveness of the proposed procedure is emphasized. We demonstrate how ontology inferencing may be used to discover analytical goals and techniques by conceptualizing Hazardous Air Pollutants (HAPs) exposure shifts based on a multilevel analysis of the level of urbanization (and related economic activity) and the degree of Socio-Economic Deprivation (SED) at the local neighborhood level. The HAPs case highlights not only the role of complexity in problem formulation but also the need for integrating data from multiple sources and the importance of employing appropriate KDDA modeling techniques. Challenges and opportunities for KDDA are summarized with an emphasis on environmental risk management and HAPs. PMID:27983713

  2. Improved analytical sensitivity for uranium and plutonium in environmental samples: Cavity ion source thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Ingeneri, Kristofer; Riciputi, L.

    2001-01-01

    Following successful field trials, environmental sampling has played a central role as a routine part of safeguards inspections since early 1996 to verify declared and to detect undeclared activity. The environmental sampling program has brought a new series of analytical challenges, and driven a need for advances in verification technology. Environmental swipe samples are often extremely low in concentration of analyte (ng level or lower), yet the need to analyze these samples accurately and precisely is vital, particularly for the detection of undeclared nuclear activities. Thermal ionization mass spectrometry (TIMS) is the standard method of determining isotope ratios of uranium and plutonium in the environmental sampling program. TIMS analysis typically employs 1-3 filaments to vaporize and ionize the sample, and the ions are mass separated and analyzed using magnetic sector instruments due to their high mass resolution and high ion transmission. However, the ionization efficiency (the ratio of material present to material actually detected) of uranium using a standard TIMS instrument is low (0.2%), even under the best conditions. Increasing ionization efficiency by even a small amount would have a dramatic impact for safeguards applications, allowing both improvements in analytical precision and a significant decrease in the amount of uranium and plutonium required for analysis, increasing the sensitivity of environmental sampling

  3. Nuclear analytical methods: Past, present and future

    International Nuclear Information System (INIS)

    Becker, D.A.

    1996-01-01

    The development of nuclear analytical methods as an analytical tool began in 1936 with the publication of the first paper on neutron activation analysis (NAA). This year, 1996, marks the 60th anniversary of that event. This paper attempts to look back at the nuclear analytical methods of the past, to look around and to see where the technology is right now, and finally, to look ahead to try and see where nuclear methods as an analytical technique (or as a group of analytical techniques) will be going in the future. The general areas which the author focuses on are: neutron activation analysis; prompt gamma neutron activation analysis (PGNAA); photon activation analysis (PAA); charged-particle activation analysis (CPAA)

  4. Study of comparison between neutron activation analysis and the other analytical methods

    International Nuclear Information System (INIS)

    Nagatsuka, Sumiko

    1986-01-01

    The neutron activation analysis (NAA) is compared with other analytical methods based on various data. It is concluded that NAA is most frequently used for the analysis of NBS environmental standard samples. NAA is suitable for the analysis of trace elements contained in environmental samples since non-destructive quantitative determination can be carried out simultaneously for different elements. NAA and XRF are the only methods which can be used for analyzing oil samples. This also indicates the usefulness of non-destructive techniques. In any standard sample, NAA can achieve a high accuracy for more than 90 % of the elements contained. On the other hand, the accuracy varies depending on the type of sample in the case of the other analytical methods examined. Regarding the prescision, NAA for any standard sample is the smallest in the proportion of the number of elements determined with C.V. (coefficient of variation) of less than 10 % to the total number of elements contained. However, the total number of elements which can be determined by NAA with C.V. of less than 10 % is greater than that by any of the other four methods examined. It should be noticed that there are some elements which can be determined only by NAA. (Nogami, K.)

  5. A New Project-Based Lab for Undergraduate Environmental and Analytical Chemistry

    Science.gov (United States)

    Adami, Gianpiero

    2006-01-01

    A new project-based lab was developed for third year undergraduate chemistry students based on real world applications. The experience suggests that the total analytical procedure (TAP) project offers a stimulating alternative for delivering science skills and developing a greater interest for analytical chemistry and environmental sciences and…

  6. Reactor Section standard analytical methods. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Sowden, D.

    1954-07-01

    the Standard Analytical Methods manual was prepared for the purpose of consolidating and standardizing all current analytical methods and procedures used in the Reactor Section for routine chemical analyses. All procedures are established in accordance with accepted practice and the general analytical methods specified by the Engineering Department. These procedures are specifically adapted to the requirements of the water treatment process and related operations. The methods included in this manual are organized alphabetically within the following five sections which correspond to the various phases of the analytical control program in which these analyses are to be used: water analyses, essential material analyses, cotton plug analyses boiler water analyses, and miscellaneous control analyses.

  7. Problem Formulation in Knowledge Discovery via Data Analytics (KDDA for Environmental Risk Management

    Directory of Open Access Journals (Sweden)

    Yan Li

    2016-12-01

    Full Text Available With the growing popularity of data analytics and data science in the field of environmental risk management, a formalized Knowledge Discovery via Data Analytics (KDDA process that incorporates all applicable analytical techniques for a specific environmental risk management problem is essential. In this emerging field, there is limited research dealing with the use of decision support to elicit environmental risk management (ERM objectives and identify analytical goals from ERM decision makers. In this paper, we address problem formulation in the ERM understanding phase of the KDDA process. We build a DM3 ontology to capture ERM objectives and to inference analytical goals and associated analytical techniques. A framework to assist decision making in the problem formulation process is developed. It is shown how the ontology-based knowledge system can provide structured guidance to retrieve relevant knowledge during problem formulation. The importance of not only operationalizing the KDDA approach in a real-world environment but also evaluating the effectiveness of the proposed procedure is emphasized. We demonstrate how ontology inferencing may be used to discover analytical goals and techniques by conceptualizing Hazardous Air Pollutants (HAPs exposure shifts based on a multilevel analysis of the level of urbanization (and related economic activity and the degree of Socio-Economic Deprivation (SED at the local neighborhood level. The HAPs case highlights not only the role of complexity in problem formulation but also the need for integrating data from multiple sources and the importance of employing appropriate KDDA modeling techniques. Challenges and opportunities for KDDA are summarized with an emphasis on environmental risk management and HAPs.

  8. Possibilities of Utilizing the Method of Analytical Hierarchy Process Within the Strategy of Corporate Social Business

    Science.gov (United States)

    Drieniková, Katarína; Hrdinová, Gabriela; Naňo, Tomáš; Sakál, Peter

    2010-01-01

    The paper deals with the analysis of the theory of corporate social responsibility, risk management and the exact method of analytic hierarchic process that is used in the decision-making processes. The Chapters 2 and 3 focus on presentation of the experience with the application of the method in formulating the stakeholders' strategic goals within the Corporate Social Responsibility (CSR) and simultaneously its utilization in minimizing the environmental risks. The major benefit of this paper is the application of Analytical Hierarchy Process (AHP).

  9. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index.

    Science.gov (United States)

    Płotka-Wasylka, J

    2018-05-01

    A new means for assessing analytical protocols relating to green analytical chemistry attributes has been developed. The new tool, called GAPI (Green Analytical Procedure Index), evaluates the green character of an entire analytical methodology, from sample collection to final determination, and was created using such tools as the National Environmental Methods Index (NEMI) or Analytical Eco-Scale to provide not only general but also qualitative information. In GAPI, a specific symbol with five pentagrams can be used to evaluate and quantify the environmental impact involved in each step of an analytical methodology, mainly from green through yellow to red depicting low, medium to high impact, respectively. The proposed tool was used to evaluate analytical procedures applied in the determination of biogenic amines in wine samples, and polycyclic aromatic hydrocarbon determination by EPA methods. GAPI tool not only provides an immediately perceptible perspective to the user/reader but also offers exhaustive information on evaluated procedures. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. MS-Based Analytical Techniques: Advances in Spray-Based Methods and EI-LC-MS Applications

    Science.gov (United States)

    Medina, Isabel; Cappiello, Achille; Careri, Maria

    2018-01-01

    Mass spectrometry is the most powerful technique for the detection and identification of organic compounds. It can provide molecular weight information and a wealth of structural details that give a unique fingerprint for each analyte. Due to these characteristics, mass spectrometry-based analytical methods are showing an increasing interest in the scientific community, especially in food safety, environmental, and forensic investigation areas where the simultaneous detection of targeted and nontargeted compounds represents a key factor. In addition, safety risks can be identified at the early stage through online and real-time analytical methodologies. In this context, several efforts have been made to achieve analytical instrumentation able to perform real-time analysis in the native environment of samples and to generate highly informative spectra. This review article provides a survey of some instrumental innovations and their applications with particular attention to spray-based MS methods and food analysis issues. The survey will attempt to cover the state of the art from 2012 up to 2017.

  11. HTGR analytical methods and design verification

    International Nuclear Information System (INIS)

    Neylan, A.J.; Northup, T.E.

    1982-05-01

    Analytical methods for the high-temperature gas-cooled reactor (HTGR) include development, update, verification, documentation, and maintenance of all computer codes for HTGR design and analysis. This paper presents selected nuclear, structural mechanics, seismic, and systems analytical methods related to the HTGR core. This paper also reviews design verification tests in the reactor core, reactor internals, steam generator, and thermal barrier

  12. 75 FR 49930 - Stakeholder Meeting Regarding Re-Evaluation of Currently Approved Total Coliform Analytical Methods

    Science.gov (United States)

    2010-08-16

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9190-2] Stakeholder Meeting Regarding Re-Evaluation of... conferences during which the Agency will have a technical dialogue with stakeholders regarding re-evaluation of currently approved Total Coliform Rule (TCR) analytical methods. At these meetings, stakeholders...

  13. New trends in the analytical determination of emerging contaminants and their transformation products in environmental waters.

    Science.gov (United States)

    Agüera, Ana; Martínez Bueno, María Jesús; Fernández-Alba, Amadeo R

    2013-06-01

    Since the so-called emerging contaminants were established as a new group of pollutants of environmental concern, a great effort has been devoted to the knowledge of their distribution, fate and effects in the environment. After more than 20 years of work, a significant improvement in knowledge about these contaminants has been achieved, but there is still a large gap of information on the growing number of new potential contaminants that are appearing and especially of their unpredictable transformation products. Although the environmental problem arising from emerging contaminants must be addressed from an interdisciplinary point of view, it is obvious that analytical chemistry plays an important role as the first step of the study, as it allows establishing the presence of chemicals in the environment, estimate their concentration levels, identify sources and determine their degradation pathways. These tasks involve serious difficulties requiring different analytical solutions adjusted to purpose. Thus, the complexity of the matrices requires highly selective analytical methods; the large number and variety of compounds potentially present in the samples demands the application of wide scope methods; the low concentrations at which these contaminants are present in the samples require a high detection sensitivity, and high demands on the confirmation and high structural information are needed for the characterisation of unknowns. New developments on analytical instrumentation have been applied to solve these difficulties. Furthermore and not less important has been the development of new specific software packages intended for data acquisition and, in particular, for post-run analysis. Thus, the use of sophisticated software tools has allowed successful screening analysis, determining several hundreds of analytes, and assisted in the structural elucidation of unknown compounds in a timely manner.

  14. Voltammetric technique, a panacea for analytical examination of environmental samples

    International Nuclear Information System (INIS)

    Zahir, E.; Mohiuddin, S.; Naqvi, I.I.

    2012-01-01

    Voltammetric methods for trace metal analysis in environmental samples of marine origin like mangrove, sediments and shrimps are generally recommended. Three different electro-analytical techniques i.e. polarography, anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (ADSV) have been used. Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ and Mn/sub 2/+ were determined through ASV, Cr/sub 6/+ was analyzed by ADSV and Fe/sub 2/+, Zn/sub 2/+, Ni/sub 2/+ and Co/sub 2/+ were determined through polarography. Out of which pairs of Fe/sub 2/+Zn/sub 2/+ and Ni/sub 2/+Co/sub 2/+ were determined in two separate runs while Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ were analyzed in single run of ASV. Sensitivity and speciation capabilities of voltammetric methods have been employed. Analysis conditions were optimized that includes selection of supporting electrolyte, pH, working electrodes, sweep rate etc. Stripping voltammetry was adopted for analysis at ultra trace levels. Statistical parameters for analytical method development like selectivity factor, interference, repeatability (0.0065-0.130 macro g/g), reproducibility (0.08125-1.625 macro g/g), detection limits (0.032-5.06 macro g/g), limits of quantification (0.081-12.652 macro g/g), sensitivities (5.636-2.15 nA mL macro g-1) etc. were also determined. The percentage recoveries were found in between 95-105% using certified reference materials. Real samples of complex marine environment from Karachi coastline were also analyzed. The standard addition method was employed where any matrix effect was evidenced. (author)

  15. Method for effective usage of Google Analytics tools

    Directory of Open Access Journals (Sweden)

    Ирина Николаевна Егорова

    2016-01-01

    Full Text Available Modern Google Analytics tools have been investigated against effective attraction channels for users and bottlenecks detection. Conducted investigation allowed to suggest modern method for effective usage of Google Analytics tools. The method is based on main traffic indicators analysis, as well as deep analysis of goals and their consecutive tweaking. Method allows to increase website conversion and might be useful for SEO and Web analytics specialists

  16. Analytical methodologies for aluminium speciation in environmental and biological samples--a review.

    Science.gov (United States)

    Bi, S P; Yang, X D; Zhang, F P; Wang, X L; Zou, G W

    2001-08-01

    It is recognized that aluminium (Al) is a potential environmental hazard. Acidic deposition has been linked to increased Al concentrations in natural waters. Elevated levels of Al might have serious consequences for biological communities. Of particular interest is the speciation of Al in aquatic environments, because Al toxicity depends on its forms and concentrations. In this paper, advances in analytical methodologies for Al speciation in environmental and biological samples during the past five years are reviewed. Concerns about the specific problems of Al speciation and highlights of some important methods are elucidated in sections devoted to hybrid techniques (HPLC or FPLC coupled with ET-AAS, ICP-AES, or ICP-MS), flow-injection analysis (FIA), nuclear magnetic resonance (27Al NMR), electrochemical analysis, and computer simulation. More than 130 references are cited.

  17. Nuclear analytical chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D.; Forkman, B.; Persson, B.

    1984-01-01

    This book covers the general theories and techniques of nuclear chemical analysis, directed at applications in analytical chemistry, nuclear medicine, radiophysics, agriculture, environmental sciences, geological exploration, industrial process control, etc. The main principles of nuclear physics and nuclear detection on which the analysis is based are briefly outlined. An attempt is made to emphasise the fundamentals of activation analysis, detection and activation methods, as well as their applications. The book provides guidance in analytical chemistry, agriculture, environmental and biomedical sciences, etc. The contents include: the nuclear periodic system; nuclear decay; nuclear reactions; nuclear radiation sources; interaction of radiation with matter; principles of radiation detectors; nuclear electronics; statistical methods and spectral analysis; methods of radiation detection; neutron activation analysis; charged particle activation analysis; photon activation analysis; sample preparation and chemical separation; nuclear chemical analysis in biological and medical research; the use of nuclear chemical analysis in the field of criminology; nuclear chemical analysis in environmental sciences, geology and mineral exploration; and radiation protection.

  18. Nuclear analytical chemistry

    International Nuclear Information System (INIS)

    Brune, D.; Forkman, B.; Persson, B.

    1984-01-01

    This book covers the general theories and techniques of nuclear chemical analysis, directed at applications in analytical chemistry, nuclear medicine, radiophysics, agriculture, environmental sciences, geological exploration, industrial process control, etc. The main principles of nuclear physics and nuclear detection on which the analysis is based are briefly outlined. An attempt is made to emphasise the fundamentals of activation analysis, detection and activation methods, as well as their applications. The book provides guidance in analytical chemistry, agriculture, environmental and biomedical sciences, etc. The contents include: the nuclear periodic system; nuclear decay; nuclear reactions; nuclear radiation sources; interaction of radiation with matter; principles of radiation detectors; nuclear electronics; statistical methods and spectral analysis; methods of radiation detection; neutron activation analysis; charged particle activation analysis; photon activation analysis; sample preparation and chemical separation; nuclear chemical analysis in biological and medical research; the use of nuclear chemical analysis in the field of criminology; nuclear chemical analysis in environmental sciences, geology and mineral exploration; and radiation protection

  19. International conference on nuclear analytical methods in the life sciences (NAMLS) (abstracts)

    International Nuclear Information System (INIS)

    1999-01-01

    The International Conference on Nuclear Analytical Methods in the Life Sciences (NAMLS) was hold on October 26-30, 1998 in Beijing, China, which was organized by China Institute of Atomic Energy in Cooperation with IAEA, National Science Foundation of China, China National Nuclear Cooperation, Chinese Academy of Sciences, Institute of High Energy Physics, Shanghai Institute for Nuclear Research, Chinese Nuclear Society, Nuclear Physics Society of China and Nuclear Chemistry Society of China. the contents of this Conference include: 1. QA-QC and CRM studies; 2. Elemental speciation and localization; 3. Health-related environmental studies; 4. Recent development in nuclear and related analytical techniques; 5. Trace elements in health and diseases; 6. Miscellaneous applications of NAT in the life sciences

  20. Application of system reliability analytical method, GO-FLOW

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi; Fukuto, Junji; Mitomo, Nobuo; Miyazaki, Keiko; Matsukura, Hiroshi; Kobayashi, Michiyuki

    1999-01-01

    The Ship Research Institute proceed a developmental study on GO-FLOW method with various advancing functionalities for the system reliability analysis method occupying main parts of PSA (Probabilistic Safety Assessment). Here was attempted to intend to upgrade functionality of the GO-FLOW method, to develop an analytical function integrated with dynamic behavior analytical function, physical behavior and probable subject transfer, and to prepare a main accident sequence picking-out function. In 1997 fiscal year, in dynamic event-tree analytical system, an analytical function was developed by adding dependency between headings. In simulation analytical function of the accident sequence, main accident sequence of MRX for improved ship propulsion reactor became possible to be covered perfectly. And, input data for analysis was prepared with a function capable easily to set by an analysis operator. (G.K.)

  1. Cost-effective and simple solutions for environmental pollution problems by electrochemical methods

    International Nuclear Information System (INIS)

    Ahmed, R.

    1997-01-01

    Environmental pollution is a worldwide problem and has increased significantly with industrialization, urbanization and population growth and is effecting quality of our air, land and water resources. Pollutants include heavy metals, organic toxic and reactive compounds and toxic gases. Major problems in environmental pollution are monitoring and remediation. Now pollutants include such wide range of elements, compounds and gases and normally one needs a whole range of costly analytical techniques to analyse all the pollutants which only very few institutes can afford to purchased. Equipment for electro analytical techniques are much cheaper than most of the other analytical techniques and are also sensitive and accurate for the analysis of nearly the whole range of pollutants including heavy metal. organic reactive compounds, inorganic elements and compounds and toxic gases. application of electrochemical methods for the analysis of different pollutants are reviewed. after monitoring, remediation in the most important aspect of environmental pollution control. Best way could be to treat the pollutants from different industries in such a way that either these are removed from the waste or converted in to non-toxic compounds before their release into the environment. Among all the other treatment methods, electrochemical methods of utilizing the electron as a clean chemical regent are very attractive. Electrodes in electrochemical reactors are abundantly use for the removal and recycling of toxic metals like Cd, Cu, Ni, Pb, Cr and Zn from the industrial waste after electrodeposition. Electrochemical reactors are also being used for electro oxidation of cyanides and other toxic organic compounds into non-toxic species. Such reactors can, in principal, be applied to any environmental pollution problem where the pollutant can either be electro-reduced or oxidized. Different types of electrochemical reactors are discussed, with a view, of their envisaged used for

  2. Nonlinear ordinary differential equations analytical approximation and numerical methods

    CERN Document Server

    Hermann, Martin

    2016-01-01

    The book discusses the solutions to nonlinear ordinary differential equations (ODEs) using analytical and numerical approximation methods. Recently, analytical approximation methods have been largely used in solving linear and nonlinear lower-order ODEs. It also discusses using these methods to solve some strong nonlinear ODEs. There are two chapters devoted to solving nonlinear ODEs using numerical methods, as in practice high-dimensional systems of nonlinear ODEs that cannot be solved by analytical approximate methods are common. Moreover, it studies analytical and numerical techniques for the treatment of parameter-depending ODEs. The book explains various methods for solving nonlinear-oscillator and structural-system problems, including the energy balance method, harmonic balance method, amplitude frequency formulation, variational iteration method, homotopy perturbation method, iteration perturbation method, homotopy analysis method, simple and multiple shooting method, and the nonlinear stabilized march...

  3. Palladium emissions in the environment: analytical methods, environmental assessment and health effects

    National Research Council Canada - National Science Library

    Alt, Friedrich; Zereini, Fathi

    2006-01-01

    ... (Eds)). But there is a clear lack of information concerning palladium. It is very important to condense the present state of research findings from emission to potential health risks for the environment and humans. Very important is the chapter about analytical determination of palladium, which shows clearly the problems of several analytic...

  4. Workshop on Analytical Methods in Statistics

    CERN Document Server

    Jurečková, Jana; Maciak, Matúš; Pešta, Michal

    2017-01-01

    This volume collects authoritative contributions on analytical methods and mathematical statistics. The methods presented include resampling techniques; the minimization of divergence; estimation theory and regression, eventually under shape or other constraints or long memory; and iterative approximations when the optimal solution is difficult to achieve. It also investigates probability distributions with respect to their stability, heavy-tailness, Fisher information and other aspects, both asymptotically and non-asymptotically. The book not only presents the latest mathematical and statistical methods and their extensions, but also offers solutions to real-world problems including option pricing. The selected, peer-reviewed contributions were originally presented at the workshop on Analytical Methods in Statistics, AMISTAT 2015, held in Prague, Czech Republic, November 10-13, 2015.

  5. Radiochemistry methods in DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Fadeff, S.K.; Goheen, S.C.

    1994-08-01

    Current standard sources of radiochemistry methods are often inappropriate for use in evaluating US Department of Energy environmental and waste management (DOE/EW) samples. Examples of current sources include EPA, ASTM, Standard Methods for the Examination of Water and Wastewater and HASL-300. Applicability of these methods is limited to specific matrices (usually water), radiation levels (usually environmental levels), and analytes (limited number). Radiochemistry methods in DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) attempt to fill the applicability gap that exists between standard methods and those needed for DOE/EM activities. The Radiochemistry chapter in DOE Methods includes an ''analysis and reporting'' guidance section as well as radiochemistry methods. A basis for identifying the DOE/EM radiochemistry needs is discussed. Within this needs framework, the applicability of standard methods and targeted new methods is identified. Sources of new methods (consolidated methods from DOE laboratories and submissions from individuals) and the methods review process will be discussed. The processes involved in generating consolidated methods add editing individually submitted methods will be compared. DOE Methods is a living document and continues to expand by adding various kinds of methods. Radiochemistry methods are highlighted in this paper. DOE Methods is intended to be a resource for methods applicable to DOE/EM problems. Although it is intended to support DOE, the guidance and methods are not necessarily exclusive to DOE. The document is available at no cost through the Laboratory Management Division of DOE, Office of Technology Development

  6. 40 CFR 141.25 - Analytical methods for radioactivity.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Analytical methods for radioactivity... § 141.25 Analytical methods for radioactivity. (a) Analysis for the following contaminants shall be conducted to determine compliance with § 141.66 (radioactivity) in accordance with the methods in the...

  7. Radiochemistry methods in DOE Methods for Evaluating Environmental and Waste Management Samples: Addressing new challenges

    International Nuclear Information System (INIS)

    Fadeff, S.K.; Goheen, S.C.; Riley, R.G.

    1994-01-01

    Radiochemistry methods in Department of Energy Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) add to the repertoire of other standard methods in support of U.S. Department of Energy environmental restoration and waste management (DOE/EM) radiochemical characterization activities. Current standard sources of radiochemistry methods are not always applicable for evaluating DOE/EM samples. Examples of current sources include those provided by the US Environmental Protection Agency, the American Society for Testing and Materials, Standard Methods for the Examination of Water and Wastewater, and Environmental Measurements Laboratory Procedures Manual (HASL-300). The applicability of these methods is generally limited to specific matrices (usually water), low-level radioactive samples, and a limited number of analytes. DOE Methods complements these current standard methods by addressing the complexities of EM characterization needs. The process for determining DOE/EM radiochemistry characterization needs is discussed. In this context of DOE/EM needs, the applicability of other sources of standard radiochemistry methods is defined, and gaps in methodology are identified. Current methods in DOE Methods and the EM characterization needs they address are discussed. Sources of new methods and the methods incorporation process are discussed. The means for individuals to participate in (1) identification of DOE/EM needs, (2) the methods incorporation process, and (3) submission of new methods are identified

  8. Analytical methods used at model facility

    International Nuclear Information System (INIS)

    Wing, N.S.

    1984-01-01

    A description of analytical methods used at the model LEU Fuel Fabrication Facility is presented. The methods include gravimetric uranium analysis, isotopic analysis, fluorimetric analysis, and emission spectroscopy

  9. Analytical methods for heat transfer and fluid flow problems

    CERN Document Server

    Weigand, Bernhard

    2015-01-01

    This book describes useful analytical methods by applying them to real-world problems rather than solving the usual over-simplified classroom problems. The book demonstrates the applicability of analytical methods even for complex problems and guides the reader to a more intuitive understanding of approaches and solutions. Although the solution of Partial Differential Equations by numerical methods is the standard practice in industries, analytical methods are still important for the critical assessment of results derived from advanced computer simulations and the improvement of the underlying numerical techniques. Literature devoted to analytical methods, however, often focuses on theoretical and mathematical aspects and is therefore useless to most engineers. Analytical Methods for Heat Transfer and Fluid Flow Problems addresses engineers and engineering students. The second edition has been updated, the chapters on non-linear problems and on axial heat conduction problems were extended. And worked out exam...

  10. Analytical procedures for the determination of strontium radionuclides in environmental materials

    International Nuclear Information System (INIS)

    Harvey, B.R.; Ibbett, R.D.; Lovett, M.B.; Williams, K.J.

    1989-01-01

    As part of its statutory role in the authorisation, monitoring and research relating to radioactive wastes discharged into the aquatic environment, the Aquatic Environment Protection Division of the Directorate of Fisheries Research (DFR), Lowestoft routinely carries out analyses for a substantial number of radionuclides in a wide range of environmental materials. The Ministry of a Agriculture, Fisheries and Food has for many years required information about the concentrations of strontium radionuclides in waters, sediments and biological materials. There are not absolute standard methods for such radiochemical analysis; indeed none are required because methodology is continually developing. A very considerable amount of expertise has been developed in the analysis of radiostrontium at the Laboratory since the late 1950s, when detailed analysis first commenced, and the procedures described in this report have been developed and tested over a long period of time with a view to achieving the highest analytical quality. Full details of the practical, analytical and computational procedures, as currently used, are given in the Appendix. (author)

  11. PFAS methods and guidance for sampling and analyzing water and other environmental media (Technical Brief)

    Science.gov (United States)

    EPA's methods for analyzing PFAS in environmental media are in various stages of development. This fact sheet summarizes EPA's analytical methods development for groundwater, surface water, wastewater, and solids, including soils, sediments, and biosolids

  12. Requirements for quality control of analytical data for the Environmental Restoration Program

    International Nuclear Information System (INIS)

    Engels, J.

    1992-12-01

    The Environmental Restoration (ER) Program was established for the investigation and remediation of inactive US Department of Energy (DOE) sites and facilities that have been declared surplus in terms of their previous uses. The purpose of this document is to Specify ER requirements for quality control (QC) of analytical data. Activities throughout all phases of the investigation may affect the quality of the final data product, thus are subject to control specifications. Laboratory control is emphasized in this document, and field concerns will be addressed in a companion document Energy Systems, in its role of technical coordinator and at the request of DOE-OR, extends the application of these requirements to all participants in ER activities. Because every instance and concern may not be addressed in this document, participants are encouraged to discuss any questions with the ER Quality Assurance (QA) Office, the Analytical Environmental Support Group (AESG), or the Analytical Project Office (APO)

  13. A Comparison of Two Approaches for the Ruggedness Testing of an Analytical Method

    International Nuclear Information System (INIS)

    Maestroni, Britt

    2016-01-01

    As part of an initiative under the “Red Analitica de Latino America y el Caribe” (RALACA) network the FAO/IAEA Food and Environmental Protection Laboratory validated a multi-residue method for pesticides in potato. One of the parameters to be assessed was the intra laboratory robustness or ruggedness. The objective of this work was to implement a worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method. As a conclusion to this study, it is evident that there is a need for harmonization of the definition of the terms robustness/ruggedness, the limits, the methodology and the statistical treatment of the generated data. A worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method will soon be posted on the RALACA website (www.red-ralaca.net). This study was carried out with collaborators from LVA (Austria), University of Antwerp (Belgium), University of Leuwen (The Netherlands), Universidad de la Republica (Uruguay) and Agilent technologies.

  14. Functional Analytic Multisensory Environmental Therapy for People with Dementia

    OpenAIRE

    Staal, Jason A.

    2012-01-01

    This paper introduces Functional Analytic Multisensory Environmental Therapy (FAMSET) for use with elders with dementia while using a multisensory environment/snoezelen room. The model introduces behavioral theory and practice to the multisensory environment treatment, addressing assessment, and, within session techniques, integrating behavioral interventions with emotion-oriented care. A modular approach is emphasized to delineate different treatment phases for multisensory environment thera...

  15. The environmental evaluation of substation based on the fuzzy analytic hierarchy process

    Science.gov (United States)

    Qian, Wenxiao; Zuo, Xiujiang; Chen, Yuandong; Ye, Ming; Fang, Zhankai; Yang, Fan

    2018-02-01

    This paper studies on the different influences on the environment of the substations and puts forward an index system of environmental protection through the fuzzy analytic hierarchy process. A comprehensive environmental evaluation on a substation is carried out through investigation and measurement of the current environmental factors, and the statistical data has validated the effectiveness and feasibility of this evaluation index system. The results indicate that the proposed model has high efficiency.

  16. Application of analytic hierarchy process in mine environmental assesment-take Fuxin mines as example

    International Nuclear Information System (INIS)

    Kong Zhizhao; Jiang Xue; Dong Shuangfa; Zhao Zhao

    2012-01-01

    We taking mine environmental assessment work by analytic hierarchy process on the basis of results of remote sensing investigation in Fuxin Mines. Putting forward an assessing system consist of index, method and levels. This system makes the levels by weight percent calculated by judging matrixes. Taking Hebei Mines as an example test the system. It shows that the result by the system is credible and is reasonable. This provides a significant data for the second-mines-plan of Liaoning Province. (authors)

  17. Analytical detection methods for irradiated foods

    International Nuclear Information System (INIS)

    1991-03-01

    The present publication is a review of scientific literature on the analytical identification of foods treated with ionizing radiation and the quantitative determination of absorbed dose of radiation. Because of the extremely low level of chemical changes resulting from irradiation or because of the lack of specificity to irradiation of any chemical changes, a few methods of quantitative determination of absorbed dose have shown promise until now. On the other hand, the present review has identified several possible methods, which could be used, following further research and testing, for the identification of irradiated foods. An IAEA Co-ordinated Research Programme on Analytical Detection Methods for Irradiation Treatment of Food ('ADMIT'), established in 1990, is currently investigating many of the methods cited in the present document. Refs and tab

  18. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  19. A sensitive analytical procedure for monitoring acrylamide in environmental water samples by offline SPE-UPLC/MS/MS.

    Science.gov (United States)

    Togola, Anne; Coureau, Charlotte; Guezennec, Anne-Gwenaëlle; Touzé, Solène

    2015-05-01

    The presence of acrylamide in natural systems is of concern from both environmental and health points of view. We developed an accurate and robust analytical procedure (offline solid phase extraction combined with UPLC/MS/MS) with a limit of quantification (20 ng L(-1)) compatible with toxicity threshold values. The optimized (considering the nature of extraction phases, sampling volumes, and solvent of elution) solid phase extraction (SPE) was validated according to ISO Standard ISO/IEC 17025 on groundwater, surface water, and industrial process water samples. Acrylamide is highly polar, which induces a high variability during the SPE step, therefore requiring the use of C(13)-labeled acrylamide as an internal standard to guarantee the accuracy and robustness of the method (uncertainty about 25 % (k = 2) at limit of quantification level). The specificity of the method and the stability of acrylamide were studied for these environmental media, and it was shown that the method is suitable for measuring acrylamide in environmental studies.

  20. DOE methods compendium

    International Nuclear Information System (INIS)

    Leasure, C.S.

    1992-01-01

    The Department of Energy (DOE) has established an analytical methods compendium development program to integrate its environmental analytical methods. This program is administered through DOE's Laboratory Management Division (EM-563). The primary objective of this program is to assemble a compendium of analytical chemistry methods of known performance for use by all DOE Environmental Restoration and Waste Management program. This compendium will include methods for sampling, field screening, fixed analytical laboratory and mobile analytical laboratory analyses. It will also include specific guidance on the proper selection of appropriate sampling and analytical methods in using specific analytical requirements

  1. A review of analytical techniques for the determination of carbon-14 in environmental samples

    International Nuclear Information System (INIS)

    Milton, G.M.; Brown, R.M.

    1993-11-01

    This report contains a brief summary of analytical techniques commonly used for the determination of radiocarbon in a variety of environmental samples. Details of the applicable procedures developed and tested in the Environmental Research Branch at Chalk River Laboratories are appended

  2. Analytical methods under emergency conditions

    International Nuclear Information System (INIS)

    Sedlet, J.

    1983-01-01

    This lecture discusses methods for the radiochemical determination of internal contamination of the body under emergency conditions, here defined as a situation in which results on internal radioactive contamination are needed quickly. The purpose of speed is to determine the necessity for medical treatment to increase the natural elimination rate. Analytical methods discussed include whole-body counting, organ counting, wound monitoring, and excreta analysis. 12 references

  3. The current preference for the immuno-analytical ELISA method for quantitation of steroid hormones (endocrine disruptor compounds) in wastewater in South Africa.

    Science.gov (United States)

    Manickum, Thavrin; John, Wilson

    2015-07-01

    The availability of national test centers to offer a routine service for analysis and quantitation of some selected steroid hormones [natural estrogens (17-β-estradiol, E2; estrone, E1; estriol, E3), synthetic estrogen (17-α-ethinylestradiol, EE2), androgen (testosterone), and progestogen (progesterone)] in wastewater matrix was investigated; corresponding internationally used chemical- and immuno-analytical test methods were reviewed. The enzyme-linked immunosorbent assay (ELISA) (immuno-analytical technique) was also assessed for its suitability as a routine test method to quantitate the levels of these hormones at a sewage/wastewater treatment plant (WTP) (Darvill, Pietermaritzburg, South Africa), over a 2-year period. The method performance and other relevant characteristics of the immuno-analytical ELISA method were compared to the conventional chemical-analytical methodology, like gas/liquid chromatography-mass spectrometry (GC/LC-MS), and GC-LC/tandem mass spectrometry (MSMS), for quantitation of the steroid hormones in wastewater and environmental waters. The national immuno-analytical ELISA technique was found to be sensitive (LOQ 5 ng/L, LOD 0.2-5 ng/L), accurate (mean recovery 96%), precise (RSD 7-10%), and cost-effective for screening and quantitation of these steroid hormones in wastewater and environmental water matrix. A survey of the most current international literature indicates a fairly equal use of the LC-MS/MS, GC-MS/MS (chemical-analytical), and ELISA (immuno-analytical) test methods for screening and quantitation of the target steroid hormones in both water and wastewater matrix. Internationally, the observed sensitivity, based on LOQ (ng/L), for the steroid estrogens E1, E2, EE2, is, in decreasing order: LC-MSMS (0.08-9.54) > GC-MS (1) > ELISA (5) (chemical-analytical > immuno-analytical). At the national level, the routine, unoptimized chemical-analytical LC-MSMS method was found to lack the required sensitivity for meeting environmental

  4. An environmental pressure index proposal for urban development planning based on the analytic network process

    International Nuclear Information System (INIS)

    Gomez-Navarro, Tomas; Garcia-Melon, Monica; Acuna-Dutra, Silvia; Diaz-Martin, Diego

    2009-01-01

    This paper introduces a new approach to prioritize urban planning projects according to their environmental pressure in an efficient and reliable way. It is based on the combination of three procedures: (i) the use of environmental pressure indicators, (ii) the aggregation of the indicators in an Environmental Pressure Index by means of the Analytic Network Process method (ANP) and (iii) the interpretation of the information obtained from the experts during the decision-making process. The method has been applied to a proposal for urban development of La Carlota airport in Caracas (Venezuela). There are three options which are currently under evaluation. They include a Health Club, a Residential Area and a Theme Park. After a selection process the experts chose the following environmental pressure indicators as ANP criteria for the project life cycle: used land area, population density, energy consumption, water consumption and waste generation. By using goal-oriented questionnaires designed by the authors, the experts determined the importance of the criteria, the relationships among criteria, and the relationships between the criteria and the urban development alternatives. The resulting data showed that water consumption is the most important environmental pressure factor, and the Theme Park project is by far the urban development alternative which exerts the least environmental pressure on the area. The participating experts coincided in appreciating the technique proposed in this paper is useful and, for ranking ordering these alternatives, an improvement from traditional techniques such as environmental impact studies, life-cycle analysis, etc.

  5. Possibilities for decreasing detection limits of analytical methods for determination of transformation products of unsymmetrical dimethylhydrazine in environmental samples

    Directory of Open Access Journals (Sweden)

    Bulat Kenessov

    2015-12-01

    Full Text Available Most rockets of middle and heavy class launched from Kazakhstan, Russia, China and other countries still use highly toxic unsymmetrical dimethylhydrazine (UDMH as a liquid propellant. Study of migration, distribution and accumulation of UDMH transformation products in environment and human health impact assessment of space rocket activity are currently complicated due to the absence of analytical methods allowing detection of trace concentrations of these compounds in analyzed samples. This paper reviews methods and approaches, which can be applied for development of such methods. Detection limits at a part-per-trillion (ppt level may be achieved using most selective and sensitive methods based on gas or liquid chromatography in combination of tandem or high-resolution mass spectrometry. In addition, 1000-fold concentration of samples or integrated sample preparation methods, e.g., dynamic headspace extraction, are required. Special attention during development and application of such methods must be paid to purity of laboratory air, reagents, glassware and analytical instruments.

  6. Statistically qualified neuro-analytic failure detection method and system

    Science.gov (United States)

    Vilim, Richard B.; Garcia, Humberto E.; Chen, Frederick W.

    2002-03-02

    An apparatus and method for monitoring a process involve development and application of a statistically qualified neuro-analytic (SQNA) model to accurately and reliably identify process change. The development of the SQNA model is accomplished in two stages: deterministic model adaption and stochastic model modification of the deterministic model adaptation. Deterministic model adaption involves formulating an analytic model of the process representing known process characteristics, augmenting the analytic model with a neural network that captures unknown process characteristics, and training the resulting neuro-analytic model by adjusting the neural network weights according to a unique scaled equation error minimization technique. Stochastic model modification involves qualifying any remaining uncertainty in the trained neuro-analytic model by formulating a likelihood function, given an error propagation equation, for computing the probability that the neuro-analytic model generates measured process output. Preferably, the developed SQNA model is validated using known sequential probability ratio tests and applied to the process as an on-line monitoring system. Illustrative of the method and apparatus, the method is applied to a peristaltic pump system.

  7. Green analytical chemistry introduction to chloropropanols determination at no economic and analytical performance costs?

    Science.gov (United States)

    Jędrkiewicz, Renata; Orłowski, Aleksander; Namieśnik, Jacek; Tobiszewski, Marek

    2016-01-15

    In this study we perform ranking of analytical procedures for 3-monochloropropane-1,2-diol determination in soy sauces by PROMETHEE method. Multicriteria decision analysis was performed for three different scenarios - metrological, economic and environmental, by application of different weights to decision making criteria. All three scenarios indicate capillary electrophoresis-based procedure as the most preferable. Apart from that the details of ranking results differ for these three scenarios. The second run of rankings was done for scenarios that include metrological, economic and environmental criteria only, neglecting others. These results show that green analytical chemistry-based selection correlates with economic, while there is no correlation with metrological ones. This is an implication that green analytical chemistry can be brought into laboratories without analytical performance costs and it is even supported by economic reasons. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Trends in the analytical methods for water analysis; Tendencias de los metodos analiticos para el analisis del agua

    Energy Technology Data Exchange (ETDEWEB)

    Tortajada-Genero, L. A.; Campins-Falco, P. [Universidad de Valencia (Spain)

    2003-07-01

    The technological and methodological advances have provided and evolution of analytical chemistry, specially in the area of water analysis. There area wide variety of problems for this kind of analysis, as result of the high number of possible objectives. They involve from complex environmental studies to routine control of a physical-chemical parameter. Additionally, the variety of analysis to analyse is increasing as in total number as in complexity terms. The response has been the appearance of a high number of analytical methods. Some guidelines and recommendations have been described together with different strategies for quality assurance. In this paper, a review of the last analytical methods described in the scientific references for determinations in water was realised. The evolution and future perspectives were also studied. (Author) 16 refs.

  9. Report on DOE analytical laboratory capacity available to meet EM environmental sampling and analysis needs for FY 93-99

    International Nuclear Information System (INIS)

    1994-01-01

    The DOE Analytical Laboratory Capacity Study was conducted to give EM-263 current information about existing and future analytical capacities and capabilities of site laboratories within the DOE Complex. Each DOE site may have one or more analytical laboratories in operation. These facilities were established to support site missions such as production, research and development, and personnel and environmental monitoring. With changing site missions and the DOE directives for environmental monitoring and cleanup, these laboratories are either devoting or planning to devote resources to support EM activities. The DOE site laboratories represent a considerable amount of capital investment and analytical capability, capacity, and expertise that can be applied to support the EM mission. They not only provide cost-effective high-volume analytical laboratory services, but are also highly recognized analytical research and development centers. Several sites have already transferred their analytical capability from traditional production support to environmental monitoring and waste management support. A model was developed to determine the analytical capacity of all laboratories in the DOE Complex. The model was applied at nearly all the major laboratories and the results collected from these studies are summarized in this report

  10. Review of Analytes of Concern and Sample Methods for Closure of DOE High Level Waste Storage Tanks

    International Nuclear Information System (INIS)

    Thomas, T.R.

    2002-01-01

    Sampling residual waste after tank cleaning and analysis for analytes of concern to support closure and cleaning targets of large underground tanks used for storage of legacy high level radioactive waste (HLW) at Department of Energy (DOE) sites has been underway since about 1995. The DOE Tanks Focus Area (TFA) has been working with DOE tank sites to develop new sampling plans, and sampling methods for assessment of residual waste inventories. This paper discusses regulatory analytes of concern, sampling plans, and sampling methods that support closure and cleaning target activities for large storage tanks at the Hanford Site, the Savannah River Site (SRS), the Idaho National Engineering and Environmental Laboratory (INEEL), and the West Valley Demonstration Project (WVDP)

  11. NUMERICAL AND ANALYTIC METHODS OF ESTIMATION BRIDGES’ CONSTRUCTIONS

    Directory of Open Access Journals (Sweden)

    Y. Y. Luchko

    2010-03-01

    Full Text Available In this article the numerical and analytical methods of calculation of the stressed-and-strained state of bridge constructions are considered. The task on increasing of reliability and accuracy of the numerical method and its solution by means of calculations in two bases are formulated. The analytical solution of the differential equation of deformation of a ferro-concrete plate under the action of local loads is also obtained.

  12. Environmentally evaluated HPLC-ELSD method to monitor enzymatic synthesis of a non-ionic surfactant.

    Science.gov (United States)

    Gaber, Yasser; Akerman, Cecilia Orellana; Hatti-Kaul, Rajni

    2014-01-01

    N-Lauroyl-N-methylglucamide is a biodegradable surfactant derived from renewable resources. In an earlier study, we presented an enzymatic solvent-free method for synthesis of this compound. In the present report, the HPLC method developed to follow the reaction between lauric acid/methyl laurate and N-methyl glucamine (MEG) and its environmental assessment are described. Use of ultraviolet (UV) absorption or refractive index (RI) detectors did not allow the detection of N-methyl glucamine (MEG). With Evaporative light scattering detector ELSD, it was possible to apply a gradient elution, and detect MEG with a limit of detection, LOD = 0.12 μg. A good separation of the peaks: MEG, lauric acid, product (amide) and by-product (amide-ester) was achieved with the gradient program with a run time of 40 min. The setting of ELSD detector was optimized using methyl laurate as the analyte. LC-MS/MS was used to confirm the amide and amide-ester peaks. We evaluated the greenness of the developed method using the freely available software HPLC-Environmental Assessment Tool (HPLC-EAT) and the method got a scoring of 73 HPLC-EAT units, implying that the analytical procedure was more environmentally benign compared to some other methods reported in literature whose HPLC-EAT values scored up to 182. Use of ELSD detector allowed the detection and quantification of the substrates and the reaction products of enzymatic synthesis of the surfactant, N-lauroyl-N-methylglucamide. The developed HPLC method has acceptable environmental profile based on HPLC-EAT evaluation.

  13. Propulsion and launching analysis of variable-mass rockets by analytical methods

    OpenAIRE

    D.D. Ganji; M. Gorji; M. Hatami; A. Hasanpour; N. Khademzadeh

    2013-01-01

    In this study, applications of some analytical methods on nonlinear equation of the launching of a rocket with variable mass are investigated. Differential transformation method (DTM), homotopy perturbation method (HPM) and least square method (LSM) were applied and their results are compared with numerical solution. An excellent agreement with analytical methods and numerical ones is observed in the results and this reveals that analytical methods are effective and convenient. Also a paramet...

  14. A method for determining the analytical form of a radionuclide depth distribution using multiple gamma spectrometry measurements

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Steven Clifford, E-mail: sdewey001@gmail.com [United States Air Force School of Aerospace Medicine, Occupational Environmental Health Division, Health Physics Branch, Radiation Analysis Laboratories, 2350 Gillingham Drive, Brooks City-Base, TX 78235 (United States); Whetstone, Zachary David, E-mail: zacwhets@umich.edu [Radiological Health Engineering Laboratory, Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, 1906 Cooley Building, Ann Arbor, MI 48109-2104 (United States); Kearfott, Kimberlee Jane, E-mail: kearfott@umich.edu [Radiological Health Engineering Laboratory, Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, 1906 Cooley Building, Ann Arbor, MI 48109-2104 (United States)

    2011-06-15

    When characterizing environmental radioactivity, whether in the soil or within concrete building structures undergoing remediation or decommissioning, it is highly desirable to know the radionuclide depth distribution. This is typically modeled using continuous analytical expressions, whose forms are believed to best represent the true source distributions. In situ gamma ray spectroscopic measurements are combined with these models to fully describe the source. Currently, the choice of analytical expressions is based upon prior experimental core sampling results at similar locations, any known site history, or radionuclide transport models. This paper presents a method, employing multiple in situ measurements at a single site, for determining the analytical form that best represents the true depth distribution present. The measurements can be made using a variety of geometries, each of which has a different sensitivity variation with source spatial distribution. Using non-linear least squares numerical optimization methods, the results can be fit to a collection of analytical models and the parameters of each model determined. The analytical expression that results in the fit with the lowest residual is selected as the most accurate representation. A cursory examination is made of the effects of measurement errors on the method. - Highlights: > A new method for determining radionuclide distribution as a function of depth is presented. > Multiple measurements are used, with enough measurements to determine the unknowns in analytical functions that might describe the distribution. > The measurements must be as independent as possible, which is achieved through special collimation of the detector. > Although the effects of measurements errors may be significant on the results, an improvement over other methods is anticipated.

