Sample records for entrance doses seds

  1. Entrance and peripheral dose measurements during radiotherapy

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.

    2008-01-01

    In vivo dosimetry of entrance dose was performed using thermoluminescent dosimeters (TLD) in order to evaluate the clinical application of the build up caps in patient dose measurements and for different treatment techniques. Peripheral dose (thyroid and skin) was measured for patients during breast radiotherapy to evaluate the probability of secondary cancer induction. TLD-100 chips were used with different Copper build up caps (for 6 MV and 15 MV photon beams from two linear accelerators. Entrance doses were measured for patients during radiotherapy course for breast, head and neck, abdomen and pelvis malignancies. The measured entrance dose for the different patients for 6 MV beams is found to be within the ±2.6% compared to the dose derived from theoretical estimation (normalized dose at D max ). The same measurements for 15 MV beams are found to be ±3 %. The perturbation value can reach up to 20% of the D max , which acts as a limitation for entrance dose measurements. An average thyroid skin dose of 3.7% of the prescribed dose was measured per treatment session while the mean skin dose breast treatment session is estimated to be 42% of D max , for both internal and external fields. These results are comparable in those of the in vivo of reported in literature. The risk of fatality due to thyroid cancer per treatment course is 3x10 -3

  2. patient entrance skin doses at minna and ibadan for common

    African Journals Online (AJOL)

    DR. AMINU

    Entrance surface dose from two diagnostic x-ray centers in Nigeria for three common radiological examinations is .... typical ESD values for adult patients for three different ... TTX located in the region of Nigeria where regulatory activities have ...

  3. Determination of Entrance Skin Doses and Organ Doses for Medical X Ray Examinations

    International Nuclear Information System (INIS)

    Tung, C.J.; Cheng, C.Y.; Chao, T.C.; Tsai, H.Y.

    1999-01-01

    A national survey of patient doses for diagnostic X ray radiographs is planned in Taiwan. Entrance skin doses and organ doses for all installed X ray machines will be investigated. A pilot study has been carried out for the national survey to develop a protocol for the dose assessment. Entrance skin doses and organ doses were measured by thermoluminescence dosemeters and calculated by Monte Carlo simulations for several X ray examinations. The conversion factor from free air entrance absorbed dose to entrance skin dose was derived. A formula for the computation of entrance skin doses from inputs of kV p , mA.s, source to skin distance, aluminium filtration, and generator rectifying was constructed. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom. All data will be passed to the Atomic Energy Council for developing a programme of national survey and regulatory controls for diagnostic X ray examinations. (author)

  4. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  5. Entrance doses during lateral lumbar spine and antero-posterior abdomen examinations: generator waveform dependence

    International Nuclear Information System (INIS)

    Morrison, G.D.; Underwood, A.C.

    1995-01-01

    In North Trent, UK, an entrance dose survey of lateral lumbar spine and antero-posterior (AP) abdomen examinations has been carried out in 17 radiology departments. The survey comprised 294 lateral lumbar spine and 322 AP abdomen entrance dose measurements. The mean entrance doses were found to be approximately half of the relevant national reference entrance dose levels of 30 mGy and 10 mGy, respectively. The effect of generator waveform on entrance dose was studied by separating the generators into two types: ''pulsating potential'' (PP) generators and ''constant potential'' (CP) generators for each examination. PP generators comprised 23% of the total number of examinations. The mean entrance dose and radiographic exposure factors from CP generators were found to be significantly lower than those from PP generators. The use of CP type generators, together with low attenuation components can significantly reduce patient entrance doses for these examinations. (author)

  6. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  7. Response studies of three different dosimeters for skin entrance dose measurements using diagnostic X-ray machines

    International Nuclear Information System (INIS)

    Sonawane, A.U.; Kulkarni, Arti; Shirva, V.K.; Butani, M.L.; Pradhan, A.S.

    2008-01-01

    A TLD method based on CaSO 4 :Dy Teflon discs developed at the Bhabha Atomic Research Centre, Mumbai has been extensively used for various applications in diagnostic radiology in India. This method was recently used for evaluation of radiation quality and measurement of skin entrance doses (SEDs) in various hospitals for different diagnostic examinations. The use of TLD discs for these applications involves the process of preparation of TLD discs with different combination of filters and then measurement of TL output under different combinations of filters. The measurement of SEDs in diagnostic radiology is also carried out instantaneously and accurately by using very user friendly and compact state-of-art instruments. These consist of kVp Test-O-Meter (ToM) (Model RADIFLU-9001) and the dose ToM (Model 6001) manufactured by M/s UNFORS, Sweden. The kVp meter automatically calculates kVp and updates it every second in the range from 55 to 145 kVp with the resolution of 0.1 kV. The dose ToM incorporates sealed silicon detector having lead shield under and around, which prevents backscattered radiation from influencing the measurement. The dose Test-O-Meter has excellent energy independence in the range from 50 to 150 kVp and inaccuracy not exceeding 5 % at 70 k Vp. The dose meter is capable of measuring doses up to 9999 μGy

  8. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  9. Entrance surface dose in cerebral interventional radiology procedures

    International Nuclear Information System (INIS)

    Barrera-Rico, M.; López-Rendón, X.; Rivera-Ordóñez, C. E.; Gamboa-deBuen, I.

    2012-01-01

    At the Instituto Nacional de Neurología y Neurocirugía (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 ×1 cm 2 of Gafchromic XR-QA2 film bound in a holder of 15×15 cm 2 in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  10. Entrance surface dose in cerebral interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Barrera-Rico, M.; Lopez-Rendon, X.; Rivera-Ordonez, C. E.; Gamboa-deBuen, I. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico); Instituto Nacional de Neurologia y Neurocirugia Manuel Velasco Suarez, 14269 DF (Mexico); Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico)

    2012-10-23

    At the Instituto Nacional de Neurologia y Neurocirugia (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 Multiplication-Sign 1 cm{sup 2} of Gafchromic XR-QA2 film bound in a holder of 15 Multiplication-Sign 15 cm{sup 2} in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  11. Entrance surface dose measurements in pediatric radiological examinations

    International Nuclear Information System (INIS)

    Ribeiro, L.A.; Yoshimura, E.M.

    2008-01-01

    A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo, in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0.068 mGy (5-9 years old); 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100 mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20 mGy, respectively) are above the European reference levels (1.5 mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a

  12. Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part 1: Assessment of Entrance Doses

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Kemerink, G.J.; Engelshoven, J.M.A. van

    1999-01-01

    The purpose of this study was to obtain representative quantitative information on exposure conditions and entrance doses of occupationally exposed persons (workers) in diagnostic and interventional arteriography. In a study in three hospitals all parameters of the X ray systems that are related to the exposure of workers were quantified with an automatic data acquisition system. Using LiF thermoluminescence dosemeters, entrance doses to workers were measured at the forehead, neck, thorax, abdomen, upper arms, hands and lower legs. Measurements were performed during 353 procedures, and it was found that exposure of workers was predominantly caused by fluoroscopy. Averaged over all procedures in the annual workload, entrance doses were below 120 μGy when an undercouch X ray tube and a mechanical contrast injector were used. For an overcouch tube the doses were higher. It is concluded that entrance doses are low, and that legally established annual dose limits are un-likely to be exceeded. (author)

  13. Evaluation of skin entrance dose imparted on pediatric patients by thorax exams

    International Nuclear Information System (INIS)

    Oliveira, Mercia L.; Khoury, Helen; Drexler, Guenter; GSF-National Research Center for Environment and Health, Neuherberg; Barros, Edison

    2001-01-01

    In this work the results of a survey of skin entrance dose imparted on pediatric patients are present. Positioning the thermo luminescence dosimeters in contact with the patient's skin, in the center of the incident X-ray beam, collected the skin entrance dose data. The patients were grouped in five age groups: infants, 1,1 to 4 years, 4,1 to 6 years, 6,1 to 10 years and older than 10 years. The results show that the average of skin entrance doses is very higher as compared to the European Community Commission reference levels and to other values found in literature. (author)

  14. Estimate of ovarian dose and entrance skin dose in uterine artery embolization procedures

    International Nuclear Information System (INIS)

    Silva, Marcia C.; Nasser, Felipe; Affonso, Breno B.; Araujo Junior, Raimundo T.; Zlotnik, Eduardo; Messina, Marcos L.; Baracat, Edmund C.

    2010-01-01

    The goal of this study was to estimate the ovarian dose and entrance skin dose (ESD) of patients who underwent uterine artery embolization (UAE) procedure. To achieve this, 49 UAE procedures were accompanied where the parameters of image acquisition were recorded for the calculation of the DEP from the output of the X-ray tube. The estimation of the ovarian dose was carried out by the insertion of a vaginal probe containing 3 TLD's. The obtained values were compared with the results of other authors and a higher value of ovarian dose (28,97 cGy) and ESD (403,57 cGy) was found in this work. Analysis of the results allowed to observe that this result was obtained mainly as a result of the high number of arteriography series and the frames/second rates employed. Following on from these observations, the protocol of EMUT was altered reducing the frames/seg rate from 2 to 1. Efforts with a view to reducing the number of arteriography series also became part of the next proceedings. (author)

  15. Skin entrance dose for digital and film radiography in Korean dental schools

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eun Sang; Choi, Kun Ho; Kim, Min Gyu; Lim, Hoi Jeong; Yoon, Suk Ja; Kang, Byung Cheol [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    2005-12-15

    This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician at each school to set the exposure parameters and aiming the x-ray tube for the peri apical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter; Unifors instruments, Billdal, Sweden). The median dose was 491.2 {mu}Gy for digital radiography and 1,205.0 {mu}Gy for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Fifty-nine percent skin entrance dose reduction with digital peri apical radiography was achieved over the film radiography in Korean dental schools.

  16. Skin entrance dose for digital and film radiography in Korean dental schools

    International Nuclear Information System (INIS)

    Cho, Eun Sang; Choi, Kun Ho; Kim, Min Gyu; Lim, Hoi Jeong; Yoon, Suk Ja; Kang, Byung Cheol

    2005-01-01

    This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician at each school to set the exposure parameters and aiming the x-ray tube for the peri apical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter; Unifors instruments, Billdal, Sweden). The median dose was 491.2 μGy for digital radiography and 1,205.0 μGy for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Fifty-nine percent skin entrance dose reduction with digital peri apical radiography was achieved over the film radiography in Korean dental schools.

  17. Changing Default Fluoroscopy Equipment Settings Decreases Entrance Skin Dose in Patients.

    Science.gov (United States)

    Canales, Benjamin K; Sinclair, Lindsay; Kang, Diana; Mench, Anna M; Arreola, Manuel; Bird, Vincent G

    2016-04-01

    Proper fluoroscopic education and protocols may reduce the patient radiation dose but few prospective studies in urology have been performed. Using optically stimulated luminescent dosimeters we tested whether fluoroscopy time and/or entrance skin dose would decrease after educational and radiation reduction protocols. At default manufacturer settings fluoroscopy time and entrance skin dose were prospectively measured using optically stimulated luminescent dosimeters in patients undergoing ureteroscopy, retrograde pyelogram/stent or percutaneous nephrolithotomy with access for stone disease. A validated radiation safety competency test was administered to urology faculty and residents before and after web based, hands-on fluoroscopy training. Default fluoroscopy settings were changed from continuous to intermittent pulse rate and from standard to half-dose output. Fluoroscopy time and entrance skin dose were then measured again. The cohorts of 44 pre-protocol and 50 post-protocol patients with stones were similarly matched. The change in mean fluoroscopy time and entrance skin dose from pre-protocol to post-protocol was -0.6 minutes and -11.6 mGy (33%) for percutaneous nephrolithotomy (p = 0.62 and default settings to intermittent pulse rate (12 frames per second) and half-dose lowered the entrance skin dose by 30% across all endourology patients but most significantly during percutaneous nephrolithotomy. To limit patient radiation exposure fluoroscopy default settings should be decreased before all endourology procedures and image equipment manufacturers should consider lowering standard default renal settings. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. The need for national diagnostic reference levels: entrance surface dose measurement in intraoral radiography

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Shareghi, A.; Kavousi, A.; Ghiassi-Nejad, M.; Jafari-Zadeh, M.; Nazeri, F.; Mozdarani, H.

    2004-01-01

    Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection recommendations, the selection of a diagnostic reference level should be specific to a country or region. Critical organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low as reasonably achievable. To assist the development of DRLs for intraoral radiography, a National Radiation Protection Department-sponsored pilot study was carried out. Materials and methods: thermoluminescent dosimetry is widely acknowledged to be the recommended method for measuring entrance surface doses. In this study, entrance surface doses was measured using LiF thermoluminescent dosimeters on the skin (either mandibular or maxillary arcs) of 40 patients. Three thermoluminescent dosimetry chips were placed on the skin of each patient. The doses were averaged for each radiography and mean entrance surface doses of all patients calculated. Results: the mean ±SD entrance surface dose at the center of the beam on the patient's skin in intraoral radiography was 1.173 ±0.606 mGy (ranged from 0.01 o 0.40 m Gy). The mean entrance surface doses for male and female patients were 1.380± 0.823, and 1.004± 0.258 respectively. No statistically significant difference was found between these means. Despite its necessity , in national level , there is no published data on the diagnostic reference levels for intraoral radiography. However, the results obtained in this study are lower than those reported by investigators in other countries. Conclusion: in IR Iran , due to lack of large scale studies, no diagnostic reference levels have been set for X-ray diagnostic procedures. Due to lack of national diagnostic reference levels, it is not possible to clarify whether in intraoral radiographies any dose reduction techniques are needed. We intend to perform similar nationwide studies to set the

  19. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    Directory of Open Access Journals (Sweden)

    Sina S

    2014-12-01

    Full Text Available Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti and GR-200 (LiF: Mg, Cu, P and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100.

  20. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    Science.gov (United States)

    Sina, S; Zeinali, B; Karimipoorfard, M; Lotfalizadeh, F; Sadeghi, M; Zamani, E; Faghihi, R

    2014-01-01

    Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100. PMID:25599058

  1. Application of work load spectra for estimative of the skin entrance dose

    International Nuclear Information System (INIS)

    Pereira, P.A.A.; Furquim, T.A.C.; Costa, P.R.

    2004-01-01

    The present work refers to obtaining data for the determination of workload spectra related to the use of different radiological equipment. The obtained information was stored in a data base developed for this working program. Values of skin entrance dose were obtained bu using the results of the field research (performed in radiological clinics and hospitals of Sao Paulo). (author)

  2. Determination of entrance skin dose from diagnostic X-ray of human ...

    African Journals Online (AJOL)

    patient during x-ray examination in Federal Medical Centre, Keffi in Nasarawa state, Nigeria. Entrance skin doses (ESDs) for a common type of x-ray procedures, namely chest AP/PA (anterior/posterior) were measured. A total of 200 data were collected from patients who were exposed to diagnostic X-ray during their routine ...

  3. Entrance skin dose on patients undergoing X-ray examinations at ...

    African Journals Online (AJOL)

    survey was conducted on the Entrance Skin Dose (ESD) in patients undergoing X-ray examinations [Skull Postero-Anterior (PA), Skull Lateral (LAT), Chest Postero-Anterior (PA), Chest Lateral (LAT), Abdomen Antero-Posterior (AP) and Pelvis Antero-Posterior (AP)] in five hospitals/Xray centres in Yaba, Lagos State, Nigeria ...

  4. Evaluation of six TPS algorithms in computing entrance and exit doses

    Science.gov (United States)

    Metwaly, Mohamed; Glegg, Martin; Baggarley, Shaun P.; Elliott, Alex

    2014-01-01

    Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC). Measurements with ionization chamber (IC) and diode detector in water phantoms were used as a reference. Comparisons were done in terms of central axis point dose, 1D relative profiles, and 2D absolute gamma analysis. Entrance doses computed by all TPS algorithms agreed to within 2% of the measured values. Exit doses computed by XiO Convolution, XiO Superposition, Eclipse AXB, and Monaco MC agreed with the IC measured doses to within 2%‐3%. Meanwhile, Eclipse PBC and Eclipse AAA computed exit doses were higher than the IC measured doses by up to 5.3% and 4.8%, respectively. Both algorithms assume that full backscatter exists even at the exit level, leading to an overestimation of exit doses. Despite good agreements at the central axis for Eclipse AXB and Monaco MC, 1D relative comparisons showed profiles mismatched at depths beyond 11.5 cm. Overall, the 2D absolute gamma (3%/3 mm) pass rates were better for Monaco MC, while Eclipse AXB failed mostly at the outer 20% of the field area. The findings of this study serve as a useful baseline for the implementation of entrance and exit in vivo dosimetry in clinical departments utilizing any of these six common TPS algorithms for reference comparison. PACS numbers: 87.55.‐x, 87.55.D‐, 87.55.N‐, 87.53.Bn PMID:24892349

  5. In-vivo (entrance) dose measurements in external beam radiotherapy with aqueous FBX dosimetry system

    International Nuclear Information System (INIS)

    Semwal, M.K.; Thakur, P.K.; Bansal, A.K.; Vidyasagar, P.B.

    2005-01-01

    FBX aqueous chemical dosimetry system has been found useful in radiotherapy owing to its low dose measuring capability. In the present work, entrance dose measurements in external beam radiotherapy on a telecobalt machine were carried out with the system on 100 patients. Treatments involving simple beam arrangement of open parallel-opposed beams in cranial and pelvic irradiations were selected for this study. In place of a spectrophotometer, a simple and inexpensive colorimeter was used for absorbance measurements. The purpose was to assess the efficacy of the FBX system for in-vivo dose measurements. The results obtained show that the average discrepancy between the measured and expected dose for both categories of patients was 0.2% (standard deviation 3.2%) with a maximum of +1 0.3%. There were 5.5% cases showing more than ± 5% discrepancy. Comparison of the results obtained with published work on entrance dose measurements, with diode detectors, shows that the inexpensive FBX system can be used for in-vivo (entrance) dose measurements for simple beam arrangements in radiotherapy and can thus serve as a useful QA tool. (author)

  6. In vivo dosimetry with thermoluminescent dosimeters in radiotherapy: entrance and exit doses

    International Nuclear Information System (INIS)

    Alves, C.; Lopes, M.C.

    2000-01-01

    In vivo dosimetry, by entrance and exit dose measurements, is a vital part of a radiotherapy quality assurance program. The uncertainty associated with dose delivery is internationally accepted to be within 5% or inferior depending on the tumor pathology. Thermoluminescent dosimetry is one of the dosimetric techniques used to verify the agreement between delivered and prescribed doses. Nevertheless, it requires a very accurate calibration methodology. We have used LiF chips (4.5 mm diameter and 0.8 mm thick) calibrated towards a PTW ionization chamber of 0.3 cc, in three photon energies: Co-60, 4 and 6 MeV. The TLD reader used was a Rialto 688 from NE Technology and the annealing oven the Eurotherm type 815. The calibration methodology relies on the experimental determination of individual correction factors and on a correction factor derived from a control group of dosimeters. The exit and entrance dose measurements are performed in quite different situations. To be able to achieve those two quantities with TLD, these should be independently calibrated according to the measurement conditions. Alternatively, we can use a single calibration, in entrance dose, and convert the result to the exit dose value by introducing some correction factors. These corrections are related to the different measurement depths and to the different backscattering contributions. We have proved that within an acceptable error we can perform a single calibration and adopt the correction factors which are energy and field size dependent. (author)

  7. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  8. Development of mathematical model for estimation of entrance surface dose in mammography

    International Nuclear Information System (INIS)

    Abdelgani, Yassir Mohammed Tahir

    2013-05-01

    Computer simulation is a convenient and frequently used tool in the study of x-ray mammography, for the design of novel detector systems, the evaluation of dose deposition, x-ray technique optimization, and other applications. An important component in the simulation process is the accurate computer generation of x-ray spectra. A computer model for the generation of x-ray spectra in the mammographic energy rang from 18 keV to 40 ke V has been developed by Boone et al. Due to the lack of QC and dose measurement tools, in addition to unavailability of medical physics, a mathematical tool was developed for estimation of patient exposure and entrance dose. The proposed model require no assumptions concerning the physics of x-ray production in an x-ray tube, but rather makes use of x-ray spectra recently measured experimentally by John M Boone (Department of Radiology, University of California). Using experimental dose measurements for specific tube voltage and tube current the generated x-ray spectra were calibrated. The spectrum calibration factors show a tube voltage dependency. From the calibrated x-ray spectrum, the exposure and entrance dose were estimated for different k Vp and m A. Results show good agreement between the measured and estimated values for tube voltage between 18 to 45 k Vp with a good correlation of nearly 1 and equal slope. The maximum estimated different between the measured and the simulated dose is approximately equal to 0.07%.(Author)

  9. Measurement and monitoring of entrance exposure dose rate in X-ray image intensifier television with dose rate control

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J [Bezirkskrankenhaus Brandenburg (German Democratic Republic)

    1981-03-01

    For X-ray image intensifier television operation very low entrance dose rates (about 5.2 nA/kg) are stated and demanded, respectively. These required values are often manifold exceeded in practice so that a check seems to be necessary. It is shown and proved how these measurements can be performed with simple, generally available means of measurement in the radiological practice. For ZnCdS-image intensifiers should be considered that about 13 nA/kg for the large entrance size are not to be exceeded; for the CsI type lower values (factor 1.5) are practicable because of the twofold quantum absorption efficiency. Furthermore, some tests for a semiquantitative function check of the automatic dose rate control are proposed.

  10. Entrances skin dose distribution maps for interventional neuroradiological procedures: A preliminary study

    International Nuclear Information System (INIS)

    Rampado, O.; Ropolo, R.

    2005-01-01

    Does estimation in interventional neuroradiology can be useful to limit skin radiation injuries. The purpose of this study was to evaluate the role of entrance skin dose (ESD) maps in planning exposure condition optimisation. Thirteen cerebral angiography and five embolisation procedures were monitored, measuring ESD, dose-area product (DAP) and other operational parameters. A transmission ionisation chamber, simultaneously measuring air kerma and DAP, measured dose-related quantities. Data acquisition software collected dosimetric and geometrical data during the interventional procedure and provided a distribution map of ESD on a standard phantom digital image, with maximum value estimation. Values of 88-1710 mGy for maximum skin dose and 16.7-343 Gy cm 2 for DAP were found. These data confirm the possibility of deterministic effects during therapeutic interventional neuroradiological procedures like cerebral embolisation. ESD maps are useful to retrospectively study the exposure characteristics of a procedure and plan patient exposure optimisation. (authors)

  11. Evaluation of radiological protection and dose of skin entrance in paediatric dentistry examinations

    International Nuclear Information System (INIS)

    Khoury, Helen Jamil; Silveira, Marcia Maria Fonseca da; Couto, Geraldo Bosco Lindoso; Brasileiro, Izabela Vanderley

    2005-01-01

    In this work the radiological protection conditions and dose at the entrance of pediatric patients undergoing dental intraoral radiographs were evaluated. The study was conducted in two clinics of the dentistry course at the Federal University of Pernambuco, Recife, PB, Brazil, equipped with conventional X-ray apparatus, with 60 and 70 kV. 254 exams of 113 patients between the ages of 3 to 12 years were evaluated. The skin entrance dose was estimated using TLD-100 thermoluminescent dosemeters. During the examination were also recorded information regarding the time of exposure, radiographic technique used, use of thyroid protectors and lead apron, angle and distance of the cone Locator to the patient's skin. The results showed that the input skin doses ranged from 0.3 mGy to 10mGy. The lead apron was used in 71% of exams while the thyroid shield was only used in 58% of the exams. The exposure times ranged from 0,5s to 1,5s. From the results it can be concluded that the radiological procedures are not optimized and that in some cases the patient dose is high.

  12. A Computer Program Method for Estimation of Entrance Skin Dose for some Individuals Undergoing X-ray Imaging

    International Nuclear Information System (INIS)

    Taha, T.M.; Allehyani, S.

    2012-01-01

    A computer program depends on practical measurements of entrance skin dose patients undergoing radiological examinations. Physical parameters such as field size, half value layer, backscatter factor, dose output, focal film distance, focal skin distance, normal operating conditions were taken into consideration for calculation entrance skin dose. It was measured by many techniques such as Thermo-luminescence dosimeters, ionization chambers. TLD technique characterized by high precision and reproducibility of dose measurement is checked by addressing pre-readout annealing, group sorting, dose evaluation, Fifty TLD chips were annealed for 1 hour at 400 degree C followed by 2 h at 100 degree C. After exposure to constant dose from X-ray generator. 0.6 cc Ionization chamber was located at surface of water chest phantom that has dimensions of 40 cm x 40 cm x 20 cm and connected with farmer dose master. Entrance Skin Dose was calculated using the generated software by changing the physical parameters and using the measured output doses. The obtained results were compared with the reference levels of International Atomic Energy Authority. The constructed computer program provides an easy and more practical mean of estimating skin dose even before exposure. They also provide the easiest and cheapest technique can be employed in any entrance skin dose measurement

  13. An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures

    International Nuclear Information System (INIS)

    Waite, J.C.; Fitzgerald, M.

    2001-01-01

    In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper compares three methods of monitoring entrance surface dose (ESD). It also reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs. Although the sample is small, the results reinforce the need for routine assessments to be made of ESDs in FGIPs. At present, the most reliable and accurate form of ESD measurement would seem to be arrays of TLDs. However, transducer based methods, although likely to be less accurate, have considerable advantages in relation to a continuous monitoring programme. It is also suggested that there may be the potential locally for threshold dose area product (DAP) values to be set for specific procedures. These could be used to provide early warning of the potential for skin injuries. (author)

  14. Entrance radiation doses during paediatric cardiac catheterizations performed for diagnosis or the treatment of congenital heart disease

    International Nuclear Information System (INIS)

    Papadopoulou, D.; Yakoumakis, Em; Sandilos, P.; Thanopoulos, V.; Makri, Tr; Gialousis, G.; Houndas, D.; Yakoumakis, N.; Georgiou, Ev

    2005-01-01

    The purpose of this study was to estimate the radiation exposure of children, during cardiac catheterizations for the diagnosis or treatment of congenital heart disease. Radiation doses were estimated for 45 children aged from 1 d to 13 y old. Thermoluminescent dosemeters (TLDs) were used to estimate the posterior entrance dose (D P ), the lateral entrance dose (D LAT ), the thyroid dose and the gonads dose. A dose-area product (DAP) meter was also attached externally to the tube of the angiographic system and gave a direct value in mGy cm 2 for each procedure. Posterior and lateral entrance dose values during cardiac catheterizations ranged from 1 to 197 mGy and from 1.1 to 250.3 mGy, respectively. Radiation exposure to the thyroid and the gonads ranged from 0.3 to 8.4 mGy to 0.1 and 0.7 mGy, respectively. Finally, the DAP meter values ranged between 360 and 33,200 mGy cm 2 . Radiation doses measured in this study are comparable with those reported to previous studies. Moreover, strong correlation was found between the DAP values and the entrance radiation dose measured with TLDs. (authors)

  15. Evaluation of entrance skin dose to the skull in diagnostic radiology

    International Nuclear Information System (INIS)

    Mohamed, Anas Ali Elbushari

    2015-12-01

    Diagnostic x-ray radiology is a common diagnostic practice.Despite of its increasing hazard to human beings, imaging procedures should be achieved with less radiation dose and sufficient image quality. The aim of this study was to estimate the entrance skin dose(ESD) for patients undergoing selected diagnostic x-ray examinations in four hospitals.The study included the examinations of the skull; posterior- anterior(PA) and lateral projections. Fifty patients were enrolled in this study. ESDs were estimated from patients specific exposure parameters using established relation between output (μGy/mAs) and tube voltage(kVp). The estimated ESDs ranged from 0.0097-0.1846 mGy for skull (PA), 0.0097-0.1399 mGy for skull (LAT). These values were acceptable as compared with the international reference dose levels. This study provides additional data that can help the regulatory authority to establish reference dose levels for diagnostic radiology in Sudan.(Author)

  16. Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization

    International Nuclear Information System (INIS)

    Sun, Lue; Mizuno, Yusuke; Goto, Takahisa; Iwamoto, Mari; Koguchi, Yasuhiro; Miyamoto, Yuka; Tsuboi, Koji; Chida, Koichi; Moritake, Takashi

    2014-01-01

    Children with complex congenital heart diseases often require repeated cardiac catheterization; however, children are more radiosensitive than adults. Therefore, radiation-induced carcinogenesis is an important consideration for children who undergo those procedures. We measured entrance skin doses (ESDs) using radio-photoluminescence dosimeter (RPLD) chips during cardiac catheterization for 15 pediatric patients (median age, 1.92 years; males, n = 9; females, n = 6) with cardiac diseases. Four RPLD chips were placed on the patient's posterior and right side of the chest. Correlations between maximum ESD and dose-area products (DAP), total number of frames, total fluoroscopic time, number of cine runs, cumulative dose at the interventional reference point (IRP), body weight, chest thickness, and height were analyzed. The maximum ESD was 80 ± 59 (mean ± standard deviation) mGy. Maximum ESD closely correlated with both DAP (r = 0.78) and cumulative dose at the IRP (r = 0.82). Maximum ESD for coiling and ballooning tended to be higher than that for ablation, balloon atrial septostomy, and diagnostic procedures. In conclusion, we directly measured ESD using RPLD chips and found that maximum ESD could be estimated in real-time using angiographic parameters, such as DAP and cumulative dose at the IRP. Children requiring repeated catheterizations would be exposed to high radiation levels throughout their lives, although treatment influences radiation dose. Therefore, the radiation dose associated with individual cardiac catheterizations should be analyzed, and the effects of radiation throughout the lives of such patients should be followed. (author)

  17. Evaluation of the Entrance Surface Dose (ESD and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-06-01

    Full Text Available Background Patients' dosimetry is crucial in order to enhance radiation protection optimization and to deliver low radiation dose to the patients in a radiological procedure. The aim of this study was to assess the entrance surface dose (ESD and radiation dose to the radiosensitive organs in pediatric pelvic radiography. Materials and Methods The studied population included 98 pediatric patients of both genders referred to anteroposterior (AP projection of pelvic radiography. The radiation dose was directly measured using high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD-GR200. Two TLDs were placed at the center point of the radiation field to measure the ESD of pelvis. Moreover for each patient, 2 TLDs were placed upon each eyelid, 2 TLDs upon each breast, 2 TLDs upon the surface anatomical position of the thyroid gland and finally 2 TLDs at the surface anatomical position of the gonads to measure the received dose. Results The ESD ± standard deviation for AP pelvic radiography was obtained 591.7±76 µGy. Statistically significant difference was obtained between organs located outside and inside of the radiation field with respect to dose received (P

  18. Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool

    Energy Technology Data Exchange (ETDEWEB)

    Brady, S. L., E-mail: samuel.brady@stjude.org; Kaufman, R. A., E-mail: robert.kaufman@stjude.org [Department of Diagnostic Imaging, St. Jude Children’s Research Hospital, Memphis, Tennessee 38105 (United States)

    2015-05-15

    Purpose: To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Methods: Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken from DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k{sub air}) value based on an x-ray characteristic radiation output curve; (2) scaling k{sub air} with a BSF value; and (3) correcting k{sub air} for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass–energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. Results: ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19–0.42 mGy for dual view chest, 0.28–1.2 mGy for AP abdomen, 0.18–0.65 mGy for LAT view skull, 0.15–0.63 mGy for dual view knee, and 0.10–0.12 mGy for bone age (left hand) examinations. Conclusions: A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for

  19. Methods for implementation of in vivo dosimetry (entrance dose) using thermoluminescent dosimeters during radiotherapy treatment with photon beam

    International Nuclear Information System (INIS)

    Barsanelli, Cristiane

    2006-01-01

    Selection, calibration procedure to convert TLD signal into absorbed dose and physical characteristics at the thermoluminescent dosimeters, as well as the determination of correction factors and the methodology to determine expected entrance dose, are described in this work. Practical aspects and the utility of entrance dose measures with thermoluminescent dosimeters were investigated, as well as the exactness and the reproducibility of the daily dose release. The entrance dose measures were performed in five patients with diagnosis of breast cancer treated with a 6 MV photon beam. The measured dose and the expected dose values agreed in ± 5%, due to excellent treatment equipment stability, to automatic verification system and the good exactness in the daily treatment adjustment. Good precision can be achieved when the correction factors for each parameter of influence in the dosimeter response are carefully determined and applied to convert the thermoluminescent signal into absorbed dose. The study demonstrates the viability of thermoluminescent dosimeters use for in vivo dosimetry and its utility as part of a quality assurance program in a radiation therapy service. (author)

  20. Estimation of entrance dose during selected fluoroscopic examinations in some hospitals in Khartoum state

    International Nuclear Information System (INIS)

    Mohammed, Heba Abdalkareem Osman

    2016-01-01

    A diagnostic fluoroscopy is a modality that involves visualizing the anatomy using radiation in real time. Therefore, patients doses have a potential for being great, increasing the chance of the radiation induced carcinogenesis. The objective of this study was to determine the mean entrance surface dose (ESD) from selected fluoroscopic examinations namely, hysterosalpingography (HSG) and ascendingurethogram (ASU) in three hospitals in Khartoum State. A total of 87 and 110 patents for HSG and ASU respectively were examined. The data were collected over four months. The mean ESD for patients who underwent HSG were 16.2 mGy, 20.6 mGy and 25.9 mGY respectively, while the ESD for patient who underwent ascendingurethrogram for AP view were 3.5mGy, 2.9mGy and 11.9mGy and for OB view 15.9 mGy, 18.3 mGy and 25.4 mGy. Patient doses were calculated using mathematical equation and the results were compared with the ESDs calculated using mathematical equation and the results were found to be comparable with the ESDs reported in previous studies and within the guidance level established by the ICRP. Fluoroscopy time, operator skills, x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported in the measured ESDs. The study demonstrated the need for standardization of techniques throughout the hospitals and suggested that there ia a need to optimize the procedures.(Author)

  1. Sed and Awk

    CERN Document Server

    Dougherty, Dale

    1997-01-01

    sed & awk describes two text processing programs that are mainstays of the UNIX programmer's toolbox. sed is a "stream editor" for editing streams of text that might be too large to edit as a single file, or that might be generated on the fly as part of a larger data processing step. The most common operation done with sed is substitution, replacing one block of text with another. awk is a complete programming language. Unlike many conventional languages, awk is "data driven" -- you specify what kind of data you are interested in and the operations to be performed when that data is found

  2. Characteristic evaluation of a real-time silicon dosimeter and measurement of entrance surface dose at radiography

    International Nuclear Information System (INIS)

    Fujibuchi, Toshiou; Kato, Hideyuki; Hashimoto, Masatoshi; Abe, Yukinao; Kikawa, Takashi

    2006-01-01

    It is important to grasp how much radiation exposure has occurred through radiation diagnosis, in respect to patient explanations and radiation protection. In this examination, we used a patient skin dosimeter (PSD) that measures entrance surface dose (ESD) in real time using a fluoroscopy procedure. The PSD has the ability to display results beginning at 1 μGy. We focused our attention on the X-ray detectability of the PSD, and performed a representative evaluation with the X-ray equipment. We measured ESD under various radiographic parameters at our facility. Although the measurements were dependent on energy, we were able to measure ESD to within an accuracy of about a 5% error by putting a calibration value on energy. The PSD can measure ESD easily without requiring preparation. It is important to be aware of the exposure dose to the radiation staff, and the PSD is a very effective radiation dose-measuring tool when daily business is active. (author)

  3. Evaluation of the entrance skin dose due to paediatric chest X-rays examinations carried out at a great hospital in Rio de Janeiro city

    International Nuclear Information System (INIS)

    Mohamadain, K.E.M.; Azevedo, A.C.P.; Rosa, L.A.R. da; Mota, H.C.; Goncalves, O.D.; Guebel, M.R.N.

    2001-01-01

    A dosimetric survey in paediatric radiology is currently being carried out at the paediatric unit of a great hospital in Rio de Janeiro city, aiming the assessment of patient doses and image quality. The aim of this work was to estimate the entrance skin dose for frontal and lateral chest X-rays exposure to paediatric patients. Three examination techniques were investigated, namely PA, AP and lateral positions. For entrance skin dose evaluation, two different TL dosimeters were used, namely LiF:Mg,Ti and CaSO4:Dy. The age intervals considered were 0-1 year, 1-5 years, 5-10 years and 10-15 years. The results obtained with both dosimeters are similar and the entrance skin dose values evaluated for the different age intervals considered are compared with previous values found in Brazil and also in Europe. (author)

  4. Estimation of entrance dose on chest radiographs according to the exposure index on Computerized Radiology System: preliminary results; Estimativa de dose de entrada a partir do indice de exposicao em sistema CR: resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Donomai, Luana Kaoru; Jornada, Tiago da Silva; Daros, Kellen Adriana Curci, E-mail: luana.donomai@gmail.com, E-mail: tiagosjornada@gmail.com, E-mail: daros.kellen@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil)

    2014-07-01

    Digital radiology has improved image quality in radiographs in comparison to screen/film systems though the visual control of the quantity of radiation involved on these exams became more demanding due to the low perception of over and underexposed images. Therefore, this study aims to analyze the exposure index (EI) from chest examinations and relate them to the entrance skin dose. Indices from 29 patients and kerma entrance dose were correlated. A correlation coefficient equal to 0,6881 was calculated. EI and entrance dose are correlated positive and moderately, indicating the relevance to deepen the subject. (author)

  5. GOSSIP: SED fitting code

    Science.gov (United States)

    Franzetti, Paolo; Scodeggio, Marco

    2012-10-01

    GOSSIP fits the electro-magnetic emission of an object (the SED, Spectral Energy Distribution) against synthetic models to find the simulated one that best reproduces the observed data. It builds-up the observed SED of an object (or a large sample of objects) combining magnitudes in different bands and eventually a spectrum; then it performs a chi-square minimization fitting procedure versus a set of synthetic models. The fitting results are used to estimate a number of physical parameters like the Star Formation History, absolute magnitudes, stellar mass and their Probability Distribution Functions.

  6. Multicenter study on evaluation of the entrance skin dose by a direct measurement method in cardiac interventional procedures

    International Nuclear Information System (INIS)

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi

    2016-01-01

    Deterministic effects have been reported in cardiac interventional procedures. To prevent radiation skin injuries in percutaneous coronary intervention (PCI), it is necessary to measure accurate patient entrance skin dose (ESD) and maximum skin absorbed dose (MSD). We measured the MSD on 62 patients in four facilities by using the Chest-RADIREC system. The correlation between MSD and fluoroscopic time, dose area product (DAP), and cumulative air kerma (AK) showed good results, with the correlation between MSD and AK being the strongest. The regression lines using MSD as an outcome value (y) and AK as predictor variables (x) was y=1.18x (R 2 =0.787). From the linear regression equation, MSD is estimated to be about 1.18 times that of AK in real time. The Japan diagnostic reference levels (DRLs) 2015 for IVR was established by the use of dose rates using acrylic plates (20 cm thick) at the interventional reference point. Preliminary reference levels proposed by International Atomic Energy Agency (IAEA) were provided using DAP. In this study, AK showed good correlation most of all. Hence we think that Japanese DRLs for IVR should reconsider by clinical patients' exposure dose such as AK. (author)

  7. Skin Entrance dose to patients from routine P-A chest X-ray ...

    African Journals Online (AJOL)

    Background: Radiation of any amount is potentially hazardous and it should be minimized as much as possible during health care delivery. Objective: To determine and assess the variation of the dose received by patients undergoing chest x-ray examination, and to provide a useful baseline data to evaluate the dose to the ...

  8. A comparison of entrance skin dose delivered by clinical angiographic c-arms using the real-time dosimeter: the MOSkin

    International Nuclear Information System (INIS)

    Thorpe, Nathan K.; Cutajar, Dean; Lian, Cheryl; Rosenfeld, Anatoly; Pitney, Mark; Friedman, Daniel; Perevertaylo, Vladimir

    2016-01-01

    Coronary angiography is a procedure used in the diagnosis and intervention of coronary heart disease. The procedure is often considered one of the highest dose diagnostic procedures in clinical use. Despite this, there is minimal use of dosimeters within angiographic catheterisation laboratories due to challenges resulting from their implementation. The aim of this study was to compare entrance dose delivery across locally commissioned c-arms to assess the need for real-time dosimetry solutions during angiographic procedures. The secondary aim of this study was to establish a calibration method for the MOSkin dosimeter that accurately produces entrance dose values from the clinically sampled beam qualities and energies. The MOSkin is a real-time dosimeter used to measure the skin dose delivered by external radiation beams. The suitability of the MOSkin for measurements in the angiographic catheterisation laboratory was assessed. Measurements were performed using a 30 × 30 × 30cm 3 PMMA phantom positioned at the rotational isocenter of the c-arm gantry. The MOSkin calibration factor was established through comparison of the MOSkin response to EBT2 film response. Irradiation of the dosimeters was performed using several clinical beam qualities ranging in energy from 70 to 105 kVp. A total of four different interventional c-arm machines were surveyed and compared using the MOSkin dosimeter. The phantom was irradiated from a normal angle of incidence using clinically relevant protocols, field sizes and source to image detector distance values. The MOSkin was observed to be radiotranslucent to the c-arm beam in all clinical environments. The MOSkin response was reproducible to within 2 % of the average value across repeated measurements for each beam setting. There were large variations in entrance dose delivery to the phantom between the different c-arm machines with the highest observed cine-acquisition entrance dose rate measuring 326 % higher than the lowest

  9. Assessment of Patients’ Entrance Skin Dose from Diagnostic X-ray Examinations at Public Hospitals of Akwa Ibom State, Nigeria

    Directory of Open Access Journals (Sweden)

    Esen Nsikan U

    2015-07-01

    Full Text Available Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State, Nigeria. Materials and Methods In total, six examinations were performed on 720 patients in this study.   CALDose_X5 software program was used in estimating ESDs based on patients’ information and technical exposure parameters. Results The estimated ESDs ranged from 0.59 to 0.61 mGy for PA and RLAT projections of the thorax, respectively. ESDs for the AP and RLAT projections of the cranium were 1.65 and 1.48 mGy, respectively. Also, ESD values for the AP view of the abdomen and pelvis were 1.89 and 1.88 mGy, respectively. The mean effective dose was within the range of 0.021-0.075 mGy for the thorax (mean= 0.037, 0.008-0.045 mGy for the cranium (mean= 0.016, 0.215-0.225 mGy for the abdomen (mean= 0.219 and 0.101-0.119 mGy for the pelvis (mean= 0.112. Conclusion The obtained results were comparable to the international reference dose levels, except for the PA projection of the thorax. Therefore, quality assurance programs are required in diagnostic X-ray units of Nigeria hospitals. The obtained findings add to the available data and can help authorities establish reference dose levels for diagnostic radiography in Nigeria.

  10. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    International Nuclear Information System (INIS)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L.; Filho, A. M.

    2014-08-01

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  11. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L. [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Filho, A. M., E-mail: venezianigr@gmail.com [Centro Universitario de Rio Petro - UNIRP, Rodovia Br 153 (Transbrasiliana), Km. 69 Sao Jose do Rio Preto, Sao Paulo (Brazil)

    2014-08-15

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  12. In vivo dosimetry: measurement of entrance and exit dose using MOSFET dosimeter

    International Nuclear Information System (INIS)

    Gopiraj, A.; Billimagga, Ramesh S.; Rekha, M.; Ramasubramaniam, V.

    2007-01-01

    Patient dose verification is an essential part of a Quality Assurance (QA) program in a Radiotherapy Department. As the transition is made from the conventional two-dimensional (2D) to three-dimensional (3D) conformal and intensity modulated therapy, it is recommended that new treatment techniques be checked systematically to guarantee accurate dose delivery by means of a comprehensive in vivo dosimetry program (i.e. real-time dosimetry during patient treatment). The authors conducted a study to assess the clinical utility of in vivo dosimetry in the Dept. of Radiation Oncology using MOSFET dosimetry system

  13. Evaluation of skin entrance radiation dose in pediatric patients undergoing chest X-rays exams

    International Nuclear Information System (INIS)

    Gabardo, Farly Piantini

    2016-01-01

    The aim of this work was to estimate the incident air kerma of lateral (LAT) and anterior-posterior (AP) together with posterior-anterior (PA) projection chest X-ray exams in one of the largest pediatric hospitals in Brazil. Dosimetric results are accompanied with the detailed analysis of patient characteristics and radiographer strategy. The exams of 225 (119 male and 106 female) patients were studied and 389 X-ray exams (200 AP/PA projections and 189 LAT projections) of pediatric patients were acquired. Patient thickness can be restored from age, height or weight with the uncertainty of ∼20-30%. Very slight correlation between the patient dose and thickness was observed with the difference in dose for patients of the same thickness reaching 4 times. By standardization of radiological protocols, it should be possible to keep dose within the intervals 50-100 μGy for LAT projection and 40-80 μGy for AP/PA projection. The dose values are lower than those recommended by major European guidelines to good practice. (author)

  14. Evolution of Entrance Surface Doses and Image Quality in Pediatric Chest Radiographs

    International Nuclear Information System (INIS)

    Campello, A.C.; Marques, D.T.; Medeiros, C.B.; Carvalho, P.P.; Khoury, H.J.; Azevedo, A.C.P.

    2006-01-01

    This work presents the results of a survey about image quality, radiographic techniques and patient doses in a large public hospital located in the city of Recife, Brazil. It was detected that the quality criteria are not fully reached and represent 70% of the agreement with recommendations from the European Community. Concerning the radiographic techniques the kV is in accordance with international recommendations in 90% if the examinations while the exposure time is 72%. The results also show that the dose values change in the range from 0.020 to 0.250 mGy. The variability is mainly caused by the disparity on the radiographic techniques employed in the examinations as well as by the radiographer's expertise. It could be concluded that the ALARA principle is not being applied in the hospital, which becomes a concern in terms of public health. (author)

  15. Results of the study of entrance surface dose from conventional examinations in diagnostic radiology

    International Nuclear Information System (INIS)

    Martinez, A.; Jova, L.; Carrazana, J.; Diaz, E.; Mora, R. de la; Guevara, C.; Fleitas, I.

    2001-01-01

    The wide diffusion of X-ray diagnostic together with the quick development and expansion that has come with experiencing the technology in this practice, has motivated the emission of recommendations in the Basic Safety Standards of the IAEA for the establishment of guidance levels for different radiological examinations in each country that allow the optimization of the medical exposure. Considering the above-mentioned and the existence in Cuba in a great number of conventional X-ray equipment, with an average of over 10 years of use which influences directly on the patient dose, in 1999, an investigation began in the country on the patient exposure in this practice. This work shows the first results of measurements carried out in 9 major hospitals of several provinces of the country. The doses were evaluated in the examinations of lumbar spine AP, lumbar spine LAT, thorax PA, skull AP and skull LAT. The determination of the doses in these examinations was carried out by 'in-vivo' measurements on the patients, placing in the center of the irradiation field TLD of LiF. The distributions obtained in the studies are compared with the guidance levels that is shown in the Basic Safety Standards of the IAEA. (author)

  16. Cancer radiotherapy based on femtosecond IR laser-beam filamentation yielding ultra-high dose rates and zero entrance dose.

    Science.gov (United States)

    Meesat, Ridthee; Belmouaddine, Hakim; Allard, Jean-François; Tanguay-Renaud, Catherine; Lemay, Rosalie; Brastaviceanu, Tiberius; Tremblay, Luc; Paquette, Benoit; Wagner, J Richard; Jay-Gerin, Jean-Paul; Lepage, Martin; Huels, Michael A; Houde, Daniel

    2012-09-18

    Since the invention of cancer radiotherapy, its primary goal has been to maximize lethal radiation doses to the tumor volume while keeping the dose to surrounding healthy tissues at zero. Sadly, conventional radiation sources (γ or X rays, electrons) used for decades, including multiple or modulated beams, inevitably deposit the majority of their dose in front or behind the tumor, thus damaging healthy tissue and causing secondary cancers years after treatment. Even the most recent pioneering advances in costly proton or carbon ion therapies can not completely avoid dose buildup in front of the tumor volume. Here we show that this ultimate goal of radiotherapy is yet within our reach: Using intense ultra-short infrared laser pulses we can now deposit a very large energy dose at unprecedented microscopic dose rates (up to 10(11) Gy/s) deep inside an adjustable, well-controlled macroscopic volume, without any dose deposit in front or behind the target volume. Our infrared laser pulses produce high density avalanches of low energy electrons via laser filamentation, a phenomenon that results in a spatial energy density and temporal dose rate that both exceed by orders of magnitude any values previously reported even for the most intense clinical radiotherapy systems. Moreover, we show that (i) the type of final damage and its mechanisms in aqueous media, at the molecular and biomolecular level, is comparable to that of conventional ionizing radiation, and (ii) at the tumor tissue level in an animal cancer model, the laser irradiation method shows clear therapeutic benefits.

  17. Dose estimation at the entrance of the skin in diagnostic imaging equipment using distributions of workloads

    International Nuclear Information System (INIS)

    Pereira, Paula A.A.; Furquim, Tania A.C.; Costa, Paulo R.

    2005-01-01

    The work proposed to implement workload distributions with respect to radiological equipment of different technologies, the input dose calculation in the skin (DEP). With the results of the survey in the field (radiological clinics and hospitals of the city of Sao Paulo, SP, Brazil), a methodology was studied for the application of this information in the calculation of DEP and the application of statistical treatment of results of measurements performed. With the results, we can conclude that the choice of the appropriate number of samples is important in order to obtain statistically acceptable values. In addition, it can be concluded that the method presented is valid because the DEP found values are very close to the values calculated by other methods previously developed by the authors

  18. Photon dose evaluation at the entrance of radiotherapy bunkers without maze

    International Nuclear Information System (INIS)

    Facure, Alessandro; Salata, Camila

    2017-01-01

    Radiation protection has become an important field of study, as the use of ionizing radiation for diagnosis and therapy increased along the years. According to the ALARA principles, shielding is one of the most efficient ways to minimize radiation exposure. Linear accelerators for radiotherapy treatment can lead to a considerable risk due to radiation for public and workers if proper shielding is not calculated. Mazeless rooms for LINACS are becoming more usual, as they need less space to be constructed, but, on the other hand they are more expensive. The doors of those kinds of rooms are an important point, as they will have to be thicker in mazelles room to proper shield the radiation. The NCRP 151 lays out the general considerations for the shielding calculation of standard rooms, with mazes, but there are no specific recommendations for mazeless rooms on literature. The work herein presented evaluated the absorbed dose in a room model without maze, which will be constructed soon in Brazil. The applicant calculated the thickness of the door as if it was a room with maze, and the authors used computational simulation wit MCNP code to simulate the same room, and calculated the door thickness as if it was a secondary barrier. The dose limit considered was for public occupation, 1 mSv/sem, and the energy beam was of 6 MeV. The simulated results showed that the applicant calculation thickness for the door was underestimated in 88%. The obtained results are important to establish a better methodology for shielding calculation of mazeless radiotherapy rooms that are becoming more common in Brazil. (author)

  19. Photon dose evaluation at the entrance of radiotherapy bunkers without maze

    Energy Technology Data Exchange (ETDEWEB)

    Facure, Alessandro; Salata, Camila, E-mail: facure@cnen.gov.br, E-mail: camila.salata@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de janeiro, RJ (Brazil)

    2017-07-01

    Radiation protection has become an important field of study, as the use of ionizing radiation for diagnosis and therapy increased along the years. According to the ALARA principles, shielding is one of the most efficient ways to minimize radiation exposure. Linear accelerators for radiotherapy treatment can lead to a considerable risk due to radiation for public and workers if proper shielding is not calculated. Mazeless rooms for LINACS are becoming more usual, as they need less space to be constructed, but, on the other hand they are more expensive. The doors of those kinds of rooms are an important point, as they will have to be thicker in mazelles room to proper shield the radiation. The NCRP 151 lays out the general considerations for the shielding calculation of standard rooms, with mazes, but there are no specific recommendations for mazeless rooms on literature. The work herein presented evaluated the absorbed dose in a room model without maze, which will be constructed soon in Brazil. The applicant calculated the thickness of the door as if it was a room with maze, and the authors used computational simulation wit MCNP code to simulate the same room, and calculated the door thickness as if it was a secondary barrier. The dose limit considered was for public occupation, 1 mSv/sem, and the energy beam was of 6 MeV. The simulated results showed that the applicant calculation thickness for the door was underestimated in 88%. The obtained results are important to establish a better methodology for shielding calculation of mazeless radiotherapy rooms that are becoming more common in Brazil. (author)

  20. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    Science.gov (United States)

    Kavuma, Awusi; Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2010-01-01

    In vivo dosimetry is one of the quality assurance tools used in radiotherapy to monitor the dose delivered to the patient. Electronic portal imaging device (EPID) images for a set of solid water phantoms of varying thicknesses were acquired and the data fitted onto a quadratic equation, which relates the reduction in photon beam intensity to the attenuation coefficient and material thickness at a reference condition. The quadratic model is used to convert the measured grey scale value into water equivalent path length (EPL) at each pixel for any material imaged by the detector. For any other non-reference conditions, scatter, field size and MU variation effects on the image were corrected by relative measurements using an ionization chamber and an EPID. The 2D EPL is linked to the percentage exit dose table, for different thicknesses and field sizes, thereby converting the plane pixel values at each point into a 2D dose map. The off-axis ratio is corrected using envelope and boundary profiles generated from the treatment planning system (TPS). The method requires field size, monitor unit and source-to-surface distance (SSD) as clinical input parameters to predict the exit dose, which is then used to determine the entrance dose. The measured pixel dose maps were compared with calculated doses from TPS for both entrance and exit depth of phantom. The gamma index at 3% dose difference (DD) and 3 mm distance to agreement (DTA) resulted in an average of 97% passing for the square fields of 5, 10, 15 and 20 cm. The exit dose EPID dose distributions predicted by the algorithm were in better agreement with TPS-calculated doses than phantom entrance dose distributions.

  1. Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.

    Science.gov (United States)

    Yoo, Wook Jae; Shin, Sang Hun; Jeon, Dayeong; Hong, Seunghan; Sim, Hyeok In; Kim, Seon Geun; Jang, Kyoung Won; Cho, Seunghyun; Youn, Won Sik; Lee, Bongsoo

    2014-04-01

    A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA) chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  2. Clinical results of entrance dose in vivo dosimetry for high energy photons in external beam radiotherapy using MOSFETs

    International Nuclear Information System (INIS)

    Morton, J. P.; Bhat, M.; Williams, T.; Kovendy, A.

    2007-01-01

    Full text: Thomson and Nielsen T N -502 R D MOSFETs were used for entrance dose in vivo dosimetry for 6 and 10 MV photons. A total of 24 patients were tested, 10 breast. 8 prostate, 5 lung and 1 head and neck. For prostates three fields were checked. For all other plans all fields were checked. An action threshold of 8% was set for any one field and 5% for all fields combined. The total number of fields tested was 56, with a mean discrepancy of 1.4% and S.D. of 2.6%. Breasts had a mean discrepancy of 1.8% and S.D. of 2.8%. Prostates had a mean discrepancy of 1.3% and S.D. of 2.9%. For 3 fields combined, prostates had a mean of 1.3% and S.D. of 1.8%. These results are similar to results obtained with diodes and TLDs for the same techniques.

  3. Measurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter

    Directory of Open Access Journals (Sweden)

    Wook Jae Yoo

    2014-04-01

    Full Text Available A miniature fiber-optic dosimeter (FOD system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  4. Assessment of entrance skin doses for patients undergoing diagnostic X-ray examinations in some major hospitals of Uttarakhand, India

    International Nuclear Information System (INIS)

    Uniyal, S.C.; Prasad, V.; Chaturvedi, V.; Raghuvanshi, S.; Sharma, S.D.

    2016-01-01

    Entrance skin dose (ESD) was calculated based on the X-ray beam output, the exposure parameters used for the actual examination and the standard value of backscatter factor. Descriptive statistics were generated from the data by using Microsoft Excel 2010. The third quartile values of ESDs obtained in this study for different X-ray projections of chest anterior-posterior (AP), chest posterior-anterior (PA), cervical spine, thoracic spine, lumber spine AP, lumber spine lateral, abdomen, KUB, pelvis, skull and knee joint were 0.79, 0.28, 1.20, 2.80, 4.26, 9.82, 2.68, 3.21, 2.69, 2.21 and 0.55 mGy respectively. The ratio of maximum to minimum ESD values ranges from 5.2 for thoracic spine to 19.76 for chest AP X-ray examinations. In general, the obtained ESD values were found to be either lower than or in agreement with the reported national/international values

  5. An investigation of entrance surface dose calculations for diagnostic radiology using Monte Carlo simulations and radiotherapy dosimetry formalisms

    International Nuclear Information System (INIS)

    Omrane, L Ben; Verhaegen, F; Chahed, N; Mtimet, S

    2003-01-01

    Our aim in this work was to investigate the methodology used in the determination of the entrance surface dose (ESD) in diagnostic radiology. In kV x-rays for low-energy photons (tube potential up to 160 kV, HVL: 1-8 mm Al), the ESD is based on the use of the ratio of mass-energy absorption coefficients and backscatter factors. A full simulation of the photon and electron transport in a kilovoltage x-ray unit, using the Monte Carlo code BEAM/EGS4, was performed to obtain an accurate beam phase space for use in dose calculation. The modelled phase space was experimentally validated for the beam qualities (measured HVL: 3.3 mm Al-2.2 mm Cu) and showed good agreement between calculated and measured HVLs, air kerma and relative dose distributions. We have computed the conversion factors from air kerma to water or soft tissue absorbed dose at the surface of a phantom for beam qualities (HVL: 3.3-8.35 mm Al). The same model was also used to calculate the ESD in water and in soft tissue for the low-energy photon range considered. The results show that the numerical differences between the air kerma and the water kerma based backscatter factors are insignificant. The same conclusion was reached for the (μ en /ρ) ratios, for soft tissue to air, evaluated using either the primary photon spectra or the spectra at the surface of a phantom. Furthermore, the good agreement obtained for the computation of the conversion factors with a full BEAM/EGS4 model confirms the previous studies which are based on different sources for the spectral distribution and different beam geometries (pencil beam or point source assumptions). On the other hand, the ESD in water or soft tissue is well described either with the B air or the B w formalism. Conversion factors from air kerma to ESD in these media are proposed in this work for several beam qualities in diagnostic radiology

  6. Sensitivity of coefficients for converting entrance surface dose and kerma-area product to effective dose and energy imparted to the patient

    International Nuclear Information System (INIS)

    Wise, K.N.; Sandborg, M.; Persliden, J.; Alm Carlsson, G.

    1999-01-01

    We investigate the sensitivity of the conversions from entrance surface dose (ESD) or kerma-area product (KAP) to effective dose (E) or to energy imparted to the patient (ε) to the likely variations in tube potential, field size, patient size and sex which occur in clinical work. As part of a factorial design study for chest and lumbar spine examinations, the tube potentials were varied to be ±10% of the typical values for the examinations while field sizes and the positions of the field centres were varied to be representative of values drawn from measurements on patient images. Variation over sex and patient size was based on anthropomorphic phantoms representing males and females of ages 15 years (small adult) and 21 years (reference adult). All the conversion coefficients were estimated using a mathematical phantom programmed with the Monte Carlo code EGS4 for all factor combinations and analysed statistically to derive factor effects. In general, the factors studied behaved independently in the sense that interaction of the physical factors generally gave no more than a 5% variation in a conversion coefficient. Taken together, variation of patient size, sex, field size and field position can lead to significant variation of E/KAP by up to a factor of 2, of E/ESD by up to a factor of 3, of ε/KAP by a factor of 1.3 and of ε/ESD by up to a factor of 2. While KAP is preferred to determine ε, the results show no strong preference of KAP over ESD in determining E. The mean absorbed dose D-bar in the patient obtained by dividing ε (determined using KAP) by the patient's mass was found to be the most robust measure of E. (author)

  7. Scan Quality and Entrance Skin Dose in Thoracic CT: A Comparison between Bismuth Breast Shield and Posteriorly Centered Partial CT Scans

    International Nuclear Information System (INIS)

    Tappouni, Rafel; Mathers, Bradley

    2012-01-01

    Objectives. To compare the effectiveness of the bismuth breast shield and partial CT scan in reducing entrance skin dose and to evaluate the effect of the breast shield on image quality (IQ). Methods. Nanodots were placed on an adult anthropomorphic phantom. Standard chest CT, CT with shield, and partial CT were performed. Nanodot readings and effective doses were recorded. 50 patients with chest CTs obtained both with and without breast shields were reviewed. IQ was evaluated by two radiologists and by measuring Hounsfield units (HUs) and standard deviation (SD) of HU in anterior subcutaneous region. Results. Breast shield and the partial CT scans reduced radiation to the anterior chest by 38% and 16%, respectively. Partial CT increased dose to the posterior chest by 37% and effective dose by 8%. Change in IQ in shield CT was observed in the anterior chest wall. Significant change in IQ was observed in 5/50 cases. The shield caused an increase of 20 HU (P = 0.021) and a 1.86 reduction in SD of HU (P = 0.027) in the anterior compared to posterior subcutaneous regions. Summary. Bismuth breast shield is more effective than the partial CT in reducing entrance skin dose while maintaining image quality

  8. Fundamental study on the characteristics of a radiophotoluminescence glass dosemeter with no energy compensation filter for measuring patient entrance doses in cardiac interventional procedures

    International Nuclear Information System (INIS)

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi; Koguchi, Yasuhiro; Sato, Tadaya; Kadowaki, Ken; Oosaka, Hajime; Tosa, Tetsuo

    2014-01-01

    Cardiac interventional procedures have been increasing year by year. However, radiation skin injuries have been still reported. There is a necessity to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not been established. To measure the ESD, a lot of radiophotoluminescence dosemeters (RPLDs) provide an accurate measurement of the direct actual ESD at the points they are arrayed. The purpose of this study was to examine the characteristics of RPLD to measure the ESD. As a result, X-ray permeable RPLD (with no tin filter) did not interfere with the percutaneous coronary intervention procedure. The RPLD also had good fundamental performance characteristics. Although the RPLD had a little energy dependence, it showed excellent dose and dose-rate linearity, and good angular dependence. In conclusion, by calibrating the energy dependence, RPLDs are useful dosemeter to measure the ESD in cardiac intervention. (authors)

  9. Strategic Employee Development (SED) Program

    Science.gov (United States)

    Nguyen, Johnny; Guevara (Castano), Nathalie; Thorpe, Barbara; Barnett, Rebecca

    2017-01-01

    As with many other U.S. agencies, succession planning is becoming a critical need for NASA. The primary drivers include (a) NASAs higher-than-average aged workforce with approximately 50 of employees eligible for retirement within 5 years; and (b) employees who need better developmental conversations to increase morale and retention. This problem is particularly concerning for Safety Mission Assurance (SMA) organizations since they traditionally rely on more experienced engineers and specialists to perform their organizations functions.In response to this challenge, the Kennedy Space Center (KSC) SMA organization created the Strategic Employee Development (SED) program. The SED programs goal is to provide a proactive method to counter the primary drivers by creating a deeper bench strength and providing a more comprehensive developmental feedback experience for the employee. The SED is a new succession planning framework that enables customization to any organization, and in this case, specifically for an SMA organization. This is accomplished via the identification of key positions, the corresponding critical competencies, and a process to help managers have relevant and meaningful development conversations with the workforce. As a result of the SED, several tools and products were created that allows management to make better strategic workforce decisions. Although there are opportunities for improvement for the SED program, the most important impact has been on the quality of developmental discussions for employees.

  10. Fundamental study on the characteristics of a radiophotoluminescence glass dosemeter with no energy compensation filter for measuring patient entrance doses in cardiac interventional procedures.

