WorldWideScience

Sample records for enriched 124xe target

  1. 124Xe(n,γ)125Xe and 124Xe(n,2n)123Xe measurements for National Ignition Facility

    Science.gov (United States)

    Bhike, Megha; Ludin, Nurin; Tornow, Werner

    2015-05-01

    The cross section for the 124Xe(n,γ)125Xe reaction has been measured for the first time for neutron energies above 100 keV. In addition, the 124Xe(n,2n)123Xe reaction has been studied between threshold and 14.8 MeV. The results of these measurements provide sensitive diagnostic tools for investigating properties of the inertial confinement fusion plasma in Deuterium-Tritium (DT) capsules at the National Ignition Facility (NIF) located at Lawrence Livermore National Laboratory.

  2. 124Xe(n,γ125Xe and 124Xe(n,2n123Xe measurements for National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Bhike Megha

    2015-01-01

    Full Text Available The cross section for the 124Xe(n,γ125Xe reaction has been measured for the first time for neutron energies above 100 keV. In addition, the 124Xe(n,2n123Xe reaction has been studied between threshold and 14.8 MeV. The results of these measurements provide sensitive diagnostic tools for investigating properties of the inertial confinement fusion plasma in Deuterium-Tritium (DT capsules at the National Ignition Facility (NIF located at Lawrence Livermore National Laboratory.

  3. Double beta decay searches of 134Xe, 126Xe and 124Xe with large scale Xe detectors

    International Nuclear Information System (INIS)

    Barros, N; Thurn, J; Zuber, K

    2014-01-01

    The sensitivity for double beta decay studies of 134 Xe and 124 Xe is investigated assuming a potential large scale Xe experiment developed for dark matter searches depleted in 136 Xe. The opportunity for an observation of the 2νββ - decay of 134 Xe is explored for various scenarios. A positive observation should be possible for all calculated nuclear matrix elements. The detection of 2ν ECEC of 124 Xe can be probed in all scenarios covering the theoretical predicted half-life uncertainties and a potential search for 126 Xe is discussed. The sensitivity to β + EC decay of 124 Xe is discussed and a positive observation might be possible, while β + β + decay still remains unobservable. The performed studies take into account solar pp–neutrino interactions, 85 Kr beta decay and remaining 136 Xe double beta decay as background components in the depleted detector. (paper)

  4. Comprehensive sets of 124Xe(n ,γ )125Xe and 124Xe(n ,2 n )123Xe cross-section data for assessment of inertial-confinement deuterium-tritium fusion plasma

    Science.gov (United States)

    Bhike, Megha; Fallin, B.; Gooden, M. E.; Ludin, N.; Tornow, W.

    2015-01-01

    Measurements of the neutron radiative-capture cross section of 124Xe have been performed for the first time for neutron energies above 100 keV. In addition, data for the 124Xe(n ,2 n )123Xe reaction cross section have been obtained from threshold to 14.8 MeV to cover the entire energy range of interest, while previous data existed only at around 14 MeV. The results of these measurements provide the basis for an alternative and sensitive diagnostic tool for investigating properties of the inertial confinement fusion plasma in deuterium-tritium (DT) capsules at the National Ignition Facility located at Lawrence Livermore National Laboratory. Here, areal density ρ R (density × radius) of the fuel, burn asymmetry, and fuel-ablator mix are of special interest. The 124Xe(n ,γ )125Xe reaction probes the down-scattered neutrons, while the 124Xe(n ,2 n )123Xe reaction provides a measure of the 14 MeV direct neutrons.

  5. Current status of the 124Xe target system development for the high purity 123I production in KCCH

    International Nuclear Information System (INIS)

    Chun, Kwon Soo

    2002-01-01

    This report describes the 124 Xe gaseous target system employed for 123 I production at the Korea Cancer Center Hospital. Currently the control system is manual and will be computerized after the system parameters have been established

  6. Recoil distance lifetime measurements in 122,124Xe

    Science.gov (United States)

    Govil, I. M.; Kumar, A.; Iyer, H.; Li, H.; Garg, U.; Ghugre, S. S.; Johnson, T.; Kaczarowski, R.; Kharraja, B.; Naguleswaran, S.; Walpe, J. C.

    1998-02-01

    Lifetimes of the lower-excited states in 122,124Xe are measured using the recoil-distance Doppler-shift technique. The reactions 110Pd(16O,4n)122Xe and 110Pd(18O,4n)124Xe at a beam energy of 66 MeV were used for this experiment. The lifetimes of the 2+, 4+, 6+, and 8+ states of the ground state band were extracted using the computer code LIFETIME including the corrections due to the side feeding and the nuclear deorientation effects. The lifetime of the 2+ state in 122Xe agrees with the recoil distance method (RDM) measurements but for the 124Xe it does not agree with the RDM measurements but agrees with the Coulomb-excitation experiment. The measured B(E2) values for both the nuclei are compared with the standard algebraic and the multishell models.

  7. Nuclear Structure of 124Xe Studied with β+/EC-Decay

    Science.gov (United States)

    Radich, A. J.; Garrett, P. E.; Allmond, J. M.; Andreoiu, C.; Ball, G. C.; Bianco, L.; Bildstein, V.; Chagnon-Lessard, S.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Hackman, G.; Hadinia, B.; Jigmeddorj, B.; Laffoley, A. T.; Leach, K. G.; Michetti-Wilson, J.; Orce, J. N.; Rajabali, M. M.; Rand, E.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Wang, Z. M.; Wood, J. L.; Wong, J.; Williams, S. J.; Yates, S. W.

    The nuclear structure of 124Xe was investigated using γ-ray spectroscopy following the β+/EC-decay of 124Cs. A very high-statistics data set was collected and γγ coincidence data was analyzed, greatly adding to the 124Xe level scheme. A new decay branch from the high-spin isomer of 124Cs was observed as well as weak E2 transitions into excited 0+ states in 124Xe. B(E2) transition strengths of such low-spin transitions are very important in determining collective properties, which are currently poorly characterized in the region of neutron-deficient xenon isotopes.

  8. Production of high purity iodine-123 from xenon-124 at energies between 15 and 34 MeV

    International Nuclear Information System (INIS)

    Firouzbakht, M.L.; Teng Renrui; Schlyer, D.J.; Wolf, A.P.

    1987-01-01

    The production of I-123 from the proton bombardment of isotopically enriched Xe-124 is reported over the energy range of 15 to 34 MeV via the 124 Xe (p,pn) 123 Xe (β + , 2.1 hr) → 123 I and 124 Xe (p,2n) 123 Cs (β + , 6 min) → 123 Xe (β + , 2.1 hr) → 123 I pathways. The thick target yields for this target are tabulated and compared to theoretical cross-section calculations of the nuclear reactions leading to the production of Xe-123. The radiochemical purity of the I-123 is greater than 99.9% and the contamination of I-125 is below detectable limits (< 0.1%) at 6.6 hrs after the end of bombardment. (orig.)

  9. Investigation of 124Xe nuclear structure with the 8Pi spectrometer at TRIUMF-ISAC

    Science.gov (United States)

    Radich, Allison; Garrett, P.; Jigmeddorj, B.; Michetti-Wilson, J.; Diaz Varela, A.; Hadinia, B.; Bianco, L.; Wong, J.; Chagnon-Lessard, S.; Dunlop, R.; Finlay, P.; Laffoley, A.; Leach, K. G.; Rand, E.; Sumithrarachchi, C.; Svennson, C. E.; Wood, J. L.; Yates, S. W.; Andreoiu, C.; Starosta, K.; Cross, D.; Garnsworthy, A. B.; Hackman, G.; Ball, G.; Triambak, S.

    2013-10-01

    The 124Xe nucleus has been thought to obey O(6) symmetry but a recent Coulomb excitation study has found that while O(5) may be preserved, O(6) appears to be badly broken. To further characterize the structure of this nucleus, a beta-decay experiment was performed at the TRIUMF-ISAC facility. A beam of radioactive 124Cs at a rate of 9.8 × 107 ions/s was implanted at the center of the 8Pi spectrometer where it underwent β + /EC decay into stable 124Xe. High-statistics gamma-gamma coincidence measurements have been analyzed to add to the level scheme of 124Xe, which has been extended considerably. The high statistics data set has revealed a new decay branch from a 124Cs high-spin isomer as well as several very-weak transitions between low-spin states in 124Xe. Branching ratios and B(E2) transition strengths have been calculated for the updated level scheme. The results will be important in determining collective properties and nuclear structure of the 124Xe.

  10. 136 Xe enrichment through cryogenic distillation

    Energy Technology Data Exchange (ETDEWEB)

    Back, Henning O.; Bottenus, Daniel R.; Clayton, Christopher K.; Stephenson, David E.; TeGrotenhuis, Ward E.

    2017-09-01

    The next generation of 136Xe neutrinoless double beta decay experiments will require on the order of 5 tons of enriched 136Xe. By estimating the relative volatilities of the xenon isotopes and using standard chemical engineering techniques we explore the feasibility of using cryogenic distillation to produce 5 tons of 80% enriched 136Xe in 5-6 years. With current state-of-the-art distillation column packing materials we can estimate the total height of a traditional cryogenic distillation column. We also, report on how Micro Channel Distillation may reduce the overall size of a distillation system for 136Xe production.

  11. Filling and Recycling Apparatus of a Cyclotron Target with Enriched Krypton for Production of Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    M. Vognar

    2001-01-01

    Full Text Available An apparatus for multiple filling of a cyclotron target with enriched Kr gas is described. The system is based on recycling pressurized gas by cryogenic pumping between the target tube and storage containers. The design and construction makes use of previous experience in the construction and operation of two analogue apparatuses for Xe124 high pressure gas targets, but major modifications have been incorporated, evoked by the different physical properties of Kr, by the character of the nuclear reaction, and by the demand for automation from the side of the end user.

  12. Design of Solid Form Xenon-124 Target for Producing I-123 Radioisotope Using Computer Simulation Techniques

    International Nuclear Information System (INIS)

    Kamali Moghaddam, K.; Sadeghi, M.; Kakavand, T.; Shokri Bonab, S.

    2006-01-01

    Recently in Cyclotron and Nuclear Medicine Department of NRCAM, at Atomic Energy organization of Iran (AEOI), a system for producing 1-123 via Xe-124 gas target technology, has been constructed and installed. One of the major problems in this system is the highly expensive cost of the enriched Xenon-124 gas. Therefore, saving this gas inside the system is very important. Unfortunately, by accidental rupture of the window foil or bad function of O-rings, the whole Xenon gas will escape from the system immediately. In this paper, by using computer codes; ALICE91, SRIM and doing some calculations we are going to demonstrate our latest effort for feasibility study of producing I-123 with the above mentioned reactions, but using Xe-124 solid target instead. According to our suggested design, a conical shaped irradiation vessel made of copper with 1 mm thickness, 1 cm outlet diameter, 5 cm length and 12 deg. angle at summit can be fixed inside a liquid nitrogen housing chamber. The Xenon-124 gas will be sent to the inside of this very cold conical trap and eventually deposited on its surface in solid form. Our calculation shows that during bombardment with 17-28 MeV proton energy, the thickness of solidified Xenon layer will remain around .28 mm. Likewise; thermo-dynamical calculation shows that in order to prevent the evaporation of solidified Xenon, the maximum permissible proton beam current for this system should be less than 1.4 μA. According to these working conditions, the production yield of I-123 can be predicted to be around 150 mCi/μAh. (authors)

  13. Ground-state and pairing-vibrational bands with equal quadrupole collectivity in 124Xe

    Science.gov (United States)

    Radich, A. J.; Garrett, P. E.; Allmond, J. M.; Andreoiu, C.; Ball, G. C.; Bianco, L.; Bildstein, V.; Chagnon-Lessard, S.; Cross, D. S.; Demand, G. A.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Hackman, G.; Hadinia, B.; Jigmeddorj, B.; Laffoley, A. T.; Leach, K. G.; Michetti-Wilson, J.; Orce, J. N.; Rajabali, M. M.; Rand, E. T.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Wang, Z. M.; Wood, J. L.; Wong, J.; Williams, S. J.; Yates, S. W.

    2015-04-01

    The nuclear structure of 124Xe has been investigated via measurements of the β+/EC decay of 124Cs with the 8 π γ -ray spectrometer at the TRIUMF-ISAC facility. The data collected have enabled branching ratio measurements of weak, low-energy transitions from highly excited states, and the 2+→0+ in-band transitions have been observed. Combining these results with those from a previous Coulomb excitation study, B (E 2 ;23+→02+) =78 (13 ) W.u. and B (E 2 ;24+→03+) =53 (12 ) W.u. were determined. The 03+ state, in particular, is interpreted as the main fragment of the proton-pairing vibrational band identified in a previous 122Te (3He,n )124Xe measurement, and has quadrupole collectivity equal to, within uncertainty, that of the ground-state band.

  14. Deep-inelastic scattering in 124,136Xe+58,64Ni at energies near the Coulomb barrier

    International Nuclear Information System (INIS)

    Gehring, J.; Back, B.B.; Chan, K.C.; Freer, M.; Henderson, D.; Jiang, C.L.; Rehm, K.E.; Schiffer, J.P.; Wolanski, M.; Wuosmaa, A.H.; Gehring, J.; Wolanski, M.

    1997-01-01

    Cross sections, angular distributions, and mass distributions have been measured for deep-inelastic scattering in 124 Xe+ 58 Ni and 136 Xe+ 64 Ni at laboratory energies in the vicinity of the Coulomb barrier. The mass distributions show distinct components due to deep-inelastic and fissionlike processes. The strength of deep-inelastic scattering is similar in the two systems measured and comparable to previous measurements in 58 Ni+ 112,124 Sn. copyright 1997 The American Physical Society

  15. Production of 125I from amorphous films of Si doped with 124Xe and evaluation of its potential use in brachytherapy

    International Nuclear Information System (INIS)

    Leal, Alexandre S.; Viana, Gustavo A.

    2015-01-01

    This work describes the simulation of a new material that can be used in the brachytherapy treatment. The material consists of xenon-incorporated amorphous silicon (Xe@a-Si). The irradiated 124 Xe atoms of the samples are converted into 125 Xe, according to the reaction: 124 Xe (n,γ) 125 Xe that, in turn, decays to the radioisotope 125 I. A set of simulations performed using the MCNP5 code, shows that, in principle, the material proposed can be used in the seed of brachytherapy in the clinical treatment. (author)

  16. Preparation and dosimetry of reactor-produced Xe-125 for ventilation scintigraphy

    International Nuclear Information System (INIS)

    Junker, D.; Cordes, H.

    1978-01-01

    Xe-125 is produced in the reactor by the (n, γ)-reaction from Xe-124. The natural abundance of Xe-124, however, is only 0,1 percent. As the costs for Xe-124 enriched Xenon are considerable, natural Xenon is activated in the epithermal energy region. In contrast to the other stable isotopes of Xenon, Xe-124 shows a large resonance cross section in this energy region. The main activation product is Xe-125. In addition, a few nuclides (e.g. Xe-125m, Xe-127m, Xe-137) are produced, which due to their short half lives give no contribution to radiation dose. Radiocontaminants originating from parent-daughter decay (e.g. Cs-135 and Cs-137) are separated by filtration of the gas. I-125 produced by the decay of Xe-125 is removed by filtering of the gas before administration to the patient. Typical yields of a sample capsule are 20 to 30 mCi Xe-125 after irradiation of 4 hours in an epithermal flux of approximately 2.10 -11 s -1 cm -2 . The residual contaminants contributing to the radiation dose are Xe-135 and Xe-129m. Depending on the irradiation time they amount to a few percent of the total activity. Using Xe-125 for lung ventilation studies results in considerable reduction of radiation dose as compared to Xe-133. An additional advantage is the better tissue penetration of Xe-125 (γ-energies at 188 keV (55%) and 243 keV (29%)) permitting the reduction of the dose for a study. The daughter nuclide I-125 generated during the study causes only a few mrem of radiation dose if the thyroid is blocked. Altogether Xe-125 as compared to Xe-133 offers more suitable γ-energies for lung ventilation studies and in addition a reduced radiation dose to the patient. (author)

  17. Study of important parameters on the irradiation of {sup 124}Xe, to improve the production of {sup 123}I with high purity using the Cyclone-30 cyclotron at IPEN-CNEN/SP; Estudo de parametros relevantes na irradiacao de {sup 124}Xe, visando a otimizacao na obtencao de {sup 123}I ultra puro no ciclotron Cyclone-30 do IPEN-CNEN/SP

    Energy Technology Data Exchange (ETDEWEB)

    Sumiya, Luiz Carlos do Amaral

    2006-07-01

    The development of diagnosis equipment and therapy procedures in nuclear medicine depends on the availability of commercial radioisotopes. IPEN is the most important institution that provides radioisotopes for national market. In order to achieve this function, IPEN had invested in the acquisition of a 30 MeV Cyclone-30 cyclotron to produce mainly {sup 18}F, {sup 67}Ga, {sup 201}Tl and {sup 123}I. The {sup 123}I production is the aim of the present work. With the {sup 123}I routine production data obtained by proton irradiation of Xe targets with an enrichment greater than 99.8%, it was possible to identify the important parameters that have direct influence on the production yield of high purity degree {sup 123}I. Even though the methodology for the commercial production of {sup 123}I, there are an scarcity of operational parameters data for this task. In this work the evaluated parameters were: {sup 124}Xe pressure, proton beam quality, irradiation time, operational temperature of the irradiation system under irradiation, waiting time to obtain {sup 123}I, temperature of washing solution and the impact of the internal Ni coating in the target. With the obtained results it was possible to modify the operational conditions for routine production and increasing the efficiency in about 30%. (author)

  18. High-spin {gamma}-ray spectroscopy of {sup 124}Ba, {sup 124}Xe and {sup 125}Xe

    Energy Technology Data Exchange (ETDEWEB)

    Al-Khatib, Ali

    2008-08-18

    rotational bands loose collectivity and, finally, when all nucleons outside the core have their spins aligned, the bands terminate. In the framework of this thesis, extensive spectroscopic investigations of three nuclei of the A {proportional_to}125 region, {sup 124}Ba, {sup 124}Xe and {sup 125}Xe, have been performed. These nuclei have been studied with the largest spectrometers available, Euroball and Gammasphere. The previously known level schemes of these nuclei have been extended substantially, both in the low- and high-spin regions. Many new rotational bands could be established. Lifetimes have been measured for several of the long large-deformation bands. The rotational structures, shape co-existence and band termination at high spins have been investigated. (orig.)

  19. Study of important parameters on the irradiation of 124Xe, to improve the production of 123I with high purity using the Cyclone-30 cyclotron at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Sumiya, Luiz Carlos do Amaral

    2006-01-01

    The development of diagnosis equipment and therapy procedures in nuclear medicine depends on the availability of commercial radioisotopes. IPEN is the most important institution that provides radioisotopes for national market. In order to achieve this function, IPEN had invested in the acquisition of a 30 MeV Cyclone-30 cyclotron to produce mainly 18 F, 67 Ga, 201 Tl and 123 I. The 123 I production is the aim of the present work. With the 123 I routine production data obtained by proton irradiation of Xe targets with an enrichment greater than 99.8%, it was possible to identify the important parameters that have direct influence on the production yield of high purity degree 123 I. Even though the methodology for the commercial production of 123 I, there are an scarcity of operational parameters data for this task. In this work the evaluated parameters were: 124 Xe pressure, proton beam quality, irradiation time, operational temperature of the irradiation system under irradiation, waiting time to obtain 123 I, temperature of washing solution and the impact of the internal Ni coating in the target. With the obtained results it was possible to modify the operational conditions for routine production and increasing the efficiency in about 30%. (author)

  20. Search of 2K(2ν) capture in 78 Kr and 124 Xe by means of wall-less proportional counters

    International Nuclear Information System (INIS)

    Volchenko, G.V.; Gavrilyuk, Yu.M.; Kuz'minov, V.V.; Osetrova, N.Ya.; Ratkevich, S.S.

    1998-01-01

    The technique of the experiment on the double two-neutrino K-capture search in isotopes of rare gases 78 Kr and 124 Xe is described. Multiwire wall-less proportional counters of a large volume are used in this experiment. Methods of decreasing the counter background noise in the energy range 10-100 keV are considered. These methods are based on the discrimination of events on the coordinate along the anode filament and the pulse rise time. The sensitivity of the experimental installation is estimated according to the half-life 78 Kr (1.2 x 10 21 years) and 124 Xe (2.6 x 10 20 years) with respect to the 2K(2ν) capture (68% certain level)

  1. A technique for searching for the 2 K capture in 124Xe with a copper proportional counter

    Science.gov (United States)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Kazalov, V. V.; Kuzminov, V. V.; Panasenko, S. I.; Ratkevich, S. S.; Tekueva, D. A.; Yakimenko, S. P.

    2015-12-01

    An experimental technique for searching for the 2 K capture in 124Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 107 relative to that at the Earth's surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of 124Xe with respect to the 2 K capture is set at the level of 2.5 × 1021 years.

  2. Search for 136Xe neutrinoless double beta decay with the Enriched Xenon Observatory (EXO)

    International Nuclear Information System (INIS)

    Giroux, G.

    2014-01-01

    The EXO collaboration is searching for the neutrinoless double beta decay of 136 Xe. Such observation would determine an absolute mass scale for the neutrinos, establish their Majorana nature, and uncover physics beyond the Standard Model. The EXO-200 detector is a single phase liquid xenon ultra low background TPC (Time Projection Chamber), with an active mass of 110 kg of 80.6% enriched xenon in the isotope 136. The detector is currently operating at the WIPP site and has been collecting data with enriched xenon since May 2011. The data collected give a lower limit for the neutrinoless double beta decay half-life of 136 Xe: T > 1.6*10 25 years at 90% C.L. The same data give a lower limit for the 2 neutrinos double beta decay of 136 Xe: T > 2.23*10 21 years that agrees with experimental values found in the literature

  3. A technique for searching for the 2K capture in {sup 124}Xe with a copper proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Kazalov, V. V.; Kuzminov, V. V. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation); Panasenko, S. I.; Ratkevich, S. S. [Karazin Kharkiv National University (Ukraine); Tekueva, D. A., E-mail: t.jami.a@mail.ru; Yakimenko, S. P. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation)

    2015-12-15

    An experimental technique for searching for the 2K capture in {sup 124}Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 10{sup 7} relative to that at the Earth’s surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of {sup 124}Xe with respect to the 2K capture is set at the level of 2.5 × 10{sup 21} years.

  4. Search for two-neutrino double electron capture on 124Xe with the XMASS-I detector

    Directory of Open Access Journals (Sweden)

    K. Abe

    2016-08-01

    Full Text Available Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on 124Xe is performed using 165.9 days of data collected with the XMASS-I liquid xenon detector. No significant excess above background was observed and we set a lower limit on the half-life as 4.7×1021 years at 90% confidence level. The obtained limit has ruled out parts of some theoretical expectations. We obtain a lower limit on the 126Xe two-neutrino double electron capture half-life of 4.3×1021 years at 90% confidence level as well.

  5. A new {sup 124}Xe irradiation system for {sup 123}I routine production at the 30 MeV IPEN-CNEN/SP cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Lapolli, André L.; Barcellos, Henrique; Matsuda, Hylton; Sumiya, Luiz C. do A.; Junqueira, Fernando de C., E-mail: alapolli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Since 2001 the Nuclear and Energy Research Institute (IPEN/CNEN-SP, Brazil) has produced about 2.5 mCi/μAh of {sup 123}I weekly using a manual irradiation system fully developed by its researchers. Ultrapure {sup 123}I has been produced and distributed to hospitals and clinics where several diagnostic imaging procedures are done for thyroid, brain and cardiovascular functions. Due to the short half-life and emission of low-energy photons, this radioisotope becomes suitable for diagnosis in children. Currently IPEN researchers are involved in the development of a new fully automated irradiation system dedicated to {sup 123}I routine production employing enriched xenon gas ({sup 124}Xe) as the target material. This new system consists of a target port, a water and a helium cooling system, a cryogenic system, an electric power system, a control and process monitoring unit composed of a supervisory software connected to a Programmable Logic Controller (PLC) via personal computer. In this new concept, there is no need for human interference during radioisotope production, reducing the possibility of eventual failures or incidents involving radioactive material. In this way, with this new system, a specific yield of approximately 3.5 mCi/μAh per irradiation is expected and this will meet a large part of the national demand for this important radioisotope. In the present work will be presented all the technical and constructive aspects of this new system as well as the results obtained in the irradiation of tests. (author)

  6. Light charged clusters emitted in 32 MeV/nucleon Xe,124136+Sn,112124 reactions: Chemical equilibrium and production of 3He and 6He

    Science.gov (United States)

    Bougault, R.; Bonnet, E.; Borderie, B.; Chbihi, A.; Dell'Aquila, D.; Fable, Q.; Francalanza, L.; Frankland, J. D.; Galichet, E.; Gruyer, D.; Guinet, D.; Henri, M.; La Commara, M.; Le Neindre, N.; Lombardo, I.; Lopez, O.; Manduci, L.; Marini, P.; Pârlog, M.; Roy, R.; Saint-Onge, P.; Verde, G.; Vient, E.; Vigilante, M.; Indra Collaboration

    2018-02-01

    Background: The isovector part of the nuclear equation of state remains partly unknown and is the subject of many studies. The degree of equilibration between the two main collision partners in heavy ion reactions may be used to study the equation of state since it is connected to isospin (N /Z ) transport properties of nuclear matter. Purpose: We aim to test chemical equilibrium attainment by measuring isotopic characteristics of emitted elements as a function of impact parameter. Method: We study four Xe,124136+Sn,112124 reactions at 32 MeV/nucleon. The data were acquired with the INDRA detector at the GANIL (Caen, France) facility. Combined (projectile+target) systems are identical for two studied reactions, therefore it is possible to study the path towards chemical equilibrium from different neutron to proton ratio (N /Z ) entrance channels. The study is limited to identified isotopes detected in the forward part of the center of mass in order to focus on the evolution of projectile-like fragment isotopic content and the benefit of excellent detection performances of the forward part of the apparatus. Results: Light charged particle productions, multiplicities, and abundance ratios dependence against impact parameter are studied. It is measured to almost identical mean characteristics for the two 124Xe+124Sn and 136Xe+112Sn systems for central collisions. Comparing all four studied systems it is shown that mean values evolve from projectile N /Z to projectile+target N /Z dependence. Those identical mean characteristics concern all light charged particles except 3He whose mean behavior is strongly different. Conclusions: Our inclusive analysis (no event selection) shows that N /Z equilibration between the projectile-like and the target-like is realized to a high degree for central collisions. The light charged particle production mean value difference between 124Xe+124Sn and 136Xe+112Sn systems for central collisions is of the order of a few %. This slight

  7. [Preparation, quality control and thyroid molecule imaging of solid-target based radionuclide ioine-124].

    Science.gov (United States)

    Zhu, H; Wang, F; Guo, X Y; Li, L Q; Duan, D B; Liu, Z B; Yang, Z

    2018-04-18

    To provide useful information for the further production and application of this novel radio-nuclide for potential clinical application. 124 Te (p,n) 124 I nuclide reaction was used for the 124 I production. Firstly, the target material, 124 TeO 2 (200 mg) and Al2O3 (30 mg) mixture, were compressed into the round platinum based solid target by tablet device. HM-20 medical cyclotron was applied to irradiate the solid target slice for 6-10 h with helium and water cooling. Then, the radiated solid target was placed for 12 h (overnight) to decay the radioactive impurity; finally, 124 I was be purified by dry distillation using 1 mL/min nitrogen for about 6 hours and radiochemical separation methods. Micro-PET imaging studies were performed to investigate the metabolism properties and thyroid imaging ability of 124 I.After 740 kBq 124 I was injected intravenously into the tail vein of the normal mice, the animals were imaged with micro-PET and infused with CT. The micro-PET/CT infusion imaging revealed actual state 124 I's metabolism in the mice. It was been successfully applied for 200 mg 124 TeO 2 plating by the tablet device on the surface of platinum. It showed smooth, dense surface and without obviously pits and cracks. The enriched 124 Te target was irradiated for 6 to 10 hours at about 12.0 MeV with 20 μA current on HM-20 cyclotron. Then 370-1 110 MBq 124 I could be produced on the solid target after irradiation and 370-740 MBq high specific activity could be collected afterdry distillation separation and radio-chemical purification. 124 I product was finally dissolved in 0.01 mol/L NaOH for the future distribution. The gamma spectrum of the produced 124 I-solution showed that radionuclide purity was over 80.0%. The micro-PET imaging of 124 I in the normal mice exhibited the thyroid and stomach accumulations and kidney metabolism, the bladder could also be clearly visible, which was in accordance with what was previously reported. To the best of our knowledge

  8. A new "1"2"4Xe irradiation system for "1"2"3I routine production at the 30 MeV IPEN-CNEN/SP cyclotron

    International Nuclear Information System (INIS)

    Lapolli, André L.; Barcellos, Henrique; Matsuda, Hylton; Sumiya, Luiz C. do A.; Junqueira, Fernando de C.

    2017-01-01

    Since 2001 the Nuclear and Energy Research Institute (IPEN/CNEN-SP, Brazil) has produced about 2.5 mCi/μAh of "1"2"3I weekly using a manual irradiation system fully developed by its researchers. Ultrapure "1"2"3I has been produced and distributed to hospitals and clinics where several diagnostic imaging procedures are done for thyroid, brain and cardiovascular functions. Due to the short half-life and emission of low-energy photons, this radioisotope becomes suitable for diagnosis in children. Currently IPEN researchers are involved in the development of a new fully automated irradiation system dedicated to "1"2"3I routine production employing enriched xenon gas ("1"2"4Xe) as the target material. This new system consists of a target port, a water and a helium cooling system, a cryogenic system, an electric power system, a control and process monitoring unit composed of a supervisory software connected to a Programmable Logic Controller (PLC) via personal computer. In this new concept, there is no need for human interference during radioisotope production, reducing the possibility of eventual failures or incidents involving radioactive material. In this way, with this new system, a specific yield of approximately 3.5 mCi/μAh per irradiation is expected and this will meet a large part of the national demand for this important radioisotope. In the present work will be presented all the technical and constructive aspects of this new system as well as the results obtained in the irradiation of tests. (author)

  9. Primordial Terrestrial Xe from the Viewpoint of CFF-Xe

    Science.gov (United States)

    Meshik, A. P.; Shukolyukov, Yu. A.; Jessberger, E. K.

    1995-09-01

    We have already reported [7, 23] on the non-linear isotope mass-fractionation of fission Xe by migration of the precursors I, Te, Sn, and Sb and simultaneous fission of heavy nuclei. Xe with anomalous isotopic pattern was found in a number of meteorites and terrestrial materials and was named CFF-Xe (Chemically Fractionated Fission Xe). It is characterized by an up eightfold ^132Xe and ^131Xe excesses coupled with smaller ^134Xe and ^129Xe excesses. The present work is aimed to estimate the role of CFF-Xe in the terrestrial lithosphere and specifically deals with the problem of the isotopic composition of primordial terrestrial Xe. Due to variations of the migration conditions the isotopic structure of CFF-Xe is not well established and is even not reproducible in the same rock [2]. Nevertheless, we have tried to estimate the composition of CFF-Xe by investigating all available isotopic data of Xe of presumable mantle origin. This is Xe in MORB [29, 1, 12] and ocean island glasses [1, 28], in diamonds [17], in volcanic rocks [29, 8, 9, 21], in volcanic glasses from pillow basalts [16, 6], continental igneous rocks [1, 24, 10, 22], carbonatites and granitoids [1] as well as Xe in natural gases [3, 24, 11, 4, 15]. All data are plotted Fig. 1 where we also suggest end members of the observed scattering. Optimized slopes of CFF-lines are shown as well as the position of the initial points which we regard as primordial terrestrial Xe (Xe0). The isotopic composition of CFF-Xe and Xe0 are given in Tab. 1. The abundances of ^124Xe and ^126Xe in mantle derived samples are very uncertain, but since ^128Xe/^130Xe in Xea and Xe0 is very similar we propose the same ^124Xe/^130Xe and ^126Xe/^130Xe ratios for both Xea and Xe0. If so, AVCC-Xe is simply Xe0 with an admixture of L-Xe, and atmospheric xenon Xea consists of Xe0, CFF-Xe and a small amount of fission Xe (92.5%Xe0 + 5.3%CFF-Xe + 2.2%XeF). Thus, a number of old problems in xenology are removed. The hypothetic components U-Xe

  10. Targeted Molecular Imaging of Cancer Cells Using MS2-Based 129 Xe NMR

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Keunhong [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Netirojjanakul, Chawita [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Munch, Henrik K. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Sun, Jinny [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Finbloom, Joel A. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Wemmer, David E. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Physical Biosciences Division; Pines, Alexander [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Francis, Matthew B. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division

    2016-07-25

    Targeted, selective, and highly sensitive 129Xe NMR nanoscale biosensors have been synthesized using a spherical MS2 viral capsid, Cryptophane A molecules, and DNA aptamers. The biosensors showed strong binding specificity toward targeted lymphoma cells (Ramos line). Hyperpolarized 129Xe NMR signal contrast and hyper-CEST 129Xe MRI image contrast indicated its promise as highly sensitive hyperpolarized 129Xe NMR nanoscale biosensor for future applications in cancer detection in vivo.

  11. (e, 2e) processes on Ne, Ar and Xe targets

    Energy Technology Data Exchange (ETDEWEB)

    Purohit, G; Patidar, Vinod; Sud, K K, E-mail: g_vpurohit@yahoo.co, E-mail: ghanshyam.purohit@spsu.ac.i [Department of Physics, School of Engineering, Sir Padampat Singhania University, Bhatewar, Udaipur-313 601 (India)

    2010-06-01

    Recently, there have been several attempts to explain the features of triple differential cross section (TDCS) for the (e, 2e) processes on inert targets Ne, Ar and Xe but there are still certain discrepancies in theoretical results and measurements, which require more theoretical efforts to understand the collision dynamics of these targets. We present in this paper the results of our modified distorted wave Born approximation (DWBA) calculation of TDCS for the ionization of Ne (2p), Ar (3p) and Xe (5p) targets. We modify the standard DWBA formalism by including the correlation-polarization potential (which is function of electron density) and compare our computed results with the available experimental and theoretical data. We observe that the polarization potential is able to improve the agreement with experimental results.

  12. Neutron Inelastic Scattering on 134Xe at En = 5 - 8 MeV

    Science.gov (United States)

    Kidd, Mary; Tornow, Werner; Finch, Sean; Krishichayan, Fnu; Bhike, Megha

    2017-09-01

    Neutrinoless double-beta decay (0 νββ) studies are both the best way to determine the Majorana nature of the neutrino and determine its effective mass. The two main experiments searching for 0 νββ -decay of 136Xe (Q value = 2457.8 keV) are Kamland-Zen and EXO-200. Though both experiments have enriched 136Xe targets, these targets still contain significant quantities of 134Xe. Recently, a new nuclear level was discovered in 134Xe that decays to the ground state emitting a 2485.7 keV gamma ray. The γ-ray production cross section for this branch was found to be on the order of 10 mb for incident neutron energies of 2.5-4.5 MeV. Here, we have extended the investigation of this level to higher incident neutron energies, and further explore the potential neutron-induced backgrounds on both 134Xe and 136Xe for extended neutron energies. We will report our preliminary results for neutron inelastic scattering on 134Xe in applications to 0 νββ decay searches. NSF PHY-1614348, DE-FG02-97ER41033.

  13. TARGET EXCITATION IN BARE ION XE/AR COLLISIONS STUDIED BY ELECTRON TARGET ION COINCIDENCES

    NARCIS (Netherlands)

    DENIJS, G; HOEKSTRA, R; MORGENSTERN, R

    We present electron spectra resulting from collisions of bare ions N-15(7+) and C-13(6+) on Ar and the charge state distribution of target ions resulting from C-13(6+)-Xe collisions. From both type of experiments we find evidence that electron capture accompanied by target excitation is an important

  14. Analysis of 125Xe electron-photon coincidence decay

    International Nuclear Information System (INIS)

    Klingberg, F.J.; Biegalski, S.R.

    2016-01-01

    As part of the verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), environmental gas samples originating from nuclear fission are analyzed for the presence of 131m Xe, 133m Xe, 133 Xe, and 135 Xe. In this work, the non-traditional radioxenon isotope 125 Xe was investigated. The isotope was produced as an isotopically pure sample via neutron activation of 124 Xe at the University of Texas at Austin Nuclear Engineering Teaching Lab's TRIGA MARK II Reactor. The sample was then measured using a HPGe detector as well as an ARSA-style b-c coincidence detector. Potential sources and sensitivities for production of 125 Xe are also considered for relevance to the CTBT verification mission. (author)

  15. Wavelengths and energy levels of Xe V and Xe VI obtained by collision-based spectroscopy

    International Nuclear Information System (INIS)

    Larsson, M.O.; Gonzalez, A.M.; Hallin, R.; Heijkenskjoeld, F.; Nystroem, B.; O'Sullivan, G.; Weber, C.; Waennstroem, A.

    1996-01-01

    We have utilized collision-based spectroscopy to investigate the spectra of Xe V and Xe VI. The radiation emitted following electron capture by 50 keV Xe 5+ and 60 keV Xe 6+ ions impinging on a He (Ar) gas target has been recorded in the 350-6000 (1200-2500) A wavelength region. A number of new energy levels of Xe V and Xe VI have been established from lines identified by us. In particular, we have observed and identified transitions from the 5s 2 5p4f (5s 2 4f) configuration of Xe V (Xe VI). The analysis was supported by Hartree-Fock calculations. (orig.)

  16. Experimental study of xenon isotopes production by gas centrifuge

    International Nuclear Information System (INIS)

    Zhou Mingsheng; Liang Xiongwen; Zhang Yonggang; Dong Jinping

    2006-01-01

    The gas centrifuge technology is studied for the separation of Xe isotopes. The nature Xe is chosen as processing gas. A four-state cascade is designed to separate 124 Xe to a concentration of being greater than 65% in three separation runs. 124 Xe can be enriched to a concentration 99% in more separation runs using a cascade of more gas centrifuges. (authors)

  17. Neurophysiological defects and neuronal gene deregulation in Drosophila mir-124 mutants.

    Directory of Open Access Journals (Sweden)

    Kailiang Sun

    2012-02-01

    Full Text Available miR-124 is conserved in sequence and neuronal expression across the animal kingdom and is predicted to have hundreds of mRNA targets. Diverse defects in neural development and function were reported from miR-124 antisense studies in vertebrates, but a nematode knockout of mir-124 surprisingly lacked detectable phenotypes. To provide genetic insight from Drosophila, we deleted its single mir-124 locus and found that it is dispensable for gross aspects of neural specification and differentiation. On the other hand, we detected a variety of mutant phenotypes that were rescuable by a mir-124 genomic transgene, including short lifespan, increased dendrite variation, impaired larval locomotion, and aberrant synaptic release at the NMJ. These phenotypes reflect extensive requirements of miR-124 even under optimal culture conditions. Comparison of the transcriptomes of cells from wild-type and mir-124 mutant animals, purified on the basis of mir-124 promoter activity, revealed broad upregulation of direct miR-124 targets. However, in contrast to the proposed mutual exclusion model for miR-124 function, its functional targets were relatively highly expressed in miR-124-expressing cells and were not enriched in genes annotated with epidermal expression. A notable aspect of the direct miR-124 network was coordinate targeting of five positive components in the retrograde BMP signaling pathway, whose activation in neurons increases synaptic release at the NMJ, similar to mir-124 mutants. Derepression of the direct miR-124 target network also had many secondary effects, including over-activity of other post-transcriptional repressors and a net incomplete transition from a neuroblast to a neuronal gene expression signature. Altogether, these studies demonstrate complex consequences of miR-124 loss on neural gene expression and neurophysiology.

  18. MiR-124 suppresses cell proliferation in hepatocellular carcinoma by targeting PIK3CA

    International Nuclear Information System (INIS)

    Lang, Qingbo; Ling, Changquan

    2012-01-01

    Highlights: ► PIK3CA is a novel target of miR-124 in HepG2 cells. ► MiR-124 suppresses cell proliferation by downregulating PIK3CA expression. ► MiR-124 regulates the PI3K/Akt pathway in HepG2 cells. ► MiR-124 overexpression inhibits the tumorigenesis in nude mice. -- Abstract: MicroRNAs (miRNAs) have crucial roles in the development and progression of human cancers, including hepatocellular carcinoma (HCC). Recent studies have shown that microRNA-124 (miR-124) was downregulated in HCC; however, the underlying mechanisms by which miR-124 suppresses tumorigenesis in HCC are largely unknown. In this study, we report that phosphoinositide 3-kinase catalytic subunit alpha (PIK3CA) is a novel target of miR-124 in HepG2 cells. Overexpression of miR-124 resulted in decreased expression of PIK3CA at both mRNA and protein levels. We found that miR-124 overexpression markedly suppressed cell proliferation by inducing G1-phase cell-cycle arrest in vitro. Consistent with the restoring miR-124 expression, PIK3CA knockdown suppressed cell proliferation, whereas overexpression of PIK3CA abolished the suppressive effect of miR-124. Mechanistic studies showed that miR-124-mediated reduction of PIK3CA resulted in suppression of PI3K/Akt pathway. The expressions of Akt and mTOR, key components of the PI3K/Akt pathway, were all downregulated. Moreover, we found overexpressed miR-124 effectively repressed tumor growth in xenograft animal experiments. Taken together, our results demonstrate that miR-124 functions as a growth-suppressive miRNA and plays an important role in inhibiting the tumorigenesis through targeting PIK3CA.

  19. MiR-124 suppresses cell proliferation in hepatocellular carcinoma by targeting PIK3CA

    Energy Technology Data Exchange (ETDEWEB)

    Lang, Qingbo [Department of Traditional Chinese Medicine, Changhai Hospital, Second Military Medical University, Shanghai 200433 (China); Ling, Changquan, E-mail: lingchangquan@hotmail.com [Department of Traditional Chinese Medicine, Changhai Hospital, Second Military Medical University, Shanghai 200433 (China)

    2012-09-21

    Highlights: Black-Right-Pointing-Pointer PIK3CA is a novel target of miR-124 in HepG2 cells. Black-Right-Pointing-Pointer MiR-124 suppresses cell proliferation by downregulating PIK3CA expression. Black-Right-Pointing-Pointer MiR-124 regulates the PI3K/Akt pathway in HepG2 cells. Black-Right-Pointing-Pointer MiR-124 overexpression inhibits the tumorigenesis in nude mice. -- Abstract: MicroRNAs (miRNAs) have crucial roles in the development and progression of human cancers, including hepatocellular carcinoma (HCC). Recent studies have shown that microRNA-124 (miR-124) was downregulated in HCC; however, the underlying mechanisms by which miR-124 suppresses tumorigenesis in HCC are largely unknown. In this study, we report that phosphoinositide 3-kinase catalytic subunit alpha (PIK3CA) is a novel target of miR-124 in HepG2 cells. Overexpression of miR-124 resulted in decreased expression of PIK3CA at both mRNA and protein levels. We found that miR-124 overexpression markedly suppressed cell proliferation by inducing G1-phase cell-cycle arrest in vitro. Consistent with the restoring miR-124 expression, PIK3CA knockdown suppressed cell proliferation, whereas overexpression of PIK3CA abolished the suppressive effect of miR-124. Mechanistic studies showed that miR-124-mediated reduction of PIK3CA resulted in suppression of PI3K/Akt pathway. The expressions of Akt and mTOR, key components of the PI3K/Akt pathway, were all downregulated. Moreover, we found overexpressed miR-124 effectively repressed tumor growth in xenograft animal experiments. Taken together, our results demonstrate that miR-124 functions as a growth-suppressive miRNA and plays an important role in inhibiting the tumorigenesis through targeting PIK3CA.

  20. New spectroscopic results in Xe II, Xe III, and Xe IV

    OpenAIRE

    Reyna Almandos, Jorge Guillermo; Gallardo, Mario; Garavaglia, Mario J.

    1982-01-01

    New results obtained in spontaneous xenon spectrum employing a conventional pulsed gaseous laser tube as light source, are presented in this work. A total of 626 spectral lines has been ionically assigned as follows: 50 to Xe II spectrum, 103 to Xe III spectrum, arid 222 to Xe IV spectrum. 30 Lines previously assigned to Xe II were reassigned as belonging to Xe III, 94 lines were assigned with some doubts to Xe II-III spectrum and 84 lines to Xe Ill-IV spectrum. Also there were clas...

  1. Ionization energies of Xe2+ and Xe3+

    International Nuclear Information System (INIS)

    Dutil, R.; Marmet, P.

    1980-01-01

    New electron impact measurements show that the previously accepted energies of ionization of Xe 2+ and Xe 3+ from xenon are erroneous. These energies are determined 33.11 +- 0.04 eV for Xe 2+ and 64.35 +- 0.10 eV for Xe 3+ . New structures are seen by electron impact just above the Xe 2+ threshold. New information is also given on the ionization energies of Xe 4+ and Xe 5+ . (orig.)

  2. On the study of proton-irradiated Tellurium targets relevant for production of medical radioisotopes 123I and 124I

    International Nuclear Information System (INIS)

    Imam Kambali; Hari Suryanto; Daya Agung Sarwono; Cahyana Amiruddin

    2014-01-01

    The energy loss distribution and range of energetic proton beams in tellurium (Te) target have been simulated using the Stopping and Range of Ion in Matter (SRIM 2013) codes. The calculated data of the proton's range were then used to determine the optimum thickness of Te targets for future production of 123 I and 124 I from 123 Te(p,n) 123 I, 124 Te(p,n) 124 I and 124 Te(p,2n) 123 I nuclear reactions using the BATAN's Cs-30 cyclotron. It was found that for an incidence angle of 0° with respect to the target normal, the optimum thickness of 123 Te and 124 Te targets for 123 I production should be 644 µm and 1.8 mm respectively, whereas a 649 µm thick 124 Te target would be Required for 124 I production. In addition, the thickness should be decreased with increasing incidence angle. The EOB yield could theoretically reach up to 13.62 Ci of 123 I at proton energy of 22 Me V and beam current of 30 µA if the 124 Te is irradiated over a period of 3 hours. The theoretical EOB yield is comparable to the experimental data with accuracy within 10%. (author)

  3. MicroRNA-124-3p expression and its prospective functional pathways in hepatocellular carcinoma: A quantitative polymerase chain reaction, gene expression omnibus and bioinformatics study.

    Science.gov (United States)

    He, Rong-Quan; Yang, Xia; Liang, Liang; Chen, Gang; Ma, Jie

    2018-04-01

    The present study aimed to explore the potential clinical significance of microRNA (miR)-124-3p expression in the hepatocarcinogenesis and development of hepatocellular carcinoma (HCC), as well as the potential target genes of functional HCC pathways. Reverse transcription-quantitative polymerase chain reaction was performed to evaluate the expression of miR-124-3p in 101 HCC and adjacent non-cancerous tissue samples. Additionally, the association between miR-124-3p expression and clinical parameters was also analyzed. Differentially expressed genes identified following miR-124-3p transfection, the prospective target genes predicted in silico and the key genes of HCC obtained from Natural Language Processing (NLP) were integrated to obtain potential target genes of miR-124-3p in HCC. Relevant signaling pathways were assessed with protein-protein interaction (PPI) networks, Gene Ontology (GO) enrichment analysis, Kyoto Encyclopedia of Genes and Genomes (KEGG) and Protein Annotation Through Evolutionary Relationships (PANTHER) pathway enrichment analysis. miR-124-3p expression was significantly reduced in HCC tissues compared with expression in adjacent non-cancerous liver tissues. In HCC, miR-124-3p was demonstrated to be associated with clinical stage. The mean survival time of the low miR-124-3p expression group was reduced compared with that of the high expression group. A total of 132 genes overlapped from differentially expressed genes, miR-124-3p predicted target genes and NLP identified genes. PPI network construction revealed a total of 109 nodes and 386 edges, and 20 key genes were identified. The major enriched terms of three GO categories included regulation of cell proliferation, positive regulation of cellular biosynthetic processes, cell leading edge, cytosol and cell projection, protein kinase activity, transcription activator activity and enzyme binding. KEGG analysis revealed pancreatic cancer, prostate cancer and non-small cell lung cancer as the

  4. Study on decay of 118Xe and 119Xe by means of mass-separator on-line with a synchrocyclotron

    International Nuclear Information System (INIS)

    Berlovich, Eh.E.; Batist, L.Kh.; Blinnikov, Yu.S.

    1976-01-01

    The decay of sup(118, 119)Xe isotopes has been investigated. An experimental device involving a mass-separator operating in line with a synchrocyclotron is briefly outlined. The elements to be investigated were isolated from a proton-irradiated target by the 'on-beam-chemistry' methods and transferred into the mass-separator ion source. The Xe separated ions are transported to detectors in an experimental ha ll. The energies and relative γ ray intensities of 118 Xe → 118 J and of 119 Xe → 119 J decays ar presented. The error of the γ ray energy determination does not exceed 0.6 keV. Obtained are the periods of half-life: for 118 Xe - (3.8+-0.9) min, for 119 Xe - (5.8+-0.3) min. The decay scheme for 119 Xe is made up. The scheme of 119 Xe levels is well inscribed into the general systematics of the J odd isotope levels. On the basis of obtained and known data the spin values are described to the 119 J levels

  5. Symmetries of Quadrupole-Collective Vibrational Motion in Transitional Even-Even 124−134Xenon Nuclei

    CERN Document Server

    Pietralla, N; Rainovski, G; Ahn, T; Bauer, C; Leske, J; Möller, O; Möller, T

    2010-01-01

    Projectile-Coulomb excitation of Xe isotopes has been performed at ANL using the Gammasphere array for the detection of γ-rays. The one-quadrupole phonon 2+ 1,ms mixed-symmetry state (MSS) has been traced in the stable N=80 isotones down to 134Xe. First, the data on absolute E2 andM1 transition rates quantify the amount of F-spin symmetry in these nuclei and provide a new local measure for the pn-QQ interaction. Second, the evolution of the 2+ 1,ms state has been studied along the sequence of stable even-even 124−134Xe isotopes that are considered to form a shape transition path from vibrational nuclei with vibrational U(5) symmetry near N=82 to γ-softly deformed shapes with almost O(6) symmetry. Third, our data on more than 50 absolute E2 transition rates between off-yrast low-spin states of 124,126Xe enable us to quantitatively test O(6) symmetry in these nuclei. As a result we find that O(6) symmetry is more strongly broken in the A=130 mass region than previously thought. The data will be discussed.

  6. Echo-planar MR imaging of dissolved hyperpolarized 129Xe. Potential for M angiography

    International Nuclear Information System (INIS)

    Maansson, S.

    2002-01-01

    Purpose: The feasibility of hyperpolarized 129 Xe for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique. Material and Methods: Hyperpolarized Xe gas was dissolved in ethanol; a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured. Results: The relaxation times of hyperpolarized Xe in ethanol were measured to T1=160±11 s and T2 ≅ 20 s. The resulting images of the flowing liquid were of reasonable quality and had an SNR of about 70. Conclusion: Based on the SNR of the obtained Xe EPI images; it was estimated that rapid in vivo MRA with 129 Xe may be feasible; provided that an efficient; biologically acceptable carrier for Xe can be found and polarization levels of more than 25% can be achieved in isotopically enriched 129 Xe

  7. miR-124-3p functions as a tumor suppressor in breast cancer by targeting CBL

    International Nuclear Information System (INIS)

    Wang, Yanbo; Chen, Luxiao; Wu, Zhenyu; Wang, Minghai; Jin, Fangfang; Wang, Nan; Hu, Xiuting; Liu, Zhengya; Zhang, Chen-Yu; Zen, Ke; Chen, Jiangning; Liang, Hongwei; Zhang, Yujing; Chen, Xi

    2016-01-01

    The origin and development of breast cancer remain complex and obscure. Recently, microRNA (miRNA) has been identified as an important regulator of the initiation and progression of breast cancer, and some studies have shown the essential role of miR-124-3p as a tumor suppressor in breast tumorigenesis. However, the detailed role of miR-124-3p in breast cancer remains poorly understood. Quantitative RT-PCR and western blotting assays were used to measure miR-124-3p and CBL expression levels in breast cancer tissues, respectively. Luciferase reporter assay was employed to validate the direct targeting of CBL by miR-124-3p. Cell proliferation and invasion assays were performed to analyze the biological functions of miR-124-3p and CBL in breast cancer cells. In the present study, we found that miR-124-3p was consistently downregulated in breast cancer tissues. Moreover, we showed that miR-124-3p significantly suppressed the proliferation and invasion of breast cancer cells. In addition, we investigated the molecular mechanism through which miR-124-3p contributes to breast cancer tumorigenesis and identified CBL (Cbl proto-oncogene, E3 ubiquitin protein ligase) as a direct target gene of miR-124-3p. Moreover, we found that ectopic expression of CBL can attenuate the inhibitory effect of miR-124-3p on cell proliferation and invasion in breast cancer cells. This study identified a new regulatory axis in which miR-124-3p and CBL regulate the proliferation and invasion of breast cancer cells. The online version of this article (doi:10.1186/s12885-016-2862-4) contains supplementary material, which is available to authorized users

  8. Search for double beta decay processes of {sup 124}Xe with XENON100 and XENON1T

    Energy Technology Data Exchange (ETDEWEB)

    Fieguth, Alexander [IKP, Westfaelische-Wilhelms-Universitaet Muenster (Germany)

    2016-07-01

    Driven by the search for dark matter particles the XENON dark matter project recently installed its next stage multi-ton experiment XENON1T at the LNGS, which will probe the spin-indpendent-WIMP-Nucleon cross section down to 2.10{sup -47} cm{sup 2}. Besides its main purpose different particle physics topics can be addressed by the taken data. One example are the double beta decay processes of natural isotope {sup 124}Xe. This isotope is expected to decay via two-neutrino double electron capture (2νECEC) and due to its high Q-value of 2864 keV additionally through 2νβ{sup +}β{sup +}. Since these processes have not been detected so far, there is only a lower limit the respective half-life (e.g. > 4.7.10{sup 21} yr for 2νECEC). A detection of the 2νECEC is possible using XENON1T data by looking for its clear signature of secondary X-rays or Auger electrons and at least new lower half-life limits for all other decay channels can be obtained. While these processes are expected from standard model physics, a detection of a decay without neutrinos (e.g 0νECEC) would hint towards beyond the standard model physics and could derive conclusions on the neutrino mass. Until XENON1T is taking data, the search for all processes can be tested in the recorded data of its predecessor XENON100.

  9. Multicollector High Precision Resolution of Primordial Kr and Xe in Mantle CO2 Well Gases

    Science.gov (United States)

    Holland, G.; Ballentine, C.; Cassidy, M.

    2008-12-01

    Noble gas isotopes in magmatic CO2 well gases provide a unique insight into mantle volatile origin and dynamics [1-3]. Previous work has resolved mantle 20Ne/22Ne ratios consistent with a solar wind irradiated meteoritic source for mantle He and Ne [1]. This is distinct from Solar Wind values that might be expected if the primary mechanism of terrestrial mantle volatile acquisition was through the gravitational capture of solar nebula gases [see 4]. Within the CO2 well gases a primordial component has also been resolved in the non- radiogenic Xe isotopic composition [2,3]. Using multicollector mass spectrometry we have observed a 124Xe/130Xe excess of 1.85 percent over air plus/minus 0.17 percent for the least air contaminated samples. At this level of precision we are for the first time able to differentiate between a trapped meteoritic origin (average carbonaceous chondrite or Q Xe) rather than Solar Wind origin as the primordial Xe component. The well gases also contain Kr which, in the least air contaminated sample, have a correlated 86Kr/82Kr excess of 0.55 percent over air plus/minus 0.04 percent. Whilst mass dependent fractionation can theoretically produce correlated excesses in 124Xe-128Xe and 82Kr-86Kr isotopes, no fractionation from air is observed in 38Ar/36Ar [3] and the Kr excesses are in the opposite sense to that of Xe. From 136Xe excesses, Kr fission yield from Pu and U can be calculated and subtracted from the Kr isotopic signature. This fission-corrected signature is most reasonably explained as a primordial component. This is the first time that primordial Kr has ever been resolved in a terrestrial sample. The primordial Kr isotopic signature is distinct from Solar Wind Kr and is consistent with the primordial Kr also originating as a trapped component within meteorites. We are now able to demonstrate that both the light (He and Ne) and Heavy (Kr and Xe) noble gas origin in the terrestrial mantle is consistent with a trapped component during the

  10. Flow measurements in biological systems using Xe-127 and Xe-133

    International Nuclear Information System (INIS)

    Tripathi, R.R.

    1981-01-01

    Xe-133 and Xe-127 are widely used for quantitative evaluation of ventilation in human subjects. Owing to differences in scattering in the biological system as well as differences in the detector response to photons of selected energies, clinical Xe-133 images are much more distorted than the corresponding Xe-127 images. This thesis concerns itself with the evaluation of Xe-133 and Xe-127 as potential tracers for pulmonary function studies. Through the simulation of clinical images it is shown that such smaller abnormalities are able to be detected with Xe-127 than with Xe-133. It is also found that even for poorly ventilated regions, the measured lesion size in the simulated image is comparable to the known lesion size when studied with Xe-127. With Xe-133, however, the measured size of the lesion is smaller than its known size. By fitting the washout portion of the clinical data to a linear sum of two exponentials, a weighted average clearance constant for the tracer - which relates to the reciprocal of the mean flow through the system - can be calculated and used as an index for comparison of the two Xenon isotopes. When an appropriate model is used for data interpretation, more accurate clinical information can be derived from the Xe-127 data. Unlike Xe-133, ventilation study with Xe-127 can be performed immediately after the perfusion study with Tc-99m. Lower radiation dose and longer shelf-life of Xe-127 are added advantages over Xe-133. Various compartmental and non-compartmental models are examined and appropriate technique(s) for clinical data interpretation is(are) recommended

  11. Argentina technical report

    International Nuclear Information System (INIS)

    2002-01-01

    At present, the Production Cyclotron Facility, installed at the Ezeiza Atomic Centre, is used for Tl-201 production; F-18 and I-123 production will be incorporated during this year. Concerning I-123 production, a system for irradiation of gaseous target has been developed in the frame of the IAEA Technical Assistance Project (ARG4085). The iodine production system delivers an ultra pure radioisotope via nuclear reactions: 124 Xe (p,2n) 123 Cs → 123 Xe → 123 I and 124 Xe (p,pn) 123 Xe → 123 I. This report describes the target and irradiation chamber design, the radiochemical purification process

  12. Characteristics of functional enrichment and gene expression level of human putative transcriptional target genes.

    Science.gov (United States)

    Osato, Naoki

    2018-01-19

    Transcriptional target genes show functional enrichment of genes. However, how many and how significantly transcriptional target genes include functional enrichments are still unclear. To address these issues, I predicted human transcriptional target genes using open chromatin regions, ChIP-seq data and DNA binding sequences of transcription factors in databases, and examined functional enrichment and gene expression level of putative transcriptional target genes. Gene Ontology annotations showed four times larger numbers of functional enrichments in putative transcriptional target genes than gene expression information alone, independent of transcriptional target genes. To compare the number of functional enrichments of putative transcriptional target genes between cells or search conditions, I normalized the number of functional enrichment by calculating its ratios in the total number of transcriptional target genes. With this analysis, native putative transcriptional target genes showed the largest normalized number of functional enrichments, compared with target genes including 5-60% of randomly selected genes. The normalized number of functional enrichments was changed according to the criteria of enhancer-promoter interactions such as distance from transcriptional start sites and orientation of CTCF-binding sites. Forward-reverse orientation of CTCF-binding sites showed significantly higher normalized number of functional enrichments than the other orientations. Journal papers showed that the top five frequent functional enrichments were related to the cellular functions in the three cell types. The median expression level of transcriptional target genes changed according to the criteria of enhancer-promoter assignments (i.e. interactions) and was correlated with the changes of the normalized number of functional enrichments of transcriptional target genes. Human putative transcriptional target genes showed significant functional enrichments. Functional