  15. Rigid inclusions-Comparison between analytical and numerical methods

    International Nuclear Information System (INIS)

    Gomez Perez, R.; Melentijevic, S.

    2014-01-01

    This paper compares different analytical methods for analysis of rigid inclusions with finite element modeling. First of all, the load transfer in the distribution layer is analyzed for its different thicknesses and different inclusion grids to define the range between results obtained by analytical and numerical methods. The interaction between the soft soil and the inclusion in the estimation of settlements is studied as well. Considering different stiffness of the soft soil, settlements obtained analytical and numerically are compared. The influence of the soft soil modulus of elasticity on the neutral point depth was also performed by finite elements. This depth has a great importance for the definition of the total length of rigid inclusion. (Author)

  16. Parameters estimation of the single and double diode photovoltaic models using a Gauss–Seidel algorithm and analytical method: A comparative study

    International Nuclear Information System (INIS)

    Et-torabi, K.; Nassar-eddine, I.; Obbadi, A.; Errami, Y.; Rmaily, R.; Sahnoun, S.; El fajri, A.; Agunaou, M.

    2017-01-01

    Highlights: • Comparative study of two methods: a Gauss Seidel method and an analytical method. • Five models are implemented to estimate the five parameters for single diode. • Two models are used to estimate the seven parameters for double diode. • The parameters are estimated under changing environmental conditions. • To choose method/model combination more adequate for each PV module technology. - Abstract: In the photovoltaic (PV) panels modeling field, this paper presents a comparative study of two parameter estimation methods: the iterative method called Gauss Seidel, applied on the single diode model, and the analytical method used on the double diode model. These parameter estimation methods are based on the manufacturer's datasheets. They are also tested on three PV modules of different technologies: multicrystalline (kyocera KC200GT), monocrystalline (Shell SQ80), and thin film (Shell ST40). For the iterative method, five existing mathematical models classified from 1 to 5 are used to estimate the parameters of these PV modules under varying environmental conditions. Only two models of them are used for the analytical method. Each model is based on the combination of the photocurrent and the reverse saturation current’s expressions in terms of temperature and irradiance. In addition, the results of the models’ simulation are compared with the experimental data obtained from the PV modules’ datasheets, in order to evaluate the accuracy of the models. The simulation shows that the I-V characteristics obtained are matching to the experimental data. In order to validate the reliability of the two methods, both the Absolute Error (AE) and the Root Mean Square Error (RMSE) were calculated. The results suggest that the analytical method can be very useful for monocrystalline and multicrystalline modules, but for the thin film module, the iterative method is the most suitable.

  17. Jet substructure with analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, Mrinal [University of Manchester, Consortium for Fundamental Physics, School of Physics and Astronomy, Manchester (United Kingdom); Fregoso, Alessandro; Powling, Alexander [University of Manchester, School of Physics and Astronomy, Manchester (United Kingdom); Marzani, Simone [Durham University, Institute for Particle Physics Phenomenology, Durham (United Kingdom)

    2013-11-15

    We consider the mass distribution of QCD jets after the application of jet-substructure methods, specifically the mass-drop tagger, pruning, trimming and their variants. In contrast to most current studies employing Monte Carlo methods, we carry out analytical calculations at the next-to-leading order level, which are sufficient to extract the dominant logarithmic behaviour for each technique, and compare our findings to exact fixed-order results. Our results should ultimately lead to a better understanding of these jet-substructure methods which in turn will influence the development of future substructure tools for LHC phenomenology. (orig.)

  18. Neutron activation analysis as analytical tool of environmental issue

    International Nuclear Information System (INIS)

    Otoshi, Tsunehiko

    2004-01-01

    Neutron activation analysis (NAA) ia applicable to the sample of wide range of research fields, such as material science, biology, geochemistry and so on. However, respecting the advantages of NAA, a sample with small amounts or a precious sample is the most suitable samples for NAA, because NAA is capable of trace analysis and non-destructive determination. In this paper, among these fields, NAA of atmospheric particulate matter (PM) sample is discussed emphasizing on the use of obtained data as an analytical tool of environmental issue. Concentration of PM in air is usually very low, and it is not easy to get vast amount of sample even using a high volume air sampling devise. Therefore, high sensitive NAA is suitable to determine elements in PM samples. Main components of PM is crust oriented silicate, and so on in rural/remote area, and carbonic materials and heavy metals are concentrated in PM in urban area, because of automobile exhaust and other anthropogenic emission source. Elemental pattern of PM reflects a condition of air around the monitoring site. Trends of air pollution can be traced by periodical monitoring of PM by NAA method. Elemental concentrations in air change by season. For example, crustal elements increase in dry season, and sea salts components increase their concentration when wind direction from sea is dominant. Elements that emitted from anthropogenic sources are mainly contained in fine portion of PM, and increase their concentration during winter season, when emission from heating system is high and air is stable. For further analysis and understanding of environmental issues, indicator elements for various emission sources, and elemental concentration ratios of some environmental samples and source portion assignment techniques are useful. (author)

  19. Analytical N beam position monitor method

    Directory of Open Access Journals (Sweden)

    A. Wegscheider

    2017-11-01

    Full Text Available Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β^{*}-leveling on luminosity will require many operational optics. A fast measurement of the β-function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs. A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  20. Analytical N beam position monitor method

    Science.gov (United States)

    Wegscheider, A.; Langner, A.; Tomás, R.; Franchi, A.

    2017-11-01

    Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β*-leveling on luminosity will require many operational optics. A fast measurement of the β -function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs). A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  1. Systems and Methods for Composable Analytics

    Science.gov (United States)

    2014-04-29

    simplistic module that performs a mathematical operation on two numbers. The most important method is the Execute() method. This will get called when it is...addition, an input control is also specified in the example below. In this example, the mathematical operator can only be chosen from a preconfigured...approaches. Some of the industries that could benefit from Composable Analytics include pharmaceuticals, health care, insurance, actuaries , and

  2. Hanford environmental analytical methods (methods as of March 1990)

    International Nuclear Information System (INIS)

    Goheen, S.D.; McCulloch, M.; Daniel, J.L.

    1993-05-01

    Information is provided on the techniques employed towards the chemical analysis of volatile, semi-volatile matter, pesticides and PCB's at the Hanford Reservation. Sample preparation methods are included

  3. 7 CFR 93.13 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... No. 1, USDA, Agricultural Marketing Service, Science and Technology, 3521 South Agriculture Building... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 93.13 Section 93.13 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards...

  4. Secondary waste minimization in analytical methods

    International Nuclear Information System (INIS)

    Green, D.W.; Smith, L.L.; Crain, J.S.; Boparai, A.S.; Kiely, J.T.; Yaeger, J.S.; Schilling, J.B.

    1995-01-01

    The characterization phase of site remediation is an important and costly part of the process. Because toxic solvents and other hazardous materials are used in common analytical methods, characterization is also a source of new waste, including mixed waste. Alternative analytical methods can reduce the volume or form of hazardous waste produced either in the sample preparation step or in the measurement step. The authors are examining alternative methods in the areas of inorganic, radiological, and organic analysis. For determining inorganic constituents, alternative methods were studied for sample introduction into inductively coupled plasma spectrometers. Figures of merit for the alternative methods, as well as their associated waste volumes, were compared with the conventional approaches. In the radiological area, the authors are comparing conventional methods for gross α/β measurements of soil samples to an alternative method that uses high-pressure microwave dissolution. For determination of organic constituents, microwave-assisted extraction was studied for RCRA regulated semivolatile organics in a variety of solid matrices, including spiked samples in blank soil; polynuclear aromatic hydrocarbons in soils, sludges, and sediments; and semivolatile organics in soil. Extraction efficiencies were determined under varying conditions of time, temperature, microwave power, moisture content, and extraction solvent. Solvent usage was cut from the 300 mL used in conventional extraction methods to about 30 mL. Extraction results varied from one matrix to another. In most cases, the microwave-assisted extraction technique was as efficient as the more common Soxhlet or sonication extraction techniques

  5. Recovery of environmental analytes from clays and soils by supercritical fluid extracting/gas chromatography

    International Nuclear Information System (INIS)

    Emery, A.P.; Chesler, S.N.; MacCrehan, W.A.

    1992-01-01

    This paper reports on Supercritical Fluid Extraction (SFE) which promises to provide rapid extractions of organic analytes from environmental sample types without the use of hazardous solvents. In addition, SFE protocols using commercial instrumentation can be automated lowering analysis costs. Because of these benefits, we are investigating SFE as an alternative to the solvent extraction (eg. Soxhlet and sonication) techniques required in many EPA test procedures. SFE, using non-polar carbon dioxide as well as more polar supercritical fluids, was used to determine n-alkane hydrocarbons and polynuclear aromatic hydrocarbons (PAHs) in solid samples. The extraction behavior of these analyte classes from environmentally-contaminated soil matrices and model soil and clay matrices was investigated using a SFE apparatus in which the extracted analytes were collected on a solid phase trap and then selectively eluted with a solvent. The SFE conditions for quantitative recovery of n-alkane hydrocarbons in diesel fuel from a series of clays and soils were determined using materials prepared at the 0.02% level with diesel fuel oil in order to simplify analyte collection and analysis after extraction. The effect of extraction parameters including temperature, fluid flow rate and modifier addition were investigated by monitoring the amount of diesel fuel extracted as a function of time

  6. Analytical method for solving radioactive transformations

    International Nuclear Information System (INIS)

    Vudakin, Z.

    1999-01-01

    Analytical method for solving radioactive transformations is presented in this paper. High accuracy series expansion of the depletion function and nonsingular Bateman coefficients are used to overcome numerical difficulties when applying well-known Bateman solution of a simple radioactive decay. Generality and simplicity of the method are found to be useful in evaluating nuclide chains with one hundred or more nuclides in the chain. Method enables evaluation of complete chain, without elimination of short-lives nuclides. It is efficient and accurate

  7. A New Method to Study Analytic Inequalities

    Directory of Open Access Journals (Sweden)

    Xiao-Ming Zhang

    2010-01-01

    Full Text Available We present a new method to study analytic inequalities involving n variables. Regarding its applications, we proved some well-known inequalities and improved Carleman's inequality.

  8. Application of advanced nuclear and instrumental analytical techniques for characterisation of environmental materials

    International Nuclear Information System (INIS)

    Sudersanan, M.; Pawaskar, P.B.; Kayasth, S.R.; Kumar, S.C.

    2002-01-01

    Full text: Increasing realisation about the toxic effects of metal ions in environmental materials has given an impetus to research on analytical techniques for their characterization. The large number of analytes present at very low levels has necessitated the use of sensitive, selective and element specific techniques for their characterization. The concern about precision and accuracy on such analysis, which have socio-economic bearing, has emphasized the use of Certified Reference Materials and the use of multi-technique approach for the unambiguous characterization of analytes. The recent work carried out at Analytical Chemistry Division, BARC on these aspects is presented in this paper. Increasing use of fossil fuels has led to the generation of large quantities of fly ash which pose problems of safe disposal. The utilization of these materials for land filling is an attractive option but the presence of trace amounts of toxic metals like mercury, arsenic, lead etc may cause environmental problems. In view of the inhomogeneous nature of the material, efficient sample processing is an important factor, in addition to the validation of the results by the use of proper standards. Analysis was carried out on flyash samples received as reference materials and also as samples from commercial sources using a combination of both nuclear techniques like INAA and RNAA as well as other techniques like AAS, ICPAES, cold vapour AAS for mercury and hydride generation technique for arsenic. Similar analysis using nuclear techniques was employed for the characterization of air particulates. Biological materials often serve as sensitive indicator materials for pollution measurements. They are also employed for studies on the uptake of toxic metals like U, Th, Cd, Pb, Hg etc. The presence of large amounts of organic materials in them necessitate an appropriate sample dissolution procedure. In view of the possibility of loss of certain analytes like Cd, Hg, As, by high

  9. Evaluation of environmental impact by LCA method. LCA shuho ni yoru kankyo fuka hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Sakamura, H.; Utsuno, F.; Yasui, I. (The University of Tokyo, Tokyo (Japan). Institute of Industrial Science)

    1994-06-01

    This paper explains the concept, history, and analytic methods of life cycle assessment (LCA), showing its application to beer bottles and cement factories as specific examples. The LCA is a method to calculate substances and energies put into the whole process of production of a product from raw material mining to product wasting and environmental loads emitted therefrom. It also evaluates the result collectively and quantitatively. A first case of the research is reportedly the one performed at Coca-Cola Co., Ltd. in 1969. Full-scale researches have gone forward in European countries in the recent several years, and are progressing to international networks. The analytic methods can be divided largely into an accumulation method to analyze data in each process and add them up, and a method to use an industrial association table. The former method is the most generally used method currently in overseas countries if referred to the LCA. Because the LCA can cause the analytic result and evaluation to vary depending on the purpose, it is important to define the goal, and set the scope. The LCA must develop in the future although it has a number of problems. 10 refs., 5 figs., 2 tabs.

  10. The complementary use of radioanalytical methods and trace analysis methods for the characterisation of environmental IAEA reference materials

    International Nuclear Information System (INIS)

    De Regge, P.; Burns, K.; Campbell, M.; Makarewicz, M.; Markowicz, A.; Mattiuzzi, M.; Tajani, A.; Toervenyi, A.; Zeiller, E.

    2001-01-01

    The IAEA laboratories have access to both nuclear analytical methods and conventional instrumental methods for trace analysis for the characterisation of its environmental and biological reference materials. A technical concept integrating the homogeneity data, the recommended test portion mass and the uncertainty on the trace element concentrations is explored using a combination of INAA, XRF, ICP-MS, ICP-AES, and AAS. The above approach is illustrated by selected examples of reference materials currently under evaluation for their trace element content. They include some or all of the following elements Al, As, Br, Ca, Cd, Co, Cr, Cs, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, Ni, Pb, Rb, Se, Sr, Th, U, Zn in environmental biomonitor organisms (lichen, algae) and air dust filters. (author)

  11. Ensuring comparability of data generated by multiple analytical laboratories for environmental decision making at the Fernald Environmental Management Project

    International Nuclear Information System (INIS)

    Sutton, C.; Campbell, B.A.; Danahy, R.J.; Dugan, T.A.; Tomlinson, F.K.

    1994-01-01

    The Fernald Environmental Management Project is a US Department of Energy (DOE)-owned facility located 17 miles northwest of Cincinnati, Ohio. From 1952 until 1989, the Fernald site provided high-purity uranium metal products to support US defense programs. In 1989 the mission of Fernald changed from one of uranium production to one of environmental restoration. At Fernald, multiple functional programs require analytical data. Inorganic and organic data for these programs are currently generated by seven laboratories, while radiochemical data are being obtained from six laboratories. Quality Assurance (QA) and Quality Control (QC) programs have been established to help ensure comparability of data generated by multiple laboratories at different times. The quality assurance program for organic and inorganic measurements specifies which analytical methodologies and sample preparation procedures are to be used based on analyte class, sample matrix, and data quality requirements. In contrast, performance specifications have been established for radiochemical analyses. A blind performance evaluation program for all laboratories, both on-site and subcontracted commercial laboratories, provides continuous feedback on data quality. The necessity for subcontractor laboratories to participate in the performance evaluation program is a contractual requirement. Similarly, subcontract laboratories are contractually required to generate data which meet radiochemical performance specifications. The Fernald on-site laboratory must also fulfill these requirements

  12. Appendices to report on DOE analytical laboratory capacity available to meet EM environmental sampling and analysis needs for FY 93-99

    International Nuclear Information System (INIS)

    1994-01-01

    The DOE Analytical Laboratory Capacity Study was conducted to give EM-263 current information about existing and future analytical capacities and capabilities of site laboratories within the DOE Complex. Each DOE site may have one or more analytical laboratories in operation. These facilities were established to support site missions such as production, research and development, and personnel and environmental monitoring. With changing site missions and the DOE directives for environmental monitoring and cleanup, these laboratories are either devoting or planning to devote resources to support EM activities. The DOE site laboratories represent a considerable amount of capital investment and analytical capability, capacity, and expertise that can be applied to support the EM mission. They not only provide cost-effective high-volume analytical laboratory services, but are also highly recognized analytical research and development centers. Several sites have already transferred their analytical capability from traditional production support to environmental monitoring and waste management support. A model was developed to determine the analytical capacity of all laboratories in the DOE Complex. The model was applied at nearly all the major laboratories and the results collected from these studies are summarized in this report

  13. Decision analytic methods in RODOS

    International Nuclear Information System (INIS)

    Borzenko, V.; French, S.

    1996-01-01

    In the event of a nuclear accident, RODOS seeks to provide decision support at all levels ranging from the largely descriptive to providing a detailed evaluation of the benefits and disadvantages of various countermeasure strategies and ranking them according to the societal preferences as perceived by the decision makers. To achieve this, it must draw upon several decision analytic methods and bring them together in a coherent manner so that the guidance offered to decision makers is consistent from one stage of an accident to the next. The methods used draw upon multi-attribute value and utility theories

  14. Development of rapid analytical methods for Sr-89/90, Pu-239/40 and Pu-238 activity concentrations in fallout, surface water, plants and aerosol filters based on modified routine used analytical procedures

    International Nuclear Information System (INIS)

    Siebert, H.-U.; Thiele, J.; Loennig, M.; Kunert, M.; Kranl, H.

    1995-01-01

    In accordance with the tasks of the National Board for Atomic Safety and Radiation Protection in the system of nuclear, environmental surveillance for many years there has existed a traditional spectrum of methods for the determination of radionuclides in environmental media. Due to the existing environmental monitoring programmes: surveillance of GDR territory with respect to the impact of global radioactive fallout; surveillance of the environment of nuclear facilities and nuclear power plants; surveillance of the environment of mining facilities, and the involved necessity of analyzing a great number of samples, the following demands were made on the radionuclide determination methods: as few as possible, simple and safe steps of analysis; use of effective nuclide selective activity measuring methods; parallel processing of several samples; possible determination of several individual nuclides by one analytic approach; selective separation methods to produce pure element-specific measuring samples, due to the necessary use of gross activity measurements; using of same principal schemes of analysis for different sample media excluding methods of decomposition

  15. Development of precise analytical methods for strontium and lanthanide isotopic ratios using multiple collector inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Ohno, Takeshi; Takaku, Yuichi; Hisamatsu, Shun'ichi

    2007-01-01

    We have developed precise analytical methods for strontium and lanthanide isotopic ratios using multiple collector-ICP-mass spectrometry (MC-ICP-MS) for experimental and environmental studies of their behavior. In order to obtain precise isotopic data using MC-ICP-MS, the mass discrimination effect was corrected by an exponential law correction method. The resulting isotopic data demonstrated that highly precise isotopic analyses (better than 0.1 per mille as 2SD) could be achieved. We also adopted a de-solvating nebulizer system to improve the sensitivity. This system could minimize the water load into the plasma and provided about five times larger intensity of analyte than a conventional nebulizer system did. (author)

  16. Current status of JAERI program on development of ultra-trace-analytical technology for safeguards environmental samples

    International Nuclear Information System (INIS)

    Adachi, T.; Usuda, S.; Watanabe, K.

    2001-01-01

    Full text: In order to contribute to the strengthened safeguards system based on the Program 93+2 of the IAEA, Japan Atomic Energy Research Institute (JAERI) is developing analytical technology for ultra-trace amounts of nuclear materials in environmental samples, and constructed the CLEAR facility (Clean Laboratory for Environmental Analysis and Research) for this purpose. The development of the technology is carried out, at existing laboratories for time being, in the following fields: screening, bulk analysis and particle analysis. The screening aims at estimating the amounts of nuclear materials in environmental samples to be introduced into the clean rooms, and is the first step to avoid cross-contamination among the samples and contamination of the clean rooms themselves. In addition to ordinary radiation spectrometry, Compton suppression technique was applied to low energy γ- and X-ray measurements, and sufficient reduction in background level has been demonstrated. Another technique in examination is imaging-plate method, which is a kind of autoradiography and suitable for determination of radioactive-particle distribution in the samples as well as for semiquantitative determination. As for the bulk analysis, the efforts are temporally made on uranium in swipe samples. Preliminary examination for optimization of sample pre-treatment conditions is in progress. At present, ashing by low-temperature-plasma method gives better results than high-temperature ashing or acid leaching. For the isotopic ratio measurement, instrumental performance of inductively-coupled plasma mass spectrometry (ICP-MS) are mainly examined because sample preparation for ICP-MS is simpler than that for thermal ionization mass spectrometry (TIMS). It was found by our measurement that the swipe material (TexWipe TX304, usually used by IAEA) contains un-negligible uranium blank with large deviation (2-6 ng/sheet). This would introduce significant uncertainty in the trace analysis. JAERI

  17. A rapid and sensitive analytical method for the determination of 14 pyrethroids in water samples.

    Science.gov (United States)

    Feo, M L; Eljarrat, E; Barceló, D

    2010-04-09

    A simple, efficient and environmentally friendly analytical methodology is proposed for extracting and preconcentrating pyrethroids from water samples prior to gas chromatography-negative ion chemical ionization mass spectrometry (GC-NCI-MS) analysis. Fourteen pyrethroids were selected for this work: bifenthrin, cyfluthrin, lambda-cyhalothrin, cypermethrin, deltamethrin, esfenvalerate, fenvalerate, fenpropathrin, tau-fluvalinate, permethrin, phenothrin, resmethrin, tetramethrin and tralomethrin. The method is based on ultrasound-assisted emulsification-extraction (UAEE) of a water-immiscible solvent in an aqueous medium. Chloroform was used as extraction solvent in the UAEE technique. Target analytes were quantitatively extracted achieving an enrichment factor of 200 when 20 mL aliquot of pure water spiked with pyrethroid standards was extracted. The method was also evaluated with tap water and river water samples. Method detection limits (MDLs) ranged from 0.03 to 35.8 ng L(-1) with RSDs values or =0.998. Recovery values were in the range of 45-106%, showing satisfactory robustness of the method for analyzing pyrethroids in water samples. The proposed methodology was applied for the analysis of river water samples. Cypermethrin was detected at concentration levels ranging from 4.94 to 30.5 ng L(-1). Copyright 2010 Elsevier B.V. All rights reserved.

  18. An overview of the environmental applicability of vermicompost: from wastewater treatment to the development of sensitive analytical methods.

    Science.gov (United States)

    Pereira, Madson de Godoi; Neta, Lourdes Cardoso de Souza; Fontes, Maurício Paulo Ferreira; Souza, Adriana Nascimento; Matos, Thaionara Carvalho; Sachdev, Raquel de Lima; dos Santos, Arnaud Victor; da Guarda Souza, Marluce Oliveira; de Andrade, Marta Valéria Almeida Santana; Paulo, Gabriela Marinho Maciel; Ribeiro, Joselito Nardy; Ribeiro, Araceli Verónica Flores Nardy

    2014-01-01

    The use of vermicompost (humified material) for treating wastewaters, remediating polluted soils, improving agricultural productivity, protecting crop production, and developing sensitive analytical methods is reviewed here, covering the past 17 years. The main advantages of vermicompost, considering all applications covered in this paper, comprise (i) easy acquisition, (ii) low costs, (iii) structural, chemical, and biological characteristics responsible for exceptional adsorptive capacities as well as pollutant degradation, and (iv) the promotion of biocontrol. Specifically, for wastewater decontamination, a considerable number of works have verified the adsorption of toxic metals, but the application of vermicompost is still scarce for the retention of organic compounds. Problems related to the final disposal of enriched vermicompost (after treatment steps) are often found, in spite of some successful destinations such as organic fertilizer. For decontaminating soils, the use of vermicompost is quite scarce, mainly for inorganic pollutants. In agricultural productivity and biocontrol, vermicompost imparts remarkable benefits regarding soil aggregation, plant nutrition, and the development of beneficial microorganisms against phytopathogens. Finally, the use of vermicompost in sensitive analytical methods for quantifying toxic metals is the newest application of this adsorbent.

  19. Functional analytic multisensory environmental therapy for people with dementia.

    Science.gov (United States)

    Staal, Jason A

    2012-01-01

    This paper introduces Functional Analytic Multisensory Environmental Therapy (FAMSET) for use with elders with dementia while using a multisensory environment/snoezelen room. The model introduces behavioral theory and practice to the multisensory environment treatment, addressing assessment, and, within session techniques, integrating behavioral interventions with emotion-oriented care. A modular approach is emphasized to delineate different treatment phases for multisensory environment therapy. The aim of the treatment is to provide a safe and effective framework for reducing the behavioral disturbance of the disease process, increasing elder well-being, and to promote transfer of positive effects to other environments outside of the multisensory treatment room.

  20. Atomic and nuclear analytical methods. XRF, Moessbauer, XPS, NAA and ion-beam spectroscopic techniques

    International Nuclear Information System (INIS)

    Verma, H.R.

    2007-01-01

    This book is a blend of analytical methods based on the phenomenon of atomic and nuclear physics. It comprises comprehensive presentations about X-ray Fluorescence (XRF), Moessbauer Spectroscopy (MS), X-ray Photoelectron Spectroscopy (XPS), Neutron- Activation Analysis (NAA), Particle Induced X-ray Emission Analysis (PIXE), Rutherford Backscattering Analysis (RBS), Elastic Recoil Detection (ERD), Nuclear Reaction Analysis (NRA), Particle Induced Gamma-ray Emission Analysis (PIGE), and Accelerator Mass Spectrometry (AMS). These techniques are commonly applied in the fields of medicine, biology, environmental studies, archaeology or geology et al. and pursued in major international research laboratories. (orig.)

  1. Indoor air - assessment: Methods of analysis for environmental carcinogens

    International Nuclear Information System (INIS)

    Peterson, M.R.; Naugle, D.F.; Berry, M.A.

    1990-06-01

    The monograph describes, in a general way, published sampling procedures and analytical approaches for known and suspected carcinogens. The primary focus is upon carcinogens found in indoor air, although the methods described are applicable to other media or environments. In cases where there are no published methods for a particular pollutant in indoor air, methods developed for the workplace and for ambient air are included since they should be adaptable to indoor air. Known and suspected carcinogens have been grouped into six categories for the purposes of this and related work. The categories are radon, asbestos, organic compounds, inorganic species, particles, and non-ionizing radiation. Some methods of assessing exposure that are not specific to any particular pollutant category are covered in a separate section. The report is the fifth in a series of EPA/Environmental Criteria and Assessment Office Monographs

  2. Development of an analytical procedure for plutonium in the concentration range of femtogram/gram and its application to environmental samples

    International Nuclear Information System (INIS)

    Schuettelkopf, H.

    1981-09-01

    To study the behaviour of plutonium in the environment and to measure plutonium in the vicinity of nuclear facilities, a quick, sensitive analytical method is required which can be applied to all sample materials found in the environment. For a sediment contaminated with plutonium a boiling out method using first HNO 3 /HF and subsequently HNO 3 /Al(NO 3 ) 3 was found to be successful. The leaching solution was then extracted by TOPO and the plutonium backextracted by ascorbic acid/HCl. Some different purification steps and finally electroplating using ammonium oxalate led to an optimum sample for α- spectroscopic determination of plutonium. An analytical method was worked out for plutonium which can be applied to all materials found in the environment. The sample size is 100 g but it might also be much greater. The average chemical yield is 70 and 80%. The detection limit for soil samples is 0.1 fCi/g and for plant samples 0.5 fCi/g. One technician can perform eight analyses per working day. The analytical procedure was applied to a large number of environmental samples and the results of these analyses are indicated. (orig./RB) [de

  3. Teaching Analytical Method Transfer through Developing and Validating Then Transferring Dissolution Testing Methods for Pharmaceuticals

    Science.gov (United States)

    Kimaru, Irene; Koether, Marina; Chichester, Kimberly; Eaton, Lafayette

    2017-01-01

    Analytical method transfer (AMT) and dissolution testing are important topics required in industry that should be taught in analytical chemistry courses. Undergraduate students in senior level analytical chemistry laboratory courses at Kennesaw State University (KSU) and St. John Fisher College (SJFC) participated in development, validation, and…

  4. Recent developments in analytical detection methods for radiation processed foods

    International Nuclear Information System (INIS)

    Wu Jilan

    1993-01-01

    A short summary of the programmes of 'ADMIT' (FAO/IAEA) and the developments in analytical detection methods for radiation processed foods has been given. It is suggested that for promoting the commercialization of radiation processed foods and controlling its quality, one must pay more attention to the study of analytical detection methods of irradiated food

  5. Method validation and uncertainty evaluation of organically bound tritium analysis in environmental sample.

    Science.gov (United States)

    Huang, Yan-Jun; Zeng, Fan; Zhang, Bing; Chen, Chao-Feng; Qin, Hong-Juan; Wu, Lian-Sheng; Guo, Gui-Yin; Yang, Li-Tao; Shang-Guan, Zhi-Hong

    2014-08-01

    The analytical method for organically bound tritium (OBT) was developed in our laboratory. The optimized operating conditions and parameters were established for sample drying, special combustion, distillation, and measurement on a liquid scintillation spectrometer (LSC). Selected types of OBT samples such as rice, corn, rapeseed, fresh lettuce and pork were analyzed for method validation of recovery rate reproducibility, the minimum detection concentration, and the uncertainty for typical low level environmental sample was evaluated. The combustion water recovery rate of different dried environmental sample was kept at about 80%, the minimum detection concentration of OBT ranged from 0.61 to 0.89 Bq/kg (dry weight), depending on the hydrogen content. It showed that this method is suitable for OBT analysis of environmental sample with stable recovery rate, and the combustion water yield of a sample with weight about 40 g would provide sufficient quantity for measurement on LSC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Description of JNC's analytical method and its performance for FBR cores

    International Nuclear Information System (INIS)

    Ishikawa, M.

    2000-01-01

    The description of JNC's analytical method and its performance for FBR cores includes: an outline of JNC's Analytical System Compared with ERANOS; a standard data base for FBR Nuclear Design in JNC; JUPITER Critical Experiment; details of Analytical Method and Its Effects on JUPITER; performance of JNC Analytical System (effective multiplication factor k eff , control rod worth, and sodium void reactivity); design accuracy of a 600 MWe-class FBR Core. JNC developed a consistent analytical system for FBR core evaluation, based on JENDL library, f-table method, and three dimensional diffusion/transport theory, which includes comprehensive sensitivity tools to improve the prediction accuracy of core parameters. JNC system was verified by analysis of JUPITER critical experiment, and other facilities. Its performance can be judged quite satisfactory for FBR-core design work, though there is room for further improvement, such as more detailed treatment of cross-section resonance regions

  7. Extension of the analytic nodal method to four energy groups

    International Nuclear Information System (INIS)

    Parsons, D.K.; Nigg, D.W.

    1985-01-01

    The Analytic Nodal Method is one of several recently-developed coarse mesh numerical methods for efficiently and accurately solving the multidimensional static and transient neutron diffusion equations. This summary describes a mathematically rigorous extension of the Analytic Nodal Method to the frequently more physically realistic four-group case. A few general theoretical considerations are discussed, followed by some calculated results for a typical steady-state two-dimensional PWR quarter core application. 8 refs

  8. Vertical equilibrium with sub-scale analytical methods for geological CO2 sequestration

    KAUST Repository

    Gasda, S. E.; Nordbotten, J. M.; Celia, M. A.

    2009-01-01

    equilibrium with sub-scale analytical method (VESA) combines the flexibility of a numerical method, allowing for heterogeneous and geologically complex systems, with the efficiency and accuracy of an analytical method, thereby eliminating expensive grid

  9. Application of an analytical method for solution of thermal hydraulic conservation equations

    Energy Technology Data Exchange (ETDEWEB)

    Fakory, M.R. [Simulation, Systems & Services Technologies Company (S3 Technologies), Columbia, MD (United States)

    1995-09-01

    An analytical method has been developed and applied for solution of two-phase flow conservation equations. The test results for application of the model for simulation of BWR transients are presented and compared with the results obtained from application of the explicit method for integration of conservation equations. The test results show that with application of the analytical method for integration of conservation equations, the Courant limitation associated with explicit Euler method of integration was eliminated. The results obtained from application of the analytical method (with large time steps) agreed well with the results obtained from application of explicit method of integration (with time steps smaller than the size imposed by Courant limitation). The results demonstrate that application of the analytical approach significantly improves the numerical stability and computational efficiency.

  10. An Overview of the Environmental Applicability of Vermicompost: From Wastewater Treatment to the Development of Sensitive Analytical Methods

    OpenAIRE

    Pereira, Madson de Godoi; Cardoso de Souza Neta, Lourdes; Fontes, Maurício Paulo Ferreira; Souza, Adriana Nascimento; Carvalho Matos, Thaionara; de Lima Sachdev, Raquel; dos Santos, Arnaud Victor; Oliveira da Guarda Souza, Marluce; de Andrade, Marta Valéria Almeida Santana; Marinho Maciel Paulo, Gabriela; Ribeiro, Joselito Nardy; Verónica Flores Nardy Ribeiro, Araceli

    2014-01-01

    The use of vermicompost (humified material) for treating wastewaters, remediating polluted soils, improving agricultural productivity, protecting crop production, and developing sensitive analytical methods is reviewed here, covering the past 17 years. The main advantages of vermicompost, considering all applications covered in this paper, comprise (i) easy acquisition, (ii) low costs, (iii) structural, chemical, and biological characteristics responsible for exceptional adsorptive capacities...

  11. Development and Validation of Analytical Method for Losartan ...

    African Journals Online (AJOL)

    Development and Validation of Analytical Method for Losartan-Copper Complex Using UV-Vis Spectrophotometry. ... Tropical Journal of Pharmaceutical Research ... Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with ...

  12. Analytical strategic environmental assessment (ANSEA) developing a new approach to SEA

    International Nuclear Information System (INIS)

    Dalkmann, Holger; Herrera, Rodrigo Jiliberto; Bongardt, Daniel

    2004-01-01

    The objective of analytical strategic environmental assessment (ANSEA) is to provide a decision-centred approach to the SEA process. The ANSEA project evolved from the realisation that, in many cases, SEA, as currently practised, is not able to ensure an appropriate integration of environmental values. The focus of SEA is on predicting impacts, but the tool takes no account of the decision-making processes it is trying to influence. At strategic decision-making levels, in turn, it is often difficult to predict impacts with the necessary exactitude. The decision-making sciences could teach some valuable lessons here. Instead of focusing on the quantitative prediction of environmental consequences, the ANSEA approach concentrates on the integration of environmental objectives into decision-making processes. Thus, the ANSEA approach provides a framework for analysing and assessing the decision-making processes of policies, plans and programmes (PPP). To enhance environmental integration into the decision-making process, decision windows (DW) can be identified. The approach is designed to be objective and transparent to ensure that environmental considerations are taken into account, or--from an ex-post perspective--to allow an evaluation of how far environmental considerations have been integrated into the decision-making process under assessment. The paper describes the concepts and the framework of the ANSEA approach and discusses its relation to SEA and the EC Directive

  13. Analytical techniques and method validation for the measurement of selected semivolatile and nonvolatile organofluorochemicals in air.

    Science.gov (United States)

    Reagen, William K; Lindstrom, Kent R; Thompson, Kathy L; Flaherty, John M

    2004-09-01

    The widespread use of semi- and nonvolatile organofluorochemicals in industrial facilities, concern about their persistence, and relatively recent advancements in liquid chromatography/mass spectrometry (LC/MS) technology have led to the development of new analytical methods to assess potential worker exposure to airborne organofluorochemicals. Techniques were evaluated for the determination of 19 organofluorochemicals and for total fluorine in ambient air samples. Due to the potential biphasic nature of most of these fluorochemicals when airborne, Occupational Safety and Health Administration (OSHA) versatile sampler (OVS) tubes were used to simultaneously trap fluorochemical particulates and vapors from workplace air. Analytical methods were developed for OVS air samples to quantitatively analyze for total fluorine using oxygen bomb combustion/ion selective electrode and for 17 organofluorochemicals using LC/MS and gas chromatography/mass spectrometry (GC/MS). The experimental design for this validation was based on the National Institute of Occupational Safety and Health (NIOSH) Guidelines for Air Sampling and Analytical Method Development and Evaluation, with some revisions of the experimental design. The study design incorporated experiments to determine analytical recovery and stability, sampler capacity, the effect of some environmental parameters on recoveries, storage stability, limits of detection, precision, and accuracy. Fluorochemical mixtures were spiked onto each OVS tube over a range of 0.06-6 microg for each of 12 compounds analyzed by LC/MS and 0.3-30 microg for 5 compounds analyzed by GC/MS. These ranges allowed reliable quantitation at 0.001-0.1 mg/m3 in general for LC/MS analytes and 0.005-0.5 mg/m3 for GC/MS analytes when 60 L of air are sampled. The organofluorochemical exposure guideline (EG) is currently 0.1 mg/m3 for many analytes, with one exception being ammonium perfluorooctanoate (EG is 0.01 mg/m3). Total fluorine results may be used

  14. Mathematical methods for physical and analytical chemistry

    CERN Document Server

    Goodson, David Z

    2011-01-01

    Mathematical Methods for Physical and Analytical Chemistry presents mathematical and statistical methods to students of chemistry at the intermediate, post-calculus level. The content includes a review of general calculus; a review of numerical techniques often omitted from calculus courses, such as cubic splines and Newton's method; a detailed treatment of statistical methods for experimental data analysis; complex numbers; extrapolation; linear algebra; and differential equations. With numerous example problems and helpful anecdotes, this text gives chemistry students the mathematical

  15. Analytical Methods for Biomass Characterization during Pretreatment and Bioconversion

    Energy Technology Data Exchange (ETDEWEB)

    Pu, Yunqiao [ORNL; Meng, Xianzhi [University of Tennessee, Knoxville (UTK); Yoo, Chang Geun; Li, Mi; Ragauskas, Arthur J [ORNL

    2016-01-01

    Lignocellulosic biomass has been introduced as a promising resource for alternative fuels and chemicals because of its abundance and complement for petroleum resources. Biomass is a complex biopolymer and its compositional and structural characteristics largely vary depending on its species as well as growth environments. Because of complexity and variety of biomass, understanding its physicochemical characteristics is a key for effective biomass utilization. Characterization of biomass does not only provide critical information of biomass during pretreatment and bioconversion, but also give valuable insights on how to utilize the biomass. For better understanding biomass characteristics, good grasp and proper selection of analytical methods are necessary. This chapter introduces existing analytical approaches that are widely employed for biomass characterization during biomass pretreatment and conversion process. Diverse analytical methods using Fourier transform infrared (FTIR) spectroscopy, gel permeation chromatography (GPC), and nuclear magnetic resonance (NMR) spectroscopy for biomass characterization are reviewed. In addition, biomass accessibility methods by analyzing surface properties of biomass are also summarized in this chapter.

  16. Performance evaluation of the food and environmental monitoring radio-analytical laboratory in Ghana

    International Nuclear Information System (INIS)

    Agyeman, Lilian Ataa

    2016-06-01

    Since the establishment of the Radiation Protection Institute’s Food and Environmental Laboratory in 1988, there has never been any thorough evaluation of the activities of the facility to provide assurance of the quality of analytical results produced by the laboratory. The objective of this study, therefore, was to assess the performance level of the Food and Environmental monitoring laboratory with respect to the requirements for a standard analytical laboratory (IAEA, 1989) and ISO 17025. The study focused on the performance of the Gamma Spectrometry laboratory of the Radiation Protection Institute, Ghana Atomic Energy Commission which has been involved in monitoring of radionuclides in food and environmental samples. In doing that, data from 1988 to 2015 was reviewed to ascertain whether the Laboratory has being performing as required in providing quality results on food and environmental samples measured. Besides this data (records kept), the evaluation also covered some Technical Quality Control measures, such as Energy and Efficiency Calibration, that need to be put in place for such laboratories. The laboratory meets almost all conditions and equipment requirements of IAEA (1989), however the laboratory falls short of the management requirements of ISO 17025. Based on the results it was recommended, among others, that management of the laboratory should ensure there are procedures for how calibration and testing is performed for different types of equipment and also the competence of all who operate specific equipment, perform tests, evaluate results and sign test reports ensured. (au)

  17. Functional Analytic Multisensory Environmental Therapy for People with Dementia

    Directory of Open Access Journals (Sweden)

    Jason A. Staal

    2012-01-01

    Full Text Available This paper introduces Functional Analytic Multisensory Environmental Therapy (FAMSET for use with elders with dementia while using a multisensory environment/snoezelen room. The model introduces behavioral theory and practice to the multisensory environment treatment, addressing assessment, and, within session techniques, integrating behavioral interventions with emotion-oriented care. A modular approach is emphasized to delineate different treatment phases for multisensory environment therapy. The aim of the treatment is to provide a safe and effective framework for reducing the behavioral disturbance of the disease process, increasing elder well-being, and to promote transfer of positive effects to other environments outside of the multisensory treatment room.

  18. An Overview of the Environmental Applicability of Vermicompost: From Wastewater Treatment to the Development of Sensitive Analytical Methods

    Science.gov (United States)

    Pereira, Madson de Godoi; Cardoso de Souza Neta, Lourdes; Fontes, Maurício Paulo Ferreira; Souza, Adriana Nascimento; Carvalho Matos, Thaionara; de Lima Sachdev, Raquel; dos Santos, Arnaud Victor; Oliveira da Guarda Souza, Marluce; de Andrade, Marta Valéria Almeida Santana; Marinho Maciel Paulo, Gabriela; Ribeiro, Joselito Nardy; Verónica Flores Nardy Ribeiro, Araceli

    2014-01-01

    The use of vermicompost (humified material) for treating wastewaters, remediating polluted soils, improving agricultural productivity, protecting crop production, and developing sensitive analytical methods is reviewed here, covering the past 17 years. The main advantages of vermicompost, considering all applications covered in this paper, comprise (i) easy acquisition, (ii) low costs, (iii) structural, chemical, and biological characteristics responsible for exceptional adsorptive capacities as well as pollutant degradation, and (iv) the promotion of biocontrol. Specifically, for wastewater decontamination, a considerable number of works have verified the adsorption of toxic metals, but the application of vermicompost is still scarce for the retention of organic compounds. Problems related to the final disposal of enriched vermicompost (after treatment steps) are often found, in spite of some successful destinations such as organic fertilizer. For decontaminating soils, the use of vermicompost is quite scarce, mainly for inorganic pollutants. In agricultural productivity and biocontrol, vermicompost imparts remarkable benefits regarding soil aggregation, plant nutrition, and the development of beneficial microorganisms against phytopathogens. Finally, the use of vermicompost in sensitive analytical methods for quantifying toxic metals is the newest application of this adsorbent. PMID:24578668

  19. An Overview of the Environmental Applicability of Vermicompost: From Wastewater Treatment to the Development of Sensitive Analytical Methods

    Directory of Open Access Journals (Sweden)

    Madson de Godoi Pereira

    2014-01-01

    Full Text Available The use of vermicompost (humified material for treating wastewaters, remediating polluted soils, improving agricultural productivity, protecting crop production, and developing sensitive analytical methods is reviewed here, covering the past 17 years. The main advantages of vermicompost, considering all applications covered in this paper, comprise (i easy acquisition, (ii low costs, (iii structural, chemical, and biological characteristics responsible for exceptional adsorptive capacities as well as pollutant degradation, and (iv the promotion of biocontrol. Specifically, for wastewater decontamination, a considerable number of works have verified the adsorption of toxic metals, but the application of vermicompost is still scarce for the retention of organic compounds. Problems related to the final disposal of enriched vermicompost (after treatment steps are often found, in spite of some successful destinations such as organic fertilizer. For decontaminating soils, the use of vermicompost is quite scarce, mainly for inorganic pollutants. In agricultural productivity and biocontrol, vermicompost imparts remarkable benefits regarding soil aggregation, plant nutrition, and the development of beneficial microorganisms against phytopathogens. Finally, the use of vermicompost in sensitive analytical methods for quantifying toxic metals is the newest application of this adsorbent.

  20. Analytical methods for determination of mycotoxins: a review.

    Science.gov (United States)

    Turner, Nicholas W; Subrahmanyam, Sreenath; Piletsky, Sergey A

    2009-01-26

    Mycotoxins are small (MW approximately 700), toxic chemical products formed as secondary metabolites by a few fungal species that readily colonise crops and contaminate them with toxins in the field or after harvest. Ochratoxins and Aflatoxins are mycotoxins of major significance and hence there has been significant research on broad range of analytical and detection techniques that could be useful and practical. Due to the variety of structures of these toxins, it is impossible to use one standard technique for analysis and/or detection. Practical requirements for high-sensitivity analysis and the need for a specialist laboratory setting create challenges for routine analysis. Several existing analytical techniques, which offer flexible and broad-based methods of analysis and in some cases detection, have been discussed in this manuscript. There are a number of methods used, of which many are lab-based, but to our knowledge there seems to be no single technique that stands out above the rest, although analytical liquid chromatography, commonly linked with mass spectroscopy is likely to be popular. This review manuscript discusses (a) sample pre-treatment methods such as liquid-liquid extraction (LLE), supercritical fluid extraction (SFE), solid phase extraction (SPE), (b) separation methods such as (TLC), high performance liquid chromatography (HPLC), gas chromatography (GC), and capillary electrophoresis (CE) and (c) others such as ELISA. Further currents trends, advantages and disadvantages and future prospects of these methods have been discussed.

  1. An analytical method for determination of fullerenes and functionalized fullerenes in soils with high performance liquid chromatography and UV detection

    International Nuclear Information System (INIS)

    Carboni, Andrea; Emke, Erik; Parsons, John R.; Kalbitz, Karsten; Voogt, Pim de

    2014-01-01

    Graphical abstract: -- Highlights: •A total of eight fullerenes can be analyzed in a single run with HPLC-UV. •The method allows the analysis of fullerenes in soil at relatively low concentrations. •The method developed is robust, highly reproducible and relatively efficient. •The method can be applied to the study of the environmental fate and toxicology of fullerenes. -- Abstract: Fullerenes are carbon-based nanomaterials expected to play a major role in emerging nanotechnology and produced at an increasing rate for industrial and household applications. In the last decade a number of novel compounds (i.e. fullerene derivatives) is being introduced into the market and specific analytical methods are needed for analytical purposes as well as environmental and safety issues. In the present work eight fullerenes (C60 and C70) and functionalized fullerenes (C60 and C70 exohedral-derivatives) were selected and a novel liquid chromatographic method was developed for their analysis with UV absorption as a method of detection. The resulting HPLC-UV method is the first one suitable for the analysis of all eight compounds. This method was applied for the analysis of fullerenes added to clayish, sandy and loess top-soils at concentrations of 20, 10 and 5 μg kg −1 and extracted with a combination of sonication and shaking extraction. The analytical method limits of detection (LoD) and limits of quantification (LoQ) were in the range of 6–10 μg L −1 and 15–24 μg L −1 respectively for the analytical solutions. The extraction from soil was highly reproducible with recoveries ranging from 47 ± 5 to 71 ± 4% whereas LoD and LoQ for all soils tested were of 3 μg kg −1 and 10 μg kg −1 respectively. No significant difference in the extraction performance was observed depending of the different soil matrices and between the different concentrations. The developed method can be applied for the study of the fate and toxicity of fullerenes in complex matrices

  2. Analytical chemistry instrumentation

    International Nuclear Information System (INIS)

    Laing, W.R.