    Science.gov (United States)

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi; Koguchi, Yasuhiro; Sato, Tadaya; Oosaka, Hajime; Tosa, Tetsuo; Kadowaki, Ken

    2014-12-01

    Cardiac interventional procedures have been increasing year by year. However, radiation skin injuries have been still reported. There is a necessity to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not been established. To measure the ESD, a lot of radiophotoluminescence dosemeters (RPLDs) provide an accurate measurement of the direct actual ESD at the points they are arrayed. The purpose of this study was to examine the characteristics of RPLD to measure the ESD. As a result, X-ray permeable RPLD (with no tin filter) did not interfere with the percutaneous coronary intervention procedure. The RPLD also had good fundamental performance characteristics. Although the RPLD had a little energy dependence, it showed excellent dose and dose-rate linearity, and good angular dependence. In conclusion, by calibrating the energy dependence, RPLDs are useful dosemeter to measure the ESD in cardiac intervention. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Analysis of entrance skin radiation dose in mammography equipment in Rio Grande do Sul state (Ijui municipality and surroundings) and Rio de Janeiro (metropolitan area)

    International Nuclear Information System (INIS)

    Araujo, Geovane Silva; Padilha Filho, Lucas Gomes; Sousa, Carlos Henrique Simoes de; Feldmann, Gerson; Albrecht, Marcos R.A.; Souza, Sergio Augusto Lopes de

    2016-01-01

    Mammography is the technique widely used to the early detection of breast cancer, despite of not being a consensus the ideal age to initiate the radiologic examinations, it is recommended that women with the age of forty realize the examinations periodically. With the objective to analyze the entrance skin dose (ESD) in different mammography equipment, Were analyzed in the Estate of Rio Grande do Sul (Ijui City and neighborhoods) and in Rio de Janeiro (metropolitan area) 24 mammography equipment. Among them included in the study, just one presented ESD higher than the established limit of ANVISA. It was observed in the mammography equipment of Ijui and neighborhoods high levels of mAs to achieve the values of ESD next to the limit. (author)

  12. Modelling and interpretation of SEDs*

    Directory of Open Access Journals (Sweden)

    Woitke Peter

    2015-01-01

    Full Text Available Circumstellar disks are mostly detected by larger continuum fluxes in the infrared to mm spectral regions as compared to naked stars (a flux excess. The analysis of the Spectral Energy Distribution (SED of that flux excess was crucial for the development of the first theories about protoplanetary disks, and even nowadays, it is still one of the major tools to physically characterise the disks in terms of their mass, inner holes and gaps, vertical extension & shape, dust properties, and evolutionary state. In this chapter, we will review some of the early simple theories, show some examples, discuss the influence of typical disk shape and dust size parameters in modern SED analysis, and discuss how degenerate the results can be.

  13. Evaluation of radiological protection and dose of skin entrance in paediatric dentistry examinations; Avaliacao da protecao radiologica e da dose de entrada na pele em exames de odontologia pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Khoury, Helen Jamil [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Vasconcelos, Flavia Maria Nassar de [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Silveira, Marcia Maria Fonseca da [Universidade de Pernambuco (UPE), Recife, PE (Brazil). Fac. de Odontologia; Couto, Geraldo Bosco Lindoso [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Fac. de Odontopediatria; Brasileiro, Izabela Vanderley

    2005-07-01

    In this work the radiological protection conditions and dose at the entrance of pediatric patients undergoing dental intraoral radiographs were evaluated. The study was conducted in two clinics of the dentistry course at the Federal University of Pernambuco, Recife, PB, Brazil, equipped with conventional X-ray apparatus, with 60 and 70 kV. 254 exams of 113 patients between the ages of 3 to 12 years were evaluated. The skin entrance dose was estimated using TLD-100 thermoluminescent dosemeters. During the examination were also recorded information regarding the time of exposure, radiographic technique used, use of thyroid protectors and lead apron, angle and distance of the cone Locator to the patient's skin. The results showed that the input skin doses ranged from 0.3 mGy to 10mGy. The lead apron was used in 71% of exams while the thyroid shield was only used in 58% of the exams. The exposure times ranged from 0,5s to 1,5s. From the results it can be concluded that the radiological procedures are not optimized and that in some cases the patient dose is high.

  14. Skin entrance dose with and without lead apron in digital panoramic radiography for selected sensitive body regions.

    Science.gov (United States)

    Schulze, Ralf Kurt Willy; Cremers, Catrin; Karle, Heiko; de Las Heras Gala, Hugo

    2017-05-01

    The aim of this study was to compare the dose at skin level at five significant anatomical regions for panoramic radiography devices with and without lead apron by means of a highly sensitive dosimeter. A female RANDO-phantom was exposed in five different digital panoramic radiography systems, and the dose at skin level was assessed tenfold for each measurement region by means of a highly sensitive solid-state-dosimeter. The five measurement regions selected were the thyroid, both female breasts, the gonads, and a central region in the back of the phantom. For each panoramic machine, the measurements were performed in two modes: with and without a commercial lead apron specifically designed for panoramic radiography. Reproducibility of the measurements was expressed by absolute differences and the coefficient of variation. Values between shielded and unshielded doses were pooled for each region and compared by means of the paired Wilcoxon tests (p ≤ 0.05). Reproducibility as represented by the mean CV was 22 ± 52 % (median 2.3 %) with larger variations for small dose values. Doses at skin level ranged between 0.00 μGy at the gonads and 85.39 μGy at the unshielded thyroid (mean ± SD 15 ± 24 μGy). Except for the gonads, the dose in all the other regions was significantly lower (p < 0.001) when a lead apron was applied. Unshielded doses were between 1.02-fold (thyroid) and 112-fold (at the right breast) higher than those with lead apron shielding (mean: 14-fold ± 18-fold). Although the doses were entirely very low, we observed a significant increase in dose in the radiation-sensitive female breast region when no lead apron was used. Future discussions on shielding requirements for panoramic radiography should focus on these differences in the light of the linear non-threshold (LNT) theory which is generally adopted in medical imaging.

  15. Characterization of a cable-free system based on p-type MOSFET detectors for "in vivo" entrance skin dose measurements in interventional radiology.

    Science.gov (United States)

    Falco, Maria Daniela; D'Andrea, Marco; Strigari, Lidia; D'Alessio, Daniela; Quagliani, Francesco; Santoni, Riccardo; Bosco, Alessia Lo

    2012-08-01

    During radiological interventional procedures (RIP) the skin of a patient under examination may undergo a prolonged x-ray exposure, receiving a dose as high as 5 Gy in a single session. This paper describes the use of the OneDose(TM) cable-free system based on p-type MOSFET detectors to determine the entrance skin dose (ESD) at selected points during RIP. At first, some dosimetric characteristics of the detector, such as reproducibility, linearity, and fading, have been investigated using a C-arc as a source of radiation. The reference setting (RS) was: 80 kV energy, 40 cm × 40 cm field of view (FOV), current-time product of 50 mAs and source to skin distance (SSD) of 50 cm. A calibrated PMX III solid state detector was used as the reference detector and Gafchromic(®) films have been used as an independent dosimetric system to test the entire procedure. A calibration factor for the RS and correction factors as functions of tube voltage and FOV size have been determined. Reproducibility ranged from 4% at low doses (around 10 cGy as measured by the reference detector) to about 1% for high doses (around 2 Gy). The system response was found to be linear with respect to both dose measured with the PMX III and tube voltage. The fading test has shown that the maximum deviation from the optimal reading conditions (3 min after a single irradiation) was 9.1% corresponding to four irradiations in one hour read 3 min after the last exposure. The calibration factor in the RS has shown that the system response at the kV energy range is about four times larger than in the MV energy range. A fifth order and fourth order polynomial functions were found to provide correction factors for tube voltage and FOV size, respectively, in measurement settings different than the RS. ESDs measured with the system after applying the proper correction factors agreed within one standard deviation (SD) with the corresponding ESDs measured with the reference detector. The ESDs measured with

  16. Skin entrance dose - thyroid: comparison between three kinds of dental appliances; Dose de entrada na pele - tireóide: comparativo entre três tipos de aparelhos odontológicos

    Energy Technology Data Exchange (ETDEWEB)

    Savi, M.; Viana, E.; Soares, F.A., E-mail: matheus.savi@ifsc.edu.br [Dept. Acadêmico de Saúde e Serviços/CST em Radiologia, Instituto Federal de Santa Catarina, Florianópolis (Brazil)

    2017-07-01

    Patient dosimetry is necessary to determine dosimetric quantities, establish reference levels for radio-diagnosis and assess health risks. Part of the radiation beam of the appliances that penetrates the patient's body is absorbed by tissues and part is spread and its sum is known as the Dose of Entrance into the Skin. The objective of this study is to know and compare the DEP of dental radiology devices in the thyroid gland. Two periapical, panoramic and computerized conical beam tomographs were used in this study at a private dentistry clinic and at the Federal Institute of Santa Catarina. The periapical apparatus produced the highest total dose of radiation, as well as a higher dose rate, followed by CBCT and panoramic.

  17. SED-ED, a workflow editor for computational biology experiments written in SED-ML.

    Science.gov (United States)

    Adams, Richard R

    2012-04-15

    The simulation experiment description markup language (SED-ML) is a new community data standard to encode computational biology experiments in a computer-readable XML format. Its widespread adoption will require the development of software support to work with SED-ML files. Here, we describe a software tool, SED-ED, to view, edit, validate and annotate SED-ML documents while shielding end-users from the underlying XML representation. SED-ED supports modellers who wish to create, understand and further develop a simulation description provided in SED-ML format. SED-ED is available as a standalone Java application, as an Eclipse plug-in and as an SBSI (www.sbsi.ed.ac.uk) plug-in, all under an MIT open-source license. Source code is at https://sed-ed-sedmleditor.googlecode.com/svn. The application itself is available from https://sourceforge.net/projects/jlibsedml/files/SED-ED/.

  18. Entrance surface dose distribution and organ dose assessment for cone-beam computed tomography using measurements and Monte Carlo simulations with voxel phantoms

    Science.gov (United States)

    Baptista, M.; Di Maria, S.; Vieira, S.; Vaz, P.

    2017-11-01

    Cone-Beam Computed Tomography (CBCT) enables high-resolution volumetric scanning of the bone and soft tissue anatomy under investigation at the treatment accelerator. This technique is extensively used in Image Guided Radiation Therapy (IGRT) for pre-treatment verification of patient position and target volume localization. When employed daily and several times per patient, CBCT imaging may lead to high cumulative imaging doses to the healthy tissues surrounding the exposed organs. This work aims at (1) evaluating the dose distribution during a CBCT scan and (2) calculating the organ doses involved in this image guiding procedure for clinically available scanning protocols. Both Monte Carlo (MC) simulations and measurements were performed. To model and simulate the kV imaging system mounted on a linear accelerator (Edge™, Varian Medical Systems) the state-of-the-art MC radiation transport program MCNPX 2.7.0 was used. In order to validate the simulation results, measurements of the Computed Tomography Dose Index (CTDI) were performed, using standard PMMA head and body phantoms, with 150 mm length and a standard pencil ionizing chamber (IC) 100 mm long. Measurements for head and pelvis scanning protocols, usually adopted in clinical environment were acquired, using two acquisition modes (full-fan and half fan). To calculate the organ doses, the implemented MC model of the CBCT scanner together with a male voxel phantom ("Golem") was used. The good agreement between the MCNPX simulations and the CTDIw measurements (differences up to 17%) presented in this work reveals that the CBCT MC model was successfully validated, taking into account the several uncertainties. The adequacy of the computational model to map dose distributions during a CBCT scan is discussed in order to identify ways to reduce the total CBCT imaging dose. The organ dose assessment highlights the need to evaluate the therapeutic and the CBCT imaging doses, in a more balanced approach, and the

  19. SED/Apple Computer, Inc., Partnership Program.

    Science.gov (United States)

    Stoll, Peter F.

    1991-01-01

    In 1990, the New York State Education Department (SED), Apple Computer, Inc., Boards of Cooperative Educational Services (BOCES), and school districts formed a partnership to explore the contribution technology can make to schools based on Apple Computer's Learning Society and SED's Long-Range Plan for Technology in Elementary and Secondary…

  20. Entrance surface dose and image quality: Comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia

    International Nuclear Information System (INIS)

    Hambali, A. S.; Ng, K. H.; Abdullah, B. J. J.; Wang, H. B.; Jamal, N.; Spelic, D. C.; Suleiman, O. H.

    2009-01-01

    This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia. (authors)

  1. Dose on the entrance surface of thyroid, crystalline lens and gonads during the chest X-rays studies; Dosis en la superficie de entrada de tiroides, cristalino y gonadas durante los examenes radiologicos de torax

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez G, R.; Guerra M, J. A.; Pinedo S, A.; Hernandez O, M.; Duran M, H. A.; Salas L, M. A.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98000 Zacatecas (Mexico); Rivera M, T. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, IPN, Av. Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolita, Unidad Iztapalapa, Av. San Rafael Atlixco 186, 09340 Mexico D. F. (Mexico)], e-mail: rgg_df@hotmail.com

    2009-10-15

    There were a measurement series in General Hospital of Fresnillo in X-rays department in areas of X-1 and X-2 ray rooms and in a neonatal intensive care unit 2, the dose was determined on the entrance surface into eyes, thyroid and gonads for patients undergoing to X-rays study of tele chest by thermoluminescent dosimetry. 5 dosemeters were used in each of the scans, found the following dose ranges 20+{sub -} 23 {mu}Gy to 350 +{sub -} 41 {mu}Gy. With results we can conclude that the used procedures and the calibration equipment are adequate. (Author)

  2. Feasibility study of entrance and exit dose measurements at the contra lateral breast with alanine/electron spin resonance dosimetry in volumetric modulated radiotherapy of breast cancer

    Science.gov (United States)

    Wagner, Daniela M.; Hüttenrauch, Petra; Anton, Mathias; von Voigts-Rhetz, Philip; Zink, Klemens; Wolff, Hendrik A.

    2017-07-01

    The Physikalisch-Technische Bundesanstalt has established a secondary standard measurement system for the dose to water, D W, based on alanine/ESR (Anton et al 2013 Phys. Med. Biol. 58 3259-82). The aim of this study was to test the established measurement system for the out-of-field measurements of inpatients with breast cancer. A set of five alanine pellets were affixed to the skin of each patient at the contra lateral breast beginning at the sternum and extending over the mammilla to the distal surface. During 28 fractions with 2.2 Gy per fraction, the accumulated dose was measured in four patients. A cone beam computer tomography (CBCT) scan was generated for setup purposes before every treatment. The reference CT dataset was registered rigidly and deformably to the CBCT dataset for 28 fractions. To take the actual alanine pellet position into account, the dose distribution was calculated for every fraction using the Acuros XB algorithm. The results of the ESR measurements were compared to the calculated doses. The maximum dose measured at the sternum was 19.9 Gy  ±  0.4 Gy, decreasing to 6.8 Gy  ±  0.2 Gy at the mammilla and 4.5 Gy  ±  0.1 Gy at the distal surface of the contra lateral breast. The absolute differences between the calculated and measured doses ranged from  -1.9 Gy to 0.9 Gy. No systematic error could be seen. It was possible to achieve a combined standard uncertainty of 1.63% for D W  =  5 Gy for the measured dose. The alanine/ESR method is feasible for in vivo measurements.

  3. English for common entrance

    CERN Document Server

    Kossuth, Kornel

    2013-01-01

    Succeed in the exam with this revision guide, designed specifically for the brand new Common Entrance English syllabus. It breaks down the content into manageable and straightforward chunks with easy-to-use, step-by-step instructions that should take away the fear of CE and guide you through all aspects of the exam. - Gives you step-by-step guidance on how to recognise various types of comprehension questions and answer them. - Shows you how to write creatively as well as for a purpose for the section B questions. - Reinforces and consolidates learning with tips, guidance and exercises through

  4. The methodology proposed to estimate the absorbed dose at the entrance of the labyrinth in HDR brachytherapy facilities with IR-192

    International Nuclear Information System (INIS)

    Pujades, M. C.; Perez-Calatayud, J.; Ballester, F.

    2012-01-01

    In the absence of procedure for evaluating the design of a brachytherapy (BT) vault with maze from the point of view of radiation protection, usually formalism of external radiation is adapted. The purpose of this study is to adapt the methodology described by the National council on Radiological Protection and Measurements Report 151 (NCRP 151). Structural Shielding Design for megavoltage X-and Gamma-Ray Radiotherapy facilities, for estimating dose at the door in BT and its comparison with the results megavoltage X-and Gamma-Ray Radiotherapy Facilities, for estimating dose at the door in BT and its comparison with the results obtained by the method of Monte Carlo (MC) for a special case of bunker. (Author) 17 refs.

  5. Panchromatic SED modelling of spatially resolved galaxies

    Science.gov (United States)

    Smith, Daniel J. B.; Hayward, Christopher C.

    2018-05-01

    We test the efficacy of the energy-balance spectral energy distribution (SED) fitting code MAGPHYS for recovering the spatially resolved properties of a simulated isolated disc galaxy, for which it was not designed. We perform 226 950 MAGPHYS SED fits to regions between 0.2 and 25 kpc in size across the galaxy's disc, viewed from three different sight-lines, to probe how well MAGPHYS can recover key galaxy properties based on 21 bands of UV-far-infrared model photometry. MAGPHYS yields statistically acceptable fits to >99 per cent of the pixels within the r-band effective radius and between 59 and 77 percent of pixels within 20 kpc of the nucleus. MAGPHYS is able to recover the distribution of stellar mass, star formation rate (SFR), specific SFR, dust luminosity, dust mass, and V-band attenuation reasonably well, especially when the pixel size is ≳ 1 kpc, whereas non-standard outputs (stellar metallicity and mass-weighted age) are recovered less well. Accurate recovery is more challenging in the smallest sub-regions of the disc (pixel scale ≲ 1 kpc), where the energy balance criterion becomes increasingly incorrect. Estimating integrated galaxy properties by summing the recovered pixel values, the true integrated values of all parameters considered except metallicity and age are well recovered at all spatial resolutions, ranging from 0.2 kpc to integrating across the disc, albeit with some evidence for resolution-dependent biases. These results must be considered when attempting to analyse the structure of real galaxies with actual observational data, for which the `ground truth' is unknown.

  6. EARLY ENTRANCE COPRODUCTION PLANT

    Energy Technology Data Exchange (ETDEWEB)

    John S. Abughazaleh; Mushtaq Ahmed; Ashok Anand; John H. Anderson; Charles Benham; Fred D. Brent; Thomas E. Chance; William K. Davis; Raymond F. Drnevich; Larry Hall; Ming He; Stephen A. Lang; David Mintner; Wendy Moore; Jimmy O. Ong; George Potoczniak; Adela G. Sanchez; Charles H. Schrader; Lalit S. Shah; Kalapi D. Sheth; Phil J. Shires; Rae Song

    2001-05-17

    The overall objective of this project is the three-phase development of an Early Entrance Coproduction Plant (EECP) that produces at least one product from at least two of the following three categories: Electric power (or heat); Fuels; and Chemicals. The objective is to have these products produced by technologies capable of using synthesis gas derived from coal and/or some other carbonaceous feedstock, such as petroleum coke. The objective of Phase I was to determine the feasibility and define the concept for the EECP located at a specific site and to develop a Research, Development, and Testing (RD and T) Plan for implementation in Phase II. This objective has now been accomplished. A specific site, Motiva Refinery in Port Arthur, Texas, has been selected as the location best suited for the EECP. The accomplishments of Phase I are discussed in detail in this Phase I Concept Report. A RD and T Plan and a preliminary project financing plan have been developed and are submitted separately from this report.

  7. EARLY ENTRANCE COPRODUCTION PLANT

    International Nuclear Information System (INIS)

    William K. Davis

    2001-01-01

    The overall objective of this project is the three phase development of an Early Entrance Coproduction Plant (EECP) which produces at least one product from at least two of the following three categories: (1) electric power (or heat), (2) fuels, and (3) chemicals. The objective is to have these products produced by technologies capable of using synthesis gas derived from coal and/or other carbonaceous feedstocks. The objective of Phase I is to determine the feasibility and define the concept for the EECP located at a specific site; develop a Research, Development, and Testing (RD and T) Plan for implementation in Phase II; and prepare a Preliminary Project Financing Plan. The objective of Phase II is to implement the work as outlined in the Phase I RD and T Plan to enhance the development and commercial acceptance of coproduction technology that produces high-value products, particularly those that are critical to our domestic fuel and power requirements. The project will resolve critical knowledge and technology gaps on the integration of gasification and downstream processing to coproduce some combination of power, fuels, and chemicals from coal and/or other carbonaceous feedstocks. The objective of Phase III is to develop an engineering design package and a financing plan for an EECP located at a specific site. The project's intended result is to provide the necessary technical, economic, and environmental information needed by industry to move the EECP forward to detailed design, construction, and operation

  8. Verification of Entrance Dose Measurements with ...

    African Journals Online (AJOL)

    Department of Radiotherapy, Eko Hospitals, Ekocorp Plc, Ikeja, 1Department of Radiation Biology, ... as a veritable means of quality control in conventional radiotherapy procedures was determined ... equipment and procedures for assessment, planning, and ..... an in vivo dosimetry program during breast cancer irradiation.

  9. SED Modeling of 20 Massive Young Stellar Objects

    Science.gov (United States)

    Tanti, Kamal Kumar

    In this paper, we present the spectral energy distributions (SEDs) modeling of twenty massive young stellar objects (MYSOs) and subsequently estimated different physical and structural/geometrical parameters for each of the twenty central YSO outflow candidates, along with their associated circumstellar disks and infalling envelopes. The SEDs for each of the MYSOs been reconstructed by using 2MASS, MSX, IRAS, IRAC & MIPS, SCUBA, WISE, SPIRE and IRAM data, with the help of a SED Fitting Tool, that uses a grid of 2D radiative transfer models. Using the detailed analysis of SEDs and subsequent estimation of physical and geometrical parameters for the central YSO sources along with its circumstellar disks and envelopes, the cumulative distribution of the stellar, disk and envelope parameters can be analyzed. This leads to a better understanding of massive star formation processes in their respective star forming regions in different molecular clouds.

  10. EARLY ENTRANCE COPRODUCTION PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Fred D. Brent; Lalit Shah; Earl Berry; Charles H. Schrader; John Anderson; Ming He; James F. Stevens; Centha A. Davis; Michael Henley; Jerome Mayer; Harry Tsang; Jimell Erwin; Jennifer Adams; Michael Tillman; Chris Taylor; Marjan J. Roos; Robert F. Earhart

    2004-01-27

    The overall objective of this project is the three phase development of an Early Entrance Coproduction Plant (EECP) which uses petroleum coke to produce at least one product from at least two of the following three categories: (1) electric power (or heat), (2) fuels, and (3) chemicals using ChevronTexaco's proprietary gasification technology. The objective of Phase I is to determine the feasibility and define the concept for the EECP located at a specific site; develop a Research, Development, and Testing (RD&T) Plan to mitigate technical risks and barriers; and prepare a Preliminary Project Financing Plan. The objective of Phase II is to implement the work as outlined in the Phase I RD&T Plan to enhance the development and commercial acceptance of coproduction technology. The objective of Phase III is to develop an engineering design package and a financing and testing plan for an EECP located at a specific site. The project's intended result is to provide the necessary technical, economic, and environmental information needed by industry to move the EECP forward to detailed design, construction, and operation. The partners in this project are Texaco Energy Systems LLC or TES (a subsidiary of ChevronTexaco), General Electric (GE), Praxair, and Kellogg Brown & Root (KBR) in addition to the U.S. Department of Energy (DOE). TES is providing gasification technology and Fischer-Tropsch (F-T) technology developed by Rentech, GE is providing combustion turbine technology, Praxair is providing air separation technology, and KBR is providing engineering. Each of the EECP subsystems was assessed for technical risks and barriers. A plan was developed to mitigate the identified risks (Phase II RD&T Plan, October 2000). The potential technical and economic risks to the EECP from Task 2.5 can be mitigated by demonstrating that the end-use products derived from the upgrading of the F-T synthesis total liquid product can meet or exceed current specifications for the

  11. Evaluation of skin entrance radiation dose in pediatric patients undergoing chest X-rays exams; Avaliacao da dose de entrada na pele em pacientes pediatricos submetidos a exames radiograficos do torax

    Energy Technology Data Exchange (ETDEWEB)

    Gabardo, Farly Piantini

    2016-07-01

    The aim of this work was to estimate the incident air kerma of lateral (LAT) and anterior-posterior (AP) together with posterior-anterior (PA) projection chest X-ray exams in one of the largest pediatric hospitals in Brazil. Dosimetric results are accompanied with the detailed analysis of patient characteristics and radiographer strategy. The exams of 225 (119 male and 106 female) patients were studied and 389 X-ray exams (200 AP/PA projections and 189 LAT projections) of pediatric patients were acquired. Patient thickness can be restored from age, height or weight with the uncertainty of ∼20-30%. Very slight correlation between the patient dose and thickness was observed with the difference in dose for patients of the same thickness reaching 4 times. By standardization of radiological protocols, it should be possible to keep dose within the intervals 50-100 μGy for LAT projection and 40-80 μGy for AP/PA projection. The dose values are lower than those recommended by major European guidelines to good practice. (author)

  12. EARLY ENTRANCE COPRODUCTION PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Fred D. Brent; Lalit Shah; Earl Berry; Charles H. Schrader; John Anderson; J. Erwin; Matthew G. Banks; Terry L. Ullman

    2004-01-12

    The overall objective of this project is the three phase development of an Early Entrance Coproduction Plant (EECP) which uses petroleum coke to produce at least one product from at least two of the following three categories: (1) electric power (or heat), (2) fuels, and (3) chemicals using ChevronTexaco's proprietary gasification technology. The objective of Phase I is to determine the feasibility and define the concept for the EECP located at a specific site; develop a Research, Development, and Testing (RD&T) Plan to mitigate technical risks and barriers; and prepare a Preliminary Project Financing Plan. The objective of Phase II is to implement the work as outlined in the Phase I RD&T Plan to enhance the development and commercial acceptance of coproduction technology. The objective of Phase III is to develop an engineering design package and a financing and testing plan for an EECP located at a specific site. The project's intended result is to provide the necessary technical, economic, and environmental information needed by industry to move the EECP forward to detailed design, construction, and operation. The partners in this project are Texaco Energy Systems LLC or TES (a subsidiary of ChevronTexaco), General Electric (GE), Praxair, and Kellogg Brown & Root (KBR) in addition to the U.S. Department of Energy (DOE). TES is providing gasification technology and Fischer-Tropsch (F-T) technology developed by Rentech, GE is providing combustion turbine technology, Praxair is providing air separation technology, and KBR is providing engineering. Each of the EECP subsystems was assessed for technical risks and barriers. A plan was developed to mitigate the identified risks (Phase II RD&T Plan, October 2000). Phase II RD&T Task 2.6 identified as potential technical risks to the EECP the fuel/engine performance and emissions of the F-T diesel fuel products. Hydrotreating the neat F-T diesel product reduces potentially reactive olefins, oxygenates, and acids

  13. Analysis of entrance skin radiation dose in mammography equipment in Rio Grande do Sul state (Ijui municipality and surroundings) and Rio de Janeiro (metropolitan area); Analise de dose de entrada na pele em mamografos, no Estado do Rio Grande do Sul (Municipio de Ijui e cercanias) e Rio de Janeiro (area metropolitana)

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Geovane Silva; Padilha Filho, Lucas Gomes, E-mail: geovane.araujo@ftesm.edu.br, E-mail: lucaspadilhaemec@gmail.com [Universidade Estacio de Sa (UNESA), Rio de Janeiro, RJ (Brazil); Sousa, Carlos Henrique Simoes de, E-mail: chenriques2@gmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Feldmann, Gerson; Albrecht, Marcos R.A., E-mail: gersonpraxis@gmail.com, E-mail: marcosboom@yahoo.com.br [PRAXIS Protecao Radiologica, Ijui, RS (Brazil); Souza, Sergio Augusto Lopes de, E-mail: sergioalsouza@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil)

    2016-07-01

    Mammography is the technique widely used to the early detection of breast cancer, despite of not being a consensus the ideal age to initiate the radiologic examinations, it is recommended that women with the age of forty realize the examinations periodically. With the objective to analyze the entrance skin dose (ESD) in different mammography equipment, Were analyzed in the Estate of Rio Grande do Sul (Ijui City and neighborhoods) and in Rio de Janeiro (metropolitan area) 24 mammography equipment. Among them included in the study, just one presented ESD higher than the established limit of ANVISA. It was observed in the mammography equipment of Ijui and neighborhoods high levels of mAs to achieve the values of ESD next to the limit. (author)

  14. Introduction to the Buildings Sector Module of SEDS

    Energy Technology Data Exchange (ETDEWEB)

    DeForest, Nicholas; Bonnet, Florence; Stadler, Michael; Marnay, Chris

    2010-12-31

    SEDS is a stochastic engineering-economics model that forecasts economy-wide energy consumption in the U.S. to 2050. It is the product of multi-laboratory collaboration among the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), Argonne National Laboratory (ANL), Lawrence Berkeley National Laboratory (LBNL), and Lumina Decision Systems. Among national energy models, SEDS is unique, as it is the only model written to explicitly incorporate uncertainty in its inputs and outputs. The primary purpose of SEDS is to estimate the impact of various US Department of Energy (DOE)R&D and policy programs on the performance and subsequent adoption rates of technologies relating to every energy consuming sector of the economy (shown below). It has previously been used to assist DOE in complying with the Government Performance and Results Act of 1993 (GPRA). The focus of LBNL research has been exclusively on develop the buildings model (SBEAM), which is capable of running as a stand-alone forecasting model, or as a part of SEDS as a whole. The full version of SEDS, containing all sectors and interaction is also called the 'integrated' version and is managed by NREL. Forecasts from SEDS are often compared to those coming from National Energy Modeling System (NEMS). The intention of this document is to present new users and developers with a general description of the purpose, functionality and structure of the buildings module within the Stochastic Energy Deployment System (SEDS). The Buildings module, which is capable of running as a standalone model, is also called the Stochastic Buildings Energy and Adoption Model (SBEAM). This document will focus exclusively on SBEAM and its interaction with other major sector modules present within SEDS. The methodologies and major assumptions employed in SBEAM will also be discussed. The organization of this report will parallel the organization of the model itself, being divided into major

  15. Temporary closure of Entrance A

    CERN Document Server

    2007-01-01

    Entrance A to the CERN site will be temporarily closed to incoming traffic between 1.30 p.m. and 6.00 p.m. on Tuesday 30 January in order to allow the information signs to be changed. Thank you for your understanding. TS/CSE Group

  16. A comparison of approaches in fitting continuum SEDs

    International Nuclear Information System (INIS)

    Liu Yao; Wang Hong-Chi; Madlener David; Wolf Sebastian

    2013-01-01

    We present a detailed comparison of two approaches, the use of a pre-calculated database and simulated annealing (SA), for fitting the continuum spectral energy distribution (SED) of astrophysical objects whose appearance is dominated by surrounding dust. While pre-calculated databases are commonly used to model SED data, only a few studies to date employed SA due to its unclear accuracy and convergence time for this specific problem. From a methodological point of view, different approaches lead to different fitting quality, demand on computational resources and calculation time. We compare the fitting quality and computational costs of these two approaches for the task of SED fitting to provide a guide to the practitioner to find a compromise between desired accuracy and available resources. To reduce uncertainties inherent to real datasets, we introduce a reference model resembling a typical circumstellar system with 10 free parameters. We derive the SED of the reference model with our code MC3 D at 78 logarithmically distributed wavelengths in the range [0.3 μm, 1.3 mm] and use this setup to simulate SEDs for the database and SA. Our result directly demonstrates the applicability of SA in the field of SED modeling, since the algorithm regularly finds better solutions to the optimization problem than a pre-calculated database. As both methods have advantages and shortcomings, a hybrid approach is preferable. While the database provides an approximate fit and overall probability distributions for all parameters deduced using Bayesian analysis, SA can be used to improve upon the results returned by the model grid.

  17. Entrance

    Science.gov (United States)

    Kallan, Richard A.

    1975-01-01

    Provides a brief sketch of the essential characteristics of new journalism, offers a rationale for calling it "new," and differentiates the new nonfiction from the broader concept of new journalism. See CS 702 359 for availability information.(RB)

  18. Science for common entrance physics : answers

    CERN Document Server

    Pickering, W R

    2015-01-01

    This book contains answers to all exercises featured in the accompanying textbook Science for Common Entrance: Physics , which covers every Level 1 and 2 topic in the ISEB 13+ Physics Common Entrance exam syllabus. - Clean, clear layout for easy marking. - Includes examples of high-scoring answers with diagrams and workings. - Suitable for ISEB 13+ Mathematics Common Entrance exams taken from Autumn 2017 onwards. Also available to purchase from the Galore Park website www.galorepark.co.uk :. - Science for Common Entrance: Physics. - Science for Common Entrance: Biology. - Science for Common En

  19. Utility service entrance in boreholes

    International Nuclear Information System (INIS)

    1987-08-01

    This study evaluates alternatives for utility service entrances to the repository. We determined the requirements for a repository utility supply. These requirements were defined as safety, maintainability, flexibility, reliability, cost efficiency, voltage regulation, and simplicity of operation. The study showed that repository shafts can best satisfy all requirements for location of the utility supply without the use of borehole penetrations into the repository. It is recommended that the shafts be utilized for utility distribution to the repository, and that the current NWTS program position to minimize the number of boreholes penetrating the repository horizon be maintained. 42 refs., 2 figs., 3 tabs

  20. Correlation and uncertainties evaluation in backscattering of entrance surface air kerma measurements

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, G.J.; Sousa, C.H.S.; Peixoto, J.G.P., E-mail: gt@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The air kerma measurement is important to verify the applied doses in radiodiagnostic. The literature determines some methods to measure the entrance surface air kerma or entrance surface dose but some of this methods may increase the measurement with the backscattering. Were done setups of measurements to do correlations between them. The expanded uncertainty exceeded 5% for measurements with backscattering, reaching 8.36%, while in situations where the backscattering was avoided, the uncertainty was 3.43%. (author)

  1. Influência da dependência energética de dosímetros termoluminescentes na medida da dose na entrada da pele em procedimentos radiográficos Influence of thermoluminescent dosimeters energy dependence on the measurement of entrance skin dose in radiographic procedures

    Directory of Open Access Journals (Sweden)

    Mércia Liane de Oliveira

    2010-04-01

    Full Text Available OBJETIVO: O objetivo do presente trabalho foi avaliar a influência da dependência energética de materiais termoluminescentes na determinação da dose na entrada da pele de pacientes submetidos a exames radiográficos (radiologia geral, mamografia e radiologia odontológica. MATERIAIS E MÉTODOS: Três diferentes materiais termoluminescentes foram utilizados: LiF:Mg,Ti, LiF:Mg,Cu,P e CaSO4:Dy. Estes materiais foram expostos a fontes padronizadas de radiação X e gama, e a feixes clínicos de raios X. RESULTADOS: As curvas de calibração e de dependência energética foram obtidas. Todos os materiais apresentaram resposta linear em função do kerma no ar. Com relação à dependência energética, as amostras de CaSO4:Dy e LiF:Mg,Ti mostraram maior variação da resposta termoluminescente em função da energia efetiva do feixe de radiação. CONCLUSÃO: Os materiais testados mostraram desempenho adequado para a detecção da radiação X em feixes padronizados e clínicos. Embora as amostras de CaSO4:Dy e LiF:Mg,Ti apresentem dependência energética significativa no intervalo de energia considerado, este materiais podem ser utilizados para medição da dose de entrada na pele se fatores de correção apropriados forem utilizados.OBJECTIVE: This study was aimed at evaluating the influence of the energy dependence of thermoluminescent materials on the determination of entrance skin dose in patients submitted to conventional radiographic studies (general radiology, mammography and dental radiology. MATERIALS AND METHODS: Three different thermoluminescent materials were utilized: LiF:Mg,Ti, LiF:Mg,Cu,P and CaSO4:Dy. These materials were exposed to standardized sources of X and gamma radiation and clinical X-ray beams. RESULTS: Calibration and energy dependence curves were obtained. All the materials showed a linear response as a function of the air kerma. As far as energy dependence is concerned, the CaSO4:Dy and LiF:Mg,Ti samples showed the

  2. Constrain the SED Type of Unidentified Fermi Objects

    Directory of Open Access Journals (Sweden)

    An-Li Tsai

    2013-09-01

    Full Text Available 2FGL J1823.8+4312 and 2FGL J1304.1-2415 are two unidentified Fermi objects which are associated with cluster of galaxies. In order to exam the possibility of cluster of galaxies as gamma-ray emitters, we search for counterpart of these two unidentified Fermi objects in other wavebands. However, we find other candidate to be more likely the counterpart of the unidentified Fermi object for both sources. We compare their light curves and SEDs in order to identify their source types. However, data at millimeter and sub-millimeter wavebands, which is important for us to constrain the SED at synchrotron peak, is lacking of measurement. Therefore, we proposed to SMA observation for these two sources. We have got data and are doing further analysis.

  3. GOSSIP, a New VO Compliant Tool for SED Fitting

    Science.gov (United States)

    Franzetti, P.; Scodeggio, M.; Garilli, B.; Fumana, M.; Paioro, L.

    2008-08-01

    We present GOSSIP (Galaxy Observed-Simulated SED Interactive Program), a new tool developed to perform SED fitting in a simple, user friendly and efficient way. GOSSIP automatically builds-up the observed SED of an object (or a large sample of objects) combining magnitudes in different bands and eventually a spectrum; then it performs a χ^2 minimization fitting procedure versus a set of synthetic models. The fitting results are used to estimate a number of physical parameters like the Star Formation History, absolute magnitudes, stellar mass and their Probability Distribution Functions. User defined models can be used, but GOSSIP is also able to load models produced by the most commonly used synthesis population codes. GOSSIP can be used interactively with other visualization tools using the PLASTIC protocol for communications. Moreover, since it has been developed with large data sets applications in mind, it will be extended to operate within the Virtual Observatory framework. GOSSIP is distributed to the astronomical community from the PANDORA group web site (http://cosmos.iasf-milano.inaf.it/pandora/gossip.html).

  4. From SED HI concept to Pleiades FM detection unit measurements

    Science.gov (United States)

    Renard, Christophe; Dantes, Didier; Neveu, Claude; Lamard, Jean-Luc; Oudinot, Matthieu; Materne, Alex

    2017-11-01

    The first flight model PLEIADES high resolution instrument under Thales Alenia Space development, on behalf of CNES, is currently in integration and test phases. Based on the SED HI detection unit concept, PLEIADES detection unit has been fully qualified before the integration at telescope level. The main radiometric performances have been measured on engineering and first flight models. This paper presents the results of performances obtained on the both models. After a recall of the SED HI concept, the design and performances of the main elements (charge coupled detectors, focal plane and video processing unit), detection unit radiometric performances are presented and compared to the instrument specifications for the panchromatic and multispectral bands. The performances treated are the following: - video signal characteristics, - dark signal level and dark signal non uniformity, - photo-response non uniformity, - non linearity and differential non linearity, - temporal and spatial noises regarding system definitions PLEIADES detection unit allows tuning of different functions: reference and sampling time positioning, anti-blooming level, gain value, TDI line number. These parameters are presented with their associated criteria of optimisation to achieve system radiometric performances and their sensitivities on radiometric performances. All the results of the measurements performed by Thales Alenia Space on the PLEIADES detection units demonstrate the high potential of the SED HI concept for Earth high resolution observation system allowing optimised performances at instrument and satellite levels.

  5. The broad-band SEDs of four `hypervariable' AGN

    Science.gov (United States)

    Collinson, James S.; Ward, Martin J.; Lawrence, Andy; Bruce, Alastair; MacLeod, Chelsea L.; Elvis, Martin; Gezari, Suvi; Marshall, Philip J.; Done, Chris

    2018-03-01

    We present an optical-to-X-ray spectral analysis of four `hypervariable' AGN (HVAs) discovered by comparing Pan-STARRS data to that from the Sloan Digital Sky Survey over a 10 yr baseline (Lawrence et al.). There is some evidence that these objects are X-ray loud for their corresponding UV luminosities, but given that we measured them in a historic high state, it is not clear whether to take the high state or low state as typical of the properties of these HVAs. We estimate black hole masses based on Mg II and H α emission line profiles, and either the high- or low-state luminosities, finding mass ranges log (MBH/M⊙) = 8.2-8.8 and log (MBH/M⊙) = 7.9-8.3, respectively. We then fit energy-conserving models to the spectral energy distributions (SEDs), obtaining strong constraints on the bolometric luminosity and αOX. We compare the SED properties with a larger, X-ray selected AGN sample for both of these scenarios, and observe distinct groupings in spectral shape versus luminosity parameter space. In general, the SED properties are closer to normal if we assume that the low state is representative. This supports the idea that the large slow outbursts may be due to extrinsic effects (for example microlensing) as opposed to accretion rate changes, but a larger sample of HVAs is needed to be confident of this conclusion.

  6. SedMob: A mobile application for creating sedimentary logs in the field

    Science.gov (United States)

    Wolniewicz, Pawel

    2014-05-01

    SedMob is an open-source, mobile software package for creating sedimentary logs, targeted for use in tablets and smartphones. The user can create an unlimited number of logs, save data from each bed in the log as well as export and synchronize the data with a remote server. SedMob is designed as a mobile interface to SedLog: a free multiplatform package for drawing graphic logs that runs on PC computers. Data entered into SedMob are saved in the CSV file format, fully compatible with SedLog.

  7. Evaluation of entrance surface air kerma in pediatric chest radiography

    International Nuclear Information System (INIS)

    Porto, L.; Lunelli, N.; Paschuk, S.; Oliveira, A.; Ferreira, J.L.; Schelin, H.; Miguel, C.; Denyak, V.; Kmiecik, C.; Tilly, J.; Khoury, H.

    2014-01-01

    The objective of this study was to evaluate the entrance surface air kerma in pediatric chest radiography. An evaluation of 301 radiographical examinations in anterior–posterior (AP) and posterior–anterior (PA) (166 examinations) and lateral (LAT) (135 examinations) projections was performed. The analyses were performed on patients grouped by age; the groups included ages 0–1 y, 1–5 y, 5–10 y, and 10–15 y. The entrance surface air kerma was determined with DoseCal software (Radiological Protection Center of Saint George's Hospital, London) and thermoluminescent dosimeters. Two different exposure techniques were compared. The doses received by patients who had undergone LAT examinations were 40% higher, on average, those in AP/PA examinations because of the difference in tube voltage. A large high-dose “tail” was observed for children up to 5 y old. An increase in tube potential and corresponding decrease in current lead to a significant dose reduction. The difference between the average dose values for different age ranges was not practically observed, implying that the exposure techniques are still not optimal. Exposure doses received using the higher tube voltage and lower current-time product correspond to the international diagnostic reference levels. - Highlights: • The entrance surface air kerma of chest X-ray examinations in pediatric patients was estimated. • The data were analyzed for patients aged up to 15 y, stratified by age. • The doses of LAT examinations were 40% higher than of AP/PA because of kV used. • An increase in kV with a decrease in mAs leads to significant dose reduction

  8. Mathematics for common entrance three (extension) answers

    CERN Document Server

    Alexander, Serena

    2015-01-01

    This book contains answers to all exercises featured in the accompanying textbook Mathematics for Common Entrance Three (Extension) , which provides essential preparation for Level 3 of the ISEB 13+ Mathematics exam, as well as for CASE and other scholarship exams. - Clean, clear layout for easy marking. - Includes examples of high-scoring answers with diagrams and workings. Also available to purchase from the Galore Park website www.galorepark.co.uk :. - Mathematics for Common Entrance Three (Extension). - Mathematics for Common Entrance One. - Mathematics for Common Entrance One Answers. - M

  9. Energy saving in tunnel entrance lighting.

    NARCIS (Netherlands)

    Schreuder, D.A. & Swart, L.

    1993-01-01

    Tunnel entrances may present themselves during the day as a "black hole" in which no details can be perceived. In order to ensure safe and comfortable driving at high speeds, the entrance zone must be lit to a high luminance level. Modern tunnel lighting technology is focused on two aspects:

  10. Evaluation of entrance surface air kerma in pediatric chest radiography

    Science.gov (United States)

    Porto, L.; Lunelli, N.; Paschuk, S.; Oliveira, A.; Ferreira, J. L.; Schelin, H.; Miguel, C.; Denyak, V.; Kmiecik, C.; Tilly, J.; Khoury, H.

    2014-11-01

    The objective of this study was to evaluate the entrance surface air kerma in pediatric chest radiography. An evaluation of 301 radiographical examinations in anterior-posterior (AP) and posterior-anterior (PA) (166 examinations) and lateral (LAT) (135 examinations) projections was performed. The analyses were performed on patients grouped by age; the groups included ages 0-1 y, 1-5 y, 5-10 y, and 10-15 y. The entrance surface air kerma was determined with DoseCal software (Radiological Protection Center of Saint George's Hospital, London) and thermoluminescent dosimeters. Two different exposure techniques were compared. The doses received by patients who had undergone LAT examinations were 40% higher, on average, those in AP/PA examinations because of the difference in tube voltage. A large high-dose “tail” was observed for children up to 5 y old. An increase in tube potential and corresponding decrease in current lead to a significant dose reduction. The difference between the average dose values for different age ranges was not practically observed, implying that the exposure techniques are still not optimal. Exposure doses received using the higher tube voltage and lower current-time product correspond to the international diagnostic reference levels.

  11. Candidate cave entrances on Mars

    Science.gov (United States)

    Cushing, Glen E.

    2012-01-01

    This paper presents newly discovered candidate cave entrances into Martian near-surface lava tubes, volcano-tectonic fracture systems, and pit craters and describes their characteristics and exploration possibilities. These candidates are all collapse features that occur either intermittently along laterally continuous trench-like depressions or in the floors of sheer-walled atypical pit craters. As viewed from orbit, locations of most candidates are visibly consistent with known terrestrial features such as tube-fed lava flows, volcano-tectonic fractures, and pit craters, each of which forms by mechanisms that can produce caves. Although we cannot determine subsurface extents of the Martian features discussed here, some may continue unimpeded for many kilometers if terrestrial examples are indeed analogous. The features presented here were identified in images acquired by the Mars Odyssey's Thermal Emission Imaging System visible-wavelength camera, and by the Mars Reconnaissance Orbiter's Context Camera. Select candidates have since been targeted by the High-Resolution Imaging Science Experiment. Martian caves are promising potential sites for future human habitation and astrobiology investigations; understanding their characteristics is critical for long-term mission planning and for developing the necessary exploration technologies.

  12. SED-ML web tools: generate, modify and export standard-compliant simulation studies.

    Science.gov (United States)

    Bergmann, Frank T; Nickerson, David; Waltemath, Dagmar; Scharm, Martin

    2017-04-15

    The Simulation Experiment Description Markup Language (SED-ML) is a standardized format for exchanging simulation studies independently of software tools. We present the SED-ML Web Tools, an online application for creating, editing, simulating and validating SED-ML documents. The Web Tools implement all current SED-ML specifications and, thus, support complex modifications and co-simulation of models in SBML and CellML formats. Ultimately, the Web Tools lower the bar on working with SED-ML documents and help users create valid simulation descriptions. http://sysbioapps.dyndns.org/SED-ML_Web_Tools/ . fbergman@caltech.edu . © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  13. Case report 512: Spondyloenchondrodysplasia (SED) in two siblings

    Energy Technology Data Exchange (ETDEWEB)

    Ziv, N.; Grunebaum, M.; Kornreich, L.; Mimouni, M.

    1989-01-01

    A pair of siblings are presented with the diagnosis of spondyloenchondrodysplasia (SED) as a disorder in which the chondrocytes in the various growth plates of the long bones and in certain primary ossification centers (vertebral body) fail to mature. Typical features of enchondromatosis are noted. In addition, the spine shows platyspondyly and vertical radiolucent linear clefts just adjacent to the posterior margins of the vertebral bodies. A 'bubbly' appearance is noted in the posterior aspects of the vertebral bodies with irregular sclerotic end plates and a tongue-like configuration of their anterior borders. All laboratory data were normal. The two children may be compared with Schorr's two children reported in 1976 with similar findings. Some degree of dwarfism exists in the children. The tabular summary of the case reported in this article and the two cases of Schorr are appended.

  14. Case report 512: Spondyloenchondrodysplasia (SED) in two siblings

    International Nuclear Information System (INIS)

    Ziv, N.; Grunebaum, M.; Kornreich, L.; Mimouni, M.; Tel Aviv Univ.

    1989-01-01

    A pair of siblings are presented with the diagnosis of spondyloenchondrodysplasia (SED) as a disorder in which the chondrocytes in the various growth plates of the long bones and in certain primary ossification centers (vertebral body) fail to mature. Typical features of enchondromatosis are noted. In addition, the spine shows platyspondyly and vertical radiolucent linear clefts just adjacent to the posterior margins of the vertebral bodies. A 'bubbly' appearance is noted in the posterior aspects of the vertebral bodies with irregular sclerotic end plates and a tongue-like configuration of their anterior borders. All laboratory data were normal. The two children may be compared with Schorr's two children reported in 1976 with similar findings. Some degree of dwarfism exists in the children. The tabular summary of the case reported in this article and the two cases of Schorr are appended. (orig.)

  15. SED16 autonomous star tracker night sky testing

    Science.gov (United States)

    Foisneau, Thierry; Piriou, Véronique; Perrimon, Nicolas; Jacob, Philippe; Blarre, Ludovic; Vilaire, Didier

    2017-11-01

    The SED16 is an autonomous multi-missions star tracker which delivers three axis satellite attitude in an inertial reference frame and the satellite angular velocity with no prior information. The qualification process of this star sensor includes five validation steps using optical star simulator, digitized image simulator and a night sky tests setup. The night sky testing was the final step of the qualification process during which all the functions of the star tracker were used in almost nominal conditions : Autonomous Acquisition of the attitude, Autonomous Tracking of ten stars. These tests were performed in Calern in the premises of the OCA (Observatoire de la Cote d'Azur). The test set-up and the test results are described after a brief review of the sensor main characteristics and qualification process.

  16. How does slope form affect erosion in CATFLOW-SED?

    Science.gov (United States)

    Gabelmann, Petra; Wienhöfer, Jan; Zehe, Erwin

    2016-04-01

    Erosion is a severe environmental problem in agro-ecosystems with highly erodible loess soils. It is controlled by various factors, e.g. rainfall intensity, initial wetness conditions, soil type, land use and tillage practice. Furthermore slope form and gradient have been shown to influence erosion amounts to a large extent. Within the last fifty years, various erosion models have been developed to describe the erosion process, estimate erosion amounts and identify erosion-prone areas. These models differ in terms of complexity, the processes which are considered, and the data required for model calibration and they can be categorised into empirical or statistical, conceptual, and physically-based models. CATFLOW-SED is a process-based hydrology and erosion model that can operate on catchment and hillslope scales. Soil water dynamics are described by the Richards equation including effective approaches for preferential flow. Evapotranspiration is simulated using an approach based on the Penman-Monteith equation. The model simulates overland flow using the diffusion wave equation. Soil detachment is related to the attacking forces of rainfall and overland flow, and the erosion resistance of soil. Sediment transport capacity and sediment deposition are related to overland flow velocity using the equation of Engelund and Hansen and the sinking velocity of grain sizes respectively. We performed a study to analyse the erosion process on different virtual hillslopes, with varying slope gradient and slope form, using the CATFLOW-SED model. We explored the role of landform on erosion and sedimentation, particularly we look for forms that either maximise or minimise erosion. Results indicate the importance to performing the process implementation within physically meaningful limits and choose appropriate model parameters respectively.

  17. Opening the Floodgates? The Social Maladjustment Exclusion and State SED Prevalence Rates.

    Science.gov (United States)

    Skiba, Russell; And Others

    1994-01-01

    Surveyed state special education directors in 50 states and District of Columbia regarding social maladjustment exclusionary clause in federal definition of serious emotional disturbance (SED). Thirty-four states included social maladjustment clause or some form of exclusion in SED definition. Found no significant relationship between presence of…

  18. SIMULTANEOUS ESTIMATION OF PHOTOMETRIC REDSHIFTS AND SED PARAMETERS: IMPROVED TECHNIQUES AND A REALISTIC ERROR BUDGET

    International Nuclear Information System (INIS)

    Acquaviva, Viviana; Raichoor, Anand; Gawiser, Eric

    2015-01-01

    We seek to improve the accuracy of joint galaxy photometric redshift estimation and spectral energy distribution (SED) fitting. By simulating different sources of uncorrected systematic errors, we demonstrate that if the uncertainties in the photometric redshifts are estimated correctly, so are those on the other SED fitting parameters, such as stellar mass, stellar age, and dust reddening. Furthermore, we find that if the redshift uncertainties are over(under)-estimated, the uncertainties in SED parameters tend to be over(under)-estimated by similar amounts. These results hold even in the presence of severe systematics and provide, for the first time, a mechanism to validate the uncertainties on these parameters via comparison with spectroscopic redshifts. We propose a new technique (annealing) to re-calibrate the joint uncertainties in the photo-z and SED fitting parameters without compromising the performance of the SED fitting + photo-z estimation. This procedure provides a consistent estimation of the multi-dimensional probability distribution function in SED fitting + z parameter space, including all correlations. While the performance of joint SED fitting and photo-z estimation might be hindered by template incompleteness, we demonstrate that the latter is “flagged” by a large fraction of outliers in redshift, and that significant improvements can be achieved by using flexible stellar populations synthesis models and more realistic star formation histories. In all cases, we find that the median stellar age is better recovered than the time elapsed from the onset of star formation. Finally, we show that using a photometric redshift code such as EAZY to obtain redshift probability distributions that are then used as priors for SED fitting codes leads to only a modest bias in the SED fitting parameters and is thus a viable alternative to the simultaneous estimation of SED parameters and photometric redshifts

  19. Entrance C - Meyrin site: new access conditions

    CERN Multimedia

    2013-01-01

    Entrance C on the Meyrin site, which drivers of motorised vehicles can use Mondays to Fridays from 7 a.m. to 9 a.m. and from 5 p.m. to 7 p.m., has been altered to include a turnstile to allow cyclists and pedestrians to use their access card to get in and out of the site from 6 a.m. until 10 p.m.   The following video illustrates how to use the new turnstile: A new type of entrance gate fitted with a number plate reader similar to that installed at the entrance to the Prévessin site should, once fully tested, allow drivers of motorised vehicles to access the site. For the time being, the conditions of use of Entrance C remain unchanged. Further information on the entry into force of new arrangements will be issued in due course. For further information about CERN entrances: CERN opening hours CERN control access GS Department

  20. Entrances and entrance halls of residential buildings in Belgrade: 1918-1941

    Directory of Open Access Journals (Sweden)

    Putnik Vladana

    2015-01-01

    Full Text Available Between the two world wars Belgrade saw a surge in housing construction, including many rental apartment buildings, so-called 'luxury city palaces'. In addition to richly decorated street façades in the style of academism, eclecticism and Art Deco, architects paid much attention to the design of entrances and entrance halls. The entrance frequently was the main element of the façade even in buildings in a moderate modernist style. Since this aspect of architectural design is scantily documented, this paper seeks to identify its main trends in the 1920s and 1930s and to establish a typology of entrances and entrance halls of residential buildings. It also outlines the parameters and social circumstances that played a role in giving special attention to this element of residential buildings, and examines whether Belgrade architects pursued a sort of total design inspired by European models.

  1. SED fitting with MCMC: methodology and application to large galaxy surveys

    OpenAIRE

    Acquaviva, Viviana; Gawiser, Eric; Guaita, Lucia

    2011-01-01

    We present GalMC (Acquaviva et al 2011), our publicly available Markov Chain Monte Carlo algorithm for SED fitting, show the results obtained for a stacked sample of Lyman Alpha Emitting galaxies at z ~ 3, and discuss the dependence of the inferred SED parameters on the assumptions made in modeling the stellar populations. We also introduce SpeedyMC, a version of GalMC based on interpolation of pre-computed template libraries. While the flexibility and number of SED fitting parameters is redu...

  2. Active versus passive screening for entrance control

    International Nuclear Information System (INIS)

    McCormick, N.J.

    1976-01-01

    The benefits of different entrance control actions are quantitatively assessed by defining a relative improvement index for the screening activity. Three classes of entrance control measures are investigated: the use of a purely active screening measure (such as a portal monitor), the use of a purely passive screening measure (such as personality typing), and the combined use of active and passive measures. Active entrance control measures have been studied previously [McCormick and Erdmann, Nucl. Mat. Manag. 4, (1975)] where it was determined that the relative improvement index is approximately related to the nondetection probability factor r for the protective system by (1-r + r ln r). It is shown here that the relative improvement index for a purely passive screening system also can be approximately expressed in a convenient manner. Because the probability is very small that a sabotage or diversion action would be attempted, the result for passive screening, multiplied by r, may be combined with the factor (1-r + r ln r) to give the relative improvement index for a combined, active-and-passive entrance control system. Results from simple example calculations indicate that passive screening of nuclear plant personnel or applicants for such positions is orders-of-magnitude less effective than portal monitors or reasonable improvements in them. 5 tables

  3. Mathematics for common entrance two answers

    CERN Document Server

    Alexander, Serena

    2015-01-01

    Enables efficient assessment of pupils' performance at Levels 1 and 2 of the ISEB 13+ Common Entrance syllabus. Clear layout saves time marking work and identifies areas requiring further attention. Includes diagrams and working where necessary, to demonstrate how to present high-scoring answers in Level 1 and 2 exams.

  4. Supercalculators and University Entrance Calculus Examinations.

    Science.gov (United States)

    Hong, Ye Yoon; Thomas, Mike; Kiernan, Christine

    2000-01-01

    Investigates whether the use of computer algebra systems could provide a significant advantage to students taking standard university entrance calculus examinations. Indicates that supercalculators would probably provide a significant advantage, particularly for lower-achieving students. Demonstrates that it is possible to write questions in which…

  5. Mathematics for common entrance one answers

    CERN Document Server

    Alexander, Serena

    2015-01-01

    Enables efficient assessment of pupils' performance at Levels 1 and 2 of the ISEB 13+ Common Entrance syllabus. Clear layout saves time marking work and identifies areas requiring further attention. Includes diagrams and working where necessary, to demonstrate how to present high-scoring answers in Level 1 and 2 exams

  6. Krasotshnõje snõ Sed Arte Gallery / Irina Butjajeva

    Index Scriptorium Estoniae

    Butjajeva, Irina

    2007-01-01

    Valgevene kunstnike Jelena Shlegeli, Vladimir Gontsharuki, Dmitri Zenkovitshi ja Dmitri Masli maalinäitus "Valgevene värvilised unenäod" Tallinna galeriis Aatrium. Näitust vahendas Sed Arte Gallery, galerist Olga Ljubaskina

  7. SED fitting with MCMC: methodology and application to large galaxy surveys

    Science.gov (United States)

    Acquaviva, Viviana; Gawiser, Eric; Guaita, Lucia

    2012-08-01

    We present GalMC (Acquaviva et al. 2011), our publicly available Markov Chain Monte Carlo algorithm for SED fitting, show the results obtained for a stacked sample of Lyman Alpha Emitting galaxies at z ~ 3, and discuss the dependence of the inferred SED parameters on the assumptions made in modeling the stellar populations. We also introduce SpeedyMC, a version of GalMC based on interpolation of pre-computed template libraries. While the flexibility and number of SED fitting parameters is reduced with respect to GalMC, the average running time decreases by a factor of 20,000, enabling SED fitting of each galaxy in about one second on a 2.2GHz MacBook Pro laptop, and making SpeedyMC the ideal instrument to analyze data from large photometric galaxy surveys.

  8. SEDS: THE SPITZER EXTENDED DEEP SURVEY. SURVEY DESIGN, PHOTOMETRY, AND DEEP IRAC SOURCE COUNTS

    International Nuclear Information System (INIS)

    Ashby, M. L. N.; Willner, S. P.; Fazio, G. G.; Huang, J.-S.; Hernquist, L.; Hora, J. L.; Arendt, R.; Barmby, P.; Barro, G.; Faber, S.; Guhathakurta, P.; Bell, E. F.; Bouwens, R.; Cattaneo, A.; Croton, D.; Davé, R.; Dunlop, J. S.; Egami, E.; Finlator, K.; Grogin, N. A.

    2013-01-01

    The Spitzer Extended Deep Survey (SEDS) is a very deep infrared survey within five well-known extragalactic science fields: the UKIDSS Ultra-Deep Survey, the Extended Chandra Deep Field South, COSMOS, the Hubble Deep Field North, and the Extended Groth Strip. SEDS covers a total area of 1.46 deg 2 to a depth of 26 AB mag (3σ) in both of the warm Infrared Array Camera (IRAC) bands at 3.6 and 4.5 μm. Because of its uniform depth of coverage in so many widely-separated fields, SEDS is subject to roughly 25% smaller errors due to cosmic variance than a single-field survey of the same size. SEDS was designed to detect and characterize galaxies from intermediate to high redshifts (z = 2-7) with a built-in means of assessing the impact of cosmic variance on the individual fields. Because the full SEDS depth was accumulated in at least three separate visits to each field, typically with six-month intervals between visits, SEDS also furnishes an opportunity to assess the infrared variability of faint objects. This paper describes the SEDS survey design, processing, and publicly-available data products. Deep IRAC counts for the more than 300,000 galaxies detected by SEDS are consistent with models based on known galaxy populations. Discrete IRAC sources contribute 5.6 ± 1.0 and 4.4 ± 0.8 nW m –2 sr –1 at 3.6 and 4.5 μm to the diffuse cosmic infrared background (CIB). IRAC sources cannot contribute more than half of the total CIB flux estimated from DIRBE data. Barring an unexpected error in the DIRBE flux estimates, half the CIB flux must therefore come from a diffuse component.

  9. Reproducible computational biology experiments with SED-ML--the Simulation Experiment Description Markup Language.

    Science.gov (United States)

    Waltemath, Dagmar; Adams, Richard; Bergmann, Frank T; Hucka, Michael; Kolpakov, Fedor; Miller, Andrew K; Moraru, Ion I; Nickerson, David; Sahle, Sven; Snoep, Jacky L; Le Novère, Nicolas

    2011-12-15

    The increasing use of computational simulation experiments to inform modern biological research creates new challenges to annotate, archive, share and reproduce such experiments. The recently published Minimum Information About a Simulation Experiment (MIASE) proposes a minimal set of information that should be provided to allow the reproduction of simulation experiments among users and software tools. In this article, we present the Simulation Experiment Description Markup Language (SED-ML). SED-ML encodes in a computer-readable exchange format the information required by MIASE to enable reproduction of simulation experiments. It has been developed as a community project and it is defined in a detailed technical specification and additionally provides an XML schema. The version of SED-ML described in this publication is Level 1 Version 1. It covers the description of the most frequent type of simulation experiments in the area, namely time course simulations. SED-ML documents specify which models to use in an experiment, modifications to apply on the models before using them, which simulation procedures to run on each model, what analysis results to output, and how the results should be presented. These descriptions are independent of the underlying model implementation. SED-ML is a software-independent format for encoding the description of simulation experiments; it is not specific to particular simulation tools. Here, we demonstrate that with the growing software support for SED-ML we can effectively exchange executable simulation descriptions. With SED-ML, software can exchange simulation experiment descriptions, enabling the validation and reuse of simulation experiments in different tools. Authors of papers reporting simulation experiments can make their simulation protocols available for other scientists to reproduce the results. Because SED-ML is agnostic about exact modeling language(s) used, experiments covering models from different fields of research

  10. Reproducible computational biology experiments with SED-ML - The Simulation Experiment Description Markup Language

    Science.gov (United States)

    2011-01-01

    Background The increasing use of computational simulation experiments to inform modern biological research creates new challenges to annotate, archive, share and reproduce such experiments. The recently published Minimum Information About a Simulation Experiment (MIASE) proposes a minimal set of information that should be provided to allow the reproduction of simulation experiments among users and software tools. Results In this article, we present the Simulation Experiment Description Markup Language (SED-ML). SED-ML encodes in a computer-readable exchange format the information required by MIASE to enable reproduction of simulation experiments. It has been developed as a community project and it is defined in a detailed technical specification and additionally provides an XML schema. The version of SED-ML described in this publication is Level 1 Version 1. It covers the description of the most frequent type of simulation experiments in the area, namely time course simulations. SED-ML documents specify which models to use in an experiment, modifications to apply on the models before using them, which simulation procedures to run on each model, what analysis results to output, and how the results should be presented. These descriptions are independent of the underlying model implementation. SED-ML is a software-independent format for encoding the description of simulation experiments; it is not specific to particular simulation tools. Here, we demonstrate that with the growing software support for SED-ML we can effectively exchange executable simulation descriptions. Conclusions With SED-ML, software can exchange simulation experiment descriptions, enabling the validation and reuse of simulation experiments in different tools. Authors of papers reporting simulation experiments can make their simulation protocols available for other scientists to reproduce the results. Because SED-ML is agnostic about exact modeling language(s) used, experiments covering models from

  11. What can the SEDs of first hydrostatic core candidates reveal about their nature?

    Science.gov (United States)

    Young, Alison K.; Bate, Matthew R.; Mowat, Chris F.; Hatchell, Jennifer; Harries, Tim J.

    2018-02-01

    The first hydrostatic core (FHSC) is the first stable object to form in simulations of star formation. This stage has yet to be observed definitively, although several candidate FHSCs have been reported. We have produced synthetic spectral energy distributions (SEDs) from 3D hydrodynamical simulations of pre-stellar cores undergoing gravitational collapse for a variety of initial conditions. Variations in the initial rotation rate, radius and mass lead to differences in the location of the SED peak and far-infrared flux. Secondly, we attempt to fit the SEDs of five FHSC candidates from the literature and five newly identified FHSC candidates located in the Serpens South molecular cloud with simulated SEDs. The most promising FHSC candidates are fitted by a limited number of model SEDs with consistent properties, which suggests that the SED can be useful for placing constraints on the age and rotation rate of the source. The sources we consider most likely to be in FHSC phase are B1-bN, CB17-MMS, Aqu-MM1 and Serpens South candidate K242. We were unable to fit SerpS-MM22, Per-Bolo 58 and Chamaeleon-MMS1 with reasonable parameters, which indicates that they are likely to be more evolved.

