WorldWideScience

Sample records for entre doses simples

  1. Modelling simple helically delivered dose distributions

    International Nuclear Information System (INIS)

    Fenwick, John D; Tome, Wolfgang A; Kissick, Michael W; Mackie, T Rock

    2005-01-01

    In a previous paper, we described quality assurance procedures for Hi-Art helical tomotherapy machines. Here, we develop further some ideas discussed briefly in that paper. Simple helically generated dose distributions are modelled, and relationships between these dose distributions and underlying characteristics of Hi-Art treatment systems are elucidated. In particular, we describe the dependence of dose levels along the central axis of a cylinder aligned coaxially with a Hi-Art machine on fan beam width, couch velocity and helical delivery lengths. The impact on these dose levels of angular variations in gantry speed or output per linear accelerator pulse is also explored

  2. AT cells are not radiosensitive for simple chromosomal exchanges at low dose

    International Nuclear Information System (INIS)

    Hada, Megumi; Huff, Janice L.; Patel, Zarana S.; Kawata, Tetsuya; Pluth, Janice M.; George, Kerry A.; Cucinotta, Francis A.

    2011-01-01

    Cells deficient in ATM (product of the gene that is mutated in ataxia telangiectasia patients) or NBS (product of the gene mutated in the Nijmegen breakage syndrome) show increased yields of both simple and complex chromosomal aberrations after high doses (>0.5 Gy) of ionizing radiation (X-rays or γ-rays), however less is known on how these cells respond at low dose. Previously we had shown that the increased chromosome aberrations in ATM and NBS defective lines was due to a significantly larger quadratic dose-response term compared to normal fibroblasts for both simple and complex exchanges. The linear dose-response term for simple exchanges was significantly higher in NBS cells compared to wild type cells, but not for AT cells. However, AT cells have a high background level of exchanges compared to wild type or NBS cells that confounds the understanding of low dose responses. To understand the sensitivity differences for high to low doses, chromosomal aberration analysis was first performed at low dose-rates (0.5 Gy/d), and results provided further evidence for the lack of sensitivity for exchanges in AT cells below doses of 1 Gy. Normal lung fibroblast cells treated with KU-55933, a specific ATM kinase inhibitor, showed increased numbers of exchanges at a dose of 1 Gy and higher, but were similar to wild type cells at 0.5 Gy or below. These results were confirmed using siRNA knockdown of ATM. The present study provides evidence that the increased radiation sensitivity of AT cells for chromosomal exchanges found at high dose does not occur at low dose.

  3. A simple formula for depth dose calculation for Co-60 teletherapy beam dosimetry

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1979-01-01

    Knowledge of dose at all points of interest in the plane of tumour is essential for treatment planning. A very simple formula for scatter dose calculation along the central axis of a Co-60 beam has been derived. This formula uses primary dose at depth d, scatter air ratio at the depth of maximum ionisation and the effective depth of the volume, irradiating the medium. The method for calculation of percentage depth dose at any point in the principal plane has been explained in detail. The simple form of the formulation will help in improving the treatment plans for treatments of lesions using Co-60 teletherapy machines. (orig.) [de

  4. Influence of dose rate on the induction of simple and complex chromosome exchanges by gamma rays.

    Science.gov (United States)

    Loucas, Bradford D; Eberle, Richard; Bailey, Susan M; Cornforth, Michael N

    2004-10-01

    Single-color painting of whole chromosomes, or protocols in which only a few chromosomes are distinctively painted, will always fail to detect a proportion of complex exchanges because they frequently produce pseudosimple painting patterns that are indistinguishable from those produced by bona fide simple exchanges. When 24-color multi-fluor FISH (mFISH) was employed for the purpose of distinguishing (truly) simple from pseudosimple exchanges, it was confirmed that the acute low-LET radiation dose-response relationship for simple exchanges lacked significant upward curvature. This result has been interpreted to indicate that the formation of simple exchanges requires only one chromosome locus be damaged (e.g. broken) by radiation to initiate an exchange-not two, as classical cytogenetic theory maintains. Because a one-lesion mechanism implies single-track action, it follows that the production of simple exchanges should not be influenced by changes in dose rate. To examine this prediction, we irradiated noncycling primary human fibroblasts with graded doses of (137)Cs gamma rays at an acute dose rate of 1.10 Gy/min and compared, using mFISH, the yield of simple exchanges to that observed after exposure to the same radiation delivered at a chronic dose rate of 0.08 cGy/min. The shape of the dose response was found to be quasi-linear for both dose rates, but, counter to providing support for a one-lesion mechanism, the yield of simple aberrations was greatly reduced by protracted exposure. Although chronic doses were delivered at rates low enough to produce damage exclusively by single-track action, this did not altogether eliminate the formation of complex aberrations, an analysis of which leads to the conclusion that a single track of low-LET radiation is capable of inducing complex exchanges requiring up to four proximate breaks for their formation. For acute exposures, the ratio of simple reciprocal translocations to simple dicentrics was near unity.

  5. Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A. [Department of Radiological Sciences, St Jude Children' s Research Hospital, Memphis, Tennessee 38105 (United States); Mirro, Amy E. [Department of Biomedical Engineering, Washington University, St Louis, Missouri 63130 (United States)

    2014-07-15

    Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. The CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to

  6. A Novel Simple Phantom for Verifying the Dose of Radiation Therapy

    Directory of Open Access Journals (Sweden)

    J. H. Lee

    2015-01-01

    Full Text Available A standard protocol of dosimetric measurements is used by the organizations responsible for verifying that the doses delivered in radiation-therapy institutions are within authorized limits. This study evaluated a self-designed simple auditing phantom for use in verifying the dose of radiation therapy; the phantom design, dose audit system, and clinical tests are described. Thermoluminescent dosimeters (TLDs were used as postal dosimeters, and mailable phantoms were produced for use in postal audits. Correction factors are important for converting TLD readout values from phantoms into the absorbed dose in water. The phantom scatter correction factor was used to quantify the difference in the scattered dose between a solid water phantom and homemade phantoms; its value ranged from 1.084 to 1.031. The energy-dependence correction factor was used to compare the TLD readout of the unit dose irradiated by audit beam energies with 60Co in the solid water phantom; its value was 0.99 to 1.01. The setup-condition factor was used to correct for differences in dose-output calibration conditions. Clinical tests of the device calibrating the dose output revealed that the dose deviation was within 3%. Therefore, our homemade phantoms and dosimetric system can be applied for accurately verifying the doses applied in radiation-therapy institutions.

  7. Simple experimentally derived algorithm for computer calculated dose rates associated with 137Cs gynecologic insertions

    International Nuclear Information System (INIS)

    Wrede, D.E.; Dawalibi, H.

    1980-01-01

    A simple mathematical algorithm is derived from experimental data for dose rates from 137 Cs sources in a finite tissue equivalent medium corresponding to the female pelvis. An analytical expression for a point source of 137 Cs along with a simple numerical integration routine allows for rapid as well as accurate dose rate calculations at points of interest for gynecologic insertions. When compared with theoretical models assuming an infinite unit density medium, the measured dose rates are found to be systematically lower at distances away from a single source; 5 per cent at 2 cm and 10 per cent at 7 cm along the transverse axis. Allowance in the program for print out of dose rates from individual sources to a given point and the feature of source strength modification allows for optimization in terms of increasing the difference in dose rate between reference treatment points and sensitive structures such as the bladder, rectum and colon. (Auth.)

  8. Simple experimentally derived algorithm for computer calculated dose rates associated with /sup 137/Cs gynecologic insertions

    Energy Technology Data Exchange (ETDEWEB)

    Wrede, D E; Dawalibi, H [King Faisal Specialist Hospital and Research Centre, Department of Medical Physics. Riyadh (Saudi Arabia)

    1980-01-01

    A simple mathematical algorithm is derived from experimental data for dose rates from /sup 137/Cs sources in a finite tissue equivalent medium corresponding to the female pelvis. An analytical expression for a point source of /sup 137/Cs along with a simple numerical integration routine allows for rapid as well as accurate dose rate calculations at points of interest for gynecologic insertions. When compared with theoretical models assuming an infinite unit density medium, the measured dose rates are found to be systematically lower at distances away from a single source; 5 per cent at 2 cm and 10 per cent at 7 cm along the transverse axis. Allowance in the program for print out of dose rates from individual sources to a given point and the feature of source strength modification allows for optimization in terms of increasing the difference in dose rate between reference treatment points and sensitive structures such as the bladder, rectum and colon.

  9. Simple approximation for estimating centerline gamma absorbed dose rates due to a continuous Gaussian plume

    International Nuclear Information System (INIS)

    Overcamp, T.J.; Fjeld, R.A.

    1987-01-01

    A simple approximation for estimating the centerline gamma absorbed dose rates due to a continuous Gaussian plume was developed. To simplify the integration of the dose integral, this approach makes use of the Gaussian cloud concentration distribution. The solution is expressed in terms of the I1 and I2 integrals which were developed for estimating long-term dose due to a sector-averaged Gaussian plume. Estimates of tissue absorbed dose rates for the new approach and for the uniform cloud model were compared to numerical integration of the dose integral over a Gaussian plume distribution

  10. A simple method for conversion of airborne gamma-ray spectra to ground level doses

    DEFF Research Database (Denmark)

    Korsbech, Uffe C C; Bargholz, Kim

    1996-01-01

    A new and simple method for conversion of airborne NaI(Tl) gamma-ray spectra to dose rates at ground level has been developed. By weighting the channel count rates with the channel numbers a spectrum dose index (SDI) is calculated for each spectrum. Ground level dose rates then are determined...... by multiplying the SDI by an altitude dependent conversion factor. The conversion factors are determined from spectra based on Monte Carlo calculations. The results are compared with measurements in a laboratory calibration set-up. IT-NT-27. June 1996. 27 p....

  11. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    Science.gov (United States)

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  12. Fractional poisson--a simple dose-response model for human norovirus.

    Science.gov (United States)

    Messner, Michael J; Berger, Philip; Nappier, Sharon P

    2014-10-01

    This study utilizes old and new Norovirus (NoV) human challenge data to model the dose-response relationship for human NoV infection. The combined data set is used to update estimates from a previously published beta-Poisson dose-response model that includes parameters for virus aggregation and for a beta-distribution that describes variable susceptibility among hosts. The quality of the beta-Poisson model is examined and a simpler model is proposed. The new model (fractional Poisson) characterizes hosts as either perfectly susceptible or perfectly immune, requiring a single parameter (the fraction of perfectly susceptible hosts) in place of the two-parameter beta-distribution. A second parameter is included to account for virus aggregation in the same fashion as it is added to the beta-Poisson model. Infection probability is simply the product of the probability of nonzero exposure (at least one virus or aggregate is ingested) and the fraction of susceptible hosts. The model is computationally simple and appears to be well suited to the data from the NoV human challenge studies. The model's deviance is similar to that of the beta-Poisson, but with one parameter, rather than two. As a result, the Akaike information criterion favors the fractional Poisson over the beta-Poisson model. At low, environmentally relevant exposure levels (Poisson model; however, caution is advised because no subjects were challenged at such a low dose. New low-dose data would be of great value to further clarify the NoV dose-response relationship and to support improved risk assessment for environmentally relevant exposures. © 2014 Society for Risk Analysis Published 2014. This article is a U.S. Government work and is in the public domain for the U.S.A.

  13. Quality assurance for high dose rate brachytherapy treatment planning optimization: using a simple optimization to verify a complex optimization

    International Nuclear Information System (INIS)

    Deufel, Christopher L; Furutani, Keith M

    2014-01-01

    As dose optimization for high dose rate brachytherapy becomes more complex, it becomes increasingly important to have a means of verifying that optimization results are reasonable. A method is presented for using a simple optimization as quality assurance for the more complex optimization algorithms typically found in commercial brachytherapy treatment planning systems. Quality assurance tests may be performed during commissioning, at regular intervals, and/or on a patient specific basis. A simple optimization method is provided that optimizes conformal target coverage using an exact, variance-based, algebraic approach. Metrics such as dose volume histogram, conformality index, and total reference air kerma agree closely between simple and complex optimizations for breast, cervix, prostate, and planar applicators. The simple optimization is shown to be a sensitive measure for identifying failures in a commercial treatment planning system that are possibly due to operator error or weaknesses in planning system optimization algorithms. Results from the simple optimization are surprisingly similar to the results from a more complex, commercial optimization for several clinical applications. This suggests that there are only modest gains to be made from making brachytherapy optimization more complex. The improvements expected from sophisticated linear optimizations, such as PARETO methods, will largely be in making systems more user friendly and efficient, rather than in finding dramatically better source strength distributions. (paper)

  14. Endostatin (EntreMed).

    Science.gov (United States)

    Grosios, K

    2000-07-01

    EntreMed has licensed the worldwide rights to the angiogenesis inhibitor Endostatin, a 20 kDa C-terminal fragment of collagen XVIII, from the Children's Hospital of Boston, a teaching affiliate of Harvard Medical School. It is being developed as a potential cancer treatment and may also be useful in certain types of blindness and arthritis [227427]. EntreMed filed an IND for Endostatin in June 1999 [334125] and as of September 1999, phase I trials were underway [341462]. As of April 2000, the company had initiated plans for testing low doses of Endostatin in cancer patients using continuous infusion and sc administration in a further phase I study to be conducted in Europe [361594]. A phase I trial of Endostatin which will evaluate the safety and efficacy of Endostatin at a range of doses in no more than 100 cancer patients has been initiated. The trial will take place at the University of Texas MD Anderson Medical Center and the University of Wisconsin Cancer Center in Madison. The National Cancer Center will be sponsoring the trial, which is expected to be completed in late 2000. As of March 2000, there had been no serious adverse events attributable to Endostatin administration. The first report from this trial is expected in autumn 2000 [341462], [366312]. The mechanism of action for Endostatin remains unclear, although reports from the 91st AACR Meeting in April 2000 showed that recombinant human endostatin bound to a number of tropomyosin cDNAs in a library screen [362039]. In preclinical studies, repeated administration of Endostatin consistently shrank primary tumors and did not produce any drug resistance. In mice, a variety of tumors which had progressed to 1 to 2% of total body weight, regressed to microscopic, dormant lesions following Endostatin treatment [231418], [231470], [270673]. Types of cancers which respond to Endostatin include lung, skin, vascular and fibrosarcomas. Toxicology studies in cynomolgus monkeys showed that bolus injections of

  15. Indução do Parto com Misoprostol: Comparação entre duas Doses Labor Induction with Misoprostol: Comparison of Two Dose Regimens

    Directory of Open Access Journals (Sweden)

    Dimas Augusto Carvalho de Araújo

    1999-10-01

    Full Text Available Objetivo: comparar a eficácia e segurança entre duas doses de misoprostol administradas por via vaginal para amadurecimento cervical e indução do parto. Pacientes e Métodos: sessenta e uma pacientes com indicação médica para indução do parto e colo desfavorável foram incluídas neste estudo. Vinte e oito pacientes receberam 25 µg e trinta e três 50 µg de misoprostol, a intervalos de 4 horas, até um período máximo de 24 horas. Resultados: a rotura prematura de membranas, gestação prolongada e doença hipertensiva específica da gestação foram as principais indicações para a indução do parto. O intervalo de tempo, em minutos, entre inserção do misoprostol até o parto vaginal foi similar nos grupos de 25 µg (416,3 ± 148,1 e 50 µg (425 ± 135,9. A porcentagem de parto vaginal foi de 82,2% e 81,9% nos grupos de 25 e 50 µg, respectivamente. Não houve diferença significativa entre os grupos no que se refere a complicações maternas e fetais. Conclusões: a administração de misoprostol por via vaginal mostrou-se um método eficiente e seguro para o amadurecimento cervical e indução do parto. A dose de 25 µg mostrou ter eficácia e segurança comparável à de 50 µg.Purpose: to compare the efficacy and safety between two doses of intravaginal misoprostol for cervical ripening and induction of labor. Patients and Methods: sixty-one patients with medical indication for induction of labor and unfavorable cervix were included in this study. Twenty-eight of them received 25 µg and thirty-three 50 µg misoprostol, every four hours until delivery. Results: premature rupture of membranes, prolonged gestation and preeclampsia were the main indications for labor induction. The time interval, in minutes, from insertion of misoprostol until delivery was similar for the 25 µg (416.3 ± 148.1 and 50 µg (425.0 ± 135.9 groups. The percentage of vaginal delivery was 82.2% and 81.9% in the groups of 25µg and 50 µg

  16. JISCARD GUI, a graphical interface application for simple and quick calculation of aviation route doses

    International Nuclear Information System (INIS)

    Andersson, Martin; Ryufuku, Susumu; Yasuda, Hiroshi

    2011-01-01

    Pilots, flight attendants, and passengers aboard jet aircrafts are subjected to higher cosmic radiation levels at high altitude than on the ground. Additional dose, received during flight is called 'aviation route dose'. Addressing the needs for precise and easy determination of aviation route doses (Sv), the authors have developed a new application 'JISCARD GUI' with a graphical user interface which provides dose rate (Sv/h) distribution along a flight route and aviation route dose. The graphical interface made with Adobe Flash provide functions to select airports on dynamic map or to search by airport/city names, and to report resulting aviation route doses and graphs of dose rate change through a flight. Dose rate data at several cut off rigidity, Rc and force field potential, FFP were calculated in advance using a PHITS-based analytical model and stored in the server as matrix data. Upon user's request of departure/arrival airports and flight date, interpolation using matrix data substantiates derivation of dose rate distribution in a simple and quick manner with sufficient accuracy. Precision of the dose calculation was verified by comparison with JISCARD EX (MS-Excel version) released in September 2008. This advanced application will be open to public through the website of the National Institute of Radiological Sciences in the near future. (author)

  17. Differences of the efficacy values in simple temporary numerical inequality between loser teams in male and female waterpolo Diferencias de los valores de eficacia en desigualdad numérica temporal simple entre equipos perdedores en waterpolo masculino y femenino

    Directory of Open Access Journals (Sweden)

    J. I. Alonso

    2010-09-01

    Full Text Available With this study has intended to obtain two objectives: the first one, to investigate the efficacy values in the playing microsituations in simple temporary numerical inequality with or without ball possession, and the second, to analyze the relation between these and the condition of loser at the end of the match and in both sexes. For the empirical part were recorded in video all the matches of the X Water polo World Championship celebrated in Barcelona during the month of July of 2003, for its subsequent analysis arrived at by consensus between two specialists previously coached, continuing the guidelines of the observational methodology. Valued themselves, by means of some coefficients, the efficacy in all the playing microsituations in simple temporary numerical inequality with or without ball possession obtaining some efficacy values. In the condition of loser at the end of the match differences were revealed among both sexes in the coefficient of shots exactness without possession (.008; taking as reference a value of p <.05. To conclude, to affirm that in one of the fourteen coefficients of efficacy proposed for evaluate the playing microsituations in simple temporary numerical inequality with or without ball possession in water polo are significant differences among sexes in teams with the condition of loser at the end of the match.
    Key words: water polo, efficacy, loser, simple temporary numerical inequality.

    Con este estudio se ha pretendido conseguir dos objetivos: el primero, indagar en los valores de eficacia en las microsituaciones de juego en desigualdad numérica temporal simple con o sin posesión del balón, y el segundo, analizar la relación entre los valores de eficacia en equipos con la condición de perdedor al finalizar el partido y en ambos sexos. Para la parte empírica se filmaron en vídeo todos los partidos de waterpolo del X

  18. Reconstructing Organophosphorus Pesticide Doses Using the Reversed Dosimetry Approach in a Simple Physiologically-Based Pharmacokinetic Model

    Directory of Open Access Journals (Sweden)

    Chensheng Lu

    2012-01-01

    Full Text Available We illustrated the development of a simple pharmacokinetic (SPK model aiming to estimate the absorbed chlorpyrifos doses using urinary biomarker data, 3,5,6-trichlorpyridinol as the model input. The effectiveness of the SPK model in the pesticide risk assessment was evaluated by comparing dose estimates using different urinary composite data. The dose estimates resulting from the first morning voids appeared to be lower than but not significantly different to those using before bedtime, lunch or dinner voids. We found similar trend for dose estimates using three different urinary composite data. However, the dose estimates using the SPK model for individual children were significantly higher than those from the conventional physiologically based pharmacokinetic (PBPK modeling using aggregate environmental measurements of chlorpyrifos as the model inputs. The use of urinary data in the SPK model intuitively provided a plausible alternative to the conventional PBPK model in reconstructing the absorbed chlorpyrifos dose.

  19. SHINE-III. Simple code for skyshine dose calculation up to 3 GeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Tsukiyama, Toshihisa; Tayama, Ryuichi; Handa, Hiroyuki [Hitachi Engineering Co. Ltd., Ibaraki (Japan)] [and others

    2000-03-01

    Skyshine dose at site boundary is considered as one of the most fundamental issues to get approval of constructing nuclear installations. Skyshine conical beam response functions (CBRF) for high energy neutrons up to 3 GeV are obtained using NMTC-JAERI and MCNP code. This CBRF is fitted to the four parameters equation. Simple code named SHINE-III using this equation with updated data is developed. (author)

  20. A simple calculation for the determination of organ or tissue dose from medical x-ray diagnosis for stomach and chest

    International Nuclear Information System (INIS)

    Nishizawa, Kanae

    1984-01-01

    A simple calculation method has been developed to determine the organ or tissue doses of patients for typical X-ray diagnoses. The absorbed doses related to radiation-induced stochastic effects were calculated based on the dosimetric parameters experimentally determined and technical parameters for X-ray diagnostic examinations. The present method is principally based on the TRA method for the beam therapy. The dosimetric parameters such as percentage depth-dose curves and isodose curves were measured with ionization chambers in the MixDP phantom. The distance from the incident surface of X-ray beams to the organ or tissue of interest was determined with a mathematical phantom, which was the modified version of the MIRD phantom for the average Japanese adult. The absorbed doses were determined with a simple table look-up method using a computer. The calculated doses were tabulated for various technical parameters of stomach and chest X-ray examinations. The present calculation was applied to the Rando woman phantom to compare with the phantom measurements. The calculated values agree with the experimental doses within 20% discrepancy. It was concluded that the present calculation method can determine organ or tissue doses very simply for various X-ray examinations and that it was valuable for the estimation of population doses and risks from X-ray diagnoses. (author)

  1. Diversidade genética estimada com marcadores entre sequências simples repetidas em cultivos comerciais de Cupuaçuzeiro

    Directory of Open Access Journals (Sweden)

    Bruna Mezzalira da Silva

    2016-01-01

    Full Text Available RESUMO: Quinze primers ISSR (entre sequências simples repetidas foram utilizados para avaliar a diversidade genética entre e dentro de pomares comerciais de Theobroma grandiflorum (Willd. ex Spreng. K. Schum. Para isso, foram analisados sessenta indivíduos, distribuídos nos três cultivos. Um total de 102 bandas foi amplificado, com uma porcentagem de 52,0% de polimorfismo em nível de espécie e média de 6,8 alelos por primer ISSR. A média do Índice de Conteúdo Polimórfico (PIC foi de 0,55. Em relação aos índices de diversidade gênica de Nei (H e de Shannon (I, os cultivos analisados apresentaram os valores: SAR H = 0,114 e I = 0,177; SSL H = 0,108 e I = 0,162 e SEC H = 0,104 e I = 0,156, considerados valores de moderados a baixos. A AMOVA revelou 34,91% da variância total entre os cultivos e 65,09% dentro deles. Os marcadores moleculares ISSR revelaram que há diversidade genética dentro de cada cultivo comercial estudado, portanto é possível selecionar genótipos superiores que poderão ser utilizados para originar cultivos mais uniformes. Esse resultado tem sido considerado de grande relevância, por fornecer ferramentas para a implementação de programas de melhoramento e delineamento de estratégias de conservação ex situ e in situ.

  2. Simple pulmonary eosinophilia detected at low-dose CT for lung cancer screening

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Kyung Nyeo; Bae, Kyung Soo; Kim, Ho Cheol [Gyeongsang National University Hospital, Jinju (Korea, Republic of)] (and others)

    2006-05-15

    The aim of this study was to evaluate the frequency, radiologic findings and clinical significance of the simple pulmonary eosinophilia (SPE) that was diagnosed among the asymptomatic patients who underwent low-dose CT scans for the early detection of lung cancer. From June 2003 to May 2005, 1,239 asymptomatic patients (1,275 examinations) who visited the health promotion center in our hospital and who underwent low-dose CT were enrolled in this study. SPE was defined as the presence of > 500 eosinophils per microliter of peripheral blood and the presence of abnormal parenchymal lesions such as nodules, airspace consolidation or areas of ground-glass attenuation (GGA) on CT, and there was spontaneous resolution or migration of the lesions on the follow-up examination. We analyzed the CT findings of SPE and we investigated the relationship between the occurrence of SPE and the season, smoking and the presence of parasite infestation. 36 patients were finally diagnosed as having SPE; this was 24% of the 153 patients who were diagnosed with parasite infestation and 2.8% of the total low-dose CT scans. These 36 patients consisted of 31 men and 5 women with a mean age 45.7 years. There was no significant relationship between SPE and the presence of parasite infestation, smoking or gender. Among the patients with peripheral blood eosinophilia, the eosinophil count was significantly higher in the patients with SPE than that in the patients without pulmonary infiltration ({rho} < 0.05). SPE more frequently occurred in winter and spring than in summer and autumn ({rho} < 0.05). The CT findings were single or multiple nodules in 18 patients, nodules and focal GGA in 9 patients and GGA only in 9 patients. Most of the nodules were less than 10 mm (88%, 49/56) in diameter and they showed an ill-defined margin (82%, n = 46); 30% of the nodules (n = 17) showed a halo around them. Simple pulmonary eosinophilia can be suggested as the cause if single or multiple ill-defined nodules

  3. Simple pulmonary eosinophilia detected at low-dose CT for lung cancer screening

    International Nuclear Information System (INIS)

    Jeon, Kyung Nyeo; Bae, Kyung Soo; Kim, Ho Cheol

    2006-01-01

    The aim of this study was to evaluate the frequency, radiologic findings and clinical significance of the simple pulmonary eosinophilia (SPE) that was diagnosed among the asymptomatic patients who underwent low-dose CT scans for the early detection of lung cancer. From June 2003 to May 2005, 1,239 asymptomatic patients (1,275 examinations) who visited the health promotion center in our hospital and who underwent low-dose CT were enrolled in this study. SPE was defined as the presence of > 500 eosinophils per microliter of peripheral blood and the presence of abnormal parenchymal lesions such as nodules, airspace consolidation or areas of ground-glass attenuation (GGA) on CT, and there was spontaneous resolution or migration of the lesions on the follow-up examination. We analyzed the CT findings of SPE and we investigated the relationship between the occurrence of SPE and the season, smoking and the presence of parasite infestation. 36 patients were finally diagnosed as having SPE; this was 24% of the 153 patients who were diagnosed with parasite infestation and 2.8% of the total low-dose CT scans. These 36 patients consisted of 31 men and 5 women with a mean age 45.7 years. There was no significant relationship between SPE and the presence of parasite infestation, smoking or gender. Among the patients with peripheral blood eosinophilia, the eosinophil count was significantly higher in the patients with SPE than that in the patients without pulmonary infiltration (ρ < 0.05). SPE more frequently occurred in winter and spring than in summer and autumn (ρ < 0.05). The CT findings were single or multiple nodules in 18 patients, nodules and focal GGA in 9 patients and GGA only in 9 patients. Most of the nodules were less than 10 mm (88%, 49/56) in diameter and they showed an ill-defined margin (82%, n = 46); 30% of the nodules (n = 17) showed a halo around them. Simple pulmonary eosinophilia can be suggested as the cause if single or multiple ill-defined nodules or

  4. A simple method to back-project isocenter dose of radiotherapy treatments using EPID transit dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, T.B.; Cerbaro, B.Q.; Rosa, L.A.R. da, E-mail: thiago.fisimed@gmail.com, E-mail: tbsilveira@inca.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro - RJ (Brazil)

    2017-07-01

    The aim of this work was to implement a simple algorithm to evaluate isocenter dose in a phantom using the back-projected transmitted dose acquired using an Electronic Portal Imaging Device (EPID) available in a Varian Trilogy accelerator with two nominal 6 and 10 MV photon beams. This algorithm was developed in MATLAB language, to calibrate EPID measured dose in absolute dose, using a deconvolution process, and to incorporate all scattering and attenuation contributions due to photon interactions with phantom. Modeling process was simplified by using empirical curve adjustments to describe the contribution of scattering and attenuation effects. The implemented algorithm and method were validated employing 19 patient treatment plans with 104 clinical irradiation fields projected on the phantom used. Results for EPID absolute dose calibration by deconvolution have showed percent deviations lower than 1%. Final method validation presented average percent deviations between isocenter doses calculated by back-projection and isocenter doses determined with ionization chamber of 1,86% (SD of 1,00%) and -0,94% (SD of 0,61%) for 6 and 10 MV, respectively. Normalized field by field analysis showed deviations smaller than 2% for 89% of all data for 6 MV beams and 94% for 10 MV beams. It was concluded that the proposed algorithm possesses sufficient accuracy to be used for in vivo dosimetry, being sensitive to detect dose delivery errors bigger than 3-4% for conformal and intensity modulated radiation therapy techniques. (author)

  5. Relación entre el herpes simple tipo 2 y las lesiones preinvasivas de cuello uterino

    Directory of Open Access Journals (Sweden)

    Yenddy Carrero

    2006-10-01

    Full Text Available Objetivos: Determinar la presencia y relación del virus herpes simple tipo 2 (VHS-2 en mujeres con diferentes grados de lesiones preinvasivas de cuello uterino. Materiales y métodos: Se estudiaron 176 mujeres con lesiones preinvasivas de cuello uterino y 40 mujeres como grupo control con cuello uterino sano, que asistieron a la consulta ginecológica en diferentes centros de salud, durante los años 2002-2005 en Maracaibo-Venezuela. A las pacientes se les tomó un hisopado del exocervix y una biopsia dirigida del sitio de la lesión por colposcopía. La determinación de VHS-2 se realizó a través de inmunofluorescencia directa. Resultados: La presencia de infección por VHS-2 fue 44 /176 (25%. El mayor número de VHS-2 se obtuvo en las pacientes con grado de lesión tipo NIC II (66,7%. El mayor porcentaje de infección por VHS-2 se determinó en las pacientes que iniciaron sus relaciones sexuales entre los 15 y 20 años (34,5%, las relaciones sexuales diarias (50%, así como relaciones de tipo orogenital fueron consideradas las conductas de mayor riesgo para adquirir la infección. Conclusiones: No se evidenció una relación directa entre VHS-2 y la presencia de cáncer. Los factores de riesgo asociados con la infección son similares a otras ITS, y están ligados con la conducta sexual y hábitos propios del individuo.

  6. SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

    Energy Technology Data Exchange (ETDEWEB)

    Utsunomiya, S; Kushima, N; Katsura, K; Tanabe, S; Hayakawa, T; Sakai, H; Yamada, T; Takahashi, H; Abe, E; Wada, S; Aoyama, H [Niigata University, Niigata (Japan)

    2016-06-15

    Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cm × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.

  7. A simple model to estimate radiation doses to aircrew during air flights in Brazil and abroad

    International Nuclear Information System (INIS)

    Lavalle Heilbron Filho, Paulo Fernando; Pérez Guerrero, Jesus Salvador; Lavalle Heilbron, Rafael Cabidolusso; Amaral, Mario Luth Gonçalves Henriques do

    2015-01-01

    The objective of this article is to present the results obtained from the development of a simple model used to estimate cosmic radiation doses from crew members taking into consideration the variation of the dose rates with the altitude and the latitude, airplane cruise velocity and other important parameters such as, cruise height, takeoff time, landing time, takeoff angle, landing angle. The model was incorporated into a Brazilian computer program developed using the “mathematica” symbolic software. The data used to calculate the dose rates with altitude and latitude by the authors takes into consideration the mean solar activity from January 1958 to December 2008 (51 years). Twenty two data including international and national American flights were used to test the program and the results between them compared, showing good agreement. The program also gives excellent results for the doses expected for the crew members of three Brazilian national flights (between capitals cities in Brazil) when compared with the doses values measured for these flights using a radiation detector. According to the results the doses expected for the Brazilian crews of domestic flights can, in some cases, depending on the number of annual flights, overcome the limit of 1 mSv/year established by the Brazilian competent authority in Brazil (Brazilian Nuclear Energy Commission- CNEN) for public annual exposure. In the case of the simulated international flights the results shows a good agreement with the results found in literature especially when considered the different database series used by the authors and by the other references for the solar activity. (authors)

  8. MO-E-17A-04: Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations

    International Nuclear Information System (INIS)

    Moore, B; Brady, S; Kaufman, R; Mirro, A

    2014-01-01

    Purpose: Investigate the correlation of SSDE with organ dose in a pediatric population. Methods: Four anthropomorphic phantoms, representing a range of pediatric body habitus, were scanned with MOSFET dosimeters placed at 23 organ locations to determine absolute organ dosimetry. Phantom organ dosimetry was divided by phantom SSDE to determine correlation between organ dose and SSDE. Correlation factors were then multiplied by patient SSDE to estimate patient organ dose. Patient demographics consisted of 352 chest and 241 abdominopelvic CT examinations, 22 ± 15 kg (range 5−55 kg) mean weight, and 6 ± 5 years (range 4 mon to 23 years) mean age. Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm. 23 organ correlation factors were determined in the chest and abdominopelvic region across nine pediatric weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7−1.4) and abdominopelvic (average 0.9; range 0.7−1.3) was near unity. For organs that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1−0.4) for both the chest and abdominopelvic regions, respectively. Pediatric organ dosimetry was compared to published values and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusion: Average correlation of SSDE and organ dosimetry was found to be better than ± 10% for fully covered organs within the scan volume. This study provides a list of organ dose correlation factors for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE

  9. MO-E-17A-04: Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, B; Brady, S; Kaufman, R [St Jude Children' s Research Hospital, Memphis, TN (United States); Mirro, A [Washington University, St. Louis, MO (United States)

    2014-06-15

    Purpose: Investigate the correlation of SSDE with organ dose in a pediatric population. Methods: Four anthropomorphic phantoms, representing a range of pediatric body habitus, were scanned with MOSFET dosimeters placed at 23 organ locations to determine absolute organ dosimetry. Phantom organ dosimetry was divided by phantom SSDE to determine correlation between organ dose and SSDE. Correlation factors were then multiplied by patient SSDE to estimate patient organ dose. Patient demographics consisted of 352 chest and 241 abdominopelvic CT examinations, 22 ± 15 kg (range 5−55 kg) mean weight, and 6 ± 5 years (range 4 mon to 23 years) mean age. Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm. 23 organ correlation factors were determined in the chest and abdominopelvic region across nine pediatric weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7−1.4) and abdominopelvic (average 0.9; range 0.7−1.3) was near unity. For organs that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1−0.4) for both the chest and abdominopelvic regions, respectively. Pediatric organ dosimetry was compared to published values and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusion: Average correlation of SSDE and organ dosimetry was found to be better than ± 10% for fully covered organs within the scan volume. This study provides a list of organ dose correlation factors for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.

  10. Simple shielding reduces dose to the contralateral breast during prone breast cancer radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, Uma, E-mail: uma.goyal@gmail.com; Locke, Angela; Smith-Raymond, Lexie; Georgiev, Georgi N.

    2016-07-01

    shielded dose means were 12.68 and 1.54 cGy, respectively. When comparing medial and lateral portions of the contralateral bolus-based doses without and with Pb, the shield significantly reduced dose to both sides of the contralateral breast (medial p = 2.64 × 10{sup −14}, lateral p = 4.91 × 10{sup −6}). The prone 0.2-cm Pb shield significantly reduced scatter dose to the contralateral breast on the order of 2 to 3 times. Reductions may be clinically relevant for women younger than 45 years by decreasing the risk of contralateral radiation-induced breast cancer in patients receiving radiation therapy for breast cancer. This shield is simple as it would be a part of the prone breast board during treatments, but future studies are warranted for safety and efficacy clinically.

  11. Dose rate mapping and quantitative analysis of radioactive deposition with simple monitoring instruments in Finland after the Chernobyl accident.

    Energy Technology Data Exchange (ETDEWEB)

    Koivukoski, J. [Ministry of the Interior, Rescue Dept., Helsinki (Finland); Paatero, J. [Finnish Meteorological Inst., Helsinki (Finland)], E-mail: janne.koivukoski@intermin.fi

    2013-03-01

    This article reviews the Finnish dose-rate mapping equipment and the system to process the obtained results, which were used immediately after the 1986 Chernobyl accident. We present the results of the external gamma-radiation monitoring carried out with simple civil-defence gamma monitoring instruments and compare them with the subsequent deposition mapping performed with research-grade instruments. The analysis shows that the quality of radiation mapping is good enough for decision makers to direct protective measures to the right areas. This review also demonstrates that a simple stationary external gamma radiation monitoring network can be effectively used for early warning in radiation emergency situations. (orig.)

  12. Proton dose distribution measurements using a MOSFET detector with a simple dose‐weighted correction method for LET effects

    Science.gov (United States)

    Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-01-01

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth‐dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high‐bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L‐shaped bolus. The dose reproducibility, angular dependence and depth‐dose response were evaluated using a 190 MeV proton beam. Depth‐output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose‐weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L‐shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors. PACS number: 87.56.‐v

  13. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Jainil P., E-mail: jainil.shah@duke.edu [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); Mann, Steve D. [Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); McKinley, Randolph L. [ZumaTek, Inc., Research Triangle Park, North Carolina 27709 (United States); Tornai, Martin P. [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2015-08-15

    central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

  14. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    International Nuclear Information System (INIS)

    Shah, Jainil P.; Mann, Steve D.; McKinley, Randolph L.; Tornai, Martin P.

    2015-01-01

    central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements

  15. The Economics of Vaccinating or Dosing Cattle against Disease: A Simple Linear Cost-Benefit Model with Modifications

    OpenAIRE

    Tisdell, Clem; Ramsay, Gavin

    1995-01-01

    Outlines a simple linear cost-benefit model for determining whether it is economic at the farm-level to vaccinate or dose a batch of livestock against a disease. This model assumes that total benefits and costs are proportional to the number of animals vaccinated. This model is then modified to allow for the possibility of programmes of vaccination or disease prevention involving start-up costs which increase, but at a decreasing rate with batch size or with the size of the herd to be vaccina...

  16. Vacinação contra a hepatite B entre cirurgiões dentistas

    Directory of Open Access Journals (Sweden)

    Martins Andréa Maria Eleutério de Barros Lima

    2003-01-01

    Full Text Available OBJETIVO: Inquéritos sorológicos realizados em diversos países mostraram uma maior prevalência da infecção pelo vírus da hepatite B (VHB em dentistas, especialmente entre os cirurgiões, do que na população geral. O estudo realizado objetivou determinar a prevalência e os fatores associados à vacinação contra hepatite B (HB entre os dentistas e investigar as principais razões alegadas para a não vacinação e vacinação incompleta. MÉTODOS: Foi conduzido um inquérito entre 299 cirurgiões dentistas residentes em Montes Claros, MG, por meio de questionário auto-aplicável. Foi determinada a prevalência de vacinação segundo o número de doses e os fatores associados à não vacinação e à vacinação incompleta através de regressão logística multinomial. RESULTADOS: Dos 299 questionários distribuídos, 296 (99% foram respondidos. Destes, 74,9% tomaram três doses; 14%, duas doses; 2%, uma dose e 10% não foram vacinados. A vacinação completa foi maior entre os que relataram fazer exclusivamente cirurgia e/ou periodontia (89%. A principal razão alegada para a não vacinação ou vacinação incompleta foi a necessitade de maiores informações. A não vacinação foi mais freqüente entre aqueles com mais de 40 anos (OR=8,62; IC 95%: 1,88-39,41 e os que não se reciclaram nos dois anos prévios ao inquérito (OR=2,72; IC 95%: 1,02-7,22. A vacinação incompleta foi maior entre os que não usam luva no trabalho (OR=2,32; IC 95%: 1,08-4,97. CONCLUSÃO: A falta de informação, possivelmente relacionada a menor reciclagem profissional, parece ser um dos principais fatores limitantes da vacinação.

  17. Estudo da circulação hepatomesentérica pela angiografia por ressonância magnética com gadolínio: comparação entre doses simples e dupla no estudo de pacientes esquistossomóticos Gadolinium-enhanced magnetic resonance angiography for hepatomesenteric vascular evaluation: single and double doses comparison in schistosomiasis patients

    Directory of Open Access Journals (Sweden)

    Rogério Pedreschi Caldana

    2006-08-01

    Full Text Available OBJETIVO: Determinar a freqüência de visualização dos segmentos da circulação hepatomesentérica pela angiografia por ressonância magnética (angio-RM com contraste e comparar o valor do método, utilizando-se duas diferentes dosagens de gadolínio (doses simples e dupla. MATERIAIS E MÉTODOS: Estudo prospectivo de 36 pacientes esquistossomóticos submetidos a angio-RM. Os exames foram realizados em equipamento de RM de 1,5 T, usando-se bobina de corpo e bomba injetora para a administração endovenosa do contraste. Foram utilizadas, de maneira randomizada, dose dupla do contraste paramagnético (0,2 mmol/kg de Gd-DTPA em 21 pacientes e dose simples (0,1 mmol/kg em outros 15 pacientes. Os exames foram interpretados por dois observadores em consenso, que classificaram o grau de visualização de 25 segmentos vasculares estabelecidos para análise, sem conhecimento da dose de gadolínio utilizada. RESULTADOS: Os segmentos vasculares proximais e de maior calibre foram as estruturas com melhor grau de visualização na maioria da amostra em estudo. O tronco celíaco, a artéria hepática comum, a artéria esplênica, a croça e terço médio da artéria mesentérica superior, a veia porta, a veia esplênica e a veia mesentérica superior apresentaram grau 2 de visualização em mais de 70% da amostra. Quanto à comparação das diferentes dosagens, não houve diferença significante (p OBJECTIVE: To evaluate the visibility of hepatomesenteric vascular segments by 3D gadolinium-enhanced magnetic resonance (MR angiography and to compare the method effectiveness between two different gadolinium doses (single and double doses. MATERIALS AND METHODS: A prospective study was performed with 36 schistosomiasis patients who were submitted to 3D contrast-enhanced MR angiography. Scans were performed in a high-field equipment (1.5 T, with body coil and power injector for intravenous contrast administration. Contrast double doses (Gd-DTPA 0.2 mmol/kg and

  18. Design, implementation and verification of software code for radiation dose assessment based on simple generic environmental model

    International Nuclear Information System (INIS)

    I Putu Susila; Arif Yuniarto

    2017-01-01

    Radiation dose assessment to determine the potential of radiological impacts of various installations within nuclear facility complex is necessary to ensure environmental and public safety. A simple generic model-based method for calculating radiation doses caused by the release of radioactive substances into the environment has been published by the International Atomic Energy Agency (IAEA) as the Safety Report Series No. 19 (SRS-19). In order to assist the application of the assessment method and a basis for the development of more complex assessment methods, an open-source based software code has been designed and implemented. The software comes with maps and is very easy to be used because assessment scenarios can be done through diagrams. Software verification was performed by comparing its result to SRS-19 and CROM software calculation results. Dose estimated by SRS-19 are higher compared to the result of developed software. However, these are still acceptable since dose estimation in SRS-19 is based on conservative approach. On the other hand, compared to CROM software, the same results for three scenarios and a non-significant difference of 2.25 % in another scenario were obtained. These results indicate the correctness of our implementation and implies that the developed software is ready for use in real scenario. In the future, the addition of various features and development of new model need to be done to improve the capability of software that has been developed. (author)

  19. Effect of a simple dose-escalation schedule on tramadol tolerability : assessment in the clinical setting.

    Science.gov (United States)

    Tagarro, I; Herrera, J; Barutell, C; Díez, M C; Marín, M; Samper, D; Busquet, C; Rodríguez, M J

    2005-01-01

    To assess the effect of a very simple dose-escalation schedule on tramadol tolerability in clinical practice. This schedule consists of starting treatment with sustained-release tramadol 50mg twice daily, and escalating the dose around 7 days later to 100mg twice daily. Data from 1925 outpatients with non-malignant chronic pain were collected in this multicentre, prospective, comparative, non-randomised, open, observational study. A total of 1071 patients (55.6%) were included in the dose-escalation group (50mg group) and 854 patients (44.4%) in the control group (sustained-release tramadol 100mg twice daily; 100mg group). The proportion of patients who interrupted tramadol treatment due to the occurrence of adverse reactions was significantly lower in the 50mg group (5.6%) than in the 100mg group (12.6%) [p = 0.001]. In line with this, the proportion of patients who experienced at least one adverse reaction was significantly lower in the 50mg group (18.4%) than in the 100mg group (30.4%) [p = 0.001] and, interestingly, the two most frequently reported adverse reactions, nausea and dizziness, were found with a significantly lower frequency in the 50mg group (p < 0.001). Multivariate analysis showed that the risk of safety-related treatment cessations was 2.3 times higher in the 100mg group than in the 50mg group, and 2.2 times higher in females than in males. The two treatments were equally effective in reducing pain intensity (p = 0.121), measured as a reduction in pain score obtained by means of a visual analogue scale. The instauration of tramadol treatment, starting with sustained-release 50mg capsules twice daily and escalating the dose some days later to 100mg twice daily, was shown to be an effective and easy way to improve tramadol tolerability in clinical practice, whilst maintaining its analgesic efficacy.

  20. Dose indices: everybody wants a number

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2014-01-01

    This paper discusses the merits and weaknesses of the standard terms that have been developed to quantify CT dose: CT dose indices (CTDI), dose length product (DLP) and effective dose. The difference between the measured CTDI vol and the CTDI vol displayed on the CT scanner illustrates a clinical dilemma. Displayed CTDI vol represents the radiation dose delivered to a plastic phantom, which is significantly different from the dose delivered to the patient, depending on the size of the patient. Although effective dose is simple to calculate for an individual patient, it was never intended for this purpose. The need for a simple, appropriate method to estimate pediatric patient doses led to the development of the size-specific dose estimate (SSDE), the newest CT dose index. Here I compare SSDE and its merits to the use of effective dose to estimate patient dose. The discussion concludes with a few sample calculations and basic clinical applications of SSDE to better quantify pediatric patient dose from CT scans. (orig.)

  1. Fast in vivo volume dose reconstruction via reference dose perturbation

    International Nuclear Information System (INIS)

    Lu, Weiguo; Chen, Mingli; Mo, Xiaohu; Parnell, Donald; Olivera, Gustavo; Galmarini, Daniel

    2014-01-01

    Purpose: Accurate on-line reconstruction of in-vivo volume dose that accounts for both machine and patient discrepancy is not clinically available. We present a simple reference-dose-perturbation algorithm that reconstructs in-vivo volume dose fast and accurately. Methods: We modelled the volume dose as a function of the fluence map and density image. Machine (output variation, jaw/leaf position errors, etc.) and patient (setup error, weight loss, etc.) discrepancies between the plan and delivery were modelled as perturbation of the fluence map and density image, respectively. Delivered dose is modelled as perturbation of the reference dose due to change of the fluence map and density image. We used both simulated and clinical data to validate the algorithm. The planned dose was used as the reference. The reconstruction was perturbed from the reference and accounted for output-variations and the registered daily image. The reconstruction was compared with the ground truth via isodose lines and the Gamma Index. Results: For various plans and geometries, the volume doses were reconstructed in few seconds. The reconstruction generally matched well with the ground truth. For the 3%/3mm criteria, the Gamma pass rates were 98% for simulations and 95% for clinical data. The differences mainly appeared on the surface of the phantom/patient. Conclusions: A novel reference-dose-perturbation dose reconstruction model is presented. The model accounts for machine and patient discrepancy from planning. The algorithm is simple, fast, yet accurate, which makes online in-vivo 3D dose reconstruction clinically feasible.

  2. On dose distribution comparison

    International Nuclear Information System (INIS)

    Jiang, Steve B; Sharp, Greg C; Neicu, Toni; Berbeco, Ross I; Flampouri, Stella; Bortfeld, Thomas

    2006-01-01

    In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spatial domains in order to be clinically relevant. Each of the existing comparison methods has its own strengths and weaknesses and there is room for improvement. In this work, we developed a general framework for comparing dose distributions. Using a new concept called maximum allowed dose difference (MADD), the comparison in both dose and spatial domains can be performed entirely in the dose domain. Formulae for calculating MADD values for various comparison methods, such as composite analysis and gamma index, have been derived. For convenience in clinical practice, a new measure called normalized dose difference (NDD) has also been proposed, which is the dose difference at a point scaled by the ratio of MADD to the predetermined dose acceptance tolerance. Unlike the simple dose difference test, NDD works in both low and high dose gradient regions because it considers both dose and spatial acceptance tolerances through MADD. The new method has been applied to a test case and a clinical example. It was found that the new method combines the merits of the existing methods (accurate, simple, clinically intuitive and insensitive to dose grid size) and can easily be implemented into any dose/intensity comparison tool

  3. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  4. The Relationship between Blood Injury and Absorbed Dose in Criticality Accidents; Relations entre la Deterioration du Sang et la Dose Absorbee lors d'Accidents Dus a la Formation d'un Etat Critique; Svyaz' mezhdu velichinoj pogloshchennoj dozy pri avariyakh na reaktorakh, dostigshikh kritichnosti, i narusheniem sostava krovi; Relacion entre las Hemolesiones y la Dosis Absorbida en los Accidentes de Criticidad

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, J. A. [Health Physics and Medical Division, Atomic Energy Research Establishment, Harwell (United Kingdom)

    1964-03-15

    The neutron and gamma doses to individuals exposed in criticality accidents have been recalculated to yield the surface-absorbed dose to the trunk of the body. The relationship is examined between this dose estimate and blood-count profile scores that are based on the scoring system of N. Wald and G. E. Thoma for deviations from the normal of the lymphocyte, neutrophil and platelet-peripheral blood counts. It is shown that a quantity based on the surface-absorbed gamma dose and the Na{sup 24} activity in the blood shows a better correlation with the blood-count profile score and is a better prognostic guide for the degree of radiation injury than any of the conventional dose estimates. The R. B. E's of the heavy-particle recoil doses deduced from these observations are consistent in general with values obtained from experiments on dogs. (author) [French] L'auteur a fait un nouveau calcul des doses de neutrons et de rayons gamma delivrees aux personnes exposees lors d'accidents due a la formation d'un etat critique, pour obtenir la dose en surface absorbee par le tronc. Il a etudie la relation entre cette estimation de la dose et la 'courbe resultante de numeration globulaire' de N. Wald et G. E. Thoma du point de vue des anomalies en lymphocytes, polynucleaires neutrophiles et plaquettes. Il montre qu'une quantite fondee sur la dose absorbee en surface de rayons gamma et l'activite de {sup 24}Na dans le sang accuse une meilleure correlation avec la courbe resultante de numeration globulaire et permet de mieux prevoir le degre de radiolesion que toute autre estimation classique de la dose. Les EBR des doses dues aux particules lourdes de recul, deduites de ces observations, concordent dans l'ensemble avec les valeurs obtenues au cours d'experiences sur des chiens. (author) [Spanish] El autor reviso sus calculos sobre las dosis de neutrones y rayos gamma en los sujetos expuestos a consecuencia de accidentes de criticidad, a fin de determinar las dosis superficiales

  5. Sutura simples e âncora em quadris de coelhos Simple suture and anchor in rabbit hips

    Directory of Open Access Journals (Sweden)

    Fernando Cal Garcia Filho

    2012-01-01

    Full Text Available OBJETIVO: Por meio de ensaios biomecânicos, comparar as capsulorrafias com sutura simples e com âncoras, em quadris de coelhos. MÉTODO: Foram utilizados 13 coelhos, 26 quadris, todos machos da raça Nova Zelândia albinos (Oryctolaguscuniculus. Inicialmente, realizamos um projeto piloto em três coelhos (seis quadris. Este experimento constou de 10 coelhos, divididos em 2 grupos: o Grupo 1 submetido à capsulorrafia (quadris direito e esquerdo com sutura simples utilizando fio absorvível de ácido poliglicólico e o Grupo 2 submetido a capsulorrafia (quadris direito e esquerdo com âncora de titânio. Após o período de quatro semanas de operados, todos animais foram submetidos à eutanásia e seus quadris congelados. Após um descongelamento prévio das peças, no mesmo dia das análises biomecânicas, foram avaliados os parâmetros de rigidez, força máxima, deformidade máxima e energia. RESULTADOS: Não houve diferença estatisticamente significante em relação à força no limite de proporcionalidade, rigidez e força máxima entre os grupos com sutura simples e com âncora. CONCLUSÃO: Por meio dos ensaios biomecânicos, tendo como parâmetro a rigidez, a força máxima, a deformidade máxima e a energia, ficou demonstrado que as capsulorrafias em quadris de coelhos com sutura simples e com âncora são semelhantes entre si. Nível de Evidência II, Estudo Prospectivo Comparativo.OBJECTIVE: Using biomechanical studies, this research aims to compare hip capsulorrhaphy in rabbits, carried out with two different techniques: capsulorrhaphy with simple sutures and with anchors. METHOD: Thirteen New Zealand Albino (Oryctolaguscuniculus male rabbits, twenty-six hip joints, were used. First, a pilot project was performed with three rabbits (six hip joints. This experiment consisted of ten rabbits divided into two groups: group 1 underwent capsulorrhaphy on both right and left hips with simple suture using polyglycolic acid absorbable thread

  6. Effect of exposure dose reduction using a compensating filter

    International Nuclear Information System (INIS)

    Katsuda, Toshizo; Nakajima, Tadashi; Kuwano, Tadao; Ueda, Kouki; Sasaki, Yasuhiro; Yoshida, Jiro

    1993-01-01

    It is empirically said that the application of the compensating filter leads to a decrease in the exposure dose of the filter-inserted area and an increase in that of the otherwise area. Using the area-dosimeter, comparison was made of exposure doses by the application of the above filter and the otherwise filter in head simple X-P, abdominal angiography and lower extremity X-P. Using the filter for head simple X-P and Mix-Dp phantom, measurement was made of the absorbed dose at the 5 cm-depth to compare the rate of decrease in absorbed dose between the above both areas. Head simple X-P gained a decrease in area dose of 29%. The absorbed dose at the 5 cm-depth in the phantom experiment showed a decrease of over 26% at the filter-inserted area, but little increase at the otherwise area. The above results indicated the interposition of the filter between the X-ray tube and the object to lead to decreases not only in the area dose but also in the patient's exposure dose. (author)

  7. Entre/Plantas

    OpenAIRE

    Montoro Coso, Ricardo; Sonntag, Franca Alexandra

    2014-01-01

    La palabra Inter-és proviene etimológicamente de las palabras latinas inter y esse; y significa “lo que está-entre dos o más personas, o sea lo que las une pero también las separa”. Los prefijos inter- y entre-, en la mayor parte de los casos, describen estados o acciones ambiguas de los términos que preceden. De esta operación aditiva surgen maclas de vocablos; el inter-sticio como la “hendidura o espacio que media entre dos cuerpos o entre dos partes de un mismo cuerpo”; y así sucesivamente...

  8. Estudo comparativo das técnicas radiográficas e doses entre o Brasil e a Austrália Comparison between radiological techniques and doses used in Brazil and in Australia

    Directory of Open Access Journals (Sweden)

    Ana Cecília Pedrosa de Azevedo

    2005-09-01

    Full Text Available OBJETIVO: O objetivo deste trabalho é fazer um estudo comparativo das técnicas radiográficas entre o Brasil e a Austrália e avaliar as doses de radiação para os exames radiológicos mais comuns. MATERIAIS E MÉTODOS: A dose de entrada na pele (DEP e a dose efetiva (DE foram obtidas com o uso do programa DoseCal. Em ambos os países, o estudo foi realizado em hospitais de grande porte da rede pública. Quatro tipos de exames foram avaliados: tórax, abdome, pelve e coluna torácica em três projeções (ântero-posterior, póstero-anterior e lateral. Na Austrália, todos os equipamentos são digitais e operam no sistema PACS. No Brasil, os aparelhos são convencionais. RESULTADOS: Os valores médios da DEP e da DE são consideravelmente mais altos no Brasil, exceto para os exames de tórax, cujos resultados indicaram índices menores. As maiores diferenças encontradas foram para os exames de pelve (26 vezes maior no Brasil e de coluna torácica (43 vezes maior no Brasil. O mesmo acontece para os valores da DE. CONCLUSÃO: Nos hospitais australianos, os programas de controle e garantia de qualidade (PCGQ fazem parte da rotina nos serviços de radiologia. Contam com equipamentos digitais de última geração e os serviços possuem uma equipe de física médica atuante. Esse conjunto de iniciativas resulta na produção de imagens radiográficas de alta qualidade, com baixas doses e índices de rejeição próximos a zero. Tais resultados apontam para a necessidade de se estimular a implantação de PCGQ em toda a rede hospitalar brasileira. No entanto, analisando os resultados de DEP nos exames de tórax, concluímos que doses baixas também são possíveis no Brasil se forem empregadas técnicas radiográficas adequadas.OBJECTIVE: To compare radiological techniques used in Brazil and in Australia, and to evaluate radiation doses of the most common x-ray procedures. MATERIALS AND METHODS: The entrance skin dose (ESD and the effective dose

  9. A simple and fast physics-based analytical method to calculate therapeutic and stray doses from external beam, megavoltage x-ray therapy.

    Science.gov (United States)

    Jagetic, Lydia J; Newhauser, Wayne D

    2015-06-21

    State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 min. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models.

  10. High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference.

    Science.gov (United States)

    Piketty, Marie-Liesse; Prie, Dominique; Sedel, Frederic; Bernard, Delphine; Hercend, Claude; Chanson, Philippe; Souberbielle, Jean-Claude

    2017-05-01

    High-dose biotin therapy is beneficial in progressive multiple sclerosis (MS) and is expected to be adopted by a large number of patients. Biotin therapy leads to analytical interference in many immunoassays that utilize streptavidin-biotin capture techniques, yielding skewed results that can mimic various endocrine disorders. We aimed at exploring this interference, to be able to remove biotin and avoid misleading results. We measured free triiodothyronine (fT3), free thyroxine (fT4), thyroid-stimulating hormone (TSH), parathyroid homrone (PTH), 25-hydroxyvitamin D (25OHD), follicle-stimulating hormone (FSH), luteinizing hormone (LH), prolactin, C-peptide, cortisol (Roche Diagnostics assays), biotin and its main metabolites (liquid chromatography tandem mass spectrometry) in 23 plasmas from MS patients and healthy volunteers receiving high-dose biotin, and in 39 biotin-unsupplemented patients, before and after a simple procedure (designated N5) designed to remove biotin by means of streptavidin-coated microparticles. We also assayed fT4, TSH and PTH in the 23 high-biotin plasmas using assays not employing streptavidin-biotin binding. The biotin concentration ranged from 31.7 to 1160 µg/L in the 23 high-biotin plasmas samples. After the N5 protocol, the biotin concentration was below the detection limit in all but two samples (8.3 and 27.6 μg/L). Most hormones results were abnormal, but normalized after N5. All results with the alternative methods were normal except two slight PTH elevations. In the 39 biotin-unsupplemented patients, the N5 protocol did not affect the results for any of the hormones, apart from an 8.4% decrease in PTH. We confirm that most streptavidin-biotin hormone immunoassays are affected by high biotin concentrations, leading to a risk of misdiagnosis. Our simple neutralization method efficiently suppresses biotin interference.

  11. Correlação entre métodos de avaliação da qualidade da dose de diálise La correlación entre los métodos de evaluación de la calidad de la dosis de diálisis Comparison between two methods for evaluation of the dialysis dose quality

    Directory of Open Access Journals (Sweden)

    Kelly Cristina Inoue

    2009-01-01

    Full Text Available OBJETIVO: Verificar a correlação entre o Kt/V calculado e o Kt/V-OCM. MÉTODOS: Estudo transversal, retrospectivo, com 14 pacientes submetidos a 106 hemodiálises com a máquina Fresenius 4008S, realizado numa Unidade de Terapia Intensiva para adultos, de um Hospital de Ensino do noroeste do Paraná, no período de novembro/2007 a abril/2008. RESULTADOS: Através do teste de Shapiro-Wilk, (p>0,05, foi constatado que não houve distribuição normal entre o "Kt/V calculado" e o "Kt/V da máquina". CONCLUSÃO: Pelo teste de Wilcoxon concluiu-se que houve diferença significativa (pOBJETIVO: Verificar la correlación entre el Kt/V calculado y el Kt/V-OCM. MÉTODOS: Estudio transversal, retrospectivo, con 14 pacientes sometidos a 106 hemodiálisis con la máquina Fresenius 4008S, realizado en una Unidad de Cuidados Intensivos para adultos, de un Hospital Docente del noroeste del Paraná, en el período de noviembre/2007 a abril/2008. RESULTADOS: A través del test de Shapiro-Wilk, (p>0,05, se constató que no hubo distribución normal entre el "Kt/V calculado" y el "Kt/V de la máquina". Por el test de Wilcoxon hubo diferencia significativa (pPURPOSE: To compare calculated Kt/V and Kt/V-OCM methods of dialysis dose. METHODS: This was a cross-sectional retrospective study with 14 patients who underwent 106 hemodialysis using Fresenius 4008S dialysis machine in the critical care unit of the "Noroeste Parana Teaching Hospital" from November 2007 to April 2008. RESULTS: Shapiro-Wilk test indicated that there was no normal distribution between the calculated Kt/V and the machine Kt/V (p>0.05. Wilcoxon test showed a statistically significant difference between the two measurements (p <.0001. CONCLUSION: There is a need for further studies that consider all factors involved with the online calculation of the urea depuration for the utilization of the Kt/V-OCM.

  12. A patient dose survey for femoral arteriogram diagnostic radiographic examinations using a dose-area product meter

    International Nuclear Information System (INIS)

    Thwaites, J.H.; Rafferty, M.W.; Gray, N.; Black, J.; Stock, B.

    1996-01-01

    A patient dose survey was carried out for femoral arteriogram procedures at the Sir Charles Gairdner Hospital. The procedure involves fluoroscopy to the pelvic region to locate a guide wire and catheter, followed by a series of radiographs extending from the pelvic area to the feet to form a collage image of the entire arterial system. Radiographs are taken whilst a bolus of contrast media is injected into the arterial system. A dose-area product meter was used to determine the dose-area product delivered to patients. Radiographic and patient details were logged with dose-area product for each part of each procedure. Mean energy imparted, mean effective dose and effective dose equivalent are calculated for the examinations. Calculated effective doses are shown to produce results consistent with those of other authors. We present a method for dealing with a complex radiographic procedure including multiple radiographs and fluoroscopy in an attempt to provide a simple way of calculating effective dose from which a general risk factor can be determined. The effective dose varies considerably from examination to examination due to the large range in the number of radiographs taken in any one procedure. A useful index can be obtained by logging the number of radiographs in each region, and fluoroscopy time, from which the effective dose may be easily calculated. These measurements extend a continuing survey of doses for common diagnostic radiographic examinations which previously included the simple examinations: lumbar spine, abdoment and pelvis. (author)

  13. A simple method for estimating the effective dose in dental CT. Conversion factors and calculation for a clinical low-dose protocol

    International Nuclear Information System (INIS)

    Homolka, P.; Kudler, H.; Nowotny, R.; Gahleitner, A.; Wien Univ.

    2001-01-01

    An easily appliable method to estimate effective dose including in its definition the high radio-sensitivity of the salivary glands from dental computed tomography is presented. Effective doses were calculated for a markedly dose reduced dental CT protocol as well as for standard settings. Data are compared with effective doses from the literature obtained with other modalities frequently used in dental care. Methods: Conversion factors based on the weighted Computed Tomography Dose Index were derived from published data to calculate effective dose values for various CT exposure settings. Results: Conversion factors determined can be used for clinically used kVp settings and prefiltrations. With reduced tube current an effective dose for a CT examination of the maxilla of 22 μSv can be achieved, which compares to values typically obtained with panoramic radiography (26 μSv). A CT scan of the mandible, respectively, gives 123 μSv comparable to a full mouth survey with intraoral films (150 μSv). Conclusion: For standard CT scan protocols of the mandible, effective doses exceed 600 μSv. Hence, low dose protocols for dental CT should be considered whenever feasable, especially for paediatric patients. If hard tissue diagnoses is performed, the potential of dose reduction is significant despite the higher image noise levels as readability is still adequate. (orig.) [de

  14. Angular dependence of shallow dose

    International Nuclear Information System (INIS)

    Alvarez, J.L.

    1986-01-01

    The theoretical response of a detector is discussed and compared to measurements of shallow dose with tissue and phantom response detectors. A definite energy dependent angular response of dose and measurement was observed which could not be explained by simple trigonometric arguments. The response is back scatter dependent and must be considered in detector design and dose measurements. It is not possible for standard detectors to follow this response

  15. Mixed field dose equivalent measuring instruments

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; McDonald, J.C.; Endres, G.W.R.; Quam, W.

    1985-01-01

    In the past, separate instruments have been used to monitor dose equivalent from neutrons and gamma rays. It has been demonstrated that it is now possible to measure simultaneously neutron and gamma dose with a single instrument, the tissue equivalent proportional counter (TEPC). With appropriate algorithms dose equivalent can also be determined from the TEPC. A simple ''pocket rem meter'' for measuring neutron dose equivalent has already been developed. Improved algorithms for determining dose equivalent for mixed fields are presented. (author)

  16. Repair and dose-response at low doses

    International Nuclear Information System (INIS)

    Totter, J.R.; Weinberg, A.M.

    1977-04-01

    The DNA of each individual is subject to formation of some 2-4 x 10 14 ion pairs during the first 30 years of life from background radiation. If a single hit is sufficient to cause cancer, as is implicit in the linear, no-threshold theories, it is unclear why all individuals do not succumb to cancer, unless repair mechanisms operate to remove the damage. We describe a simple model in which the exposed population displays a distribution of repair thresholds. The dose-response at low dose is shown to depend on the shape of the threshold distribution at low thresholds. If the probability of zero threshold is zero, the response at low dose is quadratic. The model is used to resolve a longstanding discrepancy between observed incidence of leukemia at Nagasaki and the predictions of the usual linear hypothesis

  17. Local dose assessment for a contaminated wound

    International Nuclear Information System (INIS)

    Piechowski, J.; Chaptinel, Y.

    2004-01-01

    Contaminated wounds present a great variability concerning the type of lesion. Assessment of the local dose is one amongst other factors for a decision as to the surgical operation. A simple model has been used to calculate the doses in a representative volume, that of a phalanx for instance. The dose rates are given for current radionuclides. The method of calculation is enough simple in order to allow the practitioners to use it in situations involving other radionuclides. Committed dose depends on the biological half-life which can be estimated from the local measurements. Some examples of calculation of committed dose are given considering half-lives characteristic of the compound. Transposition of the dose to the local risk is easy for the non-stochastic risk. Conversely, this is not the case for the risk of chronic inflammation or cancer. The latter question could only be solved by a feedback based on the analysis of real till now observed cases, nevertheless taking into account the fact that the available data are generally not so easy to make use for establishing an unquestionable dose - effect relation. A critical issue remains open as to the use of these doses for their comparison to the regulatory limits and for the subsequent decisions in case of exceeding the limits. The actual impact of an irradiation, especially by alpha particles, is not linked to the calculated dose in a simple and direct way. This question needs further consideration and perhaps a practical guide concerning this topic would be useful. The anatomical (surgical side effects), psychological and professional consequences should have a large weight relatively to the doses, obviously except for the cases, involving actually large contamination. (authors)

  18. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  19. Application of a simple analytical model to estimate effectiveness of radiation shielding for neutrons

    International Nuclear Information System (INIS)

    Frankle, S.C.; Fitzgerald, D.H.; Hutson, R.L.; Macek, R.J.; Wilkinson, C.A.

    1993-01-01

    Neutron dose equivalent rates have been measured for 800-MeV proton beam spills at the Los Alamos Meson Physics Facility. Neutron detectors were used to measure the neutron dose levels at a number of locations for each beam-spill test, and neutron energy spectra were measured for several beam-spill tests. Estimates of expected levels for various detector locations were made using a simple analytical model developed for 800-MeV proton beam spills. A comparison of measurements and model estimates indicates that the model is reasonably accurate in estimating the neutron dose equivalent rate for simple shielding geometries. The model fails for more complicated shielding geometries, where indirect contributions to the dose equivalent rate can dominate

  20. A patient dose survey or femoral arteriogram diagnostic radiographic examinations using a dose-area product meter

    International Nuclear Information System (INIS)

    Thwaites, J.H.; Rafferty, M.W.; Gray, N.; Black, J.; Stock, B.

    1996-01-01

    We present a method for dealing with a complex radiographic procedure (which involves multiple radiographs and fluoroscopy) in an attempt to provide a simple way of calculating effective dose from which a general risk factor can be determined. A useful index of harm can be obtained by recording the number of radiographs in each region, and the fluoroscopy time, from which the effective dose may be easily calculated. A patient dose survey was carried out using a PTW diamentor for femoral arteriogram procedures in a large teaching hospital. The procedure involves fluoroscopy to the pelvic region to locate a guide wire and catheter, followed by a series of radiographs extending from the pelvic area to the feet to form a collage image of the entire arterial system. Radiographs are taken whilst a bolus of contrast media is injected into the arterial system. The measurements extend a continuing survey of doses for common diagnostic radiographic examinations which have previously included the simple examinations of lumbar spine, abdomen and pelvis. (Author)

  1. Non-linear least squares curve fitting of a simple theoretical model to radioimmunoassay dose-response data using a mini-computer

    International Nuclear Information System (INIS)

    Wilkins, T.A.; Chadney, D.C.; Bryant, J.; Palmstroem, S.H.; Winder, R.L.

    1977-01-01

    Using the simple univalent antigen univalent-antibody equilibrium model the dose-response curve of a radioimmunoassay (RIA) may be expressed as a function of Y, X and the four physical parameters of the idealised system. A compact but powerful mini-computer program has been written in BASIC for rapid iterative non-linear least squares curve fitting and dose interpolation with this function. In its simplest form the program can be operated in an 8K byte mini-computer. The program has been extensively tested with data from 10 different assay systems (RIA and CPBA) for measurement of drugs and hormones ranging in molecular size from thyroxine to insulin. For each assay system the results have been analysed in terms of (a) curve fitting biases and (b) direct comparison with manual fitting. In all cases the quality of fitting was remarkably good in spite of the fact that the chemistry of each system departed significantly from one or more of the assumptions implicit in the model used. A mathematical analysis of departures from the model's principal assumption has provided an explanation for this somewhat unexpected observation. The essential features of this analysis are presented in this paper together with the statistical analyses of the performance of the program. From these and the results obtained to date in the routine quality control of these 10 assays, it is concluded that the method of curve fitting and dose interpolation presented in this paper is likely to be of general applicability. (orig.) [de

  2. Radon-222 related influence on ambient gamma dose.

    Science.gov (United States)

    Melintescu, A; Chambers, S D; Crawford, J; Williams, A G; Zorila, B; Galeriu, D

    2018-04-03

    Ambient gamma dose, radon, and rainfall have been monitored in southern Bucharest, Romania, from 2010 to 2016. The seasonal cycle of background ambient gamma dose peaked between July and October (100-105 nSv h -1 ), with minimum values in February (75-80 nSv h -1 ), the time of maximum snow cover. Based on 10 m a.g.l. radon concentrations, the ambient gamma dose increased by around 1 nSv h -1 for every 5 Bq m -3 increase in radon. Radon variability attributable to diurnal changes in atmospheric mixing contributed less than 15 nSv h -1 to the overall variability in ambient gamma dose, a factor of 4 more than synoptic timescale changes in air mass fetch. By contrast, precipitation-related enhancements of the ambient gamma dose were 15-80 nSv h -1 . To facilitate routine analysis, and account in part for occasional equipment failure, an automated method for identifying precipitation spikes in the ambient gamma dose was developed. Lastly, a simple model for predicting rainfall-related enhancement of the ambient gamma dose is tested against rainfall observations from events of contrasting duration and intensity. Results are also compared with those from previously published models of simple and complex formulation. Generally, the model performed very well. When simulations underestimated observations the absolute difference was typically less than the natural variability in ambient gamma dose arising from atmospheric mixing influences. Consequently, combined use of the automated event detection method and the simple model of this study could enable the ambient gamma dose "attention limit" (which indicates a potential radiological emergency) to be reduced from 200 to 400% above background to 25-50%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Dose gradient curve: A new tool for evaluating dose gradient.