  13. Anisotropic flow in Xe-Xe collisions at 5.44 TeV

    CERN Document Server

    Acharya, Shreyasi; The ALICE collaboration; Adamova, Dagmar; Adolfsson, Jonatan; Aggarwal, Madan Mohan; Aglieri Rinella, Gianluca; Agnello, Michelangelo; Agrawal, Neelima; Ahammed, Zubayer; Ahn, Sang Un; Aiola, Salvatore; Akindinov, Alexander; Al-turany, Mohammad; Alam, Sk Noor; Silva De Albuquerque, Danilo; Aleksandrov, Dmitry; Alessandro, Bruno; Alfaro Molina, Jose Ruben; Ali, Yasir; Alici, Andrea; Alkin, Anton; Alme, Johan; Alt, Torsten; Altenkamper, Lucas; Altsybeev, Igor; Anaam, Mustafa Naji; Andrei, Cristian; Andreou, Dimitra; Andrews, Harry Arthur; Andronic, Anton; Angeletti, Massimo; Anguelov, Venelin; Anson, Christopher Daniel; Anticic, Tome; Antinori, Federico; Antonioli, Pietro; Anwar, Rafay; Apadula, Nicole; Aphecetche, Laurent Bernard; Appelshaeuser, Harald; Arcelli, Silvia; Arnaldi, Roberta; Arnold, Oliver Werner; Arsene, Ionut Cristian; Arslandok, Mesut; Audurier, Benjamin; Augustinus, Andre; Averbeck, Ralf Peter; Azmi, Mohd Danish; Badala, Angela; Baek, Yong Wook; Bagnasco, Stefano; Bailhache, Raphaelle Marie; Bala, Renu; Baldisseri, Alberto; Ball, Markus; Baral, Rama Chandra; Barbano, Anastasia Maria; Barbera, Roberto; Barile, Francesco; Barioglio, Luca; Barnafoldi, Gergely Gabor; Barnby, Lee Stuart; Ramillien Barret, Valerie; Bartalini, Paolo; Barth, Klaus; Bartsch, Esther; Bastid, Nicole; Basu, Sumit; Batigne, Guillaume; Batyunya, Boris; Batzing, Paul Christoph; Bazo Alba, Jose Luis; Bearden, Ian Gardner; Beck, Hans; Bedda, Cristina; Behera, Nirbhay Kumar; Belikov, Iouri; Bellini, Francesca; Bello Martinez, Hector; Bellwied, Rene; Espinoza Beltran, Lucina Gabriela; Belyaev, Vladimir; Bencedi, Gyula; Beole, Stefania; Bercuci, Alexandru; Berdnikov, Yaroslav; Berenyi, Daniel; Bertens, Redmer Alexander; Berzano, Dario; Betev, Latchezar; Bhaduri, Partha Pratim; Bhasin, Anju; Bhat, Inayat Rasool; Bhatt, Himani; Bhattacharjee, Buddhadeb; Bhom, Jihyun; Bianchi, Antonio; Bianchi, Livio; Bianchi, Nicola; Bielcik, Jaroslav; Bielcikova, Jana; Bilandzic, Ante; Biro, Gabor; Biswas, Rathijit; Biswas, Saikat; Blair, Justin Thomas; Blau, Dmitry; Blume, Christoph; Boca, Gianluigi; Bock, Friederike; Bogdanov, Alexey; Boldizsar, Laszlo; Bombara, Marek; Bonomi, Germano; Bonora, Matthias; Borel, Herve; Borissov, Alexander; Borri, Marcello; Botta, Elena; Bourjau, Christian; Bratrud, Lars; Braun-munzinger, Peter; Bregant, Marco; Broker, Theo Alexander; Broz, Michal; Brucken, Erik Jens; Bruna, Elena; Bruno, Giuseppe Eugenio; Budnikov, Dmitry; Buesching, Henner; Bufalino, Stefania; Buhler, Paul; Buncic, Predrag; Busch, Oliver; Buthelezi, Edith Zinhle; Bashir Butt, Jamila; Buxton, Jesse Thomas; Cabala, Jan; Caffarri, Davide; Caines, Helen Louise; Caliva, Alberto; Calvo Villar, Ernesto; Soto Camacho, Rabi; Camerini, Paolo; Capon, Aaron Allan; Carena, Francesco; Carena, Wisla; Carnesecchi, Francesca; Castillo Castellanos, Javier Ernesto; Castro, Andrew John; Casula, Ester Anna Rita; Ceballos Sanchez, Cesar; Chandra, Sinjini; Chang, Beomsu; Chang, Wan; Chapeland, Sylvain; Chartier, Marielle; Chattopadhyay, Subhasis; Chattopadhyay, Sukalyan; Chauvin, Alex; Cheshkov, Cvetan Valeriev; Cheynis, Brigitte; Chibante Barroso, Vasco Miguel; Dobrigkeit Chinellato, David; Cho, Soyeon; Chochula, Peter; Chowdhury, Tasnuva; Christakoglou, Panagiotis; Christensen, Christian Holm; Christiansen, Peter; Chujo, Tatsuya; Chung, Suh-urk; Cicalo, Corrado; Cifarelli, Luisa; Cindolo, Federico; Cleymans, Jean Willy Andre; Colamaria, Fabio Filippo; Colella, Domenico; Collu, Alberto; Colocci, Manuel; Concas, Matteo; Conesa Balbastre, Gustavo; Conesa Del Valle, Zaida; Contreras Nuno, Jesus Guillermo; Cormier, Thomas Michael; Corrales Morales, Yasser; Cortese, Pietro; Cosentino, Mauro Rogerio; Costa, Filippo; Costanza, Susanna; Crkovska, Jana; Crochet, Philippe; Cuautle Flores, Eleazar; Cunqueiro Mendez, Leticia; Dahms, Torsten; Dainese, Andrea; Dani, Sanskruti; Danisch, Meike Charlotte; Danu, Andrea; Das, Debasish; Das, Indranil; Das, Supriya; Dash, Ajay Kumar; Dash, Sadhana; De, Sudipan; De Caro, Annalisa; De Cataldo, Giacinto; De Conti, Camila; De Cuveland, Jan; De Falco, Alessandro; De Gruttola, Daniele; De Marco, Nora; De Pasquale, Salvatore; Derradi De Souza, Rafael; Franz Degenhardt, Hermann; Deisting, Alexander; Deloff, Andrzej; Delsanto, Silvia; Deplano, Caterina; Dhankher, Preeti; Di Bari, Domenico; Di Mauro, Antonio; Di Ruzza, Benedetto; Arteche Diaz, Raul; Dietel, Thomas; Dillenseger, Pascal; Ding, Yanchun; Divia, Roberto; Djuvsland, Oeystein; Dobrin, Alexandru Florin; Domenicis Gimenez, Diogenes; Donigus, Benjamin; Dordic, Olja; Van Doremalen, Lennart Vincent; Dubey, Anand Kumar; Dubla, Andrea; Ducroux, Laurent; Dudi, Sandeep; Duggal, Ashpreet Kaur; Dukhishyam, Mallick; Dupieux, Pascal; Ehlers Iii, Raymond James; Elia, Domenico; Endress, Eric; Engel, Heiko; Epple, Eliane; Erazmus, Barbara Ewa; Erhardt, Filip; Ersdal, Magnus Rentsch; Espagnon, Bruno; Eulisse, Giulio; Eum, Jongsik; Evans, David; Evdokimov, Sergey; Fabbietti, Laura; Faggin, Mattia; Faivre, Julien; Fantoni, Alessandra; Fasel, Markus; Feldkamp, Linus; Feliciello, Alessandro; Feofilov, Grigorii; Fernandez Tellez, Arturo; Ferretti, Alessandro; Festanti, Andrea; Feuillard, Victor Jose Gaston; Figiel, Jan; Araujo Silva Figueredo, Marcel; Filchagin, Sergey; Finogeev, Dmitry; Fionda, Fiorella; Fiorenza, Gabriele; Flor, Fernando; Floris, Michele; Foertsch, Siegfried Valentin; Foka, Panagiota; Fokin, Sergey; Fragiacomo, Enrico; Francescon, Andrea; Francisco, Audrey; Frankenfeld, Ulrich Michael; Fronze, Gabriele Gaetano; Fuchs, Ulrich; Furget, Christophe; Furs, Artur; Fusco Girard, Mario; Gaardhoeje, Jens Joergen; Gagliardi, Martino; Gago Medina, Alberto Martin; Gajdosova, Katarina; Gallio, Mauro; Duarte Galvan, Carlos; Ganoti, Paraskevi; Garabatos Cuadrado, Jose; Garcia-solis, Edmundo Javier; Garg, Kunal; Gargiulo, Corrado; Gasik, Piotr Jan; Gauger, Erin Frances; De Leone Gay, Maria Beatriz; Germain, Marie; Ghosh, Jhuma; Ghosh, Premomoy; Ghosh, Sanjay Kumar; Gianotti, Paola; Giubellino, Paolo; Giubilato, Piero; Glassel, Peter; Gomez Coral, Diego Mauricio; Gomez Ramirez, Andres; Gonzalez, Victor; Gonzalez Zamora, Pedro; Gorbunov, Sergey; Gorlich, Lidia Maria; Gotovac, Sven; Grabski, Varlen; Graczykowski, Lukasz Kamil; Graham, Katie Leanne; Greiner, Leo Clifford; Grelli, Alessandro; Grigoras, Costin; Grigoryev, Vladislav; Grigoryan, Ara; Grigoryan, Smbat; Gronefeld, Julius Maximilian; Grosa, Fabrizio; Grosse-oetringhaus, Jan Fiete; Grosso, Raffaele; Guernane, Rachid; Guerzoni, Barbara; Guittiere, Manuel; Gulbrandsen, Kristjan Herlache; Gunji, Taku; Gupta, Anik; Gupta, Ramni; Bautista Guzman, Irais; Haake, Rudiger; Habib, Michael Karim; Hadjidakis, Cynthia Marie; Hamagaki, Hideki; Hamar, Gergoe; Hamid, Mohammed; Hamon, Julien Charles; Hannigan, Ryan; Haque, Md Rihan; Harris, John William; Harton, Austin Vincent; Hassan, Hadi; Hatzifotiadou, Despina; Hayashi, Shinichi; Heckel, Stefan Thomas; Hellbar, Ernst; Helstrup, Haavard; Herghelegiu, Andrei Ionut; Gonzalez Hernandez, Emma; Herrera Corral, Gerardo Antonio; Herrmann, Florian; Hetland, Kristin Fanebust; Hilden, Timo Eero; Hillemanns, Hartmut; Hills, Christopher; Hippolyte, Boris; Hohlweger, Bernhard; Horak, David; Hornung, Sebastian; Hosokawa, Ritsuya; Hota, Jyotishree; Hristov, Peter Zahariev; Huang, Chun-lu; Hughes, Charles; Huhn, Patrick; Humanic, Thomas; Hushnud, Hushnud; Hussain, Nur; Hussain, Tahir; Hutter, Dirk; Hwang, Dae Sung; Iddon, James Philip; Iga Buitron, Sergio Arturo; Ilkaev, Radiy; Inaba, Motoi; Ippolitov, Mikhail; Islam, Md Samsul; Ivanov, Marian; Ivanov, Vladimir; Izucheev, Vladimir; Jacak, Barbara; Jacazio, Nicolo; Jacobs, Peter Martin; Jadhav, Manoj Bhanudas; Jadlovska, Slavka; Jadlovsky, Jan; Jaelani, Syaefudin; Jahnke, Cristiane; Jakubowska, Monika Joanna; Janik, Malgorzata Anna; Jena, Chitrasen; Jercic, Marko; Jevons, Oliver; Jimenez Bustamante, Raul Tonatiuh; Jin, Muqing; Jones, Peter Graham; Jusko, Anton; Kalinak, Peter; Kalweit, Alexander Philipp; Kang, Ju Hwan; Kaplin, Vladimir; Kar, Somnath; Karasu Uysal, Ayben; Karavichev, Oleg; Karavicheva, Tatiana; Karczmarczyk, Przemyslaw; Karpechev, Evgeny; Kebschull, Udo Wolfgang; Keidel, Ralf; Keijdener, Darius Laurens; Keil, Markus; Ketzer, Bernhard Franz; Khabanova, Zhanna; Khan, Ahsan Mehmood; Khan, Shaista; Khan, Shuaib Ahmad; Khanzadeev, Alexei; Kharlov, Yury; Khatun, Anisa; Khuntia, Arvind; Kielbowicz, Miroslaw Marek; Kileng, Bjarte; Kim, Byungchul; Kim, Daehyeok; Kim, Dong Jo; Kim, Eun Joo; Kim, Hyeonjoong; Kim, Jinsook; Kim, Jiyoung; Kim, Minjung; Kim, Se Yong; Kim, Taejun; Kim, Taesoo; Kirsch, Stefan; Kisel, Ivan; Kiselev, Sergey; Kisiel, Adam Ryszard; Klay, Jennifer Lynn; Klein, Carsten; Klein, Jochen; Klein-boesing, Christian; Klewin, Sebastian; Kluge, Alexander; Knichel, Michael Linus; Knospe, Anders Garritt; Kobdaj, Chinorat; Varga-kofarago, Monika; Kohler, Markus Konrad; Kollegger, Thorsten; Kondratyeva, Natalia; Kondratyuk, Evgeny; Konevskikh, Artem; Konyushikhin, Maxim; Kovalenko, Oleksandr; Kovalenko, Vladimir; Kowalski, Marek; Kralik, Ivan; Kravcakova, Adela; Kreis, Lukas; Krivda, Marian; Krizek, Filip; Kruger, Mario; Kryshen, Evgeny; Krzewicki, Mikolaj; Kubera, Andrew Michael; Kucera, Vit; Kuhn, Christian Claude; Kuijer, Paulus Gerardus; Kumar, Jitendra; Kumar, Lokesh; Kumar, Shyam; Kundu, Sourav; Kurashvili, Podist; Kurepin, Alexander; Kurepin, Alexey; Kuryakin, Alexey; Kushpil, Svetlana; Kvapil, Jakub; Kweon, Min Jung; Kwon, Youngil; La Pointe, Sarah Louise; La Rocca, Paola; Lai, Yue Shi; Lakomov, Igor; Langoy, Rune; Lapidus, Kirill; Lara Martinez, Camilo Ernesto; Lardeux, Antoine Xavier; Larionov, Pavel; Laudi, Elisa; Lavicka, Roman; Lea, Ramona; Leardini, Lucia; Lee, Seongjoo; Lehas, Fatiha; Lehner, Sebastian; Lehrbach, Johannes; Lemmon, Roy Crawford; Leon Monzon, Ildefonso; Levai, Peter; Li, Xiaomei; Li, Xing Long; Lien, Jorgen Andre; Lietava, Roman; Lim, Bong-hwi; Lindal, Svein; Lindenstruth, Volker; Lindsay, Scott William; Lippmann, Christian; Lisa, Michael Annan; Litichevskyi, Vladyslav; Liu, Alwina; Ljunggren, Hans Martin; Llope, William; Lodato, Davide Francesco; Loginov, Vitaly; Loizides, Constantinos; Loncar, Petra; Lopez, Xavier Bernard; Lopez Torres, Ernesto; Lowe, Andrew John; Luettig, Philipp Johannes; Luhder, Jens Robert; Lunardon, Marcello; Luparello, Grazia; Lupi, Matteo; Maevskaya, Alla; Mager, Magnus; Mahmood, Sohail Musa; Maire, Antonin; Majka, Richard Daniel; Malaev, Mikhail; Malik, Qasim Waheed; Malinina, Liudmila; Mal'kevich, Dmitry; Malzacher, Peter; Mamonov, Alexander; Manko, Vladislav; Manso, Franck; Manzari, Vito; Mao, Yaxian; Marchisone, Massimiliano; Mares, Jiri; Margagliotti, Giacomo Vito; Margotti, Anselmo; Margutti, Jacopo; Marin, Ana Maria; Markert, Christina; Marquard, Marco; Martin, Nicole Alice; Martinengo, Paolo; Martinez, Jacobb Lee; Martinez Hernandez, Mario Ivan; Martinez-garcia, Gines; Martinez Pedreira, Miguel; Masciocchi, Silvia; Masera, Massimo; Masoni, Alberto; Massacrier, Laure Marie; Masson, Erwann; Mastroserio, Annalisa; Mathis, Andreas Michael; Toledo Matuoka, Paula Fernanda; Matyja, Adam Tomasz; Mayer, Christoph; Mazzilli, Marianna; Mazzoni, Alessandra Maria; Meddi, Franco; Melikyan, Yuri; Menchaca-rocha, Arturo Alejandro; Meninno, Elisa; Mercado-perez, Jorge; Meres, Michal; Soncco Meza, Carlos; Mhlanga, Sibaliso; Miake, Yasuo; Micheletti, Luca; Mieskolainen, Matti Mikael; Mihaylov, Dimitar Lubomirov; Mikhaylov, Konstantin; Mischke, Andre; Mishra, Aditya Nath; Miskowiec, Dariusz Czeslaw; Mitra, Jubin; Mitu, Ciprian Mihai; Mohammadi, Naghmeh; Mohanty, Auro Prasad; Mohanty, Bedangadas; Khan, Mohammed Mohisin; Moreira De Godoy, Denise Aparecida; Perez Moreno, Luis Alberto; Moretto, Sandra; Morreale, Astrid; Morsch, Andreas; Muccifora, Valeria; Mudnic, Eugen; Muhlheim, Daniel Michael; Muhuri, Sanjib; Mukherjee, Maitreyee; Mulligan, James Declan; Gameiro Munhoz, Marcelo; Munning, Konstantin; Arratia Munoz, Miguel Ignacio; Munzer, Robert Helmut; Murakami, Hikari; Murray, Sean; Musa, Luciano; Musinsky, Jan; Myers, Corey James; Myrcha, Julian Wojciech; Naik, Bharati; Nair, Rahul; Nandi, Basanta Kumar; Nania, Rosario; Nappi, Eugenio; Narayan, Amrendra; Naru, Muhammad Umair; Nassirpour, Adrian Fereydon; Ferreira Natal Da Luz, Pedro Hugo; Nattrass, Christine; Rosado Navarro, Sebastian; Nayak, Kishora; Nayak, Ranjit; Nayak, Tapan Kumar; Nazarenko, Sergey; Negrao De Oliveira, Renato Aparecido; Nellen, Lukas; Nesbo, Simon Voigt; Neskovic, Gvozden; Ng, Fabian; Nicassio, Maria; Niedziela, Jeremi; Nielsen, Borge Svane; Nikolaev, Sergey; Nikulin, Sergey; Nikulin, Vladimir; Noferini, Francesco; Nomokonov, Petr; Nooren, Gerardus; Cabanillas Noris, Juan Carlos; Norman, Jaime; Nyanin, Alexander; Nystrand, Joakim Ingemar; Oh, Hoonjung; Ohlson, Alice Elisabeth; Oleniacz, Janusz; Oliveira Da Silva, Antonio Carlos; Oliver, Michael Henry; Onderwaater, Jacobus; Oppedisano, Chiara; Orava, Risto; Oravec, Matej; Ortiz Velasquez, Antonio; Oskarsson, Anders Nils Erik; Otwinowski, Jacek Tomasz; Oyama, Ken; Pachmayer, Yvonne Chiara; Pacik, Vojtech; Pagano, Davide; Paic, Guy; Palni, Prabhakar; Pan, Jinjin; Pandey, Ashutosh Kumar; Panebianco, Stefano; Papikyan, Vardanush; Pareek, Pooja; Park, Jonghan; Parkkila, Jasper Elias; Parmar, Sonia; Passfeld, Annika; Pathak, Surya Prakash; Patra, Rajendra Nath; Paul, Biswarup; Pei, Hua; Peitzmann, Thomas; Peng, Xinye; Pereira, Luis Gustavo; Pereira Da Costa, Hugo Denis Antonio; Peresunko, Dmitry Yurevich; Perez Lezama, Edgar; Peskov, Vladimir; Pestov, Yury; Petracek, Vojtech; Petrovici, Mihai; Petta, Catia; Peretti Pezzi, Rafael; Piano, Stefano; Pikna, Miroslav; Pillot, Philippe; Ozelin De Lima Pimentel, Lais; Pinazza, Ombretta; Pinsky, Lawrence; Pisano, Silvia; Piyarathna, Danthasinghe; Ploskon, Mateusz Andrzej; Planinic, Mirko; Pliquett, Fabian; Pluta, Jan Marian; Pochybova, Sona; Podesta Lerma, Pedro Luis Manuel; Poghosyan, Martin; Polishchuk, Boris; Poljak, Nikola; Poonsawat, Wanchaloem; Pop, Amalia; Poppenborg, Hendrik; Porteboeuf, Sarah Julie; Pozdniakov, Valeriy; Prasad, Sidharth Kumar; Preghenella, Roberto; Prino, Francesco; Pruneau, Claude Andre; Pshenichnov, Igor; Puccio, Maximiliano; Punin, Valery; Putschke, Jorn Henning; Raha, Sibaji; Rajput, Sonia; Rak, Jan; Rakotozafindrabe, Andry Malala; Ramello, Luciano; Rami, Fouad; Raniwala, Rashmi; Raniwala, Sudhir; Rasanen, Sami Sakari; Rascanu, Bogdan Theodor; Ratza, Viktor; Ravasenga, Ivan; Read, Kenneth Francis; Redlich, Krzysztof; Rehman, Attiq Ur; Reichelt, Patrick Simon; Reidt, Felix; Ren, Xiaowen; Renfordt, Rainer Arno Ernst; Reshetin, Andrey; Revol, Jean-pierre; Reygers, Klaus Johannes; Riabov, Viktor; Richert, Tuva Ora Herenui; Richter, Matthias Rudolph; Riedler, Petra; Riegler, Werner; Riggi, Francesco; Ristea, Catalin-lucian; Rode, Sudhir Pandurang; Rodriguez Cahuantzi, Mario; Roeed, Ketil; Rogalev, Roman; Rogochaya, Elena; Rohr, David Michael; Roehrich, Dieter; Rokita, Przemyslaw Stefan; Ronchetti, Federico; Dominguez Rosas, Edgar; Roslon, Krystian; Rosnet, Philippe; Rossi, Andrea; Rotondi, Alberto; Roukoutakis, Filimon; Roy, Christelle Sophie; Roy, Pradip Kumar; Vazquez Rueda, Omar; Rui, Rinaldo; Rumyantsev, Boris; Rustamov, Anar; Ryabinkin, Evgeny; Ryabov, Yury; Rybicki, Andrzej; Saarinen, Sampo; Sadhu, Samrangy; Sadovskiy, Sergey; Safarik, Karel; Saha, Sumit Kumar; Sahoo, Baidyanath; Sahoo, Pragati; Sahoo, Raghunath; Sahoo, Sarita; Sahu, Pradip Kumar; Saini, Jogender; Sakai, Shingo; Saleh, Mohammad Ahmad; Sambyal, Sanjeev Singh; Samsonov, Vladimir; Sandoval, Andres; Sarkar, Amal; Sarkar, Debojit; Sarkar, Nachiketa; Sarma, Pranjal; Sas, Mike Henry Petrus; Scapparone, Eugenio; Scarlassara, Fernando; Schaefer, Brennan; Scheid, Horst Sebastian; Schiaua, Claudiu Cornel; Schicker, Rainer Martin; Schmidt, Christian Joachim; Schmidt, Hans Rudolf; Schmidt, Marten Ole; Schmidt, Martin; Schmidt, Nicolas Vincent; Schukraft, Jurgen; Schutz, Yves Roland; Schwarz, Kilian Eberhard; Schweda, Kai Oliver; Scioli, Gilda; Scomparin, Enrico; Sefcik, Michal; Seger, Janet Elizabeth; Sekiguchi, Yuko; Sekihata, Daiki; Selyuzhenkov, Ilya; Senosi, Kgotlaesele; Senyukov, Serhiy; Serradilla Rodriguez, Eulogio; Sett, Priyanka; Sevcenco, Adrian; Shabanov, Arseniy; Shabetai, Alexandre; Shahoyan, Ruben; Shaikh, Wadut; Shangaraev, Artem; Sharma, Anjali; Sharma, Ankita; Sharma, Meenakshi; Sharma, Natasha; Sheikh, Ashik Ikbal; Shigaki, Kenta; Shimomura, Maya; Shirinkin, Sergey; Shou, Qiye; Shtejer Diaz, Katherin; Sibiryak, Yury; Siddhanta, Sabyasachi; Sielewicz, Krzysztof Marek; Siemiarczuk, Teodor; Silvermyr, David Olle Rickard; Simatovic, Goran; Simonetti, Giuseppe; Singaraju, Rama Narayana; Singh, Ranbir; Singh, Randhir; Singhal, Vikas; Sarkar - Sinha, Tinku; Sitar, Branislav; Sitta, Mario; Skaali, Bernhard; Slupecki, Maciej; Smirnov, Nikolai; Snellings, Raimond; Snellman, Tomas Wilhelm; Song, Jihye; Soramel, Francesca; Sorensen, Soren Pontoppidan; Sozzi, Federica; Sputowska, Iwona Anna; Stachel, Johanna; Stan, Ionel; Stankus, Paul; Stenlund, Evert Anders; Stocco, Diego; Storetvedt, Maksim Melnik; Strmen, Peter; Alarcon Do Passo Suaide, Alexandre; Sugitate, Toru; Suire, Christophe Pierre; Suleymanov, Mais Kazim Oglu; Suljic, Miljenko; Sultanov, Rishat; Sumbera, Michal; Sumowidagdo, Suharyo; Suzuki, Ken; Swain, Sagarika; Szabo, Alexander; Szarka, Imrich; Tabassam, Uzma; Takahashi, Jun; Tambave, Ganesh Jagannath; Tanaka, Naoto; Tarhini, Mohamad; Tariq, Mohammad; Tarzila, Madalina-gabriela; Tauro, Arturo; Tejeda Munoz, Guillermo; Telesca, Adriana; Terrevoli, Cristina; Teyssier, Boris; Thakur, Dhananjaya; Thakur, Sanchari; Thomas, Deepa; Thoresen, Freja; Tieulent, Raphael Noel; Tikhonov, Anatoly; Timmins, Anthony Robert; Toia, Alberica; Topilskaya, Nataliya; Toppi, Marco; Rojas Torres, Solangel; Tripathy, Sushanta; Trogolo, Stefano; Trombetta, Giuseppe; Tropp, Lukas; Trubnikov, Victor; Trzaska, Wladyslaw Henryk; Trzcinski, Tomasz Piotr; Trzeciak, Barbara Antonina; Tsuji, Tomoya; Tumkin, Alexandr; Turrisi, Rosario; Tveter, Trine Spedstad; Ullaland, Kjetil; Umaka, Ejiro Naomi; Uras, Antonio; Usai, Gianluca; Utrobicic, Antonija; Vala, Martin; Van Hoorne, Jacobus Willem; Van Leeuwen, Marco; Vande Vyvre, Pierre; Varga, Dezso; Diozcora Vargas Trevino, Aurora; Vargyas, Marton; Varma, Raghava; Vasileiou, Maria; Vasiliev, Andrey; Vauthier, Astrid; Vazquez Doce, Oton; Vechernin, Vladimir; Veen, Annelies Marianne; Vercellin, Ermanno; Vergara Limon, Sergio; Vermunt, Luuk; Vernet, Renaud; Vertesi, Robert; Vickovic, Linda; Viinikainen, Jussi Samuli; Vilakazi, Zabulon; Villalobos Baillie, Orlando; Villatoro Tello, Abraham; Vinogradov, Alexander; Virgili, Tiziano; Vislavicius, Vytautas; Vodopyanov, Alexander; Volkl, Martin Andreas; Voloshin, Kirill; Voloshin, Sergey; Volpe, Giacomo; Von Haller, Barthelemy; Vorobyev, Ivan; Voscek, Dominik; Vranic, Danilo; Vrlakova, Janka; Wagner, Boris; Wang, Hongkai; Wang, Mengliang; Watanabe, Yosuke; Weber, Michael; Weber, Steffen Georg; Wegrzynek, Adam; Weiser, Dennis Franz; Wenzel, Sandro Christian; Wessels, Johannes Peter; Westerhoff, Uwe; Whitehead, Andile Mothegi; Wiechula, Jens; Wikne, Jon; Wilk, Grzegorz Andrzej; Wilkinson, Jeremy John; Willems, Guido Alexander; Williams, Crispin; Willsher, Emily; Windelband, Bernd Stefan; Witt, William Edward; Xu, Ran; Yalcin, Serpil; Yamakawa, Kosei; Yano, Satoshi; Yin, Zhongbao; Yokoyama, Hiroki; Yoo, In-kwon; Yoon, Jin Hee; Yurchenko, Volodymyr; Zaccolo, Valentina; Zaman, Ali; Zampolli, Chiara; Correa Zanoli, Henrique Jose; Zardoshti, Nima; Zarochentsev, Andrey; Zavada, Petr; Zavyalov, Nikolay; Zbroszczyk, Hanna Paulina; Zhalov, Mikhail; Zhang, Xiaoming; Zhang, Yonghong; Zhang, Zuman; Zhao, Chengxin; Zherebchevskii, Vladimir; Zhigareva, Natalia; Zhou, Daicui; Zhou, You; Zhou, Zhuo; Zhu, Hongsheng; Zhu, Jianhui; Zhu, Ya; Zichichi, Antonino; Zimmermann, Markus Bernhard; Zinovjev, Gennady; Zmeskal, Johann; Zou, Shuguang

    2018-01-01

    The first measurements of anisotropic flow coefficients $v_{n}$ for mid-rapidity charged particles in Xe-Xe collisions at $\\sqrt{s_{NN}}=5.44$ TeV are presented. Comparing these measurements to those from Pb-Pb collisions at $\\sqrt{s_{NN}}=5.02$ TeV, $v_{2}$ is found to be suppressed for mid-central collisions at the same centrality, and enhanced for central collisions. The values of $v_{3}$ are generally larger in Xe-Xe than in Pb-Pb at a given centrality. These observations are consistent with expectations from hydrodynamic predictions. When both $v_{2}$ and $v_{3}$ are divided by their corresponding eccentricities for a variety of initial state models, they generally scale with transverse density when comparing Xe-Xe and Pb-Pb, with some deviations observed in central Xe-Xe and Pb-Pb collisions. These results assist in placing strong constraints on both the initial state geometry and medium response for relativistic heavy-ion collisions.

  14. The 4s- and 4p- XPS spectra of Xe, XeF2 and XeF4

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2003-01-01

    The 4s- and 4p- XPS spectra of Xe gas, XeF 2 molecule and XeF 4 molecule are calculated by an ab-initio atomic many-body theory. The 4s-peak and the prominent '4p'-peak are predicted well by the present theory. In XeF 2 and XeF 4 the spectral lines observed below the 4d-double ionization threshold are the 4d -2 4f multiplet states strongly perturbed by the interaction with the initial 4p 1/2 -hole state. They are very similar to the spectral lines which emerge with an increase in atomic number (e.g. Ba)

  15. Constraints on the timing of the Moon-forming giant impact from MORB Xe isotopes

    Science.gov (United States)

    Parai, R.; Mukhopadhyay, S.

    2014-12-01

    124,126,128,130Xe in the MORB source mantle; however, a high degree of Xe retention in the upper mantle throughout accretion is physically unlikely. We use Monte Carlo analysis to locate the parameter space that satisfies our I-Pu-U-Xe constraints and to thereby improve our age constraint on catastrophic outgassing triggered by the Moon-forming giant impact.

  16. Low enrichment Mo-99 target development program at ANSTO

    International Nuclear Information System (INIS)

    Donlevy, Therese M.; Anderson, Peter J.; Beattie, David; Braddock, Ben; Fulton, Scott; Godfrey, Robert; Law, Russell; McNiven, Scott; Sirkka, Pertti; Storr, Greg; Wassink, David; Wong, Alan; Yeoh, Guan

    2002-01-01

    The Australian Nuclear Science and Technology Organisation (ANSTO, formerly AAEC) has been producing fission product Mo-99 in HIFAR, from the irradiation of Low Enrichment Uranium (LEU) UO 2 targets, for nearly thirty years. Over this period, the U-235 enrichment has been increased in stages, from natural to 1.8% to 2.2%. The decision to provide Australia with a replacement research reactor (RRR) for HIFAR has created an ideal opportunity to review and improve the current Mo-99 production process from target design through to chemical processing and waste management options. ANSTO has entered into a collaboration with Argonne National Laboratory (RERTR) to develop a target using uranium metal foil with U-235 enrichment of less than 20% The initial focus has been to demonstrate use of LEU foil targets in HIFAR, using existing irradiation methodology. The current effort focussed on designing a target assembly with optimised thermohydraulic characteristics to accommodate larger LEU foils to meet Mo-99 production needs. The ultimate goal is to produce an LEU target suitable for use in the Replacement Research Reactor when it is commissioned in 2005. This paper reports our activities on: - The regulatory approval processes required in order to undertake irradiation of this new target; -Supporting calculations (neutronics, computational fluid dynamics) for safety submission; - Design challenges and changes to prototype irradiation; - Trial irradiation of LEU foil target in HIFAR; - Future target and rig development program at ANSTO. (author)

  17. Determination of 131mXe and 133mXe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; McIntyre, J.I.; Pitts, W.K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131m Xe, 133m Xe, 133g Xe, and 135g Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse-height spectra of gamma-energy versus beta-energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131m Xe. 133m Xe, and 133g Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (T 1/2 = 6.27 ns) between beta-particles from 133g Xe and conversion electrons depopulating the 81-keV state in 133 Cs is being developed. This technique allows separation of the 133g Xe beta spectrum from the conversion electrons due to 131m Xe and 133m Xe and uniquely quantifies all three nuclides. (author)

  18. Determination of 131m Xe and 133m Xe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, Paul L.; Bowyer, Ted W.; McIntyre, Justin I.; Pitts, W K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131mXe. 133mXe, and 133Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (t1/2 = 6.27 ns) between beta particles from 133Xe and conversion electrons depopulating the 81-keV state in 133Cs is being developed. This technique will allow separation of the 133Xe spectrum from the conversion electrons due to 131mXe and 133mXe and will uniquely quantify all three nuclides

  19. Low-lying levels of 129Xe and 131Xe

    International Nuclear Information System (INIS)

    Palmer, D.C.; Irving, A.D.; Forsyth, P.D.; Hall, I.; Martin, D.G.E.; Maynard, M.J.

    1978-01-01

    The nuclei 129 Xe and 131 Xe have been studied by Coulomb excitation and by (α, n) reactions on 126 Te and 128 Te. Eleven new levels for 129 Xe and six for 131 Xe and B(E2) transition values for some of the low-lying states are reported. The present Coulomb excitation experiments together with published β-decay work enable some spin-parity assignments and restrictions to be made. The data are broadly consistent with the predictions of the particle-vibrator coupling model, although a thorough comparison requires further spectroscopic measurements and more detailed theoretical calculation. (author)

  20. Availability of enriched isotopic material for accelerator targets

    International Nuclear Information System (INIS)

    Newman, E.

    1982-01-01

    The electromagnetic isotope enrichment facility at ORNL provides a broad spectrum of highly enriched stable isotopes to the worldwide scientific community. The continued timely availability of these materials is of vital importance in many areas of basic research and, in particular, as source material for the fabrication of accelerator targets. A brief description of the facility and its capabilities and limitations is presented

  1. Mung bean nuclease treatment increases capture specificity of microdroplet-PCR based targeted DNA enrichment.

    Directory of Open Access Journals (Sweden)

    Zhenming Yu

    Full Text Available Targeted DNA enrichment coupled with next generation sequencing has been increasingly used for interrogation of select sub-genomic regions at high depth of coverage in a cost effective manner. Specificity measured by on-target efficiency is a key performance metric for target enrichment. Non-specific capture leads to off-target reads, resulting in waste of sequencing throughput on irrelevant regions. Microdroplet-PCR allows simultaneous amplification of up to thousands of regions in the genome and is among the most commonly used strategies for target enrichment. Here we show that carryover of single-stranded template genomic DNA from microdroplet-PCR constitutes a major contributing factor for off-target reads in the resultant libraries. Moreover, treatment of microdroplet-PCR enrichment products with a nuclease specific to single-stranded DNA alleviates off-target load and improves enrichment specificity. We propose that nuclease treatment of enrichment products should be incorporated in the workflow of targeted sequencing using microdroplet-PCR for target capture. These findings may have a broad impact on other PCR based applications for which removal of template DNA is beneficial.

  2. Hydrodynamic predictions for 5.44 TeV Xe+Xe collisions

    Science.gov (United States)

    Giacalone, Giuliano; Noronha-Hostler, Jacquelyn; Luzum, Matthew; Ollitrault, Jean-Yves

    2018-03-01

    We argue that relativistic hydrodynamics is able to make robust predictions for soft particle production in Xe+Xe collisions at the CERN Large Hadron Collider (LHC). The change of system size from Pb+Pb to Xe+Xe provides a unique opportunity to test the scaling laws inherent to fluid dynamics. Using event-by-event hydrodynamic simulations, we make quantitative predictions for several observables: mean transverse momentum, anisotropic flow coefficients, and their fluctuations. Results are shown as a function of collision centrality.

  3. Production of highly charged ion beams Kr32+, Xe44+, Au54+ with Electron String Ion Source (ESIS) Krion-2 and corresponding basic and applied studies

    Science.gov (United States)

    Donets, D. E.; Donets, E. D.; Donets, E. E.; Salnikov, V. V.; Shutov, V. B.

    2010-09-01

    Electron String Ion Source (ESIS) Krion-2 (JINR, Dubna) was used for basic and applied research in various aspects of multiply charged heavy ions production. Energy recuperation mode in ESIS has been proofed first and used for production of highly charged ions 84Kr28+÷84Kr32+, 124Xe40÷124Xe44 and Au51+÷ Au54+. Krion-2 ESIS was mounted on high voltage (HV) platform of LU-20 Linac and used as an injector of highly charged ions during Nuclotron run N° 41. Krion-2 ESIS has produced 3.0.107 124Xe42+ ions per pulse of 7 μs duration. This ion beam was injected into LU-20 and Nuclotron, accelerated up to energy of 186 GeV and the extracted Xe beam was used for physics experiments. Electron String Ion Source Krion-2 demonstrated the high reliability and stability running during 30 days on HV platform. We believe that it is due to an extremely low electron beam power, provided by using the electron string mode of operation: 50 W pulse power and about 10 W average power. Other possible application of ESIS could be its use in injection complexes of synchrotrons and cyclotrons for cancer therapy. Slow and fast extraction of C4+ and C6+ beams from Krion-2 ESIS were preliminary studied towards ESIS optimization for medical accelerators requirements.

  4. Yield of 117Sb, 118mSb, 120mSb, 122Sb, 124Sb in reactions Sn (p, xn)

    International Nuclear Information System (INIS)

    Dmitriev, P.P.; Konstantinov, I.O.

    1993-01-01

    Yield of 117 Sb, 118m Sb, 120m Sb, 122 Sb, 124 Sb from thick target depending on proton energy is measured. The maximum proton energy is 21.7±0.2 MeV. Antimony isotopes yield in separate reactions when irradiating of tin isotopes with 100% enrichment is determined using the method published earlier. The methods for production of 117 Sb, 118m Sb, 120m Sb, 122 Sb, 124 Sb with high radioisotope purity are shown. 13 refs., 1 fig., 3 tabs

  5. 128Xe Lifetime Measurement Using the Coulex-Plunger Technique in Inverse Kinematics

    International Nuclear Information System (INIS)

    Konstantinopoulos, T.; Lagoyannis, A.; Harissopulos, S.; Dewald, A.; Rother, W.; Ilie, G.; Jones, P.; Rakhila, P.; Greenlees, P.; Grahn, T.; Julin, R.; Balabanski, D. L.

    2008-01-01

    The lifetimes of the lowest collective yrast and non-yrast states in 128 Xe were measured in a Coulomb excitation experiment using the recoil distance method (RDM) in inverse kinematics. Hereby, the Cologne plunger apparatus was employed together with the JUROGAM spectrometer. Excited states in 128 Xe were populated using a 128 Xe beam impinging on a nat Fe target with E( 128 Xe)≅525 MeV. Recoils were detected by means of an array of solar cells placed at forward angles. Recoil-gated γ-spectra were measured at different plunger distances

  6. 128Xe Lifetime Measurement Using the Coulex-Plunger Technique in Inverse Kinematics

    Science.gov (United States)

    Konstantinopoulos, T.; Lagoyannis, A.; Harissopulos, S.; Dewald, A.; Rother, W.; Ilie, G.; Jones, P.; Rakhila, P.; Greenlees, P.; Grahn, T.; Julin, R.; Balabanski, D. L.

    2008-05-01

    The lifetimes of the lowest collective yrast and non-yrast states in 128Xe were measured in a Coulomb excitation experiment using the recoil distance method (RDM) in inverse kinematics. Hereby, the Cologne plunger apparatus was employed together with the JUROGAM spectrometer. Excited states in 128Xe were populated using a 128Xe beam impinging on a natFe target with E(128Xe)~525 MeV. Recoils were detected by means of an array of solar cells placed at forward angles. Recoil-gated γ-spectra were measured at different plunger distances.

  7. Symmetric resonance double charge transfer in Kr++ + Kr and Xe++ + Xe systems

    International Nuclear Information System (INIS)

    Okuno, K.; Koizumi, T.; Kaneko, Y.

    1978-01-01

    Cross sections of processes Kr ++ + Kr → Ke + Kr ++ and Xe ++ + XeXe + Xe ++ were measured by the injected-ion-drift-tube technique from 0.04 to 20 eV. For both cases, the cross section below 1 eV coincides with the orbiting cross sections with a charge-transfer probability 1/2. Above 1 eV, the energy dependence of the cross sectcion is like that for single charge transfer. Mobilities of Kr ++ and Xe ++ in He are presented also

  8. Inner-shell photoionization and core-hole decay of Xe and XeF2.

    Science.gov (United States)

    Southworth, Stephen H; Wehlitz, Ralf; Picón, Antonio; Lehmann, C Stefan; Cheng, Lan; Stanton, John F

    2015-06-14

    Photoionization cross sections and partial ion yields of Xe and XeF2 from Xe 3d(5/2), Xe 3d(3/2), and F 1s subshells in the 660-740 eV range are compared to explore effects of the F ligands. The Xe 3d-ϵf continuum shape resonances dominate the photoionization cross sections of both the atom and molecule, but prominent resonances appear in the XeF2 cross section due to nominal excitation of Xe 3d and F 1s electrons to the lowest unoccupied molecular orbital (LUMO), a delocalized anti-bonding MO. Comparisons of the ion products from the atom and molecule following Xe 3d photoionization show that the charge-state distribution of Xe ions is shifted to lower charge states in the molecule along with production of energetic F(+) and F(2+) ions. This suggests that, in decay of a Xe 3d core hole, charge is redistributed to the F ligands and the system dissociates due to Coulomb repulsion. The ion products from excitation of the F 1s-LUMO resonance are different and show strong increases in the yields of Xe(+) and F(+) ions. The subshell ionization thresholds, the LUMO resonance energies, and their oscillator strengths are calculated by relativistic coupled-cluster methods and agree well with measurements.

  9. I-124 and its applications in nuclear medicine and biology

    International Nuclear Information System (INIS)

    Weinreich, R.; Wyer, L.; Crompton, N.; Nievergelt-Egido, M.C.; Guenther, I.; Roelcke, U.; Leenders, K.L.; Knust, E.J.; Blasberg, R.G.

    1998-01-01

    4.15-d 124 I decays simultaneously by positron emission (25.6 %) and by electron capture (74.4 %). This dualistic decay allows in principle to use 124 I in both diagnostic and therapeutic approaches. In some high-current measurements, 124 I was produced via the nuclear reaction 124 Te(p,n) 124 I using 12.6 MeV protons in yields 25% below those of the mainly used reaction 124 Te(d,2n) 124 I, but with a very much lower contamination by long-lived 125 I and 126 I. The minimum obtained value for the sum of all impurities was 0.14% of the 124 I activity, at 6 days after end of bombardment, using 99.8% enriched 124 TeO 2 as target material. This yield/purity ratio also permits the production of 124 I by low-energy ''baby'' cyclotrons which could considerably increase the general availability of this nuclide. [ 124 ]IUdR was synthesized by direct electrophilic labelling in good yield (45-65 %), high radiochemical purity (>95%) and high specific activity for functional PET imaging of brain tumours. One day after administration to patients and after completion of the ''washout'', the only remaining activity was that in tumour structures. The comparison with the tumour labelling index showed that PET with [ 124 ]IUdR introduces a novel imaging approach: tumour diagnostics by the measurement of cell proliferation. [ 124 ]IodoHoechst 33258 was synthesized by direct electrophilic labelling in yields of 70 % and in a radiochemical purity of 99 %. In cell culture experiments using HTB-40 (human adenocarcinoma line), it was shown to be taken up by the DNA as well as the unlabelled fluorescence dye H 33258. Furthermore, its radiobiological activity was equal to that of the 125 I-labelled H 33258, but markedly stronger than that of the 131 I-labelled derivative. This suggests a mechanism for Auger-electron induced radiobiological activity as a novel therapeutical approach. p-[ 124 ]Iodophenylalanine and [ 124 ]iodo-α-methyltyrosine are two other compounds labelled with 124 I that

  10. Hyb-Seq: combining target enrichment and genome skimming for plant phylogenomics

    Science.gov (United States)

    Kevin Weitemier; Shannon C.K. Straub; Richard C. Cronn; Mark Fishbein; Roswitha Schmickl; Angela McDonnell; Aaron. Liston

    2014-01-01

    • Premise of the study: Hyb-Seq, the combination of target enrichment and genome skimming, allows simultaneous data collection for low-copy nuclear genes and high-copy genomic targets for plant systematics and evolution studies. • Methods and Results: Genome and transcriptome assemblies for milkweed ( Asclepias syriaca ) were used to design enrichment probes for 3385...

  11. Low-enriched uranium high-density target project. Compendium report

    Energy Technology Data Exchange (ETDEWEB)

    Vandegrift, George; Brown, M. Alex; Jerden, James L.; Gelis, Artem V.; Stepinski, Dominique C.; Wiedmeyer, Stanley; Youker, Amanda; Hebden, Andrew; Solbrekken, G; Allen, C; Robertson., D; El-Gizawy, Sherif; Govindarajan, Srisharan; Hoyer, Annemarie; Makarewicz, Philip; Harris, Jacob; Graybill, Brian; Gunn, Andy; Berlin, James; Bryan, Chris; Sherman, Steven; Hobbs, Randy; Griffin, F. P.; Chandler, David; Hurt, C. J.; Williams, Paul; Creasy, John; Tjader, Barak; McFall, Danielle; Longmire, Hollie

    2016-09-01

    At present, most 99Mo is produced in research, test, or isotope production reactors by irradiation of highly enriched uranium targets. To achieve the denser form of uranium needed for switching from high to low enriched uranium (LEU), targets in the form of a metal foil (~125-150 µm thick) are being developed. The LEU High Density Target Project successfully demonstrated several iterations of an LEU-fission-based Mo-99 technology that has the potential to provide the world’s supply of Mo-99, should major producers choose to utilize the technology. Over 50 annular high density targets have been successfully tested, and the assembly and disassembly of targets have been improved and optimized. Two target front-end processes (acidic and electrochemical) have been scaled up and demonstrated to allow for the high-density target technology to mate up to the existing producer technology for target processing. In the event that a new target processing line is started, the chemical processing of the targets is greatly simplified. Extensive modeling and safety analysis has been conducted, and the target has been qualified to be inserted into the High Flux Isotope Reactor, which is considered above and beyond the requirements for the typical use of this target due to high fluence and irradiation duration.

  12. miR-124 suppresses proliferation and invasion of nasopharyngeal carcinoma cells through the Wnt/β-catenin signaling pathway by targeting Capn4

    Directory of Open Access Journals (Sweden)

    Hu H

    2017-05-01

    Full Text Available Haili Hu,1,* Guanghui Wang,1,* Congying Li2 1Department of Otorhinolaryngology, Huaihe Hospital of Henan University, 2Department of Otorhinolaryngology, School of Medicine, Kaifeng University, Kaifeng, People’s Republic of China *These authors contributed equally to this work Background: Recent studies have demonstrated that microRNA 124 (miR-124 acts as a tumor suppressor in nasopharyngeal carcinoma (NPC; however, the exact molecular mechanism by which miR-124 exerts tumor suppression has not been well elucidated.Materials and methods: We performed quantitative real-time PCR (qRT-PCR to measure the expression of metastasis associated lung adenocarcinoma transcript 1, miR-124, and calpain small subunit 1 (Capn4 mRNAs in NPC cell lines. We also performed western blot analysis to detect the levels of Capn4. Furthermore, we performed MTT assay and transwell invasion assay to determine the proliferation and invasion ability of two NPC cell lines, namely, HONE1 and CNE2 cells, respectively. The verification of targets of miR-124 was performed using prediction softwares and luciferase reporter analysis.Results: According to our results, the expression of Capn4 was found to be elevated, whereas the expression of miR-124 was lowered in NPC cell lines compared with normal nasopharyngeal cells. When we preformed overexpression of miR-124, it suppressed the proliferation and invasion of NPC cells. Moreover, miR-124 suppressed the expression of Capn4 by targeting Capn4 in HONE1 and CNE2 cells. When we preformed overexpression of Capn4, it reversed the inhibitory effect of miR-124 on the proliferation and invasion of NPC cells. Furthermore, miR-124–Capn4 axis decreased the levels of β-catenin, cyclin D1, and c-Myc, the components of the Wnt/β-catenin signaling pathway.Conclusion: The suppression of proliferation and invasion of NPC cells by miR-124 were achieved by the regulation of Wnt/β-catenin signaling pathway by targeting Capn4. The results of

  13. Ab initio effective core potentials including relativistic effects. II. Potential energy curves for Xe2, Xe+2, and Xe*2

    International Nuclear Information System (INIS)

    Ermler, W.C.; Lee, Y.S.; Pitzer, K.S.; Winter, N.W.

    1978-01-01

    Potential energy curves for the ground 1 Σ + /sub g/ state of Xe 2 , the first four states of the Xe + 2 ions, and the eight Xe* 2 excimer states corresponding to the addition of a 6ssigma/sub g/ Rydberg electron to these ion cores have been computed using averaged relativistic effective core potentials (AREP) and the self-consistent field approximation for the valence electrons. The calculations were carried out using the LS-coupling scheme with the effects of spin--orbit coupling included in the resulting potential energy curves using an empirical procedure. A comparison of nonrelativistic and averaged relativistic EP's and subsequent molecular calculations indicates that relativistic effects arising from the mass--velocity and Darwin terms are not important for these properties of Xe 2 molecules. Spectroscopic constants for Xe + 2 are in good agreement with all electron CI calculations suggesting that the computed values for Xe* 2 excimers should be reliable. The lifetime for the O/sub u/ + state of the Xe 2 * is computed to be 5.6 nsec which is in the range of the experimentally determined values

  14. Hg-Xe exciplex formation in mixed Xe/Ar matrices: molecular dynamics and luminescence study.

    Science.gov (United States)

    Lozada-García, Rolando; Rojas-Lorenzo, Germán; Crépin, Claudine; Ryan, Maryanne; McCaffrey, John G

    2015-03-19

    Luminescence of Hg((3)P1) atoms trapped in mixed Ar/Xe matrices containing a small amount of Xe is reported. Broad emission bands, strongly red-shifted from absorption are recorded which are assigned to strong complexes formed between the excited mercury Hg* and xenon atoms. Molecular dynamics calculations are performed on simulated Xe/Ar samples doped with Hg to follow the behavior of Hg* in the mixed rare gas matrices leading to exciplex formation. The role of Xe atoms in the first solvation shell (SS1) around Hg was investigated in detail, revealing the formation of two kinds of triatomic exciplexes; namely, Xe-Hg*-Xe and Ar-Hg*-Xe. The first species exists only when two xenon atoms are present in SS1 with specific geometries allowing the formation of a linear or quasi-linear exciplex. In the other geometries, or in the presence of only one Xe in SS1, a linear Ar-Hg*-Xe exciplex is formed. The two kinds of exciplexes have different emission bands, the most red-shifted being that involving two Xe atoms, whose emission is very close to that observed in pure Xe matrices. Simulations give a direct access to the analysis of the experimental absorption, emission, and excitation spectra, together with the dynamics of exciplexes formation.

  15. Stark shift measurements of Xe II and Xe III spectral lines

    International Nuclear Information System (INIS)

    Cirisan, M; Pelaez, R J; Djurovic, S; Aparicio, J A; Mar, S

    2007-01-01

    Stark shift measurements of singly and doubly ionized Xe spectral lines are presented in this paper. Shifts of 110 Xe II lines and 42 Xe III lines are reported, including a significant number of new results. A low-pressure-pulsed arc with 95% of He and 5% of Xe was used as a plasma source. All measurements were performed under the following plasma conditions: electron density (0.2-1.4) x 10 23 m -3 and electron temperature 18 000-23 000 K. The measured Stark shifts are compared with other experimental and theoretical data

  16. Hyb-Seq: Combining Target Enrichment and Genome Skimming for Plant Phylogenomics

    Directory of Open Access Journals (Sweden)

    Kevin Weitemier

    2014-08-01

    Full Text Available Premise of the study: Hyb-Seq, the combination of target enrichment and genome skimming, allows simultaneous data collection for low-copy nuclear genes and high-copy genomic targets for plant systematics and evolution studies. Methods and Results: Genome and transcriptome assemblies for milkweed (Asclepias syriaca were used to design enrichment probes for 3385 exons from 768 genes (>1.6 Mbp followed by Illumina sequencing of enriched libraries. Hyb-Seq of 12 individuals (10 Asclepias species and two related genera resulted in at least partial assembly of 92.6% of exons and 99.7% of genes and an average assembly length >2 Mbp. Importantly, complete plastomes and nuclear ribosomal DNA cistrons were assembled using off-target reads. Phylogenomic analyses demonstrated signal conflict between genomes. Conclusions: The Hyb-Seq approach enables targeted sequencing of thousands of low-copy nuclear exons and flanking regions, as well as genome skimming of high-copy repeats and organellar genomes, to efficiently produce genome-scale data sets for phylogenomics.

  17. Excimer lasers utilizing XeF and XeCl molecules

    Energy Technology Data Exchange (ETDEWEB)

    Bychkov, Yu I; Konovalov, I N; Losev, V F; Mesyats, G A; Ryzhov, V V; Tarasenko, V F; Fedorov, A I; Shemyakina, S B; Yastremskii, A G

    1978-12-01

    The results are given of an experimental and theoretical study of XeF (wavelength approx. 350 nm) and XeCl (wavelength approx. 308 nm) lasers excited by an electron beam, a discharge stabilized by an electron beam, and a rapid discharge. These lasers are representative of ones employing halides of noble gases, which are the most powerful sources of stimulated emission in the uv region. The XeCl laser is shown to have good emission characteristics with various methods of excitation. An analysis of the kinetics of processes in the plasma of lasers utilizing halides of noble gases showed that the main channel for the transfer of the beam's energy to the formation of excimer molecules is the ionic channel. An efficiency of about 2.6 percent and a specific radiant energy of 10 J.l/sup -1/ showed that XeCl* is one of the most effective excimer molecules.

  18. Spectra of copperlike and zinclike xenon: Xe XXV and Xe XXVI

    International Nuclear Information System (INIS)

    Kaufman, V.; Sugar, J.; Rowan, W.L.

    1988-01-01

    The spectra of highly ionized xenon were generated in a tokamak plasma and photographed in the region 60--350 A with a 2.2-m grazing-incidence spectrograph. The 4s 2 --4s4p transitions of Zn-like xenon (Xe XXV) and all the 4l--4(l+1) transitions of Cu-like xenon (Xe XXVI) were measured with estimated uncertainties of +- 0.005 A. These measurements have been combined with previous wavelength measurements of Xe XXVI to determine energy levels. A value for the ionization energy of Xe 25+ of 6 912 400 +- 3000 cm -1 (857.0 +- 0.4 eV) was derived

  19. The study of multicomponent separation of Xe isotope by centrifugal method

    International Nuclear Information System (INIS)

    Jinyan Wu; Fu Zhuge

    1996-01-01

    The element Xe has nine isotopes in nature, the separation performance of each component mutually affects the others, so the binary separation theory can't be employed to study the multicomponent separation. Especially, when the molecular wight of a certain component is in the middle of its isotope components, the effect of the others on this component must be considered. In this paper, first, the multicomponent separation of Xe isotopes in a gas centrifuge is studied, with the consideration of the effect of the concentration on the diffusion coefficient and average molecular weight. The multicomponent diffusion equations are solved by the finite difference method. Second, the enrichment of Xe isotopes in a cascade is studied. On the basis of the study of a gas centrifuge, the simplified separation equations of a gas centrifuge for cascade calculation are obtained. Furthermore, the complete equations of the cascade separation are established according to the conservation of mass of each component and solved by a numerical method. The study of this paper can be extended for other isotope separation calculations. (author)

  20. Superficial Velocity Effects on HZ-PAN and AgZ-PAN for Kr/Xe Capture

    Energy Technology Data Exchange (ETDEWEB)

    Welty, Amy Keil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Garn, Troy Gerry [Idaho National Lab. (INL), Idaho Falls, ID (United States); Greenhalgh, Mitchell Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-04-01

    Nearly all previous testing of HZ-PAN and AgZ-PAN was conducted at the same flow rate in order to maintain consistency among tests. This testing was sufficient for sorbent capacity determinations, but did not ensure that sorbents were capable of functioning under a range of flow regimes. Tests were conducted on both HZ-PAN and AgZ-PAN at superficial velocities between 20 and 700 cm/min. For HZ-PAN, Kr capacity increased from 60 mmol/kg to 110 mmol/kg as superficial velocity increased from 21 to 679 cm/min. Results for AgZ-PAN were similar, with capacity ranging from 72 to 124 mmol/kg over the same range of superficial. These results are promising for scaling up to process flows, demonstrating flexibility to operate in a broad range of superficial velocities while maintaining sorbent capacity. While preparing for superficial velocity testing it was also discovered that AgZ-PAN Xe capacity, previously observed to diminish over time, could be recovered with increased desorption temperature. Further, a substantial Xe capacity increase was observed. Previous room temperature capacities in the range of 22-25 mmol Xe/kg AgZ-PAN were increased to over 60 mmol Xe/kg AgZ-PAN. While this finding has not yet been fully explored to optimize activation and desorption temperatures, it is encouraging.

  1. A sensitive zinc-activated 129Xe MRI probe

    International Nuclear Information System (INIS)

    Kotera, N.; Delacour, L.; Traore, T.; Buisson, D.A.; Taran, F.; Coudert, S.; Rousseau, B.; Tassali, N.; Leonce, E.; Boutin, C.; Berthault, P.; Brotin, T.; Dutasta, J.P.

    2012-01-01

    Herein we propose the use of hyper-polarized 129 Xe nuclear magnetic resonance (NMR) spectroscopy for the sensitive detection of Zn 2+ ions. To achieve this goal, the noble gas is encapsulated in dedicated host systems bearing a ligand that chelates the Zn 2+ ions. Cryptophanes, aromatic cage molecules made of cyclotriveratrylene groups, are perfectly suited to this purpose as 1) they can easily be rendered water-soluble, 2) the noble gas has a high affinity for their cavity, 3) when xenon is encapsulated, it takes a specific NMR frequency, and 4) xenon exchange in and out of the cavity insures a continuous refreshment of the Xe-cryptophane environment in hyper-polarization. We constructed a powerful 129 Xe NMR-based sensor of Zn 2+ ions, which enables for the first time measurement of Zn 2+ concentrations as low as 100 nm. This high sensitivity was achieved thanks to a smart 129 Xe MRI sensor, where the binding of the ion to the target is accompanied by a change in NMR parameters. We have also demonstrated the importance of working with enantiopure cryptophane derivatives. (O.M.)

  2. Measurement of Kr-85 and Xe-133 as undisturbed tracers for the representing of atmospheric transport after disposal of radioactivity from nuclear facilities; Messungen von Kr-85 und Xe-133 als ungestoerte Tracer zur Darstellung atmosphaerischer Transportvorgaenge nach Freisetzung von Radioaktivitaet aus kerntechnischen Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    Frank, G.; Steinkopff, T. [Deutscher Wetterdienst (Germany); Salvamoser, J. [Institut fuer Angewandte Isotopen-, Gas- und Umweltuntersuchungen (IGU), Woerthsee (Germany)

    2016-07-01

    The Deutscher Wetterdienst (DWD, German Meteorological Service) operates since 1996 a sampling and measurement device for the radioactive rare gases Kr-85 and Xe-133 in Offenbach. These measurements are embedded in the German Measurement and Information System for Monitoring Environmental Radioactivity (Integriertes Mess- und Informationssystem zur Ueberwachung der Radioaktivitaet in der Umwelt, IMIS) [1]. In addition to these measurements the DWD is sampling rare gases in Potsdam and since 2014 in Trier in cooperation with the Bundesamt fuer Strahlenschutz (Federal Office for Radiation Protection, BfS). In the frame of the Global Atmosphere Watch (GAW)-program of the WMO the DWD operated a sampling station at the Zugspitze (Schneefernerhaus) from 1999 to 2005. This location at the Zugspitze is well suited for the observation of long distance transport of Kr-85 in the higher atmosphere. The DWD in Offenbach operates a complex analytical system for the measurement of Kr-85 and Xe-133 since 1998. This system consists of sampling with first enrichment, second enrichment, gas chromatographic separation and preparation of Krypton and Xenon and measurement of Kr-85 and Xe-133. Using the example Fukushima, it is shown, that the radioactive rare gases Kr-85 and Xe-133 are well undisturbed tracers for atmospheric transport in case of a nuclear accident or routine nuclear reprocessing plants. Measurements of Xe-133, I-131, Cs-137 and Kr-85 are correlated with source and atmospheric transport to the sampling sites at Offenbach and Potsdam.

  3. Hyb-Seq: Combining target enrichment and genome skimming for plant phylogenomics1

    Science.gov (United States)

    Weitemier, Kevin; Straub, Shannon C. K.; Cronn, Richard C.; Fishbein, Mark; Schmickl, Roswitha; McDonnell, Angela; Liston, Aaron

    2014-01-01

    • Premise of the study: Hyb-Seq, the combination of target enrichment and genome skimming, allows simultaneous data collection for low-copy nuclear genes and high-copy genomic targets for plant systematics and evolution studies. • Methods and Results: Genome and transcriptome assemblies for milkweed (Asclepias syriaca) were used to design enrichment probes for 3385 exons from 768 genes (>1.6 Mbp) followed by Illumina sequencing of enriched libraries. Hyb-Seq of 12 individuals (10 Asclepias species and two related genera) resulted in at least partial assembly of 92.6% of exons and 99.7% of genes and an average assembly length >2 Mbp. Importantly, complete plastomes and nuclear ribosomal DNA cistrons were assembled using off-target reads. Phylogenomic analyses demonstrated signal conflict between genomes. • Conclusions: The Hyb-Seq approach enables targeted sequencing of thousands of low-copy nuclear exons and flanking regions, as well as genome skimming of high-copy repeats and organellar genomes, to efficiently produce genome-scale data sets for phylogenomics. PMID:25225629

  4. Multiplex target enrichment using DNA indexing for ultra-high throughput SNP detection.

    LENUS (Irish Health Repository)

    Kenny, Elaine M

    2011-02-01

    Screening large numbers of target regions in multiple DNA samples for sequence variation is an important application of next-generation sequencing but an efficient method to enrich the samples in parallel has yet to be reported. We describe an advanced method that combines DNA samples using indexes or barcodes prior to target enrichment to facilitate this type of experiment. Sequencing libraries for multiple individual DNA samples, each incorporating a unique 6-bp index, are combined in equal quantities, enriched using a single in-solution target enrichment assay and sequenced in a single reaction. Sequence reads are parsed based on the index, allowing sequence analysis of individual samples. We show that the use of indexed samples does not impact on the efficiency of the enrichment reaction. For three- and nine-indexed HapMap DNA samples, the method was found to be highly accurate for SNP identification. Even with sequence coverage as low as 8x, 99% of sequence SNP calls were concordant with known genotypes. Within a single experiment, this method can sequence the exonic regions of hundreds of genes in tens of samples for sequence and structural variation using as little as 1 μg of input DNA per sample.

  5. Energy levels and radiative rates for transitions in B-like to F-like Xe ions (Xe L-XLVI)

    International Nuclear Information System (INIS)

    Aggarwal, K.M.; Keenan, F.P.; Lawson, K.D.

    2010-01-01

    Energy levels, radiative rates, oscillator strengths, line strengths, and lifetimes have been calculated for transitions in B-like to F-like Xe ions, Xe L-XLVI. For the calculations, a fully relativistic GRASP code has been adopted, and results are reported for all electric dipole, electric quadrupole, magnetic dipole, and magnetic quadrupole transitions among the lowest 125, 236, 272, 226, and 113 levels of Xe L, Xe XLIX, Xe XLVIII, Xe XLVII, and Xe XLVI, respectively, belonging to the n ≤ 3 configurations.

  6. The efficacy of high-throughput sequencing and target enrichment on charred archaeobotanical remains

    DEFF Research Database (Denmark)

    Nistelberger, H. M.; Smith, O.; Wales, Nathan

    2016-01-01

    . It has been suggested that high-throughput sequencing (HTS) technologies coupled with DNA enrichment techniques may overcome some of these limitations. Here we report the findings of HTS and target enrichment on four important archaeological crops (barley, grape, maize and rice) performed in three...... lightly-charred maize cob. Even with target enrichment, this sample failed to yield adequate data required to address fundamental questions in archaeology and biology. We further reanalysed part of an existing dataset on charred plant material, and found all purported endogenous DNA sequences were likely...

  7. Investigation of the thermal performance of {sup nat}Te target for {sup 124}I production in the RARS cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Azizakram, Hamid; Zolfagharpour, Farhad [Univ. of Mohaghegh Ardabili, Ardabil (Iran, Islamic Republic of). Dept. of Physics; Sadeghi, Mahdi [Iran Univ. of Medical Science, Tehran (Iran, Islamic Republic of). Medical Physics Dept.; Ashtari, Parviz [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School (RARS); Nikjou, Amir [Payam Noor Univ., Tehran (Iran, Islamic Republic of). Dept. of Physics

    2017-12-15

    Regarding the low thermal conductivity of {sup nat}Te element, the provision of an effective cooling system is one of the critical issues in cyclotron targetry to prevent melting of target matter during the irradiation to {sup 124}I production via {sup nat}Te(p,xn){sup 124}I reaction. Heat transfer on Te target and efficiency of cooling fluid in the solid target system have been simulated based on a Finite Element Analysis (FEA) code for the thermal behavior of the target during the irradiation and under different beam currents, coolant flow rates, substrate matters and target geometry. The results on the routinely used solid target in Radiation Application Research School (RARS) cyclotron showed that in a 3 m/s coolant flow rate, by using a fined-cooling system and a nickel substrate coated on copper backing plate, the irradiation beam current can be raised up to 180 μA without any risk of melting. The cooling flow rates greater than 3 m/s do not noticeably improve the heat dispersion of target layer. As expected, a linear increase was observed for the temperature and temperature gradient of plates in the beam currents of 100-300 μA.

  8. A probability of synthesis of the superheavy element Z = 124

    Energy Technology Data Exchange (ETDEWEB)

    Manjunatha, H.C. [Government College for Women, Department of Physics, Kolar, Karnataka (India); Sridhar, K.N. [Government First Grade College, Department of Physics, Kolar, Karnataka (India)

    2017-10-15

    We have studied the fusion cross section, evaporation residue cross section, compound nucleus formation probability (P{sub CN}) and survival probability (P{sub sur}) of different projectile target combinations to synthesize the superheavy element Z=124. Hence, we have identified the most probable projectile-target combination to synthesize the superheavy element Z = 124. To synthesize the superheavy element Z=124, the most probable projectile target combinations are Kr+Ra, Ni+Cm, Se+Th, Ge+U and Zn+Pu. We hope that our predictions may be a guide for the future experiments in the synthesis of superheavy nuclei Z = 124. (orig.)

  9. Study of solid target preparation for developing I-124, Pd-103, Cu-64 radioisotopes based cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hong; Park, Hyun; Lee, Ji Sub; Lee, Dong Hoon; Chun, Kwon Soo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Choi, Hee Dong [Seoul National Univ., Seoul (Korea, Republic of)

    2005-07-01

    The decay characteristics of I-124, Pd-103 and Cu-64 radioisotopes produced by cyclotron have considered useful agents for diagnostic imaging or therapy. Numbers of radioisotopes used in medical applications or promised for development are produced with solid targets. The aims of developing solid targets are to obtain large quantities of radionuclides from accelerators. The scope of the study is to develop optimized target system and chemical procedures of these radioisotopes. In order to increase the availability of the radionuclides, the investigation for the design of the solid target and different procedures yielding efficient production of high specific activity will be carrying. In this work, we will present the issue of the primary target design concept.

  10. Independent yields of Kr and Xe isotopes in the photofission of heavy nuclei

    International Nuclear Information System (INIS)

    Gangrsky, Yu.P.; Zhemenik, V.I.; Maslova, N.Yu.; Mishinsky, G.V.; Penionzhkevich, Yu.E.; Szoelloes, O.

    2003-01-01

    The yields of Kr (A = 87-93) and Xe (A = 138-143) primary fission fragments produced in 232 Th, 238 U, and 244 Pu photofission upon the scission of a target nucleus and neutron emission were measured in an experiment with bremsstrahlung from electrons accelerated to 25 MeV by a microtron, and the results of these measurements are presented. The experimental procedure used involved the transportation of fragments that escaped from the target by a gas flow through a capillary and the condensation of Kr and Xe inert gases in a cryostat at liquid-nitrogen temperature. The fragments of all other elements were retained with a filter at the capillary inlet. The isotopes of Kr and Xe were identified by the γ spectra of their daughter products. The mass-number distributions of the independent yields of Kr and Xe isotopes are obtained and compared with similar data on fission induced by thermal and fast neutrons; the shifts of the fragment charges with respect to the undistorted charge distribution are determined. Prospects for using photofission fragments in studying the structure of highly neutron-rich nuclei are discussed

  11. 80 A/cm2 electron beams from metal targets irradiated by KrCl and XeCl excimer lasers

    Science.gov (United States)

    Beloglazov, A.; Martino, M.; Nassisi, V.

    1996-05-01

    Due to the growing demand for high-current and long-duration electron-beam devices, laser electron sources were investigated in our laboratory. Experiments on electron-beam generation and propagation from aluminium and copper targets illuminated by XeCl (308 nm) and KrCl (222 nm) excimer lasers, were carried out under plasma ignition due to laser irradiation. This plasma supplied a spontaneous accelerating electric field of about 370 kV/m without an external accelerating voltage. By applying the modified one-dimensional Poisson equation, we computed the expected current and we also estimated the plasma concentration during the accelerating process. At 40 kV of accelerating voltage, an output current pulse of about 80 A/cm2 was detected from an Al target irradiated by the shorter wavelength laser.

  12. Target-dependent enrichment of virions determines the reduction of high-throughput sequencing in virus discovery.

    Directory of Open Access Journals (Sweden)

    Randi Holm Jensen

    Full Text Available Viral infections cause many different diseases stemming both from well-characterized viral pathogens but also from emerging viruses, and the search for novel viruses continues to be of great importance. High-throughput sequencing is an important technology for this purpose. However, viral nucleic acids often constitute a minute proportion of the total genetic material in a sample from infected tissue. Techniques to enrich viral targets in high-throughput sequencing have been reported, but the sensitivity of such methods is not well established. This study compares different library preparation techniques targeting both DNA and RNA with and without virion enrichment. By optimizing the selection of intact virus particles, both by physical and enzymatic approaches, we assessed the effectiveness of the specific enrichment of viral sequences as compared to non-enriched sample preparations by selectively looking for and counting read sequences obtained from shotgun sequencing. Using shotgun sequencing of total DNA or RNA, viral targets were detected at concentrations corresponding to the predicted level, providing a foundation for estimating the effectiveness of virion enrichment. Virion enrichment typically produced a 1000-fold increase in the proportion of DNA virus sequences. For RNA virions the gain was less pronounced with a maximum 13-fold increase. This enrichment varied between the different sample concentrations, with no clear trend. Despite that less sequencing was required to identify target sequences, it was not evident from our data that a lower detection level was achieved by virion enrichment compared to shotgun sequencing.

  13. A Targeted Enrichment Strategy for Massively Parallel Sequencing of Angiosperm Plastid Genomes

    Directory of Open Access Journals (Sweden)

    Gregory W. Stull

    2013-02-01

    Full Text Available Premise of the study: We explored a targeted enrichment strategy to facilitate rapid and low-cost next-generation sequencing (NGS of numerous complete plastid genomes from across the phylogenetic breadth of angiosperms. Methods and Results: A custom RNA probe set including the complete sequences of 22 previously sequenced eudicot plastomes was designed to facilitate hybridization-based targeted enrichment of eudicot plastid genomes. Using this probe set and an Agilent SureSelect targeted enrichment kit, we conducted an enrichment experiment including 24 angiosperms (22 eudicots, two monocots, which were subsequently sequenced on a single lane of the Illumina GAIIx with single-end, 100-bp reads. This approach yielded nearly complete to complete plastid genomes with exceptionally high coverage (mean coverage: 717×, even for the two monocots. Conclusions: Our enrichment experiment was highly successful even though many aspects of the capture process employed were suboptimal. Hence, significant improvements to this methodology are feasible. With this general approach and probe set, it should be possible to sequence more than 300 essentially complete plastid genomes in a single Illumina GAIIx lane (achieving 50× mean coverage. However, given the complications of pooling numerous samples for multiplex sequencing and the limited number of barcodes (e.g., 96 available in commercial kits, we recommend 96 samples as a current practical maximum for multiplex plastome sequencing. This high-throughput approach should facilitate large-scale plastid genome sequencing at any level of phylogenetic diversity in angiosperms.

  14. XeBr exciplex laser

    International Nuclear Information System (INIS)

    Searles, S.K.

    1976-01-01

    Laser emission from the recently discovered XeBr exciplex laser was investigated as a function of the partial pressures of Xe and Br 2 . An optical loss process appears to limit high-pressure operation

  15. Preparation of isotopically enriched mercury sulphide targets

    Energy Technology Data Exchange (ETDEWEB)

    Szerypo, J.; Friebel, H.U.; Frischke, D.; Grossman, R.; Maier, H.J. [Dept. fuer Physik, Univ. Muenchen (LMU) (Germany); Maier-Leibnitz-Lab. (MLL), Garching (Germany)

    2007-07-01

    The primary difficulty in performing nuclear reactions on mercury is to obtain a suitable target. The primary difficulty in performing nuclear reactions on mercury is to obtain a suitable target. The utilization of amalgam targets has been reported in early publications. These targets, however, were lacking homogeneity and in-beam stability. A thorough investigation of literature shows, that HgS, because of its comparatively high chemical and mechanical stability, is one of the more adequate Hg compounds for accelerator target applications. In this presentation we describe the production of HgS targets consisting of an enriched Hg isotope and S of natural isotopic abundance, starting up from HgO. Following the outline given in [3], in this special case HgS can be prepared by dissolving HgO in diluted HNO{sub 3} and subsequent precipitation of the black HgS modification with gaseous H{sub 2}S. Last step of the target production procedure is evaporation-condensation of HgS in vacuum. In the present case, HgS layers of 500 {mu}g/cm{sup 2} on a backing carbon foil of 26 {mu}g/cm{sup 2} with a protective carbon layer of about 20 {mu}g/cm{sup 2} thickness on top of the HgS layer were produced. (orig.)

  16. Measurement of Kr-85 and Xe-133 as undisturbed tracers for the representing of atmospheric transport after disposal of radioactivity from nuclear facilities

    International Nuclear Information System (INIS)

    Frank, G.; Steinkopff, T.; Salvamoser, J.

    2016-01-01

    The Deutscher Wetterdienst (DWD, German Meteorological Service) operates since 1996 a sampling and measurement device for the radioactive rare gases Kr-85 and Xe-133 in Offenbach. These measurements are embedded in the German Measurement and Information System for Monitoring Environmental Radioactivity (Integriertes Mess- und Informationssystem zur Ueberwachung der Radioaktivitaet in der Umwelt, IMIS) [1]. In addition to these measurements the DWD is sampling rare gases in Potsdam and since 2014 in Trier in cooperation with the Bundesamt fuer Strahlenschutz (Federal Office for Radiation Protection, BfS). In the frame of the Global Atmosphere Watch (GAW)-program of the WMO the DWD operated a sampling station at the Zugspitze (Schneefernerhaus) from 1999 to 2005. This location at the Zugspitze is well suited for the observation of long distance transport of Kr-85 in the higher atmosphere. The DWD in Offenbach operates a complex analytical system for the measurement of Kr-85 and Xe-133 since 1998. This system consists of sampling with first enrichment, second enrichment, gas chromatographic separation and preparation of Krypton and Xenon and measurement of Kr-85 and Xe-133. Using the example Fukushima, it is shown, that the radioactive rare gases Kr-85 and Xe-133 are well undisturbed tracers for atmospheric transport in case of a nuclear accident or routine nuclear reprocessing plants. Measurements of Xe-133, I-131, Cs-137 and Kr-85 are correlated with source and atmospheric transport to the sampling sites at Offenbach and Potsdam.

  17. Rb-129Xe spin-exchange rates due to binary and three-body collisions at high Xe pressures

    International Nuclear Information System (INIS)

    Cates, G.D.; Fitzgerald, R.J.; Barton, A.S.; Bogorad, P.; Gatzke, M.; Newbury, N.R.; Saam, B.

    1992-01-01

    We have studied the spin relaxation of 129 Xe nuclei due to collisions with Rb atoms at Xe pressures of 245--1817 Torr. Our results can be characterized by two parameters, the Rb- 129 Xe velocity-averaged binary spin-exchange cross section left-angle σv right-angle and a rate γ M that characterizes spin relaxation due to van der Waals molecules. Our results complement earlier studies performed at Xe pressures of about 1 Torr and N 2 pressures of 10--100 Torr. This work is useful for predicting spin-exchange rates between polarized Rb atoms and 129 Xe nuclei

  18. Combining target enrichment with barcode multiplexing for high throughput SNP discovery

    Directory of Open Access Journals (Sweden)

    Lunke Sebastian

    2010-11-01

    Full Text Available Abstract Background The primary goal of genetic linkage analysis is to identify genes affecting a phenotypic trait. After localisation of the linkage region, efficient genetic dissection of the disease linked loci requires that functional variants are identified across the loci. These functional variations are difficult to detect due to extent of genetic diversity and, to date, incomplete cataloguing of the large number of variants present both within and between populations. Massively parallel sequencing platforms offer unprecedented capacity for variant discovery, however the number of samples analysed are still limited by cost per sample. Some progress has been made in reducing the cost of resequencing using either multiplexing methodologies or through the utilisation of targeted enrichment technologies which provide the ability to resequence genomic areas of interest rather that full genome sequencing. Results We developed a method that combines current multiplexing methodologies with a solution-based target enrichment method to further reduce the cost of resequencing where region-specific sequencing is required. Our multiplex/enrichment strategy produced high quality data with nominal reduction of sequencing depth. We undertook a genotyping study and were successful in the discovery of novel SNP alleles in all samples at uniplex, duplex and pentaplex levels. Conclusion Our work describes the successful combination of a targeted enrichment method and index barcode multiplexing to reduce costs, time and labour associated with processing large sample sets. Furthermore, we have shown that the sequencing depth obtained is adequate for credible SNP genotyping analysis at uniplex, duplex and pentaplex levels.

  19. Enrichment of putative PAX8 target genes at serous epithelial ovarian cancer susceptibility loci

    DEFF Research Database (Denmark)

    Kar, Siddhartha P; Adler, Emily; Tyrer, Jonathan

    2017-01-01

    BACKGROUND: Genome-wide association studies (GWAS) have identified 18 loci associated with serous ovarian cancer (SOC) susceptibility but the biological mechanisms driving these findings remain poorly characterised. Germline cancer risk loci may be enriched for target genes of transcription factors...... (TFs) critical to somatic tumorigenesis. METHODS: All 615 TF-target sets from the Molecular Signatures Database were evaluated using gene set enrichment analysis (GSEA) and three GWAS for SOC risk: discovery (2196 cases/4396 controls), replication (7035 cases/21 693 controls; independent from discovery...... to interact with PAX8 in the literature to the PAX8-target set and applying an alternative to GSEA, interval enrichment, further confirmed this association (P=0.006). Fifteen of the 157 genes from this expanded PAX8 pathway were near eight loci associated with SOC risk at P

  20. Development of dissolution process for metal foil target containing low enriched uranium

    International Nuclear Information System (INIS)

    Srinivasan, B.; Hutter, J.C.; Johnson, G.K.; Vandegrift, G.F.