  12. SLAC divertor channel entrance thermal stress analysis

    International Nuclear Information System (INIS)

    Johnson, G.L.; Stein, W.; Lu, S.C.; Riddle, R.A.

    1985-01-01

    X-ray beams emerging from the new SLAC electron-positron storage ring (PEP) impinge on the entrance to tangential divertor channels causing highly localized heating in the channel structure. Analyses were completed to determine the temperatures and thermally-induced stresses due to this heating. These parts are cooled with water flowing axially over them at 30 0 C. The current design and operating conditions should result in the entrance to the new divertor channel operating at a peak temperature of 123 0 C with a peak thermal stress at 91% of yield. Any micro-cracks that form due to thermally-induced stresses should not propagate to the coolant wall nor form a path for the coolant to leak into the storage ring vacuum. 34 figs., 4 tabs

  13. Simulation Experiment Description Markup Language (SED-ML Level 1 Version 3 (L1V3

    Directory of Open Access Journals (Sweden)

    Bergmann Frank T.

    2018-03-01

    Full Text Available The creation of computational simulation experiments to inform modern biological research poses challenges to reproduce, annotate, archive, and share such experiments. Efforts such as SBML or CellML standardize the formal representation of computational models in various areas of biology. The Simulation Experiment Description Markup Language (SED-ML describes what procedures the models are subjected to, and the details of those procedures. These standards, together with further COMBINE standards, describe models sufficiently well for the reproduction of simulation studies among users and software tools. The Simulation Experiment Description Markup Language (SED-ML is an XML-based format that encodes, for a given simulation experiment, (i which models to use; (ii which modifications to apply to models before simulation; (iii which simulation procedures to run on each model; (iv how to post-process the data; and (v how these results should be plotted and reported. SED-ML Level 1 Version 1 (L1V1 implemented support for the encoding of basic time course simulations. SED-ML L1V2 added support for more complex types of simulations, specifically repeated tasks and chained simulation procedures. SED-ML L1V3 extends L1V2 by means to describe which datasets and subsets thereof to use within a simulation experiment.

  14. Simulation Experiment Description Markup Language (SED-ML) Level 1 Version 3 (L1V3).

    Science.gov (United States)

    Bergmann, Frank T; Cooper, Jonathan; König, Matthias; Moraru, Ion; Nickerson, David; Le Novère, Nicolas; Olivier, Brett G; Sahle, Sven; Smith, Lucian; Waltemath, Dagmar

    2018-03-19

    The creation of computational simulation experiments to inform modern biological research poses challenges to reproduce, annotate, archive, and share such experiments. Efforts such as SBML or CellML standardize the formal representation of computational models in various areas of biology. The Simulation Experiment Description Markup Language (SED-ML) describes what procedures the models are subjected to, and the details of those procedures. These standards, together with further COMBINE standards, describe models sufficiently well for the reproduction of simulation studies among users and software tools. The Simulation Experiment Description Markup Language (SED-ML) is an XML-based format that encodes, for a given simulation experiment, (i) which models to use; (ii) which modifications to apply to models before simulation; (iii) which simulation procedures to run on each model; (iv) how to post-process the data; and (v) how these results should be plotted and reported. SED-ML Level 1 Version 1 (L1V1) implemented support for the encoding of basic time course simulations. SED-ML L1V2 added support for more complex types of simulations, specifically repeated tasks and chained simulation procedures. SED-ML L1V3 extends L1V2 by means to describe which datasets and subsets thereof to use within a simulation experiment.

  15. Reduction of low frequency error for SED36 and APS based HYDRA star trackers

    Science.gov (United States)

    Ouaknine, Julien; Blarre, Ludovic; Oddos-Marcel, Lionel; Montel, Johan; Julio, Jean-Marc

    2017-11-01

    In the frame of the CNES Pleiades satellite, a reduction of the star tracker low frequency error, which is the most penalizing error for the satellite attitude control, was performed. For that purpose, the SED36 star tracker was developed, with a design based on the flight qualified SED16/26. In this paper, the SED36 main features will be first presented. Then, the reduction process of the low frequency error will be developed, particularly the optimization of the optical distortion calibration. The result is an attitude low frequency error of 1.1" at 3 sigma along transverse axes. The implementation of these improvements to HYDRA, the new multi-head APS star tracker developed by SODERN, will finally be presented.

  16. EFFECT OF A STELLAR COMPANION ON THE MODELING OF HD 142527 INFRARED SED

    OpenAIRE

    Erick Nagel

    2014-01-01

    The discovery of a companion of the Herbig Ae/Be star HD 142527 motivates the study of the effect that it produces on the SED. The main change on the system configuration is the formation of a gap in the disk. Due to this change, a wall (outer edge of the gap), which is frontally illuminated by stellar radiation is formed. We present a model for the SED, considering all the components: a disk with two gaps (one produced by the stellar companion and the other by potential planets), three walls...

  17. Assessment Practices of School Psychologists When Identifying Children for SED Classes.

    Science.gov (United States)

    Strelnieks, Maija; Wessel, Joan

    This study investigated the procedures used by psychologists in a large midwestern urban area for the initial diagnosis and placement of elementary children with severe emotional disturbance (SED) in educational programs in light of the widespread criticism of the use of projective tests due to the questionable reliability of the tests and…

  18. Observations of subauroral ionospheric dynamics during SED plume passage at Millstone Hill

    Science.gov (United States)

    Zhang, S.; Erickson, P. J.; Coster, A. J.

    2017-12-01

    Storm enhanced density (SED) is a characteristic ionospheric storm time structure, with a significant plasma density enhancement in a narrow zone. SED structures often (but not always) span the continental US with a base in the US northeast at the afternoon and dusk sector, extending westward or northwest into the high latitude dayside cusp region. It is a typical and repeatable space weather phenomenon occurring during the main phase of magnetic storms with intensity ranging from active to disturbed levels. Observations of stormtime ionospheric density enhancement at subauroral latitudes have a long history, and were termed the 'dusk effect' until relatively recently, when dense networks of GNSS receivers have allowed us to view this structure with much finer spatial and temporal resolution. The formation of a SED plume is a topic under intensive community investigation, but in general it is believed that stormtime ionospheric dynamics and processes within the coupling magnetosphere-ionosphere-thermosphere system are responsible. For instance, poleward and sunward plasma drifts at the edge of the expanded dusk sector high-latitude convection can be important. Subauroral polarization stream (SAPS) are often observed at the poleward edge of the SED plume where ionospheric conductivity is low. SAPS is a huge westward ion flow that can convect ionospheric plasma from the afternoon or evening sector where solar photoionization production is waning, creating low density or density troughs. Stormtime penetration electric fields also exist, creating enhanced low and mid latitude upward ion drifts that move ionospheric plasma upward from the low altitude region where they are produced. This provides another important ionization source to contribute to maintaining the SED plume. This paper will provide analysis of the relative strength of these factors by using joint datasets of current geospace storm events obtained with the Millstone Hill incoherent scatter radar, GNSS

  19. Ideological Cooperation versus Cold War Realpolitik - The SED and the Icelandic Socialist Party

    Directory of Open Access Journals (Sweden)

    Valur Ingimundarson

    2007-01-01

    Full Text Available The article deals with the relationship between the East German Socialist Unity Party (SED and the Icelandic Socialist Party (SEI during the Cold War. It details the structural limitations of ideological cooperation between the two parties – Iceland’s NATO membership and the U.S. military presence – as well as its possibilities, especially in the 1950s, through the governmental participation of the SEI. Special attention is devoted to the role played by Einar Olgeirsson, the chairman of the SEI 1939–1968, who was instrumental in forging and developing political, economic, and cultural ties with the SED and the German Democratic Republic. The article argues that this experiment in transnational solidarity between socialist parties from two radically different political systems failed in the end due to several factors, including ideological differences and the political and economic development in Iceland.

  20. Dust Processing in Supernova Remnants: Spitzer MIPS SED and IRS Observations

    Science.gov (United States)

    Hewitt, John W.; Petre, Robert; Katsuda Satoru; Andersen, M.; Rho, J.; Reach, W. T.; Bernard, J. P.

    2011-01-01

    We present Spitzer MIPS SED and IRS observations of 14 Galactic Supernova Remnants previously identified in the GLIMPSE survey. We find evidence for SNR/molecular cloud interaction through detection of [OI] emission, ionic lines, and emission from molecular hydrogen. Through black-body fitting of the MIPS SEDs we find the large grains to be warm, 29-66 K. The dust emission is modeled using the DUSTEM code and a three component dust model composed of populations of big grains, very small grains, and polycyclic aromatic hydrocarbons. We find the dust to be moderately heated, typically by 30-100 times the interstellar radiation field. The source of the radiation is likely hydrogen recombination, where the excitation of hydrogen occurred in the shock front. The ratio of very small grains to big grains is found for most of the molecular interacting SNRs to be higher than that found in the plane of the Milky Way, typically by a factor of 2--3. We suggest that dust shattering is responsible for the relative over-abundance of small grains, in agreement with prediction from dust destruction models. However, two of the SNRs are best fit with a very low abundance of carbon grains to silicate grains and with a very high radiation field. A likely reason for the low abundance of small carbon grains is sputtering. We find evidence for silicate emission at 20 $\\mu$m in their SEDs, indicating that they are young SNRs based on the strong radiation field necessary to reproduce the observed SEDs.

  1. Simulation Experiment Description Markup Language (SED-ML) Level 1 Version 2.

    Science.gov (United States)

    Bergmann, Frank T; Cooper, Jonathan; Le Novère, Nicolas; Nickerson, David; Waltemath, Dagmar

    2015-09-04

    The number, size and complexity of computational models of biological systems are growing at an ever increasing pace. It is imperative to build on existing studies by reusing and adapting existing models and parts thereof. The description of the structure of models is not sufficient to enable the reproduction of simulation results. One also needs to describe the procedures the models are subjected to, as recommended by the Minimum Information About a Simulation Experiment (MIASE) guidelines. This document presents Level 1 Version 2 of the Simulation Experiment Description Markup Language (SED-ML), a computer-readable format for encoding simulation and analysis experiments to apply to computational models. SED-ML files are encoded in the Extensible Markup Language (XML) and can be used in conjunction with any XML-based model encoding format, such as CellML or SBML. A SED-ML file includes details of which models to use, how to modify them prior to executing a simulation, which simulation and analysis procedures to apply, which results to extract and how to present them. Level 1 Version 2 extends the format by allowing the encoding of repeated and chained procedures.

  2. The relativistic titls of Giza pyramids' entrance-passages

    Science.gov (United States)

    Aboulfotouh, H.

    The tilts of Giza pyramids' entrance-passages have never been considered as if they were the result of relativistic mathematical equations, and never been thought to encode the Earth's obliquity parameters. This paper presents an attempt to retrieve the method of establishing the equations that the pyramids' designer used to quantify the entrance-passages' tilts of these architectonic masterpieces. It proves that the pyramids' designer was able to include the geographic, astronomical and time parameters in one relativistic equation, encoding the date of the design of the Giza pyramids in the tilt of the entrance passage of the great pyramid.

  3. Progressive activation of paratrigeminal nucleus during entrance to hibernation

    International Nuclear Information System (INIS)

    Kilduff, T.S.; Sharp, F.R.; Heller, H.C.

    1988-01-01

    The paratrigeminal nucleus (Pa5) undergoes a progressive increase in its uptake of 2-[ 14 C]deoxyglucose (2DG) relative to other brain structures during entrance to hibernation in the ground squirrel. This highly significant increase results in the Pa5 becoming the most highly labeled brain region during hibernation, even though it exhibits one of the lowest levels of 2DG uptake in the brain during the nonhibernating state. The progressive activation of the Pa5 observed during entrance is reversed during arousal from hibernation. These observations and the neuroanatomical projections of the Pa5 implicate this nucleus as playing a role in the entrance and maintenance of the hibernating state

  4. Cuento: Sed

    Directory of Open Access Journals (Sweden)

    Adel López Gómez

    1968-05-01

    Full Text Available Así como el sueño de los hambrientos está poblado de apetitosas viandas, misia Cruzanita Romero vagaba. a lo largo de su intranquilo reposo por un mundo sonoro de fuentes cristalinas e inalcanzables. Y mientras el agua fluía sobre la tierra o se elevaba en ágiles arcos, o reposaba en transparentes vasijas, sus piernas y sus manos permanecían inmóviles. Pero su boca aparecía entreabierta, reseca, sollozante y trémula.

  5. Mr-Moose: An advanced SED-fitting tool for heterogeneous multi-wavelength datasets

    Science.gov (United States)

    Drouart, G.; Falkendal, T.

    2018-04-01

    We present the public release of Mr-Moose, a fitting procedure that is able to perform multi-wavelength and multi-object spectral energy distribution (SED) fitting in a Bayesian framework. This procedure is able to handle a large variety of cases, from an isolated source to blended multi-component sources from an heterogeneous dataset (i.e. a range of observation sensitivities and spectral/spatial resolutions). Furthermore, Mr-Moose handles upper-limits during the fitting process in a continuous way allowing models to be gradually less probable as upper limits are approached. The aim is to propose a simple-to-use, yet highly-versatile fitting tool fro handling increasing source complexity when combining multi-wavelength datasets with fully customisable filter/model databases. The complete control of the user is one advantage, which avoids the traditional problems related to the "black box" effect, where parameter or model tunings are impossible and can lead to overfitting and/or over-interpretation of the results. Also, while a basic knowledge of Python and statistics is required, the code aims to be sufficiently user-friendly for non-experts. We demonstrate the procedure on three cases: two artificially-generated datasets and a previous result from the literature. In particular, the most complex case (inspired by a real source, combining Herschel, ALMA and VLA data) in the context of extragalactic SED fitting, makes Mr-Moose a particularly-attractive SED fitting tool when dealing with partially blended sources, without the need for data deconvolution.

  6. Evaluation of Kerma rate in the skin entrance in interventional procedures guided by fluoroscopy

    International Nuclear Information System (INIS)

    Medeiros, Regina Bitelli; Alves, Fatima Faloppa Rodrigues; Ruberti Filha, Eny M.

    2005-01-01

    Interventional therapeutic procedures guided by fluoroscopy are responsible for delayed exposure to radiation of professionals and patients. The technology employed on generation of the pulsed fluoroscopy can be an important tool of protection used for reducing the exposure time. It generates constant width and varied frequency pulse or width pulse or varied frequency for a constant frequency. The typical doses into the skin and its relationship with the quality of the images in the various technical and operational conditions should be known by the professionals so that they can optimize them. Generated radiation doses were evaluated using the Toshiba Infinitix equipment used in invasive cardiology procedures and electrophysiological studies through the Kerma rate at the entrance of the patient's skin measured throughout the year of 2004. With these information shall be set out the criteria for the decision of the technical-operational conditions that allow minimizing of dose

  7. CellML, SED-ML, and the Physiome Model Repository

    OpenAIRE

    Nickerson, David

    2016-01-01

    Invited presentation delivered at COMBINE 2016.CellML, SED-ML, and the Physiome Model Repository.David Nickerson, Auckland Bioengineering Institute, University of Auckland, New Zealand.CellML is an XML-based protocol for storing and exchanging computer-based mathematical models in an unambiguous, modular, and reusable manner. In addition to introducing CellML, in this presentation I will provide some of physiological examples that have help drive the development and adoption of CellML. I will...

  8. Sensitivity Analysis of ProSEDS (Propulsive Small Expendable Deployer System) Data Communication System

    Science.gov (United States)

    Park, Nohpill; Reagan, Shawn; Franks, Greg; Jones, William G.

    1999-01-01

    This paper discusses analytical approaches to evaluating performance of Spacecraft On-Board Computing systems, thereby ultimately achieving a reliable spacecraft data communications systems. The sensitivity analysis approach of memory system on the ProSEDS (Propulsive Small Expendable Deployer System) as a part of its data communication system will be investigated. Also, general issues and possible approaches to reliable Spacecraft On-Board Interconnection Network and Processor Array will be shown. The performance issues of a spacecraft on-board computing systems such as sensitivity, throughput, delay and reliability will be introduced and discussed.

  9. What the UV SED Tells us About Stellar Populations and Galaxies

    Science.gov (United States)

    Heap, Sara R.

    2011-01-01

    The UV SED parameter b as in f(sub 1) 1(sup b), is commonly used to estimate fundamental properties of high-redshift galaxies including age and metallicity. However, sources and processes other than age and metallicity can influence the value of b. We use the local starforming dwarf galaxy, I Zw 18, in a case study to investigate uncertainties in age and metallicity inferred from b due errors or uncertainties in: mode of star formation (instantaneous starburst vs. continuous SF), dust extinction, nebular continuous emission (2-photon emission, Balmer continuum flux), and presence of older stars.

  10. Self-consistent two-phase AGN torus models⋆. SED library for observers

    Science.gov (United States)

    Siebenmorgen, Ralf; Heymann, Frank; Efstathiou, Andreas

    2015-11-01

    We assume that dust near active galactic nuclei (AGNs) is distributed in a torus-like geometry, which can be described as a clumpy medium or a homogeneous disk, or as a combination of the two (i.e. a two-phase medium). The dust particles considered are fluffy and have higher submillimeter emissivities than grains in the diffuse interstellar medium. The dust-photon interaction is treated in a fully self-consistent three-dimensional radiative transfer code. We provide an AGN library of spectral energy distributions (SEDs). Its purpose is to quickly obtain estimates of the basic parameters of the AGNs, such as the intrinsic luminosity of the central source, the viewing angle, the inner radius, the volume filling factor and optical depth of the clouds, and the optical depth of the disk midplane, and to predict the flux at yet unobserved wavelengths. The procedure is simple and consists of finding an element in the library that matches the observations. We discuss the general properties of the models and in particular the 10 μm silicate band. The AGN library accounts well for the observed scatter of the feature strengths and wavelengths of the peak emission. AGN extinction curves are discussed and we find that there is no direct one-to-one link between the observed extinction and the wavelength dependence of the dust cross sections. We show that objects in the library cover the observed range of mid-infrared colors of known AGNs. The validity of the approach is demonstrated by matching the SEDs of a number of representative objects: Four Seyferts and two quasars for which we present new Herschel photometry, two radio galaxies, and one hyperluminous infrared galaxy. Strikingly, for the five luminous objects we find that pure AGN models fit the SED without needing to postulate starburst activity. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.The SED

  11. Constraining the Stellar Populations and Star Formation Histories of Blue Compact Dwarf Galaxies with SED Fits

    Energy Technology Data Exchange (ETDEWEB)

    Janowiecki, Steven [International Center for Radio Astronomy Research, M468, The University of Western Australia, 35 Stirling Highway, Crawley, Western Australia, 6009 (Australia); Salzer, John J.; Zee, Liese van [Department of Astronomy, Indiana University, 727 East Third Street, Bloomington, IN 47405 (United States); Rosenberg, Jessica L. [Department of Physics and Astronomy, George Mason University, Fairfax, VA 22030 (United States); Skillman, Evan, E-mail: steven.janowiecki@uwa.edu.au [Minnesota Institute for Astrophysics, University of Minnesota, 116 Church Street, SE Minneapolis, MN, 55455 (United States)

    2017-02-10

    We discuss and test possible evolutionary connections between blue compact dwarf galaxies (BCDs) and other types of dwarf galaxies. BCDs provide ideal laboratories to study intense star formation episodes in low-mass dwarf galaxies, and have sometimes been considered a short-lived evolutionary stage between types of dwarf galaxies. To test these connections, we consider a sample of BCDs as well as a comparison sample of nearby galaxies from the Local Volume Legacy (LVL) survey for context. We fit the multi-wavelength spectral energy distributions (SED, far-ultra-violet to far-infrared) of each galaxy with a grid of theoretical models to determine their stellar masses and star formation properties. We compare our results for BCDs with the LVL galaxies to put BCDs in the context of normal galaxy evolution. The SED fits demonstrate that the star formation events currently underway in BCDs are at the extreme of the continuum of normal dwarf galaxies, both in terms of the relative mass involved and in the relative increase over previous star formation rates. Today’s BCDs are distinctive objects in a state of extreme star formation that is rapidly transforming them. This study also suggests ways to identify former BCDs whose star formation episodes have since faded.

  12. MarsSedEx III: linking Computational Fluid Dynamics (CFD) and reduced gravity experiments

    Science.gov (United States)

    Kuhn, N. J.; Kuhn, B.; Gartmann, A.

    2015-12-01

    Nikolaus J. Kuhn (1), Brigitte Kuhn (1), and Andres Gartmann (2) (1) University of Basel, Physical Geography, Environmental Sciences, Basel, Switzerland (nikolaus.kuhn@unibas.ch), (2) Meteorology, Climatology, Remote Sensing, Environmental Sciences, University of Basel, Switzerland Experiments conducted during the MarsSedEx I and II reduced gravity experiments showed that using empirical models for sediment transport on Mars developed for Earth violates fluid dynamics. The error is caused by the interaction between runing water and sediment particles, which affect each other in a positive feedback loop. As a consequence, the actual flow conditions around a particle cannot be represented by drag coefficients derived on Earth. This study exmines the implications of such gravity effects on sediment movement on Mars, with special emphasis on the limits of sandstones and conglomerates formed on Earth as analogues for sedimentation on Mars. Furthermore, options for correctiong the errors using a combination of CFD and recent experiments conducted during the MarsSedEx III campaign are presented.

  13. Traffic disruption at Entrance B -TRAM- related work

    CERN Multimedia

    Infrastructure and General Services Department

    2010-01-01

    Due to work being carried out for the TRAM we inform you that vehicles coming from Geneva will be prohibited from turning left into Entrance B. This restriction will be in place for approx. 10 weeks*) starting from Monday 30 August 2010. You are highly recommended to enter CERN through Entrance A during this period even though a diversion will be put in place to allow access to CERN from Entrance B (as shown in the attached sketch). In addition, approx. 20 car parking spaces will be temporarily unavailable at the western end of the flags car park. We thank you in advance for your kind understanding. ______________ *) The exact end date of the work will be communicated in due course. GS-SEM Group

  14. The University Entrance Exam that Diversified and the Problem

    Science.gov (United States)

    Kondo, Osamu

    The percentage of students who go on to universities or junior colleges is over fifty percent which is more than half of high school students. However the nation's birthrate is in decline and the total number of university-age children shows a declining tendency. Hence we cannot expect an increase in the number of applicants in the future. On the other hand, the number of universities has been increasing year by year. The competition among universities to survive is very fierce. The diversification of entrance examination is a symbol of this competition. By diversifying entrance exams, universities aimed at the quality of excellent students in the beginning. However, they have changed their direction to pursue the quantity of students. As of Today the entrance examination is losing its original starting function which means most or all applicants can enter universities. It is time all of the universities return to its starting line.

  15. Prévessin site – Pedestrian and cycle entrances

    CERN Multimedia

    GS-IS

    2013-01-01

      A second entrance for pedestrians and cyclists on Route du Maroc will be opened and the existing entrance on Chemin du Moulin des Ponts will be re-opened: - for the period 2 April to 31 October 2013, - from 7.00 a.m. to 9.00 a.m. and from 5.00 p.m. to 7.00 p.m. on working days (Monday to Friday). IMPORTANT: all users must show their access cards to the security guard as a matter of course when passing through the gates, both on entering and leaving the site.

  16. A cross-section sensitivity and uncertainty analysis on fusion reactor blankets with SAD/SED effect

    International Nuclear Information System (INIS)

    Furuta, Kazuo; Oka, Yoshiaki; Kondo, Shunsuke

    1986-01-01

    A cross-section sensitivity and uncertainty analysis on four types of fusion reactor blankets has been performed, based on cross-section covariance matrices. The design parameters investigated in the analysis include the tritium breeding ratio, the neutron heating and the fast neutron leakage flux from the inboard shield. Uncertainities in Secondary Angular Distribution (SAD) and Secondary Energy Distribution (SED) of scattered neutrons have been considered for lithium. The collective standard deviation, due to uncertainties in the evaluated cross-section data presently available, is 2-4% in the tritium breeding ratio, 2-3% in the neutron heating, and 10-20% in the fast neutron leakage flux. Contributions from SAD/SED uncertainties are significant for some parameters, such as those investigated in the present study. SAD/SED uncertainties should be considered in the sensitivity and uncertainty analysis on nuclear design of fusion reactors. (orig.)

  17. Practical experience of monitoring patient dose

    Energy Technology Data Exchange (ETDEWEB)

    McDonnell, C.; Shrimpton, P. (National Radiological Protection Board, Chilton (United Kingdom)); O' Mahoney, M. (National Radiological Protection Board, Leeds (United Kingdom)); Foster, J. (Nuffield Hospitals, Surbiton (United Kingdom))

    1994-05-01

    NRPB recommends the use of reference dose levels for diagnostic medical exposures as an aid to patient dose reduction, but is this approach effective This article describes the broadly encouraging experiences of one large group of hospitals in carrying out measurements of entrance surface dose on patients undergoing some common types of x-ray examination. (author).

  18. 1979 National Unified Entrance Examination for Institutions of Higher Education.

    Science.gov (United States)

    Chinese Education, 1979

    1979-01-01

    The article presents translations of Chinese college entrance examinations in the fields of politics, Chinese language and literature, mathematics, humanities, physics, chemistry, history, geography, and English. Translations are also presented of the 1979 review syllabus for 1979 for the same subject areas. (DB)

  19. The English in Japanese University Entrance Examinations: A Sociocultural Analysis.

    Science.gov (United States)

    Locastro, Virginia

    1990-01-01

    Sociocultural and historical examination of the kind of English used in Japanese university entrance examinations suggests that such usage mirrors and reinforces general Japanese attitudes about language, language learning, and national interests, resulting in a closed system highly resistant to change. (28 references) (Author/CB)

  20. Early College Entrance: How Will My Child Do?

    Science.gov (United States)

    Chung, Rachel U.; Hertzog, Nancy B.

    2014-01-01

    Early college entrance is a form of acceleration, or the process of advancing students in academic programs faster than their same-aged peers. Many early entrants have demonstrated academic ability to achieve at high levels but they exhibit tremendous variety in their age, specific abilities, social and emotional maturity, family support, and…

  1. China’s Entrance to the WTO and Financial Reform

    Directory of Open Access Journals (Sweden)

    Ki-Soon Park

    2000-09-01

    Full Text Available The openness and liberalization of China’s financial market is expected to accelerate with her entrance to the WTO. China plans to carry out liberalization measures, including the expansion of the Renminbi business scope. Openness and liberalization will expedite the integration of internal and external sectors, thereby making the domestic financial market more vulnerable to environmental changes. Consequently, China should establish a strong financial system to efficiently cope with the contagion effects of an external financial crisis. However, China’s financial system is still very weak, mainly due to the enormous bad loans to SOEs (state-owned enterprises. Accordingly, the Chinese government should carry out financial reform measures such as strengthening the financial supervision system, dealing with bad bank loans and restructuring the financial institutions. On the whole, China’s entrance to the WTO is expected to have a positive influence on her financial sector by accelerating such reform policies as financial reform and SOE reform. Entrance to the WTO will make society recognize the necessity of reform and openness. The Chinese government can decide to push some difficult reform policies which would not have been considered without WTO entrance.

  2. Modifications to improve entrance slit thermal stability for grasshopper monochromators

    Science.gov (United States)

    Wallace, Daniel J.; Rogers, Gregory C.; Crossley, Sherry L.

    1994-08-01

    As new monochromators are designed for high-flux storage rings, computer modeling and thermal engineering can be done to process increased heat loads and achieve mechanical stability. Several older monochromators, such as the Mark 2 and Mark 5 Grasshopper monochromators, which were designed in 1974, have thermal instabilities in their entrance slit mechanisms. The Grasshoppers operating with narrow slits experience closure of the entrance slit from thermal expansion. In extreme cases, the thermal expansion of the precision components has caused permanent mechanical damage, leaving the slit uncalibrated and/or inoperable. For the Mark 2 and Mark 5 Grasshopper monochromators at the Synchrotron Radiation Center, the original 440 stainless steel entrance slit jaws were retrofitted with an Invar (low expansion Fe, Ni alloy) slit jaw. To transfer the heat from the critical components, two flexible heat straps of Cu were attached. These changes allow safe operation with a 10 μm entrance slit width where the previous limit was 30 μm. After an initial 2 min equilibration, the slit remains stable to 10%, with 100 mA of beam current. Additional improvements in slit thermal stability are planned for a third Grasshopper.

  3. Loads on Entrance Platforms for Offshore Wind Turbines

    DEFF Research Database (Denmark)

    Frigaard, Peter; Andersen, Thomas Lykke; Ramirez, Jorge Robert Rodriguez

    2010-01-01

    The present paper gives an overview of the performed large scale tests in GWK, Hannover for studying wave run-up generated forces on wind turbine entrance platforms. The run-up height and velocity was measured by use of high speed video recordings supplemented by some wave gauges mounted at the p...

  4. Constructing and Monitoring the Infrared SED of the First Known Recent Stellar Merger

    Science.gov (United States)

    McCollum, Bruce; Laine, Seppo; Bruhweiler, Frederick; Rottler, Lee

    2012-12-01

    Stellar mergers have long been thought to be astrophysically important to the evolution and global properties of dense stellar aggregates and even open clusters. However, the study of this phenomenon has until now been severely impeded by the lack of any definite, recent merger with which to compare models. It was recently realized that a 2008 nova was in fact a contact binary which erupted when the two stars finally merged. We have obtained post-merger infrared observations which show a large IR excess and a nonstellar SED which have changed subsantially over time, and near-IR emission lines from shocked material. This object is an important opportunity to learn about the nature and time evolution of recent merger products, and to assemble a unique data set which will be used for many years as a basis for modeling stellar mergers.

  5. The grid-scan. A novel method for a less biased broadband SED modeling

    Energy Technology Data Exchange (ETDEWEB)

    Doert, Marlene [Ruhr-Universitaet Bochum (Germany); Paneque, David [Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2016-07-01

    We present a novel strategy for the modeling of blazar SEDs in the scope of current emission models: the grid-scan modeling. With an unbiased and uniform scan of the multi-dimensional parameter space of current emission models, e.g. the SSC model, and an a posteriori evaluation of the model-to-data agreement, independent sets of equally good model representations can be found. This variety of models generally includes different valid physical scenarios, which offer a more complete picture than single ''best'' solutions found by minimizers or the often-practised ''eyeball-fit''. Additionally, the grid-scan also allows to quantify how well the individual model parameters get constrained by any given experimental data set. The method will be introduced using the example of multi-wavelength spectral measurements of the blazar Markarian 501.

  6. Establishing a Network of Next Generation SED standards with DA White Dwarfs

    Science.gov (United States)

    Saha, Abhijit

    2014-10-01

    Photometric calibration uncertainties are the dominant source of error in current type Ia supernova dark energy studies, and other forefront cosmology efforts, e.g., photo-redshifts for weak lensing mass tomography. Modern 'all-sky' surveys require a network of calibration stars with 1) known SEDs (to properly and unambiguously account for filter differences), and 2) that are on a common photometric zero-point scale. HST enables us to establish this essential network of faint spectrophotometric standards, by eliminating the time-variable Earth's atmosphere, and by exploiting the well-understood energy distributions of DA white dwarfs. We have selected a set of DA WD targets that will have SNR ~200 in the LSST (and PanSTARRS and Dark Energy Survey) survey images, while avoiding saturation. This means they will be included in the surveys, and will directly calibrate the data products. By using ground-based spectra of Balmer lines to obtain the two parameters (temperature and log(g)) that determine the SED, we can use broadband HST photometry to set the overall flux scale for each source, and determine any applicable reddening. Thus calibrated, these standards can then be used as flux standards at wavelengths well beyond the range of HST, and in any arbitrary, but defined passband. This precision photometric heritage from HST benefits essentially all existing and upcoming surveys, standardizes (spectro)photometry across observatories and facilities, and directly addresses one of the current barriers to understanding the nature of dark energy. In our Cycle 20 program we achieve sub-percent accuracy. Here we propose improvements in experimental design from lessons learned.

  7. Video dosimetry: evaluation of X-radiation dose by video fluoroscopic image

    International Nuclear Information System (INIS)

    Nova, Joao Luiz Leocadio da; Lopes, Ricardo Tadeu

    1996-01-01

    A new methodology to evaluate the entrance surface dose on patients under radiodiagnosis is presented. A phantom is used in video fluoroscopic procedures in on line video signal system. The images are obtained from a Siemens Polymat 50 and are digitalized. The results show that the entrance surface dose can be obtained in real time from video imaging

  8. Staphylococcus aureus entrance into the dairy chain: Tracking S. aureus from dairy cow to cheese

    Directory of Open Access Journals (Sweden)

    Judith Kümmel

    2016-10-01

    Full Text Available Staphylococcus aureus is one of the most important contagious mastitis pathogens in dairy cattle. Due to its zoonotic potential, control of S. aureus is not only of great economic importance in the dairy industry but also a significant public health concern. The aim of this study was to decipher the potential of bovine udder associated S. aureus as reservoir for S. aureus contamination in dairy production and processing. From 18 farms, delivering their milk to an alpine dairy plant for the production of smeared semi-hard and hard cheese. 1176 quarter milk (QM samples of all cows in lactation (n = 294 and representative samples form bulk tank milk (BTM of all farms were surveyed for coagulase positive (CPS and coagulase negative Staphylococci (CNS. Furthermore, samples from different steps of the cheese manufacturing process were tested for CPS and CNS. As revealed by chemometric-assisted FTIR spectroscopy and molecular subtyping (spa typing and multi locus sequence typing, dairy cattle represent indeed an important, yet underreported, entrance point of S. aureus into the dairy chain. Our data clearly show that certain S. aureus subtypes are present in primary production as well as in the cheese processing at the dairy plant. However, although a considerable diversity of S. aureus subtypes was observed in QM and BTM at the farms, only certain S. aureus subtypes were able to enter and persist in the cheese manufacturing at the dairy plant and could be isolated from cheese until day fourteen of ripening. Farm strains belonging to the FTIR cluster B1 and B3, which show genetic characteristics (t2953, ST8, enterotoxin profile: sea/sed/sej of the recently described S. aureus genotype B, most successfully contaminated the cheese production at the dairy plant. Thus our study fosters the hypothesis that genotype B S. aureus represent a specific challenge in control of S. aureus in the dairy chain that requires effective clearance strategies and hygienic

  9. An assessment of the fine sediment dynamics in an upland river system: INCA-Sed modifications and implications for fisheries.

    Science.gov (United States)

    Lazar, Attila N; Butterfield, Dan; Futter, Martyn N; Rankinen, Katri; Thouvenot-Korppoo, Marie; Jarritt, Nick; Lawrence, Deborah S L; Wade, Andrew J; Whitehead, Paul G

    2010-05-15

    There is a need for better links between hydrology and ecology, specifically between landscapes and riverscapes to understand how processes and factors controlling the transport and storage of environmental pollution have affected or will affect the freshwater biota. Here we show how the INCA modelling framework, specifically INCA-Sed (the Integrated Catchments model for Sediments) can be used to link sediment delivery from the landscape to sediment changes in-stream. INCA-Sed is a dynamic, process-based, daily time step model. The first complete description of the equations used in the INCA-Sed software (version 1.9.11) is presented. This is followed by an application of INCA-Sed made to the River Lugg (1077 km(2)) in Wales. Excess suspended sediment can negatively affect salmonid health. The Lugg has a large and potentially threatened population of both Atlantic salmon (Salmo salar) and Brown Trout (Salmo trutta). With the exception of the extreme sediment transport processes, the model satisfactorily simulated both the hydrology and the sediment dynamics in the catchment. Model results indicate that diffuse soil loss is the most important sediment generation process in the catchment. In the River Lugg, the mean annual Guideline Standard for suspended sediment concentration, proposed by UKTAG, of 25 mg l(-1) is only slightly exceeded during the simulation period (1995-2000), indicating only minimal effect on the Atlantic salmon population. However, the daily time step simulation of INCA-Sed also allows the investigation of the critical spawning period. It shows that the sediment may have a significant negative effect on the fish population in years with high sediment runoff. It is proposed that the fine settled particles probably do not affect the salmonid egg incubation process, though suspended particles may damage the gills of fish and make the area unfavourable for spawning if the conditions do not improve. Copyright 2010 Elsevier B.V. All rights reserved.

  10. sedFlow – a tool for simulating fractional bedload transport and longitudinal profile evolution in mountain streams

    Directory of Open Access Journals (Sweden)

    F. U. M. Heimann

    2015-01-01

    floods. The model is intended for temporal scales from the individual event (several hours to few days up to longer-term evolution of stream channels (several years. The envisaged spatial scale covers complete catchments at a spatial discretisation of several tens of metres to a few hundreds of metres. sedFlow can deal with the effects of streambeds that slope uphill in a downstream direction and uses recently proposed and tested approaches for quantifying macro-roughness effects in steep channels. sedFlow offers different options for bedload transport equations, flow-resistance relationships and other elements which can be selected to fit the current application in a particular catchment. Local grain-size distributions are dynamically adjusted according to the transport dynamics of each grain-size fraction. sedFlow features fast calculations and straightforward pre- and postprocessing of simulation data. The high simulation speed allows for simulations of several years, which can be used, e.g., to assess the long-term impact of river engineering works or climate change effects. In combination with the straightforward pre- and postprocessing, the fast calculations facilitate efficient workflows for the simulation of individual flood events, because the modeller gets the immediate results as direct feedback to the selected parameter inputs. The model is provided together with its complete source code free of charge under the terms of the GNU General Public License (GPL (www.wsl.ch/sedFlow. Examples of the application of sedFlow are given in a companion article by Heimann et al. (2015.

  11. COMPARISON OF THE TEST VARIANTS IN ENTRANCE EXAMINATIONS

    Directory of Open Access Journals (Sweden)

    KLŮFA, Jindřich

    2016-12-01

    Full Text Available The paper contains an analysis of the differences of number of points in the test in mathematics between test variants, which were used in the entrance examinations at the Faculty of Business Administration at University of Economics in Prague in 2015. The differences may arise due to the varying difficulty of variants for students, but also because of the different level of knowledge of students who write these variants. This problem we shall study in present paper. The aim of this paper is to study dependence of the results of entrance examinations in mathematics on test variants. The results obtained will be used for further improvement of the admission process at University of Economics.

  12. Entrance channel systematics of pre-scission neutron multiplicities

    International Nuclear Information System (INIS)

    Shareef, M.; Prasad, E.; Chatterjee, A.

    2016-01-01

    Statistical model analysis has been performed for the available neutron multiplicity (ν_p_r_e) data in the literature. Larger ν_p_r_e values for more symmetric reactions have been observed in comparison with asymmetric reactions forming the same compound nucleus, in most cases. A reverse trend has also been noticed in a few cases. A systematic entrance channel dependence of fission timescale is brought out in this work. Fission timescales calculated using the experimental ν_p_r_e values fall into two distinct groups according to the entrance channel mass asymmetry of the reaction with respect to the Businaro-Gallone critical mass asymmetry. The difference in the delay between these two groups ranges between 20 and 100 zs, which is larger than that reported in some cases. (orig.)

  13. Magnetic re-entrance in intermediate valence compounds

    International Nuclear Information System (INIS)

    Allub, R.; Machiavelli, O.; Balseiro, C.; Alascio, B.

    1980-01-01

    The possibility is explored of magnetic re-entrance in intermediate valence compounds. Using a simplified Anderson-Lattice model the pressure-temperature magnetic phase diagram is obtained. This diagram shows that for some value of the microscopic parameters the temperature induced two transitions (non-magnetic to magnetically ordered to paramagnetic). The magnetization and the average occupation number of the localized state are calculated. Estimations of the observability of the effect in systems like CeAl 2 are made. (author)

  14. The methodology proposed to estimate the absorbed dose at the entrance of the labyrinth in HDR brachytherapy facilities with IR-192; Propuesta de metodologia para estimar la dosis absorbida en la entrada del laberinto en instalaciones de braquiterapia HDR con Ir-192

    Energy Technology Data Exchange (ETDEWEB)

    Pujades, M. C.; Perez-Calatayud, J.; Ballester, F.

    2012-07-01

    In the absence of procedure for evaluating the design of a brachytherapy (BT) vault with maze from the point of view of radiation protection, usually formalism of external radiation is adapted. The purpose of this study is to adapt the methodology described by the National council on Radiological Protection and Measurements Report 151 (NCRP 151). Structural Shielding Design for megavoltage X-and Gamma-Ray Radiotherapy facilities, for estimating dose at the door in BT and its comparison with the results megavoltage X-and Gamma-Ray Radiotherapy Facilities, for estimating dose at the door in BT and its comparison with the results obtained by the method of Monte Carlo (MC) for a special case of bunker. (Author) 17 refs.

  15. The creation of economic policy after the entrance to EU

    Directory of Open Access Journals (Sweden)

    Vodzinská Vladimíra

    2004-06-01

    Full Text Available The Slovac republic, analogous to other countries which came in the Europe Union this year, is standing before solving the problem of real integration to the economic and monetary system.Submitted article shows, that preliminary transformation process of national economy, specially the privatization process of national property was remarked by influencies, which has led to the creation of social excessively high losts and very negative affected also for the creation and realization the economis policy of the state.In this signification remarked also bargaining position of Slovac republic in so called before entrance negotiations with the representants from Europe union as well the character of risks related to urgency subserve the main liability in conection with the entrance to the EU, i.e. the convergency criterias specified by maastrichts agreement.In this continuity becomes the cardinal problem of the economic policy of the state alternative modeling of exercitation its fiscal and monetary tools, which permits of such time and general harmonising of real and nominal processes convergency, which will have tenable social character.Videlicet, the entrance fixation of the Slovac republic to the ERM2 for the year 2006 and to the eurozone for the year 2008, or 2009 involves to assert the tools of economic policy as, that the economic increase couched in expected long tenable development of GDP, balance of payments, inflation and unemployment was social effective.In this signification are intraducing some risks and factors, which can work against these development.

  16. 30 CFR 18.29 - Access openings and covers, including unused lead-entrance holes.

    Science.gov (United States)

    2010-07-01

    ... lead-entrance holes. 18.29 Section 18.29 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... unused lead-entrance holes. (a) Access openings in explosion-proof enclosures will be permitted only... Figure 1 in Appendix II.) (c) Holes in enclosures that are provided for lead entrances but which are not...

  17. Substation interference on gas entrance of industrial plants

    Energy Technology Data Exchange (ETDEWEB)

    Freire, Paulo Edmundo; Giacommelo, Claudinei [PAIOL Engenharia, Paulinia, SP (Brazil)

    2009-12-19

    Industrial plants often have medium or high voltage electrical power entrance and also gas feeders. Often the main substation is located near the gas entrance, in the utilities area. When the occurrence of a phase to ground short-circuit in the substation, the pipeline and gas entrance that serves the plant may be exposed to high voltage soil potential, of the order of a few kilovolts, due to resistive coupling with the substation ground mesh. The consequences of this situation are reflected in various risks, with emphasis on: damage to the protective coating of the duct, due to the increased soil potential, in excess of its dielectric supportability (typically on the order of 5 kV); spread of potentially hazardous to duct exposed parts (valves, measuring place etc.); and damage to cathodic protection system components, as rectifier and insulating joins at gas entrance. This paper presents the investigations conducted in a factory that has a 69 kV main substation very close to the gas entrance, the order of a few meters away. The substation phase to ground short-circuit current is 7 kA, what causes a 9 kV soil potential near the gas pipe. It is presented the methodology for modeling the various elements involved in this process, the results of simulations made, arrangements been taken to reduce soil potential next to the duct to levels below 5 kV, and the measures for people and insulating joins protection. It is important to note that such problems usually will be solved with measures involving the entire grounding system of the industrial complex and also close to the duct (outside the industrial plant). The gas distribution companies should require from customers where this situation occurs, to ensure safety for people who have access to elements of its network, and for the integrity of their own ducts and cathodic protection components. The computer simulations developed for this work were made with the software Auto Grid, developed by the Canadian company Safe

  18. Spatially unresolved SED fitting can underestimate galaxy masses: a solution to the missing mass problem

    Science.gov (United States)

    Sorba, Robert; Sawicki, Marcin

    2018-05-01

    We perform spatially resolved, pixel-by-pixel Spectral Energy Distribution (SED) fitting on galaxies up to z ˜ 2.5 in the Hubble eXtreme Deep Field (XDF). Comparing stellar mass estimates from spatially resolved and spatially unresolved photometry we find that unresolved masses can be systematically underestimated by factors of up to 5. The ratio of the unresolved to resolved mass measurement depends on the galaxy's specific star formation rate (sSFR): at low sSFRs the bias is small, but above sSFR ˜ 10-9.5 yr-1 the discrepancy increases rapidly such that galaxies with sSFRs ˜ 10-8 yr-1 have unresolved mass estimates of only one-half to one-fifth of the resolved value. This result indicates that stellar masses estimated from spatially unresolved data sets need to be systematically corrected, in some cases by large amounts, and we provide an analytic prescription for applying this correction. We show that correcting stellar mass measurements for this bias changes the normalization and slope of the star-forming main sequence and reduces its intrinsic width; most dramatically, correcting for the mass bias increases the stellar mass density of the Universe at high redshift and can resolve the long-standing discrepancy between the directly measured cosmic SFR density at z ≳ 1 and that inferred from stellar mass densities (`the missing mass problem').

  19. Two-dimensional cross-section and SED uncertainty analysis for the Fusion Engineering Device (FED)

    International Nuclear Information System (INIS)

    Embrechts, M.J.; Urban, W.T.; Dudziak, D.J.

    1982-01-01

    The theory of two-dimensional cross-section and secondary-energy-distribution (SED) sensitivity was implemented by developing a two-dimensional sensitivity and uncertainty analysis code, SENSIT-2D. Analyses of the Fusion Engineering Design (FED) conceptual inboard shield indicate that, although the calculated uncertainties in the 2-D model are of the same order of magnitude as those resulting from the 1-D model, there might be severe differences. The more complex the geometry, the more compulsory a 2-D analysis becomes. Specific results show that the uncertainty for the integral heating of the toroidal field (TF) coil for the FED is 114.6%. The main contributors to the cross-section uncertainty are chromium and iron. Contributions to the total uncertainty were smaller for nickel, copper, hydrogen and carbon. All analyses were performed with the Los Alamos 42-group cross-section library generated from ENDF/B-V data, and the COVFILS covariance matrix library. The large uncertainties due to chromium result mainly from large convariances for the chromium total and elastic scattering cross sections

  20. Energy policy of the 10. SED congress and peaceful use of nuclear power in the GDR

    International Nuclear Information System (INIS)

    Mittsinger, V.; Krauze, Kh.; Kremer, Yu.

    1984-01-01

    The state-of-the-art and perspectives on the development of the GDR energy and raw material basis are considered. The main directions in the GDR energy strategy for the 80-ies adopted by the 10-th SED Congress are discussed. It is noted that the NPP share in the total power generation which in 1970 had been below 1% increased up to 12% by 1981. In 1983 commercial heat consumption was employed for the first time from NPP units with the capacity of 440 MW for the heat supply of a town of Greifswald. The nuclear power development program udtil the year of 2000 envisages to complete the construction of the Bruno Lensehner NPP and to put four units with WWER-440 intoR operation before 1990. This NPP with the total capacity of 3520 MW must become a great contribution to a regular power supply of the country. It is planned to put into operation the first power unit with the capacity of 10U0 MW to be built according to the Soviet standard project. In future this type of reactors will be used as serial to expand the GDR nuclear engineering basis

  1. SEDS MIL-STD-1773 fiber optic data bus: Proton irradiation test results and spaceflight SEU data

    Energy Technology Data Exchange (ETDEWEB)

    LaBel, K.A.; Stassinopoulos, E.G.; Miller, J.T. (NASA/GSFC, Greenbelt, MD (United States)); Marshall, P. (NRL/SFA, Washington, DC (United States)); Dale, C. (NRL, Washington, DC (United States)); Crabtree, C.M. (Hughes/ST Systems Corp., Seabrook, MD (United States)); Gates, M.M. (Jackson and Tull, Seabrook, MD (United States))

    1993-12-01

    The Small Explorer Data System (SEDS) was launched in July of 1992 as part of the Solar Anomalous Magnetospheric Particle Explorer (SAMPEX) mission. The SEDS utilizes NASA's first MIL-STD-1773 Fiber Optic Multiplexed Data Bus (or 1773 bus) to communicate with other spacecraft subsystems in the space environment. The 1773 bus is the fiber optic version of the MIL-STD-1553 Data Bus, a electronic wire bus used in many avionics applications. The authors present proton test and space flight single event effect data for NASA's first fiber optic data bus. Bit error rate predictions based on a new proton direct ionization model agree well with flight data for proton belt and solar flare effects.

  2. Determining the sources of fine-grained sediment using the Sediment Source Assessment Tool (Sed_SAT)

    Science.gov (United States)

    Gorman Sanisaca, Lillian E.; Gellis, Allen C.; Lorenz, David L.

    2017-07-27

    A sound understanding of sources contributing to instream sediment flux in a watershed is important when developing total maximum daily load (TMDL) management strategies designed to reduce suspended sediment in streams. Sediment fingerprinting and sediment budget approaches are two techniques that, when used jointly, can qualify and quantify the major sources of sediment in a given watershed. The sediment fingerprinting approach uses trace element concentrations from samples in known potential source areas to determine a clear signature of each potential source. A mixing model is then used to determine the relative source contribution to the target suspended sediment samples.The computational steps required to apportion sediment for each target sample are quite involved and time intensive, a problem the Sediment Source Assessment Tool (Sed_SAT) addresses. Sed_SAT is a user-friendly statistical model that guides the user through the necessary steps in order to quantify the relative contributions of sediment sources in a given watershed. The model is written using the statistical software R (R Core Team, 2016b) and utilizes Microsoft Access® as a user interface but requires no prior knowledge of R or Microsoft Access® to successfully run the model successfully. Sed_SAT identifies outliers, corrects for differences in size and organic content in the source samples relative to the target samples, evaluates the conservative behavior of tracers used in fingerprinting by applying a “Bracket Test,” identifies tracers with the highest discriminatory power, and provides robust error analysis through a Monte Carlo simulation following the mixing model. Quantifying sediment source contributions using the sediment fingerprinting approach provides local, State, and Federal land management agencies with important information needed to implement effective strategies to reduce sediment. Sed_SAT is designed to assist these agencies in applying the sediment fingerprinting

  3. Prévessin site – Pedestrian and cycle entrances

    CERN Multimedia

    GS-DI

    2014-01-01

    Entrances for pedestrians and cyclists on Route du Maroc and on Chemin du Moulin des Ponts, in Prévessin, will be re-opened:   from 7 April to 31 October 2014, from 7.00 a.m. to 9.00 a.m. and from 5.00 p.m. to 7.00 p.m. on working days (Monday to Friday).   IMPORTANT: all users must show their access cards to the security guard as a matter of course when passing through the gates, both on entering and leaving the site.

  4. Prévessin site: Pedestrian and cycle entrance

    CERN Multimedia

    2015-01-01

    The entrance to the Prévessin site for pedestrians and cyclists on Chemin du Moulin des Ponts will be re-opened: from 7 April to 30 October 2015, from 7.00 a.m. to 9.00 a.m. and from 5.00 p.m. to 7.00 p.m. on working days (Monday to Friday).   IMPORTANT: all users must show their access cards to the security guard as a matter of course when passing through the gates, both on entering and leaving the site.

  5. Development of a New Zealand SedNet model for assessment of catchment-wide soil-conservation works

    Science.gov (United States)

    Dymond, John R.; Herzig, Alexander; Basher, Les; Betts, Harley D.; Marden, Mike; Phillips, Chris J.; Ausseil, Anne-Gaelle E.; Palmer, David J.; Clark, Maree; Roygard, Jon

    2016-03-01

    Much hill country in New Zealand has been converted from indigenous forest to pastoral agriculture, resulting in increased soil erosion. Following a severe storm that hit the Manawatu-Wanaganui region in 2004 and caused 62,000 landslides, the Horizons Regional Council have implemented the Sustainable Land Use Initiative (SLUI), a programme of widespread soil conservation. We have developed a New Zealand version (SedNetNZ) of the Australian SedNet model to evaluate the impact of the SLUI programme in the 5850 km2 Manawatu catchment. SedNetNZ spatially distributes budgets of fine sediment in the landscape. It incorporates landslide, gully, earthflow erosion, surficial erosion, bank erosion, and flood-plain deposition, the important forms of soil erosion in New Zealand. Modelled suspended sediment loads compared well with measured suspended sediment loads with an R2 value of 0.85 after log transformation. A sensitivity analysis gave the uncertainty of estimated suspended sediment loads to be approximately plus or minus 50% (at the 95% confidence level). It is expected that by 2040, suspended sediment loads in targeted water management zones will decrease by about 40%. The expected decrease for the whole catchment is 34%. The expected reduction is due to maturity of tree planting on land at risk to soil erosion. The 34% reduction represents an annual rate of return of 20% on 20 million NZ of investment on soil conservation works through avoided damage to property and infrastructure and avoided clean-up costs.

  6. Evaluation of Anosognosia in Alzheimer's Disease Using the Symptoms of Early Dementia-11 Questionnaire (SED-11Q

    Directory of Open Access Journals (Sweden)

    Yohko Maki

    2013-10-01

    Full Text Available Aims: The objective is to propose a brief method to evaluate anosognosia in Alzheimer's disease (AD using the Symptoms of Early Dementia-11 Questionnaire (SED-11Q, a short informant-based screening questionnaire for identifying dementia. Methods: The participants were 107 elderly individuals: 13 with a Clinical Dementia Rating (CDR of 0.5, 73 with mild AD of CDR 1, and 21 with moderate AD of CDR 2. The patients and caregivers answered the SED-11Q independently, and the degree of discrepancy indicated the severity of anosognosia. Results: The scores were as follows: caregiver scores were 2.46 ± 1.85 (mean ± SD in CDR 0.5, 6.36 ± 3.02 in CDR 1, and 9.00 ± 1.14 in CDR 2; patient scores were 2.00 ± 1.78, 2.55 ± 2.33, and 1.33 ± 2.46, respectively. Discrepancy was 0.46 ± 1.61, 3.81 ± 3.95, and 7.67 ± 2.87, respectively, and the caregiver assessments were significantly higher than the patient assessments in CDR 1 and CDR 2 (p Conclusion: The SED-11Q serves a dual purpose: caregiver assessment is useful for the screening of dementia, and any discrepancy between the patient and the caregiver assessment is considered as an indication of the severity of anosognosia; this can be informative for caregivers and essential for successful care.

  7. MarsSedEx I and II: Experimental investigation of gravity effects on sedimentation on Mars

    Science.gov (United States)

    Kuhn, N. J.; Kuhn, B.; Gartmann, A.

    2014-12-01

    Sorting of sedimentary rocks is a proxy for the environmental conditions at the time of deposition, in particular the runoff that moved and deposited the material forming the rocks. Settling of sediment is strongly influenced by the gravity of a planetary body. As a consequence, sorting of a sedimentary rock varies with gravity for a given depth and velocity of surface runoff. Theoretical considerations for spheres indicate that sorting is less uniform on Mars than on Earth for runoff of identical depth. The effects of gravity on flow hydraulics limit the use of common, semi-empirical models developed to simulate particle settling in terrestrial environments, on Mars. Assessing sedimentation patterns on Mars, aimed at identifying strata potentially hosting traces of life, is potentially affected by such uncertainties. Using first-principle approaches, e.g. through Computational Fluid Dynamics, for calculating settling velocities on other planetary bodies requires a large effort and is limited by the values of boundary conditions, e.g. the shape of the particle. The degree of uncertainty resulting from the differences in gravity on Earth and Mars was therefore tested during three reduced-gravity flights, the MarsSedEx I and II missions, conducted in November 2012 and 2013. Nine types of sediment, ranging in size, shape and density were tested in custom-designed settling tubes during parabolas of Martian gravity lasting 20 to 25 seconds. Based on the observed settling velocities, the uncertainties of empirical relationships developed on Earth to assess particle settling on Mars are discussed. In addition, the potential effects of reduced gravity on patterns of erosion, transport and sorting of sediment, including the implications for identifying strata bearing traces of past life on are examined.

  8. THE NATURE OF EXTREMELY RED H - [4.5] > 4 GALAXIES REVEALED WITH SEDS AND CANDELS

    Energy Technology Data Exchange (ETDEWEB)

    Caputi, K. I.; Dunlop, J. S.; McLure, R. J.; Cirasuolo, M. [SUPA, Institute for Astronomy, The University of Edinburgh, Royal Observatory, Edinburgh EH9 3HJ (United Kingdom); Huang, J.-S.; Fazio, G. G.; Ashby, M. L. N. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Castellano, M.; Fontana, A. [INAF-Osservatorio Astronomico di Roma, Via Frascati 33, I-00040 Monteporzio (Italy); Almaini, O. [School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom); Bell, E. F. [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 48109 (United States); Dickinson, M. [National Optical Astronomy Observatory, 950 North Cherry Avenue, Tucson, AZ 85719 (United States); Donley, J. L.; Ferguson, H. C.; Grogin, N. A.; Koekemoer, A. M. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Faber, S. M.; Kocevski, D. D.; Koo, D. C. [University of California Observatories/Lick Observatory, University of California, Santa Cruz, CA 95064 (United States); Giavalisco, M., E-mail: karina@astro.rug.nl [Department of Astronomy, University of Massachusetts, Amherst, MA 01003 (United States); and others

    2012-05-01

    We have analyzed a sample of 25 extremely red H - [4.5] > 4 galaxies, selected using 4.5 {mu}m data from the Spitzer SEDS survey and deep H-band data from the Hubble Space Telescope CANDELS survey, over {approx}180 arcmin{sup 2} of the UKIDSS Ultra-Deep Survey field. Our aim is to investigate the nature of this rare population of mid-infrared (mid-IR) sources that display such extreme near-to-mid-IR colors. Using up to 17-band photometry (U through 8.0 {mu}m), we have studied in detail their spectral energy distributions, including possible degeneracies in the photometric redshift/internal extinction (z{sub phot}-A{sub V} ) plane. Our sample appears to include sources of very different nature. Between 45% and 75% of them are dust-obscured, massive galaxies at 3 < z{sub phot} < 5. All of the 24 {mu}m detected sources in our sample are in this category. Two of these have S(24 {mu}m)>300 {mu}Jy, which at 3 < z{sub phot} < 5 suggests that they probably host a dust-obscured active galactic nucleus. Our sample also contains four highly obscured (A{sub V} > 5) sources at z{sub phot} < 1. Finally, we analyze in detail two z{sub phot} {approx} 6 galaxy candidates, and discuss their plausibility and implications. Overall, our red galaxy sample contains the tip of the iceberg of a larger population of z > 3 galaxies to be discovered with the future James Webb Space Telescope.

  9. Evaluations of gonad and fetal doses for diagnostic radiology.

    Science.gov (United States)

    Tung, C J; Tsai, H Y

    1999-07-01

    A national survey of patient doses for diagnostic radiology was planned in the Republic of China. We performed a pilot study for this survey to develop a protocol of the dose assessments. Entrance skin doses and organ (including ovary, testicle and uterus) doses were measured by thermoluminescent dosimeters and calculated by means of Monte Carlo simulations for several diagnostic procedures. We derived a formula and used the RadComp software for the computation of entrance skin doses. This formula involves several factors, such as kVp, mAs, the focus-to-skin-distance and aluminum filtration. RadComp software was applied to obtain free-air entrance exposures which were converted to entrance skin doses by considering the backscattering radiation from the body. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom for several diagnostic examinations. Genetically significant doses were calculated from ovary and testicle doses for the evaluation of hereditary effects. Embryo/fetal doses were determined from the uterine doses by considering the increase in uterus size with gestational age. We found that the patient doses studied in this work were all below the reference doses recommended by the National Radiological Protection Board of the U.K.

  10. Entrance C - New Automatic Number Plate Recognition System

    CERN Multimedia

    2013-01-01

    Entrance C (Satigny) is now equipped with a latest-generation Automatic Number Plate Recognition (ANPR) system and a fast-action road gate.   During the month of August, Entrance C will be continuously open from 7.00 a.m. to 7.00 p.m. (working days only). The security guards will open the gate as usual from 7.00 a.m. to 9.00 a.m. and from 5.00 p.m. to 7.00 p.m. For the rest of the working day (9.00 a.m. to 5.00 p.m.) the gate will operate automatically. Please observe the following points:       Stop at the STOP sign on the ground     Position yourself next to the card reader for optimal recognition     Motorcyclists must use their CERN card     Cyclists may not activate the gate and should use the bicycle turnstile     Keep a safe distance from the vehicle in front of you   If access is denied, please check that your vehicle regist...

  11. Heat transfer to liquid sodium in the thermal entrance region

    International Nuclear Information System (INIS)

    Qiu, R.

    1981-01-01

    It is well known that the convective heat transfer in the regions of duct systems where the thermal boundary layers are not yet established can be far superior to heat transfer in the fully developed regions. A quantitative understanding of heat transfer in the thermal entrance region is essential in designing high heat-flux nuclear reactors. More specifically, if the thermal boundary layers have not been fully established in the system, the forced-convection relations for the fully developed regions cannot be used to predict the heat transfer characteristics. The present work is characterized by the following: 1. The behaviours in the thermal entrance region have been examined more completely. 2. To obtain a higher accuracy of analyses, in present study the method of SPARROW et al. for pipe was improved for annulus by utilizing a finite difference technique. Furthermore, an asymptotic solution was developed. 3. This is, in our knowledge, the first experimental investigation about the thermal development effect on turbulent heat transfer from rod element to liquid sodium in annulus with fully developed flow. (MDC)

  12. Spatially resolved star formation and dust attenuation in Mrk 848: Comparison of the integral field spectra and the UV-to-IR SED

    Science.gov (United States)

    Yuan, Fang-Ting; Argudo-Fernández, María; Shen, Shiyin; Hao, Lei; Jiang, Chunyan; Yin, Jun; Boquien, Médéric; Lin, Lihwai

    2018-05-01

    We investigate the star formation history and the dust attenuation in the galaxy merger Mrk 848. Thanks to the multiwavelength photometry from the ultraviolet (UV) to the infrared (IR), and MaNGA's integral field spectroscopy, we are able to study this merger in a detailed way. We divide the whole merger into the core and tail regions, and fit both the optical spectrum and the multi-band spectral energy distribution (SED) to models to obtain the star formation properties for each region respectively. We find that the color excess of stars in the galaxy E(B-V)sSED measured with the multi-band SED fitting is consistent with that estimated both from the infrared excess (the ratio of IR to UV flux) and from the slope of the UV continuum. Furthermore, the reliability of the E(B-V)sSED is examined with a set of mock SEDs, showing that the dust attenuation of the stars can be well constrained by the UV-to-IR broadband SED fitting. The dust attenuation obtained from optical continuum E(B-V)sspec is only about half of E(B-V)sSED. The ratio of the E(B-V)sspec to the E(B-V)g obtained from the Balmer decrement is consistent with the local value (around 0.5). The difference between the results from the UV-to-IR data and the optical data is consistent with the picture that younger stellar populations are attenuated by an extra dust component from the birth clouds compared to older stellar populations which are only attenuated by the diffuse dust. Both with the UV-to-IR SED fitting and the spectral fitting, we find that there is a starburst younger than 100 Myr in one of the two core regions, consistent with the scenario that the interaction-induced gas inflow can enhance the star formation in the center of galaxies.

  13. Comparison of programmed and cabled re-entrance systems. Elaboration of cabled re-entrance system for a CII 90.40

    International Nuclear Information System (INIS)

    Perraudeau, Jean

    1976-01-01

    The objective of this research thesis is to study problems related to re-entrance, and, more particularly, to study a re-entrance system for a CII 90.40 computer. Such a system can be realised under a programmed or cabled form, and both approaches are described and compared. A generalisation of this comparison is briefly proposed. As the computer already possesses a programmed re-entrance system, the author focuses on the study of the cabled re-entrance system which results in an improvement of performance and possibilities provided by this computer, particularly for its use in real time. The design, realisation and development of such a cabled system are reported. A first part reports a theoretical study on re-entrance (definition, problems, applications), a presentation of the computer, a description of the programmed re-entrance system, a presentation of the principle of the chosen cabled re-entrance system, a definition of the structure and operating mode of the cabled pile and a description of its various components, and a flowchart analysis of function execution. The second part reports the practical realisation: definition, technological overview, technology used in the cabled pile, sequencing and multiplexing principle, impulse transmission, logical layouts, and circuit adjustments. The third part presents practical example. An assessment and perspectives are finally discussed

  14. Dose in conventional radiography

    International Nuclear Information System (INIS)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  15. Inversion of Flow Depth and Speed from Tsunami Deposits using TsuSedMod

    Science.gov (United States)

    Spiske, M.; Weiss, R.; Roskosch, J.; Bahlburg, H.