    1986-01-01

    In nine sections, 48 chapters cover 1) analytical chemistry and the environment 2) environmental radiochemistry 3) automated instrumentation 4) advances in analytical mass spectrometry 5) fourier transform spectroscopy 6) analytical chemistry of plutonium 7) nuclear analytical chemistry 8) chemometrics and 9) nuclear fuel technology

  3. A new method of regional eco-environmental quality assessment and its application.

    Science.gov (United States)

    Wang, Xiaodan; Cao, Yingzi; Zhong, Xianghao; Gao, Pan

    2012-01-01

    Eco-environmental quality assessment (EQA) is an intricate and challenging task that must take into account numerous natural, economic, political, and social factors, which are subject to multiple conflicting criteria. In this paper, a methodological reference framework is developed for EQA that combines the fuzzy Delphi method (FDM) and fuzzy analytical hierarchy process (FAHP) with a geographic information system (GIS). The proposed method significantly improves the accuracy and reliability of evaluation results through the incorporation of fuzzy set theory. A GIS not only has the ability to store and analyze large amounts of spatial data from different sources but also provides a consistent visualization environment for displaying the input data and the results of EQA. Furthermore, unlike prior EQAs, the proposed method can support the dynamic estimation of regional eco-environmental quality by updating historical spatiotemporal data at little additional cost. A case study is presented for the western Tibetan Plateau. The study results show that worse, bad, and moderate eco-environmental quality classes comprised 16.58, 20.15, and 24.84% of the total area, respectively. Good and better eco-environmental quality classes accounted for 38.43%. This result indicates that nearly 62% of the total area is eco-environmentally vulnerable. The results verified the usefulness and feasibility of the proposed method. The EQA can also help local managers make scientifically based and effective decisions about Tibetan eco-environmental protection and land use. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  4. Big data analytics methods and applications

    CERN Document Server

    Rao, BLS; Rao, SB

    2016-01-01

    This book has a collection of articles written by Big Data experts to describe some of the cutting-edge methods and applications from their respective areas of interest, and provides the reader with a detailed overview of the field of Big Data Analytics as it is practiced today. The chapters cover technical aspects of key areas that generate and use Big Data such as management and finance; medicine and healthcare; genome, cytome and microbiome; graphs and networks; Internet of Things; Big Data standards; bench-marking of systems; and others. In addition to different applications, key algorithmic approaches such as graph partitioning, clustering and finite mixture modelling of high-dimensional data are also covered. The varied collection of themes in this volume introduces the reader to the richness of the emerging field of Big Data Analytics.

  5. An Investigation to Manufacturing Analytical Services Composition using the Analytical Target Cascading Method.

    Science.gov (United States)

    Tien, Kai-Wen; Kulvatunyou, Boonserm; Jung, Kiwook; Prabhu, Vittaldas

    2017-01-01

    As cloud computing is increasingly adopted, the trend is to offer software functions as modular services and compose them into larger, more meaningful ones. The trend is attractive to analytical problems in the manufacturing system design and performance improvement domain because 1) finding a global optimization for the system is a complex problem; and 2) sub-problems are typically compartmentalized by the organizational structure. However, solving sub-problems by independent services can result in a sub-optimal solution at the system level. This paper investigates the technique called Analytical Target Cascading (ATC) to coordinate the optimization of loosely-coupled sub-problems, each may be modularly formulated by differing departments and be solved by modular analytical services. The result demonstrates that ATC is a promising method in that it offers system-level optimal solutions that can scale up by exploiting distributed and modular executions while allowing easier management of the problem formulation.

  6. Quality assurance programs developed and implemented by the US Department of Energy's Analytical Services Program for environmental restoration and waste management activities

    International Nuclear Information System (INIS)

    Lillian, D.; Bottrell, D.

    1993-01-01

    The U.S. Department of Energy's (DOE's) Office of Environmental Restoration and Waste Management (EM) has been tasked with addressing environmental contamination and waste problems facing the Department. A key element of any environmental restoration or waste management program is environmental data. An effective and efficient sampling and analysis program is required to generate credible environmental data. The bases for DOE's EM Analytical Services Program (ASP) are contained in the charter and commitments in Secretary of Energy Notice SEN-13-89, EM program policies and requirements, and commitments to Congress and the Office of Inspector General (IG). The Congressional commitment by DOE to develop and implement an ASP was in response to concerns raised by the Chairman of the Congressional Environment, Energy, and Natural Resources Subcommittee, and the Chairman of the Congressional Oversight and Investigations Subcommittee of the Committee on Energy and Commerce, regarding the production of analytical data. The development and implementation of an ASP also satisfies the IG's audit report recommendations on environmental analytical support, including development and implementation of a national strategy for acquisition of quality sampling and analytical services. These recommendations were endorsed in Departmental positions, which further emphasize the importance of the ASP to EM's programs. In September 1990, EM formed the Laboratory Management Division (LMD) in the Office of Technology Development to provide the programmatic direction needed to establish and operate an EM-wide ASP program. In January 1992, LMD issued the open-quotes Analytical Services Program Five-Year Plan.close quotes This document described LMD's strategy to ensure the production of timely, cost-effective, and credible environmental data. This presentation describes the overall LMD Analytical Services Program and, specifically, the various QA programs

  7. An analytic data analysis method for oscillatory slug tests.

    Science.gov (United States)

    Chen, Chia-Shyun

    2006-01-01

    An analytical data analysis method is developed for slug tests in partially penetrating wells in confined or unconfined aquifers of high hydraulic conductivity. As adapted from the van der Kamp method, the determination of the hydraulic conductivity is based on the occurrence times and the displacements of the extreme points measured from the oscillatory data and their theoretical counterparts available in the literature. This method is applied to two sets of slug test response data presented by Butler et al.: one set shows slow damping with seven discernable extremities, and the other shows rapid damping with three extreme points. The estimates of the hydraulic conductivity obtained by the analytic method are in good agreement with those determined by an available curve-matching technique.

  8. A SIMPLE ANALYTICAL METHOD TO DETERMINE SOLAR ENERGETIC PARTICLES' MEAN FREE PATH

    International Nuclear Information System (INIS)

    He, H.-Q.; Qin, G.

    2011-01-01

    To obtain the mean free path of solar energetic particles (SEPs) for a solar event, one usually has to fit time profiles of both flux and anisotropy from spacecraft observations to numerical simulations of SEPs' transport processes. This method can be called a simulation method. But a reasonably good fitting needs a lot of simulations, which demand a large amount of calculation resources. Sometimes, it is necessary to find an easy way to obtain the mean free path of SEPs quickly, for example, in space weather practice. Recently, Shalchi et al. provided an approximate analytical formula of SEPs' anisotropy time profile as a function of particles' mean free path for impulsive events. In this paper, we determine SEPs' mean free path by fitting the anisotropy time profiles from Shalchi et al.'s analytical formula to spacecraft observations. This new method can be called an analytical method. In addition, we obtain SEPs' mean free path with the traditional simulation methods. Finally, we compare the mean free path obtained with the simulation method to that of the analytical method to show that the analytical method, with some minor modifications, can give us a good, quick approximation of SEPs' mean free path for impulsive events.

  9. Environmental Risk Assessment System for Phosphogypsum Tailing Dams

    OpenAIRE

    Xin Sun; Ping Ning; Xiaolong Tang; Honghong Yi; Kai Li; Lianbi Zhou; Xianmang Xu

    2013-01-01

    This paper may be of particular interest to the readers as it provides a new environmental risk assessment system for phosphogypsum tailing dams. In this paper, we studied the phosphogypsum tailing dams which include characteristics of the pollution source, environmental risk characteristics and evaluation requirements to identify the applicable environmental risk assessment methods. Two analytical methods, that is, the analytic hierarchy process (AHP) and fuzzy logic, were used to handle the...

  10. Atomic and Nuclear Analytical Methods XRF, Mössbauer, XPS, NAA and Ion-Beam Spectroscopic Techniques

    CERN Document Server

    Verma, H R

    2007-01-01

    This book is a blend of analytical methods based on the phenomenon of atomic and nuclear physics. It comprises comprehensive presentations about X-ray Fluorescence (XRF), Mössbauer Spectroscopy (MS), X-ray Photoelectron Spectroscopy (XPS), Neutron- Activation Analysis (NAA), Particle Induced X-ray Emission Analysis (PIXE), Rutherford Backscattering Analysis (RBS), Elastic Recoil Detection (ERD), Nuclear Reaction Analysis (NRA), Particle Induced Gamma-ray Emission Analysis (PIGE), and Accelerator Mass Spectrometry (AMS). These techniques are commonly applied in the fields of medicine, biology, environmental studies, archaeology or geology et al. and pursued in major international research laboratories.

  11. Critical node treatment in the analytic function expansion method for Pin Power Reconstruction

    International Nuclear Information System (INIS)

    Gao, Z.; Xu, Y.; Downar, T.

    2013-01-01

    Pin Power Reconstruction (PPR) was implemented in PARCS using the eight term analytic function expansion method (AFEN). This method has been demonstrated to be both accurate and efficient. However, similar to all the methods involving analytic functions, such as the analytic node method (ANM) and AFEN for nodal solution, the use of AFEN for PPR also has potential numerical issue with critical nodes. The conventional analytic functions are trigonometric or hyperbolic sine or cosine functions with an angular frequency proportional to buckling. For a critic al node the buckling is zero and the sine functions becomes zero, and the cosine function become unity. In this case, the eight terms of the analytic functions are no longer distinguishable from ea ch other which makes their corresponding coefficients can no longer be determined uniquely. The mode flux distribution of critical node can be linear while the conventional analytic functions can only express a uniform distribution. If there is critical or near critical node in a plane, the reconstructed pin power distribution is often be shown negative or very large values using the conventional method. In this paper, we propose a new method to avoid the numerical problem wit h critical nodes which uses modified trigonometric or hyperbolic sine functions which are the ratio of trigonometric or hyperbolic sine and its angular frequency. If there are no critical or near critical nodes present, the new pin power reconstruction method with modified analytic functions are equivalent to the conventional analytic functions. The new method is demonstrated using the L336C5 benchmark problem. (authors)

  12. Critical node treatment in the analytic function expansion method for Pin Power Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Z. [Rice University, MS 318, 6100 Main Street, Houston, TX 77005 (United States); Xu, Y. [Argonne National Laboratory, 9700 South Case Ave., Argonne, IL 60439 (United States); Downar, T. [Department of Nuclear Engineering, University of Michigan, 2355 Bonisteel blvd., Ann Arbor, MI 48109 (United States)

    2013-07-01

    Pin Power Reconstruction (PPR) was implemented in PARCS using the eight term analytic function expansion method (AFEN). This method has been demonstrated to be both accurate and efficient. However, similar to all the methods involving analytic functions, such as the analytic node method (ANM) and AFEN for nodal solution, the use of AFEN for PPR also has potential numerical issue with critical nodes. The conventional analytic functions are trigonometric or hyperbolic sine or cosine functions with an angular frequency proportional to buckling. For a critic al node the buckling is zero and the sine functions becomes zero, and the cosine function become unity. In this case, the eight terms of the analytic functions are no longer distinguishable from ea ch other which makes their corresponding coefficients can no longer be determined uniquely. The mode flux distribution of critical node can be linear while the conventional analytic functions can only express a uniform distribution. If there is critical or near critical node in a plane, the reconstructed pin power distribution is often be shown negative or very large values using the conventional method. In this paper, we propose a new method to avoid the numerical problem wit h critical nodes which uses modified trigonometric or hyperbolic sine functions which are the ratio of trigonometric or hyperbolic sine and its angular frequency. If there are no critical or near critical nodes present, the new pin power reconstruction method with modified analytic functions are equivalent to the conventional analytic functions. The new method is demonstrated using the L336C5 benchmark problem. (authors)

  13. An Analytic Network Process approach for the environmental aspect selection problem — A case study for a hand blender

    Energy Technology Data Exchange (ETDEWEB)

    Bereketli Zafeirakopoulos, Ilke, E-mail: ibereketli@gsu.edu.tr; Erol Genevois, Mujde, E-mail: merol@gsu.edu.tr

    2015-09-15

    Life Cycle Assessment is a tool to assess, in a systematic way, the environmental aspects and its potential environmental impacts and resources used throughout a product's life cycle. It is widely accepted and considered as one of the most powerful tools to support decision-making processes used in ecodesign and sustainable production in order to learn about the most problematic parts and life cycle phases of a product and to have a projection for future improvements. However, since Life Cycle Assessment is a cost and time intensive method, companies do not intend to carry out a full version of it, except for large corporate ones. Especially for small and medium sized enterprises, which do not have enough budget for and knowledge on sustainable production and ecodesign approaches, focusing only on the most important possible environmental aspect is unavoidable. In this direction, finding the right environmental aspect to work on is crucial for the companies. In this study, a multi-criteria decision-making methodology, Analytic Network Process is proposed to select the most relevant environmental aspect. The proposed methodology aims at providing a simplified environmental assessment to producers. It is applied for a hand blender, which is a member of the Electrical and Electronic Equipment family. The decision criteria for the environmental aspects and relations of dependence are defined. The evaluation is made by the Analytic Network Process in order to create a realistic approach to inter-dependencies among the criteria. The results are computed via the Super Decisions software. Finally, it is observed that the procedure is completed in less time, with less data, with less cost and in a less subjective way than conventional approaches. - Highlights: • We present a simplified environmental assessment methodology to support LCA. • ANP is proposed to select the most relevant environmental aspect. • ANP deals well with the interdependencies between aspects

  14. An Analytic Network Process approach for the environmental aspect selection problem — A case study for a hand blender

    International Nuclear Information System (INIS)

    Bereketli Zafeirakopoulos, Ilke; Erol Genevois, Mujde

    2015-01-01

    Life Cycle Assessment is a tool to assess, in a systematic way, the environmental aspects and its potential environmental impacts and resources used throughout a product's life cycle. It is widely accepted and considered as one of the most powerful tools to support decision-making processes used in ecodesign and sustainable production in order to learn about the most problematic parts and life cycle phases of a product and to have a projection for future improvements. However, since Life Cycle Assessment is a cost and time intensive method, companies do not intend to carry out a full version of it, except for large corporate ones. Especially for small and medium sized enterprises, which do not have enough budget for and knowledge on sustainable production and ecodesign approaches, focusing only on the most important possible environmental aspect is unavoidable. In this direction, finding the right environmental aspect to work on is crucial for the companies. In this study, a multi-criteria decision-making methodology, Analytic Network Process is proposed to select the most relevant environmental aspect. The proposed methodology aims at providing a simplified environmental assessment to producers. It is applied for a hand blender, which is a member of the Electrical and Electronic Equipment family. The decision criteria for the environmental aspects and relations of dependence are defined. The evaluation is made by the Analytic Network Process in order to create a realistic approach to inter-dependencies among the criteria. The results are computed via the Super Decisions software. Finally, it is observed that the procedure is completed in less time, with less data, with less cost and in a less subjective way than conventional approaches. - Highlights: • We present a simplified environmental assessment methodology to support LCA. • ANP is proposed to select the most relevant environmental aspect. • ANP deals well with the interdependencies between aspects

  15. Results of an interlaboratory comparison of analytical methods for contaminants of emerging concern in water.

    Science.gov (United States)

    Vanderford, Brett J; Drewes, Jörg E; Eaton, Andrew; Guo, Yingbo C; Haghani, Ali; Hoppe-Jones, Christiane; Schluesener, Michael P; Snyder, Shane A; Ternes, Thomas; Wood, Curtis J

    2014-01-07

    An evaluation of existing analytical methods used to measure contaminants of emerging concern (CECs) was performed through an interlaboratory comparison involving 25 research and commercial laboratories. In total, 52 methods were used in the single-blind study to determine method accuracy and comparability for 22 target compounds, including pharmaceuticals, personal care products, and steroid hormones, all at ng/L levels in surface and drinking water. Method biases ranged from caffeine, NP, OP, and triclosan had false positive rates >15%. In addition, some methods reported false positives for 17β-estradiol and 17α-ethynylestradiol in unspiked drinking water and deionized water, respectively, at levels higher than published predicted no-effect concentrations for these compounds in the environment. False negative rates were also generally contamination, misinterpretation of background interferences, and/or inappropriate setting of detection/quantification levels for analysis at low ng/L levels. The results of both comparisons were collectively assessed to identify parameters that resulted in the best overall method performance. Liquid chromatography-tandem mass spectrometry coupled with the calibration technique of isotope dilution were able to accurately quantify most compounds with an average bias of <10% for both matrixes. These findings suggest that this method of analysis is suitable at environmentally relevant levels for most of the compounds studied. This work underscores the need for robust, standardized analytical methods for CECs to improve data quality, increase comparability between studies, and help reduce false positive and false negative rates.

  16. Environmental and economic assessment methods for waste management decision-support: possibilities and limitations.

    Science.gov (United States)

    Finnveden, Göran; Björklund, Anna; Moberg, Asa; Ekvall, Tomas

    2007-06-01

    A large number of methods and approaches that can be used for supporting waste management decisions at different levels in society have been developed. In this paper an overview of methods is provided and preliminary guidelines for the choice of methods are presented. The methods introduced include: Environmental Impact Assessment, Strategic Environmental Assessment, Life Cycle Assessment, Cost-Benefit Analysis, Cost-effectiveness Analysis, Life-cycle Costing, Risk Assessment, Material Flow Accounting, Substance Flow Analysis, Energy Analysis, Exergy Analysis, Entropy Analysis, Environmental Management Systems, and Environmental Auditing. The characteristics used are the types of impacts included, the objects under study and whether the method is procedural or analytical. The different methods can be described as systems analysis methods. Waste management systems thinking is receiving increasing attention. This is, for example, evidenced by the suggested thematic strategy on waste by the European Commission where life-cycle analysis and life-cycle thinking get prominent positions. Indeed, life-cycle analyses have been shown to provide policy-relevant and consistent results. However, it is also clear that the studies will always be open to criticism since they are simplifications of reality and include uncertainties. This is something all systems analysis methods have in common. Assumptions can be challenged and it may be difficult to generalize from case studies to policies. This suggests that if decisions are going to be made, they are likely to be made on a less than perfect basis.

  17. International Congress on Analytical Chemistry. Abstracts. V. 2

    International Nuclear Information System (INIS)

    1997-01-01

    The collection of materials of the international congress on analytical chemistry taken place in Moscow in June 1997 is presented. The main directs of investigations are elucidated in such regions of analytical chemistry as quantitative and qualitative chemical analysis, sample preparation, express test methods of environmental and biological materials, clinical analysis, analysis of food and agricultural products

  18. International Congress on Analytical Chemistry. Abstracts. V. 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    The collection of materials of the international congress on analytical chemistry taken place in Moscow in June 1997 is presented. The main directs of investigations are elucidated in such regions of analytical chemistry as quantitative and qualitative chemical analysis, sample preparation, express test methods of environmental and biological materials, clinical analysis, analysis of food and agricultural products

  19. Health-safety and environmental risk assessment of power plants using multi criteria decision making method

    Directory of Open Access Journals (Sweden)

    Jozi Ali Seyed

    2011-01-01

    Full Text Available Growing importance of environmental issues at global and regional levels including pollution of water, air etc. as well as the outcomes such as global warming and climate change has led to being considered environmental aspects as effective factors for power generation. Study ahead, aims at examination of risks resulting from activities of Yazd Combined Cycle Power Plant located in Iran. Method applied in the research is analytical hierarchy process. After identification of factors causing risk, the analytical hierarchy structure of the power plant risks were designed and weight of the criteria and sub-criteria were calculated by intensity probability product using Eigenvector Method and EXPERT CHOICE Software as well. Results indicate that in technological, health-safety, biophysical and socio economic sections of the power plant, factors influenced by the power plant activities like fire and explosion, hearing loss, quantity of groundwater, power generation are among the most important factors causing risk in the power plant. The drop in underground water levels is the most important natural consequence influenced on Yazd Combined Cycle Power Plant.

  20. Studies on analytical method and nondestructive measuring method on the sensitization of austenitic stainless steels

    International Nuclear Information System (INIS)

    Onimura, Kichiro; Arioka, Koji; Horai, Manabu; Noguchi, Shigeru.

    1982-03-01

    Austenitic stainless steels are widely used as structural materials for the machine and equipment of various kinds of plants, such as thermal power, nuclear power, and chemical plants. The machines and equipment using this kind of material, however, have the possibility of suffering corrosion damage while in service, and these damages are considered to be largely due to the sensitization of the material in sometimes. So, it is necessary to develop an analytical method for grasping the sensitization of the material more in detail and a quantitative nondestructive measuring method which is applicable to various kinds of structures in order to prevent the corrosion damage. From the above viewpoint, studies have been made on the analytical method based on the theory of diffusion of chromium in austenitic stainless steels and on Electro-Potentiokinetics Reactivation Method (EPR Method) as a nondestructive measuring method, using 304 and 316 austenitic stainless steels having different carbon contents in base metals. This paper introduces the results of EPR test on the sensitization of austenitic stainless steels and the correlation between analytical and experimental results. (author)

  1. Analytical resource assessment method for continuous (unconventional) oil and gas accumulations - The "ACCESS" Method

    Science.gov (United States)

    Crovelli, Robert A.; revised by Charpentier, Ronald R.

    2012-01-01

    The U.S. Geological Survey (USGS) periodically assesses petroleum resources of areas within the United States and the world. The purpose of this report is to explain the development of an analytic probabilistic method and spreadsheet software system called Analytic Cell-Based Continuous Energy Spreadsheet System (ACCESS). The ACCESS method is based upon mathematical equations derived from probability theory. The ACCESS spreadsheet can be used to calculate estimates of the undeveloped oil, gas, and NGL (natural gas liquids) resources in a continuous-type assessment unit. An assessment unit is a mappable volume of rock in a total petroleum system. In this report, the geologic assessment model is defined first, the analytic probabilistic method is described second, and the spreadsheet ACCESS is described third. In this revised version of Open-File Report 00-044 , the text has been updated to reflect modifications that were made to the ACCESS program. Two versions of the program are added as appendixes.

  2. Propulsion and launching analysis of variable-mass rockets by analytical methods

    Directory of Open Access Journals (Sweden)

    D.D. Ganji

    2013-09-01

    Full Text Available In this study, applications of some analytical methods on nonlinear equation of the launching of a rocket with variable mass are investigated. Differential transformation method (DTM, homotopy perturbation method (HPM and least square method (LSM were applied and their results are compared with numerical solution. An excellent agreement with analytical methods and numerical ones is observed in the results and this reveals that analytical methods are effective and convenient. Also a parametric study is performed here which includes the effect of exhaust velocity (Ce, burn rate (BR of fuel and diameter of cylindrical rocket (d on the motion of a sample rocket, and contours for showing the sensitivity of these parameters are plotted. The main results indicate that the rocket velocity and altitude are increased with increasing the Ce and BR and decreased with increasing the rocket diameter and drag coefficient.

  3. Analytical method developed for measurement of dialkylphosphate metabolites in urine collected from children non-occupationally exposed to organophosphate pesticides in an agricultural community in Thailand.

    Science.gov (United States)

    Petchuay, Chidhathai; Thoumsang, Somkiet; Visuthismajarn, Parichart; Vitayavirasak, Banjong; Buckley, Brian; Hore, Paromita; Borjan, Marija; Robson, Mark

    2008-10-01

    There has been increasing concern in regards to organophosphate (OP) pesticide exposure among farm workers and their families in Thailand's agricultural areas. Therefore, the development of an analytical method for estimating OP pesticide exposure is necessary to allow for monitoring of OP pesticide exposures within these populations. This paper describes an analytical method developed to measure dialkylphosphate (DAP) metabolites in urine. The methods in this study are important in the biological monitoring of OP metabolites in agricultural families in Thailand and can be used as an initial guidance procedure in any environmental toxicological laboratory in Thailand.

  4. Biodiesel Analytical Methods: August 2002--January 2004

    Energy Technology Data Exchange (ETDEWEB)

    Van Gerpen, J.; Shanks, B.; Pruszko, R.; Clements, D.; Knothe, G.

    2004-07-01

    Biodiesel is an alternative fuel for diesel engines that is receiving great attention worldwide. The material contained in this book is intended to provide the reader with information about biodiesel engines and fuels, analytical methods used to measure fuel properties, and specifications for biodiesel quality control.

  5. A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.

    Science.gov (United States)

    Yang, Harry; Zhang, Jianchun

    2015-01-01

    The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current

  6. ICP-MS: Analytical Method for Identification and Detection of Elemental Impurities.

    Science.gov (United States)

    Mittal, Mohini; Kumar, Kapil; Anghore, Durgadas; Rawal, Ravindra K

    2017-01-01

    Aim of this article is to review and discuss the currently used quantitative analytical method ICP-MS, which is used for quality control of pharmaceutical products. ICP-MS technique has several applications such as determination of single elements, multi element analysis in synthetic drugs, heavy metals in environmental water, trace element content of selected fertilizers and dairy manures. ICP-MS is also used for determination of toxic and essential elements in different varieties of food samples and metal pollutant present in the environment. The pharmaceuticals may generate impurities at various stages of development, transportation and storage which make them risky to be administered. Thus, it is essential that these impurities must be detected and quantified. ICP-MS plays an important function in the recognition and revealing of elemental impurities. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Approximate analytical methods for solving ordinary differential equations

    CERN Document Server

    Radhika, TSL; Rani, T Raja

    2015-01-01

    Approximate Analytical Methods for Solving Ordinary Differential Equations (ODEs) is the first book to present all of the available approximate methods for solving ODEs, eliminating the need to wade through multiple books and articles. It covers both well-established techniques and recently developed procedures, including the classical series solution method, diverse perturbation methods, pioneering asymptotic methods, and the latest homotopy methods.The book is suitable not only for mathematicians and engineers but also for biologists, physicists, and economists. It gives a complete descripti

  8. Examination of fast reactor fuels, FBR analytical quality assurance standards and methods, and analytical methods development: irradiation tests. Progress report, April 1--June 30, 1976, and FY 1976

    International Nuclear Information System (INIS)

    Baker, R.D.

    1976-08-01

    Characterization of unirradiated and irradiated LMFBR fuels by analytical chemistry methods will continue, and additional methods will be modified and mechanized for hot cell application. Macro- and microexaminations will be made on fuel and cladding using the shielded electron microprobe, emission spectrograph, radiochemistry, gamma scanner, mass spectrometers, and other analytical facilities. New capabilities will be developed in gamma scanning, analyses to assess spatial distributions of fuel and fission products, mass spectrometric measurements of burnup and fission gas constituents and other chemical analyses. Microstructural analyses of unirradiated and irradiated materials will continue using optical and electron microscopy and autoradiographic and x-ray techniques. Analytical quality assurance standards tasks are designed to assure the quality of the chemical characterizations necessary to evaluate reactor components relative to specifications. Tasks include: (1) the preparation and distribution of calibration materials and quality control samples for use in quality assurance surveillance programs, (2) the development of and the guidance in the use of quality assurance programs for sampling and analysis, (3) the development of improved methods of analysis, and (4) the preparation of continuously updated analytical method manuals. Reliable analytical methods development for the measurement of burnup, oxygen-to-metal (O/M) ratio, and various gases in irradiated fuels is described

  9. SPANDOM - source projection analytic nodal discrete ordinates method

    International Nuclear Information System (INIS)

    Kim, Tae Hyeong; Cho, Nam Zin

    1994-01-01

    We describe a new discrete ordinates nodal method for the two-dimensional transport equation. We solve the discrete ordinates equation analytically after the source term is projected and represented in polynomials. The method is applied to two fast reactor benchmark problems and compared with the TWOHEX code. The results indicate that the present method accurately predicts not only multiplication factor but also flux distribution

  10. Transport methods: general. 1. The Analytical Monte Carlo Method for Radiation Transport Calculations

    International Nuclear Information System (INIS)

    Martin, William R.; Brown, Forrest B.

    2001-01-01

    We present an alternative Monte Carlo method for solving the coupled equations of radiation transport and material energy. This method is based on incorporating the analytical solution to the material energy equation directly into the Monte Carlo simulation for the radiation intensity. This method, which we call the Analytical Monte Carlo (AMC) method, differs from the well known Implicit Monte Carlo (IMC) method of Fleck and Cummings because there is no discretization of the material energy equation since it is solved as a by-product of the Monte Carlo simulation of the transport equation. Our method also differs from the method recently proposed by Ahrens and Larsen since they use Monte Carlo to solve both equations, while we are solving only the radiation transport equation with Monte Carlo, albeit with effective sources and cross sections to represent the emission sources. Our method bears some similarity to a method developed and implemented by Carter and Forest nearly three decades ago, but there are substantive differences. We have implemented our method in a simple zero-dimensional Monte Carlo code to test the feasibility of the method, and the preliminary results are very promising, justifying further extension to more realistic geometries. (authors)

  11. A field study of selected U.S. Geological Survey analytical methods for measuring pesticides in filtered stream water, June - September 2012

    Science.gov (United States)

    Martin, Jeffrey D.; Norman, Julia E.; Sandstrom, Mark W.; Rose, Claire E.

    2017-09-06

    U.S. Geological Survey monitoring programs extensively used two analytical methods, gas chromatography/mass spectrometry and liquid chromatography/mass spectrometry, to measure pesticides in filtered water samples during 1992–2012. In October 2012, the monitoring programs began using direct aqueous-injection liquid chromatography tandem mass spectrometry as a new analytical method for pesticides. The change in analytical methods, however, has the potential to inadvertently introduce bias in analysis of datasets that span the change.A field study was designed to document performance of the new method in a variety of stream-water matrices and to quantify any potential changes in measurement bias or variability that could be attributed to changes in analytical methods. The goals of the field study were to (1) summarize performance (bias and variability of pesticide recovery) of the new method in a variety of stream-water matrices; (2) compare performance of the new method in laboratory blank water (laboratory reagent spikes) to that in a variety of stream-water matrices; (3) compare performance (analytical recovery) of the new method to that of the old methods in a variety of stream-water matrices; (4) compare pesticide detections and concentrations measured by the new method to those of the old methods in a variety of stream-water matrices; (5) compare contamination measured by field blank water samples in old and new methods; (6) summarize the variability of pesticide detections and concentrations measured by the new method in field duplicate water samples; and (7) identify matrix characteristics of environmental water samples that adversely influence the performance of the new method. Stream-water samples and a variety of field quality-control samples were collected at 48 sites in the U.S. Geological Survey monitoring networks during June–September 2012. Stream sites were located across the United States and included sites in agricultural and urban land

  12. Quality assurance programs developed and implemented by the US Department of Energy`s Analytical Services Program for environmental restoration and waste management activities

    Energy Technology Data Exchange (ETDEWEB)

    Lillian, D.; Bottrell, D. [Dept. of Energy, Germntown, MD (United States)

    1993-12-31

    The U.S. Department of Energy`s (DOE`s) Office of Environmental Restoration and Waste Management (EM) has been tasked with addressing environmental contamination and waste problems facing the Department. A key element of any environmental restoration or waste management program is environmental data. An effective and efficient sampling and analysis program is required to generate credible environmental data. The bases for DOE`s EM Analytical Services Program (ASP) are contained in the charter and commitments in Secretary of Energy Notice SEN-13-89, EM program policies and requirements, and commitments to Congress and the Office of Inspector General (IG). The Congressional commitment by DOE to develop and implement an ASP was in response to concerns raised by the Chairman of the Congressional Environment, Energy, and Natural Resources Subcommittee, and the Chairman of the Congressional Oversight and Investigations Subcommittee of the Committee on Energy and Commerce, regarding the production of analytical data. The development and implementation of an ASP also satisfies the IG`s audit report recommendations on environmental analytical support, including development and implementation of a national strategy for acquisition of quality sampling and analytical services. These recommendations were endorsed in Departmental positions, which further emphasize the importance of the ASP to EM`s programs. In September 1990, EM formed the Laboratory Management Division (LMD) in the Office of Technology Development to provide the programmatic direction needed to establish and operate an EM-wide ASP program. In January 1992, LMD issued the {open_quotes}Analytical Services Program Five-Year Plan.{close_quotes} This document described LMD`s strategy to ensure the production of timely, cost-effective, and credible environmental data. This presentation describes the overall LMD Analytical Services Program and, specifically, the various QA programs.

  13. Analytical method for optimization of maintenance policy based on available system failure data

    International Nuclear Information System (INIS)

    Coria, V.H.; Maximov, S.; Rivas-Dávalos, F.; Melchor, C.L.; Guardado, J.L.

    2015-01-01

    An analytical optimization method for preventive maintenance (PM) policy with minimal repair at failure, periodic maintenance, and replacement is proposed for systems with historical failure time data influenced by a current PM policy. The method includes a new imperfect PM model based on Weibull distribution and incorporates the current maintenance interval T 0 and the optimal maintenance interval T to be found. The Weibull parameters are analytically estimated using maximum likelihood estimation. Based on this model, the optimal number of PM and the optimal maintenance interval for minimizing the expected cost over an infinite time horizon are also analytically determined. A number of examples are presented involving different failure time data and current maintenance intervals to analyze how the proposed analytical optimization method for periodic PM policy performances in response to changes in the distribution of the failure data and the current maintenance interval. - Highlights: • An analytical optimization method for preventive maintenance (PM) policy is proposed. • A new imperfect PM model is developed. • The Weibull parameters are analytically estimated using maximum likelihood. • The optimal maintenance interval and number of PM are also analytically determined. • The model is validated by several numerical examples

  14. New Analytical Method for the Determination of Metronidazole in ...

    African Journals Online (AJOL)

    New Analytical Method for the Determination of Metronidazole in Human Plasma: Application to Bioequivalence Study. ... Methods: Metronidazole was extracted from human plasma through one step of ... http://dx.doi.org/10.4314/tjpr.v11i5.14.

  15. Development and validation of analytical methods for dietary supplements

    International Nuclear Information System (INIS)

    Sullivan, Darryl; Crowley, Richard

    2006-01-01

    The expanding use of innovative botanical ingredients in dietary supplements and foods has resulted in a flurry of research aimed at the development and validation of analytical methods for accurate measurement of active ingredients. The pressing need for these methods is being met through an expansive collaborative initiative involving industry, government, and analytical organizations. This effort has resulted in the validation of several important assays as well as important advances in the method engineering procedures which have improved the efficiency of the process. The initiative has also allowed researchers to hurdle many of the barricades that have hindered accurate analysis such as the lack of reference standards and comparative data. As the availability for nutraceutical products continues to increase these methods will provide consumers and regulators with the scientific information needed to assure safety and dependable labeling

  16. Performance of analytical methods for tomographic gamma scanning

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.

    1997-01-01

    The use of gamma-ray computerized tomography for nondestructive assay of radioactive materials has led to the development of specialized analytical methods. Over the past few years, Los Alamos has developed and implemented a computer code, called ARC-TGS, for the analysis of data obtained by tomographic gamma scanning (TGS). ARC-TGS reduces TGS transmission and emission tomographic data, providing the user with images of the sample contents, the activity or mass of selected radionuclides, and an estimate of the uncertainty in the measured quantities. The results provided by ARC-TGS can be corrected for self-attenuation when the isotope of interest emits more than one gamma-ray. In addition, ARC-TGS provides information needed to estimate TGS quantification limits and to estimate the scan time needed to screen for small amounts of radioactivity. In this report, an overview of the analytical methods used by ARC-TGS is presented along with an assessment of the performance of these methods for TGS

  17. Proceedings of the 11. ENQA: Brazilian meeting on analytical chemistry. Challenges for analytical chemistry in the 21st century. Book of Abstracts

    International Nuclear Information System (INIS)

    2001-01-01

    The 11th National Meeting on Analytical Chemistry was held from 18 to 21 September, 2001 at the Convention Center of UNICAMP, with the theme Challenges for Analytical Chemistry in the 21st Century. This meeting have discussed on the development of new methods and analytical tools needed to solve new challenges. The papers presented topics related to the different sub-areas of Analytical Chemistry such as Environmental Chemistry; Chemiometry techniques; X-ray Fluorescence Analysis; Spectroscopy; Separation Processes; Electroanalytic Chemistry and others. Were also included lectures on the Past and Future of Analytical Chemistry and on Ethics in Science

  18. Aplikasi Analytical Hierarchy Process Pada Pemilihan Metode Analisis Zat Organik Dalam Air

    Directory of Open Access Journals (Sweden)

    Dino Rimantho

    2016-07-01

    Full Text Available Water is one of the food products analyzed in water chemistry and environmental laboratories. One of the parameters analyzed are organic substances. The number of samples that were not comparable with the analytical skills can cause delays in test results. Analytical Hierarchy Process applied to evaluate the analytical methods used. Alternative methods tested include titrimetric method, spectrophotometry, and total organic carbon (TOC. Respondents consisted of deputy technical manager, laboratory coordinator, and two senior analysts. Alternative results obtained are methods of TOC. Proposed improvements alternative analytical method based on the results obtained, the method of the TOC with a 10-15 minute analysis time and use of CRM to the validity of the analysis results.

  19. Analytic continuation of quantum Monte Carlo data. Stochastic sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Ghanem, Khaldoon; Koch, Erik [Institute for Advanced Simulation, Forschungszentrum Juelich, 52425 Juelich (Germany)

    2016-07-01

    We apply Bayesian inference to the analytic continuation of quantum Monte Carlo (QMC) data from the imaginary axis to the real axis. Demanding a proper functional Bayesian formulation of any analytic continuation method leads naturally to the stochastic sampling method (StochS) as the Bayesian method with the simplest prior, while it excludes the maximum entropy method and Tikhonov regularization. We present a new efficient algorithm for performing StochS that reduces computational times by orders of magnitude in comparison to earlier StochS methods. We apply the new algorithm to a wide variety of typical test cases: spectral functions and susceptibilities from DMFT and lattice QMC calculations. Results show that StochS performs well and is able to resolve sharp features in the spectrum.

  20. Learning from environmental data: Methods for analysis of forest nutrition time series

    Energy Technology Data Exchange (ETDEWEB)

    Sulkava, M. (Helsinki Univ. of Technology, Espoo (Finland). Computer and Information Science)

    2008-07-01

    Data analysis methods play an important role in increasing our knowledge of the environment as the amount of data measured from the environment increases. This thesis fits under the scope of environmental informatics and environmental statistics. They are fields, in which data analysis methods are developed and applied for the analysis of environmental data. The environmental data studied in this thesis are time series of nutrient concentration measurements of pine and spruce needles. In addition, there are data of laboratory quality and related environmental factors, such as the weather and atmospheric depositions. The most important methods used for the analysis of the data are based on the self-organizing map and linear regression models. First, a new clustering algorithm of the self-organizing map is proposed. It is found to provide better results than two other methods for clustering of the self-organizing map. The algorithm is used to divide the nutrient concentration data into clusters, and the result is evaluated by environmental scientists. Based on the clustering, the temporal development of the forest nutrition is modeled and the effect of nitrogen and sulfur deposition on the foliar mineral composition is assessed. Second, regression models are used for studying how much environmental factors and properties of the needles affect the changes in the nutrient concentrations of the needles between their first and second year of existence. The aim is to build understandable models with good prediction capabilities. Sparse regression models are found to outperform more traditional regression models in this task. Third, fusion of laboratory quality data from different sources is performed to estimate the precisions of the analytical methods. Weighted regression models are used to quantify how much the precision of observations can affect the time needed to detect a trend in environmental time series. The results of power analysis show that improving the

  1. Five-point Element Scheme of Finite Analytic Method for Unsteady Groundwater Flow

    Institute of Scientific and Technical Information of China (English)

    Xiang Bo; Mi Xiao; Ji Changming; Luo Qingsong

    2007-01-01

    In order to improve the finite analytic method's adaptability for irregular unit, by using coordinates rotation technique this paper establishes a five-point element scheme of finite analytic method. It not only solves unsteady groundwater flow equation but also gives the boundary condition. This method can be used to calculate the three typical questions of groundwater. By compared with predecessor's computed result, the result of this method is more satisfactory.

  2. Directory of Analytical Methods, Department 1820

    International Nuclear Information System (INIS)

    Whan, R.E.

    1986-01-01

    The Materials Characterization Department performs chemical, physical, and thermophysical analyses in support of programs throughout the Laboratories. The department has a wide variety of techniques and instruments staffed by experienced personnel available for these analyses, and we strive to maintain near state-of-the-art technology by continued updates. We have prepared this Directory of Analytical Methods in order to acquaint you with our capabilities and to help you identify personnel who can assist with your analytical needs. The descriptions of the various capabilities are requester-oriented and have been limited in length and detail. Emphasis has been placed on applications and limitations with notations of estimated analysis time and alternative or related techniques. A short, simplified discussion of underlying principles is also presented along with references if more detail is desired. The contents of this document have been organized in the order: bulky analysis, microanalysis, surface analysis, optical and thermal property measurements

  3. Temperature-controlled micro-TLC: a versatile green chemistry and fast analytical tool for separation and preliminary screening of steroids fraction from biological and environmental samples.

    Science.gov (United States)

    Zarzycki, Paweł K; Slączka, Magdalena M; Zarzycka, Magdalena B; Bartoszuk, Małgorzata A; Włodarczyk, Elżbieta; Baran, Michał J

    2011-11-01

    This paper is a continuation of our previous research focusing on development of micro-TLC methodology under temperature-controlled conditions. The main goal of present paper is to demonstrate separation and detection capability of micro-TLC technique involving simple analytical protocols without multi-steps sample pre-purification. One of the advantages of planar chromatography over its column counterpart is that each TLC run can be performed using non-previously used stationary phase. Therefore, it is possible to fractionate or separate complex samples characterized by heavy biological matrix loading. In present studies components of interest, mainly steroids, were isolated from biological samples like fish bile using single pre-treatment steps involving direct organic liquid extraction and/or deproteinization by freeze-drying method. Low-molecular mass compounds with polarity ranging from estetrol to progesterone derived from the environmental samples (lake water, untreated and treated sewage waters) were concentrated using optimized solid-phase extraction (SPE). Specific bands patterns for samples derived from surface water of the Middle Pomerania in northern part of Poland can be easily observed on obtained micro-TLC chromatograms. This approach can be useful as simple and non-expensive complementary method for fast control and screening of treated sewage water discharged by the municipal wastewater treatment plants. Moreover, our experimental results show the potential of micro-TLC as an efficient tool for retention measurements of a wide range of steroids under reversed-phase (RP) chromatographic conditions. These data can be used for further optimalization of SPE or HPLC systems working under RP conditions. Furthermore, we also demonstrated that micro-TLC based analytical approach can be applied as an effective method for the internal standard (IS) substance search. Generally, described methodology can be applied for fast fractionation or screening of the

  4. Methods of analytical check for highly pure tungsten

    International Nuclear Information System (INIS)

    Miklin, D.G.; Karpov, Yu.A.; Orlova, V.A.

    1993-01-01

    The review is devoted to the methods of high-purity tungsten analysis. Current trends in the development of this branch of analytical chemistry are considered. Application of both instrument mass-spectrometry analysis and optico-spectral, activation methods and mass-spectrometry ones with inductively-bound plasma in combination with preliminary isolation of the basis and impurity concentration is expected to be the most actual

  5. Development of analytical method for PBDEs and PBDDs/DFs in environmental matrices and some chemical formulations

    Energy Technology Data Exchange (ETDEWEB)

    Hanari, N.; Okazawa, T.; Yamashita, N. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Guruge, K. [National Institute of Animal Health (NIAH), Tsukuba (Japan); Falandysz, J. [Gdansk Univ. (Poland)

    2004-09-15

    Brominated flame retardants (BFRs) are environmentally and toxicologically hazardous compounds amongst many of chemicals used to reduce inherent fire hazards in a variety of goods. Polybrominated diphenyl ethers (PBDEs) are widely used flame retardants in textile and plastic materials and their content can be up to 10-30% of the product weight as is found for polyurethane foams. The technical PBDE products become available at the market as pentaBDE, octaBDE and decaBDE formulation. A combustion of the wastes containing PBDEs as well as thermal destruction of other BFR-containing materials may lead to the formation of another and considered to be highly toxic compounds such as polybrominated dibenzo-p-dioxins (PBDDs) and dibenzofurans (PBDFs). Some of PBDE congeners were found to be liable for debromination and photodegradation under a real environmental condition but also during chemical laboratory analysis. Additionally, co-occurrence of PBDDs/DFs and PBDEs can cause interferences during quantitative analysis of PBDFs when using HRGC/HRMS. The objective of this study was to develop a method of perfect separation of PBDDs/DFs from PBDEs and their congener-specific determination using HRGC/HRMS but also to optimize quantification of BDE 209 in environmental samples.

  6. Pyrrolizidine alkaloids in honey: comparison of analytical methods

    NARCIS (Netherlands)

    Kempf, M.; Wittig, M.; Reinhard, A.; Ohe, von der K.; Blacquière, T.; Raezke, K.P.; Michel, R.; Schreier, P.; Beuerle, T.

    2011-01-01

    Pyrrolizidine alkaloids (PAs) are a structurally diverse group of toxicologically relevant secondary plant metabolites. Currently, two analytical methods are used to determine PA content in honey. To achieve reasonably high sensitivity and selectivity, mass spectrometry detection is demanded. One

  7. Long-Term Prediction of Satellite Orbit Using Analytical Method

    Directory of Open Access Journals (Sweden)

    Jae-Cheol Yoon

    1997-12-01

    Full Text Available A long-term prediction algorithm of geostationary orbit was developed using the analytical method. The perturbation force models include geopotential upto fifth order and degree and luni-solar gravitation, and solar radiation pressure. All of the perturbation effects were analyzed by secular variations, short-period variations, and long-period variations for equinoctial elements such as the semi-major axis, eccentricity vector, inclination vector, and mean longitude of the satellite. Result of the analytical orbit propagator was compared with that of the cowell orbit propagator for the KOREASAT. The comparison indicated that the analytical solution could predict the semi-major axis with an accuarcy of better than ~35meters over a period of 3 month.

  8. Feasibility study for automating the analytical laboratories of the Chemistry Branch, National Enforcement Investigation Center, Environmental Protection Agency

    International Nuclear Information System (INIS)

    Morris, W.F.; Fisher, E.R.; Barton, G.W. Jr.

    1978-01-01

    The feasibility of automating the analytical laboratories of the Chemistry Branch of the National Enforcement Investigation Center, Environmental Protection Agency, Denver, Colorado, is explored. The goals of the chemistry laboratory are defined, and instrumental methods and other tasks to be automated are described. Five optional automation systems are proposed to meet these goals and the options are evaluated in terms of cost effectiveness and other specified criteria. The instruments to be automated include (1) a Perkin-Elmer AA spectrophotometer 403, (2) Perkin-Elmer AA spectrophotometer 306, (3) Technicon AutoAnalyzer II, (4) Mettler electronic balance, and a (5) Jarrell-Ash ICP emission spectrometer

  9. Environmental risk assessment system for phosphogypsum tailing dams.

    Science.gov (United States)

    Sun, Xin; Ning, Ping; Tang, Xiaolong; Yi, Honghong; Li, Kai; Zhou, Lianbi; Xu, Xianmang

    2013-01-01

    This paper may be of particular interest to the readers as it provides a new environmental risk assessment system for phosphogypsum tailing dams. In this paper, we studied the phosphogypsum tailing dams which include characteristics of the pollution source, environmental risk characteristics and evaluation requirements to identify the applicable environmental risk assessment methods. Two analytical methods, that is, the analytic hierarchy process (AHP) and fuzzy logic, were used to handle the complexity of the environmental and nonquantitative data. Using our assessment method, different risk factors can be ranked according to their contributions to the environmental risk, thereby allowing the calculation of their relative priorities during decision making. Thus, environmental decision-makers can use this approach to develop alternative management strategies for proposed, ongoing, and completed PG tailing dams.

  10. Status of immunoassay as an analytical tool in environmental investigations

    International Nuclear Information System (INIS)

    Van Emon, J.M.