    1994-01-01

    About six times more low enriched uranium (LEU) metal is needed to produce the same quantity of 99 Mo as from a high enriched uranium (HEU) oxide target, under similar conditions of neutron irradiation. In view of this, the post-irradiation processing procedures of the LEU target are likely to be different from the Cintichem process procedures now in use for the HEU target. The authors have begun a systematic study to develop modified procedures for LEU target dissolution and 99 Mo separation. The dissolution studies include determination of the dissolution rate, chemical state of uranium in the solution, and the heat evolved in the dissolution reaction. From these results the authors conclude that a mixture of nitric and sulfuric acid is a suitable dissolver solution, albeit at higher concentration of nitric acid than in use for the HEU targets. Also, the dissolver vessel now in use for HEU targets is inadequate for the LEU target, since higher temperature and higher pressure will be encountered in the dissolution of LEU targets. The desire is to keep the modifications to the Cintichem process to a minimum, so that the switch from HEU to LEU can be achieved easily

  1. Single electron capture in N^+ -(Ne, Kr, Xe) collisions

    Science.gov (United States)

    Reyes, Pedro G.; Castillo, Fermin; Martinez, Horacio

    2001-05-01

    Total cross sections for single electron capture of N^+ ions impinging on Ne, Kr and Xe were measured in the energy range of 1.5 to 5.0 keV. The electron capture cross sections for all the targets studied are found to be in excellent agreement with previous data in the low-energy range. The present data together with previous measurements give a general shape of the whole curve of single electron capture cross sections for the N^+ - Ne system. For the cases of N^+ - (Kr, Xe) systems, semiempirical calculation using the two-state approximation are in very good agreement with present cross sections data. Research supported by DGAPA IN-100392 and CONACyT 32175-E

  2. Neutron-capture cross-section measurements of Xe136 between 0.4 and 14.8 MeV

    Science.gov (United States)

    Bhike, Megha; Tornow, W.

    2014-03-01

    Fast-neutron-capture cross-section data on Xe136 have been measured with the activation method between 0.4 and 14.8 MeV. The cross section was found to be of the order of 1 mb at the eleven energies investigated. This result is important to interpret potential neutron-induced backgrounds in the enriched xenon observatory and KamLAND-Zen neutrinoless double-β decay searches that use xenon as both source and detector. A high-pressure sphere filled with Xe136 was irradiated with monoenergetic neutrons produced by the reactions 3H(p ,n)3He, 2H(d ,n)3He, and 3H(d ,n)4He. Indium and gold monitor foils were irradiated simultaneously with the Xe136 to determine the incident neutron flux. The activities of the reaction products were measured with high-resolution γ-ray spectroscopy. The present results are compared to predictions from ENDF/B-VII.1 and TENDL-2012.

  3. Dynamic moments of inertia in Xe, Cs and Ba nuclei

    International Nuclear Information System (INIS)

    El-Samman, H.; Barci, V.; Gizon, A.

    1984-01-01

    The γ-rays following the reactions induced by 12 C ions on 115 In, 112 , 117 , 122 Sn and 123 Sb targets have been investigated using six NaI(Tl) detectors in a two-dimensional arrangement. The collective moment of inertia I( 2 ) /sub band/ of 118 , 122 Xe, 123 Cs and 128 , 130 Ba have been extracted from the energy-correlation spectra. The behaviour of these nuclei and the observed differences are interpreted in terms of high-spin collective properties. Data are also presented on the effective moment of inertia I( 2 )/sub eff/ of 118 Xe and 130 Ba measured by sum-spectrometer techniques. 13 references

  4. XENON IN THE PROTOPLANETARY DISK (PPD-Xe)

    Energy Technology Data Exchange (ETDEWEB)

    Marti, K.; Mathew, K. J., E-mail: kattathu.mathew@srs.gov [Department of Chemistry and Biochemistry, University of California, San Diego, La Jolla, CA (United States)

    2015-06-20

    Relationships among solar system Xe components as observed in the solar wind, in planetary atmospheres, and in meteorites are investigated using isotopic correlations. The term PPD-Xe is used for components inferred to have been present in the molecular cloud material that formed the protoplanetary disk (PPD). The evidence of the lack of simple relationships between terrestrial atmospheric Xe and solar or meteoritic components is confirmed. Xe isotopic correlations indicate a heterogeneous PPD composition with variable mixing ratios of the nucleosynthetic component Xe-HL. Solar Xe represents a bulk PPD component, and the isotopic abundances did not change from the time of incorporation into the interior of Mars through times of regolith implantations to the present.

  5. XENON IN THE PROTOPLANETARY DISK (PPD-Xe)

    International Nuclear Information System (INIS)

    Marti, K.; Mathew, K. J.

    2015-01-01

    Relationships among solar system Xe components as observed in the solar wind, in planetary atmospheres, and in meteorites are investigated using isotopic correlations. The term PPD-Xe is used for components inferred to have been present in the molecular cloud material that formed the protoplanetary disk (PPD). The evidence of the lack of simple relationships between terrestrial atmospheric Xe and solar or meteoritic components is confirmed. Xe isotopic correlations indicate a heterogeneous PPD composition with variable mixing ratios of the nucleosynthetic component Xe-HL. Solar Xe represents a bulk PPD component, and the isotopic abundances did not change from the time of incorporation into the interior of Mars through times of regolith implantations to the present

  6. Xenon in the Protoplanetary Disk (PPD-Xe)

    Science.gov (United States)

    Marti, K.; Mathew, K. J.

    2015-06-01

    Relationships among solar system Xe components as observed in the solar wind, in planetary atmospheres, and in meteorites are investigated using isotopic correlations. The term PPD-Xe is used for components inferred to have been present in the molecular cloud material that formed the protoplanetary disk (PPD). The evidence of the lack of simple relationships between terrestrial atmospheric Xe and solar or meteoritic components is confirmed. Xe isotopic correlations indicate a heterogeneous PPD composition with variable mixing ratios of the nucleosynthetic component Xe-HL. Solar Xe represents a bulk PPD component, and the isotopic abundances did not change from the time of incorporation into the interior of Mars through times of regolith implantations to the present.

  7. 133Xe and 135Xe interference with in vivo low-energy measurement systems

    International Nuclear Information System (INIS)

    Cohen, N.; Lo Sasso, T.; Lei, W.

    1980-01-01

    Fission product 133 Xe and 135 Xe are released to the atmosphere during normal reactor operation. With increasing numbers of nuclear power stations there will be an increase in the ambient level of these isotopes. They do not present an appreciable long-term health hazard because of their inert nature and relatively short half-lives. However, their presence in the air of a whole-body counter may interfere significantly with in vivo low-energy photon counting procedures by contributing to the background count-rate in the energy region below 300 keV. This applies particularly to lung and whole-body measurements with dual thin crystal NaI(Tl)-CsI(Tl) scintillation detectors for actinide nuclides. It is important, therefore, that gamma spectroscopists should be aware of the possible presence of 133 Xe and 135 Xe in the air of their whole-body counting facilities, particularly if these are near to reactors and do not have traps for removal of inert gases from their air supplies. (author)

  8. The tumor suppressor role of miR-124 in osteosarcoma.

    Directory of Open Access Journals (Sweden)

    Shuo Geng

    Full Text Available MicroRNAs have crucial roles in development and progression of human cancers, including osteosarcoma. Recent studies have shown that miR-124 was down-regulated in many cancers; however, the role of miR-124 in osteosarcoma development is unknown. In this study, we demonstrate that expression of miR-124 is significantly downregulated in osteosarcoma tissues and cell lines, compared to the adjacent tissues. The expression of miR-124 in the metastases osteosarcoma tissues was lower than that in non- metastases tissues. We identified and confirmed Rac1 as a novel, direct target of miR-124 using prediction algorithms and luciferase reporter gene assays. Overexpression of miR-124 suppressed Rac1 protein expression and attenuated cell proliferation, migration, and invasion and induced apoptosis in MG-63 and U2OS in vitro. Moreover, overexpression of Rac1 in miR-124-transfected osteosarcoma cells effectively rescued the inhibition of cell invasion caused by miR-124. Therefore, our results demonstrate that miR-124 is a tumor suppressor miRNA and suggest that this miRNA could be a potential target for the treatment of osteosarcoma in future.

  9. High energy XeBr electric discharge laser

    Science.gov (United States)

    Sze, Robert C.; Scott, Peter B.

    1981-01-01

    A high energy XeBr laser for producing coherent radiation at 282 nm. The XeBr laser utilizes an electric discharge as the excitation source to minimize formation of molecular ions thereby minimizing absorption of laser radiation by the active medium. Additionally, HBr is used as the halogen donor which undergoes harpooning reactions with Xe.sub.M * to form XeBr*.

  10. Sampling Enrichment toward Target Structures Using Hybrid Molecular Dynamics-Monte Carlo Simulations.

    Directory of Open Access Journals (Sweden)

    Kecheng Yang

    Full Text Available Sampling enrichment toward a target state, an analogue of the improvement of sampling efficiency (SE, is critical in both the refinement of protein structures and the generation of near-native structure ensembles for the exploration of structure-function relationships. We developed a hybrid molecular dynamics (MD-Monte Carlo (MC approach to enrich the sampling toward the target structures. In this approach, the higher SE is achieved by perturbing the conventional MD simulations with a MC structure-acceptance judgment, which is based on the coincidence degree of small angle x-ray scattering (SAXS intensity profiles between the simulation structures and the target structure. We found that the hybrid simulations could significantly improve SE by making the top-ranked models much closer to the target structures both in the secondary and tertiary structures. Specifically, for the 20 mono-residue peptides, when the initial structures had the root-mean-squared deviation (RMSD from the target structure smaller than 7 Å, the hybrid MD-MC simulations afforded, on average, 0.83 Å and 1.73 Å in RMSD closer to the target than the parallel MD simulations at 310K and 370K, respectively. Meanwhile, the average SE values are also increased by 13.2% and 15.7%. The enrichment of sampling becomes more significant when the target states are gradually detectable in the MD-MC simulations in comparison with the parallel MD simulations, and provide >200% improvement in SE. We also performed a test of the hybrid MD-MC approach in the real protein system, the results showed that the SE for 3 out of 5 real proteins are improved. Overall, this work presents an efficient way of utilizing solution SAXS to improve protein structure prediction and refinement, as well as the generation of near native structures for function annotation.

  11. Temperature and energy effects on secondary electron emission from SiC ceramics induced by Xe17+ ions.

    Science.gov (United States)

    Zeng, Lixia; Zhou, Xianming; Cheng, Rui; Wang, Xing; Ren, Jieru; Lei, Yu; Ma, Lidong; Zhao, Yongtao; Zhang, Xiaoan; Xu, Zhongfeng

    2017-07-25

    Secondary electron emission yield from the surface of SiC ceramics induced by Xe 17+ ions has been measured as a function of target temperature and incident energy. In the temperature range of 463-659 K, the total yield gradually decreases with increasing target temperature. The decrease is about 57% for 3.2 MeV Xe 17+ impact, and about 62% for 4.0 MeV Xe 17+ impact, which is much larger than the decrease observed previously for ion impact at low charged states. The yield dependence on the temperature is discussed in terms of work function, because both kinetic electron emission and potential electron emission are influenced by work function. In addition, our experimental data show that the total electron yield gradually increases with the kinetic energy of projectile, when the target is at a constant temperature higher than room temperature. This result can be explained by electronic stopping power which plays an important role in kinetic electron emission.

  12. Actinide production in 136Xe bombardments of 249Cf

    International Nuclear Information System (INIS)

    Gregorich, K.E.

    1985-08-01

    The production cross sections for the actinide products from 136 Xe bombardments of 249 Cf at energies 1.02, 1.09, and 1.16 times the Coulomb barrier were determined. Fractions of the individual actinide elements were chemically separated from recoil catcher foils. The production cross sections of the actinide products were determined by measuring the radiations emitted from the nuclides within the chemical fractions. The chemical separation techniques used in this work are described in detail, and a description of the data analysis procedure is included. The actinide production cross section distributions from these 136 Xe + 249 Cf bombardments are compared with the production cross section distributions from other heavy ion bombardments of actinide targets, with emphasis on the comparison with the 136 Xe + 248 Cm reaction. A technique for modeling the final actinide cross section distributions has been developed and is presented. In this model, the initial (before deexcitation) cross section distribution with respect to the separation energy of a dinuclear complex and with respect to the Z of the target-like fragment is given by an empirical procedure. It is then assumed that the N/Z equilibration in the dinuclear complex occurs by the transfer of neutrons between the two participants in the dinuclear complex. The neutrons and the excitation energy are statistically distributed between the two fragments using a simple Fermi gas level density formalism. The resulting target-like fragment initial cross section distribution with respect to Z, N, and excitation energy is then allowed to deexcite by emission of neutrons in competition with fission. The result is a final cross section distribution with respect to Z and N for the actinide products. 68 refs., 33 figs., 6 tabs

  13. I-124 production using nanomaterials and its biodistribution in animals

    International Nuclear Information System (INIS)

    Braghirolli, Ana Maria Silveira

    2014-01-01

    Iodine-124 is a positron emitter with physical half-life of 4.2 days. Its decay occurs by positron emission (23.3%) and electron capture (76.7%). Their physical and chemical characteristics make it an attractive isotope for medical applications. The development of new imaging techniques, improvements in Positron Emission Tomography (PET), the development of new detectors and computational methods of signal processing, open new perspectives for its application. The increasing use of PET technology in medical oncology, pharmacokinetics and drug metabolism, make the radiopharmaceuticals labeled with 124 I a tool of great interest and usefulness. The use of 124 I - labeled molecules stands out particularly due to the convenient half-life of 124 I. This feature enables diagnostic imaging in PET centers far away from the radionuclides producing center. Within this context, this work presents a method for the production and separation of 124 I. This method is innovative and pioneering in the country. It is based on the development and use of nanostructured targets of nat TeO 2 . These targets are irradiated in a charged particles accelerator, with variable energy, the IEN's CV-28 cyclotron. The irradiations are performed with 24 MeV, initial energy, proton beams. In the preparation of nanoparticulated targets the highlight was the simplicity of the method that uses the sol-gel technique for obtaining nanoparticles, TeCl 4 as precursor and water as solvent. The produced 124 I was separated from the target material by dry distillation and trapped in a NaOH solution (0.02 M), in an automated system. The thick target yield was 6.81 MBq/μAh, and the synthesis yield was 90%. The 124 I obtained was then used in preliminary biodistribution studies. These studies were performed on a micro PET, model Lab PET 4 of the CDTN, in Swiss type mice. The results of the application of Na 124 I showed high quality PET imaging of the thyroid, with the maximum uptake at 6 h after

  14. The Long Non-Coding RNA XIST Interacted with MiR-124 to Modulate Bladder Cancer Growth, Invasion and Migration by Targeting Androgen Receptor (AR).

    Science.gov (United States)

    Xiong, Yaoyao; Wang, Long; Li, Yuan; Chen, Minfeng; He, Wei; Qi, Lin

    2017-01-01

    Long non-coding RNA (lncRNA) X-inactive specific transcript (XIST) is involved in the progression of several tumors. The interaction between lncRNA and miRNA or miRNA's target genes is reported to play crucial roles in malignancy. In addition, Androgen receptor (AR) is considered to be involved in bladder cancer progression. In this study, we investigated the role of XIST in human bladder cancer and its interaction with miR-124 and AR. XIST and AR expression was detected in bladder tumor samples and cell lines. Effects of XIST and AR on bladder cancer cells growth, invasion and migration were analyzed. Bioinformatic analysis and luciferase assays were used to identify the interaction among XIST, AR and miR-124. The correlations of miR-124 with XIST and AR in bladder cancer samples were statistically analyzed. XIST and AR were upregulated in bladder cancer tissues and positively correlated. Higher XIST and AR expression were related to poorer TNM stage of bladder cancer. XIST knockdown reduced bladder cancer cells' proliferation, invasion and migration. While this inhibitory effect could be partially restored by AR overexpression. XIST inhibited miR-124 expression by directly targeting. Moreover, miR-124 could bind to the 3'UTR of AR to regulate its expression. MiR-124 inhibition partially restored the XIST knockdown-induced reduction of AR, c-myc, p27, MMP13 and MMP9 expression. In bladder cancer tissues, miR-124 level was inversely correlated with the expression of XIST and AR, respectively. These findings indicated that XIST might be an oncogenic lncRNA that promoted the bladder cancer growth, invasion and migration via miR-124 dependent AR regulation. © 2017 The Author(s). Published by S. Karger AG, Basel.

  15. The Long Non-Coding RNA XIST Interacted with MiR-124 to Modulate Bladder Cancer Growth, Invasion and Migration by Targeting Androgen Receptor (AR

    Directory of Open Access Journals (Sweden)

    Yaoyao Xiong

    2017-08-01

    Full Text Available Backgrounds/Aims: Long non-coding RNA (lncRNA X-inactive specific transcript (XIST is involved in the progression of several tumors. The interaction between lncRNA and miRNA or miRNA’s target genes is reported to play crucial roles in malignancy. In addition, Androgen receptor (AR is considered to be involved in bladder cancer progression. In this study, we investigated the role of XIST in human bladder cancer and its interaction with miR-124 and AR. Methods: XIST and AR expression was detected in bladder tumor samples and cell lines. Effects of XIST and AR on bladder cancer cells growth, invasion and migration were analyzed. Bioinformatic analysis and luciferase assays were used to identify the interaction among XIST, AR and miR-124. The correlations of miR-124 with XIST and AR in bladder cancer samples were statistically analyzed. Results: XIST and AR were upregulated in bladder cancer tissues and positively correlated. Higher XIST and AR expression were related to poorer TNM stage of bladder cancer. XIST knockdown reduced bladder cancer cells’ proliferation, invasion and migration. While this inhibitory effect could be partially restored by AR overexpression. XIST inhibited miR-124 expression by directly targeting. Moreover, miR-124 could bind to the 3’UTR of AR to regulate its expression. MiR-124 inhibition partially restored the XIST knockdown-induced reduction of AR, c-myc, p27, MMP13 and MMP9 expression. In bladder cancer tissues, miR-124 level was inversely correlated with the expression of XIST and AR, respectively. Conclusion: These findings indicated that XIST might be an oncogenic lncRNA that promoted the bladder cancer growth, invasion and migration via miR-124 dependent AR regulation.

  16. Charge transfer reactions in Xe plasma expansion

    International Nuclear Information System (INIS)

    Jiao, C. Q.; Garscadden, A.; Ganguly, B. N.

    2007-01-01

    Charge transfer reactions of fast Xe ions with hydrocarbons including methane (CH 4 ), ethene (C 2 H 4 ), and propane (C 3 H 8 ) are studied by adding these hydrocarbon gases into a cross flowing Xe plasma expansion. Branching ratios and relative reaction rates for the charge transfers of fast Xe + with each of the three hydrocarbon gases are measured under different rf powers of the inductively coupled Xe discharge. For CH 4 /Xe system, we find that fast Xe + reacts readily with CH 4 generating CH 4 + and CH 3 + in a ratio of 1:0.56, with an estimated rate coefficient of (2.3±0.3)x10 -10 cm 3 /s at 75 W rf power which slowly increases to (2.9±0.3)x10 -10 cm 3 /s at 250 W (error bars reflect only the uncertainties due to the unknown extent of the ion recombination that follows the charge transfer reaction). These observed charge transfer reactions are made possible by the kinetically excited Xe ions produced by free expansion of the plasma. For the C 2 H 4 /Xe system product ions C 2 H 4 + and C 2 H 2 + are observed, and for C 3 H 8 /Xe, C 2 H 4 + and C 2 H 5 + and minor product ions including C 2 H 2 + and C 3 H 7 + are observed

  17. Biological Studies with Laser-Polarized ^129Xe

    Science.gov (United States)

    Tseng, C. H.; Oteiza, E. R.; Wong, G. A.; Walsworth, R. L.; Albert, M. S.; Nascimben, L.; Peled, S.; Sakai, K.; Jolesz, F. A.

    1996-05-01

    We have studied several biological systems using laser-polarized ^129Xe. In certain tissues magnetic resonance imaging (MRI) using inhaled laser-polarized noble gases may provide images superior to those from conventional proton MRI. High resolution laser-polarized ^3He images of air spaces in the human lung were recently obtained by the Princeton/Duke group. However, ^3He is not very soluble in tissue. Therefore, we are using laser polarized ^129Xe (tissue-soluble), with the long term goal of biomedical functional imaging. We have investigated multi-echo and multi-excitation magnetic resonance detection schemes to exploit the highly non-thermal ^129Xe magnetization produced by the laser polarization technique. We have inhalated live rats with laser-polarized ^129Xe gas and measured three distinct ^129Xe tissue resonances that last 20 to 40 sec. As a demonstration, we obtained a laser polarized ^129Xe image of the human oral cavity. Currently we are measuring the polarization lifetime of ^129Xe dissolved in human blood, the biological transporting medium. These studies and other recent developments will be reported.

  18. Emission characteristics of Xe-RbBr plasma

    Science.gov (United States)

    Heneral, A. A.; Avtaeva, S. V.

    2017-12-01

    The luminescence spectra of the longitudinal pulsed-periodic discharge in Xe-RbBr gas-vapour mixtures at low pressures are experimentally studied. Conditions for obtaining strong UV radiation of XeBr* exiplex molecules in the spectral range of 200-425 nm are found. The greatest output of the XeBr* UV radiation is provided at temperature of the gas-discharge tube walls of ~1000 K. The maximum UV emission power of the whole plasma volume is 4.8 W. Formation of XeBr* exciplex molecules in the pulsed-periodic discharge in Xe-RbBr gas-vapour mixtures at low pressures is discussed.

  19. Synthesis of new host molecules and applications for imaging by NMR Xe

    International Nuclear Information System (INIS)

    Traore, T.

    2011-01-01

    Magnetic Resonance Imaging (MRI) is widely used today for early medical diagnosis. During the MRI examination, the use of contrast agent allows the obtention of well resolved images. However the lack of sensibility of this technic lead to the utilization of hyper-polarized species ( 3 He, 13 C, 129 Xe) in MRI. The xenon (Xe) is the more promising but due to its weak selectivity, it cannot be used in molecular imaging. So, the development and utilization of host molecules able to encapsulate the xenon and bring it to a targeted biological tissue or organ is necessary. In these conditions, during this thesis, we worked on the elaboration of such molecules, and particularly, in cryptophanes since these compounds have strong affinity for xenon and could be used as tools for MRI by hyper-polarized xenon (Hp Xe). A new route synthesis of cryptophane-111, that has the highest affinity for xenon, was developed; first functionalized derivatives of this compound have been also obtained in order to obtain the first biosensors based on cryptophane-111. The coating of specific ligand on these functionalized compounds could allow targeted MRI. A probe for hydrogen peroxide (H 2 O 2 ) detection was synthesized. Hydrogen peroxide is implicated in cellular oxidative stress and present in case of neuro-degenerative diseases (Parkinson, Alzheimer). The probe obtained allowed the imaging of H 2 O 2 by MRI Xe for the first time. nano-tubes functionalized with strong concentration of cryptophane have been synthesized in order to increase the sensitivity of the imaging technic that uses xenon. (author) [fr

  20. Converting targets and processes for fission-product molybdenum-99 from high- to low-enriched uranium

    International Nuclear Information System (INIS)

    Vandegrift, G.F.; Snelgrove, J.L.; Aase, S.

    1999-01-01

    Most of the world's supply of 99 Mo is produced by the fissioning of 235 U in high-enriched uranium targets (HEU, generally 93% 235 U). To reduce nuclear-proliferation concerns, the U.S. Reduced Enrichment for Research and Test Reactor Program is working to convert the current HEU targets to low-enriched uranium (LEU, 235 U). Switching to LEU targets also requires modifying the separation processes. Current HEU processes can be classified into two main groups based on whether the irradiated target is dissolved in acid or base. Our program has been working on both fronts, with development of targets for acid-side processes being the furthest along. However, using an LEU metal foil target may allow the facile replacement of HEU for both acid and basic dissolution processes. Demonstration of the irradiation and 99 Mo separation processes for the LEU metal-foil targets is being done in cooperation with researchers at the Indonesian PUSPIPTEK facility. We are also developing LEU UO 2 /Al dispersion plates as substitutes for HEU UA1 x /A1 dispersion plates for base-side processes. Results show that conversion to LEU is technically feasible; working with producers is essential to lowering any economic penalty associated with conversion. (author)

  1. Syntheses, Raman spectra, and X-ray crystal structures of [XeF(5)][mu-F(OsO(3)F(2))(2)] and [M][OsO(3)F(3)] (M = XeF(5)(+), Xe(2)F(11)(+)).

    Science.gov (United States)

    Hughes, Michael J; Mercier, Hélène P A; Schrobilgen, Gary J

    2010-04-05

    Stoichiometric amounts of XeF(6) and (OsO(3)F(2))(infinity) react at 25-50 degrees C to form salts of the known XeF(5)(+) and Xe(2)F(11)(+) cations, namely, [XeF(5)][mu-F(OsO(3)F(2))(2)], [XeF(5)][OsO(3)F(3)], and [Xe(2)F(11)][OsO(3)F(3)]. Although XeF(6) is oxophilic toward a number of transition metal and main-group oxides and oxide fluorides, fluoride/oxide metathesis was not observed. The series provides the first examples of noble-gas cations that are stabilized by metal oxide fluoride anions and the first example of a mu-F(OsO(3)F(2))(2)(-) salt. Both [XeF(5)][mu-F(OsO(3)F(2))(2)] and [Xe(2)F(11)][OsO(3)F(3)] are orange solids at room temperature. The [XeF(5)][OsO(3)F(3)] salt is an orange liquid at room temperature that solidifies at 5-0 degrees C. When the salts are heated at 50 degrees C under 1 atm of N(2) for more than 2 h, significant XeF(6) loss occurs. The X-ray crystal structures (-173 degrees C) show that the salts exist as discrete ion pairs and that the osmium coordination spheres in OsO(3)F(3)(-) and mu-F(OsO(3)F(2))(2)(-) are pseudo-octahedral OsO(3)F(3)-units having facial arrangements of oxygen and fluorine atoms. The mu-F(OsO(3)F(2))(2)(-) anion is comprised of two symmetry-related OsO(3)F(2)-groups that are fluorine-bridged to one another. Ion pairing results from secondary bonding interactions between the fluorine/oxygen atoms of the anions and the xenon atom of the cation, with the Xe...F/O contacts occurring opposite the axial fluorine and from beneath the equatorial XeF(4)-planes of the XeF(5)(+) and Xe(2)F(11)(+) cations so as to avoid the free valence electron lone pairs of the xenon atoms. The xenon atoms of [XeF(5)][mu-F(OsO(3)F(2))(2)] and [Xe(2)F(11)][OsO(3)F(3)] are nine-coordinate and the xenon atom of [XeF(5)][OsO(3)F(3)] is eight-coordinate. Quantum-chemical calculations at SVWN and B3LYP levels of theory were used to obtain the gas-phase geometries, vibrational frequencies, and NBO bond orders, valencies, and NPA charges of

  2. Independent yields of Kr and Xe isotopes for the photofission of heavy nuclei

    CERN Document Server

    Gangrskij, Y P; Mishinskij, G V; Penionzhkevich, Yu E; Szoelloes, O; Zhemenik, V I

    2002-01-01

    Presented are the yields of primary fission fragments (produced in the process of the rupture of the nucleus) of Kr (A = 87- 93) and Xe (A 148-143) for the photofission of sup 2 sup 3 sup 2 Th, sup 2 sup 3 sup 8 U and sup 2 sup 4 sup 4 Pu, which were measured using Bremsstrahlung from a microtron, the energy of accelerated electrons being 25 MeV. A technique was used that includes transportation of fragments escaped from the target with a gas flow through a capillary and the condensation of Kr and Xe inert gases in a cryostat at the temperature of liquid nitrogen. Fragments of all the other elements were retained with a filter at the entrance of the capillary. Kr and Xe isotopes were identified by the gamma spectra of their daughter products. The mass number distributions are obtained of the independent yields of Kr and Xe isotopes, which are compared with the similar characteristics for the fission induced by thermal and fast neutrons; the charge shifts for the fragments under study relative to the unchanged...

  3. Independent Yields of Kr and Xe Isotopes for the Photofission of Heavy Nuclei

    CERN Document Server

    Gangrsky, Yu P; Maslova, N Yu; Penionzhkevich, Yu E; Szöllös, O; Zhemenik, V I

    2002-01-01

    Presented are the yields of primary fission fragments (produced in the process of the rupture of the nucleus) of Kr (A=87-93) and Xe (A=148-143) for the photofission of ^{232}Th, ^{238}U and ^{244}Pu, which were measured using bremsstrahlung from a microtron, the energy of accelerated electrons being 25 MeV. A technique was used that includes transportation of fragments escaped from the target with a gas flow through a capillary and the condensation of Kr and Xe inert gases in a cryostat at the temperature of liquid nitrogen. Fragments of all the other elements were retained with a filter at the entrance of capillary. Kr and Xe isotopes were identified by the gamma-spectra of their daughter products. The mass number distributions are obtained of the independent yields of Kr and Xe isotopes, which are compared with the similar characteristics for the fission induced by thermal and fast neutrons; the charge shifts for the fragments under study relative to the unchanged charge distribution are determined. The pe...

  4. Cyclotron production of {sup 61}Cu using natural Zn and enriched {sup 64}Zn targets

    Energy Technology Data Exchange (ETDEWEB)

    Asad, A. H.; Smith, S. V.; Chan, S.; Jeffery, C. M.; Morandeau, L.; Price, R. I. [RAPID PET Labs, Medical Technology and Physics, Sir Charles Gairdner Hospital, Perth, Australia, Imaging and Applied Physics, Curtin University, Perth, Australia, and Center of Excellence in Anti-matter Matter Studies, Australian National University, Can (Australia); Brookhaven National Laboratory, Upton, NY (United States) and Center of Excellence in Anti-matter Matter Studies, Australian National University, Canberra (Australia); RAPID PET Labs, Medical Technology and Physics, Sir Charles Gairdner Hospital, Perth (Australia); RAPID PET Labs, Medical Technology and Physics, Sir Charles Gairdner Hospital, Perth (Australia); Center of Excellence in Anti-matter Matter Studies, Australian National University, Canberra, Australia, and Chemistry, University of Western Australia, Pe (Australia); RAPID PET Labs, Medical Technology and Physics, Sir Charles Gairdner Hospital, Perth (Australia); RAPID PET Labs, Medical Technology and Physics, Sir Charles Gairdner Hospital, Perth, Australia and Physics, University of Western Australia, Perth (Australia)

    2012-12-19

    Copper-61 ({sup 61}Cu) shares with {sup 64}Cu certain advantages for PET diagnostic imaging, but has a shorter half-life (3.4hr vs. 12.7hr) and a greater probability of positron production per disintegration (61% vs. 17.9%). One important application is for in vivo imaging of hypoxic tissue. In this study {sup 61}Cu was produced using the {sup 64}Zn(p,{alpha}){sup 61}Cu reaction on natural Zn or enriched {sup 64}Zn targets. The enriched {sup 64}Zn (99.82%) was electroplated onto high purity gold or silver foils or onto thin Al discs. A typical target bombardment used 30{mu}A; at 11.7, 14.5 or 17.6MeV over 30-60min. The {sup 61}Cu (radiochemical purity of >95%) was separated using a combination of cation and anion exchange columns. The {sup 64}Zn target material was recovered after each run, for re-use. In a direct comparison with enriched {sup 64}Zn-target results, {sup 61}Cu production using the cheaper {sup nat}Zn target proved to be an effective alternative.

  5. Charged particle suppression in Pb+Pb and Xe+Xe collisions measured with the ATLAS detector

    CERN Document Server

    Balek, Petr; The ATLAS collaboration

    2018-01-01

    The measurement of charge particle production in heavy ion collisions, when compared with pp data, provides insight into the properties of the hot and dense quark-gluon plasma. The ATLAS detector at the LHC recorded 0.49 nb$^{−1}$ of Pb+Pb collisions and 4.2 pb$^{−1}$ of pp collisions, both at the center-of-mass energy $\\sqrt{s}=\\sqrt{s_{NN}}=5.02$ TeV. Recently, ATLAS also recorded 3 $\\mu$b$^{−1}$ of Xe+Xe collisions at $\\sqrt{s_{NN}}=5.44$ TeV, which offers a new opportunity to study the system size dependence of the parton energy loss. The large acceptance of the ATLAS detector allows measurements of charged hadron spectra in a wide range of both pseudorapidity and transverse momentum, differentially in collision centrality. The charged hadron spectra measured in Pb+Pb and Xe+Xe collisions are compared to the analogous spectra measured in pp collisions, and the resulting nuclear modification factors $R_{AA}$ are studied.

  6. Observation of K- and L-REC in 200 MeV/u Xe54+-N2 collisions at HIRFL-CSR

    International Nuclear Information System (INIS)

    Yu Deyang; Xue Yingli; Shao Caojie; Song Zhangyong; Lu Rongchun; Ruan Fangfang; Wang Wei; Chen Jing; Yang Bian; Yang Zhihu; Wan Jianjie; Dong Chenzhong; Cai Xiaohong

    2011-01-01

    The 200 MeV/u Xe 54+ ions were utilized to collide with N 2 molecules and the K- and L-REC, as well as the Lyman lines of Xe 53+ were observed. After electron cooling, the ion beam momentum spread ΔP/P ∼ 2.2 x 10 -5 was achieved and the target thickness was stabilized at about 10 13 atom/cm 2 . As the first atomic experiment at HIRFL-CSR with the internal target, its feasibility and stability were verified.

  7. Enrichment of target sequences for next-generation sequencing applications in research and diagnostics.

    Science.gov (United States)

    Altmüller, Janine; Budde, Birgit S; Nürnberg, Peter

    2014-02-01

    Abstract Targeted re-sequencing such as gene panel sequencing (GPS) has become very popular in medical genetics, both for research projects and in diagnostic settings. The technical principles of the different enrichment methods have been reviewed several times before; however, new enrichment products are constantly entering the market, and researchers are often puzzled about the requirement to take decisions about long-term commitments, both for the enrichment product and the sequencing technology. This review summarizes important considerations for the experimental design and provides helpful recommendations in choosing the best sequencing strategy for various research projects and diagnostic applications.

  8. Progress on the IPNS Enriched Uranium Booster Target

    International Nuclear Information System (INIS)

    Knox, A.E.; Carpenter, J.M.; Bailey, J.L.

    1986-09-01

    We describe the Enriched Uranium Booster Target designed for use in Argonne's Intense Pulsed Neutron Source. This report contains a general description of the system, and descriptions of the thermal-hydraulic and loss-of-coolant accident analyses, of the neutronic, criticality and power density calculations, of the assessment of radiation and thermal cycling growth, and of the disk fabrication methods. We also describe the calculations of radionuclide buildup and the related hazards analysis and our calculations of the temperature and stress profiles in the disks, and briefly allude to considerations of security and safeguards

  9. Total and elastic electron scattering cross sections from Xe at intermediate and high energies

    International Nuclear Information System (INIS)

    Garcia, G; Pablos, J L de; Blanco, F; Williart, A

    2002-01-01

    Experimental total electron scattering cross sections from Xe in the energy range 300-5000 eV have been obtained with experimental errors of about 3%. The method was based on the measurement of the attenuation of a linear electron beam through a Xe gas cell in combination with an electron spectroscopy technique to analyse the energy of the transmitted electrons. Differential and integral elastic cross sections have been calculated using a scattering potential method which includes relativistic effects. The consistency of our theoretical and experimental results is also discussed in the paper. Finally, analytical formulae depending on two parameters, namely the number of target electrons and the atomic polarizability, are given to reproduce the experimental data for Ne, Ar, Kr and Xe in the energy range 500-10 000 eV

  10. MicroRNA-124 inhibits the progression of adjuvant-induced arthritis in rats.

    Science.gov (United States)

    Nakamachi, Yuji; Ohnuma, Kenichiro; Uto, Kenichi; Noguchi, Yoriko; Saegusa, Jun; Kawano, Seiji

    2016-03-01

    MicroRNAs (miRNAs) are small endogenous, non-coding RNAs that act as post-transcriptional regulators. We analysed the in vivo effect of miRNA-124 (miR-124, the rat analogue of human miR-124a) on adjuvant-induced arthritis (AIA) in rats. AIA was induced in Lewis rats by injecting incomplete Freund's adjuvant with heat-killed Mycobacterium tuberculosis. Precursor (pre)-miR-124 was injected into the right hind ankle on day 9. Morphological changes in the ankle joint were assessed by micro-CT and histopathology. Cytokine expression was examined by western blotting and real-time RT-PCR. The effect of miR-124 on predicted target messenger RNAs (mRNAs) was examined by luciferase reporter assays. The effect of pre-miR-124 or pre-miR-124a on the differentiation of human osteoclasts was examined by tartrate-resistant acid phosphatase staining. We found that miR-124 suppressed AIA in rats, as demonstrated by decreased synoviocyte proliferation, leucocyte infiltration and cartilage or bone destruction. Osteoclast counts and expression level of receptor activator of the nuclear factor κB ligand (RANKL), integrin β1 (ITGB1) and nuclear factor of activated T cells cytoplasmic 1 (NFATc1) were reduced in AIA rats treated with pre-miR-124. Luciferase analysis showed that miR-124 directly targeted the 3'UTR of the rat NFATc1, ITGB1, specificity protein 1 and CCAAT/enhancer-binding protein α mRNAs. Pre-miR-124 also suppressed NFATc1 expression in RAW264.7 cells. Both miR-124 and miR-124a directly targeted the 3'-UTR of human NFATc1 mRNA, and both pre-miR-124 and pre-miR-124a suppressed the differentiation of human osteoclasts. We found that miR-124 ameliorated AIA by suppressing critical prerequisites for arthritis development, such as RANKL and NFATc1. Thus, miR-124a is a candidate for therapeutic use for human rheumatoid arthritis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. Inclusive J/$\\psi$ production in Xe-Xe collisions at $\\sqrt{s_{NN}}$ = 5.44 TeV

    CERN Document Server

    Acharya, Shreyasi; The ALICE collaboration; Adamova, Dagmar; Adolfsson, Jonatan; Aggarwal, Madan Mohan; Aglieri Rinella, Gianluca; Agnello, Michelangelo; Agrawal, Neelima; Ahammed, Zubayer; Ahn, Sang Un; Aiola, Salvatore; Akindinov, Alexander; Al-turany, Mohammad; Alam, Sk Noor; Silva De Albuquerque, Danilo; Aleksandrov, Dmitry; Alessandro, Bruno; Alfaro Molina, Jose Ruben; Ali, Yasir; Alici, Andrea; Alkin, Anton; Alme, Johan; Alt, Torsten; Altenkamper, Lucas; Altsybeev, Igor; Anaam, Mustafa Naji; Andrei, Cristian; Andreou, Dimitra; Andrews, Harry Arthur; Andronic, Anton; Angeletti, Massimo; Anguelov, Venelin; Anson, Christopher Daniel; Anticic, Tome; Antinori, Federico; Antonioli, Pietro; Anwar, Rafay; Apadula, Nicole; Aphecetche, Laurent Bernard; Appelshaeuser, Harald; Arcelli, Silvia; Arnaldi, Roberta; Arnold, Oliver Werner; Arsene, Ionut Cristian; Arslandok, Mesut; Audurier, Benjamin; Augustinus, Andre; Averbeck, Ralf Peter; Azmi, Mohd Danish; Badala, Angela; Baek, Yong Wook; Bagnasco, Stefano; Bailhache, Raphaelle Marie; Bala, Renu; Baldisseri, Alberto; Ball, Markus; Baral, Rama Chandra; Barbano, Anastasia Maria; Barbera, Roberto; Barile, Francesco; Barioglio, Luca; Barnafoldi, Gergely Gabor; Barnby, Lee Stuart; Ramillien Barret, Valerie; Bartalini, Paolo; Barth, Klaus; Bartsch, Esther; Bastid, Nicole; Basu, Sumit; Batigne, Guillaume; Batyunya, Boris; Batzing, Paul Christoph; Bazo Alba, Jose Luis; Bearden, Ian Gardner; Beck, Hans; Bedda, Cristina; Behera, Nirbhay Kumar; Belikov, Iouri; Bellini, Francesca; Bello Martinez, Hector; Bellwied, Rene; Espinoza Beltran, Lucina Gabriela; Belyaev, Vladimir; Bencedi, Gyula; Beole, Stefania; Bercuci, Alexandru; Berdnikov, Yaroslav; Berenyi, Daniel; Bertens, Redmer Alexander; Berzano, Dario; Betev, Latchezar; Bhaduri, Partha Pratim; Bhasin, Anju; Bhat, Inayat Rasool; Bhatt, Himani; Bhattacharjee, Buddhadeb; Bhom, Jihyun; Bianchi, Antonio; Bianchi, Livio; Bianchi, Nicola; Bielcik, Jaroslav; Bielcikova, Jana; Bilandzic, Ante; Biro, Gabor; Biswas, Rathijit; Biswas, Saikat; Blair, Justin Thomas; Blau, Dmitry; Blume, Christoph; Boca, Gianluigi; Bock, Friederike; Bogdanov, Alexey; Boldizsar, Laszlo; Bombara, Marek; Bonomi, Germano; Bonora, Matthias; Borel, Herve; Borissov, Alexander; Borri, Marcello; Botta, Elena; Bourjau, Christian; Bratrud, Lars; Braun-munzinger, Peter; Bregant, Marco; Broker, Theo Alexander; Broz, Michal; Brucken, Erik Jens; Bruna, Elena; Bruno, Giuseppe Eugenio; Budnikov, Dmitry; Buesching, Henner; Bufalino, Stefania; Buhler, Paul; Buncic, Predrag; Busch, Oliver; Buthelezi, Edith Zinhle; Bashir Butt, Jamila; Buxton, Jesse Thomas; Cabala, Jan; Caffarri, Davide; Caines, Helen Louise; Caliva, Alberto; Calvo Villar, Ernesto; Soto Camacho, Rabi; Camerini, Paolo; Capon, Aaron Allan; Carena, Francesco; Carena, Wisla; Carnesecchi, Francesca; Castillo Castellanos, Javier Ernesto; Castro, Andrew John; Casula, Ester Anna Rita; Ceballos Sanchez, Cesar; Chandra, Sinjini; Chang, Beomsu; Chang, Wan; Chapeland, Sylvain; Chartier, Marielle; Chattopadhyay, Subhasis; Chattopadhyay, Sukalyan; Chauvin, Alex; Cheshkov, Cvetan Valeriev; Cheynis, Brigitte; Chibante Barroso, Vasco Miguel; Dobrigkeit Chinellato, David; Cho, Soyeon; Chochula, Peter; Chowdhury, Tasnuva; Christakoglou, Panagiotis; Christensen, Christian Holm; Christiansen, Peter; Chujo, Tatsuya; Chung, Suh-urk; Cicalo, Corrado; Cifarelli, Luisa; Cindolo, Federico; Cleymans, Jean Willy Andre; Colamaria, Fabio Filippo; Colella, Domenico; Collu, Alberto; Colocci, Manuel; Concas, Matteo; Conesa Balbastre, Gustavo; Conesa Del Valle, Zaida; Contreras Nuno, Jesus Guillermo; Cormier, Thomas Michael; Corrales Morales, Yasser; Cortese, Pietro; Cosentino, Mauro Rogerio; Costa, Filippo; Costanza, Susanna; Crkovska, Jana; Crochet, Philippe; Cuautle Flores, Eleazar; Cunqueiro Mendez, Leticia; Dahms, Torsten; Dainese, Andrea; Dani, Sanskruti; Danisch, Meike Charlotte; Danu, Andrea; Das, Debasish; Das, Indranil; Das, Supriya; Dash, Ajay Kumar; Dash, Sadhana; De, Sudipan; De Caro, Annalisa; De Cataldo, Giacinto; De Conti, Camila; De Cuveland, Jan; De Falco, Alessandro; De Gruttola, Daniele; De Marco, Nora; De Pasquale, Salvatore; Derradi De Souza, Rafael; Franz Degenhardt, Hermann; Deisting, Alexander; Deloff, Andrzej; Delsanto, Silvia; Deplano, Caterina; Dhankher, Preeti; Di Bari, Domenico; Di Mauro, Antonio; Di Ruzza, Benedetto; Arteche Diaz, Raul; Dietel, Thomas; Dillenseger, Pascal; Ding, Yanchun; Divia, Roberto; Djuvsland, Oeystein; Dobrin, Alexandru Florin; Domenicis Gimenez, Diogenes; Donigus, Benjamin; Dordic, Olja; Van Doremalen, Lennart Vincent; Dubey, Anand Kumar; Dubla, Andrea; Ducroux, Laurent; Dudi, Sandeep; Duggal, Ashpreet Kaur; Dukhishyam, Mallick; Dupieux, Pascal; Ehlers Iii, Raymond James; Elia, Domenico; Endress, Eric; Engel, Heiko; Epple, Eliane; Erazmus, Barbara Ewa; Erhardt, Filip; Ersdal, Magnus Rentsch; Espagnon, Bruno; Eulisse, Giulio; Eum, Jongsik; Evans, David; Evdokimov, Sergey; Fabbietti, Laura; Faggin, Mattia; Faivre, Julien; Fantoni, Alessandra; Fasel, Markus; Feldkamp, Linus; Feliciello, Alessandro; Feofilov, Grigorii; Fernandez Tellez, Arturo; Ferretti, Alessandro; Festanti, Andrea; Feuillard, Victor Jose Gaston; Figiel, Jan; Araujo Silva Figueredo, Marcel; Filchagin, Sergey; Finogeev, Dmitry; Fionda, Fiorella; Fiorenza, Gabriele; Flor, Fernando; Floris, Michele; Foertsch, Siegfried Valentin; Foka, Panagiota; Fokin, Sergey; Fragiacomo, Enrico; Francescon, Andrea; Francisco, Audrey; Frankenfeld, Ulrich Michael; Fronze, Gabriele Gaetano; Fuchs, Ulrich; Furget, Christophe; Furs, Artur; Fusco Girard, Mario; Gaardhoeje, Jens Joergen; Gagliardi, Martino; Gago Medina, Alberto Martin; Gajdosova, Katarina; Gallio, Mauro; Duarte Galvan, Carlos; Ganoti, Paraskevi; Garabatos Cuadrado, Jose; Garcia-solis, Edmundo Javier; Garg, Kunal; Gargiulo, Corrado; Gasik, Piotr Jan; Gauger, Erin Frances; De Leone Gay, Maria Beatriz; Germain, Marie; Ghosh, Jhuma; Ghosh, Premomoy; Ghosh, Sanjay Kumar; Gianotti, Paola; Giubellino, Paolo; Giubilato, Piero; Glassel, Peter; Gomez Coral, Diego Mauricio; Gomez Ramirez, Andres; Gonzalez, Victor; Gonzalez Zamora, Pedro; Gorbunov, Sergey; Gorlich, Lidia Maria; Gotovac, Sven; Grabski, Varlen; Graczykowski, Lukasz Kamil; Graham, Katie Leanne; Greiner, Leo Clifford; Grelli, Alessandro; Grigoras, Costin; Grigoryev, Vladislav; Grigoryan, Ara; Grigoryan, Smbat; Gronefeld, Julius Maximilian; Grosa, Fabrizio; Grosse-oetringhaus, Jan Fiete; Grosso, Raffaele; Guernane, Rachid; Guerzoni, Barbara; Guittiere, Manuel; Gulbrandsen, Kristjan Herlache; Gunji, Taku; Gupta, Anik; Gupta, Ramni; Bautista Guzman, Irais; Haake, Rudiger; Habib, Michael Karim; Hadjidakis, Cynthia Marie; Hamagaki, Hideki; Hamar, Gergoe; Hamid, Mohammed; Hamon, Julien Charles; Hannigan, Ryan; Haque, Md Rihan; Harris, John William; Harton, Austin Vincent; Hassan, Hadi; Hatzifotiadou, Despina; Hayashi, Shinichi; Heckel, Stefan Thomas; Hellbar, Ernst; Helstrup, Haavard; Herghelegiu, Andrei Ionut; Gonzalez Hernandez, Emma; Herrera Corral, Gerardo Antonio; Herrmann, Florian; Hetland, Kristin Fanebust; Hilden, Timo Eero; Hillemanns, Hartmut; Hills, Christopher; Hippolyte, Boris; Hohlweger, Bernhard; Horak, David; Hornung, Sebastian; Hosokawa, Ritsuya; Hota, Jyotishree; Hristov, Peter Zahariev; Huang, Chun-lu; Hughes, Charles; Huhn, Patrick; Humanic, Thomas; Hushnud, Hushnud; Hussain, Nur; Hussain, Tahir; Hutter, Dirk; Hwang, Dae Sung; Iddon, James Philip; Iga Buitron, Sergio Arturo; Ilkaev, Radiy; Inaba, Motoi; Ippolitov, Mikhail; Islam, Md Samsul; Ivanov, Marian; Ivanov, Vladimir; Izucheev, Vladimir; Jacak, Barbara; Jacazio, Nicolo; Jacobs, Peter Martin; Jadhav, Manoj Bhanudas; Jadlovska, Slavka; Jadlovsky, Jan; Jaelani, Syaefudin; Jahnke, Cristiane; Jakubowska, Monika Joanna; Janik, Malgorzata Anna; Jena, Chitrasen; Jercic, Marko; Jevons, Oliver; Jimenez Bustamante, Raul Tonatiuh; Jin, Muqing; Jones, Peter Graham; Jusko, Anton; Kalinak, Peter; Kalweit, Alexander Philipp; Kang, Ju Hwan; Kaplin, Vladimir; Kar, Somnath; Karasu Uysal, Ayben; Karavichev, Oleg; Karavicheva, Tatiana; Karczmarczyk, Przemyslaw; Karpechev, Evgeny; Kebschull, Udo Wolfgang; Keidel, Ralf; Keijdener, Darius Laurens; Keil, Markus; Ketzer, Bernhard Franz; Khabanova, Zhanna; Khan, Ahsan Mehmood; Khan, Shaista; Khan, Shuaib Ahmad; Khanzadeev, Alexei; Kharlov, Yury; Khatun, Anisa; Khuntia, Arvind; Kielbowicz, Miroslaw Marek; Kileng, Bjarte; Kim, Byungchul; Kim, Daehyeok; Kim, Dong Jo; Kim, Eun Joo; Kim, Hyeonjoong; Kim, Jinsook; Kim, Jiyoung; Kim, Minjung; Kim, Se Yong; Kim, Taejun; Kim, Taesoo; Kirsch, Stefan; Kisel, Ivan; Kiselev, Sergey; Kisiel, Adam Ryszard; Klay, Jennifer Lynn; Klein, Carsten; Klein, Jochen; Klein-boesing, Christian; Klewin, Sebastian; Kluge, Alexander; Knichel, Michael Linus; Knospe, Anders Garritt; Kobdaj, Chinorat; Varga-kofarago, Monika; Kohler, Markus Konrad; Kollegger, Thorsten; Kondratyeva, Natalia; Kondratyuk, Evgeny; Konevskikh, Artem; Konyushikhin, Maxim; Kovalenko, Oleksandr; Kovalenko, Vladimir; Kowalski, Marek; Kralik, Ivan; Kravcakova, Adela; Kreis, Lukas; Krivda, Marian; Krizek, Filip; Kruger, Mario; Kryshen, Evgeny; Krzewicki, Mikolaj; Kubera, Andrew Michael; Kucera, Vit; Kuhn, Christian Claude; Kuijer, Paulus Gerardus; Kumar, Jitendra; Kumar, Lokesh; Kumar, Shyam; Kundu, Sourav; Kurashvili, Podist; Kurepin, Alexander; Kurepin, Alexey; Kuryakin, Alexey; Kushpil, Svetlana; Kvapil, Jakub; Kweon, Min Jung; Kwon, Youngil; La Pointe, Sarah Louise; La Rocca, Paola; Lai, Yue Shi; Lakomov, Igor; Langoy, Rune; Lapidus, Kirill; Lara Martinez, Camilo Ernesto; Lardeux, Antoine Xavier; Larionov, Pavel; Laudi, Elisa; Lavicka, Roman; Lea, Ramona; Leardini, Lucia; Lee, Seongjoo; Lehas, Fatiha; Lehner, Sebastian; Lehrbach, Johannes; Lemmon, Roy Crawford; Leon Monzon, Ildefonso; Levai, Peter; Li, Xiaomei; Li, Xing Long; Lien, Jorgen Andre; Lietava, Roman; Lim, Bong-hwi; Lindal, Svein; Lindenstruth, Volker; Lindsay, Scott William; Lippmann, Christian; Lisa, Michael Annan; Litichevskyi, Vladyslav; Liu, Alwina; Ljunggren, Hans Martin; Llope, William; Lodato, Davide Francesco; Loginov, Vitaly; Loizides, Constantinos; Loncar, Petra; Lopez, Xavier Bernard; Lopez Torres, Ernesto; Lowe, Andrew John; Luettig, Philipp Johannes; Luhder, Jens Robert; Lunardon, Marcello; Luparello, Grazia; Lupi, Matteo; Maevskaya, Alla; Mager, Magnus; Mahmood, Sohail Musa; Maire, Antonin; Majka, Richard Daniel; Malaev, Mikhail; Malik, Qasim Waheed; Malinina, Liudmila; Mal'kevich, Dmitry; Malzacher, Peter; Mamonov, Alexander; Manko, Vladislav; Manso, Franck; Manzari, Vito; Mao, Yaxian; Marchisone, Massimiliano; Mares, Jiri; Margagliotti, Giacomo Vito; Margotti, Anselmo; Margutti, Jacopo; Marin, Ana Maria; Markert, Christina; Marquard, Marco; Martin, Nicole Alice; Martinengo, Paolo; Martinez, Jacobb Lee; Martinez Hernandez, Mario Ivan; Martinez-garcia, Gines; Martinez Pedreira, Miguel; Masciocchi, Silvia; Masera, Massimo; Masoni, Alberto; Massacrier, Laure Marie; Masson, Erwann; Mastroserio, Annalisa; Mathis, Andreas Michael; Toledo Matuoka, Paula Fernanda; Matyja, Adam Tomasz; Mayer, Christoph; Mazzilli, Marianna; Mazzoni, Alessandra Maria; Meddi, Franco; Melikyan, Yuri; Menchaca-rocha, Arturo Alejandro; Meninno, Elisa; Mercado-perez, Jorge; Meres, Michal; Soncco Meza, Carlos; Mhlanga, Sibaliso; Miake, Yasuo; Micheletti, Luca; Mieskolainen, Matti Mikael; Mihaylov, Dimitar Lubomirov; Mikhaylov, Konstantin; Mischke, Andre; Mishra, Aditya Nath; Miskowiec, Dariusz Czeslaw; Mitra, Jubin; Mitu, Ciprian Mihai; Mohammadi, Naghmeh; Mohanty, Auro Prasad; Mohanty, Bedangadas; Khan, Mohammed Mohisin; Moreira De Godoy, Denise Aparecida; Perez Moreno, Luis Alberto; Moretto, Sandra; Morreale, Astrid; Morsch, Andreas; Muccifora, Valeria; Mudnic, Eugen; Muhlheim, Daniel Michael; Muhuri, Sanjib; Mukherjee, Maitreyee; Mulligan, James Declan; Gameiro Munhoz, Marcelo; Munning, Konstantin; Arratia Munoz, Miguel Ignacio; Munzer, Robert Helmut; Murakami, Hikari; Murray, Sean; Musa, Luciano; Musinsky, Jan; Myers, Corey James; Myrcha, Julian Wojciech; Naik, Bharati; Nair, Rahul; Nandi, Basanta Kumar; Nania, Rosario; Nappi, Eugenio; Narayan, Amrendra; Naru, Muhammad Umair; Nassirpour, Adrian Fereydon; Ferreira Natal Da Luz, Pedro Hugo; Nattrass, Christine; Rosado Navarro, Sebastian; Nayak, Kishora; Nayak, Ranjit; Nayak, Tapan Kumar; Nazarenko, Sergey; Negrao De Oliveira, Renato Aparecido; Nellen, Lukas; Nesbo, Simon Voigt; Neskovic, Gvozden; Ng, Fabian; Nicassio, Maria; Niedziela, Jeremi; Nielsen, Borge Svane; Nikolaev, Sergey; Nikulin, Sergey; Nikulin, Vladimir; Noferini, Francesco; Nomokonov, Petr; Nooren, Gerardus; Cabanillas Noris, Juan Carlos; Norman, Jaime; Nyanin, Alexander; Nystrand, Joakim Ingemar; Oh, Hoonjung; Ohlson, Alice Elisabeth; Oleniacz, Janusz; Oliveira Da Silva, Antonio Carlos; Oliver, Michael Henry; Onderwaater, Jacobus; Oppedisano, Chiara; Orava, Risto; Oravec, Matej; Ortiz Velasquez, Antonio; Oskarsson, Anders Nils Erik; Otwinowski, Jacek Tomasz; Oyama, Ken; Pachmayer, Yvonne Chiara; Pacik, Vojtech; Pagano, Davide; Paic, Guy; Palni, Prabhakar; Pan, Jinjin; Pandey, Ashutosh Kumar; Panebianco, Stefano; Papikyan, Vardanush; Pareek, Pooja; Park, Jonghan; Parkkila, Jasper Elias; Parmar, Sonia; Passfeld, Annika; Pathak, Surya Prakash; Patra, Rajendra Nath; Paul, Biswarup; Pei, Hua; Peitzmann, Thomas; Peng, Xinye; Pereira, Luis Gustavo; Pereira Da Costa, Hugo Denis Antonio; Peresunko, Dmitry Yurevich; Perez Lezama, Edgar; Peskov, Vladimir; Pestov, Yury; Petracek, Vojtech; Petrovici, Mihai; Petta, Catia; Peretti Pezzi, Rafael; Piano, Stefano; Pikna, Miroslav; Pillot, Philippe; Ozelin De Lima Pimentel, Lais; Pinazza, Ombretta; Pinsky, Lawrence; Pisano, Silvia; Piyarathna, Danthasinghe; Ploskon, Mateusz Andrzej; Planinic, Mirko; Pliquett, Fabian; Pluta, Jan Marian; Pochybova, Sona; Podesta Lerma, Pedro Luis Manuel; Poghosyan, Martin; Polishchuk, Boris; Poljak, Nikola; Poonsawat, Wanchaloem; Pop, Amalia; Poppenborg, Hendrik; Porteboeuf, Sarah Julie; Pozdniakov, Valeriy; Prasad, Sidharth Kumar; Preghenella, Roberto; Prino, Francesco; Pruneau, Claude Andre; Pshenichnov, Igor; Puccio, Maximiliano; Punin, Valery; Putschke, Jorn Henning; Raha, Sibaji; Rajput, Sonia; Rak, Jan; Rakotozafindrabe, Andry Malala; Ramello, Luciano; Rami, Fouad; Raniwala, Rashmi; Raniwala, Sudhir; Rasanen, Sami Sakari; Rascanu, Bogdan Theodor; Ratza, Viktor; Ravasenga, Ivan; Read, Kenneth Francis; Redlich, Krzysztof; Rehman, Attiq Ur; Reichelt, Patrick Simon; Reidt, Felix; Ren, Xiaowen; Renfordt, Rainer Arno Ernst; Reshetin, Andrey; Revol, Jean-pierre; Reygers, Klaus Johannes; Riabov, Viktor; Richert, Tuva Ora Herenui; Richter, Matthias Rudolph; Riedler, Petra; Riegler, Werner; Riggi, Francesco; Ristea, Catalin-lucian; Rode, Sudhir Pandurang; Rodriguez Cahuantzi, Mario; Roeed, Ketil; Rogalev, Roman; Rogochaya, Elena; Rohr, David Michael; Roehrich, Dieter; Rokita, Przemyslaw Stefan; Ronchetti, Federico; Dominguez Rosas, Edgar; Roslon, Krystian; Rosnet, Philippe; Rossi, Andrea; Rotondi, Alberto; Roukoutakis, Filimon; Roy, Christelle Sophie; Roy, Pradip Kumar; Vazquez Rueda, Omar; Rui, Rinaldo; Rumyantsev, Boris; Rustamov, Anar; Ryabinkin, Evgeny; Ryabov, Yury; Rybicki, Andrzej; Saarinen, Sampo; Sadhu, Samrangy; Sadovskiy, Sergey; Safarik, Karel; Saha, Sumit Kumar; Sahoo, Baidyanath; Sahoo, Pragati; Sahoo, Raghunath; Sahoo, Sarita; Sahu, Pradip Kumar; Saini, Jogender; Sakai, Shingo; Saleh, Mohammad Ahmad; Sambyal, Sanjeev Singh; Samsonov, Vladimir; Sandoval, Andres; Sarkar, Amal; Sarkar, Debojit; Sarkar, Nachiketa; Sarma, Pranjal; Sas, Mike Henry Petrus; Scapparone, Eugenio; Scarlassara, Fernando; Schaefer, Brennan; Scheid, Horst Sebastian; Schiaua, Claudiu Cornel; Schicker, Rainer Martin; Schmidt, Christian Joachim; Schmidt, Hans Rudolf; Schmidt, Marten Ole; Schmidt, Martin; Schmidt, Nicolas Vincent; Schukraft, Jurgen; Schutz, Yves Roland; Schwarz, Kilian Eberhard; Schweda, Kai Oliver; Scioli, Gilda; Scomparin, Enrico; Sefcik, Michal; Seger, Janet Elizabeth; Sekiguchi, Yuko; Sekihata, Daiki; Selyuzhenkov, Ilya; Senosi, Kgotlaesele; Senyukov, Serhiy; Serradilla Rodriguez, Eulogio; Sett, Priyanka; Sevcenco, Adrian; Shabanov, Arseniy; Shabetai, Alexandre; Shahoyan, Ruben; Shaikh, Wadut; Shangaraev, Artem; Sharma, Anjali; Sharma, Ankita; Sharma, Meenakshi; Sharma, Natasha; Sheikh, Ashik Ikbal; Shigaki, Kenta; Shimomura, Maya; Shirinkin, Sergey; Shou, Qiye; Shtejer Diaz, Katherin; Sibiryak, Yury; Siddhanta, Sabyasachi; Sielewicz, Krzysztof Marek; Siemiarczuk, Teodor; Silvermyr, David Olle Rickard; Simatovic, Goran; Simonetti, Giuseppe; Singaraju, Rama Narayana; Singh, Ranbir; Singh, Randhir; Singhal, Vikas; Sarkar - Sinha, Tinku; Sitar, Branislav; Sitta, Mario; Skaali, Bernhard; Slupecki, Maciej; Smirnov, Nikolai; Snellings, Raimond; Snellman, Tomas Wilhelm; Song, Jihye; Soramel, Francesca; Sorensen, Soren Pontoppidan; Sozzi, Federica; Sputowska, Iwona Anna; Stachel, Johanna; Stan, Ionel; Stankus, Paul; Stenlund, Evert Anders; Stocco, Diego; Storetvedt, Maksim Melnik; Strmen, Peter; Alarcon Do Passo Suaide, Alexandre; Sugitate, Toru; Suire, Christophe Pierre; Suleymanov, Mais Kazim Oglu; Suljic, Miljenko; Sultanov, Rishat; Sumbera, Michal; Sumowidagdo, Suharyo; Suzuki, Ken; Swain, Sagarika; Szabo, Alexander; Szarka, Imrich; Tabassam, Uzma; Takahashi, Jun; Tambave, Ganesh Jagannath; Tanaka, Naoto; Tarhini, Mohamad; Tariq, Mohammad; Tarzila, Madalina-gabriela; Tauro, Arturo; Tejeda Munoz, Guillermo; Telesca, Adriana; Terrevoli, Cristina; Teyssier, Boris; Thakur, Dhananjaya; Thakur, Sanchari; Thomas, Deepa; Thoresen, Freja; Tieulent, Raphael Noel; Tikhonov, Anatoly; Timmins, Anthony Robert; Toia, Alberica; Topilskaya, Nataliya; Toppi, Marco; Rojas Torres, Solangel; Tripathy, Sushanta; Trogolo, Stefano; Trombetta, Giuseppe; Tropp, Lukas; Trubnikov, Victor; Trzaska, Wladyslaw Henryk; Trzcinski, Tomasz Piotr; Trzeciak, Barbara Antonina; Tsuji, Tomoya; Tumkin, Alexandr; Turrisi, Rosario; Tveter, Trine Spedstad; Ullaland, Kjetil; Umaka, Ejiro Naomi; Uras, Antonio; Usai, Gianluca; Utrobicic, Antonija; Vala, Martin; Van Hoorne, Jacobus Willem; Van Leeuwen, Marco; Vande Vyvre, Pierre; Varga, Dezso; Diozcora Vargas Trevino, Aurora; Vargyas, Marton; Varma, Raghava; Vasileiou, Maria; Vasiliev, Andrey; Vauthier, Astrid; Vazquez Doce, Oton; Vechernin, Vladimir; Veen, Annelies Marianne; Vercellin, Ermanno; Vergara Limon, Sergio; Vermunt, Luuk; Vernet, Renaud; Vertesi, Robert; Vickovic, Linda; Viinikainen, Jussi Samuli; Vilakazi, Zabulon; Villalobos Baillie, Orlando; Villatoro Tello, Abraham; Vinogradov, Alexander; Virgili, Tiziano; Vislavicius, Vytautas; Vodopyanov, Alexander; Volkl, Martin Andreas; Voloshin, Kirill; Voloshin, Sergey; Volpe, Giacomo; Von Haller, Barthelemy; Vorobyev, Ivan; Voscek, Dominik; Vranic, Danilo; Vrlakova, Janka; Wagner, Boris; Wang, Hongkai; Wang, Mengliang; Watanabe, Yosuke; Weber, Michael; Weber, Steffen Georg; Wegrzynek, Adam; Weiser, Dennis Franz; Wenzel, Sandro Christian; Wessels, Johannes Peter; Westerhoff, Uwe; Whitehead, Andile Mothegi; Wiechula, Jens; Wikne, Jon; Wilk, Grzegorz Andrzej; Wilkinson, Jeremy John; Willems, Guido Alexander; Williams, Crispin; Willsher, Emily; Windelband, Bernd Stefan; Witt, William Edward; Xu, Ran; Yalcin, Serpil; Yamakawa, Kosei; Yano, Satoshi; Yin, Zhongbao; Yokoyama, Hiroki; Yoo, In-kwon; Yoon, Jin Hee; Yurchenko, Volodymyr; Zaccolo, Valentina; Zaman, Ali; Zampolli, Chiara; Correa Zanoli, Henrique Jose; Zardoshti, Nima; Zarochentsev, Andrey; Zavada, Petr; Zavyalov, Nikolay; Zbroszczyk, Hanna Paulina; Zhalov, Mikhail; Zhang, Xiaoming; Zhang, Yonghong; Zhang, Zuman; Zhao, Chengxin; Zherebchevskii, Vladimir; Zhigareva, Natalia; Zhou, Daicui; Zhou, You; Zhou, Zhuo; Zhu, Hongsheng; Zhu, Jianhui; Zhu, Ya; Zichichi, Antonino; Zimmermann, Markus Bernhard; Zinovjev, Gennady; Zmeskal, Johann; Zou, Shuguang

    2018-01-01

    Inclusive J/$\\psi$ production is studied in Xe-Xe interactions at a centre-of-mass energy per nucleon pair of $\\sqrt{s_{NN}}$ = 5.44 TeV, using the ALICE detector at the CERN LHC. The J/$\\psi$ meson is reconstructed via its decay into a muon pair, in the centre-of-mass rapidity interval 2.5 < y < 4 and down to zero transverse momentum. In this Letter, the nuclear modification factors $R_{AA}$ for inclusive J/$\\psi$, measured in the centrality range 0-90% as well as in the centrality intervals 0-20% and 20-90% are presented. The $R_{AA}$ values are compared to previously published results for Pb-Pb collisions at $\\sqrt{s_{NN}}$ = 5.02 TeV and to the calculation of a transport model. A good agreement is found between Xe-Xe and Pb-Pb results as well as between data and the model.

  12. Beta-gamma counting system for Xe fission products

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; Perkins, R.W.

    1998-01-01

    A beta-gamma coincidence counting system has been developed for automated analysis of Xe gas samples separated from air. The Xe gas samples are contained in a cylindrical plastic scintillator cell located between two NaI(Tl) scintillation detectors. The X-ray and gamma spectra gated by coincident events in the plastic scintillator cell are recorded for each NaI(Tl) crystal. The characteristic signatures of the 131m Xe, 133g Xe, 133m Xe, and 135g Xe isotopes of interest for nuclear test-ban verification as well as the procedures and results of absolute efficiency measurements are described. A NaI(Tl) crystal with provision for 4 sample cells has been implemented for the system to be deployed in the field. Examples of data on ambient air samples in New York City obtained with the field prototype are presented. (author)

  13. Plunger lifetime measurements in {sup 128}Xe using Coulomb excitation in inverse kinematics

    Energy Technology Data Exchange (ETDEWEB)

    Rother, Wolfram; Dewald, Alfred; Ilie, Gabriela; Pissulla, Thomas; Melon, Barbara; Jolie, Jan; Pascovici, Gheorghe; Zell, Karl-Oskar [IKP, Universitaet zu Koeln, Koeln (Germany); Julin, Rauno; Jones, Peter; Greenless, Paul; Rahkila, Panu; Scholey, Cath [JYFL, University of Jyvaeskylae, Jyvaeskylae (Finland); Harissopulos, Sotirios; Lagoyannis, Anastasios; Konstantinopoulos, T. [INP, N.C.S.R. ' ' Demokritos' ' , Athens (Greece); Grahn, Tuomas [JYFL, University of Jyvaeskylae, Jyvaeskylae (Finland)]|[Oliver Lodge Lab., University of Liverpool, Liverpool (United Kingdom); Balabanski, Dimiter [INRNE, Sofia (Bulgaria)

    2008-07-01

    We report on an experiment using Coulomb excitation in inverse kinematics in combination with the plunger technique for measuring lifetimes of excited states of the projectile. Aside from the investigation of E(2) features in {sup 128}Xe, the aim was to explore the special features of such experiments which are also suited to be used with radioactive beams. The measurement was performed at the JYFL with the Koeln coincidence plunger device and the JuroGam spectrometer using a {sup 128}Xe beam impinging on a {sup nat}Fe target at a beam energy of 525 MeV. Recoils were detected by means of 32 solar cells placed at extrem forward angles. Recoil-gated {gamma}-singles and {gamma}{gamma}-coincidences were measured at different target-degrader distances. Details of the experiment and first results are presented.

  14. Study of the spallation reactions 136Xe + p and 136Xe + 12C at 1 GeV per nucleon at the GSI facility (Darmstadt, Germany)

    International Nuclear Information System (INIS)

    Gorbinet, T.