    2008-12-01

    The global evolution of a tsunami wave train can be expressed by the sum of local effects along a tsunami- wave beam. The near-shore evolution of tsunami is very complex as the waves interact with the sea-bottom sediments. Filtered through offshore and onshore erosion and deposition, this evolution is recorded in the coastal area by topographical changes, local erosion and tsunami deposits. Recordable sedimentary on-site features include grain-size distributions and horizontal thickness trends. Immediately after an event, indicators of flow depth and run up extent, such as water marks on buildings and vegetation, debris and plastic bags caught in trees and swash lines, can be measured in the field. A direct measurement of the overland flow velocity is usually not possible. However, regarding recent tsunami events, videos of surveillance cameras or witness accounts helped to estimate the characteristics of overland flow. For historical and paleotsunami events such information is not directly available. Jaffe & Gelfenbaum (2007) developed an inversion model (TsuSedMod) to estimate flow depth and speed based upon the grain-size distribution and the thickness of onshore tsunami sediments. This model assumes a steady distribution of sediment in the water column, for which the appication of the Rouse equation is possible. Further simplifications, especially concerning the turbulence structure, are based on the mixing- length theory by Prandtl, the standard approximation in physical sedimentology. We calculated flow depths for sediments left behind by the 2004 Sumatra-Tsunami in India and Kenya (Weiss & Bahlburg, 2006; Bahlburg & Weiss, 2007) and by the 2006 Java-Tsunami on Java (Piepenbreier et al., 2007), using the model of Jaffe and Gelfenbaum (2007). Estimated flow depth were compared with measured data to extend the validation procedure. This extension is needed to gain confidence and understanding before the next step is taken to compute the near

  16. Effects of Magnetic Particles Entrance Arrangements on Mixing Efficiency of a Magnetic Bead Micromixer

    Institute of Scientific and Technical Information of China (English)

    Reza Kamali; Seyed Alireza Shekoohi; Alireza Binesh

    2014-01-01

    In this study, a computer code is developed to numerically investigate a magnetic bead micromixer under different conditions. The micromixer consists of a microchannel and numerous micro magnetic particles which enter the micromixer by fluid flows and are actuated by an alternating magnetic field normal to the main flow. An important feature of micromixer which is not considered before by researchers is the particle entrance arrangement into the micromixer. This parameter could effectively affect the micromixer efficiency. There are two general micro magnetic particle entrance arrangements in magnetic bead micromixers: determined position entrance and random position entrance. In the case of determined position entrances, micro magnetic particles enter the micromixer at specific positions of entrance cross section. However, in a random position entrance,particles enter the microchannel with no order. In this study mixing efficiencies of identical magnetic bead micromixers which only differ in particle entrance arrangement are numerically investigated and compared.The results reported in this paper illustrate that the prepared computer code can be one of the most powerful and beneficial tools for the magnetic bead micromixer performance analysis. In addition, the results show that some features of the magnetic bead micromixer are strongly affected by the entrance arrangement of the particles.

  17. A Comparative Study of Entrance in Traditional and Contemporary Houses of Iran

    Directory of Open Access Journals (Sweden)

    Ramin Dehbandi

    2017-12-01

    Full Text Available In contemporary houses in Iran, because of changes in the methods of designing and building houses, importance of entrance reduced to such level that now in contemporary houses entrance is just a door. Entrance correlates indoor safe space of house and outdoors. It`s importance lays in controlling entry, exit, territory and hierarchy. Since house owners were satisfied with traditional form of entrance, it is a good idea to learn from them in designing new entrances. The purpose of this research is to find a way for designing appropriate entrances for Iranian contemporary houses. To do this at first 40 traditional houses and 40 contemporary houses in Isfahan and Kashan were selected. These two cities are from margin of desert and the origin of traditional houses of Iran. Analysis showed that blockage of visual and phonic relation, creating a space between outdoor public space and indoor private space, creating access patterns to internal spaces and traits that separate in and out were the most significant properties of traditional entrances. All these traits are ignored in contemporary entrances. Suggestions made for design include creating public meeting space in yard and creating a separate entrance space for each house in apartments.

  18. Comparison of entrance exposure and signal-to-noise ratio between an SBDX prototype and a wide-beam cardiac angiographic system

    International Nuclear Information System (INIS)

    Speidel, Michael A.; Wilfley, Brian P.; Star-Lack, Josh M.; Heanue, Joseph A.; Betts, Timothy D.; Van Lysel, Michael S.

    2006-01-01

    The scanning-beam digital x-ray (SBDX) system uses an inverse geometry, narrow x-ray beam, and a 2-mm thick CdTe detector to improve the dose efficiency of the coronary angiographic procedure. Entrance exposure and large-area iodine signal-to-noise ratio (SNR) were measured with the SBDX prototype and compared to that of a clinical cardiac interventional system with image intensifier (II) and charge coupled device (CCD) camera (Philips H5000, MRC-200 x-ray tube, 72 kWp max). Phantoms were 18.6-35.0 cm acrylic with an iohexol-equivalent disk placed at midthickness (35 mg/cm 2 iodine radiographic density). Imaging was performed at 15 frame/s, with the disk at mechanical isocenter and an 11-cm object-plane field width. The II/CCD system was operated in cine mode with automatic exposure control. With the SBDX prototype at maximum x-ray output (120 kVp, 24.3 kWp), the SBDX SNR was 107%-69% of the II/CCD SNR, depending on phantom thickness, and the SBDX entrance exposure rate was 10.7-9.3 R/min (9.4-8.2 cGy/min air kerma). For phantoms where an equal-kVp imaging comparison was possible (≥23.3 cm), the SBDX SNR ranged from 47% to 69% of the II/CCD SNR while delivering 6% to 9% of the II/CCD entrance exposure rate. From these measurements it was determined that the relative SBDX entrance exposure at equal SNR would be 31%-16%. Results were consistent with a model for relative entrance exposure at equal SNR, which predicted a 3-7 times reduction in entrance exposure due to SBDX's comparatively low scatter fraction (5.5%-8.1% measured, including off-focus radiation), high detector detective quantum efficiency (66%-73%, measured from 70 to 120 kVp), and large entrance field area (1.7x-2.3x, for the same object-plane field width). With improvements to the system geometry, detector, and x-ray source, SBDX technology is projected to achieve conventional cine-quality SNR over a full range of patient thicknesses, with 5-10 times lower skin dose

  19. Entrance-channel effects in the population of superdeformed bands

    Energy Technology Data Exchange (ETDEWEB)

    Smith, G.; Haas, B.; Alderson, A.; Ali, I.; Beausang, C.W.; Bentley, M.A.; Dagnall, P.; Fallon, P.; de France, G.; Forsyth, P.D.; Huttmeier, U.; Romain, P.; Santos, D.; Twin, P.J.; Vivien, J.P. (Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 3BX (United Kingdom) Centre de Recherches Nucleaires, F-67037 Strasbourg CEDEX (France) Sciences and Engineering Research Council, Daresbury Laboratory, Warrington WA44AD (United Kingdom))

    1992-01-13

    In order to investigate whether entrance-channel effects influence the production of superdeformed nuclei, we have measured the yield of the yrast superdeformed band in {sup 152}Dy populated via nearly mass-symmetric ({sup 82}Se+{sup 74}Ge) and mass-asymmetric ({sup 48}Ca+{sup 108}Pd, {sup 36}S+{sup 120}Sn) fusion reactions leading to the same compound nucleus at similar excitation energies and angular momenta. Large differences in the relative intensity of the band compared with the total yield of the nucleus are observed in the various reactions. This effect indicates that the competition between fission and neutron evaporation is affected by the mode of formation of the fusing system.

  20. Fiber optic sensor system for entrance areas monitoring

    Science.gov (United States)

    Fajkus, Marcel; Nedoma, Jan; Kepak, Stanislav; Cubik, Jakub; Jargus, Jan; Zboril, Ondřej; Martinek, Radek; Vasinek, Vladimir

    2017-10-01

    Authors of this article present the fiber-optic system based on fiber Bragg gratings (FBGs) which are used to secure the entrance areas such as buildings, halls, warehouses, etc. The system uses the specially encapsulated sensory array of fiber Bragg gratings which are implemented into the floor or on the floor and allows for monitoring the area of 1 m2 up to 100 m2 depending on the number of FBG sensors. The sensory array is characterized by immunity to electromagnetic interference (EMI), passivity regarding electrical power supply, the possibility of remote evaluation (up to units of km) and high sensitivity. Proposed sensor system has detection capability greater than 99 % and furthermore, provides information about the weight load to an accuracy of +/- 5 kg. The concept has been tested in a real environment within the test polygon for several weeks. As the reference devices, we used the CCTV (Closed Circuit Television).

  1. Calculation of bedload transport in Swiss mountain rivers using the model sedFlow: proof of concept

    Directory of Open Access Journals (Sweden)

    F. U. M. Heimann

    2015-01-01

    Full Text Available Fully validated numerical models specifically designed for simulating bedload transport dynamics in mountain streams are rare. In this study, the recently developed modelling tool sedFlow has been applied to simulate bedload transport in the Swiss mountain rivers Kleine Emme and Brenno. It is shown that sedFlow can be used to successfully reproduce observations from historic bedload transport events with plausible parameter set-ups, meaning that calibration parameters are only varied within ranges of uncertainty that have been pre-determined either by previous research or by field observations in the simulated study reaches. In the Brenno river, the spatial distribution of total transport volumes has been reproduced with a Nash–Sutcliffe goodness of fit of 0.733; this relatively low value is partially due to anthropogenic extraction of sediment that was not considered. In the Kleine Emme river, the spatial distribution of total transport volumes has been reproduced with a goodness of fit of 0.949. The simulation results shed light on the difficulties that arise with traditional flow-resistance estimation methods when macro-roughness is present. In addition, our results demonstrate that greatly simplified hydraulic routing schemes, such as kinematic wave or uniform discharge approaches, are probably sufficient for a good representation of bedload transport processes in reach-scale simulations of steep mountain streams. The influence of different parameters on simulation results is semi-quantitatively evaluated in a simple sensitivity study. This proof-of-concept study demonstrates the usefulness of sedFlow for a range of practical applications in alpine mountain streams.

  2. Reduction of entrance surface dose depending on shielding methods for panoramagraphy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jung Hyun; Han, DongKyoon [Dept. of Radiological Science, The Graduate School, Eulji University, Sungnam (Korea, Republic of); Kim, Sung Chul [Dept. of Radiological, Science Gachon, University, Incheon (Korea, Republic of)

    2015-09-15

    Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase. This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs.

  3. determination of entrance skin dose from diagnostic x-ray of human

    African Journals Online (AJOL)

    In medicine, ionizing radiation is used for two main purposes; diagnosis and therapy. ... to ionizing radiation include, direct chromosomal transformation, indirect free-radical ... Investigation on the effect of exposure factors on the quality of the.

  4. Contribution to adaptive radiotherapy by systematic analysis of the entrance fluence and exit patient dose

    International Nuclear Information System (INIS)

    Celi, Sofia

    2016-01-01

    Modern radiation therapy combines complex techniques and personalized treatments, with the risk that certain evolutions and errors occurring during the course of the treatment might go unnoticed. These fluctuations may cause great damage to the health of the patient. In this perspective, we worked on the potential of a transit in vivo dosimetry system for continuous monitoring of the patient and, hereafter, adaptive radiotherapy. Our clinical experience and feasibility testing determined the main lines of work: automation and simplification of the results analysis method. The developments included the creation of a golden data library and a series of root cause analyzes, allowing us to strengthen the accuracy of the system, to enhance the automation of the setup and to identify tracks for an efficient analysis of the results and for the creation of additional analytical tools to facilitate the monitoring and adaptation of the treatments in clinical routine [fr

  5. Dose load at oral entrance and injection of radionuclides in human organism

    International Nuclear Information System (INIS)

    Korkoshko, S.

    2000-01-01

    The main purpose of the given work is the determination of probability evaluation of risk of damage to a human organism from application of radiopharmaceuticals in diagnostics and therapy. The level of negligible risk divides the area of optimization of risk and the area of unconditional acceptable risk and equals to (1.0x10 6 ) for one year. (authors)

  6. Reduction of entrance surface dose depending on shielding methods for panoramagraphy

    International Nuclear Information System (INIS)

    Choi, Jung Hyun; Han, DongKyoon; Kim, Sung Chul

    2015-01-01

    Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase. This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs

  7. Paediatric doses from diagnostic radiology in Victoria

    International Nuclear Information System (INIS)

    Boal, T.J.; Cardillo, I.; Einsiedel, P.F.

    1998-01-01

    This study examines doses to paediatric patients from diagnostic radiology. Measurements were made at 29 hospitals and private radiology practices in the state of Victoria. Entrance skin doses in air were measured for the exposure factors used by hospital radiology departments and private radiology practices for a standard size 1, 5, 10 and 15 year old child, for the following procedures: chest AP/PA, lat; abdomen AP; pelvis AP; lumbar spine AP, lat; and skull AP, lat. There was a large range of doses for each particular procedure and age group. Factors contributing to the range of doses were identified. Guidance levels for paediatric radiology based on the third quartile value of the skin entrance doses have been recommended and are compared with guidance levels. Copyright (1998) Australasian Physical and Engineering Sciences in Medicine

  8. Proposals for Standardizing and Improving the Policy of Adding Points on the Entrance Exam

    Science.gov (United States)

    Yuhong, Deng

    2013-01-01

    This article reviews policies for adding points on the College Entrance Examination. It analyzes the rationales and specific implementation strategies of various policies for adding points on the entrance exam, as well as their advantages and pitfalls. Based on these observations and analysis, the author also offers policy recommendations on the…

  9. Heat transfer in the thermal entrance region of a circular tube with axial heat conduction

    International Nuclear Information System (INIS)

    Zhang Changquan.

    1985-01-01

    This paper recounts the effects of axial heat conduction and convective boundary conditions on the heat transfer in the thermal entrance region of a circular tube under uniform flow, and the corresponding calculation is made. It will be profitable for the heat transfer studies on the pipe entrance region of low Prandtl number (liquid metal), or flow of low Peclet number. (author)

  10. 50 CFR 25.53 - Establishment of single visit entrance fees.

    Science.gov (United States)

    2010-10-01

    ... fees. 25.53 Section 25.53 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM ADMINISTRATIVE PROVISIONS Fees and Charges § 25.53 Establishment of single visit entrance fees. Entrance fees established for single visit...

  11. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  12. 3C 279 IN OUTBURST IN 2015 JUNE: A BROADBAND SED STUDY BASED ON THE INTEGRAL DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Bottacini, Eugenio [W.W. Hansen Experimental Physics Laboratory and Kavli Institute for Particle Astrophysics and Cosmology, Stanford University (United States); Böttcher, Markus [Centre for Space Research, North-West University, Potchefstroom 2531 (South Africa); Pian, Elena [INAF, Istituto di Astrofisica Spaziale e Fisica Cosmica, via P. Gobetti 101, I-40129 Bologna (Italy); Collmar, Werner, E-mail: eugenio.bottacini@stanford.edu [Max-Planck-Institut für extraterrestrische Physik, Giessenbach, D-85748 Garching (Germany)

    2016-11-20

    Blazars radiate from radio through gamma-ray frequencies and thereby make ideal targets for multifrequency studies. Such studies allow the properties of the emitting jet to be constrained. 3C 279 is among the most notable blazars and therefore subject to extensive multifrequency campaigns. We report the results of a campaign ranging from near-IR to gamma-ray energies that targeted an outburst of 3C 279 in 2015 June. The campaign pivots around the detection in only 50 ks by INTEGRAL , whose IBIS/ISGRI data pin down the high-energy component of the spectral energy distribution (SED) between Swift -XRT data and Fermi -LAT data. The overall SED from near-IR to gamma rays can be well represented by either a leptonic or a lepto-hadronic radiation transfer model. Even though the data are equally well represented by the two models, their inferred parameters challenge the physical conditions in the jet. In fact, the leptonic model requires parameters with a magnetic field far below equipartition with the relativistic particle energy density. In contrast, equipartition may be achieved with the lepto-hadronic model, although this implies an extreme total jet power close to the Eddington luminosity.

  13. SedFoam-2.0: a 3-D two-phase flow numerical model for sediment transport

    Directory of Open Access Journals (Sweden)

    J. Chauchat

    2017-11-01

    Full Text Available In this paper, a three-dimensional two-phase flow solver, SedFoam-2.0, is presented for sediment transport applications. The solver is extended from twoPhaseEulerFoam available in the 2.1.0 release of the open-source CFD (computational fluid dynamics toolbox OpenFOAM. In this approach the sediment phase is modeled as a continuum, and constitutive laws have to be prescribed for the sediment stresses. In the proposed solver, two different intergranular stress models are implemented: the kinetic theory of granular flows and the dense granular flow rheology μ(I. For the fluid stress, laminar or turbulent flow regimes can be simulated and three different turbulence models are available for sediment transport: a simple mixing length model (one-dimensional configuration only, a k − ε, and a k − ω model. The numerical implementation is demonstrated on four test cases: sedimentation of suspended particles, laminar bed load, sheet flow, and scour at an apron. These test cases illustrate the capabilities of SedFoam-2.0 to deal with complex turbulent sediment transport problems with different combinations of intergranular stress and turbulence models.

  14. SedFoam-2.0: a 3-D two-phase flow numerical model for sediment transport

    Science.gov (United States)

    Chauchat, Julien; Cheng, Zhen; Nagel, Tim; Bonamy, Cyrille; Hsu, Tian-Jian

    2017-11-01

    In this paper, a three-dimensional two-phase flow solver, SedFoam-2.0, is presented for sediment transport applications. The solver is extended from twoPhaseEulerFoam available in the 2.1.0 release of the open-source CFD (computational fluid dynamics) toolbox OpenFOAM. In this approach the sediment phase is modeled as a continuum, and constitutive laws have to be prescribed for the sediment stresses. In the proposed solver, two different intergranular stress models are implemented: the kinetic theory of granular flows and the dense granular flow rheology μ(I). For the fluid stress, laminar or turbulent flow regimes can be simulated and three different turbulence models are available for sediment transport: a simple mixing length model (one-dimensional configuration only), a k - ɛ, and a k - ω model. The numerical implementation is demonstrated on four test cases: sedimentation of suspended particles, laminar bed load, sheet flow, and scour at an apron. These test cases illustrate the capabilities of SedFoam-2.0 to deal with complex turbulent sediment transport problems with different combinations of intergranular stress and turbulence models.

  15. The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose

    International Nuclear Information System (INIS)

    Beentjes, L.B.; Duijsings, J.H.

    1992-01-01

    The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a somatically significant dose, SSD. The reduction of the SED value to a SSD for the medical field due to this phenomenon is .6 for diagnostic radiology, .5 for nuclear medicine and .3 for radiotherapy. Also the extension to more organs at risk, which result in a larger number of weighting factors published by ICRP (IC91a) tends to lower the calculated effective doses. (author)

  16. Patient dose measurement and dose reduction in East Anglia (UK)

    International Nuclear Information System (INIS)

    Wade, J.P.; Goldstone, K.E.; Dendy, P.P.

    1995-01-01

    At the end of 1990 a programme of patient dose measurements was introduced as part of the quality assurance service already provided for X ray departments throughout the East Anglian Health Region (UK). Thermoluminescence dosemeters (TLDs) were used to measure over 1200 skin entrance surface doses for four common radiographic views in 33 hospitals in both the NHS and private sector. The four views were chosen to cover a wide range of equipment and techniques. The data collected have enabled Regional reference doses to be set which, for all views considered, fall below the National Radiological Protection Board (NRPB) Reference levels. In departments which exceeded reference levels, techniques were reviewed, improvements suggested and doses re-measured, in accordance with the recommended procedure for patient dose audit. A significant finding was that, given appropriate controls, X ray departments in the private sector could achieve the same acceptably low doses as NHS departments. (Author)

  17. Doses to patients and staff from endovascular treatment of abdominal aortic aneurysms - Preliminary results

    International Nuclear Information System (INIS)

    Bjoerklund, E.G.; Widmark, A.; Gjoelberg, T.; Bay, D.; Joergensen, J.J.; Staxrud, L.E.

    2001-01-01

    Patient radiation doses received during endovascular treatment of abdominal aortic aneurysms (AAA) can be significant and give rise to both deterministic and stochastic effects. Recording of dose-area product (DAP), fluoroscopy time and number of exposures together with calculations of effective dose, were performed for 8 patients. In addition, the entrance surface dose was measured for 3 of the patients. Typically, DAPs of 340 Gycm 2 , fluoroscopy times of 30 minutes and 310 exposures were obtained together with maximum entrance surface doses of 1,8 Gy and effective doses of 50 mSv. Finger doses to the staff performing the procedure were in the order of a few hundred μSv. Conversion factors (effective dose/DAP) and (maximum entrance surface does/DAP) of 0,61·10 -2 Gy/Gycm 2 and 0,15 mSv/Gycm 2 were obtained, respectively. (author)

  18. Entrance and Exit CSR Impedance for Non-Ultrarelativistic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Li, Rui; Tsai, Cheng Ying [SLAC National Accelerator Lab., Menlo Park, CA (United States); Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States)

    2017-05-01

    For a high-brightness electron beam being transported through beamlines involving bending systems, the coherent synchrotron radiation (CSR) and longitudinal space charge (LSC) interaction could often cause microbunching instability. The semi-analytical Vlasov solver for microbunching gain* depends on the impedances for the relevant collective effects. The existing results for CSR impedances are usually obtained for the ultrarelativistic limit. To extend the microbunching analysis to cases of low energies, such as the case of an ERL merger, or to density modulations at extremely small wavelength, it is necessary to extend the impedance analysis to the non-ultrarelativistic regime. In this study, we present the impedance analysis for the transient CSR interaction in the non-ultrarelativistic regime, for transients including both entrance to and exit from a magnetic dipole. These impedance results will be compared to their ultra-relativistic counterparts**, and the corresponding wakefield obtained from the impedance for low-energy beams will be compared with the existing results of transient CSR wakefield for general beam energies***.

  19. Measuring hand hygiene compliance rates at hospital entrances.

    Science.gov (United States)

    Vaidotas, Marina; Yokota, Paula Kiyomi Onaga; Marra, Alexandre R; Camargo, Thiago Zinsly Sampaio; Victor, Elivane da Silva; Gysi, Deisy Morselli; Leal, Flavio; Santos, Oscar Fernando Pavão dos; Edmond, Michael B

    2015-07-01

    Despite the importance of hand hygiene in the health care setting, there are no studies evaluating hand hygiene compliance at hospital entrances. The study was prospectively performed over a 33-week period from March 30, 2014-November 15, 2014, to evaluate hand hygiene compliance in 2 hospital reception areas. We compared electronic handwash counters with the application of radiofrequency identification (GOJO SMARTLINK) (electronic observer) that counts each activation of alcohol gel dispensers to direct observation (human observer) via remote review of video surveillance. We found low hand hygiene compliance rates of 2.2% (99/4,412) and 1.7% (140/8,277), respectively, at reception areas A and D, detected by direct observation. Using the electronic observer, we measured rates of 17% (15,624/91,724) and 7.1% (51,605/730,357) at reception areas A and D, respectively. For the overall time period of simultaneous electronic and human observation, the human observer captured 1% of the hand hygiene episodes detected by the electronic observer. Our study showed very low hand hygiene compliance in hospital reception areas, and we found an electronic hand hygiene system to be a useful method to monitor hand hygiene compliance. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. An Extra Push from Entrance-Channel Effects

    International Nuclear Information System (INIS)

    Grar, Nabila; Rowley, Neil

    2006-01-01

    The fusion probability for heavy symmetric systems is known to show certain very specific features. Apart from the large variance of the fusion barrier distribution, it is found that the energy at which the s-wave transmission is 0.5 is shifted to an energy significantly higher than the nominal (e.g. Bass) Coulomb barrier. This last feature is referred to in the literature as the 'extra push' effect. Many models have been devised to explain the origin of these findings. It is worth noting, however, that despite the extra push, the capture cross section is still greatly enhanced at the very lowest energies. This fact cannot be explained within the framework of macroscopic theories involving conditional saddle points or frictional forces. We have performed full coupled-channel calculations for heavy, symmetric systems treating correctly the long-range Coulomb excitations of the collective quadrupole- and octupole-phonon states in the target and projectile. The results obtained show that the extra push and the overall shape of the fusion probability are simply explained by these entrance-channel effects

  1. Novel spherical hohlraum with cylindrical laser entrance holes and shields

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Ke [Institute of Applied Physics and Computational Mathematics, Beijing 100088 (China); Center for Applied Physics and Technology, Peking University, Beijing 100871 (China); Zheng, Wudi [Institute of Applied Physics and Computational Mathematics, Beijing 100088 (China)

    2014-09-15

    Our recent works [K. Lan et al., Phys. Plasmas 21, 010704 (2014); K. Lan et al., Phys. Plasmas 21, 052704 (2014)] have shown that the octahedral spherical hohlraums are superior to the cylindrical hohlraums in both higher symmetry during the capsule implosion and lower backscatter without supplementary technology. However, both the coupling efficiency from the drive laser energy to the capsule and the capsule symmetry decrease remarkably when larger laser entrance holes (LEHs) are used. In addition, the laser beams injected at angles > 45° transport close to the hohlraum wall, thus the wall blowoff causes the LEH to close faster and results in strong laser plasma interactions inside the spherical hohlraums. In this letter, we propose a novel octahedral hohlraum with LEH shields and cylindrical LEHs to alleviate these problems. From our theoretical study, with the LEH shields, the laser coupling efficiency is significantly increased and the capsule symmetry is remarkably improved in the spherical hohlraums. The cylindrical LEHs take advantage of the cylindrical hohlraum near the LEH and mitigate the influence of the blowoff on laser transport inside a spherical hohlraum. The cylindrical LEHs can also be applied to the rugby and elliptical hohlraums.

  2. Novel spherical hohlraum with cylindrical laser entrance holes and shields

    International Nuclear Information System (INIS)

    Lan, Ke; Zheng, Wudi

    2014-01-01

    Our recent works [K. Lan et al., Phys. Plasmas 21, 010704 (2014); K. Lan et al., Phys. Plasmas 21, 052704 (2014)] have shown that the octahedral spherical hohlraums are superior to the cylindrical hohlraums in both higher symmetry during the capsule implosion and lower backscatter without supplementary technology. However, both the coupling efficiency from the drive laser energy to the capsule and the capsule symmetry decrease remarkably when larger laser entrance holes (LEHs) are used. In addition, the laser beams injected at angles > 45° transport close to the hohlraum wall, thus the wall blowoff causes the LEH to close faster and results in strong laser plasma interactions inside the spherical hohlraums. In this letter, we propose a novel octahedral hohlraum with LEH shields and cylindrical LEHs to alleviate these problems. From our theoretical study, with the LEH shields, the laser coupling efficiency is significantly increased and the capsule symmetry is remarkably improved in the spherical hohlraums. The cylindrical LEHs take advantage of the cylindrical hohlraum near the LEH and mitigate the influence of the blowoff on laser transport inside a spherical hohlraum. The cylindrical LEHs can also be applied to the rugby and elliptical hohlraums

  3. Preequilibrium GDR excitation and entrance channel angular momentum effects

    International Nuclear Information System (INIS)

    Sandoli, M.; Campajola, L.; De Rosa, A.; D'Onofrio, A.; La Commara, M.; Ordine, A.; Pierroutsakou, D.; Roca, V.; Romano, M.; Romoli, M.; Terrasi, F.; Trotta, M.; Cardella, G.; Papa, M.; Pappalardo, G.; Rizzo, F.; Alamanos, N.; Auger, F.; Gillibert, A.

    1997-01-01

    The energy spectra of the γ-rays emitted in the 35 Cl+ 92 Mo reaction at incident energy E=260 MeV were measured in coincidence with the ejectiles produced in dissipative reaction events. The cumulative energy spectrum of the γ-rays coming from the decay of the ejectiles was calculated within the statistical model and its comparison to the experimental spectrum evidences an excess in the data for E γ =8 to 12 MeV. Such an excess, fitted with a Lorentz curve, is attributed to the preequilibrium GDR γ-decay of the intermediate dinuclear system. The centroid energy of the Lorentz curve corresponds to a dipole oscillation along the symmetry axis of the system and its width is found to be comparable to that of the ground state GDR low energy component of the deformed dinucleus. The small quantal dispersion Δl=(10.3±0.1)ℎ of the entrance channel angular momentum, determined by analysing the dissipative fragment angular distribution in the framework of the Strutinsky model, is suggested to limit the broadening of the preequilibrium GDR width. (orig.)

  4. Radioactive substances detection at solid waste incinerators entrance

    International Nuclear Information System (INIS)

    Bourjat, V.; Carre, J.; Perrier-Rosset, A.

    2001-01-01

    SYCTOM'S incinerators, operated by TIRU will soon be fitted out with radioactivity control systems to prevent entrance of radioactive waste. Such implementation aims at reducing health risks due to exposition of operators working in incinerators or in sites receiving incineration residues. Radioactive wastes are supposed to be well managed: in the case where the radioactive elements period is short, they have to be stored for a precise time; in all the other cases, a statutory organism dealing with radioactive waste (ANDRA) has to take charge of them. Meanwhile they may arrived in incinerators by mistake. It's difficult to regulate radioactivity control systems for technical reasons; the measured values can be really different from these in the truck because of radiation decreasing; moreover it can't be correlated to an activity, hence it can't be compared to exemption values or to the limits that characterise a radioactive substance. It can explain why regulated documents don't indicate the way to fix alarm threshold. Implementing such a system is not sufficient: when the alarm sound, the following steps can be applied: checking the missing of interference, potential truck return to sender, putting the truck in quarantine, information of authorities and main actors, calling on a specialize company to locate, extract and package the radiation source, storage of this source and spectrometric analysis to identify and quantify the radioactive elements in order to determinate its way of elimination. (authors)

  5. Application of personal computer to development of entrance management system for radiating facilities

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Hirai, Shouji

    1989-01-01

    The report describes a system for managing the entrance and exit of personnel to radiating facilities. A personal computer is applied to its development. Major features of the system is outlined first. The computer is connected to the gate and two magnetic card readers provided at the gate. The gate, which is installed at the entrance to a room under control, opens only for those who have a valid card. The entrance-exit management program developed is described next. The following three files are used: ID master file (random file of the magnetic card number, name, qualification, etc., of each card carrier), entrance-exit management file (random file of time of entrance/exit, etc., updated everyday), and entrance-exit record file (sequential file of card number, name, date, etc.), which are stored on floppy disks. A display is provided to show various lists including a list of workers currently in the room and a list of workers who left the room at earlier times of the day. This system is useful for entrance management of a relatively small facility. Though small in required cost, it requires only a few operators to perform effective personnel management. (N.K.)

  6. Vehicle operation characteristic under different ramp entrance conditions in underground road: Analysis, simulation and modelling

    Science.gov (United States)

    Yao, Qiming; Liu, Shuo; Liu, Yang

    2018-05-01

    An experimental design was used to study the vehicle operation characteristics of different ramp entrance conditions in underground road. With driving simulator, the experimental scenarios include left or right ramp with first, second and third service level, respectively, to collect vehicle speed, acceleration, lateral displacement and location information at the ramp entrance section. By using paired t-test and ANOVA, the influence factors of vehicle operating characteristics are studied. The result shows that effects of ramp layout and mainline traffic environment on vehicle operation characteristics are significant. The regression model of vehicle traveling distance on acceleration lane is established. Suggestions are made for ramp entrance design of underground road.

  7. The patient dose survey and dose reduction in diagnostic radiology

    International Nuclear Information System (INIS)

    Dang Thanh Luong; Duong Van Vinh; Ha Ngoc Thach

    2000-01-01

    This paper presented the results of the patient dose survey in some hospitals in Hanoi from 1995 to 1997. The main investigated types of the X-ray examination were: Chest PA, LAT; Skull PA/AP, LAT; Lumbar spine AP, LAT; and Pelvis AP. The fluctuation of the entrance surface doses (ESD) was too large, even in the same type of X-ray examination and X-ray facility. It was found that the ratio of maximum and minimum ESD were ranged from 1.5 to 18. The mean values of ESD for chest and skull were higher than CEC recommended values, while the mean values of lumbar spine and pelvis were smaller than that of CEC recommended values. The result of dose intercomparison was also reported. Some methods of dose reduction were applied for improving the patient dose in X-ray departments such as a high kV technique, high sensitive screen-film combination. (author)

  8. Comparing data of terrestrial LiDAR and UAV (photogrammetric) in the context of the project "SedAlp"

    Science.gov (United States)

    Abel, Judith; Wegner, Kerstin; Haas, Florian; Heckmann, Tobias; Becht, Michael

    2014-05-01

    The project "SedAlp" (Sediment management in Alpine basins: integrating sediment continuum, risk mitigation and hydropower) concentrates on problems and approaches related to sediment transfer in the alpine region and is embedded in the European transnational cooperation program "Alpine Space". The catholic University Eichstätt-Ingolstadt contributes the German part to this project on behalf of the Bavarian Environment Agency and in collaboration with the Authority of Water Resources Weilheim. The area of interest is the river Isar between the Sylvenstein reservoir and the city of Bad Tölz, Bavaria, Germany. The main aim of the activities is to quantify the transfer of sediments from the tributary catchments to the river Isar, specifically in light of the fact that the construction of the Sylvenstein reservoir in the mid 1950ies has created a barrier to longitudinal sediment transfer, thus heavily impacting the sediment budget and morphodynamics of the Isar reaches downstream. Moreover, the further development of artificially inserted gravel deposits and the effect of dismantling reinforcement structures at the river banks need investigation. Therefore, the dynamics of alluvial fans and gravel bars in the areas of confluence of tributary torrents are monitored using multitemporal surveys with terrestrial laserscanners and drone-based imagery. The latter is used both for the generation of high-resolution digital elevation models and for the mapping of changes in comparison to historical aerial photos. This study focuses on a comparison of TLS and UAV-based photogrammetric digital elevation models in order to highlight advantages and disadvantages of the two methods in relation to the SedAlp-specific research problems. It is shown that UAV-based elevation models are highly accurate alternatives to TLS-based models; due to their favourable acquisition geometry with respect to the topography in floodplain areas, and their large areal coverage, their use is seen as

  9. The accumulation of a chemical cue: nest-entrance trail in the German yellowjacket, Vespula germanica

    Science.gov (United States)

    Jandt, Jennifer M.; Curry, Christine; Hemauer, Sarah; Jeanne, Robert L.

    2005-05-01

    Vespine wasps have been shown to deposit an attractive chemical in the nest entrance. Foragers use this to help locate the nest when returning to it. We determined how many individuals need to track (pass through) the entrance before the chemical is recognized. We found a logistic response as the number of tracks increased. At 200 tracks and above there was a 75 90% positive response rate to the chemical. We found no evidence of trail-marking behavior performed by foragers inside the nest entrance. We conclude that the trail is not an evolved signal, but is a cue composed of an accumulation of hydrocarbons deposited from the legs or feet of workers as they walk on a substrate. This is the first quantitative measurement of the attractiveness of the nest-entrance chemical in a social wasp.

  10. Effect of private tutoring on university entrance examination performance in Turkey

    OpenAIRE

    Tansel, Aysit; Bircan, Fatma

    2005-01-01

    There is an excess demand for university education in Turkey. Highly competitive university entrance examination which rations the available places at university programs is very central to the lives of young people. In order to increase the chances of success of their children in the university entrance examination parents spend large sums of money on private tutoring (dersane) of their children. In this study, we investigate the factors that determine participation in private tutoring and t...

  11. On the border. Value and function of museum’s entrance hall and its symbolic meaning

    Directory of Open Access Journals (Sweden)

    Lucia Tarantino

    2013-11-01

    Full Text Available The text aims to analyze the museum entrance halls, mainly from the point of view of the growing phenomenon of mass tourism. The entrance space is examined not only for its functional characters but also for its symbolic power in structuring or changing the historical and cultural identity of the entire museum’s building. Both in new projects and in restoration of ancient museum buildings, in fact, contemporary architects seems to be increasingly attracted by this design aspect.

  12. Does China¡¯s National College Entrance Exam Effectively Evaluate Applicants?

    OpenAIRE

    Wei Hu; Feng Li; Li Gan

    2014-01-01

    Based on micro-level student data from one Chinese academic institution, we study the validity of the national college entrance exam from the perspective of student performance in college and employment prospects after graduation. We find that the current college entrance exam could reflect the students¡¯ learning ability to a certain degree, providing a relatively valid evaluation. Demonstration of well-rounded development ability should be an important factor in the evaluation system. Based...

  13. Method of estimating patient skin dose from dose displayed on medical X-ray equipment with flat panel detector

    International Nuclear Information System (INIS)

    Fukuda, Atsushi; Koshida, Kichiro; Togashi, Atsuhiko; Matsubara, Kousuke

    2004-01-01

    The International Electrotechnical Commission (IEC) has stipulated that medical X-ray equipment for interventional procedures must display radiation doses such as air kerma in free air at the interventional reference point and dose area product to establish radiation safety for patients (IEC 60601-2-43). However, it is necessary to estimate entrance skin dose for the patient from air kerma for an accurate risk assessment of radiation skin injury. To estimate entrance skin dose from displayed air kerma in free air at the interventional reference point, it is necessary to consider effective energy, the ratio of the mass-energy absorption coefficient for skin and air, and the backscatter factor. In addition, since automatic exposure control is installed in medical X-ray equipment with flat panel detectors, it is necessary to know the characteristics of control to estimate exposure dose. In order to calculate entrance skin dose under various conditions, we investigated clinical parameters such as tube voltage, tube current, pulse width, additional filter, and focal spot size, as functions of patient body size. We also measured the effective energy of X-ray exposure for the patient as a function of clinical parameter settings. We found that the conversion factor from air kerma in free air to entrance skin dose is about 1.4 for protection. (author)

  14. Calculation of entrance exposed area from recorded images in cardiac diagnostic and interventional procedures

    International Nuclear Information System (INIS)

    Bibbo, G.; Balman, D.

    2000-01-01

    With increasing number of interventional radiological procedures performed on patients of all ages, it is important to determine the skin entrance dose of patients to limit the side effects of radiation. In most cases the skin dose is measured using thermoluminescent detectors (TLD). However, these detectors need to be placed in the radiation field on the skin of the patient, which may interfere with the procedure. Also, not all radiological practices are equipped with TLD readers which are expensive or have staff with the appropriate knowledge and expertise to be able to make use of TLD. The alternative to TLD is to use the dose area product (DAP) measured with a diamentor fitted to the angiography x-ray equipment. The difficulties in using DAP to calculate skin dose is that the irradiated area of the skin is not known. The area could change in size and location during the procedure as the radiologist/medical specialist varies the collimation and region of interest. For angiography equipment the distance between the anode and image intensifier is variable, as is the height of the examination table. The only point of reference is the isocentre. With recorded images it is possible to determine the irradiated area of the patient at the isocentre plane using the stenosis algorithm. The recorded image is calibrated such that it corresponds to the physical size in the plane of the isocentre. For non-recorded images, it may be necessary to assume that collimation has not changed and that the irradiated area is the same as that shown on the recorded images. The Women's and Children's Hospital has a Toshiba DFP2000 Biplane Digital Imaging system used for all cardiac and general angiography and interventional procedures. With this system the exposure factors (kVp, mA, field sizes) are recorded with the images. The source to image distance (SID), magnification factor (calibration factor of the recorded images) and angle of rotation are displayed on the Display Panel of the

  15. Engineering geologic conditions at the sinkhole entrance to Logan Cave, Benton County, Arkansas

    Science.gov (United States)

    Schulz, William H.; McKenna, Jonathan P.

    2004-01-01

    Logan Cave, located in Benton County, Arkansas, is inhabited by several endangered and threatened species. The cave and surrounding area was designated a National Wildlife Refuge under the control of the U.S. Fish and Wildlife Service (USFWS) in 1989. Cave researchers access the cave through a steep-sided sinkhole entrance, which also is one of the two access points used by endangered bats. There is evidence of instability of one of the entrance slopes that has raised concerns that the entrance could close if slope failure was to occur. At the request of USFWS, we performed an engineering geologic investigation of the sinkhole to evaluate stability of this slope, which is comprised of soil, and other mechanisms of sediment transport into the cave entrance. The investigation included engineering geologic mapping, sampling and laboratory testing of subsurface geologic materials, and slope-stability analysis. We found that the sinkhole slope that extends into the entrance of the cave is comprised of sandy and gravelly soil to the depths explored (6.4 meters). This soil likely was deposited as alluvium within a previous, larger sinkhole. Based on properties of the alluvium, geometry of the slope, and results of finite-element slope-stability analyses, we conclude that the slope is marginally stable. Future failures of the slope probably would be relatively thin and small, thus several would be required to completely close the cave entrance. However, sediment is accumulating within the cave entrance due to foot traffic of those accessing the cave, surface-water erosion and transport, and shallow slope failures from the other sinkhole slopes. We conclude that the entrance will be closed by sediment in the future, similar to another entrance that we identified that completely closed in the past. Several measures could be taken to reduce the potential for closure of the cave entrance, including periodic sediment removal, installation of materials that reduce erosion by

  16. A comparison of the suitability of patient dosimetry methods for establishing diagnostic dose reference levels and optimisation strategies

    International Nuclear Information System (INIS)

    Gfirtner, Hans; Moores, B. Michael; Stieve, Friedrich E.

    2008-01-01

    For 50 adult patients referred for chest radiography, air kerma at the diaphragm KD, dose area product and entrance skin dose were measured. The air kerma at the diaphragm and the dose area product were determined using Diamentor M4KDK(PTW) which allows measuring air kerma and dose area product simultaneously. For the measurement of entrance skin dose TLDs are used. A 50% variation in dose, incident dose as well as entrance skin dose, was registered for the same patient thickness. The recommendation of ICRP to perform the measurements for DRLs at 'representative patients' and that of the CEC to use 'standard-sized patients' seem to make little sense in the case of chest radiography. It could be demonstrated, that the dose area product is the least appropriate dose quantity for patient measurements and to define dose reference levels. For some radiological examinations like chest, pelvis and lumbar spine the dose area product is even sex dependent. Incident dose and entrance surface dose are of equal quality for patient dose measurements in diagnostic radiography. (author)

  17. Vitamin D production depends on ultraviolet-B dose but not on dose rate: a randomized controlled trial

    DEFF Research Database (Denmark)

    Bogh, Morten K B; Schmedes, Anne V; Philipsen, Peter A

    2011-01-01

    Ultraviolet-B (UV-B) radiation increases serum vitamin D level expressed as 25-hydroxyvitamin D(3) (25(OH)D), but the dose-response relationship and the importance of dose rate is unclear. Of 172 fair-skinned persons screened for 25(OH)D, 55 with insufficient baseline 25(OH)D=50 nm (mean 31.2 nm...... exposed. Skin pigmentation and 25(OH)D were measured before and after the irradiations. The increase in 25(OH)D after UV-B exposure (adjusted for baseline 25(OH)D) was positively correlated with the UV-B dose (P=0.001; R(2) =0.176) but not to dose rate (1-20 min). 25(OH)D increased in response to four UV......-B treatments of 3 SED with 24.8 nm on average and 14.2 nm after four UV-B treatments of just 0.375 SED. In conclusion, the increase in 25(OH)D after UV-B exposure depends on the dose but not on the dose rate (1-20 min). Further, a significant increase in 25(OH)D was achieved with a very low UV-B dose....

  18. Determination of effective dose in pediatric radiodiagnostic in Medellin-Colombia

    International Nuclear Information System (INIS)

    Garzon, William J.; Aramburo, Javier M.; Jimenez, Angelmiro A.; Ortiz, Anselmo P.

    2013-01-01

    In order to know the effective dose in pediatric X-ray exams of chest, entrance surface dose measurements were performed for ages 1,5 and 10 years in the largest pediatric hospital in the city of Medellin, Colombia. The effective dose was obtained from applying the conversion coefficients to measures of the entrance surface dose (ESD) in 306 radiographic studies in AP and LAT I projections. The results were validated with PCXMC 2.0 computer program and other work reported in the literature. (author)

  19. Evaluation of patient dose saving in grid-less x-ray mammography acquisition compared with full field digital mammography (FFDMG) acquisition

    DEFF Research Database (Denmark)

    Abdi, Ahmed Jibril; Mussmann, Bo Redder

    2017-01-01

    to investigate the dose saving in grid-less acquisition compared with conventional full-field digital mammography (FFDMG) acquisitions. A Piranha 657 was used to measure the entrance exposure. The entrance exposure was directly measured on different PMMA thicknesses of 20-70mm in steps of 10mm. The PMMA block...

  20. The Effect of the Pore Entrance on Particle Motion in Slit Pores: Implications for Ultrathin Membranes.

    Science.gov (United States)

    Delavari, Armin; Baltus, Ruth

    2017-08-10

    Membrane rejection models generally neglect the effect of the pore entrance on intrapore particle transport. However, entrance effects are expected to be particularly important with ultrathin membranes, where membrane thickness is typically comparable to pore size. In this work, a 2D model was developed to simulate particle motion for spherical particles moving at small Re and infinite Pe from the reservoir outside the pore into a slit pore. Using a finite element method, particles were tracked as they accelerated across the pore entrance until they reached a steady velocity in the pore. The axial position in the pore where particle motion becomes steady is defined as the particle entrance length (PEL). PELs were found to be comparable to the fluid entrance length, larger than the pore size and larger than the thickness typical of many ultrathin membranes. Results also show that, in the absence of particle diffusion, hydrodynamic particle-membrane interactions at the pore mouth result in particle "funneling" in the pore, yielding cross-pore particle concentration profiles focused at the pore centerline. The implications of these phenomena on rejection from ultrathin membranes are examined.

  1. Public Service Entrance Examinations for Executive Secretary Position in Federal Institutions of Higher Education

    Directory of Open Access Journals (Sweden)

    Luciana Nunes de Oliveira

    2016-12-01

    Full Text Available The professional with a bachelor in Secretarial Science is increasingly placed on the labor market, both in the private and the public sector. However, recent public service entrance examination, on several occasions, offer positions for executive secretary – in which, neither the undergraduate degree in Secretarial Science nor the professional registry is mandatory, allowing undergraduates in different areas enter the public sector as executive secretaries. On the above, this article aims at identifying and introduce the public service entrance examinations for executive secretary, specifically in the Federal Institutions of Higher Education (IFES, from 2009 to 2015. It was identified 110 public service entrance examination rules which provided 531 positions. Of these, only 308 positions (from 57 public service entrance examination rules were exclusively intended for applicants professionally qualified according to the Law No 7.377 of September 30th, 1985. It was noted that some IFES did not demand, in their public service entrance examination rules, the professional qualification required by the Circular Letter No 015/2005 from MEC, causing a loss to the professionals with the professional qualification.

  2. SedInConnect: a stand-alone, free and open source tool for the assessment of sediment connectivity

    Science.gov (United States)

    Crema, Stefano; Cavalli, Marco

    2018-02-01

    There is a growing call, within the scientific community, for solid theoretic frameworks and usable indices/models to assess sediment connectivity. Connectivity plays a significant role in characterizing structural properties of the landscape and, when considered in combination with forcing processes (e.g., rainfall-runoff modelling), can represent a valuable analysis for an improved landscape management. In this work, the authors present the development and application of SedInConnect: a free, open source and stand-alone application for the computation of the Index of Connectivity (IC), as expressed in Cavalli et al. (2013) with the addition of specific innovative features. The tool is intended to have a wide variety of users, both from the scientific community and from the authorities involved in the environmental planning. Thanks to its open source nature, the tool can be adapted and/or integrated according to the users' requirements. Furthermore, presenting an easy-to-use interface and being a stand-alone application, the tool can help management experts in the quantitative assessment of sediment connectivity in the context of hazard and risk assessment. An application to a sample dataset and an overview on up-to-date applications of the approach and of the tool shows the development potential of such analyses. The modelled connectivity, in fact, appears suitable not only to characterize sediment dynamics at the catchment scale but also to integrate prediction models and as a tool for helping geomorphological interpretation.

  3. FHSA-SED: Two-Locus Model Detection for Genome-Wide Association Study with Harmony Search Algorithm.

    Directory of Open Access Journals (Sweden)

    Shouheng Tuo

    Full Text Available Two-locus model is a typical significant disease model to be identified in genome-wide association study (GWAS. Due to intensive computational burden and diversity of disease models, existing methods have drawbacks on low detection power, high computation cost, and preference for some types of disease models.In this study, two scoring functions (Bayesian network based K2-score and Gini-score are used for characterizing two SNP locus as a candidate model, the two criteria are adopted simultaneously for improving identification power and tackling the preference problem to disease models. Harmony search algorithm (HSA is improved for quickly finding the most likely candidate models among all two-locus models, in which a local search algorithm with two-dimensional tabu table is presented to avoid repeatedly evaluating some disease models that have strong marginal effect. Finally G-test statistic is used to further test the candidate models.We investigate our method named FHSA-SED on 82 simulated datasets and a real AMD dataset, and compare it with two typical methods (MACOED and CSE which have been developed recently based on swarm intelligent search algorithm. The results of simulation experiments indicate that our method outperforms the two compared algorithms in terms of detection power, computation time, evaluation times, sensitivity (TPR, specificity (SPC, positive predictive value (PPV and accuracy (ACC. Our method has identified two SNPs (rs3775652 and rs10511467 that may be also associated with disease in AMD dataset.

  4. Method to stimulate dose gradient in liquid media

    International Nuclear Information System (INIS)

    Scarlat, F.

    1993-01-01

    The depth absorbed dose from electrons with energy higher than 10 MeV shows a distribution with a big-percentage absorbed dose at the entrance surface and a small dose gradient. This is due to the big distance between the virtual focus and irradiated liquid medium. In order to stimulate dose gradient and decrease the surface dose, this paper presents a method for obtaining the second focus by means of a magnetostatic planar wiggler. Preliminary calculations indicated that the absorbed dose rate increases two-three times at the reference plane in the irradiated liquid medium. (Author)

  5. A novel beam focus control at the entrance to the ANU 14UD accelerator

    International Nuclear Information System (INIS)

    De Cesare, M.; Weisser, D. C.; Fifield, L. K.; Tunningley, T. B.; Lobanov, N. R.

    2013-01-01

    Tandem electrostatic accelerators often require the flexibility to operate at variety of terminal voltages to cater for various user needs. However beam transmission will only be optimal for a limited range of terminal voltages. This paper describes a focussing system that greatly expands the range of terminal voltages for optimal transmission. This is achieved by controlling the gradient of the entrance of the low-energy tube providing an additional controllable focusing element. Up to 150 kV is applied to the fifth electrode of the first unit of the accelerator tube giving control of the tube entrance lens strength. Beam tests to confirm the efficacy of the lens have been performed. These tests demonstrate that the entrance lens control eliminates the need to short out sections of the tube for low terminal voltage operation. (authors)

  6. Investigation of entrance length in circular and noncircular conduits by computational fluid dynamics simulation

    Directory of Open Access Journals (Sweden)

    Pimpun Tongpun

    2014-08-01

    Full Text Available This study estimated entrance length of circular and noncircular conduits, including circle, triangle, square and hexagon cross-sectional conduit, by using computational fluid dynamics (CFD. For simulation condition, the length of noncircular conduit was 10 m and the hydraulic diameter was 0.2 m. The laminar flow with Reynolds number of 500 and turbulent flow with Reynolds number of 50,000 were applied to investigate water flow in conduits. The governing equations were solved iteratively by using ANSYS FLUENT 14.0. For turbulent flow simulation, standard k-epsilon and RNG k-epsilon model were employed to simulate turbulence. The preliminary results were validated by comparison with theoretical data. At first, grid independency was evaluated to optimize the model. Norm* was employed to investigate the entrance length, which is related to velocity. The simulated results revealed that the entrance length for laminar flow was longer than turbulent flow.

  7. Radiation doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Theodorakou, C.; Butler, P.; Horrocks, J.A.

    2001-01-01

    Patient radiation doses during interventional radiology (IR) procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the radiation doses received by patients undergoing cerebral embolization. Measurements were conducted using thermoluminescent dosimeters. Radiotherapy verification films were used in order to visualise the radiation field. For each procedure the fluoroscopic and digital dose-area product, the fluoroscopic time, the total number of acquired images and entrance-skin dose calculated by the angiographic unit were recorded. In this paper, the skin, eye and thyroid glands doses on a sample of patients are presented. From a preliminary study of 13 patients having undergone cerebral embolization, it was deduced that six of them have received a dose above 1 Gy. Detailed dose data from patients undergoing IR procedures will be collected in the future with the aim of developing a model to allow estimation of the dose prior to the procedure as well as to look at techniques of dose reduction. (author)

  8. Safety Evaluation of the Lighting at the Entrance of a Very Long Road Tunnel: A Case Study in Ilam

    Directory of Open Access Journals (Sweden)

    Ahmad Mehri

    2017-06-01

    Conclusion: A comparison between the results of the safe levels of lighting at the entrance of the tunnel and the De Boer scale showed that the phenomenon of black holes is created at the tunnel entrance. This may lead to a misadaptation of the drivers’ eyes to the change in luminance level at the entrance of the tunnel, thereby increasing the risk of road accidents in this zone.

  9. Baja Andesia: sed y poéticas tramontinas. Un desvío etnográfico a mano alzada

    Directory of Open Access Journals (Sweden)

    Pedro Araya

    2007-07-01

    Full Text Available Si yo fuese dromedario no tendría sed. ¿Qué hora es ?Vicente Huidobro1.El antropólogo-poeta-ponencista despierta luego de un sueño intranquilo. Tiene sed. Algo recuerda. Un escozor, dice, un poco antes, en la misma, como de ron, como de vino y el fumadero de las caras ; como si, apenas, algo de lo exagerado de una opinión, entre una cosa y la otra, hubiera olvidado. Sabe que debe hablar aquella misma mañana. Sabe. La pata de los caballos, piensa. La tribu estará reunida. No la suya. No se sus...

  10. Quality and clinical supply considerations of Paediatric Investigation Plans for IV preparations-A case study with the FP7 CloSed project.

    Science.gov (United States)

    Hanning, Sara M; Orlu Gul, Mine; Winslade, Jackie; Baarslag, Manuel A; Neubert, Antje; Tuleu, Catherine

    2016-09-25

    A Paediatric Investigation Plan (PIP) is a development plan that aims to ensure that sufficient data are obtained through studies in paediatrics to support the generation of marketing authorisation of medicines for children. This paper highlights some practical considerations and challenges with respect to PIP submissions and paediatric clinical trials during the pharmaceutical development phase, using the FP7-funded Clonidine for Sedation of Paediatric Patients in the Intensive Care Unit (CloSed) project as a case study. Examples discussed include challenges and considerations regarding formulation development, blinding and randomisation, product labelling and shipment and clinical trial requirements versus requirements for marketing authorisation. A significant quantity of information is required for PIP submissions and it is hoped that future applicants may benefit from an insight into some critical considerations and challenges faced in the CloSed project. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Effects of Magnetic Particles Entrance Arrange-ments on Mixing Efficiency of a Magnetic Bead Micromixer

    Institute of Scientific and Technical Information of China (English)

    Reza Kamali∗; Seyed Alireza Shekoohi; Alireza Binesh

    2014-01-01

    In this study, a computer code is developed to numerically investigate a magnetic bead micromixer under different conditions. The micromixer consists of a microchannel and numerous micro magnetic particles which enter the micromixer by fluid flows and are actuated by an alternating magnetic field normal to the main flow. An important feature of micromixer which is not considered before by researchers is the particle entrance arrangement into the micromixer. This parameter could effectively affect the micromixer efficiency. There are two general micro magnetic particle entrance arrangements in magnetic bead micromixers: determined position entrance and random position entrance. In the case of determined position entrances, micro magnetic particles enter the micromixer at specific positions of entrance cross section. However, in a random position entrance, particles enter the microchannel with no order. In this study mixing efficiencies of identical magnetic bead micromixers which only differ in particle entrance arrangement are numerically investigated and compared. The results reported in this paper illustrate that the prepared computer code can be one of the most powerful and beneficial tools for the magnetic bead micromixer performance analysis. In addition, the results show that some features of the magnetic bead micromixer are strongly affected by the entrance arrangement of the particles.

  12. Analysis of the Existing Parameters of the Ports Entrances in the World in Terms of Their Design

    Directory of Open Access Journals (Sweden)

    Dominika Kosc‐Pawlicka

    2017-09-01

    Full Text Available This article aims to analyse the statistical parameters of waterways forming the entrance to the port and the construction of a model for determining the optimum parameters of the entrance to the port. It has been analyzed parameters of the entrances to the 100 selected global ports, based on the analysis it was examined the interdependence between certain parameters and the impact they have on the maximum size of the ship which can enter to the port. This analysis allowed to develop a model, which can possible to be applied to the entrance of initial port design.

  13. Patient Doses and Risk Evaluation in Bone Mineral Densitometry

    International Nuclear Information System (INIS)

    Angelucci, M.; Borio, R.; Chiocchini, S.; Degli Esposti, P.; Dipilato, A.C.; Policani, G.

    1999-01-01

    The aim of this work was to evaluate the equipment dose to the organs and tissues and the effective dose of patients undergoing the most frequent examinations carried out in bone mineral densitometry (BMD): lumbar spine and femur. Experimental measurements of absorbed doses on a Rando phantom, allow comparison of the performances of three different photon emitter facilities. The comparison of the entrance and exit doses measured on a Rando phantom and on 50 female non-obese patients show that entrance doses on Rando can be used as 'diagnostic reference levels' for patients. A quantitative estimate of the stochastic risk due to BMD procedures was made: the results obtained show that the stochastic risk is very low and that the BMD is, at present, the most confirmed procedure for osteoporosis diagnosis and management. (author)

  14. Evaluation of pediatrics entrance surface air kerma during chest X-ray examinations in some Khartoum hospitals

    International Nuclear Information System (INIS)

    Mohamed, Hassan Ishag Yahya

    2015-10-01

    The aim of this study was to determine the amount of entrance surface air kerma dose in air that can reflect the amount of the risk that the children, are subjected to. The parameters that are involved in this project are x-ray tube current (mA), exposure time (sec.), and focal skin distance (FSD) in cm. ESAK is calculated using the equation: ESAK=(Output (mGy/mAs) x (100/FSD) 2 X mAs) for different examination of different patients. 65 cases were involved in this study, the results show that the ESAK mean value (0.18±0.07) mGy, (0.06±0.07) mGy, (0.045±0.017) mGy and (0.049±0.013) mGy at the hospitals (IBNIOF Omdurman, police, clinic doctor) respectively. IBNIOF presented the highest ESAK (0.18±0.07) mGy, while it was lowest in police (0.045±0.017) mGy. The estimated ESAK value were within the established international reference dose values and also the values obtained in pervious studies however, variations were observed in ESAK values among hospitals under study which could be due to the differences in exposure parameters used. Also tube output has some effect on obtained ESAK. (author)

  15. Why Do Some Estuaries Close: A Model of Estuary Entrance Morphodynamics.

    Science.gov (United States)

    McSweeney, S. L.; Kennedy, D. M.; Rutherfurd, I.

    2014-12-01

    Intermittently Closed/Open Coastal Lakes/Lagoons (ICOLLs) are a form of wave-dominated, microtidal estuary that experience periodic closure in times of low river flow. ICOLL entrance morphodynamics are complex due to the interaction between wave, tidal and fluvial processes. Managers invest substantial funds to artificially open ICOLLs as they flood surrounding property and infrastructure, and have poor water quality. Existing studies examine broad scale processes but do not identify the main drivers of entrance condition. In this research, the changes in entrance geomorphology were surveyed before and after artificial entrance openings in three ICOLLs in Victoria, Australia. Changes in morphology were related to continuous measures of sediment volume, water level, tide and wave energy. A six-stage quantitative phase model of entrance geomorphology and hydrodynamics is presented to illustrate the spatio-temporal variability in ICOLL entrance morphodynamics. Phases include: breakout; channel expansion with rapid outflow; open with tidal exchange; initial berm rebuilding with tidal attenuation; partial berm recovery with rising water levels; closed with perched water levels. Entrance breakout initiates incision of a pilot channel to the ocean, whereby basin water levels then decline and channel expansion as the headcut migrates landwards. Peak outflow velocities of 5 m/s-3 were recorded and channel dimensions increased over 6 hrs to 3.5 m deep and 140 m wide. When tidal, a clear semi-diurnal signal is superimposed upon an otherwise stable water level. Deep-water wave energy was transferred 1.8 km upstream of the rivermouth with bores present in the basin. Berm rebuilding occurred by littoral drift and cross-shore transport once outflow ceased and microscale bedform features, particularly antidunes, contributed to sediment progradation. Phase duration is dependant on how high the estuary was perched above mean sea level, tidal prism extent, and onshore sediment supply

  16. Reference Dose Rates for Fluoroscopy Guided Interventions

    International Nuclear Information System (INIS)

    Geleijns, J.; Broerse, J.J.; Hummel, W.A.; Schalij, M.J.; Schultze Kool, L.J.; Teeuwisse, W.; Zoetelief, J.

    1998-01-01

    The wide diversity of fluoroscopy guided interventions which have become available in recent years has improved patient care. They are being performed in increasing numbers, particularly at departments of cardiology and radiology. Some procedures are very complex and require extended fluoroscopy times, i.e. longer than 30 min, and radiation exposure of patient and medical staff is in some cases rather high. The occurrence of radiation-induced skin injuries on patients has shown that radiation protection for fluoroscopy guided interventions should not only be focused on stochastic effects, i.e. tumour induction and hereditary risks, but also on potential deterministic effects. Reference dose levels are introduced by the Council of the European Communities as an instrument to achieve optimisation of radiation protection in radiology. Reference levels in conventional diagnostic radiology are usually expressed as entrance skin dose or dose-area product. It is not possible to define a standard procedure for complex interventions due to the large inter-patient variations with regard to the complexity of specific interventional procedures. Consequently, it is not realistic to establish a reference skin dose or dose-area product for complex fluoroscopy guided interventions. As an alternative, reference values for fluoroscopy guided interventions can be expressed as the entrance dose rates on a homogeneous phantom and on the image intensifier. A protocol has been developed and applied during a nationwide survey of fluoroscopic dose rate during catheter ablations. From this survey reference entrance dose rates of respectively 30 mGy.min -1 on a polymethylmethacrylate (PMMA) phantom with a thickness of 21 cm, and of 0.8 μGy.s -1 on the image intensifier have been derived. (author)

  17. Estimation of dose to patients undergoing computed radiography x-ray examinations in some Khartoum hospitals

    International Nuclear Information System (INIS)

    Badri, Fatima Abulgasiem Abdulrhman

    2015-12-01

    This study was designed to evaluate the entrance surface air kerma to the patient during x-ray examination to (chest PA, lumbar spine AP and Lat, pelvis AP) by using computed radiography (CR) in different three hospitals in Khartoum. Three x-ray machines were covered. A total of 135 patients were evaluated. The entrance surface air kerma was calculated for each patient from the exposure parameters using cal dose software version 3.5. The obtained results showed that, the entrance surface air kerma range founded to be (0.28-1.59) for chest PA, (1.98-2.62) for lumbar spine and (0.438-2.47) for pelvis AP. The higher entrance surface air kerma for all projections were observed in Center 1, except for pelvis it is higher in center 2. And the lower entrance surface air kerma were observed in center 3. This study recommends that CR operator must to be used to achieve optimize the patient dose by use the best strategies available for reducing radiation dose, computed radiography must be used with high level of training for medical staff to reduce the dose, each radiology department should implement a patient dose measurement quality assurance programme, doses to the patients should be regularly monitored and the proposed national DRLs should be taken as guidance for optimization.(Author)

  18. SedCT: MATLAB™ tools for standardized and quantitative processing of sediment core computed tomography (CT) data collected using a medical CT scanner

    Science.gov (United States)

    Reilly, B. T.; Stoner, J. S.; Wiest, J.

    2017-08-01

    Computed tomography (CT) of sediment cores allows for high-resolution images, three-dimensional volumes, and down core profiles. These quantitative data are generated through the attenuation of X-rays, which are sensitive to sediment density and atomic number, and are stored in pixels as relative gray scale values or Hounsfield units (HU). We present a suite of MATLAB™ tools specifically designed for routine sediment core analysis as a means to standardize and better quantify the products of CT data collected on medical CT scanners. SedCT uses a graphical interface to process Digital Imaging and Communications in Medicine (DICOM) files, stitch overlapping scanned intervals, and create down core HU profiles in a manner robust to normal coring imperfections. Utilizing a random sampling technique, SedCT reduces data size and allows for quick processing on typical laptop computers. SedCTimage uses a graphical interface to create quality tiff files of CT slices that are scaled to a user-defined HU range, preserving the quantitative nature of CT images and easily allowing for comparison between sediment cores with different HU means and variance. These tools are presented along with examples from lacustrine and marine sediment cores to highlight the robustness and quantitative nature of this method.