    2000-01-01

    Immunoassay methods were initially applied in clinical situations where their sensitivity and selectivity were utilized for diagnostic purposes. In the 1970s, pesticide chemists realized the potential benefits of immunoassay methods for compounds difficult to analyze by gas chromatography. This transition of the technology has extended to the analysis of soil, water, food and other matrices of environmental and human exposure significance particularly for compounds difficult to analyze by chromatographic methods. The utility of radioimmunoassays and enzyme immunoassays for environmental investigations was recognized in the 1980s by the U.S. Environmental Protection Agency (U.S. EPA) with the initiation of an immunoassay development programme. The U.S. Department of Agriculture (USDA) and the U.S. Food and Drug Administration (PDA) have investigated immunoassays for the detection of residues in food both from an inspection and a contamination prevention perspective. Environmental immunoassays are providing rapid screening information as well as quantitative information to fulfill rigorous data quality objectives for monitoring programmes

  11. An analytical-numerical comprehensive method for optimizing the fringing magnetic field

    International Nuclear Information System (INIS)

    Xiao Meiqin; Mao Naifeng

    1991-01-01

    The criterion of optimizing the fringing magnetic field is discussed, and an analytical-numerical comprehensive method for realizing the optimization is introduced. The method mentioned above consists of two parts, the analytical part calculates the field of the shims, which corrects the fringing magnetic field by using uniform magnetizing method; the numerical part fulfils the whole calculation of the field distribution by solving the equation of magnetic vector potential A within the region covered by arbitrary triangular meshes with the aid of finite difference method and successive over relaxation method. On the basis of the method, the optimization of the fringing magnetic field for a large-scale electromagnetic isotope separator is finished

  12. Comparison of soil sampling and analytical methods for asbestos at the Sumas Mountain Asbestos Site-Working towards a toolbox for better assessment.

    Science.gov (United States)

    Wroble, Julie; Frederick, Timothy; Frame, Alicia; Vallero, Daniel

    2017-01-01

    Established soil sampling methods for asbestos are inadequate to support risk assessment and risk-based decision making at Superfund sites due to difficulties in detecting asbestos at low concentrations and difficulty in extrapolating soil concentrations to air concentrations. Environmental Protection Agency (EPA)'s Office of Land and Emergency Management (OLEM) currently recommends the rigorous process of Activity Based Sampling (ABS) to characterize site exposures. The purpose of this study was to compare three soil analytical methods and two soil sampling methods to determine whether one method, or combination of methods, would yield more reliable soil asbestos data than other methods. Samples were collected using both traditional discrete ("grab") samples and incremental sampling methodology (ISM). Analyses were conducted using polarized light microscopy (PLM), transmission electron microscopy (TEM) methods or a combination of these two methods. Data show that the fluidized bed asbestos segregator (FBAS) followed by TEM analysis could detect asbestos at locations that were not detected using other analytical methods; however, this method exhibited high relative standard deviations, indicating the results may be more variable than other soil asbestos methods. The comparison of samples collected using ISM versus discrete techniques for asbestos resulted in no clear conclusions regarding preferred sampling method. However, analytical results for metals clearly showed that measured concentrations in ISM samples were less variable than discrete samples.

  13. FORECASTING PILE SETTLEMENT ON CLAYSTONE USING NUMERICAL AND ANALYTICAL METHODS

    Directory of Open Access Journals (Sweden)

    Ponomarev Andrey Budimirovich

    2016-06-01

    Full Text Available In the article the problem of designing pile foundations on claystones is reviewed. The purpose of this paper is comparative analysis of the analytical and numerical methods for forecasting the settlement of piles on claystones. The following tasks were solved during the study: 1 The existing researches of pile settlement are analyzed; 2 The characteristics of experimental studies and the parameters for numerical modeling are presented, methods of field research of single piles’ operation are described; 3 Calculation of single pile settlement is performed using numerical methods in the software package Plaxis 2D and analytical method according to the requirements SP 24.13330.2011; 4 Experimental data is compared with the results of analytical and numerical calculations; 5 Basing on these results recommendations for forecasting pile settlement on claystone are presented. Much attention is paid to the calculation of pile settlement considering the impacted areas in ground space beside pile and the comparison with the results of field experiments. Basing on the obtained results, for the prediction of settlement of single pile on claystone the authors recommend using the analytical method considered in SP 24.13330.2011 with account for the impacted areas in ground space beside driven pile. In the case of forecasting the settlement of single pile on claystone by numerical methods in Plaxis 2D the authors recommend using the Hardening Soil model considering the impacted areas in ground space beside the driven pile. The analyses of the results and calculations are presented for examination and verification; therefore it is necessary to continue the research work of deep foundation at another experimental sites to improve the reliability of the calculation of pile foundation settlement. The work is of great interest for geotechnical engineers engaged in research, design and construction of pile foundations.

  14. Modern methods in analytical acoustics lecture notes

    CERN Document Server

    Crighton, D G; Williams, J E Ffowcs; Heckl, M; Leppington, F G

    1992-01-01

    Modern Methods in Analytical Acoustics considers topics fundamental to the understanding of noise, vibration and fluid mechanisms. The series of lectures on which this material is based began by some twenty five years ago and has been developed and expanded ever since. Acknowledged experts in the field have given this course many times in Europe and the USA. Although the scope of the course has widened considerably, the primary aim of teaching analytical techniques of acoustics alongside specific areas of wave motion and unsteady fluid mechanisms remains. The distinguished authors of this volume are drawn from Departments of Acoustics, Engineering of Applied Mathematics in Berlin, Cambridge and London. Their intention is to reach a wider audience of all those concerned with acoustic analysis than has been able to attend the course.

  15. Radioimmunoassay. A revolution in the analytic procedure

    Energy Technology Data Exchange (ETDEWEB)

    Strecker, H; Eckert, H G [Farbwerke Hoechst A.G., Frankfurt am Main (Germany, F.R.). Radiochemisches Lab.

    1978-04-01

    Radioimmunoassay is an analytic method which combines the sensitivity of radioactive measurement and the specificity of the antigen-antibody reaction Substances down to a concentration of some picograms per ml serum (or biological material) can be measured in the presence of a millionfold excess of otherwise interfering substances. The method is easy to carry out (test tube chemistry). The main field of application at the moment is in endocrinology; further possibilities of application are in pharmaceutical research, environmental protection, forensic medicine, and for general analytic purposes. Radioactive sources are used only in vitro in the nanocurie range, i.e. radiation exposure is negligible.

  16. OPTIMAL METHOD FOR PREPARATION OF SILICATE ROCK SAMPLES FOR ANALYTICAL PURPOSES

    Directory of Open Access Journals (Sweden)

    Maja Vrkljan

    2004-12-01

    Full Text Available The purpose of this study was to determine an optimal dissolution method for silicate rock samples for further analytical purposes. Analytical FAAS method of determining cobalt, chromium, copper, nickel, lead and zinc content in gabbro sample and geochemical standard AGV-1 has been applied for verification. Dissolution in mixtures of various inorganic acids has been tested, as well as Na2CO3 fusion technique. The results obtained by different methods have been compared and dissolution in the mixture of HNO3 + HF has been recommended as optimal.

  17. Hydrophilic and amphiphilic water pollutants: using advanced analytical methods for classic and emerging contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Giger, Walter [GRC, Giger Research Consulting, Zurich (Switzerland); Eawag, Swiss Federal Institute of Aquatic Science and Technology, Duebendorf (Switzerland)

    2009-01-15

    Organic pollutants are a highly relevant topic in environmental science and technology. This article briefly reviews historic developments, and then focuses on the current state of the art and future perspectives on the qualitative and quantitative trace determination of polar organic contaminants, which are of particular concern in municipal and industrial wastewater effluents, ambient surface waters, run-off waters, atmospheric waters, groundwaters and drinking waters. The pivotal role of advanced analytical methods is emphasized and an overview of some contaminant classes is presented. Some examples of polar water pollutants, which are discussed in a bit more detail here, are chosen from projects tackled by the research group led by the author of this article. (orig.)

  18. BIOSENSORS FOR ENVIRONMENTAL MONITORING: A REGULATORY PERSPECTIVE

    Science.gov (United States)

    Biosensors show the potential to complement laboratory-based analytical methods for environmental applications. Although biosensors for potential environmental-monitoring applications have been reported for a wide range of environmental pollutants, from a regulatory perspective, ...

  19. Analytic Methods Used in Quality Control in a Compounding Pharmacy.

    Science.gov (United States)

    Allen, Loyd V

    2017-01-01

    Analytical testing will no doubt become a more important part of pharmaceutical compounding as the public and regulatory agencies demand increasing documentation of the quality of compounded preparations. Compounding pharmacists must decide what types of testing and what amount of testing to include in their quality-control programs, and whether testing should be done in-house or outsourced. Like pharmaceutical compounding, analytical testing should be performed only by those who are appropriately trained and qualified. This article discusses the analytical methods that are used in quality control in a compounding pharmacy. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  20. Analytical maximum-likelihood method to detect patterns in real networks

    International Nuclear Information System (INIS)

    Squartini, Tiziano; Garlaschelli, Diego

    2011-01-01

    In order to detect patterns in real networks, randomized graph ensembles that preserve only part of the topology of an observed network are systematically used as fundamental null models. However, the generation of them is still problematic. Existing approaches are either computationally demanding and beyond analytic control or analytically accessible but highly approximate. Here, we propose a solution to this long-standing problem by introducing a fast method that allows one to obtain expectation values and standard deviations of any topological property analytically, for any binary, weighted, directed or undirected network. Remarkably, the time required to obtain the expectation value of any property analytically across the entire graph ensemble is as short as that required to compute the same property using the adjacency matrix of the single original network. Our method reveals that the null behavior of various correlation properties is different from what was believed previously, and is highly sensitive to the particular network considered. Moreover, our approach shows that important structural properties (such as the modularity used in community detection problems) are currently based on incorrect expressions, and provides the exact quantities that should replace them.

  1. Metal speciation: survey of environmental methods of analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mach, M.H.; Nott, B.; Scott, J.W.; Maddalone, R.F.; Whiddon, N.T. [TRW, Redondo Beach, CA (United States). Chemistry Technology Dept.

    1996-07-01

    As part of a recent task under the EPRI Analytical Methods Qualification Program (RP 1851), TRW has surveyed the methods available for monitoring metal species in typical utility aqueous discharge streams. Methods for determining the individual species of these metals can become important in a regulatory sense as the EPA transitions to assessment of environmental risk based on bioavailability. For example, EPA considers methyl mercury and Cr(VI) much more toxic to the aquatic environment than inorganic mercury or Cr(III). The species of a given element can also differ in their transport and bioaccumulation. Methods for speciation generally include a selective separation step followed by standard metals analysis. Speciation, therefore, is mainly derived from the separation step and not from the method of final quantisation. Examples of separation/analysis include: selective extraction followed by graphite furnace atomic absorption or ICP-MS; separation by GC followed by metals detection; chelation and/or direct separation by LC followed by UV measurement or metals detection; and ion chromatography with conductivity, UV, or metals detection. There are a number of sampling issues associated with metal species such as stabilization (maintaining oxidation state), absorption, and filtration that need to be addressed in order to obtain and maintain a representative sample for analysis. 45 refs., 1 tab.

  2. Application of capability indices and control charts in the analytical method control strategy.

    Science.gov (United States)

    Oliva, Alexis; Llabres Martinez, Matías

    2017-08-01

    In this study, we assessed the usefulness of control charts in combination with the process capability indices, C pm and C pk , in the control strategy of an analytical method. The traditional X-chart and moving range chart were used to monitor the analytical method over a 2-year period. The results confirmed that the analytical method is in-control and stable. Different criteria were used to establish the specifications limits (i.e. analyst requirements) for fixed method performance (i.e. method requirements). If the specification limits and control limits are equal in breadth, the method can be considered "capable" (C pm  = 1), but it does not satisfy the minimum method capability requirements proposed by Pearn and Shu (2003). Similar results were obtained using the C pk index. The method capability was also assessed as a function of method performance for fixed analyst requirements. The results indicate that the method does not meet the requirements of the analytical target approach. A real-example data of a SEC with light-scattering detection method was used as a model whereas previously published data were used to illustrate the applicability of the proposed approach. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Application of Synchrotron Radiation-based Methods for Environmental Biogeochemistry: Introduction to the Special Section

    Energy Technology Data Exchange (ETDEWEB)

    Hettiarachchi, Ganga M.; Donner, Erica; Doelsch, Emmanuel

    2017-01-01

    To understand the biogeochemistry of nutrients and contaminants in environmental media, their speciation and behavior under different conditions and at multiple scales must be determined. Synchrotron radiation-based X-ray techniques allow scientists to elucidate the underlying mechanisms responsible for nutrient and contaminant mobility, bioavailability, and behavior. The continuous improvement of synchrotron light sources and X-ray beamlines around the world has led to a profound transformation in the field of environmental biogeochemistry and, subsequently, to significant scientific breakthroughs. Following this introductory paper, this special collection includes 10 papers that either present targeted reviews of recent advancements in spectroscopic methods that are applicable to environmental biogeochemistry or describe original research studies conducted on complex environmental samples that have been significantly enhanced by incorporating synchrotron radiation-based X-ray technique(s). We believe that the current focus on improving the speciation of ultra-dilute elements in environmental media through the ongoing optimization of synchrotron technologies (e.g., brighter light sources, improved monochromators, more efficient detectors) will help to significantly push back the frontiers of environmental biogeochemistry research. As many of the relevant techniques produce extremely large datasets, we also identify ongoing improvements in data processing and analysis (e.g., software improvements and harmonization of analytical methods) as a significant requirement for environmental biogeochemists to maximize the information that can be gained using these powerful tools.

  4. Intercalibration of analytical methods on marine environmental samples. Results of MEDPOL-II exercise for the intercalibration of chlorinated hydrocarbon measurements on mussel homogenate (MA-M-2/OC)

    International Nuclear Information System (INIS)

    1986-10-01

    Mussels have been considered as good indicators of chlorinated hydrocarbon pollution of the marine environment and this led to the development of mussel watch programmes in many countries in the late seventies. These intercalibration exercises were arranged in order to increase the quality of analytical capabilities of environmental laboratories. The samples MA-M-2/0C of Mediterranean mussels with chlorinated hydrocarbon content were checked by 27 laboratories. It was judged highly suitable for these laboratories to have at their disposal a reference material made of mussel tissue with robust estimations of the true values with respect to several chlorinated hydrocarbons. Such a material would allow chemists to check the validity of new analytical procedures

  5. The Emergence of the Analytical Method

    DEFF Research Database (Denmark)

    Plum, Maja

    2012-01-01

    accountability, visibility and documentation. It is argued that pedagogy is generated as a sequential and unit-specified way of working on the production of ‘the learning child’, forming a time- and material-optimising approach. Hereby, the nursery teacher, as a daily scientific researcher, comes to serve...... the nation by an ongoing observational intervention, producing the learning foundation for the entrepreneurial citizen, and thus the nation as a knowledge society in a globalised world. This is what this article terms the emergence of the analytical method....

  6. Evaluating water management strategies in watersheds by new hybrid Fuzzy Analytical Network Process (FANP) methods

    Science.gov (United States)

    RazaviToosi, S. L.; Samani, J. M. V.

    2016-03-01

    Watersheds are considered as hydrological units. Their other important aspects such as economic, social and environmental functions play crucial roles in sustainable development. The objective of this work is to develop methodologies to prioritize watersheds by considering different development strategies in environmental, social and economic sectors. This ranking could play a significant role in management to assign the most critical watersheds where by employing water management strategies, best condition changes are expected to be accomplished. Due to complex relations among different criteria, two new hybrid fuzzy ANP (Analytical Network Process) algorithms, fuzzy TOPSIS (Technique for Order Preference by Similarity to Ideal Solution) and fuzzy max-min set methods are used to provide more flexible and accurate decision model. Five watersheds in Iran named Oroomeyeh, Atrak, Sefidrood, Namak and Zayandehrood are considered as alternatives. Based on long term development goals, 38 water management strategies are defined as subcriteria in 10 clusters. The main advantage of the proposed methods is its ability to overcome uncertainty. This task is accomplished by using fuzzy numbers in all steps of the algorithms. To validate the proposed method, the final results were compared with those obtained from the ANP algorithm and the Spearman rank correlation coefficient is applied to find the similarity in the different ranking methods. Finally, the sensitivity analysis was conducted to investigate the influence of cluster weights on the final ranking.

  7. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for

  8. Green Chemistry Metrics with Special Reference to Green Analytical Chemistry

    Directory of Open Access Journals (Sweden)

    Marek Tobiszewski

    2015-06-01

    Full Text Available The concept of green chemistry is widely recognized in chemical laboratories. To properly measure an environmental impact of chemical processes, dedicated assessment tools are required. This paper summarizes the current state of knowledge in the field of development of green chemistry and green analytical chemistry metrics. The diverse methods used for evaluation of the greenness of organic synthesis, such as eco-footprint, E-Factor, EATOS, and Eco-Scale are described. Both the well-established and recently developed green analytical chemistry metrics, including NEMI labeling and analytical Eco-scale, are presented. Additionally, this paper focuses on the possibility of the use of multivariate statistics in evaluation of environmental impact of analytical procedures. All the above metrics are compared and discussed in terms of their advantages and disadvantages. The current needs and future perspectives in green chemistry metrics are also discussed.

  9. Green Chemistry Metrics with Special Reference to Green Analytical Chemistry.

    Science.gov (United States)

    Tobiszewski, Marek; Marć, Mariusz; Gałuszka, Agnieszka; Namieśnik, Jacek

    2015-06-12

    The concept of green chemistry is widely recognized in chemical laboratories. To properly measure an environmental impact of chemical processes, dedicated assessment tools are required. This paper summarizes the current state of knowledge in the field of development of green chemistry and green analytical chemistry metrics. The diverse methods used for evaluation of the greenness of organic synthesis, such as eco-footprint, E-Factor, EATOS, and Eco-Scale are described. Both the well-established and recently developed green analytical chemistry metrics, including NEMI labeling and analytical Eco-scale, are presented. Additionally, this paper focuses on the possibility of the use of multivariate statistics in evaluation of environmental impact of analytical procedures. All the above metrics are compared and discussed in terms of their advantages and disadvantages. The current needs and future perspectives in green chemistry metrics are also discussed.

  10. An analytical optimization method for electric propulsion orbit transfer vehicles

    International Nuclear Information System (INIS)

    Oleson, S.R.

    1993-01-01

    Due to electric propulsion's inherent propellant mass savings over chemical propulsion, electric propulsion orbit transfer vehicles (EPOTVs) are a highly efficient mode of orbit transfer. When selecting an electric propulsion device (ion, MPD, or arcjet) and propellant for a particular mission, it is preferable to use quick, analytical system optimization methods instead of time intensive numerical integration methods. It is also of interest to determine each thruster's optimal operating characteristics for a specific mission. Analytical expressions are derived which determine the optimal specific impulse (Isp) for each type of electric thruster to maximize payload fraction for a desired thrusting time. These expressions take into account the variation of thruster efficiency with specific impulse. Verification of the method is made with representative electric propulsion values on a LEO-to-GEO mission. Application of the method to specific missions is discussed

  11. A first course in ordinary differential equations analytical and numerical methods

    CERN Document Server

    Hermann, Martin

    2014-01-01

    This book presents a modern introduction to analytical and numerical techniques for solving ordinary differential equations (ODEs). Contrary to the traditional format—the theorem-and-proof format—the book is focusing on analytical and numerical methods. The book supplies a variety of problems and examples, ranging from the elementary to the advanced level, to introduce and study the mathematics of ODEs. The analytical part of the book deals with solution techniques for scalar first-order and second-order linear ODEs, and systems of linear ODEs—with a special focus on the Laplace transform, operator techniques and power series solutions. In the numerical part, theoretical and practical aspects of Runge-Kutta methods for solving initial-value problems and shooting methods for linear two-point boundary-value problems are considered. The book is intended as a primary text for courses on the theory of ODEs and numerical treatment of ODEs for advanced undergraduate and early graduate students. It is assumed t...

  12. Molecularly imprinted polymers--potential and challenges in analytical chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Mahony, J.O. [Dublin City University, School of Chemical Sciences, Glasnevin, Dublin 9 (Ireland); Nolan, K. [Dublin City University, School of Chemical Sciences, Glasnevin, Dublin 9 (Ireland); Smyth, M.R. [Dublin City University, School of Chemical Sciences, Glasnevin, Dublin 9 (Ireland); Mizaikoff, B. [Georgia Institute of Technology, School of Chemistry and Biochemistry, 770 State Street, Boggs Building, Atlanta, GA 30332-0400 (United States)]. E-mail: boris.mizaikoff@chemistry.gatech.edu

    2005-04-04

    Among the variety of biomimetic recognition schemes utilizing supramolecular approaches molecularly imprinted polymers (MIPs) have proven their potential as synthetic receptors in numerous applications ranging from liquid chromatography to assays and sensor technology. Their inherent advantages compared to biochemical/biological recognition systems include robustness, storage endurance and lower costs. However, until recently only few contributions throughout the relevant literature describe quantitative analytical applications of MIPs for practically relevant analyte molecules and real-world samples. Increased motivation to thoroughly evaluate the true potential of MIP technology is clearly attributed to the demands of modern analytical chemistry, which include enhanced sensitivity, selectivity and applicability of molecular recognition building blocks at decreasing costs. In particular, the areas of environmental monitoring, food and beverage analysis and industrial process surveillance require analytical tools capable of discriminating chemicals with high molecular specificity considering increasing numbers of complex environmental contaminants, pollution of raw products and rigorous quality control requested by legislation and consumer protection. Furthermore, efficient product improvement and development of new products requires precise qualitative and quantitative analytical methods. Finally, environmental, food and process safety control issues favor the application of on-line in situ analytical methods with high molecular selectivity. While biorecognition schemes frequently suffer from degrading bioactivity and long-term stability when applied in real-world sample environments, MIPs serving as synthetic antibodies have successfully been applied as stationary phase separation matrix (e.g. HPLC and SPE), recognition component in bioassays (e.g. ELISA) or biomimetic recognition layer in chemical sensor systems. Examples such as MIP-based selective analysis of

  13. Molecularly imprinted polymers--potential and challenges in analytical chemistry

    International Nuclear Information System (INIS)

    Mahony, J.O.; Nolan, K.; Smyth, M.R.; Mizaikoff, B.

    2005-01-01

    Among the variety of biomimetic recognition schemes utilizing supramolecular approaches molecularly imprinted polymers (MIPs) have proven their potential as synthetic receptors in numerous applications ranging from liquid chromatography to assays and sensor technology. Their inherent advantages compared to biochemical/biological recognition systems include robustness, storage endurance and lower costs. However, until recently only few contributions throughout the relevant literature describe quantitative analytical applications of MIPs for practically relevant analyte molecules and real-world samples. Increased motivation to thoroughly evaluate the true potential of MIP technology is clearly attributed to the demands of modern analytical chemistry, which include enhanced sensitivity, selectivity and applicability of molecular recognition building blocks at decreasing costs. In particular, the areas of environmental monitoring, food and beverage analysis and industrial process surveillance require analytical tools capable of discriminating chemicals with high molecular specificity considering increasing numbers of complex environmental contaminants, pollution of raw products and rigorous quality control requested by legislation and consumer protection. Furthermore, efficient product improvement and development of new products requires precise qualitative and quantitative analytical methods. Finally, environmental, food and process safety control issues favor the application of on-line in situ analytical methods with high molecular selectivity. While biorecognition schemes frequently suffer from degrading bioactivity and long-term stability when applied in real-world sample environments, MIPs serving as synthetic antibodies have successfully been applied as stationary phase separation matrix (e.g. HPLC and SPE), recognition component in bioassays (e.g. ELISA) or biomimetic recognition layer in chemical sensor systems. Examples such as MIP-based selective analysis of

  14. Use of scientometrics to assess nuclear and other analytical methods

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1986-01-01

    Scientometrics involves the use of quantitative methods to investigate science viewed as an information process. Scientometric studies can be useful in ascertaining which methods have been most employed for various analytical determinations as well as for predicting which methods will continue to be used in the immediate future and which appear to be losing favor with the analytical community. Published papers in the technical literature are the primary source materials for scientometric studies; statistical methods and computer techniques are the tools. Recent studies have included growth and trends in prompt nuclear analysis impact of research published in a technical journal, and institutional and national representation, speakers and topics at several IAEA conferences, at modern trends in activation analysis conferences, and at other non-nuclear oriented conferences. Attempts have also been made to predict future growth of various topics and techniques. 13 refs., 4 figs., 17 tabs

  15. Use of scientometrics to assess nuclear and other analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Lyon, W.S.

    1986-01-01

    Scientometrics involves the use of quantitative methods to investigate science viewed as an information process. Scientometric studies can be useful in ascertaining which methods have been most employed for various analytical determinations as well as for predicting which methods will continue to be used in the immediate future and which appear to be losing favor with the analytical community. Published papers in the technical literature are the primary source materials for scientometric studies; statistical methods and computer techniques are the tools. Recent studies have included growth and trends in prompt nuclear analysis impact of research published in a technical journal, and institutional and national representation, speakers and topics at several IAEA conferences, at modern trends in activation analysis conferences, and at other non-nuclear oriented conferences. Attempts have also been made to predict future growth of various topics and techniques. 13 refs., 4 figs., 17 tabs.

  16. Prediction of polymer flooding performance using an analytical method

    International Nuclear Information System (INIS)

    Tan Czek Hoong; Mariyamni Awang; Foo Kok Wai

    2001-01-01

    The study investigated the applicability of an analytical method developed by El-Khatib in polymer flooding. Results from a simulator UTCHEM and experiments were compared with the El-Khatib prediction method. In general, by assuming a constant viscosity polymer injection, the method gave much higher recovery values than the simulation runs and the experiments. A modification of the method gave better correlation, albeit only oil production. Investigation is continuing on modifying the method so that a better overall fit can be obtained for polymer flooding. (Author)

  17. Groundwater Seepage Estimation into Amirkabir Tunnel Using Analytical Methods and DEM and SGR Method

    OpenAIRE

    Hadi Farhadian; Homayoon Katibeh

    2015-01-01

    In this paper, groundwater seepage into Amirkabir tunnel has been estimated using analytical and numerical methods for 14 different sections of the tunnel. Site Groundwater Rating (SGR) method also has been performed for qualitative and quantitative classification of the tunnel sections. The obtained results of above mentioned methods were compared together. The study shows reasonable accordance with results of the all methods unless for two sections of tunnel. In these t...

  18. Applying the Analytic Hierarchy Process to Oil Sands Environmental Compliance Risk Management

    Science.gov (United States)

    Roux, Izak Johannes, III

    Oil companies in Alberta, Canada, invested $32 billion on new oil sands projects in 2013. Despite the size of this investment, there is a demonstrable deficiency in the uniformity and understanding of environmental legislation requirements that manifest into increased project compliance risks. This descriptive study developed 2 prioritized lists of environmental regulatory compliance risks and mitigation strategies and used multi-criteria decision theory for its theoretical framework. Information from compiled lists of environmental compliance risks and mitigation strategies was used to generate a specialized pairwise survey, which was piloted by 5 subject matter experts (SMEs). The survey was validated by a sample of 16 SMEs, after which the Analytic Hierarchy Process (AHP) was used to rank a total of 33 compliance risks and 12 mitigation strategy criteria. A key finding was that the AHP is a suitable tool for ranking of compliance risks and mitigation strategies. Several working hypotheses were also tested regarding how SMEs prioritized 1 compliance risk or mitigation strategy compared to another. The AHP showed that regulatory compliance, company reputation, environmental compliance, and economics ranked the highest and that a multi criteria mitigation strategy for environmental compliance ranked the highest. The study results will inform Alberta oil sands industry leaders about the ranking and utility of specific compliance risks and mitigations strategies, enabling them to focus on actions that will generate legislative and public trust. Oil sands leaders implementing a risk management program using the risks and mitigation strategies identified in this study will contribute to environmental conservation, economic growth, and positive social change.

  19. Environmental radiation monitoring

    International Nuclear Information System (INIS)

    Watanabe, Isao

    2011-01-01

    The samples, pretreatment method, and measurement methods of 'Environmental radioactivity level by prefecture' of Ministry of Education, Culture, Sports, Science and Education (MEXT) is explained. It consists of 1), 'Environmental radioactivity level by prefecture' in normal period, 2) 'Strengthening of Monitoring of Environmental Radioactivity Level by Prefecture' of MEXT at emergency 3) strengthening of monitoring by Fukushima Daiichi nuclear accident, 4) radiation monitoring around the nuclear facility, 5) strengthening of monitoring by MEXT, and 6) quality of monitoring. The survey item and samples etc., of 'Environmental radioactivity level by prefecture', monitoring post, NaI (Tl) scintillation survey meter, sampling and pretreatment methods for radionuclide analysis in normal period, an example of germanium semiconductor detector, gamma ray spectrum of spaghetti from Italy by germanium semiconductor detector, flow chart of radionuclide analysis of fallout in normal period and emergency by germanium semiconductor detector, example of analytical method of radioactive strontium ( ion exchange method), outline of plutonium analytical method for emergency, sampling and pretreatment methods of radionuclides for strengthening, monitoring result around Fukushima Daiichi nuclear plant from June 23 to 24, 2011, change of air dose rate of monitoring post in Mito city from March 14 to 26, 2011, concentration of I-131 and Cs-137 in fallout in Hitachinaka city from March 19 to April 30, 2011, and change of concentration of I-131, Cs-134 and Cs-137 in tap water of Iitate village from March 20 to April 30, 2011, are illustrated. (S.Y.)

  20. Waste Tank Organic Safety Program: Analytical methods development. Progress report, FY 1994

    International Nuclear Information System (INIS)

    Campbell, J.A.; Clauss, S.A.; Grant, K.E.

    1994-09-01

    The objectives of this task are to develop and document extraction and analysis methods for organics in waste tanks, and to extend these methods to the analysis of actual core samples to support the Waste Tank organic Safety Program. This report documents progress at Pacific Northwest Laboratory (a) during FY 1994 on methods development, the analysis of waste from Tank 241-C-103 (Tank C-103) and T-111, and the transfer of documented, developed analytical methods to personnel in the Analytical Chemistry Laboratory (ACL) and 222-S laboratory. This report is intended as an annual report, not a completed work

  1. Analytical method development for the determination of emerging contaminants in water using supercritical-fluid chromatography coupled with diode-array detection.

    Science.gov (United States)

    Del Carmen Salvatierra-Stamp, Vilma; Ceballos-Magaña, Silvia G; Gonzalez, Jorge; Ibarra-Galván, Valentin; Muñiz-Valencia, Roberto

    2015-05-01

    An analytical method using supercritical-fluid chromatography coupled with diode-array detection for the determination of seven emerging contaminants-two pharmaceuticals (carbamazepine and glyburide), three endocrine disruptors (17α-ethinyl estradiol, bisphenol A, and 17β-estradiol), one bactericide (triclosan), and one pesticide (diuron)-was developed and validated. These contaminants were chosen because of their frequency of use and their toxic effects on both humans and the environment. The optimized chromatographic separation on a Viridis BEH 2-EP column achieved baseline resolution for all compounds in less than 10 min. This separation was applied to environmental water samples after sample preparation. The optimized sample treatment involved a preconcentration step by means of solid-phase extraction using C18-OH cartridges. The proposed method was validated, finding recoveries higher than 94 % and limits of detection and limits of quantification in the range of 0.10-1.59 μg L(-1) and 0.31-4.83 μg L(-1), respectively. Method validation established the proposed method to be selective, linear, accurate, and precise. Finally, the method was successfully applied to environmental water samples.

  2. Tank 48H Waste Composition and Results of Investigation of Analytical Methods

    Energy Technology Data Exchange (ETDEWEB)

    Walker , D.D. [Westinghouse Savannah River Company, AIKEN, SC (United States)

    1997-04-02

    This report serves two purposes. First, it documents the analytical results of Tank 48H samples taken between April and August 1996. Second, it describes investigations of the precision of the sampling and analytical methods used on the Tank 48H samples.

  3. An analytical method of estimating Value-at-Risk on the Belgrade Stock Exchange

    Directory of Open Access Journals (Sweden)

    Obadović Milica D.

    2009-01-01

    Full Text Available This paper presents market risk evaluation for a portfolio consisting of shares that are continuously traded on the Belgrade Stock Exchange, by applying the Value-at-Risk model - the analytical method. It describes the manner of analytical method application and compares the results obtained by implementing this method at different confidence levels. Method verification was carried out on the basis of the failure rate that demonstrated the confidence level for which this method was acceptable in view of the given conditions.

  4. An Analytical Method of Auxiliary Sources Solution for Plane Wave Scattering by Impedance Cylinders

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2004-01-01

    Analytical Method of Auxiliary Sources solutions for plane wave scattering by circular impedance cylinders are derived by transformation of the exact eigenfunction series solutions employing the Hankel function wave transformation. The analytical Method of Auxiliary Sources solution thus obtained...

  5. Continuous Analytical Performances Monitoring at the On-Site Laboratory through Proficiency, Inter-Laboratory Testing and Inter-Comparison Analytical Methods

    International Nuclear Information System (INIS)

    Duhamel, G.; Decaillon, J.-G.; Dashdondog, S.; Kim, C.-K.; Toervenyi, A.; Hara, S.; Kato, S.; Kawaguchi, T.; Matsuzawa, K.

    2015-01-01

    Since 2008, as one measure to strengthen its quality management system, the On-Site Laboratory for nuclear safeguards at the Rokkasho Reprocessing Plant, has increased its participation in domestic and international proficiency and inter-laboratory testing for the purpose of determining analytical method accuracy, precision and robustness but also to support method development and improvement. This paper provides a description of the testing and its scheduling. It presents the way the testing was optimized to cover most of the analytical methods at the OSL. The paper presents the methodology used for the evaluation of the obtained results based on Analysis of variance (ANOVA). Results are discussed with respect to random, systematic and long term systematic error. (author)

  6. Analytical Energy Gradients for Excited-State Coupled-Cluster Methods

    Science.gov (United States)

    Wladyslawski, Mark; Nooijen, Marcel

    The equation-of-motion coupled-cluster (EOM-CC) and similarity transformed equation-of-motion coupled-cluster (STEOM-CC) methods have been firmly established as accurate and routinely applicable extensions of single-reference coupled-cluster theory to describe electronically excited states. An overview of these methods is provided, with emphasis on the many-body similarity transform concept that is the key to a rationalization of their accuracy. The main topic of the paper is the derivation of analytical energy gradients for such non-variational electronic structure approaches, with an ultimate focus on obtaining their detailed algebraic working equations. A general theoretical framework using Lagrange's method of undetermined multipliers is presented, and the method is applied to formulate the EOM-CC and STEOM-CC gradients in abstract operator terms, following the previous work in [P.G. Szalay, Int. J. Quantum Chem. 55 (1995) 151] and [S.R. Gwaltney, R.J. Bartlett, M. Nooijen, J. Chem. Phys. 111 (1999) 58]. Moreover, the systematics of the Lagrange multiplier approach is suitable for automation by computer, enabling the derivation of the detailed derivative equations through a standardized and direct procedure. To this end, we have developed the SMART (Symbolic Manipulation and Regrouping of Tensors) package of automated symbolic algebra routines, written in the Mathematica programming language. The SMART toolkit provides the means to expand, differentiate, and simplify equations by manipulation of the detailed algebraic tensor expressions directly. The Lagrangian multiplier formulation establishes a uniform strategy to perform the automated derivation in a standardized manner: A Lagrange multiplier functional is constructed from the explicit algebraic equations that define the energy in the electronic method; the energy functional is then made fully variational with respect to all of its parameters, and the symbolic differentiations directly yield the explicit

  7. Analytical chemistry methods for boron carbide absorber material. [Standard

    Energy Technology Data Exchange (ETDEWEB)

    DELVIN WL

    1977-07-01

    This standard provides analytical chemistry methods for the analysis of boron carbide powder and pellets for the following: total C and B, B isotopic composition, soluble C and B, fluoride, chloride, metallic impurities, gas content, water, nitrogen, and oxygen. (DLC)

  8. An interactive website for analytical method comparison and bias estimation.

    Science.gov (United States)

    Bahar, Burak; Tuncel, Ayse F; Holmes, Earle W; Holmes, Daniel T

    2017-12-01

    Regulatory standards mandate laboratories to perform studies to ensure accuracy and reliability of their test results. Method comparison and bias estimation are important components of these studies. We developed an interactive website for evaluating the relative performance of two analytical methods using R programming language tools. The website can be accessed at https://bahar.shinyapps.io/method_compare/. The site has an easy-to-use interface that allows both copy-pasting and manual entry of data. It also allows selection of a regression model and creation of regression and difference plots. Available regression models include Ordinary Least Squares, Weighted-Ordinary Least Squares, Deming, Weighted-Deming, Passing-Bablok and Passing-Bablok for large datasets. The server processes the data and generates downloadable reports in PDF or HTML format. Our website provides clinical laboratories a practical way to assess the relative performance of two analytical methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. An analytic method for S-expansion involving resonance and reduction

    Energy Technology Data Exchange (ETDEWEB)

    Ipinza, M.C.; Penafiel, D.M. [Departamento de Fisica, Universidad de Concepcion (Chile); DISAT, Politecnico di Torino (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Torino (Italy); Lingua, F. [DISAT, Politecnico di Torino (Italy); Ravera, L. [DISAT, Politecnico di Torino (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Torino (Italy)

    2016-11-15

    In this paper we describe an analytic method able to give the multiplication table(s) of the set(s) involved in an S-expansion process (with either resonance or 0{sub S}-resonant-reduction) for reaching a target Lie (super)algebra from a starting one, after having properly chosen the partitions over subspaces of the considered (super)algebras. This analytic method gives us a simple set of expressions to find the subset decomposition of the set(s) involved in the process. Then, we use the information coming from both the initial (super)algebra and the target one for reaching the multiplication table(s) of the mentioned set(s). Finally, we check associativity with an auxiliary computational algorithm, in order to understand whether the obtained set(s) can describe semigroup(s) or just abelian set(s) connecting two (super)algebras. We also give some interesting examples of application, which check and corroborate our analytic procedure and also generalize some result already presented in the literature. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Analytical method used for intermediate products in continuous distillation of furfural

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Z.L.; Jia, M.; Wang, L.J.; Deng, Y.X.

    1981-01-01

    During distillation of furfural, analysis of main components in the crude furfural condensate and intermediate products is very important. Since furfural and methylfurfural are homologous and both furfural and acetone contain a carbonyl group, components in the sample must be separated before analysis. An improved analytical method has been studied, the accuracy and precision of which would meet the requirement of industrial standards. The analytical procedure was provided as follows: to determine the furfural content with gravimetric method of barbituric acid; to determine the methanol content with dichromate method after precipitating furfural and acetone, and distilling the liquid for analysis; and to determine the methylfurfural content with bromide-bromate method, which can be used only in the sample containing higher content of methylfurfural. For the sample in low content, the gas-liquid chromatographic method can be used. 7 references.

  11. Sample preparation method for the speciation of polybrominated diphenyl ethers and their methoxylated and hydroxylated analogues in diverse environmental matrices.

    Science.gov (United States)

    Sun, Jianteng; Liu, Jiyan; Liu, Qian; Qu, Guangbo; Ruan, Ting; Jiang, Guibin

    2012-01-15

    A reliable analytical method was developed here for the simultaneous separation, identification and quantification of ten polybrominated diphenyl ethers (PBDEs), nine methoxylated PBDEs (MeO-PBDEs) and ten hydroxylated PBDEs (OH-PBDEs) in various environmental matrices, including water, soil, sediment, plant, mollusk and fish. PBDEs and MeO-PBDEs were measured by gas chromatography coupled with mass spectrometry (GC/MS) and liquid chromatography coupled with electrospray ionization (negative)-tandem quadrupole mass spectrometry (LC/ESI(-)-MS/MS) for the separation and determination of OH-PBDEs without prior derivatization. After preliminary sample cleaning using acid silica gel, water-impregnated silica column separation of PBDEs, MeO-PBDEs and OH-PBDEs was proved to be rapid, simple, and efficient. For phenolic analytes, the method detection limits (MDLs) were 3.2-11.6pg/L in water sample and 2.8-18.4pg/g dry weight in solid samples. For neutral compounds, MDLs were 48.8-150.3pg/L in water sample and 46.5-170.8pg/g dry weight in solid samples. The method was validated using six kinds of environmental samples spiked with all analytes at three concentration levels (0.3ng, 2ng and 5ng, respectively) for recovery (71-113%) and repeatability determination (4-12%RSD). Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Method of sections in analytical calculations of pneumatic tires

    Science.gov (United States)

    Tarasov, V. N.; Boyarkina, I. V.

    2018-01-01

    Analytical calculations in the pneumatic tire theory are more preferable in comparison with experimental methods. The method of section of a pneumatic tire shell allows to obtain equations of intensities of internal forces in carcass elements and bead rings. Analytical dependencies of intensity of distributed forces have been obtained in tire equator points, on side walls (poles) and pneumatic tire bead rings. Along with planes in the capacity of secant surfaces cylindrical surfaces are used for the first time together with secant planes. The tire capacity equation has been obtained using the method of section, by means of which a contact body is cut off from the tire carcass along the contact perimeter by the surface which is normal to the bearing surface. It has been established that the Laplace equation for the solution of tasks of this class of pneumatic tires contains two unknown values that requires the generation of additional equations. The developed computational schemes of pneumatic tire sections and new equations allow to accelerate the pneumatic tire structure improvement process during engineering.

  13. Validation of an analytical method for simultaneous high-precision measurements of greenhouse gas emissions from wastewater treatment plants using a gas chromatography-barrier discharge detector system.

    Science.gov (United States)

    Pascale, Raffaella; Caivano, Marianna; Buchicchio, Alessandro; Mancini, Ignazio M; Bianco, Giuliana; Caniani, Donatella

    2017-01-13

    Wastewater treatment plants (WWTPs) emit CO 2 and N 2 O, which may lead to climate change and global warming. Over the last few years, awareness of greenhouse gas (GHG) emissions from WWTPs has increased. Moreover, the development of valid, reliable, and high-throughput analytical methods for simultaneous gas analysis is an essential requirement for environmental applications. In the present study, an analytical method based on a gas chromatograph (GC) equipped with a barrier ionization discharge (BID) detector was developed for the first time. This new method simultaneously analyses CO 2 and N 2 O and has a precision, measured in terms of relative standard of variation RSD%, equal to or less than 6.6% and 5.1%, respectively. The method's detection limits are 5.3ppm v for CO 2 and 62.0ppb v for N 2 O. The method's selectivity, linearity, accuracy, repeatability, intermediate precision, limit of detection and limit of quantification were good at trace concentration levels. After validation, the method was applied to a real case of N 2 O and CO 2 emissions from a WWTP, confirming its suitability as a standard procedure for simultaneous GHG analysis in environmental samples containing CO 2 levels less than 12,000mg/L. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Approximate Analytic Solutions for the Two-Phase Stefan Problem Using the Adomian Decomposition Method

    Directory of Open Access Journals (Sweden)

    Xiao-Ying Qin

    2014-01-01

    Full Text Available An Adomian decomposition method (ADM is applied to solve a two-phase Stefan problem that describes the pure metal solidification process. In contrast to traditional analytical methods, ADM avoids complex mathematical derivations and does not require coordinate transformation for elimination of the unknown moving boundary. Based on polynomial approximations for some known and unknown boundary functions, approximate analytic solutions for the model with undetermined coefficients are obtained using ADM. Substitution of these expressions into other equations and boundary conditions of the model generates some function identities with the undetermined coefficients. By determining these coefficients, approximate analytic solutions for the model are obtained. A concrete example of the solution shows that this method can easily be implemented in MATLAB and has a fast convergence rate. This is an efficient method for finding approximate analytic solutions for the Stefan and the inverse Stefan problems.

  15. Evaluation of environmental samples containing heavy hydrocarbon components in environmental forensic investigations

    Energy Technology Data Exchange (ETDEWEB)

    Raia, J.C.; Blakley, C.R.; Fuex, A.N.; Villalanti, D.C.; Fahrenthold, P.D. [Triton Anal Corp, Houston, TX (United States)

    2004-03-01

    This article presents a procedure to evaluate and characterize environmental samples containing mixtures of hydrocarbons over a wide boiling range of materials that include fuels and other products used in commerce. The range of the method extends to the higher boiling and heavier molecular weight hydrocarbon products in the range of motor oil, bunker fuel, and heavier residue materials. The procedure uses the analytical laboratory technique of high-temperature simulated distillation along with mathematical regression of the analytical data to estimate the relative contribution of individual products in mixtures of hydrocarbons present in environmental samples. An analytical technique to determine hydrocarbon-type distributions by gas chromatography-mass spectrometry with nitric oxide ionization spectrometry evaluation is also presented. This type of analysis allows complex hydrocarbon mixtures to be classified by their chemical composition, or types of hydrocarbons that include paraffins, cycloparaffins, monoaromatics, and polycyclic aromatic hydrocarbons. Characteristic hydrocarbon patterns for example, in the relative distribution of polycyclic aromatic hydrocarbons are valuable for determining the potential origin of materials present in environmental samples. These methods provide quantitative data for hydrocarbon components in mixtures as a function of boiling range and 'hydrocarbon fingerprints' of the types of materials present. This information is valuable in assessing environmental impacts of hydrocarbons at contaminated sites and establishing the liabilities and cost allocations for responsible parties.

  16. Elasto-plastic strain analysis by a semi-analytical method

    Indian Academy of Sciences (India)

    deformation problems following a semi-analytical method, incorporating the com- ..... The set of equations in (8) are non-linear in nature, which is solved by direct ...... Here, [K] and [M] are stiffness matrix and mass matrix which are of the form ...

  17. A two-dimensional, semi-analytic expansion method for nodal calculations

    International Nuclear Information System (INIS)

    Palmtag, S.P.

    1995-08-01

    Most modern nodal methods used today are based upon the transverse integration procedure in which the multi-dimensional flux shape is integrated over the transverse directions in order to produce a set of coupled one-dimensional flux shapes. The one-dimensional flux shapes are then solved either analytically or by representing the flux shape by a finite polynomial expansion. While these methods have been verified for most light-water reactor applications, they have been found to have difficulty predicting the large thermal flux gradients near the interfaces of highly-enriched MOX fuel assemblies. A new method is presented here in which the neutron flux is represented by a non-seperable, two-dimensional, semi-analytic flux expansion. The main features of this method are (1) the leakage terms from the node are modeled explicitly and therefore, the transverse integration procedure is not used, (2) the corner point flux values for each node are directly edited from the solution method, and a corner-point interpolation is not needed in the flux reconstruction, (3) the thermal flux expansion contains hyperbolic terms representing analytic solutions to the thermal flux diffusion equation, and (4) the thermal flux expansion contains a thermal to fast flux ratio term which reduces the number of polynomial expansion functions needed to represent the thermal flux. This new nodal method has been incorporated into the computer code COLOR2G and has been used to solve a two-dimensional, two-group colorset problem containing uranium and highly-enriched MOX fuel assemblies. The results from this calculation are compared to the results found using a code based on the traditional transverse integration procedure

  18. The analytic regularization ζ function method and the cut-off method in Casimir effect

    International Nuclear Information System (INIS)

    Svaiter, N.F.; Svaiter, B.F.

    1990-01-01

    The zero point energy associated to a hermitian massless scalar field in the presence of perfectly reflecting plates in a three dimensional flat space-time is discussed. A new technique to unify two different methods - the ζ function and a variant of the cut-off method - used to obtain the so called Casimir energy is presented, and the proof of the analytic equivalence between both methods is given. (author)

  19. Development of CAD implementing the algorithm of boundary elements’ numerical analytical method

    Directory of Open Access Journals (Sweden)

    Yulia V. Korniyenko

    2015-03-01

    Full Text Available Up to recent days the algorithms for numerical-analytical boundary elements method had been implemented with programs written in MATLAB environment language. Each program had a local character, i.e. used to solve a particular problem: calculation of beam, frame, arch, etc. Constructing matrices in these programs was carried out “manually” therefore being time-consuming. The research was purposed onto a reasoned choice of programming language for new CAD development, allows to implement algorithm of numerical analytical boundary elements method and to create visualization tools for initial objects and calculation results. Research conducted shows that among wide variety of programming languages the most efficient one for CAD development, employing the numerical analytical boundary elements method algorithm, is the Java language. This language provides tools not only for development of calculating CAD part, but also to build the graphic interface for geometrical models construction and calculated results interpretation.