    2011-11-01

    The collision of 136 Xe with a proton and with 12 C at 1 GeV per nucleon of projectile kinetic energy in the center of mass has been studied in inverse kinematics using the SPALADIN experimental setup at the GSI facility. This manuscript describes the analysis of these collisions realized in spring 2009. The detection in coincidence of the final state fragments (projectile residues, neutrons and light charged fragments) with a large geometrical efficiency is provided by the inverse kinematics combined with a large aperture dipole magnet and large detectors. Such a coincidence, measured on an event basis, allows selecting, in a model independent way, the pre-fragment, the excited nuclear system formed after the intranuclear cascade as a function of its excitation energy. Hence, we were able to study the evolution of the pre-fragment deexcitation mechanism (evaporation of light particles, asymmetric binary decay, multiple fragmentation..) as a function of its excitation energy. The data of the 136 Xe + p reaction have been compared mainly to three deexcitation models (SMM, GEMINI++ and ABLA07) coupled to the intranuclear cascade code INCL4. Despite the relatively good and global agreement between these models and our data, significant discrepancies appeared concerning in particular the production of intermediate mass fragments (IMF). Comparison between the 136 Xe + 12 C and the 136 Xe + p data exhibits an important similarity in the deexcitation of the pre-fragments. This suggests that the nuclear cascade leads, for both targets, to similar pre-fragment types in the range of excitation energy (0 to 4 MeV per nucleon) common to both reactions. Higher excitation energies, reached only in the 136 Xe + 12 C reaction, show a qualitative difference in the deexcitation of the pre-fragment, with much higher multiplicities of IMF per event, increasing with the excitation energy. (author)

  15. 129 Xe NMR Relaxation-Based Macromolecular Sensing

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Muller D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Dao, Phuong [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Jeong, Keunhong [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Slack, Clancy C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Vassiliou, Christophoros C. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Finbloom, Joel A. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Francis, Matthew B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Wemmer, David E. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Physical Biosciences Division; Pines, Alexander [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry

    2016-07-29

    A 129Xe NMR relaxation-based sensing approach is reported on that exploits changes in the bulk xenon relaxation rate induced by slowed tumbling of a cryptophane-based sensor upon target binding. The amplification afforded by detection of the bulk dissolved xenon allows sensitive detection of targets. The sensor comprises a xenon-binding cryptophane cage, a target interaction element, and a metal chelating agent. Xenon associated with the target-bound cryptophane cage is rapidly relaxed and then detected after exchange with the bulk. Here we show that large macromolecular targets increase the rotational correlation time of xenon, increasing its relaxation rate. Upon binding of a biotin-containing sensor to avidin at 1.5 μM concentration, the free xenon T2 is reduced by a factor of 4.

  16. /sup 133/Xe and /sup 135/Xe interference with in vivo low-energy measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, N; Lo Sasso, T; Lei, W [New York Univ., NY (USA). Inst. of Environmental Medicine

    1980-03-01

    Fission product /sup 133/Xe and /sup 135/Xe are released to the atmosphere during normal reactor operation. With increasing numbers of nuclear power stations there will be an increase in the ambient level of these isotopes. They do not present an appreciable long-term health hazard because of their inert nature and relatively short half-lives. However, their presence in the air of a whole-body counter may interfere significantly with in vivo low-energy photon counting procedures by contributing to the background count-rate in the energy region below 300 keV. This applies particularly to lung and whole-body measurements with dual thin crystal NaI(Tl)-CsI(Tl) scintillation detectors for actinide nuclides. It is important, therefore, that gamma spectroscopists should be aware of the possible presence of /sup 133/Xe and /sup 135/Xe in the air of their whole-body counting facilities, particularly if these are near to reactors and do not have traps for removal of inert gases from their air supplies.

  17. Molecular dynamics simulations of adsorption and diffusion of Xe on bare and Xe covered Pt(111)

    NARCIS (Netherlands)

    Jong, de F.; Jansen, A.P.J.

    1994-01-01

    Molecular dynamics simulations are used to calculate adsorption probabilities and diffusion coefficients of Xe on Pt(111) and Xe/Pt(111). Experimental trends are reproduced. The adsorption mechanism is found to be the modified Kisliuk model, with the addition of direct and indirect insertion in the

  18. Preliminary investigations for technology assessment of 99Mo production from LEU [low enriched uranium] targets

    International Nuclear Information System (INIS)

    Vandegrift, G.F.; Chaiko, D.J.; Heinrich, R.R.; Kucera, E.T.; Jensen, K.J.; Poa, D.S.; Varma, R.; Vissers, D.R.

    1986-11-01

    This paper presents the results of preliminary studies on the effects of substituting low enriched uranium (LEU) for highly enriched uranium (HEU) in targets for the production of fission product 99 Mo. Issues that were addressed are: (1) purity and yield of the 99 Mo//sup 99m/Tc product, (2) fabrication of LEU targets and related concerns, and (3) radioactive waste. Laboratory experimentation was part of the efforts for issues (1) and (2); thus far, radioactive waste disposal has only been addressed in a paper study. Although the reported results are still preliminary, there is reason to be optimistic about the feasibility of utilizing LEU targets for 99 Mo production. 37 refs., 1 fig., 5 tabs

  19. SEP-Kr and SEP-Xe in Lunar Ilmenite and the Ar/Kr/Xe Ratio in the Solar Wind

    Science.gov (United States)

    Wieler, R.; Baur, H.; Signer, P.

    1992-07-01

    We analyzed all five noble gases in an ilmenite sample from lunar soil 71501 by closed system stepped etching (CSSE), thus extending our CSSE studies of solar noble gases (Wieler et al., 1986; Benkert et al., 1988) to Kr and Xe. He, Ne, Ar isotopes: We observe the familiar presence of two solar noble gas components: step 1 shows ^4He/^3He = 2250, ^20Ne/^22Ne = 13.8, and ^36Ar/^38Ar=5.46. The first two ratios are essentially identical to modern solar wind values (SWC; Geiss, 1973), indicating an isotopically unfractionated SW noble gas reservoir in lunar ilmenite. The Ne data-points of later steps fall on a straight line and reach the SEP-Ne point (^20Ne/^22Ne = 11.3). The slope of this line indicates mass dependent fractionation between SW-Ne and SEP-Ne. SEP-He (^4He/^3He = 4650 +-100) and SEP-Ar (^36Ar/^38Ar = 4.89+-0.05) are also observed (latter two numbers slightly revised compared to Wieler et al., 1992). Kr, Xe isotopes: Kr in those two steps that release pure SW-Ne is very slightly lighter than atmospheric Kr (^86Kr/^84Kr = 0.3041; see also Wieler et al., 1992). We interpret this to be SW-Kr in soil 71501. Steps containing (isotopically heavier) SEP-Ne likewise release heavier Kr, interpreted accordingly as SEP-Kr (^86Kr/^84Kr = 0.323). Similarly, a light Xe component is released first (SW-Xe, ^136Xe/^132Xe = 0.3003), followed by heavier SEP-Xe (^136Xe/^132Xe = 0.319). The data are consistent with both Kr and Xe in SW and SEP components to be related by mass fractionation. The relation first proposed by Benkert et al. (1988) between a ratio R(m(sub)2,m(sub)1) of two isotopes with masses m(sub)2>m(sub)1 in SW and SEP now holds for all five noble gases: (R(sub)SW-R(sub)SEP)/R(sub)SW = (2+-0.13)*(m(sub)2- m(sub)1)/m(sub)2. Since m(sub)2~m(sub)1, this relation may also be written as: R(sub)SEP/R(sub)SW ~ (m(sub)1/m(sub)2)^2 (Geiss and Bochsler, 1991). Element ratios: ^4He/^36Ar and ^20Ne/^36Ar rise from values several times below SWC to essentially SWC ratios in

  20. Individual microRNAs (miRNAs) display distinct mRNA targeting "rules".

    Science.gov (United States)

    Wang, Wang-Xia; Wilfred, Bernard R; Xie, Kevin; Jennings, Mary H; Hu, Yanling Hu; Stromberg, Arnold J; Nelson, Peter T

    2010-01-01

    MicroRNAs (miRNAs) guide Argonaute (AGO)-containing microribonucleoprotein (miRNP) complexes to target mRNAs.It has been assumed that miRNAs behave similarly to each other with regard to mRNA target recognition. The usual assumptions, which are based on prior studies, are that miRNAs target preferentially sequences in the 3'UTR of mRNAs,guided by the 5' "seed" portion of the miRNAs. Here we isolated AGO- and miRNA-containing miRNPs from human H4 tumor cells by co-immunoprecipitation (co-IP) with anti-AGO antibody. Cells were transfected with miR-107, miR-124,miR-128, miR-320, or a negative control miRNA. Co-IPed RNAs were subjected to downstream high-density Affymetrix Human Gene 1.0 ST microarray analyses using an assay we validated previously-a "RIP-Chip" experimental design. RIP-Chip data provided a list of mRNAs recruited into the AGO-miRNP in correlation to each miRNA. These experimentally identified miRNA targets were analyzed for complementary six nucleotide "seed" sequences within the transfected miRNAs. We found that miR-124 targets tended to have sequences in the 3'UTR that would be recognized by the 5' seed of miR-124, as described in previous studies. By contrast, miR-107 targets tended to have 'seed' sequences in the mRNA open reading frame, but not the 3' UTR. Further, mRNA targets of miR-128 and miR-320 are less enriched for 6-mer seed sequences in comparison to miR-107 and miR-124. In sum, our data support the importance of the 5' seed in determining binding characteristics for some miRNAs; however, the "binding rules" are complex, and individual miRNAs can have distinct sequence determinants that lead to mRNA targeting.

  1. Centrality determination using the Glauber model in Xe-Xe collisions at $\\sqrt{s_{\\rm NN}} = 5.44$ TeV

    CERN Document Server

    2018-01-01

    This document describes the methods used by the ALICE Collaboration for determining the centrality of Xe-Xe collisions at $\\sqrt{s_{\\rm NN}} = 5.44$ TeV at the LHC within the Glauber model. The half-density radius $R$ and the diffusivity $a$ describing the Xe-129 nucleus with a 2-parameter Fermi distribution have been derived from a recent electron scattering measurement for the Xe-132 nucleus. The deformation parameter $\\beta$ has been derived by an interpolation between measured deformation parameters for the even-$A$ Xe isotopes. The inelastic nucleon-nucleon cross-section at $\\sqrt{s_{\\rm NN}} = 5.44$ TeV has been estimated by interpolation of pp data at different center-of-mass energies. The particle multiplicity per nucleon-nucleon collision has been parameterized by a negative binomial distribution (NBD) and a number of independently emitting sources (ancestors) given by a linear combination of $N_{\\rm part}$ and $N_{\\rm coll}$. The NBD parameters $\\mu$ and $k$ and the ancestor parameter $f$ are then...

  2. Xe-129 NMR chemical shift in Xe@C-60 calculated at experimental conditions: Essential role of the relativity, dynamics, and explicit solvent

    Czech Academy of Sciences Publication Activity Database

    Standara, Stanislav; Kulhánek, P.; Marek, R.; Straka, Michal

    2013-01-01

    Roč. 34, č. 22 (2013), s. 1890-1898 ISSN 0192-8651 R&D Projects: GA ČR GA203/09/2037; GA ČR GA13-03978S Grant - others:7th European Community Framework Program(XE) FP7-286154; CEITEC-Central European Institute of Technology (European Regional Development)(XE) CZ.1.05/1.1.00/02.0068; Operational Program Research and Development for Innovations(XE) CZ.1.05/3.2.00/08.0144 Institutional support: RVO:61388963 Keywords : Xe-129 NMR * Xe@C-60 * dynamical averaging * explicit solvent * relativistic effects Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.601, year: 2013

  3. Production of pure 133mXe for CTBTO

    Science.gov (United States)

    Peräjärvi, K.; Eronen, T.; Gorelov, D.; Hakala, J.; Jokinen, A.; Kettunen, H.; Kolhinen, V.; Laitinen, M.; Moore, I. D.; Penttilä, H.; Rissanen, J.; Saastamoinen, A.; Toivonen, H.; Turunen, J.; Äystö, J.

    2014-01-01

    Underground nuclear weapon detonations release gaseous species into the atmosphere. The most interesting isotopes/isomers from the detection point of view are 131mXe, 133mXe, 133Xe and 135Xe. We have developed a method that employs high-precision Penning trap mass spectrometry at the JYFLTRAP facility, the University of Jyväskylä, to produce pure calibration samples of these isotopes/isomers. Among developments this work required a new mass resolution record of a few parts-per-million. Here the status and future plans of the project are reviewed.

  4. High spin {gamma}-ray spectroscopy of {sup 121,122}Xe

    Energy Technology Data Exchange (ETDEWEB)

    Timmers, H [Liverpool Univ. (United Kingdom). Oliver Lodge Lab.; [Department of Physics, SUNY at Stony Brook, NY (United States); Riley, M A; Hanna, F; Mullins, S M; Sharpey-Schafer, J F [Liverpool Univ. (United Kingdom). Oliver Lodge Lab.; Hughes, J R; Fossan, D B; Liang, Y; Ma, R; Xu, N [Department of Physics, SUNY at Stony Brook, NY (United States); Simpson, J; Bentley, M A [Daresbury Lab. (United Kingdom); Bengtsson, T [Lund Univ. (Sweden). Dept. of Mathematical Physics; Wyss, R [Institute for Heavy Ion Research, Oak Ridge, TN (United States)

    1992-08-01

    High-spin states have been populated in {sup 121,122}Xe using the reactions {sup 108}Pd({sup 16}O,3n){sup 121}Xe at 65 MeV and {sup 96}Zr({sup 30}Si,4n/5n){sup 122}Xe/{sup 121}Xe at 135 MeV. Coincident {gamma} rays following the neutron evaporation were detected by six Compton-suppressed Ge detectors and the TESSA3 array respectively. The level structure of {sup 121}Xe and {sup 122}Xe has been extended up to 47/2 {Dirac_h} and 32 {Dirac_h} respectively. In {sup 121}Xe a coupled band was found feeding the 19/2{sup -} level. In {sup 122}Xe several decays are suggested to be a sequence of stretched E2 quadrupole transitions connecting states of positive parity. While in {sup 121}Xe this phenomenon was not observed, at high spin a phase transition from prolate collective rotation to oblate single particle excitation was detected in {sup 122}Xe. For the new, probably positive parity side band in{sup 122}Xe a four quasi-neutron or a two quasi-proton configuration of h{sub 11/2} quasi-nucleons might be considered. The positive parity high spin structure in {sup 122}Xe contains three I{sup {pi}} = 22{sup +} states of different character. This is predicted by TRS (total Routhian surface) calculations, which identify these states as two shapes with predominantly prolate collective characteristic and the third as an oblate single particle configuration. 12 refs., 3 figs.

  5. Formation of (Xe2H)* centers in solid Xe via recombination: nonstationary luminescence and 'internal electron emission'

    International Nuclear Information System (INIS)

    Savchenko, E.V.; Khyzhniy, I.V.; Uyutov, S.A.; Gumenchuk, G.B.; Ponomarev, A.N.; Bondybey, V.E.; Beyer, M.K.

    2010-01-01

    The formation of excimers (Xe 2 H) * in solid Xe doped with molecular hydrogen under electron beam is studied using the original two-stage technique of nonstationary (NS) cathodoluminescence (CL) in combination with the current activation spectroscopy method - thermally stimulated exoelectron emission (TSEE). Charged species were generated using a high-density electron beam. The species produced were then probed with a low density beam on gradual sample heating. The near UV emission of the (Xe 2 H) * was used to monitor the neutralization process. It is found that the temperature behavior of the NS CL band of (Xe 2 H) * clearly correlates with the yield of TSEE measured after identical pre-irradiation of the sample. The fingerprints of the thermally stimulated detrapping of electrons - 'internal electron emission' in the spectrum of NS CL point to the essential role of neutralization reaction in the stability of the proton solvated by rare-gas atoms.

  6. Modification of the Xe 4d giant resonance by the C60 shell in molecular Xe at C60

    International Nuclear Information System (INIS)

    Amusia, M. Ya.; Baltenkov, A. S.; Chernysheva, L. V.; Felfli, Z.; Msezane, A. Z.

    2006-01-01

    It is demonstrated that in photoabsorption of the 4d 10 subshell of a Xe atom in molecular Xe at C 60 , the 4d giant resonance that characterizes the isolated Xe atom is distorted significantly. The reflection of photoelectron waves by the C 60 shell leads to profound oscillations in the photoionization cross section such that the Xe giant resonance is transformed into four strong peaks. Similarly, the angular anisotropy parameters, both dipole and nondipole, are also modified. The method of calculation is based on the approximation of the C 60 shell by an infinitely thin bubble potential that leaves the sum rule for the 4d-electrons almost unaffected, but noticeably modifies the dipole polarizability of the 4d-shell

  7. Development of Industrial-Scale Fission 99Mo Production Process Using Low Enriched Uranium Target

    Directory of Open Access Journals (Sweden)

    Seung-Kon Lee

    2016-06-01

    Full Text Available Molybdenum-99 (99Mo is the most important isotope because its daughter isotope, technetium-99m (99mTc, has been the most widely used medical radioisotope for more than 50 years, accounting for > 80% of total nuclear diagnostics worldwide. In this review, radiochemical routes for the production of 99Mo, and the aspects for selecting a suitable process strategy are discussed from the historical viewpoint of 99Mo technology developments. Most of the industrial-scale 99Mo processes have been based on the fission of 235U. Recently, important issues have been raised for the conversion of fission 99Mo targets from highly enriched uranium to low enriched uranium (LEU. The development of new LEU targets with higher density was requested to compensate for the loss of 99Mo yield, caused by a significant reduction of 235U enrichment, from the conversion. As the dramatic increment of intermediate level liquid waste is also expected from the conversion, an effective strategy to reduce the waste generation from the fission 99Mo production is required. The mitigation of radioxenon emission from medical radioisotope production facilities is discussed in relation with the monitoring of nuclear explosions and comprehensive nuclear test ban. Lastly, the 99Mo production process paired with the Korea Atomic Energy Research Institute's own LEU target is proposed as one of the most suitable processes for the LEU target.

  8. Asymmetric output profile of Xe Laser

    NARCIS (Netherlands)

    Blok, F.J.; Rubin, P.L.; Verschuur, Jeroen W.J.; Witteman, W.J.

    2001-01-01

    A new set of asymmetric modes was recently revealed in a Xe slab laser with pronounced lens effects originating from gas heating in the discharge. The appearance of these modes is a threshold effect. Their domain of existence in the Xe laser is discussed. It is shown that mode competition can result

  9. High-j neutron excitations outside 136Xe

    Science.gov (United States)

    Talwar, R.; Kay, B. P.; Mitchell, A. J.; Adachi, S.; Entwisle, J. P.; Fujita, Y.; Gey, G.; Noji, S.; Ong, H. J.; Schiffer, J. P.; Tamii, A.

    2017-08-01

    The ν 0 h9 /2 and ν 0 i13 /2 strength at 137Xe, a single neutron outside the N =82 shell closure, has been determined using the 136Xe(α ,3He)137Xe reaction carried out at 100 MeV. We confirm the recent observation of the second 13 /2+ state and reassess previous data on the 9 /2- states, obtaining spectroscopic factors. These new data provide additional constraints on predictions of the same single-neutron excitations at 133Sn.

  10. Methylation-mediated silencing of miR-124 facilitates chondrogenesis by targeting NFATc1 under hypoxic conditions.

    Science.gov (United States)

    Gong, Ming; Liang, Tangzhao; Jin, Song; Dai, Xuejun; Zhou, Zhiyu; Gao, Manman; Huang, Sheng; Luo, Jiaquan; Zou, Lijin; Zou, Xuenong

    2017-01-01

    Chondrogenic differentiation of mesenchymal stem cells is regulated by many different pathways. Recent studies have established that hypoxia and epigenetic alterations potently affect expression of chondrogenesis marker genes. Sox9 is generally regarded as a master regulator of chondrogenesis and microRNA-124 (miRNA-124) regulates gene expression in murine bone marrow-derived mesenchymal stem cells. Therefore, in this study we investigated whether epigenetic regulation of miRNA-124 could affect the expression of Sox9 and thereby regulate chondrogenesis. A cell pellet culture model was used to induce chondrogenesis in C3H10T1/2 cells under hypoxic conditions (2% O 2 ) to determine the effects of hypoxia on miR-124 expression and DNA methylation. The expression of miR-124 was significantly downregulated under hypoxic conditions compared to normoxic conditions (21% O 2 ). The expression of chondrogenesis marker genes was significantly increased under hypoxic conditions. Bisulfite sequencing of the CpG islands in the promoter region of miR-124-3 showed that CpG methylation was significantly increased under hypoxic conditions. Treating the cells with the DNA demethylating agent 5'-AZA significantly increased miR-124 expression and decreased expression of markers of chondrogenesis. Overexpressing miR-124 under hypoxic conditions inhibited NFATc1 reporter activity. NFATc1 was shown to bind to the promoter region of Sox9. Taken together, our data provide evidence that miR-124 acts as an inhibitor of NFATc1. Under hypoxic conditions when miR-124 is downregulated by methylation of CpG islands in the promoter, NFATc1 can bind to the Sox9 promoter and induce the expression of Sox9 leading to chondrogenesis. These results support the role of epigenetic regulation in establishing and maintaining a chondrogenic phenotype.

  11. The role of enriched isotopes in fundamental physical investigations

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Skorynin, G.M.; Shubin, A.N.

    2002-01-01

    Development of physics of elementary particles, astrophysics and cosmology at present is characterized by continuous increase of a number of fundamental problems experimental investigation of which needs significant quantities of enriched isotopes of high purity. Study of solar neutrino radiation, search of nonluminous matter, detection of neutrino-free double beta-decay are the most priority investigations in the world at present. In the report the most actual experiments with enriched isotopes ( 136 Xe, 100 Mo, 76 Ge, 116 Cd, 82 Se and some others) are discussed together with basic requirements for isotopes and possibilities on operating time of the Industrial Joining Electrochemical plant [ru

  12. Charged-particle nuclear modification factors in XeXe collisions at $\\sqrt{s_{\\mathrm{NN}}}=5.44~\\mathrm{TeV}$

    CERN Document Server

    CMS Collaboration

    2018-01-01

    The differential yields of charged particles having pseudorapidity within $|\\eta|6~\\mathrm{GeV}$. However, the suppression in XeXe events is slightly greater than in PbPb collisions when comparing selections having a similar number of participating nucleons.

  13. Experimental ion mobility measurements in Xe-CF4 mixtures

    Science.gov (United States)

    Cortez, A. F. V.; Kaja, M. A.; Escada, J.; Santos, M. A. G.; Veenhof, R.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2018-04-01

    In this paper we present the results of the ion mobility measurements made in gaseous mixtures of xenon with carbon tetrafluoride (Xe-CF4) for pressures ranging from 6 to 10 Torr (8-10.6 mbar) and for low reduced electric fields in the 10 to 25 Td range (2.4-6.1 kVṡcm‑1ṡbar‑1), at room temperature. The time-of-arrival spectra revealed one or two peaks depending on the gas relative abundances, which were attributed to CF3+ and to Xe2+ ions. However, for Xe concentrations above 60%, only one peak remains (Xe2+). The reduced mobilities obtained from the peak centroid of the time-of-arrival spectra are presented for Xe concentrations in the 5%-95% range.

  14. Stable Chloro- and Bromoxenate Cage Anions; [X3(XeO3)3]3- and [X4(XeO3)4]4- (X = Cl or Br).

    Science.gov (United States)

    Goettel, James T; Haensch, Veit G; Schrobilgen, Gary J

    2017-06-28

    The number of isolable compounds which contain different noble-gas-element bonds is limited for xenon and even more so for krypton. Examples of Xe-Cl bonds are rare, and prior to this work, no Xe-Br bonded compound had been isolated in macroscopic quantities. The syntheses, isolation, and characterization of the first compounds to contain Xe-Br bonds and their chlorine analogues are described in the present work. The reactions of XeO 3 with [N(CH 3 ) 4 ]Br and [N(C 2 H 5 ) 4 ]Br have provided two bromoxenate salts, [N(C 2 H 5 ) 4 ] 3 [Br 3 (XeO 3 ) 3 ] and [N(CH 3 ) 4 ] 4 [Br 4 (XeO 3 ) 4 ], in which the cage anions have Xe-Br bond lengths that range from 3.0838(3) to 3.3181(8) Å. The isostructural chloroxenate anions (Xe-Cl bond lengths, 2.9316(2) to 3.101(4) Å) were synthesized by analogy with their bromine analogues. The bromo- and chloroxenate salts are stable in the atmosphere at room temperature and were characterized in the solid state by Raman spectroscopy and low-temperature single-crystal X-ray diffraction, and in the gas phase by quantum-chemical calculations. They are the only known examples of cage anions that contain a noble-gas element. The Xe-Br and Xe-Cl bonds are very weakly covalent and can be viewed as σ-hole interactions, similar to those encountered in halogen bonding. However, the halogen atoms in these cases are valence electron lone pair donors, and the σ* Xe-O orbitals are lone pair acceptors.

  15. Level structures of 119Xe, 121Xe excited in (12C,3nγ) reactions and analysis of the hsub(11/2) bands in the IBF model

    International Nuclear Information System (INIS)

    Barci, V.; Gizon, J.; Gizon, A.

    1982-02-01

    Levels in 119 Xe, 121 Xe excited by the reactions 110 Cd, 112 Cd( 12 C,3nγ) 119 Xe, 121 Xe have been studied by in-beam γ-ray spectroscopic techniques. Several bands have been observed: hsub(11/2) and gsub(7/2) in 119 Xe, 121 Xe, a decoupled one in 121 Xe. A new level structure in 119 Xe found for the first time is assigned as the gsub(9/2) band generated by one hole in the gsub(9/2) neutron shell. The connections between these bands have been fixed in both nuclei. A detailed analysis is made for the hsub(11/2) level structure. An interpretation is given in terms of the interacting boson-fermion model where hsub(11/2), fsub(7/2) and hsub(9/2) fermion configurations are included

  16. Predictions for multiplicities and flow harmonics in 5.44 TeV Xe+Xe collisions at the CERN Large Hadron Collider

    Science.gov (United States)

    Eskola, K. J.; Niemi, H.; Paatelainen, R.; Tuominen, K.

    2018-03-01

    We present the event-by-event next-to-leading-order perturbative-QCD + saturation + viscous hydrodynamics (EKRT) model predictions for the centrality dependence of the charged hadron multiplicity in the pseudorapidity interval |η |≤0.5 , and for the centrality dependence of the charged hadron flow harmonics vn{2 } obtained from two-particle cumulants, in √{sN N}=5.44 TeV Xe+Xe collisions at the CERN Large Hadron Collider. Our prediction for the 0-5 % central charged multiplicity is d Nch/d η =1218 ±46 . We also predict vn{2 } in Xe+Xe collisions to increase more slowly from central towards peripheral collisions than those in a Pb+Pb system. We find that at 10 ,⋯,50 % centralities v2{2 } is smaller and v3{2 } is larger than in the Pb+Pb system while v4{2 } is of the same magnitude in both systems. We also find that the ratio of flow harmonics in Xe+Xe collisions and in Pb+Pb collisions shows a slight sensitivity to the temperature dependence of the shear-viscosity-to-entropy ratio. As we discuss here, the new nuclear mass-number systematics especially in the flow harmonics serves as a welcome further constraint for describing the space-time evolution of a heavy-ion system and for determining the shear viscosity and other transport properties of strongly interacting matter.

  17. Search for a permanent Xe-electric dipole moment

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, Stefan [Institut fuer Physik, Universitaet Mainz (Germany); Collaboration: MIXed-Collaboration

    2016-07-01

    A permanent electric dipole moment (EDM) of the isotope {sup 129}Xe would imply a breakdown of both parity P and time-reversal symmetry T and, through the CPT theorem, a breakdown in CP, the combined symmetries of charge conjugation C and parity P. Our goal is to improve the present experimental limit (d{sub Xe}<3.10{sup -27} ecm) by about three orders of magnitude. The most precise EDM limit on diamagnetic atoms was measured on {sup 199}Hg (d{sub Hg}<3.1.10{sup -29} ecm). To get more stringent limits, we perform a {sup 3}He/{sup 129}Xe clock comparison experiment with the detection of free spin precession of gaseous, nuclear polarized {sup 3}He or {sup 129}Xe samples with a SQUID as magnetic flux detector. The precession of co-located {sup 3}He/{sup 129}Xe nuclear spins are used as an ultra-sensitive probe for non-magnetic spin interactions of type δν∝ d{sub Xe}.E. With our experimental setup at the research center Juelich we are able to observe spin coherence times T{sub 2}{sup *} of several hours for both species. We report on first experimental results achieved within the MIXed-collaboration.

  18. Beta-delayed proton emitter $^{113}Xe$

    CERN Document Server

    Hagberg, E; Jonson, B; Jørgensen, B; Kugler, E; Mowinckel, T

    1973-01-01

    The ISOLDE facility at the CERN synchrocyclotron has been used for extending the series of beta -delayed proton emitters in xenon to masses lighter than those previously observed (/sup 115,117/Xe). Owing to the rapid decrease of the yields, experiments with solid-state counters were inconclusive, and instead a new and much more sensitive method based on nuclear emulsions was developed. The mass range 111-114 showed one new activity, /sup 113/Xe, with a half-life of 2.8+or-0.2 sec. From measurements of the track lengths for a total of 1130 protons from /sup 113/Xe it was possible to determine the energy spectrum. The results extend the systematics of beta -strength functions in the light xenon isotopes. (19 refs).

  19. Brain Imaging Using Hyperpolarized 129Xe Magnetic Resonance Imaging.

    Science.gov (United States)

    Chahal, Simrun; Prete, Braedan R J; Wade, Alanna; Hane, Francis T; Albert, Mitchell S

    2018-01-01

    Hyperpolarized (HP) 129 Xe magnetic resonance imaging (MRI) is a novel iteration of traditional MRI that relies on detecting the spins of 1 H. Since 129 Xe is a gaseous signal source, it can be used for lung imaging. Additionally, 129 Xe dissolves in the blood stream and can therefore be detectable in the brain parenchyma and vasculature. In this work, we provide detailed information on the protocols that we have developed to image 129 Xe within the brains of both rodents and human subjects. © 2018 Elsevier Inc. All rights reserved.

  20. Hyperpolarized 129Xe as an NMR probe for functional studies

    International Nuclear Information System (INIS)

    Wolber, J.

    2000-01-01

    The nuclear spin polarization of 129 Xe can be enhanced by several orders of magnitude using optical pumping techniques, resulting in a dramatic enhancement of the 129 Xe Nuclear Magnetic Resonance (NMR) signal. The 'hyperpolarized' gas can be used for Magnetic Resonance Imaging (MRI) of the void spaces of the lungs after introduction of the gas into the respiratory system. Furthermore, the high solubility of xenon in blood and lipids suggests the use of 129 Xe NMR for studying blood flow, permeability, perfusion and blood volume. Hyperpolarized 129 Xe MRI has the potential of combining the high sensitivity and functional information of radioactive tracer studies with the high spatial and temporal resolution of MRI. The spin-lattice relaxation time T 1 of 129 Xe in blood determines the loss of polarization during transit from the lungs to the tissue of interest. A difference in the relaxation times of xenon in oxygenated and deoxygenated blood could be used as a contrast mechanism in functional Magnetic Resonance Imaging (fMRI). In this thesis, the hyperpolarized 129 Xe T 1 in human blood is measured in vitro as a function of blood oxygenation, and the relevant relaxation mechanisms are discussed. A new and unexpected finding is that the hyperpolarized 129 Xe NMR spectrum in blood is highly sensitive to blood oxygenation. Therefore, hyperpolarized 129 Xe NMR provides a powerful means of measuring blood oxygenation quantitatively and non-invasively. The interaction of xenon with hemoglobin is responsible for an oxygen-dependent shift of the 129 Xe NMR resonance of xenon in red blood cells. Injection delivery of hyperpolarized 129 Xe in solution could be a more efficient method of administrating the gas for functional NMR studies. For this purpose, suitable biocompatible carrier media have been studied. In particular, the use of perfluorocarbon emulsions, which are already in use as blood substitutes, as delivery media for hyperpolarized 129 Xe has been investigates

  1. Laser Isotope Enrichment for Medical and Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Leonard Bond

    2006-07-01

    Laser Isotope Enrichment for Medical and Industrial Applications by Jeff Eerkens (University of Missouri), Jay Kunze (Idaho State University), and Leonard Bond (Idaho National Laboratory) The principal isotope enrichment business in the world is the enrichment of uranium for commercial power reactor fuels. However, there are a number of other needs for separated isotopes. Some examples are: 1) Pure isotopic targets for irradiation to produce medical radioisotopes. 2) Pure isotopes for semiconductors. 3) Low neutron capture isotopes for various uses in nuclear reactors. 4) Isotopes for industrial tracer/identification applications. Examples of interest to medicine are targets to produce radio-isotopes such as S-33, Mo-98, Mo-100, W-186, Sn-112; while for MRI diagnostics, the non-radioactive Xe-129 isotope is wanted. For super-semiconductor applications some desired industrial isotopes are Si-28, Ga-69, Ge-74, Se-80, Te-128, etc. An example of a low cross section isotope for use in reactors is Zn-68 as a corrosion inhibitor material in nuclear reactor primary systems. Neutron activation of Ar isotopes is of interest in industrial tracer and diagnostic applications (e.g. oil-logging). . In the past few years there has been a sufficient supply of isotopes in common demand, because of huge Russian stockpiles produced with old electromagnetic and centrifuge separators previously used for uranium enrichment. Production of specialized isotopes in the USA has been largely accomplished using old ”calutrons” (electromagnetic separators) at Oak Ridge National Laboratory. These methods of separating isotopes are rather energy inefficient. Use of lasers for isotope separation has been considered for many decades. None of the proposed methods have attained sufficient proof of principal status to be economically attractive to pursue commercially. Some of the authors have succeeded in separating sulfur isotopes using a rather new and different method, known as condensation

  2. Laser Isotope Enrichment for Medical and Industrial Applications

    International Nuclear Information System (INIS)

    Leonard Bond

    2006-01-01

    Laser Isotope Enrichment for Medical and Industrial Applications by Jeff Eerkens (University of Missouri), Jay Kunze (Idaho State University), and Leonard Bond (Idaho National Laboratory) The principal isotope enrichment business in the world is the enrichment of uranium for commercial power reactor fuels. However, there are a number of other needs for separated isotopes. Some examples are: (1) Pure isotopic targets for irradiation to produce medical radioisotopes. (2) Pure isotopes for semiconductors. (3) Low neutron capture isotopes for various uses in nuclear reactors. (4) Isotopes for industrial tracer/identification applications. Examples of interest to medicine are targets to produce radio-isotopes such as S-33, Mo-98, Mo-100, W-186, Sn-112; while for MRI diagnostics, the non-radioactive Xe-129 isotope is wanted. For super-semiconductor applications some desired industrial isotopes are Si-28, Ga-69, Ge-74, Se-80, Te-128, etc. An example of a low cross section isotope for use in reactors is Zn-68 as a corrosion inhibitor material in nuclear reactor primary systems. Neutron activation of Ar isotopes is of interest in industrial tracer and diagnostic applications (e.g. oil-logging). . In the past few years there has been a sufficient supply of isotopes in common demand, because of huge Russian stockpiles produced with old electromagnetic and centrifuge separators previously used for uranium enrichment. Production of specialized isotopes in the USA has been largely accomplished using old ''calutrons'' (electromagnetic separators) at Oak Ridge National Laboratory. These methods of separating isotopes are rather energy inefficient. Use of lasers for isotope separation has been considered for many decades. None of the proposed methods have attained sufficient proof of principal status to be economically attractive to pursue commercially. Some of the authors have succeeded in separating sulfur isotopes using a rather new and different method, known as condensation

  3. Continuing investigations for technology assessment of 99Mo production from LEU [low enriched uranium] targets

    International Nuclear Information System (INIS)

    Vandegrift, G.F.; Kwok, J.D.; Marshall, S.L.; Vissers, D.R.; Matos, J.E.

    1987-01-01

    Currently much of the world's supply of 99m Tc for medical purposes is produced from 99 Mo derived from the fissioning of high enriched uranium (HEU). This paper presents the results of our continuing studies on the effects of substituting low enriched uranium (LEU) for HEU in targets for the production of fission product 99 Mo. Improvements in the electrodeposition of thin films of uranium metal continue to increase the appeal for the substitution of LEU metal for HEU oxide films in cylindrical targets. The process is effective for targets fabricated from stainless steel or zircaloy. Included is a cost estimate for setting up the necessary equipment to electrodeposit uranium metal on cylindrical targets. Further investigations on the effect of LEU substitution on processing of these targets are also reported. Substitution of uranium silicides for the uranium-aluminium alloy or uranium aluminide dispersed fuel used in current target designs will allow the substitution of LEU for HEU in these targets with equivalent 99 Mo-yield per target and no change in target geometries. However, this substitution will require modifications in current processing steps due to 1) the insolubility of uranium silicides in alkaline solutions and 2) the presence of significant quantities of silicate in solution. Results to date suggest that substitution of LEU for HEU can be achieved. (Author)

  4. I-Xe dating of silicate and troilite from IAB iron meteorites

    International Nuclear Information System (INIS)

    Niemeyer, S.

    1979-01-01

    Silicate and troilite (FeS) from IAB irons were analyzed by the I-Xe technique. Four IAB silicate samples gave well-defined I-Xe ages [in millions of years relative to Bjurbole: - 3.7 +- 0.3 for Woodbine, -0.7 +- 0.6 for Mundrabilla, + 1.4 +- 0.7 for Copiapo, and +2.6 +- 0.6 for Landes. The ( 129 Xe/ 132 Xe)sub(trapped) ratios are consistent with previous values for chondrites, with the exception of Landes which has an extraordinary trapped ratio of 3.5 +- 0.2. Both analyses of silicate from Pitts gave anomalous I-Xe patterns. Troilite samples were also analyzed: Pitts troilite gave a complex I-Xe pattern, which suggests an age of +17 Myr; Mundrabilla troilite defined a good I-Xe correlation, which after correction for neutron capture on 128 Te gave an age of -10.8 +- 0.7 Myr. Thus, low-melting troilite predates high-melting silicate in Mundrabilla. Abundances of Ga, Ge, and Ni in metal from these meteorites are correlated with I-Xe ages of the silicate; meteorites with older silicates have greater Ni contents. No model easily accounts for this result as well as other properties of IAB irons; nevertheless, these results, taken at face value, favour a nebular formation model. The great age of troilite from Mundrabilla suggests that this troilite formed in a different nebular region from the silicate and metal, and was later mechanically mixed with these other phases. The correlation between the trace elements in the metal and the I-Xe ages of the silicate provides one of the first known instances in which another well-defined meteoritic property correlates with I-Xe ages. In addition, almost all the 129 Xe in Mundrabilla silicate (etched in acid) was correlated with 128 Xe. These two results further support the validity of the I-Xe dating method. (author)

  5. The novel immunotoxin HM1.24-ETA′ induces apoptosis in multiple myeloma cells

    International Nuclear Information System (INIS)

    Staudinger, M; Glorius, P; Burger, R; Kellner, C; Klausz, K; Günther, A; Repp, R; Klapper, W; Gramatzki, M; Peipp, M

    2014-01-01

    Despite new treatment modalities, the clinical outcome in a substantial number of patients with multiple myeloma (MM) has yet to be improved. Antibody-based targeted therapies for myeloma patients could make use of the HM1.24 antigen (CD317), a surface molecule overexpressed on malignant plasma cells and efficiently internalized. Here, a novel immunotoxin, HM1.24-ETA′, is described. HM1.24-ETA′ was generated by genetic fusion of a CD317-specific single-chain Fv (scFv) antibody and a truncated variant of Pseudomonas aeruginosa exotoxin A (ETA′). HM1.24-ETA′ inhibited growth of interleukin 6 (IL-6)-dependent and -independent myeloma cell lines. Half-maximal growth inhibition was observed at concentrations as low as 0.3 nM. Target cell killing occurred via induction of apoptosis and was unaffected in co-culture experiments with bone marrow stromal cells. HM1.24-ETA′ efficiently triggered apoptosis of freshly isolated/cryopreserved cells of patients with plasma cell leukemia and MM and was active in a preclinical severe combined immunodeficiency (SCID) mouse xenograft model. Importantly, HM1.24-ETA′ was not cytotoxic against CD317-positive cells from healthy tissue (monocytes, human umbilical vein endothelial cells). These results indicate that CD317 may represent a promising target structure for specific and efficient immunotoxin therapy for patients with plasma cell tumors

  6. Discharge characteristics of He-Ne-Xe gas mixture with varying Xe contents and at varying sustain electrode gap lengths in the plasma display panel

    International Nuclear Information System (INIS)

    Kwon, Ohyung; Whang, Ki-Woong; Bae, Hyun Sook

    2009-01-01

    The discharge characteristics of He-Ne-Xe gas mixture in the plasma display panel were investigated using a two-dimensional numerical simulation to understand the effects of adding He and varying the Xe contents in the gas mixture, and also varying sustain electrode gap. With 5% Xe content and 60 μm sustain electrode gap, decreased ionization led to the improvement of the vacuum ultraviolet (vuv) efficacy at increasing He mixing ratios. However, at 20% Xe content and 60 μm sustain electrode gap, increased electron heating improved the vuv efficacy until the He mixing ratio reached 0.7, but the efficacy decreased beyond the ratio of 0.7 due to the increased ionization of Xe atoms. At 5% Xe content and 200 μm sustain electrode gap, the vuv efficacy increased as a result of increased electron heating at the gap space at increasing He mixing ratios.

  7. Independent Yields of Kr and Xe Fragments at Photofission of Odd Nuclei ^{237}Np and ^{243}Am

    CERN Document Server

    Gangrsky, Yu P; Myshinskii, G V; Penionzhkevich, Yu E

    2004-01-01

    he independent yields of fragments Kr (A=89-93) and Xe (A=135-142) at photofission of odd nuclei 237Np and 243Am are presented. The experiments were performed using the bremsstrahlung of 25 MeV electrons on the microtron of FLNR, JINR. A technique was used that included the transportation of fragments which escaped from the target with the gas flow through a capillary and the condensation of inert gases in a cryostat at the temperature of liquid nitrogen. Kr and Xe isotopes were identified by the spectra of their daughter products. The mass number distributions of the independent yields of Kr and Xe isotopes and of the complementary fragments (Y and La at the photofission of ^{237}Np and Nb and Pr at the photofission of ^{243}Am) were obtained.

  8. Origin of anomalous Xe-H in nanodiamond stardust

    Energy Technology Data Exchange (ETDEWEB)

    Kratz, K. L. [Max-Planck-Institut für Chemie, Otto-Hahn-Institut, D-55128 Mainz, Germany and Fachbereich Chemie, Pharmazie und Geowissenschaften, Universitat Mainz, Mainz (United States); Farouqi, K. [Max-Planck-Institut für Chemie, Otto-Hahn-Institut, D-55128 Mainz, Germany and Zentrum für Astronomie der Universität Heidelberg, D-69120 Heidelberg (Germany); Hallmann, O. [Max-Planck-Institut für Chemie, Otto-Hahn-Institut, D-55128 Mainz (Germany); Pfeiffer, B. [II. Physikalisches Institut, Univ. Giessen, D-35392 Giessen (Germany); Ott, U. [Max-Planck-Institut für Chemie, Otto-Hahn-Institut, D-55128 Mainz (Germany); Univ. of West Hungary, H-9700 Szombathely (Hungary)

    2014-05-09

    Still today, the nucleosynthesis origin of Xe-H in presolar nanodiamonds is far from understood. Historically possible explanations were proposed by a secondary “neutron-burst” process occurring in the He- or C/O-shells of a type-II supernova (SN-II), which are, however, not fully convincing in terms of modern nucleosynthesis conditions. Therefore, we have investigated Xe isotopic abundance features that may be diagnostic for different versions of a classical, primary r-process in high-entropy-wind (HEW) ejecta of core-collapse SN-II. We report here on parameter tests for non-standard r-process variants, by varying electron abundances (Y{sub e}), ranges of entropies (S) and expansion velocities (V{sub exp}) with their correlated neutron-freezeout times (τ(freeze)) and temperatures (T{sub 9}(freeze)). From this study, we conclude that a best fi to the measured Xe-H abundance ratios {sup i}Xe/{sup 136}Xe can be obtained with the high-S “main” component of a “cold” r-process variant.

  9. Development of industrial-scale fission {sup 99}Mo production process using low enriched uranium target

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Kon; Lee, Jun Sig [Radioisotope Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Beyer, Gerd J. [Grunicke Strasse 15, Leipzig (Germany)

    2016-06-15

    Molybdenum-99 ({sup 99}Mo) is the most important isotope because its daughter isotope, technetium-99m ({sup 99}mTc), has been the most widely used medical radioisotope for more than 50 years, accounting for > 80% of total nuclear diagnostics worldwide. In this review, radiochemical routes for the production of {sup 99}Mo, and the aspects for selecting a suitable process strategy are discussed from the historical viewpoint of {sup 99}Mo technology developments. Most of the industrial-scale {sup 99}Mo processes have been based on the fission of {sup 235}U. Recently, important issues have been raised for the conversion of fission {sup 99}Mo targets from highly enriched uranium to low enriched uranium (LEU). The development of new LEU targets with higher density was requested to compensate for the loss of {sup 99}Mo yield, caused by a significant reduction of {sup 235}U enrichment, from the conversion. As the dramatic increment of intermediate level liquid waste is also expected from the conversion, an effective strategy to reduce the waste generation from the fission {sup 99}Mo production is required. The mitigation of radioxenon emission from medical radioisotope production facilities is discussed in relation with the monitoring of nuclear explosions and comprehensive nuclear test ban. Lastly, the {sup 99}Mo production process paired with the Korea Atomic Energy Research Institute's own LEU target is proposed as one of the most suitable processes for the LEU target.

  10. Half-life of Xe120

    Science.gov (United States)

    Phillips, A. A.; Andreoiu, C.; Ball, G. C.; Bandyopadhyay, D.; Behr, J. A.; Chupp, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hayden, M. E.; Hyland, B.; Nuss-Warren, S. R.; Pearson, M. R.; Schumaker, M. A.; Smith, M. B.; Svensson, C. E.; Tardiff, E. R.; Valiente-Dobón, J. J.; Warner, T.

    2006-08-01

    We have measured the half-life of Xe120 using a high-purity germanium (HPGe) detector to monitor the 176, 178, and 762 keV γ rays from Xe120 β+ decay. The result, 46±0.6 min, differs significantly from the value 40±1 min reported by Andersson [Ark. Fys. 28, 37 (1964)]. We have also measured the half-lives of Cs120 and I120 to be 60±0.7 s and 82.1±0.6 min, respectively, both of which are consistent with previous measurements.

  11. Measurement of the azimuthal anisotropy of charged particle production in Xe+Xe collisions at $\\sqrt{s_{\\mathrm{NN}}}$=5.44~TeV with the ATLAS detector

    CERN Document Server

    The ATLAS collaboration

    2018-01-01

    This note describes the measurement of flow harmonics $v_2$--$v_5$ in Xe+Xe collisions at $\\sqrt{s_{\\mathrm{NN}}}$=5.44~TeV performed using the ATLAS detector at the LHC. The measurements are performed using multi-particle correlations involving 2, 4 and 6 particles and the Scalar Product technique. Measurements of the centrality and $p_{\\mathrm{T}}$ dependence of the $v_n$ are presented. Comparisons of the measured $v_n$ to previous measurements for Pb+Pb collisions at $\\sqrt{s_{\\mathrm{NN}}}$=5.02~TeV are also presented. The Xe+Xe $v_n$ are observed to be larger than the Pb+Pb $v_n$ for $n$=2,3 and $4$ in the most central events, but with decreasing centrality or increasing harmonic order $n$, the Xe+Xe $v_n$ become smaller than the Pb+Pb $v_n$. The Xe+Xe and Pb+Pb comparisons are also shown as a function of the mean number of participants $\\langle N_\\text{part} \\rangle$, and the 4-particle cumulants for higher-order harmonics -- $v_3\\{4\\}$ and $v_4\\{4\\}$ -- are found to scale better with $\\langle N_\\text{p...

  12. EUV emission from Kr and Xe capillary discharge plasmas

    International Nuclear Information System (INIS)

    Juschkin, L.; Ellwi, S.; Kunze, H-J.; Chuvatin, A.; Zakharov, S.V.

    2002-01-01

    Kr and Xe plasmas are very intensive emitters in the spectral range of 100-150 A, which is relevant for a number of applications (for example microlithography). We present investigations of the extreme utraviolet (EUV) emission from a slow capillary discharge with Kr and Xe fillings. The emission of Kr ions (Kr VIII to Kr XI) within the range of 70-150 A consists of three bands of lines of about 10 A width with maxima at 116, 103 and 86 A. Xe emission bands of about 15 A width have their maxima at 136 and 115 A (Xe IX to Xe XII). The radiation duration in this spectral range is ∼150 ns for both elements. At the optimum conditions, the Kr emission at 103 A is 2-3 times more intense than the Xe emission at 136 A. The measured spectral energy of Kr radiation is about 0.1 J sr -1 A -1 . Experimental results are compared with numerical modellings of the dynamics and emission of the capillary discharge plasma, which enables the determination of plasma parameters and the future use of the codes as additional instruments for plasma diagnostics. (author)

  13. C30F12.4 influences oogenesis, fat metabolism, and lifespan in C. elegans

    Directory of Open Access Journals (Sweden)

    Lu Wang

    2016-09-01

    Full Text Available ABSTRACT Reproduction, fat metabolism, and longevity are intertwined regulatory axes; recent studies in C. elegans have provided evidence that these processes are directly coupled. However, the mechanisms by which they are coupled and the reproductive signals modulating fat metabolism and lifespan are poorly understood. Here, we find that an oogenesis-enriched gene, c30f12.4, is specifically expressed and located in germ cells and early embryos; when the gene is knocked out, oogenesis is disrupted and brood size is decreased. In addition to the reproductive phenotype, we find that the loss of c30f12.4 alters fat metabolism, resulting in decreased fat storage and smaller lipid droplets. Meanwhile, c30f12.4 mutant worms display a shortened lifespan. Our results highlight an important role for c30f12.4 in regulating reproduction, fat homeostasis, and aging in C. elegans, which helps us to better understand the relationship between these processes.

  14. Xe isotope detection and discrimination using beta spectroscopy with coincident gamma spectroscopy

    Science.gov (United States)

    Reeder, P. L.; Bowyer, T. W.

    1998-02-01

    Beta spectroscopic techniques show promise of significant improvements for a beta-gamma coincidence counter that is part of a system for analyzing Xe automatically separated from air. The previously developed counting system for 131mXe, 133mXe, 133gXe, and 135gXe can be enhanced to give additional discrimination between these Xe isotopes by using the plastic scintillation sample cell as a beta spectrometer to resolve the conversion electron peaks. The automated system will be a key factor in monitoring the Comprehensive Test Ban Treaty.

  15. Xe isotopic abundances in enstatite meteorites and relations to other planetary reservoirs

    International Nuclear Information System (INIS)

    Lee, Jee-Yon; Marti, Kurt; Wacker, John F.

    2009-01-01

    This paper describes the interpretation of xenon that was measured in the Abee meteorite. Reported Xe isotopic abundances in enstatite chondrites (EC's) show some variability, and this makes comparisons to other solar system reservoirs rather difficult. In contrast, we find uniform Xe isotopic abundances in the EC chondrite Abee for a variety of clasts, except for 128 Xe and 129 Xe, the isotopes affected by neutron capture in I and by extinct 129 I. We report averages for the studied clasts which are consistent within error limits with OC-Xe and with the Q-Xe signature. On the other hand, the elemental abundance ratios Ar/Xe are variable between clasts. A strongly reducing environment which is indicated for enstatite meteorites was generally assumed to be consistent with conditions existing in the early inner solar system. Xe isotopic abundances in SNC meteorites from Mars and also those in some terrestrial wells show that distinct isotopic reservoirs coexisted on the same planets. In particular, the Xe isotopic signatures in terrestrial well gases show the presence of a minor distinct component in two of the reported four well gases. These authors suggested that the extra component represents solar Xe, but we show that also a meteoritic xenon reservoir of the Abee-Xe structure is an option. The reported Xe data in Ar-rich (subsolar) EC's show isotopic abundances slightly lighter than those in Abee-Xe, but the relative abundances of Ar, Kr, and Xe indicate only a minor component of elementally unfractionated solar Xe. The elemental ratios suggest rather a different origin for these gases: the loading of solar particles into grain surfaces during exposure at elevated temperatures during accretion of matter in the inner solar system. A model of this type was suggested for the accretion of gases now observed in the atmosphere on Venus. We note that disks of crystalline silicates (including enstatite and olivine) have been observed in T Tauri stars during their early

  16. Attenuation curves in concrete of neutrons from 100 to 400 MeV per nucleon He, C, Ne, Ar, Fe and Xe ions on various targets

    Energy Technology Data Exchange (ETDEWEB)

    Agosteo, S.; Nakamura, T.; Silari, M. E-mail: marco.silari@cern.ch; Zajacova, Z

    2004-04-01

    Data on transmission of neutrons in concrete generated by heavy ions of intermediate energies (of typically up to 1 GeV per nucleon) are of interest for shielding design of accelerators for use in both the research and in the medical field. The energy distributions of neutrons produced by ions of different species (from He to Xe) striking various targets at energies from 100 to 800 MeV per nucleon were recently measured by Kurosawa et al. in the angular range 0-90 deg. . These spectra were used as input data for Monte Carlo simulations to determine source terms and attenuation lengths in ordinary concrete. The present paper presents calculations for 100 MeV/u helium ions on a Cu target, 100 MeV/u carbon ions on C, Al, Cu and Pb, 100 MeV/u neon ions on Cu and Pb, 400 MeV/u carbon ions on C, Al, Cu and Pb, 400 MeV/u neon ions on Cu, 400 MeV/u Ar ions on Cu, 400 MeV/u Fe ions on Cu and 400 MeV/u Xe ions on Cu. The results include the contributions of all secondaries. Some of the resulting attenuation curves are best fitted by a double-exponential function rather than the usual single-exponential. The effect of various approximations introduced in the simulations is discussed. A comparison is made with shielding data for protons scaled with the ion mass number. A comparison is also made with a simple analytical model in use at GANIL.

  17. MiR-124 Inhibits Growth and Enhances Radiation-Induced Apoptosis in Non-Small Cell Lung Cancer by Inhibiting STAT3

    Directory of Open Access Journals (Sweden)

    Mengjie Wang

    2017-12-01

    Full Text Available Background/Aims: A growing body of evidence indicates that the abnormal expression of microRNAs (miRNAs play an important role in sensitizing the cellular response to ionizing radiation (IR. The aim of this study was to investigate whether the expression of miR-124 correlated with radiosensitivity in the context of non-small-cell lung carcinoma (NSCLC. Methods: Quantitative reverse transcription polymerase chain reaction (RT-PCR was used to quantify miR-124 expression in NSCLC tissues and cell lines. The role of miR-124 in NSCLC proliferation and radiosensitivity was analyzed using CCK-8 and flow cytometry apoptosis assays. Luciferase activity assays, RT-PCR, and Western blot assays were performed to confirm the target gene of miR-124. Results: In this study, we found that miR-124 was downregulated both in clinical NSCLC samples and in cell lines. miR-124 inhibited the proliferation of NSCLC cells and enhanced the apoptosis of NSCLC cells exposed to ionizing radiation. We identified signal transducer and activator of transcription 3 (STAT3 as a direct target of miR-124 by using target prediction algorithms and luciferase assays. Overexpression of STAT3 in A549 cell lines restored the enhanced radiosensitivity induced by miR-124. Conclusion: Taking these observations into consideration, we illustrated that miR-124 is a potential target for enhancing the radiosensitivity of NSCLC cells by targeting STAT3.

  18. The Development of Target-Specific Pose Filter Ensembles To Boost Ligand Enrichment for Structure-Based Virtual Screening.

    Science.gov (United States)

    Xia, Jie; Hsieh, Jui-Hua; Hu, Huabin; Wu, Song; Wang, Xiang Simon

    2017-06-26

    Structure-based virtual screening (SBVS) has become an indispensable technique for hit identification at the early stage of drug discovery. However, the accuracy of current scoring functions is not high enough to confer success to every target and thus remains to be improved. Previously, we had developed binary pose filters (PFs) using knowledge derived from the protein-ligand interface of a single X-ray structure of a specific target. This novel approach had been validated as an effective way to improve ligand enrichment. Continuing from it, in the present work we attempted to incorporate knowledge collected from diverse protein-ligand interfaces of multiple crystal structures of the same target to build PF ensembles (PFEs). Toward this end, we first constructed a comprehensive data set to meet the requirements of ensemble modeling and validation. This set contains 10 diverse targets, 118 well-prepared X-ray structures of protein-ligand complexes, and large benchmarking actives/decoys sets. Notably, we designed a unique workflow of two-layer classifiers based on the concept of ensemble learning and applied it to the construction of PFEs for all of the targets. Through extensive benchmarking studies, we demonstrated that (1) coupling PFE with Chemgauss4 significantly improves the early enrichment of Chemgauss4 itself and (2) PFEs show greater consistency in boosting early enrichment and larger overall enrichment than our prior PFs. In addition, we analyzed the pairwise topological similarities among cognate ligands used to construct PFEs and found that it is the higher chemical diversity of the cognate ligands that leads to the improved performance of PFEs. Taken together, the results so far prove that the incorporation of knowledge from diverse protein-ligand interfaces by ensemble modeling is able to enhance the screening competence of SBVS scoring functions.

  19. XeCl Excimer Laser with Three- and Four-Component Mixture of Active Gases

    International Nuclear Information System (INIS)

    Iwanejko, L.; Pokora, L.

    1998-01-01

    Selected results of investigations of a XeCl excimer laser employing a new type (four-component)of mixture of gases, He-Kr:Xe-HCl, are presented. The mixture includes, instead of Xe, a mixture of not-separated Kr and Xe gases, much less expensive than pure xenon. A comparison of durations and energies of pulses generated in the XeCl excimer laser using three- or four-component gaseous active medium (He-Xe-HCl or He-Kr:Xe-HCl) is made. The investigations have been carried out with the use of a laser system with UV preionization and self sustained pumping discharge. (author)

  20. Variable energy positron beam study of Xe-implanted uranium oxide

    International Nuclear Information System (INIS)

    Djourelov, Nikolay; Marchand, Benoît; Marinov, Hristo; Moncoffre, Nathalie; Pipon, Yves; Nédélec, Patrick; Toulhoat, Nelly; Sillou, Daniel

    2013-01-01

    Doppler broadening of annihilation gamma-line combined with a slow positron beam was used to measure the momentum density distribution of annihilating pair in a set of sintered UO 2 samples. The influence of surface polishing, of implantation with 800-keV 136 Xe 2+ at fluences of 1 × 10 15 and 1 × 10 16 Xe cm −2 , and of annealing were studied by following the changes of the momentum distribution shape by means of S and W parameters. The program used for this purpose was VEPFIT. At the two fluences in the stoichiometric as-implanted UO 2 , formation of Xe bubbles was not detected. The post-implantation annealing and over-stoichiometry in the as-implanted sample caused Xe precipitation and formation of Xe bubbles.

  1. Continuing investigations for technology assessment of 99Mo production from LEU [low enriched Uranium] targets

    International Nuclear Information System (INIS)

    Vandergrift, G.F.; Kwok, J.D.; Marshall, S.L.; Vissers, D.R.; Matos, J.E.

    1987-01-01

    Currently much of the world's supply of /sup 99m/Tc for medical purposes is produced from 99 Mo derived from the fissioning of high enriched uranium (HEU). The need for /sup 99m/Tc is continuing to grow, especially in developing countries, where needs and national priorities call for internal production of 99 Mo. This paper presents the results of our continuing studies on the effects of substituting low enriched Uranium (LEU) for HEU in targets for the production of fission product 99 Mo. Improvements in the electrodeposition of thin films of uranium metal are reported. These improvements continue to increase the appeal for the substitution of LEU metal for HEU oxide films in cylindrical targets. The process is effective for targets fabricated from stainless steel or hastaloy. A cost estimate for setting up the necessary equipment to electrodeposit uranium metal on cylindrical targets is reported. Further investigations on the effect of LEU substitution on processing of these targets are also reported. Substitution of uranium silicides for the uranium-aluminum alloy or uranium aluminide dispersed fuel used in other current target designs will allow the substitution of LEU for HEU in these targets with equivalent 99 Mo-yield per target and no change in target geometries. However, this substitution will require modifications in current processing steps due to (1) the insolubility of uranium silicides in alkaline solutions and (2) the presence of significant quantities of silicate in solution. Results to date suggest that both concerns can be handled and that substitution of LEU for HEU can be achieved

  2. Evaluation of reactivity and Xe behavior during daily load following operation

    International Nuclear Information System (INIS)

    Sakamoto, Yasunori; Araki, Tsuneyasu; Yamamoto, Fumiaki

    1992-01-01

    A boiling water reactor (BWR) has an excellent load following capability provided by a core flow control, which is used for changing a reactor power level and for compensating the subsequent Xe concentration change. The core characteristics during load following operations are investigated in detail, using our reactor core simulator. Comparisons of changes of the Doppler reactivity, the void reactivity and the Xe reactivity during transients are performed. Also the features of Xe transient during load following operations are shown. It has been shown that the core flow change required to compensate the Xe reactivity change produces much greater change of the void reactivity than that required for power level changes, and that the resulting local power change in the lower part of the core is greater than that in the upper part, because the Xe concentration change in the lower part is hardly compensated by the core flow control. Also the effects of power level changes, cycle patterns, and initial concentration of Xe and I on the Xe transient behavior have been investigated. (author)

  3. Using targeted enrichment of nuclear genes to increase phylogenetic resolution in the neotropical rain forest genus Inga (Leguminosae: Mimosoideae

    Directory of Open Access Journals (Sweden)

    James A Nicholls

    2015-09-01

    Full Text Available Evolutionary radiations are prominent and pervasive across many plant lineages in diverse geographical and ecological settings; in neotropical rainforests there is growing evidence suggesting that a significant fraction of species richness is the result of recent radiations. Understanding the evolutionary trajectories and mechanisms underlying these radiations demands much greater phylogenetic resolution than is currently available for these groups. The neotropical tree genus Inga (Leguminosae is a good example, with ~300 extant species and a crown age of 2-10 MY, yet over 6kb of plastid and nuclear DNA sequence data gives only poor phylogenetic resolution among species. Here we explore the use of larger-scale nuclear gene data obtained though targeted enrichment to increase phylogenetic resolution within Inga. Transcriptome data from three Inga species were used to select 264 nuclear loci for targeted enrichment and sequencing. Following quality control to remove probable paralogs from these sequence data, the final dataset comprised 259,313 bases from 194 loci for 24 accessions representing 22 Inga species and an outgroup (Zygia. Bayesian phylogenies reconstructed using either all loci concatenated or a subset of 60 loci in a gene-tree/species-tree approach yielded highly resolved phylogenies. We used coalescent approaches to show that the same targeted enrichment data also have significant power to discriminate among alternative within-species population histories in the widespread species I. umbellifera. In either application, targeted enrichment simplifies the informatics challenge of identifying orthologous loci associated with de novo genome sequencing. We conclude that targeted enrichment provides the large volumes of phylogenetically-informative sequence data required to resolve relationships within recent plant species radiations, both at the species level and for within-species phylogeographic studies.

  4. Symmetry structure in neutron deficient xenon nuclei

    International Nuclear Information System (INIS)

    Govil, I. M.

    1998-01-01

    The paper describes the measurements of the lifetimes of the excited states in the ground state band of the Neutron deficient Xe nuclei ( 122,124 Xe) by recoil Distance Method (RDM). The lifetimes of the 2 + state in 122 Xe agrees with the RDM measurements but for 124 Xe it does not agree the RDM measurements but agrees with the earlier Coulomb-excitation experiment. The experimental results are compared with the existing theories to understand the changes in the symmetry structure of the Xe-nuclei as the Neutron number decreases from N=76( 130 Xe) to N=64( 118 Xe)

  5. Symmetry structure in neutron deficient xenon nuclei

    Science.gov (United States)

    Govil, I. M.

    1998-12-01

    The paper describes the measurements of the lifetimes of the excited states in the ground state band of the Neutron deficient Xe nuclei (122,124Xe) by recoil Distance Method (RDM). The lifetimes of the 2+ state in 122Xe agrees with the RDM measurements but for 124Xe it does not agree the RDM measurements but agrees with the earlier Coulomb-excitation experiment. The experimental results are compared with the existing theories to understand the changes in the symmetry structure of the Xe-nuclei as the Neutron number decreases from N=76(130Xe) to N=64(118Xe).

  6. microRNA-124 negatively regulates TLR signaling in alveolar macrophages in response to mycobacterial infection.

    Science.gov (United States)

    Ma, Chunyan; Li, Yong; Li, Min; Deng, Guangcun; Wu, Xiaoling; Zeng, Jin; Hao, Xiujing; Wang, Xiaoping; Liu, Jing; Cho, William C S; Liu, Xiaoming; Wang, Yujiong

    2014-11-01

    The emerging roles of microRNAs (miRNAs) in regulating immune responses have attracted increasing attention in recent years; and the alveolar macrophages (AMs) are the main targets of mycobacterial infection, which play a pivotal role in the pathogenesis of Mycobacterium tuberculosis infection. However, the immunoregulatory role of miRNAs in AMs has not been fully demonstrated. In this study, we find that miR-124 is up-regulated in the peripheral leukocytes of patients with pulmonary tuberculosis; furthermore, the expression miR-124 can be induced upon Mycobacterium bovis Bacillus Calmette-Guerin (BCG) infection in both RAW264.7 AM cells in vitro and murine AMs in vivo. Mechanistically, miR-124 is able to modulate toll-like receptor (TLR) signaling activity in RAW264.7 cells in response to BCG infection. In this regard, multiple components of TLR signaling cascade, including the TLR6, myeloid differentiation factor 88 (MyD88), TNFR-associated factor 6 and tumor necrosis factor-α are directly targeted by miR-124. In addition, both overexpression of TLR signaling adaptor MyD88 and BCG infection are able to augment miR-124 transcription, while MyD88 expression silenced by small interfering RNA dramatically suppresses miR-124 expression in AMs in vitro. Moreover, the abundance of miR-124 transcript in murine AMs of MyD88 deficient mice is significantly less than that of their wild-type or heterozygous littermates; and the BCG infection fails to induce miR-124 expression in the lung of MyD88 deficient mouse. These results indicate a negative regulatory role of miR-124 in fine-tuning inflammatory response in AMs upon mycobacterial infection, in part through a mechanism by directly targeting TLR signaling. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. I-Xe dating of silicate and troilite from IAB iron meteorites

    International Nuclear Information System (INIS)

    Niemeyer, S.

    1978-01-01

    The IAB iron meteorites may be related to the chondrites; siderophile elements in the metal matrix have chondritic abundances, and the abundant silicate inclusions are chondritic both in mineralogy and in chemical composition. Silicate and troilite (FeS) and IAB irons were analyzed by the I-Xe technique. Four IAB silicate samples gave well-defined I-Xe ages [in millions of years relative to Bjurboele; the monitor error (+-2.5 m.y.) is not included]: -3.7 +- 0.3 for Woodbine, -0.7 +- 0.6 for Mundrabilla, +1.4 +- 0.7 for Copiapo, and +2.6 +- 0.6 for Landes. The ( 129 Xe/ 132 Xe)/sub trapped/ ratios are consistent with previous values for chondrites, with the exception of Landes which has an extraordinary trapped ratio of 3.5 +- 0.2. Both analyses of silicate from Pitts gave anomalous I-Xe patterns: intermediate-temperature points defined good correlations but higher-temperature (greater than or equal to 1400 0 C) points lay above (extra 129 Xe) these lines. The two correlations have different slopes, so it cannot be assigned a definite I-Xe age to Pitts silicate. Troilite samples from Mundrabilla and Pitts were also analyzed: Pitts troilite gave a complex I-Xe pattern, which suggests an age of +17 m.y.; Mundrabilla troilite defined a good I-Xe correlation, which after correction for neutron capture on 128 Te an age of -10.8 +- 0.7 m.y. Thus, surprisingly, low-melting troilite substantially predates high-melting silicate in Mundrabilla. Abundances of Ga, Ge, and Ni in metal from these meteorites are correlated with I-Xe ages of the silicate (referred to henceforth as the metal-silicate correlation). After exploring possible relationships between the I-Xe ages and other properties of the IAB group, it was concluded that the metal-silicate correlation, the old Mundrabilla troilite, and other results favor a nebular formation model (e.g. Wasson, 1970a)

  8. Xe/Kr Selectivity Measurements using AgZ-PAN at Various Temperatures

    International Nuclear Information System (INIS)

    Garn, Troy Gerry; Greenhalgh, Mitchell Randy; Watson, Tony Leroy

    2015-01-01

    In preparation for planned FY-15 Xe/Kr multi-column testing, a series of experiments were performed to determine the selectivity of Xe over Kr using the silver converted mordenite-polyacrylonitrile (AgZ-PAN) sorbent. Results from these experiments will be used for parameter selection guidelines to define test conditions for Kr gas capture purity evaluations later this year. The currently configured experimental test bed was modified by installing a new cooling apparatus to permit future multi-column testing with independent column temperature control. The modified test bed will allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents. Selectivity experiments were run at temperatures of 295, 250 and 220 K. Two feed gas compositions of 1000 ppmv Xe, 150 ppmv Kr in either a He or an air balance were used. AgZ-PAN sorbent selectivity was calculated using Xe and Kr capacity determinations. AgZ-PAN sorbent selectivities for Xe over Kr of 72 were calculated at room temperature (295 K) using the feed gas with a He balance and 34 using the feed gas with an air balance. As the test temperatures were decreased the selectivity of Xe over Kr also decreased due to an increase in both Xe and Kr capacities. At 220 K, the sorbent selectivities for Xe over Kr were 22 using the feed gas with a He balance and 28 using the feed gas with an air balance. The selectivity results indicate that AgZ-PAN used in the first column of a multi-column configuration will provide adequate partitioning of Xe from Kr in the tested temperature range to produce a more pure Kr end product for collection.