    Science.gov (United States)

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  4. Gonad dose in cineurethrocystography

    International Nuclear Information System (INIS)

    Ardran, G.M.; Dixon-Brown, A.; Fursdon, P.S.

    1978-01-01

    The technical factors used for cineurethrocystography for the true lateral projection in females are given. The mid-line radiation dose has been measured with LiF TLD inserted into the vagina in 19 examinations. The average dose recorded was 148 mrad, the range being 50 to 306 mrad, the average number of cine frames exposed was 96. Data obtained using a Rando phantom indicated that the average ovary dose would be 30% greater than the mid-line dose since the near ovary receives a higher dose than the more distant one. The technique used for men is also given, the average gonad dose in six men being 123 mrad, range 56 to 243 mrad when simple lead foil gonad protection was used; the average number of cine frames was 107. The dose in one man without gonad protection was 1575 mrad for 112 cine frames. The results for both sexes compare favourably with those of others reported in the literature and with gonad doses recorded in typical IVP examinations. (author)

  5. The calculation of dose rates from rectangular sources

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1998-01-01

    A common problem in radiation protection is the calculation of dose rates from extended sources and irregular shapes. Dose rates are proportional to the solid angle subtended by the source at the point of measurement. Simple methods of calculating solid angles would assist in estimating dose rates from large area sources and therefore improve predictive dose estimates when planning work near such sources. The estimation of dose rates is of particular interest to producers of radioactive ores but other users of bulk radioactive materials may have similar interest. The use of spherical trigonometry can assist in determination of solid angles and a simple equation is derived here for the determination of the dose at any distance from a rectangular surface. The solid angle subtended by complex shapes can be determined by modelling the area as a patchwork of rectangular areas and summing the solid angles from each rectangle. The dose rates from bags of thorium bearing ores is of particular interest in Western Australia and measured dose rates from bags and containers of monazite are compared with theoretical estimates based on calculations of solid angle. The agreement is fair but more detailed measurements would be needed to confirm the agreement with theory. (author)

  6. Crescimento de mudas de gravioleira (Anonna muricata L. em substrato com superfosfato simples e vermicomposto Growing of soursup seedlings (Anonna muricata L. in substrate with simple superphosphate and earthworm

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Spaggiari Souza

    2003-12-01

    Full Text Available Objetivando avaliar o efeito de diferentes doses de superfosfato simples e vermicomposto no crescimento de mudas de gravioleira (Anonna muricata L., conduziu-se um experimento no Setor de Fruticultura da Universidade Federal de Lavras. Foram testadas, num Latossolo, quatro doses de superfosfato simples (0,0; 2,5; 5,0 e 10,0 kg e quatro doses de vermicomposto (0; 10; 20 e 40% m-3 de substrato. O delineamento experimental utilizado foi blocos ao acaso em esquema fatorial 4 x 4, com 4 repetições. Foram realizadas as seguintes determinações: altura de plantas (cm, diâmetro do caule (cm, número de folha/planta, área foliar (cm².planta-1, matéria seca de folha, do caule e de raiz (g.planta-1. Os resultados demonstraram que a aplicação de superfosfato simples na dose de 5 kg e 40% de vermicomposto por m³ de substrato proporcionaram a obtenção de mudas de gravioleira mais vigorosas.An experiment was conducted at the fruits sector of the Lavras Federal University -UFLA in order to evaluate the effect of different amounts of earthworm and simple superphosphate in the growing and nutrition of soursup seedlings (Anoma muricata L.. Four dosages of simple superphosphate (0,0; 2,5; 5,0 and 10,0 kg m-3 of substratum and four dosages of earthworm (0,0%; 10,0%; 20,0% and 40,0% of volume were tested at Latosol. The experimental design was randomized block in a two factors arrangement (4x4 with 4 replicates. The plants height (cm; stem diameter (cm; matter of the aerial part and roots (g per plant; number of leaves per plant and leaves area (cm².plant-1 were evaluated. The results showed that the use of simple superphosphate at 5kg m-3 with 40,0% of earthworm provided soursup seedlings with superior quality compared to the others.

  7. Estudo comparativo entre uma e duas doses efetivas (DE95 de rocurônio para a intubação traqueal Estudio comparativo entre una y de los dosis efectivas (DE95 de rocuronio para la intubación traqueal A comparative study between one and two effective doses (ED95 of rocuronium for tracheal intubation

    Directory of Open Access Journals (Sweden)

    Luciano Carlos Gomes de Miranda

    2008-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Os bloqueadores neuromusculares (BNM são fármacos utilizados para produzir relaxamento da musculatura esquelética e facilitar a intubação traqueal (IT. A literatura descreve como sendo necessárias duas doses efetivas (DE95 o ideal para a IT. O rocurônio é um BNM não-despolarizante do tipo esteróide, sintético e de duração intermediária. O objetivo desse estudo foi avaliar e comparar as condições de intubação traqueal (IT, utilizando uma e duas doses efetivas (DE95 do rocurônio, seguindo os critérios da Conferência de Consenso de Copenhague. MÉTODO: Foram avaliados 60 pacientes divididos aleatoriamente em dois grupos de 30, de ambos os sexos, idades entre 20 e 60 anos, estado físico ASA I e II, Mallampati 1 e 2, índice de massa corporal (IMC JUSTIFICATIVA Y OBJETIVOS: Los bloqueadores neuromusculares (BNM son fármacos utilizados para producir el relajamiento de la musculatura esquelética y facilitar la intubación traqueal (IT. La literatura describe que son necesarias de los dosis efectivas (DE95 lo ideal para la IT. El rocuronio es un BNM no despolarizador del tipo esteroide, sintético y de duración intermedia. El objetivo de este estudio fue evaluar y comparar las condiciones de intubación traqueal (IT, utilizando una y de los dosis efectivas (DE95 del rocuronio, secundando los criterios de la Conferencia de Consenso de Copenhague. MÉTODO: Se estudiaron 60 pacientes divididos aleatoriamente en 2 grupos de 30, de ambos sexos, edades entre 20 y 60 años, estado físico ASA I y II, Mallampati 1 y 2, índice de masa corporal (IMC BACKGROUND AND OBJECTIVES: Neuromuscular blockers (NMB are used to induce relaxation of skeletal muscles and facilitate tracheal intubation (TI. According to the literature, two effective doses (ED95 of NMB are ideal for TI. Rocuronium is a steroid-type, synthetic, non-depolarizing neuromuscular blocker of medium duration. The objective of this study was to evaluate

  8. Dose prescription complexity versus tumor control probability in biologically conformal radiotherapy

    International Nuclear Information System (INIS)

    South, C. P.; Evans, P. M.; Partridge, M.

    2009-01-01

    The technical feasibility and potential benefits of voxel-based nonuniform dose prescriptions for biologically heterogeneous tumors have been widely demonstrated. In some cases, an ''ideal'' dose prescription has been generated by individualizing the dose to every voxel within the target, but often this voxel-based prescription has been discretized into a small number of compartments. The number of dose levels utilized and the methods used for prescribing doses and assigning tumor voxels to different dose compartments have varied significantly. The authors present an investigation into the relationship between the complexity of the dose prescription and the tumor control probability (TCP) for a number of these methods. The linear quadratic model of cell killing was used in conjunction with a number of modeled tumors heterogeneous in clonogen density, oxygenation, or proliferation. Models based on simple mathematical functions, published biological data, and biological image data were investigated. Target voxels were assigned to dose compartments using (i) simple rules based on the initial biological distribution, (ii) iterative methods designed to maximize the achievable TCP, or (iii) methods based on an ideal dose prescription. The relative performance of the simple rules was found to depend on the form of heterogeneity of the tumor, while the iterative and ideal dose methods performed comparably for all models investigated. In all cases the maximum achievable TCP was approached within the first few (typically two to five) compartments. Results suggest that irrespective of the pattern of heterogeneity, the optimal dose prescription can be well approximated using only a few dose levels but only if both the compartment boundaries and prescribed dose levels are well chosen.

  9. [Dose-Response Dependences for Frequency of RET/PTC Gene Rearrangements in Papillary Thyroid Carcinoma after Irradiation. Simple Pooling Analysis of Molecular Epidemiological Data].

    Science.gov (United States)

    Koterov, A N; Ushenkova, L N; Biryukov, A P

    2016-01-01

    On the basis of all possible publications on the theme included in the previously formed base of sources on molecular epidemiology of RET/PTC rearrangements in thyroid papillary carcinoma a pooled analysis ("simple pooling data") on determination of the dose-effect dependences for RET/PTC frequency in radiogenic carcinomas of various irradiated groups was performed. (They are groups subjected to radiotherapeutic exposure, residents near the Chernobyl nuclear power plant (CNPP) and victims of nuclear bombing). The tendency to Pearson linear correlation (r = 0.746; p = 0.148) between the frequency of RET/PTC and the estimated dose on thyroid in the regions affected by the CNPP accident was revealed. But this tendency was recognized to be random owing to abnormally low values of the indicator for the most contaminated Gomel region. The method tentatively called "case-control" showed reliable differences in thyroid dose values for carcinomas with RET/PTC and without those. The versatility of changes was found: the lack of RET/PTC for radiotherapeutic impacts was associated with higher doses, whereas in case of the CNPP accident and for nuclear bombing victims it was the opposite. Probably, in the first case the "cellular cleaning" phenomenon after exposure to very high doses took place. Search of direct Pearson correlations between average/median thyroid doses on groups and RET/PTC frequency in carcinomas of these groups showed a high reliability for the dose-effect dependences- at the continuous dose scale (for RET/PTC in total and RET/PTC1 respectively: r = 0.830; p = 0.002 and r = 0.906; p = 0.0003); while there was no significant correlation received for RET/PTC3. When using the weighting least square regression analysis (proceeding from the number of carcinomas in samples), the specified regularities remained. Attempts to influence the strength of correlation by exception ofthe data of all the samples connected with the accident on the CNPP did not significantly

  10. Application of the dose rate spectroscopy to the dose-to-curie conversion method using a NaI(Tl) detector

    International Nuclear Information System (INIS)

    JI, Young-Yong; Chung, Kun Ho; Kim, Chang-Jong; Kang, Mun Ja; Park, Sang Tae

    2015-01-01

    Dose rate spectroscopy is a very useful method to directly calculate the individual dose rate from the converted energy spectrum for the dose rate using the G-factor which is related to the used detector response function. A DTC conversion method for the estimation of the radioactivity based on the measured dose rate from the radioactive materials can then be modified into a simple equation using the dose rate spectroscopy. In order to make the method validation of the modified DTC conversion method, experimental verifications using a 3″φx3″ NaI(Tl) detector were conducted at the simple geometry of the point source located onto a detector and more complex geometries which mean the assay of the simulated radioactive material. In addition, the linearity about the results from the modified DTC conversion method was also estimated by increasing the distance between source positions and a detector to confirm the method validation in the energy, dose rate, and distance range of the gamma nuclides. - Highlights: • A modified DTC conversion method using the dose rate spectroscopy was established. • In-situ calibration factors were calculated from the MCNP simulation. • Radioactivities of the disk sources were accurately calculated using a modified DTC conversion method. • A modified DTC conversion method was applied to the assay of the radioactive material

  11. Management of temporary urinary retention after arthroscopic knee surgery in low-dose spinal anesthesia: development of a simple algorithm.

    Science.gov (United States)

    Luger, Thomas J; Garoscio, Ivo; Rehder, Peter; Oberladstätter, Jürgen; Voelckel, Wolfgang

    2008-06-01

    In practice, trauma and orthopedic surgery during spinal anesthesia are often performed with routine urethral catheterization of the bladder to prevent an overdistention of the bladder. However, use of a catheter has inherent risks. Ultrasound examination of the bladder (Bladderscan) can precisely determine the bladder volume. Thus, the aim of this study was to identify parameters indicative of urinary retention after low-dose spinal anesthesia and to develop a simple algorithm for patient care. This prospective pilot study approved by the Ethics Committee enrolled 45 patients after obtaining their written informed consent. Patients who underwent arthroscopic knee surgery received low-dose spinal anesthesia with 1.4 ml 0.5% bupivacaine at level L3/L4. Bladder volume was measured by urinary bladder scanning at baseline, at the end of surgery and up to 4 h later. The incidence of spontaneous urination versus catheterization was assessed and the relative risk for catheterization was calculated. Mann-Whitney test, chi(2) test with Fischer Exact test and the relative odds ratio were performed as appropriate. *P 300 ml postoperatively had a 6.5-fold greater likelihood for urinary retention. In the management of patients with short-lasting spinal anesthesia for arthroscopic knee surgery we recommend monitoring bladder volume by Bladderscan instead of routine catheterization. Anesthesiologists or nurses under protocol should assess bladder volume preoperatively and at the end of surgery. If bladder volume is >300 ml, catheterization should be performed in the OR. Patients with a bladder volume of 500 ml.

  12. In-vivo (entrance) dose measurements in external beam radiotherapy with aqueous FBX dosimetry system

    International Nuclear Information System (INIS)

    Semwal, M.K.; Thakur, P.K.; Bansal, A.K.; Vidyasagar, P.B.

    2005-01-01

    FBX aqueous chemical dosimetry system has been found useful in radiotherapy owing to its low dose measuring capability. In the present work, entrance dose measurements in external beam radiotherapy on a telecobalt machine were carried out with the system on 100 patients. Treatments involving simple beam arrangement of open parallel-opposed beams in cranial and pelvic irradiations were selected for this study. In place of a spectrophotometer, a simple and inexpensive colorimeter was used for absorbance measurements. The purpose was to assess the efficacy of the FBX system for in-vivo dose measurements. The results obtained show that the average discrepancy between the measured and expected dose for both categories of patients was 0.2% (standard deviation 3.2%) with a maximum of +1 0.3%. There were 5.5% cases showing more than ± 5% discrepancy. Comparison of the results obtained with published work on entrance dose measurements, with diode detectors, shows that the inexpensive FBX system can be used for in-vivo (entrance) dose measurements for simple beam arrangements in radiotherapy and can thus serve as a useful QA tool. (author)

  13. A dose error evaluation study for 4D dose calculations

    Science.gov (United States)

    Milz, Stefan; Wilkens, Jan J.; Ullrich, Wolfgang

    2014-10-01

    Previous studies have shown that respiration induced motion is not negligible for Stereotactic Body Radiation Therapy. The intrafractional breathing induced motion influences the delivered dose distribution on the underlying patient geometry such as the lung or the abdomen. If a static geometry is used, a planning process for these indications does not represent the entire dynamic process. The quality of a full 4D dose calculation approach depends on the dose coordinate transformation process between deformable geometries. This article provides an evaluation study that introduces an advanced method to verify the quality of numerical dose transformation generated by four different algorithms. The used transformation metric value is based on the deviation of the dose mass histogram (DMH) and the mean dose throughout dose transformation. The study compares the results of four algorithms. In general, two elementary approaches are used: dose mapping and energy transformation. Dose interpolation (DIM) and an advanced concept, so called divergent dose mapping model (dDMM), are used for dose mapping. The algorithms are compared to the basic energy transformation model (bETM) and the energy mass congruent mapping (EMCM). For evaluation 900 small sample regions of interest (ROI) are generated inside an exemplary lung geometry (4DCT). A homogeneous fluence distribution is assumed for dose calculation inside the ROIs. The dose transformations are performed with the four different algorithms. The study investigates the DMH-metric and the mean dose metric for different scenarios (voxel sizes: 8 mm, 4 mm, 2 mm, 1 mm 9 different breathing phases). dDMM achieves the best transformation accuracy in all measured test cases with 3-5% lower errors than the other models. The results of dDMM are reasonable and most efficient in this study, although the model is simple and easy to implement. The EMCM model also achieved suitable results, but the approach requires a more complex

  14. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    International Nuclear Information System (INIS)

    Oliveira, Jetro Pereira de; Batista, Delano Valdivino Santos; Bardella, Lucia Helena; Carvalho, Arnaldo Rangel

    2009-01-01

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  15. A simple method of dosimetry for E-beam radiation

    International Nuclear Information System (INIS)

    Spencer, D.S.; Thalacker, V.P.; Chasman, J.N.; Siegel, S.

    1985-01-01

    A simple method utilizing a photochromic 'intensity label' for monitoring electron-beam sources was evaluated. The labels exhibit a color change upon exposure to UV or e-beam radiation. A correlation was found between absorbed energy and Gardner Color Index at low electron-beam doses. (author)

  16. Dose from radiological examinations

    International Nuclear Information System (INIS)

    Imamura, Keiko; Uji, Teruyuki; Sakuyama, Keiko; Fujikawa, Mitsuhiro; Fujii, Masamichi

    1976-01-01

    Relatively high gonad doses, several hundred to one thousand mR, have been observed in case of pelvis, hip-joint, coccyx, lower abdomen and lumber examination. Dose to the ovary is especially high in barium enema and I.V.P. examinations. About 12 per cent of the 4-ray examination are high-dose. The gonad dose is relatively high in examination of abdomen and lower extremities, in infants. The dose to the eyes is especially high, 1.0 to 2.5R per exposure, in temporal bone and nasal sinuses tomography. X-ray doses have been compared with dose limits recommended by ICRP and with the gonad dose from natural radiations. The gonad dose in lumbar examination, barium enema, I.V.P. etc. is as high as the maximum permissible dose per year recommended by ICRP. Several devices have been made for dose reduction in the daily examinations: (1) separating the radiation field from the gonad by one centimeter decreases the gonad dose about one-half. (2) using sensitive screens and films. In pelvimetry and in infant hip-joint examination, the most sensitive screen and film are used. In the I.V.P. examination of adult, use of MS screen in place of FS screen decreases the dose to one-third, in combination with careful setting of radiation field, (3) use of grid increases the dose about 50 percent and the lead rubber protection (0.1mm lead equivalent) decreases the gonad dose to one-thirtieth in the spinal column examination of infant, (4) A lead protector, 1mm thickness and 2.5cm in diameter, on the eyes decreases the dose to about one-eighth in the face and nead examinations. These simple and effective methods for dose reduction. Should be carried out in as many examinations as possible in addition to observing dose limits recommended by ICRP. (Evans, J.)

  17. Dose reconstruction using mobile phones

    International Nuclear Information System (INIS)

    Beerten, K.; Reekmans, F.; Schroeyers, W.; Lievens, L.; Vanhavere, F.

    2011-01-01

    Electronic components inside mobile phones are regarded as useful tools for accident and retrospective dosimetry using optically stimulated luminescence (OSL) and thermoluminescence. Components inside the devices with suitable properties for luminescence dosimetry include, amongst others, ceramic substrates in resistors, capacitors, transistors and antenna switches. Checking the performance of such devices in dosimetric experiments is a crucial step towards developing a reliable dosimetry system for emergency situations using personal belongings. Here, the results of dose assessment experiments using irradiated mobile phones are reported. It will be shown that simple regenerative dose estimates, derived from various types of components removed from different mobile phone models, are consistent with the given dose, after applying an average fading correction factor. (authors)

  18. Análisis de regresión simple

    OpenAIRE

    Rodríguez Jaume, María José; Mora Catalá, Rafael

    2001-01-01

    El análisis de regresión lineal, en general, nos permite obtener una función lineal de una o más variables independientes o predictoras (X1, X2, ... XK) a partir de la cual explicar o predecir el valor de una variable dependiente o criterio (Y). La lección la hemos estructurado en los siguientes puntos: 1. Exposición de los estadísticos que nos permiten valoración de la bondad de ajuste de los datos al modelo de regresión lineal simple; 2. Si los estadísticos certifican que entre los datos se...

  19. A three-dimensional dose-distribution estimation system using computerized image reconstruction

    International Nuclear Information System (INIS)

    Nishijima, Akihiko; Kidoya, Eiji; Komuro, Hiroyuki; Tanaka, Masato; Asada, Naoki.

    1990-01-01

    In radiotherapy planning, three dimensional (3-D) estimation of dose distribution has been very troublesome and time-consuming. To solve this problem, a simple and fast 3-D dose distribution image using a computer and Charged Couple Device (CCD) camera was developed. A series of X-ray films inserted in the phantom using a linear accelerator unit was exposed. The degree of film density was degitized with a CCD camera and a minicomputer (VAX 11-750). After that these results were compared with the present depth dose obtained by a JARP type dosimeter, with a dose error being less than 2%. The 3-D dose distribution image could accurately depict the density changes created by aluminum and air put into the phantom. The contrast resolution of the CCD camera seemed to be superior to the convention densitometer in the low-to-intermediate contrast range. In conclusion, our method seem to be very fast and simple for obtaining 3-D dose distribution images and is very effective when compared with the conventional method. (author)

  20. Chromosomal Aberrations in DNA Repair Defective Cell Lines: Comparisons of Dose Rate and Radiation Quality

    Science.gov (United States)

    George, K. A.; Hada, M.; Patel, Z.; Huff, J.; Pluth, J. M.; Cucinotta, F. A.

    2009-01-01

    Chromosome aberration yields were assessed in DNA double-strand break repair (DSB) deficient cells after acute doses of gamma-rays or high-LET iron nuclei, or low dose-rate (0.018 Gy/hr) gamma-rays. We studied several cell lines including fibroblasts deficient in ATM (product of the gene that is mutated in ataxia telangiectasia patients) or NBS (product of the gene mutated in the Nijmegen breakage syndrome), and gliomablastoma cells that are proficient or lacking in DNA-dependent protein kinase, DNA-PK activity. Chromosomes were analyzed using the fluorescence in-situ hybridization (FISH) chromosome painting method in cells at the first division post-irradiation and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). Gamma radiation induced higher yields of both simple and complex exchanges in the DSB repair defective cells than in the normal cells. The quadratic dose-response terms for both chromosome exchange types were significantly higher for the ATM and NBS defective lines than for normal fibroblasts. However, the linear dose-response term was significantly higher only for simple exchanges in the NBS cells. Large increases in the quadratic dose response terms indicate the important roles of ATM and NBS in chromatin modifications that facilitate correct DSB repair and minimize aberration formation. Differences in the response of AT and NBS deficient cells at lower doses suggests important questions about the applicability of observations of radiation sensitivity at high dose to low dose exposures. For all iron nuclei irradiated cells, regression models preferred purely linear and quadratic dose responses for simple and complex exchanges, respectively. All the DNA repair defective cell lines had lower Relative biological effectiveness (RBE) values than normal cells, the lowest being for the DNA-PK-deficient cells, which was near unity. To further

  1. Bone marrow equivalent prompt dose from two common fallout scenarios

    International Nuclear Information System (INIS)

    Morris, M.D.; Jones, T.D.; Young, R.W.

    1994-01-01

    A cell-kinetics model for radiation-induced myelopoiesis has been derived for mice, rats, dogs, sheep, swine, and burros. The model was extended to humans after extensive comparisons with molecular and cellular data from biological experiments and an assortment of predictive/validation tests on animal mortality, cell survival, and cellular repopulation following irradiations. One advantage of the model is that any complex pattern of protracted irradiation can be equated to its equivalent prompt dose. Severity of biological response depends upon target-organ dose, dose rate, and dose fractionation. Epidemiological and animal data are best suited for exposures given in brief periods of time. To use those data to assess risk from protracted human exposures, it is obligatory to model molecular repair and compensatory proliferation in terms of prompt dose. Although the model is somewhat complex both mathematically and biologically, this note describes simple numerical approximations for two common exposure scenarios. Both approximations are easily evaluated on a simple pocket calculator by a health physicist or emergency management officer. 12 refs., 5 figs

  2. Effets Josephson generalises entre antiferroaimants et entre supraconducteurs antiferromagnetiques

    Science.gov (United States)

    Chasse, Dominique

    L'effet Josephson est generalement presente comme le resultat de l'effet tunnel coherent de paires de Cooper a travers une jonction tunnel entre deux supraconducteurs, mais il est possible de l'expliquer dans un contexte plus general. Par exemple, Esposito & al. ont recemment demontre que l'effet Josephson DC peut etre decrit a l'aide du boson pseudo-Goldstone de deux systemes couples brisant chacun la symetrie abelienne U(1). Puisque cette description se generalise de facon naturelle a des brisures de symetries continues non-abeliennes, l'equivalent de l'effet Josephson devrait donc exister pour des types d'ordre a longue portee differents de la supraconductivite. Le cas de deux ferroaimants itinerants (brisure de symetrie 0(3)) couples a travers une jonction tunnel a deja ete traite dans la litterature Afin de mettre en evidence la generalite du phenomene et dans le but de faire des predictions a partir d'un modele realiste, nous etudions le cas d'une jonction tunnel entre deux antiferroaimants itinerants. En adoptant une approche Similaire a celle d'Ambegaokar & Baratoff pour une jonction Josephson, nous trouvons un courant d'aimantation alternee a travers la jonction qui est proportionnel a sG x sD ou fG et sD sont les vecteurs de Neel de part et d'autre de la jonction. La fonction sinus caracteristique du courant Josephson standard est donc remplacee.ici par un produit vectoriel. Nous montrons que, d'un point de vue microscopique, ce phenomene resulte de l'effet tunnel coherent de paires particule-trou de spin 1 et de vecteur d'onde net egal au vecteur d'onde antiferromagnetique Q. Nous trouvons egalement la dependance en temperature de l'analogue du courant critique. En presence d'un champ magnetique externe, nous obtenons l'analogue de l'effet Josephson AC et la description complete que nous en donnons s'applique aussi au cas d'une jonction tunnel entre ferroaimants (dans ce dernier cas, les traitements anterieurs de cet effet AC s'averent incomplets). Nous

  3. Asociación entre enfermedad cardiovascular y anticuerpos contra Chlamydia pneumoniae

    Directory of Open Access Journals (Sweden)

    García-Elorriaga Guadalupe de los A

    2002-01-01

    Full Text Available Objetivo. Precisar si existe asociación entre enfermedad cardiovascular (ECV y anticuerpos contra Chlamydia en población mexicana. Material y métodos. Estudio transversal, realizado en la Unidad de Investigación en Inmunología e Infectología -Hospital de Infectología del Centro Médico Nacional La Raza (CMNR- y en el Servicio de Cirugía Cardiovascular y Asistencia Circulatoria, del Hospital General del CMNR, Instituto Mexicano del Seguro Social (IMSS, de agosto de 1998 a abril de 2000. Se determinaron anticuerpos IgG e IgM contra C. psittaci, C. trachomatis y C. pneumoniae mediante microinmunofluorescencia, en suero de 70 pacientes con ECV hospitalizados en el CMNR, mayores de 30 años, de uno u otro sexo, y se compararon con 140 sanos, pareados por edad y sexo. Se utilizaron muestras aleatorias simples, con un tamaño poblacional de 110, una prevalencia de 50% y un nivel de confianza de 99%. Para establecer la diferencia entre las proporciones de los títulos se utilizó ji cuadrada y se calculó la razón de momios. Resultados. El 94.3% (66/70 de los pacientes presentó IgG en contra de C. pneumoniae vs 37% (52/140 de los individuos sanos (p<0.001. Conclusiones. Existe una fuerte asociación entre anticuerpos IgG hacia C. pneumoniae y ECV.

  4. Simple screen for minimising radiation doses to nursing staff involved in nuclear medicine procedures

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, A; Brown, L D [Aberdeen Univ. (UK)

    1979-05-01

    Nursing staff are exposed to doses typically of the order of 3.5 mrad h/sup -1/ while holding patients steady for gamma camera scans. A special screen has been designed and constructed for their use. The shield, consisting of 3 mm lead sheet sandwiched between aluminium sheets each 2 mm thick, is mobile since it is mounted on large ball castors. The use of the shield reduced the gonad dose to nurses per examination from 1.7 to 0.20 mrad.

  5. Interações farmacocinéticas entre as plantas medicinais Hypericum perforatum, Gingko bilobae Panax gingseng e fármacos tradicionais

    OpenAIRE

    de Oliveira, Ana Elisa; Dalla Costa, Teresa

    2004-01-01

    Como o uso de plantas medicinais tem se popularizado, sendo comum sua utilização como complemento aos tratamentos convencionais, a falta de conhecimento sobre interações entre fármacos e plantas medicinais põem em risco a saúde dos usuários. Neste artigo é apresentada uma revisão de literatura sobre interações farmacocinéticas entre fármacos e plantas medicinais utilizadas no Brasil como Hypericum perforatum, Gingko biloba e Panax ginseng. O ajuste da dose recomendada do fármaco d...

  6. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer; Avaliacao da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jetro Pereira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina; Rosa, Luiz Antonio Ribeiro da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], e-mail: lrosa@ird.gov.br; Batista, Delano Valdivino Santos; Bardella, Lucia Helena [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil). Unit of Medical Physics; Carvalho, Arnaldo Rangel [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. of Thermoluminescent Dosimetry

    2009-03-15

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  7. Simple method to estimate mean heart dose from Hodgkin lymphoma radiation therapy according to simulation X-rays.

    Science.gov (United States)

    van Nimwegen, Frederika A; Cutter, David J; Schaapveld, Michael; Rutten, Annemarieke; Kooijman, Karen; Krol, Augustinus D G; Janus, Cécile P M; Darby, Sarah C; van Leeuwen, Flora E; Aleman, Berthe M P

    2015-05-01

    To describe a new method to estimate the mean heart dose for Hodgkin lymphoma patients treated several decades ago, using delineation of the heart on radiation therapy simulation X-rays. Mean heart dose is an important predictor for late cardiovascular complications after Hodgkin lymphoma (HL) treatment. For patients treated before the era of computed tomography (CT)-based radiotherapy planning, retrospective estimation of radiation dose to the heart can be labor intensive. Patients for whom cardiac radiation doses had previously been estimated by reconstruction of individual treatments on representative CT data sets were selected at random from a case-control study of 5-year Hodgkin lymphoma survivors (n=289). For 42 patients, cardiac contours were outlined on each patient's simulation X-ray by 4 different raters, and the mean heart dose was estimated as the percentage of the cardiac contour within the radiation field multiplied by the prescribed mediastinal dose and divided by a correction factor obtained by comparison with individual CT-based dosimetry. According to the simulation X-ray method, the medians of the mean heart doses obtained from the cardiac contours outlined by the 4 raters were 30 Gy, 30 Gy, 31 Gy, and 31 Gy, respectively, following prescribed mediastinal doses of 25-42 Gy. The absolute-agreement intraclass correlation coefficient was 0.93 (95% confidence interval 0.85-0.97), indicating excellent agreement. Mean heart dose was 30.4 Gy with the simulation X-ray method, versus 30.2 Gy with the representative CT-based dosimetry, and the between-method absolute-agreement intraclass correlation coefficient was 0.87 (95% confidence interval 0.80-0.95), indicating good agreement between the two methods. Estimating mean heart dose from radiation therapy simulation X-rays is reproducible and fast, takes individual anatomy into account, and yields results comparable to the labor-intensive representative CT-based method. This simpler method may produce a

  8. Simple Method to Estimate Mean Heart Dose From Hodgkin Lymphoma Radiation Therapy According to Simulation X-Rays

    Energy Technology Data Exchange (ETDEWEB)

    Nimwegen, Frederika A. van [Department of Psychosocial Research, Epidemiology, and Biostatistics, The Netherlands Cancer Institute, Amsterdam (Netherlands); Cutter, David J. [Clinical Trial Service Unit, University of Oxford, Oxford (United Kingdom); Oxford Cancer Centre, Oxford University Hospitals NHS Trust, Oxford (United Kingdom); Schaapveld, Michael [Department of Psychosocial Research, Epidemiology, and Biostatistics, The Netherlands Cancer Institute, Amsterdam (Netherlands); Rutten, Annemarieke [Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Kooijman, Karen [Department of Psychosocial Research, Epidemiology, and Biostatistics, The Netherlands Cancer Institute, Amsterdam (Netherlands); Krol, Augustinus D.G. [Department of Radiation Oncology, Leiden University Medical Center, Leiden (Netherlands); Janus, Cécile P.M. [Department of Radiation Oncology, Erasmus MC Cancer Center, Rotterdam (Netherlands); Darby, Sarah C. [Clinical Trial Service Unit, University of Oxford, Oxford (United Kingdom); Leeuwen, Flora E. van [Department of Psychosocial Research, Epidemiology, and Biostatistics, The Netherlands Cancer Institute, Amsterdam (Netherlands); Aleman, Berthe M.P., E-mail: b.aleman@nki.nl [Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2015-05-01

    Purpose: To describe a new method to estimate the mean heart dose for Hodgkin lymphoma patients treated several decades ago, using delineation of the heart on radiation therapy simulation X-rays. Mean heart dose is an important predictor for late cardiovascular complications after Hodgkin lymphoma (HL) treatment. For patients treated before the era of computed tomography (CT)-based radiotherapy planning, retrospective estimation of radiation dose to the heart can be labor intensive. Methods and Materials: Patients for whom cardiac radiation doses had previously been estimated by reconstruction of individual treatments on representative CT data sets were selected at random from a case–control study of 5-year Hodgkin lymphoma survivors (n=289). For 42 patients, cardiac contours were outlined on each patient's simulation X-ray by 4 different raters, and the mean heart dose was estimated as the percentage of the cardiac contour within the radiation field multiplied by the prescribed mediastinal dose and divided by a correction factor obtained by comparison with individual CT-based dosimetry. Results: According to the simulation X-ray method, the medians of the mean heart doses obtained from the cardiac contours outlined by the 4 raters were 30 Gy, 30 Gy, 31 Gy, and 31 Gy, respectively, following prescribed mediastinal doses of 25-42 Gy. The absolute-agreement intraclass correlation coefficient was 0.93 (95% confidence interval 0.85-0.97), indicating excellent agreement. Mean heart dose was 30.4 Gy with the simulation X-ray method, versus 30.2 Gy with the representative CT-based dosimetry, and the between-method absolute-agreement intraclass correlation coefficient was 0.87 (95% confidence interval 0.80-0.95), indicating good agreement between the two methods. Conclusion: Estimating mean heart dose from radiation therapy simulation X-rays is reproducible and fast, takes individual anatomy into account, and yields results comparable to the labor

  9. Manual of dose evaluation from atmospheric releases

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Abrol, V [Health Physics Division, Bhabha Atomic Research Centre, Bombay (India)

    1978-07-01

    The problem of dose evaluation from atmospheric releases is reduced to simple arithmetic by giving tables of concentrations and time integrated concentrations for instantaneous plumes and long time (1 year), sector averaged plumes for distances upto 10 km, effective release heights of upto 200 m and the six Pasquill stability classes. Correction factors for decay, depletion due to deposition and rainout are also given. Inhalation doses, immersion doses and contamination levels can be obtained from these by using multiplicative factors tabulated for various isotopes of significance. Tables of external gamma doses from plume are given separately for various gamma energies. Tables are also given to evaluate external beta and gamma dose rates from contaminated surfaces. The manual also discusses the basic diffusion model relevant to the problem. (author)

  10. On the application of a simple model of cobalt-60 beams

    International Nuclear Information System (INIS)

    Gantchew, M.G.

    1979-01-01

    The simple mathematical model of the dose distribution in a phantom irradiated by a single beam of cobalt-60 gamma rays (Wilks, R.J., and Sutcliffe, J.F., 1977, Phys. Med. Biol., vol. 22, 737) requires measurements for each particular field size and diaphragm setting to describe the decrement functions (dose distributions along a straight line perpendicular to the central ray). Measurements made with a Gammatron-3 have shown satisfactory agreement between computed and measured lateral dose distributions for different diaphragm settings if the experimental data was first subjected to additional processing, and Wilks and Sutcliffe's model can therefore be applied to any diaphragm setting using this modification. Field sizes can therefore be entered according to diaphragm indicator reading in dose planning. (U.K.)

  11. Superficial dose evaluation of four dose calculation algorithms

    Science.gov (United States)

    Cao, Ying; Yang, Xiaoyu; Yang, Zhen; Qiu, Xiaoping; Lv, Zhiping; Lei, Mingjun; Liu, Gui; Zhang, Zijian; Hu, Yongmei

    2017-08-01

    Accurate superficial dose calculation is of major importance because of the skin toxicity in radiotherapy, especially within the initial 2 mm depth being considered more clinically relevant. The aim of this study is to evaluate superficial dose calculation accuracy of four commonly used algorithms in commercially available treatment planning systems (TPS) by Monte Carlo (MC) simulation and film measurements. The superficial dose in a simple geometrical phantom with size of 30 cm×30 cm×30 cm was calculated by PBC (Pencil Beam Convolution), AAA (Analytical Anisotropic Algorithm), AXB (Acuros XB) in Eclipse system and CCC (Collapsed Cone Convolution) in Raystation system under the conditions of source to surface distance (SSD) of 100 cm and field size (FS) of 10×10 cm2. EGSnrc (BEAMnrc/DOSXYZnrc) program was performed to simulate the central axis dose distribution of Varian Trilogy accelerator, combined with measurements of superficial dose distribution by an extrapolation method of multilayer radiochromic films, to estimate the dose calculation accuracy of four algorithms in the superficial region which was recommended in detail by the ICRU (International Commission on Radiation Units and Measurement) and the ICRP (International Commission on Radiological Protection). In superficial region, good agreement was achieved between MC simulation and film extrapolation method, with the mean differences less than 1%, 2% and 5% for 0°, 30° and 60°, respectively. The relative skin dose errors were 0.84%, 1.88% and 3.90%; the mean dose discrepancies (0°, 30° and 60°) between each of four algorithms and MC simulation were (2.41±1.55%, 3.11±2.40%, and 1.53±1.05%), (3.09±3.00%, 3.10±3.01%, and 3.77±3.59%), (3.16±1.50%, 8.70±2.84%, and 18.20±4.10%) and (14.45±4.66%, 10.74±4.54%, and 3.34±3.26%) for AXB, CCC, AAA and PBC respectively. Monte Carlo simulation verified the feasibility of the superficial dose measurements by multilayer Gafchromic films. And the rank

  12. A simple model for the microstructural evolution of solids under irradiation

    International Nuclear Information System (INIS)

    Valentin, P.P.; Martin, G.

    1982-01-01

    The coupled evolutions of the void and dislocation populations in crystals under high-temperature irradiation are studied by a simple heuristic theoretical approach: rate equations are used for describing both defect concentrations and microstructural variables, and the trajectories of the point representative of the microstructure in the appropriate state space are studied. Qualitatively different microstructural evolutions are found depending on the irradiation flux and temperature. Non-trivial behaviours are revealed such as: transient swelling, effect of cold work on the incubation dose for swelling, large dose divergence of evolutions which looked similar at low dose (which should result in large swelling heterogeneities) and radiation-enhanced sintering. (author)

  13. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  14. Influence of dose and its distribution in time on dose-response relationships for low-LET radiation

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This book examines the influence of dose rate and magnitude on the genetic and carcinogenic effects of radiation exposure in animals and man. It systematically examines a broad range of biological effects in simple systems, plants, laboratory animals, and man with special attention given to the effects of prenatal irradiation, changes in life span, and tumorigenesis. An enormous volume of data is provided about human tumorigenesis and the data and shortcomings are summarized. There is an extended general discussion of the consideration in quantitative dose and dose rate relationships and of the limitations of the data and analyses which have led to a linear interpolation of risk at low doses and dose rates. An argument is made for dose rate dependence in tumorigenesis as being consistent with all other radiation effects and for the applicability of Dose Rate Effectiveness Factors (DREF) in providing a more realistic assessment of the risk of radiation carcinogenesis. The report is documented with 24 pages of references. There are numerous graphs and tables, all clear and to the point. This book is a superb review and summary of the data on radiation risks

  15. Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry

    International Nuclear Information System (INIS)

    Tomasevic, M.; Radovanovic, R.

    1986-01-01

    During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author)

  16. Produção e qualidade de alho sob regimes de água no solo e doses de nitrogênio

    Directory of Open Access Journals (Sweden)

    Marouelli Waldir A.

    2002-01-01

    Full Text Available Avaliou-se os efeitos de regimes de água no solo e doses de nitrogênio (N sobre a produção e qualidade de bulbos de uma cultivar de alho suscetível ao pseudoperfilhamento. O estudo foi conduzido na Embrapa Hortaliças, Brasília, e os tratamentos consistiram da combinação de três tensões de água (15; 35 e 70 kPa e três doses de N (20; 100 e 500 kg.ha-1. Maior desenvolvimento vegetativo, produtividade total e massa média de bulbos foram obtidos para tensões entre 15 e 19 kPa e doses de N entre 52 e 97 kg.ha-1. A produtividade comercial foi maximizada para a tensão de 15 kPa, sendo contudo reduzida linearmente com o aumento da dose de N. A porcentagem de bulbos pseudoperfilhados foi influenciada pela tensão de água, dose de N e pela interação dos fatores, tendo sido minimizada para a tensão de 70 kPa e 20 kg.ha-1 de N. As porcentagens de bulbos chochos e de perda de massa entre 60 e 120 dias após a colheita aumentaram linearmente com as doses de N, mas não foram afetadas pela tensão. Assim, para maximizar a produtividade comercial de cultivares suscetíveis ao pseudoperfilhamento deve-se realizar a irrigação em regime de alta freqüência, mesmo favorecendo maior porcentagem de pseudobulbos, e minimizar a aplicação de N.

  17. Converting dose distributions into tumour control probability

    International Nuclear Information System (INIS)

    Nahum, A.E.

    1996-01-01

    The endpoints in radiotherapy that are truly of relevance are not dose distributions but the probability of local control, sometimes known as the Tumour Control Probability (TCP) and the Probability of Normal Tissue Complications (NTCP). A model for the estimation of TCP based on simple radiobiological considerations is described. It is shown that incorporation of inter-patient heterogeneity into the radiosensitivity parameter a through s a can result in a clinically realistic slope for the dose-response curve. The model is applied to inhomogeneous target dose distributions in order to demonstrate the relationship between dose uniformity and s a . The consequences of varying clonogenic density are also explored. Finally the model is applied to the target-volume DVHs for patients in a clinical trial of conformal pelvic radiotherapy; the effect of dose inhomogeneities on distributions of TCP are shown as well as the potential benefits of customizing the target dose according to normal-tissue DVHs. (author). 37 refs, 9 figs

  18. Converting dose distributions into tumour control probability

    Energy Technology Data Exchange (ETDEWEB)

    Nahum, A E [The Royal Marsden Hospital, London (United Kingdom). Joint Dept. of Physics

    1996-08-01

    The endpoints in radiotherapy that are truly of relevance are not dose distributions but the probability of local control, sometimes known as the Tumour Control Probability (TCP) and the Probability of Normal Tissue Complications (NTCP). A model for the estimation of TCP based on simple radiobiological considerations is described. It is shown that incorporation of inter-patient heterogeneity into the radiosensitivity parameter a through s{sub a} can result in a clinically realistic slope for the dose-response curve. The model is applied to inhomogeneous target dose distributions in order to demonstrate the relationship between dose uniformity and s{sub a}. The consequences of varying clonogenic density are also explored. Finally the model is applied to the target-volume DVHs for patients in a clinical trial of conformal pelvic radiotherapy; the effect of dose inhomogeneities on distributions of TCP are shown as well as the potential benefits of customizing the target dose according to normal-tissue DVHs. (author). 37 refs, 9 figs.

  19. Analysis of CT radiation dose based on radiation-dose-structured reports

    International Nuclear Information System (INIS)

    Wang Weipeng; Zhang Yi; Zhang Menglong; Zhang Dapeng; Song Shaojuan

    2014-01-01

    Objective: To analyse the CT radiation dose statistically using the standardized radiation-dose-structured report (RDSR) of digital imaging and communications in medicine (DICOM). Methods: Using the self-designed software, 1230 RDSR files about CT examination were obtained searching on the picture archiving and communication system (PACS). The patient dose database was established by combination of the extracted relevant information with the scanned sites. The patients were divided into adult group (over 10 years) and child groups (0-1 year, 1-5 years, 5-10 years) according to the age. The average volume CT dose index (CTDI vol ) and dose length product (DLP) of all scans were recorded respectively, and then the effective dose (E) was estimated. The DLP value at 75% quantile was calculated and compared with the diagnostic reference level (DRL). Results: In adult group, CTDI vol and DLP values were moderately and positively correlated (r = 0.41), the highest E was observed in upper abdominal enhanced scan, and the DLP value at 75% quantile was 60% higher than DRL. In child group, their CTDI vol in group of 5-10 years was greater than that in groups of 0-1 and 1-5 years (t = 2.42, 2.04, P < 0.05); the DLP value was slightly and positively correlated with the age (r = 0.16), while E was moderately and negatively correlated with the age (r = -0.48). Conclusions: It is a simple and efficient method to use RDSR to obtain the radiation doses of patients. With the popularization of the new equipment and the application of regionalized medical platform, RDSR would become the main tool for the dosimetric level surveying and individual dose recording. (authors)

  20. Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancer

    International Nuclear Information System (INIS)

    Mu, G; Ludlum, E; Xia, P

    2008-01-01

    The dosimetric impact of random and systematic multi-leaf collimator (MLC) leaf position errors is relatively unknown for head and neck intensity-modulated radiotherapy (IMRT) patients. In this report we studied 17 head and neck IMRT patients, including 12 treated with simple plans ( 100 segments). Random errors (-2 to +2 mm) and systematic errors (±0.5 mm and ±1 mm) in MLC leaf positions were introduced into the clinical plans and the resultant dose distributions were analyzed based on defined endpoint doses. The dosimetric effect was insignificant for random MLC leaf position errors up to 2 mm for both simple and complex plans. However, for systematic MLC leaf position errors, we found significant dosimetric differences between the simple and complex IMRT plans. For 1 mm systematic error, the average changes in D 95% were 4% in simple plans versus 8% in complex plans. The average changes in D 0.1cc of the spinal cord and brain stem were 4% in simple plans versus 12% in complex plans. The average changes in parotid glands were 9% in simple plans versus 13% for the complex plans. Overall, simple IMRT plans are less sensitive to leaf position errors than complex IMRT plans

  1. Small field depth dose profile of 6 MV photon beam in a simple air-water heterogeneity combination: A comparison between anisotropic analytical algorithm dose estimation with thermoluminescent dosimeter dose measurement.

    Science.gov (United States)

    Mandal, Abhijit; Ram, Chhape; Mourya, Ankur; Singh, Navin

    2017-01-01

    To establish trends of estimation error of dose calculation by anisotropic analytical algorithm (AAA) with respect to dose measured by thermoluminescent dosimeters (TLDs) in air-water heterogeneity for small field size photon. TLDs were irradiated along the central axis of the photon beam in four different solid water phantom geometries using three small field size single beams. The depth dose profiles were estimated using AAA calculation model for each field sizes. The estimated and measured depth dose profiles were compared. The over estimation (OE) within air cavity were dependent on field size (f) and distance (x) from solid water-air interface and formulated as OE = - (0.63 f + 9.40) x2+ (-2.73 f + 58.11) x + (0.06 f2 - 1.42 f + 15.67). In postcavity adjacent point and distal points from the interface have dependence on field size (f) and equations are OE = 0.42 f2 - 8.17 f + 71.63, OE = 0.84 f2 - 1.56 f + 17.57, respectively. The trend of estimation error of AAA dose calculation algorithm with respect to measured value have been formulated throughout the radiation path length along the central axis of 6 MV photon beam in air-water heterogeneity combination for small field size photon beam generated from a 6 MV linear accelerator.

  2. Radiochromic film as a radiotherapy surface-dose detector

    International Nuclear Information System (INIS)

    Butson, M.J.; Metcalfe, P.E.; Wollongong Univ., NSW; Mathur, J.N.

    1996-01-01

    Radiochromic film is shown to be a useful surface-dose detector for radiotherapy x-ray beams. Central-axis percentage surface-dose results as measured by Gafchromic film for a 6 MVp x-ray beam produced by a Varian 2100C Linac at 100 cm SSD are 16%, 25%, 35%, 41% for 10, 20, 30 and 40 cm square field sizes, respectively. Using a simple, uniform light source and a CCD camera connected to an image analysis system, quantitative 3D surface doses are accurately attainable in real time as either numerical data, a black-and-white image or a colour-enhanced image. (Author)

  3. "Frango com frango é coisa de paulista”: erotismo, deslocamentos e homossexualidade entre Recife e São Paulo

    Directory of Open Access Journals (Sweden)

    Isadora Lins França

    Full Text Available Neste artigo, desenvolvo uma reflexão explorando possíveis articulações entre trânsitos, itinerários, homossexualidade masculina, desejo e marcadores sociais da diferença. Analiso a produção discursiva de sentidos de lugar relacionados ao Recife e a São Paulo a partir de pesquisa etnográfica com homens que se relacionam afetivo-sexualmente com outros homens nas duas cidades - e transitam entre elas - buscando compreender como nesse processo articulam-se convenções de gênero e sexualidade, noções de brasilidade e regionalidade e sistemas de classificação relacionados à homossexualidade. Ao mesmo tempo, tematizo tensões envolvendo relações em que a diferença - de classe social, cor/raça, geração, gênero, regionalidade e sexualidade - atua como motor do desejo entre esses homens, compondo roteiros que mesclam trocas afetivas, sexuais e materiais de variadas ordens, e em que certa dose de risco parece estar implicada.

  4. Relaciones de aprendizaje significativo entre dos paradigmas de programación a partir de dos lenguajes de programación

    Directory of Open Access Journals (Sweden)

    Omar Iván Trejos Buriticá

    2014-04-01

    Full Text Available Una de las dificultades que, con frecuencia, se presenta en los currículos de Ingeniería de Sistemas es el hecho de que se establecen pocas relaciones entre lo que los estudiantes han aprendido en una asignatura de programación y lo que van a aprender en otra. Este artículo plantea una propuesta para que se puedan establecer, desde la primera sesión, relaciones entre el paradigma de programación funcional (utilizando DrScheme como instancia tecnológica y el paradigma de programación estructurada (utilizando DevC++ en su arista estructurada como lenguaje de programación. Se plantean las experiencias recogidas al respecto de la aplicación de esta estrategia y, sobre los resultados se presentan algunas reflexiones que pueden enriquecer el desarrollo de la línea de programación en los programas de Ingeniería a partir de las relaciones que se pueden establecer tanto entre paradigmas de programación como entre los lenguajes de programación con miras a que el camino de aprendizaje de estos sea mucho más simple.

  5. Modeling for Dose Rate Calculation of the External Exposure to Gamma Emitters in Soil

    International Nuclear Information System (INIS)

    Allam, K. A.; El-Mongy, S. A.; El-Tahawy, M. S.; Mohsen, M. A.

    2004-01-01

    Based on the model proposed and developed in Ph.D thesis of the first author of this work, the dose rate conversion factors (absorbed dose rate in air per specific activity of soil in nGy.hr - 1 per Bq.kg - 1) are calculated 1 m above the ground for photon emitters of natural radionuclides uniformly distributed in the soil. This new and simple dose rate calculation software was used for calculation of the dose rate in air 1 m above the ground. Then the results were compared with those obtained by five different groups. Although the developed model is extremely simple, the obtained results of calculations, based on this model, show excellent agreement with those obtained by the above-mentioned models specially that one adopted by UNSCEAR. (authors)

  6. Pagos parciales a interés simple: una nota financiera

    Directory of Open Access Journals (Sweden)

    Daniel Villalobos Céspedes

    2011-12-01

    Full Text Available Este escrito pretende ser un aporte a las matemáticas financieras. En especial, plantea formular el concepto de pagos parciales simplificado mediante el uso del criterio de suma de dígitos. La fórmula propuesta permite estimar las distintas variables incógnitas entre las que componen el modelo aquí propuesto. La utilidad del modelo es tanto académica como práctica. Podría ser parte de un software que permita además, el cálculo de cancelación adelantada de un crédito de pago parcial a interés simple.

  7. Low-dose computed tomography image restoration using previous normal-dose scan

    International Nuclear Information System (INIS)

    Ma, Jianhua; Huang, Jing; Feng, Qianjin; Zhang, Hua; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2011-01-01

    Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use

  8. Dose Vocal: uma revisão integrativa da literatura

    Directory of Open Access Journals (Sweden)

    Joana Perpétuo Assad

    Full Text Available RESUMO O objetivo da pesquisa foi realizar uma revisão da literatura referente aos tipos de dose vocal e aos resultados destas medidas em diferentes situações comunicativas. Houve levantamento da literatura nacional e internacional, publicada nos idiomas Inglês, Espanhol ou Português, utilizando-se as bases de dados MEDLINE, LILACS, IBECS e ISI (Web of Science, dos últimos 21 anos, cujos artigos estavam disponíveis na íntegra. Quinze estudos contemplaram os critérios propostos. A maioria dos artigos estudou professores, visto que são mais vulneráveis para a ocorrência de disfonia. Os tipos de dose encontrados foram porcentagem de fonação, dose temporal, dose cíclica, dose de distância, dose de energia radiada e dose de energia dissipada. O aumento da dose vocal está associado ao uso excessivo e prolongado da voz na atividade docente, principalmente entre os professores da educação infantil e os de canto. As altas doses vocais correlacionam-se também à presença de disfonia, ao maior nível de ruído ambiental, à grande variação prosódica na fala e à autopercepção de fadiga vocal. Pacientes com disfonia comportamental (nódulos e pólipos apresentam maiores doses vocais que pacientes com outros quadros disfônicos. Fatores como repouso de voz e uso do amplificador vocal indicam a diminuição da dose da voz.

  9. A new definition for acoustic dose

    International Nuclear Information System (INIS)

    Duck, F A

    2011-01-01

    This paper discusses a recent proposal for definitions of acoustic dose and acoustic dose-rate. Acoustic dose is defined as the energy deposited by absorption of an acoustic wave per unit mass of the medium supporting the wave. Its time-derivative, acoustic dose-rate, Q m , in W kg -1 is central to the prediction of both rate of temperature rise and radiation force. These quantities have spatial and temporal dependency, depending on the local field parameters (acoustic pressure, particle velocity, intensity) and local material properties (absorption coefficient, α a , and mass density, ρ 0 ). Spatial and/or temporal averaging can be applied where appropriate. For plane-wave monochromatic conditions in a homogeneous medium, Q m =2α a I/ρ 0 , (I is the time-averaged intensity), a simple expression which may also incorporate frequency dependencies of energy deposition. Acoustic dose and acoustic does-rate are exact analogues for Specific Absorption and Specific Absorption Rate (SAR), quantities central to radiofrequency (RF) and microwave dosimetry. Acoustic dosimetry in the presence of tissue/gas interfaces remains a considerable challenge.

  10. Baixas doses de misoprostol vaginal (12,5 versus 25 mcg para indução do parto a termo Low-dose vaginal misoprostol (12.5 versus 25 µg for induction of labor at term

    Directory of Open Access Journals (Sweden)

    Francisco Airton Rangel Filho

    2007-12-01

    Full Text Available OBJETIVO: comparar a efetividade de baixas doses de misoprostol vaginal (12,5 versus 25 mcg para indução do trabalho de parto. MÉTODOS: ensaio clínico controlado, randomizado, duplo-cego, realizado entre maio de 2005 e abril de 2006. Foram incluídas 62 gestantes com gravidez a termo, membranas íntegras, que necessitaram de indução do parto. Foi administrado 25 mcg (32 ou 12,5 mcg de misoprostol (30, a cada quatro horas, até, no máximo, oito doses. Estudaram-se o tipo de parto, tempo entre o início da indução e o parto, complicações perinatais e efeitos maternos adversos. As variáveis de controle foram idades materna e gestacional, paridade e índice de Bishop. Os testes estatísticos utilizados foram cálculos de médias, desvios padrão e teste t de Student (variáveis numéricas contínuas, c² (variáveis categóricas e Mann-Whitney (variáveis discretas. RESULTADOS: não houve diferença significante entre o Grupo de 12,5 e 25 mcg em relação ao intervalo de tempo entre a primeira dose e o parto (1.524 minutos versus 1.212 minutos, p=0,3, na freqüência de partos vaginais (70 versus 71,8%, p=0,7, no escore de Apgar inferior a sete ao quinto minuto (3,3 versus 6,25%, p=0,5 e na freqüência de taquissistolia (3,3 versus 6,2%, p=0,5. A média da dose total administrada de misoprostol foi significativamente maior no Grupo de 25 mcg (40 versus 61,2 mcg, p=0,03. CONCLUSÕES: misoprostol vaginal na dose de 12,5 mcg foi eficiente, com efeitos colaterais semelhante, à dose de 25 mcg de misoprostol vaginal, para indução do parto a termo.PURPOSE: to compare the effectiveness of low doses of vaginal misoprostol (12.5 versus 25 µg for induction of labor. METHODS: a double-blind, randomized, controlled clinical trial was performed in Santa Casa de Misericórdia de Sobral, from May 2005 to April 2006. Sixty-two term pregnant women, with intact membranes and with indication for labor induction, were included. They randomly received 25

  11. Model of organ dose combination

    International Nuclear Information System (INIS)

    Valley, J.-F.; Lerch, P.

    1977-01-01

    The ICRP recommendations are based on the limitation of the dose to each organ. In the application and for a unique source the critical organ concept allows to limit the calculation and represents the irradiation status of an individuum. When several sources of radiation are involved the derivation of the dose contribution of each source to each organ is necessary. In order to represent the irradiation status a new parameter is to be defined. Propositions have been made by some authors, in particular by Jacobi introducing at this level biological parameters like the incidence rate of detriment and its severity. The new concept is certainly richer than a simple dose notion. However, in the actual situation of knowledge about radiation effects an intermediate parameter, using only physical concepts and the maximum permissible doses to the organs, seems more appropriate. The model, which is a generalization of the critical organ concept and shall be extended in the future to take the biological effects into account, will be presented [fr

  12. Extremity doses of medical staff involved in interventional radiology and cardiology: Correlations and annual doses (hands and legs)

    International Nuclear Information System (INIS)

    Krim, S.; Brodecki, M.; Carinou, E.; Donadille, L.; Jankowski, J.; Koukorava, C.; Dominiek, J.; Nikodemova, D.; Ruiz-Lopez, N.; Sans-Merce, M.; Struelens, L.; Vanhavere, F.

    2011-01-01

    An intensive measurement campaign was launched in different hospitals in Europe within work package 1 of the ORAMED project (Optimization of RAdiation protection for MEDical staff). Its main objective was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimize staff protection. The monitored procedures were divided in three main categories: cardiac, general angiography and endoscopic retrograde cholangio-pancreatography(ERCP) procedures. Using a common measurement protocol, information such as the protective equipment used (lead table curtain, transparent lead glass ceiling screen, patient shielding, whole body shielding or special cabin etc.) as well as Kerma Area Product (KAP) values and access of the catheter were recorded. This study was performed with a final database of more than 1300 procedures performed in 34 European hospitals. Its objectives were firstly to determine if the measured extremity doses could be correlated to the KAP values; secondly to check if the doses to the eyes could be linked to the doses to the hands (finger or wrist positions) and finally if the doses to the fingers could be estimated based on the doses to the wrists. General correlations were very difficult to find and their strength was mostly influenced by three main parameters: the X-ray tube configuration, the room collective radioprotective equipment and the access of the catheter. The KAP value can provide a simple mean to estimate the extremity doses of the operator given that it is assessed correctly for the operator when he is actually using the X-ray tube. Moreover, this study showed that the doses to the left finger are strongly correlated to the doses to the left wrist when no ceiling shield is used. It is also possible to estimate the doses to the eyes given the doses to the left finger or left wrist but the X-ray tube configuration and the access have to be considered. The annual

  13. Application of a simple phantom in assessing the effects of dose reduction on image quality in chest radiography

    International Nuclear Information System (INIS)

    Egbe, N.O.; Heaton, B.; Sharp, P.F.

    2010-01-01

    Purpose: Firstly, to evaluate a commercial chest phantom incorporating a quasi anthropomorphic insert by comparing exposure measurements on the phantom with those of actual patients and, secondly, to assess the value of the phantom for image quality and dose optimisation. Methods: In the first part of the study entrance surface doses (ESD), Beam transmission (BT), and optical density (OD) were obtained for 77 chest radiography patients and compared with measurements made from exposures of the phantom using the respective patient exposure factors from chest examination. Differences were assessed with a student t-test, while the Pearson's linear correlation coefficient was used to test for any linear relationship. The second part assessed the applicability of the phantom to image quality studies by investigating the effect, on the clarity and detectability of lung lesions made from gelatine, of reducing patient dose below current dose levels. Clarity of linear objects of different dimensions was also studied. Lesion detectability and clarity was assessed by four observers. The possibility of extending dose reduction below current dose levels (D ref ) was assessed from comparison of doses that produced statistically significant differences in image quality from D ref . Results: Results show that, with the exception of entrance doses and beam transmission through the diaphragm (P > 0.05), differences in OD and beam transmission between patients and phantom were statistically significant (P ref produced significant changes in both clarity and detectability. Conclusion: Within limits posed by the observed differences, the phantom can be applied to image quality studies in diagnostic radiology.

  14. Dose Response Model of Biological Reaction to Low Dose Rate Gamma Radiation

    International Nuclear Information System (INIS)

    Magae, J.; Furikawa, C.; Hoshi, Y.; Kawakami, Y.; Ogata, H.

    2004-01-01

    It is necessary to use reproducible and stable indicators to evaluate biological responses to long term irradiation at low dose-rate. They should be simple and quantitative enough to produce the results statistically accurate, because we have to analyze the subtle changes of biological responses around background level at low dose. For these purposes we chose micronucleus formation of U2OS, a human osteosarcoma cell line, as indicators of biological responses. Cells were exposed to gamma ray in irradiation rom bearing 50,000 Ci 60Co. After irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, and cytoplasm and nucleus were stained with DAPI and prospidium iodide, respectively. the number of binuclear cells bearing micronuclei was counted under a fluorescence microscope. Dose rate in the irradiation room was measured with PLD. Dose response of PLD is linear between 1 mGy to 10 Gy, and standard deviation of triplicate count was several percent of mean value. We fitted statistically dose response curves to the data, and they were plotted on the coordinate of linearly scale response and dose. The results followed to the straight line passing through the origin of the coordinate axes between 0.1-5 Gy, and dose and does rate effectiveness factor (DDREF) was less than 2 when cells were irradiated for 1-10 min. Difference of the percent binuclear cells bearing micronucleus between irradiated cells and control cells was not statistically significant at the dose above 0.1 Gy when 5,000 binuclear cells were analyzed. In contrast, dose response curves never followed LNT, when cells were irradiated for 7 to 124 days. Difference of the percent binuclear cells bearing micronucleus between irradiated cells and control cells was not statistically significant at the dose below 6 Gy, when cells were continuously irradiated for 124 days. These results suggest that dose response curve of biological reaction is remarkably affected by exposure

  15. An efficient dose-compensation method for proximity effect correction

    International Nuclear Information System (INIS)

    Wang Ying; Han Weihua; Yang Xiang; Zhang Yang; Yang Fuhua; Zhang Renping

    2010-01-01

    A novel simple dose-compensation method is developed for proximity effect correction in electron-beam lithography. The sizes of exposed patterns depend on dose factors while other exposure parameters (including accelerate voltage, resist thickness, exposing step size, substrate material, and so on) remain constant. This method is based on two reasonable assumptions in the evaluation of the compensated dose factor: one is that the relation between dose factors and circle-diameters is linear in the range under consideration; the other is that the compensated dose factor is only affected by the nearest neighbors for simplicity. Four-layer-hexagon photonic crystal structures were fabricated as test patterns to demonstrate this method. Compared to the uncorrected structures, the homogeneity of the corrected hole-size in photonic crystal structures was clearly improved. (semiconductor technology)

  16. Dose compensation of the total body irradiation therapy

    International Nuclear Information System (INIS)

    Lin, J.-P.; Chu, T.-C.; Liu, M.-T.

    2001-01-01

    The aim of the study is to improve dose uniformity in the body by the compensator-rice and to decrease the dose to the lung by the partial lung block. Rando phantom supine was set up to treat bilateral fields with a 15 MV linear accelerator at 415 cm treatment distance. The experimental procedure included three parts. The first part was the bilateral irradiation without rice compensator, and the second part was with rice compensator. In the third part, rice compensator and partial lung block were both used. The results of thermoluminescent dosimeters measurements indicated that without rice compensator the dose was non-uniform. Contrarily, the average dose homogeneity with rice compensator was measured within ±5%, except for the thorax region. Partial lung block can reduce the dose which the lung received. This is a simple method to improve the dose homogeneity and to reduce the lung dose received. The compensator-rice is cheap, and acrylic boxes are easy to obtain. Therefore, this technique is suitable for more studies

  17. A SIMPLE EXPERIMENTAL MODEL OF HEAT SHOCK RESPONSE IN RATS

    Directory of Open Access Journals (Sweden)

    Tufi Neder Meyer

    1998-10-01

    Full Text Available Objective: To obtain a simple model for the elicitation of the heat shock response in rats. Design: Laboratory study. Setting: University research laboratories. Sample: Seventy-nine adult male albino rats (weight range 200 g to 570 g. Procedures: Exposure to heat stress by heating animals in a warm bath for 5 min after their rectal temperatures reached 107.60 F (420 C. Liver and lung samples were collected for heat-shock protein 70 (HSP70 detection (Western analysis. Results: Western analysis was positive for HSP70 in the liver and in the lungs of heated animals. There was a temporal correlation between heating and HSP70 detection: it was strongest 1 day after heating and reduced afterwards. No heated animals died. Conclusion: These data show that heating rats in a warm (45o C bath, according to parameters set in this model, elicits efficiently the heat shock response.OBJETIVO: Obter um modelo simples para tentar esclarecer a resposta ao choque térmico em ratos. LOCAL: Laboratório de pesquisa da Universidade. MÉTODO: Amostra: 79 ratos albinos, adultos, entre 200g a 570g. Procedimentos: Exposição ao calor, em banho quente, por 5 minutos, após a temperatura retal chegar a 42 graus centigrados. Biópsias de fígado e pulmão foram obtidas para detectar a proteina 70 (HSP 70, pelo "Western blot". RESULTADOS: As análises foram positivas nos animais aquecidos, com uma correlação entre aquecimento e constatação da HSP 70. Foi mais elevada no primeiro dia e não houve óbitos nos animais aquecidos. CONCLUSÃO: Os ratos aquecidos a 45 graus centígrados respondem eficientemente ao choque térmico.

  18. Doing the math: A simple approach to topical timolol dosing for infantile hemangiomas.

    Science.gov (United States)

    Dalla Costa, Renata; Prindaville, Brea; Wiss, Karen

    2018-03-01

    Topical timolol maleate has recently gained popularity as a treatment for superficial infantile hemangiomas, but calculating a safe dose of timolol can be time consuming, which may limit the medication's use in fast-paced clinical environments. This report offers a simplified calculation of the maximum daily safe dosage as 1 drop of medication per kilogram of body weight. © 2018 Wiley Periodicals, Inc.

  19. A simple high-dose gentamicin regimen showed no side effects among neonates

    DEFF Research Database (Denmark)

    Blaabjerg, Anne Sofie; Kofoed, Poul-Erik; Dalegaard, Mette Correll

    2017-01-01

    INTRODUCTION: Treatment of infections in neonates with gentamicin is a balance between optimising bactericidal effect and minimising adverse effects. Previously, at the Neonatal Intensive Care Unit (NICU) at Kolding Hospital, Denmark, neonates suspected of having infections were treated daily...... and 2012 and treated with gentamicin were included retrospectively in the study. Neonates with trough serum (S)-gentamicin level ≥ 2.0 mg/l before the third dose were reviewed in detail. RESULTS: In total, S-gentamicin level was measured in 253 treated neonates of whom 7% displayed elevated trough values....... Neonates elevated S...

  20. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    Science.gov (United States)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F.; Long, Daniel J.; Bolch, Wesley E.; Liu, Bob; Xu, X. George

    2015-07-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  1. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    International Nuclear Information System (INIS)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F; Xu, X George; Long, Daniel J; Bolch, Wesley E; Liu, Bob

    2015-01-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations. (paper)

  2. SU-F-T-267: A Clarkson-Based Independent Dose Verification for the Helical Tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, H [Shonan Kamakura General Hospital, Kamakura, Kanagawa, (Japan); Juntendo University, Hongo, Tokyo (Japan); Hongo, H [Shonan Kamakura General Hospital, Kamakura, Kanagawa, (Japan); Tsukuba University, Tsukuba, Ibaraki (Japan); Kawai, D [Kanagawa Cancer Center, Yokohama, Kanagawa (Japan); Takahashi, R [Cancer Institute Hospital of Japanese Foundation for Cancer Research, Koto, Tokyo (Japan); Hashimoto, H [Shonan Fujisawa Tokushukai Hospital, Fujisawa, Kanagawa (Japan); Tachibana, H [National Cancer Center, Kashiwa, Chiba (Japan)

    2016-06-15

    Purpose: There have been few reports for independent dose verification for Tomotherapy. We evaluated the accuracy and the effectiveness of an independent dose verification system for the Tomotherapy. Methods: Simple MU Analysis (SMU, Triangle Product, Ishikawa, Japan) was used as the independent verification system and the system implemented a Clarkson-based dose calculation algorithm using CT image dataset. For dose calculation in the SMU, the Tomotherapy machine-specific dosimetric parameters (TMR, Scp, OAR and MLC transmission factor) were registered as the machine beam data. Dose calculation was performed after Tomotherapy sinogram from DICOM-RT plan information was converted to the information for MU and MLC location at more segmented control points. The performance of the SMU was assessed by a point dose measurement in non-IMRT and IMRT plans (simple target and mock prostate plans). Subsequently, 30 patients’ treatment plans for prostate were compared. Results: From the comparison, dose differences between the SMU and the measurement were within 3% for all cases in non-IMRT plans. In the IMRT plan for the simple target, the differences (Average±1SD) were −0.70±1.10% (SMU vs. TPS), −0.40±0.10% (measurement vs. TPS) and −1.20±1.00% (measurement vs. SMU), respectively. For the mock prostate, the differences were −0.40±0.60% (SMU vs. TPS), −0.50±0.90% (measurement vs. TPS) and −0.90±0.60% (measurement vs. SMU), respectively. For patients’ plans, the difference was −0.50±2.10% (SMU vs. TPS). Conclusion: A Clarkson-based independent dose verification for the Tomotherapy can be clinically available as a secondary check with the similar tolerance level of AAPM Task group 114. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

  3. The starting dose of levothyroxine in primary hypothyroidism treatment: a prospective, randomized, double-blind trial

    NARCIS (Netherlands)

    Roos, Annemieke; Linn-Rasker, Suzanne P.; van Domburg, Ron T.; Tijssen, Jan P.; Berghout, Arie

    2005-01-01

    BACKGROUND: The treatment of hypothyroidism with levothyroxine is effective and simple; however, recommendations for the starting dose vary considerably. To our knowledge, the levothyroxine starting dose has never been studied prospectively. METHODS: We conducted a prospective, randomized,

  4. Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I

    International Nuclear Information System (INIS)

    Vega-Carrillo, Hector Rene; Manzanares-Acuna, Eduardo; Hernandez-Davila, Victor Martin; Arcos-Pichardo, Areli; Barquero, Raquel; Iniguez, M. Pilar

    2006-01-01

    The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons' attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation

  5. Estimating effective doses to children from CT examinations

    International Nuclear Information System (INIS)

    Heron, J.C.L.