  20. Analytical method for reconstruction pin to pin of the nuclear power density distribution

    International Nuclear Information System (INIS)

    Pessoa, Paulo O.; Silva, Fernando C.; Martinez, Aquilino S.

    2013-01-01

    An accurate and efficient method for reconstructing pin to pin of the nuclear power density distribution, involving the analytical solution of the diffusion equation for two-dimensional neutron energy groups in homogeneous nodes, is presented. The boundary conditions used for analytic as solution are the four currents or fluxes on the surface of the node, which are obtained by Nodal Expansion Method (known as NEM) and four fluxes at the vertices of a node calculated using the finite difference method. The analytical solution found is the homogeneous distribution of neutron flux. Detailed distributions pin to pin inside a fuel assembly are estimated by the product of homogeneous flux distribution by local heterogeneous form function. Furthermore, the form functions of flux and power are used. The results obtained with this method have a good accuracy when compared with reference values. (author)

  1. Analytical method for reconstruction pin to pin of the nuclear power density distribution

    Energy Technology Data Exchange (ETDEWEB)

    Pessoa, Paulo O.; Silva, Fernando C.; Martinez, Aquilino S., E-mail: ppessoa@con.ufrj.br, E-mail: fernando@con.ufrj.br, E-mail: aquilino@imp.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    An accurate and efficient method for reconstructing pin to pin of the nuclear power density distribution, involving the analytical solution of the diffusion equation for two-dimensional neutron energy groups in homogeneous nodes, is presented. The boundary conditions used for analytic as solution are the four currents or fluxes on the surface of the node, which are obtained by Nodal Expansion Method (known as NEM) and four fluxes at the vertices of a node calculated using the finite difference method. The analytical solution found is the homogeneous distribution of neutron flux. Detailed distributions pin to pin inside a fuel assembly are estimated by the product of homogeneous flux distribution by local heterogeneous form function. Furthermore, the form functions of flux and power are used. The results obtained with this method have a good accuracy when compared with reference values. (author)

  2. Analytical methods and laboratory facility for the Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Dewberry, R.A.; Lethco, A.J.; Denard, C.D.

    1985-01-01

    This paper describes the analytical methods, instruments, and laboratory that will support vitrification of defense waste. The Defense Waste Processing Facility (DWPF) is now being constructed at Savannah River Plant (SRP). Beginning in 1989, SRP high-level defense waste will be immobilized in borosilicate glass for disposal in a federal repository. The DWPF will contain an analytical laboratory for performing process control analyses. Additional analyses will be performed for process history and process diagnostics. The DWPF analytical facility will consist of a large shielded sampling cell, three shielded analytical cells, a laboratory for instrumental analysis and chemical separations, and a counting room. Special instrumentation is being designed for use in the analytical cells, including microwave drying/dissolution apparatus, and remote pipetting devices. The instrumentation laboratory will contain inductively coupled plasma, atomic absorption, Moessbauer spectrometers, a carbon analyzer, and ion chromatography equipment. Counting equipment will include intrinsic germanium detectors, scintillation counters, Phoswich alpha, beta, gamma detectors, and a low-energy photon detector

  3. Analytical method for determining colour intensities based on Cherenkov radiation colour quenching

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Gomez, C; Lopez-Gonzalez, J deD; Ferro-Garcia, M A [Univ. of Granada, Granada (Spain). Faculty of Sciences, Dept. of Inorganic Chemistry. Radiochemistry Section; Consejo Superior de Investigaciones Cientificas, Granada (Spain). Dept. of Chemical Research Coordinated Centre)

    1983-01-01

    A study was made for determining color intensities using as luminous non-monochromatic source produced by the Cherenkov emission in the walls of a glass capillary which acts as luminous source itself inside the colored solution to be evaluated. The reproducibility of this method has been compared with the spectrophotometric assay; the relative errors of both analytical methods have been calculated for different concentrations of congo red solution in the range of minimal error, according to Ringbom's criterion. The sensitivity of this analytical method has been studied for the two ..beta..-emitters employed: /sup 90/Sr//sup 90/Y and /sup 204/Tl.

  4. Origin Determination and Differentiation of Gelatin Species of Bovine, Porcine, and Piscine through Analytical Methods

    Directory of Open Access Journals (Sweden)

    Hatice Saadiye Eryılmaz

    2017-06-01

    Full Text Available Gelatin origin determination has been a crucial issue with respect to religion and health concerns. It is necessary to analyze the origin of gelatin with reliable methods to ensure not only consumer choices but also safety and legal requirements such as labeling. There are many analytical methods developed for detection and/or quantification of gelatin from different sources including bovine, porcine and piscine. These analytical methods can be divided into physicochemical, chromatographic, immunochemical, spectroscopic and molecular methods. Moreover, computational methods have been used in some cases consecutively to ensure sensitivity of the analytical methods. Every method has different advantages and limitations due to their own principles, applied food matrix and process conditions of material. The present review intends to give insight into novel analytical methods and perspectives that have been developed to differentiate porcine, bovine and piscine gelatins and to establish their authenticity. Almost every method can be succeeded in origin determination; however, it is a matter of sensitivity in that some researches fail to ensure sufficient differentiation.

  5. Modelling of packet traffic with matrix analytic methods

    DEFF Research Database (Denmark)

    Andersen, Allan T.

    1995-01-01

    BISDN network. The heuristic formula did not seem to yield substantially better results than already available approximations. Finally, some results for the finite capacity BMAP/G/1 queue have been obtained. The steady state probability vector of the embedded chain is found by a direct method where...... process. A heuristic formula for the tail behaviour of a single server queue fed by a superposition of renewal processes has been evaluated. The evaluation was performed by applying Matrix Analytic methods. The heuristic formula has applications in the Call Admission Control (CAC) procedure of the future...

  6. Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey

    Science.gov (United States)

    Arbogast, Belinda F.

    1996-01-01

    The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.

  7. Final report on the proficiency test of the Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network

    International Nuclear Information System (INIS)

    Shakhashiro, A.; Radecki, Z.; Trinkl, A.; Sansone, U.; Benesch, T.

    2005-08-01

    This report presents the statistical evaluation of results from the analysis of 12 radionuclides in 8 samples within the frame of the First Proficiency Test of Analytical Laboratories for the Measurement Environmental RAdioactivity (ALMERA) organized in 2001-2002 by the Chemistry Unit, Agency's Laboratory in Seibersdorf. The results were evaluated by using appropriate statistical means to assess laboratory analytical performance and to estimate the overall performance for the determination of each radionuclide. Evaluation of the analytical data for gamma emitting radionuclides showed that 68% of data obtained a 'Passed' final score for both the trueness and precision criteria applied to this exercise. However, transuranic radionuclides obtained only 58% for the same criteria. (author)

  8. An analytical nodal method for time-dependent one-dimensional discrete ordinates problems

    International Nuclear Information System (INIS)

    Barros, R.C. de

    1992-01-01

    In recent years, relatively little work has been done in developing time-dependent discrete ordinates (S N ) computer codes. Therefore, the topic of time integration methods certainly deserves further attention. In this paper, we describe a new coarse-mesh method for time-dependent monoenergetic S N transport problesm in slab geometry. This numerical method preserves the analytic solution of the transverse-integrated S N nodal equations by constants, so we call our method the analytical constant nodal (ACN) method. For time-independent S N problems in finite slab geometry and for time-dependent infinite-medium S N problems, the ACN method generates numerical solutions that are completely free of truncation errors. Bsed on this positive feature, we expect the ACN method to be more accurate than conventional numerical methods for S N transport calculations on coarse space-time grids

  9. Survey of Technetium Analytical Production Methods Supporting Hanford Nuclear Materials Processing

    International Nuclear Information System (INIS)

    TROYER, G.L.

    1999-01-01

    This document provides a historical survey of analytical methods used for measuring 99 Tc in nuclear fuel reprocessing materials and wastes at Hanford. Method challenges including special sludge matrices tested are discussed. Special problems and recommendations are presented

  10. Analytical Evaluation of Beam Deformation Problem Using Approximate Methods

    DEFF Research Database (Denmark)

    Barari, Amin; Kimiaeifar, A.; Domairry, G.

    2010-01-01

    The beam deformation equation has very wide applications in structural engineering. As a differential equation, it has its own problem concerning existence, uniqueness and methods of solutions. Often, original forms of governing differential equations used in engineering problems are simplified......, and this process produces noise in the obtained answers. This paper deals with the solution of second order of differential equation governing beam deformation using four analytical approximate methods, namely the Perturbation, Homotopy Perturbation Method (HPM), Homotopy Analysis Method (HAM) and Variational...... Iteration Method (VIM). The comparisons of the results reveal that these methods are very effective, convenient and quite accurate for systems of non-linear differential equation....

  11. Assessment of Two Analytical Methods in Solving the Linear and Nonlinear Elastic Beam Deformation Problems

    DEFF Research Database (Denmark)

    Barari, Amin; Ganjavi, B.; Jeloudar, M. Ghanbari

    2010-01-01

    and fluid mechanics. Design/methodology/approach – Two new but powerful analytical methods, namely, He's VIM and HPM, are introduced to solve some boundary value problems in structural engineering and fluid mechanics. Findings – Analytical solutions often fit under classical perturbation methods. However......, as with other analytical techniques, certain limitations restrict the wide application of perturbation methods, most important of which is the dependence of these methods on the existence of a small parameter in the equation. Disappointingly, the majority of nonlinear problems have no small parameter at all......Purpose – In the last two decades with the rapid development of nonlinear science, there has appeared ever-increasing interest of scientists and engineers in the analytical techniques for nonlinear problems. This paper considers linear and nonlinear systems that are not only regarded as general...

  12. Analytical method for the identification and assay of 12 phthalates in cosmetic products: application of the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques".

    Science.gov (United States)

    Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine

    2012-08-31

    Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012

  13. 8. All Polish Conference on Analytical Chemistry: Analytical Chemistry for the Community of the 21. Century

    International Nuclear Information System (INIS)

    Koscielniak, P.; Wieczorek, M.; Kozak, J.

    2010-01-01

    Book of Abstracts contains short descriptions of lectures, communications and posters presented during 8 th All Polish Conference on Analytical Chemistry (Cracow, 4-9.07.2010). Scientific programme consisted of: basic analytical problems, preparation of the samples, chemometry and metrology, miniaturization of the analytical procedures, environmental analysis, medicinal analyses, industrial analyses, food analyses, biochemical analyses, analysis of relicts of the past. Several posters were devoted to the radiochemical separations, radiochemical analysis, environmental behaviour of the elements important for the nuclear science and the professional tests.

  14. Benchmark Comparison of Cloud Analytics Methods Applied to Earth Observations

    Science.gov (United States)

    Lynnes, Chris; Little, Mike; Huang, Thomas; Jacob, Joseph; Yang, Phil; Kuo, Kwo-Sen

    2016-01-01

    Cloud computing has the potential to bring high performance computing capabilities to the average science researcher. However, in order to take full advantage of cloud capabilities, the science data used in the analysis must often be reorganized. This typically involves sharding the data across multiple nodes to enable relatively fine-grained parallelism. This can be either via cloud-based file systems or cloud-enabled databases such as Cassandra, Rasdaman or SciDB. Since storing an extra copy of data leads to increased cost and data management complexity, NASA is interested in determining the benefits and costs of various cloud analytics methods for real Earth Observation cases. Accordingly, NASA's Earth Science Technology Office and Earth Science Data and Information Systems project have teamed with cloud analytics practitioners to run a benchmark comparison on cloud analytics methods using the same input data and analysis algorithms. We have particularly looked at analysis algorithms that work over long time series, because these are particularly intractable for many Earth Observation datasets which typically store data with one or just a few time steps per file. This post will present side-by-side cost and performance results for several common Earth observation analysis operations.

  15. Benchmark Comparison of Cloud Analytics Methods Applied to Earth Observations

    Science.gov (United States)

    Lynnes, C.; Little, M. M.; Huang, T.; Jacob, J. C.; Yang, C. P.; Kuo, K. S.

    2016-12-01

    Cloud computing has the potential to bring high performance computing capabilities to the average science researcher. However, in order to take full advantage of cloud capabilities, the science data used in the analysis must often be reorganized. This typically involves sharding the data across multiple nodes to enable relatively fine-grained parallelism. This can be either via cloud-based filesystems or cloud-enabled databases such as Cassandra, Rasdaman or SciDB. Since storing an extra copy of data leads to increased cost and data management complexity, NASA is interested in determining the benefits and costs of various cloud analytics methods for real Earth Observation cases. Accordingly, NASA's Earth Science Technology Office and Earth Science Data and Information Systems project have teamed with cloud analytics practitioners to run a benchmark comparison on cloud analytics methods using the same input data and analysis algorithms. We have particularly looked at analysis algorithms that work over long time series, because these are particularly intractable for many Earth Observation datasets which typically store data with one or just a few time steps per file. This post will present side-by-side cost and performance results for several common Earth observation analysis operations.

  16. Analytical difficulties facing today's regulatory laboratories: issues in method validation.

    Science.gov (United States)

    MacNeil, James D

    2012-08-01

    The challenges facing analytical laboratories today are not unlike those faced in the past, although both the degree of complexity and the rate of change have increased. Challenges such as development and maintenance of expertise, maintenance and up-dating of equipment, and the introduction of new test methods have always been familiar themes for analytical laboratories, but international guidelines for laboratories involved in the import and export testing of food require management of such changes in a context which includes quality assurance, accreditation, and method validation considerations. Decisions as to when a change in a method requires re-validation of the method or on the design of a validation scheme for a complex multi-residue method require a well-considered strategy, based on a current knowledge of international guidance documents and regulatory requirements, as well the laboratory's quality system requirements. Validation demonstrates that a method is 'fit for purpose', so the requirement for validation should be assessed in terms of the intended use of a method and, in the case of change or modification of a method, whether that change or modification may affect a previously validated performance characteristic. In general, method validation involves method scope, calibration-related parameters, method precision, and recovery. Any method change which may affect method scope or any performance parameters will require re-validation. Some typical situations involving change in methods are discussed and a decision process proposed for selection of appropriate validation measures. © 2012 John Wiley & Sons, Ltd.

  17. Development of analytical methods for the determination of trace elements in sediment with Neutron ActivAtion method (NAA) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Nam, Sang Ho; Kim, Jae Jin; Chung, Yong Sam; Kim, Sun Ha

    2005-01-01

    The analytical methods for the determination of major elements (Al, Ca, K, Fe, Mg) in sediment have been investigated with ICP-MS. The analytical results of major elements with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA. NAA were a little superior to ICP-MS for the determination of major elements in sediment, and NAA is a non-destructive analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) in sediment have been also studied with ICP-MS. The analytical results by standard calibration with ICP-MS were not accurate due to matrix interferences. Thus, internal standard method was applied, then the analytical results for minor element with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments

  18. Advantages of Analytical Transformations in Monte Carlo Methods for Radiation Transport

    International Nuclear Information System (INIS)

    McKinley, M S; Brooks III, E D; Daffin, F

    2004-01-01

    Monte Carlo methods for radiation transport typically attempt to solve an integral by directly sampling analog or weighted particles, which are treated as physical entities. Improvements to the methods involve better sampling, probability games or physical intuition about the problem. We show that significant improvements can be achieved by recasting the equations with an analytical transform to solve for new, non-physical entities or fields. This paper looks at one such transform, the difference formulation for thermal photon transport, showing a significant advantage for Monte Carlo solution of the equations for time dependent transport. Other related areas are discussed that may also realize significant benefits from similar analytical transformations

  19. An efficient analytical method for determination of S-phenylmercapturic acid in urine by HPLC fluorimetric detector to assessing benzene exposure.

    Science.gov (United States)

    Mendes, Michele P Rocha; Silveira, Josianne Nicácio; Andre, Leiliane Coelho

    2017-09-15

    Benzene is an important occupational and environmental contaminant, naturally present in petroleum and as by-product in the steel industry. Toxicological studies showed pronounced myelotoxic action, causing leukemic and others blood cells disorders. Assessing of benzene exposure is performed by biomarkers as trans, trans-muconic acid (AttM) and S-phenylmercapturic acid (S-PMA) in urine. Due to specificity of S-PMA, this biomarker has been proposed to asses lower levels of benzene in air. The aim of this study was to validate an analytical method for the quantification of S-PMA by High-Performance Liquid Chromatography with fluorometric detector. The development of an analytical method of S-PMA in urine was carried out by solid phase extraction (SPE) using C-18 phase. The eluated were submitted to water bath at 75°C and nitrogen to analyte concentration, followed by alkaline hydrolysis and derivatization with monobromobimane. The chromatography conditions were reverse phase C-18 column (240mm, 4mm and 5μm) at 35°C; acetonitrile and 0.5% acetic acid (50:50) as mobile phase with a flow of 0.8mL/min. The limits of detection and quantification were 0.22μg/L and 0.68μg/L, respectively. The linearity was verified by simple linear regression, and the method exhibited good linearity in the range of 10-100μg/L. There was no matrix effect for S-PMA using concentrations of 40, 60, 80 and 100μg/L. The intra- and interassay precision showed coefficient of variation of less than 10% and the recovery ranged from 83.4 to 102.8% with an average of 94.4%. The stability of S-PMA in urine stored at -20°C was of seven weeks. The conclusion is that this method presents satisfactory results per their figures of merit. This proposed method for determining urinary S-PMA showed adequate sensitivity for assessment of occupational and environmental exposure to benzene using S-PMA as biomarker of exposure. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Methods for environmental change; an exploratory study

    Directory of Open Access Journals (Sweden)

    Kok Gerjo

    2012-11-01

    Full Text Available Abstract Background While the interest of health promotion researchers in change methods directed at the target population has a long tradition, interest in change methods directed at the environment is still developing. In this survey, the focus is on methods for environmental change; especially about how these are composed of methods for individual change (‘Bundling’ and how within one environmental level, organizations, methods differ when directed at the management (‘At’ or applied by the management (‘From’. Methods The first part of this online survey dealt with examining the ‘bundling’ of individual level methods to methods at the environmental level. The question asked was to what extent the use of an environmental level method would involve the use of certain individual level methods. In the second part of the survey the question was whether there are differences between applying methods directed ‘at’ an organization (for instance, by a health promoter versus ‘from’ within an organization itself. All of the 20 respondents are experts in the field of health promotion. Results Methods at the individual level are frequently bundled together as part of a method at a higher ecological level. A number of individual level methods are popular as part of most of the environmental level methods, while others are not chosen very often. Interventions directed at environmental agents often have a strong focus on the motivational part of behavior change. There are different approaches targeting a level or being targeted from a level. The health promoter will use combinations of motivation and facilitation. The manager will use individual level change methods focusing on self-efficacy and skills. Respondents think that any method may be used under the right circumstances, although few endorsed coercive methods. Conclusions Taxonomies of theoretical change methods for environmental change should include combinations of individual

  1. THE QuEChERS ANALYTICAL METHOD COMBINED WITH LOW ...

    African Journals Online (AJOL)

    The method has also been applied to different cereal samples and satisfactory average recoveries ... Analysis of multiclass pesticide residues in foods is a challenging task because of the ... compounds set by regulatory bodies. ..... analytes were used to evaluate the influences of the selected factors on performance of the.

  2. MULTIPLE CRITERA METHODS WITH FOCUS ON ANALYTIC HIERARCHY PROCESS AND GROUP DECISION MAKING

    Directory of Open Access Journals (Sweden)

    Lidija Zadnik-Stirn

    2010-12-01

    Full Text Available Managing natural resources is a group multiple criteria decision making problem. In this paper the analytic hierarchy process is the chosen method for handling the natural resource problems. The one decision maker problem is discussed and, three methods: the eigenvector method, data envelopment analysis method, and logarithmic least squares method are presented for the derivation of the priority vector. Further, the group analytic hierarchy process is discussed and six methods for the aggregation of individual judgments or priorities: weighted arithmetic mean method, weighted geometric mean method, and four methods based on data envelopment analysis are compared. The case study on land use in Slovenia is applied. The conclusions review consistency, sensitivity analyses, and some future directions of research.

  3. Analytical methods of heat transfer compared with numerical methods as related to nuclear waste repositories

    International Nuclear Information System (INIS)

    Estrada-Gasca, C.A.

    1986-01-01

    Analytical methods were applied to the prediction of the far-field thermal impact of a nuclear waste repository. Specifically, the transformation of coordinates and the Kirchhoff transformation were used to solve one-dimensional nonlinear heat conduction problems. Calculations for the HLW and TRU nuclear waste with initial areal thermal loadings of 12 kW/acre and 0.7 kW/acre, respectively, are carried out for various models. Also, finite difference and finite element methods are applied. The last method is used to solve two-dimensional linear and nonlinear heat conduction problems. Results of the analysis are temperature distributions and temperature histories. Explicit analytical expressions of the maximum temperature rise as a function of the system parameters are presented. The theoretical approaches predict maximum temperature increases in the overburden with an error of 10%. When the finite solid one-dimensional NWR thermal problem is solved with generic salt and HLW thermal load as parameters, the maximum temperature rises predicted by the finite difference and finite element methods had maximum errors of 2.6 and 6.7%, respectively. In all the other cases the finite difference method also gave a smaller error than the finite element method

  4. Developing automated analytical methods for scientific environments using LabVIEW.

    Science.gov (United States)

    Wagner, Christoph; Armenta, Sergio; Lendl, Bernhard

    2010-01-15

    The development of new analytical techniques often requires the building of specially designed devices, each requiring its own dedicated control software. Especially in the research and development phase, LabVIEW has proven to be one highly useful tool for developing this software. Yet, it is still common practice to develop individual solutions for different instruments. In contrast to this, we present here a single LabVIEW-based program that can be directly applied to various analytical tasks without having to change the program code. Driven by a set of simple script commands, it can control a whole range of instruments, from valves and pumps to full-scale spectrometers. Fluid sample (pre-)treatment and separation procedures can thus be flexibly coupled to a wide range of analytical detection methods. Here, the capabilities of the program have been demonstrated by using it for the control of both a sequential injection analysis - capillary electrophoresis (SIA-CE) system with UV detection, and an analytical setup for studying the inhibition of enzymatic reactions using a SIA system with FTIR detection.

  5. Vertical equilibrium with sub-scale analytical methods for geological CO2 sequestration

    KAUST Repository

    Gasda, S. E.

    2009-04-23

    Large-scale implementation of geological CO2 sequestration requires quantification of risk and leakage potential. One potentially important leakage pathway for the injected CO2 involves existing oil and gas wells. Wells are particularly important in North America, where more than a century of drilling has created millions of oil and gas wells. Models of CO 2 injection and leakage will involve large uncertainties in parameters associated with wells, and therefore a probabilistic framework is required. These models must be able to capture both the large-scale CO 2 plume associated with the injection and the small-scale leakage problem associated with localized flow along wells. Within a typical simulation domain, many hundreds of wells may exist. One effective modeling strategy combines both numerical and analytical models with a specific set of simplifying assumptions to produce an efficient numerical-analytical hybrid model. The model solves a set of governing equations derived by vertical averaging with assumptions of a macroscopic sharp interface and vertical equilibrium. These equations are solved numerically on a relatively coarse grid, with an analytical model embedded to solve for wellbore flow occurring at the sub-gridblock scale. This vertical equilibrium with sub-scale analytical method (VESA) combines the flexibility of a numerical method, allowing for heterogeneous and geologically complex systems, with the efficiency and accuracy of an analytical method, thereby eliminating expensive grid refinement for sub-scale features. Through a series of benchmark problems, we show that VESA compares well with traditional numerical simulations and to a semi-analytical model which applies to appropriately simple systems. We believe that the VESA model provides the necessary accuracy and efficiency for applications of risk analysis in many CO2 sequestration problems. © 2009 Springer Science+Business Media B.V.

  6. Methods for environmental change; an exploratory study.

    Science.gov (United States)

    Kok, Gerjo; Gottlieb, Nell H; Panne, Robert; Smerecnik, Chris

    2012-11-28

    While the interest of health promotion researchers in change methods directed at the target population has a long tradition, interest in change methods directed at the environment is still developing. In this survey, the focus is on methods for environmental change; especially about how these are composed of methods for individual change ('Bundling') and how within one environmental level, organizations, methods differ when directed at the management ('At') or applied by the management ('From'). The first part of this online survey dealt with examining the 'bundling' of individual level methods to methods at the environmental level. The question asked was to what extent the use of an environmental level method would involve the use of certain individual level methods. In the second part of the survey the question was whether there are differences between applying methods directed 'at' an organization (for instance, by a health promoter) versus 'from' within an organization itself. All of the 20 respondents are experts in the field of health promotion. Methods at the individual level are frequently bundled together as part of a method at a higher ecological level. A number of individual level methods are popular as part of most of the environmental level methods, while others are not chosen very often. Interventions directed at environmental agents often have a strong focus on the motivational part of behavior change.There are different approaches targeting a level or being targeted from a level. The health promoter will use combinations of motivation and facilitation. The manager will use individual level change methods focusing on self-efficacy and skills. Respondents think that any method may be used under the right circumstances, although few endorsed coercive methods. Taxonomies of theoretical change methods for environmental change should include combinations of individual level methods that may be bundled and separate suggestions for methods targeting a level

  7. The fitness for purpose of analytical methods applied to fluorimetric uranium determination in water matrix

    International Nuclear Information System (INIS)

    Grinman, Ana; Giustina, Daniel; Mondini, Julia; Diodat, Jorge

    2008-01-01

    Full text: This paper describes the steps which should be followed by a laboratory in order to validate the fluorimetric method for natural uranium in water matrix. The validation of an analytical method is a necessary requirement prior accreditation under Standard norm ISO/IEC 17025, of a non normalized method. Different analytical techniques differ in a sort of variables to be validated. Depending on the chemical process, measurement technique, matrix type, data fitting and measurement efficiency, a laboratory must set up experiments to verify reliability of data, through the application of several statistical tests and by participating in Quality Programs (QP) organized by reference laboratories such as the National Institute of Standards and Technology (NIST), National Physics Laboratory (NPL), or Environmental Measurements Laboratory (EML). However, the participation in QP not only involves international reference laboratories, but also, the national ones which are able to prove proficiency to the Argentinean Accreditation Board. The parameters that the ARN laboratory had to validate in the fluorimetric method to fit in accordance with Eurachem guide and IUPAC definitions, are: Detection Limit, Quantification Limit, Precision, Intra laboratory Precision, Reproducibility Limit, Repeatability Limit, Linear Range and Robustness. Assays to fit the above parameters were designed on the bases of statistics requirements, and a detailed data treatment is presented together with the respective tests in order to show the parameters validated. As a final conclusion, the uranium determination by fluorimetry is a reliable method for direct measurement to meet radioprotection requirements in water matrix, within its linear range which is fixed every time a calibration is carried out at the beginning of the analysis. The detection limit ( depending on blank standard deviation and slope) varies between 3 ug U and 5 ug U which yields minimum detectable concentrations (MDC) of

  8. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  9. Methods and techniques for prediction of environmental impact

    International Nuclear Information System (INIS)

    1992-04-01

    Environmental impact assessment (EIA) is the procedure that helps decision makers understand the environmental implications of their decisions. The prediction of environmental effects or impact is an extremely important part of the EIA procedure and improvements in existing capabilities are needed. Considerable attention is paid within environmental impact assessment and in handbooks on EIA to methods for identifying and evaluating environmental impacts. However, little attention is given to the issue distribution of information on impact prediction methods. The quantitative or qualitative methods for the prediction of environmental impacts appear to be the two basic approaches for incorporating environmental concerns into the decision-making process. Depending on the nature of the proposed activity and the environment likely to be affected, a combination of both quantitative and qualitative methods is used. Within environmental impact assessment, the accuracy of methods for the prediction of environmental impacts is of major importance while it provides for sound and well-balanced decision making. Pertinent and effective action to deal with the problems of environmental protection and the rational use of natural resources and sustainable development is only possible given objective methods and techniques for the prediction of environmental impact. Therefore, the Senior Advisers to ECE Governments on Environmental and Water Problems, decided to set up a task force, with the USSR as lead country, on methods and techniques for the prediction of environmental impacts in order to undertake a study to review and analyse existing methodological approaches and to elaborate recommendations to ECE Governments. The work of the task force was completed in 1990 and the resulting report, with all relevant background material, was approved by the Senior Advisers to ECE Governments on Environmental and Water Problems in 1991. The present report reflects the situation, state of

  10. Analytical methods for determination of free metal ion concentration, labile species fraction and metal complexation capacity of environmental waters: a review.

    Science.gov (United States)

    Pesavento, Maria; Alberti, Giancarla; Biesuz, Raffaela

    2009-01-12

    Different experimental approaches have been suggested in the last few decades to determine metal species in complex matrices of unknown composition as environmental waters. The methods are mainly focused on the determination of single species or groups of species. The more recent developments in trace elements speciation are reviewed focusing on methods for labile and free metal determination. Electrochemical procedures with low detection limit as anodic stripping voltammetry (ASV) and the competing ligand exchange with adsorption cathodic stripping voltammetry (CLE-AdCSV) have been widely employed in metal distribution studies in natural waters. Other electrochemical methods such as stripping chronopotentiometry and AGNES seem to be promising to evaluate the free metal concentration at the low levels of environmental samples. Separation techniques based on ion exchange (IE) and complexing resins (CR), and micro separation methods as the Donnan membrane technique (DMT), diffusive gradients in thin-film gels (DGT) and the permeation liquid membrane (PLM), are among the non-electrochemical methods largely used in this field and reviewed in the text. Under appropriate conditions such techniques make possible the evaluation of free metal ion concentration.

  11. Advances in the Analytical Methods for Determining the Antioxidant ...

    African Journals Online (AJOL)

    Advances in the Analytical Methods for Determining the Antioxidant Properties of Honey: A Review. M Moniruzzaman, MI Khalil, SA Sulaiman, SH Gan. Abstract. Free radicals and reactive oxygen species (ROS) have been implicated in contributing to the processes of aging and disease. In an effort to combat free radical ...

  12. Analytical method and result of radiation exposure for depressurization accident of HTTR

    International Nuclear Information System (INIS)

    Sawa, K.; Shiozawa, S.; Mikami, H.

    1990-01-01

    The Japan Atomic Energy Research Institute (JAERI) is now proceeding with the construction design of the High Temperature Engineering Test Reactor (HTTR). Since the HTTR has some characteristics different from LWRs, analytical method of radiation exposure in accidents provided for LWRs can not be applied directly. This paper describes the analytical method of radiation exposure developed by JAERI for the depressurization accident, which is the severest accident in respect to radiation exposure among the design basis accidents of the HTTR. The result is also described in this paper

  13. Role of the IAEA's ALMERA network in harmonization of analytical procedures applicable worldwide for radiological emergencies

    International Nuclear Information System (INIS)

    Pitois, A.; Osvath, I.; Tarjan, S.; Groening, M.; Osborn, D.; )

    2016-01-01

    The International Atomic Energy Agency (IAEA) coordinates and provides analytical support to the worldwide network of Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA), consisting at the end of 2015 of 154 laboratories in 85 countries. This network, established by the IAEA in 1995, has for aim to provide timely and reliable measurement results of environmental radioactivity in routine monitoring and emergency situations. The IAEA supports the ALMERA laboratories in their routine and emergency response environmental monitoring activities by organizing proficiency tests and inter-laboratory comparison exercises, developing validated analytical procedures for environmental radioactivity measurement, and organizing training courses and workshops. The network also acts as a forum for sharing knowledge and expertise. The aim of this paper is to describe the current status of ALMERA analytical method development activities for radiological emergencies and the plans for further development in the field

  14. Simplified Analytical Methods to Analyze Lock Gates Submitted to Ship Collisions and Earthquakes

    Directory of Open Access Journals (Sweden)

    Buldgen Loic

    2015-09-01

    Full Text Available This paper presents two simplified analytical methods to analyze lock gates submitted to two different accidental loads. The case of an impact involving a vessel is first investigated. In this situation, the resistance of the struck gate is evaluated by assuming a local and a global deforming mode. The super-element method is used in the first case, while an equivalent beam model is simultaneously introduced to capture the overall bending motion of the structure. The second accidental load considered in this paper is the seismic action, for which an analytical method is presented to evaluate the total hydrodynamic pressure applied on a lock gate during an earthquake, due account being taken of the fluid-structure interaction. For each of these two actions, numerical validations are presented and the analytical results are compared to finite-element solutions.

  15. Investigation by perturbative and analytical method of electronic properties of square quantum well under electric field

    Directory of Open Access Journals (Sweden)

    Mustafa Kemal BAHAR

    2010-06-01

    Full Text Available In this study, the effects of applied electric field on the isolated square quantum well was investigated by analytic and perturbative method. The energy eigen values and wave functions in quantum well were found by perturbative method. Later, the electric field effects were investigated by analytic method, the results of perturbative and analytic method were compared. As well as both of results fit with each other, it was observed that externally applied electric field changed importantly electronic properties of the system.

  16. Microgenetic Learning Analytics Methods: Workshop Report

    Science.gov (United States)

    Aghababyan, Ani; Martin, Taylor; Janisiewicz, Philip; Close, Kevin

    2016-01-01

    Learning analytics is an emerging discipline and, as such, benefits from new tools and methodological approaches. This work reviews and summarizes our workshop on microgenetic data analysis techniques using R, held at the second annual Learning Analytics Summer Institute in Cambridge, Massachusetts, on 30 June 2014. Specifically, this paper…

  17. Comparative analysis of methods for real-time analytical control of chemotherapies preparations.

    Science.gov (United States)

    Bazin, Christophe; Cassard, Bruno; Caudron, Eric; Prognon, Patrice; Havard, Laurent

    2015-10-15

    Control of chemotherapies preparations are now an obligation in France, though analytical control is compulsory. Several methods are available and none of them is presumed as ideal. We wanted to compare them so as to determine which one could be the best choice. We compared non analytical (visual and video-assisted, gravimetric) and analytical (HPLC/FIA, UV/FT-IR, UV/Raman, Raman) methods thanks to our experience and a SWOT analysis. The results of the analysis show great differences between the techniques, but as expected none us them is without defects. However they can probably be used in synergy. Overall for the pharmacist willing to get involved, the implementation of the control for chemotherapies preparations must be widely anticipated, with the listing of every parameter, and remains according to us an analyst's job. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Application of Multi-Analyte Methods for Pesticide Formulations

    Energy Technology Data Exchange (ETDEWEB)

    Lantos, J.; Virtics, I. [Plant Protection & Soil Conservation Service of Szabolcs-Szatmár-Bereg County, Nyíregyháza (Hungary)

    2009-07-15

    The application of multi-analyte methods for pesticide formulations by GC analysis is discussed. HPLC was used to determine active ingredients. HPLC elution sequences were related to individual n-octanol/water partition coefficients. Real laboratory data are presented and evaluated with regard to validation requirements. The retention time data of pesticides on different HPLC columns under gradient and isocratic conditions are compared to illustrate the applicability of the methodologies. (author)

  19. Analytic methods for field induced tunneling in quantum wells

    Indian Academy of Sciences (India)

    Analytic methods for field induced tunneling in quantum wells with arbitrary potential profiles ... Electric field induced tunneling is studied in three different types of quantum wells by solving time-independent effective mass ... Current Issue : Vol.

  20. A sample preparation method for recovering suppressed analyte ions in MALDI TOF MS

    NARCIS (Netherlands)

    Lou, X.; Waal, de B.F.M.; Milroy, L.G.; Dongen, van J.L.J.

    2015-01-01

    In matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS), analyte signals can be substantially suppressed by other compounds in the sample. In this technical note, we describe a modified thin-layer sample preparation method that significantly reduces the analyte

  1. Environmental research organizations and climate change policy analytical capacity : an assessment of the Canadian case

    International Nuclear Information System (INIS)

    Howlett, M.; Oliphant, S.

    2010-01-01

    Climate change is a topic of increasing interest to contemporary decision makers. In order for governments to make informed decisions in climate change mitigation and adaptation efforts, environmental policy makers require strong research and analytical capabilities to design and implement effective policies to deal with wide-ranging and complex policy issues. This articles presented a 7-criteria model of policy analytical capacity (PAC) and applied it to 3 prominent Canadian environmental policy research organizations. The 2 governmental organizations examined in this study were Environment Canada and the British Columbia Ministry of the Environment, while the non-government organization was the David Suzuki Foundation. Following the 7 principles that determine the PAC of an organization, each case study examined the education/training of the organization's employees; the types and mix of policy analysis techniques used by the organization; the culture and structure of decision making in the organization; the nature and source of demand for the organization's research; and the organization's access to necessary data and information to conduct work at a high level of competence. Interview data provided information on the status of each organizations' current research capacity and the effect this has on overall government policy-making capability in the face of climate change challenges. 75 refs.

  2. Analytical methods in rotor dynamics

    CERN Document Server

    Dimarogonas, Andrew D; Chondros, Thomas G

    2013-01-01

    The design and construction of rotating machinery operating at supercritical speeds was, in the 1920s, an event of revolutionary importance for the then new branch of dynamics known as rotor dynamics. In the 1960s, another revolution occurred: In less than a decade, imposed by operational and economic needs, an increase in the power of turbomachinery by one order of magnitude took place. Dynamic analysis of complex rotor forms became a necessity, while the importance of approximate methods for dynamic analysis was stressed. Finally, the emergence of fracture mechanics, as a new branch of applied mechanics, provided analytical tools to investigate crack influence on the dynamic behavior of rotors. The scope of this book is based on all these developments. No topics related to the well-known classical problems are included, rather the book deals exclusively with modern high-power turbomachinery.

  3. Analytic function expansion nodal method for nuclear reactor core design

    International Nuclear Information System (INIS)

    Noh, Hae Man

    1995-02-01

    In most advanced nodal methods the transverse integration is commonly used to reduce the multi-dimensional diffusion equation into equivalent one- dimensional diffusion equations when derving the nodal coupling equations. But the use of the transverse integration results in some limitations. The first limitation is that the transverse leakage term which appears in the transverse integration procedure must be appropriately approximated. The second limitation is that the one-dimensional flux shapes in each spatial direction resulted from the nodal calculation are not accurate enough to be directly used in reconstructing the pinwise flux distributions. Finally the transverse leakage defined for a non-rectangular node such as a hexagonal node or a triangular node is too complicated to be easily handled and may contain non-physical singular terms of step-function and delta-function types. In this thesis, the Analytic Function Expansion Nodal (AFEN) method and its two variations : the Polynomial Expansion Nodal (PEN) method and the hybrid of the AFEN and PEN methods, have been developed to overcome the limitations of the transverse integration procedure. All of the methods solve the multidimensional diffusion equation without the transverse integration. The AFEN method which we believe is the major contribution of this study to the reactor core analysis expands the homogeneous flux distributions within a node in non-separable analytic basis functions satisfying the neutron diffusion equations at any point of the node and expresses the coefficients of the flux expansion in terms of the nodal unknowns which comprise a node-average flux, node-interface fluxes, and corner-point fluxes. Then, the nodal coupling equations composed of the neutron balance equations, the interface current continuity equations, and the corner-point leakage balance equations are solved iteratively to determine all the nodal unknowns. Since the AFEN method does not use the transverse integration in

  4. Evaluation and selection of energy technologies using an integrated graph theory and analytic hierarchy process methods

    Directory of Open Access Journals (Sweden)

    P. B. Lanjewar

    2016-06-01

    Full Text Available The evaluation and selection of energy technologies involve a large number of attributes whose selection and weighting is decided in accordance with the social, environmental, technical and economic framework. In the present work an integrated multiple attribute decision making methodology is developed by combining graph theory and analytic hierarchy process methods to deal with the evaluation and selection of energy technologies. The energy technology selection attributes digraph enables a quick visual appraisal of the energy technology selection attributes and their interrelationships. The preference index provides a total objective score for comparison of energy technologies alternatives. Application of matrix permanent offers a better appreciation of the considered attributes and helps to analyze the different alternatives from combinatorial viewpoint. The AHP is used to assign relative weights to the attributes. Four examples of evaluation and selection of energy technologies are considered in order to demonstrate and validate the proposed method.

  5. Improvement of spatial discretization error on the semi-analytic nodal method using the scattered source subtraction method

    International Nuclear Information System (INIS)

    Yamamoto, Akio; Tatsumi, Masahiro

    2006-01-01

    In this paper, the scattered source subtraction (SSS) method is newly proposed to improve the spatial discretization error of the semi-analytic nodal method with the flat-source approximation. In the SSS method, the scattered source is subtracted from both side of the diffusion or the transport equation to make spatial variation of the source term to be small. The same neutron balance equation is still used in the SSS method. Since the SSS method just modifies coefficients of node coupling equations (those used in evaluation for the response of partial currents), its implementation is easy. Validity of the present method is verified through test calculations that are carried out in PWR multi-assemblies configurations. The calculation results show that the SSS method can significantly improve the spatial discretization error. Since the SSS method does not have any negative impact on execution time, convergence behavior and memory requirement, it will be useful to reduce the spatial discretization error of the semi-analytic nodal method with the flat-source approximation. (author)

  6. Heat Conduction Analysis Using Semi Analytical Finite Element Method

    International Nuclear Information System (INIS)

    Wargadipura, A. H. S.

    1997-01-01

    Heat conduction problems are very often found in science and engineering fields. It is of accrual importance to determine quantitative descriptions of this important physical phenomena. This paper discusses the development and application of a numerical formulation and computation that can be used to analyze heat conduction problems. The mathematical equation which governs the physical behaviour of heat conduction is in the form of second order partial differential equations. The numerical resolution used in this paper is performed using the finite element method and Fourier series, which is known as semi-analytical finite element methods. The numerical solution results in simultaneous algebraic equations which is solved using the Gauss elimination methodology. The computer implementation is carried out using FORTRAN language. In the final part of the paper, a heat conduction problem in a rectangular plate domain with isothermal boundary conditions in its edge is solved to show the application of the computer program developed and also a comparison with analytical solution is discussed to assess the accuracy of the numerical solution obtained

  7. Multiplier ideal sheaves and analytic methods in algebraic geometry

    International Nuclear Information System (INIS)

    Demailly, J.-P.

    2001-01-01

    Our main purpose here is to describe a few analytic tools which are useful to study questions such as linear series and vanishing theorems for algebraic vector bundles. One of the early successes of analytic methods in this context is Kodaira's use of the Bochner technique in relation with the theory of harmonic forms, during the decade 1950-60.The idea is to represent cohomology classes by harmonic forms and to prove vanishing theorems by means of suitable a priori curvature estimates. We pursue the study of L2 estimates, in relation with the Nullstellenstatz and with the extension problem. We show how subadditivity can be used to derive an approximation theorem for (almost) plurisubharmonic functions: any such function can be approximated by a sequence of (almost) plurisubharmonic functions which are smooth outside an analytic set, and which define the same multiplier ideal sheaves. From this, we derive a generalized version of the hard Lefschetz theorem for cohomology with values in a pseudo-effective line bundle; namely, the Lefschetz map is surjective when the cohomology groups are twisted by the relevant multiplier ideal sheaves. These notes are essentially written with the idea of serving as an analytic tool- box for algebraic geometers. Although efficient algebraic techniques exist, our feeling is that the analytic techniques are very flexible and offer a large variety of guidelines for more algebraic questions (including applications to number theory which are not discussed here). We made a special effort to use as little prerequisites and to be as self-contained as possible; hence the rather long preliminary sections dealing with basic facts of complex differential geometry

  8. Multiplier ideal sheaves and analytic methods in algebraic geometry

    Energy Technology Data Exchange (ETDEWEB)

    Demailly, J -P [Universite de Grenoble I, Institut Fourier, Saint-Martin d' Heres (France)

    2001-12-15

    Our main purpose here is to describe a few analytic tools which are useful to study questions such as linear series and vanishing theorems for algebraic vector bundles. One of the early successes of analytic methods in this context is Kodaira's use of the Bochner technique in relation with the theory of harmonic forms, during the decade 1950-60.The idea is to represent cohomology classes by harmonic forms and to prove vanishing theorems by means of suitable a priori curvature estimates. We pursue the study of L2 estimates, in relation with the Nullstellenstatz and with the extension problem. We show how subadditivity can be used to derive an approximation theorem for (almost) plurisubharmonic functions: any such function can be approximated by a sequence of (almost) plurisubharmonic functions which are smooth outside an analytic set, and which define the same multiplier ideal sheaves. From this, we derive a generalized version of the hard Lefschetz theorem for cohomology with values in a pseudo-effective line bundle; namely, the Lefschetz map is surjective when the cohomology groups are twisted by the relevant multiplier ideal sheaves. These notes are essentially written with the idea of serving as an analytic tool- box for algebraic geometers. Although efficient algebraic techniques exist, our feeling is that the analytic techniques are very flexible and offer a large variety of guidelines for more algebraic questions (including applications to number theory which are not discussed here). We made a special effort to use as little prerequisites and to be as self-contained as possible; hence the rather long preliminary sections dealing with basic facts of complex differential geometry.

  9. Status of photonuclear method of analysis among other nuclear analytical methods and main fields of its application

    International Nuclear Information System (INIS)

    Burmistenko, Yu.N.

    1986-01-01

    Technical, organizational and economical aspects as applied to the field of application of photonuclear methods of analysis of substance composition are considered. As for the technical aspect, the most important factors are nuclear-physical characteristics of the elements under determination and the elements composing the sample matrix. As for the organizational aspect, the governing factor in a number of cases is the availability of an irradiation device in the close vicinity of the analytical laboratory. Studying the technical and organizational aspects while choosing the proper method one can obtain the main source data to perform feasibility studies of a nuclear analytical complex with this or that activation source. Therefore, the economical aspect is governing for the choice of the method

  10. A Table Lookup Method for Exact Analytical Solutions of Nonlinear Fractional Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    Ji Juan-Juan

    2017-01-01

    Full Text Available A table lookup method for solving nonlinear fractional partial differential equations (fPDEs is proposed in this paper. Looking up the corresponding tables, we can quickly obtain the exact analytical solutions of fPDEs by using this method. To illustrate the validity of the method, we apply it to construct the exact analytical solutions of four nonlinear fPDEs, namely, the time fractional simplified MCH equation, the space-time fractional combined KdV-mKdV equation, the (2+1-dimensional time fractional Zoomeron equation, and the space-time fractional ZKBBM equation. As a result, many new types of exact analytical solutions are obtained including triangular periodic solution, hyperbolic function solution, singular solution, multiple solitary wave solution, and Jacobi elliptic function solution.

  11. Analytical Chemistry Laboratory, progress report for FY 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-01

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year (FY) 1993 (October 1992 through September 1993). This annual report is the tenth for the ACL and describes continuing effort on projects, work on new projects, and contributions of the ACL staff to various programs at ANL. The Analytical Chemistry Laboratory is a full-cost-recovery service center, with the primary mission of providing a broad range of analytical chemistry support services to the scientific and engineering programs at ANL. The ACL also has research programs in analytical chemistry, conducts instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL handles a wide range of analytical problems. Some routine or standard analyses are done, but it is common for the Argonne programs to generate unique problems that require development or modification of methods and adaption of techniques to obtain useful analytical data. The ACL is administratively within the Chemical Technology Division (CMT), its principal ANL client, but provides technical support for many of the technical divisions and programs at ANL. The ACL has four technical groups--Chemical Analysis, Instrumental Analysis, Organic Analysis, and Environmental Analysis--which together include about 45 technical staff members. Talents and interests of staff members cross the group lines, as do many projects within the ACL.