  9. Effect of Xe ion (167 MeV) irradiation on polycrystalline SiC implanted with Kr and Xe at room temperature

    International Nuclear Information System (INIS)

    Hlatshwayo, T T; Kuhudzai, R J; Njoroge, E G; Malherbe, J B; O’Connell, J H; Skuratov, V A; Msimanga, M

    2015-01-01

    The effect of swift heavy ion (Xe 167 MeV) irradiation on polycrystalline SiC individually implanted with 360 keV Kr and Xe ions at room temperature to fluences of 2  ×  10 16 cm −2 and 1  ×  10 16 cm −2 respectively, was investigated using transmission electron microscopy (TEM), Raman spectroscopy and Rutherford backscattering spectrometry (RBS). Implanted specimens were each irradiated with 167 MeV Xe +26 ions to a fluence of 8.3  ×  10 14 cm −2 at room temperature. It was observed that implantation of 360 keV Kr and Xe ions individually at room temperature amorphized the SiC from the surface up to a depth of 186 and 219 nm respectively. Swift heavy ion (SHI) irradiation reduced the amorphous layer by about 27 nm and 30 nm for the Kr and Xe samples respectively. Interestingly, the reduction in the amorphous layer was accompanied by the appearance of randomly oriented nanocrystals in the former amorphous layers after SHI irradiation in both samples. Previously, no similar nanocrystals were observed after SHI irradiations at electron stopping powers of 33 keV nm −1 and 20 keV nm −1 to fluences below 10 14 cm −2 . Therefore, our results suggest a fluence threshold for the formation of nanocrystals in the initial amorphous SiC after SHI irradiation. Raman results also indicated some annealing of radiation damage after swift heavy ion irradiation and the subsequent formation of small SiC crystals in the amorphous layers. No diffusion of implanted Kr and Xe was observed after swift heavy ion irradiation. (paper)

  10. Shock disturbance of the I-Xe system

    International Nuclear Information System (INIS)

    Caffee, M.W.; Hohenberg, C.M.; Podosek, F.A.; Swindle, T.D.

    1982-01-01

    Three separate samples of the meteorite Bjurbole were artificially shocked at pressures of 70 kb, 200 kb, and 400 kb. Analysis of xenon released in stepwise heating shows that the I-Xe system of the 400 kb sample is substantially altered by the shock loading, and it is no longer possible to infer an age or trapped xenon composition for that sample. The 200-kb and 70-kb samples display isotopic structures progressively less altered demonstrating the gradations in shock disturbance likely to be found in natural systems. Interpretations of the I-Xe and Ar-40-Ar-39 systems for several naturally shocked meteorites are also presented. New data for Arapahoe do not confirm the previously reported age and trapped xenon composition, demonstrating instead that its I-Xe structure has been strongly disturbed by shock

  11. Calculation of Ion Charge State Distributions After Inner-Shell Ionization in Xe Atom

    International Nuclear Information System (INIS)

    Mohammedein, A.M.; Ghoneim, A.A.; Kandil, M.K.; Kadad, I.M.

    2009-01-01

    The vacancy cascades following initial inner-shell vacancies in single and multi-ionized atoms often lead to highly charged residual ions. The inner-shell vacancy produced by ionization processes may decay by either a radiative or non-radiative transition. In addition to the vacancy filling processes, there is an electron shake off process due to the change of core potential of the atom. In the calculation of vacancy cascades, the radiative (x-ray) and non-radiative (Auger and Coster-Kronig) branching ratios give valuable information on the de-excitation dynamics of an atom with inner-shell vacancy. The production of multi-charged ions yield by the Auger cascades following inner shell ionization of an atom has been studied both experimentally and theoretically. Multi-charged Xe ions following de-excitation of K, L 1 , L 2,3 , M 1 , M 2,3 and M 4,5 subshell vacancies are calculated using Monte-Carlo algorithm to simulate the vacancy cascade development. Fluorescence yield (radiative) and Auger, Coster- Kronig yield (non- radiative) are evaluated. The decay of K hole state through radiative transitions is found to be more probable than non-radiative transitions in the first step of de-excitation. On the other hand, the decay of L, M vacancies through non-radiative transitions are more probable. The K shell ionization in Xe atom mainly yields Xe 7+ , Xe 8+ , Xe 9+ and Xe 1 0 + ions, and the charged X 8+ ions are the highest. The main product from the L 1 shell ionization is found to be Xe 8+ , Xe 9+ ions, while the charged Xe 8+ ions predominate at L 2,3 hole states. The charged Xe 6+ , Xe 7+ and Xe 8+ ions mainly yield from 3s 1/2 and 3p 1/2 , 3/2 ionization, while Xe in 3d 3/2 , 5/2 hole states mainly turns into Xe 4+ and Xe 5+ ions. The present results are found to agree well with the experimental data. (author)

  12. In-situ observation of atomic self-organization processes in Xe nanocrystals embedded in Al

    International Nuclear Information System (INIS)

    Mitsuishi, K.; Song, M.; Furuya, K.; Birtcher, R. C.; Allen, C. W.; Donnelly, S. E.

    1998-01-01

    Self-organization processes in Xe nanocrystals embedded in Al are observed with in-situ high-resolution electron microscopy. Under electron irradiation, stacking fault type defects are produced in Xe nanocrystals. The defects recover in a layer by layer manner. Detailed analysis of the video reveals that the displacement of Xe atoms in the stacking fault was rather small for the Xe atoms at boundary between Xe and Al, suggesting the possibility of the stacking fault in Xe precipitate originating inside of precipitate, not at the Al/Xe interface

  13. Excess 129Xe in terrestrial samples: A non-primordial hypothesis

    International Nuclear Information System (INIS)

    Caffee, M.W.; Hudson, G.B.

    1987-03-01

    Excesses of 129 Xe relative to the isotopic composition in air are observed in some terrestrial samples. Traditionally these 129 Xe excesses have been thought to be related to 129 I that was present in abundance in the early solar system. We propose an alternative hypothesis to explain terrestrial 129 Xe excesses based on the production of 129 I from the spontaneous fission of 238 U

  14. Luminescent Characteristics of a Pulsed Discharge Plasma in Xe-KBr Mixture

    Science.gov (United States)

    Heneral, A. A.; Zhmenyak, Y. V.

    2018-03-01

    A mixture of xenon with a nontoxic halogen carrier Xe-KBr is used to create a plasma radiation source at the 282-nm transition of the XeBr* molecule excited by a high-voltage pulsed-periodic discharge. The luminescence spectra of the plasma of a longitudinal pulsed-periodic discharge in the Xe-KBr mixture at low pressures are studied experimentally. The most intense UV bands of exciplex XeBr* molecules are recorded in the spectral range of 250-350 nm. The spectral, temporal, and energetic characteristics of the radiation source are presented, as well as the dependence of the XeBr* exciplex molecule formation efficiency on the discharge excitation conditions. The optimal conditions for the excitation of UV radiation in the pulsed-periodic discharge plasma are determined.

  15. Xe isotopic constraints on cycling of deep Earth volatiles

    Science.gov (United States)

    Parai, R.; Mukhopadhyay, S.

    2017-12-01

    The modern deep Earth volatile budget reflects primordial volatiles delivered during accretion, radiogenic ingrowth of volatile species (e.g., 40Ar produced by 40K decay), outgassing in association with mantle processing, and regassing via subduction. The noble gases are unique volatile tracers in that they are chemically inert, but are thought to be trapped within hydrous alteration phases in downwelling lithologies. Noble gases thus provide a tracer of volatile transport between the deep Earth and surface reservoirs. Constraints on the fluxes of noble gases between deep Earth and surface reservoirs over time can accordingly be used to provide insight into temperature conditions at subduction zones, limits on volatile cycling, and the evolving distribution of major volatile species in terrestrial reservoirs over time. Xe isotope systematics in mantle-derived rocks show that 80-90% of the mantle Xe budget is derived from recycling of atmospheric Xe, indicating that atmospheric Xe is retained in subducting slabs beyond depths of magma generation in subduction zones over Earth history. We present an integrated model of Xe cycling between the mantle and atmosphere in association with mantle processing over Earth history. We test a wide variety of outgassing and regassing rates and take the evolution of the atmospheric Xe isotopic composition [e.g., 1] into account. Models in which the deep Earth transitions from a net outgassing to net regassing regime best satisfy Xe isotopic constraints from mantle-derived rocks [2-6]. [1] Avice et al., 2017; Nature Communications, 8; [2] Mukhopadhyay, 2012, Nature 486, 101-104; [3] Parai et al., 2012, EPSL 359-360, 227-239; [4] Parai and Mukhopadhay, 2015, G-cubed 16, 719-735; [5] Peto et al., 2013, EPSL 369-370, 13-23; [6] Tucker et al., 2012, EPSL 355-356, 244-254.

  16. Closing in on parton energy loss with charged particle spectra in Xe-Xe and Pb-Pb collisions with ALICE

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    For comparison, a pp reference at the collision energy of 5.44 TeV is obtained by interpolating between existing pp measurements at 5.02 and 7 TeV.  The nuclear modification factor in Xe-Xe collisions is compared to Pb-Pb collisions at 5.02 TeV and 2.76 TeV, showing remarkable similarity at pT > 10 GeV/c. The comparison of the measured nuclear mod...

  17. Modulation of ERG channels by XE991

    DEFF Research Database (Denmark)

    Elmedyb, Pernille; Calloe, Kirstine; Schmitt, Nicole

    2007-01-01

    In neuronal tissue, KCNQ2-5 channels conduct the physiologically important M-current. In some neurones, the M-current may in addition be conducted partly by ERG potassium channels, which have widely overlapping expression with the KCNQ channel subunits. XE991 and linopiridine are known to be stan......In neuronal tissue, KCNQ2-5 channels conduct the physiologically important M-current. In some neurones, the M-current may in addition be conducted partly by ERG potassium channels, which have widely overlapping expression with the KCNQ channel subunits. XE991 and linopiridine are known...... to be standard KCNQ potassium channel blockers. These compounds have been used in many different tissues as specific pharmacological tools to discern native currents conducted by KCNQ channels from other potassium currents. In this article, we demonstrate that ERG1-2 channels are also reversibly inhibited by XE......991 in the micromolar range (EC(50) 107 microM for ERG1). The effect has been characterized in Xenopus laevis oocytes expressing ERG1-2 and in the mammalian HEK293 cell line stably expressing ERG1 channels. The IC(50) values for block of KCNQ channels by XE991 range 1-65 microM. In conclusion, great...

  18. Stellar laboratories . VIII. New Zr iv-vii, Xe iv-v, and Xe vii oscillator strengths and the Al, Zr, and Xe abundances in the hot white dwarfs G191-B2B and RE 0503-289

    Science.gov (United States)

    Rauch, T.; Gamrath, S.; Quinet, P.; Löbling, L.; Hoyer, D.; Werner, K.; Kruk, J. W.; Demleitner, M.

    2017-03-01

    Context. For the spectral analysis of high-resolution and high-signal-to-noise spectra of hot stars, state-of-the-art non-local thermodynamic equilibrium (NLTE) model atmospheres are mandatory. These are strongly dependent on the reliability of the atomic data that is used for their calculation. Aims: To search for zirconium and xenon lines in the ultraviolet (UV) spectra of G191-B2B and RE 0503-289, new Zr iv-vii, Xe iv-v, and Xe vii oscillator strengths were calculated. This allows, for the first time, determination of the Zr abundance in white dwarf (WD) stars and improvement of the Xe abundance determinations. Methods: We calculated Zr iv-vii, Xe iv-v, and Xe vii oscillator strengths to consider radiative and collisional bound-bound transitions of Zr and Xe in our NLTE stellar-atmosphere models for the analysis of their lines exhibited in UV observations of the hot WDs G191-B2B and RE 0503-289. Results: We identified one new Zr iv, 14 new Zr v, and ten new Zr vi lines in the spectrum of RE 0503-289. Zr was detected for the first time in a WD. We measured a Zr abundance of -3.5 ± 0.2 (logarithmic mass fraction, approx. 11 500 times solar). We identified five new Xe vi lines and determined a Xe abundance of -3.9 ± 0.2 (approx. 7500 times solar). We determined a preliminary photospheric Al abundance of -4.3 ± 0.2 (solar) in RE 0503-289. In the spectra of G191-B2B, no Zr line was identified. The strongest Zr iv line (1598.948 Å) in our model gave an upper limit of -5.6 ± 0.3 (approx. 100 times solar). No Xe line was identified in the UV spectrum of G191-B2B and we confirmed the previously determined upper limit of -6.8 ± 0.3 (ten times solar). Conclusions: Precise measurements and calculations of atomic data are a prerequisite for advanced NLTE stellar-atmosphere modeling. Observed Zr iv-vi and Xe vi-vii line profiles in the UV spectrum of RE 0503-289 were simultaneously well reproduced with our newly calculated oscillator strengths. Based on observations

  19. High Sensitivity Detection of Xe Isotopes Via Beta-Gamma Coincidence Counting

    International Nuclear Information System (INIS)

    Bowyer, Ted W.; McIntyre, Justin I.; Reeder, Paul L.

    1999-01-01

    Measurement of xenon fission product isotopes is a key element in the global network being established to monitor the Comprehensive Nuclear-Test-Ban Treaty. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which includes a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. The counting geometry is nearly 100% for beta and conversion electrons. The resolution in the pulse height spectrum from the plastic scintillator is sufficient to observe distinct peaks for specific conversion electrons. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. Each of the four xenon isotopes has a distinctive signature in the two-dimensional energy array. The details of the counting system, examples of two-dimensional beta-gamma data, and operational experience with this counting system will be described

  20. Revised analysis of singly ionized xenon, Xe II

    International Nuclear Information System (INIS)

    Hansen, J.E.; Persson, W.

    1987-01-01

    We present a revised analysis of the spectrum of singly ionized xenon, Xe II. This spectrum has been reanalyzed on the basis of the wavelength material published by Drs J. C. Boyce and C. J. Humphreys. The latter has kindly placed the original wavelength list covering the wavelength range 10220-390 A at our disposal. We report 161 energy levels which have been identified on the basis of classifications of 950 lines. We report first f and g levels in Xe II. Also a number of g-factors have been determined for the first time and we give in total 75 g-factors. We have carried out least-squares fits to the even configurations and report the resulting parameter values and eigenvector compositions. A least-squares fit to the 5p 4 6p configuration is also reported. The levels have been named in jK and for many levels also in LS coupling. The former is the better coupling scheme for Xe II. We present an analysis of the 5s photoelectron satellite spectrum of Xe based on our calculated eigenvector compositions and calculations of transition probabilities for ground state transitions as well as lifetimes for the 6p levels. The latter are compared to recent experimental measurements. A list of wavelengths for observed laser transitions showing the present classifications and a discussion of the determination of the ionization potential of Xe II concludes the paper. (orig.)

  1. Saturated multikilovolt x-ray amplification with Xe clusters: single-pulse observation of Xe(L) spectral hole burning

    International Nuclear Information System (INIS)

    Borisov, Alex B; Davis, Jack; Song, Xiangyang; Koshman, Yevgeniya; Dai Yang; Boyer, Keith; Rhodes, Charles K

    2003-01-01

    Single-pulse measurements of spectral hole burning of Xe(L) 3d → 2p hollow atom transition arrays observed from a self-trapped plasma channel provide new information on the dynamics of saturated amplification in the λ ∼ 2.8-2.9 A region. The spectral hole burning on transitions in the Xe 34+ and Xe 35+ arrays reaches full suppression of the spontaneous emission and presents a corresponding width Δ h-bar ω x ∼ = 60 eV, a value adequate for efficient amplification of multikilovolt x-ray pulses down to a limiting length τ x ∼ 30 as. The depth of the suppression at 2.86 A indicates that the gain-to-loss ratio is ≥10. An independent determination of the x-ray pulse energy from damage produced on the surface of a Ti foil in the far field of the source gives a pulse energy of 20-30 μJ, a range that correlates well with the observation of the spectral hole burning and indicates an overall extraction efficiency of ∼10%. (letter to the editor)

  2. 124Iodine: A Longer-Life Positron Emitter Isotope—New Opportunities in Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Giuseppe Lucio Cascini

    2014-01-01

    Full Text Available 124Iodine (124I with its 4.2 d half-life is particularly attractive for in vivo detection and quantification of longer-term biological and physiological processes; the long half-life of 124I is especially suited for prolonged time in vivo studies of high molecular weight compounds uptake. Numerous small molecules and larger compounds like proteins and antibodies have been successfully labeled with 124I. Advances in radionuclide production allow the effective availability of sufficient quantities of 124I on small biomedical cyclotrons for molecular imaging purposes. Radioiodination chemistry with 124I relies on well-established radioiodine labeling methods, which consists mainly in nucleophilic and electrophilic substitution reactions. The physical characteristics of 124I permit taking advantages of the higher PET image quality. The availability of new molecules that may be targeted with 124I represents one of the more interesting reasons for the attention in nuclear medicine. We aim to discuss all iodine radioisotopes application focusing on 124I, which seems to be the most promising for its half-life, radiation emissions, and stability, allowing several applications in oncological and nononcological fields.

  3. Discharge efficiency in high-Xe-content plasma display panels

    NARCIS (Netherlands)

    Hayashi, D.; Kroesen, G.M.W.; Hagelaar, G.J.M.; Heusler, G.

    2004-01-01

    We study theoretically the overall output performance and the dominating reaction processes of the vacuum ultraviolet (UV) radiation production in high-Xe partial pressures in plasma display panels (PDPs) with Ne-Xe gas mixtures. A two-dimensional self-consistent fluid model is applied for the

  4. Modeling of Kr-Xe discharge of excimer lamp

    Directory of Open Access Journals (Sweden)

    Belasri A.

    2013-03-01

    Full Text Available This paper reports the numerical simulation of Dielectric Barrier Discharge (DBD for Kr-Xe excilamp. The model of the discharge consists of three main modules: a plasma chemistry module, a circuit module and a Boltzmann equation module. The results predict the optimal operating conditions and describe the electrical and chemical properties of the KrXe* excimer lamp.

  5. Nuclear structure studies in highly neutron-deficient (114,116)Xe

    Science.gov (United States)

    Degraaf, James Hendrick

    Lifetimes of nuclear states in 114Xe and 116Xe were measured for the first time; these nuclei represent the most neutron-deficient isotopes of xenon for which lifetimes have now been measured. The fusion-evaporation reactions 58Ni(60Ni, 2p)116Xe at 223 MeV beam energy and 58Ni(58Ni, 2p)114Xe at 215 MeV beam energy were used. Lifetimes were measured using the Recoil Distance Method (RDM) with the 8π gamma-ray spectrometer at Chalk River Laboratories. The new measurements of the B(E2;2+/to 0+) strength in these nuclei, coupled with the recent measurements for heavier xenon isotopes, are well described within the framework of the O(6) symmetry limit of the Interacting Boson Approximation. The octupole nature of the negative parity side-band was also studied, and the lifetime measurements indicate a change from a K/approx 3 structure in heavier xenon isotopes to a K/approx 0,/ 1 structure in 114Xe.

  6. XeBr excilamp based on a non-toxic component mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kelman, V A; Shpenik, Yu O; Zhmenyak, Yu V, E-mail: mironkle@rambler.ru [Institute of Electron Physics, National Academy of Sciences of Ukraine, Universitetska 21, 88017 Uzhgorod (Ukraine)

    2011-06-29

    This paper presents the results of experimental studies on obtaining UV luminescence of XeBr* molecules at the excitation of a non-toxic Xe-CsBr gas-vapour mixture by a longitudinal pulse-periodic discharge. Effective UV emission yield of the exciplex XeBr* molecules (spectral maximum at 282 nm) is observed within a wide range of excitation conditions. The spectral distribution in the UV emission under the optimal excitation conditions does not differ essentially from that in other XeBr excilamps based on toxic components. The emission of the B {yields} X band of the XeBr* molecules provides the main contribution to the total power of the discharge UV emission. The determined average power of the UV emission for the experimental discharge tube is 12 W at an efficiency of 1%. Spectral, power-related and time-dependent parameters of the laboratory excilamp are presented for a wide range of excitation parameters. A new mechanism of exciplex molecule formation at the excitation of a rare gas/alkali halide vapour mixture is discussed.

  7. XeBr excilamp based on a non-toxic component mixture

    International Nuclear Information System (INIS)

    Kelman, V A; Shpenik, Yu O; Zhmenyak, Yu V

    2011-01-01

    This paper presents the results of experimental studies on obtaining UV luminescence of XeBr* molecules at the excitation of a non-toxic Xe-CsBr gas-vapour mixture by a longitudinal pulse-periodic discharge. Effective UV emission yield of the exciplex XeBr* molecules (spectral maximum at 282 nm) is observed within a wide range of excitation conditions. The spectral distribution in the UV emission under the optimal excitation conditions does not differ essentially from that in other XeBr excilamps based on toxic components. The emission of the B → X band of the XeBr* molecules provides the main contribution to the total power of the discharge UV emission. The determined average power of the UV emission for the experimental discharge tube is 12 W at an efficiency of 1%. Spectral, power-related and time-dependent parameters of the laboratory excilamp are presented for a wide range of excitation parameters. A new mechanism of exciplex molecule formation at the excitation of a rare gas/alkali halide vapour mixture is discussed.

  8. The interaction between Xe and F in Si (1 0 0) pre-amorphised with 20 keV Xe and implanted with low energy BF{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Werner, M. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom)]. E-mail: m.werner@pgr.salford.ac.uk; Berg, J.A. van den [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Armour, D.G. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Carter, G. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Feudel, T. [AMD Saxony LLC and Co. KG, Wilschdorfer Landstrasse, 101 D-01109 Dresden (Italy); Herden, M. [AMD Saxony LLC and Co. KG, Wilschdorfer Landstrasse, 101 D-01109 Dresden (Italy); Bersani, M. [ITC IRST, 38050 Povo, Trento (Italy); Giubertoni, D. [ITC IRST, 38050 Povo, Trento (Italy); Bailey, P. [CCLRC Daresbury Laboratory, Daresbury WA44A (United Kingdom); Noakes, T.C.Q. [CCLRC Daresbury Laboratory, Daresbury WA44A (United Kingdom)

    2004-12-15

    The pre-amorphisation of Si by Xe{sup +} ions, before source/drain and extension implants, is an attractive alternative to Ge{sup +} or Si{sup +}, as it produces sharper amorphous/crystalline interfaces. Si (1 0 0) samples pre-amorphised with 20 keV Xe{sup +} to a nominal dose of 2E14 cm{sup -2} were implanted with 1 and 3 keV BF{sub 2} {sup +} to doses of 7E14 cm{sup -2}. Samples were annealed at temperatures ranging from 600 to 1130 deg. C and investigated by medium energy ion scattering (MEIS) and secondary ion mass spectrometry (SIMS). Following annealing, it was observed that implanted Xe has interacted with F originating from the BF{sub 2} {sup +} implant. MEIS studies showed that for all annealing conditions, approximately half of the Xe accumulated at depths of 7 nm for the 1 keV and at 13 nm for the 3 keV BF{sub 2} {sup +} implant. This equates to the end of range of B and F within the amorphous Si. SIMS showed that in the pre-amorphised samples, approximately 10% of the F migrates into the bulk and is trapped at the same depth in a {approx}1:1 ratio to Xe. A small fraction of the implanted B is also trapped. The effect is interpreted in terms of the formation of a defect structure within the amorphised Si, leading to F stabilised Xe bubble or XeF compound formation.

  9. Fourier photospectroscopy of Xe-C60 through a Xe 4d resonance window: theory versus recent experiment

    International Nuclear Information System (INIS)

    Patel, Aakash B; Chakraborty, Himadri S

    2011-01-01

    The photoionization cross section of endohedral Xe-C 60 over a Xe 4d giant resonance energy region, calculated in the time-dependent local density approximation, is compared with recent measurements (Kilcoyne et al 2010 Phys. Rev. Lett. 105 213001). An analysis based on the Fourier transforms of oscillatory cross sections is performed to derive a number of inherent similarities between the prediction and the data, including a large beating-type oscillation and several others of intermediate size. Results stress the need for more accurate measurements to access the wealth of information about the geometry of the system. (fast track communication)

  10. Regional lung function (133Xe-radiospirometry) in bronchial cancer

    International Nuclear Information System (INIS)

    Arborelius, M.; Kristersson, S.; Lindell, S.E.

    1976-01-01

    In a prospective study of all patients with bronchial cancer in the city of Malmoe, all patients considered for surgery were examined with regard to overall function (conventional spirometry) and regional lung function (133-Xe-radiospirometry). Out of 116 consecutive cases examined with 133-Xe-radiospirometry before surgery,

  11. PandaX-III: Searching for neutrinoless double beta decay with high pressure 136Xe gas time projection chambers

    Science.gov (United States)

    Chen, Xun; Fu, ChangBo; Galan, Javier; Giboni, Karl; Giuliani, Franco; Gu, LingHui; Han, Ke; Ji, XiangDong; Lin, Heng; Liu, JiangLai; Ni, KaiXiang; Kusano, Hiroki; Ren, XiangXiang; Wang, ShaoBo; Yang, Yong; Zhang, Dan; Zhang, Tao; Zhao, Li; Sun, XiangMing; Hu, ShouYang; Jian, SiYu; Li, XingLong; Li, XiaoMei; Liang, Hao; Zhang, HuanQiao; Zhao, MingRui; Zhou, Jing; Mao, YaJun; Qiao, Hao; Wang, SiGuang; Yuan, Ying; Wang, Meng; Khan, Amir N.; Raper, Neill; Tang, Jian; Wang, Wei; Dong, JiaNing; Feng, ChangQing; Li, Cheng; Liu, JianBei; Liu, ShuBin; Wang, XiaoLian; Zhu, DanYang; Castel, Juan F.; Cebrián, Susana; Dafni, Theopisti; Garza, Javier G.; Irastorza, Igor G.; Iguaz, Francisco J.; Luzón, Gloria; Mirallas, Hector; Aune, Stephan; Berthoumieux, Eric; Bedfer, Yann; Calvet, Denis; d'Hose, Nicole; Delbart, Alain; Diakaki, Maria; Ferrer-Ribas, Esther; Ferrero, Andrea; Kunne, Fabienne; Neyret, Damien; Papaevangelou, Thomas; Sabatié, Franck; Vanderbroucke, Maxence; Tan, AnDi; Haxton, Wick; Mei, Yuan; Kobdaj, Chinorat; Yan, Yu-Peng

    2017-06-01

    Searching for the neutrinoless double beta decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (particle and astrophysical xenon experiment III) will search for the NLDBD of 136Xe at the China Jin Ping Underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% 136Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct the electron tracks of the NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure 5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.

  12. Kr and Xe isotopes from spontaneous fission of 248Cm and 250Cf

    International Nuclear Information System (INIS)

    Srinivasan, B.

    1980-01-01

    Relative yields of Kr and Xe isotopes from the spontaneous fission of 248 Cm and 250 Cf have been determined mass spectrometrically. The yields are as follows: 83 Kr/ 84 Kr/ 85 Kr/ 86 Kr = 0.223/0.458/0.596/ identical 1.00 and 0.306/0.582/0.793/ identical 1.00; 131 Xe/ 134 Xe/ 136 Xe = 0.486/0.819/1.075 identical 1.00 and 0.343/0.506/0.851/ identical 1.00 from 248 Cm and 250 Cf, respectively. The Xe yields from 248 Cm agree with an earlier determination by Leich et al. Neither of these yield patterns matches that of fissiogenic Kr and Xe in carbonaceous chondrites and hence 248 Cm and 250 Cf are ruled out as progenitors of the meteoritic Kr and Xe. In general, none of the spontaneously fissioning nuclides of actinide elements can be identified as a possible progenitor. Even the mixtures of actinides, including a combination of 248 Cm and 250 Cm, are unsuitable. The origin of anomalous Kr and Xe in carbonaceous chondrites must then be traced either to the spontaneous fission of a superheavy element or to peculiarities in specific nucleosynthetic reactions. (orig.)

  13. Molecular dynamics simulation of Xe bubble nucleation in nanocrystalline UO2 nuclear fuel

    International Nuclear Information System (INIS)

    Moore, Emily; René Corrales, L.; Desai, Tapan; Devanathan, Ram

    2011-01-01

    Highlights: ► We simulated the interactions of defects and fission gas with grain boundaries in nuclear fuel. ► We observed the formation of Xe bubble nuclei that are difficult to observe experimentally. ► The bubble nuclei form by vacancy-assisted diffusion of Xe atoms. ► We also observed the initial stages of grain boundary motion. ► The study offers insights to the design of nuclear fuel to control fission gas release. - Abstract: We have performed molecular dynamics (MD) simulations to investigate the dynamical interactions between vacancy defects, fission gas atoms (Xe), and grain boundaries in a model of polycrystalline UO 2 nuclear fuel with average grain diameter of about 20 nm. We followed the mobility and aggregation of Xe atoms in the vacancy-saturated model compound for up to 2 ns. During this time we observed the aggregation of Xe atoms into nuclei, which are possible precursors to Xe bubbles. The nucleation was driven by the migration of Xe atoms via vacancy-assisted diffusion. The Xe clusters aggregate faster than grain boundary diffusion rates and are smaller than experimentally observed bubbles. As the system evolves towards equilibrium, the Xe atom cluster growth slows down significantly, and the lattice relaxes around the cluster. These simulations provide insights into fundamental physical processes that are inaccessible to experiment.

  14. 129 Xe-NMR of carbon black filled elastomers

    International Nuclear Information System (INIS)

    Sperling-Ischinsky, K.; Veeman, W.S.

    1999-01-01

    It is shown that 129 Xe-NMR is a powerful tool to investigate carbon black and carbon black filled elastomers. For the carbon black material itself the 129 Xe chemical shift of xenon adsorbed at the surface of carbon black aggregates yields information about the relative average pore size of the carbon black aggregates. The experimental 129 Xe-NMR results of carbon black filled ethylene-propylene-diene (EPDM) can be explained when it is assumed that the xenon atoms in the bound EPDM fraction exchange rapidly on the NMR time scale between a state where they are adsorbed on the carbon black surface and a state in which they are absorbed in the EPDM layer. This would imply that the carbon black aggregates are not completely covered with EPDM chains. (author)

  15. Level structures of neutron-rich Xe isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I.; Lister, C.J.; Morss, L.R. [and others

    1995-08-01

    The level structures of neutron-rich Xe isotopes were determined by observing prompt gamma-ray coincidences in {sup 248}Cm fission fragments. A 5-mg {sup 248}Cm, in the form of {sup 248}Cm-KCl pellet, was placed inside Eurogam array which consisted of 45 Compton-suppressed Ge detectors and 5 Low-Energy Photon Spectrometers. Transitions in Xe isotopes were identified by the appearance of new peaks in the {gamma}-ray spectra obtained by gating on the gamma peaks of the complementary Mo fragments.

  16. MiR-124 down-regulation is critical for cancer associated fibroblasts-enhanced tumor growth of oral carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xia, E-mail: dentistlx@163.com [Department of Stomatology, School of Stomatology and medicine, Foshan Stomatology Hospital, Foshan University, Foshan 528000 (China); Fan, Qinqiao [Department of Hepatobiliary Surgery, Cancer Center, Chenzhou No.1 People' s Hospital, Chenzhou 423000 (China); Li, Jinyun [Department of Head and Neck Surgery, The Affiliated Cancer Hospital of Xiangya School of Medicine, Center South University, Changsha 410013 (China); Song, Jing; Gu, Yangcong [Department of Stomatology, School of Stomatology and medicine, Foshan Stomatology Hospital, Foshan University, Foshan 528000 (China)

    2017-02-01

    Cancer associated fibroblasts (CAFs) are known to be involved in initiation, progression and metastasis of various cancers. However, the molecular mechanism of how CAFs affects the biological function of oral cancer (OC) has not been fully-addressed. In this study, we demonstrated that miR-124 was downregulated in oral CAFs and oral cancer cells (OCCs) when compared with matched normal fibroblasts (NFs). Hypermethylation in the promoter region of miR-124 genes was accounted for its downregulation. Interestingly, CAFs but not NFs exerted promotion effect on OCCs cell proliferation, migration and tumor growth in CAFs/NFs-OCCs co-culture. Furthermore, we identified Chemokine (C-C motif) ligand 2 (CCL2) and Interleukin 8 (IL-8) as two direct targets of miR-124. Over-expression of miR-124 in CAFs-OCCs co-culture abrogated CAFs-promoted OCCs cell growth and migration, and this inhibitory effect can be rescued by addition of CCL2 and IL-8. Finally, we showed that restoration of miR-124 expression by lentiviral infection or formulated miR-124 injection inhibited oral tumor growth in vivo suggesting miR-124 rescue could be a potential rationale for therapeutic applications in oral cancer in the future. - Highlights: • miR-124 was downregulated in oral cancer cells and cancer associated fibroblasts. • Hypermethylation in the promoter region was accounted for miR-124 downregulation. • CCL2 and IL-8 are two direct targets of miR-124. • miR-124 rescue could be a potential rationale for oral cancer therapy.

  17. MiR-124 down-regulation is critical for cancer associated fibroblasts-enhanced tumor growth of oral carcinoma

    International Nuclear Information System (INIS)

    Li, Xia; Fan, Qinqiao; Li, Jinyun; Song, Jing; Gu, Yangcong

    2017-01-01

    Cancer associated fibroblasts (CAFs) are known to be involved in initiation, progression and metastasis of various cancers. However, the molecular mechanism of how CAFs affects the biological function of oral cancer (OC) has not been fully-addressed. In this study, we demonstrated that miR-124 was downregulated in oral CAFs and oral cancer cells (OCCs) when compared with matched normal fibroblasts (NFs). Hypermethylation in the promoter region of miR-124 genes was accounted for its downregulation. Interestingly, CAFs but not NFs exerted promotion effect on OCCs cell proliferation, migration and tumor growth in CAFs/NFs-OCCs co-culture. Furthermore, we identified Chemokine (C-C motif) ligand 2 (CCL2) and Interleukin 8 (IL-8) as two direct targets of miR-124. Over-expression of miR-124 in CAFs-OCCs co-culture abrogated CAFs-promoted OCCs cell growth and migration, and this inhibitory effect can be rescued by addition of CCL2 and IL-8. Finally, we showed that restoration of miR-124 expression by lentiviral infection or formulated miR-124 injection inhibited oral tumor growth in vivo suggesting miR-124 rescue could be a potential rationale for therapeutic applications in oral cancer in the future. - Highlights: • miR-124 was downregulated in oral cancer cells and cancer associated fibroblasts. • Hypermethylation in the promoter region was accounted for miR-124 downregulation. • CCL2 and IL-8 are two direct targets of miR-124. • miR-124 rescue could be a potential rationale for oral cancer therapy.

  18. Decay of 132Cs and nuclear structure of 132Xe

    International Nuclear Information System (INIS)

    Cruz, M.T.F. da; Goldman, I.D.

    1989-02-01

    Gamma spectroscopy, coincidence and angular correlation experiments were performed, in an extensive study of 132 Cs decay. The population intensities of states in 132 Ba were measured, some upper limits were determined and the value of the transition to the 4 1 + state of 132 Ba has drastically changed. A new gamma transition of 688 KeV was detected and located in the level scheme of 132 Xe. The angular correlation measurements were performed with a Ge(Li)-NaI(Tl) spectrometer and helped in choosing the spin value for the 1804 KeV state of 132 Xe. Kumar-Baranger-type calculations were performed for the 132 Xe fairly good results. The resulting potential energy surface for 132 Xe is very different from that of Gneuss and Greiner model, suggesting the need for any quadrupole moment measurement for this nucleus. (author) [pt

  19. Imaging Human Brain Perfusion with Inhaled Hyperpolarized 129Xe MR Imaging.

    Science.gov (United States)

    Rao, Madhwesha R; Stewart, Neil J; Griffiths, Paul D; Norquay, Graham; Wild, Jim M

    2018-02-01

    Purpose To evaluate the feasibility of directly imaging perfusion of human brain tissue by using magnetic resonance (MR) imaging with inhaled hyperpolarized xenon 129 ( 129 Xe). Materials and Methods In vivo imaging with 129 Xe was performed in three healthy participants. The combination of a high-yield spin-exchange optical pumping 129 Xe polarizer, custom-built radiofrequency coils, and an optimized gradient-echo MR imaging protocol was used to achieve signal sensitivity sufficient to directly image hyperpolarized 129 Xe dissolved in the human brain. Conventional T1-weighted proton (hydrogen 1 [ 1 H]) images and perfusion images by using arterial spin labeling were obtained for comparison. Results Images of 129 Xe uptake were obtained with a signal-to-noise ratio of 31 ± 9 and demonstrated structural similarities to the gray matter distribution on conventional T1-weighted 1 H images and to perfusion images from arterial spin labeling. Conclusion Hyperpolarized 129 Xe MR imaging is an injection-free means of imaging the perfusion of cerebral tissue. The proposed method images the uptake of inhaled xenon gas to the extravascular brain tissue compartment across the intact blood-brain barrier. This level of sensitivity is not readily available with contemporary MR imaging methods. © RSNA, 2017.

  20. Quadrupole photoionization of endohedral Xe-C60

    International Nuclear Information System (INIS)

    Govil, Karan; Deshmukh, P C

    2009-01-01

    The effect of an endohedral confinement on the quadrupole photoionization of atomic Xe is studied using the relativistic random phase approximation (RRPA). The atom's confinement is modelled by placing atomic Xe at the centre of a C 60 cage represented by an annular potential around it. A new confinement resonance is reported in the 4p quadrupole cross-section along with 'correlation confinement resonances' in 4d, 5s and 5p photoionizations at about 185 eV. The effect of the confinement on the non-dipole photoelectron angular distribution parameter γ is also reported.

  1. Fourier photospectroscopy of Xe-C{sub 60} through a Xe 4d resonance window: theory versus recent experiment

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Aakash B; Chakraborty, Himadri S, E-mail: himadri@nwmissouri.edu [Center for Innovation and Entrepreneurship, Department of Chemistry and Physics, Northwest Missouri State University, Maryville, Missouri 64468 (United States)

    2011-10-14

    The photoionization cross section of endohedral Xe-C{sub 60} over a Xe 4d giant resonance energy region, calculated in the time-dependent local density approximation, is compared with recent measurements (Kilcoyne et al 2010 Phys. Rev. Lett. 105 213001). An analysis based on the Fourier transforms of oscillatory cross sections is performed to derive a number of inherent similarities between the prediction and the data, including a large beating-type oscillation and several others of intermediate size. Results stress the need for more accurate measurements to access the wealth of information about the geometry of the system. (fast track communication)

  2. 129Xe on the outgassing of the atmosphere

    International Nuclear Information System (INIS)

    Thomsen, L.

    1980-01-01

    Because of the short half-life of its parent ( 129 I, 17 m.y.) and its own chemical inertness, 129 Xe offers unique insight into the problem of the outgassing history of the earth's atmosphere. Because the current atmosphere is different in Xe isotopic patterns than is the interior, the present atmosphere must have been largely outgassed before these patterns finished changing, that is, very early in earth history. Furthermore, there can have been no significant delay in the onset of outgassing; that is, the earth must have been initially hot. Because ancient sedimentary rocks indicate that the atmospheric Xe patterns have not changed substantially for over 3 b.y., models presuming a separate, lower mantle reservoir do not alter these conclusions. Similar conclusions have been reached before but have always carried a heavier burden of debatable assumptions

  3. Optical properties of implanted Xe color centers in diamond

    Science.gov (United States)

    Sandstrom, Russell; Ke, Li; Martin, Aiden; Wang, Ziyu; Kianinia, Mehran; Green, Ben; Gao, Wei-bo; Aharonovich, Igor

    2018-03-01

    Optical properties of color centers in diamond have been the subject of intense research due to their promising applications in quantum photonics. In this work we study the optical properties of Xe related color centers implanted into nitrogen rich (type IIA) and an ultrapure, electronic grade diamond. The Xe defect has two zero phonon lines at ∼794 nm and 811 nm, which can be effectively excited using both green and red excitation, however, its emission in the nitrogen rich diamond is brighter. Near resonant excitation is performed at cryogenic temperatures and luminescence is probed under strong magnetic field. Our results are important towards the understanding of the Xe related defect and other near infrared color centers in diamond.

  4. Radiation dosimetry and first therapy results with a 124I/131I-labeled small molecule (MIP-1095) targeting PSMA for prostate cancer therapy

    International Nuclear Information System (INIS)

    Zechmann, Christian M.; Afshar-Oromieh, Ali; Mier, Walter; Armor, Tom; Joyal, John; Stubbs, James B.; Hadaschik, Boris; Kopka, Klaus; Debus, Juergen; Babich, John W.; Haberkorn, Uwe

    2014-01-01

    Since the prostate-specific membrane antigen (PSMA) is frequently over-expressed in prostate cancer (PCa) several PSMA-targeting molecules are under development to detect and treat metastatic castration resistant prostate cancer (mCRPC). We investigated the tissue kinetics of a small molecule inhibitor of PSMA ((S)-2-(3-((S)-1-carboxy-5-(3-(4-[ 124 I]iodophenyl)ureido)pentyl)ureido) pentan edioicacid; MIP-1095) using PET/CT to estimate radiation dosimetry for the potential therapeutic use of 131 I-MIP-1095 in men with mCRPC. We also report preliminary safety and efficacy of the first 28 consecutive patients treated under a compassionate-use protocol with a single cycle of 131 I-MIP-1095. Sixteen patients with known prostate cancer underwent PET/CT imaging after i.v. administration of 124 I-MIP-1095 (mean activity: 67.4 MBq). Each patient was scanned using PET/CT up to five times at 1, 4, 24, 48 and 72 h post injection. Volumes of interest were defined for tumor lesions and normal organs at each time point followed by dose calculations using the OLINDA/EXM software. Twenty-eight men with mCRPC were treated with a single cycle of 131 I-MIP-1095 (mean activity: 4.8 GBq, range 2 to 7.2 GBq) and followed for safety and efficacy. Baseline and follow up examinations included a complete blood count, liver and kidney function tests, and measurement of serum PSA. I-124-MIP-1095 PET/CT images showed excellent tumor uptake and moderate uptake in liver, proximal intestine and within a few hours post-injection also in the kidneys. High uptake values were observed only in salivary and lacrimal glands. Dosimetry estimates for I-131-MIP-1095 revealed that the highest absorbed doses were delivered to the salivary glands (3.8 mSv/MBq), liver (1.7 mSv/MBq) and kidneys (1.4 mSv/MBq). The absorbed dose calculated for the red marrow was 0.37 mSv/MBq. PSA values decreased by >50 % in 60.7 % of the men treated. Of men with bone pain, 84.6 % showed complete or moderate reduction in pain

  5. Damage evolution in Xe-ion irradiated rutile (TiO2) single crystals

    International Nuclear Information System (INIS)

    Li, F.; Sickafus, K.E.; Evans, C.R.; Nastasi, M.

    1999-01-01

    Rutile (TiO 2 ) single crystals with (110) orientation were irradiated with 360 keV Xe 2+ ions at 300 K to fluences ranging from 2 x 10 19 to 1 x 10 20 Xe/m 2 . Irradiated samples were analyzed using: (1) Rutherford backscattering spectroscopy combined with ion channeling analysis (RBS/C); and (2) cross-sectional transmission electron microscopy (XTEM). Upon irradiation to a fluence of 2 x 10 19 Xe/m 2 , the sample thickness penetrated by the implanted ions was observed to consist of three distinct layers: (1) a defect-free layer at the surface (thickness about 12 nm) exhibiting good crystallinity; (2) a second layer with a low density of relatively large-sized defects; and (3) a third layer consisting of a high concentration of small defects. After the fluence was increased to 7 x 10 19 Xe/m 2 , a buried amorphous layer was visible by XTEM. The thickness of the amorphous layer was found to increase with increasing Xe ion fluence. The location of this buried amorphous layer was found to coincide with the measured peak in the Xe concentration (measured by RBS/C), rather than with the theoretical maximum in the displacement damage profile. This observation suggests the implanted Xe ions may serve as nucleation sites for the amorphization transformation. The total thickness of the damaged microstructure due to ion irradiation was always found to be much greater than the projected range of the Xe ions. This is likely due to point defect migration under the high stresses induced by ion implantation

  6. Fully stripped heavy ion yield vs energy for Xe and Au ions

    International Nuclear Information System (INIS)

    Thieberger, P.; Wegner, H.E.; Alonzo, J.; Gould, H.; Anholt, R.E.; Meyerhof, W.E.

    1985-01-01

    The Bevalac is now capable of accelerating U-238 ions to approximately 1 GeV/amu and measurements have shown that fully stripped U-238 ions are produced with good yield at these energies. However, knowing the stripping yields at different energies for U-238 does not allow an accurate prediction for other, lower Z projectiles. Consequently, extensive stripping yield measurements were made for Au-197 and Xe-139 ions. In addition to the stripping measurements from the direct Bevalac beam, pickup measurements were also made with specially prepared bare, one electron, and two electron ions. Since many research groups are considering heavy ion storage rings and/or synchrotrons, the pickup cross section for bare ions is important to estimate beam lifetime in terms of the average machine vacuum. Since the Mylar target provides a pickup probability similar to air, a preliminary analysis of the Xe 54+ and U 92+ data are presented along with predictions for other ions ranging down to Fe 26+ . 11 refs., 3 figs., 1 tab

  7. Fully stripped heavy ion yield vs energy for Xe and Au ions

    Energy Technology Data Exchange (ETDEWEB)

    Thieberger, P.; Wegner, H.E.; Alonzo, J.; Gould, H.; Anholt, R.E.; Meyerhof, W.E.

    1985-01-01

    The Bevalac is now capable of accelerating U-238 ions to approximately 1 GeV/amu and measurements have shown that fully stripped U-238 ions are produced with good yield at these energies. However, knowing the stripping yields at different energies for U-238 does not allow an accurate prediction for other, lower Z projectiles. Consequently, extensive stripping yield measurements were made for Au-197 and Xe-139 ions. In addition to the stripping measurements from the direct Bevalac beam, pickup measurements were also made with specially prepared bare, one electron, and two electron ions. Since many research groups are considering heavy ion storage rings and/or synchrotrons, the pickup cross section for bare ions is important to estimate beam lifetime in terms of the average machine vacuum. Since the Mylar target provides a pickup probability similar to air, a preliminary analysis of the Xe/sup 54 +/ and U/sup 92 +/ data are presented along with predictions for other ions ranging down to Fe/sup 26 +/. 11 refs., 3 figs., 1 tab.

  8. Autoradiolytic decomposition and reductant-free sodium sup 124 I- and sup 123 I-iodide

    Energy Technology Data Exchange (ETDEWEB)

    Sajjad, M.; Lambrecht, R.M.; Bakr, S.A. (King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia). Radionuclide and Cyclotron Operations)

    1990-01-01

    The presence of salts and metal cations in {sup 124}I- and {sup 123}I-sodium iodide solutions separated from {sup 124}Te targets promots autoradiolytic decomposition of iodide to several different iodine species dependent upon the chemical environment. The stabilization of the radioiodine as iodide by removal of trace salts and trace metal cations and in the absence of reducing agents is described. The high specific activity {sup 123}I- and {sup 124}I-iodide is suitable for labeling antibodies, proteins and radiopharmaceuticals. (orig.).

  9. The permanent electric dipole moment of the neutron and atomic 129Xe

    International Nuclear Information System (INIS)

    Heckel, B.

    1984-01-01

    Recently the Seattle group has measured the permanent edm of atomic 129 Xe to be d /sub Xe/ = (-0.3 + or - 1.1) x 10 -26 cm. This measurement provides an improvement by a factor of 10 4 over the best previous measurement of an atomic edm. The edm of Xe is most sensitive to a T-violating electron-nucleon interaction, but can also be generated by an intrinsic electron edm or an edm of the Xe nucleus. In the second half of this presentation, each of these mechanisms will be briefly discussed and a description of the experiment will be given

  10. PET-based compartmental modeling of {sup 124}I-A33 antibody: quantitative characterization of patient-specific tumor targeting in colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zanzonico, Pat; O' Donoghue, Joseph A.; Humm, John L. [Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, NY (United States); Carrasquillo, Jorge A.; Pandit-Taskar, Neeta; Ruan, Shutian; Larson, Steven M. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Smith-Jones, Peter [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Stony Brook School of Medicine, Departments of Psychiatry and Radiology, Stony Brook, NY (United States); Divgi, Chaitanya [Columbia University Medical Center, New York, NY (United States); Scott, Andrew M. [La Trobe University, Olivia Newton-John Cancer Research Institute, Melbourne (Australia); Kemeny, Nancy E.; Wong, Douglas; Scheinberg, David [Memorial Sloan Kettering Cancer Center, Department of Medicine, New York, NY (United States); Fong, Yuman [Memorial Sloan Kettering Cancer Center, Department of Surgery, New York, NY (United States); City of Hope, Department of Surgery, Duarte, CA (United States); Ritter, Gerd; Jungbluth, Achem; Old, Lloyd J. [Memorial Sloan Kettering Cancer Center, Ludwig Institute for Cancer Research, New York, NY (United States)

    2015-10-15

    The molecular specificity of monoclonal antibodies (mAbs) directed against tumor antigens has proven effective for targeted therapy of human cancers, as shown by a growing list of successful antibody-based drug products. We describe a novel, nonlinear compartmental model using PET-derived data to determine the ''best-fit'' parameters and model-derived quantities for optimizing biodistribution of intravenously injected {sup 124}I-labeled antitumor antibodies. As an example of this paradigm, quantitative image and kinetic analyses of anti-A33 humanized mAb (also known as ''A33'') were performed in 11 colorectal cancer patients. Serial whole-body PET scans of {sup 124}I-labeled A33 and blood samples were acquired and the resulting tissue time-activity data for each patient were fit to a nonlinear compartmental model using the SAAM II computer code. Excellent agreement was observed between fitted and measured parameters of tumor uptake, ''off-target'' uptake in bowel mucosa, blood clearance, tumor antigen levels, and percent antigen occupancy. This approach should be generally applicable to antibody-antigen systems in human tumors for which the masses of antigen-expressing tumor and of normal tissues can be estimated and for which antibody kinetics can be measured with PET. Ultimately, based on each patient's resulting ''best-fit'' nonlinear model, a patient-specific optimum mAb dose (in micromoles, for example) may be derived. (orig.)

  11. Autoantigens targeted in scleroderma patients with vascular disease are enriched in endothelial lineage cells

    Science.gov (United States)

    McMahan, Zsuzsanna H.; Cottrell, Tricia R.; Wigley, Fredrick M.; Antiochos, Brendan; Zambidis, Elias T.; Park, Tea Soon; Halushka, Marc K.; Gutierrez-Alamillo, Laura; Cimbro, Raffaello; Rosen, Antony; Casciola-Rosen, Livia

    2016-01-01

    Objective Scleroderma patients with autoantibodies to centromere proteins (CENPs) and/or interferon-inducible protein 16 (IFI16) are at increased risk of severe vascular complications. We set out to define whether these autoantigens are enriched in cells of the vasculature. Methods Successive stages of embryoid bodies (EBs) as well as vascular progenitors were used to evaluate the expression of scleroderma autoantigens IFI16 and CENP by immunoblotting. CD31 was included to mark early blood vessels. IFI16 and CD31 expression were defined in skin paraffin sections from scleroderma patients and from healthy controls. IFI16 expression was determined by flow cytometry in circulating endothelial cells (CECs) and circulating progenitor cells (CPCs). Results Expression of CENP-A, IFI16 and CD31 was enriched in EBs at days 10 and 12 of differentiation, and particularly in cultures enriched in vascular progenitors (IFI16, CD31, CENPs A and-B). This pattern was distinct from that of comparator autoantigens. Immunohistochemical staining of skin paraffin sections showed enrichment of IFI16 in CD31-positive vascular endothelial cells in biopsies from scleroderma patients and normal controls. Flow cytometry analysis revealed IFI16 expression in CPCs, but minimal expression in CECs. Conclusion Expression of scleroderma autoantigens IFI16 and CENPs, which are associated with severe vascular disease, is increased in vascular progenitors and mature endothelial cells. High level, lineage-enriched expression of autoantigens may explain the striking association between clinical phenotypes and the immune targeting of specific autoantigens. PMID:27159521

  12. Analysis of XeC1 Emission in a Hollow Cathode Discharge.

    Science.gov (United States)

    1981-06-01

    excited homopolar molecule, e.g., Xe2 , Hg2 The term exciplex refers to an electronically excited heteropolar complex, e.g., KrF , XeOH , XeCl , which...frequently overlooked and both homopolar and heteropolar systems are commonly referred to as excimers, Excimers are formed by the interaction between two...mode and a non-scanning mode. Scanning is performed using a 1 rpm motor and produces plots of in- tensity versus wavelength. The non-scanning mode is

  13. Effect of high Xe-concentration in a plasma display panel with a SrCaO cold cathode

    International Nuclear Information System (INIS)

    Uchida, Giichiro; Kajiyama, Hiroshi; Shinoda, Tsutae; Uchida, Satoshi; Akiyama, Toshiyuki

    2010-01-01

    We present here measurements of high Xe-contents plasma display panel (PDP) with SrCaO cold cathode. Luminous efficacy (η) shows a two-step increase with Xe-concentration in Ne/Xe gas mixture: η drastically increases up to Xe-concentration of 30% (Xe: 30%), and then attains 5 lm/W at the highest Xe-concentration of Xe: 100%. The high performance PDP with Xe: 100% can be operated at low applied voltage between 230 and 377 V due to the high secondary electron emission from the SrCaO cathode. Emission measurements clearly show the change in discharge characteristics at Xe: 30%, where the discharge changes from a Ne/Xe mixture discharge to an almost pure Xe discharge, and the vacuum ultraviolet (VUV) radiation from the combination of resonance and excimer radiations to only excimer radiation. Theoretical analysis solving Boltzmann equation for electron demonstrates that increasing Xe-concentration enhances the collision frequency for electron impact excitation directly from ground state to lower levels concerned with the VUV radiation, resulting in a drastic increase in luminous efficacy up to Xe: 30%. Also, one-dimensional fluid simulation of a Ne/Xe dielectric barrier discharge clearly shows that a combination of high secondary electron emission cathode and high Xe-concentration is quite effective for high VUV radiation efficiency because it induces a drastic increase in electron-heating efficiency.

  14. Fusion barrier distributions in 28,30Si + 124Sn reactions

    International Nuclear Information System (INIS)

    Danu, L.S.; Nayak, B.K.; Biswas, D.C.; Saxena, A.; Thomas, R.G.; Mirgule, E.T.; Choudhury, R.K.

    2009-01-01

    The coupling of various degrees of freedom such as static deformation, inelastic excitation and nucleon transfer with the relative motion gives rise to a distribution of barrier in heavy ion induced fusion reactions. The barrier distribution is a fingerprint of the reaction characterizing the important channel couplings. The relative importance of various couplings in fusion reaction is of topical interest. In an earlier study with deformed projectiles 28,30 Si on 115 In target, it was observed that the barrier distributions get affected due to coulomb reorientation of the deformed projectile nuclei in the field of target nucleus thus giving rise to fusion hindrance at sub-barrier energies. In that study, we considered deformed projectile rotational and positive Q-value transfer channel couplings to relative motion in fusion for investigation of Coulomb reorientation and no inelastic coupling of the 115 In target was considered. In the present work, we have extended the measurements with 124 Sn target and inelastic coupling of target has been considered in the coupled channel calculations. The fusion barrier distributions for 28,30 Si + 124 Sn systems have been obtained by quasi-elastic scattering measurements at backward angles and the results compared with the predictions of coupled channel calculations

  15. Analysis and characterization of heavy residues produced in 129Xe + natSn reactions between 8 and 25 AMeV

    International Nuclear Information System (INIS)

    Moisan, J.

    2008-06-01

    Studies with the INDRA multidetector of the 129 Xe + nat Sn reactions showed the unexpected existence of heavy fragments with a charge as large as Z=70. The charges of Xe and Sn are 54 and 50 respectively. Reactions between nuclei with a charge product greater than 2700 are dominated by deep inelastic collisions. For Xe + Sn the product is exactly 2700. After these observations, 129 Xe + nat Sn reactions at 8, 12, 15, 20 and 25 AMeV have been done. It will then be possible to clarify if the heavy residues are formed by an incomplete fusion, massive transfers occurring in deep inelastic collisions or a very asymmetric fission of a compound system. This work will present experimental results obtained by the analysis of these experiments. We will show that heavy residues are formed with a production cross-section of 10 -2 mb. Angular distributions show that the residues can be produced by an incomplete fusion of the projectile and the target. The study of the products in coincidence with the residues shows that a compound system was formed, followed by a fission producing the residue and a lighter fragment. The comparison with a phenomenological model, HIPSE, confirms that the model is valid at these energies

  16. Projectile-like fragments from 129Xe+natCu reactions at E/A = 40 MeV

    International Nuclear Information System (INIS)

    Russ, D.E.; Mignerey, A.C.; Garcia-Solis, E.J.

    1996-01-01

    The bombarding of heavy nuclei with energetic heavy projectiles has been one of the most important experimental tools for nuclear science. At low beam energies, (E/A) beam 100 MeV, these mean field effects are less important and nucleon-nucleon interactions dominate. Within the intermediate energy region, the situation is less clear because of both the mean field and nucleon-nucleon effects contribute. There is no consensus on the theoretical treatment of nuclear reaction in the intermediate energy regime and statistical, dynamical, and hybrid models have been used with limited success. Previous studies of 136 Xe + 209 Bi at E/A = 28 MeV carried out at Michigan State University (MSU) have been well described by a damped reaction mechanism. On the other hand, 129 Xe + nat Cu at E/A = 50 MeV also at MSU has been compared with a hybrid model with reasonable success. In order to see a transition from a damped reaction mechanism to more fragmentation-like processes, an experiment was carried out at MSU using 129 Xe beams at E/A = 30, 40, 50, and 60 MeV. The targets were Cu, Sc, and Au. The current study only looks at the projectile-like fragments (PLF) detected in the Maryland Forward Array (MFA)

  17. Present status of the {sup 129}Xe comagnetometer development for neutron EDM measurement

    Energy Technology Data Exchange (ETDEWEB)

    Mihara, M., E-mail: mihara@vg.phys.sci.osaka-u.ac.jp [Osaka University, Department of Physics (Japan); Masuda, Y. [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK) (Japan); Matsuta, K. [Osaka University, Department of Physics (Japan); Kawasaki, S.; Watanabe, Y. [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK) (Japan); Hatanaka, K.; Matsumiya, R. [Osaka University, Research Center for Nuclear Physics (RCNP) (Japan)

    2016-12-15

    A {sup 129}Xe comagnetometer designed for the measurement of neutron electric dipole moment (nEDM) as precisely as 1 × 10{sup −27}e cm is presented. Highly nuclear spin polarized {sup 129}Xe are introduced into an EDM cell where the {sup 129}Xe spin precession is detected by means of the two-photon transition. The geometric phase effect (GPE) which generates the false nEDM was quantitatively discussed and the systematic error of nEDM from the GPE was estimated considering the buffer-gas suppression due to Xe atomic collisions. Research and development are in progress to construct the {sup 129}Xe comagnetometer with a field sensitivity of 0.3 fT. At present, about 70 % nuclear spin polarized {sup 129}Xe atoms have been obtained in a spin exchange opitial pumping cell, that are in the process of being transferred into the EDM cell via a cold trap.

  18. Ion mobilities in Xe/Ne and other rare-gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Piscitelli, D; Pitchford, L C [Centre de Physique des Plasmas et Applications de Toulouse (CPAT), UMR 5002 CNRS, 118 route de Narbonne, 31062 Toulouse (France); Phelps, A V [JILA, University of Colorado and National Institute of Technology, Boulder, Colorado (United States); Urquijo, J de [Centro de Ciencias Fisicas, Universidad Nacional Autonoma de Mexico, Post Office Box 48-3, 62251, 80309-0440 Cuernavaca, Moreno (Mexico); Basurto, E [Departmento de Ciencias Basicas, Universidad Autonoma Metropolitana, 02200 Mexico Distrito Federal (Mexico)

    2003-10-01

    The ion mobility or drift velocity data important for modeling glow discharges in rare gas mixtures are not generally available, nor are the ion-neutral scattering cross sections needed to calculate these data. In this paper we propose a set of cross sections for Xe{sup +} and Ne{sup +} collisions with Xe and Ne atoms. Ion mobilities at 300 K calculated using this cross section set in a Monte Carlo simulation are reported for reduced field strengths, E/N, up to 1500x10{sup -21} V m{sup 2}, in pure gases and in Xe/Ne mixtures containing 5% and 20% Xe/Ne, which are mixtures of interest for plasma display panels (PDPs). The calculated Xe{sup +} mobilities depend strongly on the mixture composition, but the Ne{sup +} mobility varies only slightly with increasing Xe in the mixture over the range studied here. The mobilities in pure gases compare well with available experimental values, and mobilities in gas mixtures at low E/N compare well with our recent measurements which will be published separately. Results from these calculations of ion mobilities are used to evaluate the predictions of Blanc's law and of the mixture rule proposed by Mason and Hahn [Phys. Rev. A 5, 438 (1972)] for determining the ion mobilities in mixtures from a knowledge of the mobilities in each of the pure gases. The mixture rule of Mason and Hahn is accurate to better than 10% at high field strengths over a wide range of conditions of interest for modeling PDPs. We conclude that a good estimate of ion mobilities at high E/N in Xe/Ne and other binary rare gas mixtures can be obtained using this mixture rule combined with known values of mobilities in parent gases and with the Langevin form for mobility of rare gas ions ion in other gases. This conclusion is supported by results in Ar/Ne mixtures which are also presented here.

  19. Identification of protein tyrosine phosphatase 1B and casein as substrates for 124-v-Mos

    Directory of Open Access Journals (Sweden)

    Stabel Silvia

    2002-04-01

    Full Text Available Abstract Background The mos proto-oncogene encodes a cytoplasmic serine/threonine-specific protein kinase with crucial function during meiotic cell division in vertebrates. Based on oncogenic amino acid substitutions the viral derivative, 124-v-Mos, displays constitutive protein kinase activity and functions independent of unknown upstream effectors of mos protein kinase. We have utilized this property of 124-v-Mos and screened for novel mos substrates in immunocomplex kinase assays in vitro. Results We generated recombinant 124-v-Mos using the baculovirus expression system in Spodoptera frugiperda cells and demonstrated constitutive kinase activity by the ability of 124-v-Mos to auto-phosphorylate and to phosphorylate vimentin, a known substrate of c-Mos. Using this approach we analyzed a panel of acidic and basic substrates in immunocomplex protein kinase assays and identified novel in vitro substrates for 124-v-Mos, the protein tyrosine phosphatase 1B (PTP1B, alpha-casein and beta-casein. We controlled mos-specific phosphorylation of PTP1B and casein in comparative assays using a synthetic kinase-inactive 124-v-Mos mutant and further, tryptic digests of mos-phosphorylated beta-casein identified a phosphopeptide specifically targeted by wild-type 124-v-Mos. Two-dimensional phosphoamino acid analyses showed that 124-v-mos targets serine and threonine residues for phosphorylation in casein at a 1:1 ratio but auto-phosphorylation occurs predominantly on serine residues. Conclusion The mos substrates identified in this study represent a basis to approach the identification of the mos-consensus phosphorylation motif, important for the development of specific inhibitors of the Mos protein kinase.

  20. Production of iodine-123 radiobiological specimen on 25 MeV electron beam

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.; Starodub, G.Ya.; Buklanov, G.V.; Korotkin, Yu.S.; Belov, A.G.

    1988-01-01

    The technique is described and experimental results are presented for production of radioactive specimen-iodine-123 for medical biological investigations. It is shown that in ten hour irradiation of 124 Xe enriched target of 10 g weight by the 25 MeV electron beam at MT-25 microtron short lived 123 I with activity of about 200 mCl can be accumulated. The procedure was developed for extraction of radioactive atoms and preparing the solution that permits to obtain during 1-1.5 h after the end of irradiation the specimen which satisfies all pharmacopeia requirements. It follows from the results that using small-size electron accelerators with the beam energy up to 25 MeV permits to organize economical and large-scale production of high quality radioactive specimen of 123 I for servicing a large region of this country. 14 refs.; 4 figs.; 1 tab

  1. Hyperpolarized 129Xe MRI: A viable functional lung imaging modality?

    International Nuclear Information System (INIS)

    Patz, Samuel; Hersman, F. William; Muradian, Iga; Hrovat, Mirko I.; Ruset, Iulian C.; Ketel, Stephen; Jacobson, Francine; Topulos, George P.; Hatabu, Hiroto; Butler, James P.

    2007-01-01

    The majority of researchers investigating hyperpolarized gas MRI as a candidate functional lung imaging modality have used 3 He as their imaging agent of choice rather than 129 Xe. This preference has been predominantly due to, 3 He providing stronger signals due to higher levels of polarization and higher gyromagnetic ratio, as well as its being easily available to more researchers due to availability of polarizers (USA) or ease of gas transport (Europe). Most researchers agree, however, that hyperpolarized 129 Xe will ultimately emerge as the imaging agent of choice due to its unlimited supply in nature and its falling cost. Our recent polarizer technology delivers vast improvements in hyperpolarized 129 Xe output. Using this polarizer, we have demonstrated the unique property of xenon to measure alveolar surface area noninvasively. In this article, we describe our human protocols and their safety, and our results for the measurement of the partial pressure of pulmonary oxygen (pO 2 ) by observation of 129 Xe signal decay. We note that the measurement of pO 2 by observation of 129 Xe signal decay is more complex than that for 3 He because of an additional signal loss mechanism due to interphase diffusion of 129 Xe from alveolar gas spaces to septal tissue. This results in measurements of an equivalent pO 2 that accounts for both traditional T 1 decay from pO 2 and that from interphase diffusion. We also provide an update on new technological advancements that form the foundation for an improved compact design polarizer as well as improvements that provide another order-of-magnitude scale-up in xenon polarizer output

  2. Direct Observation of Xe and Kr Adsorption in a Xe-Selective Microporous Metal-Organic Framework

    NARCIS (Netherlands)

    Chen, X.; Plonka, A.M.; Banerjee, D.; Krishna, R.; Schaef, H.T.; Ghose, S.; Thallapally, P.K.; Parise, J.B.

    2015-01-01

    The cryogenic separation of noble gases is energy-intensive and expensive, especially when low concentrations are involved. Metal organic frameworks (MOFs) containing polarizing groups within their pore spaces are predicted to be efficient Xe/Kr solid,state adsorbents, but no experimental insights

  3. Magnetic dipole strength in 128Xe and 134Xe in the spin-flip resonance region

    Science.gov (United States)

    Massarczyk, R.; Rusev, G.; Schwengner, R.; Dönau, F.; Bhatia, C.; Gooden, M. Â. E.; Kelley, J. Â. H.; Tonchev, A. Â. P.; Tornow, W.

    2014-11-01

    The magnetic dipole strength in the energy region of the spin-flip resonance is investigated in 128Xe and 134Xe using quasimonoenergetic and linearly polarized γ -ray beams at the High-Intensity γ -Ray Source facility in Durham, North Carolina, USA. Absorption cross sections were deduced for the magnetic and electric and dipole strength distributions separately for various intervals of excitation energy, including the strength of states in the unresolved quasicontinuum. The magnetic dipole strength distributions show structures resembling a resonance in the spin-flip region around an excitation energy of 8 MeV. The electric dipole strength distributions obtained from the present experiments are in agreement with the ones deduced from an earlier experiment using broad-band bremsstrahlung instead of a quasimonoenergetic beam. The experimental magnetic and electric dipole strength distributions are compared with phenomenological approximations and with predictions of a quasiparticle random phase approximation in a deformed basis.

  4. Noble gas bond and the behaviour of XeO3 under pressure.

    Science.gov (United States)

    Hou, Chunju; Wang, Xianlong; Botana, Jorge; Miao, Maosheng

    2017-10-18

    Over the past few decades, the concept of hydrogen bonds, in which hydrogen is electrophilic, has been extended to halogen bonds, chalcogen bonds and pnicogen bonds. Herein, we show that such a non-covalent bonding also exists in noble gas compounds. Using first principles calculations, we illustrate the OXe-O bond in molecular crystal XeO 3 and its effect on the behavior of this compound under pressure. Our calculations show that the covalent Xe-O bond lengths were elongated with increasing pressure and correspondingly the Xe-O stretching vibration frequencies were red shifted, which is similar to the change of H-bonds under pressure. The OXe-O bond and related hopping of O between neighboring Xe sites also correspond to the structural changes in the XeO 3 compounds at about 2 GPa. Our study extends the concept of hydrogen bonding to include all p-block elements and show a new bonding type for Noble gas elements in which it acts as an electrophilic species.

  5. Neutron-induced Backgrounds in 134Xe for Large-Scale Neutrinoless Double-Beta Decay Experiments

    Science.gov (United States)

    Moriguchi, Nina; Kidd, Mary; Tornow, Werner

    2016-09-01

    136Xe is used in large neutrinoless double-beta (0 νββ) decay experiments, such as KamLAND- Zen and EXO 200. Though highly purified, 136Xe still contains a significant amount of 134Xe. Recently, a new nuclear energy level was found in 134Xe. If 134Xe decays from this proposed excited state, it will emit a 2485.7 keV gamma ray. Because this energy lies near the region of interest of 136Xe νββ decay experiments (Q value 2457.8 keV), it could make a significant contribution to the background. A purified gaseous sample of 134Xe will be irradiated with neutrons of an incident energy of 4.0 MeV at Triangle Universities Nuclear Laboratory and monitored with high-purity germanium detectors. The spectra obtained from these detectors will be analyzed for the presence of the 2581 keV gamma ray. We will report on the status of this experiment. Future plans include expanding this measurement to higher initial neutron energies. Tennesse Tech University CISE Grant program.

  6. Sputtering of Au induced by single Xe ion impacts

    International Nuclear Information System (INIS)

    Birtcher, R. C.; Donnelly, S. E.

    1999-01-01

    Sputtering of Au thin films has been determined for Xe ions with energies between 50 and 600 keV. In-situ transmission electron microscopy was used to observe sputtered Au during deposition on a carbon foil near the specimen. Total reflection and transmission sputtering yields for a 62 nm thick Au thin film were determined by ex-situ measurement of the total amount of Au on the carbon foils. In situ observations show that individual Xe ions eject Au nanoparticles as large as 7 nm in diameter with an average diameter of approximately 3 nm. Particle emission correlates with crater formation due to single ion impacts. Nanoparticle emission contributes significantly to the total sputtering yield for Xe ions in this energy range in either reflection or transmission geometry

  7. A high volume, batch mode {sup 129}Xe polarizer

    Energy Technology Data Exchange (ETDEWEB)

    Wojna-Pelczar, Anna, E-mail: anna.wojna.pelczar@mail.muni.cz [Central European Institute of Technology, Masaryk University, Brno (Czech Republic); Formerly: Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków (Poland); Pałasz, Tadeusz [Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków (Poland)

    2017-06-01

    Numerous designs of optical gas polarizers have been proposed, broadening possible applications of the hyperpolarized gases as contrast agents in magnetic resonance imaging. We present a home–made {sup 129}Xe polarizer based on the spin exchange optical pumping method. The polarizer operates under 1 bar of the gas mixture (at the maximum temperature of 160 °C) in a high volume optical cell (5025 cm{sup 3}). Approximately 100 cm{sup 3} of {sup 129}Xe polarized at 1.50±0.37% is produced in a single cycle of polarization. Operation under standard pressure imposes polarization transfer mainly via van der Waals molecules, resulting in the efficient spin exchange between rubidium and {sup 129}Xe atoms. The design, construction and operation of the polarizer are described in details.