  19. From "E-flows" to "Sed-flows": Managing the Problem of Sediment in High Altitude Hydropower Systems

    Science.gov (United States)

    Gabbud, C.; Lane, S. N.

    2017-12-01

    The connections between stream hydraulics, geomorphology and ecosystems in mountain rivers have been substantially perturbed by humans, for example through flow regulation related to hydropower activities. It is well known that the ecosystem impacts downstream of hydropower dams may be managed by a properly designed compensation release or environmental flows ("e-flows"), and such flows may also include sediment considerations (e.g. to break up bed armor). However, there has been much less attention given to the ecosystem impacts of water intakes (where water is extracted and transferred for storage and/or power production), even though in many mountain systems such intakes may be prevalent. Flow intakes tend to be smaller than dams and because they fill quickly in the presence of sediment delivery, they often need to be flushed, many times within a day in Alpine glaciated catchments with high sediment yields. The associated short duration "flood" flow is characterised by very high sediment concentrations, which may drastically modify downstream habitat, both during the floods but also due to subsequent accumulation of "legacy" sediment. The impacts on flora and fauna of these systems have not been well studied. In addition, there are no guidelines established that might allow the design of "e-flows" that also treat this sediment problem, something we call "sed-flows". Through an Alpine field example, we quantify the hydrological, geomorphological, and ecosystem impacts of Alpine water transfer systems. The high sediment concentrations of these flushing flows lead to very high rates of channel disturbance downstream, superimposed upon long-term and progressive bed sediment accumulation. Monthly macroinvertebrate surveys over almost a two-year period showed that reductions in the flushing rate reduced rates of disturbance substantially, and led to rapid macroinvertebrate recovery, even in the seasons (autumn and winter) when biological activity should be reduced

  20. Tracing catchment fine sediment sources using the new SIFT (SedIment Fingerprinting Tool) open source software.

    Science.gov (United States)

    Pulley, S; Collins, A L

    2018-09-01

    The mitigation of diffuse sediment pollution requires reliable provenance information so that measures can be targeted. Sediment source fingerprinting represents one approach for supporting these needs, but recent methodological developments have resulted in an increasing complexity of data processing methods rendering the approach less accessible to non-specialists. A comprehensive new software programme (SIFT; SedIment Fingerprinting Tool) has therefore been developed which guides the user through critical data analysis decisions and automates all calculations. Multiple source group configurations and composite fingerprints are identified and tested using multiple methods of uncertainty analysis. This aims to explore the sediment provenance information provided by the tracers more comprehensively than a single model, and allows for model configurations with high uncertainties to be rejected. This paper provides an overview of its application to an agricultural catchment in the UK to determine if the approach used can provide a reduction in uncertainty and increase in precision. Five source group classifications were used; three formed using a k-means cluster analysis containing 2, 3 and 4 clusters, and two a-priori groups based upon catchment geology. Three different composite fingerprints were used for each classification and bi-plots, range tests, tracer variability ratios and virtual mixtures tested the reliability of each model configuration. Some model configurations performed poorly when apportioning the composition of virtual mixtures, and different model configurations could produce different sediment provenance results despite using composite fingerprints able to discriminate robustly between the source groups. Despite this uncertainty, dominant sediment sources were identified, and those in close proximity to each sediment sampling location were found to be of greatest importance. This new software, by integrating recent methodological developments in

  1. Radiation absorbed doses in cephalography

    International Nuclear Information System (INIS)

    Eliasson, S.; Julin, P.; Richter, S.; Stenstroem, B.

    1984-01-01

    Radiation absorbed doses to different organs in the head and neck region in lateral (LAT) and postero-anterior (PA) cephalography were investigated. The doses were measured by thermoluminescence dosimeters (TLD) on a tissue equivalent phantom head. Lanthanide screens in speed group 4 were used at 90 and 85 k Vp. A near-focus aluminium dodger was used and the radiation beam was collimated strictly to the face. The maximum entrance dose from LAT was 0.25 mGy and 0.42 mGy from a PA exposure. The doses to the salivary glands ranged between 0.2 and 0.02 mGy at LAT and between 0.15 and 0.04 mGy at PA exposures. The average thyroid gland dose without any shielding was 0.11 mGy (LAT) and 0.06 mGy (PA). When a dodger was used the dose was reduced to 0.07 mGy (LAT). If the thyroid gland was sheilded off, the dose was further reduced to 0.01 mGy and if the thyroid region was collimated out of the primary radiation field the dose was reduced to only 0.005 mGy. (authors)

  2. Assessment of pediatrics radiation dose from routine x-ray ...

    African Journals Online (AJOL)

    Background: Given the fact that children are more sensitive to ionizing radiation than adults,with an increased risk of developing radiation-induced cancer,special care should be taken when they undergo X-ray examinations. The main aim of the current study was to determine Entrance Surface Dose (ESD) to pediatric ...

  3. An Animal Model of Active (Act) Versus Sedentary (Sed) Lifestyle and Susceptibility to Air Pollution: Response to Ozone (O3) in Female Sprague-Dawley Rats Allowed to Train Chronically On Running Wheels

    Science.gov (United States)

    Epidemiological data suggest that a sedentary lifestyle may contribute to increased suseptibility to environmental pollutants. Furthermore, the association between a sedentary pattern and development of obesity may exacerbate susceptibility. To study the effects of ACT vs. SED l...

  4. Sleep Patterns and Academic Performance during Preparation for College Entrance Exam in Chinese Adolescents

    Science.gov (United States)

    Wang, Guanghai; Ren, Fen; Liu, Zhijun; Xu, Guangxing; Jiang, Fan; Skora, Elizabeth; Lewin, Daniel S.

    2016-01-01

    Background: Deficient sleep is linked to detrimental outcomes in health and school performance for adolescents. This study characterized sleep patterns in Chinese adolescents preparing for the College Entrance Exam (CEE) and evaluated the association between sleep patterns, self-rated academic performance, and the CEE scores. Methods: A sample of…

  5. Learning beyond graduation: exploring newly qualified specialists' entrance into daily practice from a learning perspective.

    Science.gov (United States)

    Cuyvers, Katrien; Donche, Vincent; Van den Bossche, Piet

    2016-05-01

    The entrance of newly qualified medical specialists into daily practice is considered to be a stressful period in which curriculum support is absent. Although engaging in both personal and professional learning and development activities is recognized fundamental for lifelong professional competence, research on medical professionals' entrance into practice is scarce. This research aims to contribute to the framework of medical professionals' informal learning and outlines the results of an exploratory study on the nature of learning in daily practice beyond postgraduate training. Eleven newly qualified physicians from different specialized backgrounds participated in a phenomenographic study, using a critical incident method and a grounded theory approach. Results demonstrated that learning in the workplace is, to a large extent, informal and associated with a variety of learning experiences. Analysis shows that experiences related to diagnostics and treatments are important sources for learning. Furthermore, incidents related to communication, changing roles, policy and organization offer learning opportunities, and therefore categorized as learning experiences. A broad range of learning activities are identified in dealing with these learning experiences. More specifically, actively engaging in actions and interactions, especially with colleagues of the same specialty, are the most mentioned. Observing others, consulting written sources, and recognizing uncertainties, are also referred to as learning activities. In the study, interaction, solely or combined with other learning activities, are deemed as very important by specialists in the initial entrance into practice. These insights can be used to develop workplace structures to support the entrance into practice following postgraduate training.

  6. Entrance Qualifications Affect the Performance of Nutrition Students at University: A Pilot Study

    Science.gov (United States)

    Owusu-Apenten, Richard; Xu, Wen Li

    2012-01-01

    This study assessed the effect of admissions qualifications on the subsequent academic performances of BSc nutrition students at a UK university. Entrance qualifications for three groups (Grp01, Grp02, Grp03) reading for a BSc(Hons) degree in, Dietetics, Food & Nutrition or Human Nutrition (n = 105) were determined from their UCAS…

  7. Mean temperature profile at the entrance of a thermoacoustic stacked screen heat exchanger

    NARCIS (Netherlands)

    Bühler, Simon; wilcox, D; Oosterhuis, Joris; van der Meer, Theodorus H.

    2015-01-01

    In thermoacoustic devises, the thermoacoustic e ect occurs in the regenerator placed between two heat exchangers. The entrance e ects of such heat exchanger are investigated with two computational uid dynamics (CFD) test cases. The rst CFD test case models an ideal heat exchanger adjacent to an open

  8. Toward Implementing Computer-Assisted Foreign Language Assessment in the Official Spanish University Entrance Examination

    Science.gov (United States)

    Sanz, Ana Gimeno; Pavón, Ana Sevilla

    2015-01-01

    In 2008 the Spanish Government announced the inclusion of an oral section in the foreign language exam of the National University Entrance Examination during the year 2012 (Royal Decree 1892/2008, of 14 November 2008, Ministerio de Educación, Gobierno de España, 2008). Still awaiting the implementation of these changes, and in an attempt to offer…

  9. 78 FR 64523 - Agency Information Collection Activities: Vessel Entrance or Clearance Statement

    Science.gov (United States)

    2013-10-29

    ... respondents or record keepers from the collection of information (a total capital/startup costs and operations... vessel data at time of formal entrance and clearance in U.S. ports. The form allows the master to attest... Responses per Respondent: 22. Estimated Total Annual Responses: 264,000. Estimated Time per Response: 30...

  10. Investigating the Association between Turkish Freshman's Multiple Intelligence Profiles and University Entrance Exam Performance

    Science.gov (United States)

    Atas, Sait; Erisen, Yavuz

    2016-01-01

    Even though curriculum designers in Turkey considered Gardner's multiple intelligence theory as one of the most important theories during the curricula reform in 2005, the university entrance examination system is still on the basis of the two intelligence areas only, mathematical-logical and linguistics intelligence. The aim of this study was to…

  11. WIRED NEXTFest invites Virginia Tech architecture students, professor to create archway entrance to the festival

    OpenAIRE

    Chadwick, Heather Riley

    2008-01-01

    An undergraduate student team from Virginia Tech's School of Architecture + Design in the College of Architecture and Urban Studies led by Terry Surjan, associate professor of architecture, is traveling to Chicago this month to erect and display an archway/pavilion entrance to WIRED magazine's highly acclaimed NEXTFest at Millennium Park.

  12. Protected area entrance fees in Tanzania: The search for competitiveness and value for money

    Directory of Open Access Journals (Sweden)

    Anna Spenceley

    2017-03-01

    Full Text Available User fees charged by Tanzania’s Game Reserves (GR and Wildlife Management Areas (WMAs have not changed since 2008. Although previous research has been done on visitors’ willingness-to-pay to enter national parks in Tanzania, none has been conducted on GRs and WMAs. This article assesses the entrance fees in GRs and WMAs, by comparing them with equivalent fees charged in Tanzania (at national parks and the Ngorongoro Crater and also with regional protected areas in Botswana, Kenya, Namibia, South Africa and Zimbabwe. Based on 28 semi-structured interviews with key stakeholder institutions working on tourism and conservation and more than 50 online survey responses from Tanzanian tourism operators, the research reviews local opinion and issues relating to adjusting current entrance fees. The article considers that while one objective for generating revenue from entrance fees is for conservation management, it is difficult to establish appropriate fees where there are gaps in knowledge about existing levels of visitation, tourism revenue and associated management costs. Conservation implications: This article has implications for protected area management practices, as it provides information on processes by which managers can review and revise entrance fee values.

  13. Convergent evolution: floral guides, stingless bee nest entrances, and insectivorous pitchers

    Science.gov (United States)

    Biesmeijer, Jacobus C.; Giurfa, Martin; Koedam, Dirk; Potts, Simon G.; Joel, Daniel M.; Dafni, Amots

    2005-09-01

    Several recent hypotheses, including sensory drive and sensory exploitation, suggest that receiver biases may drive selection of biological signals in the context of sexual selection. Here we suggest that a similar mechanism may have led to convergence of patterns in flowers, stingless bee nest entrances, and pitchers of insectivorous plants. A survey of these non-related visual stimuli shows that they share features such as stripes, dark centre, and peripheral dots. Next, we experimentally show that in stingless bees the close-up approach to a flower is guided by dark centre preference. Moreover, in the approach towards their nest entrance, they have a spontaneous preference for entrance patterns containing a dark centre and disrupted ornamentation. Together with existing empirical evidence on the honeybee's and other insects’ orientation to flowers, this suggests that the signal receivers of the natural patterns we examined, mainly Hymenoptera, have spontaneous preferences for radiating stripes, dark centres, and peripheral dots. These receiver biases may have evolved in other behavioural contexts in the ancestors of Hymenoptera, but our findings suggest that they have triggered the convergent evolution of visual stimuli in floral guides, stingless bee nest entrances, and insectivorous pitchers.

  14. Factors Affecting Individual Education Demand at the Entrance to University: Adnan Menderes University Sample

    Science.gov (United States)

    Sarpkaya, Ruhi

    2010-01-01

    The aim of this research is to determine the factors affecting individual education demands at the entrance to university. The research is in survey model. The universe of the study consists of 1630 freshmen at the faculties and vocational schools of Adnan Menderes University, Aydin. 574 students from 7 schools were included in the sample. The…

  15. Correlation among High School Senior Students' Test Anxiety, Academic Performance and Points of University Entrance Exam

    Science.gov (United States)

    Karatas, Hakan; Alci, Bulent; Aydin, Hasan

    2013-01-01

    Test anxiety seems like a benign problem to some people, but it can be potentially serious when it leads to high levels of distress and academic failure. The aim of this study is to define the correlation among high school senior students' test anxiety, academic performance (GPA) and points of university entrance exam (UEE). The study group of…

  16. Family Background and Students' Achievement on a University Entrance Exam in Brazil

    Science.gov (United States)

    Guimaraes, Juliana; Sampaio, Breno

    2013-01-01

    This paper examines the determinants of students' performance on the entrance test at Universidade Federal de Pernambuco, Brazil. Particular attention is paid to the importance of family background variables, such as parents' education and family income, on students' performance and how they relate to the probability of attending public schools…

  17. Search for entrance-channel dependence in the population of superdeformed bands in {sup 191}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Soramel, F.; Khoo, T.L.; Janssens, R.V.F. [and others

    1995-08-01

    The population intensity of some SD bands in the mass 150 region were observed to depend on the mass symmetry of the entrance channel in the fusion reaction. The authors raised the possibility that the population of SD bands had a memory of the entrance channel. To check this interesting possibility, we made measurements of the population intensities of superdeformed (SD) bands in the {sup 160}Gd({sup 36}S,5n){sup 191}Hg and {sup 130}Te({sup 64}Ni,3n){sup 191}Hg reactions. To ensure that any observed effect was not due to a simple angular momentum difference in the entrance channels, we also measured the average entry points and spin distributions of normal and SD states in {sup 191}Hg in the two reactions. The entry points and spin distributions for {sup 191}Hg are the same and, indeed, so are the SD intensities in the two reactions. Hence, no entrance-channel effect is observed in the population of the SD band in {sup 191}Hg, in contrast with data for SD bands in the mass 150 regions. We suggest that the effect observed previously in the mass 150 region is due to an angular momentum effect. A letter reporting our results was submitted for publication.

  18. Boundary conditions for plasma fluid models at the magnetic presheath entrance

    International Nuclear Information System (INIS)

    Loizu, J.; Ricci, P.; Halpern, F. D.; Jolliet, S.

    2012-01-01

    The proper boundary conditions at the magnetic presheath entrance for plasma fluid turbulence models based on the drift approximation are derived, focusing on a weakly collisional plasma sheath with T i ≪T e and a magnetic field oblique to a totally absorbing wall. First, the location of the magnetic presheath entrance is rigorously derived. Then boundary conditions at the magnetic presheath entrance are analytically deduced for v ||i , v ||e , n, φ, T e , and for the vorticity ω=∇ ⊥ 2 φ. The effects of E × B and diamagnetic drifts on the boundary conditions are also investigated. Kinetic simulations are performed that confirm the analytical results. Finally, the new set of boundary conditions is implemented in a three-dimensional global fluid code for the simulation of plasma turbulence and, as an example, the results of a tokamak scrape-off layer simulation are discussed. The framework presented can be generalized to obtain boundary conditions at the magnetic presheath entrance in more complex scenarios.

  19. Learning (Not) to become a Teacher: A Qualitative Analysis of the Job Entrance Issue

    Science.gov (United States)

    Rots, Isabel; Kelchtermans, Geert; Aelterman, Antonia

    2012-01-01

    Reporting on 12 case studies of student teachers, this paper examines how experiences during teacher education affect graduates' decision on job entrance. Interpretative data-analysis reveals that powerful sources of the shift in motivation to enter teaching concern interactions in which the person of the teacher is at stake. These mainly involve…

  20. Prayer, Luck, and Spiritual Strength: The Desecularization of Entrance Examination Systems in East Asia.

    Science.gov (United States)

    Zeng, Kangmin

    1996-01-01

    The socioeconomic importance and fierce competition related to high school and university entrance examinations in Japan, Taiwan, and South Korea lead students and their parents to seek spiritual support through prayer and religious rituals. Japanese students leave donations and written prayers and promises to the gods at Shinto shrines…

  1. Patient and staff dose during hysterosalpinography

    International Nuclear Information System (INIS)

    Buls, N.; Osteaux, M.

    2001-01-01

    Hysterosalpingography (HSG) is a useful and widely employed technique which uses X-ray fluoroscopy to investigate the female genital tract. Fluoroscopy is assessed by a gynaecologist, a physician who is not always trained to work with ionising radiation. Dose-area product measurements in a group of 34 patients allowed an estimation of the median effective dose (0,83 mSv) and the median dose to the ovaries (1,63 mGy) of the patient per procedure. The dose to the staff was estimated using thermoluminescent dosimetry. The following median entrance surface doses were estimated per procedure: 0,22 mGy to the lens of the eye, 0,15 mGy to the neck at thyroid level and 0,19 mGy to the back of the hand. The annual eye dose limit could be exceeded if the gynaecologist is a member of the public. (author)

  2. Patient radiation dose in conventional and xerographic cephalography

    International Nuclear Information System (INIS)

    Copley, R.L.; Glaze, S.A.; Bushong, S.C.; West, D.C.

    1979-01-01

    A comparison of the radiation doses for xeroradiographic and conventional film screen cephalography was made. Alderson tissue-equivalent phantoms were used for patient simulation. An optimum technique in terms of patient dose and image quality indicated that the dose for the Xerox process ranged from five to eleven times greater than that for the conventional process for entrance and exit exposures, respectively. This dose, however, falls within an acceptable range for other dental and medical radiation doses. It is recommended that conventional cephalography be used for routine purposes and that xeroradiography be reserved for situations requiring the increased image quality that the process affords

  3. Measurements and applications of dose indices in radiography

    International Nuclear Information System (INIS)

    Chen, T.R.; Tyan, Y.S.; Yang, J.J.; Shao, C.H.; Lin, J.Y.; Tung, C.J.

    2011-01-01

    Assessments of radiation dose and image quality are required in diagnostic radiography for quality assurance and optimization studies. In work currently being undertaken, dose indices were measured and image quality evaluated for a chest PA procedure. Thermoluminescent dosimeters of the GR-200 type were attached to the entrance and exit surfaces and placed at various depths of the PMMA phantom to measure the entrance surface dose, the exit surface dose, and the organ dose index. The effective dose was estimated from the entrance surface dose using PCXMC software. Two contrast-detail image plates, one with air holes for the low contrast objects and the other with gypsum holes for the high contrast objects, were used to obtain radiographic images. This image plate was placed at different depths from the entrance surface of the phantom to simulate objects at different positions in the body. Each image was evaluated by three independent radiologists to determine image quality. Analyses of radiation dose versus image quality were performed to determine the optimal technical factors such as, filtration and tube potential. It was found that an 11-cm thick PMMA phantom best simulated the patients. The fractional dose backscattered from this phantom was between 22% and 27% for kVp’s between 66 and 133. Optimization analyses showed that no extra filter was required. For low contrast objects, an optimal choice of tube potential was 120 kVp. For high contrast objects, a kVp as low as 77 kVp could be used, depending on the image quality requirement.

  4. 33 CFR 334.840 - Waters of Lake Michigan south of Northerly Island at entrance to Burnham Park Yacht Harbor...

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Waters of Lake Michigan south of Northerly Island at entrance to Burnham Park Yacht Harbor, Chicago, Ill.; danger zone adjacent to airport on... Michigan south of Northerly Island at entrance to Burnham Park Yacht Harbor, Chicago, Ill.; danger zone...

  5. Comparative Analysis of Water Quality between the Runoff Entrance and Middle of Recycling Irrigation Reservoirs

    Directory of Open Access Journals (Sweden)

    Haibo Zhang

    2015-07-01

    Full Text Available Recycling irrigation reservoirs (RIRs are an emerging aquatic ecosystem of critical importance, for conserving and protecting increasingly scarce water resources. Here, we compare water quality between runoff entrance and middle of four RIRs in nurseries in Virginia (VA and Maryland (MD. Surface water temperature (T and oxidation-reduction potential (ORP were lower in the middle than at the entrance, while the trend was opposite for dissolved oxygen (DO, pH and chlorophyll a (Chla. The magnitude of these differences between the entrance and middle decreased with increasing depth. These differences were magnified by water stratification from April to October. Minimum differences were observed for electrical conductivity (EC, total dissolved solids (TDS and turbidity (TUR. Cluster analyses were performed on water quality difference data to evaluate whether the differences vary with respect to reservoirs. Two clusters were formed with one consisting primarily of VA reservoirs, and the other consisting mostly of MD reservoirs in both years. Water quality in the middle and at the entrance of RIRs was expected to vary greatly because of runoff inflow. The two-point water quality differences observed here, although statistically significant, are not large enough to cause significant impact on crop health and productivity for most water quality parameters except pH. Additional analysis of outlet data shows that the range and magnitude of water quality difference between the middle and the outlet are comparable to those between the middle and entrance of RIRs. These results indicate that monitoring at a single point is sufficient to obtain reliable water quality estimates for most water quality parameters in RIRs except pH. This is important when considering the cost of labor and equipment necessary for documenting water quality in agricultural production systems. However, additional pH measurements are still necessary to make practical water quality

  6. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection.

    Science.gov (United States)

    Taghavi Zenouz, Ali; Ebrahimi, Hooman; Mahdipour, Masoumeh; Pourshahidi, Sara; Amini, Parisa; Vatankhah, Mahdi

    2008-01-01

    Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127) and between right and left injection sites (P = 0.778). According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  7. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection

    Directory of Open Access Journals (Sweden)

    Sara Pourshahidi

    2008-04-01

    Full Text Available

    Background and aims. Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections.

    Materials and methods. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test.

    Results. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127 and between right and left injection sites (P = 0.778.

    Conclusion. According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  8. Conversion coefficients for determining organ doses in paediatric spine radiography

    Energy Technology Data Exchange (ETDEWEB)

    Seidenbusch, Michael; Schneider, Karl [Ludwig-Maximilians-University of Munich, Institute of Clinical Radiology - Paediatric Radiology, Muenchen (Germany)

    2014-04-15

    Knowledge of organ and effective doses achieved during paediatric x-ray examinations is an important prerequisite for assessment of radiation burden to the patient. Conversion coefficients for reconstruction of organ and effective doses from entrance doses for segmental spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional segmental spine radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation field settings. Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during cervical, thoracic and lumbar spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal and lateral beam projections and the standard focus detector distance of 115 cm. The conversion coefficients presented may be used for organ dose assessments from entrance doses measured during spine radiographs of patients of all age groups and all field settings within the optimal and suboptimal standard field settings. (orig.)

  9. Radiation dose to neonates on a Special Care Baby Unit

    International Nuclear Information System (INIS)

    Faulkner, K.; Barry, J.L.; Smalley, P.

    1989-01-01

    The skin entrance dose to neonates on a special care baby unit was estimated from a knowledge of the technique factors, X-ray tube output and backscatter factors. Normalized organ dose data were employed to estimate radiation dose to a number of critical organs. Methods of reducing radiation dose to neonates were investigated. Initially, this involved changing the radiographic technique factors and introducing a lead rubber adjustable collimator, placed on top of the incubator, in addition to light beam diaphragms on the X-ray tube. These modifications to the examination technique appeared to reduce average entrance dose per radiograph from 92 μGy, to 58 μGy, a reduction of 37%. Later, a rare-earth film-screen combination was introduced to replace existing fast calcium tungstate screens. This enabled average entrance dose per radiograph to be reduced to 39 μGy, a further reduction of 33%. The mean radiation dose to a neonate is mainly determined by the number of radiographs. (author)

  10. Radiation dose to neonates on a Special Care Baby Unit

    Energy Technology Data Exchange (ETDEWEB)

    Faulkner, K.; Barry, J.L.; Smalley, P.

    1989-03-01

    The skin entrance dose to neonates on a special care baby unit was estimated from a knowledge of the technique factors, X-ray tube output and backscatter factors. Normalized organ dose data were employed to estimate radiation dose to a number of critical organs. Methods of reducing radiation dose to neonates were investigated. Initially, this involved changing the radiographic technique factors and introducing a lead rubber adjustable collimator, placed on top of the incubator, in addition to light beam diaphragms on the X-ray tube. These modifications to the examination technique appeared to reduce average entrance dose per radiograph from 92 ..mu..Gy, to 58 ..mu..Gy, a reduction of 37%. Later, a rare-earth film-screen combination was introduced to replace existing fast calcium tungstate screens. This enabled average entrance dose per radiograph to be reduced to 39 ..mu..Gy, a further reduction of 33%. The mean radiation dose to a neonate is mainly determined by the number of radiographs.

  11. Patient dose in neonatal units

    International Nuclear Information System (INIS)

    Smans, K.; Struelens, L.; Smet, M.; Bosmans, H.; Vanhavere, F.

    2008-01-01

    Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a significant radiation detriment. Hence, knowledge of the patient dose is necessary to justify the exposures. A study to assess the patient doses was started at the neonatal intensive care unit (NICU) of the Univ. Hospital in Leuven. Between September 2004 and September 2005, prematurely born babies underwent on average 10 X-ray examinations in the NICU. In this sample, the maximum was 78 X-ray examinations. For chest radiographs, the median entrance skin dose was 34 μGy and the median dose area product was 7.1 mGy.cm 2 . By means of conversion coefficients, the measured values were converted to organ doses. Organ doses were calculated for three different weight classes: extremely low birth weight infants ( 2500 g). The doses to the lungs for a single chest radiograph for infants with extremely low birth weights, low birth weights and normal birth weights were 24, 25 and 32 μGy, respectively. (authors)

  12. Patient dose, gray level and exposure index with a computed radiography system

    Science.gov (United States)

    Silva, T. R.; Yoshimura, E. M.

    2014-02-01

    Computed radiography (CR) is gradually replacing conventional screen-film system in Brazil. To assess image quality, manufactures provide the calculation of an exposure index through the acquisition software of the CR system. The objective of this study is to verify if the CR image can be used as an evaluator of patient absorbed dose too, through a relationship between the entrance skin dose and the exposure index or the gray level values obtained in the image. The CR system used for this study (Agfa model 30-X with NX acquisition software) calculates an exposure index called Log of the Median (lgM), related to the absorbed dose to the IP. The lgM value depends on the average gray level (called Scan Average Level (SAL)) of the segmented pixel value histogram of the whole image. A Rando male phantom was used to simulate a human body (chest and head), and was irradiated with an X-ray equipment, using usual radiologic techniques for chest exams. Thermoluminescent dosimeters (LiF, TLD100) were used to evaluate entrance skin dose and exit dose. The results showed a logarithm relation between entrance dose and SAL in the image center, regardless of the beam filtration. The exposure index varies linearly with the entrance dose, but the angular coefficient is beam quality dependent. We conclude that, with an adequate calibration, the CR system can be used to evaluate the patient absorbed dose.

  13. Staphylococcus aureus CC30 Lineage and Absence of sed,j,r-Harboring Plasmid Predict Embolism in Infective Endocarditis

    Directory of Open Access Journals (Sweden)

    Jean-Philippe Rasigade

    2018-06-01

    Full Text Available Staphylococcus aureus induces severe infective endocarditis (IE where embolic complications are a major cause of death. Risk factors for embolism have been reported such as a younger age or larger IE vegetations, while methicillin resistance conferred by the mecA gene appeared as a protective factor. It is unclear, however, whether embolism is influenced by other S. aureus characteristics such as clonal complex (CC or virulence pattern. We examined clinical and microbiological predictors of embolism in a prospective multicentric cohort of 98 French patients with monomicrobial S. aureus IE. The genomic contents of causative isolates were characterized using DNA array. To preserve statistical power, genotypic predictors were restricted to CC, secreted virulence factors and virulence regulators. Multivariate regularized logistic regression identified three independent predictors of embolism. Patients at higher risk were younger than the cohort median age of 62.5 y (adjusted odds ratio [OR] 0.14; 95% confidence interval [CI] 0.05–0.36. S. aureus characteristics predicting embolism were a CC30 genetic background (adjusted OR 9.734; 95% CI 1.53–192.8 and the absence of pIB485-like plasmid-borne enterotoxin-encoding genes sed, sej, and ser (sedjr; adjusted OR 0.07; 95% CI 0.004–0.457. CC30 S. aureus has been repeatedly reported to exhibit enhanced fitness in bloodstream infections, which might impact its ability to cause embolism. sedjr-encoded enterotoxins, whose superantigenic activity is unlikely to protect against embolism, possibly acted as a proxy to others genes of the pIB485-like plasmid found in genetically unrelated isolates from mostly embolism-free patients. mecA did not independently predict embolism but was strongly associated with sedjr. This mecA-sedjr association might have driven previous reports of a negative association of mecA and embolism. Collectively, our results suggest that the influence of S. aureus genotypic features

  14. Determination of Doses for X-Ray Examinations of Paranasal Sinuses of Children

    International Nuclear Information System (INIS)

    Milkovic, D.; Miljanic, S.; Knezevic, Z.; Ranogajec-Komor, M.; Beck, N; Zagar, I.

    2013-01-01

    The knowledge of the absorbed doses during X-ray examination is very important, especially in paediatric radiology in order to improve radiation protection. In childhood, the paranasal sinuses diseases are very frequent and the development of sinuses has some specialities which has to be taken into consideration in X-ray diagnostics. The aim of this work was the determination of the relative doses on the thyroid gland and eyes, in respect to the entrance dose on the anthropomorphic child phantom (CIRS). The entrance doses on the phantom to the entrance dose on patients of similar age. Simultaneously the influence of human working method was studied, i.e. the performance of the radiological technicians. The age of the patients varied from 7 to 15 years, the child phantom was equivalent to 10 years age. A protective lead apron on the necks of both children and phantom was used. Doses were measured with radiophotoluminescence (RPL) and thermoluminescence (TL) dosemeters. The mean doses on the thyroid and the eyes measured in the phantom after 10 expositions were 0.20 ± 0.05 mSv, and 0.32 ± 0.02 mSv, respectively. Relative doses were calculated in relation to entrance dose of 9.96 mSv for 10 exposures, and the results were 0.02 and 0.03 for the thyroid gland and the eyes, respectively. The dosimetry results on 45 patients showed that there was a good correlation between measured doses and the body mass index (BMI). The mean entrance dose measured on the 45 patients was 0.97 ± 0.08 mSv.(author)

  15. Defining a Structural Model for the Revitalization of the Lost Urban Spaces (City Entrances in Contemporary Urban Design Case Study: Entrance of Sanandaj

    Directory of Open Access Journals (Sweden)

    Seyed Mohammadreza Khatibi

    2015-09-01

    Full Text Available Not long ago, city gates and entryways had high spatial value and were among the landmarks for marking city boundaries. Today with cities having been expanded and developed, such aspect of the entrance concept is lost and entryways are turned to passages for transportation. In fact, the rich spatial value of such entrances has decreased as they are solely spaces for passing through out or into the city. The dissonant expansion of entryways causes irregularities in thresholds of urban structure. This is due to imprudent intrusion into city landscape entailed by ill-considered planning activities. The main problem is the lack of comprehensive visual or mental definitions in the field. In other words, the challenge includes improper sequencing, zoning, and lack of lucid scenario and interfere procedure. Through defining a scenario, this study aims to set a spatial hierarchy for urban entryways. It then uses a comparative study to examine the scenario for an existing case study. This study provides a new definition for designing and planning for the fields concerned with city entryways. This implies methods by which authorities can interfere in the process of urban design.

  16. Field study to evaluate radiation doses in dental practices

    International Nuclear Information System (INIS)

    Panzer, W.; Scheurer, C.

    1984-05-01

    An inexpensive and simple test device was developed and used in a field study to evaluate entrance dose, dose to an intra-oral film, filtration and field size under routine conditions in more than 150 dental practices. The test device consists of two films of different speed and a set of 5 thin copper filters for a filter analytical determination of the radiation quality. Dentists voluntarily participating in the study were asked to expose the test device like they usually do when examining a molar tooth. The main result was the evidence of a significant dose reduction compared to the findings of similar studies performed in 1970 and 1976. This reduction is due to a general shift to lower values and a complete disappearance of values above 45 mGy (5 R) which in 1970 were still more than 15%. In the same way the number of facilities showing insufficient filtration or collimation had decreased. Nevertheless, a large spread of dose values could still be observed, ranging from less than 0.45 mGy (50 mR) to more than 26 mGy (3 R), for the entrance dose. The most striking result, however, was that such an important parameter like the speed of the films used at the respective unit turned out to have no impact on the entrance dose. (orig./HP)

  17. Eight New Luminous z > 6 Quasars Selected via SED Model Fitting of VISTA, WISE and Dark Energy Survey Year 1 Observations

    Energy Technology Data Exchange (ETDEWEB)

    Reed, S.L.; et al.

    2017-01-17

    We present the discovery and spectroscopic confirmation with the ESO NTT and Gemini South telescopes of eight new 6.0 < z < 6.5 quasars with z$_{AB}$ < 21.0. These quasars were photometrically selected without any star-galaxy morphological criteria from 1533 deg$^{2}$ using SED model fitting to photometric data from the Dark Energy Survey (g, r, i, z, Y), the VISTA Hemisphere Survey (J, H, K) and the Wide-Field Infrared Survey Explorer (W1, W2). The photometric data was fitted with a grid of quasar model SEDs with redshift dependent Lyman-{\\alpha} forest absorption and a range of intrinsic reddening as well as a series of low mass cool star models. Candidates were ranked using on a SED-model based $\\chi^{2}$-statistic, which is extendable to other future imaging surveys (e.g. LSST, Euclid). Our spectral confirmation success rate is 100% without the need for follow-up photometric observations as used in other studies of this type. Combined with automatic removal of the main types of non-astrophysical contaminants the method allows large data sets to be processed without human intervention and without being over run by spurious false candidates. We also present a robust parametric redshift estimating technique that gives comparable accuracy to MgII and CO based redshift estimators. We find two z $\\sim$ 6.2 quasars with HII near zone sizes < 3 proper Mpc which could indicate that these quasars may be young with ages < 10$^6$ - 10$^7$ years or lie in over dense regions of the IGM. The z = 6.5 quasar VDESJ0224-4711 has J$_{AB}$ = 19.75 is the second most luminous quasar known with z > 6.5.

  18. Eight new luminous z ≥ 6 quasars discovered via SED model fitting of VISTA, WISE and Dark Energy Survey Year 1 observations

    International Nuclear Information System (INIS)

    Reed, S. L.; McMahon, R. G.; Martini, P.; Banerji, M.; Auger, M.

    2017-01-01

    Here, we present the discovery and spectroscopic confirmation with the European Southern Observatory New Technology Telescope (NTT) and Gemini South telescopes of eight new, and the rediscovery of two previously known, 6.0 < z < 6.5 quasars with zAB < 21.0. These quasars were photometrically selected without any morphological criteria from 1533 deg2 using spectral energy distribution (SED) model fitting to photometric data from Dark Energy Survey (g, r, i, z, Y), VISTA Hemisphere Survey (J, H, K) and Wide-field Infrared Survey Explorer (W1, W2). The photometric data were fitted with a grid of quasar model SEDs with redshift-dependent Ly α forest absorption and a range of intrinsic reddening as well as a series of low-mass cool star models. Candidates were ranked using an SED-model-based χ2-statistic, which is extendable to other future imaging surveys (e.g. LSST and Euclid). Our spectral confirmation success rate is 100 per cent without the need for follow-up photometric observations as used in other studies of this type. Combined with automatic removal of the main types of non-astrophysical contaminants, the method allows large data sets to be processed without human intervention and without being overrun by spurious false candidates. We also present a robust parametric redshift estimator that gives comparable accuracy to Mg ii and CO-based redshift estimators. We find two z ~6.2 quasars with H ii near zone sizes ≤3 proper Mpc that could indicate that these quasars may be young with ages ≲ 10 6 -10 7 years or lie in over dense regions of the IGM. The z = 6.5 quasar VDES J0224–4711 has JAB = 19.75 and is the second most luminous quasar known with z ≥ 6.5.

  19. Population dose assessment from radiodiagnosis in Portugal

    International Nuclear Information System (INIS)

    Serro, R.; Carreiro, J.V.; Galvao, J.P.; Reis, R.

    1992-01-01

    A survey of radiodiagnostic installations was carried out in Portugal covering 75 premises including public hospitals, local and regional public health centres. A total of 175 X ray tubes was surveyed using the new NEXT methodology covering data on premises, tube and operator, and projection. Average value of voltage, current-time product, HVL, ratio of beam area to film area and source to film distance for the eleven most frequent projections are reported as well as the skin entrance exposure and the doses to some organs. The weighted average dose values per projection and for the different organs allowed an estimate of the whole-body dose per caput. From the gonadal doses the genetic significant dose was also estimated

  20. Safety Evaluation of the Lighting at the Entrance of a Very Long Road Tunnel: A Case Study in Ilam.

    Science.gov (United States)

    Mehri, Ahmad; Hajizadeh, Roohalah; Farhang Dehghan, Somayeh; Nassiri, Parvin; Jafari, Sayed Mohammad; Taheri, Fereshteh; Zakerian, Seyed Abolfazl

    2017-06-01

    At the entrance of a tunnel, reflection of sunlight from the surrounding environment and a lack of adequate lighting usually cause some vision problems. The purpose of this study was to perform a safety evaluation of lighting on a very long road in Ilam, Iran. The average luminance was measured using a luminance meter (model S3; Hagner, Solna, Sweden). A camera (model 108, 35-mm single-lens reflex; Yashica, Nagano, Japan) was used to take photographs of the safe stopping distance from the tunnel entrance. Equivalent luminance was determined according to the Holliday polar diagram. Considering the average luminance at the tunnel entrance (116.7 cd/m 2 ) and using Adrian's equation, the safe level of lighting at the entrance of the tunnel was determined to be 0.7. A comparison between the results of the safe levels of lighting at the entrance of the tunnel and the De Boer scale showed that the phenomenon of black holes is created at the tunnel entrance. This may lead to a misadaptation of the drivers' eyes to the change in luminance level at the entrance of the tunnel, thereby increasing the risk of road accidents in this zone.

  1. Evaluation of occupational and patient radiation doses in orthopedic surgery

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Habeeballa, B.; Osman, H.; Abdelaziz, I.; Sassi, S.A.; Sam, A.K.

    2015-01-01

    This study intends to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (DHS) and (ii) Dynamic Cannula Screw (DCS) and to evaluate entrance surface Air kerma (ESAK) dose and organ doses and effective doses. Calibrated Thermoluminescence dosimeters (TLD-GR200A) were used. The mean patients’ doses were 0.46 mGy and 0.07 mGy for DHS and DCS procedures, respectively. The mean staff doses at the thyroid and chest were 4.69 mGy and 1.21 mGy per procedure. The mean organ and effective dose for patients and staff were higher in DHS compared to DCS. Orthopedic surgeons were exposed to unnecessary radiation doses due to the lack of protection measures. The radiation dose per hip procedure is within the safety limit and less than the previous studies

  2. Calculation of the uncertainty associated to the result of entrance surface air kerma for conventional radiology patients

    International Nuclear Information System (INIS)

    Blanco, D.; Mora, P.; Khoury, H.; Fabri, D.; Leyton, F.; Cardenas, J.; Blanco, S.; Kodlulovich, S.; Roas, N.; Benavente, T.; Ortiz Lopez, P.; Ramirez, R.

    2008-01-01

    Radiation doses from diagnostic radiology are the largest contribution to the collective dose and the use of guidance (reference levels) has proven to be a tool for optimization of protection. Recently, with the support of the International Atomic Energy Agency (IAEA), eight countries of the Latin-American region have been working together on a programme to test methodologies for determining preliminary values of guidance levels for X-ray chest, lumbar spine and breast examinations. The approach used was to obtain entrance surface air kerma from measurements of X-ray tube outputs, corrected for distance and backscatter and later for real exposure parameters used with patients. For quality control, some of these values for a reduced number of patients were compared with direct TLD measurements directly placed on the patient during exposure. Given the number of parameters involved in the two methods, relatively large differences are deemed to be found in the comparison. The only way of deciding if measurements and calculations are outliers, for example, due to a systematic error or a mistake, is to compare these differences with the combined uncertainty. The aim of this paper is to present (in a detailed way) the methodology used in the pilot program ARCAL LXXV, the analyses of data performed within the survey and the estimated uncertainty. The parameters analyzed were: precision of the readings, positioning of the detector, reproducibility of the mAs and kV, long term stability of the instrument, radiation quality, kerma rate, radiation incidence, field size and field homogeneity, calibration factor of the equipment, temperature and pressure measurement, X-ray tube output curve adjustment, backscatter factor and focus-patient distance. The combined standard uncertainty for Ke in chest radiography in adult patients of standard complexion, was 12%, and the expanded uncertainty (k=2) was 24%. (author)

  3. Creation and clinical application of real-time dose monitor using dose area product meter

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Uoyama, Yoshinori; Iida, Hiroji; Mizushima, Takashi

    2004-01-01

    The management of patient dose has become more of an issue in recent years. Dose can be determined non-invasively and in real time through the use of a dose area product meter, but it is the area dose value that is obtained. Therefore, we created a program that estimates entrance skin dose (ESD) in real time from area dose values obtained during procedures. We used Microsoft Visual C++ 6.0 (Standard Edition) for the programming language and C language for the programming environment. The value was a maximum 285.4 mGy at ileus tube insertion when measuring ESD for radiography of the digestive organ and non-vascular type interventional radiology (IVR) using the created program and seeking the average according to the procedures. The program that we created can be considered valid for monitoring ESD correctly and in real time. (author)

  4. Paid parental leave to immigrants: An obstacle to labor market entrance?

    OpenAIRE

    Vikman, Ulrika

    2013-01-01

    This paper evaluates how access to paid parental leave affects labor market entrance for immigrating mothers with small children. Paid parental leave together with job protection may increase labor force participation among women but if it is too generous it may create incentives to stay out of the labor force. This incentive effect may be especially true for mothers immigrating to a country where having small children automatically makes the mothers eligible for the benefit. To evaluate the ...

  5. Search for entrance channel effects in fusion reactions via neutron evaporation

    International Nuclear Information System (INIS)

    Ajay Kumar; Kaur, J.; Kumar, A.; Singh, G.; Govil, I.M.; Rakesh Kumar; Datta, S.K.; Chatterjee, M.B.; Yogi, B.K.

    2001-01-01

    It is generally expected that the compound nuclei formed at the given excitation energies and the angular momenta follow a statistical decay pattern independent of a particular reaction that led to fusion. In order to search the entrance channel effects in the decay of compound nucleus, the reaction 16 O + 64 Zn at oxygen beam energy of 91 MeV and 95 MeV are investigated

  6. A conserved chloramphenicol binding site at the entrance to the ribosomal peptide exit tunnel

    DEFF Research Database (Denmark)

    Long, Katherine S; Porse, Bo T

    2003-01-01

    , of E.coli 23S rRNA and G2084 (2058 in E.coli numbering) in domain V of H.halobium 23S rRNA. The modification sites overlap with a portion of the macrolide binding site and cluster at the entrance to the peptide exit tunnel. The data correlate with the recently reported chloramphenicol binding site...... on an archaeal ribosome and suggest that a similar binding site is present on the E.coli ribosome....

  7. Paternal Genetic Structure of Hainan Aborigines Isolated at the Entrance to East Asia

    Science.gov (United States)

    Li, Dongna; Li, Hui; Ou, Caiying; Lu, Yan; Sun, Yuantian; Yang, Bo; Qin, Zhendong; Zhou, Zhenjian; Li, Shilin; Jin, Li

    2008-01-01

    Background At the southern entrance to East Asia, early population migration has affected most of the Y-chromosome variations of East Asians. Methodology/Principal Findings To assess the isolated genetic structure of Hainan Island and the original genetic structure at the southern entrance, we studied the Y chromosome diversity of 405 Hainan Island aborigines from all the six populations, who have little influence of the recent mainland population relocations and admixtures. Here we report that haplogroups O1a* and O2a* are dominant among Hainan aborigines. In addition, the frequency of the mainland dominant haplogroup O3 is quite low among these aborigines, indicating that they have lived rather isolated. Clustering analyses suggests that the Hainan aborigines have been segregated since about 20 thousand years ago, after two dominant haplogroups entered East Asia (31 to 36 thousand years ago). Conclusions/Significance Our results suggest that Hainan aborigines have been isolated at the entrance to East Asia for about 20 thousand years, whose distinctive genetic characteristics could be used as important controls in many population genetic studies. PMID:18478090

  8. Radiotherapy verification film for estimating cumulative entrance skin exposure for fluoroscopic examinations

    International Nuclear Information System (INIS)

    Geise, R.A.; Ansel, H.J.

    1990-01-01

    Measurement of skin entrance exposures during fluoroscopic procedures is complicated by the use of automatic exposure control devices and the presence of contrast media. Due to variability in positioning spot films from patient to patient, standard dosimeters, such as thermoluminescent, cannot be properly placed on the skin prior to examination. Prepackaged film of the type used for portal verification in radiation therapy held next to the patient's skin in a specially modified patient examination gown was found to be useful for determining the entrance skin exposure from both fluoroscopy and spot films during air contrast barium enema exams. The usable sensitivity range of this film has been found satisfactory for exposure measurements at exposures and kVps typically used for gastrointestinal fluoroscopic procedures. Errors in exposure estimates due to changes in film speed and contrast with kVp are less than 5% for the range of kVps used. Errors from variations in beam quality due to the adjacency of scattering material are approximately 5%. Entrance exposures determined with film agreed with those determined from TLD measurements to within 21%, with an average difference of 9%

  9. Lattice Boltzmann Simulation of the Hydrodynamic Entrance Region of Rectangular Microchannels in the Slip Regime

    Directory of Open Access Journals (Sweden)

    Niya Ma

    2018-02-01

    Full Text Available Developing a three-dimensional laminar flow in the entrance region of rectangular microchannels has been investigated in this paper. When the hydrodynamic development length is the same magnitude as the microchannel length, entrance effects have to be taken into account, especially in relatively short ducts. Simultaneously, there are a variety of non-continuum or rarefaction effects, such as velocity slip and temperature jump. The available data in the literature appearing on this issue is quite limited, the available study is the semi-theoretical approximate model to predict pressure drop of developing slip flow in rectangular microchannels with different aspect ratios. In this paper, we apply the lattice Boltzmann equation method (LBE to investigate the developing slip flow through a rectangular microchannel. The effects of the Reynolds number (1 < Re < 1000, channel aspect ratio (0 < ε < 1, and Knudsen number (0.001 < Kn < 0.1 on the dimensionless hydrodynamic entrance length, and the apparent friction factor, and Reynolds number product, are examined in detail. The numerical solution of LBM can recover excellent agreement with the available data in the literature, which proves its accuracy in capturing fundamental fluid characteristics in the slip-flow regime.

  10. A new approach and computational algorithm for sensitivity/uncertainty analysis for SED and SAD with applications to beryllium integral experiments

    International Nuclear Information System (INIS)

    Song, P.M.; Youssef, M.Z.; Abdou, M.A.

    1993-01-01

    A new approach for treating the sensitivity and uncertainty in the secondary energy distribution (SED) and the secondary angular distribution (SAD) has been developed, and the existing two-dimensional sensitivity/uncertainty analysis code, FORSS, was expanded to incorporate the new approach. The calculational algorithm was applied to the 9 Be(n,2n) cross section to study the effect of the current uncertainties in the SED and SAD of neutrons emitted from this reaction on the prediction accuracy of the tritium production rate from 6 Li(T 6 ) and 7 Li(T 7 ) in an engineering-oriented fusion integral experiment of the US Department of Energy/Japan Atomic Energy Research Institute Collaborative Program on Fusion Neutronics in which beryllium was used as a neutron multiplier. In addition, the analysis was extended to include the uncertainties in the integrated smooth cross sections of beryllium and other materials that constituted the test assembly used in the experiment. This comprehensive two-dimensional cross-section sensitivity/uncertainty analysis aimed at identifying the sources of discrepancies between calculated and measured values for T 6 and T 7

  11. Investigation on 3D dose distribution in digital breast tomosynthesis

    Science.gov (United States)

    Masi, M.

    2017-03-01

    Monte Carlo calculations for dosimetry in digital breast tomosynthesis (DBT) require experimental validations. We measured the 3D dose distribution in a breast phantom in a DBT scan, using XR-QA2 radiochromic films. We positioned film pieces at the entrance surface, at the bottom surface and at four depths between adjacent slabs in the 5-slabs, 5-cm-thick phantom simulating a compressed breast with 50% glandular fraction. We irradiated the phantom at 40kV (half value layer 1.1mm Al) for three angular tilting of the beam central axis ( {±}25° and 0° normal incidence). We determined the transverse and longitudinal distributions of the average dose in the phantom (in terms of air kerma normalized to the entrance air kerma), showing the angular dependence of the depth-resolved 3D dose distributions. In transverse planes the maximum dose variations were between 5.0% and 14.8% for normal incidence, and by 8.6% from the central to the tilted view. In the direction of the beam axis, the dose decreases up to about 71% from the entrance to the exit value. The extimated backscatter fraction was between 3% and 8%.

  12. Evaluation of entrance skin air kerma in digital and conventional pediatric chest examinations performed in Parana-Brazil

    International Nuclear Information System (INIS)

    Oliveira, Ana L.R.; Schelin, Hugo R.; Lunelli, Neuri; Paschuk, Sergei; Tilly Jr, Joao G.; Rogacheski, Enio; Khoury, Helen J.; Ferreira, Jose R.L.

    2008-01-01

    Full text: In pediatric radiology it is important to evaluate patient exposure due to the high sensitivity of his/her tissue and his/her relatively longer life expectancy, which may increase the chance of radiogenic cancer development. Special attention is necessary when digital systems are used since a high dosage level for the patient may go unnoticed because the resulting image is not overexposed. The purpose of this work is to evaluate the Entrance Skin Air Kerma (ESAK) in pediatric patients submitted to digital and conventional chest examinations performed in the State of Parana, located in the Southern region of Brazil. The survey was performed in two hospitals, one located in Curitiba, the Capital of the State (A) and the other in the city of Cascavel (B). Hospital A uses a conventional image system and Hospital B uses a CR digital system. The study group consisted of 50 patients (from 2 days to six years of age) undergoing chest PA/AP examinations. At the time of the examination, the exposure parameters (kV, mAs, focal-film distance, etc) and the gender, height, weight and age of the patient were recorded. To evaluate the Entrance Skin Air Kerma (ESAK), two TLD-100 dosimeters were packaged in a polyethylene case, heat sealed and placed on the surface of each patient. The TLDs were calibrated the Metrology Laboratory of Ionizing Radiation of the Federal University of Pernambuco. The TLDs were processed on a Victoreen readout system model 2800M. The results showed that the kilovoltage values used in Hospital A are in the range of 46 to 65 kV with the average value of 51,7 kV, while the ones in Hospital B are in the range of 65 to 80 kV. On the other hand, even though hospital B uses the CR system, the mAs used for the chest exams are 4 times higher than the ones used in Hospital A. For Hospital A, the mean ESAK value was 0.044 mGy (min: 0.08 and max 0.146 mGy), and for Hospital B the mean ESAK value was 0.368 mGy (min: 0.021 and max 1.21mGy). The results made

  13. Wave Climate and Littoral Sediment Transport Potential, Cape Fear River Entrance and Smith Island to Ocean Isle Beach, North Carolina

    National Research Council Canada - National Science Library

    Thompson, Edward

    1999-01-01

    Numerical model studies were conducted to assist the U.S. Army Engineer District, Wilmington, in evaluating potential plans for modifying the Cape Fear River entrance channel and in preparing General Reevaluation Reports...

  14. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography

    International Nuclear Information System (INIS)

    Lopes, Cintya Carolina Barbosa

    2006-04-01

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  15. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  16. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  17. Determination of effective dose in pediatric radiodiagnostic in Medellin-Colombia; Determinacion de la dosis efectiva en radiodiagnostico pediatrico en Medellin-Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Garzon, William J., E-mail: wjaramig@gmail.com [Instituto Tecnologico Metropolitano (ITM), Medellin (Colombia); Aramburo, Javier M.; Jimenez, Angelmiro A.; Ortiz, Anselmo P., E-mail: jmorales@unal.edu.co, E-mail: aarrieta@unal.edu.co, E-mail: japuerta@unal.edu.co [Universidad Nacional de Colombia (UNAL), Medellin (Colombia)

    2013-10-01

    In order to know the effective dose in pediatric X-ray exams of chest, entrance surface dose measurements were performed for ages 1,5 and 10 years in the largest pediatric hospital in the city of Medellin, Colombia. The effective dose was obtained from applying the conversion coefficients to measures of the entrance surface dose (ESD) in 306 radiographic studies in AP and LAT I projections. The results were validated with PCXMC 2.0 computer program and other work reported in the literature. (author)

  18. Relationship medical exposure in X-ray diagnosis and loading factor and film/screen system for reduction exposure dose in Aomori. An analysis based on the results of questionnaire

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    A fact-finding questionnaire survey on medical exposure in Aomori Prefecture was conducted in September 1998. Of the 23 exposed sites in the body investigated, exposure at 17 sites in adults was investigated in terms of the type of high-voltage generator, imaging conditions (X-ray tube voltage, electric current, exposure time, etc.), photosensitive materials and relative photosensitivity, and entrance surface doses. At 6 of the 17 exposed sites, the relationships between these technical conditions and entrance surface doses were analyzed to consider further reduction of medical exposure. The most frequently used high-voltage generators were inverter generators (about 52%). In many institutions, additional filters were utilized for high-voltage imaging of the chest. Highly sensitive green-emission materials were the most frequently used photosensitive materials (73%). These findings indicate that many institutions are attempting to reduce exposure. Entrance surface doses varied greatly among institutions: and a 100-fold difference was observed in exposure to the chest, Martius, and the pelvis. Further efforts to lower entrance surface doses are therefore necessary to reduce medical exposure. Negative correlations were observed between electric voltage, electric current, and exposure time. Examination of the relationships between entrance surface doses, electric current, and exposure time yielded positive correlations. However, the entrance surface doses may not have been properly calculated in some institutions, and examination of the relationship between the relative sensitivity of the sensitive material and entrance surface doses showed great variability in entrance surface doses between institutions. Based on the above results, it is concluded that further reduction of medical exposure is possible, not only by improving the accuracy of X-ray units/devices, but by choosing a more appropriate of conditions to perform radiography. (K.H.)

  19. Study of mass asymmetry effect in the entrance channel for deep inelastic collisions between heavy ions

    International Nuclear Information System (INIS)

    Agarwal, S.K.

    1980-01-01

    The reactions ( 52 Cr+ 56 Fe) and ( 16 O+ 92 Mo) were studied extensively to learn about the influence of the mass asymmetry of the entrance channel on Deep Inelastic Collisions (DIC). These two systems have very different entrance channel asymmetry but both of them lead to the same ensemble of nucleons. The incident energies were choosen to be 265 MeV for Cr and 187 MeV for O so that the maximum angular momentum is the same in both the cases. The experimental results of the quasi-symmetric system (Cr+Fe) show that a large number of fragments have the characteristic properties of fission fragments. However, comparison of these results with those of an asymmetric system (O+Mo), forming the same compound nucleus with higher excitation energy, leads to think that these events can not be accounted for fission. It has been shown that these events could be considered as DIC products. The distributions of different multidifferential observables were reproduced with the help of a diffusion model, and with the condition of introducing a notion of half life time of the composite system. The half-life, thus calculated, seems to vary as a function of mass asymmetry of the entrance channel: 20.10 -22 S for the system Cr+Fe, 2.10 -22 S for the system O+Mo and 10.10 -22 S for a third system 20 Ca+ 64 Ni which has an intermediate mass asymmetry. Further it seems that the evaporation residue cross section in symmetric systems is far less than what we can expect from classical calculations [fr

  20. Reference doses and patient size in paediatric radiology

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.; Shrimpton, P.

    2000-01-01

    There is a wide range in patient size from a newborn baby to a 15 year old adolescent. Reference doses for paediatric radiology can sensibly be established only for specific sizes of children. Here five standard sizes have been chosen, representing 0 (newborn), 1, 5, 10 and 15 year old patients. This selection of standard ages has the advantage of matching the paediatric mathematical phantoms which are often used in Monte Carlo organ dose calculations. A method has been developed for calculating factors for normalising doses measured on individual children to those for the nearest standard-sized 'child'. These normalisation factors for entrance surface dose (ESD) and dose-area product (DAP) measurements depend on the thickness of the real child, the thickness of the nearest standard 'child', and an effective linear attenuation coefficient (μ) which is itself a function of the x-ray spectrum, the field size, and whether or not an antiscatter grid is used. Entrance and exit dose measurements were made with phantom material representing soft tissue to establish μ values for abdominal and head examinations, and with phantom material representing lung for chest examinations. These measurements of μ were confirmed and extended to other x-ray spectra and field sizes by Monte Carlo calculations. The normalisation factors are tabulated for ESD measurements for specific radiographic projections through the head and trunk, and for DAP measurements for complete multiprojection examinations in the trunk. The normalisation factors were applied to European survey data for entrance surface dose and dose-area product measurements to derive provisional reference doses for common radiographic projections and for micturating cystourethrography (MCU) examinations - the most frequent fluoroscopic examination on children. (author)

  1. Entrance channel dependent light-charged particle emission of the 156Er compound

    International Nuclear Information System (INIS)

    Liang, J.F.; Bierman, J.D.; Kelly, M.P.; Sonzogni, A.A.; Vandenbosch, R.; van Schagen, J.P.S.

    1996-01-01

    Light-charged particle decay from the 156 Er compound nucleus, populated by 12 C+ 144 Sm and 60 Ni+ 96 Zr at the same excitation energy, were measured in coincidence with the evaporation residues. The high energy slope of charged particle spectra for the 60 Ni-induced reaction is steeper than for the 12 C-induced reaction. Model calculations including particle evaporation during compound nucleus formation result in good agreement with the data. This suggests that the difference in the charged particle spectra between the two entrance channels is due to a longer formation time in the 60 Ni-induced reaction. 14 refs., 3 figs

  2. Fusion-fission of heavy systems: influence of the entrance channel mass assymmetry

    International Nuclear Information System (INIS)

    Rivet, M.F.; Alami, R.; Borderie, B.; Fuchs, H.; Gardes, D.; Gauvin, H.

    1988-02-01

    The influence of the entrance channel on fission processes was studied by forming the same composite system by two different target-projectile combinations ( 40 Ar + 209 Bi and 56 Fe + 187 Re, respectively). Compound nucleus fission and quasi fission were observed and the analysis was performed in the framework of the extra-extra-push model, which provides a qualitative interpretation of the results; limits for the extra-extra-push threshold are given, but problems with quantitative predictions for the extra-push are noted

  3. 35% of fracture in one of the Embalse nuclear power plant's entrance collectors

    International Nuclear Information System (INIS)

    Galia, A.V.; Marinucci, L.N.M.

    1987-01-01

    The purpose of this work is to simulate an accident of a 35% of fracture at the reactor's entrance collector with the FIREBIRD III code, Mod. 1.0, in order to compare the results obtained with those stated in the Safety Report, and besides, to verify the capacity to foresee the steam generator's secondary boundary behaviour on the basis of the actually available models. For this type of fractures, it is expected that this does not basically affect the Heat Transport Primary Loop behaviour since the main heat drain is the fracture. (Author)

  4. Fiber optic sensor based on Mach-Zehnder interferometer for securing entrance areas of buildings

    Science.gov (United States)

    Nedoma, Jan; Fajkus, Marcel; Martinek, Radek; Mec, Pavel; Novak, Martin; Bednarek, Lukas; Vasinek, Vladimir

    2017-10-01

    Authors of this article focused on the utilization of fiber optic sensors based on interferometric measurements for securing entrance areas of buildings such as windows and doors. We described the implementation of the fiber-optic interferometer (type Mach-Zehnder) into the window frame or door, sensor sensitivity, analysis of the background noise and methods of signal evaluation. The advantage of presented solution is the use of standard telecommunication fiber standard G.652.D, high sensitivity, immunity of sensor to electromagnetic interference (EMI) and passivity of the sensor regarding power supply. Authors implemented the Graphical User Interface (GUI) which offers the possibility of remote monitoring presented sensing solution.

  5. Digital radiography of scoliosis with a scanning method: radiation dose optimization

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, Haakan; Andersson, Torbjoern [Department of Radiology, Oerebro University Hospital, 701 85 Oerebro (Sweden); Verdonck, Bert [Philips Medical Systems, P.O. Box 10,000, 5680 Best (Netherlands); Beckman, Karl-Wilhelm; Persliden, Jan [Department of Medical Physics, Oerebro University Hospital, 701 85 Oerebro (Sweden)

    2003-03-01

    The aim of this study was optimization of the radiation dose-image quality relationship for a digital scanning method of scoliosis radiography. The examination is performed as a digital multi-image translation scan that is reconstructed to a single image in a workstation. Entrance dose was recorded with thermoluminescent dosimeters placed dorsally on an Alderson phantom. At the same time, kerma area product (KAP) values were recorded. A Monte Carlo calculation of effective dose was also made. Image quality was evaluated with a contrast-detail phantom and Visual Grading. The radiation dose was reduced by lowering the image intensifier entrance dose request, adjusting pulse frequency and scan speed, and by raising tube voltage. The calculated effective dose was reduced from 0.15 to 0.05 mSv with reduction of KAP from 1.07 to 0.25 Gy cm{sup 2} and entrance dose from 0.90 to 0.21 mGy. The image quality was reduced with the Image Quality Figure going from 52 to 62 and a corresponding reduction in image quality as assessed with Visual Grading. The optimization resulted in a dose reduction to 31% of the original effective dose with an acceptable reduction in image quality considering the intended use of the images for angle measurements. (orig.)

  6. Characteristics of dosemeter types for skin dose measurements in practice

    International Nuclear Information System (INIS)

    Van, D. J.; Bosmans, H.; Marchal, G.; Wambersie, A.

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use. (authors)

  7. PCR múltiple para la detección de los genes sea, seb, sec, sed y see de Staphylococcus aureus: Caracterización de aislamientos de origen alimentario Multiplex PCR for the detection of sea, seb, sec, sed and see genes of Staphylococcus aureus: Characterization of isolates from food

    Directory of Open Access Journals (Sweden)

    E. A. Manfredi

    2010-09-01

    Full Text Available La presencia de Staphylococcus aureus en los alimentos representa un riesgo potencial para la salud pública; sus enterotoxinas son el principal factor de virulencia. La detección de las enterotoxinas de S. aureus puede realizarse por ELISA, aunque sólo es posible detectar el pool de enterotoxinas SEA, SEB, SEC, SED y SEE. Los objetivos del presente trabajo fueron optimizar dos técnicas de PCR múltiple para la detección de los genes sea, seb, sec, sed y see de S. aureus y caracterizar un conjunto de 115 aislamientos de Staphylococcus spp. asociados a intoxicaciones alimentarias provenientes de diferentes provincias de Argentina. La caracterización se realizó por pruebas bioquímicas, ELISA y PCR. Sesenta y ocho aislamientos (59,1% fueron positivos por ELISA, mientras que 61 (53% fueron positivos por PCR. De los aislamientos positivos por PCR, 34 (55,7% portaron el gen sea, 9 (14,8% el gen seb, 5 (8,1% el gen see, 4 (6,5% el gen sec, 6 (9,9% los genes sea y seb, 2 (3,3% los genes sea y sec, y 1 (1,7% los genes sea y sed. Este es el primer estudio de caracterización genotípica de aislamientos de S. aureus asociados con brotes de intoxicación alimentaria registrados en distintas provincias argentinas.The presence of Staphylococcus aureus in food represents a potential risk to public health, being its enterotoxins the major virulence factor. Enterotoxin detection can be determined by ELISA, but only for the pool of enterotoxins SEA, SEB, SEC, SED and SEE. The main aims of this study were to optimize two PCR techniques for detection of S. aureus sea, seb, sec, sed and see, and to characterize Staphylococcus spp. isolates associated with food intoxication. Two PCR techniques were optimized and 115 Staphylococcus spp. isolates from Ciudad Autónoma de Buenos Aires, and Buenos Aires, Córdoba, and Neuquén provinces were characterized. The characterization was performed by biochemical tests, ELISA and PCR. Sixty-eight isolates (59.1% were

  8. Eight new luminous z ≥ 6 quasars discovered via SED model fitting of VISTA, WISE and Dark Energy Survey Year 1 observations

    Science.gov (United States)

    Reed, S. L.; McMahon, R. G.; Martini, P.; Banerji, M.; Auger, M.; Hewett, P. C.; Koposov, S. E.; Gibbons, S. L. J.; Gonzalez-Solares, E.; Ostrovski, F.; Tie, S. S.; Abdalla, F. B.; Allam, S.; Benoit-Lévy, A.; Bertin, E.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; da Costa, L. N.; DePoy, D. L.; Desai, S.; Diehl, H. T.; Doel, P.; Evrard, A. E.; Finley, D. A.; Flaugher, B.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gaztanaga, E.; Goldstein, D. A.; Gruen, D.; Gruendl, R. A.; Gutierrez, G.; James, D. J.; Kuehn, K.; Kuropatkin, N.; Lahav, O.; Lima, M.; Maia, M. A. G.; Marshall, J. L.; Melchior, P.; Miller, C. J.; Miquel, R.; Nord, B.; Ogando, R.; Plazas, A. A.; Romer, A. K.; Sanchez, E.; Scarpine, V.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, R. C.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Tucker, D. L.; Walker, A. R.; Wester, W.