  12. An analytically based numerical method for computing view factors in real urban environments

    Science.gov (United States)

    Lee, Doo-Il; Woo, Ju-Wan; Lee, Sang-Hyun

    2018-01-01

    A view factor is an important morphological parameter used in parameterizing in-canyon radiative energy exchange process as well as in characterizing local climate over urban environments. For realistic representation of the in-canyon radiative processes, a complete set of view factors at the horizontal and vertical surfaces of urban facets is required. Various analytical and numerical methods have been suggested to determine the view factors for urban environments, but most of the methods provide only sky-view factor at the ground level of a specific location or assume simplified morphology of complex urban environments. In this study, a numerical method that can determine the sky-view factors ( ψ ga and ψ wa ) and wall-view factors ( ψ gw and ψ ww ) at the horizontal and vertical surfaces is presented for application to real urban morphology, which are derived from an analytical formulation of the view factor between two blackbody surfaces of arbitrary geometry. The established numerical method is validated against the analytical sky-view factor estimation for ideal street canyon geometries, showing a consolidate confidence in accuracy with errors of less than 0.2 %. Using a three-dimensional building database, the numerical method is also demonstrated to be applicable in determining the sky-view factors at the horizontal (roofs and roads) and vertical (walls) surfaces in real urban environments. The results suggest that the analytically based numerical method can be used for the radiative process parameterization of urban numerical models as well as for the characterization of local urban climate.

  13. 8. Latin American Symposium on Environmental and Sanitary Analytical Chemistry: abstracts

    International Nuclear Information System (INIS)

    2009-01-01

    The rapid changes and development of world economy, incidental to continued growth in consumption of industrial goods, continue presenting biological and biochemical interactions unsuspected or underestimated. This has imposed increasing challenges in the study of the effects on human health and environmental, vital issues that affect all citizens of the planet and the biota in general, but have not yet been sufficiently studied or well understood. Stringent criteria are needed to determine the impacts on health, long-term, of technical and chemical inventions today. This movement has received support from consumers and politicians, in the case of the European Union, the largest common market in the world. Large employers already know that it is necessary to develop the new green technology and its controls, if they are to survive in the global economy of a future that is next. The countries of the great region of Latin America have presented a specific weight very noticeable on the world community and have not been independent of the process generalized and they also correspond to scientifically scrutinize the environmental interactive phenomena to deal with possible negative consequences, give solutions and options satisfactory to their leaders and its population. The scientific program included new techniques, qualitative and quantitative, applied to the determination of substances and microorganisms in organisms and ecosystems. The evaluation of the effects of pollution on the environment has been focused so, as the development of standards for pollution control and various activities related to the study and solution of environmental problems facing the area. Abstracts of oral presentations and posters that were presented at the 8th Latin American Symposium on Environmental Analytical Chemistry and Health were included in this compendium. (author) [es

  14. Numerical methods: Analytical benchmarking in transport theory

    International Nuclear Information System (INIS)

    Ganapol, B.D.

    1988-01-01

    Numerical methods applied to reactor technology have reached a high degree of maturity. Certainly one- and two-dimensional neutron transport calculations have become routine, with several programs available on personal computer and the most widely used programs adapted to workstation and minicomputer computational environments. With the introduction of massive parallelism and as experience with multitasking increases, even more improvement in the development of transport algorithms can be expected. Benchmarking an algorithm is usually not a very pleasant experience for the code developer. Proper algorithmic verification by benchmarking involves the following considerations: (1) conservation of particles, (2) confirmation of intuitive physical behavior, and (3) reproduction of analytical benchmark results. By using today's computational advantages, new basic numerical methods have been developed that allow a wider class of benchmark problems to be considered

  15. Analytical quality by design: a tool for regulatory flexibility and robust analytics.

    Science.gov (United States)

    Peraman, Ramalingam; Bhadraya, Kalva; Padmanabha Reddy, Yiragamreddy

    2015-01-01

    Very recently, Food and Drug Administration (FDA) has approved a few new drug applications (NDA) with regulatory flexibility for quality by design (QbD) based analytical approach. The concept of QbD applied to analytical method development is known now as AQbD (analytical quality by design). It allows the analytical method for movement within method operable design region (MODR). Unlike current methods, analytical method developed using analytical quality by design (AQbD) approach reduces the number of out-of-trend (OOT) results and out-of-specification (OOS) results due to the robustness of the method within the region. It is a current trend among pharmaceutical industry to implement analytical quality by design (AQbD) in method development process as a part of risk management, pharmaceutical development, and pharmaceutical quality system (ICH Q10). Owing to the lack explanatory reviews, this paper has been communicated to discuss different views of analytical scientists about implementation of AQbD in pharmaceutical quality system and also to correlate with product quality by design and pharmaceutical analytical technology (PAT).

  16. Simplified Analytical Method for Optimized Initial Shape Analysis of Self-Anchored Suspension Bridges and Its Verification

    Directory of Open Access Journals (Sweden)

    Myung-Rag Jung

    2015-01-01

    Full Text Available A simplified analytical method providing accurate unstrained lengths of all structural elements is proposed to find the optimized initial state of self-anchored suspension bridges under dead loads. For this, equilibrium equations of the main girder and the main cable system are derived and solved by evaluating the self-weights of cable members using unstrained cable lengths and iteratively updating both the horizontal tension component and the vertical profile of the main cable. Furthermore, to demonstrate the validity of the simplified analytical method, the unstrained element length method (ULM is applied to suspension bridge models based on the unstressed lengths of both cable and frame members calculated from the analytical method. Through numerical examples, it is demonstrated that the proposed analytical method can indeed provide an optimized initial solution by showing that both the simplified method and the nonlinear FE procedure lead to practically identical initial configurations with only localized small bending moment distributions.

  17. Extraction of fullerenes from environmental matrices as affected by solvent characteristics and analyte concentration.

    Science.gov (United States)

    Place, Benjamin J; Kleber, Markus; Field, Jennifer A

    2013-03-01

    Fullerenes possess unique chemical properties that make the isolation of these compounds from heterogeneous environmental matrices difficult. For example, previous reports indicate that toluene-based extraction techniques vary in their ability to extract C60, especially from highly carbonaceous solid matrices. Here, we examined the effects of (i) solvent type (toluene alone versus an 80:20 v/v mixture of toluene and 1-methylnaphthalene) and (ii) analyte concentration on the extraction efficiency of an isotopically labeled surrogate compound, (13)C60. The toluene/1-methylnaphthalene mixture increased fullerene extraction efficiency from carbon lampblack by a factor of five, but was not significantly different from 100% toluene when applied to wood stove soot or montmorillonite. Recovery of the (13)C60 surrogate declined with decreasing analyte concentration. The usefulness of isotopically labeled surrogate is demonstrated and the study provides a quantitative assessment regarding the dependence of fullerene extraction efficiencies on the geochemical characteristics of solid matrices. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Analytical method for estimating the thermal expansion coefficient of metals at high temperature

    International Nuclear Information System (INIS)

    Takamoto, S; Izumi, S; Nakata, T; Sakai, S; Oinuma, S; Nakatani, Y

    2015-01-01

    In this paper, we propose an analytical method for estimating the thermal expansion coefficient (TEC) of metals at high-temperature ranges. Although the conventional method based on quasiharmonic approximation (QHA) shows good results at low temperatures, anharmonic effects caused by large-amplitude thermal vibrations reduces its accuracy at high temperatures. Molecular dynamics (MD) naturally includes the anharmonic effect. However, since the computational cost of MD is relatively high, in order to make an interatomic potential capable of reproducing TEC, an analytical method is essential. In our method, analytical formulation of the radial distribution function (RDF) at finite temperature realizes the estimation of the TEC. Each peak of the RDF is approximated by the Gaussian distribution. The average and variance of the Gaussian distribution are formulated by decomposing the fluctuation of interatomic distance into independent elastic waves. We incorporated two significant anharmonic effects into the method. One is the increase in the averaged interatomic distance caused by large amplitude vibration. The second is the variation in the frequency of elastic waves. As a result, the TECs of fcc and bcc crystals estimated by our method show good agreement with those of MD. Our method enables us to make an interatomic potential that reproduces the TEC at high temperature. We developed the GEAM potential for nickel. The TEC of the fitted potential showed good agreement with experimental data from room temperature to 1000 K. As compared with the original potential, it was found that the third derivative of the wide-range curve was modified, while the zeroth, first and second derivatives were unchanged. This result supports the conventional theory of solid state physics. We believe our analytical method and developed interatomic potential will contribute to future high-temperature material development. (paper)

  19. Analytical Chemistry Laboratory Progress Report for FY 1994

    Energy Technology Data Exchange (ETDEWEB)

    Green, D.W.; Boparai, A.S.; Bowers, D.L. [and others

    1994-12-01

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year (FY) 1994 (October 1993 through September 1994). This annual report is the eleventh for the ACL and describes continuing effort on projects, work on new projects, and contributions of the ACL staff to various programs at ANL. The Analytical Chemistry Laboratory is a full-cost-recovery service center, with the primary mission of providing a broad range of analytical chemistry support services to the scientific and engineering programs at ANL. The ACL also has a research program in analytical chemistry, conducts instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL handles a wide range of analytical problems. Some routine or standard analyses are done, but it is common for the Argonne programs to generate unique problems that require significant development of methods and adaption of techniques to obtain useful analytical data. The ACL has four technical groups -- Chemical Analysis, Instrumental Analysis, Organic Analysis, and Environmental Analysis -- which together include about 45 technical staff members. Talents and interests of staff members cross the group lines, as do many projects within the ACL. The Chemical Analysis Group uses wet- chemical and instrumental methods for elemental, compositional, and isotopic determinations in solid, liquid, and gaseous samples and provides specialized analytical services. Major instruments in this group include an ion chromatograph (IC), an inductively coupled plasma/atomic emission spectrometer (ICP/AES), spectrophotometers, mass spectrometers (including gas-analysis and thermal-ionization mass spectrometers), emission spectrographs, autotitrators, sulfur and carbon determinators, and a kinetic phosphorescence uranium analyzer.

  20. Method for environmental risk analysis (MIRA) revision 2007

    International Nuclear Information System (INIS)

    2007-04-01

    OLF's instruction manual for carrying out environmental risk analyses provides a united approach and a common framework for environmental risk assessments. This is based on the best information available. The manual implies standardizations of a series of parameters, input data and partial analyses that are included in the environmental risk analysis. Environmental risk analyses carried out according to the MIRA method will thus be comparable between fields and between companies. In this revision an update of the text in accordance with today's practice for environmental risk analyses and prevailing regulations is emphasized. Moreover, method adjustments for especially protected beach habitats have been introduced, as well as a general method for estimating environmental risk concerning fish. Emphasis has also been put on improving environmental risk analysis' possibilities to contribute to a better management of environmental risk in the companies (ml)

  1. A GPU code for analytic continuation through a sampling method

    Directory of Open Access Journals (Sweden)

    Johan Nordström

    2016-01-01

    Full Text Available We here present a code for performing analytic continuation of fermionic Green’s functions and self-energies as well as bosonic susceptibilities on a graphics processing unit (GPU. The code is based on the sampling method introduced by Mishchenko et al. (2000, and is written for the widely used CUDA platform from NVidia. Detailed scaling tests are presented, for two different GPUs, in order to highlight the advantages of this code with respect to standard CPU computations. Finally, as an example of possible applications, we provide the analytic continuation of model Gaussian functions, as well as more realistic test cases from many-body physics.

  2. Application of an analytical method for the field calculation in superconducting magnets

    International Nuclear Information System (INIS)

    Martinelli, G.; Morini, A.

    1983-01-01

    Superconducting magnets are taking on ever-growing importance due to their increasing prospects of utilization in electrical machines, nuclear fusion, MHD conversion and high-energy physics. These magnets are generally composed of cylindrical or saddle coils, while a ferromagnetic shield is generally situated outside them. This paper uses an analytical method for calculating the magnetic field at every point in a superconducting magnet composed of cylindrical or saddle coils. The method takes into account the real lengths and finite thickness of the coils as well as their radial and axial ferromagnetic shields, if present. The values and distribution of the flux density for some superconducting magnets of high dimensions and high magnetic field, composed of cylindrical or saddle coils, are also given. The results obtained with analytical method are compared with those obtained using numerical methods

  3. Flammable gas safety program. Analytical methods development: FY 1994 progress report

    International Nuclear Information System (INIS)

    Campbell, J.A.; Clauss, S.; Grant, K.; Hoopes, V.; Lerner, B.; Lucke, R.; Mong, G.; Rau, J.; Wahl, K.; Steele, R.

    1994-09-01

    This report describes the status of developing analytical methods to account for the organic components in Hanford waste tanks, with particular focus on tanks assigned to the Flammable Gas Watch List. The methods that have been developed are illustrated by their application to samples obtained from Tank 241-SY-101 (Tank 101-SY)

  4. Application of model-based and knowledge-based measuring methods as analytical redundancy

    International Nuclear Information System (INIS)

    Hampel, R.; Kaestner, W.; Chaker, N.; Vandreier, B.

    1997-01-01

    The safe operation of nuclear power plants requires the application of modern and intelligent methods of signal processing for the normal operation as well as for the management of accident conditions. Such modern and intelligent methods are model-based and knowledge-based ones being founded on analytical knowledge (mathematical models) as well as experiences (fuzzy information). In addition to the existing hardware redundancies analytical redundancies will be established with the help of these modern methods. These analytical redundancies support the operating staff during the decision-making. The design of a hybrid model-based and knowledge-based measuring method will be demonstrated by the example of a fuzzy-supported observer. Within the fuzzy-supported observer a classical linear observer is connected with a fuzzy-supported adaptation of the model matrices of the observer model. This application is realized for the estimation of the non-measurable variables as steam content and mixture level within pressure vessels with water-steam mixture during accidental depressurizations. For this example the existing non-linearities will be classified and the verification of the model will be explained. The advantages of the hybrid method in comparison to the classical model-based measuring methods will be demonstrated by the results of estimation. The consideration of the parameters which have an important influence on the non-linearities requires the inclusion of high-dimensional structures of fuzzy logic within the model-based measuring methods. Therefore methods will be presented which allow the conversion of these high-dimensional structures to two-dimensional structures of fuzzy logic. As an efficient solution of this problem a method based on cascaded fuzzy controllers will be presented. (author). 2 refs, 12 figs, 5 tabs

  5. A functional-analytic method for the study of difference equations

    Directory of Open Access Journals (Sweden)

    Siafarikas Panayiotis D

    2004-01-01

    Full Text Available We will give the generalization of a recently developed functional-analytic method for studying linear and nonlinear, ordinary and partial, difference equations in the and spaces, p∈ℕ, . The method will be illustrated by use of two examples concerning a nonlinear ordinary difference equation known as the Putnam equation, and a linear partial difference equation of three variables describing the discrete Newton law of cooling in three dimensions.

  6. An analytical method for calculating stresses and strains of ATF cladding based on thick walled theory

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Kim, Hak Sung [Hanyang University, Seoul (Korea, Republic of); Kim, Hyo Chan; Yang, Yong Sik; In, Wang kee [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, an analytical method based on thick walled theory has been studied to calculate stress and strain of ATF cladding. In order to prescribe boundary conditions of the analytical method, two algorithms were employed which are called subroutine 'Cladf' and 'Couple' of FRACAS, respectively. To evaluate the developed method, equivalent model using finite element method was established and stress components of the method were compared with those of equivalent FE model. One of promising ATF concepts is the coated cladding, which take advantages such as high melting point, a high neutron economy, and low tritium permeation rate. To evaluate the mechanical behavior and performance of the coated cladding, we need to develop the specified model to simulate the ATF behaviors in the reactor. In particular, the model for simulation of stress and strain for the coated cladding should be developed because the previous model, which is 'FRACAS', is for one body model. The FRACAS module employs the analytical method based on thin walled theory. According to thin-walled theory, radial stress is defined as zero but this assumption is not suitable for ATF cladding because value of the radial stress is not negligible in the case of ATF cladding. Recently, a structural model for multi-layered ceramic cylinders based on thick-walled theory was developed. Also, FE-based numerical simulation such as BISON has been developed to evaluate fuel performance. An analytical method that calculates stress components of ATF cladding was developed in this study. Thick-walled theory was used to derive equations for calculating stress and strain. To solve for these equations, boundary and loading conditions were obtained by subroutine 'Cladf' and 'Couple' and applied to the analytical method. To evaluate the developed method, equivalent FE model was established and its results were compared to those of analytical model. Based on the

  7. Collection of analytes from microneedle patches.

    Science.gov (United States)

    Romanyuk, Andrey V; Zvezdin, Vasiliy N; Samant, Pradnya; Grenader, Mark I; Zemlyanova, Marina; Prausnitz, Mark R

    2014-11-04

    Clinical medicine and public health would benefit from simplified acquisition of biological samples from patients that can be easily obtained at point of care, in the field, and by patients themselves. Microneedle patches are designed to serve this need by collecting dermal interstitial fluid containing biomarkers without the dangers, pain, or expertise needed to collect blood. This study presents novel methods to collect biomarker analytes from microneedle patches for analysis by integration into conventional analytical laboratory microtubes and microplates. Microneedle patches were made out of cross-linked hydrogel composed of poly(methyl vinyl ether-alt-maleic acid) and poly(ethylene glycol) prepared by micromolding. Microneedle patches were shown to swell with water up to 50-fold in volume, depending on degree of polymer cross-linking, and to collect interstitial fluid from the skin of rats. To collect analytes from microneedle patches, the patches were mounted within the cap of microcentrifuge tubes or formed the top of V-bottom multiwell microplates, and fluid was collected in the bottom of the tubes under gentle centrifugation. In another method, microneedle patches were attached to form the bottom of multiwell microplates, thereby enabling in situ analysis. The simplicity of biological sample acquisition using microneedle patches coupled with the simplicity of analyte collection from microneedles patches integrated into conventional analytical equipment could broaden the reach of future screening, diagnosis, and monitoring of biomarkers in healthcare and environmental/workplace settings.

  8. Determination of radium isotopes in environmental samples by gamma spectrometry, liquid scintillation counting and alpha spectrometry: a review of analytical methodology

    International Nuclear Information System (INIS)

    Jia, Guogang; Jia, Jing

    2012-01-01

    Radium (Ra) isotopes are important from the viewpoints of radiation protection and environmental protection. Their high toxicity has stimulated the continuing interest in methodology research for determination of Ra isotopes in various media. In this paper, the three most routinely used analytical techniques for Ra isotope determination in biological and environmental samples, i.e. low-background γ-spectrometry, liquid scintillation counting and α-spectrometry, were reviewed, with emphasis on new methodological developments in sample preparation, preconcentration, separation, purification, source preparation and measurement techniques. The accuracy, selectivity, traceability, applicability and minimum detectable activity (MDA) of the three techniques were discussed. It was concluded that the MDA (0.1 mBq L −1 ) of the α-spectrometry technique coupled with chemical separation is about two orders of magnitude lower than that of low-background HPGe γ-spectrometry and LSC techniques. Therefore, when maximum sensitivity is required, the α-spectrometry technique remains the first choice. - Highlights: ► A review is made for determination of Ra isotopes in environmental samples. ► Gamma spectrometry, LSC and a-spectrometry are the main concerned radiometric approach. ► Sample preparation, preconcentration, separation and source preparation are discussed. ► The methods can analyse air, water, seawater, soil, sediment and foodstuffs samples. ► Some new data obtained recently from our laboratory for Ra method study are included.

  9. Two-dimensional semi-analytic nodal method for multigroup pin power reconstruction

    International Nuclear Information System (INIS)

    Seung Gyou, Baek; Han Gyu, Joo; Un Chul, Lee

    2007-01-01

    A pin power reconstruction method applicable to multigroup problems involving square fuel assemblies is presented. The method is based on a two-dimensional semi-analytic nodal solution which consists of eight exponential terms and 13 polynomial terms. The 13 polynomial terms represent the particular solution obtained under the condition of a 2-dimensional 13 term source expansion. In order to achieve better approximation of the source distribution, the least square fitting method is employed. The 8 exponential terms represent a part of the analytically obtained homogeneous solution and the 8 coefficients are determined by imposing constraints on the 4 surface average currents and 4 corner point fluxes. The surface average currents determined from a transverse-integrated nodal solution are used directly whereas the corner point fluxes are determined during the course of the reconstruction by employing an iterative scheme that would realize the corner point balance condition. The outgoing current based corner point flux determination scheme is newly introduced. The accuracy of the proposed method is demonstrated with the L336C5 benchmark problem. (authors)

  10. Solution of the isotopic depletion equation using decomposition method and analytical solution

    Energy Technology Data Exchange (ETDEWEB)

    Prata, Fabiano S.; Silva, Fernando C.; Martinez, Aquilino S., E-mail: fprata@con.ufrj.br, E-mail: fernando@con.ufrj.br, E-mail: aquilino@lmp.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear

    2011-07-01

    In this paper an analytical calculation of the isotopic depletion equations is proposed, featuring a chain of major isotopes found in a typical PWR reactor. Part of this chain allows feedback reactions of (n,2n) type. The method is based on decoupling the equations describing feedback from the rest of the chain by using the decomposition method, with analytical solutions for the other isotopes present in the chain. The method was implemented in a PWR reactor simulation code, that makes use of the nodal expansion method (NEM) to solve the neutron diffusion equation, describing the spatial distribution of neutron flux inside the reactor core. Because isotopic depletion calculation module is the most computationally intensive process within simulation systems of nuclear reactor core, it is justified to look for a method that is both efficient and fast, with the objective of evaluating a larger number of core configurations in a short amount of time. (author)

  11. Solution of the isotopic depletion equation using decomposition method and analytical solution

    International Nuclear Information System (INIS)

    Prata, Fabiano S.; Silva, Fernando C.; Martinez, Aquilino S.

    2011-01-01

    In this paper an analytical calculation of the isotopic depletion equations is proposed, featuring a chain of major isotopes found in a typical PWR reactor. Part of this chain allows feedback reactions of (n,2n) type. The method is based on decoupling the equations describing feedback from the rest of the chain by using the decomposition method, with analytical solutions for the other isotopes present in the chain. The method was implemented in a PWR reactor simulation code, that makes use of the nodal expansion method (NEM) to solve the neutron diffusion equation, describing the spatial distribution of neutron flux inside the reactor core. Because isotopic depletion calculation module is the most computationally intensive process within simulation systems of nuclear reactor core, it is justified to look for a method that is both efficient and fast, with the objective of evaluating a larger number of core configurations in a short amount of time. (author)

  12. Analytical Method Development for the Determination of Α-Endosulfan and Bifenthrin Pesticide Residues in Tea

    Directory of Open Access Journals (Sweden)

    Dyah Styarini

    2014-03-01

    Full Text Available The development of analytical method for the determination of α-endosulfan and bifenthrin residues in tea has been done. The complex matrices and also the pigment were the challenge in doing quantification of the pesticide residues in tea matrices. In order to get appropriate analysis method for the determination of pesticide residues in tea, the modification was done in the analytical method for the determination of organochlorine multiresidue in non fat matrices: seasoning and spicy that is published by Directorate General of Food Crops, Directorate of Food Plant Protection. The modification was done particularly in clean-up step to remove the interferences from the extract of tea matrices such as the pigment that usually interfere the measurement with Gas Chromatography (GC. The result showed that the MDL value for both analytes were 0.5 ng/g that were much lower than MRLs. The percent recovery obtained from the method was 78.58 and 90.19% for α-endosulfan and bifenthrin, respectively. The precision of the analysis method for both analytes were good since the % RSD values were below than the Horwitz’s value that was 19.18% at spiking level concentration of 300 ng/g.

  13. Analytical Methods for Mycotoxin Detection in Southeast Asian Nations (ASEAN).

    Science.gov (United States)

    Lim, Chee Wei; Chung, Gerald; Chan, Sheot Harn

    2017-10-03

    Aflatoxins B 1 (AFB 1 ) and B₂ (AFB₂) and G 1 and G₂ remain the top mycotoxins routinely analyzed and monitored by Association of Southeast Asian Nations (ASEAN) national laboratories primarily for food safety regulation in the major food commodities, nuts and spices. LC tandem fluorescence detection (LC–fluorescence) represents a current mainstream analytical method, with a progressive migration to a primary method by LC tandem MS (MS/MS) for the next half decade. Annual proficiency testing (PT) is conducted by ASEAN Food Reference Laboratories (AFRLs) for mycotoxin testing as part of capability building in national laboratories, with the scope of PT materials spanning from naturally mycotoxin-contaminated spices and nuts in the early 2010s to the recent contamination of corn flour in 2017 for total aflatoxin assay development. The merits of the mainstream LC–fluorescence method are witnessed by a significant improvement ( P < 0.05) in PT z -score passing rates (≤2) from 11.8 to 79.2% for AFB 1 , 23.5 to 83.3% for AFB₂, and 23.5 to 79.2% for total aflatoxins in the last 5 years. This paper discusses the journey of ASEAN national laboratories in analytical testing through AFRLs, and the progressive collective adoption of a multimycotoxin LC-MS/MS method aided by an isotopic dilution assay as a future primary method for safer food commodities.

  14. Paper-Based Analytical Device for Zinc Ion Quantification in Water Samples with Power-Free Analyte Concentration

    Directory of Open Access Journals (Sweden)

    Hiroko Kudo

    2017-04-01

    Full Text Available Insufficient sensitivity is a general issue of colorimetric paper-based analytical devices (PADs for trace analyte detection, such as metal ions, in environmental water. This paper demonstrates the colorimetric detection of zinc ions (Zn2+ on a paper-based analytical device with an integrated analyte concentration system. Concentration of Zn2+ ions from an enlarged sample volume (1 mL has been achieved with the aid of a colorimetric Zn2+ indicator (Zincon electrostatically immobilized onto a filter paper substrate in combination with highly water-absorbent materials. Analyte concentration as well as sample pretreatment, including pH adjustment and interferent masking, has been elaborated. The resulting device enables colorimetric quantification of Zn2+ in environmental water samples (tap water, river water from a single sample application. The achieved detection limit of 0.53 μM is a significant improvement over that of a commercial colorimetric Zn2+ test paper (9.7 μM, demonstrating the efficiency of the developed analyte concentration system not requiring any equipment.

  15. A new diffusion nodal method based on analytic basis function expansion

    International Nuclear Information System (INIS)

    Noh, J.M.; Cho, N.Z.

    1993-01-01

    The transverse integration procedure commonly used in most advanced nodal methods results in some limitations. The first is that the transverse leakage term that appears in the transverse integration procedure must be appropriately approximated. In most advanced nodal methods, this term is expanded in a quadratic polynomial. The second arises when reconstructing the pinwise flux distribution within a node. The available one-dimensional flux shapes from nodal calculation in each spatial direction cannot be used directly in the flux reconstruction. Finally, the transverse leakage defined for a hexagonal node becomes so complicated as not to be easily handled and contains nonphysical singular terms. In this paper, a new nodal method called the analytic function expansion nodal (AFEN) method is described for both the rectangular geometry and the hexagonal geometry in order to overcome these limitations. This method does not solve the transverse-integrated one-dimensional diffusion equations but instead solves directly the original multidimensional diffusion equation within a node. This is a accomplished by expanding the solution (or the intranodal homogeneous flux distribution) in terms of nonseparable analytic basis functions satisfying the diffusion equation at any point in the node

  16. Recent applications of nuclear analytical methods to the certification of elemental content in NIST standard reference materials

    International Nuclear Information System (INIS)

    Greenberg, R.R.; Zeisler, R.; Mackey, E.A.

    2006-01-01

    Well-characterized, certified reference materials (CRMs) play an essential role in assuring the quality of analytical measurements. NIST has been producing CRMs, currently called NIST Standard Reference Materials (SRMs), to validate analytical measurements for nearly one hundred years. The predominant mode of certifying inorganic constituents in complex-matrix SRMs is through the use of two critically evaluated, independent analytical techniques at NIST. These techniques should have no significant sources of error in common. The use of nuclear analytical methods in combination with one of the chemically based analytical method at NIST eliminates the possibility of any significant, common error source. The inherent characteristics of the various forms of nuclear analytical methods make them extremely valuable for SRM certification. Instrumental NAA is nondestructive, which eliminates the possibility of any dissolution problems, and often provides homogeneity information. Radiochemical NAA typically provides nearly blank-free determinations of some highly important, but difficult elements at very low levels. Prompt-gamma NAA complements INAA, and provides independent determinations of some key elements. In addition, all significant uncertainty components can be evaluated for these techniques, and we believe these methods can meet all the requirements of a primary method of measurement as defined by ISO and the CCQM. NIST has certified several SRMs using INAA and RNAA as primary methods. In addition, NIST has compared measurements by INAA and PGAA with other primary methods as part of the CCQM intercomparisons of national metrology institutes. Some significant SRMs recently certified for inorganic constituents with contributions from the nuclear analytical methods include: Toxic Substances in Urine (SRM 2670a), Lake Superior Fish Tissue (SRM 1946), Air Particulate on Filter Media (SRM 2783), Inorganics in Marine Sediment (SRM 2702), Sediment for Solid Sampling (Small

  17. En introduktion til CARM: The Conversation Analytic Role-Play Method

    DEFF Research Database (Denmark)

    Lange, Simon Bierring

    2014-01-01

    Dette working paper er en introduktion til og kort diskussion af workshopmetoden Conversation Analytic Role-Play Method (CARM), som er en metode udviklet til at afholde workshops på baggrund af resultater fra interaktionsanalyser. Artiklen er den første introduktion til CARM-metoden på dansk, og...

  18. Optimization of offshore wind turbine support structures using analytical gradient-based method

    OpenAIRE

    Chew, Kok Hon; Tai, Kang; Ng, E.Y.K.; Muskulus, Michael

    2015-01-01

    Design optimization of the offshore wind turbine support structure is an expensive task; due to the highly-constrained, non-convex and non-linear nature of the design problem. This report presents an analytical gradient-based method to solve this problem in an efficient and effective way. The design sensitivities of the objective and constraint functions are evaluated analytically while the optimization of the structure is performed, subject to sizing, eigenfrequency, extreme load an...

  19. The analytic nodal method in cylindrical geometry

    International Nuclear Information System (INIS)

    Prinsloo, Rian H.; Tomasevic, Djordje I.

    2008-01-01

    Nodal diffusion methods have been used extensively in nuclear reactor calculations, specifically for their performance advantage, but also for their superior accuracy. More specifically, the Analytic Nodal Method (ANM), utilising the transverse integration principle, has been applied to numerous reactor problems with much success. In this work, a nodal diffusion method is developed for cylindrical geometry. Application of this method to three-dimensional (3D) cylindrical geometry has never been satisfactorily addressed and we propose a solution which entails the use of conformal mapping. A set of 1D-equations with an adjusted, geometrically dependent, inhomogeneous source, is obtained. This work describes the development of the method and associated test code, as well as its application to realistic reactor problems. Numerical results are given for the PBMR-400 MW benchmark problem, as well as for a 'cylindrisized' version of the well-known 3D LWR IAEA benchmark. Results highlight the improved accuracy and performance over finite-difference core solutions and investigate the applicability of nodal methods to 3D PBMR type problems. Results indicate that cylindrical nodal methods definitely have a place within PBMR applications, yielding performance advantage factors of 10 and 20 for 2D and 3D calculations, respectively, and advantage factors of the order of 1000 in the case of the LWR problem

  20. Strategic environmental assessment methodologies--applications within the energy sector

    International Nuclear Information System (INIS)

    Finnveden, Goeran; Nilsson, Maans; Johansson, Jessica; Persson, Aasa; Moberg, Aasa; Carlsson, Tomas

    2003-01-01

    Strategic Environmental Assessment (SEA) is a procedural tool and within the framework of SEA, several different types of analytical tools can be used in the assessment. Several analytical tools are presented and their relation to SEA is discussed including methods for future studies, Life Cycle Assessment, Risk Assessment, Economic Valuation and Multi-Attribute Approaches. A framework for the integration of some analytical tools in the SEA process is suggested. It is noted that the available analytical tools primarily cover some types of environmental impacts related to emissions of pollutants. Tools covering impacts on ecosystems and landscapes are more limited. The relation between application and choice of analytical tools is discussed. It is suggested that SEAs used to support a choice between different alternatives require more quantitative methods, whereas SEAs used to identify critical aspects and suggest mitigation strategies can suffice with more qualitative methods. The possible and desired degree of site-specificity in the assessment can also influence the choice of methods. It is also suggested that values and world views can be of importance for judging whether different types of tools and results are meaningful and useful. Since values and world views differ between different stakeholders, consultation and understanding are important to ensure credibility and relevance

  1. Environmental Measurements Laboratory annual report, calendar year 1980

    International Nuclear Information System (INIS)

    Volchok, H.L.

    1981-05-01

    The 1980 Annual Report is presented as a series of abstracts, organized by broad programmatic headings under the five technical Laboratory Divisions and one Branch. In addition, a short section appears at the end of the report describing the organization, staff, outside activities and our publications and presentations for the year. Research performaed by the Environmental Studies Division is reported under the following categories: high altitude sampling program, deposition and surface air, and the biosphere. Measurement methods research and air quality field studies are reported by the Aerosol Studies Division. The Radiation Physics Division reported research on radiation transport theory, radiation dosimetry, environmental radioactivity, and the assessment of non-nuclear energy technologies. Research in the Analytical Chemistry Division is reported on quality assurance, analytical support of research projects, analytical development for research projects, and programmatic research. The Instrumentation Division reported research on the development of instrumentation in various categories. The Applied Mathematics Branch reported results of programs for aerosol studies, analytical chemistry, environmental studies, and radiation physics

  2. Analytical method for the isotopic characterization of soils

    International Nuclear Information System (INIS)

    Sibello Hernandez, Rita; Cozzella, Maria Letizia; Mariani, Mario

    2014-01-01

    The aim of this work was to develop an analytical method in order to determine the isotopic composition of different elements in soil samples and to determine the existence of contamination. The method used in the digestion of the samples was the EPA 3050B, and some metal concentration were determined including uranium and thorium. For elements with even lower concentrations such as plutonium and radium a treatment after mineralization by EPA, was necessary. The measurement technique used was mass spectrometry with quadrupole and plasma induced associated (ICP-MS). Results of the analysis performed in two laboratories showed a good correspondence. This method allowed to perform the isotopic characterization of studied soils and results showed that the studied soils do not present any local pollution and that the presence of plutonium-239, is due to global failure

  3. Radiochemical methods. Analytical chemistry by open learning

    Energy Technology Data Exchange (ETDEWEB)

    Geary, W.J.; James, A.M. (ed.)

    1986-01-01

    This book presents the analytical uses of radioactive isotopes within the context of radiochemistry as a whole. It is designed for scientists with relatively little background knowledge of the subject. Thus the initial emphasis is on developing the basic concepts of radioactive decay, particularly as they affect the potential usage of radioisotopes. Discussion of the properties of various types of radiation, and of factors such as half-life, is related to practical considerations such as counting and preparation methods, and handling/disposal problems. Practical aspects are then considered in more detail, and the various radioanalytical methods are outlined with particular reference to their applicability. The approach is 'user friendly' and the use of self assessment questions allows the reader to test his/her understanding of individual sections easily. For those who wish to develop their knowledge further, a reading list is provided.

  4. Precision profiles and analytic reliability of radioimmunologic methods

    International Nuclear Information System (INIS)

    Yaneva, Z.; Popova, Yu.

    1991-01-01

    The aim of the present study is to investigate and compare some methods for creation of 'precision profiles' (PP) and to clarify their possibilities for determining the analytical reliability of RIA. Only methods without complicated mathematical calculations has been used. The reproducibility in serums with a concentration of the determinable hormone in the whole range of the calibration curve has been studied. The radioimmunoassay has been performed with TSH-RIA set (ex East Germany), and comparative evaluations - with commercial sets of HOECHST (Germany) and AMERSHAM (GB). Three methods for obtaining the relationship concentration (IU/l) -reproducibility (C.V.,%) are used and a comparison is made of their corresponding profiles: preliminary rough profile, Rodbard-PP and Ekins-PP. It is concluded that the creation of a precision profile is obligatory and the method of its construction does not influence the relationship's course. PP allows to determine concentration range giving stable results which improves the efficiency of the analitical work. 16 refs., 4 figs

  5. Simulation of an Electromagnetic Acoustic Transducer Array by Using Analytical Method and FDTD

    Directory of Open Access Journals (Sweden)

    Yuedong Xie

    2016-01-01

    Full Text Available Previously, we developed a method based on FEM and FDTD for the study of an Electromagnetic Acoustic Transducer Array (EMAT. This paper presents a new analytical solution to the eddy current problem for the meander coil used in an EMAT, which is adapted from the classic Deeds and Dodd solution originally intended for circular coils. The analytical solution resulting from this novel adaptation exploits the large radius extrapolation and shows several advantages over the finite element method (FEM, especially in the higher frequency regime. The calculated Lorentz force density from the analytical EM solver is then coupled to the ultrasonic simulations, which exploit the finite-difference time-domain (FDTD method to describe the propagation of ultrasound waves, in particular for Rayleigh waves. Radiation pattern obtained with Hilbert transform on time-domain waveforms is proposed to characterise the sensor in terms of its beam directivity and field distribution along the steering angle, which can produce performance parameters for an EMAT array, facilitating the optimum design of such sensors.

  6. Comparison of Three Analytical Methods for Separation of Mineral and Chelated Fraction from an Adulterated Zn-EDTA Fertilizer

    International Nuclear Information System (INIS)

    Khan, M.S.; Qazi, M.A.; Khan, N.A.; Mian, S.M.; Ahmed, N.; Ahmed, N.

    2013-01-01

    Summary: Different analytical procedures are being employed in the world to quantify the chelated portion in a Zn-EDTA fertilizer. Agriculture Department, Government of the Punjab is following Shahid's analytical method in this regard. This method is based on Ion-chromatography (IC) that separates the mineral zinc (Zn) from an adulterated Zn-EDTA fertilizer sample i.e. mixture of mineral and chelated Zn fractions. To find out its effectiveness and suitability, this comparative study was carried out by analyzing adulterated, non-adulterated Zn-EDTA standard and Zn-EDTA samples taken from market in thrice following three methods namely Shahid's (IC) analytical method, Atomic Absorption Spectrophotometric (AAS) method based on the principle of precipitating the mineral Zn fraction at high pH value by using alkali solution of suitable concentration and analysis of filtrate containing only chelated fraction and Association of Official Analytical Chemists (AOAC) method FM-841 respectively. Adulterated Zn-EDTA samples were prepared by mixing of known quantity of mineral Zn with chelated Zn-EDTA standard. The results showed that Shahid's analytical method and AAS method, both successfully estimated the chelated fraction. The AOAC FM-841 method was insensitive to put a ceiling on the mineral fraction hence did not furnish the reliable results. The Shahid's analytical method was selected being equallyeffective to produce reliable results both for solid and liquid Zn-EDTA samples. The AAS method was comparable in only liquid samples. (author)

  7. Analytical chemistry in semiconductor manufacturing: Techniques, role of nuclear methods and need for quality control

    International Nuclear Information System (INIS)

    1989-06-01

    This report is the result of a consultants meeting held in Gaithersburg, USA, 2-3 October 1987. The meeting was hosted by the National Bureau of Standards and Technology, and it was attended by 18 participants from Denmark, Finland, India, Japan, Norway, People's Republic of China and the USA. The purpose of the meeting was to assess the present status of analytical chemistry in semiconductor manufacturing, the role of nuclear analytical methods and the need for internationally organized quality control of the chemical analysis. The report contains the three presentations in full and a summary report of the discussions. Thus, it gives an overview of the need of analytical chemistry in manufacturing of silicon based devices, the use of nuclear analytical methods, and discusses the need for quality control. Refs, figs and tabs

  8. Survey of analytical methods for environmental monitoring of krypton-85

    International Nuclear Information System (INIS)

    Jaquish, R.E.; Moghissi, A.A.

    1973-01-01

    Numerous methods have been developed for measuring krypton-85 in air as krypton ultimately accumulates in air once it is released into the environment. However, krypton-85 can be present in other media such as natural gas from wells stimulated with nuclear devices or in water when krypton-85 is used for aeration studies. Methods for the measurement of ambient levels of krypton-85 require a concentration of krypton from a large air sample of one m 3 or more. If elevated levels are to be measured, carrier krypton may be used provided the contamination of atmospheric krypton with krypton-85 does not interfere with the measurement. In certain cases, such as in the vicinity of nuclear fuel processing plants, direct measurement techniques may be used. A variety of techniques are employed for krypton-85 counting. At low levels, internal gas counting or organic scintillation is used to measure the beta emission of this radionuclide. At higher levels the gamma emission of krypton-85 may be measured using scintillation or solid state gamma spectroscopic methods. Techniques for collection of the sample, concentration of krypton, and radioactivity measurement of krypton-85 are discussed and various processes are critically evaluated and compared

  9. Comparative study of environmental impact assessment methods ...

    African Journals Online (AJOL)

    This study aims to introduce and systematically investigate the environmental issues during important decision-making stages. Meanwhile, impacts of development on the environmental components will be also analyzed. This research studies various methods of predicting the environmental changes and determining the ...

  10. Detection of food irradiation - two analytical methods

    International Nuclear Information System (INIS)

    1994-01-01

    This publication summarizes the activities of Nordic countries in the field of detection of irradiated food. The National Food Agency of Denmark has coordinated the project. The two analytical methods investigated were: the gas-chromatographic determination of the hydrocarbon/lipid ratio in irradiated chicken meat, and a bioassay based on microelectrophoresis of DNA from single cells. Also a method for determination of o-tyrosine in the irradiated and non-irradiated chicken meat has been tested. The first method based on radiolytical changes in fatty acids, contained in chicken meat, has been tested and compared in the four Nordic countries. Four major hydrocarbons (C16:2, C16:3, C17:1 and C17:2) have been determined and reasonable agreement was observed between the dose level and hydrocarbons concentration. Results of a bioassay, where strand breaks of DNA are demonstrated by microelectrophoresis of single cells, prove a correlation between the dose levels and the pattern of DNA fragments migration. The hydrocarbon method can be applied to detect other irradiated, fat-containing foods, while the DNA method can be used for some animal and some vegetable foods as well.Both methods allow to determine the fact of food irradiation beyond any doubt, thus making them suitable for food control analysis. The detailed determination protocols are given. (EG)

  11. The Methodical Instrumentarium for Analytical Monitoring of Markets for High-Tech Products

    Directory of Open Access Journals (Sweden)

    Mikaelian Suren G.

    2017-10-01

    Full Text Available The article is aimed at clarifying the essential characteristics of high-tech products and specifying the features of analytical monitoring of markets for high-tech products. The conceptual approaches to interpretation of the essence of high-tech products as a basic concept in the categorical apparatus for researching the systemic and complex processes of technological development have been clarified. The most efficient instruments for assessing innovation processes in the high-tech sphere have been systematized. The methodical instrumentarium for analytical monitoring of the markets for high-tech products has been clarified. The terminology of a high-tech product has been clarified in order to formulate the methodical instrumentarium for analytical monitoring of market for high-tech products. It has been determined that «high-tech products» are the original basic concept in the categorical apparatus for researching the systemic and complex processes of the high-tech market that needs to be concretized. Conceptual approaches to the essence of high-tech products have been systematized.

  12. Rational Selection, Criticality Assessment, and Tiering of Quality Attributes and Test Methods for Analytical Similarity Evaluation of Biosimilars.

    Science.gov (United States)

    Vandekerckhove, Kristof; Seidl, Andreas; Gutka, Hiten; Kumar, Manish; Gratzl, Gyöngyi; Keire, David; Coffey, Todd; Kuehne, Henriette

    2018-05-10

    Leading regulatory agencies recommend biosimilar assessment to proceed in a stepwise fashion, starting with a detailed analytical comparison of the structural and functional properties of the proposed biosimilar and reference product. The degree of analytical similarity determines the degree of residual uncertainty that must be addressed through downstream in vivo studies. Substantive evidence of similarity from comprehensive analytical testing may justify a targeted clinical development plan, and thus enable a shorter path to licensing. The importance of a careful design of the analytical similarity study program therefore should not be underestimated. Designing a state-of-the-art analytical similarity study meeting current regulatory requirements in regions such as the USA and EU requires a methodical approach, consisting of specific steps that far precede the work on the actual analytical study protocol. This white paper discusses scientific and methodological considerations on the process of attribute and test method selection, criticality assessment, and subsequent assignment of analytical measures to US FDA's three tiers of analytical similarity assessment. Case examples of selection of critical quality attributes and analytical methods for similarity exercises are provided to illustrate the practical implementation of the principles discussed.

  13. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  14. Methods for the calculation of uncertainty in analytical chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Sohn, S. C.; Park, Y. J.; Park, K. K.; Jee, K. Y.; Joe, K. S.; Kim, W. H

    2000-07-01

    This report describes the statistical rules for evaluating and expressing uncertainty in analytical chemistry. The procedures for the evaluation of uncertainty in chemical analysis are illustrated by worked examples. This report, in particular, gives guidance on how uncertainty can be estimated from various chemical analyses. This report can be also used for planning the experiments which will provide the information required to obtain an estimate of uncertainty for the method.

  15. UNOCAL Parachute Creek Shale Oil Program. Environmental Monitoring Plan - supplemental environmental. Volume 1. Trip 2 report. Rept. for 1988-90

    International Nuclear Information System (INIS)

    1991-01-01

    The Energy Security Act of 1980 established a program to provide financial assistance to private industry in the construction and operation of commercial-scale synthetic fuels plants. The Parachute Creek Shale Oil Program is one of four projects awarded financial assistance. The Program agreed to comply with existing environmental monitoring regulations and to develop an Environmental Monitoring Plan (EMP) incorporating supplemental monitoring in the areas of water, air, solid waste, and worker health and safety during the period 1985-1992. These activities are described in a series of quarterly and annual reports. The report contains results of three years of supplemental environmental sampling (Trial Trip, 1988; Trip 1, 1989; and Trip 2, 1990); Trip 2 sampling and analytical methods; quality assurance and quality control procedures; sampling and analytical methods; and corrected data from 1988 and 1989 gas and particulate concentrations

  16. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages

    Science.gov (United States)

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production. PMID:25751122

  17. Environmental Chemistry Methods (ECM) Index - N

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with N as the first character.

  18. Environmental Chemistry Methods (ECM) Index - K

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with K as the first character.

  19. Environmental Chemistry Methods (ECM) Index - M

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with M as the first character.

  20. Environmental Chemistry Methods (ECM) Index - R

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with R as the first character.

  1. Environmental Chemistry Methods (ECM) Index - G

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with G as the first character.

  2. Environmental Chemistry Methods (ECM) Index - O

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with O as the first character.

  3. Environmental Chemistry Methods (ECM) Index - S

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with S as the first character.

  4. Environmental Chemistry Methods (ECM) Index - B

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with B as the first character.

  5. Environmental Chemistry Methods (ECM) Index - C

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with C as the first character.

  6. Environmental Chemistry Methods (ECM) Index - F

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with F as the first character.

  7. Environmental Chemistry Methods (ECM) Index - P

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with P as the first character.

  8. Environmental Chemistry Methods (ECM) Index - L

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with L as the first character.

  9. Environmental Chemistry Methods (ECM) Index - H

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with H as the first character.

  10. Environmental Chemistry Methods (ECM) Index - I

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with I as the first character.

  11. Environmental Chemistry Methods (ECM) Index - Z

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with Z as the first character.

  12. Environmental Chemistry Methods (ECM) Index - A

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with A as the first character.