    2000-01-01

    Full text: Assessing doses to patients in diagnostic radiology is an integral part of implementing optimisation of radiation protection. Sources of normalised data are available for estimating doses to adults undergoing CT examinations, but for children this is not the case. This paper describes a simple method for estimating effective doses arising from paediatric CT examinations. First the effective dose to an adult is calculated, having anatomically matched the scanned regions of the child and the adult and also matched the irradiation conditions. A conversion factor is then applied to the adult effective dose, based on the region of the body being scanned - head, upper or lower trunk. This conversion factor is the child-to-adult ratio of the ratios of effective dose per entrance air kerma (in the absence of the patient) at the FAD. The values of these conversion factors were calculated by deriving effective dose per entrance air kerma at the FAD for new-born, 1, 5, 10, 15 and adult phantoms using four projections (AP, PA, left and right laterals) over a range of beam qualities and FADs.The program PCXMC was used for this purpose. Results to date suggest that the conversion factors to give effective doses for children undergoing CT examinations of the upper trunk are approximately 1.3, 1.2, 1.15, 1.1 and 1.05 for ages 0, 1, 5, 10 and 15 years respectively; CT of the lower trunk - 1.4, 1.3, 1.2, 1.2, 1.1; and CT of the head - 2.3, 2.0, 1.5, 1.3, 1.1. The dependence of these factors on beam quality (HVL from 4 to 10 mm Al) is less than 10%, with harder beams resulting in slightly smaller conversion factors. Dependence on FAD is also less than 10%. Major sources of uncertainties in the conversion factors include matching anatomical regions across the phantoms, and the presence of beam divergence in the z-direction when deriving the factors. The method described provides a simple means of estimating effective doses arising from paediatric CT examinations with

  6. DOSE-Analyzer. A computer program with graphical user interface to analyze absorbed dose inside a body of mouse and human upon external neutron exposure

    International Nuclear Information System (INIS)

    Satoh, Daiki; Takahashi, Fumiaki; Shigemori, Yuji; Sakamoto, Kensaku

    2010-06-01

    DOSE-Analyzer is a computer program to retrieve the dose information from a database and generate a graph through a graphical user interface (GUI). The database is constructed for absorbed dose, fluence, and energy distribution inside a body of mouse and human exposed upon external neutrons, which is calculated by our developed Monte-Carlo simulation method using voxel-based phantom and particle transport code PHITS. The input configurations of irradiation geometry, subject, and energy are set by GUI. The results are tabulated at particle types, i.e. electron, proton, deuteron, triton, and alpha particle, and target organs on a data sheet of Microsoft Office Excel TM . Simple analysis to compare the output values for two subjects is also performed on DOSE-Analyzer. This report is a user manual of DOSE-Analyzer. (author)

  7. CT-based dose calculations and in vivo dosimetry for lung cancer treatment

    International Nuclear Information System (INIS)

    Essers, M.; Lanson, J.H.; Leunens, G.; Schnabel, T.; Mijnheer, B.J.

    1995-01-01

    Reliable CT-based dose calculations and dosimetric quality control are essential for the introduction of new conformal techniques for the treatment of lung cancer. The first aim of this study was therefore to check the accuracy of dose calculations based on CT-densities, using a simple inhomogeneity correction model, for lung cancer patients irradiated with an AP-PA treatment technique. Second, the use of diodes for absolute exit dose measurements and an Electronic Portal Imaging Device (EPID) for relative transmission dose verification was investigated for 22 and 12 patients, respectively. The measured dose values were compared with calculations performed using our 3-dimensional treatment planning system, using CT-densities or assuming the patient to be water-equivalent. Using water-equivalent calculations, the actual exit dose value under lung was, on average, underestimated by 30%, with an overall spread of 10% (1 SD). Using inhomogeneity corrections, the exit dose was, on average, overestimated by 4%, with an overall spread of 6% (1 SD). Only 2% of the average deviation was due to the inhomogeneity correction model. An uncertainty in exit dose calculation of 2.5% (1 SD) could be explained by organ motion, resulting from the ventilatory or cardiac cycle. The most important reason for the large overall spread was, however, the uncertainty involved in performing point measurements: about 4% (1 SD). This difference resulted from the systematic and random deviation in patient set-up and therefore in diode position with respect to patient anatomy. Transmission and exit dose values agreed with an average difference of 1.1%. Transmission dose profiles also showed good agreement with calculated exit dose profiles. Our study shows that, for this treatment technique, the dose in the thorax region is quite accurately predicted using CT-based dose calculations, even if a simple inhomogeneity correction model is used. Point detectors such as diodes are not suitable for exit

  8. Design of movable fixed area γ dose rate monitor

    International Nuclear Information System (INIS)

    Li Dongyu; Cheng Wen; Li Jikai; Huang Hong; Shen Qiming; Zhang Qiang; Liu Zhengshan

    2005-10-01

    Movable fixed area γ dose rate monitor has not only the characteristics of fixed area γ dose rate monitor, but that of portable meter as well. Its main function is to monitor the areas where dose rate would change without orderliness to prevent unplanned radiation exposure accidents from happening. The design way of the monitor, the main indicators description, the working principle and the comprising of software and hardware are briefly introduced. The monitor has the characteristics of simple installation, easy maintenance, little power consumption, wide range, notability of visual and audible alarm and so on. Its design and technique have novelty and advancement. (authors)

  9. Review of time-dose effects in radiation therapy

    International Nuclear Information System (INIS)

    Peschel, R.E.; Fischer, J.J.

    1980-01-01

    A historical review of conventional fractionation offers little confidence that such treatment is optimal for all tumors. Thus manipulation of time-dose schedules may provide a relatively inexpensive yet potentially useful technique for improving therapeutic results in radiation therapy. Consideration of basic radiobiological principles and animal model data illustrates the complex and heterogeneous nature of normal tissue and tumor response to time-dose effects and supports the hypothesis that better time-dose prescriptions can be found in clinical practice. The number of possible time-dose prescriptions is very large, and a review of the clinical trials using nonconventional fractionation demonstrates that the sampled portion of the total three-dimensional space of time, fraction number, and dose has been very small. Only carefully designed clinical trials can establish the therapeutic advantage of a new treatment schedule, and methods for selecting the most promising schedules are discussed. The use of simple data reduction formulas for time-dose effects should be discarded since they ignore the very complexity and heterogeneity of tissues and tumors which may form the basis of improved clinical results

  10. Tabagismo entre trabalhadores de empresa bancária Cigarette smoking among workers of a Bank

    Directory of Open Access Journals (Sweden)

    Rosane H. Griep

    1998-12-01

    Full Text Available OBJETIVO: Descrever a prevalência de tabagismo e sua associação com outros fatores de risco para doenças crônicas entre funcionários dos centros de processamentos de serviços e comunicações de uma empresa bancária. MÉTODO: Estudo seccional de amostra aleatória simples de 647 funcionários, através de questionário auto-respondido no ambiente de trabalho. RESULTADOS: A prevalência de tabagismo foi de 29,5% (Intervalo de Confiança (IC 95%: 27,5% a 31,5%, sendo 31,1% (IC 95%: 26,2% a 35,8% entre homens e 27,8% (IC 95%: 22,6% a 32,9% entre mulheres. O início do hábito ocorreu, em média, aos 17,6 anos entre os homens e 19,4 anos entre as mulheres. Observou-se alta prevalência de grandes fumantes entre homens e mulheres (53% e 42% respectivamente fumavam mais de 20 cigarros por dia. A freqüência de tabagismo foi maior nos mais velhos, nos divorciados separados e viúvos, nos hipertensos, naqueles que consumiam mais bebidas alcoólicas, e nos que não praticavam exercícios físicos. Comparados aos não-fumantes, os ex-fumantes eram mais velhos, consumiam mais bebidas alcoólicas e apresentavam maior freqüência de sobrepeso. CONCLUSÃO: A freqüência de tabagismo e de outros fatores de risco para as doenças crônicas, nesta categoria de trabalhadores, aponta para a necessidade de repensar estratégias das ações de saúde atualmente desenvolvidas. Oportunidades de intervenções preventivas mais eficazes e de menor custo podem estar sendo perdidas.OBJECTIVE: To describe the prevalence of cigarette smoking and its association with other risk factors for chronic diseases among active workers of communication and data processing centers of a Bank. METHODS: Cross-sectional study in a simple random sample of 647 active workers of the bank. The data were collected in the work environment, through self-administered questionnaires. RESULTS: The prevalence of cigarette smoking was 29.5% (95% Confidence Interval (CI: 27.5%-31.5%, 31

  11. Evaluation of the Basedow disease treatment by a iodine 131 fixed dose; Evaluation du traitement de la maladie de Basedow par une dose fixe d'iode 131

    Energy Technology Data Exchange (ETDEWEB)

    El Ajmi, W.; Slim, I; Rmadi, S.; Yeddes, I.; Krimi, S.; Ltaief, B.; Mhiri, A.; Ben Slimene, M.F. [Service de medecine nucleaire, institut Salah Azeiz, Tunis, (Tunisia)

    2009-05-15

    The treatment of the basedow disease by iodine 131 is more and more used. however, the doses used stay variable. In order to reduce the treatment failure, we chose a protocol with strong fix doses of iodine 131. We give our preliminary results for 63 patients. The treatment by strong fix dose of iodine 131 is simple, safe and efficient for the control of hyperthyroidism in the Basedow disease. This protocol has for advantage to be simpler comparatively to these ones using adjusted doses according the weight of the thyroid and its fixation rate. (N.C.)

  12. Correlações entre a maturidade da fibra e outros caracteres econômicos do algodoeiro Simple correlations between fiber maturity and economic characteristics in cotton

    Directory of Open Access Journals (Sweden)

    Nélson Paulieri Sabino

    1976-07-01

    Full Text Available As características da fibra - comprimento, uniformidade, índice Micronaire (finura, resistência Pressley -, a resistência do fio, assim como a porcentagem de fibra, peso de um capulho, peso de 100 sementes e a produção, foram correlacionados com a maturidade da fibra, determinada pelo fibrógrafo digital. Para tanto foram utilizados os dados de 12 ensaios regionais de variedades instalados no ano agrícola de 1970/71, e de 13 ensaios instalados em 1971/72, em diferentes locais do Estado de São Paulo. Esses ensaios, em quadrado latino 6x6, forneceram 72 pares de valores no primeiro ano e 78 pares no segundo, para os cálculos dos coeficientes de correlação. Estes foram computados por ano e por variedade. Valores médios foram estimados através da transformação Z de Fisher. Houve variações sensíveis no valor dos coeficientes entre anos dentro de variedades e entre variedades dentro de ano. As estimativas médias foram significativas, com exceção da resistência da fibra, da resistência do fio e da porcentagem de fibra. Houve falta de homogeneidade nos casos do índice Micronaire e da uniformidade de comprimento. No ano de 1971/72, de condições piores para o algodoeiro, os coeficientes de correlação alcançaram valores mais altos.Simple correlations between maturity indices determined by the digital fibrograph and the characteristics of fiber length, uniformity, Micronaire, Pressley (1/8 gauge, yarn strength, mean boll weight, mean weight of 100 seeds, percentage of fiber, and yield were studied. Data of 12 experiments of regional variety tests planted in 1970/71 and of 13 experiments planted in 1971/72 in different regions of the State of São Paulo were used. These experiments delined in 6x6 latin squares yielded 72 pairs of data in the first year and 78 in the second year. Correlation coefficients were computed by variety within years and mean estimates obtained through Fisher's Z transformation. Large variations of the

  13. A model for predicting skin dose received by patients from an x-ray ...

    African Journals Online (AJOL)

    Patient dosimetry has raised concern on quality assurance in hospitals. Several organisations and research groups have been advocating ways of minimising radiation dose received by patients in hospitals. In this paper we have shown that it is possible to obtain in a simple way a reasonable estimate of skin dose received ...

  14. Evaluation of dose to skin surface contamination in the factory Juzbado of fuel elements

    International Nuclear Information System (INIS)

    Ortiz Trujillo, D.; Agustin Perez Fonseca, A.; Alejandro Fuentes, A.

    2013-01-01

    The aim of this work is previously set a simple calculation methodology applicable to the boundary conditions surrounding the environment where skin contamination may have occurred so that you can evaluate in a simple and fast way the dose that the worker is receiving while enduring such pollution. (Author)

  15. Interesse e conhecimento em cirurgia refrativa entre estudantes de medicina

    Directory of Open Access Journals (Sweden)

    Kara José Flávio Cotait

    2002-01-01

    Full Text Available Objetivo: Realizou-se um estudo em estudantes da Faculdade de Medicina do ABC a fim de analisar e relacionar a freqüência de usuários de correção óptica, o tipo de vícios de refração, o número de pessoas submetidas à cirurgia refrativa e o conhecimento e interesse por essa operação. Métodos: realizou-se um levantamento entre estudantes de medicina da Faculdade de Medicina do ABC, no período de 19 a 21 de junho de 2000. Foi utilizado um questionário auto-aplicável como instrumento de coleta de dados. Resultados: foi relatado que 62,7% dos estudantes usavam correção óptica, sendo que 53,3% desses apresentavam, como erro de refração, miopia simples ou associada ao astigmatismo. 92,8% do total dos entrevistados já tinham ouvido falar em cirurgia refrativa, contendo apenas 34,2% conhecedores dessa técnica cirúrgica e 17,6% conhecedores dos riscos e complicações pós-operatórios. Entre os 200 estudantes amétropes, 50,5% gostariam de ser submetidos à operação, sendo que 69,0% deles esperavam, através da cirurgia, a cura definitiva. Foi coletado, também, que 51,7% dos entrevistados tiveram a última consulta oftalmológica há menos de 1 ano; 32,0% entre 1 e 3 anos e 15,7% há mais de três anos. Apenas 5 estudantes já tinham sido submetidos à cirurgia refrativa. Conclusão: A maioria dos estudantes de Medicina (62,7% é portador de vício de refração corrigido, sendo os mais freqüentes a miopia simples e a miopia associada a astigmatismo. Há pouco conhecimento e falsa expectativa em relação à cirurgia, sendo que apenas 34,2% entrevistados conhecem o procedimento cirúrgico, 17,6% sabem dos riscos e das complicações e 69,0% esperam cura total. Diante das condições desse estudo, foi constatado que apesar de muitos se interessarem pela cirurgia refrativa, poucos se submeteram a ela, devido, principalmente, em ordem decrescente, a: contra-indicação médica, falta de oportunidade, falta de conhecimento e

  16. Fast motion-including dose error reconstruction for VMAT with and without MLC tracking

    DEFF Research Database (Denmark)

    Ravkilde, Thomas; Keall, Paul J.; Grau, Cai

    2014-01-01

    of the algorithm for reconstruction of dose and motion-induced dose errors throughout the tracking and non-tracking beam deliveries was quantified. Doses were reconstructed with a mean dose difference relative to the measurements of -0.5% (5.5% standard deviation) for cumulative dose. More importantly, the root...... validate a simple model for fast motion-including dose error reconstruction applicable to intrafractional QA of MLC tracking treatments of moving targets. MLC tracking experiments were performed on a standard linear accelerator with prototype MLC tracking software guided by an electromagnetic transponder......-mean-square deviation between reconstructed and measured motion-induced 3%/3 mm γ failure rates (dose error) was 2.6%. The mean computation time for each calculation of dose and dose error was 295 ms. The motion-including dose reconstruction allows accurate temporal and spatial pinpointing of errors in absorbed dose...

  17. Dosimetric characterization of an electronic portal imaging device (EPID) and development of a portal dosimetry simple model; Caracterizacion dosimetrica de un dispositivo electronico de imagen portal (EPID) y desarrollo de un modelo simple de dosimetria portal

    Energy Technology Data Exchange (ETDEWEB)

    Ripol ValentIn, O.; GarcIa Romero, A.; Hernandez Vitoria, A.; Jimenez Albericio, J.; Cortes Rodicio, J.; Millan Cebrian, E.; Ruiz Manzano, P.; Canellas Anoz, M.

    2010-07-01

    The use of the Electronic Portal Imaging Devices (EPID) for the quality control of linear accelerators of electrons is increasingly extended in practice. In this work the dosimetric characteristics of an EPID OptiVue{sup TM}1000 ST were studied and a friendly and simple method for the absorbed dose calibration was suggested. This method is based on a simple mathematical model, including: an absorbed dose transformation coefficient and image lag and field shape corrections. Software tools were developed in order to process the information and the results were validated by comparing them with the measured data with ionization chambers. The studied device showed suitable characteristics for its use for EPID dosimetry and the calculated results fitted satisfactorily with the dose planes obtained with the ionization chambers. Keeping in mind the model limitations, we concluded that it is possible to start the use of the EPID for the accelerator quality control and improvements for the current model should be studied, as well as other suitable applications: e.g. the Intensity Modulated Radiation Therapy (IMRT) treatment verification procedures. (Author).

  18. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method

    International Nuclear Information System (INIS)

    Thomas, Karen E.; Wang, Bo

    2008-01-01

    There is a need for an easily accessible method for effective dose estimation in pediatric CT. To estimate effective doses for a variety of pediatric neurological and body CT examinations in five age groups using recently published age- and region-specific dose length product (DLP) to effective dose conversion coefficients. A retrospective review was performed of 1,431 consecutive CT scans over a 12-week period using age- and weight-adjusted CT protocols. Age- and region-specific DLP to effective dose conversion coefficients were applied to console-displayed DLP data. Effective dose estimates for single-phase head CT scans in neonatal, and 1-, 5-, 10- and 15-year-old age groups were 4.2, 3.6, 2.4, 2.0 and 1.4 mSv, respectively. For abdomen/pelvis CT scans the corresponding effective doses were 13.1, 11.1, 8.4, 8.9 and 5.9 mSv. The range of pediatric CT effective doses is wide, from ultralow dose protocols (<1 mSv) to extended-coverage body examinations (10-15 mSv). Age- and region-specific pediatric DLP to effective dose conversion coefficients provide an accessible and user-friendly method for estimating pediatric CT effective doses that is available to radiologists working without medical physics support. (orig.)

  19. Monte Carlo estimation of the absorbed dose in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woo; Youn, Han Bean; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of)

    2016-05-15

    The purpose of this study is to devise an algorithm calculating absorbed dose distributions of patients based on Monte Carlo (MC) methods, and which includes the dose estimations due to primary and secondary (scattered) x-ray photons. Assessment of patient dose in computed tomography (CT) at the population level has become a subject of public attention and concern, and ultimate CT quality assurance and dose optimization have the goal of reducing radiation-induced cancer risks in the examined population. However, the conventional CT dose index (CTDI) concept is not a surrogate of risk but it has rather been designed to measure an average central dose. In addition, the CTDI or the dose-length product has showed troubles for helical CT with a wider beam collimation. Simple algorithms to estimate a patient specific CT dose based on the MCNP output data have been introduced. For numerical chest and head phantoms, the spatial dose distributions were calculated. The results were reasonable. The estimated dose distribution map can be readily converted into the effective dose. The important list for further studies includes the validation of the models with the experimental measurements and the acceleration of algorithms.

  20. A simple method to calculate the influence of dose inhomogeneity and fractionation in normal tissue complication probability evaluation

    International Nuclear Information System (INIS)

    Begnozzi, L.; Gentile, F.P.; Di Nallo, A.M.; Chiatti, L.; Zicari, C.; Consorti, R.; Benassi, M.

    1994-01-01

    Since volumetric dose distributions are available with 3-dimensional radiotherapy treatment planning they can be used in statistical evaluation of response to radiation. This report presents a method to calculate the influence of dose inhomogeneity and fractionation in normal tissue complication probability evaluation. The mathematical expression for the calculation of normal tissue complication probability has been derived combining the Lyman model with the histogram reduction method of Kutcher et al. and using the normalized total dose (NTD) instead of the total dose. The fitting of published tolerance data, in case of homogeneous or partial brain irradiation, has been considered. For the same total or partial volume homogeneous irradiation of the brain, curves of normal tissue complication probability have been calculated with fraction size of 1.5 Gy and of 3 Gy instead of 2 Gy, to show the influence of fraction size. The influence of dose distribution inhomogeneity and α/β value has also been simulated: Considering α/β=1.6 Gy or α/β=4.1 Gy for kidney clinical nephritis, the calculated curves of normal tissue complication probability are shown. Combining NTD calculations and histogram reduction techniques, normal tissue complication probability can be estimated taking into account the most relevant contributing factors, including the volume effect. (orig.) [de

  1. Correct statistical evaluation for total dose in rural settlement

    International Nuclear Information System (INIS)

    Vlasova, N.G.; Skryabin, A.M.

    2001-01-01

    Statistical evaluation of dose reduced to the determination of an average value and its error. If an average value of a total dose in general can be determined by simple summarizing of the averages of its external and internal components, the evaluation of an error can be received only from its distribution. Herewith, considering that both components of the dose are interdependent, to summarize their distributions, as a last ones of a random independent variables, is incorrect. It follows that an evaluation of the parameters of the total dose distribution, including an error, in general, cannot be received empirically, particularly, at the lack or absence of the data on one of the components of the last one, that constantly is happens in practice. If the evaluation of an average for total dose was defined somehow, as the best, as an average of a distribution of the values of individual total doses, as summarizing the individual external and internal doses by the random type, that an error of evaluation had not been produced. The methodical approach to evaluation of the total dose distribution at the lack of dosimetric information was designed. The essence of it is original way of an interpolation of an external dose distribution, using data on an internal dose

  2. Dogs-Assisted therapy in pediatric patients with balance pathology and intellectual difficulties : simple blind clinical trial

    OpenAIRE

    Fernández Otero, Melanie

    2016-01-01

    RESUMEN: Diseño: Se trata de un ensayo clínico cuasi experimental, con grupo control y simple ciego. Introducción: La Parálisis Cerebral es la primera causa de discapacidad infantil, esta patología afecta a diferentes capacidades motrices, como al equilibrio, y necesita de tratamiento fisioterápico entre otros. Dicha terapia puede complementarse con intervenciones como la Terapia Asistida con Animales. Objetivos: Evidenciar mejoría en la motricidad gruesa, especialmente en el equilibr...

  3. Estimation of dose from chromosome aberration rate

    International Nuclear Information System (INIS)

    Li Deping

    1990-01-01

    The methods and skills of evaluating dose from correctly scored shromsome aberration rate are presented, and supplemented with corresponding BASIC computer code. The possibility and preventive measures of excessive probability of missing score of the aberrations in some of the current routine score methods are discussed. The use of dose-effect relationship with exposure time correction factor G in evaluating doses and their confidence intervals, dose estimation in mixed n-γ exposure, and identification of high by nonuniform acute exposure to low LET radiation and its dose estimation are discussed in more detail. The difference of estimated dose due to whether the interaction between subleisoms produced by n and γ have been taken into account is examined. In fitting the standard dose-aberration rate curve, proper weighing of experiment points and comparison with commonly accepted values are emphasised, and the coefficient of variation σ y √y of the aberration rate y as a function of dose and exposure time is given. In appendix I and II, the dose-aberration rate formula is derived from dual action theory, and the time variation of subleisom is illustrated and in appendix III, the estimation of dose from scores of two different types of aberrations (of other related score) is illustrated. Two computer codes are given in appendix IV, one is a simple code, the other a complete code, including the fitting of standard curve. the skills of using compressed data storage, and the production of simulated 'data ' for testing the curve fitting procedure are also given

  4. Comparação entre mutagênicos químico e físico em populações de aveia

    Directory of Open Access Journals (Sweden)

    Coimbra Jefferson Luís Meirelles

    2005-01-01

    Full Text Available Comparou-se a campo a variabilidade genética em populações de aveia hexaplóide tratadas com agentes mutagênicos físico e químico, através do caráter ciclo vegetativo de plantas. Foram realizados experimentos em duas safras agrícolas em Pelotas, RS, em 1997/98 e 1998/99. As sementes foram irradiadas no Centro Regional de Oncologia da Faculdade de Medicina da UFPel, com uma taxa de dose de 0,25Gy min-1. As doses totais absorvidas para o mutagênico físico foram 100, 200 e 400Gy e, para o mutagênico químico 0,5, 1,5 e 3,0% por tratamento de 1200 sementes aproximadamente, em cada genótipo fixo de aveia avaliado. Foi obtida diferença na eficiência entre os agentes mutagênicos testados. O agente mutagênico físico foi sempre superior em relação ao agente mutagênico químico, independente da geração segregante avaliada, proporcionando assim um incremento maior no número de classes fenotípicas, tanto para redução quanto para o aumento do número de dias entre a emergência e o florescimento. Os genótipos mostraram sensibilidade diferenciada em relação à dose dos agentes mutagênicos avaliados, indicando que a eficiência dos tratamentos em alterar a variabilidade genética para precocidade e aumento do ciclo vegetativo foi variável. De modo geral, os dados indicaram decréscimo do caráter ciclo vegetativo com o acréscimo da dose dos agentes mutagênicos testados. O estudo das populações UPF-16 nas doses 100 e 200 gray submetidas ao tratamento com o agente mutagênico físico apontaram o maior grau de divergência genética e de dominância para o caráter ciclo vegetativo de plantas.

  5. Multiple cost criteria for occupational dose reduction

    International Nuclear Information System (INIS)

    James, J.Z.

    1983-01-01

    This paper describes a simple, feasible procedure for deciding if a proposed dose reduction measure is justified under ALARA, based on engineering economic principles of project feasibility analysis. Particular attention is given to the fixing of cost criteria: the importance of melding disparate objectives into a single parameter, and the distinction between a cost criterion and a cost consideration. (author)

  6. A simple device to protect against osteoradionecrosis induced by interstitial irradiation

    International Nuclear Information System (INIS)

    Levendag, P.C.; Visch, L.L.; Driver, N.

    1990-01-01

    The incidence of osteoradionecrosis has declined since the introduction of preventive oral hygiene programs and meticulous dental evaluations before and after irradiation. Nevertheless, radiation dose per se still remains an important factor in osteoradionecrosis. Interstitial radiation has received much attention in the past decade since the use of flexible afterloading systems. It has become common practice in large oncology centers to implant radiation carriers in bulky tumor in the oral cavity and/or oropharynx. For interstitial radiation, with or without external radiation, minimal tumor doses are often cited to be more than 70 Gy. Unfortunately, if the mandible receives more than 70 Gy, it is at risk for the development of osteoradionecrosis. Therefore a simple protective lead device has been designed for routine use in brachytherapy in oral cavity tumors to reduce the dose to the mandible. This device will diminish the potential risk of osteoradionecrosis development

  7. Simple machines

    CERN Document Server

    Graybill, George

    2007-01-01

    Just how simple are simple machines? With our ready-to-use resource, they are simple to teach and easy to learn! Chocked full of information and activities, we begin with a look at force, motion and work, and examples of simple machines in daily life are given. With this background, we move on to different kinds of simple machines including: Levers, Inclined Planes, Wedges, Screws, Pulleys, and Wheels and Axles. An exploration of some compound machines follows, such as the can opener. Our resource is a real time-saver as all the reading passages, student activities are provided. Presented in s

  8. Fluence-convolution broad-beam (FCBB) dose calculation

    Energy Technology Data Exchange (ETDEWEB)

    Lu Weiguo; Chen Mingli, E-mail: wlu@tomotherapy.co [TomoTherapy Inc., 1240 Deming Way, Madison, WI 53717 (United States)

    2010-12-07

    IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N{sup 3}) both spatially and temporally. This simple algorithm is orders of magnitude faster than the CCCS method. Without pre-calculation of beamlets, its implementation is also orders of magnitude smaller than the conventional voxel-based beamlet-superposition (VBS) approach. We compared the presented algorithm with the CCCS method using simulated and clinical cases. The agreement was generally within 3% for a homogeneous phantom and 5% for heterogeneous and clinical cases. Combined with the 'adaptive full dose correction', the algorithm is well suitable for calculating the iteration dose during IMRT optimization.

  9. Real time source term and dose assessment

    International Nuclear Information System (INIS)

    Breznik, B.; Kovac, A.; Mlakar, P.

    2001-01-01

    The Dose Projection Programme is a tool for decision making in case of nuclear emergency. The essential input data for quick emergency evaluation in the case of hypothetical pressurised water reactor accident are following: source term, core damage assessment, fission product radioactivity, release source term and critical exposure pathways for an early phase of the release. A reduced number of radio-nuclides and simplified calculations can be used in dose calculation algorithm. Simple expert system personal computer programme has been developed for the Krsko Nuclear Power Plant for dose projection within the radius of few kilometers from the pressurised water reactor in early phase of an accident. The input data are instantaneous data of core activity, core damage indicators, release fractions, reduction factor of the release pathways, spray operation, release timing, and dispersion coefficient. Main dose projection steps are: accurate in-core radioactivity determination using reactor power input; core damage and in-containment source term assessment based on quick indications of instrumentation or on activity analysis data; user defines release pathway for typical PWR accident scenarius; dose calculation is performed only for exposure pathway critical for decision about evacuation or sheltering in early phase of an accident.(author)

  10. Um método simples para o projeto ótimo de gráficos de X A simple method for optimal X-chart design

    Directory of Open Access Journals (Sweden)

    Eugenio K. Epprecht

    1998-12-01

    Full Text Available É desenvolvido um método simples e eficiente para a seleção de parâmetros (tamanho de amostra, intervalo de tempo entre amostras, e largura dos limites de controle para gráficos de para controle estatístico de processos, que fornece soluções ótimas em termos da relação entre a rapidez de detecção e os recursos alocados à inspeção. O método é superior a procedimentos baseados em propriedades estatísticas do gráfico (tais como o ARL e à adoção de valores empíricos gerais, e não apresenta as dificuldades de implementação dos métodos econômicos (economic design: não requer dados difíceis de obter ou estimar nem programas de computador para solução. Os resultados obtidos diferem de alguns resultados bem difundidos na literatura; mostra-se que os últimos são subótimos, por serem baseados em modelos que desconsideram aspectos importantes do problema. Uma contribuição adicional do método é o tratamento explícito e detalhado de restrições opcionais ao tamanho de amostra e/ou ao intervalo de tempo entre amostras. A simplicidade do método o torna viável para implementação em qualquer ambiente, e também apropriado para a sala de aula.A simple but efficient method has been developed for the design of -charts. The solutions provided are optimal in terms of the ratio between the number of items inspected per unit time and the detection speed (defined as the inverse of the average time to signal a shift in the mean. The method is superior to design procedures based exclusively on statistical properties of the chart (such as the ARL, and does not have the implementation drawbacks of economical design models. The results obtained differ from some results widely reported in the literature, which are shown to be sub-optimal as a consequence of their underlying model not considering some important aspects of the problem. An additional contribution of the method is the explicit treatment of optional constraints on the

  11. Study on the evaluation method of radiation dose rate around spent fuel shipping casks

    International Nuclear Information System (INIS)

    Yamakoshi, Hisao

    1986-01-01

    This study aims at developing a simple calculation method which can evaluate radiation dose rate around casks with high accuracy in a short time. The method is based on a concept of the radiation shielding characteristics of cask walls. The concept was introduced to replace for ordinary radiation shielding calculation which requires a long calculation time and a large memory capacity of a computer in the matrix calculation. For the purpose of verifying the accuracy and reliability of the new method, it was applied to the analysis of the dose rate distribution around actual casks, which had been measured. The results of the analysis revealed that the newly proposed method was excellent for the forecast of radiation dose rate distribution around casks in view of the accuracy and calculation time. The short calculation time and high accuracy by the proposed method were attained by dividing the whole procedure of ordinary fine radiation shielding calculation into the calculation of radiation dose rate on a cask surface by the matrix expression of the characteristic function and the calculation of dose rate distribution using the simple analytical expression of dose rate distribution around casks. The effect of the heterogeneous array of spent fuel in different burnup state on dose rate distribution around casks was evaluated by this method. (Kako, I.)

  12. Approach to 3D dose verification by utilizing autoactivation

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Yasunori, E-mail: yasunori.nkjm@gmail.com [Tokyo Institute of Technology, Yokohama-shi (Japan); Kohno, Toshiyuki [Tokyo Institute of Technology, Yokohama-shi (Japan); Inaniwa, Taku; Sato, Shinji; Yoshida, Eiji; Yamaya, Taiga [National Institute of Radiological Sciences, Chiba-shi (Japan); Tsuruta, Yuki [Tokyo Institute of Technology, Yokohama-shi (Japan); Sihver, Lembit [Chalmers University of Technology, Gothenburg (Sweden)

    2011-08-21

    To evaluate the deposited dose distribution in a target, we have proposed to utilize the annihilation gamma-rays emitted from the positron emitters distributed in the target irradiated with stable heavy-ion beams. Verification of the one dimensional (1-D) dose distributions along and perpendicular to a beam axis was achieved through our previous works. The purpose of this work is to verify 3-D dose distributions. As the first attempt uniform PMMA targets were irradiated in simple rectangular parallelepiped shapes, and the annihilation gamma-rays were detected with a PET scanner. By comparing the detected annihilation gamma-ray distributions with the calculated ones the dose distributions were estimated. As a result the estimated positions of the distal edges of the dose distributions were in agreement with the measured ones within 1 mm. However, the estimated positions of the proximal edges were different from the measured ones by 5-9 mm depending on the thickness of the irradiation filed.

  13. Dose Profiles in ECAL Crystals for Various Irradiation Conditions

    CERN Document Server

    Huhtinen, Mika

    1998-01-01

    Simulated dose profiles in various irradiation and beam test conditions are compared to the expected dose profiles in the ECAL crystals at LHC. Simple front or side irradiations with photons give too steep or too flat dose profiles, respectively. Thus, if dose maxima are fitted to agree, front irradiation underestimate the average dose whereas side irradiations tend to overestimate. Different profiles are difficult to compare reliably, but it seems likely that in both cases the discrepancy is about a factor of 2-3 but in different directions. For most purposes this is likely to be good enough, but should be taken into account in the interpretation of the test results. It is shown that using a customized lead mask between the source and the crystal can significantly improve the agreement between 60 Co side irradiations and the LHC predictions. A 400 MeV/c pion beam incident on a crystal matrix can also reproduce rather well the profiles expected in the barrel ECAL.

  14. Variabilidade do risco do tempo de permanência ajustado para lactentes de muito baixo peso ao nascer entre centros da Neocosur South American Network

    Directory of Open Access Journals (Sweden)

    Guillermo Marshall

    2012-12-01

    Full Text Available OBJETIVOS: Desenvolver um modelo de predição para o tempo de permanência hospitalar (TPH em lactentes de muito baixo peso ao nascer (MBPN e comparar esse resultado entre 20 centros de uma rede neonatal, visto que o TPH é utilizado como uma medida da qualidade da assistência em lactentes de MBPN. MÉTODOS: Utilizamos dados coletados prospectivamente de 7.599 lactentes com peso ao nascer entre 500 e 1.500 g no período entre os anos de 2001 a 2008. O modelo de regressão de Cox foi empregado para desenvolver dois modelos de predição: um modelo prévio com dados do nascimento e outro posterior, que acrescenta morbidades relevantes dos primeiros 30 dias de vida. RESULTADOS: A mediana do TPH estimado e ajustado a partir do nascimento foi de 59 dias; 28 dias depois do tempo de sobrevida de 30 dias. Houve uma alta correlação entre os modelos (r = 0,92. O TPH esperado e o TPH observado variaram bastante entre os centros, mesmo depois de correção para as morbidades relevantes após 30 dias. O TPH mediano (variação: 45-70 dias e a idade concepcional na alta hospitalar (variação: 36,4-39,9 semanas refletem uma variabilidade alta entre centros. CONCLUSÃO: Um modelo simples, com fatores apresentados no nascimento, pode predizer o TPH de um lactente de MBPN em uma rede neonatal. Observou-se uma variabilidade nos TPHs considerável entre unidades de terapia intensiva neonatal. Especulamos que os resultados sejam provenientes das diferenças entre as práticas dos centros.

  15. Determinantes de la precarización laboral en Argentina entre 2003-2013: entre los cambios y las continuidades

    Directory of Open Access Journals (Sweden)

    Marcelo Delfini

    2016-03-01

    Full Text Available El crecimiento económico experimentado por Argentina desde 2003 ha tenido su correlato en la mejora de los indicadores laborales. No obstante, la precarización laboral se ha mantenido, luego de una baja importante hasta el año 2007, en valores muy elevados. Partiendo de la idea central que la precarización constituye para el capital, una reducción de costos, el objetivo de este artículo es dar cuenta de los determinantes de la informalidad entre los trabajadores asalariados, estableciendo continuidades y cambios entre los años 2003 y 2013. Para ello utilizamos una metodología cuantitativa con fuentes secundarias de información, a partir de las cuales realizamos dos tipo de análisis, el primero de carácter descriptivo a partir del cual se busca dar cuenta de las características del mercado de trabajo argentino entre 1990 y 2013 y el segundo se realiza por medio de una regresión logística binomial, que permite acercarnos a los determinantes de la precarización de las condiciones de trabajo. En este sentido, se pudo observar que entre los años 2003 y 2013, se consolidó una precarización laboral, cuyos determinantes no lograron modificarse sustancialmente entre los años de referencia.

  16. Methods for calculating population dose from atmospheric dispersion of radioactivity

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, B L; Jow, H N; Lee, I S [Pittsburgh Univ., PA (USA)

    1978-06-01

    Curves are computed from which population dose (man-rem) due to dispersal of radioactivity from a point source can be calculated in the gaussian plume model by simple multiplication, and methods of using them and their limitations are considered. Illustrative examples are presented.

  17. Dosing algorithm to target a predefined AUC in patients with primary central nervous system lymphoma receiving high dose methotrexate.

    Science.gov (United States)

    Joerger, Markus; Ferreri, Andrés J M; Krähenbühl, Stephan; Schellens, Jan H M; Cerny, Thomas; Zucca, Emanuele; Huitema, Alwin D R

    2012-02-01

    There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h. A population covariate model from a pooled dataset of 131 patients receiving HDMTX was used to simulate concentration-time curves of 10,000 patients and test the efficacy of a dosing algorithm based on 24 h MTX plasma concentrations to target the prespecified AUC(MTX) . These data simulations included interindividual, interoccasion and residual unidentified variability. Patients received a total of four simulated cycles of HDMTX and adjusted MTX dosages were given for cycles two to four. The dosing algorithm proposes MTX dose adaptations ranging from +75% in patients with MTX C(24) 12 µmol l(-1). The proposed dosing algorithm resulted in a marked improvement of the proportion of patients within the AUC(MTX) target between 1000 and 1100 µmol l(-1) h (11% with standard MTX dose, 35% with the adjusted dose) and a marked reduction of the interindividual variability of MTX exposure. A simple and practical dosing algorithm for HDMTX has been developed based on MTX 24 h plasma concentrations, and its potential efficacy in improving the proportion of patients within a prespecified target AUC(MTX) and reducing the interindividual variability of MTX exposure has been shown by data simulations. The clinical benefit of this dosing algorithm should be assessed in patients with primary central nervous system lymphoma (PCNSL). © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.

  18. On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations

    Science.gov (United States)

    Fogliata, Antonella; Vanetti, Eugenio; Albers, Dirk; Brink, Carsten; Clivio, Alessandro; Knöös, Tommy; Nicolini, Giorgia; Cozzi, Luca

    2007-03-01

    A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho correction; Nucletron Helax-TMS: the collapsed cone and the pencil beam with equivalent path length correction; CMS XiO: the multigrid superposition and the fast Fourier transform convolution; Philips Pinnacle: the collapsed cone. Monte Carlo simulations (MC) performed with the EGSnrc codes BEAMnrc and DOSxyznrc from NRCC in Ottawa were used as a benchmark. The study was carried out in simple geometrical water phantoms (ρ = 1.00 g cm-3) with inserts of different densities simulating light lung tissue (ρ = 0.035 g cm-3), normal lung (ρ = 0.20 g cm-3) and cortical bone tissue (ρ = 1.80 g cm-3). Experiments were performed for low- and high-energy photon beams (6 and 15 MV) and for square (13 × 13 cm2) and elongated rectangular (2.8 × 13 cm2) fields. Analysis was carried out on the basis of depth dose curves and transverse profiles at several depths. Assuming the MC data as reference, γ index analysis was carried out distinguishing between regions inside the non-water inserts or inside the uniform water. For this study, a distance to agreement was set to 3 mm while the dose difference varied from 2% to 10%. In general all algorithms based on pencil-beam convolutions showed a systematic deficiency in managing the presence of heterogeneous media. In contrast, complicated patterns were observed for the advanced algorithms with significant discrepancies observed between algorithms in the lighter materials (ρ = 0.035 g cm-3), enhanced for the most energetic beam. For denser, and more clinical, densities a better agreement among the sophisticated algorithms with respect to MC was observed.

  19. Radiation dose in mammography: an energy-balance approach

    International Nuclear Information System (INIS)

    Shrivastava, P.N.

    1981-01-01

    An energy-balance approach for calculation of mean, integral, and midpoint doses in mammography is introduced. Estimation of mean absorbed dose for individual applications is described. Differences in breast composition and thickness are accounted for by simple measurements of entrance and exit exposures. Calculations made for a range of xeromammographic techniques used at various breast cancer detection centers show that although increasing the beam h.v.l. dramatically decreases breast surface exposure, it is insignificant in lowering mean breast dose or radiation risk. Thus selection of a moderate h.v.l. to optimize image quality (soft-tissue contrast) in xeromammography may be more beneficial than unduly increasing h.v.l. merely to reduce surface exposure. The mean breast dose per mammogram with low-h.v.l. screen-film techniques was 3 to 9 times lower than for xeromammography, suggesting that general acceptance of screen-film techniques can significantly reduce the risk associated with mammography

  20. Acute personalized habitual caffeine doses improve attention and have selective effects when considering the fractionation of executive functions.

    Science.gov (United States)

    Lanini, Juliana; Galduróz, José Carlos Fernandes; Pompéia, Sabine

    2016-01-01

    Caffeine is widely used, often consumed with food, and improves simple and complex/executive attention under fasting conditions. We investigated whether these cognitive effects are observed when personalized habitual doses of caffeine are ingested by caffeine consumers, whether they are influenced by nutriments and if various executive domains are susceptible to improvement. This was a double-blind, placebo-controlled study including 60 young, healthy, rested males randomly assigned to one of four treatments: placebo fasting, caffeine fasting, placebo meal and caffeine meal. Caffeine doses were individualized for each participant based on their self-reported caffeine consumption at the time of testing (morning). The test battery included measures of simple and sustained attention, executive domains (inhibiting, updating, shifting, dual tasking, planning and accessing long-term memory), control measures of subjective alterations, glucose and insulin levels, skin conductance, heart rate and pupil dilation. Regardless of meal intake, acute habitual doses of caffeine decreased fatigue, and improved simple and sustained attention and executive updating. This executive effect was not secondary to the habitual weekly dose consumed, changes in simple and sustained attention, mood, meal ingestion and increases in cognitive effort. We conclude that the morning caffeine "fix" has positive attentional effects and selectively improved executive updating whether or not caffeine is consumed with food. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Produtividade e classificação de brócolos para indústria em função da adubação nitrogenada e potássica e dos espaçamentos entre plantas Yield and classification of broccoli depending on fertilizing and spacing between plants

    Directory of Open Access Journals (Sweden)

    Arthur B Cecílio Filho

    2012-03-01

    Full Text Available No município de Itatiba-SP, no período de março a julho de 2007, foi realizado um experimento com o objetivo de avaliar doses de nitrogênio e potássio e espaçamentos entre plantas na produtividade e classificação de brócolos para indústria. O experimento foi instalado sob delineamento de blocos ao acaso, com os tratamentos em esquema fatorial 5 x 4, e três repetições, sendo avaliadas as doses de nitrogênio-potássio: 105-105; 157,5-157,5; 210-210; 262,5-262,5 e 315-315 kg ha-1 de N e K2O e os espaçamentos entre plantas: 0,2; 0,3; 0,4 e 0,5 m. O espaçamento entre linhas foi de 0,8 m. Foram avaliados o teor foliar de nitrogênio (TN e de potássio (TP, produtividade de inflorescência (PI, produtividade de floretes (PF, rendimento industrial (RI e classificação dos floretes com base em seu comprimento: PF5 (5 e 7 e 9 cm. Maiores espaçamentos entre plantas proporcionaram maior TN e menores PI e PF. As doses NK e os espaçamentos entre plantas não influenciaram significativamente o TP e o RI. As maiores produtividades de inflorescências (22,08 t ha-1 e de floretes (17,09 t ha-1 foram obtidas com 0,20 m entre plantas e 315 kg ha-1 de N e de K2O. Maior percentagem de floretes na classe PF5 foi obtida no menor espaçamento entre plantas. As doses NK e os espaçamentos entre plantas não influenciaram as percentagens de floretes nas classes PF79 e PF9.In Itatiba, São Paulo state, Brazil, during the period between March and July of 2007, an experiment was carried out aiming to appraise the effect of doses of nitrogen and potassium (105-105, 157.5-157.5, 210-210, 262.5-262.5 and 315-315 kg ha-1 N and K2O and spacing between plants (0.2, 0.3, 0.4 and 0.5 m upon the yield of broccoli and their classification. The experimental design was carried out in a randomized block, with the treatments in a 5 x 4 factorial scheme and three replications. Rows of plants were 0.8 m apart. The following characteristics were evaluated: foliar content

  2. DNA Comet Assay. A simple screening technique for identification of some irradiated foods

    International Nuclear Information System (INIS)

    Khan, A.A.; Khan, H.M.

    2008-01-01

    DNA Comet Assay method was carried out to detect irradiation treatment of some foods like meat, spices, beans and lentils. The fresh meat of cow and duck were irradiated up to radiation doses of 3 kGy, the spices (cardamoms and cumin black) were irradiated to radiation doses of 5, 10, 15 and 20 kGy while the beans (black beans and white beans) and lentils (red and green lentils) were irradiated to 0.5 and 1 kGy. All the foods were then analyzed for radiation treatment using simple microgel electrophoresis of single cells or nuclei (DNA Comet Assay). Sedimentation, lysis and staining times were adjusted to get optimized conditions for correct and easy analysis of each food. Using these optimized conditions, it was found out that radiation damaged DNA showed comets in case of irradiated food samples, whereas in non-treated food samples, round or conical spots of stained DNA were visible. Shape, length and intensity of these comets were also radiation dose dependent. Screening of unirradiated and irradiated samples by Comet Assay was successful in the case of all the foods under consideration under the optimized conditions of assay. Therefore, for different kinds of irradiated foods studied in the present study, the DNA Comet Assay can be used as a rapid, simple and inexpensive screening test. (author)

  3. Imaging and Measuring Electron Beam Dose Distributions Using Holographic Interferometry

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    Holographic interferometry was used to image and measure ionizing radiation depth-dose and isodose distributions in transparent liquids. Both broad and narrowly collimated electron beams from accelerators (2–10 MeV) provided short irradiation times of 30 ns to 0.6 s. Holographic images...... and measurements of absorbed dose distributions were achieved in liquids of various densities and thermal properties and in water layers thinner than the electron range and with backings of materials of various densities and atomic numbers. The lowest detectable dose in some liquids was of the order of a few k......Rad. The precision limits of the measurement of dose were found to be ±4%. The procedure was simple and the holographic equipment stable and compact, thus allowing experimentation under routine laboratory conditions and limited space....

  4. EL ABUSO DEL DERECHO: ENTRE LA MODERNIDAD Y LA POSMODERNIDAD

    Directory of Open Access Journals (Sweden)

    Gunther Gonzales Barrón

    2015-12-01

    Full Text Available The abuse of law is one of those legal concepts from which all speak, almost by intuition or common sense, and jurisprudence is not the exception, in their desire to support a decision allegedly tainted justice can use a simple phrase like all motivation. That is the risk of general legal concepts, but also its advantage as the indeterminacy allows the judge to address issues not regulated without reference to positivism, but get out of those narrow limits requires a strong argument justifying the sentence dose on grounds of practical rationality. The danger of generality amendment argument.

  5. Decomposition analysis of differential dose volume histograms

    International Nuclear Information System (INIS)

    Heuvel, Frank van den

    2006-01-01

    Dose volume histograms are a common tool to assess the value of a treatment plan for various forms of radiation therapy treatment. The purpose of this work is to introduce, validate, and apply a set of tools to analyze differential dose volume histograms by decomposing them into physically and clinically meaningful normal distributions. A weighted sum of the decomposed normal distributions (e.g., weighted dose) is proposed as a new measure of target dose, rather than the more unstable point dose. The method and its theory are presented and validated using simulated distributions. Additional validation is performed by analyzing simple four field box techniques encompassing a predefined target, using different treatment energies inside a water phantom. Furthermore, two clinical situations are analyzed using this methodology to illustrate practical usefulness. A comparison of a treatment plan for a breast patient using a tangential field setup with wedges is compared to a comparable geometry using dose compensators. Finally, a normal tissue complication probability (NTCP) calculation is refined using this decomposition. The NTCP calculation is performed on a liver as organ at risk in a treatment of a mesothelioma patient with involvement of the right lung. The comparison of the wedged breast treatment versus the compensator technique yields comparable classical dose parameters (e.g., conformity index ≅1 and equal dose at the ICRU dose point). The methodology proposed here shows a 4% difference in weighted dose outlining the difference in treatment using a single parameter instead of at least two in a classical analysis (e.g., mean dose, and maximal dose, or total dose variance). NTCP-calculations for the mesothelioma case are generated automatically and show a 3% decrease with respect to the classical calculation. The decrease is slightly dependant on the fractionation and on the α/β-value utilized. In conclusion, this method is able to distinguish clinically

  6. Simple DVH parameter addition as compared to deformable registration for bladder dose accumulation in cervix cancer brachytherapy

    DEFF Research Database (Denmark)

    Andersen, Else Stougård; Noe, Karsten Østergaaard; Sørensen, Thomas Sangild

    2013-01-01

    Background and purpose: Variations in organ position, shape, and volume cause uncertainties in dose assessment for brachytherapy (BT) in cervix cancer. The purpose of this study was to evaluate uncertainties associated with bladder dose accumulation based on DVH parameter addition (previously...... called "the worst case assumption") in fractionated BT. Materials and methods: Forty-seven patients treated for locally advanced cervical cancer were included. All patients received EBRT combined with two individually planned 3D image-guided adaptive BT fractions. D2 and D0.1 were estimated by DVH...

  7. Design of simple UV Spectrophotometric and HPLC methods for assay of artesunate and amodiaquine in fixed dose tablet formulations

    International Nuclear Information System (INIS)

    Ashie, Agatha Dei

    2013-07-01

    Artesunate and Amodiaquine combination is one of the first line drugs for the treatment of uncomplicated malaria. To prevent treatment failures and emergence of resistant strains of the Plasmodium parasite, patients are entreated to comply with treatment regimens. Thus fixed dose tablet formulations came as a relieve to patients, ensuring proper compliance as the number of tablets to be taken was reduced. It is therefore important to develop simple methods of assay for these formulations to ensure that quality drugs are available and to prevent resistance to these drugs. This thesis describes Ultraviolet (UV) and High Performance Liquid Chromatographic (HPLC) methods of assay for Artesunate (AS) and Amodiaduine Hydrochloride (AMQ) in fixed dose tablet formulations. The UV absorption spectroscopy was used to establish a wavelength of maximum absorption and the Beer’s plot generated. At 339nm, Amodiaquine Hydrochloride was assayed accurately in methanol with a high r"2 value of 0.998, an intra and inter day precision of Relative Standard Deviation (RSD) of 1.52% and 1.86% respectively. The Beer’s plot was obeyed in a concentration range of 3.5 - 24.8(µg/mL). The limit of detection and limit of quantification was 1.23(µg/mL) and 3.73(µg/mL) respectively. However the UV method could not be used to assay AS simultaneously with AMQ. A mobile phase of 60% acetonitrile and 40% of 0.05% trifluoroacetic acid, flow rate of 1ml/min, wavelength of detection of 225nm and a C_1_8 stationary phase are the parameters for the HPLC method. The r"2 for the HPLC method was 0.996 and 0.995 for Amodiaquine hydrochloride and Artesunate respectively. The intra and inter day precision were 1.07% and 1.42% respectively. The limit of detection and limit of quantification were 0.015%w/v and 0.0465%w/v for Amodiaquine hydrochloride and 0.054%w/v and 0.019%w/v for Artesunate respectively. The concentration ranges were 0.01 - 0.16%w/v for Amodiaquine hydrochloride and 0.01 – 0.2%w/v for

  8. Indoor aerosol modeling for assessment of exposure and respiratory tract deposited dose

    Science.gov (United States)

    Hussein, Tareq; Wierzbicka, Aneta; Löndahl, Jakob; Lazaridis, Mihalis; Hänninen, Otto

    2015-04-01

    Air pollution is one of the major environmental problems that influence people's health. Exposure to harmful particulate matter (PM) occurs both outdoors and indoors, but while people spend most of their time indoors, the indoor exposures tend to dominate. Moreover, higher PM concentrations due to indoor sources and tightness of indoor environments may substantially add to the outdoor originating exposures. Empirical and real-time assessment of human exposure is often impossible; therefore, indoor aerosol modeling (IAM) can be used as a superior method in exposure and health effects studies. This paper presents a simple approach in combining available aerosol-based modeling techniques to evaluate the real-time exposure and respiratory tract deposited dose based on particle size. Our simple approach consists of outdoor aerosol data base, IAM simulations, time-activity pattern data-base, physical-chemical properties of inhaled aerosols, and semi-empirical deposition fraction of aerosols in the respiratory tract. These modeling techniques allow the characterization of regional deposited dose in any metric: particle mass, particle number, and surface area. The first part of this presentation reviews recent advances in simple mass-balance based modeling methods that are needed in analyzing the health relevance of indoor exposures. The second part illustrates the use of IAM in the calculations of exposure and deposited dose. Contrary to previous methods, the approach presented is a real-time approach and it goes beyond the exposure assessment to provide the required information for the health risk assessment, which is the respiratory tract deposited dose. This simplified approach is foreseen to support epidemiological studies focusing on exposures originating from both indoor and outdoor sources.

  9. Uncertainty and power at low levels of incurred radiation dose

    International Nuclear Information System (INIS)

    Wilson, M; Jackson, D

    2005-01-01

    It is common practice when calculating dose to exposed populations to average the variables that go into the dose calculation (e.g. environmental concentrations, air kerma, consumption rates, occupancy rates). This approach is simple and can be useful where data are obtained over different periods (weekly, monthly, quarterly), where samples may be bulked for some analyses but not others and where gaps in the data are present. However, such an approach does not yield information on the degree of uncertainty around the average dose calculated. An alternative approach is to estimate the dose to each individual and to obtain an average from this data set, which can then also be used to derive a measure of uncertainty around the central dose estimate. In this study, we demonstrate the variability in dose estimates using a hypothetical data set and consider the implications for sample size to achieve fixed confidence or resolving power. We recommend calculating the dose to every individual sampled, in order both to obtain the average dose and to estimate its variability. We argue that it is best practice to obtain information as complete as possible from the available sample of individuals

  10. IMRT in a pregnant patient: how to reduce the fetal dose?

    DEFF Research Database (Denmark)

    Josipovic, Mirjana; Nyström, Håkan; Kjaer-Kristoffersen, Flemming

    2008-01-01

    dose distribution. The peripheral dose originating from the final IMRT plan was measured at distances reaching from the most proximal to the most distal fetal position, along the accelerator's longitudinal axis, using an anthropomorphic phantom extended with water-equivalent plastic. The measured...... was built and placed beneath the accelerator head, extending caudally from the field edge, to function as an extra collimator jaw. This shield reduced the fetal dose by a factor of 3.5. The peripheral dose components were also measured for simple rectangular fields and also here the collimator scatter...... was the greatest contributor to the peripheral dose. Therefore, the shielding used for the IMRT treatment of our patient could also be used when shielding in conventional radiotherapy. It is important for a radiation therapy department to be prepared for treatment of a pregnant patient to shield the fetus...

  11. Measurement and monitoring of entrance exposure dose rate in X-ray image intensifier television with dose rate control

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J [Bezirkskrankenhaus Brandenburg (German Democratic Republic)

    1981-03-01

    For X-ray image intensifier television operation very low entrance dose rates (about 5.2 nA/kg) are stated and demanded, respectively. These required values are often manifold exceeded in practice so that a check seems to be necessary. It is shown and proved how these measurements can be performed with simple, generally available means of measurement in the radiological practice. For ZnCdS-image intensifiers should be considered that about 13 nA/kg for the large entrance size are not to be exceeded; for the CsI type lower values (factor 1.5) are practicable because of the twofold quantum absorption efficiency. Furthermore, some tests for a semiquantitative function check of the automatic dose rate control are proposed.

  12. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W. Sr.

    1992-01-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system use relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, Monte Carlo calculations were performed using the code Electron Gamma Shower (EGS4). Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessel sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was or cross fire between blood vessels was assumed. Results are useful in assessing the doses to blood and blood vessel walls for different nuclear medicine procedures

  13. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W.

    1991-05-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system used relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, EGS4 Monte Carlo calculations were performed. Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessels sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was assumed nor cross fire between vessel was assumed. Results are useful in assessing the dose in blood and blood vessel walls for different nuclear medicine procedures. 6 refs., 6 figs., 5 tabs

  14. Skin entrance dose - thyroid: comparison between three kinds of dental appliances; Dose de entrada na pele - tireóide: comparativo entre três tipos de aparelhos odontológicos

    Energy Technology Data Exchange (ETDEWEB)

    Savi, M.; Viana, E.; Soares, F.A., E-mail: matheus.savi@ifsc.edu.br [Dept. Acadêmico de Saúde e Serviços/CST em Radiologia, Instituto Federal de Santa Catarina, Florianópolis (Brazil)

    2017-07-01

    Patient dosimetry is necessary to determine dosimetric quantities, establish reference levels for radio-diagnosis and assess health risks. Part of the radiation beam of the appliances that penetrates the patient's body is absorbed by tissues and part is spread and its sum is known as the Dose of Entrance into the Skin. The objective of this study is to know and compare the DEP of dental radiology devices in the thyroid gland. Two periapical, panoramic and computerized conical beam tomographs were used in this study at a private dentistry clinic and at the Federal Institute of Santa Catarina. The periapical apparatus produced the highest total dose of radiation, as well as a higher dose rate, followed by CBCT and panoramic.

  15. Doses de fósforo e zinco na cultura do alho em condições de casa de vegetação Doses of phosphorus and zinc on garlic crop in greenhouse

    Directory of Open Access Journals (Sweden)

    Leonardo Theodoro Büll

    2008-12-01

    Full Text Available A adubação fosfatada promove o aumento de produtividade na cultura do alho, mas doses de fósforo (P podem proporcionar a deficiência de zinco (Zn na planta, sobretudo em solos com baixos teores deste micronutriente. O objetivo do trabalho foi verificar o efeito da interação entre P e Zn no solo sobre o desenvolvimento e produção de plantas de alho. Foram instalados três experimentos, cada um com um tipo de solo, em vasos com 17 kg de solo, em casa de vegetação telada. Empregou-se delineamento em blocos casualizados em esquema fatorial com 4 doses de P (0, 100, 200 e 400 mg dm-3 utilizando-se superfosfato triplo e 4 doses de Zn (0, 2,5, 5,0 e 10 mg dm-3 aplicados na forma de ZnSO4.7H2O, ambos incorporados ao solo, com três repetições. A produtividade e o desenvolvimento de plantas de alho foram influenciados, isoladamente, pelas doses de P e Zn, não havendo a interação entre esses nutrientes. Para os solos Neossolo Quartzarênico (NQ textura arenosa, Latossolo Vermelho Distrófico (LE textura média e Latossolo Vermelho Distroférrico (LR, textura argilosa, as melhores doses de P para a produção de alho foram de 190, 400 e 400 mg dm-3 e para o Zn de 2,2; 6,5 e 5,1 mg dm-3 respectivamente.Phosphate fertilization increases garlic yield, but high doses of phosphorus (P may cause zinc deficiency (Zn in plants, mainly when the soil presents low contents of this micronutrient. This paper aimed to verify the effect of P and Zn interaction in the soil on the development and yield of garlic bulbs ("Roxo Pérola de Caçador" cultivar. Three experiments were carried out under screened greenhouse conditions, using three soils of different texture and 17 kg pots. They had a randomized factorial block design, 4 doses of P (0, 100, 200 and 400 mg dm-3 , 4 doses of Zn (0, 2,5, 5,0 and 10 mg dm-3, both applied as ZnSO4.7H2O, and three replications. Garlic bulb development and yield were influenced by doses of P and Zn; there was no interaction

  16. Dose econômica de calcário na produtividade de caramboleiras

    Directory of Open Access Journals (Sweden)

    William Natale

    2011-12-01

    Full Text Available Com o objetivo de estudar a relação entre doses de calcário e produção de carambolas, um experimento de campo foi conduzido em um Latossolo Vermelho distrófico, no município de Bebedouro(SP, no período de 1999 a 2006. O delineamento adotado foi o em blocos casualizados, com cinco tratamentos e quatro repetições. O calcário foi aplicado uma única vez em 1999, nas doses de: 0; 1,85; 3,71; 5,56 e 7,41 t ha-1. A produção das caramboleiras aumentou em resposta à aplicação do corretivo de acidez. As produções acumuladas de frutos, nos anos sucessivos de 2003, 2004, 2005 e 2006, estiveram associadas às doses mais econômicas de calcário de 4,5; 4,8; 5,3 e 5,3 t ha-1, respectivamente.

  17. El periodista, entre el Poder

    Directory of Open Access Journals (Sweden)

    JL Dader

    2014-10-01

    Full Text Available El periodismo se debate, desde sus orígenes, entre la reproducción servil de versiones interesadas o la distorsión de propio cuño, por conocimiento insuficiente de una realidad que sólo puede entrever. Los poderes que amenazan la independencia periodística no han hecho más que crecer o aumentar su habilidad con el paso del tiempo. Surgido como ‘oficio de esclavos’ en la época romana, muchos indicadores actuales parecen retornarle al punto de partida: relaciones públicas estratégicas a gran escala, auge de los ‘spin doctors’, extorsión descarnada en las democracias más débiles y populismo de las redes sociales, entre otros. Todo ello, unido o alentado por la degradación interna y el desaliento de la propia institución periodística incapaz de distanciarse de todas esas fuerzas. Su respuesta no puede ser de alianza o competencia con los poderes que la circundan, sino de hábil distanciamiento para moverse entre todos ellos sin dejar de ejercer la vigilancia que los ciudadanos siguen necesitando de su ejercicio profesional.

  18. The application of artificial neural networks to TLD dose algorithm

    International Nuclear Information System (INIS)

    Moscovitch, M.

    1997-01-01

    We review the application of feed forward neural networks to multi element thermoluminescence dosimetry (TLD) dose algorithm development. A Neural Network is an information processing method inspired by the biological nervous system. A dose algorithm based on a neural network is a fundamentally different approach from conventional algorithms, as it has the capability to learn from its own experience. The neural network algorithm is shown the expected dose values (output) associated with a given response of a multi-element dosimeter (input) many times.The algorithm, being trained that way, eventually is able to produce its own unique solution to similar (but not exactly the same) dose calculation problems. For personnel dosimetry, the output consists of the desired dose components: deep dose, shallow dose, and eye dose. The input consists of the TL data obtained from the readout of a multi-element dosimeter. For this application, a neural network architecture was developed based on the concept of functional links network (FLN). The FLN concept allowed an increase in the dimensionality of the input space and construction of a neural network without any hidden layers. This simplifies the problem and results in a relatively simple and reliable dose calculation algorithm. Overall, the neural network dose algorithm approach has been shown to significantly improve the precision and accuracy of dose calculations. (authors)

  19. Radiation-induced temporary partial epilation in the pig: a biological indicator of radiation dose and dose distribution to the skin

    International Nuclear Information System (INIS)

    Sieber, V.K.; Hopewell, J.W.

    1990-01-01

    Radiation damage to the matrix cells of actively growing hairs can result in transient epilation in the pig, the severity of which can be assessed using a visual scoring system. The extent of hair loss was found to be dose-dependent for single doses in the range 6 - 14 Gy for 250 kV X rays. The ED 50 for detectable hair loss was 9.83 ± 0.58 Gy whilst that for the loss of > 50% of hairs was 13.78 ± 0.90 Gy. The system is simple, non-invasive and would appear to have considerable potential for use in biological dosimetry for high exposures that are likely to require local treatment. (author)

  20. Motion-encoded dose calculation through fluence/sinogram modification

    International Nuclear Information System (INIS)

    Lu, Weiguo; Olivera, Gustavo H.; Mackie, Thomas R.

    2005-01-01

    Conventional radiotherapy treatment planning systems rely on a static computed tomography (CT) image for planning and evaluation. Intra/inter-fraction patient motions may result in significant differences between the planned and the delivered dose. In this paper, we develop a method to incorporate the knowledge of intra/inter-fraction patient motion directly into the dose calculation. By decomposing the motion into a parallel (to beam direction) component and perpendicular (to beam direction) component, we show that the motion effects can be accounted for by simply modifying the fluence distribution (sinogram). After such modification, dose calculation is the same as those based on a static planning image. This method is superior to the 'dose-convolution' method because it is not based on 'shift invariant' assumption. Therefore, it deals with material heterogeneity and surface curvature very well. We test our method using extensive simulations, which include four phantoms, four motion patterns, and three plan beams. We compare our method with the 'dose-convolution' and the 'stochastic simulation' methods (gold standard). As for the homogeneous flat surface phantom, our method has similar accuracy as the 'dose-convolution' method. As for all other phantoms, our method outperforms the 'dose-convolution'. The maximum motion encoded dose calculation error using our method is within 4% of the gold standard. It is shown that a treatment planning system that is based on 'motion-encoded dose calculation' can incorporate random and systematic motion errors in a very simple fashion. Under this approximation, in principle, a planning target volume definition is not required, since it already accounts for the intra/inter-fraction motion variations and it automatically optimizes the cumulative dose rather than the single fraction dose

  1. Fetal dose from radiotherapy photon beams: Physical basis, techniques to estimate radiation dose outside of the treatment field, biological effects and professional considerations

    International Nuclear Information System (INIS)

    Stovell, Marilyn; Blackwell, C. Robert

    1997-01-01

    Purpose/Objective: The presentation will review: 1. The physical basis of radiation dose outside of the treatment field. 2. Techniques to estimate and reduce fetal dose. 3. Clinical examples of fetal dose estimation and reduction. 4. Biological effects of fetal irradiation. 5. Professional considerations. Approximately 4000 women per year in the United States require radiotherapy during pregnancy. This report presents data and techniques that allow the medical physicist to estimate the radiation dose the fetus will receive and to reduce this dose with appropriate shielding. Out-of-beam data are presented for a variety of photon beams, including cobalt-60 gamma rays and x rays from 4 to 18 MV. Designs for simple and inexpensive to more complex and expensive types of shielding equipment are described. Clinical examples show that proper shielding can reduce the radiation dose to the fetus by 50%. In addition, a review of the biological aspects of irradiation enables estimates of the risks of lethality, growth retardation, mental retardation, malformation, sterility, cancer induction, and genetic defects to the fetus. A summary of professional considerations/recommendations is also provided as a guide for the radiation oncologist and medical physicist

  2. Superfractionation as a potential hypoxic cell radiosensitizer: prediction of an optimum dose per fraction

    International Nuclear Information System (INIS)

    Dasu, Alexandru; Denekamp, Juliana

    1999-01-01

    Purpose: A dose 'window of opportunity' has been identified in an earlier modeling study if the inducible repair variant of the LQ model is adopted instead of the pure LQ model, and if all survival curve parameters are equally modified by the presence or absence of oxygen. In this paper we have extended the calculations to consider survival curve parameters from 15 sets of data obtained for cells tested at low doses using clonogenic assays. Methods and Materials: A simple computer model has been used to simulate the response of each cell line to various doses per fraction in multifraction schedules, with oxic and hypoxic cells receiving the same fractional dose. We have then used pairs of simulated survival curves to estimate the effective hypoxic protection (OER') as a function of the dose per fraction. Results: The resistance of hypoxic cells is reduced by using smaller doses per fraction than 2 Gy in all these fractionated clinical simulations, whether using a simple LQ model, or the more complex LQ/IR model. If there is no inducible repair, the optimum dose is infinitely low. If there is inducible repair, there is an optimum dose per fraction at which hypoxic protection is minimized. This is usually around 0.5 Gy. It depends on the dose needed to induce repair being higher in hypoxia than in oxygen. The OER' may even go below unity, i.e. hypoxic cells may be more sensitive than oxic cells. Conclusions: If oxic and hypoxic cells are repeatedly exposed to doses of the same magnitude, as occurs in clinical radiotherapy, the observed hypoxic protection varies with the fractional dose. The OER' is predicted to diminish at lower doses in all cell lines. The loss of hypoxic resistance with superfractionation is predicted to be proportional to the capacity of the cells to induce repair, i.e. their intrinsic radioresistance at a dose of 2 Gy

  3. Predictions of dose from electrons in space

    Science.gov (United States)

    Seltzer, Stephen M.

    1992-01-01

    The objective of the project is to develop a general-purpose, user-friendly computerized database and code package, for the PC as well as larger computers, which can be used for the routine prediction of the absorbed dose from incident electrons and their secondary bremsstrahlung (and from incident protons) as functions of the thickness of aluminum shielding in space. The assumption of homogeneous aluminum shields and of isotropic incident fluxes (at least in a time-averaged sense) allows for the rather reliable conversion of doses in slabs to those in other simple bodies, such as spherical and cylindrical solids and shells. On such a basis, depth-dose data for monoenergetic incident radiation can be generated once-and-for-all from accurate transport calculations, and this database can then be used repeatedly in rapid dose predictions for arbitrary radiation spectra and for a variety of spacecraft sizes and shapes, without recourse to the very time-consuming Monte Carlo calculations. This project entails a thorough updating, extension, and refinement of our earlier SHIELDOSE package, with the goal of a more reliable, fool-proof, and general system.