    2017-07-01

    We present the discovery and spectroscopic confirmation with the European Southern Observatory New Technology Telescope (NTT) and Gemini South telescopes of eight new, and the rediscovery of two previously known, 6.0 VISTA Hemisphere Survey (J, H, K) and Wide-field Infrared Survey Explorer (W1, W2). The photometric data were fitted with a grid of quasar model SEDs with redshift-dependent Ly α forest absorption and a range of intrinsic reddening as well as a series of low-mass cool star models. Candidates were ranked using an SED-model-based χ2-statistic, which is extendable to other future imaging surveys (e.g. LSST and Euclid). Our spectral confirmation success rate is 100 per cent without the need for follow-up photometric observations as used in other studies of this type. Combined with automatic removal of the main types of non-astrophysical contaminants, the method allows large data sets to be processed without human intervention and without being overrun by spurious false candidates. We also present a robust parametric redshift estimator that gives comparable accuracy to Mg II and CO-based redshift estimators. We find two z ˜ 6.2 quasars with H II near zone sizes ≤3 proper Mpc that could indicate that these quasars may be young with ages ≲ 106-107 years or lie in over dense regions of the IGM. The z = 6.5 quasar VDES J0224-4711 has JAB = 19.75 and is the second most luminous quasar known with z ≥ 6.5.

  9. Localized electron density enhancements in the high-altitude polar ionosphere and their relationships with storm-enhanced density (SED plumes and polar tongues of ionization (TOI

    Directory of Open Access Journals (Sweden)

    Y. Kitanoya

    2011-02-01

    Full Text Available Events of localized electron density increase in the high-altitude (>3000 km polar ionosphere are occasionally identified by the thermal plasma instruments on the Akebono satellite. In this paper, we investigate the vertical density structure in one of such events in detail using simultaneous observations by the Akebono and DMSP F15 satellites, the SuperDARN radars, and a network of ground Global Positioning System (GPS receivers, and the statistical characteristics of a large number (>10 000 of such events using Akebono data over half of an 11-year solar cycle. At Akebono altitude, the parallel drift velocity is remarkably low and the O+ ion composition ratio remarkably high, inside the high plasma-density regions at high altitude. Detailed comparisons between Akebono, DMSP ion velocity and density, and GPS total electron content (TEC data suggest that the localized plasma density increase observed at high altitude on Akebono was likely connected with the polar tongue of ionization (TOI and/or storm enhanced density (SED plume observed in the F-region ionosphere. Together with the SuperDARN plasma convection map these data suggest that the TOI/SED plume penetrated into the polar cap due to anti-sunward convection and the plume existed in the same convection channel as the dense plasma at high altitude; in other words, the two were probably connected to each other by the convecting magnetic field lines. The observed features are consistent with the observed high-density plasma being transported from the mid-latitude ionosphere or plasmasphere and unlikely a part of the polar wind population.

  10. The robustness in dynamics of out of equilibrium bidirectional transport systems with constrained entrances

    Science.gov (United States)

    Sharma, Natasha; Verma, Atul Kumar; Gupta, Arvind Kumar

    2018-05-01

    Macroscopic and microscopic long-distance bidirectional transfer depends on connections between entrances and exits of various transport mediums. Persuaded by the associations, we introduce a small system module of Totally Asymmetric Simple Exclusion Process including oppositely directed species of particles moving on two parallel channels with constrained entrances. The dynamical rules which characterize the system obey symmetry between the two species and are identical for both the channels. The model displays a rich steady-state behavior, including symmetry breaking phenomenon. The phase diagram is analyzed theoretically within the mean-field approximation and substantiated with Monte Carlo simulations. Relevant mean-field calculations are also presented. We further compared the phase segregation with those observed in previous works, and it is examined that the structure of phase separation in proposed model is distinguished from earlier ones. Interestingly, for phases with broken symmetry, symmetry with respect to channels has been observed as the distinct particles behave differently while the similar type of particles exhibits the same conduct in the system. For symmetric phases, significant properties including currents and densities in the channels are identical for both types of particles. The effect of symmetry breaking occurrence on the Monte Carlo simulation results has also been examined based on particle density histograms. Finally, phase properties of the system having strong size dependency have been explored based on simulations findings.

  11. Using Mathematical Modeling Methods for Estimating Entrance Flow Heterogeneity Impact on Aviation GTE Parameters and Performances

    Directory of Open Access Journals (Sweden)

    Yu. A. Ezrokhi

    2017-01-01

    Full Text Available The paper considers methodological approaches to the mathematical models (MM of various levels, dedicated to estimate an impact of the entrance flow heterogeneity on the main parameters and performances of the aviation GTE and it units. By an example of calculation of a twin-shaft turbofan engine in cruiser mode, demonstrates engineering mathematical model capabilities to define the impact of the total pressure field distortion on engine trust and air flow parameters, and also gas dynamic stability margin of the both compressors.It is shown that the presented first level mathematical model allows us to estimate sufficiently the impact of entrance total pressure heterogeneity on the engine parameters. Here reliability of calculations is proved to be true by their comparison with the results, obtained owing to well fulfilled 2D & 3D mathematical models of the engine, which have been repeatedly identified by the results of experiments.It is shown that received results including those on decreasing values of stability margin of both compressors can be used for tentative estimates when choosing a desirable stability margin, providing steady operation of compressors and engine in an entire range of its operating modes. Carrying out a definitive testing calculation using the specialized engine MM of a higher level will not only confirm the results obtained, but also reduce their expected error with regard to the real values reached as a result of tests.

  12. In Rio de Janeiro public entrance areas disappeared behind railings out of fear of crime

    Directory of Open Access Journals (Sweden)

    Katja Friedrich

    2013-05-01

    Full Text Available The need for safety leads to an increasing fencing of entrance areas and to a structural spatial segregation in Rio de Janeiro. Today’s passerby moves along high grids instead of walking on lavishly planted ways along noble entrance areas. In the scale of urban development the stronger variant of spatial demarcation is taking place. Gated communities arise as a total spatial exclusion, in a safe distance to existing favelas and disposing of abundant safety equipment.Precisely because the need for safety is important in dwelling, both trends are problematic from the urban perspective. The increasing fencing and demarcating destroys pleasant urban atmospheres and fosters the spreading of mono-functional resp. mono-social areas. However, trust and a peaceful togetherness are required for a socially and functionally mixed and spatially diversified public space. But these conditions can only be realised in the context of the entire society.

  13. WASHBACK OF THE ENGLISH SECTION OF COLLEGE ENTRANCE EXAM ON THE STUDENTS’ PRODUCTIVE AND RECEPTIVE SKILLS

    Directory of Open Access Journals (Sweden)

    Fitri Wulandari Wulandari

    2016-09-01

    Full Text Available Exam plays a powerful role in educational system and exerts significant washback onstudents’ learning. Washback, the impact of exams on education in general andlanguage examining in particular, has become a popular area of study withineducational research. This paper focuses on the washback effects of college entranceexam on students’ productive and receptive skills in STKIP MuhammadiyahPringsewu Lampung. The main concern of the study was to investigate the impact ofcollege entrance exam on productive and receptive language skills in STKIPMuhammadiyah Pringsewu Lampung. 53 first year students at English EducationDepartment in the academic year of 2015-2016 of STKIP Muhammadiyah PringsewuLampung attended the study. A 26-item questionnaire was designed and administeredto 53 students. The data were analyzed using statistical analysis including descriptivestatistics (frequency, percentage, mean, and standard deviation. It has been found outthat the exam has some negative effects on students’ language productive andreceptive skills on the first year students at English Education Department of STKIPMuhammadiyah Pringsewu Lampung. Some changes to exam that might be gratefulare discussed in the last section of the paper.Keywords: washback effect, college entrance exam, students’ productive skills

  14. Evaluation of the image quality criteria and study of doses in a mammography department

    International Nuclear Information System (INIS)

    Alcantara, Marcela Costa

    2009-01-01

    The mammographic image quality criteria published by European Commission were implemented in three mammography equipment of a same radiology department in a hospital of Sao Paulo city. Among the mammography equipment, two use the screen-film system and one of them uses the indirect digital system. During the data collection, it was noted the need to conduct a study about image rejection in each mammography equipment. Therefore, this study was realized and, after that, the results in each mammography equipment of image rejection and image percentage that present each quality criterion it were compared. At the same time of this studies, it was realized other study about surface entrance dose and average glandular dose. These doses it was estimated based on different methods published by different groups of researcher, for all combinations anode filter available in the equipment. To estimate the surface entrance dose following the methodology published in Avenue's' guide and the average glandular dose following the Wu' methodology, it was developed a phantom, in different thicknesses of acrylic, to simulate a breast. Finally, the image quality it was associated with the dose received by patient. The digital equipment shows better results in the evaluation of quality criteria, lower rate of image rejection and lower values of average glandular dose and surface entrance dose in all methods studied. But it is not sufficient, because is not adequate for patients with great breast. (author)

  15. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  16. Anatomical relation between S1 sacroiliac screws' entrance points and superior gluteal artery.

    Science.gov (United States)

    Zhao, Yong; You, Libo; Lian, Wei; Zou, Dexin; Dong, Shengjie; Sun, Tao; Zhang, Shudong; Wang, Dan; Li, Jingning; Li, Wenliang; Zhao, Yuchi

    2018-01-18

    To conduct radiologic anatomical study on the relation between S1 sacroiliac screws' entry points and the route of the pelvic outer superior gluteal artery branches with the aim to provide the anatomical basis and technical reference for the avoidance of damage to the superior gluteal artery during the horizontal sacroiliac screw placement. Superior gluteal artery CTA (CT angiography) vascular imaging of 74 healthy adults (37 women and 37 men) was done with 128-slice spiral CT (computed tomography). The CT attendant-measuring software was used to portray the "safe bony entrance area" (hereinafter referred to as "Safe Area") of the S1 segment in the standard lateral pelvic view of three-dimensional reconstruction. The anatomical relation between S1 sacroiliac screws' Safe Area and the pelvic outer superior gluteal artery branches was observed and recorded. The number of cases in which artery branches intersected the Safe Area was counted. The cases in which superior gluteal artery branches disjointed from the Safe Area were identified, and the shortest distance between the Safe Area and the superior gluteal artery branch closest to the Safe Area was measured. Three cases out of the 74 sample cases were excluded from this study as they were found to have no bony space for horizontal screw placement in S1 segment. Among the remaining 71 sample cases, there are 32 cases (45.1%) where the deep superior branch of superior gluteal artery passes through the Safe Area of S1 entrance point. There was no distinguishing feature and rule on how the deep superior branches and the Safe Area overlapped. In the 39 cases in which superior gluteal artery branches disjointed from the Safe Area, the deep superior branches of superior gluteal artery were the branches closest to the Safe Area and the part of the branch closest to the Safe Area was located in front of the widest part of the Safe Area. The shortest distance between the deep superior branch and the Safe Area is 0.86

  17. Disproportionate entrance length in superfluid flows and the puzzle of counterflow instabilities

    Science.gov (United States)

    Bertolaccini, J.; Lévêque, E.; Roche, P.-E.

    2017-12-01

    Systematic simulations of the two-fluid model of superfluid helium (He-II) encompassing the Hall-Vinen-Bekharevich-Khalatnikov (HVBK) mutual coupling have been performed in two-dimensional pipe counterflows between 1.3 and 1.96 K. The numerical scheme relies on the lattice Boltzmann method. A Boussinesq-like hypothesis is introduced to omit temperature variations along the pipe. In return, the thermomechanical forcings of the normal and superfuid components are fueled by a pressure term related to their mass-density variations under an approximation of weak compressibility. This modeling framework reproduces the essential features of a thermally driven counterflow. A generalized definition of the entrance length is introduced to suitably compare entry effects (of different nature) at opposite ends of the pipe. This definition is related to the excess of pressure loss with respect to the developed Poiseuille-flow solution. At the heated end of the pipe, it is found that the entrance length for the normal fluid follows a classical law and increases linearly with the Reynolds number. At the cooled end, the entrance length for the superfluid is enhanced as compared to the normal fluid by up to one order of magnitude. At this end, the normal fluid flows into the cooling bath of He-II and produces large-scale superfluid vortical motions in the bath that partly re-enter the pipe along its sidewalls before being damped by mutual friction. In the superfluid entry region, the resulting frictional coupling in the superfluid boundary layer distorts the velocity profiles toward tail flattening for the normal fluid and tail raising for the superfluid. Eventually, a simple analytical model of entry effects allows us to re-examine the long-debated thresholds of T 1 and T 2 instabilities in superfluid counterflows. Inconsistencies in the T 1 thresholds reported since the 1960s disappear if an aspect-ratio criterion based on our modeling is used to discard data sets with the

  18. Determination of doses and cancer risk to patients undergoing digital x-ray examinations at the Tamale Teaching Hospital

    International Nuclear Information System (INIS)

    Aweligiba, S.A.

    2015-07-01

    Entrance surface and effective doses as well as cancer risk to patients for three common radiological examinations were estimated at the radiology department of the Tamale Teaching Hospital. The quality control assessment indicated that the digital x-ray equipment used, performed self-consistently in line with acceptable performance criteria. The study included eighty-two (82) adult patients undergoing three x-ray imaging modalities; Chest, Abdomen and Pelvis Examinations. From the study the mean entrance dose to abdomen and pelvis were found to be 0.6 ± 0.2 mGy whiles that of chest was found to be 0.2 ± 0.1 mGy. These were found to be lower than results of studies carried out elsewhere. The effective dose to patient was computed using PCXMC 2.0 software. The results shows an average effective dose of 0.036 mSv, 0.084 mSv and 0.067 mSv for chest, abdomen and pelvis examinations respectively. The risk of radiation induced cancer as a result to entrance surface dose was found to be 5.68 x 10-5 %, 1.58 x 10-4 % and 1.49 x 10-4 % for Chest, Abdomen and Pelvis examinations respectively. The third quartile values of the entrance surface dose were found to be lower than recommended diagnostic reference levels published by NRPB, UK and the IAEA for the examinations under study. (author)

  19. Nordic Guidance Levels for Patient Doses in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Saxebol, G.; Olerud, H.M.; Hjardemaal, O.; Leitz, W.; Servomaa, A.; Walderhaug, T.

    1998-01-01

    Within the framework of Nordic authoritative cooperation in radiation protection and nuclear safety, recommendations have been prepared dealing with dose constraints in diagnostic radiology. A working group with participants from all the Nordic countries has met and discussed possible implementations of the ICRP dose constraint for medical radiology. Dose constraints, expressed as guidance levels, were specified for six different radiological examinations, i.e. chest, pelvis, lumbar spine, urography, barium meal and enema in units of kerma-area product and entrance surface dose. The recommendations are described in report No 5 in the series 'Report on Nordic Radiation Protection Cooperation'. Examples of dose distributions and factors affecting the patient dose are described in the report. (author)

  20. Evaluation of Patient Radiation Dose during Orthopedic Surgery

    International Nuclear Information System (INIS)

    Osman, H; Elzaki, A.; Sam, A.K.; Sulieman, A.

    2013-01-01

    The number of orthopedic procedures requiring the use of the fluoroscopic guidance has increased over the recent years. Consequently the patient exposed to un avoidable radiation doses. The aim of the current study was to evaluate patient radiation dose during these procedures.37 patients under went dynamic hip screw (DHS) and dynamic cannulated screw (DCS) were evaluated using calibrated Thermolumincent Dosimeters (TLDs), under carm fluoroscopic machines ,in three centers in Khartoum-Sudan. The mean Entrance Skin Dose (ESD) was 7.9 m Gy per procedure. The bone marrow and gonad organ exposed to significant doses. No correlation was found between ESD and Body Mass Index (BMI), or patient weight. Well correlation was found between kilo voltage applied and ESD. Orthopedic surgeries delivered lower radiation dose to patients than cardiac catheterization or hysterosalpingraphy (HSG) procedures. More study should be implemented to follow radiation dose before surgery and after surgery

  1. The precision of radiotherapy in Gliwice, Poland, estimated by in vivo dose measurements

    International Nuclear Information System (INIS)

    Orlef, A.; Lobodziec, W.; Maniakowski, Z.

    1995-01-01

    The aim of this work was to evaluate the precision of irradiation using gamma Co-60 Philips Unites and linear accelerators Neptun 10p and Saturne II+ which generate X-rays of 9MV and 23MV respectively. This work has been undertaken for the reason that the effect of radiotherapy of cancer is strongly dependent of the precision of the dose delivery to a patient. The in vivo dose measurements were performed using a p-type silicon diodes (EDE-5, EDP-20, EDP-30) connected to a DPD-510 electrometer (Scanditronix). The diodes were calibrated by comparison their response to a 0.6cm 3 ionization chamber (NE 2571) placed at the relevant depth in the phantom. The entrance and exit dose calibration factors have been determined for reference conditions (constant SSD, field, temperature, ...). For conditions different from reference one the correction factors have been evaluated. The 855 in vivo dose measurements of entrance dose were performed. The histograms of percentage differences between measured and planed entrance dose has been constructed and analyzed. The average values of such differences were: -1.3%, 4.0%, -0.9% for gamma Co-60, X 9MV, X 23MV, respectively. These values can be interpreted as systematic uncertainties. The standard deviations (SD) were found as: 3.1%, 4.1%, 3.5%. These parameters can be considered as a random uncertainties. The 546 cases of dose at the reference point for head and neck cancer have been evaluated taking into account the entrance and exit measured doses. The average difference between those values and planned one was 1.3% and SD = 5.1%. There were observed the changes of the dimensions of the irradiated tissue block during the radiotherapy. This had a significant influence on the differences between delivered (measured) and planed doses at reference point

  2. Effects of entrance configuration on pressure loss and heat transfer of transitional gas flow in a circular tube

    International Nuclear Information System (INIS)

    Ogawa, Masuro; Kawamura, Hiroshi

    1986-01-01

    Pressure loss and heat transfer of a transitional gas flow are affected significantly by the entrance configuration. The friction factor and the heat transfer coefficient were measured using a circular tube with four different kinds of entrance configurations. The Reynolds number at the transition from laminar to intermittent flow was varied from about 1,940 to 9,120. The intermittency factor was measured for heated and unheated flows ; and the relation between the intermittency and the friction factor or heat transfer coefficient was examined. Several existing correlations were tested and found to correlate with the experimental results fairly well. (author)

  3. [Evaluation of music department students who passed the entrance exam with phonetogram (Voice Range Profile)].

    Science.gov (United States)

    Gökdoğan, Çağıl; Gökdoğan, Ozan; Şahin, Esra; Yılmaz, Metin

    2014-01-01

    This study aims to evaluate phonetogram data of the students in the department of music who passed the entrance exam. The phonetogram data of 44 individuals with a good voice quality in the department of music and age-matched individuals who were not trained in the field of music or not involved in music amateurish as the control group were compared. The voice of both groups were recorded using the voice range profile within the scope of Kay Elemetrics CSL (Model 4300 B) programmed. There was a significant difference in the voice range profile parameters including max Fo, Fo range, Fo range (St), min dB SPL, and max dB sound pressure level (pmusic is higher than the control group and that plays a major role in their acceptance to the department of music.

  4. Washback Effect of University Entrance exams in Applied Mathematics to Social Sciences.

    Science.gov (United States)

    Rodríguez-Muñiz, Luis J; Díaz, Patricia; Mier, Verónica; Alonso, Pedro

    2016-01-01

    Curricular issues of subject Applied Mathematics to Social Sciences are studied in relation to university entrance exams performed in several Spanish regions between 2009-2014. By using quantitative and qualitative analyses, it has been studied how these exams align with curriculum and how they produce a washback on curriculum and teachers' work. Additionally, one questionnaire about teachers' practices has been performed, in order to find out how the exams are influencing teaching methodology development. Main results obtained show that evaluation is producing a bias on the official curriculum, substantially simplifying the specific orientation that should guide applied mathematics. Furthermore, teachers' practices are influenced by the exams, and they usually approach their teaching methodology to the frequent types of exams. Also, slight differences among the teachers lead to distinguish two behavioral subgroups. Results can also be useful in an international context, because of the importance of standardized exit exams in OECD countries.

  5. Images of the laser entrance hole from the static x-ray imager at NIF.

    Science.gov (United States)

    Schneider, M B; Jones, O S; Meezan, N B; Milovich, J L; Town, R P; Alvarez, S S; Beeler, R G; Bradley, D K; Celeste, J R; Dixit, S N; Edwards, M J; Haugh, M J; Kalantar, D H; Kline, J L; Kyrala, G A; Landen, O L; MacGowan, B J; Michel, P; Moody, J D; Oberhelman, S K; Piston, K W; Pivovaroff, M J; Suter, L J; Teruya, A T; Thomas, C A; Vernon, S P; Warrick, A L; Widmann, K; Wood, R D; Young, B K

    2010-10-01

    The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 μm spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

  6. Washback Effect of University Entrance exams in Applied Mathematics to Social Sciences

    Science.gov (United States)

    Díaz, Patricia; Mier, Verónica; Alonso, Pedro

    2016-01-01

    Curricular issues of subject Applied Mathematics to Social Sciences are studied in relation to university entrance exams performed in several Spanish regions between 2009–2014. By using quantitative and qualitative analyses, it has been studied how these exams align with curriculum and how they produce a washback on curriculum and teachers’ work. Additionally, one questionnaire about teachers’ practices has been performed, in order to find out how the exams are influencing teaching methodology development. Main results obtained show that evaluation is producing a bias on the official curriculum, substantially simplifying the specific orientation that should guide applied mathematics. Furthermore, teachers’ practices are influenced by the exams, and they usually approach their teaching methodology to the frequent types of exams. Also, slight differences among the teachers lead to distinguish two behavioral subgroups. Results can also be useful in an international context, because of the importance of standardized exit exams in OECD countries. PMID:27936103

  7. Entrance channel effects and the superdeformed band in {sup 152}Dy

    Energy Technology Data Exchange (ETDEWEB)

    Beausang, C W; Alderson, A; Ali, I; Dagnall, P J; Fallon, P; Forsyth, P D; Smith, G; Twin, P J [Liverpool Univ. (United Kingdom); France, G de; Duchene, G; Flibotte, S; Haas, B; Romain, P; Theisen, C H; Vivien, J P [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Bentley, M A [Daresbury Lab. (United Kingdom)

    1992-08-01

    Recent experiments on {sup 152}Dy indicate that the fraction of decays via the superdeformed (SD) band depends on the mass asymmetry in the entrance channel. Such results may indicate that the time scale for fusion is larger for mass symmetric reactions than for mass asymmetric ones, thus allowing neutron evaporation to compete better with fusion. To test this idea, one needs accurate intensity measurements of the highest member of the SD band, using a very large data set, so it is an ideal experiment for the Eurogam array. At the time of the conference, a series of experiments was being carried out using the {sup 36}S + {sup 120}Sn and {sup 82}Se + {sup 74}Ge reactions. Preliminary results were inconclusive. 7 refs., 3 figs.

  8. Ventilation of multi-entranced rodent burrows by boundary layer eddies.

    Science.gov (United States)

    Brickner-Braun, Inbal; Zucker-Milwerger, Daniel; Braun, Avi; Turner, J Scott; Pinshow, Berry; Berliner, Pedro

    2014-12-01

    Rodent burrows are often assumed to be environments wherein the air has a high concentration of CO₂. Although high burrow [CO₂] has been recorded, many studies report burrow [CO₂] that differs only slightly from atmospheric concentrations. Here, we advocate that one of the reasons for these differences is the penetration into burrows of air gusts (eddies), which originate in the turbulent boundary layer and prevent build-up of CO₂. We have characterized the means by which burrows of Sundevall's jird, which are representative of the burrows of many rodent species with more than one entrance, are ventilated. Our results demonstrate that, even at low wind speeds, the random penetration of eddies into a burrow through its openings is sufficient to keep the burrow [CO₂] low enough to be physiologically inconsequential, even in its deep and remote parts. © 2014. Published by The Company of Biologists Ltd.

  9. The influence of the entrance channel mass asymmetry on the reaction mechanism

    International Nuclear Information System (INIS)

    Agarwal, S.; Galin, J.; Gatty, B.; Guerreau, D.; Lefort, M.; Tarrago, X.; Babinet, R.; Girard, J.

    1980-01-01

    We have tried to investigate the influence of the entrance channel mass asymmetry on the reaction mechanisms associated with heavy ion collisions. Two systems, one very much asymmetric (O + Mo) and the other one almost symmetric (Cr + Fe), were studied in detail by measuring evaporation residues, deep inelastic collision products and fission fragments. An important fraction of the fragments observed in the Cr + Fe system exhibits all the characteristics of fission fragments. The analysis of these data seems to indicate that these fission like products are most likely emitted by a long lived composite system having not reached full statistical equilibrium for all the degrees of freedom. As a consequence, the fusion cross section for this symmetric system is too low as compared to predictions based on a critical distance approach for fusion, whereas the asymmetric system (O + Mo) is well understood in terms of the same model. (orig.)

  10. Conversion coefficients for determining organ doses in paediatric pelvis and hip joint radiography

    International Nuclear Information System (INIS)

    Seidenbusch, Michael C.; Schneider, Karl

    2014-01-01

    Knowledge of organ and effective doses achieved during paediatric X-ray examinations is an important prerequisite for assessment of radiation burden to the patient. Conversion coefficients for reconstruction of organ and effective doses from entrance doses for pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional pelvis and hip joint radiographs were calculated by performing Monte Carlo simulations in mathematical hermaphrodite phantom models representing patients of different ages. The clinical variation of radiation field settings was taken into consideration by defining optimal and suboptimal standard field settings. Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal beam projection and the standard focus detector distance of 115 cm. The conversion coefficients presented can be used for organ dose assessments from entrance doses measured during pelvis and hip joint radiographs of children and young adults with all field settings within the optimal and suboptimal standard field settings. (orig.)

  11. Sensitivity of low-energy incomplete fusion to various entrance-channel parameters

    Science.gov (United States)

    Kumar, Harish; Tali, Suhail A.; Afzal Ansari, M.; Singh, D.; Ali, Rahbar; Kumar, Kamal; Sathik, N. P. M.; Ali, Asif; Parashari, Siddharth; Dubey, R.; Bala, Indu; Kumar, R.; Singh, R. P.; Muralithar, S.

    2018-03-01

    The disentangling of incomplete fusion dependence on various entrance channel parameters has been made from the forward recoil range distribution measurement for the 12C+175Lu system at ≈ 88 MeV energy. It gives the direct measure of full and/or partial linear momentum transfer from the projectile to the target nucleus. The comparison of observed recoil ranges with theoretical ranges calculated using the code SRIM infers the production of evaporation residues via complete and/or incomplete fusion process. Present results show that incomplete fusion process contributes significantly in the production of α xn and 2α xn emission channels. The deduced incomplete fusion probability (F_{ICF}) is compared with that obtained for systems available in the literature. An interesting behavior of F_{ICF} with ZP ZT is observed in the reinvestigation of incomplete fusion dependency with the Coulomb factor (ZPZT), contrary to the recent observations. The present results based on (ZPZT) are found in good agreement with recent observations of our group. A larger F_{ICF} value for 12C induced reactions is found than that for 13C, although both have the same ZPZT. A nonsystematic behavior of the incomplete fusion process with the target deformation parameter (β2) is observed, which is further correlated with a new parameter (ZP ZT . β2). The projectile α -Q-value is found to explain more clearly the discrepancy observed in incomplete fusion dependency with parameters ( ZPZT) and (ZP ZT . β2). It may be pointed out that any single entrance channel parameter (mass-asymmetry or (ZPZT) or β2 or projectile α-Q-value) may not be able to explain completely the incomplete fusion process.

  12. Biletul de intrare şi marketingul muzeal / Entrance ticket and museum marketing

    Directory of Open Access Journals (Sweden)

    Elena Ploşniţa

    2015-10-01

    Full Text Available Today the museum as an institution serving society is recognized as one of the largest educational and cultural resources, open to the public and having a huge impact on people. But nowadays the museum is also perceived as the market of cultural values. The activities of the modern museums are increasingly measured by economic criteria: profitability, efficiency, number of visitors, the cost of a visit, demand, cultural product, etc. And this happens not only in USA or Western Europe, but throughout the world, including the Republic of Moldova. In order to survive in the society of market economy, museums use marketing strategy, and marketing is increasingly seen as a very useful tool for the successful execution of their duties in the public interest. The purpose of marketing is to attract visitors by finding the best ways to meet their needs and desires. Since the entrance to most museums is paid, the author of this article examines the marketing function of a museum ticket as a museum product. For analysis several tickets of the museums of the Republic of Moldova, as well as from a number of European countries were taken. The objectives of the museum ticket are the same everywhere: little information for visitors, promotion of the museum, the museum advertising, and so on. Its development is a complex process that must be monitored and evaluated step by step. In fact, the ticket is a document of strict accountability, containing several mandatory attributes such as name, logo of the museum, contact information, and so on. As a result of the analysis, the author concludes that the ticket can do a lot of marketing functions: to promote the museum, to inform visitors, to promote public relations, act as a souvenir. One of the main functions of an entrance ticket is communication.

  13. Variability of the vertebral artery origin and transverse foramen entrance level - CT angiographic study.

    Science.gov (United States)

    Vujmilović, Siniša; Spasojević, Goran; Vujnović, Saša; Malobabić, Slobodan; Vujković, Zoran

    2018-04-13

    Vertebral artery (VA), the main element of the posterior brain circulation, has many anatomical variations which generally were widely investigated. However, available data vary in wide ranges, reflecting very different sample sizes, lack of data about left-right or sex differences, and about possible ethnic, regionally specific or genetic differences. Certain new findings suggest possible involvement of some environmental factors in VA variations. Accurate anatomical data about VA variations in different regions of the world, including Balkans countries, are still lacking. Therefore we investigated morphological variability of VA origin and its entrance level into cervical transverse foramina in population of Republika Srpska (Bosnia and Herzegovina), including data about the sex and side. Anatomy of VA was investigated in 112 persons (224 arteries) of both sexes (58 males, 54 females; age 19 - 83 years), using 64-slice CT scanner. Origin of VA from subclavian artery (SCA) we found in 95.08% of arteries (52 males, 49 females). Only in one male (0.45 %) left VA and left SCA had an specific origin from aortic arch (AA), which we named as an "common area of origin". All other observed variations in origin were only of left VA, originating from AA in 4.47 % (5 males, 5 females). Left VA Most often (usual) entrance level into transverse foramen we found at C6 (87.5%), followed by C5 (8.93 %), C4 (3.12 %), and in one case at level C7 (0.45 %). Entry levels at C5 both, on right and on the left side, were 3 times more frequent in males than in females. Wide ranges of differences between the data we obtained on a sample in Republika Srpska (Bosnia and Herzegovina) and the data from many other studies require further and wider investigations.

  14. Pentobarbital anesthesia and the response of tumor and normal tissue in the C3Hf/SED mouse to radiation

    International Nuclear Information System (INIS)

    Suit, H.D.; Sedlacek, R.S.; Silver, G.; Dosoretz, D.

    1985-01-01

    Experiments have been performed to assess the effect of sodium pentobarbital (NaPb) on the response of MCaIV, FSaII, and SCCVII using TCD50 and acute reaction of normal skin as end points. The TCD50 was lower or unchanged in the anesthetized than in the conscious mouse. There was no effect of NaPb on the acute reaction of skin. The ERs for NaPb on the TCD50 (ν = 1) for air breathing condition was essentially 1.0 for all three tumors. For the FSaII and SCCVII pentobarbital enhancement ratios were 1.29 and 1.34 for O/sub 2/3ATA conditions. For two dose (ν=2) irradiations ERs for the O/sub 2/3ATA were 1.46, 1.72 and 2.21 for MCaIV, FSaII and SCCVII respectively. For ν = 15, temperature 35 0 C ERs for O/sub 2/3ATA were 1.08 and 1.09 for MCaIV and FSaII but 1.22 for SCCVII

  15. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  16. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  17. Patient doses in digital cardiac imaging

    International Nuclear Information System (INIS)

    Huda, W.; Ogden, K.M.; Roskopf, M.L.; Phadke, K.

    2001-01-01

    In this pilot study, we obtained estimates of entrance skin doses and the corresponding effective doses to patients undergoing digital cardiac imaging procedures on a GE Advantx LC/LP Plus system. Data were obtained for six patients undergoing diagnostic examinations and six patients who had interventional procedures. For each patient examination, radiographic techniques for fluoroscopic and digital cine imaging were recorded, together with the irradiation geometry. The projection with the highest exposure resulted in an average skin dose of 0.64 ± 0.41 Gy (maximum of 1.6 Gy). The average patient skin doses taking into account overlapping projections was 1.1 ± 0.8 Gy (maximum of 3.0 Gy). The exposure area product (EAP) incident on the patient was converted into the energy imparted to the patient and the corresponding effective dose. The average patient effective dose was 28 ± 14 mSv (maximum 62 mSv), with the resultant average fatal cancer risk estimated to be of the order of 8x10 -3 . Average doses for interventional procedures in cardiac imaging are higher than those associated with diagnostic examinations by approximately 50%. (author)

  18. Dose limits

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1987-12-01

    The dose limit is defined to be the level of harmfulness which must not be exceeded, so that an activity can be exercised in a regular manner without running a risk unacceptable to man and the society. The paper examines the effects of radiation categorised into stochastic and non-stochastic. Dose limits for workers and the public are discussed

  19. Impact of hip prosthesis on dose distribution of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Ren Jiangping; Zhang Songfang; Zhu Qibao; Guo Jianxin; Zha Yuanzi

    2011-01-01

    Objective: To study the scattering effect of Co-Cr-Mo hip prosthesis which was high Z material for patients undergoing pelvic irradiation. Methods: The hip prosthesis was set in water phantom (30 cm x 30 cm x 30 cm), determining points were chosen on the entrance side of both 6 MV and 10 MV beams at the distance of 0.5 cm, 1.0 cm, 2.0 cm to the hip prosthesis, and also on the exit side of both 6 MV and 10 MV beams at the distance of 3.0 cm, 5.0 cm, 7.0 cm to the hip prostheses. Dose behind the hip prosthesis at depths of 5.0 cm and 10.0 cm for 6 MV and 10 MV beams are also measured. Results: The dose deviation on the beams' entrance side is between 0 to 5.0%, the backscatter effect was more obviously with the higher energy beam. The dose deviation on the beams' exit side was between 21.6%-30.8%. With the same field size and depth, dose deviation becomes smaller when the beam energy was higher; while with the same energy and depth, dose deviation becomes smaller when the field size was bigger. Dose profiles behind the head of the hip prosthesis indicate obvious attenuation of the beam. Conclusions: Beam arrangements that avoid the prosthesis should be considered first or we should at least reduce the weight of the beam that pass through the prosthesis. (authors)

  20. Adult and child doses in standardised X ray examinations

    International Nuclear Information System (INIS)

    Gallini, R.E.; Belletti, S.; Berna, V.; Giugni, U.

    1992-01-01

    Data are presented on patient doses measured during standard hospital routine in seven radiological departments in the Province of Brescia. This study is part of a Quality Assurance Programme, carried out to assess the possibility and validity of a regional protocol. Before collecting dose data, tests on the performance of the X ray units and processors were performed in every department according to a Quality Control Protocol. The following examinations were considered: chest, knee, lumbar spine, pelvis, skull and barium meal. The surface entrance doses of 314 adults and 216 children were measured. The sample size for barium meal was lower: 65 adults and only 10 children. The patients anthropometric data and the technical parameters used were collected at the same time. For adults the organ doses and effective dose equivalent (EDE) were calculated. A wide range of entrance doses were obtained both for adults and children. The reasons can be: patient size, performance of the equipment and processors, film-screen combination, use of AEC, use of fluoroscopy and grid, training and skill of the staff

  1. Adult and child doses in standardised X ray examinations

    International Nuclear Information System (INIS)

    Gallini, R.E.; Belletti, S.; Berna, V.; Giugni, U.

    1992-01-01

    Data are presented on patient doses measured during standard hospital routine in seven radiological departments in the Province of Brescia, as part of a Quality Assurance Programme, carried out to assess the possibility and validity of a regional protocol. Before collecting dose data, tests on the performance of the X ray units and processors were performed in every department according to a Quality Control Protocol. The following examinations were considered: chest, knee, lumbar spine, pelvis, skull and barium meal. Surface entrance doses of 314 adults and 216 children were measured. The sample size for barium meal was lower: 65 adults and 10 children. The patients anthropometric data and technical parameters used were collected at the same time. For adults the organ doses and effective dose equivalent (EDE) were calculated. A wide range of entrance doses were obtained both for adults and children, due to patient size, performance of the equipment and processors, film-screen combination, use of AEC, use of fluoroscopy and grid, training and skill of the staff. (author)

  2. 33 CFR 165.1195 - Regulated Navigation Area; Humboldt Bay Bar Channel and Humboldt Bay Entrance Channel, Humboldt...

    Science.gov (United States)

    2010-07-01

    ... Entrance Channel, Humboldt Bay, California. (b) Definitions. As used in this section— COTP means the... person in charge of a vessel to which this notice applies shall obtain permission to cross within four... place during daylight hours, the vessel has only a single tow or no tow, the visibility at the bar is...

  3. Identifying Challenges and Opportunities for Residents in Upernavik as Oil Companies are Making a First Entrance into Baffin Bay

    DEFF Research Database (Denmark)

    Merrild, Anne; Tejsner, Pelle

    2016-01-01

    The oil industry is making its first entrance offshore in Baffin Bay in a time where Inuit residents on the northwest coast of Greenland are struggling to uphold a traditional way of living. The operating oil companies are encouraged by the Government of Greenland to promote a high degree of loca...

  4. Gender Gap in the National College Entrance Exam Performance in China: A Case Study of a Typical Chinese Municipality

    Science.gov (United States)

    Zhang, Yu; Tsang, Mun

    2015-01-01

    This is one of the first studies to investigate gender achievement gap in the National College Entrance Exam in a typical municipality in China, which is the crucial examination for the transition from high school to higher education in that country. Using ordinary least square model and quantile regression model, the study consistently finds that…

  5. A Time to Every Purpose: Understanding and Improving the Borrower Experience with Online Student Loan Entrance Counseling. Research Report

    Science.gov (United States)

    Fernandez, Chris

    2015-01-01

    Legally mandated student loan entrance counseling attempts to prepare first-time borrowers of federal student loans for this challenge; yet, researchers hypothesized that the online modules most borrowers use for this purpose have significant shortcomings. This report (the third in a series of five from TG Research) describes a study in which…

  6. Differential Predictive Validity of High School GPA and College Entrance Test Scores for University Students in Yemen

    Science.gov (United States)

    Al-Hattami, Abdulghani Ali Dawod

    2012-01-01

    High school grade point average and college entrance test scores are two admission criteria that are currently used by most colleges in Yemen to select their prospective students. Given their widespread use, it is important to investigate their predictive validity to ensure the accuracy of the admission decisions in these institutions. This study…

  7. Comparison of experimental hut entrance and exit behavior between Anopheles darlingi from the Cayo District, Belize, and Zungarococha, Peru.

    Science.gov (United States)

    Sachs, Paige; Diaz Rodriguez, Gloria Alicia; Briceno, Ireneo; King, Russell; Achee, Nicole L; Grieco, John P

    2013-12-01

    Anopheles darlingi is a major vector for malaria in Central and South America. Behavioral, ecological, genetic, and morphologic variability has been observed across its wide distribution. Recent studies have documented that 2 distinct genotypes exist for An. darlingi: a northern lineage (Belize, Guatemala, Colombia, Venezuela, and Panama) and a southern lineage (Amazonia and southern Brazil). In order to determine if these genotypes exhibited different behavioral traits, entrance and exit movement patterns between 2 field populations of An. darlingi that represented each genotype were evaluated using experimental huts. The Belize population exhibited bimodal entrance, with peak entry occurring between 7:00-8:00 p.m. and 5:00-6:00 a.m. and peak exiting occurring between 7:00-8:00 p.m. The Peru population exhibited unimodal entrance, with peak entry occurring between 10:00-11:00 p.m. and peak exiting occurring between 11:00-12:00 a.m. with a secondary smaller peak at 2:30 a.m. Entrance and exit behavioral patterns were significantly different between the Belize and Peru populations of An. darlingi (log-rank [Mantel-Cox] P < 0.001). Information from the present study will be used in the future to determine if there is a correlation between genotype and host-seeking behavior and can be used in the present for regional vector risk assessment.

  8. Thermal Orbital Environmental Parameter Study on the Propulsive Small Expendable Deployer System (ProSEDS) Using Earth Radiation Budget Experiment (ERBE) Data

    Science.gov (United States)

    Sharp, John R.; McConnaughey, Paul K. (Technical Monitor)

    2002-01-01

    The natural thermal environmental parameters used on the Space Station Program (SSP 30425) were generated by the Space Environmental Effects Branch at NASA's Marshall Space Flight Center (MSFC) utilizing extensive data from the Earth Radiation Budget Experiment (ERBE), a series of satellites which measured low earth orbit (LEO) albedo and outgoing long-wave radiation. Later, this temporal data was presented as a function of averaging times and orbital inclination for use by thermal engineers in NASA Technical Memorandum TM 4527. The data was not presented in a fashion readily usable by thermal engineering modeling tools and required knowledge of the thermal time constants and infrared versus solar spectrum sensitivity of the hardware being analyzed to be used properly. Another TM was recently issued as a guideline for utilizing these environments (NASA/TM-2001-211221) with more insight into the utilization by thermal analysts. This paper gives a top-level overview of the environmental parameters presented in the TM and a study of the effects of implementing these environments on an ongoing MSFC project, the Propulsive Small Expendable Deployer System (ProSEDS), compared to conventional orbital parameters that had been historically used.

  9. Radiation doses from common radiographic procedures: a ten year perspective

    International Nuclear Information System (INIS)

    Heggie, J.C.P.; Wilkinson, L.E.

    2000-01-01

    Using a semi-empirical model patient doses for a number of plain film radiographic procedures following the implementation of Computed Radiography (CR) technology in our Hospital have been evaluated. The results are presented in terms of the entrance surface dose (ESD) and the effective dose. A comparison of these results, with those reported previously for 1988, suggests that with the exception of chest radiography, patient doses have decreased although in many instances the decreases are not statistically significant. The finding for chest examinations stands apart from all others in that the introduction of CR technology has resulted in a substantial increase in patient dose for the PA view by at least 18%. The major reason for these apparently contradictory findings has its roots in the effectively variable speed of CR systems and the willingness of radiologists to accept more noise in some CR images

  10. Doses to patients from diagnostic radiology in Romania

    International Nuclear Information System (INIS)

    Iacob, O.; Diaconescu, C.

    2001-01-01

    Effective doses to over 2400 patients undergoing 20 of the most important types of X-ray examinations have been estimated from entrance surface doses or dose-area products, measured in 27 X-ray departments, and the appropriate conversion coefficients calculated by the NRPB for six mathematical phantoms representing 0, 1, 5, 10, 15 year old children and the adult. The patient-weighted mean effective dose from X-ray examinations performed annually in Romania is 1.32 mSv, with 1.40 mSv for the average adult patient and 0,59 mSv for the average paediatric patient. The corresponding annual collective effective dose is about 13,430 man Sv, with the main contribution belonging to adult patients (95%), the remainder of 5 percent - to paediatric patients. (author)

  11. 33 CFR 334.680 - Gulf of Mexico, southeast of St. Andrew Bay East Entrance, small-arms firing range, Tyndall Air...

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Gulf of Mexico, southeast of St... AND RESTRICTED AREA REGULATIONS § 334.680 Gulf of Mexico, southeast of St. Andrew Bay East Entrance... the Gulf of Mexico, southeast of St. Andrew Bay East Entrance within a rectangular area beginning at a...

  12. Capture and analysis of radiation dose reports for radiology

    International Nuclear Information System (INIS)

    Midgley, S.M.

    2014-01-01

    Radiographic imaging systems can produce records of exposure and dose parameters for each patient. A variety of file formats are in use including plain text, bit map images showing pictures of written text and radiation dose structured reports as text or extended markup language files. Whilst some of this information is available with image data on the hospital picture archive and communication system, access is restricted to individual patient records, thereby making it difficult to locate multiple records for the same scan protocol. This study considers the exposure records and dose reports from four modalities. Exposure records for mammography and general radiography are utilized for repeat analysis. Dose reports for fluoroscopy and computed tomography (CT) are utilized to study the distribution of patient doses for each protocol. Results for dosimetric quantities measured by General Radiography, Fluoroscopy and CT equipment are summarised and presented in the Appendix. Projection imaging uses the dose (in air) area product and derived quantities including the dose to the reference point as a measure of the air kerma reaching the skin, ignoring movement of the beam for fluoroscopy. CT uses the dose indices CTDIvol and dose length product as a measure of the dose per axial slice, and to the scanned volume. Suitable conversion factors are identified and used to estimate the effective dose to an average size patient (for CT and fluoroscopy) and the entrance skin dose for fluoroscopy.

  13. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  14. Measurement of radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Helmrot, E.; Carlsson, G. A.

    2005-01-01

    Patient dose audit is an important tool for quality control and it is important to have a well-defined and easy to use method for dose measurements. In dental radiology, the most commonly used dose parameters for the setting of diagnostic reference levels (DRLs) are the entrance surface air kerma (ESAK) for intraoral examinations and dose width product (DWP) for panoramic examinations. DWP is the air kerma at the front side of the secondary collimator integrated over the collimator width and an exposure cycle. ESAK or DWP is usually measured in the absence of the patient but with the same settings of tube voltage (kV), tube current (mA) and exposure time as with the patient present. Neither of these methods is easy to use, and, in addition, DWP is not a risk related quantity. A better method of monitoring patient dose would be to use a dose area product (DAP) meter for all types of dental examinations. In this study, measurements with a DAP meter are reported for intraoral and panoramic examinations. The DWP is also measured with a pencil ionisation chamber and the product of DWP and the height H (DWP x H) of the secondary collimator (measured using film) was compared to DAP. The results show that it is feasible to measure DAP using a DAP meter for both intraoral and panoramic examinations. The DAP is therefore recommended for the setting of DRLs. (authors)

  15. Radiation dose measurement in gastrointestinal studies

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Kappas, C.; Theodorou, K.

    2011-01-01

    Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedures. A total of 33 investigations of barium studies were measured by using thermoluminescence dosemeters. The result showed that the patient entrance surface doses were 12.6±10, 44.5±49 and 35.7±50 mGy for barium swallow, barium meal, follow through and enema, respectively. Effective doses were 0.2, 0.35 and 1.4 mSv per procedure for barium swallow, meal and enema respectively. Radiation doses were comparable with the previous studies. A written protocol for each procedure will reduce the inter-operator variations and will help to reduce unnecessary exposure. (authors)

  16. A comparison of dose savings of lead and lightweight aprons for shielding of 99m-Technetium radiation

    International Nuclear Information System (INIS)

    Warren-Forward, H.; Cardew, P.; Smith, B.; Clack, L.; McWhirter, K.; Johnson, S.; Wessel, K.

    2007-01-01

    Nuclear medicine technologists (NMTs) have the highest effective doses of radiation among medical workers. With increase in the use of lightweight materials in diagnostic radiography, the aim was to compare the effectiveness of lead and lightweight aprons in shielding from 99m-Technetium ( 99m Tc) gamma rays. The doses received from a scattering phantom to the entrance, 9 cm depth and exit of a phantom were measured with LiF:Mg, Cu, P thermoluminescent dosemeters (TLDs). Doses and spectra were assessed without no shielding, with 0.5-mm lead and lightweight aprons. The lead and lightweight aprons decreased entrance surface doses by 76 and 59%, respectively. The spectral analysis showed that the lightweight apron provided better dose reduction at energies 99m Tc labelled radiopharmaceutical. (authors)

  17. Differences in compliance with Surviving Sepsis Campaign recommendations according to hospital entrance time: day versus night.

    Science.gov (United States)

    Almeida, Mónica; Ribeiro, Orquídea; Aragão, Irene; Costa-Pereira, Altamiro; Cardoso, Teresa

    2013-04-23

    Higher compliance with Surviving Sepsis Campaign (SSC) recommendations has been associated with lower mortality. The authors evaluate differences in compliance with SSC 6-hour bundle according to hospital entrance time (day versus night) and its impact on hospital mortality. Prospective cohort study of all patients with community-acquired severe sepsis admitted to the intensive care unit of a large university tertiary care hospital, over 3.5 years with a follow-up until hospital discharge. Time to compliance with each recommendation of the SSC 6-hour bundle was calculated according to hospital entrance period: day (08:30 to 20:30) versus night (20:30 to 08:30). For the same periods, clinical staff composition and the number of patients attending the emergency department (ED) was also recorded. In this period 300 consecutive patients were included. Compliance rate was (night vs. day): serum lactate measurement 57% vs. 49% (P = 0.171), blood cultures drawn 59% vs. 37% (P 8 mmHg 45% vs. 29% (P = 0.021), and central venous oxygen saturation (SvcO₂) >70%, 7% vs. 2% (P = 0.082); fluids were administered in all patients with hypotension in both periods and vasopressors were administered in patients with hypotension not responsive to fluids in 100% vs. 99%. Time to get specific actions done was also different (night vs. day): serum lactate measurement (4.5 vs. 7 h, P = 0.018), blood cultures drawn (4 vs. 8 h, P night with a higher proportion of less differentiated doctors. The number of patients attending the Emergency Department was lower overnight. Hospital mortality rate was 34% in patients entering in the night period vs. 40% in those entering during the day (P = 0.281). Compliance with SSC recommendations was higher at night. A possible explanation might be the increased nurse to patient ratio in that period. Adjustment of the clinical team composition to the patients' demand is needed to increase compliance and improve prognosis.

  18. Doses in mammography. Preliminary study

    International Nuclear Information System (INIS)

    Marquez P, F.; Acosta R, N.; Universidad Nacional Mayor de San Marcos, Lima; Benavente, T.; Universidad Nacional Mayor de San Marcos, Lima; Poma, M.

    2002-01-01

    Mammography is the most important method to detect lesions in the breast with this technique one can detect small tumours before clear clinical symptoms appear. Mammographic image of require high quality standards due that the extremely low contrast between the normal and pathological areas in the breast, eg.g., they have similar attenuation and absorption coefficient. The x-ray mammographic systems, used in this study are Senographe 500t and Senographe DMR, a detector with a RadCal ionization chambers calibrated to the qualities of mammographic x-ray beams, and a breast simulator that is a phantoms of polymethylmethacrylate (PMMA) of several thicknesses with the equivalence of 50% of the glandular tissue. The results obtained indicate that the values of doses at the entrance surface of a breast (DES) are greater the reference value 20 mGy to 5,0 cm of PMMA and the values of the mean glandular dose (MGD) exceed the reference value of 2,1 mGy for 5,1 cm of compressed thick breast. We consider that the values high of the EDS and MGD are due that the x-ray systems no meeting in good condition or for used of x-ray spectra no suitable, so is recommendable be carried out test of quality control to the x-ray systems and also realize studies, or characterize the of x-ray mammographic spectra

  19. Optimization of the quality and dose in thorax general radiology

    International Nuclear Information System (INIS)

    Hwang, Suy Ferreira

    2001-01-01

    Image quality and radiation dose at skin entrance in chest radiography were studied for three exposure protocols, denoted as 1, 2 and 3. Protocol 1 represents the most used technique in radiology services in our country. This technique consists of the following parameters: 81 kV tube voltage, anti-scatter grid and 2 m focus-film distance. Protocol 2 uses the same parameters of the Protocol 1, without grid. Protocol 3 uses I 33kV without grid and 3,5 m focus-film distance. In Protocols 2 and 3 a 30 em air gap was used between patient and film. Two samples of 50 patients were radiographed in two different facilities, herein denoted 1 and 2. Protocol 1 was used in facility I to radiograph the first patient sample, and Protocols 2 and 3 were used in facility 2 to radiograph the second patient sample. Three experts in chest radiology evaluated the obtained chest images according anatomical quality criteria for this examination. For each patient exposure the radiation dose at skin entrance was measured. In this work, a chest phantom, containing test objects to evaluate quantitatively image quality, was made. The phantom was radiographed with the three protocols herein investigated. Results of this study showed clearly that Protocol 3 presents an average dose at skin entrance about half than Protocol 2 and about one third of Protocol 1. In regard to chest radiographic images and radiation dose, it was statistically demonstrated that the Protocol 3 is better than Protocols 1 and 2, with the improvement of the image quality and patient dose reduction in order of 3 times. This work also discusses the perspective of using optimized exposure technique proposed by Protocol 3 as an alternative technique far chest radiographic examinations to those currently used in our diagnostic radiology facilities. (author)

  20. Evaluation of patient dose in some mammography centres in Iran

    International Nuclear Information System (INIS)

    Paknyat, A.; Samarin, E. R. P.; Jeshvaghane, N. A.; Paydar, R.; Fasaei, B.; Karamloo, A.; Khosravi, H. R.; Deevband, M. R.

    2011-01-01

    High diagnostic sensitivity and specificity while maintaining the least dose to the patient is the ideal mammography. The objective of this work was to evaluate patient dose and image quality of mammograms to propose corrective actions. The image quality for 1242 patient in 7 mammography facilities in Tehran city was evaluated based on selected image quality criteria using a three-point scale. Clinical image quality, the entrance surface air kerma, the average glandular dose and optical density of films for standard PMMA phantom of 4.5 cm thickness were evaluated. The results showed that up to 72 % of mammograms were in good condition to be diagnosed, and only about 3.4 % of the images were unacceptable or with suboptimal quality. The entrance surface air kerma values were in the range of 3.8-10.5 mGy, average glandular dose 0.5-1.8 mGy and optical density of films 0.74-2.03. The image quality evaluation after correction actions, periodic image quality evaluation and using the correct equipment certainly will improve patient dose. (authors)

  1. An investigation into techniques for reducing doses from neo-natal radiographic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Wraith, C.M.; Martin, C.J. [Aberdeen Royal Hospitals NHS Trust (United Kingdom). Dept. of Bio-Medical Physics and Bio-Engineering; Stockdale, E.J.N.; McDonald, S.; Farquhar, B. [Royal Aberdeen Children`s Hospital (United Kingdom)

    1995-10-01

    A survey of radiation doses received by infants having radiography in a neo-natal unit was undertaken at Aberdeen Maternity Hospital. Options for dose reduction recommended by the CEC Lake Starnberg Group were investigated. Techniques were implemented for clinical evaluation after assessments of image quality with test objects and phantoms. Clinical image quality of radiographs was evaluated by paediatric radiologists using CEC criteria. Results revealed a clear relationship between entrance dose and patient weight, indicating that reference doses for infants could be linked to weight. (author).

  2. New hadron discovered at Entrance B (mother and baby doing fine)

    CERN Multimedia

    James Gillies

    2013-01-01

    Hadron: A heavy, strongly interacting particle. So say the dictionaries, and the definition seems entirely appropriate for the latest addition to a particular family that was passing CERN’s Entrance B on Monday afternoon en route for the Hôpital de la Tour.   The father of the baby (left) and the members of the CERN Fire Brigade and Medical Service dealing with the unexpected happy event. (Photo by D. Pagnani, CERN Fireman. The photo is reproduced by the CERN Bulletin with the agreement of the di Castro family.) The new "hadron" certainly showed the strength of its desire to interact with the world in arriving a little earlier than expected, causing its fraught parents to pull up the car and seek help at the first port of call. Luckily for them, that turned out to be CERN. Our medical service and ambulance personnel proved to be entirely up to the task. The fire brigade provided first aid, and was soon joined by the medical service, which ensured that mot...

  3. Traffic restrictions: Meyrin site and entrance of Prévessin site

    CERN Multimedia

    GS Department

    2010-01-01

    Between 10 April and 19 April 2010 a number of roads on the Meyrin site and at the entrance of the Prévessin site will be resurfaced. The work will be done by zones, as shown below: 12-14 April Intersection of Route Fermi and Route Gregory. Route Fermi, between Building 268 and Route Jentschke Route Fermi, Route Jentschke and Route Einstein, up to Building 593 and between Buildings 194 and 555. Plus Route Oppenheimer. 15 April Intersection of Route Bloch and Route Maxwell, and Route Maxwell itself. Route Sherrer between the overhead walkway (Building 50) and the exit from the carpark behind Building 4. 16 April and 19 April Route Fermi, Route Jentschke and Route Einstein, up to Building 593 and between Buildings 194 and 555. Prévessin site: from Route Adams to the access control Building. The construction works may result in some disruption to traffic. Users are requested to comply with the temporary traffic signs and arrangements.  Thank you for your understanding. GS/...

  4. Sleep Patterns and Academic Performance During Preparation for College Entrance Exam in Chinese Adolescents.

    Science.gov (United States)

    Wang, Guanghai; Ren, Fen; Liu, Zhijun; Xu, Guangxing; Jiang, Fan; Skora, Elizabeth; Lewin, Daniel S

    2016-04-01

    Deficient sleep is linked to detrimental outcomes in health and school performance for adolescents. This study characterized sleep patterns in Chinese adolescents preparing for the College Entrance Exam (CEE) and evaluated the association between sleep patterns, self-rated academic performance, and the CEE scores. A sample of 481 Chinese adolescents in 12th grade (ages 16-19 years) completed questionnaires about sleep patterns, academic performance, academic stress, and sociodemographic factors 4-6 weeks before the CEE in June 2013. The CEE scores for each student also were obtained. A total of 21% of the students had bedtimes after 12:00 am, 78.3% had sleep latency longer than 30 minutes, 14.6% had wake time earlier than 6:00 am, and the vast majority (94.4%) had sleep duration less than 8 hours. After adjusting for selected confounders such as academic stress, prolonged sleep latency was associated with poorer self-reported academic performance, and late bedtime was associated with higher CEE score. Our findings highlight the complex association between sleep and academic performance. Assessing and monitoring sleep patterns in adolescents during periods of high academic demand and stress may yield important recommendations for their health and safety as well as establishing optimal sleep and study habits. © 2016, American School Health Association.

  5. Pretreatment with oleic acid accelerates the entrance into the mitotic cycle of EGF-stimulated fibroblasts.

    Science.gov (United States)

    Zugaza, J L; Casabiell, X A; Bokser, L; Eiras, A; Beiras, A; Casanueva, F F

    1995-07-01

    We have previously demonstrated that pretreatment of several cell lines with cis-unsaturated fatty acids, like oleic acid, blocks epidermal growth factor (EGF)-induced early ionic signals, and in particular the [Ca2+]i rise. In the present work we show that this blockade does not alter EGF-stimulated cellular proliferation evaluated by direct cell counting, but induces a powerful enhancement in the pulsed thymidine incorporation assay. The lack of effect of oleic acid on EGF-stimulated cellular proliferation was confirmed by repeated cell counts, cumulative thymidine incorporation, and protein synthesis, but a clear synergistic effect between oleic acid and EGF was again obtained by means of time course experiments with pulsed thymidine. Combined flow cytometry analysis and cell counts at earlier times in EGF-stimulated cells showed that oleic acids accelerates the entrance of cells into the replicative cycle leading to an earlier cell division. Afterward, these oleic acid-pretreated cells became delayed by an unknown compensatory mechanism in such a way that at 48 h post-EGF, the cell count in control and oleic acid-pretreated cells was equal. In conclusion (a) oleic acid accelerates or enhances the EGF mitogenic action and (b) in the long term cells compensate the initial perturbation with respect to untreated cells. As a side observation, the widely employed pulsed thymidine incorporation method as a measure of cell division could be extremely misleading unless experimental conditions are well controlled.

  6. Experimental study of fluid flow in the entrance of a sinusoidal channel

    International Nuclear Information System (INIS)

    Oviedo-Tolentino, F.; Romero-Mendez, R.; Hernandez-Guerrero, A.; Giron-Palomares, B.

    2008-01-01

    An experimental flow visualization study of the entrance section of channels formed with sinusoidal plates was made. The experiments were conducted in a water tunnel and a laser illuminated particle tracking was used as the technique of flow visualization. The geometric parameters of the plates were maintained constant while the distance between plates, phase angle, and the Reynolds number were varied during the experiments. The flow regimes that were found in the experiments are steady, unsteady and significantly-mixed flows. Instabilities of the flow first appear near the exit of the channel, and move closer to the inlet waves as the Reynolds number grows, but in the first wave from inlet the flow is always steady. The results show that, for all other parameters fixed, the Reynolds number at which unsteady flow first appears grows with the distance between plates. The phase angle that best promotes unsteady flow depends on the average distance between plates: for certain average distance between plates, there is a phase angle that best disturbs the flow. For the set of parameters used in this experiment, a channel with eight waves is sufficiently long and the flow features presented in the first eight waves of a longer channel will be similar to what was observed here

  7. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    Science.gov (United States)

    Legin, G A; Bondarchuk, A O; Perebetjuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  8. Optimal Coordinated Control of Power Extraction in LES of a Wind Farm with Entrance Effects

    Directory of Open Access Journals (Sweden)

    Jay P. Goit

    2016-01-01

    Full Text Available We investigate the use of optimal coordinated control techniques in large eddy simulations of wind farm boundary layer interaction with the aim of increasing the total energy extraction in wind farms. The individual wind turbines are considered as flow actuators, and their energy extraction is dynamically regulated in time, so as to optimally influence the flow field. We extend earlier work on wind farm optimal control in the fully-developed regime (Goit and Meyers 2015, J. Fluid Mech. 768, 5–50 to a ‘finite’ wind farm case, in which entrance effects play an important role. For the optimal control, a receding horizon framework is employed in which turbine thrust coefficients are optimized in time and per turbine. Optimization is performed with a conjugate gradient method, where gradients of the cost functional are obtained using adjoint large eddy simulations. Overall, the energy extraction is increased 7% by the optimal control. This increase in energy extraction is related to faster wake recovery throughout the farm. For the first row of turbines, the optimal control increases turbulence levels and Reynolds stresses in the wake, leading to better wake mixing and an inflow velocity for the second row that is significantly higher than in the uncontrolled case. For downstream rows, the optimal control mainly enhances the sideways mean transport of momentum. This is different from earlier observations by Goit and Meyers (2015 in the fully-developed regime, where mainly vertical transport was enhanced.

  9. Far-from-equilibrium bidirectional transport system with constrained entrances competing for pool of limited resources

    Science.gov (United States)

    Verma, Atul Kumar; Sharma, Natasha; Gupta, Arvind Kumar

    2018-02-01

    Motivated by the wide occurrence of limited resources in many real-life systems, we investigate two-lane totally asymmetric simple exclusion process with constrained entrances under finite supply of particles. We analyze the system within the framework of mean-field theory and examine various complex phenomena, including phase separation, phase transition, and symmetry breaking. Based on the theoretical analysis, we analytically derive the phase boundaries for various symmetric as well as asymmetric phases. It has been observed that the symmetry-breaking phenomenon initiates even for very small number of particles in the system. The phases with broken symmetry originates as shock-low density phase under limited resources, which is in contrast to the scenario with infinite number of particles. As expected, the symmetry breaking continues to persist even for higher values of system particles. Seven stationary phases are observed, with three of them exhibiting symmetry-breaking phenomena. The critical values of a total number of system particles, beyond which various symmetrical and asymmetrical phases appear and disappear are identified. Theoretical outcomes are supported by extensive Monte Carlo simulations. Finally, the size-scaling effect and symmetry-breaking phenomenon on the simulation results have also been examined based on particle density histograms.