  13. Environmental Chemistry Methods (ECM) Index - E

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with E as the first character.

  14. Environmental Chemistry Methods (ECM) Index - T

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with T as the first character.

  15. Environmental Chemistry Methods (ECM) Index - D

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with D as the first character.

  16. Environmental Chemistry Methods (ECM) Index - Q

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with Q as the first character.

  17. Development of a low-cost method of analysis for the qualitative and quantitative analysis of butyltins in environmental samples.

    Science.gov (United States)

    Bangkedphol, Sornnarin; Keenan, Helen E; Davidson, Christine; Sakultantimetha, Arthit; Songsasen, Apisit

    2008-12-01

    Most analytical methods for butyltins are based on high resolution techniques with complicated sample preparation. For this study, a simple application of an analytical method was developed using High Performance Liquid Chromatography (HPLC) with UV detection. The developed method was studied to determine tributyltin (TBT), dibutyltin (DBT) and monobutyltin (MBT) in sediment and water samples. The separation was performed in isocratic mode on an ultra cyanopropyl column with a mobile phase of hexane containing 5% THF and 0.03% acetic acid. This method was confirmed using standard GC/MS techniques and verified by statistical paired t-test method. Under the experimental conditions used, the limit of detection (LOD) of TBT and DBT were 0.70 and 0.50 microg/mL, respectively. The optimised extraction method for butyltins in water and sediment samples involved using hexane containing 0.05-0.5% tropolone and 0.2% sodium chloride in water at pH 1.7. The quantitative extraction of butyltin compounds in a certified reference material (BCR-646) and naturally contaminated samples was achieved with recoveries ranging from 95 to 108% and at %RSD 0.02-1.00%. This HPLC method and optimum extraction conditions were used to determine the contamination level of butyltins in environmental samples collected from the Forth and Clyde canal, Scotland, UK. The values obtained severely exceeded the Environmental Quality Standard (EQS) values. Although high resolution methods are utilised extensively for this type of research, the developed method is cheaper in both terms of equipment and running costs, faster in analysis time and has comparable detection limits to the alternative methods. This is advantageous not just as a confirmatory technique but also to enable further research in this field.

  18. Life cycle assessment as an analytical tool in strategic environmental assessment. Lessons learned from a case study on municipal energy planning in Sweden

    International Nuclear Information System (INIS)

    Björklund, Anna

    2012-01-01

    Life cycle assessment (LCA) is explored as an analytical tool in strategic environmental assessment (SEA), illustrated by case where a previously developed SEA process was applied to municipal energy planning in Sweden. The process integrated decision-making tools for scenario planning, public participation and environmental assessment. This article describes the use of LCA for environmental assessment in this context, with focus on methodology and practical experiences. While LCA provides a systematic framework for the environmental assessment and a wider systems perspective than what is required in SEA, LCA cannot address all aspects of environmental impact required, and therefore needs to be complemented by other tools. The integration of LCA with tools for public participation and scenario planning posed certain methodological challenges, but provided an innovative approach to designing the scope of the environmental assessment and defining and assessing alternatives. - Research highlights: ► LCA was explored as analytical tool in an SEA process of municipal energy planning. ► The process also integrated LCA with scenario planning and public participation. ► Benefits of using LCA were a systematic framework and wider systems perspective. ► Integration of tools required some methodological challenges to be solved. ► This proved an innovative approach to define alternatives and scope of assessment.

  19. No Impact of the Analytical Method Used for Determining Cystatin C on Estimating Glomerular Filtration Rate in Children.

    Science.gov (United States)

    Alberer, Martin; Hoefele, Julia; Benz, Marcus R; Bökenkamp, Arend; Weber, Lutz T

    2017-01-01

    Measurement of inulin clearance is considered to be the gold standard for determining kidney function in children, but this method is time consuming and expensive. The glomerular filtration rate (GFR) is on the other hand easier to calculate by using various creatinine- and/or cystatin C (Cys C)-based formulas. However, for the determination of serum creatinine (Scr) and Cys C, different and non-interchangeable analytical methods exist. Given the fact that different analytical methods for the determination of creatinine and Cys C were used in order to validate existing GFR formulas, clinicians should be aware of the type used in their local laboratory. In this study, we compared GFR results calculated on the basis of different GFR formulas and either used Scr and Cys C values as determined by the analytical method originally employed for validation or values obtained by an alternative analytical method to evaluate any possible effects on the performance. Cys C values determined by means of an immunoturbidimetric assay were used for calculating the GFR using equations in which this analytical method had originally been used for validation. Additionally, these same values were then used in other GFR formulas that had originally been validated using a nephelometric immunoassay for determining Cys C. The effect of using either the compatible or the possibly incompatible analytical method for determining Cys C in the calculation of GFR was assessed in comparison with the GFR measured by creatinine clearance (CrCl). Unexpectedly, using GFR equations that employed Cys C values derived from a possibly incompatible analytical method did not result in a significant difference concerning the classification of patients as having normal or reduced GFR compared to the classification obtained on the basis of CrCl. Sensitivity and specificity were adequate. On the other hand, formulas using Cys C values derived from a compatible analytical method partly showed insufficient

  20. A new colorimetric chemosensors for Cu{sup 2+} and Cd{sup 2+} ions detection: Application in environmental water samples and analytical method validation

    Energy Technology Data Exchange (ETDEWEB)

    Tekuri, Venkatadri; Trivedi, Darshak R., E-mail: darshak_rtrivedi@yahoo.co.in

    2017-06-15

    A new heterocyclic thiophene-2-caboxylic acid hydrazide based chemosensor R1 to R4 were designed, synthesized and characterized by various spectroscopic techniques like FT-IR, UV-Vis, {sup 1}H NMR, {sup 13}C NMR, Mass and SC-XRD. The chemosensor R3 showed a significant color change from colorless to yellow in the presence of Cu{sup 2+} ions and chemosensor R4 showed a significant color change from colorless to yellow in the presence of Cd{sup 2+} ions over the other tested cations such as Cr{sup 3+}, Mn{sup 2+}, Fe{sup 2+}, Fe{sup 3+}, Co{sup 2+}, Ni{sup 2+}, Zn{sup 2+}, Ag{sup 2+}, Al{sup 3+}, Pb{sup 2+}, Hg{sup 2+}, K{sup +}, Ca{sup 2+} and Mg{sup 2+}. The high selective and sensitivity of R3 towards Cu{sup 2+} and R4 towards Cd{sup 2+} ions was confirmed by UV-Vis spectroscopic study. The R3 showed a red shift in the presence of Cu{sup 2+} ions by Δλ{sub max} 67 nm and R4 showed a red shift in the presence of Cd{sup 2+} ions by Δλ{sub max} 105 nm in the absorption spectrum. The binding stoichiometric ratio of the complex between R3 - Cu{sup 2+} and R4 - Cd{sup 2+} ions have been found to be 1:1 using the B-H plot. Under optimized experimental conditions, the R3 and R4 exhibits a dynamic linear absorption response range, from 0 to 50 μM for Cu{sup 2+} ions and 0 to 30 μM for Cd{sup 2+} ions, with the detection limit of 2.8 × 10{sup −6} M for Cu{sup 2+} and 2.0 × 10{sup −7} M for Cd{sup 2+} ions. The proposed analytical method for the quantitative determination of Cu{sup 2+} and Cd{sup 2+} ions was validated and successfully applied for the environmental samples with good precision and accuracy. - Highlights: • Detection of Cu{sup 2+} and Cd{sup 2+} ions has gained significance by virtue of its key role in biological and environmental science. • The R3 and R4 showed instantaneous color change from colorless to yellow in the presence of Cu{sup 2+} and Cd{sup 2+} ions respectively. • The proposed detection methods were validated and

  1. Safety and Waste Management for SAM Chemistry Methods

    Science.gov (United States)

    The General Safety and Waste Management page offers section-specific safety and waste management details for the chemical analytes included in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  2. Safety and Waste Management for SAM Radiochemical Methods

    Science.gov (United States)

    The General Safety and Waste Management page offers section-specific safety and waste management details for the radiochemical analytes included in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  3. Fault feature analysis of cracked gear based on LOD and analytical-FE method

    Science.gov (United States)

    Wu, Jiateng; Yang, Yu; Yang, Xingkai; Cheng, Junsheng

    2018-01-01

    At present, there are two main ideas for gear fault diagnosis. One is the model-based gear dynamic analysis; the other is signal-based gear vibration diagnosis. In this paper, a method for fault feature analysis of gear crack is presented, which combines the advantages of dynamic modeling and signal processing. Firstly, a new time-frequency analysis method called local oscillatory-characteristic decomposition (LOD) is proposed, which has the attractive feature of extracting fault characteristic efficiently and accurately. Secondly, an analytical-finite element (analytical-FE) method which is called assist-stress intensity factor (assist-SIF) gear contact model, is put forward to calculate the time-varying mesh stiffness (TVMS) under different crack states. Based on the dynamic model of the gear system with 6 degrees of freedom, the dynamic simulation response was obtained for different tooth crack depths. For the dynamic model, the corresponding relation between the characteristic parameters and the degree of the tooth crack is established under a specific condition. On the basis of the methods mentioned above, a novel gear tooth root crack diagnosis method which combines the LOD with the analytical-FE is proposed. Furthermore, empirical mode decomposition (EMD) and ensemble empirical mode decomposition (EEMD) are contrasted with the LOD by gear crack fault vibration signals. The analysis results indicate that the proposed method performs effectively and feasibility for the tooth crack stiffness calculation and the gear tooth crack fault diagnosis.

  4. Descriptive and analytic epidemiology. Bridges to cancer control

    International Nuclear Information System (INIS)

    Mettlin, C.

    1988-01-01

    Epidemiology serves as a bridge between basic science and cancer control. The two major orientations of epidemiology are descriptive and analytic. The former is useful in assessing the scope and dimensions of the cancer problem and the latter is used to assess environmental and lifestyle sources of cancer risk. A recent development in descriptive epidemiology is the use of functional measures of disease such as lost life expectancy. In analytical epidemiology, there is new or renewed interest in several lifestyle factors including diet and exercise as well as environmental factors such as involuntary tobacco exposure and radon in dwellings. Review of the evidence should consider the strengths and weaknesses of different research procedures. Each method is inconclusive by itself but, the different research designs of epidemiology collectively may represent a hierarchy of proof. Although the roles of many factors remain to be defined, the aggregate epidemiologic data continue to demonstrate the special importance of personal behavior and lifestyle in affecting cancer risk

  5. Development of analytical techniques in support of waste and effluent characterization

    International Nuclear Information System (INIS)

    Reed, W.J.

    1991-01-01

    The Analytical Services Group within Sellafield Technical Department has been established for >40 yr and employs >150 analysts. The group operates >400 analytical methods across a wide range of techniques and has a yearly workload of ∼250,000 determinations. The group operates under a quality system based on statistical process control that has achieved national recognition through the accreditation of its mass spectrometry and radiochemical services to the standard of national testing laboratories. The group offers services ranging from the characterization of highly active wastes to trace elemental and radiochemical measurements in environmental, biological, and effluent streams. The group has vast experience in the management of analytical services to tight time scales and has pioneered developments not only in analytical instrumentation, but also in the adaptation of equipment to radioactive environments and the design of dedicated analytical facilities

  6. An Analytical Method for the Abel Inversion of Asymmetrical Gaussian Profiles

    International Nuclear Information System (INIS)

    Xu Guosheng; Wan Baonian

    2007-01-01

    An analytical algorithm for fast calculation of the Abel inversion for density profile measurement in tokamak is developed. Based upon the assumptions that the particle source is negligibly small in the plasma core region, density profiles can be approximated by an asymmetrical Gaussian distribution controlled only by one parameter V 0 /D and V 0 /D is constant along the radial direction, the analytical algorithm is presented and examined against a testing profile. The validity is confirmed by benchmark with the standard Abel inversion method and the theoretical profile. The scope of application as well as the error analysis is also discussed in detail

  7. Analytical methods used at IPR (Instituto de Pesquisas Radioativas - Minas Gerais, Brazil)

    International Nuclear Information System (INIS)

    Murta, C.C.

    The analytical methods available at IPR (MG-Brazil) for the routine determination of uranium are described. These methods are: gravimetric analysis; fluorescence spectroscopy, voltametry, polarography, absorption spectroscopy, beta-and gamma-radiometric analysis, gamma spectroscopy, activation analysis, X-rays fluorescence analysis and delayed neutron analysis. Some additional methods for the study of mineral ores, such as X-rays diffractometry, emmission spectroscopy, thermal analysis, etc, are also discussed [pt

  8. 3D analytical method for the external dynamics of ship collisions and investigation of the coefficient of restitution

    Directory of Open Access Journals (Sweden)

    LIU Junfeng

    2017-03-01

    Full Text Available The analytical method for predicting the dynamic responses of a ship in a collision scenario features speed and accuracy,and the external dynamics constitute an important part. A 3D simplified analytical method is implemented by MATLAB and used to calculate the energy dissipation of ship-ship collisions. The results obtained by the proposed method are then compared with those of a 2D simplified analytical method. The total dissipated energy can be obtained through the proposed analytical method, and the influence of the collision heights,angles and locations on the dissipated energy is discussed on that basis. Furthermore,the effects of restitution on the conservative coefficients and the effects of conservative coefficients on energy dissipation are discussed. It is concluded that the proposed 3D analysis yields a lesser energy dissipation than that of the 2D analysis,and the collision height has a significant influence on the dissipated energy. In using the proposed simplified method,it is not safe to simplify the conservative coefficient as zero when the collision angle is greater than 90 degrees. In the future research, to get more accurate energy dissipation, it is a good way to adopt the 3D simplified analytical method instead of the 2D method.

  9. Manual of analytical methods for the Environmental Health Laboratory

    International Nuclear Information System (INIS)

    Gray, C.E.

    1975-06-01

    The manual contains four sections: absorption spectrophotometry; general radiochemical procedures; instrumental analysis; and calibration of field instruments. Included in the individual analyses using absorption spectrophotometry is one for total iodine in oil. Radiochemical procedures are given for: actinides in urine and water; 137 Cs in soil and vegetation; 137 Cs in soil, urine, vegetation, and water; enriched uranium in urine; gross beta activity in soil, urine, vegetation, and water; plutonium in urine and soil; 210 Po in urine and water; 24 Na in air, blood, urine, and water; 90 Sr in soil, vegetation, and water; tritium in urine, water, and on swipes; and total uranium on fallout trays and in soil, urine, and water. Among the individual instrumental analyses is a spectrographic method for determining beryllium in air samples and swipes. (U.S.)

  10. A review of analytical procedures for the simultaneous determination of medically important veterinary antibiotics in environmental water: Sample preparation, liquid chromatography, and mass spectrometry.

    Science.gov (United States)

    Kim, Chansik; Ryu, Hong-Duck; Chung, Eu Gene; Kim, Yongseok; Lee, Jae-Kwan

    2018-07-01

    Medically important (MI) antibiotics are defined by the United States Food and Drug Administration as drugs containing certain active antimicrobial ingredients that are used for the treatment of human diseases or enteric pathogens causing food-borne diseases. The presence of MI antibiotic residues in environmental water is a major concern for both aquatic ecosystems and public health, particularly because of their potential to contribute to the development of antimicrobial-resistant microorganisms. In this article, we present a review of global trends in the sales of veterinary MI antibiotics and the analytical methodologies used for the simultaneous determination of antibiotic residues in environmental water. According to recently published government reports, sales volumes have increased steadily, despite many countries having adopted strategies for reducing the consumption of antibiotics. Global attention needs to be directed urgently at establishing new management strategies for reducing the use of MI antimicrobial products in the livestock industry. The development of standardized analytical methods for the detection of multiple residues is required to monitor and understand the fate of antibiotics in the environment. Simultaneous analyses of antibiotics have mostly been conducted using high-performance liquid chromatography-tandem mass spectrometry with a solid-phase extraction (SPE) pretreatment step. Currently, on-line SPE protocols are used for the rapid and sensitive detection of antibiotics in water samples. On-line detection protocols must be established for the monitoring and screening of unknown metabolites and transformation products of antibiotics in environmental water. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. DEVELOPMENT OF ANALYTICAL METHODS FOR THE QUANTIFICATION OF THE CHEMICAL FORMS OF MERCURY AND OTHER TARGET POLLUTANTS IN COAL-FIRED BOILER FLUE GAS

    Energy Technology Data Exchange (ETDEWEB)

    Terence J. McManus, Ph.D.

    1999-06-30

    . (ATS) as a secondary DOE contractor on this project, assessed the sampling and analytical plans and the emission reports of the five primary contractors to determine how successful the contractors were in satisfying their defined objectives. ATS identified difficulties and inconsistencies in a number of sampling and analytical methodologies in these studies. In particular there was uncertainty as to the validity of the sampling and analytical methods used to differentiate the chemical forms of mercury observed in coal flue gas. Considering the differences in the mercury species with regard to human toxicity, the rate of transport through the ecosystem and the design variations in possible emission control schemes, DOE sought an accurate and reliable means to identify and quantify the various mercury compounds emitted by coal-fired utility boilers. ATS, as a contractor for DOE, completed both bench- and pilot-scale studies on various mercury speciation methods. The final validation of the modified Ontario-Hydro Method, its acceptance by DOE and submission of the method for adoption by ASTM was a direct result of these studies carried out in collaboration with the University of North Dakota's Energy and Environmental Research Center (UNDEERC). This report presents the results from studies carried out at ATS in the development of analytical methods to identify and quantify various chemical species, particularly those of mercury, in coal derived flue gas. Laboratory- and pilot-scale studies, not only on mercury species, but also on other inorganics and organics present in coal combustion flue gas are reported.

  12. The chemical speciation and analysis of trace elements in sediment with Neutron Activation Analytical method(NAA) and atomic mass spectrometry

    International Nuclear Information System (INIS)

    Nam, Sang-Ho; Kim, Jae-Jin; Chung, Yong-Sam; Kim, Sun-Ha

    2003-01-01

    In this research, first of all, the analytical methods for the determination of major elements in sediment have been developed with ICP-MS (Inductively Coupled Plasma Mass Spectrometry). The analytical results of major elements (Al, Ca, K, Fe, Mg) with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA (Neutron Activation Analysis). NAA were a little superior to ICP-MS for the determination of major elements in sediment as a non-destructive trace analytical trace analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) have been also developed with ICP-MS. The analytical results by standard calibration curve with ICP-MS were not accurate due to the matrix interferences. Thus, the internal standard method was applied, then the analytical results for minor elements with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments. Accordingly, the NAA will plan an important role in analysis of environment sample with complex matrix. ICP-MS also will play an important role because it has a great capability for the determination of Pb that could not be determined by NAA

  13. Optimization of analytical techniques to characterize antibiotics in aquatic systems

    International Nuclear Information System (INIS)

    Al Mokh, S.

    2013-01-01

    Antibiotics are considered as pollutants when they are present in aquatic ecosystems, ultimate receptacles of anthropogenic substances. These compounds are studied as their persistence in the environment or their effects on natural organisms. Numerous efforts have been made worldwide to assess the environmental quality of different water resources for the survival of aquatic species, but also for human consumption and health risk related. Towards goal, the optimization of analytical techniques for these compounds in aquatic systems remains a necessity. Our objective is to develop extraction and detection methods for 12 molecules of aminoglycosides and colistin in sewage treatment plants and hospitals waters. The lack of analytical methods for analysis of these compounds and the deficiency of studies for their detection in water is the reason for their study. Solid Phase Extraction (SPE) in classic mode (offline) or online followed by Liquid Chromatography analysis coupled with Mass Spectrometry (LC/MS/MS) is the most method commonly used for this type of analysis. The parameters are optimized and validated to ensure the best conditions for the environmental analysis. This technique was applied to real samples of wastewater treatment plants in Bordeaux and Lebanon. (author)

  14. Contextual and Analytic Qualities of Research Methods Exemplified in Research on Teaching

    Science.gov (United States)

    Svensson, Lennart; Doumas, Kyriaki

    2013-01-01

    The aim of the present article is to discuss contextual and analytic qualities of research methods. The arguments are specified in relation to research on teaching. A specific investigation is used as an example to illustrate the general methodological approach. It is argued that research methods should be carefully grounded in an understanding of…

  15. Application of the invariant embedding method to analytically solvable transport problems

    Energy Technology Data Exchange (ETDEWEB)

    Wahlberg, Malin

    2005-05-01

    The applicability and performance of the invariant embedding method for calculating various transport quantities is investigated in this thesis. The invariant embedding method is a technique to calculate the reflected or transmitted fluxes in homogeneous half-spaces and slabs, without the need for solving for the flux inside the medium. In return, the embedding equations become non-linear, and in practical cases they need to be solved by numerical methods. There are, however, fast and effective iterative methods available for this purpose. The objective of this thesis is to investigate the performance of these iterative methods in model problems, in which also an exact analytical solution can be obtained. Some of these analytical solutions are also new, hence their derivation constitutes a part of the thesis work. The cases investigated in the thesis all concern the calculation of reflected fluxes from half-spaces. The first problem treated was the calculation of the energy spectrum of reflected (sputtered) particles from a multiplying medium, where the multiplication arises from recoil production (i.e. like binary fission), when bombarded by o flux of monoenergetic particles of the same type. Both constant cross sections and energy dependent cross sections with a power law dependence were used in the calculations. The second class of problems concerned the calculation of the path length distribution of reflected particles from a medium without multiplication. It is an interesting new observation that the distribution of the path length travelled in the medium before reflection can be calculated with invariant embedding methods, which actually do not solve the flux distribution in the medium. We have tested the accuracy and the convergence properties of the embedding method also for this case. Finally, very recently a theory of connecting the infinite and half-space medium solutions by embedding-like integral equations was developed and reported in the literature

  16. Application of the invariant embedding method to analytically solvable transport problems

    International Nuclear Information System (INIS)

    Wahlberg, Malin

    2005-05-01

    The applicability and performance of the invariant embedding method for calculating various transport quantities is investigated in this thesis. The invariant embedding method is a technique to calculate the reflected or transmitted fluxes in homogeneous half-spaces and slabs, without the need for solving for the flux inside the medium. In return, the embedding equations become non-linear, and in practical cases they need to be solved by numerical methods. There are, however, fast and effective iterative methods available for this purpose. The objective of this thesis is to investigate the performance of these iterative methods in model problems, in which also an exact analytical solution can be obtained. Some of these analytical solutions are also new, hence their derivation constitutes a part of the thesis work. The cases investigated in the thesis all concern the calculation of reflected fluxes from half-spaces. The first problem treated was the calculation of the energy spectrum of reflected (sputtered) particles from a multiplying medium, where the multiplication arises from recoil production (i.e. like binary fission), when bombarded by o flux of monoenergetic particles of the same type. Both constant cross sections and energy dependent cross sections with a power law dependence were used in the calculations. The second class of problems concerned the calculation of the path length distribution of reflected particles from a medium without multiplication. It is an interesting new observation that the distribution of the path length travelled in the medium before reflection can be calculated with invariant embedding methods, which actually do not solve the flux distribution in the medium. We have tested the accuracy and the convergence properties of the embedding method also for this case. Finally, very recently a theory of connecting the infinite and half-space medium solutions by embedding-like integral equations was developed and reported in the literature

  17. Comparison of three analytical methods for the determination of trace elements in whole blood

    International Nuclear Information System (INIS)

    Ward, N.I.; Stephens, R.; Ryan, D.E.

    1979-01-01

    Three different analytical techniques were compared in a study of the role of trace elements in multiple sclerosis. Data for eight elements (Cd, Co, Cr, Cu, Mg, Mn, Pb, Zn) from neutron activation, flame atomic absorption and electrothermal atomic absorption methods were compared and evaluated statistically. No difference (probability less than 0.001) was observed in the elemental values obtained. Comparison of data between suitably different analytical methods gives increased confidence in the results obtained and is of particular value when standard reference materials are not available. (Auth.)

  18. GenoSets: visual analytic methods for comparative genomics.

    Directory of Open Access Journals (Sweden)

    Aurora A Cain

    Full Text Available Many important questions in biology are, fundamentally, comparative, and this extends to our analysis of a growing number of sequenced genomes. Existing genomic analysis tools are often organized around literal views of genomes as linear strings. Even when information is highly condensed, these views grow cumbersome as larger numbers of genomes are added. Data aggregation and summarization methods from the field of visual analytics can provide abstracted comparative views, suitable for sifting large multi-genome datasets to identify critical similarities and differences. We introduce a software system for visual analysis of comparative genomics data. The system automates the process of data integration, and provides the analysis platform to identify and explore features of interest within these large datasets. GenoSets borrows techniques from business intelligence and visual analytics to provide a rich interface of interactive visualizations supported by a multi-dimensional data warehouse. In GenoSets, visual analytic approaches are used to enable querying based on orthology, functional assignment, and taxonomic or user-defined groupings of genomes. GenoSets links this information together with coordinated, interactive visualizations for both detailed and high-level categorical analysis of summarized data. GenoSets has been designed to simplify the exploration of multiple genome datasets and to facilitate reasoning about genomic comparisons. Case examples are included showing the use of this system in the analysis of 12 Brucella genomes. GenoSets software and the case study dataset are freely available at http://genosets.uncc.edu. We demonstrate that the integration of genomic data using a coordinated multiple view approach can simplify the exploration of large comparative genomic data sets, and facilitate reasoning about comparisons and features of interest.

  19. Net Analyte Signal Standard Additions Method for Simultaneous Determination of Sulfamethoxazole and Trimethoprim in Pharmaceutical Formulations and Biological Fluids

    OpenAIRE

    Givianrad, M. H.; Mohagheghian, M.

    2012-01-01

    The applicability of a novel net analyte signal standard addition method (NASSAM) to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim was verified by UV-visible spectrophotometry. The results confirmed that the net analyte signal standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. Moreover, applying the net analyte signal standard a...

  20. Validation of an advanced analytical procedure applied to the measurement of environmental radioactivity.

    Science.gov (United States)

    Thanh, Tran Thien; Vuong, Le Quang; Ho, Phan Long; Chuong, Huynh Dinh; Nguyen, Vo Hoang; Tao, Chau Van

    2018-04-01

    In this work, an advanced analytical procedure was applied to calculate radioactivity in spiked water samples in a close geometry gamma spectroscopy. It included MCNP-CP code in order to calculate the coincidence summing correction factor (CSF). The CSF results were validated by a deterministic method using ETNA code for both p-type HPGe detectors. It showed that a good agreement for both codes. Finally, the validity of the developed procedure was confirmed by a proficiency test to calculate the activities of various radionuclides. The results of the radioactivity measurement with both detectors using the advanced analytical procedure were received the ''Accepted'' statuses following the proficiency test. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Application of nuclear analytical methods to heavy metal pollution studies of estuaries

    International Nuclear Information System (INIS)

    Anders, B.; Junge, W.; Knoth, J.; Michaelis, W.; Pepelnik, R.; Schwenke, H.

    1984-01-01

    Important objectives of heavy metal pollution studies of estuaries are the understanding of the transport phenomena in these complex ecosystems and the discovery of the pollution history and the geochemical background. Such studies require high precision and accuracy of the analytical methods. Moreover, pronounced spatial heterogeneities and temporal variabilities that are typical for estuaries necessitate the analysis of a great number of samples if relevant results are to be obtained. Both requirements can economically be fulfilled by a proper combination of analytical methods. Applications of energy-dispersive X-ray fluorescence analysis with total reflection of the exciting beam at the sample support and of neutron activation analysis with both thermal and fast neutrons are reported in the light of pollution studies performed in the Lower Elbe River. (orig.)

  2. Evaluation and selection of in-situ leaching mining method using analytic hierarchy process

    International Nuclear Information System (INIS)

    Zhao Heyong; Tan Kaixuan; Liu Huizhen

    2007-01-01

    According to the complicated conditions and main influence factors of in-situ leaching min- ing, a model and processes of analytic hierarchy are established for evaluation and selection of in-situ leaching mining methods based on analytic hierarchy process. Taking a uranium mine in Xinjiang of China for example, the application of this model is presented. The results of analyses and calculation indicate that the acid leaching is the optimum project. (authors)

  3. Experimental design and multiple response optimization. Using the desirability function in analytical methods development.

    Science.gov (United States)

    Candioti, Luciana Vera; De Zan, María M; Cámara, María S; Goicoechea, Héctor C

    2014-06-01

    A review about the application of response surface methodology (RSM) when several responses have to be simultaneously optimized in the field of analytical methods development is presented. Several critical issues like response transformation, multiple response optimization and modeling with least squares and artificial neural networks are discussed. Most recent analytical applications are presented in the context of analytLaboratorio de Control de Calidad de Medicamentos (LCCM), Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, C.C. 242, S3000ZAA Santa Fe, ArgentinaLaboratorio de Control de Calidad de Medicamentos (LCCM), Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, C.C. 242, S3000ZAA Santa Fe, Argentinaical methods development, especially in multiple response optimization procedures using the desirability function. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Method of analytic continuation by duality in QCD: Beyond QCD sum rules

    International Nuclear Information System (INIS)

    Kremer, M.; Nasrallah, N.F.; Papadopoulos, N.A.; Schilcher, K.

    1986-01-01

    We present the method of analytic continuation by duality which allows the approximate continuation of QCD amplitudes to small values of the momentum variables where direct perturbative calculations are not possible. This allows a substantial extension of the domain of applications of hadronic QCD phenomenology. The method is illustrated by a simple example which shows its essential features

  5. Analytical method of spectra calculations in the Bargmann representation

    International Nuclear Information System (INIS)

    Maciejewski, Andrzej J.; Przybylska, Maria; Stachowiak, Tomasz

    2014-01-01

    We formulate a universal method for solving an arbitrary quantum system which, in the Bargmann representation, is described by a system of linear equations with one independent variable, such as one- and multi-photon Rabi models, or N level systems interacting with a single mode of the electromagnetic field and their various generalizations. We explain three types of conditions that determine the spectrum and show their usage for two deformations of the Rabi model. We prove that the spectra of both models are just zeros of transcendental functions, which in one case are given explicitly in terms of confluent Heun functions. - Highlights: • Analytical method of spectrum determination in Bargmann representation is proposed. • Three types of conditions determining spectrum are identified. • Method to two generalizations of the Rabi system is applied

  6. Methods of Environmental Impact Assessment in Colombia

    Directory of Open Access Journals (Sweden)

    Javier Toro Calderón

    2013-10-01

    Full Text Available The Environmental Impact Assessment (EIA in Colombia constitutes the primary tool for making decisions with respect to projects, works and activities (PWA with potential for significant environmental impacts. In the case of the infrastructure of the PWA, the EIA is mandatory and determines the environmental license (EL for construction and operation. This paper analyzes the methods used to assess the environmental impact of the PWA that have applied for licenses with the Ministry of Environment and Sustainable Development. It was found that the method most frequently used is the qualitative proposal by Conesa, with modifications that reduce the effectiveness of the EIA and favor the subjectivity and bias of the evaluator. Finally a series of recom­mendations to improve the process in the country are proposed.

  7. Bio- and chemiluminescence imaging in analytical chemistry

    International Nuclear Information System (INIS)

    Roda, Aldo; Guardigli, Massimo; Pasini, Patrizia; Mirasoli, Mara; Michelini, Elisa; Musiani, Monica

    2005-01-01

    Bio- and chemiluminescence imaging techniques combine the high sensitivity of bio- and chemiluminescence detection with the ability of current light imaging devices to localize and quantify light emission down to the single-photon level. These techniques have been successfully exploited for the development of sensitive analytical methods relying on the evaluation of the spatial distribution of the light emitted from a target sample. In this paper, we report on recent applications of bio- and chemiluminescence imaging for in vitro and in vivo assays, including: quantitative assays performed in various analytical formats, such as microtiter plates, microarrays and miniaturized analytical devices, used in the pharmaceutical, clinical, diagnostic and environmental fields; luminescence imaging microscopy based on enzymatic, immunohistochemical and in situ hybridization reactions for the localization of metabolites, enzymes, antigens and gene sequences in cells and tissues; whole-body luminescence imaging in live animals for evaluating biological and pathological processes and for pharmacological studies

  8. A new analytical method to solve the heat equation for a multi-dimensional composite slab

    International Nuclear Information System (INIS)

    Lu, X; Tervola, P; Viljanen, M

    2005-01-01

    A novel analytical approach has been developed for heat conduction in a multi-dimensional composite slab subject to time-dependent boundary changes of the first kind. Boundary temperatures are represented as Fourier series. Taking advantage of the periodic properties of boundary changes, the analytical solution is obtained and expressed explicitly. Nearly all the published works necessitate searching for associated eigenvalues in solving such a problem even for a one-dimensional composite slab. In this paper, the proposed method involves no iterative computation such as numerically searching for eigenvalues and no residue evaluation. The adopted method is simple which represents an extension of the novel analytical approach derived for the one-dimensional composite slab. Moreover, the method of 'separation of variables' employed in this paper is new. The mathematical formula for solutions is concise and straightforward. The physical parameters are clearly shown in the formula. Further comparison with numerical calculations is presented

  9. Study on the Analytical Method for Determination of P-32 in Human Hair

    International Nuclear Information System (INIS)

    Syarbaini; Lubis, E.; Sarwani

    1996-01-01

    Neutron doses due to accident criticality can be estimated by measuring of radionuclide of neutron activation products in human hair. In this work, the analytical method for the determination of P-32 in neutron irradiated hair sample by G.A Siwabessy reactor has been studied. This analytical method consists of dissolving of human hair sample by 10 M HNO3, separation dan purification of P-32 by precipitation as ammonium molibdophosphate finally, the precipitate was measured by low backgroundα/βcounter. The minimum detectable activity of P-32 was 0,05 Bq at a background of 4,6 cpm and with a counting efficiency of 55 % for a 30 minute counting time

  10. Analytic moment method calculations of the drift wave spectrum

    International Nuclear Information System (INIS)

    Thayer, D.R.; Molvig, K.

    1985-11-01

    A derivation and approximate solution of renormalized mode coupling equations describing the turbulent drift wave spectrum is presented. Arguments are given which indicate that a weak turbulence formulation of the spectrum equations fails for a system with negative dissipation. The inadequacy of the weak turbulence theory is circumvented by utilizing a renormalized formation. An analytic moment method is developed to approximate the solution of the nonlinear spectrum integral equations. The solution method employs trial functions to reduce the integral equations to algebraic equations in basic parameters describing the spectrum. An approximate solution of the spectrum equations is first obtained for a mode dissipation with known solution, and second for an electron dissipation in the NSA

  11. Application of Statistical Methods to Activation Analytical Results near the Limit of Detection

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Wanscher, B.

    1978-01-01

    Reporting actual numbers instead of upper limits for analytical results at or below the detection limit may produce reliable data when these numbers are subjected to appropriate statistical processing. Particularly in radiometric methods, such as activation analysis, where individual standard...... deviations of analytical results may be estimated, improved discrimination may be based on the Analysis of Precision. Actual experimental results from a study of the concentrations of arsenic in human skin demonstrate the power of this principle....

  12. Analytical solutions to compartmental indoor air quality models with application to environmental tobacco smoke concentrations measured in a house.

    Science.gov (United States)

    Ott, Wayne R; Klepeis, Neil E; Switzer, Paul

    2003-08-01

    This paper derives the analytical solutions to multi-compartment indoor air quality models for predicting indoor air pollutant concentrations in the home and evaluates the solutions using experimental measurements in the rooms of a single-story residence. The model uses Laplace transform methods to solve the mass balance equations for two interconnected compartments, obtaining analytical solutions that can be applied without a computer. Environmental tobacco smoke (ETS) sources such as the cigarette typically emit pollutants for relatively short times (7-11 min) and are represented mathematically by a "rectangular" source emission time function, or approximated by a short-duration source called an "impulse" time function. Other time-varying indoor sources also can be represented by Laplace transforms. The two-compartment model is more complicated than the single-compartment model and has more parameters, including the cigarette or combustion source emission rate as a function of time, room volumes, compartmental air change rates, and interzonal air flow factors expressed as dimensionless ratios. This paper provides analytical solutions for the impulse, step (Heaviside), and rectangular source emission time functions. It evaluates the indoor model in an unoccupied two-bedroom home using cigars and cigarettes as sources with continuous measurements of carbon monoxide (CO), respirable suspended particles (RSP), and particulate polycyclic aromatic hydrocarbons (PPAH). Fine particle mass concentrations (RSP or PM3.5) are measured using real-time monitors. In our experiments, simultaneous measurements of concentrations at three heights in a bedroom confirm an important assumption of the model-spatial uniformity of mixing. The parameter values of the two-compartment model were obtained using a "grid search" optimization method, and the predicted solutions agreed well with the measured concentration time series in the rooms of the home. The door and window positions in

  13. An analytical method for neutron thermalization calculations in heterogenous reactors

    Energy Technology Data Exchange (ETDEWEB)

    Pop-Jordanov, J [Boris Kidric Institute of Nuclear Sciences, Vinca, Belgrade (Yugoslavia)

    1965-07-01

    It is well known that the use of the diffusion approximation for stumethods are rather laborious and require the use of large digital computers. In this paper, the use of the diffusion approximation in absorbing media has been avoided, but the treatment remained analytical, thus simplifying practical calculations.

  14. An analytical method for neutron thermalization calculations in heterogenous reactors

    International Nuclear Information System (INIS)

    Pop-Jordanov, J.

    1965-01-01

    It is well known that the use of the diffusion approximation for studying neutron thermalization in heterogeneous reactors may result in considerable errors. On the other hand, more exact numerical methods are rather laborious and require the use of large digital computers. In this paper, the use of the diffusion approximation in absorbing media has been avoided, but the treatment remained analytical, thus simplifying practical calculations

  15. The auxiliary field method and approximate analytical solutions of the Schroedinger equation with exponential potentials

    Energy Technology Data Exchange (ETDEWEB)

    Silvestre-Brac, Bernard [LPSC Universite Joseph Fourier, Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, Avenue des Martyrs 53, F-38026 Grenoble-Cedex (France); Semay, Claude; Buisseret, Fabien [Groupe de Physique Nucleaire Theorique, Universite de Mons-Hainaut, Academie universitaire Wallonie-Bruxelles, Place du Parc 20, B-7000 Mons (Belgium)], E-mail: silvestre@lpsc.in2p3.fr, E-mail: claude.semay@umh.ac.be, E-mail: fabien.buisseret@umh.ac.be

    2009-06-19

    The auxiliary field method is a new and efficient way to compute approximate analytical eigenenergies of the Schroedinger equation. This method has already been successfully applied to the case of central potentials of power-law and logarithmic forms. In the present work, we show that the Schroedinger equation with exponential potentials of the form -{alpha}r{sup {lambda}}exp(-{beta}r) can also be analytically solved by using the auxiliary field method. Closed formulae giving the critical heights and the energy levels of these potentials are presented. Special attention is drawn to the Yukawa potential and the pure exponential potential.

  16. The auxiliary field method and approximate analytical solutions of the Schroedinger equation with exponential potentials

    International Nuclear Information System (INIS)

    Silvestre-Brac, Bernard; Semay, Claude; Buisseret, Fabien

    2009-01-01

    The auxiliary field method is a new and efficient way to compute approximate analytical eigenenergies of the Schroedinger equation. This method has already been successfully applied to the case of central potentials of power-law and logarithmic forms. In the present work, we show that the Schroedinger equation with exponential potentials of the form -αr λ exp(-βr) can also be analytically solved by using the auxiliary field method. Closed formulae giving the critical heights and the energy levels of these potentials are presented. Special attention is drawn to the Yukawa potential and the pure exponential potential

  17. Selenium contaminated waters: An overview of analytical methods, treatment options and recent advances in sorption methods.

    Science.gov (United States)

    Santos, Sílvia; Ungureanu, Gabriela; Boaventura, Rui; Botelho, Cidália

    2015-07-15

    Selenium is an essential trace element for many organisms, including humans, but it is bioaccumulative and toxic at higher than homeostatic levels. Both selenium deficiency and toxicity are problems around the world. Mines, coal-fired power plants, oil refineries and agriculture are important examples of anthropogenic sources, generating contaminated waters and wastewaters. For reasons of human health and ecotoxicity, selenium concentration has to be controlled in drinking-water and in wastewater, as it is a potential pollutant of water bodies. This review article provides firstly a general overview about selenium distribution, sources, chemistry, toxicity and environmental impact. Analytical techniques used for Se determination and speciation and water and wastewater treatment options are reviewed. In particular, published works on adsorption as a treatment method for Se removal from aqueous solutions are critically analyzed. Recent published literature has given particular attention to the development and search for effective adsorbents, including low-cost alternative materials. Published works mostly consist in exploratory findings and laboratory-scale experiments. Binary metal oxides and LDHs (layered double hydroxides) have presented excellent adsorption capacities for selenium species. Unconventional sorbents (algae, agricultural wastes and other biomaterials), in raw or modified forms, have also led to very interesting results with the advantage of their availability and low-cost. Some directions to be considered in future works are also suggested. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Computer science handbook. Vol. 13.3. Environmental computer science. Computer science methods for environmental protection and environmental research

    International Nuclear Information System (INIS)

    Page, B.; Hilty, L.M.

    1994-01-01

    Environmental computer science is a new partial discipline of applied computer science, which makes use of methods and techniques of information processing in environmental protection. Thanks to the inter-disciplinary nature of environmental problems, computer science acts as a mediator between numerous disciplines and institutions in this sector. The handbook reflects the broad spectrum of state-of-the art environmental computer science. The following important subjects are dealt with: Environmental databases and information systems, environmental monitoring, modelling and simulation, visualization of environmental data and knowledge-based systems in the environmental sector. (orig.) [de

  19. Fuel Cycle Externalities: Analytical Methods and Issues, Report 2

    International Nuclear Information System (INIS)

    Barnthouse, L.W.; Cada, G.F.; Cheng, M.-D.; Easterly, C.E.; Kroodsma, R.L.; Lee, R.; Shriner, D.S.; Tolbert, V.R.; Turner, R.S.

    1994-01-01

    that also have not been fully addressed. This document contains two types of papers that seek to fill part of this void. Some of the papers describe analytical methods that can be applied to one of the five steps of the damage function approach. The other papers discuss some of the complex issues that arise in trying to estimate externalities. This report, the second in a series of eight reports, is part of a joint study by the U.S. Department of Energy (DOE) and the Commission of the European Communities (EC)* on the externalities of fuel cycles. Most of the papers in this report were originally written as working papers during the initial phases of this study. The papers provide descriptions of the (non-radiological) atmospheric dispersion modeling that the study uses; reviews much of the relevant literature on ecological and health effects, and on the economic valuation of those impacts; contains several papers on some of the more complex and contentious issues in estimating externalities; and describes a method for depicting the quality of scientific information that a study uses. The analytical methods and issues that this report discusses generally pertain to more than one of the fuel cycles, though not necessarily to all of them. The report is divided into six parts, each one focusing on a different subject area

  20. Phonon dispersion on Ag (100) surface: A modified analytic embedded atom method study

    International Nuclear Information System (INIS)

    Zhang Xiao-Jun; Chen Chang-Le

    2016-01-01

    Within the harmonic approximation, the analytic expression of the dynamical matrix is derived based on the modified analytic embedded atom method (MAEAM) and the dynamics theory of surface lattice. The surface phonon dispersions along three major symmetry directions, and XM-bar are calculated for the clean Ag (100) surface by using our derived formulas. We then discuss the polarization and localization of surface modes at points X-bar and M-bar by plotting the squared polarization vectors as a function of the layer index. The phonon frequencies of the surface modes calculated by MAEAM are compared with the available experimental and other theoretical data. It is found that the present results are generally in agreement with the referenced experimental or theoretical results, with a maximum deviation of 10.4%. The agreement shows that the modified analytic embedded atom method is a reasonable many-body potential model to quickly describe the surface lattice vibration. It also lays a significant foundation for studying the surface lattice vibration in other metals. (paper)

  1. Analytical method for high resolution liquid chromatography for quality control French Macaw

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Torres Amaro, Leonid; Menendez Castillo, Rosa; Sanchez, Esther; Martinez Espinosa, Vivian; Gonzalez, Maria Lidia; Rodriguez, Carlos

    2007-01-01

    Was developed and validated an analytical method for high resolution liquid chromatography applicable to quality control of drugs dry French Macaw (Senna alata L. Roxb.) With ultraviolet detection at 340 nm. The method for high resolution liquid chromatography used to quantify the sennosides A and B, main components, was validated and proved to be specific, linear, precise and accurate. (Author)

  2. Development for ultra-trace analysis method of U and Pu in safeguards environmental samples at the clean facility

    International Nuclear Information System (INIS)

    Takahashi, Masato; Magara, Masaaki; Sakurai, Satoshi

    2002-01-01

    Based on the strengthen safeguard program of the IAEA to detect undeclared nuclear activities and nuclear materials, the method of precise and accurate isotope ratio determination for uranium and plutonium in the environmental samples (cotton swipes) has been developed at JAERI. The samples should be treated in clean environment in order to secure the analytical reliability by eliminating external contamination from the samples containing trace amount of uranium and plutonium. Since the measurement by ICP-MS is favorable to bulk analysis from view points of analytical capacity and operation simplicity, we have studied sample preparation procedures for the trace amount of uranium and plutonium to be applied to ICP-MS. Up to the present, interfering factors involved during analytical processes and the ICP-MS measurement of uranium and plutonium were examined. As a result, uranium isotope measurement more than 100 pg became possible at JAERI clean facility by diminishing uranium blank introduced in the entire sample treatment procedure. And also, the estimation of plutonium recovery yield and uranium decontamination factor suggested the possibility in plutonium isotope measurement more than 100 fg. (author)

  3. Application of FEM analytical method for hydrogen migration behaviour in Zirconium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Arioka, K; Ohta, H [Takasago Research and Development Center, Mitsubishi Heavy Industries Ltd, Hyogo-ken (Japan)

    1997-02-01

    It is well recognized that the hydriding behaviours of Zirconium alloys are very significant problems as a safety issues. Also, it is well known that the diffusion of hydrogen in Zirconium alloys are affected not only by concentration but also temperature gradient. But in actual component, especially heat transfer tube such as fuel rod, we can not avoid the temperature gradient in some degree. So, it is very useful to develop the computer code which can analyze the hydrogen diffusion and precipitation behaviours under temperature gradient as a function of the structure of fuel rod. For this objective, we have developed the computer code for hydrogen migration behaviour using FEM analytical methods. So, following items are presented and discussed. Analytical method and conditions; correlation between the computed and test results; application to designing studies. (author). 8 refs, 4 figs, 2 tabs.

  4. A Semi-Analytical Method for the PDFs of A Ship Rolling in Random Oblique Waves

    Science.gov (United States)

    Liu, Li-qin; Liu, Ya-liu; Xu, Wan-hai; Li, Yan; Tang, You-gang

    2018-03-01

    The PDFs (probability density functions) and probability of a ship rolling under the random parametric and forced excitations were studied by a semi-analytical method. The rolling motion equation of the ship in random oblique waves was established. The righting arm obtained by the numerical simulation was approximately fitted by an analytical function. The irregular waves were decomposed into two Gauss stationary random processes, and the CARMA (2, 1) model was used to fit the spectral density function of parametric and forced excitations. The stochastic energy envelope averaging method was used to solve the PDFs and the probability. The validity of the semi-analytical method was verified by the Monte Carlo method. The C11 ship was taken as an example, and the influences of the system parameters on the PDFs and probability were analyzed. The results show that the probability of ship rolling is affected by the characteristic wave height, wave length, and the heading angle. In order to provide proper advice for the ship's manoeuvring, the parametric excitations should be considered appropriately when the ship navigates in the oblique seas.

  5. Comparing rapid methods for detecting Listeria in seafood and environmental samples using the most probably number (MPN) technique.