  4. Superfosfato simples e cloreto de potássio na formação de porta-enxerto de sapotizeiro [Manilkara zapota (L.) Von Royen

    OpenAIRE

    Mendonça,Vander; Corrêa,Fernando Luíz de Oliveira; Pio,Rafael; Rufini,José Carlos Moraes; Carrijo,Edney Paulo; Ramos,José Darlan

    2007-01-01

    Objetivou-se com este estudo avaliar o efeito da aplicação de superfosfato simples e cloreto de potássio no desenvolvimento de porta-enxerto de sapotizeiro até a época de enxertia. O delineamento experimental utilizado foi em blocos casualizados em esquema fatorial 4 x 4, sendo quatro doses de superfosfato simples (0; 2,5; 5 e 10 kg m-3 de substrato) e quatro doses de cloreto de potássio (0; 1; 2 e 4 kg m-3 de substrato) com quatro repetições e duas plantas por parcela. Os porta-enxertos fora...

  5. Okadaic acid for radiation dose estimation using drug-induced premature chromosome condensation

    International Nuclear Information System (INIS)

    Wang Chunyan; Zhang Wei; Su Xu

    2005-01-01

    Objective: To establish simple biological method for high irradiation dose estimation using drug-induced prematurely condensed chromosomes (PCC) aberrations. Methods: Peripheral blood was taken from healthy adults and irradiated by 0, 1, 2, 5, 10, 15, 20 and 25 Gy 60 Co γ-rays. Then the blood samples were cultured for 48 hrs. One hr before the end of culture , okadaic acid was added into culture medium to induce PCC rings, which were counted for each dose point. Results: The yield of PCC rings was increased with the dose of radiation until 20 Gy. Within the range of 1 to 20 Gy, there was a good dose-response relationship between the yield of PCC rings and radiation dose. Conclusion: Compared with the analysis of frequency of dicentrics, the yield of PCC rings could be a good biodosimetry indicator for estimation of high dose irradiation. (authors)

  6. Intercomparison and calibration of dose calibrators used in nuclear medicine facilities

    CERN Document Server

    Costa, A M D

    2003-01-01

    The aim of this work was to establish a working standard for intercomparison and calibration of dose calibrators used in most of nuclear medicine facilities for the determination of the activity of radionuclides administered to patients in specific examinations or therapeutic procedures. A commercial dose calibrator, a set of standard radioactive sources, and syringes, vials and ampoules with radionuclide solutions used in nuclear medicine were utilized in this work. The commercial dose calibrator was calibrated for radionuclide solutions used in nuclear medicine. Simple instrument tests, such as linearity response and variation response with the source volume at a constant source activity concentration were performed. This instrument may be used as a reference system for intercomparison and calibration of other activity meters, as a method of quality control of dose calibrators utilized in nuclear medicine facilities.

  7. Fatores associados à imunização contra Hepatite B entre trabalhadores da Estratégia Saúde da Família

    Directory of Open Access Journals (Sweden)

    Andréa Maria Eleutério de Barros Lima Martins

    2015-02-01

    Full Text Available Estudo transversal conduzido entre trabalhadores da Estratégia Saúde da Família de Montes Claros. Objetivo: investigar o relato de vacinação contra Hepatite B, a verificação da imunização e os fatores associados às dosagens de anti-HBs. Método: coletaram-se amostras de sangue daqueles que relataram ter recebido uma ou mais doses da vacina. Avaliou-se a associação da dosagem de anti-HBs com condições sociodemográficas, ocupacionais e comportamentais. As associações foram verificadas pelos testes Mann Whitney e Kruskal Wallis e correlação de Spermann seguida pela regressão linear, utilizou-se o SPSS® 17.0. Resultados: dentre os 761 entrevistados, 504 (66,1% foram vacinados, 52,5% tomaram três doses, 30,4% verificaram a imunização. Dos 397 avaliados quanto à dosagem de anti-HBs, 16,4% estavam imunes. Conclusão: constatou-se que o maior tempo de trabalho foi associado a níveis mais elevados de anti-HBs, enquanto os níveis de tabagismo foram inversamente associados ao anti-HBs. Há necessidade de campanhas de vacinação entre esses trabalhadores.

  8. The Use Of Optical Properties Of Cr-39 In Alpha Particle Equivalent Dose Measurements

    International Nuclear Information System (INIS)

    Shnishin, K.A.

    2007-01-01

    In this work, optical properties of alpha irradiated Cr-39 were measured as a function of optical photon wavelength from 200-1100 nm. Optical energy gap and optical absorption at finite wavelength was also calculated and correlated to alpha fluence and dose equivalent. Alpha doses were calculated from the corresponding irradiation fluence and specific energy loss using TRIM computer program. It was found that, the optical absorption of unattached Cr-39 was varied with alpha fluence and corresponding equivalent doses. Also the optical energy gab was varied with fluence and dose equivalent of alpha particles. This work introduces a reasonably simple method for the Rn dose equivalent calculation by Cr-39 track

  9. Dose in the uterus of a woman, with three months of pregnancy, due to the 131 I accumulated in her thyroid gland

    International Nuclear Information System (INIS)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Arcos P, A.

    2006-01-01

    In this study the absorbed dose by the uterus of a woman with three months of pregnancy to who was applied a dose of 131 I that was accumulated in the thyroid gland is determined. The absorbed dose was obtained by means of Monte Carlo calculations developing a detailed three-dimensional model of the pregnant one, where they have been included most of the organs. The absorbed dose also was calculated by means of a simple procedure. To verify the calculated results it was carried out an experiment where was constructed a phantom of the neck, in this was included the thyroid with 131 I and the exposure was measured at different distances of the neck; this was related with the dose. Of the Monte Carlo calculation is obtained that for each mCi of 131 I that is retained in the mother's thyroid, the uterus absorbs a dose of 6.80 E(-11) Gy. When comparing the results, it was found that the simple calculation throws a result 29 times superior to that of the dose obtained by means of Monte Carlo. When applying a correction for the effect of the absorption of the gamma photons by the mother's body an absorbed dose in the uterus was obtained that is 0.16 times superior to the Monte Carlo calculation. Of the experimental phase it is verified that the values calculated by means of the simple method are equal to those experimentally measured. (Author)

  10. Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women La exactitud del examen de orina simple para diagnosticar infecciones del tracto urinario en gestantes de bajo riesgo Acurácia do exame de urina simples para diagnóstico de infecções do trato urinário em gestantes de baixo risco

    Directory of Open Access Journals (Sweden)

    Danielle Cristina Alves Feitosa

    2009-08-01

    Full Text Available Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI. This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV and negative (NPV predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%. In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%. It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.Las alteraciones anatómicas y fisiológicas de la gravidez predisponen a las gestantes a infecciones del tracto urinario (ITU. El objetivo de este estudio fue identificar la exactitud del examen de orina simple para diagnosticar ITU en gestantes de bajo riesgo. Se hizo uso del estudio de desempeño de prueba de diagnóstico realizado en Botucatu, San Pablo, con 230 gestantes, entre 2006 y 2008. Los resultados muestran que la prevalencia de ITU fue de 10%. La sensibilidad fue 95,6%, la especificidad 63,3% y la exactitud 66,5% del examen de orina simple, en relación al diagnóstico de ITU. El análisis de los valores de predicción positivo y negativo (VPP y VPN mostró que, en la vigencia de examen de orina simple normal, la probabilidad de haber ITU fue pequeña (VPN 99,2%. Frente al resultado alterado de ese examen, la probabilidad de haber ITU fue baja (VPP 22,4%. Se concluye que la exactitud del examen de orina simple como medio de diagnóstico de ITU fue baja, siendo indispensable la realizaci

  11. Variabilidade clínica na determinação da dose tóxica oral em intoxicação experimental por fluoroacetato de sódio em gatos

    Directory of Open Access Journals (Sweden)

    Rita de Cássia Collicchio-Zuanaze

    2006-02-01

    Full Text Available O fluoroacetato de sódio (FAS ou composto 1080 é um potente rodenticida utilizado no controle de roedores e predadores mamíferos. Sua utilização está proibida por lei em diversos países devido à sua alta toxicidade, mas no Brasil há evidências do uso ilegal e sem critérios causando intoxicações, principalmente em crianças e animais domésticos. O FAS age por meio do seu metabólito tóxico, o fluorocitrato, no bloqueio do ciclo de Krebs com conseqënte diminuição da produção de energia do organismo, provocando principalmente manifestações clínicas neurológicas e cardíacas. No presente estudo compararam quatro doses orais tóxicas do fluoroacetato de sódio, descritas em gatos, na literatura, observando-se o aparecimento dos sinais clínicos predominantes da intoxicação, as diferenças entre as doses quanto a variabilidade clínica em relação ao período de latência para o aparecimento dos sinais clínicos e sua respectiva intensidade. A dose oral tóxica que melhor caracterizou o quadro clínico da intoxicação por FAS em gatos, sem causar a letalidade aguda, foi de 0,45mg/kg. As diferenças entre as manifestações clínicas foram dose-dependentes e em ordem crescente de intensidade, caracterizando-se como sinais leves (dose 1: 0,3mg/kg, leves a moderados (dose 2: 0,4mg/kg, moderados a graves (dose 3: 0,45mg/kg e graves (dose 4: 0,5mg/kg. Houve também variabilidade clínica individual entre animais intoxicados com a mesma dosagem do tóxico.

  12. Estimation dose of secondary neutrons in proton therapy

    International Nuclear Information System (INIS)

    Urban, T.

    2014-01-01

    Most of proton therapy centers for cancer treatment are still based on the passive scattering, in some of them there is system of the active scanning installed as well. The aim of this study is to compare secondary neutron doses in and around target volumes in proton therapy for both treatment techniques and for different energies and profile of incident proton beam. The proton induced neutrons have been simulated in the very simple geometry of tissue equivalent phantom (imitate the patient) and scattering and scanning nozzle, respectively. In simulations of the scattering nozzle, different types of scattering filters and brass collimators have been used as well. 3D map of neutron doses in and around the chosen/potential target volume in the phantom/patient have been evaluated and compared in the context of the dose deposited in the target volume. Finally, the simulation results have been compared with published data. (author)

  13. Bases del intercambio entre las sociedades norperuanas y surecuatorianas: una zona de transición entre 1500 A.C. y 600 D.C

    Directory of Open Access Journals (Sweden)

    1993-01-01

    Full Text Available BASES DE L'ECHANGE ENTRE LES SOCIETES NORD-PERUVIENNES ET SUD-EQUATORIENNES : UNE ZONE DE TRANSITION ENTRE 1500 AV. J.C. ET 600 AP. J.C. Cet article est le fruit d’une tentative de coopération entre des chercheurs qui travaillent en Équateur et au Pérou, pour relier les deux aires culturelles nettement différenciées, nord-andine et centre-andine, à partir de la définition et de l’étude d’une zone de transition, localisée entre le Río Jubones dans le sud de l'Équateur et le Río Olmos dans le nord du Pérou, entre environ 1500 av. J.C. et 600 ap. J.C. El artículo es resultado de un intento de cooperación entre investigadores que trabajan el Ecuador y el Perú para vincular las dos áreas culturales marcadamente diferenciadas, norandina y centroandina, a partir de la definición y estudio de una zona de transición, localizada entre el río Jubones, al sur de Ecuador y el Río Olmos, al norte de Perú, entre aproximadamente 1500 AC y 600 DC. BASIS OF THE EXCHANGE BETWEEN NORTH PERUVIAN AND SOUTH ECUATORIAN SOCIETIES: A TRANSITIONAL ZONE BETWEEN 1500 B.C. AND 600 A.C. This paper is a collaborative effort by researchers working in Ecuador and Peru, to explore the relationship between two clearly differentiated cultural areas (North and Central Andes on the basis of a definition and study of the prehistory transitional zone located between Río Jubones in Southern Ecuador and Río Olmos in Northern Peru between 1500 B.C. and 600 A.C.

  14. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Lahanas, M; Baltas, D; Zamboglou, N

    2003-01-01

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives

  15. Nonlinear model of high-dose implantation

    International Nuclear Information System (INIS)

    Danilyuk, A.

    2001-01-01

    The models of high-dose implantation, using the distribution functions, are relatively simple. However, they must take into account the variation of the function of distribution of the implanted ions with increasing dose [1-4]. This variation takes place owing to the fact that the increase of the concentration of the implanted ions results in a change of the properties of the target. High-dose implantation is accompanied by sputtering, volume growth, diffusion, generation of defects, formation of new phases, etc. The variation of the distribution function is determined by many factors and is not known in advance. The variation within the framework of these models [1-4] is taken into account in advance by the introduction of intuitive assumptions on the basis of implicit considerations. Therefore, these attempts should be regarded as incorrect. The model prepared here makes it possible to take into account the sputtering of the target, volume growth and additional declaration on the implanted ions. Without any assumptions in relation to the variation of the distribution function with increasing dose. In our model it is assumed that the type of distribution function for small doses in a pure target substance is the same as in substances with implanted ions. A second assumption relates to the type of the distribution function valid for small doses in the given substances. These functions are determined as a result of a large number of theoretical and experimental investigations and are well-known at the present time. They include the symmetric and nonsymmetric Gauss distribution, the Pearson distribution, and others. We examine implantation with small doses of up to 10 14 - 10 15 cm -2 when the accurately known distribution is valid

  16. Method for calculating individual equivalent doses and cumulative dose of population in the vicinity of nuclear power plant site

    International Nuclear Information System (INIS)

    Namestek, L.; Khorvat, D; Shvets, J.; Kunz, Eh.

    1976-01-01

    A method of calculating the doses of external and internal person irradiation in the nuclear power plant vicinity under conditions of normal operation and accident situations has been described. The main difference between the above method and methods used up to now is the use of a new antropomorphous representation of a human body model together with all the organs. The antropomorphous model of human body and its organs is determined as a set of simple solids, coordinates of disposistion of the solids, sizes, masses, densities and composition corresponding the genuine organs. The use of the Monte-Carlo method is the second difference. The results of the calculations according to the model suggested can be used for determination: a critical group of inhabitans under conditions of normal plant operation; groups of inhabitants most subjected to irradiation in the case of possible accident; a critical sector with a maximum collective dose in the case of an accident; a critical radioisotope favouring the greatest contribution to an individual equivalent dose; critical irradiation ways promoting a maximum contribution to individual equivalent doses; cumulative collective doses for the whole region or for a chosen part of the region permitting to estimate a population dose. The consequent method evoluation suggests the development of separate units of the calculationg program, critical application and the selection of input data of physical, plysiological and ecological character and improvement of the calculated program for the separate concrete events [ru

  17. CORRELAÇÃO ENTRE O IMC E AS CAPACIDADES MOTORAS CONDICIONAIS EM JOVENS PRATICANTES DE MODALIDADES DESPORTIVAS EXTRA-CURRICULARES

    Directory of Open Access Journals (Sweden)

    C. Alves

    2015-04-01

    Full Text Available As capacidades motoras são “a base para a capacidade de aprendizagem sensorial e motora”, responsáveis pela execução de uma ação, desde a mais simples à mais complexa (andar, correr, etc. (Moraes, 2003. Estas capacidades são condicionadas por fatores genéticos, contudo, desenvolvem-se através do treino, potenciando um elevado desempenho motor (Moraes, 2003. É, por isso, importante avaliar as capacidades motoras dos jovens, adequando por esta via, as experiências motoras a cada criança/grupo de crianças e/ou jovens (Neto, Marcarenhas, Nunes, Lepre & Campos, 2004. As relações entre a prática de atividade física e obesidade configuram-se como objeto de estudo prioritário e as evidências na literatura apontam para a existência de associação entre o excesso de peso na adolescência e alterações da sua saúde na idade adulta, dado o excesso de gordura corporal, além de ser fator de risco para diversas doenças, prejudica o desempenho físico. Objetivo: Analisar a associação entre o IMC e as Capacidades Motoras Condicionais em jovens praticantes de modalidades desportivas extra-curriculares.

  18. A simple approach for EPID dosimetric calibration to overcome the effect of image-lag and ghosting

    International Nuclear Information System (INIS)

    Alshanqity, Mukhtar; Duane, Simon; Nisbet, Andrew

    2012-01-01

    EPID dosimetry has known drawbacks. The main issue is that a measurable residual signal is observed after the end of irradiation for prolonged periods of time, thus making measurement difficult. We present a detailed analysis of EPID response and suggest a simple, yet accurate approach for calibration that avoids the complexity of incorporating ghosting and image-lag using the maximum integrated signal instead of the total integrated signal. This approach is linear with dose and independent of dose rate. - Highlights: ► Image-lag and ghosting effects dosimetric accuracy. ► Image-lag and ghosting result in the reduction of total integrated signal for low doses. ► Residual signal is the most significant result for the image-lag and ghosting effects. ► Image-lag and ghosting can result in under-dosing of up to 2.5%.

  19. Calculate the maximum expected dose for technical radio physicists a cobalt machine

    International Nuclear Information System (INIS)

    Avila Avila, Rafael; Perez Velasquez, Reytel; Gonzalez Lapez, Nadia

    2009-01-01

    Considering the daily operations carried out by technicians Radiophysics Medical Service Department of Radiation Oncology Hospital V. General Teaching I. Lenin in the city of Holguin, during a working week (Between Monday and Friday) as an important element in calculating the maximum expected dose (MDE). From the exponential decay law which is subject the source activity, we propose corrections to the cumulative doses in the weekly period, leading to obtaining a formula which takes into a cumulative dose during working days and sees no dose accumulation of rest days (Saturday and Sunday). The estimate factor correction is made from a power series expansion convergent is truncated at the n-th term coincides with the week period for which you want to calculate the dose. As initial condition is adopted ambient dose equivalent rate as a given, which allows estimate MDE in the moments after or before this. Calculations were proposed use of an Excel spreadsheet that allows simple and accessible processing the formula obtained. (author)

  20. Problems Concerning Dose Assessments in Epidemiology of High Background Radiation Areas of Yangjiang, China (invited paper)

    International Nuclear Information System (INIS)

    Wei, L.X.; Yuan, Y.L.

    1998-01-01

    The purpose of this study on radiation levels and dose assessments in the epidemiology of a high background radiation area (HBRA) and the control area (CA) is to respond to the needs of epidemiology in these areas, where the inhabitants are continuously exposed to low dose, low dose rate ionising radiation. A brief description is given of how the research group evaluated the feasibility of the investigation by analysing the population size and the radiation levels, how simple reliable methods were used to get the individual annual dose for every cohort member, and how the cohort members were classified into various dose groups for dose-effect relationship analysis. Finally, the use of dose group classification for cancer mortality studies is described. (author)

  1. Plasmodesmos: transporte simplástico de herbicidas na planta Plasmodesmata: symplastic transport of herbicides within the plant

    Directory of Open Access Journals (Sweden)

    G. Concenço

    2007-01-01

    Full Text Available Plasmodesmos são canais responsáveis pela conexão citoplasmática entre células vizinhas, possibilitando a troca de moléculas de informação, funcionais, estruturais ou ainda de xenobióticos entre as células pertencentes a um mesmo grupo. Células pertencentes ao mesmo conjunto (domínio constituem-se numa unidade funcional, e substâncias podem se mover entre estas células com velocidade muito superior à observada no transporte através de membranas. Os plasmodesmos podem atuar ainda no transporte a longa distância, tanto pela associação com o floema como pelo intercâmbio entre domínios simplásticos. Quando a planta se encontra sob estresse e as taxas de transporte via xilema e floema são mais reduzidas, os plasmodesmos podem ser mais efetivos no transporte a longa distância, das moléculas de herbicidas sistêmicos. Falta ainda esclarecer se existe afinidade entre moléculas de determinados herbicidas com as proteínas da superfície interna dos plasmodesmos, o que poderia facilitar o transporte desses herbicidas pela manipulação do Tamanho Limite de Exclusão do plasmodesmo, independentemente do tamanho da molécula, bem como determinar se a semelhança com algum composto natural da planta promove maior taxa de transporte simplástico. Pouca importância tem sido dada à participação dos plasmodesmos no transporte de herbicidas sistêmicos. No entanto, o avanço dos trabalhos com produtos marcados e a intensificação das pesquisas em fisiologia vegetal para melhor entendimento dos processos referentes à absorção, translocação, conjugação e/ou degradação de herbicidas podem esclarecer muitos aspectos ainda não definidos do transporte de herbicidas via xilema e floema e sua associação com o apoplasto e domínios simplásticos.Plasmodesmata are plasma channels connecting neighboring cells and allowing the exchange of informational, functional and structural molecules and xenobiotics among cells of the same

  2. Investigation of 1-cm dose equivalent for photons behind shielding materials

    International Nuclear Information System (INIS)

    Hirayama, Hideo; Tanaka, Shun-ichi

    1991-03-01

    The ambient dose equivalent at 1-cm depth, assumed equivalent to the 1-cm dose equivalent in practical dose estimations behind shielding slabs of water, concrete, iron or lead for normally incident photons having various energies was calculated by using conversion factors for a slab phantom. It was compared with the 1-cm depth dose calculated with the Monte Carlo code EGS4. It was concluded from this comparison that the ambient dose equivalent calculated by using the conversion factors for the ICRU sphere could be used for the evaluation of the 1-cm dose equivalent for the sphere phantom within 20% errors. Average and practical conversion factors are defined as the conversion factors from exposure to ambient dose equivalent in a finite slab or an infinite one, respectively. They were calculated with EGS4 and the discrete ordinates code PALLAS. The exposure calculated with simple estimation procedures such as point kernel methods can be easily converted to ambient dose equivalent by using these conversion factors. The maximum value between 1 and 30 mfp can be adopted as the conversion factor which depends only on material and incident photon energy. This gives the ambient dose equivalent on the safe side. 13 refs., 7 figs., 2 tabs

  3. Simple Kidney Cysts

    Science.gov (United States)

    ... Solitary Kidney Your Kidneys & How They Work Simple Kidney Cysts What are simple kidney cysts? Simple kidney cysts are abnormal, fluid-filled ... that form in the kidneys. What are the kidneys and what do they do? The kidneys are ...

  4. Calcium carbonate as a possible dosimeter for high irradiation doses

    International Nuclear Information System (INIS)

    Negron M, A.; Ramos B, S.; Camargo R, C.; Uribe, R. M.; Gomez V, V.; Kobayashi, K.

    2014-08-01

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  5. Calcium carbonate as a possible dosimeter for high irradiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Negron M, A.; Ramos B, S.; Camargo R, C. [UNAM, Instituto de Ciencias Nucleares, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Uribe, R. M. [Kent State University, College of Technology, Kent OH (United States); Gomez V, V. [UNAM, Instituto de Quimica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Kobayashi, K., E-mail: negron@nucleares.unam.mx [Yokohama National University (Japan)

    2014-08-15

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  6. Simultaneous hole scattering in a biased simple barrier

    Directory of Open Access Journals (Sweden)

    L. Diago-Cisneros

    2013-01-01

    Full Text Available Se desarrolla un estudio teórico de la propagación de flujos de huecos (pesad os/ligeros a través de una heteroestructura de barrera simple de materiales semiconductores III - V, considerando una perturbación externa. En los cálculos, usando la Aproximación Dispersiva Multicomponente, se incluyó la interacción con un campo eléctrico externo paralelo a la dirección de propagación – perpendicular a las intercaras – y se estudiaron las las magnitudes relevantes del transporte cuántico de huecos – transmisión, conductancia y tiempo de fase. Este form a lismo nos permitió considerar simultán eamente todos los canales propagantes. Para el sistema de la barrera simple, se estudió la dependencia de la conductancia con el campo aplicado a través de los diferentes canales de huecos. Igualmente, se analizó cómo el aumento del in - plane momentum κ T afecta los resultados, lo cuál nos brinda una idea de cómo el acoplamiento entre bandas influencia la transmisión con un voltaje aplicado. Adicionalmente, fijando diferentes valores de la mezcla interbanda, se hizo un breve estudio del tiempo de transmi sión de la fase como función del voltaje aplicado en la heteroestructura. Nuestros resultados fueron exitósamente comparados con algunos comportamientos obtenidos previamente en el tunelaje de huecos a través de heteroestructuras semiconductoras usando dif erentes aproximaciones.

  7. A dose to curie conversion methodology

    International Nuclear Information System (INIS)

    Stowe, P.A.

    1987-01-01

    Development of the computer code RadCAT (Radioactive waste Classification And Tracking) has led to the development of a simple dose rate to curie content conversion methodology for containers with internally distributed radioactive material. It was determined early on that, if possible, the computerized dose rate to curie evaluation model employed in RadCAT should yield the same results as the hand method utilized and specified in plant procedures. A review of current industry practices indicated two distinct types of computational methodologies are presently in use. The most common methods are computer based calculations utilizing complex mathematical models specifically established for various containers geometries. This type of evaluation is tedious, however, and does not lend itself to repetition by hand. The second method of evaluation, therefore, is simplified expressions that sacrifice accuracy for ease of computation, and generally over estimate container curie content. To meet the aforementioned criterion current computer based models were deemed unacceptably complex and hand computational methods to be too inaccurate for serious consideration. The contact dose rate/curie content analysis methodology presented herein provides an equation that is easy to use in hand calculations yet provides accuracy equivalent to other computer based computations

  8. Correlação entre os teores de líber e fibras em caules de crotalária e malva Correlation between bast and fiber content in sunn hemp and malva stalks

    Directory of Open Access Journals (Sweden)

    Anísio Azzini

    1986-01-01

    Full Text Available No presente estudo, estimou-se a correlação entre os teores de líber (casca e fibras em caules de crotalária (Crotalaria juncea L. e malva (Urena lobata L., com o objetivo de estabelecer um procedimento simples e rápido de análise de fibra. Os resultados obtidos mostraram que os teores de líber e fibra estão relacionados entre si, com alto nível de significância (p > 0,99 para as correlações entre essas duas características tecnológicas. Os coeficientes de correlação observados, de 0,84 e 0,79, respectivamente, para crotalária e malva, permitem a avaliação indireta do teor de fibra liberiana através do teor de líber, estabelecendo um procedimento simples e rápido de análise de fibra, a ser utilizado especificamente em programas de melhoramento genético.In this paper it was estimated the correlation between the bast and fiber contents in suns hemp (Crotalaria juncea L. and malva (Urena lobata L. stalks. The results showed that fiber contents are related with a high level of signification (p > 0.99 for the correlation between these two technological characteristics. The correlation coefficients observed were of 0.84 and 0.79, respectively to sunn hemp and malva. These high levels of correlation showed that the fiber content may be evaluated indirectly through the bast content, establishing a simple and rapid procedure for fiber determination of both species.

  9. Single-dose radiotherapy for painful bone metastases

    International Nuclear Information System (INIS)

    Kal, H.B.

    1999-01-01

    Background: External beam radiotherapy is frequently applied for palliative treatment of painful bone lesions with a variety of fractionation schemes. There is a continuous interest to administer only 1 or a few dose fractions for inducing pain relief. Methods: A review of the literature was made with the aim to determine whether a treatment can be deduced that is simple and effective. The linear-quadratic (L-Q) concept was applied to compare reported therapy schemes which each other for the iso-effect pain relief. Results: Single-dose and fractionated radiotherapy resulted in partial or complete pain relief in about 80% of the patients. Complete responses have been observed in about 43% of the patients. For patients responding to treatment, the duration of pain relief is at least 3 to 4 months with reported duration of up to 1 year or even longer. Conclusion: Based on this review of literature data concerning randomized trials a treatment with a single dose of 8 Gy is effective for inducing pain relief. (orig.) [de

  10. La tasa de variación del PIB en un modelo simple de determinación de la renta || The Variation of GDP in a Simple Model of Income Determination

    Directory of Open Access Journals (Sweden)

    Escartin, Eduardo

    2017-06-01

    Full Text Available En este artículo se demuestra que en un modelo simple de determinación de la renta, cuando se tienen en cuenta funciones de consumo lineales, la tasa de variación del producto interior bruto (PIB es igual al cociente entre el incremento de la inversión y la suma del consumo exógeno más la inversión inicial. Esto significa que la pendiente de la función de consumo no influye en la tasa de variación del PIB y que lo relevante para esa tasa de variación es el consumo exógeno y la inversión inicial. || In this paper, we prove that in a simple model of income determination, when taking into account linear functions, the change rate for the gross domestic product (GDP is equal to the quotient of the increase in investment and the sum of exogenous consumption plus the initial investment. This means that the slope of the consumption function does not influence the change rate for the GDP and what matters for this variation rate is the exogenous consumption and the initial investment.

  11. Relación entre el aporte fiscal directo, la calidad del cuerpo docente y la producción científica de las instituciones pertenecientes al Consejo de Rectores de las universidades chilenas

    Directory of Open Access Journals (Sweden)

    Paulina Manríquez Maulén

    2015-03-01

    Full Text Available La búsqueda del conocimiento como uno de los principales focos que tienen las universidades se encuentra estrechamente relacionada con la calidad docente. Materializar este concepto implica establecer una relación entre la producción científica en Chile, la calidad docente y el Aporte Fiscal Directo (AFD que es destinado a las universidades pertenecientes al CRUCH, éste es el objetivo de esta investigación. Para el análisis, primero se busca determinar si existe correlación entre las variables de estudio. Posteriormente, se obtiene el índice de correlación simple entre las mismas. Los resultados muestran una correlación muy alta entre cada una de las variables. Además, se realiza este mismo procedimiento segmentando a las universidades según su ubicación, en la Región Metropolitana o en regiones y si son estatales o no, obteniendo resultados similares. De forma complementaria, se realiza un análisis con la técnica de regresión lineal simple en donde se obtiene que sólo un pequeño porcentaje de las publicaciones científicas provenientes de las instituciones pertenecientes el CRUCH estarían siendo publicadas por otro tipo de investigadores. The pursuit of knowledge as one of the main focuses of universities is closely related to quality. To materialize this concept in establishing the relationship of scienti­fic production in Chile, quality of faculty and Direct Fiscal Funding (AFD destinated to universities belonging to the CRUCH, is the aim of this research. For analysis, a scatter plot is created to intuitively determine if there is a correlation between the study variables. Subsequently, the rate of simple correlation is obtained between the same variables, which results in a very high correlation between each one of the variables. In addition, this same procedure is performed after segmenting universities by location, in the metropolitan area or other regions, and by being state-owned or not, obtaining similar results

  12. Radiation dose to testes and risk of infertility from radiotherapy for rectal cancer.

    Science.gov (United States)

    Mazonakis, Michalis; Damilakis, John; Varveris, Haris; Gourtsouiannis, Nicholas

    2006-03-01

    This study aims to provide the means for testicular dose estimation from radiotherapy for rectal cancer. Rectal irradiation was simulated on a humanoid phantom using a 6 MV photon beam. The effect of field size, distance from irradiated area, wedge introduction into lateral beams, tissue thickness along the beam axis and use of gonad shields on the testicular dose was examined. Testicular dose was measured in five patients undergoing radiotherapy for rectal carcinoma. For a 4500 cGy tumour dose, testicular dose was 32-216 cGy depending upon the field dimensions and the distance from the field isocenter. The presence of wedges increased the testicular dose by a factor up to 2.2. The increase of irradiated tissue thickness increased the gonadal dose up to 40% whereas the use of the appropriate gonad shield reduced the dose by >66%. A simple method was developed to estimate testicular dose. The mean difference between the in vivo gonadal doses and the doses calculated using the proposed method was 5.8%. Testicular dose can exceed the value of 100 cGy, which permits a complete recovery of spermatogenesis. The presented data can be used to estimate the gonadal dose and the associated risk of infertility attributable to rectal irradiation.

  13. Some effects of random dose measurement errors on analysis of atomic bomb survivor data

    International Nuclear Information System (INIS)

    Gilbert, E.S.

    1985-01-01

    The effects of random dose measurement errors on analyses of atomic bomb survivor data are described and quantified for several procedures. It is found that the ways in which measurement error is most likely to mislead are through downward bias in the estimated regression coefficients and through distortion of the shape of the dose-response curve. The magnitude of the bias with simple linear regression is evaluated for several dose treatments including the use of grouped and ungrouped data, analyses with and without truncation at 600 rad, and analyses which exclude doses exceeding 200 rad. Limited calculations have also been made for maximum likelihood estimation based on Poisson regression. 16 refs., 6 tabs

  14. Valor nutritivo do capim Piatã adubado com diferentes doses de biofertilizante

    Directory of Open Access Journals (Sweden)

    Marco Antonio Previdelli Orrico Junior

    2013-07-01

    Full Text Available Objetivou-se com este estudo verificar a influência das diferentes doses de biofertilizantes gerados a partir dos dejetos de bovinos e suínos em fase de terminação sobre valor nutritivo do capim Piatã. O experimento foi conduzido em casa de vegetação em delineamento inteiramente casualizado em esquema fatorial com parcela subdividida no tempo. As parcelas foram compostas por oito tratamentos: dois tipos de biofertilizantes em quatro doses, já as subparcelas pelos quatro diferentes períodos de cortes. Os biofertilizantes foram aplicados em dose única, após o corte de uniformização, nas doses de 0, 100, 200 e 300 kg ha-1 de N. Não foi observada diferença significativa entre os tipos de biofertilizantes e na interação biofertilizante x dose, o que possibilita a recomendação do uso de ambos os biofertilizantes, sem que ocorra prejuízo na qualidade das plantas avaliadas. Os teores de fibra em detergente neutro, fibra em detergente ácido, celulose, hemicelulose e lignina apresentaram comportamento linear negativo em função das doses crescentes de nitrogênio. Já os teores proteína bruta e digestibilidade “in vitro” da matéria seca responderam linear e positivamente às doses de nitrogênio. Também foi observado efeito dos períodos de corte, uma vez que as plantas produzidas no verão apresentaram valor nutritivo superior às de outono.

  15. Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams

    International Nuclear Information System (INIS)

    Kuenzler, Thomas; Fotina, Irina; Stock, Markus; Georg, Dietmar

    2009-01-01

    The dosimetric performance of a Monte Carlo algorithm as implemented in a commercial treatment planning system (iPlan, BrainLAB) was investigated. After commissioning and basic beam data tests in homogenous phantoms, a variety of single regular beams and clinical field arrangements were tested in heterogeneous conditions (conformal therapy, arc therapy and intensity-modulated radiotherapy including simultaneous integrated boosts). More specifically, a cork phantom containing a concave-shaped target was designed to challenge the Monte Carlo algorithm in more complex treatment cases. All test irradiations were performed on an Elekta linac providing 6, 10 and 18 MV photon beams. Absolute and relative dose measurements were performed with ion chambers and near tissue equivalent radiochromic films which were placed within a transverse plane of the cork phantom. For simple fields, a 1D gamma (γ) procedure with a 2% dose difference and a 2 mm distance to agreement (DTA) was applied to depth dose curves, as well as to inplane and crossplane profiles. The average gamma value was 0.21 for all energies of simple test cases. For depth dose curves in asymmetric beams similar gamma results as for symmetric beams were obtained. Simple regular fields showed excellent absolute dosimetric agreement to measurement values with a dose difference of 0.1% ± 0.9% (1 standard deviation) at the dose prescription point. A more detailed analysis at tissue interfaces revealed dose discrepancies of 2.9% for an 18 MV energy 10 x 10 cm 2 field at the first density interface from tissue to lung equivalent material. Small fields (2 x 2 cm 2 ) have their largest discrepancy in the re-build-up at the second interface (from lung to tissue equivalent material), with a local dose difference of about 9% and a DTA of 1.1 mm for 18 MV. Conformal field arrangements, arc therapy, as well as IMRT beams and simultaneous integrated boosts were in good agreement with absolute dose measurements in the

  16. Comparison of the two different standard flux-to-dose rate conversion factors

    International Nuclear Information System (INIS)

    Metghalchi, M.; Ashrafi, R.

    1983-01-01

    A very useful and simple way of obtaining the dose rate associated with neutron or photon fluxes is to multiply these fluxes by the appropriate flux-to-dose rate conversion factors. Two basic standard flux-to-dose rate conversion factors. are being used in all over the world, those recommended by the International Commission on Radiation Protection (ICRP) and the American National Standars (ANS). The purpose of this paper is to compare these two standard with each other. The comparison proved that the dose rate associated with a specific neutron flux, obtained by the ANS flux-to-dose rate conversion factors is usually higher than those calculated by the ICRP's conversion factors. Whereas in the case of the photon, in all energies, the difference between the dose rates obtained by these two standard flux-to-dose rate conversion factors are noticeable, and the ANS results are higher than the ICRP ones. So, it should be noted that for a specific neutron or photon flux the dose rate obtained by the ANS flux-to-dose rate conversion factors are more conservative than those obtained by the ICRP's. Therefore, in order to establish a more reasonable new standard flux-to-dose rate conversion factors, more work should be done. (author)

  17. Trends in x-ray photography and patient exposure dose

    International Nuclear Information System (INIS)

    Orito, Takeo; Sanada, Shigeru; Maekawa, Ryuichi; Koshida, Kichiro; Hiraki, Tatsunosuke

    1980-01-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired. (J.P.N.)

  18. Measurement of ambient dose equivalent H*(10) and directional dose equivalent H'(0.07) with pocket sized survey meters

    International Nuclear Information System (INIS)

    Iwatschenko, Michael

    2008-01-01

    Full text: In many parts of the world, predominantly in Europe, small sized survey meters based on Geiger-Mueller or proportional counters are widely used for dose rate and dose equivalent rate measurements, while in other regions, especially in the U.S., ionisation chambers are preferred for this task. This paper tries to shed some light on the likely reasons for these two diverging instrumental inclinations. Their respective strengths and weaknesses is analyzed in respect to energy response, dose rate measuring range, size, weight and susceptibility to environmental influences. Furthermore the response and limitations regarding the measurement of pulsed radiation (medical X-ray and CT-devices, accelerators, non-destructive testing) is discussed. A newly developed pocket size instrument based on a pan-cake Geiger-Mueller tube is used as an example to explain the capability and flexibility of modern survey meters. The RadEye B20 is a compact multi-purpose dose rate meter and contamination meter for alpha, beta, gamma and X-ray radiation. By virtue of carefully designed multi-layer gamma energy filters, H*(10) (deep dose) or H'(0,07) (shallow dose) measurements from 17 - 1300 keV can be performed. The instrument can even be worn in a belt holster, so that the impact to the mobility of the user is minimized. For emergency response purposes alpha and beta contamination can be discriminated using another optional filter; a simple sample changer adapter can extend the scope of application. Immediate and reproducible counter measurements, e.g. of smear tests can be performed locally. (author)

  19. Crescimento de lactentes não-anêmicos suplementados com diferentes doses profiláticas de ferro Growth in non-anemic infants supplemented with different prophylactic iron doses

    Directory of Open Access Journals (Sweden)

    Danielle G. da Silva

    2008-08-01

    Full Text Available OBJETIVO: Comparar os efeitos de diferentes doses profiláticas de ferro sobre o crescimento e estado nutricional de lactentes não-anêmicos. MÉTODOS: Estudo do tipo prospectivo e randomizado. Lactentes de 5,0 a 6,9 meses de vida que atenderam aos critérios de inclusão e apresentaram hemoglobina capilar ≥ 11 g/dL foram alocados randomicamente em três grupos com doses profiláticas de suplemento de ferro (sulfato ferroso de 1 mg/kg/dia (n = 39, 2 mg/kg/dia (n = 36 e 25 mg/semana (n = 39. A suplementação durou 16 semanas. Foram avaliados peso e comprimento. O estado nutricional foi avaliado por meio dos escores z do peso/idade, comprimento/idade e peso/comprimento com base na referência da Organização Mundial da Saúde (2006. Os dados de morbidade foram obtidos durante as visitas mensais. RESULTADOS: Antes da suplementação, os grupos apresentaram similar estado nutricional. Não houve diferença entre os grupos na ingestão diária de nutrientes. Durante o estudo, o ganho de peso, o ganho de comprimento e os incrementos nos índices antropométricos não diferiram estatisticamente entre os grupos suplementados. A ocorrência e duração dos episódios de morbidade não diferiram estatisticamente entre os grupos. De modo geral, observaram-se melhorias nos índices peso/idade e peso/comprimento na população estudada, porém o comprimento/idade não apresentou diferenças antes e após a suplementação. CONCLUSÃO: As diferentes doses profiláticas de ferro não exerceram efeito diferenciado sobre o crescimento e estado nutricional dos lactentes não-anêmicos.OBJECTIVE: To compare the effects of different prophylactic iron doses on the growth and nutritional status of non-anemic infants. METHODS: Prospective randomized study. Infants aged 5.0 to 6.9 months who met the inclusion criteria and showed capillary hemoglobin ≥ 11 g/dL were randomly allocated into three groups who received the following prophylactic doses of iron

  20. Development of an effective dose coefficient database using a computational human phantom and Monte Carlo simulations to evaluate exposure dose for the usage of NORM-added consumer products.

    Science.gov (United States)

    Yoo, Do Hyeon; Shin, Wook-Geun; Lee, Jaekook; Yeom, Yeon Soo; Kim, Chan Hyeong; Chang, Byung-Uck; Min, Chul Hee

    2017-11-01

    After the Fukushima accident in Japan, the Korean Government implemented the "Act on Protective Action Guidelines Against Radiation in the Natural Environment" to regulate unnecessary radiation exposure to the public. However, despite the law which came into effect in July 2012, an appropriate method to evaluate the equivalent and effective doses from naturally occurring radioactive material (NORM) in consumer products is not available. The aim of the present study is to develop and validate an effective dose coefficient database enabling the simple and correct evaluation of the effective dose due to the usage of NORM-added consumer products. To construct the database, we used a skin source method with a computational human phantom and Monte Carlo (MC) simulation. For the validation, the effective dose was compared between the database using interpolation method and the original MC method. Our result showed a similar equivalent dose across the 26 organs and a corresponding average dose between the database and the MC calculations of database with sufficient accuracy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Iodine versus thyroxine in treatment of simple goiter in sudan

    International Nuclear Information System (INIS)

    Hassan, A.M; Khangi, F.A; Ali, N.I.; Besheir, S.O.; Eltom, M.A.

    2003-01-01

    This study was designed to update the existing information concening goiter prevalence and iodine deficiency disorders in omdurman city and to compare the effects of thyroxine versus iodine in the treament of simlpe goiter. Thyroxine in different doses is commonly used in treatment of simple goiter in Sudan. The goiter survey was conducted in Omdurman secondary school for girls (Khartoum state). Of the goitrous subjects 99 girls were selected to participate in the treament protocol. A control group of 54 non-goitrous subjects from the same school were also included. The goitrous subjects were divided randomly into two groups receiving either daily dose of 100 μg thyroxine for six months or a single dose of 400 mg of oral iodine in the form of iodized oil. Blood and urine samples were collected from the goitrous and control group and recollected from the goitrous subjects every six weeks for six months. Goiter size was assessed at 3,6 and 14 months after the commencement of the treament. Blood samples were analyzed for serum level of T4,T3 and TSH using sensitive radioimmunoassay techniques. Urine samples were analyzed for urinary iodine excretion. Goiter was found in 139 students out of 1034, (13.4%). They were all euthyroid with simple diffuse goiter.T4 in the goitrous group (93.3±26.9 nmole /L (mean±SD)) was significanty lower than in the control group (106.4±18.2nmole/L,p<0.05). T3 was significantly higher in the goitrous (1.6±0.4 nmole/L) than in the control group (1.3±0.3 nmole/L,p<0.05) while there was no significant difference in the mean serum TSH or urinary iodine excretion between the two groups. More than 70% of the goitrous and the control subjects excreted 2 μg 1 / dI or less. Of the subjects treated with thyroxine 87.8% showed complete disappearance or definite regression of the goiter size compared with 90% of those received iodine after the treament.(Author) =

  2. Iodine versus thyroxine in treatment of simple goiter in sudan

    International Nuclear Information System (INIS)

    Eltom, M.A.; Ali, N.

    2003-01-01

    This study was designed to update the existing information concerning goiter prevalence and iodine deficiency disorders in Omdurman city and to compare the effects of thyroxine versus iodine in the treatment of simple goiter. Thyroxine in different doses is commonly used in treatment of sample goiter in sudan. This goiter survey was conducted in Omdurman secondary school for girls (Khartoum state). Of the goitrous subjects 99 girls were selected to participate in the treatment protocol. A control group of 54 non-goitrous subjects from the same school were also included. This goitrous subjects were divided randomly into two groups receiving either daily dose of 100 μg thyroxine for six months or a single dose of 400 mg of oral iodine in the form iodized oil. Blood and urine samples were collected from the goitrous and control group and recollected from the goitrous subjects every six weeks for six months. Goiter size was assessed at 3,6 and 14 months after the commencement of the treatment. Blood samples were analyzed for serum level of T4, T3 and TSH using sensitive radioimmunoassay techniques. Urine samples were analyzed for urinary iodine excretion. Goiter was found in 139 students out of 1034, (13.4%). They were all euthyroid with simple diffuse goiter. T4 in the goitrous group (93.3±26.9 n mole/L (mean±SD)) was significantly lower than in the control group (106.4±18.2 n mole /L, p<0.05). T3 was significantly higher in the goitrous (1.3 ±0.3 n mole/L, p<0.05) while there was no significant difference in the mean serum TSH or urinary iodine excretion between the two groups. More than 70% of goitrous and the control subjects excreted 2 μg I /dl or less. Of the subjects treated with thyroxine 87.8% showed complete disappearance or definite regression of the goiter sized compared with 90% of those received iodine after the treatment

  3. Is simple nephrectomy truly simple? Comparison with the radical alternative.

    Science.gov (United States)

    Connolly, S S; O'Brien, M Frank; Kunni, I M; Phelan, E; Conroy, R; Thornhill, J A; Grainger, R

    2011-03-01

    The Oxford English dictionary defines the term "simple" as "easily done" and "uncomplicated". We tested the validity of this terminology in relation to open nephrectomy surgery. Retrospective review of 215 patients undergoing open, simple (n = 89) or radical (n = 126) nephrectomy in a single university-affiliated institution between 1998 and 2002. Operative time (OT), estimated blood loss (EBL), operative complications (OC) and length of stay in hospital (LOS) were analysed. Statistical analysis employed Fisher's exact test and Stata Release 8.2. Simple nephrectomy was associated with shorter OT (mean 126 vs. 144 min; p = 0.002), reduced EBL (mean 729 vs. 859 cc; p = 0.472), lower OC (9 vs. 17%; 0.087), and more brief LOS (mean 6 vs. 8 days; p < 0.001). All parameters suggest favourable outcome for the simple nephrectomy group, supporting the use of this terminology. This implies "simple" nephrectomies are truly easier to perform with less complication than their radical counterpart.

  4. Measuring pacemaker dose: A clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Xiao Ying; Harrison, Amy S. [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2012-07-01

    Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose while at the same time not requiring a significant investment in time to maintain an efficient workflow in the clinic. The dosimeters analyzed here were ion chambers, diodes, metal-oxide-semiconductor field effect transistor (MOSFETs), and optically stimulated luminescence (OSL) dosimeters. A simple phantom was used to quantify the angular and energy dependence of each dosimeter. Next, 8 patients plans were delivered to a Rando phantom with all the dosimeters located where the pacemaker would be, and the measurements were compared with the predicted dose. A cone beam computed tomography (CBCT) image was obtained to determine the dosimeter response in the kilovoltage energy range. In terms of the angular and energy dependence of the dosimeters, the ion chamber and diode were the most stable. For the clinical cases, all the dosimeters match relatively well with the predicted dose, although the ideal dosimeter to use is case dependent. The dosimeters, especially the MOSFETS, tend to be less accurate for the plans, with many lateral beams. Because of their efficiency, we recommend using a MOSFET or a diode to measure the dose. If a discrepancy is observed between the measured and expected dose (especially when the pacemaker to field edge is <10 cm), we recommend analyzing the treatment plan to see whether there are many lateral beams. Follow-up with another dosimeter rather than repeating multiple times with the same type of dosimeter. All dosimeters should be placed after the CBCT has been acquired.

  5. A new method to assess the gonadal doses in women during radiation treatment

    International Nuclear Information System (INIS)

    Agrawal, M.S.; Pant, G.C.

    1977-01-01

    The relative inaccessibility of the ovaries renders direct measurement of the gonadal doses difficult. A relatively simple method is described to tackle this problem - using the upper margin of the public symphysis as a reference point. Measurement of Radiation doses were done in a Masonite human phantom using T.L.D. and a Co-60 teletherapy unit. The accompanying figures document the observations made. The distance between the lower edge of the treatment port and the reference point is denoted by 'd'. First figure relates observed ratios of the radiation doses at the ovary and the reference point to 'd' for various port sizes and the second figure shows the relationship between the area of the port and the dose ratio (ovary: reference-point) for various values of 'd'. The advantage of this documentation is that it serves as a 'Ready Reckoner' to assess the ovarian doses under different treatment situations-once the doses at the reference point is measured

  6. Mutation frequencies in male mice and the estimation of genetic hazards of radiation in men: (specific-locus mutations/dose-rate effect/doubling dose/risk estimation)

    International Nuclear Information System (INIS)

    Russell, W.L.; Kelly, E.M.

    1982-01-01

    Estimation of the genetic hazards of ionizing radiation in men is based largely on the frequency of transmitted specific-locus mutations induced in mouse spermatogonial stem cells at low radiation dose rates. The publication of new data on this subject has permitted a fresh review of all the information available. The data continue to show no discrepancy from the interpretation that, although mutation frequency decreases markedly as dose rate is decreased from 90 to 0.8 R/min (1 R = 2.6 X 10 -4 coulombs/kg) there seems to be no further change below 0.8 R/min over the range from that dose rate to 0.0007 R/min. Simple mathematical models are used to compute: (a) a maximum likelihood estimate of the induced mutation frequency at the low dose rates, and (b) a maximum likelihood estimate of the ratio of this to the mutation frequency at high dose rates in the range of 72 to 90 R/min. In the application of these results to the estimation of genetic hazards of radiation in man, the former value can be used to calculate a doubling dose - i.e., the dose of radiation that induces a mutation frequency equal to the spontaneous frequency. The doubling dose based on the low-dose-rate data compiled here is 110 R. The ratio of the mutation frequency at low dose rate to that at high dose rate is useful when it becomes necessary to extrapolate from experimental determinations, or from human data, at high dose rates to the expected risk at low dose rates. The ratio derived from the present analysis is 0.33

  7. Radiation doses to patients in radiodiagnostic in five Spanish hospitals. First results

    International Nuclear Information System (INIS)

    Grupo Aula Salinas

    1995-01-01

    We present the first results obtained from a study of radiation doses received by patients in diagnostic radiology in real examinations performed with a transmission camera. The study is being carried out in several Spanish hospitals and their dependent specialist outpatient centres where a quality control programme is being applied. The hospitals have over 4,600 beds and attend a population of over 2 million. The dose-area product was measured and the patient surface dose was calculated from it. Median values are presented for both parameters for a number of simple frequently-performed explorations. For most of these, the reference surface-dose values recommended by the C.E.C. are available. Although the corresponding assessment of image quality has not yet been performed, the results indicate that recommendations are generally being satisfied. However, the lack of correlation in the variation of the two values leads us to conclude that use of a single parameter to indicate the dose received by patients is inadequate. 4 refs

  8. a simple a simple excitation control excitation control excitation

    African Journals Online (AJOL)

    eobe

    field voltages determined follow a simple quadratic relationship that offer a very simple control scheme, dependent on only the stator current. Keywords: saturated reactances, no-load field voltage, excitation control, synchronous generators. 1. Introduction. Introduction. Introduction. The commonest generator in use today is ...

  9. USO DE TABACO ENTRE ADOLESCENTES: REVISÃO DE LITERATURA

    OpenAIRE

    Amanda Márcia dos Santos Reinaldo; Camila Cesar Goecking; Jennifer Perucci de Almeida; Yasmin Narciso Goulart

    2010-01-01

    Revisión sistemática de la literatura sobre el uso de tabaco entre adolescentes. La utilización del tabaco entre adolescentes, en general, puede estar asociada al éxito, a la necesidad de aceptación, a cuestiones familiares, entre otros factores que incentivan de cierta forma a su uso. Las políticas de salud para el área trabajan para prevenir y reducir el consumo, alertando en relación al riesgo al que tal población se expone cuando utiliza tabaco. Conocer el perfil de los adolescentes que u...

  10. Dose specification for radiation therapy: dose to water or dose to medium?

    International Nuclear Information System (INIS)

    Ma, C-M; Li Jinsheng

    2011-01-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  11. Development of a Simple Dipstick Assay for Operational Monitoring of DDT.

    Science.gov (United States)

    Ismail, Hanafy M; Kumar, Vijay; Singh, Rudra P; Williams, Christopher; Shivam, Pushkar; Ghosh, Ayan; Deb, Rinki; Foster, Geraldine M; Hemingway, Janet; Coleman, Michael; Coleman, Marlize; Das, Pradeep; Paine, Mark J I

    2016-01-01

    Indoor residual spraying (IRS) of DDT is used to control visceral leishmaniasis (VL) in India. However, the quality of spraying is severely compromised by a lack of affordable field assays to monitor target doses of insecticide. Our aim was to develop a simple DDT insecticide quantification kit (IQK) for monitoring DDT levels in an operational setting. DDT quantification was based on the stoichiometric release of chloride from DDT by alkaline hydrolysis and detection of the released ion using Quantab chloride detection strips. The assay was specific for insecticidal p,p`-DDT (LoQ = 0.082 g/m2). Bostik discs were effective in post spray wall sampling, extracting 25-70% of active ingredient depending on surface. Residual DDT was sampled from walls in Bihar state in India using Bostik adhesive discs and DDT concentrations (g p,p`-DDT/m2) were determined using IQK and HPLC (n = 1964 field samples). Analysis of 161 Bostik samples (pooled sample pairs) by IQK and HPLC produced excellent correlation (R2 = 0.96; Bland-Altman bias = -0.0038). IQK analysis of the remaining field samples matched HPLC data in identifying households that had been under sprayed, in range or over sprayed. A simple dipstick assay has been developed for monitoring DDT spraying that gives comparable results to HPLC. By making laboratory-based analysis of DDT dosing accessible to field operatives, routine monitoring of DDT levels can be promoted in low- and middle- income countries to maximise the effectiveness of IRS.

  12. Relação entre ansiedade, depressão e desesperança entre grupos de idosos Relación entre ansiedad, depresión y desesperanza entre grupos de ancianos Relations between anxiety, depression and hopelessness among elderly groups

    Directory of Open Access Journals (Sweden)

    Katya Luciane de Oliveira

    2006-08-01

    Full Text Available O envelhecimento é uma etapa da vida que permanece pouco conhecida e estudada, se comparada a outras fases do desenvolvimento humano. Nesta pesquisa buscou-se explorar a relação entre ansiedade, depressão e desesperança entre grupos de idosos. Participaram deste estudo 79 idosos provenientes de centro do terceira idade de um posto de retirada de medicamentos e de uma instituição asilar. Utilizou-se um questionário para os dados de caracterização dos idosos, bem como as escalas Beck para mensurar sintomas de ansiedade, depressão e desesperança. Os resultados evidenciaram relação estatisticamente significativa entre ansiedade, depressão e desesperança nos idosos. O grupo de asilares apresentou uma maior incidência de sintomas ansiosos, depressivos e desesperançosos em relação aos outros dois grupos.El envejecimiento es una etapa de la vida que permanece poco conocida o estudiada, al ser comparada a otras fases del desarrollo humano. Esta investigación buscó explorar la relación entre ansiedad, depresión y desesperanza entre grupos de ancianos. Participaron en este estudio 79 adultos mayores provenientes de tres sitios diferentes: un centro de tercera edad, un puesto de retirada de medicinas y un asilo. Un cuestionario para los datos de caracterización de los ancianos fue utilizado, así como las escalas Beck para mensurar síntomas de ansiedad, depresión y desesperanza. Los resultados dejaron en evidencia relación estadísticamente significativa entre dichos síntomas en los adultos mayores. El grupo proveniente del asilo presentó mayor incidencia de manifestaciones en relación con los demás grupos.Aging is a life stage that remains hardly ever studied and, consequently, unknown if compared to other human development phases. This research investigates the relation between anxiety, depression and hopelessness among elderly groups. 79 elderly people, from three different units, such as a 'third-age-center', a center of

  13. Field study to evaluate radiation doses in dental practices

    International Nuclear Information System (INIS)

    Panzer, W.; Scheurer, C.

    1984-05-01

    An inexpensive and simple test device was developed and used in a field study to evaluate entrance dose, dose to an intra-oral film, filtration and field size under routine conditions in more than 150 dental practices. The test device consists of two films of different speed and a set of 5 thin copper filters for a filter analytical determination of the radiation quality. Dentists voluntarily participating in the study were asked to expose the test device like they usually do when examining a molar tooth. The main result was the evidence of a significant dose reduction compared to the findings of similar studies performed in 1970 and 1976. This reduction is due to a general shift to lower values and a complete disappearance of values above 45 mGy (5 R) which in 1970 were still more than 15%. In the same way the number of facilities showing insufficient filtration or collimation had decreased. Nevertheless, a large spread of dose values could still be observed, ranging from less than 0.45 mGy (50 mR) to more than 26 mGy (3 R), for the entrance dose. The most striking result, however, was that such an important parameter like the speed of the films used at the respective unit turned out to have no impact on the entrance dose. (orig./HP)

  14. Patient doses from x-ray examinations in Sweden - follow-up of remedial actions

    International Nuclear Information System (INIS)

    Joensson, Helene; Leitz, W.

    2002-03-01

    In early 1999 the Swedish Radiation Protection Authority (SSI) requested data about patient doses etc. for a number of specified x-ray examinations. The aim was on one hand to get a basis for planned regulations on diagnostic reference levels (DRL) and on the other hand to obtain an overview of how the situation is in the country with respect to patient doses. The licensees who reported dose values exceeding (provisional) DRL were asked to perform investigations about the grounds for the high dose and to take remedial actions for reducing the dose. In this report the outcome is presented. The dose reductions were large: on average between 35 and 60 % for the various examinations. A large proportion of the measures taken were simple and cheap, such as increase of radiation quality, improved examination methodology (smaller radiation fields, use of compression, reduced number of images or fluoroscopy time) and optimising the film processing. This is indicating that the planned regulations on diagnostic reference levels have a good chance to succeed with a large reduction of the patient doses in Sweden

  15. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F.

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients. PMID:26820986

  16. Is patient size important in dose determination and optimization in cardiology?

    International Nuclear Information System (INIS)

    Reay, J; Chapple, C L; Kotre, C J

    2003-01-01

    Patient dose determination and optimization have become more topical in recent years with the implementation of the Medical Exposures Directive into national legislation, the Ionising Radiation (Medical Exposure) Regulations. This legislation incorporates a requirement for new equipment to provide a means of displaying a measure of patient exposure and introduces the concept of diagnostic reference levels. It is normally assumed that patient dose is governed largely by patient size; however, in cardiology, where procedures are often very complex, the significance of patient size is less well understood. This study considers over 9000 cardiology procedures, undertaken throughout the north of England, and investigates the relationship between patient size and dose. It uses simple linear regression to calculate both correlation coefficients and significance levels for data sorted by both room and individual clinician for the four most common examinations, left ventrical and/or coronary angiography, single vessel stent insertion and single vessel angioplasty. This paper concludes that the correlation between patient size and dose is weak for the procedures considered. It also illustrates the use of an existing method for removing the effect of patient size from dose survey data. This allows typical doses and, therefore, reference levels to be defined for the purposes of dose optimization

  17. Review of techniques and detectors used in instruments for field measurement of beta doses and dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1983-01-01

    Generally, field measurements are required to assess the hazard from #betta#-rays before personnel are allowed to occupy a working space or perform a task. Occasionally, the measurements are required for an assessment after a #betta#-ray exposure is suspected to have occurred. Until recently the dose or dose rate have been the quantities of interest but there is now felt to be a need to characterize the energies and directions of the #betta#-rays as well. The purpose of #betta#-dosimetry is the assessment of hazard to superficial tissues (within approx. 10 mm of the surface) and that these tissues may also be exposed simultaneously to other ionizing radiations. The #betta#-dosimetry technique must take account of this. With these uses of field instruments in mind the following detectors, and associated techniques will be discussed in terms of the measurement principles, advantages and limitations: thin-walled ion chambers (sometimes in combination with thick-walled ones or with covers thick enough to prevent penetration of #betta#-particles); thin scintillators, nearly tissue equivalent, to provide a detector analogous to skin; scintillators, thick enough to absorb all the energy of the #betta#-particles (circuitry is required to count pulses according to size to permit calculation of dose or dose rate); silicon diodes with thin detection layers operated as photocurrent generators; silicon diodes, reversed biassed, with pulses counted according to size; and simple pulse counters (e.g., GM counters or silicon diodes with thin windows)

  18. Mathematical phantoms for evaluation of age-specific internal dose

    International Nuclear Information System (INIS)

    Cristy, M.

    1980-01-01

    A series of mathematical phantoms representing children has been developed for use with photon transport codes. These phantoms, patterned after the Fisher-Snyder adult phantom, consist of simple mathematical expressions for the boundaries of the major organs and body sections. The location and shape of the organs are consistent with drawings depicting developmental anatomy, with the organ volumes assigned such that the masses at the various ages conform closely with the data presented in Reference Man. The explicit mathematical expressions for the various ages overcome the potential misrepresentation of organ sizes that occurred in phantoms derived from simple mathematical transformations of the adult phantom. Female breast tissue has been added to the phantoms, including the adult, now allowing assessment of doses to this organ

  19. Floridablanca entre la modernidad y la posmodernidad

    OpenAIRE

    Senatore, María Ximena

    2007-01-01

    Este artículo se centra en los diálogos entre el pasado y el presente creados en el marco de la modernidad y de la posmodernidad. La arqueología como práctica social puede ser entendida como un diálogo pasado-presente. Floridablanca es una historia, un sitio, una experiencia, una idea, una utopía. Es también un punto de encuentro entre modernidad y posmodernidad. El objetivo de este trabajo es presentar ciertas reflexiones sobre los diálogos pasado-presente que crean, transforman y reproducen...

  20. Simple optical readout for ethanol-chlorobenzene dosimetry system

    International Nuclear Information System (INIS)

    Ilijas, B.; Razem, D.

    1999-01-01

    Optical readout of the ethanol-chlorobenzene (ECB) or Dvornik dosimetry system is based on the development of the coloured secondary complex of ferric thiocyanate which has a maximum absorption at 485 nm. The applicability of a rugged, hand-held, battery powered filter colorimeter operating at 480 nm has been investigated as a reader for this purpose. This simple reader performs very well within absorbance one displaying an excellent linearity of absorbance with the concentration of Cl - ions. It is shown that by choosing the appropriate dilution factor when preparing the secondary complex solution the entire useful dose range of the dosimeter up to 2 MGy can be covered. The applicability of this reader to some other liquid chemical dosimeters is also discussed. (author)

  1. Simple optical readout for ethanol - chlorobenzene dosimetry system

    International Nuclear Information System (INIS)

    Ilijas, B.; Razem, D.

    1999-01-01

    Optical readout of the ethanol-chlorobenzene (ECB or Dvornik dosimetry system) is based on the development of coloured secondary complex of ferric thiocyanate which has a maximum absorption at 485 nm. The applicability of a rugged, hand-held, battery powered filter colorimeter operating at 480 nm has been investigated as a reader for this purpose. This simple reader performs very well within absorbance displaying an excellent linearity of absorbance with the concentration of Cl - ions. It was shown, by choosing the appropriate dilution factor when preparing the secondary complex solution, the entire useful dose range of the dosimeter up to 2 MGy can be covered. The applicability of the same reader to some other liquid chemical dosimeters is also discussed. (author)

  2. Efeito de doses de paclobutrazol na cultura do alho

    Directory of Open Access Journals (Sweden)

    Resende Geraldo Milanez de

    2002-01-01

    Full Text Available O trabalho foi realizado no período de maio a outubro de 1991 no campo experimental do setor de olericultura da Ufla, Lavras, MG, com o objetivo de avaliar a influência de doses de paclobutrazol sobre o controle do pseudoperfilhamento e nas características morfológicas e comerciais do alho (Allium sativum L.. Utilizou-se o delineamento experimental de blocos ao acaso, com quatro doses de paclobutrazol (0, 500, 1.000 e 1.500 mg de i.a. L-1, em cinco repetições. Com o aumento das concentrações de paclobutrazol, houve uma redução na altura das plantas e no número de folhas por planta aos 60 e 90 dias após o plantio. A produtividade total e comercial de bulbos apresentou efeito significativo em relação às doses de paclobutrazol, sendo as concentrações de 725 e 778 mg L-1 as que proporcionaram as maiores produtividades. A porcentagem de bulbos pseudoperfilhados evidenciou efeito quadrático com o incremento das doses de paclobutrazol, cuja concentração de 1.163 mg L-1 propiciou maior redução na porcentagem de pseudoperfilhamento. A concentração de 744 mg L-1 de paclobutrazol proporcionou o maior peso médio de bulbo; e em relação a número de bulbilhos por bulbo, não se verificaram diferenças significativas entre os tratamentos.

  3. Therapeutic dose from a pyroelectric electron accelerator.

    Science.gov (United States)

    Fullem, T Z; Fazel, K C; Geuther, J A; Danon, Y

    2009-11-01

    Simple heating of pyroelectric crystals has been used as the basis for compact sources of X rays, electrons, ions and neutrons. We report on the evaluation of the feasibility of using a portable pyroelectric electron accelerator to deliver a therapeutic dose to tissue. Such a device could be mass produced as a handheld, battery-powered instrument. Experiments were conducted with several crystal sizes in which the crystal was heated inside a vacuum chamber and the emitted electrons were allowed to penetrate a thin beryllium window into the surrounding air. A Faraday cup was used to count the number of electrons that exited the window. The energy of these electrons was determined by measuring the energy spectrum of the X rays that resulted from the electron interactions with the Faraday cup. Based on these measurements, the dose that this source could deliver to tissue was calculated using Monte Carlo calculations. It was found that 10(13) electrons with a peak energy of the order of 100 keV were emitted from the beryllium window and could deliver a dose of 1664 Gy to a 2-cm-diameter, 110-microm-deep region of tissue located 1.5 cm from the window with air between the window and the tissue. This dose level is high enough to consider this technology for medical applications in which shallow energy deposition is beneficial.

  4. Implications of dose limit modification for radioactive installations dedicated to research

    International Nuclear Information System (INIS)

    Lumbreras, J.M.; Fernandez, G.M.; Marana, D.

    1992-01-01

    The reduced dose limits proposed in the ICRP recommendations affect the Spanish Regulations on Sanitary Protection against Ionizing Radiation. Some implications of this for radioactive installations dedicated to research are pointed out. A very simple statistical study shows that dosimetric data might be used to adopt new criteria for classification of personnel, and even of working areas. (author)

  5. Chromosomal Aberrations in Normal and AT Cells Exposed to High Dose of Low Dose Rate Irradiation

    Science.gov (United States)

    Kawata, T.; Shigematsu, N.; Kawaguchi, O.; Liu, C.; Furusawa, Y.; Hirayama, R.; George, K.; Cucinotta, F.

    2011-01-01

    Ataxia telangiectasia (A-T) is a human autosomally recessive syndrome characterized by cerebellar ataxia, telangiectases, immune dysfunction, and genomic instability, and high rate of cancer incidence. A-T cell lines are abnormally sensitive to agents that induce DNA double strand breaks, including ionizing radiation. The diverse clinical features in individuals affected by A-T and the complex cellular phenotypes are all linked to the functional inactivation of a single gene (AT mutated). It is well known that cells deficient in ATM show increased yields of both simple and complex chromosomal aberrations after high-dose-rate irradiation, but, less is known on how cells respond to low-dose-rate irradiation. It has been shown that AT cells contain a large number of unrejoined breaks after both low-dose-rate irradiation and high-dose-rate irradiation, however sensitivity for chromosomal aberrations at low-dose-rate are less often studied. To study how AT cells respond to low-dose-rate irradiation, we exposed confluent normal and AT fibroblast cells to up to 3 Gy of gamma-irradiation at a dose rate of 0.5 Gy/day and analyzed chromosomal aberrations in G0 using fusion PCC (Premature Chromosomal Condensation) technique. Giemsa staining showed that 1 Gy induces around 0.36 unrejoined fragments per cell in normal cells and around 1.35 fragments in AT cells, whereas 3Gy induces around 0.65 fragments in normal cells and around 3.3 fragments in AT cells. This result indicates that AT cells can rejoin breaks less effectively in G0 phase of the cell cycle? compared to normal cells. We also analyzed chromosomal exchanges in normal and AT cells after exposure to 3 Gy of low-dose-rate rays using a combination of G0 PCC and FISH techniques. Misrejoining was detected in the AT cells only? When cells irradiated with 3 Gy were subcultured and G2 chromosomal aberrations were analyzed using calyculin-A induced PCC technique, the yield of unrejoined breaks decreased in both normal and AT

  6. Construction of voxel head phantom and application to BNCT dose calculation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Sik; Lee, Choon Ik; Lee, Jai Ki [Hanyang Univ., Seoul (Korea, Republic of)

    2001-06-15

    Voxel head phantom for overcoming the limitation of mathematical phantom in depicting anatomical details was constructed and example dose calculation for BNCT was performed. The repeated structure algorithm of the general purpose Monte Carlo code, MCNP4B was applied for voxel Monte Carlo calculation. Simple binary voxel phantom and combinatorial geometry phantom composed of two materials were constructed for validating the voxel Monte Carlo calculation system. The tomographic images of VHP man provided by NLM(National Library of Medicine) were segmented and indexed to construct voxel head phantom. Comparison od doses for broad parallel gamma and neutron beams in AP and PA directions showed decrease of brain dose due to the attenuation of neutron in eye balls in case of voxel head phantom. The spherical tumor volume with diameter, 5cm was defined in the center of brain for BNCT dose calculation in which accurate 3 dimensional dose calculation is essential. As a result of BNCT dose calculation for downward neutron beam of 10keV and 40keV, the tumor dose is about doubled when boron concentration ratio between the tumor to the normal tissue is 30{mu}g/g to 3 {mu}g/g. This study established the voxel Monte Carlo calculation system and suggested the feasibility of precise dose calculation in therapeutic radiology.

  7. Generation of Composite Dose and Biological Effective Dose (BED) Over Multiple Treatment Modalities and Multistage Planning Using Deformable Image Registration

    International Nuclear Information System (INIS)

    Zhang, Geoffrey; Huang, T-C; Feygelman, Vladimir; Stevens, Craig; Forster, Kenneth

    2010-01-01

    Currently there are no commercially available tools to generate composite plans across different treatment modalities and/or different planning image sets. Without a composite plan, it may be difficult to perform a meaningful dosimetric evaluation of the overall treatment course. In this paper, we introduce a method to generate composite biological effective dose (BED) plans over multiple radiotherapy treatment modalities and/or multistage plans, using deformable image registration. Two cases were used to demonstrate the method. Case I was prostate cancer treated with intensity-modulated radiation therapy (IMRT) and a permanent seed implant. Case II involved lung cancer treated with two treatment plans generated on two separate computed tomography image sets. Thin-plate spline or optical flow methods were used as appropriate to generate deformation matrices. The deformation matrices were then applied to the dose matrices and the resulting physical doses were converted to BED and added to yield the composite plan. Cell proliferation and sublethal repair were considered in the BED calculations. The difference in BED between normal tissues and tumor volumes was accounted for by using different BED models, α/β values, and cell potential doubling times. The method to generate composite BED plans presented in this paper provides information not available with the traditional simple dose summation or physical dose summation. With the understanding of limitations and uncertainties of the algorithms involved, it may be valuable for the overall treatment plan evaluation.