  8. Nuclear fragmentation for Xe+Au and Xe+Ag systems at an energy of 44 A.MeV, formation and decay of hot nuclei; Etude de la fragmentation nucleaire pour les systemes XE+AU et XE+AG a 44 A.MeV, production et decroissance de noyaux chauds

    Energy Technology Data Exchange (ETDEWEB)

    Meslin, C.

    1995-01-01

    A study of the formation and the decay of hot nuclear fragments produced in the reactions Xe+Au and Xe+Ag at an energy of 44 A.MeV is presented in this thesis. The 4{pi} experimental setup consisted of four multidetectors -two for the detection of the fragments (Z>7; DELF and XYZT) and two for the detection of the charged particles (Z<6; MUR and TONNEAU) and allowed an analysis using ``complete events`` (80 % of the total charge and the total parallel linear momentum of the entrance channel) to be carried out. The reaction mechanism is binary with as observed at low energy an almost complete relaxation of the incident energy. The collision results in two hot fragments at the beginning of the exit channel which decay by evaporation and/or fragmentation. In addition of these two body events, we have identified a new dynamic mechanism where we detect a small fragment, called the neck, coming form the overlap of the nuclei during the interaction, in coincidence with a projectile-like fragment and a target-like fragment. For the most dissipative collisions, the deep inelastic collision have allowed an estimation of the lifetime of the hot nuclear fragments to be made. This is possible using proximity effects and fragment-fragment space-time correlations of the decay of one or two primary partners from the deep inelastic collisions. This method is seen to reach its limits in the case of the reactions studied here. (authors). 61 refs.

  9. Angle Performance on Optima XE

    International Nuclear Information System (INIS)

    David, Jonathan; Satoh, Shu

    2011-01-01

    Angle control on high energy implanters is important due to shrinking device dimensions, and sensitivity to channeling at high beam energies. On Optima XE, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through a series of narrow slits, and any angle adjustment is made by steering the beam with the corrector magnet. In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen during implant.Using a sensitive channeling condition, we were able to quantify the angle repeatability of Optima XE. By quantifying the sheet resistance sensitivity to both horizontal and vertical angle variation, the total angle variation was calculated as 0.04 deg. (1σ). Implants were run over a five week period, with all of the wafers selected from a single boule, in order to control for any crystal cut variation.

  10. Solution-based targeted genomic enrichment for precious DNA samples

    Directory of Open Access Journals (Sweden)

    Shearer Aiden

    2012-05-01

    Full Text Available Abstract Background Solution-based targeted genomic enrichment (TGE protocols permit selective sequencing of genomic regions of interest on a massively parallel scale. These protocols could be improved by: 1 modifying or eliminating time consuming steps; 2 increasing yield to reduce input DNA and excessive PCR cycling; and 3 enhancing reproducible. Results We developed a solution-based TGE method for downstream Illumina sequencing in a non-automated workflow, adding standard Illumina barcode indexes during the post-hybridization amplification to allow for sample pooling prior to sequencing. The method utilizes Agilent SureSelect baits, primers and hybridization reagents for the capture, off-the-shelf reagents for the library preparation steps, and adaptor oligonucleotides for Illumina paired-end sequencing purchased directly from an oligonucleotide manufacturing company. Conclusions This solution-based TGE method for Illumina sequencing is optimized for small- or medium-sized laboratories and addresses the weaknesses of standard protocols by reducing the amount of input DNA required, increasing capture yield, optimizing efficiency, and improving reproducibility.

  11. Microbulk MicrOMEGAs for the search of 0νββ of 136Xe in the PandaX-III experiment

    International Nuclear Information System (INIS)

    Galan, J.

    2016-01-01

    The search for the neutrinoless double beta decay (0νββ) is one of the most important quests nowadays in neutrino physics. Among the different techniques used, high pressure xenon (HPXe) gas time projection chambers (TPC) stand out because they allow to image the topology of the 0νββ event (one straggling track ending in two blobs), and use it to discriminate signal from background events. Recent results with microbulk Micromegas in Xe + trimethylamine (TMA) mixtures show high promise in terms of gain, stability of operation, and energy resolution at high pressures (up to 10 bar). The addition of TMA at levels of 1% reduces electron diffusion in up to a factor of 10 with respect pure Xe, improving the quality of the topological pattern, and therefore the discrimination capability. Moreover microbulk Micromegas have very low levels of intrinsic radioactivity. All these results show that a Micromegas-read High Pressure Xenon TPC (HPXe-TPC) can be a competitive technique in the search for 0νββ. The recently proposed PandaX-III experiment, based on these results, aims at building a large TPC of 200 kg of enriched Xe, to be located at Jinping Underground laboratory in China. In this document the main features of the experiment will be presented, with an emphasis on the design and tests of the microbulk readout, as well as the status of the project and first results of the prototyping phase.

  12. Detection of interstellar DNC - Difficulties of chemical equilibrium hypothesis for enrichment

    Science.gov (United States)

    Godfrey, P. D.; Brown, R. D.; Gunn, H. I.; Blackman, G. L.; Storey, J. W. V.

    1977-01-01

    The J = 1-0 transition of DNC at 76.3058 GHz has been observed in emission in NGC 2264. Comparison with previous observations of HN(C-13) indicates that deuterium is enriched in DNC similarly to the enrichment reported for DCO(+) in this source. The DNC/HNC ratio is estimated to be about 1/24. The results cannot readily be interpreted in terms of chemical equilibria relating to the formation of DNC. It is suggested that the explanation must be sought in isotope effects on rates of formation of interstellar molecules.

  13. High Biofilm Conductivity Maintained Despite Anode Potential Changes in a Geobacter-Enriched Biofilm

    Science.gov (United States)

    This study systematically assessed intracellular electron transfer (IET) and extracellular electron transfer (EET) kinetics with respect to anode potential (Eanode) in a mixed-culture biofilm anode enriched with Geobacter spp. High biofilm conductivity (0.96–1.24 mScm^-1) was mai...

  14. Study of high-j neutron excitations outside 136Xe

    Science.gov (United States)

    Talwar, R.; Kay, B. P.; Mitchell, A. J.; Adachi, S.; Entwisle, J. P.; Fujita, Y.; Gey, G.; Noji, S.; Ong, H. J.; Schiffer, J. P.; Tamii, A.

    2017-09-01

    The character of single-neutron excitations outside of N = 82 has been studied using nucleon transfer reactions in terms of the energy centroid of their strength as well as the fragmentation of this strength among the actual states of the nucleus. However, extending the systematic study of the N = 83 isotones to 137Xe has been challenging due to xenon being a gas at room temperature. Though several attempts have been made, a quantitative determination of the spectroscopic factors for the neutron 9/2- and 13/2+ excitations in 137Xe is still lacking. In the present work, we report on a study of the 136Xe(α,3He)137Xe reaction carried out at 100 MeV to probe the l = 5 , 9/2- and l = 6 , 13/2+ single-neutron excitations. The experimental technique and results will be presented discussing them in context of the evolution of these single-neutron excitations and the influence of the tensor interaction on the neutron single-particle states as the proton orbits are filling. This work has been supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Contract Number DE-AC02-06CH11357, the Australian Research Council Discovery Project 120104176, and the UK Science and Technology Facilities.

  15. Zeolitic Imidazolate Framework-8 (ZIF-8) Membranes for Kr/Xe Separation

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ting; Feng, Xuhui; Elsaidi, Sameh K.; Thallapally, Praveen K.; Carreon, Moises A.

    2017-01-30

    Herein, we demonstrate that a prototypical type of metal organic framework, zeolitic imidazolate framework-8 (ZIF-8), in membrane form, can effectively separate Kr/Xe gas mixtures at industrially relevant compositions. The best membranes separated Kr/Xe mixtures with average Kr permeances as high as 1.5 × 10-8 ± 0.2 mol/m2 s Pa and average separation selectivities of 14.2 ± 1.9 for molar feed compositions corresponding to Kr/Xe ratio encountered typically in air. Molecular sieving, competitive adsorption, and differences in diffusivities were identified as the prevailing separation mechanisms. These membranes potentially represent a less-energy-intensive alternative to cryogenic distillation, which is the benchmark technology used to separate this challenging gas mixture. To our best knowledge, this is the first example of any metal organic membrane composition displaying separation ability for Kr/Xe gas mixtures.

  16. Experimental ion mobility measurements in Xe-CO2

    Science.gov (United States)

    Cortez, A. F. V.; Santos, M. A. G.; Veenhof, R.; Patra, R. N.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2017-06-01

    Data on ion mobility is important to improve the performance of large volume gaseous detectors. In the present work the method, experimental setup and results for the ion mobility measurements in Xe-CO2 mixtures are presented. The results for this mixture show the presence of only one peak for all gas ratios of Xe-CO2, low reduced electric fields, E/N, 10-25 Td (2.4-6.1 kV·cm-1·bar-1), low pressures 6-8 Torr (8-10.6 mbar), at room temperature.

  17. Disintegration of C60 by Xe ion irradiation

    International Nuclear Information System (INIS)

    Kalish, R.; Samoiloff, A.; Hoffman, A.; Uzan-Saguy, C.

    1993-01-01

    The Changes in resistivity of fullerene (C 60 ) films subject to 320 keV Xe ion irradiation are investigated as a function of ion dose. From a comparison of this dependence with similar data on other Xe irradiated C containing insulating materials and with data on C implanted fused quartz, it is concluded that upon ion impact C 60 clusters completely disintegrate. This disintegration releases about 60 C atoms which disperse amongst the remaining intact C 60 spheres giving rise to hopping conductivity between isolated C atoms. 16 refs., 3 figs

  18. Statistical inference on censored data for targeted clinical trials under enrichment design.

    Science.gov (United States)

    Chen, Chen-Fang; Lin, Jr-Rung; Liu, Jen-Pei

    2013-01-01

    For the traditional clinical trials, inclusion and exclusion criteria are usually based on some clinical endpoints; the genetic or genomic variability of the trial participants are not totally utilized in the criteria. After completion of the human genome project, the disease targets at the molecular level can be identified and can be utilized for the treatment of diseases. However, the accuracy of diagnostic devices for identification of such molecular targets is usually not perfect. Some of the patients enrolled in targeted clinical trials with a positive result for the molecular target might not have the specific molecular targets. As a result, the treatment effect may be underestimated in the patient population truly with the molecular target. To resolve this issue, under the exponential distribution, we develop inferential procedures for the treatment effects of the targeted drug based on the censored endpoints in the patients truly with the molecular targets. Under an enrichment design, we propose using the expectation-maximization algorithm in conjunction with the bootstrap technique to incorporate the inaccuracy of the diagnostic device for detection of the molecular targets on the inference of the treatment effects. A simulation study was conducted to empirically investigate the performance of the proposed methods. Simulation results demonstrate that under the exponential distribution, the proposed estimator is nearly unbiased with adequate precision, and the confidence interval can provide adequate coverage probability. In addition, the proposed testing procedure can adequately control the size with sufficient power. On the other hand, when the proportional hazard assumption is violated, additional simulation studies show that the type I error rate is not controlled at the nominal level and is an increasing function of the positive predictive value. A numerical example illustrates the proposed procedures. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Trampoline motions in Xe-graphite(0 0 0 1) surface scattering

    Science.gov (United States)

    Watanabe, Yoshimasa; Yamaguchi, Hiroki; Hashinokuchi, Michihiro; Sawabe, Kyoichi; Maruyama, Shigeo; Matsumoto, Yoichiro; Shobatake, Kosuke

    2005-09-01

    We have investigated Xe scattering from the graphite(0 0 0 1) surface at hyperthermal incident energies using a molecular beam-surface scattering technique and molecular dynamics simulations. For all incident conditions, the incident Xe atom conserves the momentum parallel to the surface and loses approximately 80% of the normal incident energy. The weak interlayer potential of graphite disperses the deformation over the wide range of a graphene sheet. The dynamic corrugation induced by the collision is smooth even at hyperthermal incident energy; the graphene sheet moves like a trampoline net and the Xe atom like a trampoliner.

  20. Programming A Molecular Relay for Ultrasensitive Biodetection through 129 Xe NMR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yanfei [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA; Roose, Benjamin W. [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA; Philbin, John P. [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA; Doman, Jordan L. [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA; Dmochowski, Ivan J. [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA

    2015-12-21

    We reported a supramolecular strategy for detecting specific proteins in complex media by using hyperpolarized 129Xe NMR. A cucurbit[6]uril (CB[6])-based molecular relay was programmed for three sequential equilibrium conditions by designing a two-faced guest (TFG) that initially binds CB[6] and blocks the CB[6]–Xe interaction. Moreover, the protein analyte recruits the TFG and frees CB[6] for Xe binding. TFGs containing CB[6]- and carbonic anhydrase II (CAII)-binding domains were synthesized in one or two steps. X-ray crystallography confirmed TFG binding to Zn2+ in the deep CAII active-site cleft, which precludes simultaneous CB[6] binding. The molecular relay was reprogrammed to detect avidin by using a different TFG. Finally, Xe binding by CB[6] was detected in buffer and in E. coli cultures expressing CAII through ultrasensitive 129Xe NMR spectroscopy.

  1. XeCl Excimer Laser For Micro - Machining Of Materials: Preliminary Theoretical And Experimental Works.

    Science.gov (United States)

    Iwanejko, Leszek; Pokora, Ludwik; Stefanski, Miroslaw; Ujda, Zbigniew

    1987-10-01

    The paper presents the results of preliminary investigations, both theoretical and experimental, of XeC1 excimer laser pumped by transverse electric discharge with UU preionization. The medium was a mixture of gases He-Xe-HC1. A theoretical model of the XeC1 laser was worked out and a lot of laser parameters calculations were done. In the same time an excimer laser operating on the mixture He-Xe-HC1 was started, the generation of laser radiation was of energy about 20mJ.

  2. Gain measurements of the Ca-Xe charge exchange system. [for UV lasers

    Science.gov (United States)

    Michels, C. J.; Chubb, D. L.

    1978-01-01

    Charge-exchange-pumped Ca(+) was studied for possible positive laser gain at 370.6 and 315.9 nm using an Xe MPD arc as the Xe(+) source. The present paper describes the MPD arc, the calcium injection system, the diagnostics for gain, and spontaneous emission measurements and results. No positive gain measurements were observed. A small Xe-Ca charge exchange cross section compared to He-metal laser systems charge exchange cross sections is the most probable reason why the result was negative.

  3. New study on the XeVIII spectrum

    International Nuclear Information System (INIS)

    Gallardo, M.; Raineri, M.; Giuliani, M.; Lagorio, C.; Padilla, S.; Sarmiento, R.; Reyna Almandos, J.G.

    2005-01-01

    Capillary light sources were used to observe the spectrum of seven-times-ionized xenon, XeVIII, in the 300-6000 A wavelength range. Twenty-eight energy levels belonging to the 5s-9s, 5d-9d, 5g-9g, 7i-10i, 9l, 5p-9p, 4f-9f, 6h-9h and 8k-10k configurations were adjusted and 38 new spectral lines were classified. The XeVIII ionization energy was determined with improved accuracy using the polarization model. The analysis was supported by Hartree-Fock calculations. The weighted oscillator strengths for all the observed spectral lines were also calculated considering the fitted values for the energy parameters

  4. New study on the XeVIII spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, M. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: gallardom@ciop.unlp.edu.ar; Raineri, M. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: monicar@ciop.unlp.edu.ar; Giuliani, M. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Lagorio, C. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Padilla, S. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Sarmiento, R. [Dto. De Fisica, Universidad del Atlantico, A.A 1890 Barranquilla (Colombia); Reyna Almandos, J.G. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: jreyna@ciop.unlp.edu.ar

    2005-10-15

    Capillary light sources were used to observe the spectrum of seven-times-ionized xenon, XeVIII, in the 300-6000 A wavelength range. Twenty-eight energy levels belonging to the 5s-9s, 5d-9d, 5g-9g, 7i-10i, 9l, 5p-9p, 4f-9f, 6h-9h and 8k-10k configurations were adjusted and 38 new spectral lines were classified. The XeVIII ionization energy was determined with improved accuracy using the polarization model. The analysis was supported by Hartree-Fock calculations. The weighted oscillator strengths for all the observed spectral lines were also calculated considering the fitted values for the energy parameters.

  5. 18 CFR 401.124 - Construction.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Construction. 401.124 Section 401.124 Conservation of Power and Water Resources DELAWARE RIVER BASIN COMMISSION ADMINISTRATIVE MANUAL RULES OF PRACTICE AND PROCEDURE General Provisions § 401.124 Construction. This part is...

  6. L-shell X-ray production of molybdenum and niobium induced by 1500–3500 keV Xe26+ ions

    International Nuclear Information System (INIS)

    Guo, Yipan; Yang, Zhihu; Song, Zhangyong; Xu, Qiumei; Chen, Jing; Yang, Bian

    2013-01-01

    L-shell X-ray production cross sections are measured for molybdenum and niobium target induced by Xe 26+ ions. The incident energy range varies from 1500 to 3500 keV. The experimental results are well reproduced by the binding-energy-modified binary encounter approximation model in the united-atom limit. In addition to target L-shell X-ray spectra, we also observe a weak spectrum which corresponds to the forbidden transition 3d → 2s from the projectiles

  7. MicroRNA-124 controls the proliferative, migratory, and inflammatory phenotype of pulmonary vascular fibroblasts.

    Science.gov (United States)

    Wang, Daren; Zhang, Hui; Li, Min; Frid, Maria G; Flockton, Amanda R; McKeon, B Alexandre; Yeager, Michael E; Fini, Mehdi A; Morrell, Nicholas W; Pullamsetti, Soni S; Velegala, Sivareddy; Seeger, Werner; McKinsey, Timothy A; Sucharov, Carmen C; Stenmark, Kurt R

    2014-01-03

    Pulmonary hypertensive remodeling is characterized by excessive proliferation, migration, and proinflammatory activation of adventitial fibroblasts. In culture, fibroblasts maintain a similar activated phenotype. The mechanisms responsible for generation/maintenance of this phenotype remain unknown. We hypothesized that aberrant expression of microRNA-124 (miR-124) regulates this activated fibroblast phenotype and sought to determine the signaling pathways through which miR-124 exerts effects. We detected significant decreases in miR-124 expression in fibroblasts isolated from calves and humans with severe pulmonary hypertension. Overexpression of miR-124 by mimic transfection significantly attenuated proliferation, migration, and monocyte chemotactic protein-1 expression of hypertensive fibroblasts, whereas anti-miR-124 treatment of control fibroblasts resulted in their increased proliferation, migration, and monocyte chemotactic protein-1 expression. Furthermore, the alternative splicing factor, polypyrimidine tract-binding protein 1, was shown to be a direct target of miR-124 and to be upregulated both in vivo and in vitro in bovine and human pulmonary hypertensive fibroblasts. The effects of miR-124 on fibroblast proliferation were mediated via direct binding to the 3' untranslated region of polypyrimidine tract-binding protein 1 and subsequent regulation of Notch1/phosphatase and tensin homolog/FOXO3/p21Cip1 and p27Kip1 signaling. We showed that miR-124 directly regulates monocyte chemotactic protein-1 expression in pulmonary hypertension/idiopathic pulmonary arterial hypertension fibroblasts. Furthermore, we demonstrated that miR-124 expression is suppressed by histone deacetylases and that treatment of hypertensive fibroblasts with histone deacetylase inhibitors increased miR-124 expression and decreased proliferation and monocyte chemotactic protein-1 production. Stable decreases in miR-124 expression contribute to an epigenetically reprogrammed, highly

  8. Search for the permanent electric dipole moment of 129Xe

    Science.gov (United States)

    Sachdeva, Natasha; Chupp, Timothy; Gong, Fei; Babcock, Earl; Salhi, Zahir; Burghoff, Martin; Fan, Isaac; Killian, Wolfgang; Knappe-Grüneberg, Silvia; Schabel, Allard; Seifert, Frank; Trahms, Lutz; Voigt, Jens; Degenkolb, Skyler; Fierlinger, Peter; Krägeloh, Eva; Lins, Tobias; Marino, Michael; Meinel, Jonas; Niessen, Benjamin; Stuiber, Stefan; Terrano, William; Kuchler, Florian; Singh, Jaideep

    2017-09-01

    CP-violation in Beyond-the-Standard-Model physics, necessary to explain the baryon asymmetry, gives rise to permanent electric dipole moments (EDMs). EDM measurements of the neutron, electron, paramagnetic and diamagnetic atoms constrain CP-violating parameters. The current limit for the 129Xe EDM is 6 ×10-27 e . cm (95 % CL). The HeXeEDM experiment at FRM-II (Munich Research Reactor) and BMSR-2 (Berlin Magnetically Shielded Room) uses a stable magnetic field in a magnetically shielded room and 3He comagnetometer with potential to improve the limit by two orders of magnitude. Polarized 3He and 129Xe free precession is detected with SQUID magnetometers in the presence of applied electric and magnetic fields. Conclusions from recent measurements will be presented.

  9. Measurement of
 the azimuthal anisotropy of charged particles 
in 5.02 TeV Pb+Pb and 5.44 TeV Xe+Xe collisions 
with ATLAS

    CERN Document Server

    Bold, Tomasz; The ATLAS collaboration

    2018-01-01

    The experimental data collected by the ATLAS experiment during the 2015 Pb+Pb and 2017 Xe+Xe LHC runs offer new opportunities to study charged particle azimuthal anisotropy. The high-statistics Pb+Pb sample allows for a detailed study of the azimuthal anisotropy of produced particles. This should improve the understanding of initial conditions of nuclear collisions, hydrodynamical behavior of quark-gluon plasma and parton energy loss. New ATLAS measurements of differential and global Fourier harmonics of charged particles (vn) in 5.02 TeV Pb+Pb and 5.44 TeV Xe+Xe collisions in a wide range of transverse momenta, pseudorapidity (|η|<2.5) and collision centrality are presented. The higher order harmonics, sensitive to fluctuations in the initial state, are measured up to n=7 using the two-particle correlation, cumulant and scalar product methods. The dynamic properties of QGP are studied using a recently-proposed modified Pearson's correlation coefficient, ρ(v2n,pT), between the eventwise mean transverse m...

  10. Laser generation of XeCl exciplex molecules in a longitudinal repetitively pulsed discharge in a Xe - CsCl mixture

    Science.gov (United States)

    Boichenko, A. M.; Klenovskii, M. S.

    2015-12-01

    By using the previously developed kinetic model, we have carried out simulations to study the possibility of laser generation of XeCl exciplex molecules in the working medium based on a mixture of Xe with CsCl vapours, excited by a longitudinal repetitively pulsed discharge. The formation mechanism of exciplex molecules in this mixture is fundamentally different from the formation mechanisms in the traditional mixtures of exciplex lasers. The conditions that make the laser generation possible are discussed. For these conditions, with allowance for available specific experimental conditions of the repetitively pulsed discharge excitation, we have obtained the calculated dependences of the power and efficiency of generation on the reflectivity of mirrors in a laser cavity.

  11. 7 CFR 1221.124 - Reports.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Reports. 1221.124 Section 1221.124 Agriculture... INFORMATION ORDER Sorghum Promotion, Research, and Information Order Reports, Books, and Records § 1221.124 Reports. (a) Each first handler, on a State-by-State basis, will be required to provide to the Board...

  12. Magnetic dipole strength in {sup 128}Xe and {sup 134}Xe in the spin-flip resonance region

    Energy Technology Data Exchange (ETDEWEB)

    Massarczyk, R. [Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden (Germany); Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Rusev, G. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Schwengner, R.; Doenau, F. [Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden (Germany); Bathia, C. [McMaster University, Hamilton, Ontario L8S4L8 (Canada); Gooden, M.E.; Kelley, J.H. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); North Carolina State University, Raleigh, NC 27695 (United States); Tonchev, A.P. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Tornow, W. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Duke University, Durham, NC 27708 (United States)

    2015-07-01

    The magnetic dipole strength in the energy region of the spin-flip resonance is investigated in {sup 128}Xe and {sup 134}Xe using quasimonoenergetic and linearly polarized γ-ray beams at the High-Intensity γ-Ray Source facility in Durham, North Carolina, USA. Absorption cross sections were deduced for the magnetic and electric and dipole strength distributions separately for various intervals of excitation energy, including the strength of states in the unresolved quasicontinuum. The magnetic dipole strength distributions show structures resembling a resonance in the spin-flip region around an excitation energy of 8 MeV. The electric dipole strength distributions obtained from the present experiments are in agreement with the ones deduced from an earlier experiment using broad-band bremsstrahlung instead of a quasimonoenergetic beam. The experimental magnetic and electric dipole strength distributions are compared with model predictions.

  13. Negative heat capacities in central Xe+Sn reactions

    International Nuclear Information System (INIS)

    Le Neindre, N.; Bougault, R.; Gulminelli, F.

    2000-02-01

    In this study the fluctuation method is applied to the 32-50 A.MeV Xe + Sn central collisions detected with the INDRA multidetector. This method based on kinetic energy fluctuations allows the authors to provide information on the liquid gas phase transition in nuclear multifragmentation. In the case of Xe + Sn central reactions a divergence in the total heat capacity is observed. This divergence corresponds to large fluctuations on the detected fragment partitions. A negative heat capacity branch is measured and so tends to confirm the observation of a first order phase transition in heavy-ion collisions. (A.C.)

  14. New 1,2,4-triazine bearing compounds: molecular modeling, synthesis and biotesting

    Directory of Open Access Journals (Sweden)

    Negrutska V. V.

    2009-12-01

    Full Text Available Aim. To enlarge a spectrum of biologically active compounds in the series of the 1,2,4-triazino[5,6-b] [1,4]benzothiazine (1,2,4-TBT derivatives and reveal among them efficient inhibitors of RNA synthesis Methods. The methods of structure optimization of the 3-oxo-1,2,4-TBT by fragment-oriented substitution, the molecular doking of new structures in a virtual target, the rational chemical synthesis of the theoretically predicted compounds and their testing in the system of transcription in vitro. Results. The series of 1,2,4-TBT derivatives with substituents in the benzene and triazine cycles of a base molecule were synthesized. The testing of synthesized compounds in the in vitro transcription system directed by T7 RNA polymerase revealed the structure- and concentration-dependent inhibition of the RNA synthesis by some of these compounds. The experimental and virtual screening data for all investigated compounds have a good correlation. It was found that most effective derivative is the 3-oxo-8-butyl-1,2,4-TBT which completely inhibited transcription at the concentration of 6 mg/ml. Conclusions. The biotesting results allow us to assume that the inhibition of RNA synthesis is caused by binding of the 3-oxo- 8-butyl-1,2,4-TBT to both free RNA polymerase molecules and those including in a transcriptional complex with DNA

  15. Comparison of 133Xe gas dynamic SPECT and thin-section CT in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    2001-01-01

    We assessed 133 Xe gas dynamic single photon emission computed tomography (SPECT) by comparing washout axial images with thin-section CT (TSCT) in patients with pulmonary emphysema. Twenty-three patients were studied. All patients were diagnosed as having pulmonary emphysema on the basis of TSCT. We compared TSCT of upper, middle and lower lung fields with 133 Xe gas dynamic SPECT axial images at the corresponding levels during the 3 to 4 minutes of washout phase. If the degree of 133 Xe gas retention or TSCT finding of ventral and dorsal parts was not the same, the images were divided into two parts. A total of 174 lesions in 23 cases were examined, but 3 lesions having no retention of 133 Xe gas at equilibrium phase were excluded. The results showed that: there were 37 lesions (21.6%) with equivalent severity on both images; there were 42 lesions (24.5%) with more severity on 133 Xe gas dynamic SPECT than on TSCT; and there were 92 lesions (53.8%) with more severity on TSCT than on 133 Xe gas dynamic SPECT. The severity on 133 Xe gas dynamic SPECT and TSCT was not always compatible. One of the reasons for the variable 133 Xe gas retention even when the lesion had the same severity on TSCT, may be bronchial stricture which cannot be seen on TSCT. By comparison of axial images of 133 Xe gas dynamic SPECT with CT images, we could recognize the areas of 133 Xe gas retention in detail. Results suggest that 133 Xe gas dynamic SPECT can be useful to identify ventilation impairment in pulmonary emphysema. (author)

  16. The development and progress of XeCl Excimer laser system

    Science.gov (United States)

    Zhang, Yongsheng; Ma, Lianying; Wang, Dahui; Zhao, Xueqing; Zhu, Yongxiang; Hu, Yun; Qian, Hang; Shao, Bibo; Yi, Aiping; Liu, Jingru

    2015-05-01

    A large angularly multiplexed XeCl Excimer laser system is under development at the Northwest Institute of Nuclear Technology (NINT). It is designed to explore the technical issues of uniform and controllable target illumination. Short wavelength, uniform and controllable target illumination is the fundamental requirement of high energy density physics research using large laser facility. With broadband, extended light source and multi-beam overlapping techniques, rare gas halide Excimer laser facility will provide uniform target illumination theoretically. Angular multiplexing and image relay techniques are briefly reviewed and some of the limitations are examined to put it more practical. The system consists of a commercial oscillator front end, three gas discharge amplifiers, two electron beam pumped amplifiers and the optics required to relay, encode and decode the laser beam. An 18 lens array targeting optics direct and focus the laser in the vacuum target chamber. The system is operational and currently undergoing tests. The total 18 beams output energy is more than 100J and the pulse width is 7ns (FWHM), the intensities on the target will exceed 1013W/cm2. The aberration of off-axis imaging optics at main amplifier should be minimized to improve the final image quality at the target. Automatic computer controlled alignment of the whole system is vital to efficiency and stability of the laser system, an array of automatic alignment model is under test and will be incorporated in the system soon.

  17. 24 CFR 884.124 - Audit.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Audit. 884.124 Section 884.124... HOUSING PROJECTS Applicability, Scope and Basic Policies § 884.124 Audit. (a) Where a State or local..., receiving financial assistance under this part, the audit requirements in 24 CFR part 44 shall apply. (b...

  18. 24 CFR 882.124 - Audit.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Audit. 882.124 Section 882.124...) SECTION 8 MODERATE REHABILITATION PROGRAMS Applicability, Scope and Basic Policies § 882.124 Audit. PHAs receiving financial assistance under this part are subject to audit requirements in 24 CFR part 44. [50 FR...

  19. Level structure in 123Xe

    International Nuclear Information System (INIS)

    Luukko, A.; Hattula, J.; Helppi, H.; Knuuttila, O.

    1980-09-01

    The level structure of 123 Xe has been studied with 122 Te( 3 He,2n) and 123 Te( 3 He,3n) reactions using in-beam γ-ray spectroscopic methods. Band-like level structures based on the unique-parity hsub(11/2) neutron state and different low-j states are observed. The isomeric state proposed earlier is established at 185.4 keV with a half-life of 5.6+-0.3 μs, and a new spin assignment of 7/2 - is proposed for this level. A triaxial-rotor-model calculation has been performed to interprete the negative-parity level system. Because of the 7/2 - state, we do not obtain a consistent description of the negative-parity states with the triaxial rotor model, unlike the heavier odd-A Xe nuclei. On the other hand, the positive-parity level structures are interpreted in terms of the core-quasiparticle model supposing a vibrational core. This indicates different core shapes for the positive- and negative-parity level systems. (author)

  20. Structure of intruder band in "1"1"9"-"1"2"9Xe

    International Nuclear Information System (INIS)

    Sharma, H.P.; Chakraborty, S.; Tiwary, S.S.

    2017-01-01

    Xe isotopes in A∼130 mass region are known for their variety of structural phenomena, such as, unexpected signature splitting, signature inversion, γ-vibration etc. These phenomena are associated to axialy asymmetric shape. The triaxial shape in Xe nuclei are expected to originate due to the availability of prolate driving low-Ω πh_1_1_/_2 orbital and oblate driving high-Ω νh11/2 orbital near Fermi surface. The observed experimental E (4"+)/E (2"+) value (∼2.5) also support the γ-soft nature of these nuclei. Interestingly, both proton and neutron alignments have been observed in νh_1_1_/_2 band in "1"1"9"-"1"2"5Xe and neutron alignment dominates. In "1"2"9Xe, proton alignment reported to dominate. It is also supported by TPRM calculations, although, there are no significant change in the neutron orbitals. Whether this change in the alignment is occurred at N=75 or 73 is not known. Therefore, it is interesting to understand the status of the neutron and proton alignment in "1"2"7Xe, which are not studied well. Hence, in-beam γ-ray spectroscopy of "1"2"7Xe was carried out using "1"2"2Sn("9Be, 4nγ) fusion-evaporation reaction at 48 MeV using INGA facility at Inter-University Accelerator Centre, New Delhi. Details of the analysis and results will be discussed during the conference. (author)

  1. Theoretical Study of the NMR Chemical Shift of Xe in Supercritical Condition

    DEFF Research Database (Denmark)

    Lacerda Junior, Evanildo Gomes; Sauer, Stephan P. A.; Mikkelsen, Kurt Valentin

    2018-01-01

    In this work we investigate the level of theory necessary for reproducing the non-linear variation of the 129Xe nuclear magnetic resonance (NMR) chemical shift with the density of Xe in supercritical conditions. In detail we study how the 129Xe chemical shift depends under these conditions...... on electron correlation, relativistic and many-body effects. The latter are included using a sequential-QM/MM methodology, in which a classical MD simulation is performed first and the chemical shift is then obtained as an average of quantum calculations of 250 MD snapshots conformations carried out for Xen...... this approach we obtain very good agreement with the experimental data, showing that the chemical shift of 129Xe in supercritical conditions is very well described by cluster calculations at the HF level, with small contributions from relativistic and electron correlation effects....

  2. Report of the Subcommittee on Domestic Uranium Enrichment

    International Nuclear Information System (INIS)

    1981-01-01

    A report by the Subcommittee on Domestic Uranium Enrichment to the Atomic Energy Commission is described; which covers the procedure of the domestic uranium enrichment by centrifugal process up to the commercial production, reviewing the current situation in this field. Domestic uranium enrichment is important in the aspects of securing stable enrichment service, establishing sound fuel cycle, and others. As the future target, the production around the year 2000 is set at 3,000 tons SWU per year at least. The business of uranium enrichment, which is now developed in the Power Reactor and Nuclear Fuel Development Corporation, is to be carried out by private enterprise. The contents are as follows: demand and supply balance of uranium enrichment service, significance of domestic uranium enrichment, evaluation of centrifugal uranium enrichment technology, the target of domestic uranium enrichment, the policy of domestic uranium enrichment promotion. (J.P.N.)

  3. Experimental ion mobility measurements in Xe-CH4

    Science.gov (United States)

    Perdigoto, J. M. C.; Cortez, A. F. V.; Veenhof, R.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2017-09-01

    Data on ion mobility is important to improve the performance of large volume gaseous detectors. In the present work, the method, experimental setup and results for the ion mobility measurements in Xe-CH4 mixtures are presented. The results for this mixture show the presence of two distinct groups of ions. The nature of the ions depend on the mixture ratio since they are originated by both Xe and CH4. The results here presented were obtained for low reduced electric fields, E/N, 10-25 Td (2.4-6.1 kV ṡ cm-1 ṡ bar-1), at low pressure (8 Torr) (10.6 mbar), and at room temperature.

  4. Laser generation of XeCl exciplex molecules in a longitudinal repetitively pulsed discharge in a Xe – CsCl mixture

    International Nuclear Information System (INIS)

    Boichenko, A M; Klenovskii, M S

    2015-01-01

    By using the previously developed kinetic model, we have carried out simulations to study the possibility of laser generation of XeCl exciplex molecules in the working medium based on a mixture of Xe with CsCl vapours, excited by a longitudinal repetitively pulsed discharge. The formation mechanism of exciplex molecules in this mixture is fundamentally different from the formation mechanisms in the traditional mixtures of exciplex lasers. The conditions that make the laser generation possible are discussed. For these conditions, with allowance for available specific experimental conditions of the repetitively pulsed discharge excitation, we have obtained the calculated dependences of the power and efficiency of generation on the reflectivity of mirrors in a laser cavity. (active media)

  5. Laser generation of XeCl exciplex molecules in a longitudinal repetitively pulsed discharge in a Xe – CsCl mixture

    Energy Technology Data Exchange (ETDEWEB)

    Boichenko, A M [A M Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation); Klenovskii, M S [National Research Tomsk Polytechnic University, Tomsk (Russian Federation)

    2015-12-31

    By using the previously developed kinetic model, we have carried out simulations to study the possibility of laser generation of XeCl exciplex molecules in the working medium based on a mixture of Xe with CsCl vapours, excited by a longitudinal repetitively pulsed discharge. The formation mechanism of exciplex molecules in this mixture is fundamentally different from the formation mechanisms in the traditional mixtures of exciplex lasers. The conditions that make the laser generation possible are discussed. For these conditions, with allowance for available specific experimental conditions of the repetitively pulsed discharge excitation, we have obtained the calculated dependences of the power and efficiency of generation on the reflectivity of mirrors in a laser cavity. (active media)

  6. MULTI-KEV X-Ray Yields From High-Z Gas Targets Fielded At Omega

    International Nuclear Information System (INIS)

    Kane, J.O.; Fournier, K.B.; May, M.J.; Colvin, J.D.; Thomas, C.A.; Marrs, R.E.; Compton, S.M.; Moody, J.D.; Bond, E.J.; Davis, J.F.

    2010-01-01

    The authors report on modeling of x-ray yield from gas-filled targets shot at the OMEGA laser facility. The OMEGA targets were 1.8 mm long, 1.95 mm in diameter Be cans filled with either a 50:50 Ar:Xe mixture, pure Ar, pure Kr or pure Xe at ∼ 1 atm. The OMEGA experiments heated the gas with 20 kJ of 3ω (∼ 350 nm) laser energy delivered in a 1 ns square pulse. the emitted x-ray flux was monitored with the x-ray diode based DANTE instruments in the sub-keV range. Two-dimensional x-ray images (for energies 3-5 keV) of the targets were recorded with gated x-ray detectors. The x-ray spectra were recorded with the HENWAY crystal spectrometer at OMEGA. Predictions are 2D r-z cylindrical with DCA NLTE atomic physics. Models generally: (1) underpredict the Xe L-shell yields; (2) overpredict the Ar K-shell yields; (3) correctly predict the Xe thermal yields; and (4) greatly underpredict the Ar thermal yields. However, there are spreads within the data, e.g. the DMX Ar K-shell yields are correctly predicted. The predicted thermal yields show strong angular dependence.

  7. Multiple photoionization from 3p excitation of Kr and 4p excitation of Xe

    International Nuclear Information System (INIS)

    Hayaishi, T.

    1986-01-01

    The photoionization cross sections for multiply charged ions produced by 3p excitation of Kr and 4p excitation of Xe have been obtained by means of a time-of-flight mass spectrometer and synchrotron radiation. It is found that the main formation of doubly to quadruply charged ions in both Kr and Xe is caused from the each initial p-hole state through a Coster-Kronig transition followed by Auger of double Auger processes. The formation of singly charged ions in these excitation energy regions is caused by direct photoionization from outermost shell electrons in both Kr and Xe. Triply charged ions are prominently produced among the multiply charged ions. The quadruple photoionization cross sections show clearly the structures due to the Rydberg series, 3p -1 nl of Kr and 4p -1 nl of Xe. Their main structures were assigned to the 3p -1 nd series in Kr and the 4p -1 nd series in Xe. (orig.)

  8. Radiation dosimetry and first therapy results with a {sup 124}I/{sup 131}I-labeled small molecule (MIP-1095) targeting PSMA for prostate cancer therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zechmann, Christian M.; Afshar-Oromieh, Ali; Mier, Walter [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Armor, Tom; Joyal, John [Molecular Insight Pharmaceuticals, Boston, MA (United States); Stubbs, James B. [Radiation Dosimetry Systems RDS, Inc., Apharetta, GA (United States); Hadaschik, Boris [University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Kopka, Klaus [Division Radiopharmaceutical Chemistry, DKFZ, Heidelberg (Germany); Debus, Juergen [University Hospital Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Babich, John W. [Molecular Insight Pharmaceuticals, Boston, MA (United States); Cornell University, Division of Radiopharmacy, Department of Radiology, New York, NY (United States); Haberkorn, Uwe [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Clinical Cooperation Unit Nuclear Medicine, DKFZ, Heidelberg (Germany)

    2014-07-15

    Since the prostate-specific membrane antigen (PSMA) is frequently over-expressed in prostate cancer (PCa) several PSMA-targeting molecules are under development to detect and treat metastatic castration resistant prostate cancer (mCRPC). We investigated the tissue kinetics of a small molecule inhibitor of PSMA ((S)-2-(3-((S)-1-carboxy-5-(3-(4-[{sup 124}I]iodophenyl)ureido)pentyl)ureido) pentan edioicacid; MIP-1095) using PET/CT to estimate radiation dosimetry for the potential therapeutic use of {sup 131}I-MIP-1095 in men with mCRPC. We also report preliminary safety and efficacy of the first 28 consecutive patients treated under a compassionate-use protocol with a single cycle of {sup 131}I-MIP-1095. Sixteen patients with known prostate cancer underwent PET/CT imaging after i.v. administration of {sup 124}I-MIP-1095 (mean activity: 67.4 MBq). Each patient was scanned using PET/CT up to five times at 1, 4, 24, 48 and 72 h post injection. Volumes of interest were defined for tumor lesions and normal organs at each time point followed by dose calculations using the OLINDA/EXM software. Twenty-eight men with mCRPC were treated with a single cycle of {sup 131}I-MIP-1095 (mean activity: 4.8 GBq, range 2 to 7.2 GBq) and followed for safety and efficacy. Baseline and follow up examinations included a complete blood count, liver and kidney function tests, and measurement of serum PSA. I-124-MIP-1095 PET/CT images showed excellent tumor uptake and moderate uptake in liver, proximal intestine and within a few hours post-injection also in the kidneys. High uptake values were observed only in salivary and lacrimal glands. Dosimetry estimates for I-131-MIP-1095 revealed that the highest absorbed doses were delivered to the salivary glands (3.8 mSv/MBq), liver (1.7 mSv/MBq) and kidneys (1.4 mSv/MBq). The absorbed dose calculated for the red marrow was 0.37 mSv/MBq. PSA values decreased by >50 % in 60.7 % of the men treated. Of men with bone pain, 84.6 % showed complete or

  9. I-Xe dating of aqueous alteration in the CI chondrite Orgueil: I. Magnetite and ferromagnetic separates

    Science.gov (United States)

    Pravdivtseva, O.; Krot, A. N.; Hohenberg, C. M.

    2018-04-01

    The I-Xe system was studied in a ferromagnetic sample separated from the Orgueil CI carbonaceous chondrite with a hand-held magnet and in two magnetite samples, one chemically separated before and the other one after neutron irradiation. This work was done in order to investigate the effects of chemical separation by LiCl and NaOH on the I-Xe system in magnetite. Our test demonstrated that the chemical separation of magnetite before irradiation using either LiCl or NaOH, or both, does not contaminate the sample with iodine and thus cannot lead to erroneous I-Xe ages due to introduction of uncorrelated 128∗Xe. The I-Xe ages of two Orgueil magnetite samples are mutually consistent within experimental uncertainties and, when normalized to an absolute time scale with the reevaluated Shallowater aubrite standard, place the onset of aqueous alteration on the CI parent body at 4564.3 ± 0.3 Ma, 2.9 ± 0.3 Ma after formation of the CV Ca-AI-rich inclusions (CAIs). The I-Xe age of the ferromagnetic Orgueil separate is 3.4 Ma younger, corresponding to a closure of the I-Xe system at 4560.9 ± 0.2 Ma. These and previously published I-Xe data for Orgueil (Hohenberg et al., 2000) indicate that aqueous alteration on the CI parent body lasted for at least 5 Ma. Although the two magnetite samples gave indistinguishable I-Xe ages, their temperature release profiles differed. One of the two Orgueil magnetites released less radiogenic Xe than the other, 80% of it corresponding to the low-temperature peak of the release profile, compared to only 6% in case of the second Orgueil magnetite sample. This could be due to the difference in iodine trapping efficiencies for magnetite grains of different morphologies. Alternatively, the magnetite grains with the lower radiogenic Xe concentrations may have formed at a later stage of alteration when iodine in an aqueous solution was depleted.

  10. Results of four one-day electron-accelerator irradiations of enriched Mo-100 targets for the production of Mo-99

    Energy Technology Data Exchange (ETDEWEB)

    Chemerisov, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Bailey, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Heltemes, T. [Argonne National Lab. (ANL), Argonne, IL (United States); Jonah, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Gromov, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Makarashvili, V. [Argonne National Lab. (ANL), Argonne, IL (United States); Tkac, P. [Argonne National Lab. (ANL), Argonne, IL (United States); Rotsch, D. [Argonne National Lab. (ANL), Argonne, IL (United States); Virgo, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, G. F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-10-01

    A series of four one-day irradiations was conducted with 100Mo-enriched disk targets. After irradiation, the enriched disks were removed from the target and dissolved. The resulting solution was processed using a NorthStar RadioGenix™ 99mTc generator either at Argonne National Laboratory or at the NorthStar Medical Radioisotopes facility. Runs on the RadioGenix system produced inconsistent analytical results for 99mTc in the Tc/Mo solution. These inconsistencies were attributed to the impurities in the solution or improper column packing. During the irradiations, the performance of the optic transitional radiation (OTR) and infrared cameras was tested in high radiation field. The OTR cameras survived all irradiations, while the IR cameras failed every time. The addition of X-ray and neutron shielding improved camera survivability and decreased the number of upsets.

  11. Multiperturber effects in the Faraday spectrum of Rb atoms immersed in a high-density Xe gas

    Science.gov (United States)

    Woerdman, J. P.; Blok, F. J.; Kristensen, M.; Schrama, C. A.

    1996-02-01

    We have measured the D1 and D2 Faraday spectrum and absorption spectrum of Rb atoms immersed in high-density Xe buffer gas in the range nXe=0.8-4.5×1020 cm-3. We find that the shape of the Faraday spectrum obeys the Becquerel relation over this whole density range; however the relative strength of the Faraday effect compared to absorption changes rather abruptly near nXe=1×1020 cm-3. This is ascribed to the onset of a many-body nature (overlapping collisions) of the Rb:Xe line broadening; the number of perturbers within the Weisskopf sphere is unity at nXe~1×1020 cm-3.

  12. A method for determining leakage of 133Xe gas from septum-sealed glass vials

    International Nuclear Information System (INIS)

    McAllister, J.R.; Borak, T.B.; Pellicciarini, D.W.

    2000-01-01

    The authors have developed a method for determining the leakage of 133 Xe gas from septum-sealed glass vials that are supplied for medical examinations. Twenty vials each originally containing 370 MPq of 133 Xe and 20 vials each originally containing 740 MBq 133 Xe were measured daily for 26 d. Retention of 133 Xe within the vial was modeled as a first order process with a constant rate coefficient, λ T . The value of λ T was estimated for each vial using a regression analysis. The leakage rate, λ L , was then determined assuming that λ L = λ L + λ r where λ r represents the physical decay of 133 Xe. Monte Carlo simulations were performed using uncertainties in the estimates of each vial to obtain the mean and tails of the distribution for the average leakage rate, bar λ L . the average leakage rate for the complete sample of vials was 0.00007 d -1 with an upper, one-sided, 95% confidence limit of 0.0011 d -1 . Uncertainties in the published values of λ r for 133 Xe made a significant contribution to the uncertainties of the leakage rate for this sample of vials. The methods described can be applied to other situations where leakage of radioactive materials may be of concern

  13. A comparison between the irradiation damage response of spinel and zirconia due to Xe ion bombardment

    International Nuclear Information System (INIS)

    Sickafus, K.E.; Wetteland, C.J.; Baker, N.P.; Yu Ning; Devanathan, R.; Nastasi, M.; Bordes, N.

    1998-01-01

    The mechanical properties of Xe-implanted spinel and cubic zirconia surfaces, as determined by nano-indentation measurements, are distinct and the differences can be related to their microstructures. Upon Xe 2+ ion irradiation to high dose at cryogenic temperature (120 K), the Young's modulus of irradiated spinel falls dramatically until the modulus is only about 3/4 the un-irradiated value. The maximum modulus occurs concurrent with the formation of a metastable crystalline phase of spinel. The subsequent elastic softening at higher Xe 2+ doses is an indication of the onset of amorphization of the spinel. Xe-implanted zirconia surfaces behave differently, in all cases showing almost no change in elastic modulus with increasing Xe 2+ ion dose. This is consistent with microstructural observations of Xe-implanted zirconia crystals which, unlike spinel, show no change in crystal structure with increasing ion dose. The hardness of both spinel and zirconia increases slightly for low Xe 2+ ion doses. At higher doses, zirconia shows little change in hardness, while the hardness of the implanted spinel falls by more than a factor of two. The initial increase in hardness of both spinel and zirconia is consistent with point defect accumulation and the precipitation of small interstitial clusters, while the drop in hardness of spinel at high Xe 2+ ion doses is due to the formation of an amorphous phase. (orig.)

  14. Resistivity and morphology of TiSi2 formed on Xe+-implanted polycrystalline silicon

    International Nuclear Information System (INIS)

    Kuwano, H.; Phillips, J.R.; Mayer, J.W.

    1990-01-01

    Xe ion irradiation of polycrystalline silicon before Ti deposition is found to affect subsequent silicide formation. Silicide films were prepared by implanting 60, 100, or 240 keV Xe + ions into 500-nm-thick undoped polycrystalline silicon before depositing Ti and annealing in vacuum. Preimplantation altered the subsequent silicide resistivity, x-ray diffraction patterns, and morphology as compared to films prepared on unimplanted polycrystalline Si substrates. We found that minimal TiSi 2 resistivities were achieved at lower temperatures with preimplantation, indicating that the Xe-implanted substrate promotes a lower temperature transition from the metastable C49 phase to the low-resistivity equilibrium C54 phase of TiSi 2 . X-ray diffraction results confirmed the lower temperature formation of the C54 phase with preimplantation. Low-temperature annealing (650 degree C, 30 min) of 6x10 16 cm -2 , 240 keV Xe + -implanted samples yielded low-resistivity (∼22 μΩ cm) silicide films, while simultaneously annealed samples without preimplantation had resistivity five times higher. Lower doses were effective at lower implant energies, with low resistivity achieved after 725 degree C, 30 min annealing for 2x10 15 cm -2 , 60 keV Xe + preimplantation

  15. Xe-133 recuperation by adsorption in active carbon impregnated with PF5

    International Nuclear Information System (INIS)

    Mondino, A.V.; Marques, R.O.

    1990-01-01

    Since the Mo-99 Fission Project has the aim to produce Xe-133 from gases generated in the alkaline dissolution of Al-U plates irradiated with thermal neutrons and, considering the importance of this radioisotope from the nuclear medicine point of view, studies to improve and optimize the Xe-133 recuperation were continued. Experiences were made on 'static' equilibrium employing high purity xenon and for the 'dynamic' case, Xe-133 mixed with a carrier and nitrogen as gas carrier; in this case, a 44% and a 34% increase in the capacity of xenon adsorption relaxed with activated carbon without being impregnated and impregnated with AgF, were respectively achieved. (Author) [es

  16. Soft x-ray source by laser produced Xe plasma

    International Nuclear Information System (INIS)

    Amano, Sho; Masuda, Kazuya; Miyamoto, Shuji; Mochizuki, Takayasu

    2010-01-01

    The laser plasma soft X-ray source in the wavelength rage of 5-17 nm was developed, which consisted of the rotating drum system supplying cryogenic Xe target and the high repetition rate pulse Nd:YAG slab laser. We found the maximum conversion efficiency of 30% and it demonstrated the soft X-ray generation with the high repetition rate pulse of 320 pps and the high average power of 20 W. The soft X-ray cylindrical mirror was developed and successfully focused the soft X-ray with an energy intensity of 1.3 mJ/cm 2 . We also succeeded in the plasma debris mitigation with Ar gas. This will allow a long lifetime of the mirror and a focusing power intensity of 400 mW/cm 2 with 320 pps. The high power soft X-ray is useful for various applications. (author)

  17. Exploring new Xe-129 chemical shift ranges in HXeY compounds: hydrogen more relativistic than xenon

    Czech Academy of Sciences Publication Activity Database

    Lantto, P.; Standara, Stanislav; Riedel, S.; Vaara, J.; Straka, Michal

    2012-01-01

    Roč. 14, č. 31 (2012), s. 10944-10952 ISSN 1463-9076 R&D Projects: GA ČR GA203/09/2037 Grant - others:GA MŠk(CZ) LM2010005; 7th European Framework Program(XE) 230955; CEITEC(XE) CZ.1.05/1.1.00/02.0068 Institutional research plan: CEZ:AV0Z40550506 Keywords : 129Xe NMR * novel Xe compounds * relativistic effects * rare-gas * ab-initio * NMR properties Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.829, year: 2012

  18. Experimental ion mobility measurements in Xe-C2H6

    Science.gov (United States)

    Perdigoto, J. M. C.; Cortez, A. F. V.; Veenhof, R.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2017-10-01

    In this paper we present the results of the ion mobility measurements made in gaseous mixtures of xenon (Xe) with ethane (C2H6) for pressures ranging from 6 to 10 Torr (8-10.6 mbar) and for low reduced electric fields in the 10 Td to 25 Td range (2.4-6.1 kVṡcm-1ṡ bar-1), at room temperature. The time of arrival spectra revealed two peaks throughout the entire range studied which were attributed to ion species with 3-carbons (C3H5+, C3H6+ C3H8+ and C3H9+) and with 4-carbons (C4H7+, C4H9+ and C4H10+). Besides these, and for Xe concentrations above 70%, a bump starts to appear at the right side of the main peak for reduced electric fields higher than 20 Td, which was attributed to the resonant charge transfer of C2H6+ to C2H6 that affects the mobility of its ion products (C3H8+ and C3H9+). The time of arrival spectra for Xe concentrations of 20%, 50%, 70% and 90% are presented, together with the reduced mobilities as a function of the Xe concentration calculated from the peaks observed for the low reduced electric fields and pressures studied.

  19. 42 CFR 124.8 - Grantee accountability.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Grantee accountability. 124.8 Section 124.8 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES HEALTH RESOURCES DEVELOPMENT... and Modernization § 124.8 Grantee accountability. (a) Records requirements. (1) Applicants who have...

  20. Novel 1H-1,2,3-, 2H-1,2,3-, 1H-1,2,4- and 4H-1,2,4-triazole derivatives: a patent review (2008 - 2011).

    Science.gov (United States)

    Ferreira, Vitor F; da Rocha, David R; da Silva, Fernando C; Ferreira, Patrícia G; Boechat, Núbia A; Magalhães, Jorge L

    2013-03-01

    The triazoles represent a class of five-membered heterocyclic compounds of great importance for the preparation of new drugs with diverse biological activities because they may present several structural variations with the same numbers of carbon and nitrogen atoms. Due to the success of various triazoles that entered the pharmaceutical market and are still being used in medicines, many companies and research groups have shown interest in developing new methods of synthesis and biological evaluation of potential uses for these compounds. In this review, the authors explored aspects of patents for the 1H-1,2,3-, 2H-1,2,3-, 1H-1,2,4- and 4H-1,2,4-triazole families, including prototypes being considered in clinical studies between 2008 and 2011. The triazoles have been studied for over a century as an important class of heterocyclic compounds and still attract considerable attention due to their broad range of biological activities. More recently, there has been considerable interest in the development of novel triazoles with anti-inflammatory, antiplatelet, antimicrobial, antimycobacterial, antitumoral and antiviral properties and activity against several neglected diseases. This review emphasizes recent perspective and advances in the therapeutically active 1H-1,2,3-, 2H-1,2,3-, 1H-1,2,4- and 4H-1,2,4-triazole derivative patents between 2008 and 2011, covering the development of new chemical entities and new pharmaceuticals. Many studies have focused on these compounds as target structures and evaluated them in several biological targets. The preparation of 1H-1,2,3-, 2H-1,2,3-, 1H-1,2,4- and 4H-1,2,4-triazole derivatives brings to light several issues. There is a need to find new, more efficient preparations for these triazoles that take into consideration current issues in green chemistry, energy saving and sustainability. New diseases are discovered and new viruses and bacteria continue to challenge mankind, so it is imperative to find new prototypes for these

  1. The Supply of Medical Radioisotopes. Market impacts of converting to low-enriched uranium targets for medical isotope production

    International Nuclear Information System (INIS)

    Westmacott, Chad; Cameron, Ron

    2012-01-01

    The reliable supply of molybdenum-99 ( 99 Mo) and its decay product, technetium-99m ( 99m Tc), is a vital component of modern medical diagnostic practices. At present, most of the global production of 99 Mo is from highly enriched uranium (HEU) targets. However, all major 99 Mo-producing countries have recently agreed to convert to using low-enriched uranium (LEU) targets to advance important non-proliferation goals, a decision that will have implications for the global supply chain of 99 Mo/ 99m Tc and the long-term supply reliability of these medical isotopes. This study provides the findings and analysis from an extensive examination of the 99 Mo/ 99m Tc supply chain by the OECD/NEA High-level Group on the Security of Supply of Medical Radioisotopes (HLG-MR). It presents a comprehensive evaluation of the potential impacts of converting to the use of LEU targets for 99 Mo production on the global 99 Mo/ 99m Tc market in terms of costs and available production capacity, and the corresponding implications for long-term supply reliability. In this context, the study also briefly discusses the need for policy action by governments in their efforts to ensure a stable and secure long-term supply of 99 Mo/ 99m Tc

  2. Thermally stimulated exoelectron emission from solid Xe

    International Nuclear Information System (INIS)

    Khyzhniy, I.V.; Grigorashchenko, O.N.; Savchenko, E.V.; Ponomarev, A.N.; Bondybey, V.E.

    2007-01-01

    Thermally-stimulated emission of exoelectrons and photons from solid Xe pre-irradiated by low-energy electrons were studied. A high sensitivity of thermally-stimulated luminescence (TSL) and thermally-stimulated exoelectron emission (TSEE) to sample prehistory was demonstrated. It was shown that electron traps in unannealed samples are characterized by much broader distribution of trap levels in comparison with annealed samples and their concentration exceeds in number that in annealed samples. Both phenomena, TSL and TSEE, were found to be triggered by release of electrons from the same kind of traps. The data obtained suggest a competition between two relaxation channels: charge recombination and electron transport terminated by TSL and TSEE. It was found that TSEE predominates at low temperatures while at higher temperatures TSL prevails. An additional relaxation channel, a photon-stimulated exoelectron emission pre-irradiated solid Xe, was revealed

  3. The partition coefficients of 133Xe between blood and bone

    International Nuclear Information System (INIS)

    Lahtinen, T.; Karjalainen, P.; Vaeaenaenen, A.; Lahtinen, R.; Alhava, E.M.

    1981-01-01

    The partition coefficients of 133 Xe between blood and haematopoietic bone marrow and homogenised bone have been determined in vitro. The partition coefficient lambda 1 corresponding to haematopoietic marrow was 0.95 ml g -1 while that corresponding to homogenised bone was a function of age, lambda 2 = 3.11 + 0.049(age)(ml g -1 ). These data can be used for calculating regional blood flow in healthy human femur by means of a simple 133 Xe radionuclide method. (author)

  4. 7 CFR 4280.124 - Interest rates.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Interest rates. 4280.124 Section 4280.124 Agriculture... Improvements Program Section B. Guaranteed Loans § 4280.124 Interest rates. (a) The interest rate for the... in similar circumstances in the ordinary course of business. The interest rate charged is subject to...

  5. Searches for Lorentz violation in {sup 3}He/{sup 129}Xe clock comparison experiments

    Energy Technology Data Exchange (ETDEWEB)

    Allmendinger, F. [Universitaet Heidelberg, Physikalisches Institut (Germany); Burghoff, M. [Physikalisch-Technische Bundesanstalt (Germany); Heil, W., E-mail: wheil@uni-mainz.de; Karpuk, S. [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany); Kilian, W.; Knappe-Grueneberg, S.; Mueller, W. [Physikalisch-Technische Bundesanstalt (Germany); Schmidt, U. [Universitaet Heidelberg, Physikalisches Institut (Germany); Schnabel, A.; Seifert, F. [Physikalisch-Technische Bundesanstalt (Germany); Sobolev, Yu [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany); Trahms, L. [Physikalisch-Technische Bundesanstalt (Germany); Tullney, K. [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany)

    2013-03-15

    We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized {sup 3}He or {sup 129}Xe samples with a SQUID as magnetic flux detector. Characteristic spin precession times T{sub 2}{sup Asterisk-Operator} of up to 115 h were measured in low magnetic fields (about 1 {mu}T) and in the regime of motional narrowing. With the detection of the free precession of co-located {sup 3}He/{sup 129}Xe nuclear spins (clock comparison), the device can be used as ultra-sensitive probe for non-magnetic spin interactions, since the magnetic dipole interaction (Zeeman-term) drops out in the weighted frequency difference, i.e., {Delta}{omega} = {omega}{sub He} - {gamma}{sub He}/{gamma}{sub Xe}{center_dot}{omega}{sub Xe}. We report on searches for Lorentz violating signatures by monitoring the Larmor frequencies of co-located {sup 3}He/{sup 129}Xe spin samples as the laboratory reference frame rotates with respect to distant stars (sidereal modulation).

  6. Nuclear spin relaxation due to chemical shift anisotropy of gas-phase 129Xe.

    Science.gov (United States)

    Hanni, Matti; Lantto, Perttu; Vaara, Juha

    2011-08-14

    Nuclear spin relaxation provides detailed dynamical information on molecular systems and materials. Here, first-principles modeling of the chemical shift anisotropy (CSA) relaxation time for the prototypic monoatomic (129)Xe gas is carried out, both complementing and predicting the results of NMR measurements. Our approach is based on molecular dynamics simulations combined with pre-parametrized ab initio binary nuclear shielding tensors, an "NMR force field". By using the Redfield relaxation formalism, the simulated CSA time correlation functions lead to spectral density functions that, for the first time, quantitatively determine the experimental spin-lattice relaxation times T(1). The quality requirements on both the Xe-Xe interaction potential and binary shielding tensor are investigated in the context of CSA T(1). Persistent dimers Xe(2) are found to be responsible for the CSA relaxation mechanism in the low-density limit of the gas, completely in line with the earlier experimental findings.

  7. Solid and liquid 129Xe NMR signals enhanced by spin-exchange optical pumping under flow

    International Nuclear Information System (INIS)

    Zhou Xin; Luo Jun; Sun Xianping; Zeng Xizhi; Liu Maili; Liu Wuyang

    2002-01-01

    Laser-polarized 129 Xe gas was produced by spin-exchange with Cs atom optically pumped with diode laser array in a low field under flow. The nuclear spin polarizations of the solid and liquid 129 Xe frozen from the laser-polarized 129 Xe gas were 2.16% and 1.45% respectively in the SY-80M NMR spectrometer, which corresponded to the enhancements of 6000 and 5000 compared to those without optical pumping under the same conditions. It could provide the base and possibility for quantum computers using laser-enhanced solid and liquid 129 Xe. Polarization loss of transport and state change was also discussed

  8. Gpr124 is essential for blood-brain barrier integrity in central nervous system disease.

    Science.gov (United States)

    Chang, Junlei; Mancuso, Michael R; Maier, Carolina; Liang, Xibin; Yuki, Kanako; Yang, Lu; Kwong, Jeffrey W; Wang, Jing; Rao, Varsha; Vallon, Mario; Kosinski, Cynthia; Zhang, J J Haijing; Mah, Amanda T; Xu, Lijun; Li, Le; Gholamin, Sharareh; Reyes, Teresa F; Li, Rui; Kuhnert, Frank; Han, Xiaoyuan; Yuan, Jenny; Chiou, Shin-Heng; Brettman, Ari D; Daly, Lauren; Corney, David C; Cheshier, Samuel H; Shortliffe, Linda D; Wu, Xiwei; Snyder, Michael; Chan, Pak; Giffard, Rona G; Chang, Howard Y; Andreasson, Katrin; Kuo, Calvin J

    2017-04-01

    Although blood-brain barrier (BBB) compromise is central to the etiology of diverse central nervous system (CNS) disorders, endothelial receptor proteins that control BBB function are poorly defined. The endothelial G-protein-coupled receptor (GPCR) Gpr124 has been reported to be required for normal forebrain angiogenesis and BBB function in mouse embryos, but the role of this receptor in adult animals is unknown. Here Gpr124 conditional knockout (CKO) in the endothelia of adult mice did not affect homeostatic BBB integrity, but resulted in BBB disruption and microvascular hemorrhage in mouse models of both ischemic stroke and glioblastoma, accompanied by reduced cerebrovascular canonical Wnt-β-catenin signaling. Constitutive activation of Wnt-β-catenin signaling fully corrected the BBB disruption and hemorrhage defects of Gpr124-CKO mice, with rescue of the endothelial gene tight junction, pericyte coverage and extracellular-matrix deficits. We thus identify Gpr124 as an endothelial GPCR specifically required for endothelial Wnt signaling and BBB integrity under pathological conditions in adult mice. This finding implicates Gpr124 as a potential therapeutic target for human CNS disorders characterized by BBB disruption.

  9. Atomistic simulations of thermodynamic properties of Xe gas bubbles in U10Mo fuels

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Shenyang, E-mail: shenyang.hu@pnnl.gov; Setyawan, Wahyu; Joshi, Vineet V.; Lavender, Curt A.

    2017-07-15

    Xe gas bubble superlattice formation is observed in irradiated uranium–10 wt% molybdenum (U10Mo) fuels. However, the thermodynamic properties of the bubbles (the relationship among bubble size, equilibrium Xe concentration, and bubble pressure) and the mechanisms of bubble superlattice formation are not well known. In this work, the molecular dynamics (MD) method is used to study these properties and mechanisms. The results provide important inputs for quantitative mesoscale models of gas bubble evolution and fuel performance. In the MD simulations, the embedded-atom method (EAM) potential of U10Mo-Xe [1] is employed. Initial gas bubbles with a low Xe concentration (underpressured) are generated in a body-centered cubic (bcc) U10Mo single crystal. Then Xe atoms are sequentially added into the bubbles one by one, and the evolution of pressure and dislocation emission around the bubbles is analyzed. The relationship between pressure, equilibrium Xe concentration, and radius of the bubbles is established. It was found that an overpressured gas bubble emits partial dislocations with a Burgers vector along the <111> direction and a slip plane of (11-2). Meanwhile, dislocation loop punch out was not observed. The overpressured bubble also induces an anisotropic stress field. A tensile stress was found along <110> directions around the bubble, favoring the nucleation and formation of a face-centered cubic bubble superlattice in bcc U10Mo fuels.

  10. Atomistic simulations of thermodynamic properties of Xe gas bubbles in U10Mo fuels

    Science.gov (United States)

    Hu, Shenyang; Setyawan, Wahyu; Joshi, Vineet V.; Lavender, Curt A.

    2017-07-01

    Xe gas bubble superlattice formation is observed in irradiated uranium-10 wt% molybdenum (U10Mo) fuels. However, the thermodynamic properties of the bubbles (the relationship among bubble size, equilibrium Xe concentration, and bubble pressure) and the mechanisms of bubble superlattice formation are not well known. In this work, the molecular dynamics (MD) method is used to study these properties and mechanisms. The results provide important inputs for quantitative mesoscale models of gas bubble evolution and fuel performance. In the MD simulations, the embedded-atom method (EAM) potential of U10Mo-Xe [1] is employed. Initial gas bubbles with a low Xe concentration (underpressured) are generated in a body-centered cubic (bcc) U10Mo single crystal. Then Xe atoms are sequentially added into the bubbles one by one, and the evolution of pressure and dislocation emission around the bubbles is analyzed. The relationship between pressure, equilibrium Xe concentration, and radius of the bubbles is established. It was found that an overpressured gas bubble emits partial dislocations with a Burgers vector along the direction and a slip plane of (11-2). Meanwhile, dislocation loop punch out was not observed. The overpressured bubble also induces an anisotropic stress field. A tensile stress was found along directions around the bubble, favoring the nucleation and formation of a face-centered cubic bubble superlattice in bcc U10Mo fuels.

  11. 21 CFR 163.124 - White chocolate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false White chocolate. 163.124 Section 163.124 Food and... CONSUMPTION CACAO PRODUCTS Requirements for Specific Standardized Cacao Products § 163.124 White chocolate. (a) Description. (1) White chocolate is the solid or semiplastic food prepared by intimately mixing and grinding...

  12. 10 CFR 600.124 - Program income.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Program income. 600.124 Section 600.124 Energy DEPARTMENT... Nonprofit Organizations Post-Award Requirements § 600.124 Program income. (a) The standards set forth in this section shall be used to account for program income related to projects financed in whole or in...

  13. 14 CFR 1260.124 - Program income.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Program income. 1260.124 Section 1260.124..., Hospitals, and Other Non-Profit Organizations Post-Award Requirements § 1260.124 Program income. (a) The standards set forth in this section shall be used to account for program income related to projects financed...

  14. 42 CFR 436.124 - Newborn children.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Newborn children. 436.124 Section 436.124 Public... the Categorically Needy § 436.124 Newborn children. (a) The agency must provide Medicaid eligibility to a child born to a woman who has applied for, has been determined eligible and is receiving...

  15. Accelerator production of 99mTc with proton beams and enriched 100Mo targets

    International Nuclear Information System (INIS)

    Lagunas-Solar, M.C.

    1999-01-01

    The direct production of 99m Tc has been developed based upon the use of the 100 Mo(p,2n) 99m Tc reaction (Q= -7.9 MeV), using enriched 100 Mo targets and accelerated protons of 99m Tc yields measured in this work reached 851 ± 77 MBq/μA/h (23.0 ± 3.0 mCi/μA/h) at end-of-bombardment (EOB) in the 22-12 MeV energy region, with 96 Tc (4.35 d) as the only detectable impurity at - accelerators, and by extracting multiple H + beams to bombard a single or an array of enriched 100 Mo targets, this method could provide nearly 851 GBq (23 Ci) of 99m Tc in 1-h bombardments. Because of this large-batch potential, this new method appears to be an effective alternative to the production and distribution of 99 Mo → 99m Tc generator systems, although it may be limited to daily, regional/local distribution and use. 99m Tc produced in this fashion has high radionuclidic and radiochemical purity, although its specific activity has not been determined. The accelerator-made 99m Tc has been shown to have similar physical and chemical characteristics than 99m Tc eluted from commercial fission-produced 99 Mo → 99m Tc generators. Technical and logistical factors need further study and analysis but the potential and the expected impact of this new method are clear in the context of the operation of large radionuclide distribution centers as well as for small programs in developing regions. (author)

  16. p-process xenon isotope anomalies in stardust grains from meteorites

    International Nuclear Information System (INIS)

    Ott, U.