    Science.gov (United States)

    Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C

    2012-02-15

    The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Determination of pharmaceuticals in environmental and biological matrices using pressurised liquid extraction--are we developing sound extraction methods?

    DEFF Research Database (Denmark)

    Runnqvist, Hannah; Bak, Søren Alex; Hansen, Martin

    2010-01-01

    Pressurised liquid extraction (PLE) is now a well established and extensively applied extraction technique in environmental analysis for pollutants such as persistent organic pollutants (POPs). During the past decade, an emerging group of environmentally interesting analytes are pharmaceuticals...

  7. Investigations of phosphate coatings of galvanized steel sheets by a surface-analytical multi-method approach

    International Nuclear Information System (INIS)

    Bubert, H.; Garten, R.; Klockenkaemper, R.; Puderbach, H.

    1983-01-01

    Corrosion protective coatings on galvanized steel sheets have been studied by a combination of SEM, EDX, AES, ISS and SIMS. Analytical statements concerning such rough, poly-crystalline and contaminated surfaces of technical samples are quite difficult to obtain. The use of a surface-analytical multi-method approach overcomes, the intrinsic limitations of the individual method applied, thus resulting in a consistent picture of those technical surfaces. Such results can be used to examine technical faults and to optimize the technical process. (Author)

  8. A Novel Method for Analytical Solutions of Fractional Partial Differential Equations

    OpenAIRE

    Mehmet Ali Akinlar; Muhammet Kurulay

    2013-01-01

    A new solution technique for analytical solutions of fractional partial differential equations (FPDEs) is presented. The solutions are expressed as a finite sum of a vector type functional. By employing MAPLE software, it is shown that the solutions might be extended to an arbitrary degree which makes the present method not only different from the others in the literature but also quite efficient. The method is applied to special Bagley-Torvik and Diethelm fractional differential equations as...

  9. The riddle of Siegfried: exploring methods and psychological perspectives in analytical psychology.

    Science.gov (United States)

    Barreto, Marco Heleno

    2016-02-01

    Jung's dream of the killing of Siegfried poses a riddle: why did the unconscious choose precisely Siegfried as the hero to be murdered? Jung himself declares that he does not know. This paper attempts to decipher this riddle using three distinct methodological approaches accepted by Jung, two of them in fact grounded in his theories of dream interpretation. Besides presenting some possible answers to the riddle of Siegfried, this interpretative reflection brings to light the discrepancy of the psychological perspectives created by the heterogeneity of methods within analytical psychology. © 2016, The Society of Analytical Psychology.

  10. Comprehension of complex biological processes by analytical methods: how far can we go using mass spectrometry?

    International Nuclear Information System (INIS)

    Gerner, C.

    2013-01-01

    Comprehensive understanding of complex biological processes is the basis for many biomedical issues of great relevance for modern society including risk assessment, drug development, quality control of industrial products and many more. Screening methods provide means for investigating biological samples without research hypothesis. However, the first boom of analytical screening efforts has passed and we again need to ask whether and how to apply screening methods. Mass spectrometry is a modern tool with unrivalled analytical capacities. This applies to all relevant characteristics of analytical methods such as specificity, sensitivity, accuracy, multiplicity and diversity of applications. Indeed, mass spectrometry qualifies to deal with complexity. Chronic inflammation is a common feature of almost all relevant diseases challenging our modern society; these diseases are apparently highly diverse and include arteriosclerosis, cancer, back pain, neurodegenerative diseases, depression and other. The complexity of mechanisms regulating chronic inflammation is the reason for the practical challenge to deal with it. The presentation shall give an overview of capabilities and limitations of the application of this analytical tool to solve critical questions with great relevance for our society. (author)

  11. An analytical method for computing atomic contact areas in biomolecules.

    Science.gov (United States)

    Mach, Paul; Koehl, Patrice

    2013-01-15

    We propose a new analytical method for detecting and computing contacts between atoms in biomolecules. It is based on the alpha shape theory and proceeds in three steps. First, we compute the weighted Delaunay triangulation of the union of spheres representing the molecule. In the second step, the Delaunay complex is filtered to derive the dual complex. Finally, contacts between spheres are collected. In this approach, two atoms i and j are defined to be in contact if their centers are connected by an edge in the dual complex. The contact areas between atom i and its neighbors are computed based on the caps formed by these neighbors on the surface of i; the total area of all these caps is partitioned according to their spherical Laguerre Voronoi diagram on the surface of i. This method is analytical and its implementation in a new program BallContact is fast and robust. We have used BallContact to study contacts in a database of 1551 high resolution protein structures. We show that with this new definition of atomic contacts, we generate realistic representations of the environments of atoms and residues within a protein. In particular, we establish the importance of nonpolar contact areas that complement the information represented by the accessible surface areas. This new method bears similarity to the tessellation methods used to quantify atomic volumes and contacts, with the advantage that it does not require the presence of explicit solvent molecules if the surface of the protein is to be considered. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.

  12. A comparison of two analytical evaluation methods for educational computer games for young children

    NARCIS (Netherlands)

    Bekker, M.M.; Baauw, E.; Barendregt, W.

    2008-01-01

    In this paper we describe a comparison of two analytical methods for educational computer games for young children. The methods compared in the study are the Structured Expert Evaluation Method (SEEM) and the Combined Heuristic Evaluation (HE) (based on a combination of Nielsen’s HE and the

  13. Analytical pyrolysis and stable isotope analyses reveal past environmental changes in coralloid speleothems from Easter Island (Chile).

    Science.gov (United States)

    Miller, Ana Z; De la Rosa, José M; Jiménez-Morillo, Nicasio T; Pereira, Manuel F C; González-Pérez, José A; Calaforra, José M; Saiz-Jimenez, Cesareo

    2016-08-26

    This study comprises an innovative approach based on the combination of chromatography (analytical pyrolysis and pyrolysis compound-specific isotope analysis (Py-CSIA)), light stable isotopes, microscopy and mineralogy analyses to characterize the internal layering of coralloid speleothems from the Ana Heva lava tube in Easter Island (Chile). This multidisciplinary proxy showed that the speleothems consist of banded siliceous materials of low crystallinity with different mineralogical compositions and a significant contribution of organic carbon. Opal-A constitutes the outermost grey layer of the coralloids, whereas calcite and amorphous Mg hydrate silicate are the major components of the inner whitish and honey-brown layers, respectively. The differences found in the mineralogical, elemental, molecular and isotopic composition of these distinct coloured layers are related to environmental changes during speleothem development. Stable isotopes and analytical pyrolysis suggested alterations in the water regime, pointing to wetter conditions during the formation of the Ca-rich layer and a possible increase in the amount of water dripping into the cave. The trend observed for δ(15)N values suggested an increase in the average temperature over time, which is consistent with the so-called climate warming during the Holocene. The pyrolysis compound-specific isotope analysis of each speleothem layer showed a similar trend with the bulk δ(13)C values pointing to the appropriateness of direct Py-CSIA in paleoenvironmental studies. The δ(13)C values for n-alkanes reinforced the occurrence of a drastic environmental change, indicating that the outermost Opal layer was developed under drier and more arid environmental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Intercalibration of analytical methods on marine environmental samples. Results of MEDPOL II exercise for the intercomparison of trace element measurements on mussel tissue homogenate and marine sediment (MA-M-2/TM and SD-N-1/2/TM)

    International Nuclear Information System (INIS)

    1986-12-01

    Mussels and coastal sediments are often considered as pollution indicators of the marine environment. These intercalibration exercises were organised in order to check the analytical performances of environmental laboratories. The samples MA-M-2/TM of Mediterranean mussels and SD-N-1/2/TM of surface sediment from the Scheldt Estuary (North Sea) were analysed by 19 laboratories for determination of 15 elements: Ag, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Sb, Se, V and Zn. The analytical methods of atomic absorption spectroscopy, neutron activation analysis and voltametry were used in this intercomparison. For the mussel MA-M-2/TM, 65% of the reported coefficients of variation lie between 0 and 10%, 25% are between 10 and 20%, 9% between 20 and 30% and only 1% higher than 30%. In the case of the sediment SD-N-1/2/TM, 90% of the reported coefficients of variation lie between 0 and 10% and the remaining 10% are between 10 and 20%. The total number of outliers is moderate (9.2% of all results in the case of MA-M-2/TM and 3.0% in the case of SD-N-1/2/TM)

  15. Analytical method for Buddleja colorants in foods.

    Science.gov (United States)

    Aoki, H; Kuze, N; Ichi, T; Koda, T

    2001-04-01

    Buddleja yellow colorant derived from Buddleja officinalis Maxim. has recently been approved for use as a new kind of natural colorant for food additives in China. In order to distinguish Buddleja yellow colorant from other yellow colorants, two known phenylpropanoid glycosides, acteoside (= verbascoside) and poliumoside, were isolated from the colorant as marker substances for Buddleja yellow colorant. Poliumoside has not been detected in B. officinalis Maxim. previously. These phenylpropanoid glycosides were not detected in the fruits of Gardenia jasminoides Ellis or in the stamens of the flowers of Crocus sativus L., which also contain crocetin derivatives as coloring components, using a photodiode array and mass chromatograms. Thus, an analytical HPLC method was developed to distinguish foods that have been colored with yellow colorants containing crocetin derivatives, using phenylpropanoid glycosides as markers.

  16. Examining environmental drivers of spatial variability in aflatoxin ...

    African Journals Online (AJOL)

    Examining environmental drivers of spatial variability in aflatoxin accumulation in Kenyan maize: potential utility in risk prediction models. ... however, because of high sampling cost and lack of affordable and accurate analytical methods.

  17. Evaluation of FTIR-based analytical methods for the analysis of simulated wastes

    International Nuclear Information System (INIS)

    Rebagay, T.V.; Cash, R.J.; Dodd, D.A.; Lockrem, L.L.; Meacham, J.E.; Winkelman, W.D.

    1994-01-01

    Three FTIR-based analytical methods that have potential to characterize simulated waste tank materials have been evaluated. These include: (1) fiber optics, (2) modular transfer optic using light guides equipped with non-contact sampling peripherals, and (3) photoacoustic spectroscopy. Pertinent instrumentation and experimental procedures for each method are described. The results show that the near-infrared (NIR) region of the infrared spectrum is the region of choice for the measurement of moisture in waste simulants. Differentiation of the NIR spectrum, as a preprocessing steps, will improve the analytical result. Preliminary data indicate that prominent combination bands of water and the first overtone band of the ferrocyanide stretching vibration may be utilized to measure water and ferrocyanide species simultaneously. Both near-infrared and mid-infrared spectra must be collected, however, to measure ferrocyanide species unambiguously and accurately. For ease of sample handling and the potential for field or waste tank deployment, the FTIR-Fiber Optic method is preferred over the other two methods. Modular transfer optic using light guides and photoacoustic spectroscopy may be used as backup systems and for the validation of the fiber optic data

  18. VKTA Rossendorf: Laboratory for Environmental and Radionuclide Analysis

    International Nuclear Information System (INIS)

    Koehler, M.; Knappik, R.; Fiola, K.

    2015-01-01

    The VKTA (Nuclear Engineering and Analytics Inc.) is charged by the Free State of Saxony with the decommissioning and waste management of the nuclear installations at the research site Dresden-Rossendorf. This task includes the safe management and disposal of fissile material and radioactive wastes. The acquired expertise and our solution-oriented way of working are the basis for a varied range of services especially the environmental and radionuclide analyzes. The Laboratory for Environmental and Radionuclide Analysis is accredited according to DIN EN ISO/IEC 17025 and provides a sound range of analytical and metrological services including their coordination and management. The personnel and the rooms, measuring and technical equipment are particularly designed for our special field, the measuring of radioactivity. We are focussed on measuring artificial and natural radionuclides in a wide range of activity and in different sample matrices (e.g., urine, faeces, metals, soil, concrete, food, liquids). With the flexible accreditation of the radionuclide analytics the Laboratory is able to react shortly to changing requirements in decommissioning, environmental monitoring and radiation protection. Essential chemical and radiochemical methods are e.g.: · Alpha particle spectrometry, · Liquid scintillation counting, · gamma ray spectrometry, including Ultra-Low-Level, · High-resolution ICP-MS, · Chromatographic methods such as ion chromatography, gas chromatography, HPLC, · Electrochemical measuring methods such as potentiometry, voltammetry. The Laboratory offers analytical services to the research site Dresden-Rossendorf and national and international customers adapting its analytical procedures to the special needs of customers. The presentation demonstrates on the basis of examples the work of Laboratory within the scope of decommissioning of nuclear facilities, especially at a research site, from radiological preliminary investigation to declaration of

  19. Analytical methods associated with the recovery of uranium

    International Nuclear Information System (INIS)

    Dixon, K.

    1983-01-01

    This report summarizes various approaches made to the analysis of materials arising from the processing of Karoo deposits for uranium. These materials include head and residue samples, aqueous solutions and organic solvents and, finally, the precipitated cakes of the elements recovered, i.e. uranium, molybdenum, and arsenic. Analysis was required for these elements and also vanadium, carbon, sulphur, and carbonate in the head and residue samples. The concentration of uranium, molybdenum, and arsenic, other than in the precipitated cakes, ranges from 1 to 2000μg/g, and that of carbon, sulphur, and carbonate from 0,1 to 5 per cent. The analysis of cakes necessitates the determination of silver, arsenic, iron, copper, calcium, magnesium, manganese, molybdenum, lead, tin, titanium, and vanadium within the range 1 to 1000μg/g, and of sodium and silica within the range 10 to 20 000μg/g. The methods used include combustion methods for carbon, sulphur, and carbonate, and atomic-absorption, X-ray-fluorescence, and emission methods for the other analytes. The accuracy of the analysis is within 10 per cent

  20. Advances in Alkenone Paleotemperature Proxies: Analytical Methods, Novel Structures and Haptophyte Species, Biosynthesis, New indices and Ecological Aspects

    Science.gov (United States)

    Huang, Y.; Longo, W. M.; Zheng, Y.; Richter, N.; Dillon, J. T.; Theroux, S.; D'Andrea, W. J.; Toney, J. L.; Wang, L.; Amaral-Zettler, L. A.

    2017-12-01

    Alkenones are mature, well-established paleo-sea surface temperature proxies that have been widely applied for more than three decades. However, recent advances across a broad range of alkenone-related topics at Brown University are inviting new paleoclimate and paleo-environmental applications for these classic biomarkers. In this presentation, I will summarize our progress in the following areas: (1) Discovery of a freshwater alkenone-producing haptophyte species and structural elucidation of novel alkenone structures unique to the species, performing in-situ temperature calibrations, and classifying alkenone-producing haptophytes into three groups based on molecular ecological approaches (with the new species belonging to Group I Isochrysidales); (2) A global survey of Group I haptophyte distributions and environmental conditions favoring the presence of this alga, as well as examples of using Group I alkenones for paleotemperature reconstructions; (3) New gas chromatographic columns that allow unprecedented resolution of alkenones and alkenoates and associated structural isomers, and development of a new suite of paleotemperature and paleoenvironmental proxies; (4) A new liquid chromatographic separation technique that allows efficient cleanup of alkenones and alkenoates (without the need for saponification) for subsequent coelution-free gas chromatographic analysis; (5) Novel structural features revealed by new analytical methods that now allow a comprehensive re-assessment of taxonomic features of various haptophyte species, with principal component analysis capable of fully resolving species biomarker distributions; (6) Development of UK37 double prime (UK37'') for Group II haptophytes (e.g., those occurring in saline lakes and estuaries), that differs from the traditional unsaturation indices used for SST reconstructions; (7) New assessment of how mixed inputs from different alkenone groups may affect SST reconstructions in marginal ocean environments and

  1. ENVIRONMENTAL RESEARCH BRIEF : ANALYTIC ELEMENT MODELING OF GROUND-WATER FLOW AND HIGH PERFORMANCE COMPUTING

    Science.gov (United States)

    Several advances in the analytic element method have been made to enhance its performance and facilitate three-dimensional ground-water flow modeling in a regional aquifer setting. First, a new public domain modular code (ModAEM) has been developed for modeling ground-water flow ...

  2. Method and system for environmentally adaptive fault tolerant computing

    Science.gov (United States)

    Copenhaver, Jason L. (Inventor); Jeremy, Ramos (Inventor); Wolfe, Jeffrey M. (Inventor); Brenner, Dean (Inventor)

    2010-01-01

    A method and system for adapting fault tolerant computing. The method includes the steps of measuring an environmental condition representative of an environment. An on-board processing system's sensitivity to the measured environmental condition is measured. It is determined whether to reconfigure a fault tolerance of the on-board processing system based in part on the measured environmental condition. The fault tolerance of the on-board processing system may be reconfigured based in part on the measured environmental condition.

  3. An electron microscopy based method for the detection and quantification of nanomaterial number concentration in environmentally relevant media

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, A. [School of Geography, Earth and Environmental Sciences, College of Life and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lead, J.R., E-mail: jlead@mailbox.sc.edu [School of Geography, Earth and Environmental Sciences, College of Life and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Center for Environmental Nanoscience and Risk, Department of Environmental Health Sciences, Arnold School of Public Health, University South Carolina, Columbia 29208, SC (United States); Baalousha, M., E-mail: mbaalous@mailbox.sc.edu [Center for Environmental Nanoscience and Risk, Department of Environmental Health Sciences, Arnold School of Public Health, University South Carolina, Columbia 29208, SC (United States)

    2015-12-15

    Improved detection and characterization of nanomaterials (NMs) in complex environmental media requires the development of novel sampling approaches to improve the detection limit to be close to environmentally realistic concentrations. Transmission electron microscopy (TEM) is an indispensable metrological tool in nanotechnology and environmental nanoscience due to its high spatial resolution and analytical capabilities when coupled to spectroscopic techniques. However, these capabilities are hampered by the conventional sample preparation methods, which suffer from low NM recovery. The current work presents a validated, fully quantitative sampling technique for TEM that overcomes conventional sample preparation shortcomings, and thus enables the use of TEM for measurement of particle number concentration and their detection in complex media at environmentally realistic concentrations. This sampling method is based on ultracentrifugation of NMs from suspension onto a poly-L-lysine (PLL) functionalized TEM grid, using active deposition (by ultracentrifugation) and retention (by PLL interactions with NM surface) of NMs on the substrate, enabling fully quantitative analysis. Similar analysis with AFM was satisfactory in simple media but the lack of chemical-selectivity of AFM limits its applicability for the detection of NMs in complex environmental samples. The sampling approach was validated using both citrate- and PVP-coated AuNMs in pure water, which demonstrated an even distribution of NM on the TEM grid and high NM recovery (80–100%) at environmentally relevant NM concentrations (ca. 0.20–100 μg L{sup −1}). The applicability of the sampling method to complex environmental samples was demonstrated by the quantification of particle number concentration of AuNMs in EPA soft water (with and without Suwannee River fulvic acid) and lake water. This sample preparation approach is also applicable to other types of NMs with some modifications (e.g. centrifugation

  4. An electron microscopy based method for the detection and quantification of nanomaterial number concentration in environmentally relevant media

    International Nuclear Information System (INIS)

    Prasad, A.; Lead, J.R.; Baalousha, M.

    2015-01-01

    Improved detection and characterization of nanomaterials (NMs) in complex environmental media requires the development of novel sampling approaches to improve the detection limit to be close to environmentally realistic concentrations. Transmission electron microscopy (TEM) is an indispensable metrological tool in nanotechnology and environmental nanoscience due to its high spatial resolution and analytical capabilities when coupled to spectroscopic techniques. However, these capabilities are hampered by the conventional sample preparation methods, which suffer from low NM recovery. The current work presents a validated, fully quantitative sampling technique for TEM that overcomes conventional sample preparation shortcomings, and thus enables the use of TEM for measurement of particle number concentration and their detection in complex media at environmentally realistic concentrations. This sampling method is based on ultracentrifugation of NMs from suspension onto a poly-L-lysine (PLL) functionalized TEM grid, using active deposition (by ultracentrifugation) and retention (by PLL interactions with NM surface) of NMs on the substrate, enabling fully quantitative analysis. Similar analysis with AFM was satisfactory in simple media but the lack of chemical-selectivity of AFM limits its applicability for the detection of NMs in complex environmental samples. The sampling approach was validated using both citrate- and PVP-coated AuNMs in pure water, which demonstrated an even distribution of NM on the TEM grid and high NM recovery (80–100%) at environmentally relevant NM concentrations (ca. 0.20–100 μg L"−"1). The applicability of the sampling method to complex environmental samples was demonstrated by the quantification of particle number concentration of AuNMs in EPA soft water (with and without Suwannee River fulvic acid) and lake water. This sample preparation approach is also applicable to other types of NMs with some modifications (e.g. centrifugation

  5. Analytical methods applied to the study of lattice gauge and spin theories

    International Nuclear Information System (INIS)

    Moreo, Adriana.

    1985-01-01

    A study of interactions between quarks and gluons is presented. Certain difficulties of the quantum chromodynamics to explain the behaviour of quarks has given origin to the technique of lattice gauge theories. First the phase diagrams of the discrete space-time theories are studied. The analysis of the phase diagrams is made by numerical and analytical methods. The following items were investigated and studied: a) A variational technique was proposed to obtain very accurated values for the ground and first excited state energy of the analyzed theory; b) A mean-field-like approximation for lattice spin models in the link formulation which is a generalization of the mean-plaquette technique was developed; c) A new method to study lattice gauge theories at finite temperature was proposed. For the first time, a non-abelian model was studied with analytical methods; d) An abelian lattice gauge theory with fermionic matter at the strong coupling limit was analyzed. Interesting results applicable to non-abelian gauge theories were obtained. (M.E.L.) [es

  6. Selection and authentication of botanical materials for the development of analytical methods.

    Science.gov (United States)

    Applequist, Wendy L; Miller, James S

    2013-05-01

    Herbal products, for example botanical dietary supplements, are widely used. Analytical methods are needed to ensure that botanical ingredients used in commercial products are correctly identified and that research materials are of adequate quality and are sufficiently characterized to enable research to be interpreted and replicated. Adulteration of botanical material in commerce is common for some species. The development of analytical methods for specific botanicals, and accurate reporting of research results, depend critically on correct identification of test materials. Conscious efforts must therefore be made to ensure that the botanical identity of test materials is rigorously confirmed and documented through preservation of vouchers, and that their geographic origin and handling are appropriate. Use of material with an associated herbarium voucher that can be botanically identified is always ideal. Indirect methods of authenticating bulk material in commerce, for example use of organoleptic, anatomical, chemical, or molecular characteristics, are not always acceptable for the chemist's purposes. Familiarity with botanical and pharmacognostic literature is necessary to determine what potential adulterants exist and how they may be distinguished.

  7. Integrative Mixed Methods Data Analytic Strategies in Research on School Success in Challenging Circumstances

    Science.gov (United States)

    Jang, Eunice E.; McDougall, Douglas E.; Pollon, Dawn; Herbert, Monique; Russell, Pia

    2008-01-01

    There are both conceptual and practical challenges in dealing with data from mixed methods research studies. There is a need for discussion about various integrative strategies for mixed methods data analyses. This article illustrates integrative analytic strategies for a mixed methods study focusing on improving urban schools facing challenging…

  8. Environmental report 1994. Volume No. 2

    International Nuclear Information System (INIS)

    Rath, K.S.; Harrach, R.J.; Gallegos, G.M.; Failor, R.A.; Christofferson, E.

    1995-01-01

    This volume 2 of the Lawrence Livermore National Laboratory's (LLNL's) annual Environmental Report 1994 is a detailed data report that provides individual data points, where applicable, along with some summary data and more detailed accounts of sample collection and analytical methods. Six chapters have information on monitoring of air, surface water, groundwater, soil and sediment, vegetation and foodstuffs, and environmental radiation; two other chapters cover compliance sel-monitoring and quality assurance

  9. Quality Control Guidelines for SAM Biotoxin Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the pathogen methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  10. Quality Control Guidelines for SAM Radiochemical Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the radiochemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  11. Quality Control Guidelines for SAM Pathogen Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the biotoxin methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  12. Quality Control Guidelines for SAM Chemical Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the chemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  13. A nonlinear analytic function expansion nodal method for transient calculations

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Han Gyn; Park, Sang Yoon; Cho, Byung Oh; Zee, Sung Quun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-12-31

    The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation of the solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized, In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of application to the NEACRP PWR rod ejection benchmark problems. 6 refs., 2 figs., 1 tab. (Author)

  14. A nonlinear analytic function expansion nodal method for transient calculations

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Han Gyn; Park, Sang Yoon; Cho, Byung Oh; Zee, Sung Quun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation of the solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized, In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of application to the NEACRP PWR rod ejection benchmark problems. 6 refs., 2 figs., 1 tab. (Author)

  15. The application of the analytic hierarchy process (AHP) in uranium mine mining method of the optimal selection

    International Nuclear Information System (INIS)

    Tan Zhongyin; Kuang Zhengping; Qiu Huiyuan

    2014-01-01

    Analytic hierarchy process, AHP, is a combination of qualitative and quantitative, systematic and hierarchical analysis method. Basic decision theory of analytic hierarchy process is applied in this article, with a project example in north Guangdong region as the research object, the in-situ mining method optimization choose hierarchical analysis model is established and the analysis method, The results show that, the AHP model for mining method selecting model was reliable, optimization results were conformity with the actual use of the in-situ mining method, and it has better practicability. (authors)

  16. Aspects of investigating scrambling in the synthesis of porphyrins Different analytical methods

    DEFF Research Database (Denmark)

    Nielsen, C.B.; Krebs, Frederik C

    2005-01-01

    Herein, we discuss the analyses and quantification of the different components in porphyrin mixtures, prepared from p-anisaidehyde, p-tolualdehyde, and 5-(4-bromophenyl)-dipyrromethane with acid catalysis, using NMR and HPLC. The advantages and disadvantages of these analytical methods are emphas...

  17. Analytical method validation for quality control and the study of the 50 mg Propylthiouracil stability

    International Nuclear Information System (INIS)

    Valdes Bendoyro, Maria Olga; Garcia Penna, Caridad Margarita; Fernandez, Juan Lugones; Garcia Borges, Lisandra; Martinez Espinosa, Vivian

    2010-01-01

    A high-performance liquid chromatography analytical method was developed and validated for the quality control and stability studies of 50 mg Propylthiouracil tablets. Method is based in active principle separation through a 100 RP-18 RP-18 (5 μm) (250 x 4 mm) Lichrospher chromatography with UV detection to 272 nm, using a mobile phase composed by a ungaseous mixture of a 0.025 M buffer solution-monobasic potassium phosphate to pH= 4,6 ad acetonitrile in a 80:20 ratio with a flux speed of 0,5 mL/min. Analytical method was linear, precise, specific and exact in the study concentrations interval

  18. Comparison of the acetyl bromide spectrophotometric method with other analytical lignin methods for determining lignin concentration in forage samples.

    Science.gov (United States)

    Fukushima, Romualdo S; Hatfield, Ronald D

    2004-06-16

    Present analytical methods to quantify lignin in herbaceous plants are not totally satisfactory. A spectrophotometric method, acetyl bromide soluble lignin (ABSL), has been employed to determine lignin concentration in a range of plant materials. In this work, lignin extracted with acidic dioxane was used to develop standard curves and to calculate the derived linear regression equation (slope equals absorptivity value or extinction coefficient) for determining the lignin concentration of respective cell wall samples. This procedure yielded lignin values that were different from those obtained with Klason lignin, acid detergent acid insoluble lignin, or permanganate lignin procedures. Correlations with in vitro dry matter or cell wall digestibility of samples were highest with data from the spectrophotometric technique. The ABSL method employing as standard lignin extracted with acidic dioxane has the potential to be employed as an analytical method to determine lignin concentration in a range of forage materials. It may be useful in developing a quick and easy method to predict in vitro digestibility on the basis of the total lignin content of a sample.

  19. Pyrrolizidine alkaloids in honey: comparison of analytical methods.

    Science.gov (United States)

    Kempf, M; Wittig, M; Reinhard, A; von der Ohe, K; Blacquière, T; Raezke, K-P; Michel, R; Schreier, P; Beuerle, T

    2011-03-01

    Pyrrolizidine alkaloids (PAs) are a structurally diverse group of toxicologically relevant secondary plant metabolites. Currently, two analytical methods are used to determine PA content in honey. To achieve reasonably high sensitivity and selectivity, mass spectrometry detection is demanded. One method is an HPLC-ESI-MS-MS approach, the other a sum parameter method utilising HRGC-EI-MS operated in the selected ion monitoring mode (SIM). To date, no fully validated or standardised method exists to measure the PA content in honey. To establish an LC-MS method, several hundred standard pollen analysis results of raw honey were analysed. Possible PA plants were identified and typical commercially available marker PA-N-oxides (PANOs). Three distinct honey sets were analysed with both methods. Set A consisted of pure Echium honey (61-80% Echium pollen). Echium is an attractive bee plant. It is quite common in all temperate zones worldwide and is one of the major reasons for PA contamination in honey. Although only echimidine/echimidine-N-oxide were available as reference for the LC-MS target approach, the results for both analytical techniques matched very well (n = 8; PA content ranging from 311 to 520 µg kg(-1)). The second batch (B) consisted of a set of randomly picked raw honeys, mostly originating from Eupatorium spp. (0-15%), another common PA plant, usually characterised by the occurrence of lycopsamine-type PA. Again, the results showed good consistency in terms of PA-positive samples and quantification results (n = 8; ranging from 0 to 625 µg kg(-1) retronecine equivalents). The last set (C) was obtained by consciously placing beehives in areas with a high abundance of Jacobaea vulgaris (ragwort) from the Veluwe region (the Netherlands). J. vulgaris increasingly invades countrysides in Central Europe, especially areas with reduced farming or sites with natural restorations. Honey from two seasons (2007 and 2008) was sampled. While only trace amounts of

  20. Solvent effects in time-dependent self-consistent field methods. II. Variational formulations and analytical gradients

    International Nuclear Information System (INIS)

    Bjorgaard, J. A.; Velizhanin, K. A.; Tretiak, S.

    2015-01-01

    This study describes variational energy expressions and analytical excited state energy gradients for time-dependent self-consistent field methods with polarizable solvent effects. Linear response, vertical excitation, and state-specific solventmodels are examined. Enforcing a variational ground stateenergy expression in the state-specific model is found to reduce it to the vertical excitation model. Variational excited state energy expressions are then provided for the linear response and vertical excitation models and analytical gradients are formulated. Using semiempiricalmodel chemistry, the variational expressions are verified by numerical and analytical differentiation with respect to a static external electric field. Lastly, analytical gradients are further tested by performing microcanonical excited state molecular dynamics with p-nitroaniline

  1. Nuclear methods in environmental and energy research

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, J R [ed.

    1980-01-01

    A total of 75 papers were presented on nuclear methods for analysis of environmental and biological samples. Sessions were devoted to software and mathematical methods; nuclear methods in atmospheric and water research; nuclear and atomic methodology; nuclear methods in biology and medicine; and nuclear methods in energy research.

  2. Nuclear methods in environmental and energy research

    International Nuclear Information System (INIS)

    Vogt, J.R.

    1980-01-01

    A total of 75 papers were presented on nuclear methods for analysis of environmental and biological samples. Sessions were devoted to software and mathematical methods; nuclear methods in atmospheric and water research; nuclear and atomic methodology; nuclear methods in biology and medicine; and nuclear methods in energy research

  3. Role of analytical chemistry in environment and health

    International Nuclear Information System (INIS)

    Kushwaha, H.S.; Puranik, V.D.; Tripathi, R.M.

    2007-01-01

    Analytical chemistry plays an important role in the protection of human health from biological, chemical and radiological hazards in the environment. It is highly useful in the areas of environmental health sciences, such as air pollution, environmental chemistry, environmental management; environmental toxicology, industrial hygiene, and water quality

  4. Validation of three new methods for determination of metal emissions using a modified Environmental Protection Agency Method 301

    Energy Technology Data Exchange (ETDEWEB)

    Catherine A. Yanca; Douglas C. Barth; Krag A. Petterson; Michael P. Nakanishi; John A. Cooper; Bruce E. Johnsen; Richard H. Lambert; Daniel G. Bivins [Cooper Environmental Services, LLC, Portland, OR (United States)

    2006-12-15

    Three new methods applicable to the determination of hazardous metal concentrations in stationary source emissions were developed and evaluated for use in U.S. Environmental Protection Agency (EPA) compliance applications. Two of the three independent methods, a continuous emissions monitor-based method (Xact) and an X-ray-based filter method (XFM), are used to measure metal emissions. The third method involves a quantitative aerosol generator (QAG), which produces a reference aerosol used to evaluate the measurement methods. A modification of EPA Method 301 was used to validate the three methods for As, Cd, Cr, Pb, and Hg, representing three hazardous waste combustor Maximum Achievable Control Technology (MACT) metal categories (low volatile, semivolatile, and volatile). The measurement methods were evaluated at a hazardous waste combustor (HWC) by comparing measured with reference aerosol concentrations. The QAG, Xact, and XFM met the modified Method 301 validation criteria. All three of the methods demonstrated precisions and accuracies on the order of 5%. The measurement methods should be applicable to emissions from a wide range of sources, and the reference aerosol generator should be applicable to additional analytes. EPA recently approved an alternative monitoring petition for an HWC at Eli Lilly's Tippecanoe site in Lafayette, IN, in which the Xact is used for demonstrating compliance with the HWC MACT metal emissions (low volatile, semivolatile, and volatile). The QAG reference aerosol generator was approved as a method for providing a quantitative reference aerosol, which is required for certification and continuing quality assurance of the Xact. 30 refs., 5 figs., 11 tabs.

  5. Nuclear methods in environmental and energy research

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, J. R. [ed.

    1977-01-01

    The topics considered in the seven sessions were nuclear methods in atmospheric research; nuclear and atomic methodology; nuclear methods in tracer applications; energy exploration, production, and utilization; nuclear methods in environmental monitoring; nuclear methods in water research; and nuclear methods in biological research. Individual abstracts were prepared for each paper. (JSR)

  6. Environmental Chemistry Methods (ECM) Index - 0-9

    Science.gov (United States)

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with a number as the first character.

  7. Characterization, thermal stability studies, and analytical method development of Paromomycin for formulation development.

    Science.gov (United States)

    Khan, Wahid; Kumar, Neeraj

    2011-06-01

    Paromomycin (PM) is an aminoglycoside antibiotic, first isolated in the 1950s, and approved in 2006 for treatment of visceral leishmaniasis. Although isolated six decades back, sufficient information essential for development of pharmaceutical formulation is not available for PM. The purpose of this paper was to determine thermal stability and development of new analytical method for formulation development of PM. PM was characterized by thermoanalytical (DSC, TGA, and HSM) and by spectroscopic (FTIR) techniques and these techniques were used to establish thermal stability of PM after heating PM at 100, 110, 120, and 130 °C for 24 h. Biological activity of these heated samples was also determined by microbiological assay. Subsequently, a simple, rapid and sensitive RP-HPLC method for quantitative determination of PM was developed using pre-column derivatization with 9-fluorenylmethyl chloroformate. The developed method was applied to estimate PM quantitatively in two parenteral dosage forms. PM was successfully characterized by various stated techniques. These techniques indicated stability of PM for heating up to 120 °C for 24 h, but when heated at 130 °C, PM is liable to degradation. This degradation is also observed in microbiological assay where PM lost ∼30% of its biological activity when heated at 130 °C for 24 h. New analytical method was developed for PM in the concentration range of 25-200 ng/ml with intra-day and inter-day variability of stability of PM was determined successfully. Developed analytical method was found sensitive, accurate, and precise for quantification of PM. Copyright © 2010 John Wiley & Sons, Ltd. Copyright © 2010 John Wiley & Sons, Ltd.

  8. Validation of analytical method for quality control of B12 Vitamin-10 000 injection

    International Nuclear Information System (INIS)

    Botet Garcia, Martha; Garcia Penna, Caridad Margarita; Troche Concepcion, Yenilen; Cannizares Arencibia, Yanara; Moreno Correoso, Barbara

    2009-01-01

    Analytical method reported by USA Pharmacopeia was validated for quality control of injectable B 1 2 Vitamin (10 000 U) by UV spectrophotometry because this is a simpler and low-cost method allowing quality control of finished product. Calibration curve was graphed at 60 to 140% interval, where it was linear with a correlation coefficient similar to 0, 9999; statistical test for interception and slope was considered non-significant. There was a recovery of 99.7 % in study concentrations interval where the Cochran (G) and Student(t) test were not significant too. Variation coefficient in repetition study was similar to 0.59 % for the 6 assayed replies, whereas in intermediate precision analysis, the Fisher and Student tests were not significant. Analytical method was linear, precise, specific and exact in study concentrations interval

  9. Environmental and process monitoring technologies

    International Nuclear Information System (INIS)

    Vo-Dinh, Tuan

    1993-01-01

    The objective of this conference was to provide a multidisciplinary forum dealing with state-of-the-art methods and instrumentation for environmental and process monitoring. In the last few years, important advances have been made in improving existing analytical methods and developing new techniques for trace detection of chemicals. These monitoring technologies are a topic of great interest for environmental and industrial control in a wide spectrum of areas. Sensitive detection, selective characterization, and cost-effective analysis are among the most important challenges facing monitoring technologies. This conference integrating interdisciplinary research and development was aimed to present the most recent advances and applications in the important areas of environmental and process monitoring. Separate abstracts have been prepared for 34 papers for inclusion in the appropriate data bases

  10. New developments in radiometrics and mass spectrometry methods for radionuclide analysis of environmental samples

    International Nuclear Information System (INIS)

    Povinec, P.P.; LaRosa, J.J.; Lee, S.H.; Wyse, E.

    2002-01-01

    The radionuclide levels observed at present in the environment are very low, therefore high sensitive analytical systems are required for carrying out environmental investigations. One very important recent development in analytical techniques for low-level activity measurements is the production of large volume HPGe detectors (up to 200% relative efficiency to 75 mm diameter x 75 mm long NaI (Tl) crystals). Their high efficiency and excellent energy resolution permit the analyses of various gamma-emitters in composite samples selectively and very often non-destructively (e.g. in sea sediments). However, this technique is restricted to gamma-emitters only (e.g. for 7 Be, 40 K, 54 Mn, 60 Co, 137 Cs, 210 Pb, etc.). Other radionuclides frequently found in the marine environment are the pure beta-emitters, like 3 H, 14 C, 32 Si, 32 P, 90 Sr, 241 Pu, etc., where mainly liquid scintillation counting has made great improvements in recent years. However, for some of these radionuclides mass spectrometry methods represent a real breakthrough in low-level counting, e.g. 3 He in-growth mass spectrometry for 3 H, or accelerator mass spectrometry (AMS) for 14 C

  11. Analytical free energy gradient for the molecular Ornstein-Zernike self-consistent-field method

    Directory of Open Access Journals (Sweden)

    N.Yoshida

    2007-09-01

    Full Text Available An analytical free energy gradient for the molecular Ornstein-Zernike self-consistent-field (MOZ-SCF method is presented. MOZ-SCF theory is one of the theories to considering the solvent effects on the solute electronic structure in solution. [Yoshida N. et al., J. Chem. Phys., 2000, 113, 4974] Molecular geometries of water, formaldehyde, acetonitrile and acetone in water are optimized by analytical energy gradient formula. The results are compared with those from the polarizable continuum model (PCM, the reference interaction site model (RISM-SCF and the three dimensional (3D RISM-SCF.

  12. THE USE OF AHP METHOD FOR THE DETERMINATION OF THE MOST ENVIRONMENTALLY BENEFICIAL VARIANTS OF BARRAGES

    Directory of Open Access Journals (Sweden)

    Justyna Kubicz

    2015-09-01

    Full Text Available This study presents an attempt to apply the AHP (Analytic Hierarchy Process method for the determination of the most beneficial concept of development of a barrage. The main focus of the analysis was the influence of the civil engineering structure on various elements of the environment. The AHP method was applied to analyse the influence of specific scenarios on environmental elements and on the overall objective. Basing on the analysis, local and global priorities were determined for individual elements of the created decision tree, which allowed us to select the most beneficial scenario. The scenarios referred to the existing hydraulic structures located on the rivers Głomia, Gwda and Prosna. In order to verify the obtained results, calculations of the consistency of the importance evaluations for specific criteria were performed.

  13. Shape resonances of Be- and Mg- investigated with the method of analytic continuation

    Science.gov (United States)

    Čurík, Roman; Paidarová, I.; Horáček, J.

    2018-05-01

    The regularized method of analytic continuation is used to study the low-energy negative-ion states of beryllium (configuration 2 s2ɛ p 2P ) and magnesium (configuration 3 s2ɛ p 2P ) atoms. The method applies an additional perturbation potential and requires only routine bound-state multi-electron quantum calculations. Such computations are accessible by most of the free or commercial quantum chemistry software available for atoms and molecules. The perturbation potential is implemented as a spherical Gaussian function with a fixed width. Stability of the analytic continuation technique with respect to the width and with respect to the input range of electron affinities is studied in detail. The computed resonance parameters Er=0.282 eV, Γ =0.316 eV for the 2 p state of Be- and Er=0.188 eV, Γ =0.167 for the 3 p state of Mg- agree well with the best results obtained by much more elaborate and computationally demanding present-day methods.

  14. Laser-induced Breakdown spectroscopy quantitative analysis method via adaptive analytical line selection and relevance vector machine regression model

    International Nuclear Information System (INIS)

    Yang, Jianhong; Yi, Cancan; Xu, Jinwu; Ma, Xianghong

    2015-01-01

    A new LIBS quantitative analysis method based on analytical line adaptive selection and Relevance Vector Machine (RVM) regression model is proposed. First, a scheme of adaptively selecting analytical line is put forward in order to overcome the drawback of high dependency on a priori knowledge. The candidate analytical lines are automatically selected based on the built-in characteristics of spectral lines, such as spectral intensity, wavelength and width at half height. The analytical lines which will be used as input variables of regression model are determined adaptively according to the samples for both training and testing. Second, an LIBS quantitative analysis method based on RVM is presented. The intensities of analytical lines and the elemental concentrations of certified standard samples are used to train the RVM regression model. The predicted elemental concentration analysis results will be given with a form of confidence interval of probabilistic distribution, which is helpful for evaluating the uncertainness contained in the measured spectra. Chromium concentration analysis experiments of 23 certified standard high-alloy steel samples have been carried out. The multiple correlation coefficient of the prediction was up to 98.85%, and the average relative error of the prediction was 4.01%. The experiment results showed that the proposed LIBS quantitative analysis method achieved better prediction accuracy and better modeling robustness compared with the methods based on partial least squares regression, artificial neural network and standard support vector machine. - Highlights: • Both training and testing samples are considered for analytical lines selection. • The analytical lines are auto-selected based on the built-in characteristics of spectral lines. • The new method can achieve better prediction accuracy and modeling robustness. • Model predictions are given with confidence interval of probabilistic distribution

  15. A functional-analytic method for the study of difference equations

    Directory of Open Access Journals (Sweden)

    Panayiotis D. Siafarikas

    2004-07-01

    Full Text Available We will give the generalization of a recently developed functional-analytic method for studying linear and nonlinear, ordinary and partial, difference equations in the ℓp1 and ℓp2 spaces, p∈ℕ, p≥1. The method will be illustrated by use of two examples concerning a nonlinear ordinary difference equation known as the Putnam equation, and a linear partial difference equation of three variables describing the discrete Newton law of cooling in three dimensions.

  16. New analytical methods for quality control of St. John's wort

    International Nuclear Information System (INIS)

    Huck-Pezzei, V.

    2013-01-01

    In the present work, a novel analytical platform is introduced, which enables both anal-ysis and quality control of St. John´s wort extracts and tissue. The synergistic combina-tion of separation techniques (including thin-layer chromatography (TLC), high-performance liquid chromatography (HPLC)) with mass spectrometry (MS) and vibra-tional spectroscopy is demonstrated to get deeper insights into the ingredients composi-tion. TLC was successfully employed to identify some unknown ingredients being pre-sent in samples with Chinese provenience. The here described novel HPLC method allowed to differentiate clearly between European and Chinese samples on one hand, on the other hand this method could successfully be employed for the semi-preparative isolation of the unknown ingredient. Matrix-free laser desorption ionization time of flight mass spectrometry (mf-LDI-TOF/MS) using a special designed titanium oxide layer was employed to identify the structure of the substance. The analytical knowledge generated so far was used to establish an infrared spectroscopic model allowing both quantitative analysis of ingredients as well as differentiating between European and Chinese provenience. Finally, infrared imaging spectroscopy was conducted to get knowledge about the high resolved distribution of ingredients. The analytical platform established can be used for fast and non-destructive quantitation and quality control to identify adulteration being of interest according to the Deutsche Arzneimittel Codex (DAC) even for the phytopharmaceutical industry. (author) [de

  17. Determination of Glucocorticoids in UPLC-MS in Environmental Samples from an Occupational Setting

    Directory of Open Access Journals (Sweden)

    Enrico Oddone

    2015-01-01

    Full Text Available Occupational exposures to glucocorticoids are still a neglected issue in some work environments, including pharmaceutical plants. We developed an analytical method to quantify simultaneously 21 glucocorticoids using UPLC coupled with mass spectrometry to provide a basis to carry out environmental monitoring. Samples were taken from air, hand-washing tests, pad-tests and wipe-tests. This paper reports the contents of the analytical methodology, along with the results of this extensive environmental and personal monitoring of glucocorticoids. The method in UPLC-MS turned out to be suitable and effective for the aim of the study. Wipe-test and pad-test desorption was carried out using 50 mL syringes, a simple technique that saves time without adversely affecting analyte recovery. Results showed a widespread environmental pollution due to glucocorticoids. This is of particular concern. Evaluation of the dose absorbed by each worker and identification of a biomarker for occupational exposure will contribute to assessment and prevention of occupational exposure.

  18. Analytical methods for toxic gases from thermal degradation of polymers

    Science.gov (United States)

    Hsu, M.-T. S.

    1977-01-01

    Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

  19. Analytical methods in sphingolipidomics: Quantitative and profiling approaches in food analysis.

    Science.gov (United States)

    Canela, Núria; Herrero, Pol; Mariné, Sílvia; Nadal, Pedro; Ras, Maria Rosa; Rodríguez, Miguel Ángel; Arola, Lluís

    2016-01-08

    In recent years, sphingolipidomics has emerged as an interesting omic science that encompasses the study of the full sphingolipidome characterization, content, structure and activity in cells, tissues or organisms. Like other omics, it has the potential to impact biomarker discovery, drug development and systems biology knowledge. Concretely, dietary food sphingolipids have gained considerable importance due to their extensively reported bioactivity. Because of the complexity of this lipid family and their diversity among foods, powerful analytical methodologies are needed for their study. The analytical tools developed in the past have been improved with the enormous advances made in recent years in mass spectrometry (MS) and chromatography, which allow the convenient and sensitive identification and quantitation of sphingolipid classes and form the basis of current sphingolipidomics methodologies. In addition, novel hyphenated nuclear magnetic resonance (NMR) strategies, new ionization strategies, and MS imaging are outlined as promising technologies to shape the future of sphingolipid analyses. This review traces the analytical methods of sphingolipidomics in food analysis concerning sample extraction, chromatographic separation, the identification and quantification of sphingolipids by MS and their structural elucidation by NMR. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Functional analytic methods in complex analysis and applications to partial differential equations

    International Nuclear Information System (INIS)

    Mshimba, A.S.A.; Tutschke, W.

    1990-01-01

    The volume contains 24 lectures given at the Workshop on Functional Analytic Methods in Complex Analysis and Applications to Partial Differential Equations held in Trieste, Italy, between 8-19 February 1988, at the ICTP. A separate abstract was prepared for each of these lectures. Refs and figs