  8. Assessing Doses to Interventional Radiologists Using a Personal Dosimeter Worn Over a Protective Apron

    Energy Technology Data Exchange (ETDEWEB)

    Stranden, E.; Widmark, A.; Sekse, T. (Buskerud Univ. College, Drammen (Norway))

    2008-05-15

    Background: Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. Purpose: To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Material and Methods: Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Results: Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. Conclusion: A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron

  9. Assessing Doses to Interventional Radiologists Using a Personal Dosimeter Worn Over a Protective Apron

    International Nuclear Information System (INIS)

    Stranden, E.; Widmark, A.; Sekse, T.

    2008-01-01

    Background: Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. Purpose: To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Material and Methods: Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Results: Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. Conclusion: A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron

  10. A Monte Carlo model for mean glandular dose evaluation in spot compression mammography.

    Science.gov (United States)

    Sarno, Antonio; Dance, David R; van Engen, Ruben E; Young, Kenneth C; Russo, Paolo; Di Lillo, Francesca; Mettivier, Giovanni; Bliznakova, Kristina; Fei, Baowei; Sechopoulos, Ioannis

    2017-07-01

    To characterize the dependence of normalized glandular dose (DgN) on various breast model and image acquisition parameters during spot compression mammography and other partial breast irradiation conditions, and evaluate alternative previously proposed dose-related metrics for this breast imaging modality. Using Monte Carlo simulations with both simple homogeneous breast models and patient-specific breasts, three different dose-related metrics for spot compression mammography were compared: the standard DgN, the normalized glandular dose to only the directly irradiated portion of the breast (DgNv), and the DgN obtained by the product of the DgN for full field irradiation and the ratio of the mid-height area of the irradiated breast to the entire breast area (DgN M ). How these metrics vary with field-of-view size, spot area thickness, x-ray energy, spot area and position, breast shape and size, and system geometry was characterized for the simple breast model and a comparison of the simple model results to those with patient-specific breasts was also performed. The DgN in spot compression mammography can vary considerably with breast area. However, the difference in breast thickness between the spot compressed area and the uncompressed area does not introduce a variation in DgN. As long as the spot compressed area is completely within the breast area and only the compressed breast portion is directly irradiated, its position and size does not introduce a variation in DgN for the homogeneous breast model. As expected, DgN is lower than DgNv for all partial breast irradiation areas, especially when considering spot compression areas within the clinically used range. DgN M underestimates DgN by 6.7% for a W/Rh spectrum at 28 kVp and for a 9 × 9 cm 2 compression paddle. As part of the development of a new breast dosimetry model, a task undertaken by the American Association of Physicists in Medicine and the European Federation of Organizations of Medical Physics

  11. Estudo comparativo da analgesia entre bupivacaína e morfina intra-articular em osteoartrite de joelho Estudio comparativo de la analgesia entre bupivacaína y morfina intra-articular en osteoartritis de la rodilla Intra-articular bupivacaine and morphine for knee osteoarthritis analgesia. Comparative study

    Directory of Open Access Journals (Sweden)

    Miriam C B Gazi

    2005-10-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A osteoartrite é a mais freqüente entre as doenças articulares em pessoas idosas. O objetivo do estudo foi comparar o efeito analgésico da bupivacaína e da morfina por via intra-articular em pacientes portadores de osteoartrite de joelho. MÉTODO: Foram avaliados 39 pacientes em estudo duplamente encoberto, divididos de forma aleatória, em dois grupos: os do G1 (n = 18 receberam 1 mg (1 mL de morfina diluída em 9 mL de solução fisiológica a 0,9% e os do G2 (n = 21, 25 mg (10 mL de bupivacaína a 0,25% sem vasoconstritor, por via intra-articular. A intensidade da dor foi avaliada pela escala numérica e verbal nos momentos 0, 30, 60 minutos e 7 dias, em repouso e em movimento. Foram avaliados a necessidade de complementação analgésica com paracetamol (500 mg, a dose total de analgésico utilizado, a duração da analgesia e a qualidade da analgesia (pelo paciente. RESULTADOS: Dos 39 pacientes, 31 completaram o estudo. Não houve diferença significativa da intensidade da dor em repouso e em movimento entre os dois grupos nos momentos estudados. Não houve diferença entre os dois grupos no tempo entre a administração da solução e a necessidade de complementação analgésica. A dose média do paracetamol utilizada no primeiro dia da semana foi de 796 mg do G1 e de 950 mg no G2; a complementação na semana foi de 3578 mg no G1 e 5333 mg no G2. CONCLUSÕES: O efeito analgésico de 1 mg de morfina e de 25 mg de bupivacaína a 0,25% sem vasoconstritor intra-articular foram semelhantes.JUSTIFICATIVA Y OBJETIVOS: La osteoartritis es la más frecuente entre las enfermedades articulares en personas de edad. El objetivo del estudio fue comparar el efecto analgésico de la bupivacaína y de la morfina por vía intra-articular en pacientes portadores de osteoartritis de rodilla. MÉTODO: Fueron evaluados 39 pacientes en estudio doblemente encubierto, divididos de forma aleatoria, en dos grupos: los del G1 (n = 18

  12. DIVERSIDAD GENÉTICA ENTRE SUBPOBLACIONES RACIALES BOVINAS DE COSTA RICA

    Directory of Open Access Journals (Sweden)

    Marco Martínez

    2015-01-01

    Full Text Available El objetivo del estudio fue cuantificar la diversidad genética entre 16 subpoblaciones raciales bovinas de Costa Rica, con base en 1412 muestras de ADN bovino de todo el país, evaluadas mediante 18 marcadores microsatélites. El número promedio de alelos (Na por locus dentro de raza fue de 10,3, que varían entre 8 (Holstein×Jersey y 13 (Criolla para doble propósito. El número promedio de alelos efectivo (Ne fue de 5,04, con cambios entre 4,18 (Jersey y 5,64 (Bos taurus×Bos indicus. La heterocigosidad observada promedio fue de 0,77, variando entre 0,73 (Jersey y 0,81 (Bos taurus×Bos indicus. La heterocigosidad esperada (He promedio fue de 0,78, que oscilan entre 0,74 (Jersey y Holstein×Jersey y 0,81 (Bos taurus×Bos indicus, Criolla para doble propósito y Cruces para doble propósito. El contenido de información polimórfica (PIC fue de 0,76, con variaciones entre 0,71 (Jersey y Holstein×Jersey y 0,79 (Criollas para doble propósito y Cruces para doble propósito. El FIS promedio fue de 0,02, con oscilaciones entre -0,03 (Holstein×Jersey a 0,04 (Brahman, Criolla para carne y Cruces para leche. La desviación del equilibrio Hardy Weinberg no fue significativa (p>0,05 en la mayoría de los loci para las subpoblaciones raciales. El subgrupo con mayor número de loci en desequilibrio fue Jersey (8 loci, mientras que los subgrupos Bos taurus×Bos indicus, Criolla para leche y Holstein×Jersey presentaron solo 1 locus en desequilibrio. Los índices de fijación FIS (0,02, FIT (0,05 y FST (0,03 indicaron cierta tendencia hacia la homocigosidad. Los dendrogramas mostraron 3 agrupaciones raciales claramente diferenciadas que coinciden con las razas de origen Bos taurus, Bos indicus y sus respectivos cruces. Los resultados del análisis indicaron que el número de microsatélites empleados sí permitió establecer una discriminación clara a nivel de las frecuencias alélicas y en la distribución del tamaño de los alelos entre las

  13. Comportamento da alface americana em função do uso de doses e épocas de aplicação de boro em cultivo de inverno Behavior of crisp head lettuce as a result of doses and application times of boron in winter crop

    Directory of Open Access Journals (Sweden)

    Jony E. Yuri

    2004-09-01

    Full Text Available Avaliou-se a influência de doses de bórax sobre o rendimento e qualidade pós-colheita da alface americana (Lactuca sativa L., em três ensaios distintos conduzidos de junho a agosto/2002, no município de Três Pontas (MG. Utilizou-se o delineamento de blocos ao acaso com cinco doses de bórax (0,00; 0,75; 1,50; 2,25 e 3,00 kg ha-1 e quatro repetições, aplicadas em três diferentes épocas via foliar (14; 21 e 28 dias após o transplantio. A massa fresca total apresentou efeito quadrático no qual a dose de 1,58 kg ha-1 de bórax resultou em maior rendimento. Verificou-se variação de 795 a 829 g planta-1 entre as épocas de aplicação, sem diferirem estatisticamente entre si. A aplicação de 1,71 kg ha-1 de bórax possibilitou a obtenção de maior massa fresca comercial. O melhor resultado (563 g planta-1 foi obtido na aplicação aos 21 dias. Esta data também contribuiu na obtenção de maior circunferência da cabeça (41,7 cm, sendo significativamente superior à aplicação aos 28 dias (40,6 cm. Não foram observados efeitos significativos para o comprimento de caule entre os tratamentos. A dose de 1,55 kg ha-1 de bórax proporcionou uma melhor conservação da alface mantida durante 20 dias em câmara-fria.The influence of doses of borax on yield and post harvest quality of crisp head lettuce (Lactuca sativa L. was evaluated. Three distinct trials were conducted in Tres Pontas, Minas Gerais State, Brazil, from June to August 2002. The randomized block design with five doses of borax (0.00; 0.75; 1.50; 2.25 and 3.00 kg.ha-1 and four replicates, applied foliarly at different times (14; 21 and 28 days after transplanting was evaluated. The total fresh matter presented a quadratic effect, where the dose of 1.58 kg ha-1 of borax resulted in a greater yield. A range of 795 to 829 g plant-1 between different application times, with no statistical significant differences was observed. The application of 1.71 kg ha-1 of borax resulted in

  14. Relación entre el consumo de drogas y maltrato infantil entre estudiantes universitarios de la universidad en Colombia

    Directory of Open Access Journals (Sweden)

    Monica Rosaura Garcia Baquero

    2015-01-01

    Full Text Available Esta investigación examina la relación entre el uso de drogas en estudiantes de una Universidad Pública en Villavicencio, Colombia, y su relación con el maltrato durante la niñez, utilizando como referente teórico la perspectiva bioecológica. Estudio exploratorio retrospectivo, con una muestra de 313 estudiantes de pregrado. El 10.2% de los encuestados refiere haber sido maltratado en la Infancia y la violencia de mayor uso fue la violencia física seguida de la violencia psicológica. El 56.9% de las estudiantes encuestados han consumido sustancias psicoactivas en algún momento de la vida, y su inicio entre los 13 y los 18 años. Se evidencia maltrato en la infancia con manifestaciones de agresiones físicas, al igual que el consumo de sustancias psicoactivas, pero no se observa una relación estadísticamente significativa entre maltrato durante la infancia y el consumo de sustancias psicoactivas en la muestra estudiada.

  15. Effects of pyruvate dose on in vivo metabolism and quantification of hyperpolarized 13C spectra

    DEFF Research Database (Denmark)

    Janich, M. A.; Menzel, M. I.; Wiesinger, F.

    2012-01-01

    Real‐time in vivo measurements of metabolites are performed by signal enhancement of [1‐13C]pyruvate using dynamic nuclear polarization, rapid dissolution and intravenous injection, acquisition of free induction decay signals and subsequent quantification of spectra. The commonly injected dose...... uptake and metabolic conversion. The goal of this study was to examine the effects of a [1‐13C]pyruvate bolus on metabolic conversion in vivo. Spectra were quantified by three different methods: frequency‐domain fitting with LCModel, time‐domain fitting with AMARES and simple linear least‐squares fitting...... in the time domain. Since the simple linear least‐squares approach showed bleeding artifacts and LCModel produced noisier time signals. AMARES performed best in the quantification of in vivo hyperpolarized pyruvate spectra. We examined pyruvate doses of 0.1–0.4 mmol/kg (body mass) in male Wistar rats...

  16. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. SU-F-J-217: Accurate Dose Volume Parameters Calculation for Revealing Rectum Dose-Toxicity Effect Using Deformable Registration in Cervical Cancer Brachytherapy: A Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Zhen, X; Chen, H; Liao, Y; Zhou, L [Southern Medical University, Guangzhou, Guangdong (China); Hrycushko, B; Albuquerque, K; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: To study the feasibility of employing deformable registration methods for accurate rectum dose volume parameters calculation and their potentials in revealing rectum dose-toxicity between complication and non-complication cervical cancer patients with brachytherapy treatment. Method and Materials: Data from 60 patients treated with BT including planning images, treatment plans, and follow-up clinical exam were retrospectively collected. Among them, 12 patients complained about hematochezia were further examined with colonoscopy and scored as Grade 1–3 complication (CP). Meanwhile, another 12 non-complication (NCP) patients were selected as a reference group. To seek for potential gains in rectum toxicity prediction when fractional anatomical deformations are account for, the rectum dose volume parameters D0.1/1/2cc of the selected patients were retrospectively computed by three different approaches: the simple “worstcase scenario” (WS) addition method, an intensity-based deformable image registration (DIR) algorithm-Demons, and a more accurate, recent developed local topology preserved non-rigid point matching algorithm (TOP). Statistical significance of the differences between rectum doses of the CP group and the NCP group were tested by a two-tailed t-test and results were considered to be statistically significant if p < 0.05. Results: For the D0.1cc, no statistical differences are found between the CP and NCP group in all three methods. For the D1cc, dose difference is not detected by the WS method, however, statistical differences between the two groups are observed by both Demons and TOP, and more evident in TOP. For the D2cc, the CP and NCP cases are statistically significance of the difference for all three methods but more pronounced with TOP. Conclusion: In this study, we calculated the rectum D0.1/1/2cc by simple WS addition and two DIR methods and seek for gains in rectum toxicity prediction. The results favor the claim that accurate dose

  18. Entre Madres: Talleres de Comunicación

    OpenAIRE

    Cardoso Moreno, María Jesús; Aragonés, Lucía Tomás

    2015-01-01

    En el presente artículo se expone el trabajo de investigación cuyo objetivo fue conocer el grado de satisfacción de las madres con un taller de formación denominado "Entremadres". Las 150 mujeres madres que participaron en el taller en la ciudad de Zaragoza, España, se conformaron en un grupo de 7 u 8 madres y estuvo compuesto por seis sesiones de dos horas cada una, entre los años 2008 y 2013. Este taller fue dirigido a madres con hijos de edades comprendidas entre 2 y 16 años. La frecuencia...

  19. Recovery and permanent radiation damage of plastic scintillators at different dose rates

    International Nuclear Information System (INIS)

    Bicken, B.; Holm, U.; Marckmann, T.; Wick, K.; Rhode, M.

    1990-01-01

    This paper reports on the radiation stability of plastic scintillators and wavelength shifters for the calorimeter of the ZEUS detector by irradiating them with protons, a 60 Co-source, and depleted uranium. Changes in light yield, absorption length and absorption coefficient have been measured for storage in inert and oxygen atmospheres during and after irradiation. Radiation doses up to 40 kGy with dose rates of 30 up to 2000 Gy/h have been applied. The polystyrene based scintillator SCSN-38 and the wavelength shifters Y-7 and K-27 in PMMA show an additional absorption but a recovery in air to a low permanent damage (at 10 kGy) which is proportional to the applied dose. Series investigations on samples of all production cycles of the ZEUS scintillators with high dose rates show only minor differences in radiation hardness. The recovery is described by a simple oxygen diffusion model for high and medium dose rates down to 30 Gy/h. During long term irradiations at low dose rates (<100 Gy/h) of 3 mm thick SCSN-38 in air the radiation damage recovers to a permanent damage which does not depend on the dose rate. On the other hand the radiation damage at very low dose rates (17 Gy/a) seems to be higher than expected for the accumulated dose

  20. Crossing simple resonances

    International Nuclear Information System (INIS)

    Collins, T.

    1985-08-01

    A simple criterion governs the beam distortion and/or loss of protons on a fast resonance crossing. Results from numerical integrations are illustrated for simple sextupole, octupole, and 10-pole resonances

  1. Crossing simple resonances

    Energy Technology Data Exchange (ETDEWEB)

    Collins, T.

    1985-08-01

    A simple criterion governs the beam distortion and/or loss of protons on a fast resonance crossing. Results from numerical integrations are illustrated for simple sextupole, octupole, and 10-pole resonances.

  2. Feasibility of online IMPT adaptation using fast, automatic and robust dose restoration

    Science.gov (United States)

    Bernatowicz, Kinga; Geets, Xavier; Barragan, Ana; Janssens, Guillaume; Souris, Kevin; Sterpin, Edmond

    2018-04-01

    Intensity-modulated proton therapy (IMPT) offers excellent dose conformity and healthy tissue sparing, but it can be substantially compromised in the presence of anatomical changes. A major dosimetric effect is caused by density changes, which alter the planned proton range in the patient. Three different methods, which automatically restore an IMPT plan dose on a daily CT image were implemented and compared: (1) simple dose restoration (DR) using optimization objectives of the initial plan, (2) voxel-wise dose restoration (vDR), and (3) isodose volume dose restoration (iDR). Dose restorations were calculated for three different clinical cases, selected to test different capabilities of the restoration methods: large range adaptation, complex dose distributions and robust re-optimization. All dose restorations were obtained in less than 5 min, without manual adjustments of the optimization settings. The evaluation of initial plans on repeated CTs showed large dose distortions, which were substantially reduced after restoration. In general, all dose restoration methods improved DVH-based scores in propagated target volumes and OARs. Analysis of local dose differences showed that, although all dose restorations performed similarly in high dose regions, iDR restored the initial dose with higher precision and accuracy in the whole patient anatomy. Median dose errors decreased from 13.55 Gy in distorted plan to 9.75 Gy (vDR), 6.2 Gy (DR) and 4.3 Gy (iDR). High quality dose restoration is essential to minimize or eventually by-pass the physician approval of the restored plan, as long as dose stability can be assumed. Motion (as well as setup and range uncertainties) can be taken into account by including robust optimization in the dose restoration. Restoring clinically-approved dose distribution on repeated CTs does not require new ROI segmentation and is compatible with an online adaptive workflow.

  3. Calibration and intercomparison methods of dose calibrators used in nuclear medicine facilities; Metodos de calibracao e de intercomparacao de calibradores de dose utilizados em servicos de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Alessandro Martins da

    1999-07-01

    Dose calibrators are used in most of the nuclear medicine facilities to determine the amount of radioactivity administered to a patient in a particular investigation or therapeutic procedure. It is therefore of vital importance that the equipment used presents good performance and is regular;y calibrated at a authorized laboratory. This occurs of adequate quality assurance procedures are carried out. Such quality control tests should be performed daily, other biannually or yearly, testing, for example, its accuracy and precision, the reproducibility and response linearity. In this work a commercial dose calibrator was calibrated with solution of radionuclides used in nuclear medicine. Simple instrument tests, such as response linearity and the response variation of the source volume increase at a constant source activity concentration, were performed. This instrument can now be used as a working standard for calibration of other dose calibrators/ An intercomparison procedure was proposed as a method of quality control of dose calibrators used in nuclear medicine facilities. (author)

  4. A simple method for the rapid assessment of the qualitative ESR response of fossil samples to laboratory irradiation

    International Nuclear Information System (INIS)

    Gruen, Rainer

    2006-01-01

    A simple and effective method is proposed for the analysis of the qualitative response of ESR spectra to dosing. The method comprises of the alignment of the spectra, and subtraction of the natural spectrum from those that were subsequently irradiated in the laboratory. In that way, the ESR response to environmental radiation can be compared to the ESR response to laboratory radiation. As illustrated on some tooth enamel and mollusk shell samples, both materials are frequently used in dating and accident dosimetry, the method is very effective for the identification of regions where the two radiation regimes generate qualitatively the same dose response as well as for the isolation of radiation insensitive signals that interfere with those used for dose estimation

  5. Application of the luminescence single-aliquot technique for dose estimation in the Marmara Sea

    International Nuclear Information System (INIS)

    Tanir, Guenes; Sencan, Emine; Boeluekdemir, M. Hicabi; Tuerkoez, M. Burak; Tel, Eyuep

    2005-01-01

    The aim of this study is to obtain the equivalent dose, which is the important quantity for all the studies related to the use of luminescence in dating sediments. Recent advances in luminescence dating have led to increasing application of the technique to sediment from the depositional environmental samples. The sample used in this study is the active main fault sample that was collected from the Sea of Marmara in NW Turkey. Equivalent dose was measured using both the multiple-aliquots and the single-aliquot techniques. In this study single aliquot regeneration on additive dose (SARA) procedure was also used. The result obtained was not in agreement with the results evaluated from the multiple-aliquots procedure. So a simple modification was suggested for SARA procedure. In our modified procedure the calculated dose (D) values were obtained by using the additive dose protocol instead of regeneration protocol

  6. Diálogo entre el islamismo y occidente

    Directory of Open Access Journals (Sweden)

    Ana María MARTÍN GÓMEZ

    2011-05-01

    Full Text Available Este artículo analiza uno de los fenómenos más actuales de nuestras sociedades pluralistas y multiculturales: el encuentro entre la civilización occidental y la islámica. La elaboración de esta nota crítica se ha llevado a cabo tras la lectura de tres libros fundamentales acerca de esta temática: Un paseo por el laberinto. Sobre política y religión en el diálogo entre civilizaciones, de José María García Gómez-Heras, Laicismo, agnosticismo y fundamentalismo de Antonio García-Santesmases, y El islamismo contra el Islam. Las claves para entender el terrorismo yihadista, de Gustavo de Arístegui. A partir de estos tres ensayos, se ha emprendido un estudio filosófico de la situación actual entre el islamismo y Occidente.

  7. A model for radiological dose assessment in an urban environment

    International Nuclear Information System (INIS)

    Hwang, Won Tae; Kim, Eun Han; Jeong, Hyo Joon; Suh, Kyung Suk; Han, Moon Hee

    2007-01-01

    A model for radiological dose assessment in an urban environment, METRO-K has been developed. Characteristics of the model are as follows ; 1) mathematical structures are simple (i.e. simplified input parameters) and easy to understand due to get the results by analytical methods using experimental and empirical data, 2) complex urban environment can easily be made up using only 5 types of basic surfaces, 3) various remediation measures can be applied to different surfaces by evaluating the exposure doses contributing from each contamination surface. Exposure doses contributing from each contamination surface at a particular location of a receptor were evaluated using the data library of kerma values as a function of gamma energy and contamination surface. A kerma data library was prepared for 7 representative types of Korean urban building by extending those data given for 4 representative types of European urban buildings. Initial input data are daily radionuclide concentration in air and precipitation, and fraction of chemical type. Final outputs are absorbed dose rate in air contributing from the basic surfaces as a function of time following a radionuclide deposition, and exposure dose rate contributing from various surfaces constituting the urban environment at a particular location of a receptor. As the result of a contaminative scenario for an apartment built-up area, exposure dose rates show a distinct difference for surrounding environment as well as locations of a receptor

  8. Radiation doses and risks from internal emitters

    International Nuclear Information System (INIS)

    Harrison, John; Day, Philip

    2008-01-01

    This review updates material prepared for the UK Government Committee Examining Radiation Risks from Internal Emitters (CERRIE) and also refers to the new recommendations of the International Commission on Radiological Protection (ICRP) and other recent developments. Two conclusions from CERRIE were that ICRP should clarify and elaborate its advice on the use of its dose quantities, equivalent and effective dose, and that more attention should be paid to uncertainties in dose and risk estimates and their implications. The new ICRP recommendations provide explanations of the calculation and intended purpose of the protection quantities, but further advice on their use would be helpful. The new recommendations refer to the importance of understanding uncertainties in estimates of dose and risk, although methods for doing this are not suggested. Dose coefficients (Sv per Bq intake) for the inhalation or ingestion of radionuclides are published as reference values without uncertainty. The primary purpose of equivalent and effective dose is to enable the summation of doses from different radionuclides and from external sources for comparison with dose limits, constraints and reference levels that relate to stochastic risks of whole-body radiation exposure. Doses are calculated using defined biokinetic and dosimetric models, including reference anatomical data for the organs and tissues of the human body. Radiation weighting factors are used to adjust for the different effectiveness of different radiation types, per unit absorbed dose (Gy), in causing stochastic effects at low doses and dose rates. Tissue weighting factors are used to take account of the contribution of individual organs and tissues to overall detriment from cancer and hereditary effects, providing a simple set of rounded values chosen on the basis of age- and sex-averaged values of relative detriment. While the definition of absorbed dose has the scientific rigour required of a basic physical quantity

  9. Simple unification

    International Nuclear Information System (INIS)

    Ponce, W.A.; Zepeda, A.

    1987-08-01

    We present the results obtained from our systematic search of a simple Lie group that unifies weak and electromagnetic interactions in a single truly unified theory. We work with fractionally charged quarks, and allow for particles and antiparticles to belong to the same irreducible representation. We found that models based on SU(6), SU(7), SU(8) and SU(10) are viable candidates for simple unification. (author). 23 refs

  10. Reduction of fields between co-axial cylinders by means of interposed screens; L'abaissement des champs entre cylindres coaxiaux au moyen d'ecrans intercales

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, J; Bruck, H; Prevot, F

    1950-05-01

    The dielectric rigidity of the space between two coaxial cylinders at a given potential can be increased by interposing coaxial cylindrical screens (the method of C. M. Turner, Thesis, Univ. of Wisconsin, 1943). The combination of screens reducing the maximum value of a simple field between two cylinders is calculated as a function of number of screens, their radius, and their potential, and, for a given number of screens, the optimum radii and potentials for maximum field reduction are determined. [French] La rigidite dielectrique de l'espace compris entre deux cylindres coaxiaux, portes a des potentiels donnes, peut etre augmentee en intercalant des ecrans cylindriques coaxiaux (methode de C.M. Turner). En fonction de leur nombre, de leur rayon et de leur potentiel, on calcule de combien ces ecrans permettent de reduire la valeur du champ regnant primitivement entre les deux cylindres, et, pour un nombre d'ecrans donne, on determine les valeurs optima de leur rayon et potentiel, correspondant a la reduction maximum des champs. (auteur)

  11. The association between smoking and tuberculosis La asociación entre tabaquismo y tuberculosis

    Directory of Open Access Journals (Sweden)

    K.M. Hassmiller

    2006-01-01

    Full Text Available OBJECTIVE: To review epidemiological evidence on the association between smoking and tuberculosis. METHODS: Reviewed articles were identified by searching Pubmed for the terms "smoking" or "tobacco" and "tuberculosis". Additional articles were obtained from the bibliographies of identified papers. RESULTS: Thirty-four studies were reviewed: five investigate the association between smoking and mortality from tuberculosis, 13 investigate the association between smoking and development of tuberculosis, eigth investigate the association between smoking and infection with Mycobacterium tuberculosis, and nine estimate the impact of smoking on characteristics of tuberculosis and disease outcomes. CONCLUSIONS: Taken together, evidence suggests that smoking (both current and former is associated with: risk of being infected with Mycobacterium tuberculosis, risk of developing tuberculosis, development of more severe forms of tuberculosis, and risk of dying of tuberculosis. In many cases, there is a strong dose-response relationship -both in terms of quantity and duration of smoking. These relationships are not explained away by controlling for potentially confounding variables such as age, gender, alcohol consumption, and HIV status.OBJETIVO: Revisar evidencia epidemiológica relativa a la asociación entre el tabaquismo y la tuberculosis. MATERIALES Y MÉTODOS: Se identificaron artículos de revisión mediante la búsqueda en Pubmed de los términos "tabaquismo", "tabaco" y "tuberculosis". Se obtuvieron artículos adicionales de las bibliografías de los trabajos identificados. RESULTADOS: Se revisaron 34 estudios: cinco investigan la asociación entre tabaquismo y mortalidad a partir de la tuberculosis; 13, la asociación entre tabaquismo y el desarrollo de tuberculosis; ocho, la asociación entre tabaquismo y la infección con Mycobacterium tuberculosis; y nueve estiman el impacto del tabaquismo en las características de la tuberculosis y las

  12. Variation in radiation doses in paediatric cardiac catheterisation procedures

    International Nuclear Information System (INIS)

    Al-Haj, A. N.; Lobriguito, A. M.; Rafeh, W.

    2008-01-01

    Paediatric cardiac catheterisation involves diagnostic and therapeutic procedures that range from simple to complex and can subject paediatric patients to varying radiation doses. The study aims to determine the variation in entrance doses in patients in terms of dose-area product (DAP) values and to investigate the methods for optimising radiation protection. A total of 190 paediatric patients belonging to age groups 0, 1, 5 and 10 y who underwent diagnostic and six selected therapeutic procedures at King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia) were included in the study. Therapeutic procedures include coarctation (COA), patent ductus arteriosus (PDA), radiofrequency ablation, pulmonary, embolisation and septostomy. Fluoroscopy and cine radiography were used in all procedures. Patient demography (weight, age, gender and height), radiographic technique factors, fluoroscopy and cine time, frame rate, and DAP values were taken from patients records. Effective doses for each procedure were estimated from the DAP values. The mean DAP per procedure were analysed for correlation with patient equivalent cylindrical diameter, weight, fluoroscopy time and number of frames. Factors influencing the variation in doses were investigated. Initial results show that PDA occlusion has the highest mean DAP value of 23.21 Gy-cm 2 , while the diagnostic and septostomy procedures have the lowest value of 7.77 and 6.95 Gy-cm 2 , respectively. (authors)

  13. Calculation method for gamma-dose rates from spherical puffs

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.; Deme, S.; Lang, E.

    1993-05-01

    The Lagrangian puff-models are widely used for calculation of the dispersion of atmospheric releases. Basic output from such models are concentrations of material in the air and on the ground. The most simple method for calculation of the gamma dose from the concentration of airborne activity is based on semi-infinite cloud model. This method is however only applicable for points far away from the release point. The exact calculation of the cloud dose using the volume integral requires significant computer time. The volume integral for the gamma dose could be approximated by using the semi-infinite cloud model combined with correction factors. This type of calculation procedure is very fast, but usually the accuracy is poor due to the fact that the same correction factors are used for all isotopes. The authors describe a more elaborate correction method. This method uses precalculated values of the gamma-dose rate as a function of the puff dispersion parameter (δ p ) and the distance from the puff centre for four energy groups. The release of energy for each radionuclide in each energy group has been calculated and tabulated. Based on these tables and a suitable interpolation procedure the calculation of gamma doses takes very short time and is almost independent of the number of radionuclides. (au) (7 tabs., 7 ills., 12 refs.)

  14. Using body mass index to predict optimal thyroid dosing after thyroidectomy.

    Science.gov (United States)

    Ojomo, Kristin A; Schneider, David F; Reiher, Alexandra E; Lai, Ngan; Schaefer, Sarah; Chen, Herbert; Sippel, Rebecca S

    2013-03-01

    Current postoperative thyroid replacement dosing is weight based, with adjustments made after thyroid-stimulating hormone values. This method can lead to considerable delays in achieving euthyroidism and often fails to accurately dose over- and underweight patients. Our aim was to develop an accurate dosing method that uses patient body mass index (BMI) data. A retrospective review of a prospectively collected thyroid database was performed. We selected adult patients undergoing thyroidectomy, with benign pathology, who achieved euthyroidism on thyroid hormone supplementation. Body mass index and euthyroid dose were plotted and regression was used to fit curves to the data. Statistical analysis was performed using STATA 10.1 software (Stata Corp). One hundred twenty-two patients met inclusion criteria. At initial follow-up, only 39 patients were euthyroid (32%). Fifty-three percent of patients with BMI >30 kg/m(2) were overdosed, and 46% of patients with BMI regression equation was derived for calculating initial levothyroxine dose (μg/kg/d = -0.018 × BMI + 2.13 [F statistic = 52.7, root mean square error of 0.24]). The current standard of weight-based thyroid replacement fails to appropriately dose underweight and overweight patients. Body mass index can be used to more accurately dose thyroid hormone using a simple formula. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Proteinas do liquido cefalorraqueano: I. Estudo comparativo entre metodos de concentração

    Directory of Open Access Journals (Sweden)

    Lucia M. Singer Vermes

    1983-03-01

    Full Text Available No intuito de escolher entre métodos de concentração, aplicáveis ao LCR, aquele que, não provocando desnaturação de proteínas, seja o mais exato, preciso e de fácil aplicação em laboratórios de rotina, foram estudados quatro procedimentos: diálise contra solução de goma-arábica, centrífugo-ultrafiltração, absorção de substâncias de baixo peso molecular por gel seco de poliacrilamida e ultrafiltração sob pressão positiva. Concluiu-se que a diálise contra solução de goma-arábica, por ser preciso, relativamente exato, simples e pouco oneroso, é o mais satisfatório dentre os métodos estudados.

  16. Peripheral dose to the testes: the design and clinical use of a practical and effective gonadal shield

    International Nuclear Information System (INIS)

    Fraass, B.A.; Kinsella, T.J.; Harrington, F.S.; Galtstein, E.

    1985-01-01

    A simple and practical gonadal shield has been developed for use near megavoltage radiation fields. The lead shield encloses only the testes, allowing its use with nearly any radiation field that does not include the testes. The dose to the testes with and without the shield has been measured extensively both in phantoms and on patients. The gonadal shield allows a 3 to 10-fold reduction in dose to the testes depending primarily on the distance from the field edge to the gonads. When the shield is used, the gonadal dose is always less than 1% of the patient's prescription dose. Based on our patient studies of testicular injury following conventionally-fractionated irradiation, a dose of less than 50 cGy should preserve normal testicular function

  17. Calibration and intercomparison methods of dose calibrators used in nuclear medicine facilities

    International Nuclear Information System (INIS)

    Costa, Alessandro Martins da

    1999-01-01

    Dose calibrators are used in most of the nuclear medicine facilities to determine the amount of radioactivity administered to a patient in a particular investigation or therapeutic procedure. It is therefore of vital importance that the equipment used presents good performance and is regular;y calibrated at a authorized laboratory. This occurs of adequate quality assurance procedures are carried out. Such quality control tests should be performed daily, other biannually or yearly, testing, for example, its accuracy and precision, the reproducibility and response linearity. In this work a commercial dose calibrator was calibrated with solution of radionuclides used in nuclear medicine. Simple instrument tests, such as response linearity and the response variation of the source volume increase at a constant source activity concentration, were performed. This instrument can now be used as a working standard for calibration of other dose calibrators/ An intercomparison procedure was proposed as a method of quality control of dose calibrators used in nuclear medicine facilities. (author)

  18. A simple and efficient methodology to improve geometric accuracy in gamma knife radiation surgery: implementation in multiple brain metastases.

    Science.gov (United States)

    Karaiskos, Pantelis; Moutsatsos, Argyris; Pappas, Eleftherios; Georgiou, Evangelos; Roussakis, Arkadios; Torrens, Michael; Seimenis, Ioannis

    2014-12-01

    To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, "average" image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Entre propietarios y migrantes: los encuentros y desencuentros entre Colonos y Aguarunas en el alto mayo”

    Directory of Open Access Journals (Sweden)

    Kenneth E. Garces Montes

    2013-10-01

    Full Text Available La dinámica de conflictos entre colonos y nativos en el Alto Mayo, ha dado como producto continuosenfrentamientos entre caseríos de colonos y comunidades nativas colindantes, así como una seriede procesos judiciales por “usurpación de tierras”, en los cuales no se logra una ejecución efectiva dela sentencia a pesar que esta sea favorable a los nativos, debido a la distancia social que existe entrelos operadores estatales y el conflicto real. Por su parte los mecanismos de convivencia entre colonosy nativos se inician mediante el alquiler de tierras, diseñada como una fórmula temporal para quelos colonos se retiren una vez vencido el plazo del alquiler, sin embargo la ampliación de los plazosprovoca que los mismos adquieran vocación de permanencia.Una serie de actores, de primer, segundo y tercer orden interactúan alrededor de las dos dinámicasde relacionamiento mencionadas; tales como las ONGs, el Estado, organizaciones indígenas, einclusive mafias de traficantes de tierras. Ante esta realidad tan compleja conviene hacer el ejerciciode plantear propuestas de adaptabilidad (o subsistencia de las comunidades nativas, en las quese visualice la supervivencia de lo local frente a lo global en lo que a demarcación de tierras de lascomunidades nativas se refiere.

  20. Uso de álcool e comportamento de saúde entre profissionais da enfermagem

    Directory of Open Access Journals (Sweden)

    Marcelle Aparecida de Barros Junqueira

    2017-11-01

    Full Text Available RESUMO Objetivo: Avaliar o uso problemático de álcool e comportamentos de saúde entre profissionais de enfermagem de um hospital geral. Método: Estudo transversal realizado em um hospital geral. Foi aplicado um questionário com informações sociodemográficas, o teste de triagem do uso álcool e de outras drogas e o questionário de comportamentos de saúde. Resultado: Participaram da pesquisa 416 profissionais. No modelo final da regressão logística, os profissionais do sexo masculino (OR 4,3, solteiros (OR 3,7, que professam outras religiões (OR 3,8, exercem função de técnico de enfermagem (OR 2,3, não consomem baixas doses de bebidas alcoólicas por dia (OR 2,0, fazem uso de tabaco (OR 8,9, evitam o consumo de bebidas com cafeína (OR 1,9 e ambientes barulhentos (OR 2,0 apresentaram chances aumentadas para o consumo de álcool em nível problemático. Conclusão: O uso de álcool e comportamentos de saúde não saudáveis entre profissionais de enfermagem estão fortemente associados. Esses achados têm implicações para a implementação de trabalhos com estratégias de promoção de saúde e prevenção do uso de álcool nas relações de trabalho.

  1. Study on dose-effect relationship of radiation-induced DNA damage using single cell gel electrophoresis

    International Nuclear Information System (INIS)

    Liu Qiang; Jiang Enhai; Li Jin; Tang Weisheng; Wang Zhiquan; Zhao Yongcheng; Fan Feiyue

    2006-01-01

    Objective: To explore a new, simple and quick radiation biodosimeter, which can be applied to estimate biological dose in case of radiation accident. Methods: DNA double-strand break were detected using neutral single cell gel electrophoresis (SCGE), and all the indexes of comet assay including HDNA%, TDNA%, CL, TL, TM, and OTM were analyzed by CASP (Comet Assay Software Project). The curve of dose-effect was fitted using SPSS 12.0 software. Results: Statistically significant dose-effect relationships were observed in all the indexes of comet assay, OTM was superior to other indexes. Conclusions: Application of neutral comet assay combined with CASP analysis could serve as a new radiation biodosimeter. (authors)

  2. SU-F-T-340: Direct Editing of Dose Volume Histograms: Algorithms and a Unified Convex Formulation for Treatment Planning with Dose Constraints

    Energy Technology Data Exchange (ETDEWEB)

    Ungun, B [Stanford University, Stanford, CA (United States); Stanford University School of Medicine, Stanford, CA (United States); Fu, A; Xing, L [Stanford University School of Medicine, Stanford, CA (United States); Boyd, S [Stanford University, Stanford, CA (United States)

    2016-06-15

    Purpose: To develop a procedure for including dose constraints in convex programming-based approaches to treatment planning, and to support dynamic modification of such constraints during planning. Methods: We present a mathematical approach that allows mean dose, maximum dose, minimum dose and dose volume (i.e., percentile) constraints to be appended to any convex formulation of an inverse planning problem. The first three constraint types are convex and readily incorporated. Dose volume constraints are not convex, however, so we introduce a convex restriction that is related to CVaR-based approaches previously proposed in the literature. To compensate for the conservatism of this restriction, we propose a new two-pass algorithm that solves the restricted problem on a first pass and uses this solution to form exact constraints on a second pass. In another variant, we introduce slack variables for each dose constraint to prevent the problem from becoming infeasible when the user specifies an incompatible set of constraints. We implement the proposed methods in Python using the convex programming package cvxpy in conjunction with the open source convex solvers SCS and ECOS. Results: We show, for several cases taken from the clinic, that our proposed method meets specified constraints (often with margin) when they are feasible. Constraints are met exactly when we use the two-pass method, and infeasible constraints are replaced with the nearest feasible constraint when slacks are used. Finally, we introduce ConRad, a Python-embedded free software package for convex radiation therapy planning. ConRad implements the methods described above and offers a simple interface for specifying prescriptions and dose constraints. Conclusion: This work demonstrates the feasibility of using modifiable dose constraints in a convex formulation, making it practical to guide the treatment planning process with interactively specified dose constraints. This work was supported by the

  3. SU-F-T-340: Direct Editing of Dose Volume Histograms: Algorithms and a Unified Convex Formulation for Treatment Planning with Dose Constraints

    International Nuclear Information System (INIS)

    Ungun, B; Fu, A; Xing, L; Boyd, S

    2016-01-01

    Purpose: To develop a procedure for including dose constraints in convex programming-based approaches to treatment planning, and to support dynamic modification of such constraints during planning. Methods: We present a mathematical approach that allows mean dose, maximum dose, minimum dose and dose volume (i.e., percentile) constraints to be appended to any convex formulation of an inverse planning problem. The first three constraint types are convex and readily incorporated. Dose volume constraints are not convex, however, so we introduce a convex restriction that is related to CVaR-based approaches previously proposed in the literature. To compensate for the conservatism of this restriction, we propose a new two-pass algorithm that solves the restricted problem on a first pass and uses this solution to form exact constraints on a second pass. In another variant, we introduce slack variables for each dose constraint to prevent the problem from becoming infeasible when the user specifies an incompatible set of constraints. We implement the proposed methods in Python using the convex programming package cvxpy in conjunction with the open source convex solvers SCS and ECOS. Results: We show, for several cases taken from the clinic, that our proposed method meets specified constraints (often with margin) when they are feasible. Constraints are met exactly when we use the two-pass method, and infeasible constraints are replaced with the nearest feasible constraint when slacks are used. Finally, we introduce ConRad, a Python-embedded free software package for convex radiation therapy planning. ConRad implements the methods described above and offers a simple interface for specifying prescriptions and dose constraints. Conclusion: This work demonstrates the feasibility of using modifiable dose constraints in a convex formulation, making it practical to guide the treatment planning process with interactively specified dose constraints. This work was supported by the

  4. Approaches to reducing photon dose calculation errors near metal implants

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jessie Y.; Followill, David S.; Howell, Rebecca M.; Mirkovic, Dragan; Kry, Stephen F., E-mail: sfkry@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States); Liu, Xinming [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States); Stingo, Francesco C. [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States)

    2016-09-15

    Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well as two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact

  5. Approaches to reducing photon dose calculation errors near metal implants

    International Nuclear Information System (INIS)

    Huang, Jessie Y.; Followill, David S.; Howell, Rebecca M.; Mirkovic, Dragan; Kry, Stephen F.; Liu, Xinming; Stingo, Francesco C.

    2016-01-01

    Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well as two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact

  6. Dose rates of beach sands along the Enshu-nada coast

    International Nuclear Information System (INIS)

    Minato, Susumu; Shimo, Michikuni

    2014-01-01

    In order to understand the mechanism of beach-to-beach variations in dose rates, measurements at 35 sand beaches were carried out along the Enshu-nada coast (a total of 140km). The sand samples were collected at 10 beaches to obtain the concentrations of potassium, uranium and thorium by means of Ge(Li) spectroscopy. Factors affecting the variation in dose rates were discussed, incorporating these data with data of coastal sea-bottom sediments taken by the Geological Survey of Japan. Two-dimensional measurements were performed at 50 locations each in two beaches near the Tenryu river mouth to know within-beach variations in detail. Contour maps of the data revealed a considerable regularity. It was found from simple analyses of the data collected in this work that the dose rate levels at beaches are affected by the distance from the river mouth, erosion or sedimentation of beach, and depth distribution of seawater. (author)

  7. The Sandia total-dose estimator: SANDOSE description and user guide

    International Nuclear Information System (INIS)

    Turner, C.D.

    1995-02-01

    The SANdia total-DOSe Estimator (SANDOSE) is used to estimate total radiation dose to a (BRL-CAT) solid model, SANDOSE uses the mass-sectoring technique to sample the model using ray-tracing techniques. The code is integrated directly into the BRL-CAD solid model editor and is operated using a simple graphical user interface. Several diagnostic tools are available to allow the user to analyze the results. Based on limited validation using several benchmark problems, results can be expected to fall between a 10% underestimate and a factor of 2 overestimate of the actual dose predicted by rigorous radiation transport techniques. However, other situations may be encountered where the results might fall outside of this range. The code is written in C and uses X-windows graphics. It presently runs on SUN SPARCstations, but in theory could be ported to any workstation with a C compiler and X-windows. SANDOSE is available via license by contacting either the Sandia National Laboratories Technology Transfer Center or the author

  8. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  9. Understanding pressurized metered dose inhaler performance.

    Science.gov (United States)

    Ivey, James W; Vehring, Reinhard; Finlay, Warren H

    2015-06-01

    Deepening the current understanding of the factors governing the performance of the pressurized metered dose inhaler (pMDI) has the potential to benefit patients by providing improved drugs for current indications as well as by enabling new areas of therapy. Although a great deal of work has been conducted to this end, our knowledge of the physical mechanisms that drive pMDI performance remains incomplete. This review focuses on research into the influence of device and formulation variables on pMDI performance metrics. Literature in the areas of dose metering, atomization and aerosol evolution and deposition is covered, with an emphasis on studies of a more fundamental nature. Simple models which may be of use to those developing pMDI products are summarized. Although researchers have had good success utilizing an empirically developed knowledge base to predict pMDI performance, such knowledge may not be applicable when pursuing innovations in device or formulation technology. Developing a better understanding of the underlying mechanisms is a worthwhile investment for those working to enable the next generation of pMDI products.

  10. Assessment of dose during an SGTR

    International Nuclear Information System (INIS)

    Adams, J.P.

    1993-01-01

    The Nuclear Regulatory Commission requires utilities to determine the response of a pressurized water reactor to a steam generator tube rupture (SGTR) as part of the safety analysis for the plant. The SGTR analysis includes assumptions regarding the iodine concentration in the reactor coolant system (RCS) due to iodine spikes, primary flashing and bypass fractions, and iodine partitioning in the secondary coolant system (SCS). Experimental and analytical investigations have recently been completed wherein these assumptions were tested to determine whether and to what degree they were conservative (that is, whether they result in a calculated iodine source term/dose that is at least as large or larger than that expected during an actual event). The current study has the objective to assess the overall effects of the results of these investigations on the calculated iodine dose to the environment during an SGTR. To assist in this study, a computer program, DOSE, was written. This program uses a simple, non-mechanistic model to calculate the iodine source term to the environment during an SGTR as a function of water mass inventories and flow rates and iodine concentrations in the RCS and SCS. The principal conclusion of this study is that the iodine concentration in the RCS is the dominant parameter, due to the dominance of primary flashing on the iodine source term

  11. Nexos estratégicos entre la retórica y la publicidad

    Directory of Open Access Journals (Sweden)

    Luis Gallardo Vera

    2011-06-01

    Full Text Available El presente artículo contribuye a establecer nexos estratégicos entre la retórica y la publicidad. La adopción del prisma estratégico en los estudios retóricos de la publicidad no es común, sin embargo, la relación entre retórica y publicidad a un nivel estratégico es evidente, teniendo presente los estudios que han investigado la simbiosis entre las dos actividades.Del universo compuesto por las investigaciones sobre retórica y publicidad se seleccionó una muestra de las obras susceptibles de responder a la pregunta de cuáles son los nexos estratégicos entre la retórica y la publicidad. Con este criterio se conformó una muestra teóricamente conducida del universo. La hipótesis de partida ha sido que, si existen documentos que indaguen en la relación entre la retórica y la publicidad, es posible construir un documento que muestre de un modo amplio cuáles son los nexos estratégicos entre ambas actividades. Finalmente, se contrastó que, efectivamente, este documento es único al mostrar ampliamente cuáles son los nexos estratégicos existentes entre la retórica y la publicidad.

  12. Les Affinités électives de Goethe : entre science et littérature

    Directory of Open Access Journals (Sweden)

    Bernard Joly

    2011-03-01

    Full Text Available Par leur titre même, Les affinités électives de Goethe renvoient à la doctrine chimique des rapports entre différents corps qui, à partir des travaux d’Etienne-François Geoffroy en 1718, s’impose comme théorie dominante dans la chimie du XVIIIe siècle. Goethe ne se contente pas d’une simple analogie entre les attirances amoureuses qui font et défont les couples et les opérations chimiques qui règlent les liaisons et les précipitations des substances chimiques. Son excellente connaissance de la tradition chimique et alchimique le conduit à considérer l’affinité comme une loi de la nature produisant aussi bien ses effets en chimie que chez les êtres vivants et dans le psychisme.The title of Goethe’s novel Elective Affinities refer to the chemical tenet of rapports between different bodies which, from Etienne-François Geoffroy’s works in 1718, emerge as a prevailing theory in the eighteenth-century chemistry. Goethe does not limit his views to the analogy between love attractions which made and break up couples and chimical processes which determine bonds and precipitations of chemical substances. His excellent knowledge of chemical and alchemical tradition leads him to consider affinity as a law of nature having effects in chemistry as well as in living being and into mind.

  13. A method for radiobiological investigations in radiation fields with different LET and high dose rates

    International Nuclear Information System (INIS)

    Grundler, W.

    1976-01-01

    For investigations: 1. Performed in the field of radiobiology with different LET-radiation and a relatively high background dose rate of one component (e.g. investigations with fast and intermediate reactor neutrons) 2. Concerning radiation risk studies within a wide range 3. Of irradiations, covering a long time period (up to 100 days) a test system is necessary which on the one hand makes it possible to analyze the influence of different LET radiation and secondly shows a relative radiation resistant behaviour and allows a simple cell cycle regulation. A survey is given upon the installed device of a simple cell observation method, the biological test system used and the analysis of effects caused by dose, repair and LET. It is possible to analyze the behaviour of the nonsurvival cells and to demonstrate different reactions of the test parameters to the radiation of different LET. (author)

  14. Review of techniques and detectors used in instruments for field measurement of β doses and dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1984-01-01

    Generally, field measurements are required to assess the hazard from β-rays before personnel are allowed to occupy a working space or perform a task. Occasionally, the measurements are required for an assessment after a β-ray exposure is suspected to have occurred. With these uses of field instruments in mind, the following detectors and associated techniques will be discussed in terms of the measurement principles, advantages, and limitations: 1) thin-walled ion chambers (sometimes in combination with thick-walled ones or with covers thick enough to prevent penetration of β-particles); 2) thin scintillators, nearly tissue equivalent, to provide a detector analogous to skin; 3) scintillators, thick enough to absorb all the energy of the β-particles. Circuitry is required to count pulses according to size to permit calculation of dose or dose rate; 4) silicon diodes with thin detection layers operated as photocurrent generators; 5) silicon diodes, reversed biassed, with pulses counted according to size; 6) simple pulse counters (e.g., GM counters or silicon diodes with thin windows)

  15. Development of a Simple Radioactive marker System to Reduce Positioning Errors in Radiation Treatment

    International Nuclear Information System (INIS)

    William H. Miller; Dr. Jatinder Palta

    2007-01-01

    The objective of this research is to implement an inexpensive, quick and simple monitor that provides an accurate indication of proper patient position during the treatment of cancer by external beam X-ray radiation and also checks for any significant changes in patient anatomy. It is believed that this system will significantly reduce the treatment margin, provide an additional, independent quality assurance check of positioning accuracy prior to all treatments and reduce the probability of misadministration of therapeutic dose

  16. Radiation dose distributions close to the shower axis calculated for high energy electron initiated electromagnetic showers in air

    International Nuclear Information System (INIS)

    Geer, S.; Gsponer, A.

    1983-01-01

    Absorbed radiation doses produced by 500, 1,000 and 10,000 MeV electron initiated electromagnetic showers in air have been calculated using a Monte Carlo program. The radial distributions of the absorbed dose near to the shower axis are found to be significantly narrower than predicted by simple analytical shower theory. For a 500 MeV, 10 kA, 100 ns electron beam pulse, the region in which the total dose is in excess of 1 krad and the dose rate in excess of 10 10 rad/s is a cigar-shaped envelope of radius 1 m and length 200 m. (orig.) [de

  17. Análise da dose do laser de baixa potência em equipamentos nacionais Analysis of low-level laser therapy doses in Brazilian equipment

    Directory of Open Access Journals (Sweden)

    TY Fukuda

    2008-02-01

    Full Text Available CONTEXTUALIZAÇÃO: A laserterapia de baixa potência vem sendo cada vez mais utilizada, e o crescente interesse por seus efeitos relaciona-se com a grande quantidade de publicações científicas. Muitos terapeutas e pesquisadores têm-se baseado na definição da dose do laser pela densidade energética (deltaE; porém, a grande variedade de equipamentos de laser pode levar a diferença nos resultados terapêuticos encontrados, por fornecerem parâmetros que variam de acordo com o fabricante. OBJETIVO: Analisar a energia final transmitida ao tecido ao aplicar-se a mesma deltaE em equipamentos de diferentes marcas nacionais. MATERIAIS E MÉTODOS: Foram avaliados sete equipamentos nacionais, com potência média (Pm diferentes, e foram realizadas simulações aplicando deltaE de 1J/cm² em cada aparelho, para avaliar possíveis diferenças na energia final. RESULTADOS: A mesmadeltaE aplicada em diferentes aparelhos nacionais forneceu energia final que variou entre 10 e 90mJ. Esta variação na energia deveu-se principalmente a diferenças na Pm, sendo encontrados valores entre 5,4 e 75mW. CONCLUSÃO: Esta variabilidade na energia final, que é transmitida ao tecido, indica que a deltaE parece não ser o parâmetro que melhor descreve a dose a ser utilizada. É preciso mencionar não só a deltaE, mas também a energia final, para que se possa estabelecer a dose para obtenção do melhor resultado terapêutico.INTRODUCTION: Low-level laser therapy is becoming more popular and there is a growing interest in its effects, as reflected in the increased number of articles published about the subject. Many therapists and researchers have used a laser dose definition based on energy density (deltaE. However, the variety of laser equipments may lead to differences in the therapeutic results found, since the parameters supplied by these equipments vary according to the manufacturer. OBJECTIVE: To analyze the final energy transmitted to the tissue when

  18. Improvement of dose distribution of esophageal irradiation using the field-within-a-field technique

    International Nuclear Information System (INIS)

    Iwai, Tsugunori; Okabe, Keigo; Yamato, Hidetada; Murakami, Jyunji; Nakazawa, Yasuo; Kato, Mitsuyoshi

    2002-01-01

    The wide radiation field for mediastinal dose distribution should be inhomogeneous with the usual simple opposed beam irradiation. The purpose of this study was to improve the dose distribution of the mediastinum using a conventional planning system with a dose-volume histogram (DVH) and the field-in-field technique. Three-dimensional (3D) dose distribution is obtained in bilateral opposed-field irradiation. An overdose area obtained from the 3D dose distribution is defined and reprojected into the irradiation field. A new reduced field is created by removing the reprojected overdose area. A 3D dose distribution is again obtained and compared with the results from first one. Procedures were repeated until each of the target volumes was within ±5% of the prescribed dose and the irradiation volume within 107% or less of the prescribed dose. From the DVH analysis, our field-within-a-field technique resulted in a more uniform dose distribution within the conventional planning. The field-within-a-field technique involves many parameters, and an inverse planning algorithm is suitable for computation. However, with our method, the forward planning system is adequate for planning, at least in a relatively straightforward planning system such as bilateral opposed fields therapy. (author)

  19. Civilidad y barbarie. Acerca de las relaciones entre sociedad civil y política

    Directory of Open Access Journals (Sweden)

    Fernando Mires

    2001-01-01

    Full Text Available En este artículo se intentará establecer las relaciones y diferencias que se dan entre un orden pre-político y uno político ropiamente tal. Lo pre-político, así como lo no-político serán entendidos, de acuerdo con la dicotomía ateniense, como situaciones en las cuales impera el reino de la barbarie, que no significa, en ese contexto, ausencia de cultura, sino ausencia de lo político, que a su vez, aparece principalmente como un espacio de regulación de antagonismos en los cuales se recurre, en primera instancia, a la palabra oral o escrita como medio de resolución conflictual. No obstante, entre barbarie y política no sólo hay contradicción, sino que, además, cada una de estas dimensiones se contiene germinalmente en la otra. Ni los procesos de modernización económica, ni los de racionalización burocrática limitan de por sí, automáticamente, el avance de la barbarie. Ello sólo será posible mediante el desarrollo de una cultura política que sólo puede formarse en oposición y antagonismo a todo lo que la niega, sea la dominación totalitaria que aún permanece en algunas zonas del planeta, sea la simple dominación dictatorial, cuyos peligros todavía se esconden al interior de algunos cuarteles latinoamericanos.

  20. CARACTERÍSTICAS AGRONÔMICAS DE CULTIVARES DE SORGO (Sorghum bicolor (L. Moench SOB TRÊS DOSES DE NITROGÊNIO AGRONOMIC TRAITS OF SORGHUM CULTIVARS AT THREE LEVELS OF NITROGEN FERTILIZER

    Directory of Open Access Journals (Sweden)

    Susana Queiroz Santos Mello

    2007-09-01

    Full Text Available

    O objetivo do trabalho foi avaliar as características agronômicas de quatro cultivares de sorgo forrageiros, submetidas a três doses de nitrogênio, em solo classificado como Latossolo vermelho distrófico argiloso. Utilizou-se o delineamento blocos casualizados, em esquema fatorial 4x3. As cultivares foram os híbridos CMSXS 762, BRS 610, BR 700 e a variedade BR 506, com três doses de nitrogênio: 50 kg.ha-1, 75 kg.ha-1 e 100 kg.ha-1. A produção de matéria natural, com média geral de 59,31 t.ha-1, diferiu entre as cultivares (teste Tukey a 5% de probabilidade, porém, não diferiu em função das doses de nitrogênio. A produção de massa seca, com média de 15,17 t.ha-1, não diferiu entre as cultivares, nem entre as doses de N. Já os teores de matéria seca e as porcentagens de panícula e de colmo na matéria natural diferiram tanto entre as cultivares como em função das doses. A altura das plantas, com média geral de 2,39 m, e o teor de matéria seca do colmo diferiram somente entre as cultivares. As cultivares BR 700 e CMSXS 762 apresentaram uma melhor relação entre panícula/colmo/folha e uma maior porcentagem de panícula. E, à medida que se aumentou a dose de nitrogênio, verificou-se maior participação de panícula, com redução na percentagem de colmo.

    PALAVRAS-CHAVE: Sorgo; adubação nitrogenada; avaliação agronômica.

    The objective of this study was to evaluate characteristics of four forage sorghum cultivars at three levels of nitrogen fertilizer in an Oxisoil. A randomized complete block design in a 4x3 factorial scheme (CMSXS 762, BRS 610, BR 700 and BR 506 hybrid cultivars combined with 50 kg.ha-1, 75 kg.ha-1 and 100 kg.ha-1 nitrogen levels. A Tukey

  1. Biology of dose rate in brachytherapy

    International Nuclear Information System (INIS)

    Brenner, David J.

    1995-01-01

    rate decreases over the practical lifetime of a given source? If so, how should the corrections be made? Pulsed dose rate (PDR): Here, a continuous low dose rate treatment is replaced with a system in which a single radioactive source shuttles, under computer control, through catheters implanted in the tumor, typically for 10 minutes in the hour. Advantages include the use of only one radioactive source, replacing the large inventory usually needed, patient mobility during treatment, and the potential for dose optimization as the source shuttles through the tumor. Does PDR work? Is it equivalent to conventional LDR? Is it practical? Optimized time schedules in brachytherapy: Does conventional LDR really give the very best therapeutic advantage between tumor control and late effects? It probably does not, and simple alternative schemes that should do better will be discussed

  2. Patient dose reference values for explorations of radiodiagnostic

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Moran, P.; Calzado, A.; Delgado, V.; Ruiz, M.J.

    1992-01-01

    Among the results of the research programs developed in the European Community dealing with radiological protection, dose estimation and quality control in radiodiagnostics, the preparation of a document on Quality criteria for radiodiagnostic images is worthy of note. This document proposes criteria for image quality and patient dose reference values for explorations of thorax, cranium, lumbar region, pelvis, urinary tract and breast. Said reference values, while indicative, are merely an average approximation, from which the radiodiagnostic services of each area may differ significantly, as can be deduced from a EC-coordinated project. With this in mind, and following a strategy applied in the EC to establish said reference values, in this report, provisional reference values, specific for Spain, are proposed for simple examinations (those analyzed by the group of EC experts, among others) and complex probes (intravenous urography, opaque enema and esophagogastroduodenal enema). (author)

  3. Calculation method for gamma dose rates from Gaussian puffs

    Energy Technology Data Exchange (ETDEWEB)

    Thykier-Nielsen, S; Deme, S; Lang, E

    1995-06-01

    The Lagrangian puff models are widely used for calculation of the dispersion of releases to the atmosphere. Basic output from such models is concentration of material in the air and on the ground. The most simple method for calculation of the gamma dose from the concentration of airborne activity is based on the semi-infinite cloud model. This method is however only applicable for puffs with large dispersion parameters, i.e. for receptors far away from the release point. The exact calculation of the cloud dose using volume integral requires large computer time usually exceeding what is available for real time calculations. The volume integral for gamma doses could be approximated by using the semi-infinite cloud model combined with correction factors. This type of calculation procedure is very fast, but usually the accuracy is poor because only a few of the relevant parameters are considered. A multi-parameter method for calculation of gamma doses is described here. This method uses precalculated values of the gamma dose rates as a function of E{sub {gamma}}, {sigma}{sub y}, the asymmetry factor - {sigma}{sub y}/{sigma}{sub z}, the height of puff center - H and the distance from puff center R{sub xy}. To accelerate the calculations the release energy, for each significant radionuclide in each energy group, has been calculated and tabulated. Based on the precalculated values and suitable interpolation procedure the calculation of gamma doses needs only short computing time and it is almost independent of the number of radionuclides considered. (au) 2 tabs., 15 ills., 12 refs.

  4. Calculation method for gamma dose rates from Gaussian puffs

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.; Deme, S.; Lang, E.

    1995-06-01

    The Lagrangian puff models are widely used for calculation of the dispersion of releases to the atmosphere. Basic output from such models is concentration of material in the air and on the ground. The most simple method for calculation of the gamma dose from the concentration of airborne activity is based on the semi-infinite cloud model. This method is however only applicable for puffs with large dispersion parameters, i.e. for receptors far away from the release point. The exact calculation of the cloud dose using volume integral requires large computer time usually exceeding what is available for real time calculations. The volume integral for gamma doses could be approximated by using the semi-infinite cloud model combined with correction factors. This type of calculation procedure is very fast, but usually the accuracy is poor because only a few of the relevant parameters are considered. A multi-parameter method for calculation of gamma doses is described here. This method uses precalculated values of the gamma dose rates as a function of E γ , σ y , the asymmetry factor - σ y /σ z , the height of puff center - H and the distance from puff center R xy . To accelerate the calculations the release energy, for each significant radionuclide in each energy group, has been calculated and tabulated. Based on the precalculated values and suitable interpolation procedure the calculation of gamma doses needs only short computing time and it is almost independent of the number of radionuclides considered. (au) 2 tabs., 15 ills., 12 refs

  5. Violencia sexual entre compañeros y violencia en parejas adolescentes

    OpenAIRE

    Ortega Ruiz, Rosario; Ortega Rivera, Francisco Javier; Sánchez Jiménez, Virginia

    2008-01-01

    El presente estudio ha analizado la presencia de violencia sexual entre compañeros y en las parejas adolescentes y jóvenes. Específicamente se han estudiado las diferencias por sexo, edad y estadio de la relación sentimental tanto en violencia sexual entre iguales como en las parejas, en una muestra de 490 adolescentes (55,7% chicos, 44,3% chicas, edad media 16.08 años). Los resultados descriptivos mostraron la misma incidencia de violencia sexual entre iguales y en las pa...

  6. Arquitectura de comunicación entre frameworks jadesymfony

    OpenAIRE

    RODRÍGUEZ C., PAOLA J.; GÓMEZ R., SANTIAGO

    2009-01-01

    La inclusión del uso de Agentes dentro del campo del desarrollo de software es una de las principales áreas de estudio en la actualidad. Específicamente, el desarrollo de aplicaciones Web que aprovechen las ventajas que ofrece la tecnología de agentes y en especial las distintas propuestas de comunicación entre frameworks son esfuerzos importantes dentro de este campo. En este sentido, este artículo describe una arquitectura de comunicación entre dos de los principales frameworks de desarroll...

  7. The applicability of the PTTL dose re-analysis method to the Harshaw LiF:Mg,Cu,P material

    International Nuclear Information System (INIS)

    Moscovitch, M.; Benevides, L.; Romanyukha, A.; Hull, F.; Duffy, M.; Voss, S.; Velbeck, K. J.; Nita, I.; Rotunda, J. E.

    2011-01-01

    The photo-transferred thermoluminescence (PTTL) technique is applied to the Harshaw LiF:Mg,Cu,P material. It is demonstrated that using 254-nm UV light, dose levels as low as 0.2 mGy can be re-estimated. The PTTL efficiency was found to be ∼6 % in the dose range of 0.2 mGy -1 Gy, and it appears to be dose-independent. This implies that a simple calibration factor could be applied to the PTTL data for the re-estimation of dose levels. It was demonstrated that with a proper choice of the TL readout parameters, and the UV-light irradiation conditions, dose levels that are relevant to personal or environmental dosimetry can be re-estimated. (authors)

  8. Peripheral dose to the testes: the design and clinical use of a practical and effective gonadal shield.

    Science.gov (United States)

    Fraass, B A; Kinsella, T J; Harrington, F S; Glatstein, E

    1985-03-01

    A simple and practical gonadal shield has been developed for use near megavoltage radiation fields. The lead shield encloses only the testes, allowing its use with nearly any radiation field that does not include the testes. The dose to the testes with and without the shield has been measured extensively both in phantoms and on patients. The gonadal shield allows a 3 to 10-fold reduction in dose to the testes depending primarily on the distance from the field edge to the gonads. When the shield is used, the gonadal dose is always less than 1% of the patient's prescription dose. Based on our patient studies of testicular injury following conventionally-fractionated irradiation, a dose of less than 50 cGy (1% of a typical 5000 cGy treatment regimen) should preserve normal testicular function.

  9. Estimation of the absorbed dose in gamma irradiated food containing bone by electron spin resonance spectroscopy

    International Nuclear Information System (INIS)

    Basfar, A.A.; Abdel Rehim, F.

    1997-01-01

    The use of electron spin resonance (ESR) spectroscopy to accurately evaluate the absorbed dose to radiationprocessed bones (and thus meats) is examined. The exposure of foodstuffs containing bone to a dose of ionizing radiation results in the formation of long lived free radicals which give rise to characteristics ESR signals. The yield of radicals was found to be proportional to absorbed dose. Additive re-irradiation of previously irradiated bone was used to estimate the absorbed dose in the irradiated chicken bone. Simple non-linear rational equation was found to fit to the data and yields good dose estimates for irradiated bone in the range of doses (1.0 - 5.0 kGy). Decay of the ESR signal intensity was monitored at different dose levels (2.0 and 7.0 kGy) up to 22 days. The absorbed dose in irradiated chicken (2.Om 3.0 and 6.0 kGy) was assessed at 2, 6 and 12 days after irradiation. Relatively good results were obtained when measurements were made within the following days (up to 12 days) after irradiation. The ability of the dose additive method to provide accurate dose assessments is tested here

  10. A survey of chest medical X-ray doses

    International Nuclear Information System (INIS)

    Lomba, M.; Conha, P.G. da; Almeida, C.E. de

    1996-01-01

    The medical X-ray exposures due to radiological examinations are responsible for the largest contribution to the population collective dose as result of the normal use of artificial sources of radiation. The relative impact of the medical exposures to the total dose received by the population from all kinds of radiation sources varies from country to country and in some cases within the same country. The dose variations observed for a specific type of examination are in general associated to several factors i.e. the type of film-ecran combination, the choice of the appropriate physical parameters of the X-ray generator (Kvp, filament current, exposure time) and finally to the film processing conditions. At the present moment the data available in Brazil are scarce and scanty to allow a complete analyzis of this question so needed by the health authorities to justify the implementation of a quality assurance and dose reduction programs. In addition, it is desirable to establish a cost effective operation based on simple administrative concepts in order to reduce the number of films retake, then increasing the life expectancy of the equipment and the number of radiological procedures. The aim of this work was to assess the typical doses of an PA and LAT chest wall X-ray examinations in five different public hospitals (a University Hospital, a Cancer Hospital, a Navy Hospital, an Emergency Hospital and a State General Hospital), as representative of the city of Rio de Janeiro, and compare the results with the international data and recommendations available. (author)

  11. A randomized controlled trial of vitamin D dosing strategies after acute hip fracture: No advantage of loading doses over daily supplementation

    Directory of Open Access Journals (Sweden)

    Farrauto Leonardo

    2011-06-01

    Full Text Available Abstract Background There remains uncertainty regarding the appropriate therapeutic management of hip fracture patients. The primary aim of our study was to examine whether large loading doses in addition to daily vitamin D offered any advantage over a simple daily low-dose vitamin D regimen for increasing vitamin D levels. Methods In this randomized controlled study, patients over age 50 with an acute fragility hip fracture were enrolled from two hospital sites in Ontario, Canada. Participants were randomized to one of three loading dose groups: placebo; 50,000 IU vitamin D2; or 100,000 IU D2. Following a placebo/loading dose, all patients received a daily tablet of 1,000 IU vitamin D3 for 90 days. Serum 25-hydroxy vitamin D (25-OHD was measured at baseline, discharge from acute care (approximately 4-weeks, and 3-months. Results Sixty-five patients were enrolled in the study (44% male. An immediate rise in 25-OHD occurred in the 100,000 group, however there were no significant differences in 25-OHD between the placebo, 50,000 and 100,000 loading dose groups after 4-weeks (69.3, 84.5, 75.6 nmol/L, p = 0.15 and 3-months (86.7, 84.2, 73.3 nmol/L, p = 0.09, respectively. At the end of the study, approximately 75% of the placebo and 50,000 groups had reached the target therapeutic range (75 nmol/L, and 44% of the 100,000 group. Conclusions In correcting vitamin D insufficiency/deficiency in elderly patients with hip fracture, our findings suggest that starting with a lower daily dose of Vitamin D3 achieved similar results as providing an additional large loading dose of Vitamin D2. At the end of the study, all three groups were equally effective in attaining improvement in 25-OHD levels. Given that a daily dose of 1,000 IU vitamin D3 (with or without a loading dose resulted in at least 25% of patients having suboptimal vitamin D status, patients with acute hip fracture may benefit from a higher daily dose of vitamin D. Trial registration Clinical

  12. RELACIÓN ENTRE DIFERENTES PRUEBAS DE CAMPO: FUERZA, POTENCIA Y VELOCIDAD

    Directory of Open Access Journals (Sweden)

    Jessenia Hernández Elizondo

    2003-12-01

    Full Text Available Esta investigación tuvo como propósito principal el encontrar por medio de pruebas en las variables de fuerza, potencia y velocidad, la relación matemática existente entre estos tres constructos. Participaron 56 sujetos varones con edades entre 18 y 25 años. Con el fin de responder al objetivo del estudio, se les aplicaron pruebas de campo de fuerza (1RM de sentadilla completa y repeticiones máximas al 80% 60% 40% y 20%, de velocidad (30 metros lanzados y 30 metros sin impulso, y de potencia (salto vertical con contra-movimiento SVCM, salto vertical sin impulso SVSI y salto vertical con caída SVCC, para correlacionar las diferentes pruebas entre sí. Los datos fueron analizados por medio de la correlación de Pearson (r, para correlacionar parejas de pruebas y correlación canónica (Rc para correlacionar grupos de variables. A partir de cada correlación se obtuvo la varianza explicada (r2 la cual indica el porcentaje de relación compartida en escala de 0-100 que existe entre las pruebas. Según los datos obtenidos, no existe relación significativa (2.1% entre las pruebas de salto-sentadilla, ni relación significativa (5.1% entre las pruebas de velocidad- sentadilla, mientras que la relación salto- velocidad (62%, fue estadísticamente significativa (p < 0.05. La implicación de estos resultados podrían respaldar la idea de que la relación teórica que existe entre estos constructos, no es completamente cierta cuando éstos son medidos por medio de pruebas de campo.