    2013-01-01

    Full text: In measurements on 'bulk' samples of meteorites isotopic variations due to the p-process usually have taken a backseat compared to such in s- or r-isotopes, and, in the best case, can be qualitatively attributed to the p-process, with little to no inferences concerning detailed isotopic yields. The situation is different for grains of stardust that survived in primitive meteorites. In fact, isotopically strange xenon was the key feature that led to the first identification of a stardust mineral, nanodiamonds containing xenon with overabundances of up to a factor of ∼2 in both the r-only (≡H-Xe) and p-only (≡L-Xe) isotopes. Relative excesses of the two r-only isotopes ( 134 Xe, 136 Xe) as well as of the two p-only isotopes ( 124 Xe, 126 Xe) are not equal, hence the processes responsible for HL-xenon must differ from the 'average' r- and p-processes as reflected in solar system abundances. However, while considerable effort has been put into explaining H-Xe, there has been little work on the p-side (L-Xe). Relying on scarce nuclear data, Heymann and Dziczkaniec have studied photodisintegration reactions of Xe and Ba seeds in intermediate zones of supernovae and found that the relative production of the p-Xe isotopes depends sensitively on the yield of the (γ, α) reaction on 128 Ba. Another suggestion - applicable to both the r- and p-anomalies in diamond xenon - is that of a 'rapid separation' between stable Xe isotopes and radioactive precursors produced in the 'standard' p- (as well as r-) process. For the p-isotopes to work, this would require the bulk (87%) of 126 Xe to be produced via the 126 Ba precursor, with a half live of ∼100 minutes, in order to explain the high 124 Xe/ 126 Xe. In contrast to diamond xenon, xenon in silicon carbide contains - besides the component from the s-process in their parent AGB stars - 'almost normal' Xe, with indications for 124 Xe/ 126 Xe being few (∼8)% lower than in solar Xe.

  17. Reduced expression of brain-enriched microRNAs in glioblastomas permits targeted regulation of a cell death gene.

    Directory of Open Access Journals (Sweden)

    Rebecca L Skalsky

    Full Text Available Glioblastoma is a highly aggressive malignant tumor involving glial cells in the human brain. We used high-throughput sequencing to comprehensively profile the small RNAs expressed in glioblastoma and non-tumor brain tissues. MicroRNAs (miRNAs made up the large majority of small RNAs, and we identified over 400 different cellular pre-miRNAs. No known viral miRNAs were detected in any of the samples analyzed. Cluster analysis revealed several miRNAs that were significantly down-regulated in glioblastomas, including miR-128, miR-124, miR-7, miR-139, miR-95, and miR-873. Post-transcriptional editing was observed for several miRNAs, including the miR-376 family, miR-411, miR-381, and miR-379. Using the deep sequencing information, we designed a lentiviral vector expressing a cell suicide gene, the herpes simplex virus thymidine kinase (HSV-TK gene, under the regulation of a miRNA, miR-128, that was found to be enriched in non-tumor brain tissue yet down-regulated in glioblastomas, Glioblastoma cells transduced with this vector were selectively killed when cultured in the presence of ganciclovir. Using an in vitro model to recapitulate expression of brain-enriched miRNAs, we demonstrated that neuronally differentiated SH-SY5Y cells transduced with the miRNA-regulated HSV-TK vector are protected from killing by expression of endogenous miR-128. Together, these results provide an in-depth analysis of miRNA dysregulation in glioblastoma and demonstrate the potential utility of these data in the design of miRNA-regulated therapies for the treatment of brain cancers.

  18. 42 CFR 124.503 - Compliance level.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Compliance level. 124.503 Section 124.503 Public... Unable To Pay § 124.503 Compliance level. (a) Annual compliance level. Subject to the provisions of this... persons unable to pay if it provides for the fiscal year uncompensated services at a level not less than...

  19. He 3 -Xe 129 Comagnetometery using Rb 87 Detection and Decoupling

    Science.gov (United States)

    Limes, M. E.; Sheng, D.; Romalis, M. V.

    2018-01-01

    We describe a He 3 -Xe 129 comagnetometer using Rb 87 atoms for noble-gas spin polarization and detection. We use a train of Rb 87 π pulses and σ+/σ- optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation. We suppress frequency shifts from polarized Rb by measuring the He 3 and Xe 129 spin precession frequencies in the dark, while applying π pulses along two directions to depolarize Rb atoms. The plane of the π pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins. We measure the ratio of He 3 to Xe 129 spin precession frequencies with sufficient absolute accuracy to resolve Earth's rotation without changing the orientation of the comagnetometer. A frequency resolution of 7 nHz is achieved after integration for 8 h without evidence of significant drift.

  20. Measurement of electron drift velocities in the mixture of Xe and He for a new high-pressure Xe gamma-ray detector

    CERN Document Server

    Kobayashi, S; Dmitrenko, V V

    2003-01-01

    Drift velocities of electrons in a mixture of Xe (20 atm)-He (3 atm) were measured using a cylindrical high-pressure xenon chamber. The drift velocities were found to be greater than 3x10 sup 5 cm/s above the reduced electric field of 2.0x10 sup - sup 1 sup 8 V centre dot cm sup 2 at room temperature, which are close to those in Xe-H sub 2 (0.3%). The mixture of He gas into high-pressure xenon improved the resolving time of detectors because it increased the electron drift velocities. This implies that a high-pressure xenon chamber mixed with sup 3 He instead of He gas operates as a gamma-ray detector sensitive to thermal neutrons. (author)

  1. Comments on applications of reduced enrichment fuels

    International Nuclear Information System (INIS)

    Winkler, M.H.

    1983-01-01

    Full text: I will briefly describe the experience gained using different fuels in the SAPHIR reactor in Switzerland. The SAPHIR has been operating since 1957 and was the first swimming pool reactor built outside of the United States, which was originally known as the Geneva Conference Reactor. The first core was loaded with 20 percent enriched high density UO 2 fuel with a density of about 2.5 grams per cc, fabricated in 1955 by Oak Ridge National Laboratory. After a few years of operation at a power level of one MW, more than one batch of the elements released small amounts of fission products mainly Xe and Kr. When these releases were discovered, high enriched fuel was becoming available so that the fuel fabricators began to produce the lower density high enriched fuels. During this transition from fabrication of low to high enriched fuels no one could foresee that the stone age of nuclear fuel fabrication would come back again. Therefore, we did not investigate the reasons for the fission product release from the high density low enriched UO 2 fuel. The second fuel type used in the SAPHIR was the 90 percent enriched low density U 3 O 8 fuel fabricated by NUKEM. This high enriched fuel has performed satisfactorily over the years. Since 1968, the core has been using improved 23 plate fuel elements with a loading of 280 grams of uranium. The reactor power has been recently increased to five MW. An additional increase in the power level to 10 MW is planned at the end of next year so that heavier loaded elements will be needed. In order to follow the recommendations of the INFCE working group 8C and in cooperation with the reduced enrichment program, we intend to initially reduce the fuel enrichment to 45 percent. Last year we ordered five fuel elements with a loading of 320 grams 235 U/element and 45 percent enrichment for full power tests. Unfortunately, the delivery of the necessary enriched fuel uranium has been delayed and it is not available at this time. If

  2. Presolar Diamond in Meteorites

    OpenAIRE

    Amari, Sachiko

    2009-01-01

    Presolar diamond, the carrier of the isotopically anomalous Xe component Xe-HL, was the first mineral type of presolar dust that was isolated from meteorites. The excesses in the light, p-process only isotopes 124Xe and 126Xe, and in the heavy, r-process only isotopes 134Xe and 136Xe relative to the solar ratios indicate that Xe-HL was produced in supernovae: they are the only stellar source where these two processes are believed to take place. Although these processes occur in supernovae, th...

  3. Study of the portal blood flow by gamma-scintigraphy in rectal administration of 133Xe solution

    International Nuclear Information System (INIS)

    Vorontsov, Yu.P.; Dmitrievnkov, B.N.; Andronov, S.V.; Alferov, G.A.

    1981-01-01

    Data on 133 Xe running through the liver during the administration of its solutions rectally (intraintestinally) and directly into the system of the portal vein (into one of the mesenteric veins) have been correlated in experiment on 12 rabbits. Good correlation of the mean of 133 Xe (passing has been shown for both methods of the portal blood flow study). A possibility to study the hepatic blood flow on the basis of clinical results using rectal administration of 133 Xe solution is discussed. The authors discuss the mechanism of 133 Xe penetration from the solution into the blood through the rectal wall

  4. Targeted Screening With Combined Age- and Morphology-Based Criteria Enriches Detection of Lynch Syndrome in Endometrial Cancer.

    Science.gov (United States)

    Lin, Douglas I; Hecht, Jonathan L

    2016-06-01

    Endometrial cancer is associated with Lynch syndrome in 2% to 6% of cases. Adequate screening may prevent of a second cancer and incident cancers in family members via risk-reducing strategies. The goal of the study was to evaluate the detection rate of Lynch syndrome via a targeted screening approach. In 2009, we incorporated targeted Lynch syndrome screening via immunohistochemistry for MLH1, PMS2, MSH2, and MSH6, followed by MLH1 promoter hypermethylation, in select cases of endometrial carcinoma. Criteria for patient selection included (1) all patients Lynch syndrome. Therefore, targeted screening with combined age and morphology based criteria enriches detection of Lynch syndrome in endometrial cancer. However, the detection rate is lower than the rates from published series that offer universal screening. © The Author(s) 2016.

  5. Comparison of air space measurement imaged by CT, small-animal CT, and hyperpolarized Xe MRI

    Science.gov (United States)

    Madani, Aniseh; White, Steven; Santyr, Giles; Cunningham, Ian

    2005-04-01

    Lung disease is the third leading cause of death in the western world. Lung air volume measurements are thought to be early indicators of lung disease and markers in pharmaceutical research. The purpose of this work is to develop a lung phantom for assessing and comparing the quantitative accuracy of hyperpolarized xenon 129 magnetic resonance imaging (HP 129Xe MRI), conventional computed tomography (HRCT), and highresolution small-animal CT (μCT) in measuring lung gas volumes. We developed a lung phantom consisting of solid cellulose acetate spheres (1, 2, 3, 4 and 5 mm diameter) uniformly packed in circulated air or HP 129Xe gas. Air volume is estimated based on simple thresholding algorithm. Truth is calculated from the sphere diameters and validated using μCT. While this phantom is not anthropomorphic, it enables us to directly measure air space volume and compare these imaging methods as a function of sphere diameter for the first time. HP 129Xe MRI requires partial volume analysis to distinguish regions with and without 129Xe gas and results are within %5 of truth but settling of the heavy 129Xe gas complicates this analysis. Conventional CT demonstrated partial-volume artifacts for the 1mm spheres. μCT gives the most accurate air-volume results. Conventional CT and HP 129Xe MRI give similar results although non-uniform densities of 129Xe require more sophisticated algorithms than simple thresholding. The threshold required to give the true air volume in both HRCT and μCT, varies with sphere diameters calling into question the validity of thresholding method.

  6. Blueprint for domestic uranium enrichment

    International Nuclear Information System (INIS)

    1981-01-01

    The AEC advisory committee on domestic production of uranium enrichment has studied for more than a year how to achieve the domestic enrichment of uranium by the construction and operation of a commercial enriching plant using centrifugal separation method, and the report was submitted to the Atomic Energy Commission on August 18, 1980. Japan has depended wholly on overseas services for her uranium enrichment needs, but the development of domestic enrichment has been carried on in parallel. The AEC decided to construct a uranium enrichment pilot plant using centrifuges, and it has been forwarded as a national project. The plant is operated by the Power Reactor and Nuclear Fuel Development Corp. since 1979. The capacity of the plant will be raised to approximately 75 ton SWU a year. The centrifuges already operated have provided the first delivery of fuel of about 1 ton for the ATR ''Fugen''. The demand-supply balance of uranium enrichment service, the significance of the domestic enrichment of uranium, the evaluation of uranium enrichment technology, the target for domestic enrichment plan, the measures to promote domestic uranium enrichment, and the promotion of the construction of a demonstration plant are reported. (Kako, I.)

  7. 7 CFR 959.124 - Reports.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Reports. 959.124 Section 959.124 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements...; destination; consignee; the inspection certificate number when inspection is required; and any other...

  8. 7 CFR 948.124 - Reports.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Reports. 948.124 Section 948.124 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... point; destination; consignee; the inspection certificate number when inspection is required; and any...

  9. EXTERNAL PHOTOEVAPORATION OF THE SOLAR NEBULA: JUPITER's NOBLE GAS ENRICHMENTS

    International Nuclear Information System (INIS)

    Monga, Nikhil; Desch, Steven

    2015-01-01

    We present a model explaining the elemental enrichments in Jupiter's atmosphere, particularly the noble gases Ar, Kr, and Xe. While He, Ne, and O are depleted, seven other elements show similar enrichments (∼3 times solar, relative to H). Being volatile, Ar is difficult to fractionate from H 2 . We argue that external photoevaporation by far-ultraviolet (FUV) radiation from nearby massive stars removed H 2 , He, and Ne from the solar nebula, but Ar and other species were retained because photoevaporation occurred at large heliocentric distances where temperatures were cold enough (≲ 30 K) to trap them in amorphous water ice. As the solar nebula lost H, it became relatively and uniformly enriched in other species. Our model improves on the similar model of Guillot and Hueso. We recognize that cold temperatures alone do not trap volatiles; continuous water vapor production is also necessary. We demonstrate that FUV fluxes that photoevaporated the disk generated sufficient water vapor in regions ≲ 30 K to trap gas-phase species in amorphous water ice in solar proportions. We find more efficient chemical fractionation in the outer disk: whereas the model of Guillot and Hueso predicts a factor of three enrichment when only <2% of the disk mass remains, we find the same enrichments when 30% of the disk mass remains. Finally, we predict the presence of ∼0.1 M ⊕ of water vapor in the outer solar nebula and protoplanetary disks in H II regions

  10. Relaxation rates of low-field gas-phase ^129Xe storage cells

    Science.gov (United States)

    Limes, Mark; Saam, Brian

    2010-10-01

    A study of longitudinal nuclear relaxation rates T1 of ^129Xe and Xe-N2 mixtures in a magnetic field of 3.8 mT is presented. In this regime, intrinsic spin relaxation is dominated by the intramolecular spin-rotation interaction due to persistent xenon dimers, a mechanism that can be quelled by introducing large amounts of N2 into the storage cell. Extrinsic spin relaxation is dominated by the wall-relaxation rate, which is the primary quantity of interest for the various low-field storage cells and coatings that we have tested. Previous group work has shown that extremely long gas-phase relaxation times T1 can be obtained, but only at large magnetic fields and low xenon densities. The current work is motivated by the practical benefits of retaining hyperpolarized ^129Xe for extended periods of time in a small magnetic field.

  11. Cell adhesion controlled by adhesion G protein-coupled receptor GPR124/ADGRA2 is mediated by a protein complex comprising intersectins and Elmo-Dock.

    Science.gov (United States)

    Hernández-Vásquez, Magda Nohemí; Adame-García, Sendi Rafael; Hamoud, Noumeira; Chidiac, Rony; Reyes-Cruz, Guadalupe; Gratton, Jean Philippe; Côté, Jean-François; Vázquez-Prado, José

    2017-07-21

    Developmental angiogenesis and the maintenance of the blood-brain barrier involve endothelial cell adhesion, which is linked to cytoskeletal dynamics. GPR124 (also known as TEM5/ADGRA2) is an adhesion G protein-coupled receptor family member that plays a pivotal role in brain angiogenesis and in ensuring a tight blood-brain barrier. However, the signaling properties of GPR124 remain poorly defined. Here, we show that ectopic expression of GPR124 promotes cell adhesion, additive to extracellular matrix-dependent effect, coupled with filopodia and lamellipodia formation and an enrichment of a pool of the G protein-coupled receptor at actin-rich cellular protrusions containing VASP, a filopodial marker. Accordingly, GPR124-expressing cells also displayed increased activation of both Rac and Cdc42 GTPases. Mechanistically, we uncover novel direct interactions between endogenous GPR124 and the Rho guanine nucleotide exchange factors Elmo/Dock and intersectin (ITSN). Small fragments of either Elmo or ITSN1 that bind GPR124 blocked GPR124-induced cell adhesion. In addition, Gβγ interacts with the C-terminal tail of GPR124 and promotes the formation of a GPR124-Elmo complex. Furthermore, GPR124 also promotes the activation of the Elmo-Dock complex, as measured by Elmo phosphorylation on a conserved C-terminal tyrosine residue. Interestingly, Elmo and ITSN1 also interact with each other independently of their GPR124-recognition regions. Moreover, endogenous phospho-Elmo and ITSN1 co-localize with GPR124 at lamellipodia of adhering endothelial cells, where GPR124 expression contributes to polarity acquisition during wound healing. Collectively, our results indicate that GPR124 promotes cell adhesion via Elmo-Dock and ITSN. This constitutes a previously unrecognized complex formed of atypical and conventional Rho guanine nucleotide exchange factors for Rac and Cdc42 that is putatively involved in GPR124-dependent angiogenic responses. © 2017 by The American Society for

  12. 7 CFR 945.124 - Reports.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Reports. 945.124 Section 945.124 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... address of the shipper; the car or truck identification; the loading point; destination; consignee; the...

  13. Flow effect on {sup 135}I and {sup 135}Xe evolution behavior in a molten salt reactor

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jianhui; Guo, Chen [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); Cai, Xiangzhou [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Yu, Chenggang; Zou, Chunyan [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); Han, Jianlong [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Chen, Jingen, E-mail: chenjg@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2017-04-01

    Highlights: • {sup 135}Xe and {sup 135}I evolution law in a molten salt reactor is analytically deduced. • The circulation of fuel salt through the primary loop decreases the concentration of {sup 135}I and {sup 135}Xe. • {sup 135}I and {sup 135}Xe concentration reduction is independent with the mass flow rate at normal core operating condition. • Increasing the external core volume would raise {sup 135}I and {sup 135}Xe concentration reduction caused by the flow effect. - Abstract: Molten Salt Reactor (MSR) employs fissile material dissolved in the fluoride salt as fuel which continuously circulates through the primary loop with the flow cycle time being a few tens of seconds. The nuclei evolution law is quite different from that in a solid fuel reactor. In this paper, we analytically deduce the nuclei evolution law of {sup 135}Xe and {sup 135}I which are entrained in the flowing salt, evaluate its concentration changing with the burnup time, and validate the result with the SCALE6. The circulation of fuel salt could decrease the concentration of {sup 135}Xe and {sup 135}I, and the reduction can achieve to around 40% and 50% for {sup 135}Xe and {sup 135}I respectively at a small power level (e.g., 2 MW) when the core has the same fuel salt volume as that of the outer-loop. Furthermore, it can be found that the reduction is inversely proportional to the core to outer-loop volume ratio, but uncorrelated with the mass flow rate under normal operating condition of a MSR. At low core power scale, the flow effect on {sup 135}Xe concentration reduction is apparent, but it is mitigated as the core power scale increases because of the rise of {sup 135}I concentration, which raises its decay to {sup 135}Xe and compensates the loss of {sup 135}Xe due to decay at the outer-loop. The decreased {sup 135}Xe concentration results in a core reactivity increase varying from around 150 pcm to 1000 pcm depending on the core power and core to outer-loop volume ratio.

  14. Micro RNA-124a Regulates Lipolysis via Adipose Triglyceride Lipase and Comparative Gene Identification 58

    Directory of Open Access Journals (Sweden)

    Suman K. Das

    2015-04-01

    Full Text Available Lipolysis is the biochemical pathway responsible for the catabolism of cellular triacylglycerol (TG. Lipolytic TG breakdown is a central metabolic process leading to the generation of free fatty acids (FA and glycerol, thereby regulating lipid, as well as energy homeostasis. The precise tuning of lipolysis is imperative to prevent lipotoxicity, obesity, diabetes and other related metabolic disorders. Here, we present our finding that miR-124a attenuates RNA and protein expression of the major TG hydrolase, adipose triglyceride lipase (ATGL/PNPLA2 and its co-activator comparative gene identification 58 (CGI-58/ABHD5. Ectopic expression of miR-124a in adipocytes leads to reduced lipolysis and increased cellular TG accumulation. This phenotype, however, can be rescued by overexpression of truncated Atgl lacking its 3'UTR, which harbors the identified miR-124a target site. In addition, we observe a strong negative correlation between miR-124a and Atgl expression in various murine tissues. Moreover, miR-124a regulates the expression of Atgl and Cgi-58 in murine white adipose tissue during fasting as well as the expression of Atgl in murine liver, during fasting and re-feeding. Together, these results point to an instrumental role of miR-124a in the regulation of TG catabolism. Therefore, we suggest that miR-124a may be involved in the regulation of several cellular and organismal metabolic parameters, including lipid storage and plasma FA concentration.

  15. Development of a hyperpolarized 129Xe system on 3T for the rat lungs

    International Nuclear Information System (INIS)

    Sato, Hiroshi; Enmi, Jun-ichiro; Hayashi, Takuya

    2004-01-01

    MRI (magnetic resonance imaging) with 129 Xe has gained much attention as a diagnostic methodology because of its affinity for lipids and possible polarization. The quantitative estimation of net detectability and stability of hyperpolarized 129 Xe in the dissolved phase in vivo is valuable to the development of clinical applications. The goal of this study was to develop a stable hyperpolarized 129 Xe experimental 3T system to statistically analyze the dissolved-phase 129 Xe signal in the rat lungs. The polarization of 129 Xe with buffer gases at the optical pumping cell was measured under adiabatic fast passage against the temperature of an oven and laser absorption at the cell. The gases were insuffiated into the lungs of Sprague-Dawley rats (n=15, 400-550 g) through an endotracheal tube under spontaneous respiration. Frequency-selective spectroscopy was performed for the gas phase and dissolved phase. We analyzed the 129 Xe signal in the dissolved phase to measure the chemical shift, T 2 * , delay and its ratio in a rat lungs on 3T. The polarizer was able to produce polarized gas (1.1±0.47%, 120 cm 3 ) hundreds of times with the laser absorption ratio (25%) kept constant at the cell. The optimal buffer gas ratio of 25-50% rendered the maximum signal in the dissolved phase. Two dominant peaks of 211.8±0.9 and 201.1±0.6 ppm were observed with a delay of 0.4±0.9 and 0.9±1.0 s from the gas phase spectra. The ratios of their average signal to that of the gas phase were 5.6±5.2% and 4.4±4.7%, respectively. The T 2 * of the air space in the lungs was 2.5±0.5 ms, which was 3.8 times shorter than that in a syringe. We developed a hyperpolarized 129 Xe experimental system using a 3T MRI scanner that yields sufficient volume and polarization and quantitatively analyzed the dissolved-phase 129 Xe signal in the rat lungs. (author)

  16. Positron annihilation and 129Xe NMR studies of free volume in polymers

    International Nuclear Information System (INIS)

    Nagasaka, Bunsow; Eguchi, Taro; Nakayama, Hirokazu; Nakamura, Nobuo; Ito, Yasuo

    2000-01-01

    The existence and the average size of free volume in bisphenol-A polycarbonate (PC), low-density polyethylene (LDPE), poly (2,6-dimethyl-phenylene oxide)(PPO), and polytetrafluoroethylene (PTFE) were studied by positron annihilation and 129 Xe NMR measurements. The 129 Xe NMR chemical shifts for xenon adsorbed in the polymers indicated that the average pore size of the free volume increased in the following order: PC, LDPE, PPO, and PTFE. This order of the pore size of the free volume agrees well with that estimated from the longest lifetime (τ 3 ) of ortho-positronium formed in the polymers. The unique correlation that δ -1 ∝ r is established between the 129 Xe NMR chemical shift (δ) and the pore size (r), which is deduced from the positron annihilation measurements.

  17. Double optimization of Xe(L) amplifier power scaling at λ ∼ 2.9 A

    International Nuclear Information System (INIS)

    Borisov, Alex B; Song, Xiangyang; Zhang Ping; McCorkindale, John C; Khan, Shahab F; Poopalasingam, Sankar; Zhao Ji; Dai Yang; Rhodes, Charles K

    2007-01-01

    The spectral and spatial characteristics of the Xe(L) amplifier at λ ∼ 2.9 A determine an optimum for the scaling of the peak power with channel length. The Xe 31+ and Xe 32+ (3d → 2p) transition arrays represent two identical spectral optima for amplification, a property stemming from the extremum of spectral components (3245) characteristic of their electron configurations. Adroit matching of the spatial distribution of the intensity characteristic of the propagating 248 nm pulse dynamically generating the self-trapped plasma channel with the intensity required to excite selectively and efficiently the Xe 31+ and Xe 32+ arrays can also simultaneously maximize the spatial volume of the excitation. The net outcome of this double maximization is an amplifying channel for the optimal transitions that possesses high gain (∼100 cm -1 ), low losses ( -1 cm -1 ) and a diameter of 15-20 μm, a size sufficient to produce an x-ray pulse energy of ∼50-100 mJ from a channel having an average xenon density of ∼10 20 cm -3 and a length of 1 cm. Since previous studies have experimentally demonstrated the ability to produce a saturated bandwidth of ∼60 eV, a magnitude sufficient to support a pulse duration of ∼30 as, peak powers P x >> 1 PW are clearly within the scaling limits of the Xe(L) system. The corresponding peak brightness scaling limit is accordingly bounded from below by P x /λ 2 ≅ 10 30 W cm -2 sr -1 . (fast track communication)

  18. Ar-Xe Laser: The Path to a Robust, All-Electric Shipboard Directed Energy Weapon

    National Research Council Canada - National Science Library

    Apruzese, J. P; Sethian, J. D; Giuliani, J. L; Wolford, M. F

    2008-01-01

    .... The electron beam pumped Ar-Xe laser has been investigated in an ONR-sponsored 6.1 program at NRL. The results of this program are summarized in this Memorandum Report, and indicate that the Ar-Xe laser has strong potential to meet these requirements...

  19. Striatal modulation of BDNF expression using microRNA124a-expressing lentiviral vectors impairs ethanol-induced conditioned-place preference and voluntary alcohol consumption.

    Science.gov (United States)

    Bahi, Amine; Dreyer, Jean-Luc

    2013-07-01

    Alcohol abuse is a major health, economic and social concern in modern societies, but the exact molecular mechanisms underlying ethanol addiction remain elusive. Recent findings show that small non-coding microRNA (miRNA) signaling contributes to complex behavioral disorders including drug addiction. However, the role of miRNAs in ethanol-induced conditioned-place preference (CPP) and voluntary alcohol consumption has not yet been directly addressed. Here, we assessed the expression profile of miR124a in the dorsal striatum of rats upon ethanol intake. The results show that miR124a was downregulated in the dorso-lateral striatum (DLS) following alcohol drinking. Then, we identified brain-derived neurotrophic factor (BDNF) as a direct target of miR124a. In fact, BDNF mRNA was upregulated following ethanol drinking. We used lentiviral vector (LV) gene transfer technology to further address the role of miR124a and its direct target BDNF in ethanol-induced CPP and alcohol consumption. Results reveal that stereotaxic injection of LV-miR124a in the DLS enhances ethanol-induced CPP as well as voluntary alcohol consumption in a two-bottle choice drinking paradigm. Moreover, miR124a-silencer (LV-siR124a) as well as LV-BDNF infusion in the DLS attenuates ethanol-induced CPP as well as voluntary alcohol consumption. Importantly, LV-miR124a, LV-siR124a and LV-BDNF have no effect on saccharin and quinine intake. Our findings indicate that striatal miR124a and BDNF signaling have crucial roles in alcohol consumption and ethanol conditioned reward. © 2013 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  20. Improving the efficiency of a fluorescent Xe dielectric barrier light source using short pulse excitation

    International Nuclear Information System (INIS)

    Beleznai, Sz; Mihajlik, G; Richter, P; Maros, I; Balazs, L

    2008-01-01

    Operation of a Xe dielectric barrier discharge lamp producing 147-172 nm VUV radiation is investigated both theoretically and experimentally. Xe gas pressure varies between 100 and 300 mbar, and the glass body of the lamp is coated with LAP (green) phosphor to convert radiation into the visible part of the spectrum. Simulation results predict improved discharge efficiencies reaching 67% when excited by a fast rise-time, short pulse (∼200 ns) driving waveform. In this case most power deposited into the plasma efficiently produces Xe 2 * excimers, while other energy dissipation processes (ion heating, e-Xe elastic collision) are kept at a low rate. Simulation and experimental results are compared in terms of discharge efficacy and show good agreement. A lamp efficacy value as high as 80 lm W -1 is demonstrated experimentally

  1. Differential cross sections for inelastic scattering of electrons on Kr and Xe atoms at intermediate energies

    International Nuclear Information System (INIS)

    Filipovic, D.M.

    1989-01-01

    Electron-impact excitation of the larger- number noble-gas atoms is a way of understanding excitation mechanisms in atomic collisional processes. Krypton and xenon have the largest atomic number of all the stable noble gases. Therefore, effects dependent on the size of a target atom, such as alignment and orientation of the atomic outer shell charge cloud after collisional excitation, are best observed by studying these atoms. Normalized, absolute differential cross sections (DCS's) for the lowest electronic states of Kr and Xe atoms, at intermediate energies, are the subject of this report

  2. 7 CFR 1.24 - Preservation of records.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Preservation of records. 1.24 Section 1.24 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.24 Preservation of records. Agencies shall preserve all correspondence relating to the requests it receives under this...

  3. 18 CFR 284.124 - Terms and conditions.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Terms and conditions. 284.124 Section 284.124 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION... AUTHORITIES Certain Transportation by Intrastate Pipelines § 284.124 Terms and conditions. Contracts for the...

  4. Kinetic analysis of rare gas metastable production and optically pumped Xe lasers

    Science.gov (United States)

    Demyanov, A. V.; Kochetov, I. V.; Mikheyev, P. A.; Azyazov, V. N.; Heaven, M. C.

    2018-01-01

    Optically pumped all-rare-gas lasers use metastable rare gas atoms as the lasing species in mixtures with He or Ar buffer gas. The metastables are generated in a glow discharge, and we report model calculations for the optimal production of Ne*, Ar*, Kr* and Xe*. Discharge efficiency was estimated by solving the Boltzmann equation. Laser efficiency, gain and output power of the CW optically pumped Xe laser were assessed as functions of heavier rare gas content, pressure, optical pump intensity and the optical path length. It was found that, for efficient operation the heavier rare gas content has to be of the order of one percent or less, and the total pressure—in the range 0.3-1.5 atm. Output power and specific discharge power increase approximately linearly with pump intensity over the output range from 300-500 W cm-2. Ternary mixtures Xe:Ar:He were found to be the most promising. Total laser efficiency was found to be nearly the same for pumping the 2p8 or 2p9 state, reaching 61%-70% for a pump intensity of ~720 W cm-2 when the Xe fraction was in the range 0.001 ÷ 0.01 and Ar fraction—0.1 ÷ 0.5. However, when the 2p8 state was pumped, the maximum total efficiency occurred at larger pressures than for pumping of the 2p9 state. The discharge power density required to sustain a sufficient Xe* number density was in the range of tens of watts per cubic centimeter for 50% Ar in the mixture.

  5. Depth distribution analysis of martensitic transformations in Xe implanted austenitic stainless steel

    International Nuclear Information System (INIS)

    Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Chechenin, N.G.; Grabaek, L.; Bohr, J.

    1988-01-01

    In this work we present results from a depth distribution analysis of the martensitic phase change occurring in Xe implanted single crystals of austenitic stainless steel. Analysis was done by 'in situ' RBS/channeling analysis, X-ray diffraction and cross-section transmission electron microscopy (XTEM) of the implanted surface. It is found that the martensitic transformation of the surface layer occurs for fluences above 1x10 20 m -2 . The thickness of the transformed layer increases with fluence to ≅ 150 nm at 1x10 21 m -2 , which far exceeds the range plus straggling of the implanted Xe as calculated by the TRIM computer simulation code. Simulations using the MARLOWE code indicate that the thickness of the transformed layer coincides with the range of the small fraction of ions channeled under random implantation conditions. Using cross sectional TEM on the Xe implanted crystals, the depth distribution of gas inclusions and defects can be directly observed. Using X-ray diffraction on implanted single crystals, the solid epitaxial nature of the Xe inclusions, induced prior to the martensitic transformation, was established. The lattice constant obtained from the broad diffraction peak indicates that the pressure in the inclusions is ≅ 5 GPa. (orig./BHO)

  6. Recent improvements of a mobile polarizer system for {sup 129}Xe

    Energy Technology Data Exchange (ETDEWEB)

    Stahl, Vanessa; Heil, Werner; Karpuk, Sergei; Bluemler, Peter; Repetto, Maricel; Niederlaender, Benjamin; Braun, Manuel; Fuchs, Martin [Institut fuer Physik, Universitaet Mainz (Germany); Muennemann, Kerstin; Spiess, Hans [Max Planck Institute for Polymer Research Mainz (Germany)

    2013-07-01

    (HP){sup 129}Xe has numerous applications both in fundamental physics like nuclear spin clocks and in medical research, e.g. in lung MRI. We report on a compact mobile {sup 129}Xe polarizer built in order to achieve high polarization degrees operating in counter flow. The optical pumping scheme is optimized in terms of magnetic field homogeneity, rubidium saturation, freeze-thaw method, gas-transport and its storage in special vessels with low wall relaxation. This talk will cover different aspects of HP gas production, manipulation and minimization of losses due to relaxation.

  7. Fluorine Substituted 1,2,4-Triazinones as Potential Anti-HIV-1 and CDK2 Inhibitors

    Directory of Open Access Journals (Sweden)

    Mohammed S. I. Makki

    2014-01-01

    Full Text Available Fluorine substituted 1,2,4-triazinones have been synthesized via alkylation, amination, and/or oxidation of 6-(2-amino-5-fluorophenyl-3-thioxo-3,4-dihydro-1,2,4-triazin-5(2H-one 1 and 4-fluoro-N-(4-fluoro-2-(5-oxo-3-thioxo-2,3,4,5-tetrahydro-1,2,4-triazin-6-ylphenylbenzamide 5 as possible anti-HIV-1 and CDK2 inhibitors. Alkylation on positions 2 and 4 in 1,2,4-triazinone gave compounds 6–8. Further modification was performed by selective alkylation and amination on position 3 to form compounds 9–15. However oxidation of 5 yielded compounds 16–18. Structures of the target compounds have been established by spectral analysis data. Five compounds (5, 11, 14, 16, and 17 have shown very good anti-HIV activity in MT-4 cells. Similarly, five compounds (1, 3, and 14–16 have exhibited very significant CDK2 inhibition activity. Compounds 14 and 16 were found to have dual anti-HIV and anticancer activities.

  8. MicroRNA-124 slows down the progression of Huntington′s disease by promoting neurogenesis in the striatum

    Directory of Open Access Journals (Sweden)

    Tian Liu

    2015-01-01

    Full Text Available MicroRNA-124 contributes to neurogenesis through regulating its targets, but its expression both in the brain of Huntington′s disease mouse models and patients is decreased. However, the effects of microRNA-124 on the progression of Huntington′s disease have not been reported. Results from this study showed that microRNA-124 increased the latency to fall for each R6/2 Huntington′s disease transgenic mouse in the rotarod test. 5-Bromo-2′-deoxyuridine (BrdU staining of the striatum shows an increase in neurogenesis. In addition, brain-derived neurotrophic factor and peroxisome proliferator-activated receptor gamma coactivator 1-alpha protein levels in the striatum were increased and SRY-related HMG box transcription factor 9 protein level was decreased. These findings suggest that microRNA-124 slows down the progression of Huntington′s disease possibly through its important role in neuronal differentiation and survival.

  9. Electromagnetic excitation of 136Xe in relativistic heavy ion collisions

    International Nuclear Information System (INIS)

    Schmidt, R.D.

    1991-11-01

    In the framework of the experimental program at the accelerator facilities SIS/ESR at the Society for Heavy Ion Research in Darmstadt a detector system for relativistic neutrons was developed, constructed, and applied in first experiments. An essential research aim is the study of collective states after electromagnetic excitation in relativistic heavy ion collisions. In peripheral collisions high-energy virtual photons are exchanged. This leads to the excitation of giant resonances, especially of the giant dipole and quadrupole resonance. An essential decay channel of giant resonances in heavy nuclei is the emission of neutrons, followed by the emission of γ radiation below the particle threshold. These decay channels were studied with the detector system developed by the LAND collaboration. A first experiment on the electromagnetic excitation was performed with a 136 Xe beam at an energy of 700 MeV/u and Pb respectively C targets. (orig./HSI) [de

  10. A compact 133Xe gas dispenser

    International Nuclear Information System (INIS)

    Hawkins, T.; Harris, R.

    1977-01-01

    A dispenser for 133 Xe gas is described which is compact and simple to use, allowing the xenon to be dispensed from it shipping ampoule to suitable multi-dose injection vials in a controlled manner and with a high degree of operator safety. The apparatus has no joints and only a single rubber teat, minimizing the risks of adsorption and leakage. A scaled drawing of the dispenser is shown. (U.K.)

  11. The LEU target development and conversion program for the MAPLE reactors and new processing facility

    International Nuclear Information System (INIS)

    Malkoske, G.R.

    2003-01-01

    The availability of isotope grade, Highly Enriched Uranium (HEU), from the United States for use in the manufacture of targets for molybdenum-99 production in AECL's NRU research reactor has been a key factor to enable MDS Nordion to develop a reliable, secure supply of medical isotopes for the international nuclear medicine community. The molybdenum extraction process from HEU targets is a proven and established method that has reliably produced medical isotopes for several decades. The HEU process provides predictable, consistent yields for our high-volume, molybdenum-99 production. Other medical isotopes such as I-131 and Xe-133, which play an important role in nuclear medicine applications, are also produced from irradiated HEU targets as a by-product of the molybdenum-99 process. To ensure a continued reliable and timely supply of medical isotopes, MDS Nordion is completing the commissioning of two MAPLE reactors and an associated isotope processing facility (the New Processing Facility). The new MAPLE facilities, which will be dedicated exclusively to medical isotope production, will provide an essential contribution to a secure, robust global healthcare system. Design and construction of these facilities has been based on a life cycle management philosophy for the isotope production process. This includes target irradiation, isotope extraction and waste management. The MAPLE reactors will operate with Low Enriched Uranium (LEU) fuel, a significant contribution to the objectives of the RERTR program. The design of the isotope production process in the MAPLE facilities is based on an established process - extraction of isotopes from HEU target material. This is a proven technology that has been demonstrated over more than three decades of operation. However, in support of the RERTR program and in compliance with U.S. legislation, MDS Nordion has undertaken a LEU Target Development and Conversion Program for the MAPLE facilities. This paper will provide an

  12. Investigations of an excimer laser working with a four-component gaseous mixture He-Kr:Xe-HCl

    Science.gov (United States)

    Iwanejko, Leszek; Pokora, Ludwik J.

    1991-08-01

    The paper presnts working conditions of an XCI excimer laser untypical gas mixture based on KrzXe instead of pure Xe. Such a choice was influenced by the necessity of Findin9 the way to replace imported and expensive Xe by gaseous components accesible in Poland. Determining the range of changes of laser extrnal parameters which enables its proper work with the new gas mixture was the aim of same investigations results of which are presented in this paper. The laser pulse output energy and the pulse duration as a Function of supply voltage and the mixture composition are presented. The range of proper conditions for the laser working with the new mixture He-Kr:Xe--HC1 was determined. The analysis of experimental results showed that using the new mixture ensures value of energy and pulse duration comparable with the ones obtained for the mixture He-''Xe--HCl. Spectral investigations showed the lack of influence of Kr presence in the mixture on the generation spectrum of the laser. L.

  13. High power laser interaction with single and double layer targets

    Czech Academy of Sciences Publication Activity Database

    Borodziuk, S.; Demchenko, N. N.; Gus'kov, S. Yu.; Jungwirth, Karel; Kálal, M.; Kasperczuk, A.; Kondrashov, V. N.; Králiková, Božena; Krouský, Eduard; Limpouch, Jiří; Mašek, Karel; Pisarczyk, P.; Pisarczyk, T.; Pfeifer, Miroslav; Rohlena, Karel; Rozanov, V. B.; Skála, Jiří; Ullschmied, Jiří

    2005-01-01

    Roč. 35, č. 2 (2005), s. 241-262 ISSN 0078-5466 R&D Projects: GA MŠk(CZ) LN00A100; GA AV ČR(CZ) KSK2043105 Grant - others:EU(XE) HPRI-CT-1999-00053; RFBR(RU) 02-02-16966; IAEA(XE) 11655/RBF; INTAS(XX) 01-0572 Institutional research plan: CEZ:AV0Z10100523; CEZ:AV0Z20430508 Keywords : laser produced plasma * three-frame interferometry * macroparticle * single and double targets * crater * shock wave * laser energy absorption Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.459, year: 2005

  14. Heated uranium tetrafluoride target system to release non-rare gas fission products for the TRISTAN isotope separator

    International Nuclear Information System (INIS)

    Gill, R.L.

    1977-10-01

    Off-line experiments indicated that fluorides of As, Se, Br, Kr, Zr, Nb, Mo, Tc, Ru, Sb, Te, I and Xe could be volatilized, but except for Br, Kr, I and Xe, none of these elements were observed after mass separation in the on-line experiments. The results of the on-line experiments indicated a very low level of hydride contamination at ambient temperature and consequently, uranium tetrafluoride replaced uranyl stearate as the primary gaseous fission product target. Possible reasons for the failure of the heated target system to yield non-rare gas activities are discussed and suggestions for designing a new heated target system are presented

  15. Multifragment emission times in Xe induced reactions

    Energy Technology Data Exchange (ETDEWEB)

    Moroni, A. [INFN and Dipartimento di Fisica, Via Celoria 16, 20133 Milano (Italy); Bowman, D.R. [AECL Research, Chalk River Laboratories, Chalk River, Ont. (Canada); Bruno, M. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Buttazzo, P. [Dipartimento di Fisica and INFN, Via A. Valerio 2, 34127 Trieste (Italy); Celano, L. [INFN, Via Amendola 173, 70126 Bari (Italy); Colonna, N. [INFN, Via Amendola 173, 70126 Bari (Italy); D`Agostino, M. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Dinius, J.D. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Ferrero, A. [INFN and Dipartimento di Fisica, Via Celoria 16, 20133 Milano (Italy); Fiandri, M.L. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Gelbke, K. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Glasmacher, T. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Gramegna, F. [INFN Laboratori Nazionali di Legnaro, Via Romea 4, 35020 Legnaro (Italy); Handzy, D.O. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Horn, D. [AECL Research, Chalk River Laboratories, Chalk River, Ont. (Canada); Hsi Wenchien [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Huang, M. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Iori, I. [INFN and Dipartimento di Fisica, Via Celoria 16, 20133 Milano (Italy); Lisa, M. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Lynch, W.G. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Margagliotti, G.V. [Dipartimento di Fisica and INFN, Via A. Valerio 2, 34127 Trieste (Italy); Mastinu, P.F. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Milazzo, P.M. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Montoya, C.

    1995-02-06

    Multifragment emission is studied in {sup 129}Xe+{sup nat}Cu reactions. The emission process for central collisions occurs on a time scale of similar 200fm/c at 30MeV/n. Intermediate-mass-fragment yields, velocity correlation functions and emission velocities of Z=6 fragments are compared with predictions of statistical decay models. ((orig.)).

  16. Cross section TEM characterization of high-energy-Xe-irradiated U-Mo

    Energy Technology Data Exchange (ETDEWEB)

    Ye, B., E-mail: bye@anl.gov [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States); Jamison, L.; Miao, Y. [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States); Bhattacharya, S. [Department of Materials Science and Engineering, Northwestern University, 2220 Campus Dr. Evanston, IL 60208 (United States); Hofman, G.L.; Yacout, A.M. [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States)

    2017-05-15

    U-Mo alloys irradiated with 84 MeV Xe ions to various doses were characterized with transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) techniques. The TEM thin foils were prepared perpendicular to the irradiated surface to allow a direct observation of the entire region modified by ions. Therefore, depth-selective microstructural information was revealed. Varied irradiation-induced phenomena such as gas bubble formation, phase reversal, and recrystallization were observed at different ion penetration depths in U-Mo. - Highlights: •Three distinct zones were observed along the ion traveling direction in U-7Mo irradiated with 84 MeV Xe ions at 350 °C. •The α-U particles within the Xe-implanted region were reverted to γ-U phase by irradiation. •High-density random intra-granular bubbles in a size of 4–5 nm were found in the irradiated region, coexisting with large inter-granular bubbles. •The high lattice stresses built up during the irradiation-induced phase reversal is probably the driving force for the small grain formation at cell boundaries.

  17. Compact 4-kHz XeF-laser with multisectional discharge gap

    Science.gov (United States)

    Andramanov, A. V.; Kabaev, S. A.; Lazhintsev, Boris V.; Nor-Arevyan, Vladimir A.; Selemir, V. D.

    2005-03-01

    An electric-discharge XeF-laser with a pulse repetition rate up to 4 kHz was developed. The laser electrode unit was made on the basis of plate-like electrodes with inductive-capacity discharge stabilization. The narrow discharge width laser energy was 3 mJ by using He/Xe/NF3 and Ne/Xe/NF3 mixtures at the total pressure of 0.8 atm and 1.2 atm, respectively. The maximum laser efficiency was ~ 0.73% The gas flow was formed with the help of a diametrical fan rotated by the direct-current motor with 80 W power. The gas velocity of 20 m/s in the interelectrode gap was achieved. The laser pulse energy for a pulse repetition rate up to 3.5...4 kHz was virtually equal to the laser pulse energy in the infrequently-repeating-pulse regime. The average output power of 12 W at the pulse repetition rate of 4 kHz was achieved. The relative root-mean-square pulse-to-pulse variation of the output energy σ = 2.5% was reached.

  18. Evolution of Xe spectrum and ion charge under sudden incoming radiation

    Science.gov (United States)

    Klapisch, Marcel; Busquet, Michel

    2012-06-01

    Experiments [1] and simulations of Xe at high temperature were recently reported, due to the possible scaling of astrophysical radiative shocks [2]. We used the newest version of HULLAC [3] to compute energy levels, radiative and collisional transition rates and level populations in a Coronal Radiative Model for the ions Xe9+ to Xe44+ (36263 configurations), at electron temperature of 100 eV and electron density of 10^19 -- 10^21 e/cm^3, in the presence of an external Planckian radiation field. Static and time dependent influence of the radiation on ion charge and spectrum is described. We show an effect of shell structure on relaxation of ion charge when the radiation field is suddenly turn on.[4pt] [1] Busquet, M., Thais, F., Gonzalez, M., et al., J. App. Phys. 107, 083302 (2010).[0pt] [2] Ryutov, D., Drake, R. P., Kane, J., et al., Astrophys. J. 518, 821 (1999).[0pt] [3] Klapisch, M. and Busquet, M., High Ener. Dens. Phys. 7, 98 (2011).

  19. Labeling and quality control of 123I-MIBG

    International Nuclear Information System (INIS)

    Figols de Barboza, Marycel Rosa

    2002-01-01

    This report describes a method to facilitate routine production of 123 I-MIBG in Radiopharmacy Centre of IPEN-CNEN/SP. Iodine-123 radioisotope is produced in the form of sodium iodide in Cyclone-30 (IBA) at IPEN-CNEN/SP through proton irradiation of gaseous 124 Xe target. The labelling procedure uses MIBG-sulphate and leads to 123 I-MIBG with radiochemical purity at least 98% and specific activity of 300-380 MBq/mg

  20. Regional cerebral blood flow measurements using noninvasive 133Xe clearance method in children

    International Nuclear Information System (INIS)

    Nishimoto, Hiroshi; Maeda, Koji; Kagawa, Yukihide; Morozumi, Kunihiko; Hashimoto, Manami; Tsubokawa, Takashi.

    1985-01-01

    The noninvasive 133-Xe clearance method of estimating rCBF has been widely used in adult clinical studies. It is safe, noninvasive and reproducible, and has provided valuable insight into adult cerebrovascular pathophysiology. However, in children, this technique has not been used to measure rCBF for some fundamental problems. This study was performed to clarify these fundamental problems for applications of noninvasive 133-Xe clearance technique to children. The results showed that three fundamental problems concerning; (1) volume of dead spaces in airway circuits of the system, (2) increasing of look-through phenomenon and (3) correction methods for recirculated 133-Xe and airway artifacts to estimate rCBF are important for applications to children. These problems should be improved to measure as correct rCBF in children as in adults. (author)

  1. Synthesis and X-ray crystal structure of (OsO(3)F(2))(2)2XeOF(4) and the Raman spectra of (OsO(3)F(2))(infinity), (OsO(3)F(2))(2), and (OsO(3)F(2))(2)2XeOF(4).

    Science.gov (United States)

    Hughes, Michael J; Mercier, Hélène P A; Schrobilgen, Gary J

    2009-05-18

    The adduct, (OsO(3)F(2))(2)2XeOF(4), was synthesized by dissolution of the infinite chain polymer, (OsO(3)F(2))(infinity), in XeOF(4) solvent at room temperature followed by removal of excess XeOF(4) under dynamic vacuum at 0 degrees C. Continued pumping at 0 degrees C resulted in removal of associated XeOF(4), yielding (OsO(3)F(2))(2), a new low-temperature phase of OsO(3)F(2). Upon standing at 25 degrees C for 1(1)/(2) h, (OsO(3)F(2))(2) underwent a phase transition to the known monoclinic phase, (OsO(3)F(2))(infinity). The title compounds, (OsO(3)F(2))(infinity), (OsO(3)F(2))(2), and (OsO(3)F(2))(2)2XeOF(4) have been characterized by low-temperature (-150 degrees C) Raman spectroscopy. Crystallization of (OsO(3)F(2))(2)2XeOF(4) from XeOF(4) solution at 0 degrees C yielded crystals suitable for X-ray structure determination. The structural unit contains the (OsO(3)F(2))(2) dimer in which the OsO(3)F(3) units are joined by two Os---F---Os bridges having fluorine bridge atoms that are equidistant from the osmium centers (2.117(5) and 2.107(4) A). The dimer coordinates to two XeOF(4) molecules through Os-F...Xe bridges in which the Xe...F distances (2.757(5) A) are significantly less than the sum of the Xe and F van der Waals radii (3.63 A). The (OsO(3)F(2))(2) dimer has C(i) symmetry in which each pseudo-octahedral OsO(3)F(3) unit has a facial arrangement of oxygen ligands with XeOF(4) molecules that are only slightly distorted from their gas-phase C(4v) symmetry. Quantum-chemical calculations using SVWN and B3LYP methods were employed to calculate the gas-phase geometries, natural bond orbital analyses, and vibrational frequencies of (OsO(3)F(2))(2), (OsO(3)F(2))(2)2XeOF(4), XeOF(4), OsO(2)F(4), and (mu-FOsO(3)F(2))(2)OsO(3)F(-) to aid in the assignment of the experimental vibrational frequencies of (OsO(3)F(2))(2), (OsO(3)F(2))(2)2XeOF(4), and (OsO(3)F(2))(infinity). The vibrational modes of the low-temperature polymeric phase, (OsO(3)F(2))(infinity), have been

  2. Multifragmentation in intermediate energy 129Xe-induced heavy-ion reactions

    International Nuclear Information System (INIS)

    Tso, Kin.

    1996-05-01

    The 129 Xe-induced reactions on nat Cu, 89 Y, 165 Ho, and 197 Au at bombarding energies of E/A = 40 ampersand 60 MeV have been studied theoretically and experimentally in order to establish the underlying mechanism of multifragmentation at intermediate energy heavy-Ion collisions. Nuclear disks formed in central heavy-ion collisions, as simulated by means of Boltzmann-like kinetic equations, break up into several fragments due to a new kind of Rayleigh-like surface instability. A sheet of liquid, stable in the limit of non-interacting surfaces, is shown to become unstable due to surface-surface interactions. The onset of this instability is determined analytically. A thin bubble behaves like a sheet and is susceptible to the surface instability through the crispation mode. The Coulomb effects associated with the depletion of charges in the central cavity of nuclear bubbles are investigated. The onset of Coulomb instability is demonstrated for perturbations of the radial mode. Experimental intermediate-mass-fragment multiplicity distributions for the 129 Xe-induced reactions are shown to be binomial at each transverse energy. From these distributions, independent of the specific target, an elementary binary decay probability p can be extracted that has a thermal dependence. Thus it is inferred that multifragmentation is reducible to a combination of nearly independent emission processes. If sequential decay is assumed, the increase of p with transverse energy implies a contraction of the emission time scale. The sensitivity of p to the lower Z threshold in the definition of intermediate-mass-fragments points to a physical Poisson simulations of the particle multiplicities show that the weak auto-correlation between the fragment multiplicity and the transverse energy does not distort a Poisson distribution into a binomial distribution. The effect of device efficiency on the experimental results has also been studied

  3. Multifragmentation in 30 MeV/u [sup 129]Xe induced reactions

    Energy Technology Data Exchange (ETDEWEB)

    Colonna, N. (INFN, Bari (Italy)); Bowman, D.R. (Chalk River Lab. (Canada)); Brambilla, S. (Dipt. di Fisica and INFN, Milan (Italy)); Bruno, M. (Dipt. di Fisica and INFN, Bologna (Italy)); Buttazzo, P. (Dipt. di Fisica and INFN, Trieste (Italy)); Celano, L. (INFN, Bari (Italy)); Chiodini, S. (Dipt. di Fisica and INFN, Milan (Italy)); D' Agostino, M. (Dipt. di Fisica and INFN, Bologna (Italy)); Dinius, J.D. (Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.); Ferrero, A. (Dipt. di Fisica and INFN, Milan (Italy)); Gelbke, K. (Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.); Glasmacher, T. (Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.); Gramegna, F. (INFN, Lab. Nazionali, Legnaro (Italy)); Handzy, D.O. (Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.); Horn, D. (Chalk River Lab. (Canad

    1994-01-01

    Multifragmentation processes in the 30 MeV/u [sup 129]Xe + [sup nat]Cu and [sup 129]Xe + [sup 197]Au reactions were studied with a low threshold, high-granularity 4[pi] detection system. Fragment velocity distributions have been measured at forward angles as a function of the total charged particle multiplicity. While a two-source pattern is observed for the peripheral collisions, no evidence of a dinuclear emission pattern is found for the most central collisions. Kinematical observables, such as fragment relative velocity, relative angle and reduced velocity correlation functions indicate a fast timescale of the multifragmentation process in these reactions. (orig.)

  4. Probing zeolite internal structures using very low temperature 129Xe NMR

    International Nuclear Information System (INIS)

    Labouriau, A.; Crawford, S.N.; Earl, W.L.; Pietrass, T.; Weber, W.A.; Panjabi, G.; Gates, B.C.

    1998-01-01

    In recent years, probing pore structure with 129 Xe NMR has received a bad reputation. This is due to the fact that the method is more complex than was originally suggested so the data is somewhat difficult to interpret. The authors find that the use of a wide temperature range (40--350 K) allows them to interpret 129 Xe chemical shifts in terms of van der Waals attraction between the xenon atom and oxygen in zeolite walls. Using rather simple models from the literature, they can extract useful pore size information as well as the van der Waals potential energy

  5. Probing the porosity of cocrystallized MCM-49/ZSM-35 zeolites by hyperpolarized 129Xe NMR.

    Science.gov (United States)

    Liu, Yong; Zhang, Weiping; Xie, Sujuan; Xu, Longya; Han, Xiuwen; Bao, Xinhe

    2008-01-31

    One- and two-dimensional 129Xe NMR spectroscopy has been employed to study the porosity of cocrystallized MCM-49/ZSM-35 zeolites under the continuous flow of hyperpolarized xenon gas. It is found by variable-temperature experiments that Xe atoms can be adsorbed in different domains of MCM-49/ZSM-35 cocrystallized zeolites and the mechanically mixed counterparts. The exchange of Xe atoms in different types of pores is very fast at ambient temperatures. Even at very low temperature two-dimensional exchange spectra (EXSY) show that Xe atoms still undergo much faster exchange between MCM-49 and ZSM-35 analogues in the cocrystallized zeolites than in the mechanical mixture. This demonstrates that the MCM-49 and ZSM-35 analogues in cocrystallized zeolites may be stacked much closer than in the physical mixture, and some parts of intergrowth may be formed due to the partially similar basic structure of MCM-49 and ZSM-35.

  6. Stable isotope enrichment: Current and future potential

    International Nuclear Information System (INIS)

    Tracy, J.G.; Aaron, W.S.

    1992-01-01

    Oak Ridge National Laboratory (ORNL) operates the Isotope Enrichment Facility for the purpose of providing enriched stable isotopes, selected radioactive isotopes (including the actinides), and isotope-related materials and services for use in various research applications. ORNL is responsible for isotope enrichment and the distribution of approximately 225 nongaseous stable isotopes from 50 multi-isotopic elements. Many enriched isotope products are of prime importance in the fabrication of nuclear targets and the subsequent production of special radionuclides. State-of-the-art techniques to achieve special isotopic, chemical, and physical requirements are performed at ORNL This report describes the status and capabilities of the Isotope Enrichment Facility and the Isotope Research Materials Laboratory as well as emphasizing potential advancements in enrichment capabilities

  7. Stable isotope enrichment - current and future potential

    International Nuclear Information System (INIS)

    Tracy, J.G.; Aaron, W.S.

    1993-01-01

    Oak Ridge National Laboratory (ORNL) operates the Isotope Enrichment Facility for the purpose of providing enriched stable isotopes, selected radioactive isotopes (including the actinides), and isotope-related materials and services for use in various research applications. ORNL is responsible for isotope enrichment and the distribution of approximately 225 nongaseous stable isotopes from 50 multi-isotopic elements. Many enriched isotope products are of prime importance in the fabrication of nuclear targets and the subsequent production of special radionuclides. State-of-the-art techniques to achieve special isotopic, chemical, and physical requirements are performed at ORNL. This report describes the status and capabilities of the Isotope Enrichment Facility and the Isotope Research Materials Laboratory as well as emphasizing potential advancements in enrichment capabilities. (orig.)

  8. Differential and integral cross sections in OH(X) + Xe collisions

    Energy Technology Data Exchange (ETDEWEB)

    Sarma, Gautam; Saha, Ashim Kumar; Meulen, J. J. ter; Parker, David H., E-mail: parker@science.ru.nl [Institute for Molecules and Materials, Radboud University Nijmegen, Heijendaalseweg 135, 6525 ED Nijmegen (Netherlands); Marinakis, Sarantos, E-mail: s.marinakis@qmul.ac.uk [School of Biological and Chemical Sciences, Queen Mary University of London, Joseph Priestley Building, Mile End Road, London E1 4NS (United Kingdom)

    2015-01-21

    Differential cross sections (DCSs) for inelastic collisions of OH(X) with Xe have been measured at a collision energy of 483 cm{sup −1}. The hydroxyl (OH) radicals were initially prepared in the X{sup 2}Π{sub 3/2} (v = 0, j = 1.5, f) level using the hexapole electric field selection method. Products were detected state-selectively by [2 + 1] resonance-enhanced multiphoton ionization of OH, combined with velocity-map imaging. Integral cross sections in OH(X) + Xe at a collision energy of 490 cm{sup −1} were also measured by laser-induced fluorescence. The results are compared with exact close-coupling quantum mechanical scattering calculations on the only available ab initio potential energy surface (PES). The agreement between experimental and theoretical results is generally very satisfactory. This highlights the ability of such measurements to test the available PES for such a benchmark open-shell system. The agreement between experiment and theory for DCSs is less satisfactory at low scattering angles, and possible reasons for this disagreement are discussed. Finally, theoretical calculations of OH(X) + He DCSs have been obtained at various collision energies and are compared with those of OH(X) + Xe. The role of the reduced mass in the DCSs and partial cross sections is also examined.

  9. Differential and integral cross sections in OH(X) + Xe collisions

    International Nuclear Information System (INIS)

    Sarma, Gautam; Saha, Ashim Kumar; Meulen, J. J. ter; Parker, David H.; Marinakis, Sarantos

    2015-01-01

    Differential cross sections (DCSs) for inelastic collisions of OH(X) with Xe have been measured at a collision energy of 483 cm −1 . The hydroxyl (OH) radicals were initially prepared in the X 2 Π 3/2 (v = 0, j = 1.5, f) level using the hexapole electric field selection method. Products were detected state-selectively by [2 + 1] resonance-enhanced multiphoton ionization of OH, combined with velocity-map imaging. Integral cross sections in OH(X) + Xe at a collision energy of 490 cm −1 were also measured by laser-induced fluorescence. The results are compared with exact close-coupling quantum mechanical scattering calculations on the only available ab initio potential energy surface (PES). The agreement between experimental and theoretical results is generally very satisfactory. This highlights the ability of such measurements to test the available PES for such a benchmark open-shell system. The agreement between experiment and theory for DCSs is less satisfactory at low scattering angles, and possible reasons for this disagreement are discussed. Finally, theoretical calculations of OH(X) + He DCSs have been obtained at various collision energies and are compared with those of OH(X) + Xe. The role of the reduced mass in the DCSs and partial cross sections is also examined

  10. 7 CFR 966.124 - Approved receiver.

    Science.gov (United States)

    2010-01-01

    ... limited to, the following information: (1) Name, address, contact person, telephone number, and e-mail... 7 Agriculture 8 2010-01-01 2010-01-01 false Approved receiver. 966.124 Section 966.124 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements...

  11. Validation of Folate-Enriched Eggs as a Functional Food for Improving Folate Intake in Consumers.

    Science.gov (United States)

    Altic, Leslie; McNulty, Helene; Hoey, Leane; McAnena, Liadhan; Pentieva, Kristina

    2016-11-30

    Functional foods enriched with folate may be beneficial as a means of optimizing folate status in consumers. We recently developed novel eggs enriched with folate through folic acid supplementation of the hen's feed, but their potential to influence consumer folate status is unknown because the natural folate forms incorporated into the eggs may not necessarily be retained during storage and cooking. This study aimed to determine the stability of natural folates in folate-enriched eggs under typical conditions of storage and cooking. Total folate was determined by microbiological assay following tri-enzyme treatment in folate-enriched eggs and un-enriched (barn and free-range) on the day they were laid, after storage (up to 27 days) and after using four typical cooking methods (boiling, poaching, frying, scrambling) for different durations. On the day of laying, the folate content of enriched eggs was found to be significantly higher than that of un-enriched barn or free-range eggs (mean ± SD; 123.2 ± 12.4 vs. 41.2 ± 2.8 vs. 65.6 ± 18.5 µg/100 g; p functional foods with enriched folate content. Further studies will confirm their effectiveness in optimizing the biomarker folate status of consumers.

  12. Investigation of 123I production using electron accelerator

    International Nuclear Information System (INIS)

    Avetisyan, Albert; Avagyan, Robert; Dallakyan, Ruben; Avdalyan, Gohar; Dobrovolsky, Nikolay; Gavalyan, Vasak; Kerobyan, Ivetta; Harutyunyan, Gevorg

    2017-01-01

    The possibility of 123 I isotope production with the help of the high-intensity bremsstrahlung photons produced by the electron beam of the LUE50 linear electron accelerator at the A.I. Alikhanyan National Science Laboratory (Yerevan Physics Institute [YerPhI]) is considered. The production method has been established and shown to be successful. The 124 Xe(γ,n) 123 Xe → 123 I nuclear reaction has been investigated and the cross-section was calculated by nuclear codes TALYS 1.6 and EMPIRE 3.2. The optimum parameter of the thickness of the target was determined by GEANT4 code. For the normalized yield of 123 I, the value of 143 Bq/(mg·μA·h) has been achieved.

  13. Enhancement of molecular NMR signal induced by polarization transfer from laser-polarized 129Xe

    International Nuclear Information System (INIS)

    Sun Xianping

    2001-01-01

    There is a large non-equilibrium nuclear polarization and a longer relaxation time in the laser-polarized 129 Xe produced by means of optical pumping and spin exchange. The characteristics of the laser-polarized 129 Xe permit the transfer of the polarization to enhance the atomic nuclear spin in liquid, solid and surface of solid molecules. Therefore, the sensitivity in nuclear magnetic resonance measurements for the molecules is enhanced and applications in the investigations of materials and surface sciences are expanded. The progress in the investigations of materials and surface sciences are expanded. The progress in the investigations of the polarization transfer between laser-polarized 129 Xe and the atomic nuclei in the molecules, the relative physics and the measurement of some parameters are introduced

  14. Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging.

    Science.gov (United States)

    Kaushik, S Sivaram; Freeman, Matthew S; Cleveland, Zackary I; Davies, John; Stiles, Jane; Virgincar, Rohan S; Robertson, Scott H; He, Mu; Kelly, Kevin T; Foster, W Michael; McAdams, H Page; Driehuys, Bastiaan

    2013-09-01

    Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images exhibited intensity gradients that favored the dependent lung. To quantitatively corroborate this finding, we developed an interleaved, three-dimensional radial sequence to image the gaseous and dissolved 129Xe distributions in the same breath. These images were normalized and divided to calculate "129Xe gas-transfer" maps. We hypothesized that, for healthy volunteers, 129Xe gas-transfer maps would retain the previously observed posture-dependent gradients. This was tested in nine subjects: when the subjects were supine, 129Xe gas transfer exhibited a posterior-anterior gradient of -2.00 ± 0.74%/cm; when the subjects were prone, the gradient reversed to 1.94 ± 1.14%/cm (P exchange caused by differences in lung inflation and posture.

  15. 17 CFR 256.124 - Other investments.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Other investments. 256.124... COMPANY ACT OF 1935 2. Investments § 256.124 Other investments. This account shall include the cost or current value of investments, whichever is less, in securities, club memberships, associations, life...

  16. Synthesis and antimicrobial activity of chromone-linked 2-pyridone fused with 1,2,4-triazoles, 1,2,4-triazines and 1,2,4-triazepines ring systems

    International Nuclear Information System (INIS)

    Ali, Tarik El-Sayed; Ibrahim, Magdy Ahmed

    2010-01-01

    Three series of novel fused nitrogen heterocyclic systems such as 1,2,4-triazolo[1,5-a ] pyridines (5-7 and 9), pyrido[1,2-b][1,2,4]triazines (10, 11, 13 and 15), and pyrido[1,2-b][1,2,4]triazepines (17, 18, 20 and 22) linked with a chromone moiety were synthesized from the key intermediate 1,6-diamino-(6-chloro-4-oxo-4H-chromen-3-yl)-2-oxo-1,2-dihydropyridine-3,5- dicarbonitrile (4) with some electrophilic reagents. The structures of the novel compounds were established by elemental analyses and spectral data. All the products were also screened in vitro for their antimicrobial activity. Compounds 7, 9 and 15 showed the highest activities when compared with the reference drugs. (author)

  17. Experimental studies of self-suppression of vacuum ultraviolet generation in Xe

    International Nuclear Information System (INIS)

    Judish, J.P.; Allman, S.L.; Garrett, W.R.; Payne, M.G.

    1988-11-01

    Vacuum ultraviolet light in the range 116 nm to 117 nm was produced by using a two-photon resonant four-wave mixing scheme in Xe. The buildup of coherent cancellation of the two-photon resonant transition employed in the generation of the vacuum ultraviolet, with resulting limitations imposed on the achievable vacuum ultraviolet intensity was investigated. Under certain predicted conditions, increases in the intensity of one of the pumping beams, ∼1500 nm infrared, or tuning this beam towards resonance with the 5p 5 7s(3/2) 1 level of Xe led, not to increases, but decreases in the vacuum ultraviolet generated. 3 refs., 3 figs

  18. Electrical and chemical properties of XeCl*(308 nm) exciplex lamp created by a dielectric barrier discharge

    International Nuclear Information System (INIS)

    Baadj, S.; Harrache, Z.; Belasri, A.

    2013-01-01

    The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl 2 mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl 2 percentage in the Xe/Cl 2 gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionic processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp

  19. Electrical and chemical properties of XeCl*(308 nm) exciplex lamp created by a dielectric barrier discharge

    Science.gov (United States)

    Baadj, S.; Harrache, Z.; Belasri, A.

    2013-12-01

    The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl2 mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl2 percentage in the Xe/Cl2 gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionic processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp.

  20. 9 CFR 124.33 - Standard of due diligence.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Standard of due diligence. 124.33 Section 124.33 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... Diligence Petitions § 124.33 Standard of due diligence. (a) In determining the due diligence of an applicant...

  1. Radiopharmacology of inhaled 133Xe in skeletal sites containing deposits of Gaucher cells

    International Nuclear Information System (INIS)

    Castronovo, F.P. Jr.; McKusick, K.A.; Doppelt, S.H.; Barton, N.W.

    1993-01-01

    Gaucher's disease is a lysomal storage disease in which cells of the reticuloendothelial system accumulate the lipid glucocerebroside. It is characterized by slowly progressive visceral and osseous involvement. One of the latter manifestations includes lipid infiltration of bone marrow. We monitored the rate of the inhaled 133 Xe uptake and wash-out over diseased and normal metaphyseal and epiphyseal areas of the knee. Twenty-two patients (15 adults, 7 children) with various degrees of previously diagnosed Gaucher's disease were positioned supine under a γ-camera interfaced to a computer system. All patients rebreathed 133 Xe gas from a closed system for 10 min followed by 14 min of wash-out. Digitized images of the lung, liver, spleen, bony sites and soft tissue were obtained at 1 min intervals during the wash-in and wash-out phases. Counts for each ROI were normalized per 100 pixels and plotted as a function (time). Maximum uptake was also calculated by relating the counts/ROI/100 pixels to the 10 min integrated lung count during equilibrium (the administered ''dose''). There was essentially no 133 Xe uptake in liver and spleen involved with Gaucher's disease. Monophasic uptake and biphasic wash-out curves were observed in the limited investigative population. Gaucher deposits released the 133 Xe at a greater rate relative to soft tissue. (Author)

  2. Comprehensive assessment of sequence variation within the copy number variable defensin cluster on 8p23 by target enriched in-depth 454 sequencing

    Directory of Open Access Journals (Sweden)

    Zhang Xinmin

    2011-05-01

    Full Text Available Abstract Background In highly copy number variable (CNV regions such as the human defensin gene locus, comprehensive assessment of sequence variations is challenging. PCR approaches are practically restricted to tiny fractions, and next-generation sequencing (NGS approaches of whole individual genomes e.g. by the 1000 Genomes Project is confined by an affordable sequence depth. Combining target enrichment with NGS may represent a feasible approach. Results As a proof of principle, we enriched a ~850 kb section comprising the CNV defensin gene cluster DEFB, the invariable DEFA part and 11 control regions from two genomes by sequence capture and sequenced it by 454 technology. 6,651 differences to the human reference genome were found. Comparison to HapMap genotypes revealed sensitivities and specificities in the range of 94% to 99% for the identification of variations. Using error probabilities for rigorous filtering revealed 2,886 unique single nucleotide variations (SNVs including 358 putative novel ones. DEFB CN determinations by haplotype ratios were in agreement with alternative methods. Conclusion Although currently labor extensive and having high costs, target enriched NGS provides a powerful tool for the comprehensive assessment of SNVs in highly polymorphic CNV regions of individual genomes. Furthermore, it reveals considerable amounts of putative novel variations and simultaneously allows CN estimation.