  10. EARLY ENTRANCE CO-PRODUCTION PLANT - DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    International Nuclear Information System (INIS)

    Unknown

    2001-01-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors Texaco Power and Gasification, SASOL Technology Ltd., and Nexant Inc. entered into a Cooperative Agreement DE-FC26-00NT40693 with the US Department of Energy (DOE), National Energy Technology Laboratory (NETL) to assess the techno-economic viability of building an Early Entrance Co-Production Plant (EECP) in the US to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co-product. The EECP designs emphasize on recovery and gasification of low-cost coal waste (culm) from coal clean operations and will assess blends of the culm and coal or petroleum coke as feedstocks. The project is being carried out in three phases. Phase I involves definition of concept and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase II consists of an experimental testing program designed to validate the coal waste mixture gasification performance. Phase III involves updating the original EECP design, based on results from Phase II, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 BPD coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania

  11. Entrance channel influence on the formation and decay of hot nuclei

    International Nuclear Information System (INIS)

    Harar, S.

    1987-04-01

    Different entrance channels have been investigated to form very hot nuclei and to study their decay properties. i) Argon and Nickel projectiles accelerated around the Fermi energy show that central collisions induce momentum transfers to target nuclei which are proportional to the mass of the projectile and not to its velocities in the studied energy range. The preequilibrium model fits nicely the experimental results. The decay properties of the fission products for hot nuclei will be presented. Both head-on collisions and peripheral massive transfers contribute to the formation of very excited nuclei. The question of the influence of the energy deposit in the composite like system in limiting their yields is discussed. ii) Investigations have been also achieved with alpha projectiles at much higher incident energy (around 1 GeV/u). It is shown that hot and thermalized nuclei are also formed even when the nucleon-nucleon collisions are predominant. A sensitive parameter of the transition from binary fission to multifragmentation seems to be the energy deposit in the target residues rather than the projectile velocity

  12. Evaluation of a Model for Predicting the Tidal Velocity in Fjord Entrances

    Energy Technology Data Exchange (ETDEWEB)

    Lalander, Emilia [The Swedish Centre for Renewable Electric Energy Conversion, Division of Electricity, Uppsala Univ. (Sweden); Thomassen, Paul [Team Ashes, Trondheim (Norway); Leijon, Mats [The Swedish Centre for Renewable Electric Energy Conversion, Division of Electricity, Uppsala Univ. (Sweden)

    2013-04-15

    Sufficiently accurate and low-cost estimation of tidal velocities is of importance when evaluating a potential site for a tidal energy farm. Here we suggest and evaluate a model to calculate the tidal velocity in fjord entrances. The model is compared with tidal velocities from Acoustic Doppler Current Profiler (ADCP) measurements in the tidal channel Skarpsundet in Norway. The calculated velocity value from the model corresponded well with the measured cross-sectional average velocity, but was shown to underestimate the velocity in the centre of the channel. The effect of this was quantified by calculating the kinetic energy of the flow for a 14-day period. A numerical simulation using TELEMAC-2D was performed and validated with ADCP measurements. Velocity data from the simulation was used as input for calculating the kinetic energy at various locations in the channel. It was concluded that the model presented here is not accurate enough for assessing the tidal energy resource. However, the simplicity of the model was considered promising in the use of finding sites where further analyses can be made.

  13. EARLY ENTRANCE CO-PRODUCTION PLANT - DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2001-12-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors Texaco Power & Gasification, SASOL Technology Ltd., and Nexant Inc. entered into a Cooperative Agreement DE-FC26-00NT40693 with the US Department of Energy (DOE), National Energy Technology Laboratory (NETL) to assess the techno-economic viability of building an Early Entrance Co-Production Plant (EECP) in the US to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co-product. The EECP designs emphasize on recovery and gasification of low-cost coal waste (culm) from coal clean operations and will assess blends of the culm and coal or petroleum coke as feedstocks. The project is being carried out in three phases. Phase I involves definition of concept and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase II consists of an experimental testing program designed to validate the coal waste mixture gasification performance. Phase III involves updating the original EECP design, based on results from Phase II, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 BPD coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania.

  14. EARLY ENTRANCE CO-PRODUCTION PLANT - DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2003-01-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors Texaco Power & Gasification (now ChevronTexaco), SASOL Technology Ltd., and Nexant Inc. entered into a Cooperative Agreement DE-FC26-00NT40693 with the U. S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) to assess the technoeconomic viability of building an Early Entrance Co-Production Plant (EECP) in the United States to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co-product. The EECP design includes recovery and gasification of low-cost coal waste (culm) from physical coal cleaning operations and will assess blends of the culm with coal or petroleum coke. The project has three phases. Phase I is the concept definition and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase II is an experimental testing program designed to validate the coal waste mixture gasification performance. Phase III updates the original EECP design based on results from Phase II, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 barrel per day (BPD) coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania. The current report covers the period performance from July 1, 2002 through September 30, 2002.

  15. Work on the Building 4 car park and closure of Entrance A

    CERN Multimedia

    2015-01-01

    From 6 July to 31 October 2015, the GS department will be carrying out renovation work on the car park next to Buildings 4 and 5. This work is aimed at improving safety on and around the car park for all users, particularly children attending the nursery school, pedestrians and cyclists.   Layout of the upcoming car park.   The work on the car park will be conducted in two stages so that half of the parking spaces will always be available, in order to limit the impact on users as much as possible (the closed-off areas will be clearly indicated). When the work is completed, the car park will have been completely renovated, with new surfacing and road markings, high-quality lighting and more parking spaces (+5%). During the work, part of the car park will be inaccessible, which is likely to make it more difficult to find a parking space. We therefore invite you to park in the Globe car park during this period. The renovation work will also affect Entrance A (Route Bell), which will be fitt...

  16. A computer-assisted procedure for estimating patient exposure and fetal dose in radiographic examinations

    International Nuclear Information System (INIS)

    Glaze, S.; Schneiders, N.; Bushong, S.C.

    1982-01-01

    A computer program for calculating patient entrance exposure and fetal dose for 11 common radiographic examinations was developed. The output intensity measured at 70 kVp and a 30-inch (76-cm) source-to-skin distance was entered into the program. The change in output intensity with changing kVp was examined for 17 single-phase and 12 three-phase x-ray units. The relationships obtained from a least squares regression analysis of the data, along with the technique factors for each examination, were used to calculate patient exposure. Fetal dose was estimated using published fetal dose in mrad (10 -5 Gy) per 1,000 mR (258 μC/kg) entrance exposure values. The computations are fully automated and individualized to each radiographic unit. The information provides a ready reference in large institutions and is particularly useful at smaller facilities that do not have available physicists who can make the calculations immediately

  17. A computer-assisted procedure for estimating patient exposure and fetal dose in radiographic examinations

    International Nuclear Information System (INIS)

    Glaze, S.; Schneiders, N.; Bushong, S.C.

    1982-01-01

    A computer program for calculating patient entrance exposure and fetal dose for 11 common radiographic examinations was developed. The output intensity measured at 70 kVp and a 30-inch (76-cm) source-to-skin distance was entered into the program. The change in output intensity with changing kVp was examined for 17 single-phase and 12 three-phase x-ray units. The relationships obtained from a least squares regression analysis of the data, along with the technique factors for each examination, were used to calculate patient exposure. Fetal dose was estimated using published fetal dose in mrad (10(-5) Gy) per 1,000 mR (258 microC/kg) entrance exposure values. The computations are fully automated and individualized to each radiographic unit. The information provides a ready reference in large institutions and is particularly useful at smaller facilities that do not have available physicians who can make the calculations immediately

  18. The difference in backscatter factors of diagnostic X-rays by the difference in the scattering medium and in the objective dose

    International Nuclear Information System (INIS)

    Kato, Hideki; Sakai, Keita; Uchiyama, Mizuki; Suzuki, Kentaro

    2016-01-01

    The diagnostic reference levels (DRLs) of the general X-ray radiography are defined by the absorbed dose of air at the entrance surface with backscattered radiation from a scattering medium. Generally, the entrance surface dose of the general X-ray radiography is calculated from measured air kerma of primary X-ray multiplied by a backscatter factor (BSF). However, the BSF data employed at present used water for scattering medium, and was calculated based on the water-absorbed dose by incident primary photons and backscattered photons from the scattering medium. In the calculation of air dose at the entrance surface defined in DRLs, there are no theoretical consistencies for using BSF based on water dose, and this may be a cause of calculation error. In this paper, we verified the difference in BSF by the difference in the scattering medium and by the difference in the objective dose by means of the Monte Carlo simulation. In this calculation, the scattering medium was set as water and the soft-tissue, and the objective dose was set as air dose, water dose, soft-tissue dose, and skin dose. The difference in BSF calculated by the respective combination was at most about 1.3% and was less than 1% in most cases. In conclusion, even if the entrance surface dose defined by DRLs of general X-ray radiography is calculated using BSF, which set both the scattering medium and the object substance of the absorbed dose as water, a so big error doesn't show. (author)

  19. Estimation of absorbed dose and its biological effects in subjects undergoing neuro interventional radiological procedures

    International Nuclear Information System (INIS)

    Basheerudeen, Safa Abdul Syed; Subramanian, Vinodhini; Venkatachalam, Perumal; Joseph, Santosh; Selvam, Paneer; Jose, M.T.; Annalakshmi, O.

    2016-01-01

    Radiological imaging has many applications due to its non-invasiveness, rapid diagnosis of life threatening diseases, and shorter hospital stay which benefit patients of all age groups. However, these procedures are complicated and time consuming, which use repeated imaging views and radiation, thereby increasing patient dose, and collective effective dose to the background at low doses. The effects of high dose radiation are well established. However, the effects of low dose exposure remain to be determined. Therefore, investigating the effect on medically exposed individuals is an alternative source to understand the low dose effects of radiation. The ESD (Entrance Surface Dose) was recorded using Lithium borate based TL dosimeters to measure the doses received by the head, neck and shoulder of the study subjects (n = 70) who underwent procedures like cerebral angiography, coiling, stenting and embolization

  20. Radiation dose in mammography: an energy-balance approach

    International Nuclear Information System (INIS)

    Shrivastava, P.N.

    1981-01-01

    An energy-balance approach for calculation of mean, integral, and midpoint doses in mammography is introduced. Estimation of mean absorbed dose for individual applications is described. Differences in breast composition and thickness are accounted for by simple measurements of entrance and exit exposures. Calculations made for a range of xeromammographic techniques used at various breast cancer detection centers show that although increasing the beam h.v.l. dramatically decreases breast surface exposure, it is insignificant in lowering mean breast dose or radiation risk. Thus selection of a moderate h.v.l. to optimize image quality (soft-tissue contrast) in xeromammography may be more beneficial than unduly increasing h.v.l. merely to reduce surface exposure. The mean breast dose per mammogram with low-h.v.l. screen-film techniques was 3 to 9 times lower than for xeromammography, suggesting that general acceptance of screen-film techniques can significantly reduce the risk associated with mammography

  1. Dose assessment of an accidental exposure at IPNS

    International Nuclear Information System (INIS)

    Torres, M.M.C.

    1996-01-01

    Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose rates ranged from 550 mrem/min to 2,850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem

  2. Dose in conventional radiography; Dosis en radiografia convencional

    Energy Technology Data Exchange (ETDEWEB)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98000 Zacatecas (Mexico)

    2011-10-15

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  3. The dose and image quality in mammography in Macedonia

    International Nuclear Information System (INIS)

    Gershan, V.

    2007-01-01

    Complete test of publication follows. Mean Glandular Dose (MGD), dose distribution, phantom and quality of the real mammogram were studied for the first time in Macedonia. The study was conducted to review the condition of mammography equipment, to access the dose and image quality in mammography practices in Macedonia.. The purpose was to find out the weak points in the mammography practices in order to suggest improvements in the practices and establish quality control procedures. Under evaluation were 12 monographic machines. MGD was estimated using Entrance Surface Air KERMA at the breast surface K f measured free in air and appropriate conversion factors. Dose survey was curried by measurement and calculated of the HVLs and radiation output for 25-32 kVp and keeping record of the clinical parameters (breast thickness, kVp, mAs). Image quality was evaluated using the Mammographic Accreditation Phantom Gammex 156, PMMA plates and test tool for film processing.

  4. An Update on the Depth-Dose Curve of Antiprotons

    DEFF Research Database (Denmark)

    Taasti, Vicki Trier; Holzscheiter, Michael H.; Knudsen, Helge

    in water. The experimental results are compared with the Monte Carlo particle transport code SHIELD-HIT12A. Contrary to [1], here the full ionization chamber is simulated and the dose is scored in the ionization chamber air gap. Stopping power ratios are determined as well in order to translate...... the simulated dose to dose-to-water formalism. Results: Generally, the experimental data are in good agreement with the simulated dose on an absolute scale in the plateau region. However some deviations are found near the annihilation peak. A full geometric description of the ionization chamber simulation...... improves the situation, in particular on the upstream side of the Bragg-peak. This is attributed to a different spectrum of annihilation products created in the entrance window of the ionization chamber in comparison to the case of simply simulating annihilation taking place on water. Yet, a large portion...

  5. Dose assessment of an accidental exposure at the IPNS

    International Nuclear Information System (INIS)

    Campos Torres, M.M.

    1995-02-01

    Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose ranged from 550 mrem/min to 2850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenetic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem

  6. Causal Effects of Single-Sex Schools on College Entrance Exams and College Attendance: Random Assignment in Seoul High Schools

    OpenAIRE

    Park, Hyunjoon; Behrman, Jere R.; Choi, Jaesung

    2013-01-01

    Despite the voluminous literature on the potentials of single-sex schools, there is no consensus on the effects of single-sex schools because of student selection of school types. We exploit a unique feature of schooling in Seoul—the random assignment of students into single-sex versus coeducational high schools—to assess causal effects of single-sex schools on college entrance exam scores and college attendance. Our validation of the random assignment shows comparable socioeconomic backgroun...

  7. A Two-Stage DEA to Analyze the Effect of Entrance Deregulation on Iranian Insurers: A Robust Approach

    OpenAIRE

    Jalali Naini, Seyed Gholamreza; Nouralizadeh, Hamid Reza

    2012-01-01

    We use two-stage data envelopment analysis (DEA) model to analyze the effects of entrance deregulation on the efficiency in the Iranian insurance market. In the first stage, we propose a robust optimization approach in order to overcome the sensitivity of DEA results to any uncertainty in the output parameters. Hence, the efficiency of each ongoing insurer is estimated using our proposed robust DEA model. The insurers are then ranked based on their relative efficiency scores for an eight-year...

  8. Evaluation of the Kerma at the entrance of the labyrin thin in facilities with Co-60 HDR brachytherapy

    International Nuclear Information System (INIS)

    Pujades, M. C.; Granero, D.; Ballester, F.; Perez-Calatayud, J.; Vijande, J.

    2013-01-01

    The purpose of this study is to evaluate the kerma's collision at the entrance of the labyrinth adapting the methodology of the NCRP-151 to a bunker of brachytherapy with Co-60, similar to the one carried out in a previous work with HDR Ir-192. To validate the result is simulated using techniques Monte Carlo (MC) two typical designs of HDR with Co-60 bunker. (Author)

  9. Bolsa Bay, California, Proposed Ocean Entrance System Study. Report 2. Comprehensive Shoreline Response Computer Simulation, Bolsa Bay, California

    Science.gov (United States)

    1990-04-01

    Southern California Bight is affected by a land-sea breeze pattern. A variation in flow is caused by the heating of the land surface during the day, and...1980). 27. The success of the inlet channel at Agua Hedionda indicates that a stable non-navigable entrance at Bolsa Chica could be feasible provided a...dual jetty system similar to Agua Hedionda is incorporated into the design. However, structures that penetrate into the active surf zone are expected

  10. Non scholae, sed vitae discimus!

    Directory of Open Access Journals (Sweden)

    Ursula Mulley

    2013-12-01

    Full Text Available "We want our young people exposed to ICT in school from the very beginning, and we want teachers who are confident to share their knowledge", mit diesen Aussagen der EU-Kommissarin for Education, Nellie Kroes (Europäische Kommision, 2013, wird deutlich, dass LehrerInnen aufgefordert sind, den ihnen anvertrauten Kindern einen sinnvollen Umgang mit Medien nahe zu bringen. Wie wichtig das Ausbilden dieser Fähigkeiten und das Erwerben der Kenntnisse in diesem Bereich ist, kann durch die Tatsache, dass die Europäische Union digitale Kompetenz zu einer der acht Schlüsselkompetenzen zählt und von der Europäischen Kommission in ihrer "Digitalen Agenda" (Europäische Kommission, 2006 nachweislich eingefordert wird, erkannt werden. Studien, wie beispielsweise die 3. Oö. Kinder-Medien-Studie (Oö. Kinder-Medien-Studie, 2012 belegen, dass Kinder bereits vor dem Schuleintritt mit neuen Technologien und dem Internet Erfahrungen sammeln. Diese Erkenntnisse führen zur Fragestellung, welche Maßnahmen im schulischen Kontext gesetzt werden müssen, um SchülerInnen im Bereich der Medienbildung zu unterstützen und auf den individuellen und kollektiven Habitus im Bereich der Medienbildung einzugehen. Eine Arbeitsgruppe mit ExpertInnen (digi.komp, 2013a erstellte im Auftrag des Bundesministeriums für Unterricht, Kunst und Kultur zu diesem Zweck einen Referenzrahmen für digitale Kompetenzen für SchülerInnen des Primarbereichs. Dieses digitale Kompetenzmodell mit zahlreichen Anwendungsbeispielen ermöglicht allen SchulpartnerInnen in Österreich eine Orientierung beim Arbeiten mit "Neuen" Medien. Es soll SchülerInnen dazu befähigen, dass sie am Ende der vierten Schulstufe Kompetenzen im Bereich der ICT aufweisen.

  11. Early entrance to the job market and its effect on adult health: evidence from Brazil.

    Science.gov (United States)

    Kassouf, A L; McKee, M; Mossialos, E

    2001-03-01

    To determine the effect of employment in childhood on self-reported health in adulthood. A cross-sectional household survey, with households selected through two-stage sampling, in urban and rural areas in the northeast and southeast of Brazil. A total of 4940 individuals, aged between 18 and 65 years, were included. The main outcome measure was self-reported health. There has been a marked reduction in the proportion of people starting work during childhood although, even in the youngest age group, nearly 20% of males began work when under 10. Early entrance into the labour market is strongly associated with low levels of both education and income, with income differentials remaining at later ages. Age starting work is also linked to current household income, with approximately 35% of those starting work when 15 or over currently in the top quartile of household income, compared with 12% of those starting work when under 10. Males, those living in rural areas, and non-whites are most likely to start work early. In univariate analyses, the younger a person started working, the greater the probability of reporting less than good health status as an adult. This persists through all ages, although the difference attenuates with increasing age. In multivariate analyses, adjustment for education or household income substantially reduces the effect but fails to eliminate it in several age bands up to the age of 48, indicating that age starting work has an independent effect on self-reported health in adulthood. The debate about the appropriate policy response to child labour is complex, requiring a balance between protecting the health of the child and safeguarding the income of the family. These findings indicate the need for more research on the long-term sequelae of beginning work at an early age.

  12. OH vibrational activation and decay dynamics of CH4-OH entrance channel complexes

    International Nuclear Information System (INIS)

    Wheeler, Martyn D.; Tsiouris, Maria; Lester, Marsha I.; Lendvay, Gyoergy

    2000-01-01

    Infrared spectroscopy has been utilized to examine the structure and vibrational decay dynamics of CH 4 -OH complexes that have been stabilized in the entrance channel to the CH 4 +OH hydrogen abstraction reaction. Rotationally resolved infrared spectra of the CH 4 -OH complexes have been obtained in the OH fundamental and overtone regions using an IR-UV (infrared-ultraviolet) double-resonance technique. Pure OH stretching bands have been identified at 3563.45(5) and 6961.98(4) cm-1 (origins), along with combination bands involving the simultaneous excitation of OH stretching and intermolecular bending motions. The infrared spectra exhibit extensive homogeneous broadening arising from the rapid decay of vibrationally activated CH 4 -OH complexes due to vibrational relaxation and/or reaction. Lifetimes of 38(5) and 25(3) ps for CH 4 -OH prepared with one and two quanta of OH excitation, respectively, have been extracted from the infrared spectra. The nascent distribution of the OH products from vibrational predissociation has been evaluated by ultraviolet probe laser-induced fluorescence measurements. The dominant inelastic decay channel involves the transfer of one quantum of OH stretch to the pentad of CH 4 vibrational states with energies near 3000 cm-1. The experimental findings are compared with full collision studies of vibrationally excited OH with CH 4 . In addition, ab initio electronic structure calculations have been carried out to elucidate the minimum energy configuration of the CH 4 -OH complex. The calculations predict a C 3v geometry with the hydrogen of OH pointing toward one of four equivalent faces of the CH 4 tetrahedron, consistent with the analysis of the experimental infrared spectra. (c) 2000 American Institute of Physics

  13. EARLY ENTRANCE CO-PRODUCTION PLANT - DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    International Nuclear Information System (INIS)

    Unknown

    2001-01-01

    Waste Processors Management Inc. (WMPI), along with its subcontractors entered into a cooperative agreement with the USDOE to assess the techno-economic viability of building an Early Entrance Co-Production Plant (EECP) in the US that produces ultra clean Fischer-Tropsch transportation fuels with either power or steam as the major co-product. The EECP will emphasize on reclaiming and gasifying low-cost coal waste and/or its mixture as the primary feedstocks. The project consists of three phases. Phase I objectives include conceptual development, technical assessment, feasibility design and economic evaluation of a Greenfield commercial co-production plant and a site specific demonstration EECP to be located adjacent to the existing WMPI Gilberton Power Station. There is very little foreseen design differences between the Greenfield commercial coproduction plant versus the EECP plant other than: The greenfield commercial plant will be a stand alone FT/power co-production plant, potentially larger in capacity to take full advantage of economy of scale, and to be located in either western Pennsylvania, West Virginia or Ohio, using bituminous coal waste (gob) and Pennsylvania No.8 coal or other comparable coal as the feedstock; The EECP plant, on the other hand, will be a nominal 5000 bpd plant, fully integrated into the Gilbertson Power Company's Cogeneration Plant to take advantage of the existing infrastructure to reduce cost and minimize project risk. The Gilberton EECP plant will be designed to use eastern Pennsylvania anthracite coal waste and/or its mixture as feedstock

  14. Entrance and Survival of Brucella pinnipedialis Hooded Seal Strain in Human Macrophages and Epithelial Cells

    Science.gov (United States)

    Briquemont, Benjamin; Sørensen, Karen K.; Godfroid, Jacques

    2013-01-01

    Marine mammal Brucella spp. have been isolated from pinnipeds (B. pinnipedialis) and cetaceans (B. ceti) from around the world. Although the zoonotic potential of marine mammal brucellae is largely unknown, reports of human disease exist. There are few studies of the mechanisms of bacterial intracellular invasion and multiplication involving the marine mammal Brucella spp. We examined the infective capacity of two genetically different B. pinnipedialis strains (reference strain; NTCT 12890 and a hooded seal isolate; B17) by measuring the ability of the bacteria to enter and replicate in cultured phagocytes and epithelial cells. Human macrophage-like cells (THP-1), two murine macrophage cell lines (RAW264.7 and J774A.1), and a human malignant epithelial cell line (HeLa S3) were challenged with bacteria in a gentamicin protection assay. Our results show that B. pinnipedialis is internalized, but is then gradually eliminated during the next 72 – 96 hours. Confocal microscopy revealed that intracellular B. pinnipedialis hooded seal strain colocalized with lysosomal compartments at 1.5 and 24 hours after infection. Intracellular presence of B. pinnipedialis hooded seal strain was verified by transmission electron microscopy. By using a cholesterol-scavenging lipid inhibitor, entrance of B. pinnipedialis hooded seal strain in human macrophages was significantly reduced by 65.8 % (± 17.3), suggesting involvement of lipid-rafts in intracellular entry. Murine macrophages invaded by B. pinnipedialis do not release nitric oxide (NO) and intracellular bacterial presence does not induce cell death. In summary, B. pinnipedialis hooded seal strain can enter human and murine macrophages, as well as human epithelial cells. Intracellular entry of B. pinnipedialis hooded seal strain involves, but seems not to be limited to, lipid-rafts in human macrophages. Brucella pinnipedialis does not multiply or survive for prolonged periods intracellulary. PMID:24376851

  15. Entrance into elementary scholl at six age? What say childrens and their parents

    Directory of Open Access Journals (Sweden)

    Caroline Raniro

    2017-06-01

    Full Text Available From the approval of the Law 11.114, published in 05/16/2005, which established enrolment in elementary school from children with six years, from Law 11.274, published in 02/06/2006, which extends the duration of elementary school for nine years and considering family and school with relevant figures to the life of the children, this article is aimed to divulge partial results with how understand parents and himself about insertion process of children with six years in the elementary school. This study is a qualitative nature and based in bioecological perspective of human development established by Bronfenbrenner (1996, whose emphasizes the interconnection between various levels of the ecological system. Semi-structured interviews were conducted with fifteen children and their parents, to understand perceptions of the individuals when entrance into elementary school. The interviews locations were a municipal school located in one city of the Sao Paulo State and the own residence of the parents. The data collection illustrated, predominantly, that parents and children agree with the insertion with six years in the elementary school. All seemed to have grown accustomed to the new model and are satisfied with previous results that it can offer nowadays. The students seemed to maintain a satisfactory relationship in school, are motivated, interested and want to read and write, an expectation that meets with parents affirmation. Whilst, sometimes, the children are tired, they value and have clarity of the importance of teaching-learning process. Attend the early childhood education seems to have contributed to the adaptation in elementary school. The family context reveals parents that are value and interested in the education of the children, trying to follow them, even when the family environment and disadvantaged by adverse situations. The results will certainly contribute to the Education School, mainly because there are few studies that

  16. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  17. 14C-2-deoxyglucose uptake in the ground squirrel brain during entrance to and arousal from hibernation

    International Nuclear Information System (INIS)

    Kilduff, T.S.; Miller, J.D.; Radeke, C.M.; Sharp, F.R.; Heller, H.C.

    1990-01-01

    Neuronal activity underlying various phases of the mammalian hibernation cycle was investigated using the 14 C-2-deoxyglucose (2DG) method. Relative 2DG uptake (R2DGU) values were computed for 96 brain regions across 7 phases of the hibernation cycle: euthermia, 3 body temperature (Tb) intervals during entrance into hibernation, stable deep hibernation, and 2 Tb intervals during arousal from hibernation. Multivariate statistical techniques were employed to identify objectively groups of brain regions whose R2DGU values showed a similar pattern across all phases of hibernation. Factor analysis revealed that most of the variability in R2DGU values for the 96 brain regions across the entire cycle could be accounted for by 3 principal factors. These factors could accurately discriminate the various phases of hibernation on the basis of the R2DGU values alone. Three hypothalamic and 3 cortical regions were identified as possibly mediating the entrance into hibernation because they underwent a change in R2DGU early in entrance into hibernation and loaded strongly on one of the principal factors. Another 4 hypothalamic regions were similarly identified as possibly causally involved in the arousal from hibernation. These results, coupled with characteristic changes in ordinal rank of the 96 brain regions in each phase of hibernation, support the concept that mammalian hibernation is an active, integrated orchestration of neurophysiological events rather than a state entered through a passive process

  18. SU-E-T-235: Monte Carlo Analysis of the Dose Enhancement in the Scalp of Patients Due to Titanium Plate Backscatter During Post-Operative Radiotherapy

    International Nuclear Information System (INIS)

    Hardin, M; Elson, H; Lamba, M; Wolf, E; Warnick, R

    2014-01-01

    Purpose: To quantify the clinically observed dose enhancement adjacent to cranial titanium fixation plates during post-operative radiotherapy. Methods: Irradiation of a titanium burr hole cover was simulated using Monte Carlo code MCNPX for a 6 MV photon spectrum to investigate backscatter dose enhancement due to increased production of secondary electrons within the titanium plate. The simulated plate was placed 3 mm deep in a water phantom, and dose deposition was tallied for 0.2 mm thick cells adjacent to the entrance and exit sides of the plate. These results were compared to a simulation excluding the presence of the titanium to calculate relative dose enhancement on the entrance and exit sides of the plate. To verify simulated results, two titanium burr hole covers (Synthes, Inc. and Biomet, Inc.) were irradiated with 6 MV photons in a solid water phantom containing GafChromic MD-55 film. The phantom was irradiated on a Varian 21EX linear accelerator at multiple gantry angles (0–180 degrees) to analyze the angular dependence of the backscattered radiation. Relative dose enhancement was quantified using computer software. Results: Monte Carlo simulations indicate a relative difference of 26.4% and 7.1% on the entrance and exit sides of the plate respectively. Film dosimetry results using a similar geometry indicate a relative difference of 13% and -10% on the entrance and exit sides of the plate respectively. Relative dose enhancement on the entrance side of the plate decreased with increasing gantry angle from 0 to 180 degrees. Conclusion: Film and simulation results demonstrate an increase in dose to structures immediately adjacent to cranial titanium fixation plates. Increased beam obliquity has shown to alleviate dose enhancement to some extent. These results are consistent with clinically observed effects

  19. Development of personal dose monitoring system using wireless data transmission device

    International Nuclear Information System (INIS)

    Inui, Daisuke; Nakashima, Sadao

    2008-01-01

    Radiation workers working in radiation controlled area in nuclear power plants etc., are required to carry a dosimeters by regulation law. The workers are controlled daily on personal exposure dose by reading out the exposure dose information of the dosimeters with an area access control gate installed at the entrance of the radiation controlled area. This type of personal dose monitoring system has a problem that each worker can get his personal dose data only at the entrance of the radiation controlled area several times a day. We developed a system to get the real-time acquisition of personal dose data especially for workers working in a high dose area. This system is generally composed of a dosimeter with a wireless attachment, relay station, and monitor. Some relay stations set in main work places in the radiation controlled area can collect real-time personal dose data of each dosimeter carried by workers at the work place with the relay stations, and transmit it to the monitor to get personal dose data of individual workers. A wireless communication system between dosimeters and relay stations is applied to collect efficiently all personal dose data in the work place. (author)

  20. Reduction of radiation dose during the complex explorations using additional filter in pediatric patients

    International Nuclear Information System (INIS)

    Minguez, C.; Espana, M. L.; Castro, P.; Sevillano, D.; Lopez Franco, P.

    2006-01-01

    The aim of this study is to investigate the influence on image contrast, tube load and effective dose in paediatric fluoroscopy using added filtration. A Philips Omnidiagnosti is used in Nino Jesus Hospital and was therefore chosen for radiation dose measurements. The phantom consisted of varying methacrylate thickness to represent different patients sizes. All measurements were performed in automatic mode. For each exposure and additional filtration added the following data was recorded: tube voltage, tube current, air kerma rate on phantom surface and brightness on the image monitor. An 2026 electrometer (Radical Corporation) in conjunction with a model 2025-60 ion chamber were used for entrance dose measurements and the luxometer IL-400A (International Light) was used for brightness measurements on the image monitor: Evaluation of image quality was performed using a Leeds TOR TVF test object. Finally, the program PCXMC 1.5 based on the Monte Carlo method was used for calculating organ doses and the effective dose in fluoroscopy examinations. By increasing the filtration of the x-ray tube 1st Entrance radiation exposure can be decreased 58%, organ dose up to 40%, and effective dose up to 44%. 2nd The tube load increased up to 33%. 3rd Significant dose reduction is achievable without compromising image quality. The use of additional filtration in paediatric fluoroscopy should be evaluated taking into account dose reduction, additional tube loading and the possibility of some deterioration in image quality. (Author)

  1. Surface dose investigation of the flattening filter-free photon beams.

    Science.gov (United States)

    Wang, Yuenan; Khan, Mohammad K; Ting, Joseph Y; Easterling, Stephen B

    2012-06-01

    Flattening filter-free (FFF) x-rays can provide more efficient use of photons and a significant increase of dose rate compared with conventional flattened x-rays, features that are especially beneficial for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). The available data on the entrance doses of the FFF photon beams remain limited. The purpose of this study was to investigate the entrance dose of FFF photons in the buildup region and to compare it with that of conventional flattened photons. A Varian TrueBeam linear accelerator has been in full clinical operation with 6-MV and 10-MV FFF and flattened x-ray photons. Entrance dose at the surface was measured using a parallel plate ionization chamber in a solid water phantom with buildup depth = 0~15 mm for 6X and 0~25 mm for 10X. Different field size (FS) patterns were created in the Eclipse Treatment Planning System by multileaf collimator (MLC) rather than jaws (FS = 2 × 2, 3 × 3, 4 × 4, 6 × 6, and 10 × 10 cm(2) by MLC and jaw size = 2.2 × 2.2, 3.2 × 3.2, 4.2 × 4.2, 6 × 6, and 10 × 10 cm(2)). The smallest FS was about four times larger than the ion chamber dimension. All buildup dose measurements were normalized to FS = 10 × 10 cm(2) at the depth of dose maximum (dmax). Good repeatability was demonstrated and surface dose increased linearly with FS for both flattened and FFF photons. The entrance dose of the FFF photons was modestly larger than that of the corresponding flattened photons for both 6X and 10X for different FS ranging from 2 × 2 cm(2) to 10 × 10 cm(2). The FFF photons have a higher entrance dose than that of the corresponding flattened photons for FS smaller than 10 × 10 cm(2). However, the difference is not substantial and may be clinically insignificant. Published by Elsevier Inc.

  2. Radiation dose and cancer risk to children undergoing skull radiography

    International Nuclear Information System (INIS)

    Mazonakis, Michael; Damilakis, John; Raissaki, Maria; Gourtsoyiannis, Nicholas

    2004-01-01

    Background: Limited data exist in the literature concerning the patient-effective dose from paediatric skull radiography. No information has been provided regarding organ doses, patient dose during PA skull projection, risk of cancer induction and dose to comforters, i.e. individuals supporting children during exposure. Objective: To estimate patient-effective dose, organ doses, lifetime cancer mortality risk to children and radiation dose to comforters associated with skull radiography. Materials and methods: Data were collected from 136 paediatric examinations, including AP, PA and lateral skull radiographs. Entrance-surface dose (ESD) and dose to comforters were measured using thermoluminescent dosimeters. Patients were divided into the following age groups: 0.5-2, 3-7, 8-12 and 13-18 years. The patient-effective dose and corresponding organ doses were calculated using data from the NRPB and Monte Carlo techniques. The risk for fatal cancer induction was assessed using appropriate risk coefficients. Results: For AP, PA and lateral skull radiography, effective dose ranges were 8.8-25.4, 8.2-27.3 and 8.4-22.7 μSv respectively, depending upon the age of the child. For each skull projection, the organs receiving doses above 10 μGy are presented. The number of fatal cancers was found to be less than or equal to 2 per 1 million children undergoing a skull radiograph. The mean radiation dose absorbed by the hands of comforters was 13.4 μGy. Conclusions: The current study provides detailed tabular and graphical data on ESD, effective dose, organ doses and lifetime cancer mortality risk to children associated with AP, PA and lateral skull projections at all patient ages. (orig.)

  3. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  4. Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies

    International Nuclear Information System (INIS)

    Almen, A.J.

    1995-09-01

    A method for estimating mean absorbed dose to different organs and tissues was developed for paediatric patients undergoing X-ray investigations. The absorbed dose distribution in water was measured for the specific X-ray beam used. Clinical images were studied to determine X-ray beam positions and field sizes. Size and position of organs in the patient were estimated using ORNL phantoms and complementary clinical information. Conversion factors between the mean absorbed dose to various organs and entrance surface dose for five different body sizes were calculated. Direct measurements on patients estimating entrance surface dose and energy imparted for common X-ray investigations were performed. The examination technique for a number of paediatric X-ray investigations used in 19 Swedish hospitals was studied. For a simulated pelvis investigation of a 1-year old child the entrance surface dose was measured and image quality was estimated using a contrast-detail phantom. Mean absorbed doses to organs and tissues in urography, lung, pelvis, thoracic spine, lumbar spine and scoliosis investigations was calculated. Calculations of effective dose were supplemented with risk calculations for special organs e g the female breast. The work shows that the examination technique in paediatric radiology is not yet optimised, and that the non-optimised procedures contribute to a considerable variation in radiation dose. In order to optimise paediatric radiology there is a need for more standardised methods in patient dosimetry. It is especially important to relate measured quantities to the size of the patient, using e g the patient weight and length. 91 refs, 17 figs, 8 tabs

  5. Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies

    Energy Technology Data Exchange (ETDEWEB)

    Almen, A J

    1995-09-01

    A method for estimating mean absorbed dose to different organs and tissues was developed for paediatric patients undergoing X-ray investigations. The absorbed dose distribution in water was measured for the specific X-ray beam used. Clinical images were studied to determine X-ray beam positions and field sizes. Size and position of organs in the patient were estimated using ORNL phantoms and complementary clinical information. Conversion factors between the mean absorbed dose to various organs and entrance surface dose for five different body sizes were calculated. Direct measurements on patients estimating entrance surface dose and energy imparted for common X-ray investigations were performed. The examination technique for a number of paediatric X-ray investigations used in 19 Swedish hospitals was studied. For a simulated pelvis investigation of a 1-year old child the entrance surface dose was measured and image quality was estimated using a contrast-detail phantom. Mean absorbed doses to organs and tissues in urography, lung, pelvis, thoracic spine, lumbar spine and scoliosis investigations was calculated. Calculations of effective dose were supplemented with risk calculations for special organs e g the female breast. The work shows that the examination technique in paediatric radiology is not yet optimised, and that the non-optimised procedures contribute to a considerable variation in radiation dose. In order to optimise paediatric radiology there is a need for more standardised methods in patient dosimetry. It is especially important to relate measured quantities to the size of the patient, using e g the patient weight and length. 91 refs, 17 figs, 8 tabs.

  6. Patient dose audit of the most frequent radiographic examinations and the proposed local diagnostic reference levels in southwestern Nigeria: Imperative for dose optimisation

    Directory of Open Access Journals (Sweden)

    N.N. Jibiri

    2016-07-01

    Full Text Available Diagnostic reference levels (DRLs is a veritable tool for dose optimisation and patient protection in diagnostic radiology. However, it is essential to have information on the local situation especially in a large hospital with several units or a cluster of healthcare centres within a geographical region with several X-ray units. In the present study, entrance surface doses (ESDs were measured in twelve (12 healthcare centres consisting of 15 radiological units using thermoluminescent dosimeters (TLDs. Seven radiological procedures such as; chest PA, abdomen AP, pelvis AP, lumbar spine AP, skull AP, knee AP, and hand AP frequently carried out in Nigeria were included in the study, and their local diagnostic reference levels (LDRLs were determined. The values of the determined LDRLs were compared with established NDRLs in UK, US, Slovenia, Italy and Brazil. The LDRLs determined in the two groups (healthcare centres studied ranged from 1.78 to 3.01, 2.71 to 2.84, 2.11 to 3.79, 3.93 to 8.79, 1.06 to 1.73 and 1.10 to 1.44 mGy for chest PA, pelvis AP, lumbar spine AP, skull AP, knee AP and hand AP respectively. Large variations were found among the X-ray units studied even within the same centre. Entrance surface doses obtained in pelvis AP and lumbar spine AP in both GROUP A and were found to be lower than the NRPB-HPA 2010 review for UK, while in all other five examinations, value of the measured entrance surface dose (ESD are higher than the doses reported in the UK review. The relative higher doses found in the study are attributable to higher tube load (mAs used and indicative of the need for dose optimisation in Nigerian radiological practice.

  7. Applied electro-optics educational and training program with multiple entrance and exit pathways

    Science.gov (United States)

    Scott, Patricia; Zhou, Feng; Zilic, Dorothy

    2007-06-01

    This paper presents an innovative hands-on training program designed to create a pipeline of highly-skilled technical workers for today's workforce economy. The 2+2+2 Pennsylvania Integrated Workforce Leadership Program in Electro-Optics prepares students for a career in this new high-tech field. With seamless transition from high school into college, the program offers the versatility of multiple entrance and exit pathways. After completion of each educational level, students can exit the program with various skill levels, including certificates, an associate's degree, or a bachelor's degree. Launched by Indiana University of Pennsylvania (IUP) in partnership with Lenape Vocational School (Lenape), the 2+2+2 educational pathway program was implemented to promote early training of high-school students. During the first level, students in their junior and/or senior year enroll in four Electro-Optics courses at Lenape. Upon completion of these courses and an Advanced Placement Equivalency course with an appropriate exam score, students can earn a certificate from Lenape for the 15+ credits, which also can be articulated into IUP's associate degree program in Electro-Optics. During the second level, students can earn an associate's degree in Electro-Optics, offered only at the IUP Northpointe Campus. After completion of the Associate in Applied Science (A.A.S.), students are prepared to enter the workforce as senior technicians. During the third level, students who have completed the Associate of Science (A.S.) in Electro-Optics have the opportunity to matriculate at IUP's Indiana Campus to earn a Bachelor of Science (B.S.) degree in Applied Physics with a track in Electro-Optics. Hence, the name 2+2+2 refers to getting started in high school, continuing the educational experience with an associate's degree program, and optionally moving on to a bachelor's degree. Consequently, students move from one educational level to the next with advanced credits toward the next

  8. Solar orbiter/PHI full disk telescope entrance window mechanical mount

    Science.gov (United States)

    Barandiaran, J.; Zuluaga, P.; Fernandez, A. B.; Vera, I.; Garranzo, D.; Nuñez, A.; Bastide, L.; Royo, M. T.; Alvarez, A.

    2017-11-01

    PHI is a diffraction limited, wavelength tunable, quasi-monochromatic, and polarization sensitive imager. These capabilities are needed to infer the magnetic field and line-of-sight (LOS) velocity of the region targeted by the spacecraft (spacecraft (S/C)). PHI will consist of two telescopes: The High Resolution Telescope (HRT)[1] and the Full Disk Telescope (FDT). The HRT and the FDT will view the Sun through entrance windows located in the S/C heat shield. These windows act as heat rejecting filters with a transmission band of about 30 nm width centered on the science wavelength, such that the total transmittance (integral over the filter curve weighted with solar spectrum, including white leakage plus transmission profile of the pass band) does not exceed 4% of the total energy falling onto the window [2][3]. The HREW filter has been designed by SELEX in the framework of an ESA led technology development activity under original ESTEC contract No. 20018/06/NL/CP[4], and extensions thereof. For FDT HREW SLEX will provide the windows and it coatings. The HREW consists of two parallel-plane substrate plates (window 1 & window 2)[5] made of SUPRASIL 300 with a central thickness of 9 mm and a wedge of 30 arcsec each. These two substrates are each coated on both sides with four different coatings. These coatings and the choice of SUPRASIL help to minimize the optical absorptivity in the substrate and to radiatively decouple the HREW, which is expected to run at high temperatures during perihelion passages, from the PHI instrument cavity. The temperature distribution of the HREW is driven by two main factors: the mechanical mounting of the substrates to the feedthrough, and the radiative environment within the heat-shield/feedthrough assembly. The mechanical mount must ensure the correct integration of both suprasil substrates in its correct position and minimize the loads in windows due to thermal induced deformations and launching vibration environment. All the

  9. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 3

    International Nuclear Information System (INIS)

    Drexler, G.; Panzer, W.; Widenmann, L.; Williams, G.; Zankl, M.

    1984-03-01

    This report gives tables of conversion factors for the calculation of organ doses from technical parameters of typical radiographic techniques. These conversion factors were calculated using a male and a female mathematical human phantom and an efficient Monte Carlo programme that determines the mean organ doses from the energy deposited in each organ. Each diagnostic X-ray examination is studied using three X-ray spectra resulting from three different high tension values. The conversion factors per unit entrance air dose in free air are given for sixteen organs and for the entrance and exit surface skin doses. The tables are actually valid only for the given parameters such as phantom dimensions, source-to-skin distance, projection and X-ray quality. This, of course, gives rise to some uncertainty when dealing with the individual technique and patient. The uncertainty in organ dose of adult patients, however, should not be very large, if the calculation is based on a similar geometry, and before all, on the actually administered entrance air dose in the selected high tension range according to the patient parameters. (orig.)

  10. Evaluation of organ dose and estimation of risk due to the abdominal region radiography in Indian adults

    International Nuclear Information System (INIS)

    Kumaresan, M.; Chaubey, Ajay; Kantharia, Surita; Karira, V.; Kumar, Rajesh; Biju, K.; Rao, B.S.

    2006-01-01

    Organ dose, risk of carcinogenesis and genetic effect due to the abdominal region radiography in Indian adult with the help of Monte-Carlo MCNP code by measuring the entrance skin dose by LiF: Mg, Cu, P TL phosphor and the risk coefficients provided by ICRP 60 were estimated. The entrance skin dose for abdominal region radiography was ranges from 2.75 mSv to 18.88 mSv while average entrance skin dose was 8.3 mSv. The bladder, testes and ovary are the important organ those are getting higher dose. The maximum dose for testes, ovary and bladder is 5.37 mSv, 1.45 mSv and 4.74 mSv respectively. The frequency of occurrence of fatal cancers and serious genetic disorders as a consequence of abdominal region radiography ranges from 0.1 to 38.8 risk/10 6 of fatal cancer. Although the estimated risks are small but cannot be neglected. It is important to avoid unnecessary repetitions and also to carry out proper quality assurance tests on the equipment and in the long run it will help reduce the risks and maximize the benefits of radiodiagnosis. These studies may lead to setting up of national reference levels for the diagnostic procedures India. (author)

  11. Effect of quality control implementation on image quality of radiographic films and irradiation doses to patients

    International Nuclear Information System (INIS)

    Cheng Yuxi; Zhou Qipu; Ge Lijuan; Hou Changsong; Qi Xuesong; Yue Baorong; Wang Zuoling; Wei Kedao

    1999-01-01

    Objective: To study the changes in the image quality of radiographic films and the irradiation doses to patients after quality control (QC) implementation. Methods: The entrance surface doses (ESD) to patients measured with TLD and the image quality of radiographic films were evaluated on the basis of CEC image quality criteria. Results: The ESD to patients were significantly reduced after QC implementation (P 0.05), but the post-QC image quality was significantly improved in chest PA, lumbar spine AP and pelvis AP(P0.01 or P<0.05). Conclusion: Significantly reduced irradiation dose with improved image quality can be obtained by QC implementation

  12. The establishment and use of dose reference levels in general paediatric radiology

    International Nuclear Information System (INIS)

    Marsden, P.J.; Hardwick, J.; Mencik, C.; McLaren, C.; Young, C.; Mashford, P.

    2001-01-01

    Diagnostic reference levels for general paediatric radiology have been established in terms of delivered exposure parameters rather than skin dose or dose-area product. With supporting measurements from equipment quality assurance and assumptions of standard patient sizes it was possible to derive reference levels in terms of entrance surface dose. This allowed comparison to be made with other published data. The reference levels for common examinations are presented for different age bands. There is a notable variation with patient age for some examinations which is not apparent in other published data. (author)

  13. The Diversity Evaluation Model of the College Entrance Exam and the Implement Countermeasures about Hunan in New Curriculum Based on Secondary School Education Reform

    OpenAIRE

    Peilin Liu; Xiuying Shen; Huabai Bu

    2014-01-01

    The institution of the college entrance exam has been suffered criticisms and it partly reflects its disadvantages. It’s a desiderate problem that thinking about how to develop the institution which needs to be solved quickly by the administrator. The primary topic of this research is that analyze the fundamental theory of the diversity evaluation model and some successful experience happened in foreign countries. In addition, the research analyzes the structure model of the college entrance ...

  14. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  15. Radiation doses in pediatric radiology: influence of regulations and standards

    International Nuclear Information System (INIS)

    Suleiman, O.H.

    2004-01-01

    The benefits of X-ray examinations contribute to the quality of modern medicine; however the risk of using X-rays, a carcinogen, has always been a concern. This concern is heightened for pediatric patients, who have a much greater sensitivity to the carcinogenic effects of radiation than adults. The principle of as low as reasonably achievable, or ALARA, is essential for minimizing the radiation dose patients receive, especially for pediatric patients. In order to keep radiation doses ALARA, one must know the dose patients receive. The determination of radiation dose in a standard way is therefore necessary so that these doses can be compared with practice, and for meaningful comparison against voluntary standards. In extreme situations, where public health needs may require mandatory standards, or regulations, the quantitative measurement and calculation of radiation dose becomes essential. How some radiation dose metrics and standards have evolved, including the value of different metrics such as entrance air kerma, organ dose, and effective dose will be presented. Recent pediatric X-ray studies, whether or not dedicated pediatric equipment is necessary, and recent initiatives by the Food and Drug Administration for pediatric population will be discussed. (orig.)

  16. Radiation doses of patients and urologists during percutaneous nephrolithotomy

    Energy Technology Data Exchange (ETDEWEB)

    Safak, M; Gogus, C [Faculty of Medicine, Ibni Sina Hospital, Department of Urology, Ankara University, 06450 Samanpazari, Ankara (Turkey); Olgar, T; Bor, D; Berkmen, G [Faculty of Engineering, Department of Physics Engineering, Ankara University, 06100, Tandogan, Ankara (Turkey)], E-mail: olgar@eng.ankara.edu.tr

    2009-09-01

    Renal stones can be treated either by extracorporeal shock wave lithotripsy (ESWL) or percutaneous nephrolithotomy (PCNL). Increasing use of fluoroscopic exposure for access and to detect stone location during PCNL make the measurement of patient and staff doses important. The main objective of this work was to assess patient and urologist doses for the PCNL examination. We used the tube output technique for determination of patient doses (n = 20) and lithium fluoride thermoluminescent dosimeter (TLD) chips for urologist dose measurements. The TLD technique was also used for some patient dose measurements (n = 7) for comparison with the tube output technique. Mean entrance skin doses of 191 and 117 mGy were measured by the tube output technique for anterior-posterior (AP) and right anterior oblique (RAO) 30 deg./left anterior oblique (LAO) 30 deg. projections, respectively. The mean urologist doses for eye, finger and collar were measured as 26, 33.5 and 48 {mu}Gy per procedure, respectively. The mean effective dose per procedure for the urologist was 12.7 {mu}Sv. None of the individual skin dose results approach deterministic levels.

  17. Radiation doses of patients and urologists during percutaneous nephrolithotomy

    International Nuclear Information System (INIS)

    Safak, M; Gogus, C; Olgar, T; Bor, D; Berkmen, G

    2009-01-01

    Renal stones can be treated either by extracorporeal shock wave lithotripsy (ESWL) or percutaneous nephrolithotomy (PCNL). Increasing use of fluoroscopic exposure for access and to detect stone location during PCNL make the measurement of patient and staff doses important. The main objective of this work was to assess patient and urologist doses for the PCNL examination. We used the tube output technique for determination of patient doses (n = 20) and lithium fluoride thermoluminescent dosimeter (TLD) chips for urologist dose measurements. The TLD technique was also used for some patient dose measurements (n = 7) for comparison with the tube output technique. Mean entrance skin doses of 191 and 117 mGy were measured by the tube output technique for anterior-posterior (AP) and right anterior oblique (RAO) 30 deg./left anterior oblique (LAO) 30 deg. projections, respectively. The mean urologist doses for eye, finger and collar were measured as 26, 33.5 and 48 μGy per procedure, respectively. The mean effective dose per procedure for the urologist was 12.7 μSv. None of the individual skin dose results approach deterministic levels.

  18. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  19. Calculation of cobalt-60 primary and scatter dose in layered heterogeneous phantoms using primary and scatter dose spread arrays

    International Nuclear Information System (INIS)

    Iwasaki, Akira

    1993-01-01

    A method of making 60 Co γ-ray primary and scatter dose spread arrays in water is described. The primary dose spread array is made using forward and backward primary dose spread equations (h 1 and h 2 ), where both equations contain a laterally spread primary dose equation (G), made from measured dose data in a cork phantom. The scatter dose spread array is made using differential scatter-maximum ratio (dSMR) and differential backscatter factor (dBSF) equations (k 1 and k 2 ), where both equations are made to be continuous on the boundary. Primary and scatter dose calculations are performed along the beam axis in layered cork heterogeneous phantoms. It is found, even for 60 Co γ-rays, that when a small tumor in the lung is irradiated with a field that just surrounds the tumor, the beam entrance surface and lateral side of the tumor may obtain no therapeutic dose, because of loss of longitudinal and lateral electronic equilibrium, and when a large tumor in the lung is irradiated with a field just surrounding the tumor, the lateral side of the tumor may obtain no therapeutic dose due to loss of lateral electronic equilibrium. (author)

  20. Estimation of patient radiation doses during radiologic examinations in the Republic of Haiti

    International Nuclear Information System (INIS)

    Massillon, J.G.; Borras, C.

    2001-01-01

    The International Commission on Radiological Protection and the international organizations that co-sponsored the International Basic Safety Standards for the Protection against Ionization Radiation and for the Safety of Radiation Sources (BSS) - among them PAHO and WHO - recommended the use of investigation levels to provide guidance for medical exposures. In this work, entrance surface doses for several common diagnostic radiology procedure have been determined from exposure rate measurements and patient technique factors in seven 'World Health Imaging System - Radiography' (WHIS-RAD) units, installed in public health services facilities of the Republic of Haiti. The results show the entrance surface doses below the guidance levels published in the BSS. Concomitant image quality measurements performed, however, indicate serious artifacts in the film processing, calling for the need of additional training of the technologists. (author)

  1. Patient and staff doses from digital Bi-plane coronary angiography

    International Nuclear Information System (INIS)

    Janeczek, J.; James, D.; Beal, A.

    2000-01-01

    Coronary angiography is the standard technique for imaging the left ventricle and coronary arteries and is a high radiation dose procedure. The number of these procedures has significantly increased in recent years with a resultant increase in radiation dose to staff and patients. When the new Philips Bi-plane BV-5000 digital angiography unit was installed in Tawam Hospital the assessment of staff and patient doses was undertaken as a part of ongoing program of quality assurance. In this study we examine the technique at Tawam Hospital to determine current practice and measure radiation dose to patient and staff resulting from coronary angiography examinations. Two sets of measurements were conducted: scattered radiation distribution around the unit and patient equivalent dose with additional entrance dose from LAT and AP fields. Prior to the measurements analysis of 10 cardiac procedures involving patients of average size (70-80 kg) was performed and their radiographic parameters recorded and averaged. Dose area product DAP were recorded during these procedures and were used as a reference in both measurements. TLD-100 and TLD-MCP were used for scatter radiation measurements. The former were positioned close to the patient and the latter (due to their higher sensitivity) further away. For patient entrance dose assessment TLD-100 were used. TLD chips were arranged in a 3-D structure positioned close to the patient to measure the scattered dose distribution at the place where the cardiologist, assistant cardiologist and nurse would stand. The other TLDs were placed on thin plastic poles 100 cm from the floor in the areas of interest. Dosimeters were calibrated in terms of absorbed dose to air and soft tissue. TLDs were placed positions and the cardiac procedure was recreated using a Rando Alderson phantom to simulate patient of average size. The mean total DAP calculated from the measurements recorded during 10 patient examinations was 11.8 Gy cm 2 . Using a

  2. Trend of patient radiation doses in medical examination in Japan

    International Nuclear Information System (INIS)

    Suzuki, Shoichi

    2013-01-01

    We have investigated radiation doses to patients in selected types of examinations in Japan since 1974 and have analyzed the trend of patient radiation doses during a period of 37 years. This study covered regular plain X-ray scanning (including mammography) and computed tomography (CT) scanning. Dose evaluation was performed in terms of entrance skin dose (ESD) for regular plain X-ray scanning, average glandular dose (AGD) for mammography, and volume CT dose index (CTDIvol) for CT scanning. Evaluation was performed in 26 orientations at 21 sites for regular plain X-rays, and for cranial, thoracic, and abdominal scans of children and adults for CT scanning. With the exception of chest X-rays, the dose during regular plain X-ray scanning had decreased by approximately 50% compared with scans performed in 1974. The dose during mammography had decreased to less than 10% of its former level. In scans performed in 2011, dose at all sites were within International Atomic Energy Authority (IAEA) guidance levels. The increasing use of multiple detectors in CT scanning devices was evident in CT scanning. A comparison of doses from cranial non-helical scans performed in 2007 and 2011 found that the latter were higher. An examination of changes in doses between 1997 and 2011 revealed that doses had tended to increase in cranial scans of adults, but had hardly changed at all in abdominal scans. Doses during CT scanning of children were around half those for adults in cranial, thoracic, and abdominal scans. We have ascertained changes in the doses to which patients have been exposed during X-ray scanning in Japan. (author)

  3. Radiation Dose from Voiding Cystourethrography (VCUG) Examination in Children

    International Nuclear Information System (INIS)

    Siriwiladluk, T.; Krisanachinda, A.

    2012-01-01

    Introduction: The purpose of this study is to determine entrance skin dose (ESD) from fluoroscopy and radiography procedures in voiding cystourethrography (VCUG) studies of pediatric patients by dose-area product (DAP) recording. Methods: Radiation doses received by 70 patients underwent VCUG procedures were determined by the DAP Meter, Wellh?fer Dosimetrie GmbH, Germany) directly coupled to the x-ray tube window (Philips Omni Diagnost Eleva) and an electrometer connected to a computer for data collection. The study revealed the radiation dose for VCUG and the baseline data on the entrance skin dose, ESD, dose area-product (DAP) and the effective dose, E, to establish local reference dose levels for VCUG in pediatric patients. Results: The mean(minimum-maximum) ESD, DAP and the effective dose of pediatric patients in 4 age ranges were 3.41(1-9) mGy, 46.58 (21.90-158.90) cGycm 2 and 0.10(0.05-0.33) mSv for 0- 1 years, 6.80(2-16) mGy, 115.55 (20.70-258.70)cGycm 2 and 0.24(0.04-0.54) mSv for >1-5 years, 11.76 (3-23) mGy, 292.28 (88.90-593.50)cGycm 2 and 0.61(0.19-1.25) mSv for >5-10 years, and 20.50(10-42) mGy, 575.98(255.60-1247.80) cGycm 2 and 1.12(0.54-2.62) mSv for >10-15 years respectively. Discussion: The dose levels for VCUG as recommended by the national reference doses (NRDs) of UK are classified at patient age of 0-1 years, 90 cGy.cm 2 , >1-5 years, 110 cGy.cm 2 , >5-10 years, 210 cGy.cm 2 and >10-15 years, 470 cGy.cm 2 respectively. Conclusions: The mean DAP of pediatric patients were higher than the dose level as recommended by NRD at the age range >1-5, >5-10 and >10-15 years. The limitation in this study was the non uniform in the number of patients at the higher age. Attempts could be made to lower the radiation dose to avoid the higher risk of developing radiation-induced cancer in children. (author)

  4. Measurement of patient radiation doses in certain urography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Zailae, A.; Abuderman, A.; Theodorou, K.

    2015-01-01

    Patients are exposed to significant radiation doses during diagnostic and interventional urological procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethrogram (ASU) procedures. ESAK was measured in patients using calibrated thermo luminance dosimeters, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 179 procedures were investigated. 27.9 % of the patients underwent IVU procedures, 27.9 % underwent ESWL procedures and 44.2 % underwent ASU procedures. The mean ESAK was 2.1, 4.18 and 4.9 mGy for IVU, ESWL, and ASU procedures, respectively. Differences in patient ESAK for the same procedure were observed. The mean ESAK values were comparable with those in previous studies. (authors)

  5. Identification of genes associated with growth cessation and bud dormancy entrance using a dormancy-incapable tree mutant.

    Science.gov (United States)

    Jiménez, Sergio; Li, Zhigang; Reighard, Gregory L; Bielenberg, Douglas G

    2010-02-09

    In many tree species the perception of short days (SD) can trigger growth cessation, dormancy entrance, and the establishment of a chilling requirement for bud break. The molecular mechanisms connecting photoperiod perception, growth cessation and dormancy entrance in perennials are not clearly understood. The peach [Prunus persica (L.) Batsch] evergrowing (evg) mutant fails to cease growth and therefore cannot enter dormancy under SD. We used the evg mutant to filter gene expression associated with growth cessation after exposure to SD. Wild-type and evg plants were grown under controlled conditions of long days (16 h/8 h) followed by transfer to SD (8 h/16 h) for eight weeks. Apical tissues were sampled at zero, one, two, four, and eight weeks of SD and suppression subtractive hybridization was performed between genotypes at the same time points. We identified 23 up-regulated genes in the wild-type with respect to the mutant during SD exposure. We used quantitative real-time PCR to verify the expression of the differentially expressed genes in wild-type tissues following the transition to SD treatment. Three general expression patterns were evident: one group of genes decreased at the time of growth cessation (after 2 weeks in SD), another that increased immediately after the SD exposure and then remained steady, and another that increased throughout SD exposure. The use of the dormancy-incapable mutant evg has allowed us to reduce the number of genes typically detected by differential display techniques for SD experiments. These genes are candidates for involvement in the signalling pathway leading from photoperiod perception to growth cessation and dormancy entrance and will be the target of future investigations.

  6. Assessment of exit block following pulmonary vein isolation: far-field capture masquerading as entrance without exit block.

    Science.gov (United States)

    Vijayaraman, Pugazhendhi; Dandamudi, Gopi; Naperkowski, Angela; Oren, Jess; Storm, Randle; Ellenbogen, Kenneth A

    2012-10-01

    Complete electrical isolation of pulmonary veins (PVs) remains the cornerstone of ablation therapy for atrial fibrillation. Entrance block without exit block has been reported to occur in 40% of the patients. Far-field capture (FFC) can occur during pacing from the superior PVs to assess exit block, and this may appear as persistent conduction from PV to left atrium (LA). To facilitate accurate assessment of exit block. Twenty consecutive patients with symptomatic atrial fibrillation referred for ablation were included in the study. Once PV isolation (entrance block) was confirmed, pacing from all the bipoles on the Lasso catheter was used to assess exit block by using a pacing stimulus of 10 mA at 2 ms. Evidence for PV capture without conduction to LA was necessary to prove exit block. If conduction to LA was noticed, pacing output was decreased until there was PV capture without conduction to LA or no PV capture was noted to assess for far-field capture in both the upper PVs. All 20 patients underwent successful isolation (entrance block) of all 76 (4 left common PV) veins: mean age 58 ± 9 years; paroxysmal atrial fibrillation 40%; hypertension 70%, diabetes mellitus 30%, coronary artery disease 15%; left ventricular ejection fraction 55% ± 10%; LA size 42 ± 11 mm. Despite entrance block, exit block was absent in only 16% of the PVs, suggesting persistent PV to LA conduction. FFC of LA appendage was noted in 38% of the left superior PVs. FFC of the superior vena cava was noted in 30% of the right superior PVs. The mean pacing threshold for FFC was 7 ± 4 mA. Decreasing pacing output until only PV capture (loss of FFC) is noted was essential to confirm true exit block. FFC of LA appendage or superior vena cava can masquerade as persistent PV to LA conduction. A careful assessment for PV capture at decreasing pacing output is essential to exclude FFC. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  7. PA positioning significantly reduces testicular dose during sacroiliac joint radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mekis, Nejc [Faculty of Health Sciences, University of Ljubljana (Slovenia); Mc Entee, Mark F., E-mail: mark.mcentee@ucd.i [School of Medicine and Medical Science, University College Dublin 4 (Ireland); Stegnar, Peter [Jozef Stefan International Postgraduate School, Ljubljana (Slovenia)

    2010-11-15

    Radiation dose to the testes in the antero-posterior (AP) and postero-anterior (PA) projection of the sacroiliac joint (SIJ) was measured with and without a scrotal shield. Entrance surface dose, the dose received by the testicles and the dose area product (DAP) was used. DAP measurements revealed the dose received by the phantom in the PA position is 12.6% lower than the AP (p {<=} 0.009) with no statistically significant reduction in image quality (p {<=} 0.483). The dose received by the testes in the PA projection in SIJ imaging is 93.1% lower than the AP projection when not using protection (p {<=} 0.020) and 94.9% lower with protection (p {<=} 0.019). The dose received by the testicles was not changed by the use of a scrotal shield in the AP position (p {<=} 0.559); but was lowered by its use in the PA (p {<=} 0.058). Use of the PA projection in SIJ imaging significantly lowers, the dose received by the testes compared to the AP projection without significant loss of image quality.

  8. Effective dose estimation to patients and staff during urethrography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Alkhorayef, M.; Babikir, E.; Dalton, A.; Bradley, D.