  13. Dosimetry investigation of MOSFET for clinical IMRT dose verification.

    Science.gov (United States)

    Deshpande, Sudesh; Kumar, Rajesh; Ghadi, Yogesh; Neharu, R M; Kannan, V

    2013-06-01

    In IMRT, patient-specific dose verification is followed regularly at each centre. Simple and efficient dosimetry techniques play a very important role in routine clinical dosimetry QA. The MOSFET dosimeter offers several advantages over the conventional dosimeters such as its small detector size, immediate readout, immediate reuse, multiple point dose measurements. To use the MOSFET as routine clinical dosimetry system for pre-treatment dose verification in IMRT, a comprehensive set of experiments has been conducted, to investigate its linearity, reproducibility, dose rate effect and angular dependence for 6 MV x-ray beam. The MOSFETs shows a linear response with linearity coefficient of 0.992 for a dose range of 35 cGy to 427 cGy. The reproducibility of the MOSFET was measured by irradiating the MOSFET for ten consecutive irradiations in the dose range of 35 cGy to 427 cGy. The measured reproducibility of MOSFET was found to be within 4% up to 70 cGy and within 1.4% above 70 cGy. The dose rate effect on the MOSFET was investigated in the dose rate range 100 MU/min to 600 MU/min. The response of the MOSFET varies from -1.7% to 2.1%. The angular responses of the MOSFETs were measured at 10 degrees intervals from 90 to 270 degrees in an anticlockwise direction and normalized at gantry angle zero and it was found to be in the range of 0.98 ± 0.014 to 1.01 ± 0.014. The MOSFETs were calibrated in a phantom which was later used for IMRT verification. The measured calibration coefficients were found to be 1 mV/cGy and 2.995 mV/cGy in standard and high sensitivity mode respectively. The MOSFETs were used for pre-treatment dose verification in IMRT. Nine dosimeters were used for each patient to measure the dose in different plane. The average variation between calculated and measured dose at any location was within 3%. Dose verification using MOSFET and IMRT phantom was found to quick and efficient and well suited for a busy radiotherapy

  14. An independent dose calculation algorithm for MLC-based stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Lorenz, Friedlieb; Killoran, Joseph H.; Wenz, Frederik; Zygmanski, Piotr

    2007-01-01

    We have developed an algorithm to calculate dose in a homogeneous phantom for radiotherapy fields defined by multi-leaf collimator (MLC) for both static and dynamic MLC delivery. The algorithm was developed to supplement the dose algorithms of the commercial treatment planning systems (TPS). The motivation for this work is to provide an independent dose calculation primarily for quality assurance (QA) and secondarily for the development of static MLC field based inverse planning. The dose calculation utilizes a pencil-beam kernel. However, an explicit analytical integration results in a closed form for rectangular-shaped beamlets, defined by single leaf pairs. This approach reduces spatial integration to summation, and leads to a simple method of determination of model parameters. The total dose for any static or dynamic MLC field is obtained by summing over all individual rectangles from each segment which offers faster speed to calculate two-dimensional dose distributions at any depth in the phantom. Standard beam data used in the commissioning of the TPS was used as input data for the algorithm. The calculated results were compared with the TPS and measurements for static and dynamic MLC. The agreement was very good (<2.5%) for all tested cases except for very small static MLC sizes of 0.6 cmx0.6 cm (<6%) and some ion chamber measurements in a high gradient region (<4.4%). This finding enables us to use the algorithm for routine QA as well as for research developments

  15. A desnecessidade do trabalho entre pescadores artesanais

    Directory of Open Access Journals (Sweden)

    Cristiano Wellington Norberto Ramalho

    2015-04-01

    Full Text Available As relações socioculturais e econômicas, entre alguns grupos de pescadores artesanais, não colocam como entes antagônicos trabalho e tempo livre. Do contrário, tais relações celebram aproximações entre saber-fazer pesqueiro, lazer e vida, formando e conformando um todo societário. Inseridos nesse quadro, estão os pescadores artesanais do mar-de-fora da praia de Suape, no município do Cabo de Santo Agostinho, litoral sul de Pernambuco, distante 50 km de Recife. Este artigo busca desvelar a mencionada moral do trabalho e do tempo livre no fazer cotidiano de pescadores dessa Praia, com base na pesquisa etnográfica e na história de vida de 13 pescadores. No geral, identificou-se que há uma moral do trabalho que se confunde à moral do tempo livre, pois o cerceamento de uma delas representa limites à outra. Assim, para esses homens, definir o que é um ser liberto ou cativo liga-se ao encontro indissociável, em termos práticos e simbólicos, entre as referidas morais, o que é essencial para classificar o fazer-se pescador artesanal em seu sentido pleno fundamentado na desnecessidade do trabalho.

  16. El (los Sur buscando al Sur. Una construcción entre estereotipos y realidad.

    Directory of Open Access Journals (Sweden)

    Mabel Franzone

    2010-11-01

    Full Text Available Todas las lecturas que podamos hacer del Sur, de sus propias representaciones, de aquellas vehiculizadas por el Norte, de sus creaciones, de sus reacciones, de su búsqueda constante de identidad, son lecturas de múltiples situaciones, que llaman a cruces insoslayables entre pueblos, entre distintas etnias, entre disciplinas, entre sentimientos que van desde el rechazo hasta la atracción casi magnética entre los dos hemisferios. Nuestra intención primera era la de reunir de manera aproximativa las problemáticas actuales de los Sur, ligadas a lo imaginario.

  17. The comparative study of Yaz and Ovocept-ld on patients with simple ovarian cysts referring to Iran-Isfahan Shariati Hospital

    Directory of Open Access Journals (Sweden)

    Soheyla Riahinejad

    2014-01-01

    Full Text Available Background: Functional ovarian cysts include follicular, corpus luteum, and theca lutein cysts are the most common adnexal masses (about 50% in women of reproductive age. Treatment with the combined monophasic oral contraceptives reduces functional ovarian cysts. Yaz (drospirenone/ethinyl estradiol is a low-dose combined oral contraceptive pill containing 20 μg ethinyl estradiol and 3 mg drospirenone. In addition to contraceptive effects, Yaz has anti-mineralocorticoid and anti-adrenergic effects. Ovocept- low-dose LD is also a low-dose combined oral contraceptive drug containing 30 μg ethinyl estradiol and 3 mg norgestrol. Ovocept-LD has some side-effects such as weight gain, spotting, breast tenderness, nausea, and headache. Materials and Methods: Being a clinical study, the present research was carried out on 42 patients with the simple ovarian cysts from 2010 to 2012. 84 Patients were assigned to A and B groups. Group A received Yaz once a day for a period of 28 days and group B received Ovocept-LD once a day for a period of 21 days. After treating by Yaz and Ovocept-LD, Cysts were evaluated by ultrasound. Results were analyzed by the SPSS software. A P < 0.05 was considered the significance threshold. Results : Obtained results indicated that both Yaz and Ovocept-LD had an effect on the simple ovarian cysts. Statistical tests, however, has shown that the effect of Yaz has been significantly more than that of Ovocept-LD. Conclusion: Given the faster and better recovery effect, and the lesser side effects of Yaz as compared to Ovocept-LD, it is recommended to use Yaz for the simple ovarian cysts.

  18. Entre ritmo e poesia: rap e literatura oral urbana

    Directory of Open Access Journals (Sweden)

    Marcus Rogerio Salgado

    2015-11-01

    Full Text Available O objetivo do presente artigo é um estudo do rap enquanto manifestação de literatura oral urbana e forma de oralidade tecnológica. Para tanto, o artigo passará em revista as relações entre literatura e palavra falada/cantada, assim como as possibilidades de interface estética entre a literatura e a música que estão em questão quando tratamos do rap.

  19. A FOTOGRAFIA ENTRE A ARTE POPULAR E A ARTE ERUDITA

    Directory of Open Access Journals (Sweden)

    Marcos Fabris

    2013-09-01

    Full Text Available Este artigo pretende discutir alguns dos aspectos que marcam o estabelecimento e a dissolução das fronteiras entre dois pólos convencionalmente descritos como arte culta e arte popular, tecendo paralelos entre o teatro de variedades, forma de expressão popular por excelência, e a fotografia, expressão artística que desde seus primórdios circula entre os dois extremos deste contínuo. Nestes termos, ambiciona-se verificar como determinadas condições sócio-históricas favorecem a criação de recursos formais que minimizam, ou suprimem, tais distinções consagradas pela crítica de arte.

  20. Proyectos educativos: estudio comparativo entre Venezuela y Colombia

    Directory of Open Access Journals (Sweden)

    Mineira Finol

    2005-09-01

    Full Text Available El Proyecto Educativo Integral Comunitario (PEIC y el Proyecto Educativo Institucional constituyen la categoría de comparación entre Venezuela y Colombia; a tal fin, este estudio de tipo comparativo-documental se centró en determinar congruencias y discrepancias entre PEIC y PEI, utilizando el método comparativo estructurado en cuatro fases: descripción, interpretación, yuxtaposición y comparación, propuesto por Hilker y Bereday (1972 Entre los resultados se tienen: congruencias en cuanto surgen sobre las bases de diagnóstico externos efectuados por organismos internacionales UNESCO, CEPAL ante la inefectividad y baja productividad de ambos países; a nivel interno responden a políticas educativas reformadoras de currículum y leyes,. Discrepancias referidas al tiempo de implementación; en Venezuela a partir de 1996; Colombia en 1992; este último, consolidó las bases para la participación a través del gobierno escolar y de un sistema de evaluación institucional, muy incipiente en Venezuela.

  1. Radiation dose response of strand breaks in SINPV-DNA

    International Nuclear Information System (INIS)

    Zhang Chunxiang; Luo Daling; Li Mianfeng; Liu Xiaowei; Zeng Rong; Wang Xunzhang

    1995-01-01

    The Spodoplera litura Nuclear Polyhedrosis Viruses (SINPV) is a kind of insectile virus with a simple structure, in which a double helix DNA is encapsulated in a protein coat and there is no function of enzymatic repair. The SINPV samples in dry powdered form held in sealed plastic tube were irradiated by 1-100 kGy gamma rays. The single strand breaks (SSB) and double strand breaks (DSB) induced in SINPV after irradiation were measured by neutral and alkaline agarose gel electrophoresis. A dose-response function combining the responses of one-hit and two-hit events was used to describe the SSB and DSB dose-response curves. It is shown that the SSB are one-hit events and the DSB are the combination of both one-hit, and two-hit events, and two-hit events are predominant in the DSB process

  2. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  3. Eco-friendly and simple radiation-based preparation of graphene and its application to organic solar cells

    International Nuclear Information System (INIS)

    Jung, Chan-Hee; Park, Yong-Woon; Hwang, In-Tae; Choi, Jae-Hak; Go, Yeong-Jin; Na, Seok-In; Shin, Kwanwoo; Lee, Jae-Suk

    2014-01-01

    We report the reduction of graphene oxide (GO) through an eco-friendly and simple radiation-based method and the practical application of the resulting radiation-reduced GO (RRGO) as a solution-processable hole-transporting layer (HTL) for organic solar cells. GO dispersed in N, N′-dimethylformamide (DMF) was irradiated by γ-rays at various absorbed doses. The analytical results revealed that GO in DMF was effectively reduced to RRGO by γ-ray irradiation-induced deoxygenation, and that the reduction degree was dependent on the absorbed dose. The electrical conductivity of RRGO increased up to 12.7 S cm −1 with an increase in the absorbed dose, whereas the work function decreased to 4.34 eV. An organic solar cell device with RRGO prepared at 50 kGy as an HTL exhibited the best performance, with a power conversion efficiency of 2.72%, which is a better cell efficiency than is possible in devices with conventional GO and solvothermally-reduced GO. (paper)

  4. A simple method to retrospectively estimate patient dose-area product for chest tomosynthesis examinations performed using VolumeRAD.

    Science.gov (United States)

    Båth, Magnus; Söderman, Christina; Svalkvist, Angelica

    2014-10-01

    The purpose of the present work was to develop and validate a method of retrospectively estimating the dose-area product (DAP) of a chest tomosynthesis examination performed using the VolumeRAD system (GE Healthcare, Chalfont St. Giles, UK) from digital imaging and communications in medicine (DICOM) data available in the scout image. DICOM data were retrieved for 20 patients undergoing chest tomosynthesis using VolumeRAD. Using information about how the exposure parameters for the tomosynthesis examination are determined by the scout image, a correction factor for the adjustment in field size with projection angle was determined. The correction factor was used to estimate the DAP for 20 additional chest tomosynthesis examinations from DICOM data available in the scout images, which was compared with the actual DAP registered for the projection radiographs acquired during the tomosynthesis examination. A field size correction factor of 0.935 was determined. Applying the developed method using this factor, the average difference between the estimated DAP and the actual DAP was 0.2%, with a standard deviation of 0.8%. However, the difference was not normally distributed and the maximum error was only 1.0%. The validity and reliability of the presented method were thus very high. A method to estimate the DAP of a chest tomosynthesis examination performed using the VolumeRAD system from DICOM data in the scout image was developed and validated. As the scout image normally is the only image connected to the tomosynthesis examination stored in the picture archiving and communication system (PACS) containing dose data, the method may be of value for retrospectively estimating patient dose in clinical use of chest tomosynthesis.

  5. A simple method to retrospectively estimate patient dose-area product for chest tomosynthesis examinations performed using VolumeRAD

    Energy Technology Data Exchange (ETDEWEB)

    Båth, Magnus, E-mail: magnus.bath@vgregion.se; Svalkvist, Angelica [Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, Gothenburg SE-413 45, Sweden and Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg SE-413 45 (Sweden); Söderman, Christina [Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, Gothenburg SE-413 45 (Sweden)

    2014-10-15

    Purpose: The purpose of the present work was to develop and validate a method of retrospectively estimating the dose-area product (DAP) of a chest tomosynthesis examination performed using the VolumeRAD system (GE Healthcare, Chalfont St. Giles, UK) from digital imaging and communications in medicine (DICOM) data available in the scout image. Methods: DICOM data were retrieved for 20 patients undergoing chest tomosynthesis using VolumeRAD. Using information about how the exposure parameters for the tomosynthesis examination are determined by the scout image, a correction factor for the adjustment in field size with projection angle was determined. The correction factor was used to estimate the DAP for 20 additional chest tomosynthesis examinations from DICOM data available in the scout images, which was compared with the actual DAP registered for the projection radiographs acquired during the tomosynthesis examination. Results: A field size correction factor of 0.935 was determined. Applying the developed method using this factor, the average difference between the estimated DAP and the actual DAP was 0.2%, with a standard deviation of 0.8%. However, the difference was not normally distributed and the maximum error was only 1.0%. The validity and reliability of the presented method were thus very high. Conclusions: A method to estimate the DAP of a chest tomosynthesis examination performed using the VolumeRAD system from DICOM data in the scout image was developed and validated. As the scout image normally is the only image connected to the tomosynthesis examination stored in the picture archiving and communication system (PACS) containing dose data, the method may be of value for retrospectively estimating patient dose in clinical use of chest tomosynthesis.

  6. A simple method to retrospectively estimate patient dose-area product for chest tomosynthesis examinations performed using VolumeRAD

    International Nuclear Information System (INIS)

    Båth, Magnus; Svalkvist, Angelica; Söderman, Christina

    2014-01-01

    Purpose: The purpose of the present work was to develop and validate a method of retrospectively estimating the dose-area product (DAP) of a chest tomosynthesis examination performed using the VolumeRAD system (GE Healthcare, Chalfont St. Giles, UK) from digital imaging and communications in medicine (DICOM) data available in the scout image. Methods: DICOM data were retrieved for 20 patients undergoing chest tomosynthesis using VolumeRAD. Using information about how the exposure parameters for the tomosynthesis examination are determined by the scout image, a correction factor for the adjustment in field size with projection angle was determined. The correction factor was used to estimate the DAP for 20 additional chest tomosynthesis examinations from DICOM data available in the scout images, which was compared with the actual DAP registered for the projection radiographs acquired during the tomosynthesis examination. Results: A field size correction factor of 0.935 was determined. Applying the developed method using this factor, the average difference between the estimated DAP and the actual DAP was 0.2%, with a standard deviation of 0.8%. However, the difference was not normally distributed and the maximum error was only 1.0%. The validity and reliability of the presented method were thus very high. Conclusions: A method to estimate the DAP of a chest tomosynthesis examination performed using the VolumeRAD system from DICOM data in the scout image was developed and validated. As the scout image normally is the only image connected to the tomosynthesis examination stored in the picture archiving and communication system (PACS) containing dose data, the method may be of value for retrospectively estimating patient dose in clinical use of chest tomosynthesis

  7. Quantitative Evaluation of Dose-Response Relationships in Human Beings with Skeletal Burdens of Radium-226 and Radium-228; Evaluation Quantitative de la Relation entre Dose et Reponse chez des Sujets Ayant une Charge Squelettique de Radium 226 et Radium 228; 041a 041e 041b 0414 ; Evaluacion Cuantitativa de las Relaciones Dosis-Respuesta en Seres Humanos con Cargas de Radio-226 y Radio-228 en el Esqueleto

    Energy Technology Data Exchange (ETDEWEB)

    Maletskos, C. J.; Braun, A. G.; Shanahan, M. M.; Evans, R. D. [Radioactivity Center, Department of Physics. Massachusetts Institute of Technology, Cambridge, MA (United States)

    1964-11-15

    Utah. Further analysis is indicated. No clinically significant signs or symptoms are observed at MPRE < 0.5 {mu}c. In the region 10{sup -3} to 10{sup -1} {mu}c MPRE the clinical data are in the normal range. (author) [French] Les 361 sujets ayant une charge squelettique de radium 226 et radium 228, qui ont ete examines au laboratoire oue travaillent les auteurs, constituent actuellement un echantillon assez important pour permettre l'evaluation quantitative de la relation entre la reponse biologique et la dose due a la contamination interne. Les auteurs decrivent les methodes utilisees pour une telle analyse et les resultats obtenus. Les reponses biologiques consistent en une variete de resultats cliniques tels que les radiogrammes obtenus, les tumeurs, les fractures, les analyses d'urine, l'hematologie, la chimie du sang et l'electrophorese des proteines. La dose due a la contamination interne est calculee et exprimee par la charge corporelle retenue, en microcuries d'equivalent minimum de radium 226 pur, en rads cumulatifs et en rad-annees cumulatifs. Dans la premiere phase de l'analyse, on determine s'il existe une relation entre un parametre clinique et la dose. On fait cette determination en recourant a un test de-contingence, permettant de comparer les donnees reelles et un modele d'independance entre les deux variables que l'on considere comme possible. Si l'on trouve qu'il n'y a pas d'independance, on fait une hypothese relative a,la relation qui existe et on obtient une description quantitative de la dependance. On fait un ajustement par la methode des moindres carres pour calculer les coefficients et les ecarts types des coefficients d'un developpement en serie. Une telle expression fournit une description quantitative empirique des resultats en meme temps qu'une mesure de leur variabilite, elle est utile pour une comparaison impartiale avec les resultats des autres laboratoires, mais n'implique aucun mecanisme biophysique. Les auteurs ont compare les

  8. Doses de enxofre e tempo de incubação na dinâmica de formas de enxofre no solo

    Directory of Open Access Journals (Sweden)

    Sandra Cátia Pereira Uchôa

    2013-06-01

    Full Text Available A disponibilidade de enxofre (S depende da dinâmica de suas formas no solo. Visando estudar o equilíbrio entre as reservas de S lábil e S não lábil, amostras de 10 solos foram incubadas com cinco doses de sulfato de cálcio (0, 20, 50, 80 e 120 mg dm-3 de S, durante 1, 8, 15, 30, 60 e 90 d. Para a determinação do S lábil, utilizou-se membrana de resina de troca aniônica em forma de lâmina. O S extraído com 48 h de agitação foi denominado de enxofre rapidamente lábil (SRL. O teor obtido com tempo de agitação superior a 48 h foi denominado de enxofre lentamente lábil e o não lábil (SLL+SNL, pela diferença entre o S do solo (extraído após calcinação e SRL. A resistência que o solo oferece à passagem do S da reserva do SRL para a do SLL+SNL foi denominada de capacidade-tampão do S lábil (CTSL, sendo obtida pelo inverso do coeficiente angular das equações lineares do teor de SRL em função do teor de SLL+SNL. Constatou-se que tempo de incubação (reatividade e as doses de S, na forma de sulfato de cálcio, influenciam a dinâmica do S entre as reservas de SRL e SLL+SNL. A CTSL é sensível às mudanças no equilíbrio entre as reservas de S no solo. O aumento da CTSL dos solos relacionou-se, principalmente, com a capacidade máxima de adsorção de sulfato, teor de carbono orgânico, goethita e gibbsita da fração argila dos solos estudados.

  9. Crescimento de mudas de pinhão-manso em resposta a adubação com superfosfato simples e pó-de-rocha Growth of jatropha seedlings in response to single superphosphate and rock-flour fertilization

    Directory of Open Access Journals (Sweden)

    Fabiano Barbosa de Souza Prates

    2012-06-01

    Full Text Available Pesquisas feitas com pó-de-rocha têm mostrado a potencialidade de alguns desses resíduos em promover o enriquecimento mineral de solos; prática definida como rochagem do solo. Ela visa aumentar a fertilidade do solo, proporcionar uma boa produtividade e maior sustentabilidade agrícola. O presente trabalho teve por objetivo avaliar o crescimento de mudas de pinhão-manso (Jatropha curcas L. em resposta a adubação do substrato com superfosfato simples e pó-de-rocha. O experimento foi instalado e conduzido no período de setembro a novembro de 2007, em casa de vegetação do Instituto de Ciências Agrárias/UFMG. Os tratamentos, em esquema fatorial 2 x 5, no delineamento em blocos casualizados, com 3 repetições, corresponderam a 2 doses de pó-de-rocha (0 e 20 kg m-3 de substrato e 5 doses de superfosfato simples (1,25; 2,5; 5,0; 7,5 e 10,0 kg m-3 de substrato. Foram avaliados: altura da planta, diâmetro do caule, relação altura da planta/diâmetro do caule, número de folhas por planta, área foliar, matéria fresca e seca da raiz e da parte aérea, matéria fresca e seca total, relação matéria seca da parte aérea/matéria seca da raiz e índice de qualidade de Dickson IQD. Os resultados mostram que não houve interação significativa entre as doses de fósforo e a de pó-de-rocha aplicadas e as variáveis estudadas. A aplicação de superfosfato simples foi significativa para altura da planta, diâmetro do caule, área foliar, matéria fresca da raiz, da parte aérea e total, respondendo positivamente até a dose máxima de fósforo aplicada.Research into rock-flour have shown the potential of some of these residues in promoting the mineral enrichment of soils; a practice defined as stonemeal soil. Such practice aims to increase soil fertility and provide good productivity and greater agricultural sustainability. The present study had as objective to evaluate the growth of jatropha seedlings (Jatropha curcas L. in response to

  10. Determination of dose rates in beta radiation fields using extrapolation chamber and GM counter

    International Nuclear Information System (INIS)

    Borg, J.; Christensen, P.

    1995-01-01

    The extrapolation chamber measurement method is the basic method for the determination of dose rates in beta radiation fields and the method has been used for the establishment of beta calibration fields. The paper describes important details of the method and presents results from the measurements of depth-dose profiles from different beta radiation fields with E max values down to 156 keV. Results are also presented from studies of GM counters for use as survey instruments for monitoring beta dose rates at the workplace. Advantages of GM counters are a simple measurement technique and high sensitivity. GM responses were measured from exposures in different beta radiation fields using different filters in front of the GM detector and the paper discusses the possibility of using the results from GM measurements with two different filters in an unknown beta radiation field to obtain a value of the dose rate. (Author)

  11. Consumo de álcool e violência entre adolescentes argentinos

    Directory of Open Access Journals (Sweden)

    Mariaelena Pierobon

    2013-02-01

    Full Text Available OBJETIVO: Este estudo investigou a associação entre álcool e violência na população de jovens argentinos. MÉTODOS: Dados da Global School-based Student Health Survey (GSHS de 2007, uma pesquisa representativa em termos nacionais com alunos do ensino médio, foram examinados utilizando-se modelos de regressão logística ajustados por idade. RESULTADOS: Dos 1328 alunos participantes entre 13 e 15 anos de idade, 51,9% declararam ter consumido álcool no último mês, com taxas mais elevadas entre meninos (p = 0,04 e alunos mais velhos (p < 0,01. Homens e mulheres que bebem demonstraram estar quase duas vezes mais propensos a relatar agressão física, quando em uma briga física, e pensamentos sobre violência autoinfligida do que aqueles que não bebem. Entre as pessoas que bebem, aquelas que reportaram saúde mental precária, haviam sido vítimas de bullying, fumavam, faziam uso de drogas ou abandonaram a escola sem permissão se mostraram duas vezes mais propensas ao envolvimento em atividades violentas do que outras pessoas que também bebem. CONCLUSÃO: Intervenções de saúde pública quanto à violência entre jovens adolescentes devem ser desenvolvidas em combinação com programas de educação sobre álcool.

  12. Analyse de régression quantile de la relation entre la langue et l’intervalle entre les grossesses au Québec (Canada

    Directory of Open Access Journals (Sweden)

    Nathalie Auger

    2018-01-01

    Full Text Available Introduction. On sait que les intervalles courts comme les intervalles longs entre les grossesses sont associés à des issues périnatales défavorables, comme des fausses couches et des accouchements prématurés, mais les différences culturelles à ce sujet sont mal connues. Repérer les inégalités culturelles dans les intervalles entre les grossesses est nécessaire afin d'améliorer les résultats relatifs à la santé de la mère et de l’enfant. Nous avons ainsi évalué les intervalles entre les grossesses chez les anglophones et les francophones du Québec. Méthodologie. Nous avons obtenu les dossiers de naissance de tous les enfants nés au Québec entre 1989 et 2011. Nous avons recensé 571 461 femmes ayant eu au moins deux naissances et déterminé l’intervalle entre leurs grossesses. Les intervalles courts entre les grossesses (moins de 18 mois ont été définis comme étant le 20e percentile de la distribution, et les intervalles longs (60 mois ou plus, comme le 80e percentile. À l’aide de régressions quantiles, nous avons évalué l’association entre la langue et les intervalles courts et longs, ajustés en fonction des caractéristiques de la mère. Nous avons évalué les différences au fil du temps et selon l’âge de la mère pour les groupes défavorisés, qui ont été définis par l’absence de diplôme d’études secondaires, la résidence en milieu rural et le fait de vivre dans un quartier défavorisé matériellement. Résultats. Dans les modèles de régression ajustés, les anglophones sans diplôme d’études secondaires avaient des intervalles plus courts de 1,0 mois (intervalle de confiance [IC] à 95 % : −1,5 à −0,4 par rapport à leurs homologues francophones au 20e percentile de la distribution et plus longs de 1,9 mois (−0,5 à 4,3 au 80e percentile. Les résultats étaient similaires pour les anglophones des régions rurales et des quartiers matériellement défavorisés. Les

  13. Simples Nacional no Brasil: o difícil balanço entre estímulos às pequenas empresas e aos gastos tributários

    Directory of Open Access Journals (Sweden)

    Nelson Leitão Paes

    2014-12-01

    Full Text Available As microempresas e as pequenas empresas (MPEs brasileiras possuem alta representatividade na economia, principalmente no tocante à oferta de empregos. Trata-se de um grupo expressivo e que apresenta uma série de singularidades no que diz respeito à tributação. Em razão de serem pequenas, elas podem incorrer em custos econômicos superiores ao das maiores empresas. Nesse sentido, muitos países têm buscado criar mecanismos específicos de apoio às MPEs. Com o Simples Nacional, o Brasil concedeu uma série de benefícios fiscais e simplificações administrativas para as microempresas e as pequenas empresas. A arrecadação do Simples Nacional cresceu a taxas muito superiores a de todos os demais tributos, tendo sido três vezes maior do que a taxa real de crescimento de toda a arrecadação. O valor arrecadado por estabelecimento cresceu expressivamente durante a vigência do Simples Nacional, corroborando a evidência de que houve forte crescimento das empresas optantes pelo novo regime. O crescimento da arrecadação trouxe como contrapartida o incremento das renúncias fiscais, que cresceram a taxas ainda maiores do que o aumento da arrecadação.

  14. Application of biological effective dose (BED) to estimate the duration of symptomatic relief and repopulation dose equivalent in palliative radiotherapy and chemotherapy

    International Nuclear Information System (INIS)

    Jones, Bleddyn; Cominos, Matilda; Dale, Roger G.

    2003-01-01

    Purpose: To investigate the potential for mathematic modeling in the assessment of symptom relief in palliative radiotherapy and cytotoxic chemotherapy. Methods: The linear quadratic model of radiation effect with the overall treatment time and the daily dose equivalent of repopulation is modified to include the regrowth time after completion of therapy. Results: The predicted times to restore the original tumor volumes after treatment are dependent on the biological effective dose (BED) delivered and the repopulation parameter (K); it is also possible to estimate K values from analysis of palliative treatment response durations. Hypofractionated radiotherapy given at a low total dose may produce long symptom relief in slow-growing tumors because of their low α/β ratios (which confer high fraction sensitivity) and their slow regrowth rates. Cancers that have high α/β ratios (which confer low fraction sensitivity), and that are expected to repopulate rapidly during therapy, are predicted to have short durations of symptom control. The BED concept can be used to estimate the equivalent dose of radiotherapy that will achieve the same duration of symptom relief as palliative chemotherapy. Conclusion: Relatively simple radiobiologic modeling can be used to guide decision-making regarding the choice of the most appropriate palliative schedules and has important implications in the design of radiotherapy or chemotherapy clinical trials. The methods described provide a rationalization for treatment selection in a wide variety of tumors

  15. The influence of dose per fraction on repair kinetics

    International Nuclear Information System (INIS)

    Rojas, A.; Joiner, M.C.

    1989-01-01

    The use of multiple fractions per day (MFD) in radiotherapy requires information about the rate of repair of radiation injury. It is important to know the minimum interval between fractions necessary for maximum sparing of normal tissue damage, whether rate of repair is dependent on the size of dose per fraction and if it is different in early and late responding tissues and in tumours. To address these questions, the rate of repair between radiation dose fractions was measured in mouse skin (acute damage), mouse kidney (late damage) and a mouse tumour (carcinoma NT). Skin and kidney measurements were made using multiple split doses of X-rays, followed by a neutron top-up. For skin, faster recovery was obtained with 4.4 Gy fractions (t1/2 = 3.46 ± 0.88 h). In contrast kidney showed slower recovery at a low dose per fraction of 2 Gy (t1/2 = 1.69 ± 0.39 h) than at a higher dose of 7 Gy per fraction (t1/2 = 0.92 ± 0.1h). These data show that repair rate is dependent on the size of dose per fraction, but not in a simple way. T1/2 values now available for many different tissues generally lie in the range of 1-2h, and are not correlated with proliferation status or early versus late response to treatment. At the doses used currently in clinical MFD treatments, these data indicate that damage in almost all normal tissues would increase if interfraction intervals less than 6 h were used. The t1/2 for CaNT (0.31 ± 0.15 h) is less than for any normal tissue. This underlines that the excess morbidity resulting from interfraction intervals < 6 h will not be paralleled by an increased effect in tumours. (author). 25 refs.; 7 figs

  16. From personnel dose to personal dose

    International Nuclear Information System (INIS)

    Hoefert, M.; Raffnsoe, R.C.; Tuyn, J.W.N.; Wittekind, D.

    1985-01-01

    From following the development of personnel doses at CERN over the past six years it has become evident that work in areas of induced radioactivity is the principal cause of exposure. The results of photon dose measurements free-in-air and around a phantom are presented and discussed in the light of new quantities in individual monitoring. The importance of these results, with respect to the practical situation, is discussed and the problem of phantom size is mentioned. Finally, the results of dose measurements in the phantom are presented, since such information is important in cases where it becomes necessary to transform personnel doses into personal doses. (author)

  17. SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

    Energy Technology Data Exchange (ETDEWEB)

    Pham, R; Sun, B; Zhao, T; Li, H; Yang, D; Grantham, K; Goddu, S; Santanam, L; Bradley, J; Mutic, S; Kandlakunta, P; Zhang, T [Washington University School of Medicine, Saint Louis, MO (United States)

    2016-06-15

    Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculated on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.

  18. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  19. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  20. Dose conversion coefficients for electron exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G; Zankl, M

    2009-01-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H p (0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H p (3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 deg. and 45 deg. are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  1. Soporte social, familiar y autoconcepto: relación entre los constructos

    Directory of Open Access Journals (Sweden)

    Makilim Nunes Baptista

    2012-01-01

    Full Text Available El objetivo del estudio fue verificar las asociaciones entre el soporte social, el soporte familiar y el autoconcepto en un grupo de hombres y mujeres. En el caso de los hombres hubo correlaciones negativas entre el soporte familiar y los factores negligencia, agresividad e indiferencia del instrumento de autoconcepto. En el grupo de mujeres el soporte familiar total fue correlacionado positivamente con sensualidad y responsabilidad, y negativamente con inseguridad, siendo las tres medidas del instrumento de autoconcepto. Al considerar las relaciones entre el soporte familiar y el soporte social, todas fueron positivas, tanto en los hombres como en las mujeres.

  2. A comparison of simple and realistic eye models for calculation of fluence to dose conversion coefficients in a broad parallel beam incident of protons

    International Nuclear Information System (INIS)

    Sakhaee, Mahmoud; Vejdani-Noghreiyan, Alireza; Ebrahimi-Khankook, Atiyeh

    2015-01-01

    Radiation induced cataract has been demonstrated among people who are exposed to ionizing radiation. To evaluate the deterministic effects of ionizing radiation on the eye lens, several papers dealing with the eye lens dose have been published. ICRP Publication 103 states that the lens of the eye may be more radiosensitive than previously considered. Detailed investigation of the response of the lens showed that there are strong differences in sensitivity to ionizing radiation exposure with respect to cataract induction among the tissues of the lens of the eye. This motivated several groups to look deeper into issue of the dose to a sensitive cell population within the lens, especially for radiations with low energy penetrability that have steep dose gradients inside the lens. Two sophisticated mathematical models of the eye including the inner structure have been designed for the accurate dose estimation in recent years. This study focuses on the calculations of the absorbed doses of different parts of the eye using the stylized models located in UF-ORNL phantom and comparison with the data calculated with the reference computational phantom in a broad parallel beam incident of protons with energies between 20 MeV and 10 GeV. The obtained results indicate that the total lens absorbed doses of reference phantom has good compliance with those of the more sensitive regions of stylized models. However, total eye absorbed dose of these models greatly differ with each other for lower energies. - Highlights: • The validation of reference data for the eye was studied for proton exposures. • Two real mathematical models of the eye were imported into the UF-ORNL phantom. • Fluence to dose conversion coefficients were calculated for different eye sections. • Obtained Results were compared with that of assessed by ICRP adult male phantom

  3. PENGARUH PANJANG ENTRES TERHADAP KEBERHASILAN PENYAMBUNGAN TANAMAN ALPUKAT (PERSEA AMERICANA MILL.

    Directory of Open Access Journals (Sweden)

    Dirgahani Putri

    2016-06-01

    Full Text Available Beragamnya hasil produksi dan kualitas buah alpukat dapat diperbaiki dengan metode penyambungan. Penyambungan merupakan kegiatan untuk mengga-bungkan dua atau lebih sifat unggul dalam satu tanaman. Penelitian ini bertujuan mengetahui pengaruh berbagai panjang entres terhadap keberhasilan penyam-bungan tanaman alpukat. Rancangan percobaan yang digunakan dalam penelitian ini adalah Rancangan Acak Kelompok dengan lima perlakuan panjang entres, yaitu 3 cm, 6 cm, 9 cm, 12 cm, dan 15 cm.Setiap perlakuan diulang sebanyak lima kali dan setiap perlakuan terdiri atas lima tanaman;sehingga jumlah totalnya sebanyak 125 tanaman. Pengamatan dilakukan pada peubah persentase sambung hidup, jumlah tunas, panjang tunas, jumlah daun, dan diameter batang atas. Berbagai panjang entres tidak memberikan pengaruh yang nyata pada peubah persentase sambung hidup, panjang tunas terpanjang, jumlah daun, dan diameter batang atas tetapi berpengaruh nyata pada peubah jumlah tunas. Perlakuan panjang entres 15 cm memberikan hasil tertinggi untuk jumlah tunas, panjang tunas, jumlah daun dan diameter batang atas, sedangkan untuk persentase hidup perlakuan 6 cm, 12 cm memberikan hasil tertinggi yaitu 100%. Perlakuan panjang entres 3 cm adalah perlakuan yang memberikan pengaruh yang rendah pada persentase sambung hidup (yaitu 92%, peubah jumlah tunas, panjang tunas, serta diameter batang atas pada berbagai umur tanaman alpukat.

  4. Aborto entre alunas e funcionárias de uma universidade brasileira

    Directory of Open Access Journals (Sweden)

    Hardy Ellen

    1993-01-01

    Full Text Available No Brasil existem poucas informações sobre o aborto provocado e suas características na população. A dificuldade em se obter dados confiáveis deve-se: à sua ilegalidade, e também ao fato de que a maioria dos estudos é realizada em hospitais. Assim, em 1990, foi realizada pesquisa entre alunas da graduação e funcionárias de uma universidade brasileira. Os dados foram obtidos por meio de questionário, auto-respondido, para devolução por correio, anonimamente. Os resultados apresentados referem-se à freqüência do aborto provocado nesta população. Encontrou-se que quatro vezes menos alunas do que funcionárias tinham engravidado alguma vez (15% e 65%; 9% das alunas e 14% das funcionárias tiveram aborto provocado. Entre as mulheres que engravidaram alguma vez, as alunas tiveram mais aborto provocado do que as funcionárias (59% e 20%. Quando controladas por grupo etário as diferenças entre as alunas e funcionárias mantiveram-se. Entretanto, entre as alunas, o aborto provocado foi mais freqüente entre as mais jovens.

  5. Current algorithms for computed electron beam dose planning

    International Nuclear Information System (INIS)

    Brahme, A.

    1985-01-01

    Two- and sometimes three-dimensional computer algorithms for electron beam irradiation are capable of taking all irregularities of the body cross-section and the properties of the various tissues into account. This is achieved by dividing the incoming broad beams into a number of narrow pencil beams, the penetration of which can be described by essentially one-dimensional formalisms. The constituent pencil beams are most often described by Gaussian, experimentally or theoretically derived distributions. The accuracy of different dose planning algorithms is discussed in some detail based on their ability to take the different physical interaction processes of high energy electrons into account. It is shown that those programs that take the deviations from the simple Gaussian model into account give the best agreement with experimental results. With such programs a dosimetric relative accuracy of about 5% is generally achieved except in the most complex inhomogeneity configurations. Finally, the present limitations and possible future developments of electron dose planning are discussed. (orig.)

  6. Computerized simulation methods for dose reduction, in radiodiagnosis

    International Nuclear Information System (INIS)

    Brochi, M.A.C.

    1990-01-01

    The present work presents computational methods that allow the simulation of any situation encountered in diagnostic radiology. Parameters of radiographic techniques that yield a standard radiographic image, previously chosen, and so could compare the dose of radiation absorbed by the patient is studied. Initially the method was tested on a simple system composed of 5.0 cm of water and 1.0 mm of aluminium and, after verifying experimentally its validity, it was applied in breast and arm fracture radiographs. It was observed that the choice of the filter material is not an important factor, because analogous behaviours were presented by aluminum, iron, copper, gadolinium, and other filters. A method of comparison of materials based on the spectral match is shown. Both the results given by this simulation method and the experimental measurements indicate an equivalence of brass and copper, both more efficient than aluminium, in terms of exposition time, but not of dose. (author)

  7. Radiation dose reduction on multidetector abdominal CT using adaptive statistical iterative reconstruction technique in children

    International Nuclear Information System (INIS)

    Zhang Qifeng; Peng Yun; Duan Xiaomin; Sun Jihang; Yu Tong; Han Zhonglong

    2013-01-01

    Objective: To investigate the feasibility to reduce radiation doses on pediatric multidetector abdominal CT using the adaptive statistical iterative reconstruction technique (ASIR) associated with automated tube current modulation technique (ATCM). Methods: Thirty patients underwent abdominal CT with ATCM and the follow-up scan with ATCM cooperated with 40% ASIR. ATCM was used with age dependent noise index (NI) settings: NI = 9 for 0-5 year old and NI = 11 for > 5 years old for simple ATCM group, NI = 11 for 0-5 year old and NI = 15 for > 5 years old for ATCM cooperated with 40% ASIR group (AISR group). Two radiologists independently evaluated images for diagnostic quality and image noise with subjectively image quality score and image noise score using a 5-point scale. Interobserver agreement was assessed by Kappa test. The volume CT dose indexes (CTDIvol) for the two groups were recorded. Statistical significance for the CTDIvol value was analyzed by pair-sample t test. Results: The average CTDIvol for the ASIR group was (1.38 ± 0.64) mGy, about 60% lower than (3.56 ± 1.23) mGy for the simple ATCM group, and the CTDIvol of two groups had statistically significant differences. (t = 33.483, P < 0.05). The subjective image quality scores for the simple ATCM group were 4.43 ± 0.57 and 4.37 ±0.61, Kappa = 0.878, P < 0.01 (ASIR group: 4.70 ± 0.47 and 4.60 ± 0.50, Kappa = 0.783, P < 0.01), by two observers. The image noise score for the simple ATCM group were 4.03 ±0.56 and 3.83 ±0.53, Kappa = 0.572, P < 0.01 (ASIR group: 4.20 ± 0.48 and 4.10 ± 0.48, Kappa = 0.748, P < 0.01), by two observers. All images had acceptable diagnostic image quality. Conclusion: Lower radiation dose can be achieved by elevating NI with ASIR in pediatric CT abdominal studies, while maintaining diagnostically acceptable images. (authors)

  8. Patient dose map indications on interventional X-ray systems and validation with Gafchromic XR-RV3 film

    International Nuclear Information System (INIS)

    Bordier, C.; Klausz, R.; Desponds, L.

    2015-01-01

    To help avoiding secondary effects of interventional procedures like skin damage, a dose map method has been developed to provide an indication of the local dose on a surface representative of individual patient shapes. To minimise user interactions, patient envelope shapes are automatically determined depending on simple patient data information. Local doses are calculated in 1-cm 2 areas depending on the estimated air kerma, table and gantry positions and system settings, taking into account the table and mattress attenuations and estimated backscatter from the patient. These local doses are cumulated for each location of the patient envelope during the clinical procedure. To assess the accuracy of the method, Gafchromic XR-RV3 films have been used in several operating configurations. Good visual agreements on cumulated dose localisation were obtained within the 1-cm 2 precision of the map and the dose values agreed within 24.9 % accuracy. The resulting dose map method has been integrated into GE Healthcare X-Ray angiographic systems and should help in the management of the dose by the users during the procedure. (authors)

  9. Produtividade de brócolis de verão com diferentes doses de bokashi

    Directory of Open Access Journals (Sweden)

    Sindynara Ferreira

    2013-09-01

    Full Text Available O plantio de brócolis tipo cabeça única vem se expandindo nos últimos anos. A procura por alimentos mais saudáveis tem causado um aumento na utilização de compostos orgânicos enriquecidos com microrganismos, e entre estes, destaca-se o bokashi. O objetivo deste trabalho foi avaliar o comportamento da cultivar de brócolis de cabeça única Lord Summer sob diferentes doses do composto orgânico bokashi. O delineamento utilizado foi o de blocos casualizados com quatro repetições e cinco doses do composto (0; 250; 500; 750; 1000 g.m-2. Houve resposta linear para as características altura de plantas, número de folhas por planta, diâmetro do caule e cabeça e massa média de cabeça. Em sistema orgânico a melhor dosagem de bokashi para a cultivar Lord Sumer correspondeu a 1000 g.m-2 porém, a ausência de um ponto de máxima em todas características avaliadas, sugere que doses mais elevadas de bokashi poderiam resultar em maiores valores.

  10. Determination of dose rates in beta radiation fields using extrapolation chamber and GM counter

    DEFF Research Database (Denmark)

    Borg, J.; Christensen, P.

    1995-01-01

    of depth-dose profiles from different beta radiation fields with E(max) values down to 156 keV. Results are also presented from studies of GM counters for use as survey instruments for monitoring beta dose rates at the workplace. Advantages of GM counters are a simple measurement technique and high...... sensitivity. GM responses were measured from exposures in different beta radiation fields using different filters in front of the GM detector and the paper discusses the possibility of using the results from GM measurements with two different filters in an unknown beta radiation field to obtain a value...

  11. Methods for estimation of internal dose of the public from dietary

    International Nuclear Information System (INIS)

    Zhu Hongda

    1987-01-01

    Following the issue of its Publication 26, ICRP has successively published its Publication 30 to meet the great changes and improvements made in the Basic Recommendations since July of 1979. In Part 1 of Publcation 30, ICRP recommended a new method for internal dose estimation and pressented some important data. In this report, comparison is made among methods for estimation of internal dose for the public from dietary. They include: (1) the new method suggested by ICRP; (2) the simple and convenient method using transfer factors under equilibrium conditions; (3) the methods based on the similarities of several radionuclides to their chemical analogs. It is concluded that the first method is better than the others and should be used from now on

  12. Simple arithmetic: not so simple for highly math anxious individuals.

    Science.gov (United States)

    Chang, Hyesang; Sprute, Lisa; Maloney, Erin A; Beilock, Sian L; Berman, Marc G

    2017-12-01

    Fluency with simple arithmetic, typically achieved in early elementary school, is thought to be one of the building blocks of mathematical competence. Behavioral studies with adults indicate that math anxiety (feelings of tension or apprehension about math) is associated with poor performance on cognitively demanding math problems. However, it remains unclear whether there are fundamental differences in how high and low math anxious individuals approach overlearned simple arithmetic problems that are less reliant on cognitive control. The current study used functional magnetic resonance imaging to examine the neural correlates of simple arithmetic performance across high and low math anxious individuals. We implemented a partial least squares analysis, a data-driven, multivariate analysis method to measure distributed patterns of whole-brain activity associated with performance. Despite overall high simple arithmetic performance across high and low math anxious individuals, performance was differentially dependent on the fronto-parietal attentional network as a function of math anxiety. Specifically, low-compared to high-math anxious individuals perform better when they activate this network less-a potential indication of more automatic problem-solving. These findings suggest that low and high math anxious individuals approach even the most fundamental math problems differently. © The Author (2017). Published by Oxford University Press.

  13. The effects of simulating a realistic eye model on the eye dose of an adult male undergoing head computed tomography.

    Science.gov (United States)

    Akhlaghi, Parisa; Ebrahimi-Khankook, Atiyeh; Vejdani-Noghreiyan, Alireza

    2017-05-01

    In head computed tomography, radiation upon the eye lens (as an organ with high radiosensitivity) may cause lenticular opacity and cataracts. Therefore, quantitative dose assessment due to exposure of the eye lens and surrounding tissue is a matter of concern. For this purpose, an accurate eye model with realistic geometry and shape, in which different eye substructures are considered, is needed. To calculate the absorbed radiation dose of visual organs during head computed tomography scans, in this study, an existing sophisticated eye model was inserted at the related location in the head of the reference adult male phantom recommended by the International Commission on Radiological Protection (ICRP). Then absorbed doses and distributions of energy deposition in different parts of this eye model were calculated and compared with those based on a previous simple eye model. All calculations were done using the Monte Carlo code MCNP4C for tube voltages of 80, 100, 120 and 140 kVp. In spite of the similarity of total dose to the eye lens for both eye models, the dose delivered to the sensitive zone, which plays an important role in the induction of cataracts, was on average 3% higher for the sophisticated model as compared to the simple model. By increasing the tube voltage, differences between the total dose to the eye lens between the two phantoms decrease to 1%. Due to this level of agreement, use of the sophisticated eye model for patient dosimetry is not necessary. However, it still helps for an estimation of doses received by different eye substructures separately.

  14. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A. Joe [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G., E-mail: PMaxim@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2017-01-01

    Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.

  15. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator.

    Science.gov (United States)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A Joe; Loo, Billy W; Maxim, Peter G

    2017-01-01

    A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, "FLASH") potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Encuentros improbables: Cervantes y Shakespeare entre Borges y Burgess

    OpenAIRE

    Martínez, Zenón Luis

    2016-01-01

    En sus biografías sobre Cervantes y Shakespeare, Luis Astrana Marín especuló con un encuentro entre ambos con ocasión de la ratificación en 1605 en Valladolid del Tratado de Londres. Este improbable encuentro ha seguido alimentando ficciones históricas y fantasías literarias. El cruce de caminos entre Cervantes y Shakespeare tiene lugar en torno a la perdida tragicomedia The History of Cardenio (1612?), atribuida a John Fletcher y William Shakespeare. La recon...

  17. Mixed Beam Murine Harderian Gland Tumorigenesis: Predicted Dose-Effect Relationships if neither Synergism nor Antagonism Occurs

    Energy Technology Data Exchange (ETDEWEB)

    Siranart, Nopphon; Blakely, Eleanor A.; Cheng, Alden; Handa, Naval; Sachs, Rainer K.

    2016-12-01

    Complex mixed radiation fields exist in interplanetary space, and not much is known about their latent effects on space travelers. In silico synergy analysis default predictions are useful when planning relevant mixed-ion-beam experiments and interpreting their results. These predictions are based on individual dose-effect relationships (IDER) for each component of the mixed-ion beam, assuming no synergy or antagonism. For example, a default hypothesis of simple effect additivity has often been used throughout the study of biology. However, for more than a century pharmacologists interested in mixtures of therapeutic drugs have analyzed conceptual, mathematical and practical questions similar to those that arise when analyzing mixed radiation fields, and have shown that simple effect additivity often gives unreasonable predictions when the IDER are curvilinear. Various alternatives to simple effect additivity proposed in radiobiology, pharmacometrics, toxicology and other fields are also known to have important limitations. In this work, we analyze upcoming murine Harderian gland (HG) tumor prevalence mixed-beam experiments, using customized open-source software and published IDER from past single-ion experiments. The upcoming experiments will use acute irradiation and the mixed beam will include components of high atomic number and energy (HZE). We introduce a new alternative to simple effect additivity, "incremental effect additivity", which is more suitable for the HG analysis and perhaps for other end points. We use incremental effect additivity to calculate default predictions for mixture dose-effect relationships, including 95% confidence intervals. We have drawn three main conclusions from this work. 1. It is important to supplement mixed-beam experiments with single-ion experiments, with matching end point(s), shielding and dose timing. 2. For HG tumorigenesis due to a mixed beam, simple effect additivity and incremental effect additivity sometimes give

  18. Measurement of spatial dose-rate distribution using a position sensitive detector

    International Nuclear Information System (INIS)

    Emoto, T.; Torii, T.; Nozaki, T.; Ando, H.

    1994-01-01

    Recently, the radiation detectors using plastic scintillation fibers (PSF) have been developed to measure the positions exposed to radiation such as neutrons and high energy charged particles. In particular, the time of flight (TOF) method for measuring the difference of time that two directional signals of scintillation light reach both ends of a PSF is a rather simple method for the measurement of the spatial distribution of fast neutron fluence rate. It is possible to use the PSF in nuclear facility working areas because of its flexibility, small diameter and long length. In order to apply TOF method to measure spatial gamma dose rate distribution, the characteristic tests of a detector using PSFs were carried out. First, the resolution of irradiated positions and the counting efficiency were measured with collimated gamma ray. The sensitivity to unit dose rate was also obtained. The measurement of spatial dose rate distribution was also carried out. The sensor is made of ten bundled PSFs, and the experimental setup is described. The experiment and the results are reported. It was found that the PSF detector has the good performance to measure spatial gamma dose rate distribution. (K.I.)

  19. La religiosidad popular como “entre-medio” entre la religión institucional y la espiritualidad individualizada = Popular religion as “in between” institutional religion and individual spirituality

    Directory of Open Access Journals (Sweden)

    Torre, Renée de la

    2012-01-01

    Full Text Available Neste artigo se argumenta a relevância do estudo da religiosidade popular para entender as novas formas da religiosidade contemporânea no contexto latinoamericano. Diferente das posturas teóricas dos sociólogos da religião europeia, que assinalam a pertinência do indivíduo como unidade analítica para entender as transformações religiosas próprias da pós-modernidade, este artigo argumenta que a religiosidade popular – entendida como “entre-meio” entre o tradicional e o emergente, entre o local e o transnacional, entre o social e o individual e entre a sacralidade profana e a profanação da religiosidade tradicional – permite entender os fenômenos em que a religiosidade se pratica nas margens da instituição (próprias das expressões new age e neoesotéricas, mas sem desatender os processos em que se legitimam as novas formas desinstitucionalizadas da religiosidade, buscando âncoras e linhagens que geram a continuidade do peso da tradição da religiosidade popular

  20. Relación entre calidad del semen y la edad

    Directory of Open Access Journals (Sweden)

    John Chávez

    2012-07-01

    Full Text Available Objetivo: Determinar la relación entre la calidad del semen humano y la edad. Material y Métodos: El espermatograma se realizó siguiendo el Manual de Laboratorio de la OMS para el examen del Semen Humano y de la Interacción Moco Cervical y Semen (1999, de los exámenes realizados entre julio 2003 a diciembre 2008. Se estudiaron 2 441 casos de varones que cumplen con los criterios de inclusión. Resultados: La motilidad A+B fue de 51,55% para varones de 20 a 29 años; los espermatozoides normales fue de 77,73% para varones mayores de 50 años; el recuento espermático (mill/ml fue de 61,09 para varones mayores de 50 años.La evaluación de la motilidad espermática tuvo como coeficiente de correlación lineal múltiple de 0,222 y coeficiente de determinación de 0,049; en la morfología espermática, coeficiente de correlación lineal de 0,0622 y coeficiente de determinación de 0,0039; en el recuento espermático, coeficiente de correlación lineal múltiple de 0,465 y coeficiente de determinación de 0,216. Conclusiones: existe una tendencia inversa entre la motilidad y la edad, una tendencia directa entre el recuento espermático y la edad, y una tendencia constante entre morfología espermática y edad.

  1. relaPro : Base de datos para encontrar relaciones entre proyectos

    OpenAIRE

    Fortis Urbano, Julio

    2015-01-01

    Desarrollo de una base de datos para almacenar proyectos y una aplicación web de ejemplo que permite encontrar elementos comunes entre los proyectos almacenados en el sistema. Desenvolupament d'una base de dades per emmagatzemar projectes i una aplicació web d'exemple que permet trobar elements comuns entre els projectes emmagatzemats en el sistema. Bachelor thesis for the Computer Science program on Databases.

  2. Mechanistic simulation of normal-tissue damage in radiotherapy-implications for dose-volume analyses

    International Nuclear Information System (INIS)

    Rutkowska, Eva; Baker, Colin; Nahum, Alan

    2010-01-01

    A radiobiologically based 3D model of normal tissue has been developed in which complications are generated when 'irradiated'. The aim is to provide insight into the connection between dose-distribution characteristics, different organ architectures and complication rates beyond that obtainable with simple DVH-based analytical NTCP models. In this model the organ consists of a large number of functional subunits (FSUs), populated by stem cells which are killed according to the LQ model. A complication is triggered if the density of FSUs in any 'critical functioning volume' (CFV) falls below some threshold. The (fractional) CFV determines the organ architecture and can be varied continuously from small (series-like behaviour) to large (parallel-like). A key feature of the model is its ability to account for the spatial dependence of dose distributions. Simulations were carried out to investigate correlations between dose-volume parameters and the incidence of 'complications' using different pseudo-clinical dose distributions. Correlations between dose-volume parameters and outcome depended on characteristics of the dose distributions and on organ architecture. As anticipated, the mean dose and V 20 correlated most strongly with outcome for a parallel organ, and the maximum dose for a serial organ. Interestingly better correlation was obtained between the 3D computer model and the LKB model with dose distributions typical for serial organs than with those typical for parallel organs. This work links the results of dose-volume analyses to dataset characteristics typical for serial and parallel organs and it may help investigators interpret the results from clinical studies.

  3. Personnel and patient doses: Are there ethical consequences to the use of X-rays?

    International Nuclear Information System (INIS)

    Faulkner, K.

    2005-01-01

    Interventional cardiology has witnessed a period of great technological change. The introduction of new dedicated cardiology X-ray equipment, as well as advances in catheter and stent design, has revolutionised clinical practice in cardiology. As a consequence, the number, range and complexity of procedures have increased. This has meant that patients can be treated as outpatients without requiring hospitalisation for surgery. The public are aware of these benefits and demand greater access. However, these changes have had an impact on patient and staff doses and these are reviewed. Simple approaches to dose reduction for patients and staff are illustrated. There are a number of ethical issues concerning both patients and staff. For patients, these are related to informed consent. For staff, the ethical issues are associated with dose control. These issues will be discussed. (authors)

  4. Assessment of medical staff radiation doses received in some interventional examination

    International Nuclear Information System (INIS)

    Oenal, E.

    2006-03-01

    The aim of this work is to suggest a simple method for the estimation of cardiologist extremity doses. The extremity and effective doses The extremity and effective doses of nine cardiologists working at five different angiographic units were measured for 157 interventional examinations. Simultaneous measurement of patient doses were also carried out using a DAP meter separately for each projection. Fluoroscopy time (T f l), number of radiographic frames (N) were recorded on-line during these measurements. A Rando phantom was exposed at similar projections with patient studies and one minute of fluoroscopic exposure (D 1 50 n T f l n ) and one frame of radiographic exposure (D 1 50 n N n ) were determined for each projection. Scatter radiations from these exposures were also measured at 50, 100 and 150 cm above the floor level at the cardiologist positions for the estimation of legs, wrists and thyroid (or eye) doses. Weighting of projections were determined for the patient group of each cardiologist using the recorded values of T f l and N r f. Extremity doses, D x were calculated with the following formula: D 1 50=Σ n D 1 50 n T f l n (T f l n )+Σ n D 1 50 n N n (N n ), n=4, 5, 6, 7, 10. n gives the projection numbert and x is the distance from the floor level. Measured and calculated extremity doses for each cardiologist were in good agreement. The calculated doses for 50cm and 100cm were found within the measured values of left and right legs and wrists. The use of dominant projection data alone still provided comparable results

  5. Simple instrument for biochemical studies of the living human brain

    International Nuclear Information System (INIS)

    Bice, A.N.; Wagner, H.N. Jr.; Lee, M.C.; Frost, J.J.

    1986-01-01

    A simple, relatively inexpensive radiation detection system was developed for measurement of positron-emitting receptor-binding drugs in the human brain. This high-efficiency coincidence counting system requires that only a few hundred microcuries of labeled drug be administered to the subject, thereby allowing for multiple studies without an excessive radiation dose. Measurement of the binding of [ 11 C]-carfentanil, a high-affinity synthetic opiate, to opiate receptors in the presence and in the absence of a competitive opiate antagonist exemplifies the use of this system for estimating different degrees of receptor binding of drugs in the human brain. The instrument has also been used for measurement of the transport into the brain of other positron-emitting radiotracers, such as large neutral amino acids

  6. Cooperación; altruismo en las relaciones entre aerolíneas

    OpenAIRE

    Fernández Lerate, Elisa M.

    2016-01-01

    El presente estudio se centra en analizar unas determinadas relaciones cooperativas entre compañías aéreas, con la intención de investigar si sacan provecho o no de dichas relaciones. La cooperación entre esas compañías aéreas puede presentar comportamientos más altruistas o más oportunistas. Para centrar el tema del estudio, se van a analizar los acuerdos de códigos compartidos que llevan a cabo entre ellas. Los datos de cooperación a través de código compartido permitirán conocer qué porcen...

  7. Efeito de doses de gesso agrícola na cultura do milho e alterações químicas no solo

    Directory of Open Access Journals (Sweden)

    Luiz Augusto Amaral

    2017-04-01

    Full Text Available A cultura do milho apresenta importância econômica no cenário agrícola, de modo que a região Centro Oeste detém a maior media de produtividade do Brasil. O objetivo deste estudo foi avaliar o efeito de doses de gesso agrícola sobre a produtividade de milho cultivado em segunda safra e seus efeitos químicos no solo. O experimento foi realizado no Campus experimental da UNEMAT, Tangará da Serra – MT. O delineamento experimental foi em blocos casualizados (DBC com cinco tratamentos (0 kg ha-1, 1.000 kg ha-1, 2.000 kg ha-1, 3.000 kg ha-1 e 4.000 kg ha-1 de gesso agrícola com quatro repetições, totalizando 20 parcelas. Foi utilizado o híbrido de milho DKB 390 VT Pro2, e as parcelas foram constituídas de cinco metros de comprimento por quatro de largura, com espaçamento entre linhas de 0,50 m. Foi aplicado calcário dolomítico e gesso agrícola aos 60 e 30 dias antes da semeadura, respectivamente. Somente a variável diâmetro do caule e produtividade apresentou diferença significativa entre os tratamentos, onde os diâmetros superiores foram observados nas doses acima 2.000 kg ha-1 e a maior produtividade obtida na dose de 4.000 kg ha-1 de gesso. O efeito da aplicação do gesso proporcionou aumento na concentração de enxofre, cálcio e magnésio no subsolo, assim como redução nos teores de alumino. A dose de 4.000 kg ha-1 de gesso promoveu a maior produtividade.

  8. Strategy as simple rules.

    Science.gov (United States)

    Eisenhardt, K M; Sull, D N

    2001-01-01

    The success of Yahoo!, eBay, Enron, and other companies that have become adept at morphing to meet the demands of changing markets can't be explained using traditional thinking about competitive strategy. These companies have succeeded by pursuing constantly evolving strategies in market spaces that were considered unattractive according to traditional measures. In this article--the third in an HBR series by Kathleen Eisenhardt and Donald Sull on strategy in the new economy--the authors ask, what are the sources of competitive advantage in high-velocity markets? The secret, they say, is strategy as simple rules. The companies know that the greatest opportunities for competitive advantage lie in market confusion, but they recognize the need for a few crucial strategic processes and a few simple rules. In traditional strategy, advantage comes from exploiting resources or stable market positions. In strategy as simple rules, advantage comes from successfully seizing fleeting opportunities. Key strategic processes, such as product innovation, partnering, or spinout creation, place the company where the flow of opportunities is greatest. Simple rules then provide the guidelines within which managers can pursue such opportunities. Simple rules, which grow out of experience, fall into five broad categories: how- to rules, boundary conditions, priority rules, timing rules, and exit rules. Companies with simple-rules strategies must follow the rules religiously and avoid the temptation to change them too frequently. A consistent strategy helps managers sort through opportunities and gain short-term advantage by exploiting the attractive ones. In stable markets, managers rely on complicated strategies built on detailed predictions of the future. But when business is complicated, strategy should be simple.

  9. Simple WZW currents

    International Nuclear Information System (INIS)

    Fuchs, J.

    1990-08-01

    A complete classification of simple currents of WZW theory is obtained. The proof is based on an analysis of the quantum dimensions of the primary fields. Simple currents are precisely the primaries with unit quantum dimension; for WZW theories explicit formulae for the quantum dimensions can be derived so that an identification of the fields with unit quantum dimension is possible. (author). 19 refs.; 2 tabs

  10. Tendência da mortalidade por câncer nas capitais e interior do Brasil entre 1980 e 2006 Tendencia de la mortalidad por cáncer en las capitales e interior de Brasil entre 1980 y 2006 Cancer mortality trends in Brazilian state capitals and other municipalities between 1980 and 2006

    Directory of Open Access Journals (Sweden)

    Gulnar Azevedo e Silva

    2011-12-01

    Full Text Available OBJETIVO: Analisar a tendência corrigida da mortalidade geral por câncer e principais tipos nas capitais e demais municípios do Brasil entre 1980 e 2006. MÉTODOS: Os dados sobre óbitos (n = 2.585.012 decorrentes de câncer entre 1980 e 2006 foram obtidos no Sistema de Informações sobre Mortalidade, e os demográficos, no Instituto Brasileiro de Geografia e Estatística. As taxas de mortalidade geral por câncer e principais tipos foram corrigidas redistribuindo proporcionalmente 50% das mortes mal definidas e padronizando-as por idade segundo população padrão mundial. As curvas de tendência para o Brasil e grandes regiões foram calculadas para capitais e demais municípios segundo sexo e avaliadas por meio de regressão linear simples. RESULTADOS: Entre os homens, as taxas de mortalidade para os cânceres de pulmão, próstata e colo-retal foram ascendentes; declinantes para o de estômago e estáveis para o de esôfago. Entre as mulheres, houve aumento da mortalidade por câncer de mama, pulmão e colo-retal; e diminuição das taxas para os cânceres de colo do útero e de estômago. A evolução da mortalidade variou entre as regiões do País, com padrões distintos entre as capitais e demais municípios. CONCLUSÕES: A correção das taxas de mortalidade com redistribuição dos óbitos mal definidos aumentou a magnitude da mortalidade geral por câncer no Brasil em cerca de 10% em 1980 e 5% em 2006. Nos municípios do interior não se observou tendência à queda ou estabilidade como nas capitais. Menor alcance das ações de prevenção e a dificuldade de acesso a serviços de diagnóstico e tratamento para câncer para a população residente fora dos grandes centros urbanos podem explicar, em parte, essas diferenças.OBJETIVO: Analizar la tendencia corregida de la mortalidad general por cáncer y principales tipos en las capitales y demás municipios de Brasil entre 1980 a 2006. MÉTODOS: Los datos sobre óbitos (n= 2

  11. Rapid radiological characterization method based on the use of dose coefficients

    International Nuclear Information System (INIS)

    Dulama, C.; Toma, Al.; Dobrin, R.; Valeca, M.

    2010-01-01

    Intervention actions in case of radiological emergencies and exploratory radiological surveys require rapid methods for the evaluation of the range and extent of contamination. When simple and homogeneous radionuclide composition characterize the radioactive contamination, surrogate measurements can be used to reduce the costs implied by laboratory analyses and to speed-up the process of decision support. A dose-rate measurement-based methodology can be used in conjunction with adequate dose coefficients to assess radionuclide inventories and to calculate dose projections for various intervention scenarios. The paper presents the results obtained for dose coefficients in some particular exposure geometries and the methodology used for deriving dose rate guidelines from activity concentration upper levels specified as contamination limits. All calculations were performed by using the commercial software MicroShield from Grove Software Inc. A test case was selected as to meet the conditions from EPA Federal Guidance Report no. 12 (FGR12) concerning the evaluation of dose coefficients for external exposure from contaminated soil and the obtained results were compared to values given in the referred document. The geometries considered as test cases are: contaminated ground surface; - infinite extended homogeneous surface contamination and soil contaminated to a depth of 15 cm. As shown by the results, the values agree within 50% relative difference for most of the cases. The greatest discrepancies were observed for depth contamination simulation and in the case of radionuclides with complicated gamma emission and this is due to the different approach from MicroShield and FGR12. A case study is presented for validation of the methodology, where both dose rate measurements and laboratory analyses were performed on an extended quasi-homogeneous NORM contamination. The dose rate estimations obtained by applying the dose coefficients to the radionuclide concentrations

  12. Development of dose monitoring system applicable to various radiations with wide energy ranges

    International Nuclear Information System (INIS)

    Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira

    2006-01-01

    A new radiation dose monitor, designated as DARWIN (Dose monitoring system Applicable to various Radiations with WIde energy raNges), has been developed for real-time monitoring of doses in workspaces and surrounding environments of high energy accelerator facilities. DARWIN is composed of a phoswitch-type scintillation detector, which consists of liquid organic scintillator BC501A coupled with ZnS(Ag) scintillation sheets doped with 6 Li, and a data acquisition system based on a Digital-Storage-Oscilloscope. DARWIN has the following features: (1) capable of monitoring doses from neutrons, photons and muons with energies from thermal energy to 1 GeV, 150 keV to 100 MeV, and 1 MeV to 100 GeV, respectively, (2) highly sensitive with precision, and (3) easy to operate with a simple graphical user-interface. The performance of DARWIN was examined experimentally in several radiation fields. The results of the experiments indicated the accuracy and rapid response of DARWIN for measuring dose rates from neutrons, photons and muons with wide energies. With these properties, we conclude that DARWIN will be able to play a very important role for improving radiation safety in high energy accelerator facilities. (author)

  13. Darwin: Dose monitoring system applicable to various radiations with wide energy ranges

    International Nuclear Information System (INIS)

    Sato, T.; Satoh, D.; Endo, A.; Yamaguchi, Y.