    2015-10-01

    Medical-related radiation is the largest source of controllable radiation exposure to humans and it accounts for more than 95% of radiation exposure from man-made sources. Few data were available worldwide regarding patient and staff dose during urological ascending urethrography (ASU) procedure. The purposes of this study are to measure patient and staff entrance surface air kerma dose (ESAK) during ASU procedure and evaluate the effective doses. A total of 243 patients and 145 staff (Urologist) were examined in three Hospitals in Khartoum state. ESAKs were measured for patient and staff using thermoluminescent detectors (TLDs). Effective doses (E) were calculated using published conversion factors and methods recommended by the national Radiological Protection Board (NRPB). The mean ESAK dose for patients and staff dose were 7.79±6.7 mGy and 0.161±0.30 mGy per procedures respectively. The mean and range of the effective dose was 1.21 mSv per procedure. The radiation dose in this study is comparable with previous studies except Hospital C. It is obvious that high patient and staff exposure is due to the lack of experience and protective equipment s. Interventional procedures remain operator dependent; therefore continuous training is crucial. (Author)

  9. PA positioning significantly reduces testicular dose during sacroiliac joint radiography

    International Nuclear Information System (INIS)

    Mekis, Nejc; Mc Entee, Mark F.; Stegnar, Peter

    2010-01-01

    Radiation dose to the testes in the antero-posterior (AP) and postero-anterior (PA) projection of the sacroiliac joint (SIJ) was measured with and without a scrotal shield. Entrance surface dose, the dose received by the testicles and the dose area product (DAP) was used. DAP measurements revealed the dose received by the phantom in the PA position is 12.6% lower than the AP (p ≤ 0.009) with no statistically significant reduction in image quality (p ≤ 0.483). The dose received by the testes in the PA projection in SIJ imaging is 93.1% lower than the AP projection when not using protection (p ≤ 0.020) and 94.9% lower with protection (p ≤ 0.019). The dose received by the testicles was not changed by the use of a scrotal shield in the AP position (p ≤ 0.559); but was lowered by its use in the PA (p ≤ 0.058). Use of the PA projection in SIJ imaging significantly lowers, the dose received by the testes compared to the AP projection without significant loss of image quality.

  10. Effective dose estimation to patients and staff during urethrography procedures

    Energy Technology Data Exchange (ETDEWEB)

    Sulieman, A. [Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O- Box 422, Alkharj 11942 (Saudi Arabia); Barakat, H. [Neelain University, College of Science and Technology, Medical Physics Department, Khartoum (Sudan); Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Dalton, A.; Bradley, D. [University of Surrey, Centre for Nuclear and Radiation Physics, Department of Physics, Surrey, GU2 7XH Guildford (United Kingdom)

    2015-10-15

    Medical-related radiation is the largest source of controllable radiation exposure to humans and it accounts for more than 95% of radiation exposure from man-made sources. Few data were available worldwide regarding patient and staff dose during urological ascending urethrography (ASU) procedure. The purposes of this study are to measure patient and staff entrance surface air kerma dose (ESAK) during ASU procedure and evaluate the effective doses. A total of 243 patients and 145 staff (Urologist) were examined in three Hospitals in Khartoum state. ESAKs were measured for patient and staff using thermoluminescent detectors (TLDs). Effective doses (E) were calculated using published conversion factors and methods recommended by the national Radiological Protection Board (NRPB). The mean ESAK dose for patients and staff dose were 7.79±6.7 mGy and 0.161±0.30 mGy per procedures respectively. The mean and range of the effective dose was 1.21 mSv per procedure. The radiation dose in this study is comparable with previous studies except Hospital C. It is obvious that high patient and staff exposure is due to the lack of experience and protective equipment s. Interventional procedures remain operator dependent; therefore continuous training is crucial. (Author)

  11. Comparison of programmed and cabled re-entrance systems. Elaboration of cabled re-entrance system for a CII 90.40; Comparaison des systemes de reentrance programmes et cables. Realisation d'un systeme de reentrance cable pour un CII 90.40

    Energy Technology Data Exchange (ETDEWEB)

    Perraudeau, Jean

    1976-11-26

    The objective of this research thesis is to study problems related to re-entrance, and, more particularly, to study a re-entrance system for a CII 90.40 computer. Such a system can be realised under a programmed or cabled form, and both approaches are described and compared. A generalisation of this comparison is briefly proposed. As the computer already possesses a programmed re-entrance system, the author focuses on the study of the cabled re-entrance system which results in an improvement of performance and possibilities provided by this computer, particularly for its use in real time. The design, realisation and development of such a cabled system are reported. A first part reports a theoretical study on re-entrance (definition, problems, applications), a presentation of the computer, a description of the programmed re-entrance system, a presentation of the principle of the chosen cabled re-entrance system, a definition of the structure and operating mode of the cabled pile and a description of its various components, and a flowchart analysis of function execution. The second part reports the practical realisation: definition, technological overview, technology used in the cabled pile, sequencing and multiplexing principle, impulse transmission, logical layouts, and circuit adjustments. The third part presents practical example. An assessment and perspectives are finally discussed.

  12. The study of mean glandular dose in mammography in Yazd and the factors affecting it

    International Nuclear Information System (INIS)

    Bouzarjomehri, F.; Mostaar, A.; Ghasemi, A.; Ehramposh, M. H.; Khosravi, H.

    2006-01-01

    The objective of this study was to determine the mean glandular dose resulting from mammography examinations in Yazd, southeastern Iran and to identify the factors affecting it. Patients and Methods: This survey was conducted during May to December 2005 to estimate the mean glandular dose for women undergoing mammography and to report the distribution of dose. compressed breast thickness, glandular tissue content, and mammography technique used. The clinical data were collected from 946 mammograms taken from 246 women who were referred to four mammography centers. The mammography instruments in these centers were four modern units with a molybdenum anode and either molybdenum or rhodium filter. The exposure conditions of each mammogram were recorded. The breast glandular content of each mammogram was estimated by a radiologist. The mean glandular dose was calculated based on measuring the normalized entrance skin dose in air. half value layer, kVp, mAs, breast thickness and glandular content. Half value layer, kVp and entrance skin dose were measured by a solid-state detector. The analytical method of Sobol et al. was used for calculation of mean glandular dose . Results: The mean±SD mean glandular dose per film was.2±0.6 mGy for cranio caudal and 1.63±O.9 mGy for mediolateral oblique views. The mean±SD mean glandular dose per woman was 5.5 3.1.mGy. A positive correlation was found between the beam Half value layer with mean glandular dose (r=O.38) and the breast thickness with mean glandular dose (r=O.5). Conclusion: The mean±SD mean glandular dose per film of 1.42±0.8 mGy in present study was lower than most of similar reports. However, the mean mean glandular dose per woman was higher than that in other studies

  13. Assessment of dose in cervical vertebrae radiographic examinations

    International Nuclear Information System (INIS)

    Owrnasir, Wafa Fadol Orsud

    2014-12-01

    Reference dose levels provide a framework to reduce doses variability and aid in the optimization of radiation protection.This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study performed to assess the entrance surface dose ( ESD) received in Cervical Vertebrae radiographic examination and to analyze effective dose distributions among radiological departments under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 64 patients. The following parameter were recorded; age, weight, height, body mass index (BMI) derived from weight (kg) and height (m) and exposure factors. The dose was measured for Cervical Vertebrae x-ray examinations, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for Cervical Vertebrae AP and lateral examinations. The ESD values were then calculated using IAEA calculation methods. The results of ESD values calculated showed than patient exposure were within the normal range of exposure. The mean ED values calculated were ( 3.85 ±0.04) and (4.02 ±0.05) mGy for Cervical Vertebrae AP and lateral examinations, respectively in department Na1 and (3.99± 0.15) and (4.23± 0.34) mGy, for Cervical Vertebrae Ap and lateral examinations respectively in department Na2, the IAEA standard value of ESD for cervical equal (7), (20) mGy AP and LAT, Further studies are recommended with more number of patients and using more than two modalities for comparison. (Author)

  14. Radiation Dose to Newborns in Neonatal Intensive Care Units

    International Nuclear Information System (INIS)

    Bahreyni Toossi, M. T.; Malekzadeh, M.

    2012-01-01

    With the increase of X-ray use for medical diagnostic purposes, knowing the given doses is necessary in patients for comparison with reference levels. The concept of reference doses or diagnostic reference levels has been developed as a practical aid in the optimization of patient protection in diagnostic radiology. To assess the radiation doses to neonates from diagnostic radiography (chest and abdomen). This study has been carried out in the neonatal intensive care unit of a province in Iran. Entrance surface dose was measured directly with thermoluminescent dosimeters. The population included 195 neonates admitted for a diagnostic radiography, in eight NICUs of different hospital types. The mean entrance surface dose for chest and abdomen examinations were 76.3 μGy and 61.5 μGy, respectively. Diagnostic reference levels for neonate in NICUs of the province were 88 μGy for chest and 98 μGy for abdomen examinations that were slightly higher than other studies. Risk of death due to radiation cancer incidence of abdomens examination was equal to 1.88 × 10 -6 for male and 4.43 × 10 -6 for female. For chest X-ray, it was equal to 2.54 × 10 -6 for male and 1.17 × 10 -5 for female patients. Diagnostic reference levels for neonates in our province were slightly higher than values reported by other studies such as European national diagnostic reference levels and the NRPB reference dose. The main reason was related to using a high mAs and a low kVp applied in most departments and also a low focus film distance. Probably lack of collimation also affected some exams in the NICUs.

  15. Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry

    International Nuclear Information System (INIS)

    Nascimento, Cristina R.; Asfora, Viviane K.; Barros, Vinicius S.M.; Gonçalves, Josemary A.C.; Andrade, Lucas F.R.; Khoury, Helen J.; Bueno, Carmen C.

    2017-01-01

    The response of the commercial XRA-24 PIN photodiode (5.76 mm 2 active area) for clinical electron beam dosimetry covering the range of 8-12 MeV was investigated. Within this energy range, the charge generated in the diode's sensitive volume is linearly dependent on the absorbed dose up to 320 cGy. However, charge sensitivity coefficients evidenced that the dose response of the diode is slightly dependent on the electron beam energy. Indeed, the diode's energy dependence was within 8.5% for 8-12MeV electron beams. On the other hand, it was also observed an excellent repeatability of these results with a variation coefficient (VC) lower than 0.4%, which is within the 1% tolerance limit recommended by the AAPM TG-62. Furthermore, the agreement between the percentage depth dose profiles (PDD) gathered with the diode and the ionization chamber allowed achieving the electron beam quality within 1% of that obtained with the ionization chamber. Based on these results, the photodiode XRA-24 can be a reliable and inexpensive alternative for electron beams dosimetry. (author)

  16. Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento, Cristina R.; Asfora, Viviane K.; Barros, Vinicius S.M.; Gonçalves, Josemary A.C.; Andrade, Lucas F.R.; Khoury, Helen J.; Bueno, Carmen C., E-mail: vsmdbarros@gmail.com, E-mail: vikhoury@gmail.com, E-mail: hjkhoury@gmail.com, E-mail: cristinaramos@smartsat.com.br, E-mail: josemary@ipen.br, E-mail: ccbueno@ipen.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Instituto Federal de Educação, Ciência e Tecnologia de Pernambuco (IFPE), Recife-PE (Brazil). Departamento de Energia Nuclear; Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Santa Casa de Misericórdia de Itabuna, BA (Brazil)

    2017-11-01

    The response of the commercial XRA-24 PIN photodiode (5.76 mm{sup 2} active area) for clinical electron beam dosimetry covering the range of 8-12 MeV was investigated. Within this energy range, the charge generated in the diode's sensitive volume is linearly dependent on the absorbed dose up to 320 cGy. However, charge sensitivity coefficients evidenced that the dose response of the diode is slightly dependent on the electron beam energy. Indeed, the diode's energy dependence was within 8.5% for 8-12MeV electron beams. On the other hand, it was also observed an excellent repeatability of these results with a variation coefficient (VC) lower than 0.4%, which is within the 1% tolerance limit recommended by the AAPM TG-62. Furthermore, the agreement between the percentage depth dose profiles (PDD) gathered with the diode and the ionization chamber allowed achieving the electron beam quality within 1% of that obtained with the ionization chamber. Based on these results, the photodiode XRA-24 can be a reliable and inexpensive alternative for electron beams dosimetry. (author)

  17. Absorbed dose to the patient by computerized whole body X-ray tomography

    International Nuclear Information System (INIS)

    Krauss, O.; Schuhmacher, H.

    1977-01-01

    The absorbed dose to the patient was measured for several medical investigations by computerized whole body scanning. An Alderson-phantom mounted with LiF-TLD was irradiated with a Delta-Scan (Ohio-Nuclear, 120 kV, 30 mA). The integral dose to the brain during a full examination (6 scans, filtration 3 mm Al) was measured to 5x10 -2 J. The maximum absorbed dose at the entrance was found to be 3.2 rd and at the exit 0.6 rd. The dose to the eyes is 0.7 rd and to the thyroid gland 0.03 rd. The integral dose to the trunk (5 scans in the region of liver and kidneys, filtration 6 mm Al) was measured to 5x10 -2 J. The maximum absorbed dose at the entrance was found to be 2.4 rd and at the exit 0.25 rd. The dose to the gonads is less than 2 and 4 mrd if the distance between the last scan and the gonads is more than 15 cm

  18. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  19. Studies of absorbed dose determinations and spatial dose distributions for high energy proton beams

    International Nuclear Information System (INIS)

    Hiraoka, Takeshi

    1982-01-01

    Absolute dose determinations were made with three types of ionization chamber and a Faraday cup. Methane based tissue equivalent (TE) gas, nitrogen, carbon dioxide, air were used as an ionizing gas with flow rate of 10 ml per minute. Measurements were made at the entrance position of unmodulated beams and for a beam of a spread out Bragg peak at a depth of 17.3 mm in water. For both positions, the mean value of dose determined by the ionization chambers was 0.993 +- 0.014 cGy for which the value of TE gas was taken as unity. The agreement between the doses estimated by the ionization chambers and the Faraday cup was within 5%. Total uncertainty estimated in the ionization chamber and the Faraday cup determinations is 6 and 4%, respectively. Common sources of error in calculating the dose from ionization chamber measurements are depend on the factors of ion recombination, W value, and mass stopping power ratio. These factors were studied by both experimentally and theoretically. The observed values for the factors show a good agreement to the predicted one. Proton beam dosimetry intercomparison between Japan and the United States was held. Good agreement was obtained with standard deviation of 1.6%. The value of the TE calorimeter is close to the mean value of all. In the proton spot scanning system, lateral dose distributions at any depth for one spot beam can be simulated by the Gaussian distribution. From the Gaussian distributions and the central axis depth doses for one spot beam, it is easy to calculate isodose distributions in the desired field by superposition of dose distribution for one spot beam. Calculated and observed isodose curves were agreed within 1 mm at any dose levels. (J.P.N.)

  20. Correlation between scatter radiation dose at the height of the operators eye and dose to patient for different angiographies projections

    Energy Technology Data Exchange (ETDEWEB)

    Leyton, F.; Nogueira, M. S.; Da Silva, T. A. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Post-graduation in Sciences and Technology of Radiations, Minerals and Materials, Pte. Antonio Carlos No. 6627, Belo Horizonte 31270-901, Minas Gerais (Brazil); Gubolino, L.; Pivetta, M. R. [Hospital dos Fornecedores de Cana de Piracicaba, Av. Barao de Valenca 616, 13405-233 Piracicaba (Brazil); Ubeda, C., E-mail: leyton.fernando@gmail.com [Tarapaca University, Health Sciences Faculty, Radiological Sciences Center, Av. Gral. Velasquez 1775, 1000007 Arica, Arica and Parinacota (Chile)

    2015-10-15

    Cases of radiation induced cataract among cardiology professionals have been reported in studies. In view of evidence of radiation injuries, the ICRP recommends limiting the radiation dose to the lens to 20 mSv per year for occupational exposure. The aim of this works was to report scattered radiation doses at the height of the operators eye in an interventional cardiology facility from procedures performed without use of radiation protection devices, correlated with different angiographic projections and operational modes. Measurements were made in a cardiac laboratory with an angiography X-ray system GE equipped with flat-panel detector. PMMA plates of 30 x 30 x 5 cm were used to simulate a patient with a thickness of 20 cm. Two fluoroscopy modes (low and normal, 15 frame/s), cine mode 15 frame/s. Four angiographic projections anterior posterior (Ap), lateral (Lat), left anterior oblique caudal (spider) and left anterior oblique cranial (Lao-45/cra-30) and a cardiac protocol for patient between 70 to 90 kg was used. Measurements of phantom entrance doses rate and scatter doses rate were performed with two Unfors Xi plus. The detector measuring scatter radiation was positioned at the usual distance of the cardiologists eyes during working conditions (1 m from the isocenter and 1.7 m from the floor). There is a good linear correlation between the kerma-area product and scatter dose at the lens. An experimental correlation factor of 2.3; 12.0; 12.2 and 17.6 μSv/Gy cm{sup 2} were found for the Ap, Lao/cra, spider and Lat projections, respectively. The entrance dose of PMMA for fluoroscopy low, medium and cine was 13, 39 and 282 mGy/min, respectively to Ap. (Author)

  1. Correlation between scatter radiation dose at the height of the operators eye and dose to patient for different angiographies projections

    International Nuclear Information System (INIS)

    Leyton, F.; Nogueira, M. S.; Da Silva, T. A.; Gubolino, L.; Pivetta, M. R.; Ubeda, C.

    2015-10-01

    Cases of radiation induced cataract among cardiology professionals have been reported in studies. In view of evidence of radiation injuries, the ICRP recommends limiting the radiation dose to the lens to 20 mSv per year for occupational exposure. The aim of this works was to report scattered radiation doses at the height of the operators eye in an interventional cardiology facility from procedures performed without use of radiation protection devices, correlated with different angiographic projections and operational modes. Measurements were made in a cardiac laboratory with an angiography X-ray system GE equipped with flat-panel detector. PMMA plates of 30 x 30 x 5 cm were used to simulate a patient with a thickness of 20 cm. Two fluoroscopy modes (low and normal, 15 frame/s), cine mode 15 frame/s. Four angiographic projections anterior posterior (Ap), lateral (Lat), left anterior oblique caudal (spider) and left anterior oblique cranial (Lao-45/cra-30) and a cardiac protocol for patient between 70 to 90 kg was used. Measurements of phantom entrance doses rate and scatter doses rate were performed with two Unfors Xi plus. The detector measuring scatter radiation was positioned at the usual distance of the cardiologists eyes during working conditions (1 m from the isocenter and 1.7 m from the floor). There is a good linear correlation between the kerma-area product and scatter dose at the lens. An experimental correlation factor of 2.3; 12.0; 12.2 and 17.6 μSv/Gy cm 2 were found for the Ap, Lao/cra, spider and Lat projections, respectively. The entrance dose of PMMA for fluoroscopy low, medium and cine was 13, 39 and 282 mGy/min, respectively to Ap. (Author)

  2. New model for mines and transportation tunnels external dose calculation using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Allam, Kh. A.

    2017-01-01

    In this work, a new methodology is developed based on Monte Carlo simulation for tunnels and mines external dose calculation. Tunnels external dose evaluation model of a cylindrical shape of finite thickness with an entrance and with or without exit. A photon transportation model was applied for exposure dose calculations. A new software based on Monte Carlo solution was designed and programmed using Delphi programming language. The variation of external dose due to radioactive nuclei in a mine tunnel and the corresponding experimental data lies in the range 7.3 19.9%. The variation of specific external dose rate with position in, tunnel building material density and composition were studied. The given new model has more flexible for real external dose in any cylindrical tunnel structure calculations. (authors)

  3. Perturbation of cobalt 60 radiation doses by metal objects implanted during oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Tatcher, M.; Kuten, A.; Helman, J.; Laufer, D.

    1984-01-01

    The influence on cobalt 60 dose distributions of typical metal parts used in oral and maxillofacial surgery was studied. Relative doses were determined by exposing x-ray films in a polystyrene phantom set-up containing samples of vitallium, titanium, and stainless steel. Optical densities were converted to doses with the aid of sensitometric curves. The results show that for normal incidence there is a 25% to 40% increase in dose at the entrance side of the metal and a 20% to 25% decrease in dose at the exit side. The enhancement effect falls off rapidly and becomes negligible at about 1 mm from the interface. The reduction effect decreases more gradually and is still evident at distances of a few centimeters. These dose perturbations should be taken into account in the planning of radiation therapy for patients in whom metal objects have been implanted

  4. A two-stage compound parabolic concentrator system with a large entrance over the exit aperture ratio

    International Nuclear Information System (INIS)

    Angelescu, Tatiana; Radu, A. A.

    2000-01-01

    Certain optical designs in the field of high energy gamma ray astronomy components of the Cherenkov light, collected by the mirror of telescope, be concentrated on the photo-cathodes of the photomultiplier tubes, with the help of the light collectors having large entrance and small exit apertures. Mathematical restrictions imposed by the design of the compound parabolic concentrator (CPC) implied that for a given cut-off angle and an entrance aperture, the exit aperture of the CPC should not exceed a limit value. If this value is larger than the active diameter of the photocathode, an additional concentrator must be added to the system in order to transfer the light collected, from the exit aperture of the compound parabolic concentrator to the photocathode of the photomultiplier tube. Different designs of a two-stage system composed by a a hollow compound parabolic concentrator and a solid, dielectric filled concentrator are evaluated in this paper, from the point of view of optical efficiency and manufacturability. (authors)

  5. Design of twisted tape turbulator at different entrance angle for heat transfer enhancement in a solar heater

    Directory of Open Access Journals (Sweden)

    Suvanjan Bhattacharyya

    2018-03-01

    Full Text Available Numerical investigation of heat transfer characteristics in a tube fitted with inserted twisted tape swirl generator is performed. The twisted tapes are separately inserted from the tube wall. The configuration parameters include the, entrance angle (α and pitch (H. Investigations have been done in the range of α = 180°, 160° and 140° with Reynolds number varying between 100 and 20,000. In this paper, transition – SST model which can predict the transition of flow regime from laminar through intermittent to turbulent has been utilized for numerical simulations. The computational results are in good agreement with experimental data. The results show that higher entrance angle yields a higher heat transfer value. The using of single twist twisted tape supplies considerable increase on heat transfer and pressure drop when compared with the conventional twisted tapes. A large data set has been generated for heat transfer and thermal-hydraulic performance which is useful for the design of solar thermal heaters and heat exchangers.

  6. A Two-Stage DEA to Analyze the Effect of Entrance Deregulation on Iranian Insurers: A Robust Approach

    Directory of Open Access Journals (Sweden)

    Seyed Gholamreza Jalali Naini

    2012-01-01

    Full Text Available We use two-stage data envelopment analysis (DEA model to analyze the effects of entrance deregulation on the efficiency in the Iranian insurance market. In the first stage, we propose a robust optimization approach in order to overcome the sensitivity of DEA results to any uncertainty in the output parameters. Hence, the efficiency of each ongoing insurer is estimated using our proposed robust DEA model. The insurers are then ranked based on their relative efficiency scores for an eight-year period from 2003 to 2010. In the second stage, a comprehensive statistical analysis using generalized estimating equations (GEE is conducted to analyze some other factors which could possibly affect the efficiency scores. The first results from DEA model indicate a decline in efficiency over the entrance deregulation period while further statistical analysis confirms that the solvency ignorance which is a widespread paradigm among state owned companies is one of the main drivers of efficiency in the Iranian insurance market.

  7. A Study of the Location of the Entrance of a Fishway in a Regulated River with CFD and ADCP

    Directory of Open Access Journals (Sweden)

    Anders G. Andersson

    2012-01-01

    Full Text Available Simulation-driven design with computational fluid dynamics has been used to evaluate the flow downstream of a hydropower plant with regards to upstream migrating fish. Field measurements with an Acoustic Doppler Current Profiler were performed, and the measurements were used to validate the simulations. The measurements indicate a more unstable flow than the simulations, and the tailrace jet from the turbines is stronger in the simulations. A fishway entrance was included in the simulations, and the subsequent attraction water was evaluated for two positions and two angles of the entrance at different turbine discharges. Results show that both positions are viable and that a position where the flow from the fishway does not have to compete with the flow from the power plant will generate superior attraction water. Simulations were also performed for further downstream where the flow from the turbines meets the old river bed which is the current fish passage for upstream migrating fish. A modification of the old river bed was made in the model as one scenario to generate better attraction water. This considerably increases the attraction water although it cannot compete with the flow from the tailrace tunnel.

  8. Implementation of 'early alert system' area detector at patient from entrance in afterloading brachytherapy

    International Nuclear Information System (INIS)

    Videla Valdebenito, R.

    2001-01-01

    A system of area monitors to detect the involuntary exit of the radiation sources used in low dose rate deferred brachytherapy treatment is being implemented in all facilities in Chile. The first implementation of this system, named 'Early Alert', was 5 years ago as a complement to the administrative procedures and verification measures by the medical physics carried out through visual verifications and by means of portable radiation detectors. This detector of the system should be located preferentially at the exit of the treatment room at a height not smaller than two meters. This has resulted in an increase of facilities safety in this practice. (author) [es

  9. Verification of traceability and backscattering in surface entrance air kerma measurements with detector type ionizing chamber

    International Nuclear Information System (INIS)

    Teixeira, G.J.; Peixoto, J.G.P.

    2013-01-01

    Measurements of doses in radiology services by ionizing chambers are easier than those made by TLD, however the protocols for measurements differ regarding the calibration. The objectives were to verify the traceability in the measures of ESAK corrected by the inverse square law, due to the difference in position between the source and IC and the influence of the backscattered radiation in bringing the detector to the table. Was defined a procedure practiced by the radiological services and designed experimental arrangements for the same technique. Was noted that the approximation of the detector to the table generated a significant backscattered. (author)

  10. The dural entrance of cerebral bridging veins into the superior sagittal sinus: an anatomical comparison between cadavers and digital subtraction angiography

    International Nuclear Information System (INIS)

    Han, Hui; Tao, Wei; Zhang, Ming

    2007-01-01

    Intracranial venous structures have received increasing attention due to improved neuroimaging techniques and increased awareness of cerebral venous disease. To date, few studies have attempted to investigate the dural entrance of the cerebral bridging vein (BV). The aim of this study was to use the superior sagittal sinus (SSS) as an example to identify anatomical features of the dural entrance of the BVs into the SSS in both human cadavers and digital subtraction angiography (DSA) images. A total of 30 adult and 7 fetal human cadavers and 36 patients were examined with anatomical dissections, vascular casting and DSA. The number, diameter and angle of the BVs entering the SSS were measured and compared between the cadavers and DSA images. The results demonstrated that (1) the way a BV entered the SSS varied in three dimensions, and thus the BV dural entrance was difficult to precisely localize by DSA, (2) the distribution pattern of the dural entrance of the BVs into the SSS was relatively constant and a nontributary segment of the SSS was centered at the coronal suture and was identifiable by DSA, and (3) nearly all the BVs (97%, 561/581) entered the SSS at an angle opposite to the direction of blood flow. Unique anatomical features of the dural entrance of a BV into the SSS should be considered in neuroimaging interpretation of the sinus and its associated veins. (orig.)

  11. The natural history of nest defence in a stingless bee, Tetragonisca angustula (Latreille) (Hymenoptera: Apidae), with two distinct types of entrance guards.

    Science.gov (United States)

    Grüter, C; Kärcher, M H; Ratnieks, F L W

    2011-01-01

    The stingless bee Tetragonsica angustula (Latreille) is the only social bee known that has two different types of nest entrance guards. As in other stingless bees and the honey bee one type stands on, in or near the nest entrance. The second type, so far only known in T. angustula, hovers near the nest entrance. In order to gain further understanding of this unique situation we studied guarding behaviour in both types of guards. Using marked bees, we found that individual worker bees guarded for a long time, up to 20 days, relative to their short, average c. 21 day, lifespan. Relatively few, 33%, individually marked guards were seen performing both types of guarding. The others only acted as standing guards. The bees that did perform both types did so over similar periods of their life. Hovering bouts were 57 min long, interrupted by breaks inside the hive of a few minutes (3.3 ± 1.5 min). Standing bouts were slightly longer (74 min) and also interrupted by short breaks (7.82 ± 6.45 min). Human breath, mimicking a vertebrate intruder, caused the guards to retreat into the nest rather than to attack the intruder. Some colonies protected themselves against intruders by closing the entrance during the night (32% and 56% of colonies during two nights). In summary, our results indicate that nest entrance guarding in T. angustula involves division of labour between the two types, in which most guarding individuals only act as standing guards.

  12. Actual trends in patients dose reduction in radiodiagnostic

    International Nuclear Information System (INIS)

    Nikodemova, D.; Gomola, I.; Horvathova, M.

    2001-01-01

    In our contribution we tried to survey the entrance surface doses, as well as dose area product measurements by studying 3 types of radiodiagnostic examinations (mammography, chest examination of children and fluoroscopy). The analysis of the obtained data and their comparison with reference values of European Union has demonstrated the significant role of radiation protection dosimetry as an integral part of quality assurance strategy in radiology. Optimisation in radiodiagnostic requires fulfilling the following criteria: - patient doses to be in accordance with accepted diagnostic practice; - patient doses to be as low as reasonably practicable in order to achieve the required diagnostic results; - professionals clinically and physically directing medical exposures to be familiar with typical doses, methods of measurements and means of dose reduction. One of the basic requirements for continuous quality improvement is the repeating cycle of patient dose measurements for determining the level of risk associated with particular radiological examination at given radiodiagnostic department. Beside the undeniable positive influence of Quality Assurance (QA) procedures possible negative effects should be avoided. The danger exist that the development of new techniques is slowed down by standardising all procedures and wide agreement in implementing of required modifications. Reaching of a consensus of a certain procedure became therefore a labour intensive and time-consuming process. (authors)

  13. Real-time personal dose monitoring and management system

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Cheng Chang; Yang Huating; Liu Zhengshan; Deng Changming; Li Mei

    2000-01-01

    This paper mainly describes a real-time personal dose monitoring and management system. The system is composed of three parts that include SDM-98 semiconductor detector personal dosimeters, Data Readers and a Management System Software. It can be used for personal dose monitoring and management and other controlling actions in a radioactive controlled area. Adopting semiconductor detector and microcontroller, SDM-98 Personal Dosimeter is used to measure personal accumulated dose equivalent and dose rate caused by X-ray and Gamma ray. The results can be read directly on LCD. All the data stored in dosimeter can be transmitted into a data reader by infrared optical link. The alarm threshold can be adjusted successively in whole range of dose or dose rate. The Data Reader is an intelligent interface between the dosimeter and master computer. The data received from dosimeter will be sent to a master computer through RS-232 serial interface. According to the master computer's order, the Data Reader can turn on the dosimeter's power at entrance and shutdown it at exit. The Management System Software which written by Visual BASIC 5.0 runs on MS Win95. All the measuring data from dosimeters can be analyzed and treated according to requirements and stored in database. Therefore, some figures and tables relative to dose or rate can be shown on screen or printed out. (author)

  14. Incorporating partial shining effects in proton pencil-beam dose calculation

    International Nuclear Information System (INIS)

    Li Yupeng; Zhang Xiaodong; Lii Mingfwu; Sahoo, Narayan; Zhu, Ron X; Gillin, Michael; Mohan, Radhe

    2008-01-01

    A range modulator wheel (RMW) is an essential component in passively scattered proton therapy. We have observed that a proton beam spot may shine on multiple steps of the RMW. Proton dose calculation algorithms normally do not consider the partial shining effect, and thus overestimate the dose at the proximal shoulder of spread-out Bragg peak (SOBP) compared with the measurement. If the SOBP is adjusted to better fit the plateau region, the entrance dose is likely to be underestimated. In this work, we developed an algorithm that can be used to model this effect and to allow for dose calculations that better fit the measured SOBP. First, a set of apparent modulator weights was calculated without considering partial shining. Next, protons spilled from the accelerator reaching the modulator wheel were simplified as a circular spot of uniform intensity. A weight-splitting process was then performed to generate a set of effective modulator weights with the partial shining effect incorporated. The SOBPs of eight options, which are used to label different combinations of proton-beam energy and scattering devices, were calculated with the generated effective weights. Our algorithm fitted the measured SOBP at the proximal and entrance regions much better than the ones without considering partial shining effect for all SOBPs of the eight options. In a prostate patient, we found that dose calculation without considering partial shining effect underestimated the femoral head and skin dose

  15. [Evaluation of patient doses in interventional radiology].

    Science.gov (United States)

    Ropolo, R; Rampado, O; Isoardi, P; Gandini, G; Rabbia, C; Righi, D

    2001-01-01

    To verify the suitability of indicative quantities to evaluate the risk related to patient exposure, in abdominal and vascular interventional radiology, by the study of correlations between dosimetric quantities and other indicators. We performed in vivo measurements of entrance skin dose (ESD) and dose area product (DAP) during 48 procedures to evaluate the correlation among dosimetric quantities, and an estimation of spatial distribution of exposure and effective dose (E). To measure DAP we used a transmission ionization chamber and to evaluate ESD and its spatial distribution we used radiographic film packed in a single envelope and placed near the patient's skin. E was estimated by a calculation software using data from film digitalisation. From the data derived for measurements in 27 interventional procedures on 48 patients we obtained a DAP to E conversion factor of 0.15 mSv / Gy cm2, with an excellent correlation (r=.99). We also found a good correlation between DAP and exposure parameters such as fluoroscopy time and number of images. The greatest effective dose was evaluated for a multiple procedure in the hepatic region, with a DAP value of 425 Gy cm2. The greatest ESD was about 550 mGy. For groups of patients undergoing similar interventional procedures the correlation between ESD and DAP had conversion factors from 6 to 12 mGy Gy-1 cm-2. The evaluation of ESD and E by slow films represents a valid method for patient dosimetry in interventional radiology. The good correlation between DAP and fluoroscopy time and number of images confirm the suitability of these indicators as basic dosimetric information. All the ESD values found are lower than threshold doses for deterministic effects.

  16. Correlation between scatter radiation dose at height of operator's eye and dose to patient for different angiographic projections

    International Nuclear Information System (INIS)

    Leyton, Fernando; Nogueira, Maria S.; Gubolino, Luiz A.; Pivetta, Makyson R.; Ubeda, Carlos

    2016-01-01

    Studies have reported cases of radiation-induced cataract among cardiology professionals. In view of the evidence of epidemiological studies, the ICRP recommends a new threshold for opacities and a new radiation dose to eye lens limit of 20 mSv per year for occupational exposure. The aim of this paper is to report scattered radiation doses at the height of the operator's eye in an interventional cardiology facility without considering radiation protection devices and to correlate these values with different angiographic projections and operational modes. Measurements were taken in a cardiac laboratory with an angiography X-ray system equipped with flat-panel detector. PMMA plates of 30×30×5 cm were used with a thickness of 20 cm. Measurements were taken in two fluoroscopy modes (low and normal, 15 pulses/s) and in cine mode (15 frames/s). Four angiographic projections were used: anterior posterior; lateral; left anterior oblique caudal (spider); and left anterior oblique cranial, with a cardiac protocol for patients weighing between 70 and 90 kg. Measurements of phantom entrance dose rate and scatter dose rate were performed with two Unfors Xi plus detectors. The detector measuring scatter radiation was positioned at the usual distance of the cardiologist's eyes during working conditions. There is a good linear correlation between the kerma area product and scatter dose at the lens. Experimental correlation factors of 2.3, 12.0, 12.2 and 17.6 μSv/Gy cm2 were found for different projections. PMMA entrance dose rates for low and medium fluoroscopy and cine modes were 13, 39 and 282 mGy/min, respectively, for AP projection. - Highlights: • A method is presented to estimate the scatter radiation dose at operator eye height. • The method allows estimating scatter radiation dose measuring ambient dose equivalent. • Operator could exceed threshold for lens opacities if protection tools are not used. • There is a good linear correlation between kerma

  17. Effective dose of individuals from the surrounding public to the facilities of the Abadia de Goiás radioactive waste disposal

    International Nuclear Information System (INIS)

    Ribeiro, E.; Borges, A.F. de Almeida; Camargos, K.M.; Santos, E.E. dos; Correa, R. da S.; Ferreira, N.C.; Ribeiro, N.V.

    2017-01-01

    The study presents the level of effective annual dose that individuals from the public - surrounding the repository of wastes with Cs-137, located in Abadia de Goiás, GO, Brazil - have received, according to analyzes carried out from June 2015 to July 2016. It was considered reference to the annual effective radiation dose limit of 0.3 mSv / year established by the National Nuclear Energy Commission (CNEN) for the impact of repositories on individuals in the public. Cs-137 activity determinations were performed on samples of surface water (ASU), groundwater (ASB), river bottom sediments (SED), soil (SOL) and vegetation (VEG). With these results, the effective doses were estimated for ASU and BSA consumption of 6.64 x 10 -4 mSv / year and for SED exposure, 3.92 x 10 - 6 mSv / year and for ASB use, 6.22 x 10 -3 mSv / year. For SOL and VEG, activity values of Cs-137 were used as indicators of contamination. It was observed that the effective annual doses were below the limit established by the norms, which can be inferred that the installation has been operating safely, without causing a radiological impact to the environment and individuals of the public

  18. Impact of quality control radiation doses received by patients undergoing abdomen x-ray examination in ten hospitals

    International Nuclear Information System (INIS)

    Aghahadi, B.; Zhang, Z.; Zareh, S.; Sarkar, S.; Tayebi, P. S.

    2006-01-01

    The X-ray machines used for radiodiagnosis should meet certain quality assurance programmes. These are necessary to have good quality radiographs at reasonably low exposure to patients. Materials and Methods: Dose reduction methods in abdomen X-ray examination were carried out in 10 hospitals in Tehran. This paper presents the work, which was implemented on 200 patients and evaluated using the entrance skin dose in the Anterior-Posterior abdomen projection measured directly at the center of the X-ray field. In addition, the machine room, and dark room parameters, as well as work practices and repeat rates were studied. Results: The quality control parameters and the entrance skin dose were evaluated utilizing an anthropologic phantom to define the optimal exposure condition at all hospitals before and after quality control . Results show that after using the quality control parameters and optimization of the exposure conditions, the mean of mAs and entrance skin dose can be decreased by 62% and 65% respectively. Conclusion: The quality of the radiographs generally increased. The reported method is easily implemented in any clinical situation where optimization of abdomen radiography is necessary

  19. Determining the Correlation Between Language Scores Obtained by Medical Students in their University Entrance and Comprehensive Medical Basic Sciences Exams

    Directory of Open Access Journals (Sweden)

    Majid Ahmadi

    2009-06-01

    Full Text Available Background and Purpose: Some professors and educators in the field of English language believe that the high grades attained by medical students in their Comprehensive Medical Basic Sciences Exam (CMBSE are mainly a result of the students prior fluency in the language before entering medical colleges; they are of the opinion that these grades are not necessarily a result of the combined effort of the English teachers and students in language courses at the university. This research aimsat determining the correlation between the level of fluency in English of medical students prior to university entrance and the grades obtained by them in their CMBSE after 3 terms of language courses at the university.Methods: Seven of the major and smaller universities of medical sciences were selected. The language scores of 2426 students admitted to these universities during the three academic years of 1999 to 2002 in both the National University Entrance Examination (NUEE and the Comprehensive Medical Basic Sciences Exam (CMBSE were obtained from their related universities and from the secretariat of the Council of Medical Basic Sciences Education respectively. The language scores of each studentobtained in both NUEE and CMBSE were then matched. The related SPSS software was used to assess the level of correlation between these two groups of language scores for the students of each university, for each academic year and semester and also the overall score for the three years.Results: Overall a positive and moderately significant correlation was found between the NUEE language scores and those of the CMBSE of the students of the universities studied (P<0/001; R=443%. The level of correlation for the various universities studied differed (Max. 69%, min.27%.A comparison of the means of these two groups of scores also confirmed this correlation.Conclusion: students’ grades The NUEE language score was not the only factor affecting the student’s CMBSE score

  20. Transient forced convection with viscous dissipation to power-law fluids in thermal entrance region of circular ducts with constant wall heat flux

    International Nuclear Information System (INIS)

    Dehkordi, Asghar Molaei; Mohammadi, Ali Asghar

    2009-01-01

    A numerical investigation was conducted on the transient behavior of a hydrodynamically, fully developed, laminar flow of power-law fluids in the thermally developing entrance region of circular ducts taking into account the effect of viscous dissipation but neglecting the effect of axial conduction. In this regard, the unsteady state thermal energy equation was solved by using a finite difference method, whereas the steady state thermal energy equation without wall heat flux was solved analytically as the initial condition of the former. The effects of the power-law index and wall heat flux on the local Nusselt number and thermal entrance length were investigated. Moreover, the local Nusselt number of steady state conditions was correlated in terms of the power-law index and wall heat flux and compared with literature data, which were obtained by an analytic solution for Newtonian fluids. Furthermore, a relationship was proposed for the thermal entrance length

  1. Radiation Dose Assesment And Risk Estimation During Extracorporeal Shock Wave Lithotripsy

    International Nuclear Information System (INIS)

    Sulieman, A.; Ibrahim, A.A.; Osman, H.; Yousef, M.

    2011-01-01

    Extracorporeal shockwave lithotripsy (ESWL) is considered the gold standard for calculi fragmentation. The aims of this study are to measure the entrance surface dose (ESD) using thermo-luminescence dosimeter (TLDs) and to estimate the probability of carcinogenesis during ESWL procedure. The study was carried out at two centers (Group A, 50 patients) and (Group B, 25 patients). The mean ESD and effective doses were 36 mGy and 34 mSv. The results show that the probability of carcinogenesis is a tiny value 100 per million patients) but the main biological effect is occurring due to the accumulative impact of radiation.

  2. Fathers' characteristics and their children's scores on college entrance exams: a comparison of intact and divorced families.

    Science.gov (United States)

    Furr, L A

    1998-01-01

    Previous research shows that the educational performance of children may be impaired when their parents divorce. However, noncustodial fathers' postdivorce behavior, especially compliance with child support orders, can greatly offset educational disadvantages. The present study investigated the impact of fathers' behavior on their children's performance on college entrance examinations (CEEs) in a sample of 231 college students. Results indicated that, in intact families, fathers' ethnicity and income were related to CEE scores. Further, when these students perceived their fathers as encouraging and involved in their education, their scores were higher. For students with divorced parents, however, noncustodial fathers' ethnicity, income, encouragement, involvement, child support compliance, and visitation were not statistically linked to CEE performance. These findings suggest that joint custodial arrangements, which may enhance the social relationships between fathers and their children, may lead to improved educational outcomes.

  3. Magnetic structure in the entrance region of spheromaks sustained by a magnetized coaxial plasma gun under long pulse operation

    International Nuclear Information System (INIS)

    Amemiya, Naoyuki; Takaichi, Kazuaki; Katsurai, Makoto

    1989-01-01

    The magnetic structure in coaxial-gun-sustained spheromaks has been investigated. The plasma gun has been operated with a small axial/radial bias magnetic flux as compared to the azimuthal magnetic flux produced by the discharge current. Stronger magnetic field is observed in the entrance region (ER) than in the flux conserver (FC). In both ER and FC, the magnetic structure is nearly axisymmetric. The axial magnetic field in ER is amplified up to about sixteen times as large as the bias magnetic field. This amplification is limited by the drastic change in the magnetic structure, which occurs when the discharge current becomes very large. The magnetic structure before the drastic change is interpreted with the Bessel function model. The μ estimation shows that the magnetic structure is mainly determined by the boundary geometry, not by the external magnetic flux and current. (author)

  4. First demonstration of improving laser propagation inside the spherical hohlraums by using the cylindrical laser entrance hole

    Directory of Open Access Journals (Sweden)

    Wenyi Huo

    2016-01-01

    Full Text Available The octahedral spherical hohlraums have natural superiority in maintaining high radiation symmetry during the entire capsule implosion process in indirect drive inertial confinement fusion. While, in contrast to the cylindrical hohlraums, the narrow space between the laser beams and the spherical hohlraum wall is usually commented. In this Letter, we address this crucial issue and report our experimental work conducted on the SGIII-prototype laser facility which unambiguously demonstrates that a simple design of cylindrical laser entrance hole (LEH can dramatically improve the laser propagation inside the spherical hohlraums. In addition, the laser beam deflection in the hohlraum is observed for the first time in the experiments. Our 2-dimensional simulation results also verify qualitatively the advantages of the spherical hohlraums with cylindrical LEHs. Our results imply the prospect of adopting the cylindrical LEHs in future spherical ignition hohlraum design.

  5. Application of a simple phantom in assessing the effects of dose reduction on image quality in chest radiography

    International Nuclear Information System (INIS)

    Egbe, N.O.; Heaton, B.; Sharp, P.F.

    2010-01-01

    Purpose: Firstly, to evaluate a commercial chest phantom incorporating a quasi anthropomorphic insert by comparing exposure measurements on the phantom with those of actual patients and, secondly, to assess the value of the phantom for image quality and dose optimisation. Methods: In the first part of the study entrance surface doses (ESD), Beam transmission (BT), and optical density (OD) were obtained for 77 chest radiography patients and compared with measurements made from exposures of the phantom using the respective patient exposure factors from chest examination. Differences were assessed with a student t-test, while the Pearson's linear correlation coefficient was used to test for any linear relationship. The second part assessed the applicability of the phantom to image quality studies by investigating the effect, on the clarity and detectability of lung lesions made from gelatine, of reducing patient dose below current dose levels. Clarity of linear objects of different dimensions was also studied. Lesion detectability and clarity was assessed by four observers. The possibility of extending dose reduction below current dose levels (D ref ) was assessed from comparison of doses that produced statistically significant differences in image quality from D ref . Results: Results show that, with the exception of entrance doses and beam transmission through the diaphragm (P > 0.05), differences in OD and beam transmission between patients and phantom were statistically significant (P ref produced significant changes in both clarity and detectability. Conclusion: Within limits posed by the observed differences, the phantom can be applied to image quality studies in diagnostic radiology.

  6. Computerized x-ray dose-monitoring system

    International Nuclear Information System (INIS)

    Hummel, R.H.; Wesenberg, R.L.; Amundson, G.M.

    1985-01-01

    An x-ray dose-monitoring system using a small digital computer is described. Initially, and for every 6 months afterward, the system is calibrated using an exposure meter. For each exposure, the computer receives values of x-ray technique and beam geometry from the x-ray generator through a specially designed electronic interface. Then, by means of calibration data, entrance exposure, area exposure product, and integral dose are obtained and printed for each patient examined. The overall accuracy of the system is better than +/-20%. Operation is semiautomatic, requiring minimum operator intervention. Over 2000 patients have been monitored with the device. Because the system is computer-based, it offers the opportunity for statistical analysis of the data base created, as the results for each patient are stored on computer disk

  7. Radiation Doses in Intravenous Urography And Potentials For Optimization

    International Nuclear Information System (INIS)

    Halato, M.A.; Badawi, A.; Gassom, G.A.; Barsham, M.A.; Ibrahim, A.F.; Suliman, I.I.; Sulieman, A.A.

    2011-01-01

    In this study radiation doses in IVU clinical examinations were measured in three public hospitals and a sample of 44 patients. In each room the machine output was measured for different peak tube voltages. Patient's data such as (age and weight) and exposure parameters (kVp) and mAs) were recorded. Entrance Surface Air Kerma (ESAK) for patients was determined by using the tube output and the patient exposure parameters. The ESAK ranged from 0.76 to 6.75 mGy. The cumulative ESAK ranged from 3.5 to 34.6 mGy. In conclusion, the obtained results are in agreement with the standard reference ESAK levels. The study showed that the cumulative ESAK can approach a level known to increase the probability of stochastic effect. Keywords: Patient dose, intravenous Urography, radiation protection

  8. Radiation Dose Measurements in Routine X Ray Examinations

    International Nuclear Information System (INIS)

    Osman, H.; Sulieman, A.; Suliman, I.I.; Sam, A.K.

    2011-01-01

    The aim of current study was to evaluate patients radiation dose in routine X-ray examinations in Omdurman teaching hospital Sudan.110 patients was examined (134) radiographs in two X-ray rooms. Entrance surface doses (ESDs) were calculated from patient exposure parameters using DosCal software. The mean ESD for the chest, AP abdomen, AP pelvis, thoracic spine AP, lateral lumber spine, anteroposterior lumber spine, lower limb and for the upper limb were; 231±44 Gy,453± 29 Gy, 567±22 Gy, 311±33 Gy,716±39 Gy, 611±55 Gy,311±23 Gy, and 158±57 Gy, respectively. Data shows asymmetry in distribution. The results of were comparable with previous study in Sudan.

  9. RESEARCH OF THE ENTRANCE ANGLE EFFECT ON THE REFLECTANCE SPECTRA OF THE STAINLESS STEEL SURFACE OXIDIZED BY PULSED LASER RADIATION

    Directory of Open Access Journals (Sweden)

    V. P. Veiko

    2016-05-01

    Full Text Available Subject of Research.Oxide films on the metal surfaces can be obtained both by surface-uniform infrared heating and local laser treatment e.g. by sequence of nanosecond laser pulses. Due to interference in created films the coloration of treated area is observed. The present work shows the results of spectrophotometric measurements for various light entrance angles in the range of 10-60°. Method. AISI 304 stainless steel plates were oxidized by two methods: in muffle furnace FM - 10 (Т= 500-600° С, t = 5-7 min. and at line-by-line scanning by sequence of nanosecond laser pulses (λ = 1.06 μm, τ =100 ns, r = 25 μm,q=2.91∙107 W/cm2, Nx = 30, Ny = 1. Surface research in optical resolution was realized by Carl Zeiss Axio Imager A1M. Reflectance spectra were obtained with spectrophotometer Lambda Perkin 1050 with integrating sphere at different fixed light incidence angles. Topographic features were detected by scanning probe microscopy investigation with NanoEducator equipment. Main Results. The quantitative surface geometry characteristics of AISI 304 stainless steel patterns treated by different methods are obtained. It was found that the increase of light entrance angle has no influence on the form of reflection coefficient dependence from a wavelength, but a blue-shift occurs especially for the case of laser treatment. This difference can be caused by surface topology formed by laser heating and variety of oxide film thickness. This effect results in more significant change in observed sample color for laser treatment then for infrared heating. Practical Relevance. The results obtained in the present work can be used to implement a new element of product protection against forgery with the product marking.

  10. Factors influencing the imposition of a charge on the entrance to the interpretive trails in the large protected areas

    Directory of Open Access Journals (Sweden)

    Josef Navrátil

    2013-01-01

    Full Text Available The aim of this paper is to assess the relation between the character of the interpretive trail and the imposition of a charge on the entrance. This was done using the discrete choice experiment that involves eight attributes, seven of which are with three levels: the overall character of the trail, the way that the route signs are used in the terrain, the ways of providing information, the length of the trail, the way of the routing, the focus of the trail, and the price of the entrance. There is also one with two levels that involves the existence of the places for rest. The fractional factorial design was used (the orthogonal main effects plan and the Multinomial Logit Model was used in analyzing the data. The 2,830 choices were done by random sampled visitors from eight tourist locations in the Tourist Regions of the Šumava Mts. and South Bohemia during the summer season 2012. The impact of the character of the trail was especially detected in the model. Except for that, the equipment of the trail and its length have had the fundamental impact on the choice of the trail as well. Those longer and worse equipped trails have a significantly lower degree of utility for the respondents. What is quite surprising is that the respondents refused the ecotourism elements of the interpretive trails, such as the possibility of going through the trail on horseback or the accompaniment of an expert who would provide some comments, as it is common to do this at historical attractions within those sightseeing paths.

  11. Computational and experimental studies of the flow field near the beam entrance window of a liquid metal target

    International Nuclear Information System (INIS)

    Geža, Vadims; Milenković, Rade Ž.; Kapulla, Ralf; Dementjevs, Sergejs; Jakovičs, Andris; Wohlmuther, Michael

    2014-01-01

    Highlights: • Water model of liquid metal target for validation of CFD models was built. • PIV measurements showed flow features in the region near beam entrance window. • The zones with high turbulence kinetic energy were distinguished. • Reasonable agreement between modeling and PIV data was obtained. - Abstract: After the first world liquid metal target has been successfully operated at the SINQ facility at the Paul Scherrer Institut (PSI) for 6 months. The idea of having a reliable target with a bypass flow for cooling the beam entrance window, but with the bypass flow not driven by a separate pump, was examined within the project called LIMETS (Liquid Metal Target for SINQ). In designing of liquid metal targets, turbulence modelling is of high importance due to lack in methods for measuring the spatial distribution of flow and turbulence characteristics. In this study, validation of different turbulence models were performed in water model with hemispherical geometry using particle image velocimetry (PIV) technique. Two components of water flow velocity in plexiglas container with inner radius of 88 mm were measured in different cross sections, with the velocities varying from 1 to 10 m/s. Numerical calculations using large eddy simulation (LES) approach and Reynolds averaged Navier–Stokes (RANS) models were carried out to validate their applicability and study performance issues. Mean velocity and turbulence kinetic energy data were used for comparison of PIV and calculation results. Reasonable agreement was obtained for mean velocity data, with some discrepancies due to the limited length of the inlet tube. However, several discrepancies in turbulence characteristics were found in numerical results, especially in RANS model calculations

  12. Measurement of radiation dose in paediatric micturating cystourethrography

    International Nuclear Information System (INIS)

    Hassan, N. E. A.

    2013-06-01

    Paediatrics and children have been recognized that they have a higher risk of developing cancer from the radiation than adults. Therefor, increased attention has been directed towards the dose to the patients. Micturating Cystourethrography (MCU) is a commonly use ed fluoroscopic procedure in children and commonly used to detect the vesicoureteric reflux (VUR) and show urethral and bladder and abnormalities. This study aims to measure the pediatric patients undergoing MCU. The study was carried out in two hospitals in Khartoum. The entrance surface dose (ESD) was determined determined by indirect method for 45 children. Furthermore, the mean ESD, sd and range resulting from MCU procedures has been estimated to be 0.7±.5 (0.2-2.5) mGy for the total patient population. The radiation dose to the patients is well within established safety limits, in the light of the current practice. The radiation dose results of this study are appropriate for adoption as the local initial dose reference level (DRL) value for this technique. The data presented in this study showed our doses to be approximately 50% lower than the lower mean values presented in the literature.(Author)

  13. Evaluation of radiation dose received in skull radiographic examination

    International Nuclear Information System (INIS)

    Omer, Noora Elshiekh

    2014-12-01

    Diagnostic X-ray examination play an important role in the health care of the population. These examinations may involve significant irradiation of the patient and probably represent the largest mam-made source of radiation exposure for the population. This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study was performed to assess the effective dose (ED) received in skull radiographic examination and to analyze effective dose distributions among radiological department under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 50 patients. The following parameters were recorded: age, weight, height, body mass index (BMI) derived from weight (kg) and (height (m)) and exposure factors. The dose was measured for skull x-ray examinations. For effective dose calculation, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for skull AP and lateral examinations. The ED values were then calculated from the obtained ESD values using IAEA calculation methods. Effective doses were calculated from energy imparted using ED conversion factors proposed were within the normal range of exposure. The mean ED values calculated were 3.03±0.08 and 4.23±0.61 for skull AP and lateral examination, respectively. Further studies are recommended with more number of patients and using more than two modalities for comparison. (Author)

  14. Assessment of patient radiation doses during routine diagnostic radiography examinations

    International Nuclear Information System (INIS)

    Adam, Asim Karam Aldden Adam

    2015-11-01

    Medical applications of radiation represent the largest source of exposure to general population. Accounting for 3.0 mSv against an estimated 2.4 mSv from a natural back ground in United States. The association of ionizing radiation an cancer risk is assumed to be continuos and graded over the entire range of exposure, The objective of this study is to evaluate the patient radiation doses in radiology departments in Khartoum state. A total of 840 patients ? during two in the following hospitals Khartoum Teaching Hospital (260 patients), Fedail specialized hospital ( 261 patients). National Ribat University hospital ( 189 patients) and Engaz hospital (130 patients). Patient doses were measured for 9 procedures. The Entrance surface Air Kerma (ESAK) was quantified using x-ray unit output by Unifiers xi dose rate meter( Un fore inc. Billdal. Sweden) and patient exposure parameters. The mean patient age. Weight and Body Mass index (BMI) were 42.6 year 58/4 kg and 212 kg/m respectively. The mean patient doses, kv and MAS and E.q was 0.35 mGy per procedures 59.9 volt 19.8 Ampere per second 0.32 Sv . Patient doses were comparable with previous studies. Patient radiation doses showed considerable difference between hospitals due to x- ray systems exposure settings and patient weight. Patient are exposed to unnecessary radiation.(Author)

  15. Patient absorbed radiation doses estimation related to irradiation anatomy

    International Nuclear Information System (INIS)

    Soares, Flavio Augusto Penna; Soares, Amanda Anastacio; Kahl, Gabrielly Gomes

    2014-01-01

    Developed a direct equation to estimate the absorbed dose to the patient in x-ray examinations, using electric, geometric parameters and filtering combined with data from irradiated anatomy. To determine the absorbed dose for each examination, the entrance skin dose (ESD) is adjusted to the thickness of the patient's specific anatomy. ESD is calculated from the estimated KERMA greatness in the air. Beer-Lambert equations derived from power data mass absorption coefficients obtained from the NIST / USA, were developed for each tissue: bone, muscle, fat and skin. Skin thickness was set at 2 mm and the bone was estimated in the central ray of the site, in the anteroposterior view. Because they are similar in density and attenuation coefficients, muscle and fat are treated as a single tissue. For evaluation of the full equations, we chose three different anatomies: chest, hand and thigh. Although complex in its shape, the equations simplify direct determination of absorbed dose from the characteristics of the equipment and patient. The input data is inserted at a single time and total absorbed dose (mGy) is calculated instantly. The average error, when compared with available data, is less than 5% in any combination of device data and exams. In calculating the dose for an exam and patient, the operator can choose the variables that will deposit less radiation to the patient through the prior analysis of each combination of variables, using the ALARA principle in routine diagnostic radiology sector

  16. Assessment of dose received by organ in lumbosacral examination

    International Nuclear Information System (INIS)

    Eltyeib, Nashwa Kheirallah

    2014-11-01

    The biological damage produced by radiation is closely related to the amount of energy absorbed in the case x- rays. Measurement of produced ionizing provides a useful assessment of the total energy absorbed. This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study was performed to assess the effective dose (ED) received in lumbosacral radiography examination and to analyze effective dose distributions among radiological department under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 50 patients. The following parameters were recorded: age weight, height, body mass index (BMI) derived from mass (kg) and (height. (m)) and exposure factors. The dose was measured for lumbosacral x- rays examination. For effective dose calculation, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for lumbosacral spine A P and lateral examinations. The ED values were then calculated from the obtained ESD values using IAEA calculation methods. Effective doses were than calculated from energy imported using ED conversion factors by IAEA. The results of ED values calculated showed that patient exposures were within the normal range of exposure. The mean ED values calculated were (2.49 ±0.03) mGy and (5.5.60 ± 0.0.22) mGy for Lumbosacral spine A P and lateral examinations, respectively. Further studies are recommended with more number of patients and using more modalities for comparison.(Author)

  17. Influence of Flat-Panel Fluoroscopic Equipment Variables on Cardiac Radiation Doses

    International Nuclear Information System (INIS)

    Nickoloff, Edward L.; Lu Zhengfeng; Dutta, Ajoy; So, James; Balter, Stephen; Moses, Jeffrey

    2007-01-01

    Purpose. To assess the influence of physician-selectable equipment variables on the potential radiation dose reductions during cardiac catheterization examinations using modern imaging equipment. Materials. A modern bi-plane angiography unit with flat-panel image receptors was used. Patients were simulated with 15-30 cm of acrylic plastic. The variables studied were: patient thickness, fluoroscopy pulse rates, record mode frame rates, image receptor field-of-view (FoV), automatic dose control (ADC) mode, SID/SSD geometry setting, automatic collimation, automatic positioning, and others. Results. Patient radiation doses double for every additional 3.5-4.5 cm of soft tissue. The dose is directly related to the imaging frame rate; a decrease from 30 pps to 15 pps reduces the dose by about 50%. The dose is related to [(FoV) -N ] where 2.0 < N < 3.0. Suboptimal positioning of the patient can nearly double the dose. The ADC system provides three selections that can vary the radiation level by 50%. For pediatric studies (2-5 years old), the selection of equipment variables can result in entrance radiation doses that range between 6 and 60 cGy for diagnostic cases and between 15 and 140 cGy for interventional cases. For adult studies, the equipment variables can produce entrance radiation doses that range between 13 and 130 cGy for diagnostic cases and between 30 and 400 cGy for interventional cases. Conclusions. Overall dose reductions of 70-90% can be achieved with pediatric patients and about 90% with adult patients solely through optimal selection of equipment variables

  18. Estimating effective doses to children from CT examinations

    International Nuclear Information System (INIS)

    Heron, J.C.L.

    2000-01-01

    Full text: Assessing doses to patients in diagnostic radiology is an integral part of implementing optimisation of radiation protection. Sources of normalised data are available for estimating doses to adults undergoing CT examinations, but for children this is not the case. This paper describes a simple method for estimating effective doses arising from paediatric CT examinations. First the effective dose to an adult is calculated, having anatomically matched the scanned regions of the child and the adult and also matched the irradiation conditions. A conversion factor is then applied to the adult effective dose, based on the region of the body being scanned - head, upper or lower trunk. This conversion factor is the child-to-adult ratio of the ratios of effective dose per entrance air kerma (in the absence of the patient) at the FAD. The values of these conversion factors were calculated by deriving effective dose per entrance air kerma at the FAD for new-born, 1, 5, 10, 15 and adult phantoms using four projections (AP, PA, left and right laterals) over a range of beam qualities and FADs.The program PCXMC was used for this purpose. Results to date suggest that the conversion factors to give effective doses for children undergoing CT examinations of the upper trunk are approximately 1.3, 1.2, 1.15, 1.1 and 1.05 for ages 0, 1, 5, 10 and 15 years respectively; CT of the lower trunk - 1.4, 1.3, 1.2, 1.2, 1.1; and CT of the head - 2.3, 2.0, 1.5, 1.3, 1.1. The dependence of these factors on beam quality (HVL from 4 to 10 mm Al) is less than 10%, with harder beams resulting in slightly smaller conversion factors. Dependence on FAD is also less than 10%. Major sources of uncertainties in the conversion factors include matching anatomical regions across the phantoms, and the presence of beam divergence in the z-direction when deriving the factors. The method described provides a simple means of estimating effective doses arising from paediatric CT examinations with

  19. Assessment of radiological parameters and patient dose audit using semi-empirical model

    International Nuclear Information System (INIS)

    Olowookere, C.J.; Onabiyi, B.; Ajumobi, S. A.; Obed, R.I.; Babalola, I. A.; Bamidele, L.

    2011-01-01

    Risk is associated with all human activities, medical imaging is no exception. The risk in medical imaging is quantified using effective dose. However, measurement of effective dose is rather difficult and time consuming, therefore, energy imparted and entrance surface dose are obtained and converted into effective dose using the appropriate conversion factors. In this study, data on exposure parameters and patient characteristics were obtained during the routine diagnostic examinations for four common types of X-ray procedures. A semi-empirical model involving computer software Xcomp5 was used to determine energy imparted per unit exposure-area product, entrance skin exposure(ESE) and incident air kerma which are radiation dose indices. The value of energy imparted per unit exposure-area product ranges between 0.60 and 1.21x 10 -3 JR -1 cm -2 and entrance skin exposure range from 5.07±1.25 to 36.62±27.79 mR, while the incident air kerma range between 43.93μGy and 265.5μGy. The filtrations of two of the three machines investigated were lower than the standard requirement of CEC for the machines used in conventional radiography. The values of and ESE obtained in the study were relatively lower compared to the published data, indicating that patients irradiated during the routine examinations in this study are at lower health risk. The energy imparted per unit exposure- area product could be used to determine the energy delivered to the patient during diagnostic examinations, and it is an approximate indicator of patient risk.

  20. Pediatric patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Medeiros, R.B.; Murata, C.H.; Moreira, A.C.

    2014-01-01

    The radiation doses from interventional procedures is relevant when treating children because of their greater radiosensitivity compared with adults. The purposes of this paper were to estimate the dose received by 18 pediatric patients who underwent cardiac interventional procedures and to correlate the maximum entrance surface air kerma (Ke,max), estimated with radiochromic films, with the cumulative air kerma values displayed at the end of procedures. This study was performed in children up to 6 years. The study was performed in two hospitals, one located in Recife and the other one in São Paulo. The x-ray imaging systems used were Phillips Allura 12 model with image intensifier system and a Phillips Allura FD10 flat panel system. To estimate the Ke,max on the patient’s skin radiochromic films(Gafchromic XR-RV2) were used. These values were estimated from the maximum optical density measured on film using a calibration curve. The results showed cumulative air kerma values ranging from 78.3- 500.0mGy, with a mean value of 242,3 mGy. The resulting Ke,max values ranged from 20.0-461.8 mGy, with a mean value of 208,8 mGy. The Ke,max values were correlated with the displayed cumulative air kerma values. The correlation factor R² was 0.78, meaning that the value displayed in the equipment’s console can be useful for monitoring the skin absorbed dose throughout the procedure. The routine fluoroscopy time records is not able by itself alert the physician about the risk of dose exceeding the threshold of adverse reactions, which can vary from an early erythema to serious harmful skin damage. (author)