    2007-01-01

    A new radiation dose monitor, designated as DARWIN (Dose monitoring system Applicable to various Radiations with Wide energy ranges), has been developed for real-time monitoring of doses in workspaces and surrounding environments of high-energy accelerator facilities. DARWIN is composed of a Phoswitch-type scintillation detector, which consists of liquid organic scintillator BC501A coupled with ZnS(Ag) scintillation sheets doped with 6 Li, and a data acquisition system based on a Digital-Storage-Oscilloscope. DARWIN has the following features: (1) capable of monitoring doses from neutrons, photons and muons with energies from thermal energy to 1 GeV, 150 keV to 100 MeV and 1 MeV to 100 GeV, respectively, (2) highly sensitive with precision and (3) easy to operate with a simple graphical user-interface. The performance of DARWIN was examined experimentally in several radiation fields. The results of the experiments indicated the accuracy and wide response range of DARWIN for measuring dose rates from neutrons, photons and muons with wide energies. It was also found from the experiments that DARWIN enables us to monitor small fluctuations of neutron dose rates near the background level because of its high sensitivity. With these properties, DARWIN will be able to play a very important role for improving radiation safety in high-energy accelerator facilities. (authors)

  14. The 3D Radiation Dose Analysis For Satellite

    Science.gov (United States)

    Cai, Zhenbo; Lin, Guocheng; Chen, Guozhen; Liu, Xia

    2002-01-01

    the earth. These particles come from the Van Allen Belt, Solar Cosmic Ray and Galaxy Cosmic Ray. They have different energy and flux, varying with time and space, and correlating with solar activity tightly. These particles interact with electrical components and materials used on satellites, producing various space radiation effects, which will damage satellite to some extent, or even affect its safety. orbit. Space energy particles inject into components and materials used on satellites, and generate radiation dose by depositing partial or entire energy in them through ionization, which causes their characteristic degradation or even failure. As a consequence, the analysis and protection for radiation dose has been paid more attention during satellite design and manufacture. Designers of satellites need to analyze accurately the space radiation dose while satellites are on orbit, and use the results as the basis for radiation protection designs and ground experiments for satellites. can be calculated, using the model of the trapped proton and the trapped electron in the Van Allen Belt (AE8 and AP8). This is the 1D radiation dose analysis for satellites. Obviously, the mass shielding from the outside space to the computed point in all directions is regarded as a simple sphere shell. The actual structure of satellites, however, is very complex. When energy particles are injecting into a given equipment inside satellite from outside space, they will travel across satellite structure, other equipment, the shell of the given equipment, and so on, which depends greatly on actual layout of satellite. This complex radiation shielding has two characteristics. One is that the shielding masses for the computed point are different in different injecting directions. The other is that for different computed points, the shielding conditions vary in all space directions. Therefore, it is very difficult to tell the differences described above using the 1D radiation analysis, and

  15. A simple method to identify radiation and annealing biases that lead to worst-case CMOS static RAM postirradiation response

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Dressendorfer, P.V.

    1987-01-01

    The authors illustrate a simple method to identify bias conditions that lead to worst-case postirradiation speed and timing response for SRAMs. Switching cell states between radiation and anneal should lead to maximum speed and timing degradation for many hardened designs and technologies. The greatest SRAM cell imbalance is also established by these radiation and annealing conditions for the hardened and commercial parts that we have examined. These results should provide insight into the behavior of SRAMs during and after irradiation. The results should also be useful to establishing guidelines for integrated-circuit functionality testing, and SEU and dose-rate upset testing, after total-dose irradiation

  16. Concordancia entre el diagnóstico clínico y el patológico por necropsias

    Directory of Open Access Journals (Sweden)

    VALDEZ-MARTÍNEZ EDITH

    1998-01-01

    Full Text Available Objetivo. Determinar la concordancia entre diagnósticos clínicos y patológicos con base en los resultados de necropsias. Material y métodos. Se revisaron 67 protocolos de necropsia y expedientes clínicos de niños y adultos del servicio de patología del Centro de Especialidades Médicas del Estado de Veracruz Doctor Rafael Lucio, durante 1995 y 1996. Se obtuvieron las frecuencias simples de las variables de estudio, y la concordancia se calculó con el estadístico kappa simple. Resultados. En general la cifra de necropsias fue de 10.5%. Correspondió a la población infantil la mayor frecuencia (17.5%. El 59% de diagnósticos clínicos en niños y el 57% en adultos presentaron algún tipo de error La concordancia del diagnóstico principal ante y postmortem fue de 26% (infantes y 41% (adultos. Conclusiones. La alta cifra de errores diagnósticos y la consecuente baja concordancia clínicopatológica apoyan el hecho de que, a pesar del avance tecnológico en los procedimientos diagnósticos, es necesario realizar necropsias con el fin de documentar de manera más definitiva el control de calidad del ejercicio de la medicina.

  17. Complex, non-monotonic dose-response curves with multiple maxima: Do we (ever) sample densely enough?

    Science.gov (United States)

    Cvrčková, Fatima; Luštinec, Jiří; Žárský, Viktor

    2015-01-01

    We usually expect the dose-response curves of biological responses to quantifiable stimuli to be simple, either monotonic or exhibiting a single maximum or minimum. Deviations are often viewed as experimental noise. However, detailed measurements in plant primary tissue cultures (stem pith explants of kale and tobacco) exposed to varying doses of sucrose, cytokinins (BA or kinetin) or auxins (IAA or NAA) revealed that growth and several biochemical parameters exhibit multiple reproducible, statistically significant maxima over a wide range of exogenous substance concentrations. This results in complex, non-monotonic dose-response curves, reminiscent of previous reports of analogous observations in both metazoan and plant systems responding to diverse pharmacological treatments. These findings suggest the existence of a hitherto neglected class of biological phenomena resulting in dose-response curves exhibiting periodic patterns of maxima and minima, whose causes remain so far uncharacterized, partly due to insufficient sampling frequency used in many studies.

  18. Development of fluorescent, oscillometric and photometric methods to determine absorbed dose in irradiated fruits and nuts

    International Nuclear Information System (INIS)

    Kovacs, A.; Foeldiak, G.; Hargittai, P.; Miller, S.D.

    2001-01-01

    To ensure suitable quality control at food irradiation technologies and for quarantine authorities, simple routine dosimetry methods are needed for absorbed dose control. Taking into account the requirements at quarantine locations these methods would require nondestructive analysis for repeated measurements. Different dosimetry systems with different analytical evaluation methods have been tested and/or developed for absorbed dose measurements in the dose range of 0.1-10 kGy. In order to use the well accepted ethanolmonochlorobenzene dosimeter solution and the recently developed aqueous alanine solution in small volume sealed vials, a new portable, digital, and programmable oscillometric reader was developed. To make use of the availability of the very sensitive fluorimetric evaluation method, liquid and solid inorganic and organic dosimetry systems were developed for dose control using a new routine, portable, and computer controlled fluorimeter. Absorption or transmission photometric methods were also applied for dose measurements of solid or liquid phase dosimeter systems containing radiochromic dye agents, which change colour upon irradiation. (author)

  19. Structure of simple liquids; Structure des liquides simples

    Energy Technology Data Exchange (ETDEWEB)

    Blain, J F [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    The results obtained by application to argon and sodium of the two important methods of studying the structure of liquids: scattering of X-rays and neutrons, are presented on one hand. On the other hand the principal models employed for reconstituting the structure of simple liquids are exposed: mathematical models, lattice models and their derived models, experimental models. (author) [French] On presente d'une part les resultats obtenus par application a l'argon et au sodium des deux principales methodes d'etude de la structure des liquides: la diffusion des rayons X et la diffusion des neutrons; d'autre part, les principaux modeles employes pour reconstituer la structure des liquides simples sont exposes: modeles mathematiques, modeles des reseaux et modeles derives, modeles experimentaux. (auteur)

  20. Patterns of alcohol use among Brazilian adolescents Padrões de uso de álcool entre adolescentes brasileiros

    Directory of Open Access Journals (Sweden)

    Ilana Pinsky

    2010-09-01

    ício da experimentação de bebidas alcoólicas foi de 14 anos. Adolescentes mais velhos, habitando a região Sul, que não estudam, que trabalham, de cor negra e que têm rendimento próprio apresentaram maior frequência de consumo. A quantidade usual consumida varia de acordo com sexo, classe social, renda familiar e o fato de estudar ou não. Os jovens do sexo masculino se destacam por apresentarem um percentual bem maior do beber em binge quando comparados com as jovens e mais da metade dos adolescentes do sexo masculino que bebem o fizeram em binge em pelo menos em uma ocasião. Aproximadamente metade das doses consumidas por adolescentes é de cerveja ou chope. Com relação aos gêneros, não foi detectada diferença significativa entre tipos de bebida. DISCUSSÃO: O consumo de altas doses é frequente entre os adolescentes. Os padrões de consumo dos adolescentes apresentam variações em relação a região, estrato social, rendimentos próprios e idade. Os achados têm importância para o estabelecimento de políticas nacionais.

  1. Las relaciones de comercio e inversión entre Colombia y Venezuela

    OpenAIRE

    Eglé Iturbe de Blanco

    1997-01-01

    Venezuela y Colombia cuentan con una larga trayectoria histórica en sus relaciones económicas. Comercian entre ellas y sus nacionales a lo largo de la frontera desde su nacimiento como naciones e interactúan entre ambos países como si fuera uno solo. Al norte, en la península de la Guajira, viven poblaciones indígenas comunes cuyo sustento es el comercio entre ambos lados de la frontera; y al sur, en los estados andinos venezolanos limítrofes con los llanos colombianos, tradicionalmente se ha...

  2. Inherent calibration of microdosemeters for dose distributions in lineal energy

    Energy Technology Data Exchange (ETDEWEB)

    Crossman, J.S.P.; Watt, D.E. [Saint Andrews Univ. (United Kingdom). Dept. of Physics and Astronomy

    1994-12-31

    A method, utilising the inherent electron event spectra, is described for the absolute calibration of microdosemeters in the presence of a photon field. The method, which avoids the problems and uncertainties present in conventional calibration techniques, involves simple extrapolation of the dose distribution in lineal energy associated with `exact stopper` electrons. Validation of the method is made using the published experimental distributions of Rossi, of Kliauga, and of Dvorak and by direct theoretical calculation of the components of the microdose distributions for gamma rays. Further experimental data from a cylindrical TEPC in a photon field generated by an external source of {sup 137}Cs are obtained for comparison. A `universal` calibration curve for the dose-weighted lineal energy as a function of the simulated mean diameter of the microdosemeter, is presented for use in practical applications. (author).

  3. Inherent calibration of microdosemeters for dose distributions in lineal energy

    International Nuclear Information System (INIS)

    Crossman, J.S.P.; Watt, D.E.

    1994-01-01

    A method, utilising the inherent electron event spectra, is described for the absolute calibration of microdosemeters in the presence of a photon field. The method, which avoids the problems and uncertainties present in conventional calibration techniques, involves simple extrapolation of the dose distribution in lineal energy associated with 'exact stopper' electrons. Validation of the method is made using the published experimental distributions of Rossi, of Kliauga, and of Dvorak and by direct theoretical calculation of the components of the microdose distributions for gamma rays. Further experimental data from a cylindrical TEPC in a photon field generated by an external source of 137 Cs are obtained for comparison. A 'universal' calibration curve for the dose-weighted lineal energy as a function of the simulated mean diameter of the microdosemeter, is presented for use in practical applications. (author)

  4. Calculation of organ doses in x-ray examinations of premature babies

    International Nuclear Information System (INIS)

    Smans, Kristien; Tapiovaara, Markku; Cannie, Mieke; Struelens, Lara; Vanhavere, Filip; Smet, Marleen; Bosmans, Hilde

    2008-01-01

    Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a significant radiation detriment. Knowledge of the radiation dose is therefore necessary to justify the exposures. To calculate doses in the entire body and in specific organs, computational models of the human anatomy are needed. Using medical imaging techniques, voxel phantoms have been developed to achieve a representation as close as possible to the anatomical properties. In this study two voxel phantoms, representing prematurely born babies, were created from computed tomography- and magnetic resonance images: Phantom 1 (1910 g) and Phantom 2 (590 g). The two voxel phantoms were used in Monte Carlo calculations (MCNPX) to assess organ doses. The results were compared with the commercially available software package PCXMC in which the available mathematical phantoms can be downsized toward the prematurely born baby. The simple phantom-scaling method used in PCXMC seems to be sufficient to calculate doses for organs within the radiation field. However, one should be careful in specifying the irradiation geometry. Doses in organs that are wholly or partially outside the primary radiation field depend critically on the irradiation conditions and the phantom model

  5. Relaciones entre los salarios y la productividad en Colombia

    OpenAIRE

    Méndez Sayago, Jhon Alexander

    2017-01-01

    Esta tesis de doctorado está compuesta de cuatro artículos que tienen como propósito estudiar las relaciones entre los salarios y la productividad laboral en Colombia. Los dos primeros artículos denominados “Salario real y eficiencia del trabajo en el sector manufacturero en Colombia” y “Análisis de causalidad y sensibilidad entre los salarios reales y la productividad laboral en el sector manufacturero a partir de cifras de los departamentos en Colombia” aportan evidencia empírica sobre la d...

  6. Correlação entre a incapacidade funcional, idade e enzimas séricas nas doenças neuromusculares

    Directory of Open Access Journals (Sweden)

    Lineu Cesar Werneck

    1995-03-01

    Full Text Available Foram estudados 806 casos de diversas doenças neuromusculares, a fim de verificar se existe correlação entre o grau de incapacidade funcional aferida pela escala de Vignos e Archibald (V&A e enzimas séricas (creatinoquinase, desidrogenase lática, aldolase, transaminase glutâmica oxalacética e pirúvica. Foram utilizados testes para a análise do coeficiente de correlação simples (Pearson e múltiplo. Foi encontrada correlação positiva (piora progressiva da incapacidade da V&A com a idade em algumas doenças, como a distrofia muscular de Duchenne, distrofia fascio-escapulo-umeral, distrofia miotônica, miopatias com defeitos enzimáticos da cadeia respiratória e esclerose lateral amiotrófica. Por outro lado, foi detectada correlação negativa (melhora progressiva dos sintomas na miopatia do multicore, miopatia benigna da infância com predomínio de fibras do tipo 1, deficiência de carnitina e dermatomiosite. A V&A mostrou maiores correlações (p< 0,05 entre as diversas enzimas sérícas quando estudadas isoladamente na distrofia muscular de Duchenne, distrofia óculo-crânio-somática, polimiositcs e periarterite nodosa. Quando as enzimas foram analisadas em conjunto, através de teste de correlação múltipla, verificou-se pequena correlação entre elas e a V&A. Esta reduzida interrelação sugere que a utilização de diversas enzimas na análise longitudinal das doenças neuromusculares é limitada, não tendo aplicação pratica, embora sejam muito importantes no diagnóstico.

  7. Dose planning and dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Knoeoes, T.

    1991-01-01

    A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, making an objective evaluation of dose calculations with experiments feasible. The methods for electron density determination, dose calculation and prediction of accelerator output discussed in this study will all contribute to an increased accuracy in the mean absorbed dose to the target volume. However, a substantial gain in the accuracy for the spatial absorbed dose distribution will also follow, especially using CT for mapping of electron density together with the dose calculation algorithm. (au)

  8. Normal tissue dose-effect models in biological dose optimisation

    International Nuclear Information System (INIS)

    Alber, M.

    2008-01-01

    Sophisticated radiotherapy techniques like intensity modulated radiotherapy with photons and protons rely on numerical dose optimisation. The evaluation of normal tissue dose distributions that deviate significantly from the common clinical routine and also the mathematical expression of desirable properties of a dose distribution is difficult. In essence, a dose evaluation model for normal tissues has to express the tissue specific volume effect. A formalism of local dose effect measures is presented, which can be applied to serial and parallel responding tissues as well as target volumes and physical dose penalties. These models allow a transparent description of the volume effect and an efficient control over the optimum dose distribution. They can be linked to normal tissue complication probability models and the equivalent uniform dose concept. In clinical applications, they provide a means to standardize normal tissue doses in the face of inevitable anatomical differences between patients and a vastly increased freedom to shape the dose, without being overly limiting like sets of dose-volume constraints. (orig.)

  9. Simple Rules, Not So Simple: The Use of International Ovarian Tumor Analysis (IOTA) Terminology and Simple Rules in Inexperienced Hands in a Prospective Multicenter Cohort Study.

    Science.gov (United States)

    Meys, Evelyne; Rutten, Iris; Kruitwagen, Roy; Slangen, Brigitte; Lambrechts, Sandrina; Mertens, Helen; Nolting, Ernst; Boskamp, Dieuwke; Van Gorp, Toon

    2017-12-01

     To analyze how well untrained examiners - without experience in the use of International Ovarian Tumor Analysis (IOTA) terminology or simple ultrasound-based rules (simple rules) - are able to apply IOTA terminology and simple rules and to assess the level of agreement between non-experts and an expert.  This prospective multicenter cohort study enrolled women with ovarian masses. Ultrasound was performed by non-expert examiners and an expert. Ultrasound features were recorded using IOTA nomenclature, and used for classifying the mass by simple rules. Interobserver agreement was evaluated with Fleiss' kappa and percentage agreement between observers.  50 consecutive women were included. We observed 46 discrepancies in the description of ovarian masses when non-experts utilized IOTA terminology. Tumor type was misclassified often (n = 22), resulting in poor interobserver agreement between the non-experts and the expert (kappa = 0.39, 95 %-CI 0.244 - 0.529, percentage of agreement = 52.0 %). Misinterpretation of simple rules by non-experts was observed 57 times, resulting in an erroneous diagnosis in 15 patients (30 %). The agreement for classifying the mass as benign, malignant or inconclusive by simple rules was only moderate between the non-experts and the expert (kappa = 0.50, 95 %-CI 0.300 - 0.704, percentage of agreement = 70.0 %). The level of agreement for all 10 simple rules features varied greatly (kappa index range: -0.08 - 0.74, percentage of agreement 66 - 94 %).  Although simple rules are useful to distinguish benign from malignant adnexal masses, they are not that simple for untrained examiners. Training with both IOTA terminology and simple rules is necessary before simple rules can be introduced into guidelines and daily clinical practice. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Induction of lacI- mutations in Escherichia coli cells after single and split-dose irradiation

    International Nuclear Information System (INIS)

    Kozubek, S.; Ryznar, L.

    1992-01-01

    In the lacI system of Escherichia coli, X-ray mutagenesis follows a linear-quadratic curve with suppression; the survival curve is exponential. Dose fractionation leads to nearly complete repair of premutational lesions during an incubation interval of 3.5 h. Repair starts with a delay of 1.5-2 h, suggesting the involvement of an inducible repair/mutation fixation system. The dose-dependence of mutagenesis is described by a simple model assuming two hits being required. A probable explanation might be that the premutagenic lesions consist of two closely spaced lesions on the opposite strands of the DNA molecule. (author)

  11. Spacings between plants with chicken manure in Roselle crop=Espaçamentos entre plantas e cama-de-frango na produção de Rosela.

    Directory of Open Access Journals (Sweden)

    Thiago Oliveira Carnevali

    2011-10-01

    Full Text Available The purpose of this work was to analyze the effects of plant spacing within rows by means of applying or not applying chicken manure to the soil cover in the growth and yields of roselle biomass. The treatments consisted of five spacings between plants (0.30, 0.35, 0.40, 0.45 and 0.50 m and the application or non application of chicken manure to the soil cover in a dose of 10 ton. ha-1, arranged in randomized blocks of 5 x 2 with four replicates. The maximum plant height (282.92 cm was achieved at 200 days after the transplant (DAT, with 0.35 m between plants and without the application of chicken manure. The leaf area was significantly influenced by the interaction of the spacings between plants and the application of chicken manure, presenting a linear growth of 32,009 cm2 plants-1. The biggest fresh and dry weight yields in leaves were 31,571 and 3,339 kg ha-1, respectively, with a 0.30 m spacing between the plants. The biggest yields of both fresh and dry weights of the stems and fruits of roselle plants were obtained in the soil with chicken manure.O objetivo deste trabalho foi avaliar o efeito de espaçamentos entre plantas dentro das fileiras e do uso ou não de cama-de-frango na cobertura do solo sobre o crescimento e a produção de biomassa de plantas de rosela. Os tratamentos consistiram de cinco espaçamentos entre plantas (0,30; 0,35; 0,40; 0,45 e 0,50 m e do uso ou não de cama-de-frango em cobertura do solo, na dose de 10 t ha-1, arranjados como fatorial 5 x 2, no delineamento de blocos casualizados, com quatro repetições. A altura máxima da planta (282,92 cm foi alcançada aos 200 dias após o transplante (DAT sob 0,35 m entre plantas e sem o uso de cama-de-frango. A área foliar foi influenciada significativamente pela interação espaçamentos e cama-de-frango e cresceu linearmente com os espaçamentos entre plantas, sendo de 32.009 cm2 planta-1 com cama. As maiores produções de massas frescas e secas de folhas foram de 31

  12. The characteristics on dose distribution of a large field

    International Nuclear Information System (INIS)

    Lee, Sang Rok; Jeong, Deok Yang; Lee, Btiung Koo; Kwon, Young Ho

    2003-01-01

    In special cases of Total Body Irradiation(TBI), Half Body Irradiation(HBI), Non-Hodgkin's lymphoma, E-Wing's sarcoma, lymphosarcoma and neuroblastoma a large field can be used clinically. The dose distribution of a large field can use the measurement result which gets from dose distribution of a small field (standard SSD 100 cm, size of field under 40 x 40 cm 2 ) in the substitution which always measures in practice and it will be able to calibrate. With only the method of simple calculation, it is difficult to know the dose and its uniformity of actual body region by various factor of scatter radiation. In this study, using Multidata Water Phantom from standard SSD 100 cm according to the size change of field, it measures the basic parameter (PDD,TMR,Output,Sc,Sp) From SSD 180 cm (phantom is to the bottom vertically) according to increasing of a field, it measures a basic parameter. From SSD 350 cm (phantom is to the surface of a wall, using small water phantom. which includes mylar capable of horizontal beam's measurement) it measured with the same method and compared with each other. In comparison with the standard dose data, parameter which measures between SSD 180 cm and 350 cm, it turned out there was little difference. The error range is not up to extent of the experimental error. In order to get the accurate data, it dose measures from anthropomorphous phantom or for this objective the dose measurement which is the possibility of getting the absolute value which uses the unlimited phantom that is devised especially is demanded. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field.

  13. SU-E-T-762: Toward Volume-Based Independent Dose Verification as Secondary Check

    International Nuclear Information System (INIS)

    Tachibana, H; Tachibana, R

    2015-01-01

    Purpose: Lung SBRT plan has been shifted to volume prescription technique. However, point dose agreement is still verified using independent dose verification at the secondary check. The volume dose verification is more affected by inhomogeneous correction rather than point dose verification currently used as the check. A feasibility study for volume dose verification was conducted in lung SBRT plan. Methods: Six SBRT plans were collected in our institute. Two dose distributions with / without inhomogeneous correction were generated using Adaptive Convolve (AC) in Pinnacle3. Simple MU Analysis (SMU, Triangle Product, Ishikawa, JP) was used as the independent dose verification software program, in which a modified Clarkson-based algorithm was implemented and radiological path length was computed using CT images independently to the treatment planning system. The agreement in point dose and mean dose between the AC with / without the correction and the SMU were assessed. Results: In the point dose evaluation for the center of the GTV, the difference shows the systematic shift (4.5% ± 1.9 %) in comparison of the AC with the inhomogeneous correction, on the other hands, there was good agreement of 0.2 ± 0.9% between the SMU and the AC without the correction. In the volume evaluation, there were significant differences in mean dose for not only PTV (14.2 ± 5.1 %) but also GTV (8.0 ± 5.1 %) compared to the AC with the correction. Without the correction, the SMU showed good agreement for GTV (1.5 ± 0.9%) as well as PTV (0.9% ± 1.0%). Conclusion: The volume evaluation for secondary check may be possible in homogenous region. However, the volume including the inhomogeneous media would make larger discrepancy. Dose calculation algorithm for independent verification needs to be modified to take into account the inhomogeneous correction

  14. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

    International Nuclear Information System (INIS)

    Goma, Carles; Ruiz, Agustin; Jornet, Nuria; Latorre, Artur; Pallerol, Rosa M.; Carrasco, Pablo; Eudaldo, Teresa; Ribas, Montserrat

    2011-01-01

    Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI 100 as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI 100 is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, σ. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI 100 calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the

  15. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goma, Carles; Ruiz, Agustin; Jornet, Nuria; Latorre, Artur; Pallerol, Rosa M.; Carrasco, Pablo; Eudaldo, Teresa; Ribas, Montserrat [Servei de Radiofisica i Radioproteccio, Hospital de la Santa Creu i Sant Pau, Sant Antoni Maria Claret 167, 08025 Barcelona (Spain)

    2011-03-15

    Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good

  16. Regression models in the determination of the absorbed dose with extrapolation chamber for ophthalmological applicators

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Morales P, R.

    1992-06-01

    The absorbed dose for equivalent soft tissue is determined,it is imparted by ophthalmologic applicators, ( 90 Sr/ 90 Y, 1850 MBq) using an extrapolation chamber of variable electrodes; when estimating the slope of the extrapolation curve using a simple lineal regression model is observed that the dose values are underestimated from 17.7 percent up to a 20.4 percent in relation to the estimate of this dose by means of a regression model polynomial two grade, at the same time are observed an improvement in the standard error for the quadratic model until in 50%. Finally the global uncertainty of the dose is presented, taking into account the reproducibility of the experimental arrangement. As conclusion it can infers that in experimental arrangements where the source is to contact with the extrapolation chamber, it was recommended to substitute the lineal regression model by the quadratic regression model, in the determination of the slope of the extrapolation curve, for more exact and accurate measurements of the absorbed dose. (Author)

  17. Simple-MSSM: a simple and efficient method for simultaneous multi-site saturation mutagenesis.

    Science.gov (United States)

    Cheng, Feng; Xu, Jian-Miao; Xiang, Chao; Liu, Zhi-Qiang; Zhao, Li-Qing; Zheng, Yu-Guo

    2017-04-01

    To develop a practically simple and robust multi-site saturation mutagenesis (MSSM) method that enables simultaneously recombination of amino acid positions for focused mutant library generation. A general restriction enzyme-free and ligase-free MSSM method (Simple-MSSM) based on prolonged overlap extension PCR (POE-PCR) and Simple Cloning techniques. As a proof of principle of Simple-MSSM, the gene of eGFP (enhanced green fluorescent protein) was used as a template gene for simultaneous mutagenesis of five codons. Forty-eight randomly selected clones were sequenced. Sequencing revealed that all the 48 clones showed at least one mutant codon (mutation efficiency = 100%), and 46 out of the 48 clones had mutations at all the five codons. The obtained diversities at these five codons are 27, 24, 26, 26 and 22, respectively, which correspond to 84, 75, 81, 81, 69% of the theoretical diversity offered by NNK-degeneration (32 codons; NNK, K = T or G). The enzyme-free Simple-MSSM method can simultaneously and efficiently saturate five codons within one day, and therefore avoid missing interactions between residues in interacting amino acid networks.

  18. Measurement of the dose distribution at the gammatron in homogeneous water phantoms with films and ionization chambers

    International Nuclear Information System (INIS)

    Mark, B.

    1978-01-01

    The check of the analytic function for the depth-dose-curve by means of computer calculations of films shows, that only with the knowledge of the phantom depth factor the film is able to deliver quick and relatively simple gives information on the degree of the decrease of the dose with increasing phantom depth. Outside of the effective beam the deviation between the values, determines photometrically and ionometrically is up to 100 per cent. The analytic function could be veryfied well ionometrically. The transversal distributions were also checked, that are the basis for the dose calculation in a pendulum irradiation. A good agreement was found between the ionometrical and film-dosimetrical values. (orig.) [de

  19. Measurement of radiocesium concentration in trees using cumulative gamma radiation dose rate detection systems - A simple presumption for radiocesium concentration in living woods using glass-badge based gamma radiation dose rate detection system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, T.; Hashida, S.N. [Plant Molecular Biology, Laboratory of Environmental Science, Central Research Institute of Electric Power Industry (CRIEPI), 1646 Abiko, Chiba 270-1194 (Japan); Kawachi, N.; Suzui, N.; Yin, Y.G.; Fujimaki, S. [Radiotracer Imaging Gr., Quantum Beam Science Center, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagao, Y.; Yamaguchi, M. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-07-01

    Radiocesium from the severe accident at the Fukushima Dai-ichi Nuclear Power Plant on 11 March 2011 contaminates large areas. After this, a doubt for forest products, especially of mushroom, is indelible at the areas. Pruned woody parts and litters are containing a considerable amount of radiocesium, and generates a problem at incineration and composting. These mean that more attentive survey for each subject is expected; however, the present survey system is highly laborious/expensive and/or non-effective for this purpose. On the other hand, we can see a glass-badge based gamma radiation dose rate detection system. This system always utilized to detect a personal cumulative radiation dose, and thus, it is not suitable to separate a radiation from a specific object. However, if we can separate a radiation from a specific object and relate it with the own radiocesium concentration, it would enable us to presume the specific concentration with just an easy monitoring but without a destruction of the target nature and a complicated process including sampling, pre-treatment, and detection. Here, we present the concept of the measurement and results of the trials. First, we set glass-badges (type FS, Chiyoda Technol Corp., Japan) on a part of bough (approximately 10 cm in diameter) of Japanese flowering cherry trees (Prunus x yedoensis cv. Somei-Yoshino) with four different settings: A, a direct setting without any shield; B, a setting with an aluminum shield between bough and the glass-badge; C, a setting with a lead shield between bough and the glass-badge; D, a setting with a lead shield covering the glass-badge to shut the radiation from the surrounding but from bough. The deduction between the amount of each setting should separate a specific radiation of the bough from unlimited radiation from the surrounding. Even if the hourly dose rate is not enough to count the difference, a moderate cumulative dose would clear the difference. In fact, results demonstrated a

  20. Correlación entre homofobia y racismo en estudiantes de medicina

    Directory of Open Access Journals (Sweden)

    Adalberto Campo-Arias

    2014-01-01

    Full Text Available El objetivo de este estudio fue determinar la correlación entre homofobia y racismo en estudiantes de medicina de Bucaramanga (Colombia. Se realizó un estudio transversal que incluyó a estudiantes mayores de 18 años. La actitud hacia homosexuales (homofobia o prejuicio sexual se midió con la Escala de Homofobia (EHF y la actitud hacia afrocolombianos (el racismo o la discriminación racial, con una versión en español de la Escala de Racismo Moderno (MRS. La asociación entre homofobia y racismo se calculó con los coeficientes de Pearson (r y Spearman (rs. Un grupo de 334 estudiantes aceptó participar. La media para la edad fue 20,1 años (DE=1,9, 59,0 % eran mujeres. El alfa de Cronbach fue 0,78 para la EHF y 0,62 para la MRS. Las puntuaciones en la EHF fueron entre 7 y 34 (media=17,8; SD=5,4 y en la MRS, entre 0 y 34 (media=13,8; SD=5,2. El coeficiente r fue 0,35 (p<0,001 y rs, 0,34 (p<0,001. Se concluye que existe correlación positiva entre estas formas de prejuicio (la homofobia y el racismo en estudiantes de medicina de Bucaramanga. Se necesita una intervención para reducir los prejuicios en los estudiantes de medicina.

  1. The Dose Rate Dependence of the Yield of Trapped Electrons in Crystalline Ice

    DEFF Research Database (Denmark)

    Nilsson, Johan Daniel Göran; Pagsberg, Palle Bjørn

    1980-01-01

    in competition with other reactions and we propose a simple model where we assume that the mobile electrons can undergo bimolecular bulk reactions with protons and OH radicals. Rate constants of 3.0 × 1015 M−1 S−1 and 1.4 × 1014 M−1 S−1 for the two reactions were required in the model in order to account......The yield of localized excess electrons in crystalline H2O ice has been studied as a function of the dose rate at various temperatures in the range −10 to −40°C. The G value was found to decrease significantly with increasing dose rate. Thus it appears that the localization of electrons takes place...

  2. A convolution-superposition dose calculation engine for GPUs

    Energy Technology Data Exchange (ETDEWEB)

    Hissoiny, Sami; Ozell, Benoit; Despres, Philippe [Departement de genie informatique et genie logiciel, Ecole polytechnique de Montreal, 2500 Chemin de Polytechnique, Montreal, Quebec H3T 1J4 (Canada); Departement de radio-oncologie, CRCHUM-Centre hospitalier de l' Universite de Montreal, 1560 rue Sherbrooke Est, Montreal, Quebec H2L 4M1 (Canada)

    2010-03-15

    Purpose: Graphic processing units (GPUs) are increasingly used for scientific applications, where their parallel architecture and unprecedented computing power density can be exploited to accelerate calculations. In this paper, a new GPU implementation of a convolution/superposition (CS) algorithm is presented. Methods: This new GPU implementation has been designed from the ground-up to use the graphics card's strengths and to avoid its weaknesses. The CS GPU algorithm takes into account beam hardening, off-axis softening, kernel tilting, and relies heavily on raytracing through patient imaging data. Implementation details are reported as well as a multi-GPU solution. Results: An overall single-GPU acceleration factor of 908x was achieved when compared to a nonoptimized version of the CS algorithm implemented in PlanUNC in single threaded central processing unit (CPU) mode, resulting in approximatively 2.8 s per beam for a 3D dose computation on a 0.4 cm grid. A comparison to an established commercial system leads to an acceleration factor of approximately 29x or 0.58 versus 16.6 s per beam in single threaded mode. An acceleration factor of 46x has been obtained for the total energy released per mass (TERMA) calculation and a 943x acceleration factor for the CS calculation compared to PlanUNC. Dose distributions also have been obtained for a simple water-lung phantom to verify that the implementation gives accurate results. Conclusions: These results suggest that GPUs are an attractive solution for radiation therapy applications and that careful design, taking the GPU architecture into account, is critical in obtaining significant acceleration factors. These results potentially can have a significant impact on complex dose delivery techniques requiring intensive dose calculations such as intensity-modulated radiation therapy (IMRT) and arc therapy. They also are relevant for adaptive radiation therapy where dose results must be obtained rapidly.

  3. Determination of carcinogenic threshold limit values using the tumorigenic dose rate 50% (TD50)

    International Nuclear Information System (INIS)

    Bonvalot, Y.; Oudiz, A.; Hubert, P.; Abenhaim, L.

    1989-01-01

    The objective of the present study is to propose a simple procedure for the determination of Occupational Limit Values (OLVs) based on the TD 50 concept (Tumorigenic Dose Rate 50%). The TD 50 concept was introduced by Peto R. and al. to help classify chemical substances according to their carcinogenic potency. The TD 50 is that dose rate (in mg/KXg body weight/day) which, if administered chronically for the standard lifespan of the species will halve the probability of remaining tumorless throughout that period. Using TD 50 values available for 776 substances, the procedure presented here allows one to determine OLVs corresponding to a fixed excess risk. It is based on a mathematical high-to-low doses extrapolation of the TD 50 . OLVs obtained with this procedure are compared with currently available TLVs and other occupational guidelines. (author)

  4. Internal Mammary Lymph Node Irradiation Contributes to Heart Dose in Breast Cancer

    International Nuclear Information System (INIS)

    Chargari, Cyrus; Castadot, Pierre; MacDermed, Dhara; Vandekerkhove, Christophe; Bourgois, Nicolas; Van Houtte, Paul; Magne, Nicolas

    2010-01-01

    We assessed the impact of internal mammary chain radiotherapy (IMC RT) to the radiation dose received by the heart in terms of heart dose-volume histogram (DVH). Thirty-six consecutive breast cancer patients presenting with indications for IMC RT were enrolled in a prospective study. The IMC was treated by a standard conformal RT technique (50 Gy). For each patient, a cardiac DVH was generated by taking into account the sole contribution of IMC RT. Cardiac HDV were compared according to breast cancer laterality and the type of previous surgical procedure, simple mastectomy or breast conservative therapy (BCT). The contribution of IMC RT to the heart dose was significantly greater for patients with left-sided versus right-sided tumors (13.8% and 12.8% for left-sided tumors versus 3.9% and 4.2% for right-sided tumors in the BCT group and the mastectomy group, respectively; p < 0.0001). There was no statistically significant difference in IMC contribution depending on the initial surgical procedure. IMC RT contributes to cardiac dose for both left-sided and right-sided breast cancers, although the relative contribution is greater in patients with left-sided tumors.

  5. Treatment of carcinoma of uterine cervix with high-dose-rate intracavitary irradiation using Ralstron

    International Nuclear Information System (INIS)

    Suh, C.O.; Kim, G.E.; Loh, J.J.K.

    1988-01-01

    From May 1979 through December 1981, a total of 530 patients with carcinoma of the uterine cervix were treated with radiation therapy with curative intent. Of the 530 patients, 365 were treated with a high-dose-rate remote-controlled afterloading system (RALS) using a cobalt source, and 165 patients received a low dose rate using a radium source. External pelvic irradiation with a total of 40-50 Gy to the whole pelvis followed by intracavitary radiation (ICR) with a total dose of 30-39 Gy in ten to 13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rate with high-dose-rate ICR by stage was as follows: stage I:82.7% (N = 19) stage II:69.6% (N = 184), and stage III:52.2% (N = 156). The above results were comparable with those with conventional low-dose-rate ICR treatment, and late complications were far less. The application of high-dose-rate ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually none as compared with that of low-dose-rate ICR. Within a given period of time, more patients can be treated with high-dose-rate ICR because of the short treatment time. The authors therefore conclude that high-dose-rate ICR is suitable for a cancer center where a large number of patients are to be treated

  6. Simple Finite Sums

    KAUST Repository

    Alabdulmohsin, Ibrahim M.

    2018-01-01

    We will begin our treatment of summability calculus by analyzing what will be referred to, throughout this book, as simple finite sums. Even though the results of this chapter are particular cases of the more general results presented in later chapters, they are important to start with for a few reasons. First, this chapter serves as an excellent introduction to what summability calculus can markedly accomplish. Second, simple finite sums are encountered more often and, hence, they deserve special treatment. Third, the results presented in this chapter for simple finite sums will, themselves, be used as building blocks for deriving the most general results in subsequent chapters. Among others, we establish that fractional finite sums are well-defined mathematical objects and show how various identities related to the Euler constant as well as the Riemann zeta function can actually be derived in an elementary manner using fractional finite sums.

  7. Simple Finite Sums

    KAUST Repository

    Alabdulmohsin, Ibrahim M.

    2018-03-07

    We will begin our treatment of summability calculus by analyzing what will be referred to, throughout this book, as simple finite sums. Even though the results of this chapter are particular cases of the more general results presented in later chapters, they are important to start with for a few reasons. First, this chapter serves as an excellent introduction to what summability calculus can markedly accomplish. Second, simple finite sums are encountered more often and, hence, they deserve special treatment. Third, the results presented in this chapter for simple finite sums will, themselves, be used as building blocks for deriving the most general results in subsequent chapters. Among others, we establish that fractional finite sums are well-defined mathematical objects and show how various identities related to the Euler constant as well as the Riemann zeta function can actually be derived in an elementary manner using fractional finite sums.

  8. Um mapeamento das aproximações entre Weber e Nietzsche

    Directory of Open Access Journals (Sweden)

    Leandro dos Santos

    2014-06-01

    Full Text Available Este artigo tem por objetivo um levantamento dos principais tópicos de aproximação entre a Sociologia de Max Weber (1864-1920 e a Filosofia de Friedrich W. Nietzsche (1844-1900. Para tanto, sublinharam-se os pontos mais expressivos e correntemente observados na literatura acerca das aproximações entre Weber e Nietzsche. Nesse sentido, os traços de maior afinidade foram encontrados nos seguintes temas: poder, conhecimento, modernidade e ética.

  9. Produtividade da cultura da melancia em função de fontes e doses de potássio Yield of watermelon fruits as a function of sources and doses of potassium

    Directory of Open Access Journals (Sweden)

    Arthur Bernardes Cecílio Filho

    2004-06-01

    Full Text Available Foram conduzidos dois experimentos em propriedades rurais próximas à cidade de Borborema - SP, nos períodos de outubro a dezembro de 2001 e de fevereiro a abril de 2002, com o objetivo de avaliar a produtividade de melancia (Citrullus lanatus (Thumb. Matsum. & Nakai, híbrido Tide, em função de fontes e doses de potássio. O delineamento experimental utilizado foi o de blocos casualizados completos, em esquema fatorial 3 x 4, com três repetições, sendo utilizadas as fontes: cloreto KCl, nitrato (KNO3 e sulfato de potássio (K2SO4 e as doses: 50; 100; 200 e 300 kg de K2O ha-1. Foram avaliados o peso médio de fruto, o número de frutos e produção por planta e produtividade. O maior número de frutos por planta estimado foi obtido nas doses de 190 e 300 kg K2O ha-1, respectivamente, nas fontes KNO3 e KCl. Não houve diferença significativa entre as doses para K2SO4. Para o peso médio de fruto, houve diferença significativa entre as fontes apenas no cultivo de fevereiro a abril de 2002, quando o KCl proporcionou maior peso. A maior produção por planta foi obtida com K2SO4, seguido por KNO3 e KCl. Entretanto, as doses de potássio para as máximas produtividades foram de 132, 193 e 205 kg K2O ha-1, respectivamente, para as fontes K2SO4, KNO3 e KCl. O plantio de outubro a dezembro de 2001 proporcionou maior peso médio, produção de frutos por planta e produtividade, ao passo que o maior número de frutos por planta foi obtido no cultivo de fevereiro a abril de 2002.Two field experiments were conducted in Borborema, State of São Paulo, from periods of October to December of the 2001 and February to April of 2002, with the objective of evaluate the yield of watermelon (Tide hybrid (Citrullus lanatus (Thumb. Matsum. & Nakai in function of sources and doses of potassium. The experimental design was a randomized complete block, with three replications, in a 3 x 4 factorial scheme, being evaluated sources: potassium chloride, nitrate and

  10. Autoconfrontação simples: condições de produção e autoconhecimento

    Directory of Open Access Journals (Sweden)

    Arlete Ribeiro Nepomuceno

    2010-07-01

    Full Text Available O presente artigo tem como objetivo refletir sobre a construção dos procedimentos discursivos depreendidos pela atividade de trabalho do defensor público no Tribunal do Júri, levando-se em conta a cenografia discursiva construída pela interação entre os participantes do Tribunal. Nessa veia, pretendemos contribuir para o autoconhecimento dos discursos sobre o trabalho, ajudar a elaborar essa formação linguageira e desenvolver dispositivos que ajudem o defensor a refletir sobre a sua fala. Os pressupostos teórico-metodológicos estão ancorados na Psicologia do Trabalho, com Clot (2005, Clot et al. (2001 e Clot e Faïta (2000; no método da autoconfrontação simples, com Clot (2005, Clot et al. (2001, Clot e Faïta (2000 e Faïta (2001; na Ergonomia, com os conceitos de prescrito/real: Clot (2005, Clot et al. (2001, Clot e Faïta (2000, bem como na Análise do Discurso, com Pêcheux (1975, 1990, 1997, Maingueneau (1997, 2002, 2005, Amossy (1999, Bakhtin (1995, 2003, Boutet (1995, entre outros. Concluímos que o método da autoconfrontação foi provocador de reflexões capazes de levar o defensor a externar o “difícil de dizer”, constitutivo de uma identidade que se ajusta ao seu papel social e o conduziu a reconhecer que, em seu trabalho, embora complexo, existem pontos positivos.

  11. Cyberbullying: competencia social, motivación y relaciones entre iguales

    Directory of Open Access Journals (Sweden)

    2016-07-01

    Full Text Available El reconocimiento de cierto solapamiento entre el acoso cara a cara (bullying y el ciberacoso (cyberbullying puede indicar que variables de cognición social, cuya influencia ha sido reconocida en el bullying, también estén presentes en el acoso cibernético. El objetivo de la investigación fue estudiar el ajuste social de los implicados en cyberbullying y analizar las diferencias en la percepción de la competencia social, la motivación y el apoyo de los iguales, entre víctimas, agresores y agresores victimizados del cyberbullying. Un total de 505 adolescentes (47,3% chicas con edades comprendidas entre los 12 y 16 años (M=13.95; DT=1.42 participaron en el estudio. Se utilizaron instrumentos para adolescentes validados en español y se analizaron las propiedades psicométricas para la adaptación de la escala de competencia social. Análisis factoriales exploratorios y confirmatorios mostraron índices óptimos de fiabilidad y validez. Se observó una mayor implicación de los ciberagresores victimizados. Las comparaciones entre roles a través de pruebas no paramétricas mostraron en los ciberagresores un mayor apoyo social que el resto de perfiles y altos niveles en metas de popularidad. Las cibervíctimas destacaron por su alta percepción de competencia social. Los ciberagresores victimizados mostraron altos niveles de metas de popularidad y baja aceptación social. Los resultados obtenidos permiten concluir que la forma en que el grupo de iguales gestiona su vida emocional y social puede estar explicando la situación de cyberbullying entre los adolescentes.

  12. Accuracy of two simple methods for estimation of thyroidal 131I kinetics for dosimetry-based treatment of Graves' disease

    International Nuclear Information System (INIS)

    Traino, A. C.; Xhafa, B.

    2009-01-01

    One of the major challenges to the more widespread use of individualized, dosimetry-based radioiodine treatment of Graves' disease is the development of a reasonably fast, simple, and cost-effective method to measure thyroidal 131 I kinetics in patients. Even though the fixed activity administration method does not optimize the therapy, giving often too high or too low a dose to the gland, it provides effective treatment for almost 80% of patients without consuming excessive time and resources. In this article two simple methods for the evaluation of the kinetics of 131 I in the thyroid gland are presented and discussed. The first is based on two measurements 4 and 24 h after a diagnostic 131 I administration and the second on one measurement 4 h after such an administration and a linear correlation between this measurement and the maximum uptake in the thyroid. The thyroid absorbed dose calculated by each of the two methods is compared to that calculated by a more complete 131 I kinetics evaluation, based on seven thyroid uptake measurements for 35 patients at various times after the therapy administration. There are differences in the thyroid absorbed doses between those derived by each of the two simpler methods and the ''reference'' value (derived by more complete uptake measurements following the therapeutic 131 I administration), with 20% median and 40% 90-percentile differences for the first method (i.e., based on two thyroid uptake measurements at 4 and 24 h after 131 I administration) and 25% median and 45% 90-percentile differences for the second method (i.e., based on one measurement at 4 h post-administration). Predictably, although relatively fast and convenient, neither of these simpler methods appears to be as accurate as thyroid dose estimates based on more complete kinetic data.

  13. Entre formigas e estrelas

    Directory of Open Access Journals (Sweden)

    Vinicius Prates

    2013-06-01

    Full Text Available Esta resenha apresenta o livro Reagregando o social: uma introdução à teoria do ator-rede, última obra do filósofo francês Bruno Latour publicada no Brasil. Nele, o autor se propõe a elaborar uma suma da crítica que faz aos conceitos usualmente aceitos de “social”, o que vem desenvolvendo ao longo dos últimos anos de produção intelectual. Neste processo ele criou a “Teoria-ator-rede”, que busca reestabelecer teoricamente as relações entre o que chama de mediadores “humanos” e “não-humanos”.

  14. Software for the estimation of organ equivalent and effective doses from diagnostic radiology procedures

    International Nuclear Information System (INIS)

    Osei, Ernest K; Barnett, Rob

    2009-01-01

    Diagnostic radiological imaging such as conventional radiography, fluoroscopy and computed tomography (CT) examinations will continue to provide tremendous benefits in modern healthcare. The benefit derived by the patient should far outweigh the risk associated with a properly conducted imaging examination. Nonetheless, it is very important to be able to quantify the risk associated with any radiological examination of patients, and effective dose has been considered a useful indicator of patient exposure. Quantification of the risks associated with radiological imaging is very important as such information will be helpful to physicians and their patients for comparing risks from various imaging examinations and for making informed decisions whenever there is a need for any radiological imaging. The determination of equivalent and effective doses in diagnostic radiology is of interest as a basis for estimates of risk from medical exposures. In this paper we describe a simple computer program OrgDose, which calculates the doses to 27 organs in the body and then calculates the organ equivalent and effective doses and the risk from various procedures in the radiology department including conventional radiography, fluoroscopy and computed tomography examinations. The program will be a useful tool for the medical and paramedical personnel who are involved with assessing organ and effective doses and risks from diagnostic radiology procedures.

  15. High-dose nifuratel for simple and mixed aerobic vaginitis: A single-center prospective open-label cohort study.

    Science.gov (United States)

    Liang, Qian; Li, Nan; Song, Shurong; Zhang, Aihua; Li, Ni; Duan, Ying

    2016-10-01

    The efficacy and safety of two nifuratel dosages for the treatment of aerobic vaginitis (AV) were compared. This was a prospective open-label cohort study of patients diagnosed and treated at the Tianjin Third Central Hospital between January 2012 and December 2013. The co-presence of bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), or/and trichomonal vaginitis (TV; mixed AV) was determined. Patients were randomized to nifuratel-500 (500 mg nifuratel, intravaginal, 10 days) or nifuratel-250 (250 mg nifuratel, intravaginal, 10 days), and followed-up for three to seven days after treatment completion. Primary and secondary outcomes were recovery rate and adverse events, respectively. The study included 142 patients with AV. Age was not significantly different between the groups (n = 71 each), and disease distribution was identical: 29 (40.85%) simple AV and 42 (59.15%) mixed AV (AV + BV, 42.86 %; AV + VVC, 30.95%; AV + TV, 26.19%). In patients with simple AV, the recovery rate did not differ significantly between the nifuratel-500 (26/29, 89.66%) and nifuratel-250 (22/29, 75.86%) groups. In patients with mixed AV, recovery rates were significantly higher in the nifuratel-500 than in the nifuratel-250 group (AV + BV, 88.89% vs 50.00 %; AV + VVC, 76.92 % vs 30.77 %; AV + TV, 90.91 % vs 36.36%; all P < 0.05). Only one patient (nifuratel-500) reported an adverse event (mild anaphylactic reaction). Nifuratel 500 mg showed good clinical efficacy for the treatment of AV, particularly mixed AV, and is superior to the 250 mg dosage in the treatment of mixed AV. © 2016 Japan Society of Obstetrics and Gynecology.

  16. Approximate distribution of dose among foetal organs for radioiodine uptake via placenta transfer

    Science.gov (United States)

    Millard, R. K.; Saunders, M.; Palmer, A. M.; Preece, A. W.

    2001-11-01

    Absorbed radiation doses to internal foetal organs were calculated according to the medical internal radiation dose (MIRD) technique in this study. Anthropomorphic phantoms of the pregnant female as in MIRDOSE3 enabled estimation of absorbed dose to the whole foetus at two stages of gestation. Some foetal organ self-doses could have been estimated by invoking simple spherical models for thyroid, liver, etc, but we investigated the use of the MIRDOSE3 new-born phantom as a surrogate for the stage 3 foetus, scaled to be compatible with total foetal body mean absorbed dose/cumulated activity. We illustrate the method for obtaining approximate dose distribution in the foetus near term following intake of 1 MBq of 123I, 124I, 125I or 131I as sodium iodide by the mother using in vivo biodistribution data examples from a good model of placenta transfer. Doses to the foetal thyroid of up to 1.85 Gy MBq-1 were predicted from the 131I uptake data. Activity in the foetal thyroid was the largest contributor to absorbed dose in the foetal body, brain, heart and thymus. Average total doses to the whole foetus ranged from 0.16 to 1.2 mGy MBq-1 for stages 1 and 3 of pregnancy using the MIRDOSE3 program, and were considerably higher than those predicted from the maternal contributions alone. Doses to the foetal thymus and stomach were similar, around 2-3 mGy MBq-1. Some foetal organ doses from the radioiodides were ten times higher than to the corresponding organs of the mother, and up to 100 times higher to the thyroid. The fraction of activity uptakes in foetal organs were distributed similarly to the maternal ones.

  17. Approximate distribution of dose among foetal organs for radioiodine uptake via placenta transfer

    Energy Technology Data Exchange (ETDEWEB)

    Millard, R.K. [Medical Physics Research Centre, Bristol Oncology Centre, Bristol (United Kingdom)]. E-mail: rkmillard_69@yahoo.co.uk; Saunders, M.; Palmer, A.M.; Preece, A.W. [Medical Physics Research Centre, Bristol Oncology Centre, Bristol (United Kingdom)

    2001-11-01

    Absorbed radiation doses to internal foetal organs were calculated according to the medical internal radiation dose (MIRD) technique in this study. Anthropomorphic phantoms of the pregnant female as in MIRDOSE3 enabled estimation of absorbed dose to the whole foetus at two stages of gestation. Some foetal organ self-doses could have been estimated by invoking simple spherical models for thyroid, liver, etc, but we investigated the use of the MIRDOSE3 new-born phantom as a surrogate for the stage 3 foetus, scaled to be compatible with total foetal body mean absorbed dose/cumulated activity. We illustrate the method for obtaining approximate dose distribution in the foetus near term following intake of 1 MBq of {sup 123}I, {sup 124}I, {sup 125}I or {sup 131}I as sodium iodide by the mother using in vivo biodistribution data examples from a good model of placenta transfer. Doses to the foetal thyroid of up to 1.85 Gy MBq{sup -1} were predicted from the {sup 131}I uptake data. Activity in the foetal thyroid was the largest contributor to absorbed dose in the foetal body, brain, heart and thymus. Average total doses to the whole foetus ranged from 0.16 to 1.2 mGy MBq{sup -1} for stages 1 and 3 of pregnancy using the MIRDOSE3 program, and were considerably higher than those predicted from the maternal contributions alone. Doses to the foetal thymus and stomach were similar, around 2-3 mGy MBq{sup -1}. Some foetal organ doses from the radioiodides were ten times higher than to the corresponding organs of the mother, and up to 100 times higher to the thyroid. The fraction of activity uptakes in foetal organs were distributed similarly to the maternal ones. (author)

  18. Estudo da resistência do tendão do supra-espinal com pontos simples, duplos e Mason Allen Study on the resistance of the supraspinous tendon using simple, matress and mason allen stitches

    Directory of Open Access Journals (Sweden)

    Roberto Yukio Ikemoto

    2010-01-01

    Full Text Available OBJETIVO: O objetivo do trabalho foi comparar a resistência entre os pontos simples, duplo e Mason-Allen modificado, utilizados para o reparo do manguito rotador, e verificar se há diferença significativa que justifique a utilização do ponto do tipo Mason-Allen modificado ao invés dos pontos simples ou duplo. MÉTODO: Retiramos tendões do músculo supra-espinal de 15 cadáveres humanos frescos (30 ombros, com a média de idade de 45 anos. Os testes foram realizados na máquina universal de ensaio mecânico Kratos® 500/2000 e os resultados submetidos aos testes estatísticos de t-student, análise de variância (ANOVA, comparação múltipla de Bonferroni e calculadas as correlações de Pearson. Os testes foram realizados ao nível de significância de 5%. RESULTADOS: Não houve diferença significativa com relação à idade, ao tamanho das amostras e deslocamento do tendão. A resistência variou com média de 127,50 N com o ponto simples, 163,95 N com o duplo e com o ponto de Mason-Allen modificado esta foi de 198,45 N. CONCLUSÃO: não existe diferença da resistência no tendão quanto à falha na interface sutura - tendão comparando-se o ponto duplo com o Mason-Allen modificado e os pontos simples e duplo, porém há diferença quando comparados os pontos simples e Mason-Allen modificado.OBJECTIVE: The purpose of this study was to compare the rotator cuff tendon resistance at the interface tendon-suture using three different sorts of stitches (simple, mattress and modified Mason-Allen. METHODS: To do this, 30 rotator cuffs were totally dissected from 15 specimens, which were 45 years old on average. The tests were done using a Kratos® 500/2000 machine and the statistical analyses applied were the Student t-test, ANOVA test, Multiple Bonferroni Comparison, and Pearson's correlation coefficients; all the analyses used a significance level of 5%. RESULTS: No significant difference was observed regarding the age, sample sizes and

  19. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  20. Caffeine Citrate Dosing Adjustments to Assure Stable Caffeine Concentrations in Preterm Neonates.

    Science.gov (United States)

    Koch, Gilbert; Datta, Alexandre N; Jost, Kerstin; Schulzke, Sven M; van den Anker, John; Pfister, Marc

    2017-12-01

    To identify dosing strategies that will assure stable caffeine concentrations in preterm neonates despite changing caffeine clearance during the first 8 weeks of life. A 3-step simulation approach was used to compute caffeine doses that would achieve stable caffeine concentrations in the first 8 weeks after birth: (1) a mathematical weight change model was developed based on published weight distribution data; (2) a pharmacokinetic model was developed based on published models that accounts for individual body weight, postnatal, and gestational age on caffeine clearance and volume of distribution; and (3) caffeine concentrations were simulated for different dosing regimens. A standard dosing regimen of caffeine citrate (using a 20 mg/kg loading dose and 5 mg/kg/day maintenance dose) is associated with a maximal trough caffeine concentration of 15 mg/L after 1 week of treatment. However, trough concentrations subsequently exhibit a clinically relevant decrease because of increasing clearance. Model-based simulations indicate that an adjusted maintenance dose of 6 mg/kg/day in the second week, 7 mg/kg/day in the third to fourth week and 8 mg/kg/day in the fifth to eighth week assures stable caffeine concentrations with a target trough concentration of 15 mg/L. To assure stable caffeine concentrations during the first 8 weeks of life, the caffeine citrate maintenance dose needs to be increased by 1 mg/kg every 1-2 weeks. These simple adjustments are expected to maintain exposure to stable caffeine concentrations throughout this important developmental period and might enhance both the short- and long-term beneficial effects of caffeine treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Extracranial stereotactic radiotherapy: Evaluation of PTV coverage and dose conformity

    International Nuclear Information System (INIS)

    Haedinger, U.; Thiele, W.; Wulf, J.

    2002-01-01

    During the past few years the concept of cranial sterotactic radiotherapy has been successfully extended to extracranial tumoral targets. In our department, hypofractionated treatment of tumours in lung, liver, abdomen, and pelvis is performed in the Stereotactic Body Frame (ELEKTA Instrument AB) since 1997. We present the evaluation of 63 consecutively treated targets (22 lung, 21 liver, 20 abdomen/pelvis) in 58 patients with respect to dose coverage of the planning target volume (PTV) as well as conformity of the dose distribution. The mean PTV coverage was found to be 96.3%±2.3% (lung), 95.0%±4.5% (liver), and 92.1%±5.2% (abdomen/pelvis). For the so-called conformation number we obtained values of 0.73±0.09 (lung), 0.77±0.10 (liver), and 0.70±0.08 (abdomen/pelvis). The results show that highly conformal treatment techniques can be applied also in extracranial stereotactic radiotherapy. This is primarily due to the relatively simple geometrical shape of most of the targets. Especially lung and liver targets turned out to be approximately spherically/cylindrically shaped, so that the dose distribution can be easily tailored by rotational fields. (orig.) [de

  2.  Papas Alexandre, Soufisme et politique entre Chine, Tibet et Turkestan, Librairie d'Amérique et d'Orient, Jean Maisonneuve, 2005, 291 p.

    Directory of Open Access Journals (Sweden)

    Catherine Mayeur-Jaouen

    2009-05-01

    Full Text Available Fondé sur la lecture de nombreuses sources essentiellement manuscrites (18 manuscrits d’accès souvent difficile en turc tchagatay ou en persan, chroniques du Turkestan ou hagiographies, Soufisme et politique entre Chine, Tibet et Turkestan publie une thèse qui fut couronnée en 2006 du prix de l’IISMMM pour la meilleure thèse sur le monde musulman. L’argument en est simple : « en 1679, le saint naqshbandî Âfâq Khwâja, descendant du grand saint de Samarcande Makhdûm-i A‘zam (m. 1542, fonde un...

  3. The Fast-Casual Conundrum: Fast-Casual Restaurant Entrées Are Higher in Calories than Fast Food.

    Science.gov (United States)

    Schoffman, Danielle E; Davidson, Charis R; Hales, Sarah B; Crimarco, Anthony E; Dahl, Alicia A; Turner-McGrievy, Gabrielle M

    2016-10-01

    Frequently eating fast food has been associated with consuming a diet high in calories, and there is a public perception that fast-casual restaurants (eg, Chipotle) are healthier than traditional fast food (eg, McDonald's). However, research has not examined whether fast-food entrées and fast-casual entrées differ in calorie content. The purpose of this study was to determine whether the caloric content of entrées at fast-food restaurants differed from that found at fast-casual restaurants. This study was a cross-sectional analysis of secondary data. Calorie information from 2014 for lunch and dinner entrées for fast-food and fast-casual restaurants was downloaded from the MenuStat database. Mean calories per entrée between fast-food restaurants and fast-casual restaurants and the proportion of restaurant entrées that fell into different calorie ranges were assessed. A t test was conducted to test the hypothesis that there was no difference between the average calories per entrée at fast-food and fast-casual restaurants. To examine the difference in distribution of entrées in different calorie ranges between fast-food and fast-casual restaurants, χ(2) tests were used. There were 34 fast-food and 28 fast-casual restaurants included in the analysis (n=3,193 entrées). Fast-casual entrées had significantly more calories per entrée (760±301 kcal) than fast-food entrées (561±268; Prestaurants to determine whether the energy content or nutrient density of full meals (ie, entrées with sides and drinks) differs between fast-casual restaurants and fast-food restaurants. Calorie-conscious consumers should consider the calorie content of entrée items before purchase, regardless of restaurant type. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  4. Determination of organ doses and effective doses in radiooncology

    International Nuclear Information System (INIS)

    Roth, J.; Martinez, A.E.

    2007-01-01

    Background and Purpose: With an increasing chance of success in radiooncology, it is necessary to estimate the risk from radiation scatter to areas outside the target volume. The cancer risk from a radiation treatment can be estimated from the organ doses, allowing a somewhat limited effective dose to be estimated and compared. Material and Methods: The doses of the radiation-sensitive organs outside the target volume can be estimated with the aid of the PC program PERIDOSE developed by van der Giessen. The effective doses are determined according to the concept of ICRP, whereby the target volume and the associated organs related to it are not taken into consideration. Results: Organ doses outside the target volume are generally < 1% of the dose in the target volume. In some cases, however, they can be as high as 3%. The effective doses during radiotherapy are between 60 and 900 mSv, depending upon the specific target volume, the applied treatment technique, and the given dose in the ICRU point. Conclusion: For the estimation of the radiation risk, organ doses in radiooncology can be calculated with the aid of the PC program PERIDOSE. While evaluating the radiation risk after ICRP, for the calculation of the effective dose, the advanced age of many patients has to be considered to prevent that, e.g., the high gonad doses do not overestimate the effective dose. (orig.)

  5. Initial dosimetric experience using simple three-dimensional conformal external-beam accelerated partial-breast irradiation

    International Nuclear Information System (INIS)

    Taghian, Alphonse G.; Kozak, Kevin R.; Doppke, Karen P.; Katz, Angela; Smith, Barbara L.; Gadd, Michele; Specht, Michelle; Hughes, Kevin; Braaten, Kristina; Kachnic, Lisa A.; Recht, Abram; Powell, Simon N.

    2006-01-01

    Purpose: Several accelerated partial-breast irradiation (APBI) techniques are being investigated in patients with early-stage breast cancer. We present our initial experience using three-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: Sixty-one patients with tumors of 2 cm or less and negative axillary nodes were treated with 3D-CRT accelerated partial-breast irradiation (APBI) between August 2003 and March 2005. The prescribed radiation dose was 32 Gy in 4-Gy fractions given twice daily. Efforts were made to minimize the number of beams required to achieve adequate planning target volume (PTV) coverage. Results: A combination of photons and electrons was used in 85% of patients. A three-field technique that consisted of opposed, conformal tangential photons and enface electrons was employed in 43 patients (70%). Nine patients (15%) were treated with a four-field arrangement, which consisted of three photon fields and enface electrons. Mean PTV volumes that received 100%, 95%, and 90% of the prescribed dose were 93% ± 7%, 97% ± 4%, and 98% ± 2%, respectively. Dose inhomogeneity exceeded 10% in only 7 patients (11%). Mean doses to the ipsilateral lung and heart were 1.8 Gy and 0.8 Gy, respectively. Conclusions: Simple 3D-CRT techniques of APBI can achieve appropriate PTV coverage while offering significant normal-tissue sparing. Therefore, this noninvasive approach may increase the availability of APBI to patients with early-stage breast cancer

  6. Teores de macronutrientes em melancias fertirrigadas com diferentes doses de nitrogênio e potássio

    Directory of Open Access Journals (Sweden)

    Max Venicius Teixeira da Silva

    2014-07-01

    Full Text Available 800x600 A melancieira é uma planta cultivada praticamente em quase todo o Brasil, desde regiões mais frias do Rio Grande do Sul até regiões mais quentes do Nordeste brasileiro. O trabalho teve como objetivo avaliar os teores de macronutrientes (N, P e K na folha sob diferentes doses de nitrogênio e potássio via fertirrigação nas cultivares de melancia Quetzali (Com sementes e Leopard (Sem sementes. O experimento, com as duas variedades de melancia, foi conduzido no delineamento experimental em blocos casualizados no esquema de parcelas subdivididas 13 x 2, sendo o primeiro fator representado pela combinação de doses de nitrogênio (N e potássio (K em arranjo definido segundo o modelo: 2 x 2k + 2k + 1, sendo k o número de fatores estudados (N e K. A ordem decrescente dos macronutrientes acumulados pela cultivar Quetzali seguiu a seguinte sequência: N>K e P, já a Leopard seguiu a ordem: K, N e P, a cultivar Quetzali acumulou sua maior quantidade de nutrientes entre 15 a 35 Dias ápos o transplantio (DAT, enquanto a cultivar Leopard acumulou grande parte dos  nutrientes entre 15 a 45 DAT, a cultivar Leopard teve uma maior resposta a plicação de N e K, quando comparado a Quetzali. Normal 0 21 false false false PT-BR X-NONE X-NONE Radioimmunoassay evaluation and quality control by use of a simple computer program for a low cost desk top calculator

    International Nuclear Information System (INIS)

    Schwarz, S.

    1980-01-01

    A simple computer program for the data processing and quality control of radioimmunoassays is presented. It is written for low cost programmable desk top calculator (Hewlett Packard 97), which can be afforded by smaller laboratories. The untreated counts from the scintillation spectrometer are entered manually; the printout gives the following results: initial data, logit-log transformed calibration points, parameters of goodness of fit and of the position of the standard curve, control and unknown samples dose estimates (mean value from single dose interpolations and scatter of replicates) together with the automatic calculation of within assay variance and, by use of magnetic cards holding the control parameters of all previous assays, between assay variance. (orig.) [de

  7. Computation of mean and variance of the radiotherapy dose for PCA-modeled random shape and position variations of the target.

    Science.gov (United States)

    Budiarto, E; Keijzer, M; Storchi, P R M; Heemink, A W; Breedveld, S; Heijmen, B J M

    2014-01-20

    Radiotherapy dose delivery in the tumor and surrounding healthy tissues is affected by movements and deformations of the corresponding organs between fractions. The random variations may be characterized by non-rigid, anisotropic principal component analysis (PCA) modes. In this article new dynamic dose deposition matrices, based on established PCA modes, are introduced as a tool to evaluate the mean and the variance of the dose at each target point resulting from any given set of fluence profiles. The method is tested for a simple cubic geometry and for a prostate case. The movements spread out the distributions of the mean dose and cause the variance of the dose to be highest near the edges of the beams. The non-rigidity and anisotropy of the movements are reflected in both quantities. The dynamic dose deposition matrices facilitate the inclusion of the mean and the variance of the dose in the existing fluence-profile optimizer for radiotherapy planning, to ensure robust plans with respect to the movements.

  8. Computation of mean and variance of the radiotherapy dose for PCA-modeled random shape and position variations of the target

    International Nuclear Information System (INIS)

    Budiarto, E; Keijzer, M; Heemink, A W; Storchi, P R M; Breedveld, S; Heijmen, B J M

    2014-01-01

    Radiotherapy dose delivery in the tumor and surrounding healthy tissues is affected by movements and deformations of the corresponding organs between fractions. The random variations may be characterized by non-rigid, anisotropic principal component analysis (PCA) modes. In this article new dynamic dose deposition matrices, based on established PCA modes, are introduced as a tool to evaluate the mean and the variance of the dose at each target point resulting from any given set of fluence profiles. The method is tested for a simple cubic geometry and for a prostate case. The movements spread out the distributions of the mean dose and cause the variance of the dose to be highest near the edges of the beams. The non-rigidity and anisotropy of the movements are reflected in both quantities. The dynamic dose deposition matrices facilitate the inclusion of the mean and the variance of the dose in the existing fluence-profile optimizer for radiotherapy planning, to ensure robust plans with respect to the movements. (paper)

  9. Dose measurement of fast electrons with a modified Fricke solution

    International Nuclear Information System (INIS)

    Nemec, H.W.; Roth, J.; Luethy, H.

    1975-01-01

    A combination of two different modifications indicated in the literature about the ferrosulfate dosimetry is given. This permits a dose measurement which shows compared to the usual Fricke dosimetry above all following advantages: dose specification related to water; displacement of the absorption maximum in the perceptible spectral sphere; increase of the sensibility and lower influence of pollutions. The molar coefficient of extinction of the modified solution has been determined from 60 Co gamma irradiation and is epsilonsub(m) = 1.46 x 10 4 l x Mol -1 x cm -1 . The increase of extinction which has been measured with this method after the irradiation with 18 MeV electrons occurs linearly within the studied region to 1,200 rd at least, the G-value is 15.5. The indicated method renders possible a relative simple calibration of the ionization chambers used in the practice. (orig.) [de

  10. Differences between cross-section libraries for neutron dosimetry; Diferencas entre bibliotecas de secoes de choque para dosimetria de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Tardelli, T.C.; Stecher, L.C.; Coelho, T.S.; Castro, V.A. De; Cavalieri, T.A.; Menzel, F.; Giarola, R.S.; Domingos, D.B.; Yoriyaz, H., E-mail: tiago.tardelli@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Engenharia Nuclear

    2013-08-15

    Absorbed dose calculations depend on a consistent set of nuclear data used in simulations in computer codes. Nuclear data are stored in libraries, however, the information available about the differences in dose caused by different libraries are rare. The libraries are processed by a computer system to be able to be used by a radiation transport code. One of the systems capable of processing nuclear data is the NJOY system. The objective of this study is to evaluate the nuclear data libraries for neutrons available in the literature, and to quantify the differences in absorbed dose obtained using the libraries JENDL 4.0, JEFF 3.3.1 and ENDF/B.VII. The absorbed dose calculation was performed on a simple geometric model, as spheres, and in anthropomorphic model of the human body based on the ICRP-110 for neutron transport simulation using the MCNP5 code. The results were compared with literature data. The results obtained with cross sections from the libraries JEFF and ENDF/B.VII have shown to be identical in most cases, except for one case where the difference has exceeded 10%. The results obtained with JENDL library has shown to be considerably different in most cases comparing to other two libraries. Some differences were over 200%. The dose calculations showed differences between the libraries, which is justified by differences in the cross sections. It has been observed that the cross sections values of certain nuclides assume quite different values in different libraries. These differences in turn cause considerable differences in dose calculations. (author)

  11. Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques

    Science.gov (United States)

    Yoon, Jihyung; Heins, David; Zhao, Xiaodong; Sanders, Mary; Zhang, Rui

    2017-12-01

    More and more advanced radiotherapy techniques have been adopted for post-mastectomy radiotherapies (PMRT). Patient dose reconstruction is challenging for these advanced techniques because they increase the low out-of-field dose area while the accuracy of out-of-field dose calculations by current commercial treatment planning systems (TPSs) is poor. We aim to measure and model the out-of-field radiation doses from various advanced PMRT techniques. PMRT treatment plans for an anthropomorphic phantom were generated, including volumetric modulated arc therapy with standard and flattening-filter-free photon beams, mixed beam therapy, 4-field intensity modulated radiation therapy (IMRT), and tomotherapy. We measured doses in the phantom where the TPS calculated doses were lower than 5% of the prescription dose using thermoluminescent dosimeters (TLD). The TLD measurements were corrected by two additional energy correction factors, namely out-of-beam out-of-field (OBOF) correction factor K OBOF and in-beam out-of-field (IBOF) correction factor K IBOF, which were determined by separate measurements using an ion chamber and TLD. A simple analytical model was developed to predict out-of-field dose as a function of distance from the field edge for each PMRT technique. The root mean square discrepancies between measured and calculated out-of-field doses were within 0.66 cGy Gy-1 for all techniques. The IBOF doses were highly scattered and should be evaluated case by case. One can easily combine the measured out-of-field dose here with the in-field dose calculated by the local TPS to reconstruct organ doses for a specific PMRT patient if the same treatment apparatus and technique were used.

  12. Avaliação da atividade "in vivo" da fosfatase ácida e do crescimento de progênies de pupunheira cultivadas em duas doses de nitrogênio e fósforo

    Directory of Open Access Journals (Sweden)

    M. L. A. Bovi

    1998-09-01

    Full Text Available O presente trabalho, realizado em janeiro de 1995, visou avaliar a atividade da enzima fosfatase ácida em folhas de quatro progênies de pupunheira (Bactris gasipaes Kunth, cultivadas em duas doses de nitrogênio e duas de fósforo. Para tanto, utilizou-se a porção média da segunda folha mais jovem de perfilhos de palmeiras com quatro anos de idade. As plantas analisadas representam parcelas submetidas a duas doses de nitrogênio (N1 = 0, N2 = 400 kg ha-1 ano-1 de N e duas doses de fósforo (P1 = 0, P2 = 200 kg ha-1 ano-1 de P2O5. A dose de potássio foi 200 kg ha-1 ano-1 de K2O. Análises dos elementos no solo e nas folhas foram efetuadas e correlações foram estimadas entre as características avaliadas e o crescimento e a produção de palmito dos quatro tratamentos. Foram observados valores médios de atividade da fosfatase ácida de 8,35; 4,58; 10,84, e 11,05 µmol h-1 g-1, para os tratamentos N2P2, N2P1, N1P2 e N1P1, respectivamente. Houve diferenças significativas de atividade entre doses de nitrogênio (10,95 e 6,47 µmol h-1 g-1, para N1 e N2, respectivamente e entre progênies (variando de 6,18 (G3 a 10,10 (G1 µmol h-1 g-1, indicando que esses dois fatores devem ser levados em conta em estudos dessa natureza. A atividade da fosfatase ácida apresentou correlação negativa com as características que avaliam o crescimento (biomassa aérea e radicular e a produção de palmito (peso e diâmetro das plantas estudadas, não se correlacionando com os teores de fósforo no solo ou no tecido foliar.

  13. Estimation of doses to individuals from radionuclides disposed of in Solid Waste Storage Area 6

    International Nuclear Information System (INIS)

    Fields, D.E.; Boegly, W.J. Jr.; Huff, D.D.

    1986-01-01

    A simple methodology has been applied to estimate maximum possible doses to individuals from exposure to radionuclides released from Solid Waste Storage Area No. 6. This is the only operating shallow-land disposal site for radioactive waste at the Oak Ridge National Laboratory. The methodology is based upon simple, conservative assumptions. A data base of radionuclides disposed of in trenches and auger holes was prepared, and several radionuclide transport and ingestion scenarios were considered. The results of these simulations demonstrate the potential for adverse health effects associated with this waste disposal area, and support the need for further calculations using more complete and realistic assumptions

  14. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  15. Cálculo de Kt/V em hemodiálise: comparação entre fórmulas

    Directory of Open Access Journals (Sweden)

    Guilherme Breitsameter

    2012-03-01

    Full Text Available INTRODUÇÃO: A qualidade da diálise oferecida aos pacientes em diálise pode ser mensurada pelo Kt/V, o qual pode ser calculado de diversas maneiras. OBJETIVO: Comparar os resultados de Kt/V obtidos por meio das fórmulas de Lowrie (L e de Daugirdas (D com os resultados mensurados pelo monitor de clearence on-line - Online Clearence Monitor (OCM. MÉTODO: Estudo observacional transversal com 59 pacientes em hemodiálise (HD. Os dados foram coletados na mesma sessão de diálise: (ureia pré-diálise e pós-diálise e o resultado de Kt/V foi obtido pelo OCM da máquina Fresenius 4008S (Fresenius Medical Care AG, Bad Homburg, Alemanha. RESULTADO: Foram analisadas 95 sessões, em que prevaleceu o sexo masculino, 56% (33, com idade média de 57 + 14 anos. A hipertensão arterial com 42% (25, diabetes com 12% (7 e glomerulonefrite com 8% (5 foram as causas mais frequentes da doença renal crônica (DRC. O Kt/V médio obtido pela fórmula de L, de D e pelo OCM foi de 1,31; 1,41 e 1,32, respectivamente. A comparação entre as fórmulas de L e D mostra que há diferença estatística p = 0,008 com a correlação de Pearson de 0,950. Entre D e OCM a diferença também é significativa: p = 0,011 e r = 0,346, provavelmente devido a perda convectiva, avaliada pela equação de D e não observadas por OCM e L. A comparação entre L e OCM não foi significativa p = 0,999 e r = 0,577. CONCLUSÃO: Os dados sugerem que o OCM pode ser utilizado como um norteador para ajuste da dose de diálise em tempo real.

  16. Interactions entre muqueuse orale, salive et molécules de la flaveur

    OpenAIRE

    Ployon, Sarah

    2016-01-01

    Le rôle de la salive dans la perception sensorielle est de plus en plus reconnu, notamment par le biais des interactions physico-chimiques pouvant s’établir entre protéines salivaires et constituants alimentaires. Ce travail s’intéresse à la pellicule salivaire, la couche de protéines salivaires ancrées aux cellules épithéliales, et vise à caractériser les interactions pouvant s’établir d’une part entre ces protéines et épithélium oral, et d‘autre part entre ces protéines et les molécules de ...

  17. Assessing mixed dose distributions in young sediments identified using small aliquots and a simple two-step SAR procedure: the F-statistic as a diagnostic tool

    International Nuclear Information System (INIS)

    Spencer, J.Q.; Sanderson, D.C.W.; Deckers, Katleen; Sommerville, A.A.

    2003-01-01

    In this study we have investigated the apparent dose (D e *) distribution in four samples of young sedimentary quartz from different depositional environments, and on standard quartz comprised of artificial binary-dose mixtures. We have used a simplified two-step single-aliquot regenerative-dose (SAR) approach to rapidly measure D e * from a large number of small aliquots (∼50-100 grains), with a small sub-set subjected to routine SAR measurements to enable monitoring of luminescence characteristics. We have used an F-ratio analysis to interpret D e * distributions. This analysis is sensitive to structure, the leading edge and modal data in D e * distributions, indicated by inflections and plateaux in F-ratio plots. We cautiously suggest that F-ratios at or approaching unity may indicate a single dose component

  18. Comparison of the predictions of the LQ and CRE models for normal tissue damage due to biologically targeted radiotherapy with exponentially decaying dose rates

    International Nuclear Information System (INIS)

    O'Donoghue, J.A.; West of Schotland Health Boards, Glasgow

    1989-01-01

    For biologically targeted radiotherapy organ dose rates may be complex functions of time, related to the biodistribution kinetics of the delivery vehicle and radiolabel. The simples situation is where dose rates are exponentially decaying functions of time. Two normal tissue isoeffect models enable the effects of exponentially decaying dose rates to be addressed. These are the extension of the linear-quadratic model and the cumulative radiation effect model. This communication will compare the predictions of these models. (author). 14 refs.; 1 fig

  19. Measurements and calculations of neutron spectra and neutron dose distribution in human phantoms

    International Nuclear Information System (INIS)

    Palfalvi, J.

    1984-11-01

    The measurement and calculation of the radiation field around and in a phantom, with regard to the neutron component and the contaminating gamma radiation, are essential for radiation protection and radiotherapy purposes. The final report includes the development of the simple detector system, automized detector measuring facilities and a computerized evaluating system. The results of the depth dose and neutron spectra experiments and calculations in a human phantom are given

  1. The influence of inhomogeneities on the dose distribution of fast electrons in radiotherapy

    International Nuclear Information System (INIS)

    Windemuth, M.

    1985-01-01

    Simple models are used to make a principal comparison between measured fast-electron dose distributions behind tissue inhomogeneities and those calculated by means of an irradiation planning system. The different organs were represented by water (for muscle), by cork (for the lungs) and by graphite (for bone). Corresponding to their density, inhomogeneities result, in principle, in a dose shift to a greater or smaller body depth which is correctly considered by the irradiation planning system. However, electron scattering transversal to beam direction will occur behind inhomogeneity edges which, in general, are not covered by the irradiation planning system, but which result in dose distributions deviating strongly from those expected as due to the shift. This is the reason for the limited accuracy of irradiation planning systems in complicated inhomogeneity distribution. The thesis demonstrates those cases which justify irradiation planning and those cases where they are not a reliable basis for irradiation. (orig./HP) [de

  2. Data base on dose reduction research projects for nuclear power plants: Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Khan, T.A.; Baum, J.W.

    1989-05-01

    This is the third volume in a series of reports that provide information on dose-reduction research and health physics technology for nuclear power plants. The information is taken from data base maintained by Brookhaven National Laboratory's ALARA Center for the Nuclear Regulatory Commission. This report presents information on 80 new projects, covering a wide area of activities. Projects on steam generator degradation, decontamination, robotics, improvement in reactor materials, and inspection techniques, among others, are described in the research section. The section on health physics technology includes some simple and very cost-effective projects to reduce radiation exposures. Collective dose data from the United States and other countries are also presented. In the conclusion, we suggest that although new advanced reactor design technology will eventually reduce radiation exposures at nuclear power plants to levels below serious concern, in the interim an aggressive approach to dose reduction remains necessary. 20 refs.

  3. Simple routine tests to improve the performance of the DPRSN TLD-based individual monitoring system

    International Nuclear Information System (INIS)

    Alves, J.G.; Batel, V.I.; Silva, P.B.; Roda, A.; Santos, L.

    2002-01-01

    This paper presents some of the results of a simple quality control program developed and implemented at the thermoluminescence sector of the IMS. The European Union (EU) Directive 96/29/EURATOM has not yet been transposed to national legislation and Portuguese law concerning the monitoring of radiation workers still establishes an annual dose limit of 50 mSv. However, new legislation has recently been published with requirements on the performance of dosimetric services. Some of the results of the tests reported herein will show compliance with the above mentioned requirements

  4. PAPEL DE LA CONFIANZA en las relaciones entre organizaciones

    Directory of Open Access Journals (Sweden)

    Irene Juana Guillén Mondragón

    2006-07-01

    Full Text Available El objetivo del presente documento es analizar las definiciones y la importancia de la confianza para crear relaciones de cooperación entre organizaciones de naturaleza distinta. Se hace referencia a los modelos de organización dominantes para acercarnos a los nuevos mecanismos de regulación social propuestos por la sociología para tratar la organización, debido a que en el contexto actual las nuevas concepciones de la organización del trabajo han promovido en las organizaciones formas distintas de competir en el mercado. Procesos de cambio que obligan a las organizaciones a construir una nueva identidad y a renovar los contratos psicológicos con sus integrantes. La noción de confianza ha sido llevada del ámbito social al organizacional con la finalidad de lograr acuerdos entre organizaciones y al mismo tiempo lograr el compromiso de los integrantes de tales entidades. Para que estas puedan funcionar bajo este marco de transformaciones requieren de relaciones de colaboración regidas por la  confianza; relaciones que se dan en los niveles individual, dentro de la organización, entre organizaciones e institucionalmente. Los diferentes niveles de confianza están presentes en las relaciones que entablan los individuos, tanto dentro de la organización como en su entorno. Algunas de las reflexiones en torno a esta problemática nos llevan a pensar que el papel de la confianza es dinámico e incide en la transferencia y el intercambio de conocimientos, técnicas y procedimientos científicos, tecnologías, productos, capitales, entre otros. Además, las relaciones fundadas en la confianza requieren de la suspensión del propio interés, en beneficio de unaorientación colectiva (Mangematin y Thuderoz, 2003. Sin embargo, también se reconoce que con todo y la posibilidad que el hombre tiene de deliberar y de generar confianza, es evidente que entre los hombres prevalecen tanto la confianza calculada como los deseos de altruismo para entrar

  5. Fractional dosing of yellow fever vaccine to extend supply: a modelling study.

    Science.gov (United States)

    Wu, Joseph T; Peak, Corey M; Leung, Gabriel M; Lipsitch, Marc

    2016-12-10

    The ongoing yellow fever epidemic in Angola strains the global vaccine supply, prompting WHO to adopt dose sparing for its vaccination campaign in Kinshasa, Democratic Republic of the Congo, in July-August, 2016. Although a 5-fold fractional-dose vaccine is similar to standard-dose vaccine in safety and immunogenicity, efficacy is untested. There is an urgent need to ensure the robustness of fractional-dose vaccination by elucidation of the conditions under which dose fractionation would reduce transmission. We estimate the effective reproductive number for yellow fever in Angola using disease natural history and case report data. With simple mathematical models of yellow fever transmission, we calculate the infection attack rate (the proportion of population infected over the course of an epidemic) with various levels of transmissibility and 5-fold fractional-dose vaccine efficacy for two vaccination scenarios, ie, random vaccination in a hypothetical population that is completely susceptible, and the Kinshasa vaccination campaign in July-August, 2016, with different age cutoff for fractional-dose vaccines. We estimate the effective reproductive number early in the Angola outbreak was between 5·2 and 7·1. If vaccine action is all-or-nothing (ie, a proportion of vaccine recipients receive complete protection [VE] and the remainder receive no protection), n-fold fractionation can greatly reduce infection attack rate as long as VE exceeds 1/n. This benefit threshold becomes more stringent if vaccine action is leaky (ie, the susceptibility of each vaccine recipient is reduced by a factor that is equal to the vaccine efficacy). The age cutoff for fractional-dose vaccines chosen by WHO for the Kinshasa vaccination campaign (2 years) provides the largest reduction in infection attack rate if the efficacy of 5-fold fractional-dose vaccines exceeds 20%. Dose fractionation is an effective strategy for reduction of the infection attack rate that would be robust with a

  6. Fractional Dosing of Yellow Fever Vaccine to Extend Supply: A Modeling Study

    Science.gov (United States)

    Peak, Corey M.; Leung, Gabriel M.

    2016-01-01

    Background The ongoing yellow fever (YF) epidemic in Angola strains the global vaccine supply, prompting WHO to adopt dose sparing for its vaccination campaign in Kinshasa in July–August 2016. Although a 5-fold fractional-dose vaccine is similar to standard-dose vaccine in safety and immunogenicity, efficacy is untested. There is an urgent need to ensure the robustness of fractional-dose vaccination by elucidating the conditions under which dose fractionation would reduce transmission. Methods We estimate the effective reproductive number for YF in Angola using disease natural history and case report data. With simple mathematical models of YF transmission, we calculate the infection attack rate (IAR, the proportion of population infected over the course of an epidemic) under varying levels of transmissibility and five-fold fractional-dose vaccine efficacy for two vaccination scenarios: (i) random vaccination in a hypothetical population that is completely susceptible; (ii) the Kinshasa vaccination campaign in July–August 2016 with different age cutoff for fractional-dose vaccines. Findings We estimate the effective reproductive number early in the Angola outbreak was between 5·2 and 7·1. If vaccine action is all-or-nothing (i.e. a proportion VE of vaccinees receives complete and the remainder receive no protection), n-fold fractionation can dramatically reduce IAR as long as efficacy VE exceeds 1/n. This benefit threshold becomes more stringent if vaccine action is leaky (i.e. the susceptibility of each vaccinee is reduced by a factor that is equal to the vaccine efficacy VE). The age cutoff for fractional-dose vaccines chosen by the WHO for the Kinshasa vaccination campaign (namely, 2 years) provides the largest reduction in IAR if the efficacy of five-fold fractional-dose vaccines exceeds 20%. Interpretation Dose fractionation is a very effective strategy for reducing infection attack rate that would be robust with a large margin for error in case

  7. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  8. Causalidade entre as principais bolsas de valores do mundo

    Directory of Open Access Journals (Sweden)

    Hiron Pereira Farias

    2010-04-01

    Full Text Available O objetivo deste trabalho foi analisar os mercados dos países emergentes que fazem parte do Bric, com exceção da Índia, buscando mostrar como os mercados do Brasil, da Rússia e China se comportam entre si e em relação ao mercado dos Estados Unidos. Analisou-se também como alguns países desenvolvidos do grupo G8, Estados Unidos, Reino Unido e Japão, se comportam. Em cada análise, ajustou-se um modelo VAR e buscou-se verificar o grau de dependência dentro e entre cada grupo, utilizando teste de causalidade de Granger, critérios de seleção de modelos, função resposta a impulso e decomposição da variância do erro de previsão. Nas análises realizadas, os mercados brasileiro e americano mostraram forte influência sobre os demais mercados, e, na análise entre os grupos, consideraram-se o mercado dos Estados Unidos do grupo ERJ e todos os mercados emergentes do grupo BRC. O mercado americano mostrou forte influência sobre os outros mercados.

  9. Simple prostatectomy

    Science.gov (United States)

    ... Han M, Partin AW. Simple prostatectomy: open and robot-assisted laparoscopic approaches. In: Wein AJ, Kavoussi LR, ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  10. Testing of the analytical anisotropic algorithm for photon dose calculation

    International Nuclear Information System (INIS)

    Esch, Ann van; Tillikainen, Laura; Pyykkonen, Jukka; Tenhunen, Mikko; Helminen, Hannu; Siljamaeki, Sami; Alakuijala, Jyrki; Paiusco, Marta; Iori, Mauro; Huyskens, Dominique P.

    2006-01-01

    The analytical anisotropic algorithm (AAA) was implemented in the Eclipse (Varian Medical Systems) treatment planning system to replace the single pencil beam (SPB) algorithm for the calculation of dose distributions for photon beams. AAA was developed to improve the dose calculation accuracy, especially in heterogeneous media. The total dose deposition is calculated as the superposition of the dose deposited by two photon sources (primary and secondary) and by an electron contamination source. The photon dose is calculated as a three-dimensional convolution of Monte-Carlo precalculated scatter kernels, scaled according to the electron density matrix. For the configuration of AAA, an optimization algorithm determines the parameters characterizing the multiple source model by optimizing the agreement between the calculated and measured depth dose curves and profiles for the basic beam data. We have combined the acceptance tests obtained in three different departments for 6, 15, and 18 MV photon beams. The accuracy of AAA was tested for different field sizes (symmetric and asymmetric) for open fields, wedged fields, and static and dynamic multileaf collimation fields. Depth dose behavior at different source-to-phantom distances was investigated. Measurements were performed on homogeneous, water equivalent phantoms, on simple phantoms containing cork inhomogeneities, and on the thorax of an anthropomorphic phantom. Comparisons were made among measurements, AAA, and SPB calculations. The optimization procedure for the configuration of the algorithm was successful in reproducing the basic beam data with an overall accuracy of 3%, 1 mm in the build-up region, and 1%, 1 mm elsewhere. Testing of the algorithm in more clinical setups showed comparable results for depth dose curves, profiles, and monitor units of symmetric open and wedged beams below d max . The electron contamination model was found to be suboptimal to model the dose around d max , especially for physical

  11. Simple improvement in the technique of hysterosalpingography achieving optimal imaging and avoiding possible complications

    International Nuclear Information System (INIS)

    Beyth, Y.; Navot, D.; Lax, E.

    1985-01-01

    A simple technique is reported in which oil-soluble contrast media (OSCM) are used with hysterosalpingography to investigate infertility in women due to uterine and tubal pathology. The advantages of OSCM as compared with water-soluble contrast media (WSCM) are described. Complications caused by intravasation of the OSCM into lymph vessels and veins are avoided by clearing the media at the end of the procedure. This also results in the immediate spread of the contrast media in the pelvic cavity with the result that delayed radiographs become superfluous and the radiation dose to the genitals is reduced. 4 references, 2 figures

  12. Factores de riesgo que condicionan la conducta machista entre adolescentes.

    OpenAIRE

    Sánchez Alonso, Isabel

    2016-01-01

    Este trabajo sobre los factores de riesgo que condicionan la violencia machista entre adolescentes, recoge las principales argumentaciones que explican el origen de la desigualdad entre hombres y mujeres y de cómo la diferencia biológica ha incidido en la división del trabajo según el sexo y en las funciones y roles que debe desempeñar cada uno. A continuación señala los principales factores de riesgo que condicionan la violencia machista en las primeras relaciones am...

  13. RESPOSTA DO ABACAXIZEIRO À ADIÇÃO DE NITROGÊNIO, POTÁSSIO E CALCÁRIO EM LATOSSOLO AMARELO DO NORDESTE PARAENSE

    Directory of Open Access Journals (Sweden)

    VELOSO CARLOS ALBERTO COSTA

    2001-01-01

    Full Text Available O presente trabalho foi desenvolvido no período compreendido entre abril de 1997 e novembro de 1998, com o objetivo de avaliar o efeito da aplicação do nitrogênio e do potássio em diferentes níveis de calagem sobre a produtividade e qualidade do fruto do abacaxizeiro, num Latossolo Amarelo distrófico (Oxisol, no município de Capitão Poço, localizado na mesorregião do nordeste paraense. Os tratamentos constaram de quatro doses de nitrogênio (0; 6; 12 e 18 g/planta de N na forma de uréia; quatro doses de potássio (0; 9; 18 e 27 g/planta de K2O na forma de cloreto de potássio e duas doses de calcário dolomítico (0 e 1 t/ha. Utilizou-se o delineamento em blocos ao acaso, com três repetições, sendo os tratamentos dispostos em esquema de parcelas subdivididas, 4 x 4 x 2, correspondendo a quatro doses de nitrogênio, quatro doses de potássio e duas doses de calcário. Na parcela, ficaram as doses de calcário e, na subparcela, as combinações das doses de nitrogênio e potássio. Cada subparcela foi composta de 60 plantas, com 32 plantas úteis da cultivar "Pérola", espaçadas 90 cm entre fileiras duplas, 40cm entre as filas simples e 30cm entre plantas. A calagem não aumentou a produção e o teor de K nas folhas. Além disso, diminuiu o tamanho dos frutos. A adubação nitrogenada não teve efeito na produção e peso do fruto com coroa; na presença das doses de potássio, elevou o rendimento de suco do abacaxi. A adição de potássio, na forma de cloreto de potássio, aumentou a produção com a dose de 22 g/planta de K2O, sendo que foi obtida a produção máxima de 79 t/ha de frutos com coroa. O diâmetro e comprimento do fruto aumentaram com as doses de potássio, e a acidez do fruto decresceu linearmente. Os teores de Ca, Mg, N e K nas folhas aumentaram com a aplicação de calcário e de adubos nitrogenados e potássicos.

  14. CALDoseX: a software tool for absorbed dose calculations in diagnostic radiology

    International Nuclear Information System (INIS)

    Kramer, R.; Khourya, H.J.; Vieira, J.W.

    2008-01-01

    Conversion coefficients (CCs) between absorbed dose to organs and tissues at risk and measurable quantities commonly used in X-ray diagnosis have been calculated for the last 30 years mostly with mathematical MIRD5-type phantoms, in which organs are represented by simple geometrical bodies, like ellipsoids, tori, truncated cylinders, etc. In contrast, voxel-based phantoms are true to nature representations of human bodies. The purpose of this study is therefore to calculate CCs for common examinations in X-ray diagnosis with the recently developed MAX06 (Male Adult voXel) and FAX06 (Female Adult voXel) phantoms for various projections and different X-ray spectra and to make these CCs available to the public through a software tool, called CALDose X (CALculation of Dose for X-ray diagnosis). (author)

  15. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  16. Changes in tumor cell response due to prolonged dose delivery times in fractionated radiation therapy

    International Nuclear Information System (INIS)

    Paganetti, Harald

    2005-01-01

    Purpose: Dynamic radiation therapy, such as intensity-modulated radiation therapy, delivers more complex treatment fields than conventional techniques. The increased complexity causes longer dose delivery times for each fraction. The cellular damage after a full treatment may depend on the dose rate, because sublethal radiation damage can be repaired more efficiently during prolonged dose delivery. The goal of this study was to investigate the significance of this effect in fractionated radiation therapy. Methods and Materials: The lethal/potentially lethal model was used to calculate lesion induction rates for repairable and nonrepairable lesions. Dose rate effects were analyzed for 9 different cell lines (8 human tumor xenografts and a C3H10T1/2 cell line). The effects of single-fraction as well as fractionated irradiation for different dose rates were studied. Results: Significant differences can be seen for dose rates lower than about 0.1 Gy/min for all cell lines considered. For 60 Gy delivered in 30 fractions, the equivalent dose is reduced by between 1.3% and 12% comparing 2 Gy delivery over 30 min per fraction with 2 Gy delivery over 1 min per fraction. The effect is higher for higher doses per fraction. Furthermore, the results show that dose rate effects do not show a simple correlation with the α/β ratio for ratios between 3 Gy and 31 Gy. Conclusions: If the total dose delivery time for a treatment fraction in radiation therapy increases to about 20 min, a correction for dose rate effects may have to be considered in treatment planning. Adjustments in effective dose may be necessary when comparing intensity-modulated radiation therapy with conventional treatment plans

  17. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    International Nuclear Information System (INIS)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-01-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens

  18. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Science.gov (United States)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  19. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Energy Technology Data Exchange (ETDEWEB)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico); Reynoso-Mejía, Alberto [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F., Mexico and Departamento de Neuroimagen, Instituto Nacional de (Mexico); Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús [Departamento de Neuroimagen, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico)

    2014-11-07

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  20. Entre monos y centauros

    Directory of Open Access Journals (Sweden)

    Serge Gruzinski

    2005-02-01

    Full Text Available    ¿Qué relación puede existir entre Ovidio, Tiziano y unos tlacuilo indios de la sierra otomí ? ¿Qué tienen en comun  el pintor mas famoso del siglo XVI , el veneciano Tiziano (+ 1576,  un poeta latino del primer siglo despues de Cristo, Publio Ovidio Nasón (-43/17 ,  y unos artistas indígenas anónimos del pueblo otomi de Ixmiquilpan?   Aunque la reunión de estos tres nombres parezca extraña y sorprendente, los hilos que los unen no son nada anecdóticos.  Permiten entender mejor la manera...

  1. Relationship between radiation dose estimation in patients submitted to abdominal tomography examination and the body mass index; Relacao entre a estimativa de dose de radiacao em pacientes submetidos a exame de tomografia computadorizada do abdomen e o indice de massa corporal

    Energy Technology Data Exchange (ETDEWEB)

    Capaverde, Alexandre da S.; Pimentel, Juliana; Froner, Ana Paula P., E-mail: alexandre.capaverde@acad.pucrs.br, E-mail: juliana.pimentel@pucrs.br, E-mail: ana.froner@pucrs.br [Hospital Sao Lucas (HSL/PUCRS), Porto Alegre, RS (Brazil); Silva, Ana Maria Marques da, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil). Fac. de Fisica

    2014-07-01

    Because of the radiation dose in computed tomography (CT) is relatively high, it is important to have an estimate of the dose to which the patient is submitted, considering parameters and correction factors, so that the value is closer to the real. The objective of this study is to relate the estimated dose in patients undergoing abdominal CT with BMI (Body Mass Index) groups, considering the specific size of the anatomical region. The work developed in a hospital in Porto Alegre, Brazil, using 16 Siemens Somatom Emotion equipment. We selected 30 adult that underwent to CT of the abdomen in January 2014. Of these, 13 using dose reduction mechanism (Care Dose), (Sample 1) and the rest without this mechanism (Sample 2). Registered weight, height, CTDI{sub vol} (Computed Tomography Dose Index) and anteroposterior and lateral diameter at the umbilicus. BMI and the correction factor for the dose estimates were calculated, according to the specific size of the abdomen. It was determined the percentage change between the CTDI{sub vol} values provided by CT and the value of CTDI{sub vol} after application of the correction factor, plus the average percentage change for each BMI group. The mean percentage change was between 54% and 19% for sample 1 and between 35% and 10% for sample 2, the lowest to highest BMI group. There was a reduction in the medium average percent with the increasing of the BMI groups in both samples. A larger sample of individuals for verification of results is required.

  2. Determination of electron clinical spectra from percentage depth dose (PDD) curves by classical simulated annealing method

    International Nuclear Information System (INIS)

    Visbal, Jorge H. Wilches; Costa, Alessandro M.

    2016-01-01

    Percentage depth dose of electron beams represents an important item of data in radiation therapy treatment since it describes the dosimetric properties of these. Using an accurate transport theory, or the Monte Carlo method, has been shown obvious differences between the dose distribution of electron beams of a clinical accelerator in a water simulator object and the dose distribution of monoenergetic electrons of nominal energy of the clinical accelerator in water. In radiotherapy, the electron spectra should be considered to improve the accuracy of dose calculation since the shape of PDP curve depends of way how radiation particles deposit their energy in patient/phantom, that is, the spectrum. Exist three principal approaches to obtain electron energy spectra from central PDP: Monte Carlo Method, Direct Measurement and Inverse Reconstruction. In this work it will be presented the Simulated Annealing method as a practical, reliable and simple approach of inverse reconstruction as being an optimal alternative to other options. (author)

  3. Relación entre la lateralidad y los aprendizajes escolares

    Directory of Open Access Journals (Sweden)

    M.ª Carmen Mayolas Pi

    2010-09-01

    Full Text Available Muchos son los autores que relacionan los problemas de aprendizaje de un niño con su lateralidad, achacando a la lateralidad contrariada, cruzada o no definida los problemas en la adquisición, entre otras, de habilidades lecto-escritoras. En el presente trabajo hemos pasado un test de lateralidad a 170 niños de entre 6 y 7 años (primero y segundo de primaria con pruebas de miembro superior, miembro inferior y ojo, así como de discriminación de derecha-izquierda y de orientación espacial. A su vez, los profesores tutores han valorado varios ítems del aprendizaje escolar de los niños, con cuestiones sobre su comprensión lectora, su razonamiento matemático y su atención en clase, entre otras. Según nuestros resultados, los niños con lateralidad homogénea diestra son los que obtienen mejores valoraciones en todos los ítems de aprendizaje con respecto a los homogéneos zurdos, los cruzados y los no confirmados, siendo los pocos casos que tenemos de homogéneos zurdos (un 3% de la muestra los que tienen peores valoraciones. Además, los niños que discriminan entre derecha e izquierda también tienen mejor sus aprendizajes con respecto a los que no lo hacen, así como los que se orientan bien en el espacio con respecto a los que se orientan mal.

  4. Interações medicamentosas potenciais entre medicamentos psicotrópicos dispensados

    Directory of Open Access Journals (Sweden)

    Eloise Balen

    Full Text Available RESUMO Objetivo Estimar a frequência e caracterizar as interações medicamentosas potenciais entre fármacos psicotrópicos sujeitos a controle especial pela portaria 344/98 da Agência Nacional de Vigilância Sanitária (Anvisa, os quais foram prescritos e dispensados em uma farmácia pública do Município de Cascavel, Paraná. Métodos Estudo retrospectivo com desenho seccional foi realizado em uma Farmácia Pública Municipal. A amostra foi composta por prescrições de medicamentos sujeitos a controle especial, dispensados entre primeiro de julho a 31 de agosto de 2010. As prescrições retidas na farmácia foram analisadas retrospectivamente e as informações, coletadas. As interações medicamentosas potenciais foram identificadas em 824 prescrições. Resultados As prescrições eram na maioria para pacientes do sexo feminino e com idade entre 19 e 59 anos. Em relação à especialidade do prescritor, 30,6% foram prescritas por psiquiatra. Em 77,9% das prescrições identificou-se pelo menos uma interação medicamentosa potencial. Foram descritas 54 diferentes interações medicamentosas potenciais, sendo 34 graves e 20 moderadas. Encontrou-se uma correlação linear entre medicamentos prescritos e interações medicamentosas potenciais (p valor < 0,001. Conclusão O presente estudo identificou uma alta frequência de interações medicamentosas potenciais envolvendo fármacos de controle especial e uma associação positiva entre o número de fármacos prescritos com a maior frequência dessas interações.

  5. Sinergias entre Luxemburgo, ACNUR y Skype

    OpenAIRE

    Bertout, Antoine; Bourcy, Marc de; Faisal, Mohammad

    2011-01-01

    Una reciente asociación estratégica entre ACNUR, el Gobierno de Luxemburgo y el proveedor de software para comunicaciones Skype permite al personal de ACNUR en zonas de condiciones de vida difíciles mantenerse en contacto con sus familiares y amigos. Los socios evalúan de qué forma podría adaptarse la tecnología para otras organizaciones humanitarias.

  6. Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor

    International Nuclear Information System (INIS)

    Cheon, Geum Seong; Kim, Chang Uk; Kim, Hoi Nam; Heo, Gyeong Hun; Song, Jin Ho; Hong, Joo Yeong; Jeong, Jae Yong

    2010-01-01

    Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two different modalities. The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head and neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. In case of comparing both simple summation absorbed dose and integration absorbed dose, the

  7. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  8. Continuidade entre estética e investigação na teoria da arte deweyana: a educação entre arte e ciência, valor e método, ou entre o ideal e o real

    OpenAIRE

    Ana Daniele de Godoy Dorsa

    2013-01-01

    A presente pesquisa, de natureza teórico-filosófica, argumenta descritivamente a teoria estética do filósofo americano John Dewey, em função do seu chamado \\"princípio de continuidade\\", próprio do sistema filosófico deweyano como um todo. Nessa empreitada, privilegiou-se o recorte da continuidade entre o estético e o científico, ou entre valor e investigação enquanto característica essencial de tal teoria estética. Na observação dos pressupostos filosóficos gerais do filósofo, verificou-se q...

  9. Las relaciones entre España y Japón

    OpenAIRE

    Jensana, Amadeo

    2013-01-01

    Si bien España y Japón son dos países separados por más de 10.000 kilómetros existe una importante afinidad cultural entre ambos pueblos. Los japoneses admiran muchas de las manifestaciones culturales españolas, entre las que destacan la arquitectura (especialmente el Modernismo catalán), el flamenco, la gastronomía o el deporte (hay numerosos seguidores de la Liga Profesional de Fútbol). Por su parte, los españoles son plenamente conscientes del nivel tecnológico de las grandes corporacio...

  10. The radiological consequences of notional accidental releases of radioactivity from fast breeder reactors: sensitivity to the dose-effect relationships adopted for early biological effects

    International Nuclear Information System (INIS)

    Kelly, G.N.; Simmonds, J.R.; Smith, H.; Stather, J.W.

    1979-07-01

    This study considered the sensitivity to the dose-response relationships adopted for the estimation of early biological effects from notional accidental releases of radioactivity from fast breeder reactors. Two distinct aspects were considered: the sensitivity of the predicted consequences to variation in the dose-mortality relationships for irradiation of the bone marrow and the lung; and the influence of simple supportive medical treatment in reducing the incidence of early deaths in the exposed population. The numbers of early effects estimated in the initial study were relatively insensitive to variation in the dose-mortality relationships within the bounds proposed. The few exceptions concerned releases of particular nuclide composition, and the variation in the predicted consequences could be around an order of magnitude; the absolute numbers of effects however were in general small when the sensitivity was most pronounced. The reduction in the incidence of early deaths when using simple supportive treatment varied markedly with the nuclide composition of the release. Areas of uncertainty were identified where further research and investigation might most profitably be directed with a view to improving the reliability of the dose-effect relationships adopted and hence of the predicted consequences of the release considered. (author)

  11. Dynamically accumulated dose and 4D accumulated dose for moving tumors

    International Nuclear Information System (INIS)

    Li Heng; Li Yupeng; Zhang Xiaodong; Li Xiaoqiang; Liu Wei; Gillin, Michael T.; Zhu, X. Ronald

    2012-01-01

    Purpose: The purpose of this work was to investigate the relationship between dynamically accumulated dose (dynamic dose) and 4D accumulated dose (4D dose) for irradiation of moving tumors, and to quantify the dose uncertainty induced by tumor motion. Methods: The authors established that regardless of treatment modality and delivery properties, the dynamic dose will converge to the 4D dose, instead of the 3D static dose, after multiple deliveries. The bounds of dynamic dose, or the maximum estimation error using 4D or static dose, were established for the 4D and static doses, respectively. Numerical simulations were performed (1) to prove the principle that for each phase, after multiple deliveries, the average number of deliveries for any given time converges to the total number of fractions (K) over the number of phases (N); (2) to investigate the dose difference between the 4D and dynamic doses as a function of the number of deliveries for deliveries of a “pulsed beam”; and (3) to investigate the dose difference between 4D dose and dynamic doses as a function of delivery time for deliveries of a “continuous beam.” A Poisson model was developed to estimate the mean dose error as a function of number of deliveries or delivered time for both pulsed beam and continuous beam. Results: The numerical simulations confirmed that the number of deliveries for each phase converges to K/N, assuming a random starting phase. Simulations for the pulsed beam and continuous beam also suggested that the dose error is a strong function of the number of deliveries and/or total deliver time and could be a function of the breathing cycle, depending on the mode of delivery. The Poisson model agrees well with the simulation. Conclusions: Dynamically accumulated dose will converge to the 4D accumulated dose after multiple deliveries, regardless of treatment modality. Bounds of the dynamic dose could be determined using quantities derived from 4D doses, and the mean dose

  12. Soroprevalência de anticorpos contra vírus herpes simples 1-2 no Brasil Seroprevalencia de anticuerpos contra virus herpes simples 1-2 en Brasil Seroprevalence of herpes simplex 1-2 antibodies in Brazil

    Directory of Open Access Journals (Sweden)

    Sue Ann Costa Clemens

    2010-08-01

    Full Text Available OBJETIVO: Estimar a soroprevalência de anticorpos por vírus herpes simples (HSV-1 e HSV-2 e analisar fatores associados no Brasil. MÉTODOS: Estudo transversal realizado entre 1996 e 1997 em 1.090 indivíduos com idade entre um e 40 anos da população geral, em quatro diferentes regiões geográficas no Brasil. Foram analisadas amostras sangüíneas para detecção de anticorpos para HSV-1 e HSV-2 com teste tipo-específico Elisa. Foram descritas freqüências e proporções, comparadas entre grupos utilizando o teste de Fisher bilateral exato. Foi realizada análise de regressão logística para avaliar influência das variáveis sociodemográficas e histórico de DST, sobre a soroprevalência de HSV-1 e/ou HSV-2. RESULTADOS: As soroprevalências de anticorpos para HSV-1 e HSV-2, ajustadas por idade, foram 67,2% e 11,3% respectivamente, sem diferença quanto ao sexo e maiores na Região Norte. As soroprevalências aumentaram com a idade, e para HSV-2 o maior aumento ocorreu na adolescência e entre adultos jovens. Indivíduos soropositivos para HSV-1 apresentaram maior risco de serem positivos para HSV-2 (15,7% quando comparados com os negativos para HSV-1 (4,7%. Na análise multivariada, o histórico de DST aumentou significativamente (OR=3,2 a probabilidade de soropositividade para HSV-2. CONCLUSÕES: As soroprevalências para HSV-1 e para HSV-2 variam com a idade e entre as regiões do Brasil. História pregressa de DST é importante fator de risco para aquisição de infecção por HSV-2.OBJETIVO: Estimar la seroprevalencia de anticuerpos por virus herpes simples (HSV-1 y HSV-2 en diferentes áreas geográficas en Brasil y analizar factores asociados. MÉTODOS: Estudio transversal realizado entre 1996 y 1997 con individuos de la población en general en cuatro diferentes áreas geográficas en Brasil y estratificados por edad (de uno a 40 años y sexo, de los cuales 1.090 fueron incluidos en el análisis final. Fueron analizadas muestras

  13. ESCREVER ENTRE AS LÍNGUAS: TRADUÇÃO E GÊNERO EM NANCY HUSTON

    OpenAIRE

    WILHELM, Jane Elisabeth; COSTA, Pâmela Berton; DEÂNGELI, Maria Angélica

    2017-01-01

    O entre duas línguas da auto-tradução em Nancy Huston subverte as relações hierárquicas entre o original e a tradução, ou a oposição entre língua materna e língua estrangeira, e nos convida assim a nos interrogarmos sobre nossas práticas e representações de escrita e de tradução. Buscamos compreender em que medida a escrita entre o francês e o inglês de Nancy Huston questiona não somente as categorias tradicionais de tradução, mas também o gênero como construção social. A história da tradução...

  14. A review of radiology staff doses and dose monitoring requirements

    International Nuclear Information System (INIS)

    Martin, C. J.

    2009-01-01

    Studies of radiation doses received during X-ray procedures by radiology, cardiology and other clinical staff have been reviewed. Data for effective dose (E), and doses to the eyes, thyroid, hands and legs have been analysed. These data have been supplemented with local measurements to determine the most exposed part of the hand for monitoring purposes. There are ranges of 60-100 in doses to individual tissues reported in the literature for similar procedures at different centres. While ranges in the doses per unit dose-area product (DAP) are between 10 and 25, large variations in dose result from differences in the sensitivity of the X-ray equipment, the type of procedure and the operator technique, but protection factors are important in maintaining dose levels as low as possible. The influence of shielding devices is significant for determining the dose to the eyes and thyroid, and the position of the operator, which depends on the procedure, is the most significant factor determining doses to the hands. A second body dosemeter worn at the level of the collar is recommended for operators with high workloads for use in assessment of effective dose and the dose to the eye. It is proposed that the third quartile values from the distributions of dose per unit DAP identified in the review might be employed in predicting the orders of magnitude of doses to the eye, thyroid and hands, based on interventional operator workloads. Such dose estimates could be employed in risk assessments when reviewing protection and monitoring requirements. A dosemeter worn on the little finger of the hand nearest to the X-ray tube is recommended for monitoring the hand. (authors)

  15. Asymmetric fan beams (AFB) for improvement of the craniocaudal dose distribution in helical tomotherapy delivery

    International Nuclear Information System (INIS)

    Gladwish, Adam; Kron, Tomas; McNiven, Andrea; Bauman, Glenn; Van Dyk, Jake

    2004-01-01

    Helical tomotherapy (HT) is a novel radiotherapy technique that utilizes intensity modulated fan beams that deliver highly conformal dose distributions in a helical beam trajectory. The most significant limitation in dose delivery with a constant fan beam thickness (FBT) is the penumbra width of the dose distribution in the craniocaudal direction, which is equivalent to the FBT. We propose to employ a half-blocked fan beam at start and stop location to reduce the penumbra width by half. By opening the jaw slowly during the helical delivery until the desired FBT is achieved it is possible to create a sharper edge in the superior and inferior direction from the target. The technique was studied using a tomotherapy beam model implemented on a commercial treatment planning system (Theraplan Plus V3.0). It was demonstrated that the dose distribution delivered using a 25 mm fan beam can be improved significantly, to reduce the dose to normal structures located superiorly and inferiorly of the target. Dosimetry for this technique is straightforward down to a FBT of 15 mm and implementation should be simple as no changes in couch movement are required compared to a standard HT delivery. We conclude that the use of asymmetric collimated fan beams for the start and stop of the helical tomotherapeutic dose delivery has the potential of significantly improving the dose distribution in helical tomotherapy

  16. Software for the estimation of foetal radiation dose to patients and staff in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Osei, E K [Department of Radiation Physics, Princess Margaret Hospital, 610 University Avenue, Toronto ON M5G 2M9 (Canada); Darko, J B [Department of Radiation Physics, Princess Margaret Hospital, 610 University Avenue, Toronto ON M5G 2M9 (Canada); Faulkner, K [Quality Assurance Centre, Newcastle General Hospital, Westgate Road, Newcastle Upon Tyne NE4 6BE (United Kingdom); Kotre, C J [Regional Medical Physics Department, Newcastle General Hospital, Westgate Road, Newcastle Upon Tyne NE4 6BE (United Kingdom)

    2003-06-01

    Occasionally, it is clinically necessary to perform a radiological examination(s) on a woman who is known to be pregnant or an examination is performed on a woman who subsequently discovers that she was pregnant at the time. In radiological examinations, especially of the lower abdomen and pelvis area, the foetus is directly irradiated. It is therefore important to be able to determine the absorbed dose to the foetus in diagnostic radiology for pregnant patients as well as the foetal dose from occupational exposure of the pregnant worker. The determination of the absorbed dose to the unborn child in diagnostic radiology is of interest as a basis for risk estimates from medical exposure of the pregnant patient and occupational exposure of the pregnant worker. In this paper we describe a simple computer program, FetDose, which calculates the dose to the foetus from both medical and occupational exposures of the pregnant woman. It also calculates the risks of in utero exposure, compares calculated doses with published data in the literature and provides information on the natural spontaneous risks. The program will be a useful tool for the medical and paramedical personnel who are involved with foetal dose (and hence risks) calculations and counselling of pregnant women who may be concerned about in utero exposure of their foetuses.

  17. Software for the estimation of foetal radiation dose to patients and staff in diagnostic radiology

    International Nuclear Information System (INIS)

    Osei, E K; Darko, J B; Faulkner, K; Kotre, C J

    2003-01-01

    Occasionally, it is clinically necessary to perform a radiological examination(s) on a woman who is known to be pregnant or an examination is performed on a woman who subsequently discovers that she was pregnant at the time. In radiological examinations, especially of the lower abdomen and pelvis area, the foetus is directly irradiated. It is therefore important to be able to determine the absorbed dose to the foetus in diagnostic radiology for pregnant patients as well as the foetal dose from occupational exposure of the pregnant worker. The determination of the absorbed dose to the unborn child in diagnostic radiology is of interest as a basis for risk estimates from medical exposure of the pregnant patient and occupational exposure of the pregnant worker. In this paper we describe a simple computer program, FetDose, which calculates the dose to the foetus from both medical and occupational exposures of the pregnant woman. It also calculates the risks of in utero exposure, compares calculated doses with published data in the literature and provides information on the natural spontaneous risks. The program will be a useful tool for the medical and paramedical personnel who are involved with foetal dose (and hence risks) calculations and counselling of pregnant women who may be concerned about in utero exposure of their foetuses

  18. Entre-sons, entre-mundos, entre-idades: ações dialógicas, cultura adolescente e educação musical

    OpenAIRE

    Vertamatti, Leila Rosa Gonçalves [UNESP

    2012-01-01

    O presente trabalho tem como ponto central a reflexão a respeito da prática da Educação Musical de jovens entre 11 e 14 anos, do Colégio São José de São Bernardo do Campo, a partir de uma proposta que dialogue com o universo do adolescente, a invenção, a percepção do ambiente acústico, visual, social e cultural e o contexto escolar. A principal questão da investigação é a discussão de processos de elaboração de ações musicais com base em um conceito de prática que leve em conta a distância ex...

  19. GROWTH AND LEVELS OF N, P AND K IN ROOTSTOCKS OF TAMARIND TREES USING ORGANIC SUBSTRATES AND DOSES OF PHOSPHORUS

    Directory of Open Access Journals (Sweden)

    EDUARDO CASTRO PEREIRA

    2016-01-01

    Full Text Available The aim of this study was to evaluate different organic substrates and phosphorus doses on the growth and leaf content of nitrogen, phosphorus and potassium in rootstocks of Tamarindus indica L. The experiment was performed in a greenhouse nursery located on the campus of the Universidade Federal Rural do Semi-Árido (UFERSA, from March to October 2013. The treatments consisted of three organic sources at a concentration of 40% (v/v (bovine manure, goat manure and a commercial organic compound and four doses of simple superphosphate (0, 0 kg m-3, 2.5 kg m-3, 5.0 kg m-3 and 7.5 kg m-3. The experiment was conducted in a randomized block design (RBD, with 12 treatments (substrates, four replications and 10 plants per plot, totaling 480 plants. The goat manure and the organic compound were the most suitable treatments for the production of rootstocks of the tamarind tree. The maximum dose of 7.5 g kg-1 of simple superphosphate caused the highest levels of phosphorus and potassium in the dry mass of shoots. The nutrients in the dry matter of shoots accumulated in the following order: N > K > P.

  20. Using a thermoluminescent dosimeter to evaluate the location reliability of the highest–skin dose area detected by treatment planning in radiotherapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Li-Min, E-mail: limin.sun@yahoo.com [Department of Radiation Oncology, Zuoying Branch of Kaohsiung Armed Forces General Hospital, Kaohsiung City, Taiwan (China); Huang, Chih-Jen [Department of Radiation Oncology, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan (China); Faculty of Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan (China); College of Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan (China); Chen, Hsiao-Yun [Department of Radiation Oncology, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan (China); Meng, Fan-Yun [Department of General Surgery, Zuoying Branch of Kaohsiung Armed Forces General Hospital, Kaohsiung City, Taiwan (China); Lu, Tsung-Hsien [Department of Radiation Oncology, Zuoying Branch of Kaohsiung Armed Forces General Hospital, Kaohsiung City, Taiwan (China); Tsao, Min-Jen [Department of General Surgery, Zuoying Branch of Kaohsiung Armed Forces General Hospital, Kaohsiung City, Taiwan (China)

    2014-01-01

    Acute skin reaction during adjuvant radiotherapy for breast cancer is an inevitable process, and its severity is related to the skin dose. A high–skin dose area can be speculated based on the isodose distribution shown on a treatment planning. To determine whether treatment planning can reflect high–skin dose location, 80 patients were collected and their skin doses in different areas were measured using a thermoluminescent dosimeter to locate the highest–skin dose area in each patient. We determined whether the skin dose is consistent with the highest-dose area estimated by the treatment planning of the same patient. The χ{sup 2} and Fisher exact tests revealed that these 2 methods yielded more consistent results when the highest-dose spots were located in the axillary and breast areas but not in the inframammary area. We suggest that skin doses shown on the treatment planning might be a reliable and simple alternative method for estimating the highest skin doses in some areas.

  1. Using a thermoluminescent dosimeter to evaluate the location reliability of the highest–skin dose area detected by treatment planning in radiotherapy for breast cancer

    International Nuclear Information System (INIS)

    Sun, Li-Min; Huang, Chih-Jen; Chen, Hsiao-Yun; Meng, Fan-Yun; Lu, Tsung-Hsien; Tsao, Min-Jen

    2014-01-01

    Acute skin reaction during adjuvant radiotherapy for breast cancer is an inevitable process, and its severity is related to the skin dose. A high–skin dose area can be speculated based on the isodose distribution shown on a treatment planning. To determine whether treatment planning can reflect high–skin dose location, 80 patients were collected and their skin doses in different areas were measured using a thermoluminescent dosimeter to locate the highest–skin dose area in each patient. We determined whether the skin dose is consistent with the highest-dose area estimated by the treatment planning of the same patient. The χ 2 and Fisher exact tests revealed that these 2 methods yielded more consistent results when the highest-dose spots were located in the axillary and breast areas but not in the inframammary area. We suggest that skin doses shown on the treatment planning might be a reliable and simple alternative method for estimating the highest skin doses in some areas

  2. Evaluation of concave dose distributions created using an inverse planning system

    International Nuclear Information System (INIS)

    Hunt, Margie A.; Hsiung, C.-Y.; Spirou, Spirodon V.; Chui, C.-S.; Amols, Howard I.; Ling, Clifton C.

    2002-01-01

    acceptable PTV uniformity index is achieved is discussed. This strategy can be used, in simple patient geometries, to ensure the lowest possible normal tissue dose. Strategies for setting the optimum dose constraints and penalties may vary for different optimization algorithms and objective functions. Increasing the number of beams can significantly improve normal tissue dose and target uniformity in situations where the PTV-NT separation is small or the normal tissue dose limits are severe. Setting unrealistically severe constraints in such situations often results in dose distributions that are inferior to plans achieved with more lenient constraints

  3. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  4. Responsabilidad extracontractual y contractual: barrera entre ambas

    Directory of Open Access Journals (Sweden)

    González Hernández, Rut

    2013-01-01

    Full Text Available La finalidad que persigue el sistema de responsabilidad civiles el resarcimiento del daño causado con independencia de que proceda la responsabilidad contractual o la extracontractual, coexistiendo ambas en nuestro ordenamiento jurídico y resultando en ocasiones complicado discernir la frontera entre una y otra.

  5. Universal field matching in craniospinal irradiation by a background-dose gradient-optimized method.

    Science.gov (United States)

    Traneus, Erik; Bizzocchi, Nicola; Fellin, Francesco; Rombi, Barbara; Farace, Paolo

    2018-01-01

    The gradient-optimized methods are overcoming the traditional feathering methods to plan field junctions in craniospinal irradiation. In this note, a new gradient-optimized technique, based on the use of a background dose, is described. Treatment planning was performed by RayStation (RaySearch Laboratories, Stockholm, Sweden) on the CT scans of a pediatric patient. Both proton (by pencil beam scanning) and photon (by volumetric modulated arc therapy) treatments were planned with three isocenters. An 'in silico' ideal background dose was created first to cover the upper-spinal target and to produce a perfect dose gradient along the upper and lower junction regions. Using it as background, the cranial and the lower-spinal beams were planned by inverse optimization to obtain dose coverage of their relevant targets and of the junction volumes. Finally, the upper-spinal beam was inversely planned after removal of the background dose and with the previously optimized beams switched on. In both proton and photon plans, the optimized cranial and the lower-spinal beams produced a perfect linear gradient in the junction regions, complementary to that produced by the optimized upper-spinal beam. The final dose distributions showed a homogeneous coverage of the targets. Our simple technique allowed to obtain high-quality gradients in the junction region. Such technique universally works for photons as well as protons and could be applicable to the TPSs that allow to manage a background dose. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  6. Mass spectrometric analysis of simple hydrogen compounds; Analyse de composes hydrogenes simples au spectrometre de masse

    Energy Technology Data Exchange (ETDEWEB)

    Nief, C; Botter, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    A uranium furnace is inserted in the gas inlet line of a mass spectrometer between the leak and the source. The line is fed with simple hydrogen compounds (H{sub 2}O, NH{sub 3}, H{sub 2}S) which are in this way reduced to hydrogen gas. Memory effects are largely avoided by heating the sample line to 90 deg. C. The speed of the isotopic analysis is only slightly less than that of hydrogen gas itself; the accuracy is better due to the reduction of fractionating effects in the leak. For the absolute measurements of deuterium in water, the presence of H{sub 3}{sup +} is a problem. Water samples, prepared by mixing an unknown light water sample with different amounts of heavy water, are equilibrated with hydrogen sulphide and analysis of the two phases of each sample enables the zero of the concentration scale to be determined from the point of intersection of the two curves obtained by plotting mixture composition against the observed isotope ratio in the two phases. The whole experiment can be carried out in the apparatus described which analyses hydrogen in H{sub 2}S and H{sub 2}O in the same way. (author) [French] Un four a uranium est insere dans la ligne d'introduction de gaz d'un spectrometre de masse entre la fuite et la source. La ligne est alimentee par des composes hydrogenes simples (H{sub 2}O, NH{sub 3}, H{sub 2}S) qui sont de cette facon transformes en hydrogene gazeux. On evite dans une large mesure les effets de memoire en chauffant la ligne de l'echantillon jusqu'a 90 deg. C. La vitesse de l'analyse isotopique est seulement legerement inferieure a celle de l'hydrogene gazeux lui-meme; la precision est meilleure du fait de la reduction des effets de fractionnement dans la fuite. Pour les mesures absolues du deuterium dans l'eau, la presence de H{sub 3}{sup +} pose un probleme. Les echantillons d'eau, prepares en melangeant un echantillon inconnu d'eau legere a differentes quantites d'eau lourde, sont equilibres par de l'hydrogene sulfure et l'analyse de

  7. A simple planning technique of craniospinal irradiation in the eclipse treatment planning system

    Directory of Open Access Journals (Sweden)

    Hemalatha Athiyaman

    2014-01-01

    Full Text Available A new planning method for Craniospinal Irradiation by Eclipse treatment planning system using Field alignment, Field-in-Field technique was developed. Advantage of this planning method was also studied retrospectively for previously treated five patients of medulloblastoma with variable spine length. Plan consists of half beam blocked parallel opposed cranium, and a single posterior cervicospine field was created by sharing the same isocenter, which obviates divergence matching. Further, a single symmetrical field was created to treat remaining Lumbosacral spine. Matching between a inferior diverging edge of cervicospine field and superior diverging edge of a Lumbosacral field was done using the field alignment option. ′Field alignment′ is specific option in the Eclipse Treatment Planning System, which automatically matches the field edge divergence as per field alignment rule. Multiple segments were applied in both the spine field to manage with hot and cold spots created by varying depth of spinal cord. Plan becomes fully computerized using this field alignment option and multiple segments. Plan evaluation and calculated mean modified Homogeneity Index (1.04 and 0.1 ensured that dose to target volume is homogeneous and critical organ doses were within tolerance. Dose variation at the spinal field junction was verified using ionization chamber array (I′MatriXX for matched, overlapped and gap junction spine fields; the delivered dose distribution confirmed the ideal clinical match, over exposure and under exposure at the junction, respectively. This method is simple to plan, executable in Record and Verify mode and can be adopted for various length of spinal cord with only two isocenter in shorter treatment time.

  8. Droids Made Simple

    CERN Document Server

    Mazo, Gary

    2011-01-01

    If you have a Droid series smartphone - Droid, Droid X, Droid 2, or Droid 2 Global - and are eager to get the most out of your device, Droids Made Simple is perfect for you. Authors Martin Trautschold, Gary Mazo and Marziah Karch guide you through all of the features, tips, and tricks using their proven combination of clear instructions and detailed visuals. With hundreds of annotated screenshots and step-by-step directions, Droids Made Simple will transform you into a Droid expert, improving your productivity, and most importantly, helping you take advantage of all of the cool features that c

  9. Association "Les Simples"

    OpenAIRE

    Thouzery, Michel

    2014-01-01

    Fondée par les producteurs du Syndicat Inter-Massifs pour la Production et l’Économie des Simples (S.I.M.P.L.E.S), l’association base son action sur la recherche et le maintien d’une production de qualité (herboristerie et préparations à base de plantes) qui prend en compte le respect de l’environnement et la pérennité des petits producteurs en zone de montagne. Actions de formation Stages de découverte de la flore médicinale sauvage, Stages de culture et transformation des plantes médicinale...

  10. Quantitative analysis of biological responses to low dose-rate γ-radiation, including dose, irradiation time, and dose-rate

    International Nuclear Information System (INIS)

    Magae, J.; Furukawa, C.; Kawakami, Y.; Hoshi, Y.; Ogata, H.

    2003-01-01

    Full text: Because biological responses to radiation are complex processes dependent on irradiation time as well as total dose, it is necessary to include dose, dose-rate and irradiation time simultaneously to predict the risk of low dose-rate irradiation. In this study, we analyzed quantitative relationship among dose, irradiation time and dose-rate, using chromosomal breakage and proliferation inhibition of human cells. For evaluation of chromosome breakage we assessed micronuclei induced by radiation. U2OS cells, a human osteosarcoma cell line, were exposed to gamma-ray in irradiation room bearing 50,000 Ci 60 Co. After the irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, cytoplasm and nucleus were stained with DAPI and propidium iodide, and the number of binuclear cells bearing micronuclei was determined by fluorescent microscopy. For proliferation inhibition, cells were cultured for 48 h after the irradiation and [3H] thymidine was pulsed for 4 h before harvesting. Dose-rate in the irradiation room was measured with photoluminescence dosimeter. While irradiation time less than 24 h did not affect dose-response curves for both biological responses, they were remarkably attenuated as exposure time increased to more than 7 days. These biological responses were dependent on dose-rate rather than dose when cells were irradiated for 30 days. Moreover, percentage of micronucleus-forming cells cultured continuously for more than 60 days at the constant dose-rate, was gradually decreased in spite of the total dose accumulation. These results suggest that biological responses at low dose-rate, are remarkably affected by exposure time, that they are dependent on dose-rate rather than total dose in the case of long-term irradiation, and that cells are getting resistant to radiation after the continuous irradiation for 2 months. It is necessary to include effect of irradiation time and dose-rate sufficiently to evaluate risk

  11. Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams

    International Nuclear Information System (INIS)

    Pedroni, E; Scheib, S; Boehringer, T; Coray, A; Grossmann, M; Lin, S; Lomax, A

    2005-01-01

    In this paper we present the pencil beam dose model used for treatment planning at the PSI proton gantry, the only system presently applying proton therapy with a beam scanning technique. The scope of the paper is to give a general overview on the various components of the dose model, on the related measurements and on the practical parametrization of the results. The physical model estimates from first physical principles absolute dose normalized to the number of incident protons. The proton beam flux is measured in practice by plane-parallel ionization chambers (ICs) normalized to protons via Faraday-cup measurements. It is therefore possible to predict and deliver absolute dose directly from this model without other means. The dose predicted in this way agrees very well with the results obtained with ICs calibrated in a cobalt beam. Emphasis is given in this paper to the characterization of nuclear interaction effects, which play a significant role in the model and are the major source of uncertainty in the direct estimation of the absolute dose. Nuclear interactions attenuate the primary proton flux, they modify the shape of the depth-dose curve and produce a faint beam halo of secondary dose around the primary proton pencil beam in water. A very simple beam halo model has been developed and used at PSI to eliminate the systematic dependences of the dose observed as a function of the size of the target volume. We show typical results for the relative (using a CCD system) and absolute (using calibrated ICs) dosimetry, routinely applied for the verification of patient plans. With the dose model including the nuclear beam halo we can predict quite precisely the dose directly from treatment planning without renormalization measurements, independently of the dose, shape and size of the dose fields. This applies also to the complex non-homogeneous dose distributions required for the delivery of range-intensity-modulated proton therapy, a novel therapy technique

  12. Effect of low dose radiation on somatic intrachromosomal recombination in vivo and in vitro

    International Nuclear Information System (INIS)

    Hooker, A.M.; Cormack, J.; Morley, A.A.; Sykes, P.J.; Bhat, M.

    2003-01-01

    Full text: High doses of ionising radiation are mutagenic in a wide range of mutation assays. The majority of radiation exposure studies in in vivo mouse mutation assays have been performed at high doses, eg greater than 1 Gy. However, these doses are not relevant to the low doses of ionising radiation that the majority of the population might likely come into contact with. Radiation protection levels tend to be based on a simple linear no-threshold model which suggests that any radiation above zero is potentially harmful. The pKZ1 recombination mutagenesis mouse model has proven to be a sensitive assay for the detection of mutations caused by low doses of chemical agents. In pKZ1 mice, somatic intrachromosomal recombination (SICR) inversion events can be detected in cells using histochemistry for the E. coli LacZ transgene. We exposed pKZ1 mice to a single radiation dose ranging from 0.001 to 2 Gy. A significant increase in SICR was observed in spleen at the two highest doses of 0.1 and 2 Gy and a significant reduction in SICR below the endogenous frequency was observed at the two lowest doses of 0.01 and 0.001 Gy. After exposing a pKZ1 cell line to the same dose range, a similar J curve response was observed with significant increases in SICR observed at the 3 highest doses and a significant decrease below the endogenous frequency at the lowest dose (0.001 Gy). The next experiments will be to determine the dose where the SICR frequency returns to the endogenous level. The important question posed by these results is 'Is a reduction below the endogenous SICR level caused by low doses of ionising radiation anti-mutagenic?' Studies now need to be performed to investigate the effect of low doses of radiation on other mutation end-points, and the mechanism for the reduction in SICR

  13. Dose rate constant and energy spectrum of interstitial brachytherapy sources

    International Nuclear Information System (INIS)

    Chen Zhe; Nath, Ravinder

    2001-01-01

    In the past two years, several new manufacturers have begun to market low-energy interstitial brachytherapy seeds containing 125 I and 103 Pd. Parallel to this development, the National Institute of Standards and Technology (NIST) has implemented a modification to the air-kerma strength (S K ) standard for 125 I seeds and has also established an S K standard for 103 Pd seeds. These events have generated a considerable number of investigations on the determination of the dose rate constants (Λ) of interstitial brachytherapy seeds. The aim of this work is to study the general properties underlying the determination of Λ and to develop a simple method for a quick and accurate estimation of Λ. As the dose rate constant of clinical seeds is defined at a fixed reference point, we postulated that Λ may be calculated by treating the seed as an effective point source when the seed's source strength is specified in S K and its source characteristics are specified by the photon energy spectrum measured in air at the reference point. Using a semi-analytic approach, an analytic expression for Λ was derived for point sources with known photon energy spectra. This approach enabled a systematic study of Λ as a function of energy. Using the measured energy spectra, the calculated Λ for 125 I model 6711 and 6702 seeds and for 192 Ir seed agreed with the AAPM recommended values within ±1%. For the 103 Pd model 200 seed, the agreement was 5% with a recently measured value (within the ±7% experimental uncertainty) and was within 1% with the Monte Carlo simulations. The analytic expression for Λ proposed here can be evaluated using a programmable calculator or a simple spreadsheet and it provides an efficient method for checking the measured dose rate constant for any interstitial brachytherapy seed once the energy spectrum of the seed is known

  14. Calculation of dose conversion factors for doses in the fingernails to organ doses at external gamma irradiation in air

    International Nuclear Information System (INIS)

    Khailov, A.M.; Ivannikov, A.I.; Skvortsov, V.G.; Stepanenko, V.F.; Orlenko, S.P.; Flood, A.B.; Williams, B.B.; Swartz, H.M.

    2015-01-01

    Absorbed doses to fingernails and organs were calculated for a set of homogenous external gamma-ray irradiation geometries in air. The doses were obtained by stochastic modeling of the ionizing particle transport (Monte Carlo method) for a mathematical human phantom with arms and hands placed loosely along the sides of the body. The resulting dose conversion factors for absorbed doses in fingernails can be used to assess the dose distribution and magnitude in practical dose reconstruction problems. For purposes of estimating dose in a large population exposed to radiation in order to triage people for treatment of acute radiation syndrome, the calculated data for a range of energies having a width of from 0.05 to 3.5 MeV were used to convert absorbed doses in fingernails to corresponding doses in organs and the whole body as well as the effective dose. Doses were assessed based on assumed rates of radioactive fallout at different time periods following a nuclear explosion. - Highlights: • Elemental composition and density of nails were determined. • MIRD-type mathematical human phantom with arms and hands was created. • Organ doses and doses to nails were calculated for external photon exposure in air. • Effective dose and nail doses values are close for rotational and soil surface exposures.

  15. A simple method for measuring glucose utilization of insulin-sensitive tissues by using the brain as a reference

    International Nuclear Information System (INIS)

    Namba, Hiroki; Nakagawa, Keiichi; Iyo, Masaomi; Fukushi, Kiyoshi; Irie, Toshiaki

    1994-01-01

    A simple method, without measurement of the plasma input function, to obtain semiquantitative values of glucose utilization in tissues other than the brain with radioactive deoxyglucose is reported. The brain, in which glucose utilization is essentially insensitive to plasma glucose and insulin concentrations, was used as an internal reference. The effects of graded doses of oral glucose loading (0.5, 1 and 2 mg/g body weight) on insulin-sensitive tissues (heart, muscle and fat tissue) were studied in the rat. By using the brain-reference method, dose-dependent increases in glucose utilization were clearly shown in all the insulin-sensitive tissues examined. The method seems to be of value for measurement of glucose utilization using radioactive deoxyglucose and positron emission tomography in the heart or other insulin-sensitive tissues, especially during glucose loading. (orig.)

  16. Evaluation of dose to skin surface contamination in the factory Juzbado of fuel elements; Evaluacion de dosis a piel por contaminacion superficial en la fabrica de elementos combustibles de Juzbado

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz Trujillo, D.; Agustin Perez Fonseca, A.; Alejandro Fuentes, A.

    2013-07-01

    The aim of this work is previously set a simple calculation methodology applicable to the boundary conditions surrounding the environment where skin contamination may have occurred so that you can evaluate in a simple and fast way the dose that the worker is receiving while enduring such pollution. (Author)

  17. SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

    International Nuclear Information System (INIS)

    Maneru, F; Gracia, M; Gallardo, N; Olasolo, J; Fuentemilla, N; Bragado, L; Martin-Albina, M; Lozares, S; Pellejero, S; Miquelez, S; Rubio, A; Otal, A

    2015-01-01

    Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with 90 Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other

  18. SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

    Energy Technology Data Exchange (ETDEWEB)

    Maneru, F; Gracia, M; Gallardo, N; Olasolo, J; Fuentemilla, N; Bragado, L; Martin-Albina, M; Lozares, S; Pellejero, S; Miquelez, S; Rubio, A [Complejo Hospitalario de Navarra, Pamplona, Navarra (Spain); Otal, A [Hospital Clinica Benidorm, Benidorm, Alicante (Spain)

    2015-06-15

    Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than

  19. Héroes civiles. El teatro entre la cultura erudita y la tradición popular en España

    Directory of Open Access Journals (Sweden)

    Peter Jehle

    2014-06-01

    Full Text Available La reforma intelectual y moral que va implícita con el teatro neoclásico se decide, no en último término, en la capacidad de producción de un nuevo tipo de ciudadano que debe conquistar el escenario para la representación de un nuevo modo de vida. Este ciudadano es un pionero del mundo moderno, un héroe civil, que ya no tiene nada en común con la vieja plantilla del teatro de Lope. Moratín, como Diderot, no crea héroes legendarios, sino que pone en escena a individuos de la sociedad de su tiempo. El Neoclasicismo no consiste en una simple renovación de lo clásico, como parece suponer su nombre, sino en una ruptura respecto de qué mundo imitar y cómo hacerlo. Dicha reforma consiste en una serie de desvinculaciones (entre el escenario y el espacio del público, entre lo trágico y lo cómico, lo sagrado y lo profano, lo socialmente alto y bajo, en las que se concretiza la transformación del teatro en una “escuela de virtudes”. Precisamente para devenir elemento de moralización para producir un sujeto ciudadano, un héroe civil, el teatro requiere la autonomía del arte, en cuyo asilo cobra la fuerza para resistir a las persecuciones de la Iglesia.

  20. Late morbidity profiles in prostate cancer patients treated to 79-84 Gy by a simple four-field coplanar beam arrangement

    International Nuclear Information System (INIS)

    Chism, Derek B.; Horwitz, Eric M.; Hanlon, Alexandra L.; Pinover, Wayne H.; Mitra, Raj K.; Hanks, Gerald E.

    2003-01-01

    Purpose: To describe the frequency and magnitude of late GI and GU morbidity in prostate cancer patients treated to high dose levels with a simple three-dimensional conformal technique. Methods and Materials: A total of 156 intermediate- and high-risk patients were treated between January 1, 1992 and February 28, 1999 with a simple four-field three-dimensional conformal technique to 79-84 Gy. All patients were treated with a four-field conformal technique; the prostate received 82 Gy and the seminal vesicles and periprostatic tissue 46 Gy. GI and GU toxicity was scored according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Morbidity Grading Scale and compared using Kaplan-Meier estimates. Results: The late Grade 2 GI complication rate was 9% and 38% at 3 years for patients treated with and without rectal blocking, respectively (p=0.0004). No Grade 3 late GI complications developed. The rate of Grade 2 late GU complications was 5%, 8%, and 12% at 12, 24, and 36 months, respectively. The Grade 3 late GU complication rate was 2% at 36 months. These differences were not statistically significant. Conclusion: The treatment method described is a simple four-field conformal technique that can be easily implemented in the general radiation community. A dose of 79-84 Gy can be safely delivered to the prostate, with a 9% rate of late Grade 2 GI, 12% rate of late Grade 2 GU, and 2% rate of late Grade 3 GU complications