  3. 21 CFR 133.124 - Cold-pack cheese food.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Cold-pack cheese food. 133.124 Section 133.124 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD... Cheese and Related Products § 133.124 Cold-pack cheese food. (a)(1) Cold-pack cheese food is the food...

  4. Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer

    Science.gov (United States)

    Campuzano-Zuluaga, Germán; Álvarez-Sánchez, Gonzalo; Escobar-Gallo, Gloria Elcy; Valencia-Zuluaga, Luz Marina; Ríos-Orrego, Alexandra Marcela; Pabón-Vidal, Adriana; Miranda-Arboleda, Andrés Felipe; Blair-Trujillo, Silvia; Campuzano-Maya, Germán

    2010-01-01

    Thick film, the standard diagnostic procedure for malaria, is not always ordered promptly. A failsafe diagnostic strategy using an XE-2100 analyzer is proposed, and for this strategy, malaria diagnostic models for the XE-2100 were developed and tested for accuracy. Two hundred eighty-one samples were distributed into Plasmodium vivax, P. falciparum, and acute febrile syndrome groups for model construction. Model validation was performed using 60% of malaria cases and a composite control group of samples from AFS and healthy participants from endemic and non-endemic regions. For P. vivax, two observer-dependent models (accuracy = 95.3–96.9%), one non–observer-dependent model using built-in variables (accuracy = 94.7%), and one non–observer-dependent model using new and built-in variables (accuracy = 96.8%) were developed. For P. falciparum, two non–observer-dependent models (accuracies = 85% and 89%) were developed. These models could be used by health personnel or be integrated as a malaria alarm for the XE-2100 to prompt early malaria microscopic diagnosis. PMID:20207864

  5. Separation of Kr-Xe system by thermal diffusion method

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Numata, Kazuyoshi; Matsuda, Yuji; Ouchi, Misao; Naruse, Yuji

    1979-11-01

    Separation experiments of Kr-Xe system were carried out to study the possibility of adapting thermal diffusion method for concentration of krypton in a fuel reprocessing off-gas treatment process. The results are as follows. (1) A batchwise thermal diffusion column of hot tube diameter 21 mm, cold tube diameter 32 mm, effective hight 1000 mm and volume -- 500 CC is the best in separation characteristics and in ease of operation under the different conditions. (2) The overall separation factor increases with increase of the operating temperature in the column with and without reservoir. (3) The optimum operating pressure (about 400 Torr) is independent of the operating conditions such as temperature, reservoir volume and feed gas content. (4) A preliminary design of the Kr-Xe separating plant for a reprocessing plant (1500 ton-U/yr) shows the required number of columns and the total electric power. (author)

  6. 9 CFR 124.42 - Hearing procedure.

    Science.gov (United States)

    2010-01-01

    ... Diligence Hearing § 124.42 Hearing procedure. (a) The presiding officer shall be appointed by the... hearing. (g) The due diligence hearing will be conducted in accordance with rules of practice adopted for... opportunity to participate as a party in the hearing. The standard of due diligence set forth in § 124.33 will...

  7. WE-AB-202-06: Correlating Lung CT HU with Transformation-Based and Xe-CT Derived Ventilation

    International Nuclear Information System (INIS)

    Du, K; Patton, T; Bayouth, J; Reinhardt, J; Christensen, G

    2016-01-01

    Purpose: Regional lung ventilation is useful to reduce radiation-induced function damage during lung cancer radiation therapy. Recently a new direct HU (Hounsfield unit)-based method was proposed to estimate the ventilation potential without image registration. The purpose of this study is to examine if there is a functional dependence between HU values and transformation-based or Xe-CT derived ventilation. Methods: 4DCT images acquired from 13 patients prior to radiation therapy and 4 mechanically ventilated sheep subjects which also have associated Xe-CT images were used for this analysis. Transformation-based ventilation was computed using Jacobian determinant of the transformation field between peak-exhale and peak-inhale 4DCT images. Both transformation and Xe-CT derived ventilation was computed for each HU bin. Color scatter plot and cumulative histogram were used to compare and validate the direct HU-based method. Results: There was little change of the center and shape of the HU histograms between free breathing CT and 4DCT average, with or without smoothing, and between the repeated 4DCT scans. HU of −750 and −630 were found to have the greatest transformation-based ventilation for human and sheep subjects, respectively. Maximum Xe-CT derived ventilation was found to locate at HU of −600 in sheep subjects. The curve between Xe-CT ventilation and HU was noisy for tissue above HU −400, possibly due to less intensity change of Xe gas during wash-out and wash-in phases. Conclusion: Both transformation-based and Xe-CT ventilation demonstrated that lung tissues with HU values in the range of (-750, −600) HU have the maximum ventilation potential. The correlation between HU and ventilation suggests that HU might be used to help guide the ventilation calculation and make it more robust to noise and image registration errors. Research support from NIH grants CA166703 and CA166119 and a gift from Roger Koch.

  8. WE-AB-202-06: Correlating Lung CT HU with Transformation-Based and Xe-CT Derived Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Du, K; Patton, T; Bayouth, J [University of Wisconsin, Madison, WI (United States); Reinhardt, J; Christensen, G [The University of Iowa, Iowa City, IA (United States)

    2016-06-15

    Purpose: Regional lung ventilation is useful to reduce radiation-induced function damage during lung cancer radiation therapy. Recently a new direct HU (Hounsfield unit)-based method was proposed to estimate the ventilation potential without image registration. The purpose of this study is to examine if there is a functional dependence between HU values and transformation-based or Xe-CT derived ventilation. Methods: 4DCT images acquired from 13 patients prior to radiation therapy and 4 mechanically ventilated sheep subjects which also have associated Xe-CT images were used for this analysis. Transformation-based ventilation was computed using Jacobian determinant of the transformation field between peak-exhale and peak-inhale 4DCT images. Both transformation and Xe-CT derived ventilation was computed for each HU bin. Color scatter plot and cumulative histogram were used to compare and validate the direct HU-based method. Results: There was little change of the center and shape of the HU histograms between free breathing CT and 4DCT average, with or without smoothing, and between the repeated 4DCT scans. HU of −750 and −630 were found to have the greatest transformation-based ventilation for human and sheep subjects, respectively. Maximum Xe-CT derived ventilation was found to locate at HU of −600 in sheep subjects. The curve between Xe-CT ventilation and HU was noisy for tissue above HU −400, possibly due to less intensity change of Xe gas during wash-out and wash-in phases. Conclusion: Both transformation-based and Xe-CT ventilation demonstrated that lung tissues with HU values in the range of (-750, −600) HU have the maximum ventilation potential. The correlation between HU and ventilation suggests that HU might be used to help guide the ventilation calculation and make it more robust to noise and image registration errors. Research support from NIH grants CA166703 and CA166119 and a gift from Roger Koch.

  9. Electrical and chemical properties of XeCl*(308 nm) exciplex lamp created by a dielectric barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Baadj, S.; Harrache, Z., E-mail: zharrache@yahoo.com; Belasri, A. [Université des Sciences et de la Technologie d’Oran, USTO-MB, Laboratoire de Physique des Plasmas, Matériaux Conducteurs et leurs Application (LPPMCA) (Algeria)

    2013-12-15

    The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl{sub 2} mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl{sub 2} percentage in the Xe/Cl{sub 2} gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionic processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp.

  10. Influence of the chlorine concentration on the radiation efficiency of a XeCl exciplex lamp

    Energy Technology Data Exchange (ETDEWEB)

    Avtaeva, S. V., E-mail: s_avtaeva@mail.ru [Kyrgyz-Russian Slavic University (Kyrgyzstan); Sosnin, E. A. [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation); Saghi, B. [Mohamed Boudiaf University of Sciences and Technology, Department of Electronics (Algeria); Panarin, V. A. [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation); Rahmani, B. [Mohamed Boudiaf University of Sciences and Technology, Department of Electronics (Algeria)

    2013-09-15

    The influence of the chlorine concentration on the radiation efficiency of coaxial exciplex lamps (excilamps) excited by a dielectric barrier discharge (DBD) in binary Xe-Cl{sub 2} mixtures at pressures of 240–250 Torr is investigated experimentally and theoretically. The experiments were carried out at Cl{sub 2} concentrations in the range of 0.01–1%. The DBD characteristics were calculated in the framework of a one-dimensional hydrodynamic model at Cl{sub 2} concentrations in the range of 0.1–5%. It is found that the radiation intensities of the emission bands of Xe*{sub 2}(172 nm) and XeCl* (308 nm) are comparable when the chlorine concentration in the mixture is in the range of 0.01–0.1%. In this case, in the mixture, the radiation intensity of the Xe*{sub 2} molecule rapidly decreases with increasing Cl{sub 2} concentration and, at a chlorine concentration of ≥0.2%, the radiation of the B → X band of XeCl* molecules with a peak at 308 nm dominates in the discharge radiation. The radiation efficiency of this band reaches its maximum value at chlorine concentrations in the range of 0.4–0.5%. The calculated efficiencies of DBD radiation exceed those obtained experimentally. This is due to limitations of the one-dimensional model, which assumes the discharge to be uniform in the transverse direction, whereas the actual excilamp discharge is highly inhomogeneous. The influence of the chlorine concentration on the properties of the DBD plasma in binary Xe-Cl{sub 2} mixtures is studied numerically. It is shown that an increase in the Cl{sub 2} concentration in the mixture leads to the attachment of electrons to chlorine atoms and a decrease in the electron density and discharge conductivity. As a result, the electric field and the voltage drop across the discharge gap increase, which, in turn, leads to an increase in the average electron energy and the probability of dissociation of Cl{sub 2} molecules and ionization of Xe atoms and Cl{sub 2} molecules

  11. Influence of the chlorine concentration on the radiation efficiency of a XeCl exciplex lamp

    International Nuclear Information System (INIS)

    Avtaeva, S. V.; Sosnin, E. A.; Saghi, B.; Panarin, V. A.; Rahmani, B.

    2013-01-01

    The influence of the chlorine concentration on the radiation efficiency of coaxial exciplex lamps (excilamps) excited by a dielectric barrier discharge (DBD) in binary Xe-Cl 2 mixtures at pressures of 240–250 Torr is investigated experimentally and theoretically. The experiments were carried out at Cl 2 concentrations in the range of 0.01–1%. The DBD characteristics were calculated in the framework of a one-dimensional hydrodynamic model at Cl 2 concentrations in the range of 0.1–5%. It is found that the radiation intensities of the emission bands of Xe* 2 (172 nm) and XeCl* (308 nm) are comparable when the chlorine concentration in the mixture is in the range of 0.01–0.1%. In this case, in the mixture, the radiation intensity of the Xe* 2 molecule rapidly decreases with increasing Cl 2 concentration and, at a chlorine concentration of ≥0.2%, the radiation of the B → X band of XeCl* molecules with a peak at 308 nm dominates in the discharge radiation. The radiation efficiency of this band reaches its maximum value at chlorine concentrations in the range of 0.4–0.5%. The calculated efficiencies of DBD radiation exceed those obtained experimentally. This is due to limitations of the one-dimensional model, which assumes the discharge to be uniform in the transverse direction, whereas the actual excilamp discharge is highly inhomogeneous. The influence of the chlorine concentration on the properties of the DBD plasma in binary Xe-Cl 2 mixtures is studied numerically. It is shown that an increase in the Cl 2 concentration in the mixture leads to the attachment of electrons to chlorine atoms and a decrease in the electron density and discharge conductivity. As a result, the electric field and the voltage drop across the discharge gap increase, which, in turn, leads to an increase in the average electron energy and the probability of dissociation of Cl 2 molecules and ionization of Xe atoms and Cl 2 molecules. The total energy deposited in the discharge

  12. Influence of the chlorine concentration on the radiation efficiency of a XeCl exciplex lamp

    Science.gov (United States)

    Avtaeva, S. V.; Sosnin, E. A.; Saghi, B.; Panarin, V. A.; Rahmani, B.

    2013-09-01

    The influence of the chlorine concentration on the radiation efficiency of coaxial exciplex lamps (excilamps) excited by a dielectric barrier discharge (DBD) in binary Xe-Cl2 mixtures at pressures of 240-250 Torr is investigated experimentally and theoretically. The experiments were carried out at Cl2 concentrations in the range of 0.01-1%. The DBD characteristics were calculated in the framework of a one-dimensional hydrodynamic model at Cl2 concentrations in the range of 0.1-5%. It is found that the radiation intensities of the emission bands of Xe*2(172 nm) and XeCl* (308 nm) are comparable when the chlorine concentration in the mixture is in the range of 0.01-0.1%. In this case, in the mixture, the radiation intensity of the Xe*2 molecule rapidly decreases with increasing Cl2 concentration and, at a chlorine concentration of ≥0.2%, the radiation of the B → X band of XeCl* molecules with a peak at 308 nm dominates in the discharge radiation. The radiation efficiency of this band reaches its maximum value at chlorine concentrations in the range of 0.4-0.5%. The calculated efficiencies of DBD radiation exceed those obtained experimentally. This is due to limitations of the one-dimensional model, which assumes the discharge to be uniform in the transverse direction, whereas the actual excilamp discharge is highly inhomogeneous. The influence of the chlorine concentration on the properties of the DBD plasma in binary Xe-Cl2 mixtures is studied numerically. It is shown that an increase in the Cl2 concentration in the mixture leads to the attachment of electrons to chlorine atoms and a decrease in the electron density and discharge conductivity. As a result, the electric field and the voltage drop across the discharge gap increase, which, in turn, leads to an increase in the average electron energy and the probability of dissociation of Cl2 molecules and ionization of Xe atoms and Cl2 molecules. The total energy deposited in the discharge rises with increasing

  13. Hybridization Capture Using Short PCR Products Enriches Small Genomes by Capturing Flanking Sequences (CapFlank)

    DEFF Research Database (Denmark)

    Tsangaras, Kyriakos; Wales, Nathan; Sicheritz-Pontén, Thomas

    2014-01-01

    nucleotides) can result in enrichment across entire mitochondrial and bacterial genomes. Our findings suggest that some of the off-target sequences derived in capture experiments are non-randomly enriched, and that CapFlank will facilitate targeted enrichment of large contiguous sequences with minimal prior...

  14. Enterovirus 71 antagonizes the antiviral activity of host STAT3 and IL-6R with partial dependence on virus-induced miR-124.

    Science.gov (United States)

    Chang, Zhangmei; Wang, Yan; Bian, Liang; Liu, Qingqing; Long, Jian-Er

    2017-12-01

    Enterovirus 71 (EV71) has caused major outbreaks of hand, foot and mouth disease. EV71 infections increase the production of many host cytokines and pro-inflammatory factors, including interleukin (IL)-6, IL-10 and COX-2. Some of these molecules could stimulate the signal transducer and activator of transcription 3 (STAT3), which plays a key role in regulating host immune responses and several viral diseases. However, the role of STAT3 in EV71 infection remains unknown. This study found that the phosphorylation levels of STAT3 (p Y705 -STAT3) are closely related to EV71 infection. Further experiments revealed that STAT3 exerts an anti-EV71 activity. However, the antiviral activity of STAT3 is partially antagonized by EV71-induced miR-124, which directly targets STAT3 mRNA. Similarly, IL-6R, the α-subunit of the IL-6 receptor complex, exhibits anti-EV71 activity and is directly targeted by the virus-induced miR-124. These results indicate that EV71 can evade host IL-6R- and STAT3-mediated antiviral activities by EV71-induced miR-124. This suggests that controlling miR-124 and the downstream targets, IL-6R and STAT3, might benefit the antiviral treatment of EV71 infection.

  15. Integrative ChIP-seq/microarray analysis identifies a CTNNB1 target signature enriched in intestinal stem cells and colon cancer.

    Science.gov (United States)

    Watanabe, Kazuhide; Biesinger, Jacob; Salmans, Michael L; Roberts, Brian S; Arthur, William T; Cleary, Michele; Andersen, Bogi; Xie, Xiaohui; Dai, Xing

    2014-01-01

    Deregulation of canonical Wnt/CTNNB1 (beta-catenin) pathway is one of the earliest events in the pathogenesis of colon cancer. Mutations in APC or CTNNB1 are highly frequent in colon cancer and cause aberrant stabilization of CTNNB1, which activates the transcription of Wnt target genes by binding to chromatin via the TCF/LEF transcription factors. Here we report an integrative analysis of genome-wide chromatin occupancy of CTNNB1 by chromatin immunoprecipitation coupled with high-throughput sequencing (ChIP-seq) and gene expression profiling by microarray analysis upon RNAi-mediated knockdown of CTNNB1 in colon cancer cells. We observed 3629 CTNNB1 binding peaks across the genome and a significant correlation between CTNNB1 binding and knockdown-induced gene expression change. Our integrative analysis led to the discovery of a direct Wnt target signature composed of 162 genes. Gene ontology analysis of this signature revealed a significant enrichment of Wnt pathway genes, suggesting multiple feedback regulations of the pathway. We provide evidence that this gene signature partially overlaps with the Lgr5+ intestinal stem cell signature, and is significantly enriched in normal intestinal stem cells as well as in clinical colorectal cancer samples. Interestingly, while the expression of the CTNNB1 target gene set does not correlate with survival, elevated expression of negative feedback regulators within the signature predicts better prognosis. Our data provide a genome-wide view of chromatin occupancy and gene regulation of Wnt/CTNNB1 signaling in colon cancer cells.

  16. Characteristics of target polarization by laser ablation

    Czech Academy of Sciences Publication Activity Database

    Krása, Josef; Delle Side, D.; Giuffreda, E.; Nassisi, V.

    2015-01-01

    Roč. 33, č. 4 (2015), 601-605 ISSN 0263-0346 R&D Projects: GA ČR GAP205/12/0454; GA MŠk EE2.3.20.0279 Grant - others:LaserZdroj (OP VK 3)(XE) CZ.1.07/2.3.00/20.0279 Institutional support: RVO:68378271 Keywords : Target current in laser-produced plasmas * positive and negative target polarization * space structure of ion front Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.649, year: 2015

  17. MicroRNA-124 (MiR-124 Inhibits Cell Proliferation, Metastasis and Invasion in Colorectal Cancer by Downregulating Rho-Associated Protein Kinase 1(ROCK1

    Directory of Open Access Journals (Sweden)

    Liqing Zhou

    2016-05-01

    Full Text Available Background/Aims: MiR-124 inhibits neoplastic transformation, cell proliferation, and metastasis and downregulates Rho-associated protein kinase (ROCK1 in Colorectal Cancer (CRC. The aim of this study was to further investigate the roles and interactions of ROCK1 and miR-124 and the effects of knockdown of ROCK1and MiR-124 in human Colorectal Cancer (CRC. Methods: Three Colorectal cancer cell lines (HCT116, HT29 and SW620 and one Human Colonic Mucosa Epithelial cell line (NCM460 were studied. The protein expression of ROCK1 was examined by Western-blot and qRT-PCR were performed to examine the expression levels of ROCK1 mRNA and miR-124. Furthermore, We performed transfection of cancer cell line (SW620 with pre-miR-124(mimics, anti-miR-124(inhibitor, ROCK1 siRNA and the control, then observed the affects of ROCK1 protein expression by westen-blot, cell proliferation by EDU (5-ethynyl-2'deoxyuridine assay and expression levels of ROCK1mRNA by qRT-PCR . A soft agar formation assay, Migration and invasion assays were used to determine the effect of regulation of miR-124 and ROCK1, and survivin on the transformation and invasion capability of colorectal cancer cell. Results: MiR-124 expression was significantly downregulated in CRC cell lines compare to normal (P 0.05. ROCK1 mRNA was unaltered in cells transfected with miR-124 mimic and miR-124 inhibitor, compared to normal controls. There was a significant reduction in ROCK1 protein in cells transfected with miR-124 mimic and a significant increase in cells transfected with miR-124 inhibitor (P Conclusions: In conclusion, our results demonstrated that miR-124 not only promoted cancer cell hyperplasia and significantly associated with CRC metastasis and progression, but also downregulated ROCK1 protein expression. More importantly, increased ROCK1 expression or inhibited miR-124 expression may constitute effective new therapeutic strategies for the treatment of renal cancer in the future.

  18. I-124 Imaging and Dosimetry

    Directory of Open Access Journals (Sweden)

    Russ Kuker

    2017-02-01

    Full Text Available Although radioactive iodine imaging and therapy are one of the earliest applications of theranostics, there still remain a number of unresolved clinical questions as to the optimization of diagnostic techniques and dosimetry protocols. I-124 as a positron emission tomography (PET radiotracer has the potential to improve the current clinical practice in the diagnosis and treatment of differentiated thyroid cancer. The higher sensitivity and spatial resolution of PET/computed tomography (CT compared to standard gamma scintigraphy can aid in the detection of recurrent or metastatic disease and provide more accurate measurements of metabolic tumor volumes. However the complex decay schema of I-124 poses challenges to quantitative PET imaging. More prospective studies are needed to define optimal dosimetry protocols and to improve patient-specific treatment planning strategies, taking into account not only the absorbed dose to tumors but also methods to avoid toxicity to normal organs. A historical perspective of I-124 imaging and dosimetry as well as future concepts are discussed.

  19. GeoGebra and eXe Learning: applicability in the teaching of Physics and Mathematics

    Directory of Open Access Journals (Sweden)

    Eunice Maria Mussoi

    2011-04-01

    Full Text Available Today, education in the field of sciences is still characterized by excessive attention to repetitive exercises at the expense of understanding and visualizing the concepts of mathematical and physical phenomena. This article will show the potential of the software GeoGebra to build content and / or activities in Physics and Mathematics usable in isolation or engaged in other activities, such as eXe Learning. For this we constructed two activities: a mathematical content - Application of successive derivatives, and a content of physics - Application of uniform rectilinear motion. These contents were built in eXe Learning, and the graphics was built in GeoGebra and imported into the eXe by Java Applet. The content was done with the exported SCORM to Moodle, it is within this framework that the student will study the movement and display of graphic content.

  20. Test of Lorentz symmetry with a 3He/129Xe clock-comparison experiment

    International Nuclear Information System (INIS)

    Gemmel, Claudia

    2011-01-01

    The minimal Standard Model Extension (SME) of Kostelecky and coworkers, which parametrizes the general treatment of CPT- and Lorentz invariance violation, predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized 3 He and 129 Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times T * 2 of up to 4.4 h for 129 Xe and 14.1 h for 3 He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted 3 He/ 129 Xe phase difference, ΔΦ=Φ he -(γ he )/(γ xe ) Φ xe . The Lorentz-violating SME parameters for the neutron, b n X and b n Y , are determined out of a χ 2 fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The piecewise defined fit model contains a sine and a cosine term to describe the sidereal modulation, as well as 7 offset terms, 7 linear terms and 7 . 2 exponential terms decreasing with T * 2,he and T * 2,xe , which are assigned to the respective measurement. The linear term in the weighted phase difference mainly arises from deviations of the gyromagnetic ratios from their literature values due to chemical shifts, while the exponential terms reflect the phase shifts resulting from demagnetization fields in the non-ideally spherical sample cell. The result of the χ 2 fit constrains the parameter b n perpendicular to =√((b n X ) 2 +(b n Y ) 2 ) to be -32 GeV at the 95% confidence level. This

  1. Release properties of UC sub x and molten U targets

    CERN Document Server

    Roussière, B; Sauvage, J; Bajeat, O; Barre, N; Clapier, F; Cottereau, E; Donzaud, C; Ducourtieux, M; Essabaa, S; Guillemaud-Müller, D; Lau, C; Lefort, H; Liang, C F; Le Blanc, F; Müller, A C; Obert, J; Pauwels, N; Potier, J C; Pougheon, F; Proust, J; Sorlin, O; Verney, D; Wojtasiewicz, A

    2002-01-01

    The release properties of UC sub x and molten U thick targets associated with a Nier-Bernas ion source have been studied. Two experimental methods are used to extract the release time. Results are presented and discussed for Kr, Cd, I and Xe.

  2. Angular distribution of Xe 5s→epsilonp photoelectrons: Disagreement between experiment and theory

    International Nuclear Information System (INIS)

    Fahlman, A.; Carlson, T.A.; Krause, M.O.

    1983-01-01

    The angular asymmetry parameter β for the Xe 5s→epsilonp photoelectrons has been studied with use of synchrotron radiation (hν = 28--65 eV). The present results show that the relativistic random-phase approximation theory does not satisfactorily describe the Xe 5s photoionization process close to the Cooper minimum and thus require a renewed theoretical approach. The 5s partial photoionization cross section was obtained over the same photon region and the results agree with experimental values found in the literature

  3. New limit on rate of 2ν ββ decay of 136Xe

    International Nuclear Information System (INIS)

    Kuzminov, V.V.; Lobashev, V.M.; Novikov, V.M.; Ovchinnikov, B.M.; Pomansky, A.A.; Pritychenko, B.V.

    1991-01-01

    A significant background suppression was achieved in a new step of measurements in the Baksan underground laboratory 136 Xe ββ experiment, using a high-pressure gridded ionization chamber. In order to reduce outer γ-ray background, the chamber was placed inside the passive shielding consisting of 15 cm of lead and of 10 cm of copper. Half-life limit of 2.7x10 20 yrs is obtained for 2ν ββ mode of 136 Xe. (R.P.) 12 refs., 2 figs

  4. Mucosal/submucosal blood flow in the small intestine in pigs determined by local washout of 133Xe and microsphere techniques

    DEFF Research Database (Denmark)

    Mortensen, Peter; Olsen, J; Sejrsen, P

    1990-01-01

    In 11 anaesthetized pigs a laparotomy was performed and the mucosal and submucosal blood flow rate in the small intestine of the pig was determined by a local application of 133Xe and by 6.5-microns radioactive microspheres. The 133Xe washout plotted in a semilogarithmic diagram showed a multiexp......In 11 anaesthetized pigs a laparotomy was performed and the mucosal and submucosal blood flow rate in the small intestine of the pig was determined by a local application of 133Xe and by 6.5-microns radioactive microspheres. The 133Xe washout plotted in a semilogarithmic diagram showed...

  5. Low enriched uranium foil targets with different geometries for the production of Molybdenum-99 in the BMR (Brazilian Multipurpose Reactor)

    International Nuclear Information System (INIS)

    Domingos, Douglas B.; Silva, Antonio T. e; Joao, Thiago G.; Muniz, Rafael O.R.; Coelho, Talita S.

    2011-01-01

    A new research reactor is being planned in Brazil to take care of the demand of radiopharmaceuticals in the country and conduct research in various areas. This new reactor, the Brazilian Multipurpose Reactor (RMB), planned for 30 MW, is now in the conception design phase. Two low enriched ( 235 U) metallic uranium foil targets (cylinder and plate geometries) are being considered for production of Molybdenum-99 ( 99 Mo) by fission. Neutronic and thermal-hydraulics calculations were performed to compare the production of 99 Mo for these targets in the RMB and to determine the temperatures achieved in the targets. For the neutronic calculations were utilized the computer codes HAMMER-TECHNION, CITATION and SCALE and for the thermal-hydraulics calculations were utilized the computer codes MTRCR-IEA-R1 and ANSYS CFX. (author)

  6. Production of He-, Ne-, Ar-, Kr-, and Xe-isotopes by proton-induced reactions on lead

    International Nuclear Information System (INIS)

    Leya, I.; Michel, R.

    2003-01-01

    We measured integral thin target cross sections for the proton-induced production of He-, Ne-, Ar-, Kr-, and Xe-isotopes from lead from the respective reaction thresholds up to 2.6 GeV. The production of noble gas isotopes in lead by proton-induced reactions is of special importance for design studies of accelerator driven systems and energy amplifiers. In order to minimise the influences of secondary particles on the production of residual nuclides a new Mini-Stack approach was used instead of the well-known stacked-foil techniques for all experiments with proton energies above 200 MeV. With some exceptions our database for the proton-induced production of noble gas isotopes from lead is consistent and nearly complete. In contradistinction to the production of He from Al and Fe, where the cross sections obtained by thin-target irradiation experiments are up to a factor of 2 higher than the NESSI data, both datasets agree for the He production from lead. (orig.)

  7. Radiative stabilization of double-Rydberg states formed in slow Xeq+-Xe (15 ≤ q ≤ 35) collisions

    International Nuclear Information System (INIS)

    Anderson, H.; Cederquist, H.; Astner, G.; Hvelplund, P.; Pedersen, J.O.P.

    1990-01-01

    Electron capture processes, in which the projectile charge (q) is lowered by one unit, have been recorded by means of high-resolution energy-gain spectroscopy for 4q keV Xe q+ -Xe (15 ≤ q ≤ 35) collisions. The ratios, R, between the cross sections for the transfer ionisation and single-electron capture were extracted from the measured spectra. The quantity R increases slowly for charges up to q = 25 and decreases rapidly for higher q. Relying on the extended classical over-barrier model we relate R to the branching ratio for autoionisation, F, through R = k.F, and estimate the variation in k as a function of q. On the basis of the extended classical over-barrier model we ascribe the decrease in R at high q to an increase in radiative stabilization of double-Rydberg states formed in slow Xe q+ -Xe, q > 25, collisions. (orig.)

  8. Molecular dynamic simulation of interaction of low-energy Ar and Xe ions with copper clusters at graphite surface

    International Nuclear Information System (INIS)

    Kornich, G.V.; Lozovskaya, L.I.; Betts, G.; Zaporozhchenko, V.I.; Faupel, F.

    2005-01-01

    One conducted molecular and dynamic simulation of sputtering of isolated clusters consisting of 13, 27 and 195 Cu atoms from the (0001) graphite surface by 200 eV energy Ar and Xe ions. It is shown that the factors of reflection of Ar and Xe ions from copper clusters differ from one another insignificantly, though the energy of the reflected Xe ions is essentially lower than that of Ar ions. The values of the factor of cluster sputtering by Xe ions are higher in contrast to sputtering by Ar ions. One identified two mechanisms of cluster sputtering resulting in the maximum of sputtering intensity at the polar angles near the normal one, and in periodicity of maximums within the azimuth distributions of sputtering intensity with 60 deg period [ru

  9. Evaluation of {sup 124}I PET/CT and {sup 124}I PET/MRI in the management of patients with differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dercle, Laurent; Deandreis, Desiree; Terroir, Marie; Leboulleux, Sophie; Lumbroso, Jean; Schlumberger, Martin [Institut Gustave Roussy and University Paris Saclay, Department of Nuclear Medicine and Endocrine Oncology, Villejuif Cedex (France)

    2016-06-15

    The work of Binse and colleagues points out that there are probably some research perspectives for the use of {sup 124}I PET/ CT and PET/MRI in patients with DTC. It shows that there is no substantial advantage of {sup 124}I PET/MRI over {sup 124}I PET/CT for the detection of tumour lesions in the neck when using similar PET devices. It confirms the superiority of {sup 124}I PET over CT and MRI for the detection of iodine-positive lesions. It demonstrates that the use of a more sensitive PET device and a longer acquisition time leads to the detection of more lesions. {sup 124}I PET is a promising research tool for pretherapy dosimetry, the evaluation of response to {sup 131}I treatment and the staging of recurrent or residual disease. The recognized advantages of MRI are the evaluation of aerodigestive tract lesions and suprahyoid region lesions. The coregistration of MRI and {sup 124}I PET/CT might thus be more convenient than {sup 124}I PET/ MRI (shorter time of acquisition, better cost-effectiveness and more accurate attenuation correction). The benefits of these procedures in terms of patient outcome, and for the clinician and the healthcare system remain to be determined.

  10. Enhanced electrical conductivity in Xe ion irradiated CNT based transparent conducting electrode on PET substrate

    Science.gov (United States)

    Surbhi; Sharma, Vikas; Singh, Satyavir; Garg, Priyanka; Asokan, K.; Sachdev, Kanupriya

    2018-02-01

    An investigation of MWCNT-based hybrid electrode films with improved electrical conductivity after Xe ion irradiation is reported. A multilayer hybrid structure of Ag-MWCNT layer embedded in between two ZnO layers was fabricated and evaluated, pre and post 100 keV Xe ion irradiation, for their performance as Transparent Conducting Electrode in terms of their optical and electrical properties. X-ray diffraction pattern exhibits highly c-axis oriented ZnO films with a small variation in lattice parameters with an increase in ion fluence. There is no significant change in the surface roughness of these films. Raman spectra were used to confirm the presence of CNT. The pristine multilayer films exhibit an average transmittance of ˜70% in the entire visible region and the transmittance increases with Xe ion fluence. A significant enhancement in electrical conductivity post-Xe ion irradiation viz from 1.14 × 10-7 Ω-1 cm-1 (pristine) to 7.04 × 103 Ω-1 cm-1 is seen which is due to the high connectivity in the top layer with Ag-CNT hybrid layer facilitating the smooth transfer of electrons.

  11. Performance characteristics of an excimer laser (XeCl) with single ...

    Indian Academy of Sciences (India)

    2017-01-10

    Jan 10, 2017 ... Performance characteristics of an excimer laser (XeCl) with single-stage magnetic ... the stress can increase the lifetime of the switches and ..... work. References. [1] Ying-Tung Chen, Kris Naessens, Roel Bates, Yunn-Shiuan.

  12. Determination of electron impact ionization and excitation coefficients in He-Xe gas mixtures. He-Xe kongo gas ni okeru denshi shototsu denri keisu oyobi reiki keisu no sokutei to kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, K.; Tachibana, K. (Kyoto Inst. of Technology, Kyoto (Japan))

    1991-03-20

    The rare gas discharge gives a stable discharge and light emission characteristics at low temperature in comparison with the discharge of the vapor of such a metal as Hg. The present barrier for the commercialization of the color PDP lies in the lower level of its emission intensity and efficiency in comparison with that of CRT. In this report, an electron impact ionization coefficient in a gas mixture and an electron impact excitation coefficient for a XeIs {sub 4} level were analyzed using a Boltzmann equation by means of a steady state Townsend method using a drift tube. By comparing both, the elementary process in the gas mixture is investiagted to discuss the respective contributions for the effective ionization coefficient and the excitation coefficient. As a result, it was found that the ionization process in the He-Xe gas mixture could be described by the processes of direct ionization of Xe and He, and an indirect ionization (Penning effect) by an active helium. 37 refs., 12 figs.

  13. Search for neutrinoless double beta decay in {sup 136}Xe with EXO-200

    Energy Technology Data Exchange (ETDEWEB)

    Feldmeier, Wolfhart

    2015-02-19

    Several properties of neutrinos, such as their absolute mass, their possible Majorana nature or the mechanisms that lead to small neutrino masses, are still unknown. The EXO-200 experiment is trying to answer some of these questions by searching for the hypothetical neutrinoless double beta decay of the isotope {sup 136}Xe. This thesis describes an analysis of two years of detector data, which yields a lower limit on the half-life of neutrinoless double beta decay of {sup 136}Xe of 1.1 x 10{sup 25} years.

  14. Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

    Energy Technology Data Exchange (ETDEWEB)

    Ackerman, N.; /SLAC; Aharmim, B.; /Laurentian U.; Auger, M.; /Bern U.; Auty, D.J.; /Alabama U.; Barbeau, P.S.; Barry, K.; Bartoszek, L.; /Stanford U., Phys. Dept.; Beauchamp, E.; /Laurentian U.; Belov, V.; /Moscow, ITEP; Benitez-Medina, C.; /Colorado State U.; Breidenbach, M.; /SLAC; Burenkov, A.; /Moscow, ITEP; Cleveland, B.; /Laurentian U.; Conley, R.; Conti, E.; /SLAC; Cook, J.; /Massachusetts U., Amherst; Cook, S.; /Colorado State U.; Coppens, A.; /Carleton U.; Counts, I.; /Stanford U., Phys. Dept.; Craddock, W.; /SLAC; Daniels, T.; /Massachusetts U., Amherst /Moscow, ITEP /Maryland U. /Stanford U., Phys. Dept. /Alabama U. /Maryland U. /Moscow, ITEP /Stanford U., Phys. Dept. /Laurentian U. /Carleton U. /Colorado State U. /Laurentian U. /Munich, Tech. U. /Bern U. /SLAC /Bern U. /Carleton U. /Stanford U., Phys. Dept. /Carleton U. /Maryland U. /Colorado State U. /SLAC /Carleton U. /SLAC /Alabama U. /SLAC /Moscow, ITEP /Indiana U. /Stanford U., Phys. Dept. /Moscow, ITEP /Stanford U., Phys. Dept. /Massachusetts U., Amherst /Seoul U. /Carleton U. /Stanford U., Phys. Dept.; /more authors..

    2012-09-14

    We report the observation of two-neutrino double-beta decay in {sup 136}Xe with T{sub 1/2} = 2.11 {+-} 0.04(stat) {+-} 0.21(syst) x 10{sup 21} yr. This second-order process, predicted by the standard model, has been observed for several nuclei but not for {sup 136}Xe. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrinoless double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

  15. A novel Cs-(129)Xe atomic spin gyroscope with closed-loop Faraday modulation.

    Science.gov (United States)

    Fang, Jiancheng; Wan, Shuangai; Qin, Jie; Zhang, Chen; Quan, Wei; Yuan, Heng; Dong, Haifeng

    2013-08-01

    We report a novel Cs-(129)Xe atomic spin gyroscope (ASG) with closed-loop Faraday modulation method. This ASG requires approximately 30 min to start-up and 110 °C to operate. A closed-loop Faraday modulation method for measurement of the optical rotation was used in this ASG. This method uses an additional Faraday modulator to suppress the laser intensity fluctuation and Faraday modulator thermal induced fluctuation. We theoretically and experimentally validate this method in the Cs-(129)Xe ASG and achieved a bias stability of approximately 3.25 °∕h.

  16. Status report on developing I-124, Pd-103, Tc-94m, Br-76 and Cu-64 radioisotopes at KIRAMS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. H.; Kim, S. K.; Han, S. J.; Oh, T. H.; Kim, K. K.; Park, H.; Lee, J. S.; Jun, K. S. [KIRAMS, Seoul (Korea, Republic of)

    2005-07-01

    The decay characteristics of their radioisotopes such as I-124, Pd-103, Tc-94m, Br-76 and Cu-64 radionuclides produced by cyclotron have considered useful agents for diagnostic imaging or therapy. In order to increase the availability of the radionuclides, the investigation for the high capacity target design and simple procedures yielding high activities is being carried. Therefore, KIRAMS will lead researchers in nuclear medicine to access the feasibility of reliable production for enough quantities of several research radioisotopes using (p,xn) reactions. The quality and yield of products are evaluated theoretically from the excitation functions as a function of proton energies, target thickness, bombarding time, and growth time. Radionuclidic impurities are determined by gamma-spectrometer with high purity Germanium (HPGe) detector and the yields are read by ion chamber. Multi-millicuries of radioisotope I-124 (23% positron emission, half-life 4.2 days) is produced by 125-TeO2(p,2n)124-I reaction at the incident proton energy of 22 MeV. The production of carrier-free Pd-103 by the 103Rh(p,n)103Pd reaction with the 18 MeV proton beam. The electroplating method of Rh to Cu plate and recovery of rhodium from irradiated target fragments will be discussed. The thermal stability of Rh films on Cu plate will be tested for the mass production by increasing beam current up to 220uA with high-current cyclotron. For Cu-64, Tc-94m and Br-76 radionuclides, the target preparation and separating techniques are under developing. Our research project emphasis is in the development of routine methods for the production of Pd-103 radionuclide for brachytherapy seed and PET radionuclides, which include I-124, Tc-94m, Br-76 and Cu-64. In addition to the production of these radionuclides, we are developing novel radiopharmaceuticals utilizing these isotopes for both imaging and therapy.

  17. Experimental preparation of Kr/Xe hydrate at pressures up to 160 bar

    International Nuclear Information System (INIS)

    Simonis, R.

    1985-06-01

    A compound called gas (mixture) hydrate is formed under pressurized atmosphere by reaction of krypton, xenon and a mixture of both with water. The study under review reports on preparing such hydrates experimentally under pressures up to 160 bar. The dissociation function of the hydrates is determined by low and medium-pressure experiments. Observing the formation process it was found that a hydrate layer is formed at the interface of gas and water, its separating effect almost inhibiting continuance of hydrate reactions. Strong stirring will avoid or destroy the separating layer. It is shown that at pressures above 50 bar the dissociation function psub(D) (T) gets non-linear with logarithmic pressure plotting above the absolute, reciprocal temperature. The medium-temperature experiments show that the density of the gas consisting of Xe or Kr and Xe, respectively, reaches higher values than that of the water. In this case, the system collapses and the gas is found at the bottom of the pressure flask, and the water in the top region. The gas samples taken during the mixed hydrate preparation show that Kr is accumulated in the gaseous phase, and Xe in the hydrate phase. (orig./RB) [de

  18. Cluster-surface collisions: Characteristics of Xe55- and C20 - Si[111] surface bombardment

    International Nuclear Information System (INIS)

    Cheng, H.

    1999-01-01

    Molecular dynamics (MD) simulations are performed to study the cluster-surface collision processes. Two types of clusters, Xe 55 and C 20 are used as case studies of materials with very different properties. In studies of Xe 55 - Si[111] surface bombardment, two initial velocities, 5.0 and 10.0 km/s (normal to the surface) are chosen to investigate the dynamical consequences of the initial energy or velocity in the cluster-surface impact. A transition in the speed of kinetic energy propagation, from subsonic velocities to supersonic velocities, is observed. Energy transfer, from cluster translational motion to the substrate, occurs at an extremely fast rate that increases as the incident velocity increases. Local melting and amorphous layer formation in the surfaces are found via energetic analysis of individual silicon atoms. For C 20 , the initial velocity ranges from 10 to 100 km/s. The clusters are damaged immediately upon impact. Similar to Xe 55 , increase in the potential energy is larger than the increase in internal kinetic energy. However, the patterns of energy distribution are different for the two types of clusters. The energy transfer from the carbon clusters to Si(111) surface is found to be slower than that found in the Xe clusters. Fragmentation of the carbon cluster occurs when the initial velocity is greater than 30 km/s. At 10 km/s, the clusters show recrystallization at later times. The average penetration depth displays a nonlinear dependence on the initial velocity. Disturbance in the surface caused by C 20 is discussed and compared to the damage caused by Xe 55 . Energetics, structures, and dynamics of these systems are fully analyzed and characterized. copyright 1999 American Institute of Physics

  19. 32 CFR 536.124 - Settlement authority for maritime claims.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Settlement authority for maritime claims. 536.124 Section 536.124 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY CLAIMS AND ACCOUNTS CLAIMS AGAINST THE UNITED STATES Maritime Claims § 536.124 Settlement authority for maritime...

  20. Radiation stability of nanocrystalline ZrN coatings irradiated with high energy Xe and Bi ions

    International Nuclear Information System (INIS)

    Skuratov, V.A.; Sokhatsky, A.S.; Uglov, V.V.; Zlotski, S.V.; Van Vuuren, A.J.; Neethling, Jan; O'Connell, J.

    2011-01-01

    Swift Xe and Bi ion irradiation effects in nanocrystalline ZrN coatings as a function of ion fluence are reported. Zirconium nitride films of different thickness (0.1, 3, 10 and 20 micrometers) synthesized by vacuum arc-vapour deposition in nanocrystalline state (average size of crystallites is ∼4 nm) were irradiated with 167 MeV Xe and 695 MeV Bi ions to fluences in the range 3x10 12 ÷2.6x10 15 cm -2 (Xe) and 10 12 x10 13 cm -2 (Bi) and studied using XRD and TEM techniques. No evidence of amorphization due to high level ionizing energy losses has been found. The measurements of lattice parameter have revealed nonmonotonic dependence of the stress level in irradiated samples on ion fluence. (authors)

  1. Two-phonon giant resonances in 136Xe, 208Pb, and 238U

    International Nuclear Information System (INIS)

    Boretzky, K.; Gruenschloss, A.; Ilievski, S.; Adrich, P.; Aumann, T.; Bertulani, C.A.; Cub, J.; Dostal, W.; Eberlein, B.; Elze, T.W.; Emling, H.; Fallot, M.; Holeczek, J.; Holzmann, R.; Kozhuharov, C.; Kratz, J.V.; Kulessa, R.; Leifels, Y.; Leistenschneider, A.; Lubkiewicz, E.; Mordechai, S.; Ohtsuki, T.; Reiter, P.; Simon, H.; Stelzer, K.; Stroth, J.; Suemmerer, K.; Surowiec, A.; Wajda, E.; Walus, W.

    2003-07-01

    The excitation of the double-phonon giant dipole resonance was observed in heavy projectile nuclei impinging on targets of high nuclear charge with energies of 500-700 MeV/nucleon. New experimental data are presented for 136 Xe and 238 U together with further analysis of earlier data on 208 Pb. Differential cross sections dσ/dE * and dσ/dθ for electromagnetic excitations were deduced. Depending on the isotope, cross sections appear to be enhanced in comparison to those expected from a purely harmonic nuclear dipole response. The cumulative effect of excitations of two-phonon states composed of one dipole and one quadrupole phonon, of predicted anharmoniticies in the double-phonon dipole response, and of damping of the dipole resonance during the collision may account for the discrepancy. In addition, decay properties of two-phonon resonances were studied and compared to that of a statistical decay. (orig.)

  2. Threshold collision-induced dissociation of diatomic molecules: a case study of the energetics and dynamics of O2- collisions with Ar and Xe.

    Science.gov (United States)

    Ahu Akin, F; Ree, Jongbaik; Ervin, Kent M; Kyu Shin, Hyung

    2005-08-08

    The energetics and dynamics of collision-induced dissociation of O2- with Ar and Xe targets are studied experimentally using guided ion-beam tandem mass spectrometry. The cross sections and the collision dynamics are modeled theoretically by classical trajectory calculations. Experimental apparent threshold energies are 2.1 and 1.1 eV in excess of the thermochemical O2- bond dissociation energy for argon and xenon, respectively. Classical trajectory calculations confirm the observed threshold behavior and the dependence of cross sections on the relative kinetic energy. Representative trajectories reveal that the bond dissociation takes place on a short time scale of about 50 fs in strong direct collisions. Collision-induced dissociation is found to be remarkably restricted to the perpendicular approach of ArXe to the molecular axis of O2-, while collinear collisions do not result in dissociation. The higher collisional energy-transfer efficiency of xenon compared with argon is attributed to both mass and polarizability effects.

  3. Threshold collision-induced dissociation of diatomic molecules: A case study of the energetics and dynamics of O2- collisions with Ar and Xe

    International Nuclear Information System (INIS)

    Ahu Akin, F.; Ree, Jongbaik; Ervin, Kent M.; Hyung, Kyu Shin

    2005-01-01

    The energetics and dynamics of collision-induced dissociation of O 2 - with Ar and Xe targets are studied experimentally using guided ion-beam tandem mass spectrometry. The cross sections and the collision dynamics are modeled theoretically by classical trajectory calculations. Experimental apparent threshold energies are 2.1 and 1.1 eV in excess of the thermochemical O 2 - bond dissociation energy for argon and xenon, respectively. Classical trajectory calculations confirm the observed threshold behavior and the dependence of cross sections on the relative kinetic energy. Representative trajectories reveal that the bond dissociation takes place on a short time scale of about 50 fs in strong direct collisions. Collision-induced dissociation is found to be remarkably restricted to the perpendicular approach of Ar/Xe to the molecular axis of O 2 - , while collinear collisions do not result in dissociation. The higher collisional energy-transfer efficiency of xenon compared with argon is attributed to both mass and polarizability effects

  4. Effects of Xe Gas Content and Total Gas Pressure on the Discharge Characteristics of Colour Plasma Display Panels

    International Nuclear Information System (INIS)

    Hu Wenbo; Han Mengju; Liang Zhihu

    2006-01-01

    The effects of the Xe gas content and total gas pressure on the discharge characteristics of colour plasma display panels including the sustaining voltage margin, white-field chromaticity, discharge time lag (DTL), discharge current peak, and full-width-at-half-maximum (FWHM) of the discharge current pulse, are experimentally studied. The results indicate that as the Xe gas content in the He-Ne-Xe gas mixture or total pressure increases, the sustaining voltage margin increases, the white-field chromaticity improves, and the discharge current peak has a maximum value, while DTL and FWHM have a minimum value. The mean electron energy in the gas mixture discharge is also calculated through a numerical solution of Boltzmann equation. The experimental results are explained from a view of the mean electron energy variations with the Xe gas content and total gas pressure

  5. Generator Coordinate Method Analysis of Xe and Ba Isotopes

    Science.gov (United States)

    Higashiyama, Koji; Yoshinaga, Naotaka; Teruya, Eri

    Nuclear structure of Xe and Ba isotopes is studied in terms of the quantum-number projected generator coordinate method (GCM). The GCM reproduces well the energy levels of high-spin states as well as low-lying states. The structure of the low-lying states is analyzed through the GCM wave functions.

  6. Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications

    Science.gov (United States)

    Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M. L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-12-01

    As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs.

  7. Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications☆

    Science.gov (United States)

    Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M.L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-01-01

    As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs. PMID:24135800

  8. Photoionisation study of Xe.CF{sub 4} and Kr.CF{sub 4} van-der-Waals molecules

    Energy Technology Data Exchange (ETDEWEB)

    Alekseev, V. A., E-mail: alekseev@va3474.spb.edu; Kevorkyants, R. [St. Petersburg State University, 7/9 Universitetskaya Nab., St. Petersburg 199034 (Russian Federation); Garcia, G. A.; Nahon, L. [Synchrotron Soleil, Orme des Merisiers, St. Aubin BP 48, 91192 Gif sur Yvette Cedex (France)

    2016-05-14

    We report on photoionization studies of Xe.CF{sub 4} and Kr.CF{sub 4} van-der-Waals complexes produced in a supersonic expansion and detected using synchrotron radiation and photoelectron-photoion coincidence techniques. The ionization potential of CF{sub 4} is larger than those of the Xe and Kr atoms and the ground state of the Rg.CF{sub 4}{sup +} ion correlates with Rg{sup +} ({sup 2}P{sub 3/2}) + CF{sub 4}. The onset of the Rg.CF{sub 4}{sup +} signals was found to be only ∼0.2 eV below the Rg ionization potential. In agreement with experiment, complementary ab initio calculations show that vertical transitions originating from the potential minimum of the ground state of Rg.CF{sub 4} terminate at a part of the potential energy surfaces of Rg.CF{sub 4}{sup +}, which are approximately 0.05 eV below the Rg{sup +} ({sup 2}P{sub 3/2}) + CF{sub 4} dissociation limit. In contrast to the neutral complexes, which are most stable in the face geometry, for the Rg.CF{sub 4}{sup +} ions, the calculations show that the minimum of the potential energy surface is in the vertex geometry. Experiments which have been performed only with Xe.CF{sub 4} revealed no Xe.CF{sub 4}{sup +} signal above the first ionization threshold of Xe, suggesting that the Rg.CF{sub 4}{sup +} ions are not stable above the first dissociation limit.

  9. 13 CFR 124.520 - Mentor/protege program.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Mentor/protege program. 124.520... § 124.520 Mentor/protege program. (a) General. The mentor/protege program is designed to encourage approved mentors to provide various forms of assistance to eligible Participants. This assistance may...

  10. Low enriched uranium foil targets with different geometries for the production of Molybdenum-99 in the BMR (Brazilian Multipurpose Reactor)

    Energy Technology Data Exchange (ETDEWEB)

    Domingos, Douglas B.; Silva, Antonio T. e; Joao, Thiago G.; Muniz, Rafael O.R.; Coelho, Talita S., E-mail: teixeira@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    A new research reactor is being planned in Brazil to take care of the demand of radiopharmaceuticals in the country and conduct research in various areas. This new reactor, the Brazilian Multipurpose Reactor (RMB), planned for 30 MW, is now in the conception design phase. Two low enriched (<20% {sup 235}U) metallic uranium foil targets (cylinder and plate geometries) are being considered for production of Molybdenum-99 ({sup 99}Mo) by fission. Neutronic and thermal-hydraulics calculations were performed to compare the production of {sup 99}Mo for these targets in the RMB and to determine the temperatures achieved in the targets. For the neutronic calculations were utilized the computer codes HAMMER-TECHNION, CITATION and SCALE and for the thermal-hydraulics calculations were utilized the computer codes MTRCR-IEA-R1 and ANSYS CFX. (author)

  11. Integrative ChIP-seq/microarray analysis identifies a CTNNB1 target signature enriched in intestinal stem cells and colon cancer.

    Directory of Open Access Journals (Sweden)

    Kazuhide Watanabe

    Full Text Available Deregulation of canonical Wnt/CTNNB1 (beta-catenin pathway is one of the earliest events in the pathogenesis of colon cancer. Mutations in APC or CTNNB1 are highly frequent in colon cancer and cause aberrant stabilization of CTNNB1, which activates the transcription of Wnt target genes by binding to chromatin via the TCF/LEF transcription factors. Here we report an integrative analysis of genome-wide chromatin occupancy of CTNNB1 by chromatin immunoprecipitation coupled with high-throughput sequencing (ChIP-seq and gene expression profiling by microarray analysis upon RNAi-mediated knockdown of CTNNB1 in colon cancer cells.We observed 3629 CTNNB1 binding peaks across the genome and a significant correlation between CTNNB1 binding and knockdown-induced gene expression change. Our integrative analysis led to the discovery of a direct Wnt target signature composed of 162 genes. Gene ontology analysis of this signature revealed a significant enrichment of Wnt pathway genes, suggesting multiple feedback regulations of the pathway. We provide evidence that this gene signature partially overlaps with the Lgr5+ intestinal stem cell signature, and is significantly enriched in normal intestinal stem cells as well as in clinical colorectal cancer samples. Interestingly, while the expression of the CTNNB1 target gene set does not correlate with survival, elevated expression of negative feedback regulators within the signature predicts better prognosis.Our data provide a genome-wide view of chromatin occupancy and gene regulation of Wnt/CTNNB1 signaling in colon cancer cells.

  12. Linearity discontinuities in Xe-filled X-ray microstrip detectors

    DEFF Research Database (Denmark)

    Zavattini, G.; Feroci, M.; Budtz-Jørgensen, Carl

    1997-01-01

    A prototype Xe + 10% CH4 microstrip detector was used to study the K-edge discontinuity in the pulse-height distribution as a function of the energy of incident X-rays. The electronics used was such that a pulse-shape rejection could be made of K-fluorescence reabsorption in the detector. The mea...

  13. Determination of adipose tissue blood flow with local 133Xe clearance. Evaluation of a new labelling technique

    DEFF Research Database (Denmark)

    Simonsen, Lene; Enevoldsen, Lotte Hahn; Bülow, Jens

    2003-01-01

    Adipose tissue blood flow was measured in six healthy, non-obese subjects with the xenon wash-out technique after labelling of the tissue by either injection of 133Xe dissolved in isotonic sodium chloride (water depot) or injection of 133Xe in gas form (gas depot). The wash-out rates were...

  14. Exploring multifragmentation with a 4π detector: Xe-induced reactions at Ebeam = 60 MeV/nucleon

    International Nuclear Information System (INIS)

    Skulski, W.; Tso, K.; Colonna, N.

    1994-01-01

    The reactions 129 Xe + 27 Al, nat Cu, 89 Y, 165 Ho and 197 Au at 60 MeV/nucleon were investigated with the combination of a high-resolution forward array of Si-Si-plastic telescopes and a high-efficiency phoswich ball. The projectile-like primary source was reconstructed. Its parallel velocity component is strongly correlated with the observed multiplicity and hence with dissipation. At high multiplicity, large fragments still show a projectile-like and target-like components in their parallel velocity distributions. A further sub-division of highly dissipative events into binary-like and non binary-like subclasses has been performed by applying an additional experimental selection of the orientation of the event in momentum space

  15. Evaluation of cutaneous blood flow responses by 133Xe washout and a laser-Doppler flowmeter

    International Nuclear Information System (INIS)

    Engelhart, M.; Kristensen, J.K.

    1983-01-01

    A new method for noninvasive measurement of cutaneous blood flow is laser-Doppler flowmetry. The technique is based on the fact that laser light is back-scattered from the moving red blood cells, with Doppler-shifted frequencies; these impulses lead to photodetectors and are converted to flow signals. In this work we used a new system with a low noise level. Comparison was made between this technique and the atraumatic epicutaneous 133 Xe technique for measurement of cutaneous blood flow during reactive hyperemia and orthostatic pressure changes. The laser-Doppler flowmeter seems to measure blood flow in capillaries as well as in arteriovenous anastomoses, while the 133 Xe method probably measures only capillary flow. A calibration of the laser-Doppler method against the 133 Xe method would appear to be impossible in skin areas where arteriovenous anastomoses are present. The changes in blood flow during reactive hyperemia, orthostatic pressure changes, and venous stasis were found to be parallel as measured by the two methods in skin areas without shunt vessels. The laser-Doppler flowmeter would appear to be a useful supplement to the 133Xe washout method in cutaneous vascular physiology, but it is important to keep in mind that different parameters may be measured

  16. 29 CFR 780.124 - Raising of fur-bearing animals.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Raising of fur-bearing animals. 780.124 Section 780.124... General Scope of Agriculture Raising of Livestock, Bees, Fur-Bearing Animals, Or Poultry § 780.124 Raising of fur-bearing animals. (a) The term “fur-bearing animals” has reference to animals which bear fur of...

  17. Experimental conditions improving in-solution target enrichment for ancient DNA

    DEFF Research Database (Denmark)

    Cruz-Dávalos, Diana I.; Llamas, Bastien; Gaunitz, Charleen

    2017-01-01

    High-throughput sequencing has dramatically fostered ancient DNA research in recent years. Shotgun sequencing, however, does not necessarily appear as the best-suited approach due to the extensive contamination of samples with exogenous environmental microbial DNA. DNA capture-enrichment methods ...

  18. Radioactive decay and nuclear structure studies: Progress report, October 1, 1986 through September 30, 1987

    International Nuclear Information System (INIS)

    Walters, W.B.

    1987-01-01

    New data are presented for the level structures of 143 Ba, 147 Ce, 147 Pr, 143 Cs, 132 Sb, 130 Sb, 129 Sb, 129 Te, and 132 Te. New conversion electron and gamma-ray coincidence measurements are reported for the even-even 118 Xe, 120 Xe, 122 Xe, 124 Xe nuclides which include the identification of a number of new E0 transitions. New values for the magnetic moments in 77 Br, 75 Br, and 74 Br are presented. The results for each of these nuclides are discussed

  19. Single-pulse characteristics of the Xe(L) amplifier on the Xe35+ (3d→2p) transition array at λ ≅ 2.86 A

    International Nuclear Information System (INIS)

    Borisov, Alex B; Song Xiangyang; Zhang Ping; McCorkindale, John C; Khan, Shahab F; De Jonghe, Richard; Poopalasingam, Sankar; Zhao, Ji; Boyer, Keith; Rhodes, Charles K

    2006-01-01

    The triple comparison of (1) single-pulse spectral data, recorded with a CCD-equipped von Hamos spectrometer both axially and transversely; (2) axially measured time-integrated spectra registered on a film and (3) single-pulse x-ray images of the morphology of the self-trapped plasma channel, recorded simultaneously with the single-pulse spectra, establishes several leading characteristics of the saturated amplification observed on the Xe 35+ transition array at λ ≅ 2.86 A. The chief findings are (α) absolute positive correlation of amplification with the formation of a plasma channel, (β) a perfect spectral match of the amplified transitions in the comparison of axially recorded single-pulse and time-integrated film data and (γ) exact spectral correspondence of both the axially registered single-pulse and time-integrated film data with single-pulse transversely measured spectra exhibiting deep spectral hole burning at the position of the Xe 35+ array. (letter to the editor)

  20. 9 CFR 124.40 - Request for hearing.

    Science.gov (United States)

    2010-01-01

    ... Diligence Hearing § 124.40 Request for hearing. (a) Any interested person may request, within 60 days beginning on the date of publication of a due diligence determination by APHIS in accordance with § 124.32, that APHIS conduct an informal hearing on the due diligence determination. (b) The request for a...

  1. Synthesis, Characterization and Antifungal Evaluation of 5-Substituted-4-Amino-1,2,4-Triazole-3-Thioesters

    Directory of Open Access Journals (Sweden)

    Aurangzeb Hasan

    2011-01-01

    Full Text Available A series of 5-substituted-4-amino-1,2,4-triazole-3-thioesters was synthesized by converting variously substituted organic acids successively into the corresponding esters, hydrazides, 5-substituted-1,3,4-oxadiazole-2-thiols, 5-substituted-1,2,4-triazole-2-thiols and 5-substituted-1,3,4-oxadiazole-2-thioesters. Finally the target compounds were obtained by refluxing 5-substituted-1,3,4-oxadiazole-2-thioesters in the presence of hydrazine hydrate and absolute alcohol. The structures of the synthesized compounds were established by physicochemical and spectroscopic methods. The synthesized compounds were evaluated for their in vitro antifungal activity. Some of the evaluated compounds possessed significant antifungal activity as compared to a terbinafine standard.

  2. Inoculation stress hypothesis of environmental enrichment.

    Science.gov (United States)

    Crofton, Elizabeth J; Zhang, Yafang; Green, Thomas A

    2015-02-01

    One hallmark of psychiatric conditions is the vast continuum of individual differences in susceptibility vs. resilience resulting from the interaction of genetic and environmental factors. The environmental enrichment paradigm is an animal model that is useful for studying a range of psychiatric conditions, including protective phenotypes in addiction and depression models. The major question is how environmental enrichment, a non-drug and non-surgical manipulation, can produce such robust individual differences in such a wide range of behaviors. This paper draws from a variety of published sources to outline a coherent hypothesis of inoculation stress as a factor producing the protective enrichment phenotypes. The basic tenet suggests that chronic mild stress from living in a complex environment and interacting non-aggressively with conspecifics can inoculate enriched rats against subsequent stressors and/or drugs of abuse. This paper reviews the enrichment phenotypes, mulls the fundamental nature of environmental enrichment vs. isolation, discusses the most appropriate control for environmental enrichment, and challenges the idea that cortisol/corticosterone equals stress. The intent of the inoculation stress hypothesis of environmental enrichment is to provide a scaffold with which to build testable hypotheses for the elucidation of the molecular mechanisms underlying these protective phenotypes and thus provide new therapeutic targets to treat psychiatric/neurological conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Liquid-Xe detector for contraband detection

    Energy Technology Data Exchange (ETDEWEB)

    Vartsky, D., E-mail: david.vartsky@weizmann.ac.il [Weizmann Institute of Science, Rehovot 76100 (Israel); Israelashvili, I. [Weizmann Institute of Science, Rehovot 76100 (Israel); Nuclear Research Center of Negev (NRCN), Beer-Sheva 9001 (Israel); Cortesi, M. [National Superconducting Cyclotron Laboratory, East Lansing 48823, MI (United States); Arazi, L.; Coimbra, A.E.; Moleri, L.; Erdal, E.; Bar, D.; Rappaport, M.; Shchemelinin, S. [Weizmann Institute of Science, Rehovot 76100 (Israel); Caspi, E.N. [Nuclear Research Center of Negev (NRCN), Beer-Sheva 9001 (Israel); Aviv, O. [Soreq NRC, Yavne 81800 (Israel); Breskin, A. [Weizmann Institute of Science, Rehovot 76100 (Israel)

    2016-07-11

    We describe progress made with a liquid-Xe (LXe) detector coupled to a gaseous photomultiplier (GPM), for combined imaging and spectroscopy of fast neutrons and gamma-rays in the MeV range. The purpose of this detector is to enable the detection of hidden explosives and fissile materials in cargo and containers. The expected position resolution is about 2 m and 3.5 mm for fast neutrons and gamma-rays, respectively. Experimental results obtained using an {sup 241}Am source yielded energy and time resolutions of 11% and 1.2 ns RMS, respectively. Initial results obtained with the position-sensitive GPM are presented.

  4. Temperature enhancement of Xe(L) x-ray amplifier (λ ∼ 2.9 A) emission

    International Nuclear Information System (INIS)

    Borisov, Alex B; Zhang Ping; Racz, Ervin; McCorkindale, John C; Khan, Shahab F; Poopalasingam, Sankar; Zhao Ji; Rhodes, Charles K

    2007-01-01

    Cooling of the xenon nozzle flow to T = 230 K produces three leading effects. They are (1) a ∼2.5-fold enhancement of the Xe(L) hollow atom emission on the single-vacancy 3d → 2p charge state arrays (2) the production of amplifying self-trapped plasma channels with significantly enhanced lengths and (3) very sharply augmented emission on (2s-bar2p-bar) Xe(L) double-vacancy transitions in the λ ≅ 2.80 A region. (fast track communication)

  5. Temperature enhancement of Xe(L) x-ray amplifier ({lambda} {approx} 2.9 A) emission

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, Alex B [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Zhang Ping [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Racz, Ervin [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); McCorkindale, John C [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Khan, Shahab F [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Poopalasingam, Sankar [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Zhao Ji [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Rhodes, Charles K [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States)

    2007-11-28

    Cooling of the xenon nozzle flow to T = 230 K produces three leading effects. They are (1) a {approx}2.5-fold enhancement of the Xe(L) hollow atom emission on the single-vacancy 3d {yields} 2p charge state arrays (2) the production of amplifying self-trapped plasma channels with significantly enhanced lengths and (3) very sharply augmented emission on (2s-bar2p-bar) Xe(L) double-vacancy transitions in the {lambda} {approx_equal} 2.80 A region. (fast track communication)

  6. Structural Search for High Pressure CS2 and Xe-Cl Compounds

    Science.gov (United States)

    Zarifi, Niloofar; Tse, John S.

    2018-04-01

    The recent successful implementation of several methodologies for the prediction of crystal structures based on the first-principles electronic structure have ushered in a new area of computational chemistry. In this study, the two most popular methods, namely genetic evolution and particle swarm optimization, were applied to the investigation of stable crystalline polymorphs of solid carbon disulfide and xenon halides at high pressure. It was found that both methods have their own merits. However, there are subtleties that need to be considered for the proper execution of the methods. We found a two-dimensional (2D) layered structure that may be responsible for the superconductivity in CS2. Except for XeCl2, no thermodynamically stable crystalline Xe halides were found under 60 GPa in the halide-rich region of the phase diagram.

  7. Cryptophane-Folate Biosensor for 129Xe NMR

    Science.gov (United States)

    2014-12-01

    normal adult tissue, but as the name implies, this low affinity folate carrier is specific for the physiological form of reduced folic acid, 5- methyl ...yield. Finally, 3 was treated with 1.5 equiv of 6 and N- methyl -1,5,9-triazabicyclo[4.4.0]-decene (MTBD) in dry DMSO to give the folate recognition moiety...Cryptophane- Folate Biosensor for 129Xe NMR Najat S. Khan, Brittany A. Riggle, Garry K. Seward, Yubin Bai, and Ivan J. Dmochowski* Department of

  8. Multifragmentation in intermediate energy 129Xe-induced heavy-ion reactions

    Energy Technology Data Exchange (ETDEWEB)

    Tso, Kin [Univ. of California, Berkeley, CA (United States)

    1996-05-01

    The 129Xe-induced reactions on natCu, 89Y, 165Ho, and 197Au at bombarding energies of E/A = 40 & 60 MeV have been studied theoretically and experimentally in order to establish the underlying mechanism of multifragmentation at intermediate energy heavy-Ion collisions. Nuclear disks formed in central heavy-ion collisions, as simulated by means of Boltzmann-like kinetic equations, break up into several fragments due to a new kind of Rayleigh-like surface instability. A sheet of liquid, stable in the limit of non-interacting surfaces, is shown to become unstable due to surface-surface interactions. The onset of this instability is determined analytically. A thin bubble behaves like a sheet and is susceptible to the surface instability through the crispation mode. The Coulomb effects associated with the depletion of charges in the central cavity of nuclear bubbles are investigated. The onset of Coulomb instability is demonstrated for perturbations of the radial mode. Experimental intermediate-mass-fragment multiplicity distributions for the 129Xe-induced reactions are shown to be binomial at each transverse energy. From these distributions, independent of the specific target, an elementary binary decay probability p can be extracted that has a thermal dependence. Thus it is inferred that multifragmentation is reducible to a combination of nearly independent emission processes. If sequential decay is assumed, the increase of p with transverse energy implies a contraction of the emission time scale. The sensitivity of p to the lower Z threshold in the definition of intermediate-mass-fragments points to a physical Poisson simulations of the particle multiplicities show that the weak auto-correlation between the fragment multiplicity and the transverse energy does not distort a Poisson distribution into a binomial distribution. The effect of device efficiency on the experimental results has also been studied.

  9. Structure and stability of solid Xe(H2)n

    International Nuclear Information System (INIS)

    Somayazulu, Maddury; Hemley, Russell J.; Dera, Przemyslaw; Smith, Jesse

    2015-01-01

    Mixtures of xenon and molecular hydrogen form a series of hexagonal, van der Waals compounds at high pressures and at 300 K. Synchrotron, x-ray, single crystal diffraction studies reveal that below 7.5 GPa, Xe(H 2 ) 8 crystallizes in a P3 - m1 structure that displays pressure-induced occupancy changes of two pairs of xenon atoms located on the 2c and 2d sites (while the third pair on yet another 2c site remains fully occupied). The occupancy becomes 1 at the P3 - m1 to R3 transition and all the xenon atoms occupy the 3d sites in the high-pressure structure. These pressure-induced changes in occupancy coincide with volume changes that maintain the average Xe:H 2 stoichiometry fixed at 1:8. The synchrotron x-ray diffraction and Raman measurements show that this unique hydrogen-bearing compound that can be synthesized at 4.2 GPa and 300 K, quenched at low temperatures to atmospheric pressure, and retained up to 90 K on subsequent warming

  10. Xe N4,5O-OOO satellite Auger spectrum

    International Nuclear Information System (INIS)

    Partanen, L; Huttula, M; Heinaesmaeki, S; Aksela, H; Aksela, S

    2007-01-01

    The N 4,5 O 1,2,3 -O 1,2,3 O 2,3 O 2,3 Auger transitions, appearing as a satellite structure in the N 4,5 -OO Auger spectrum of xenon, were studied in detail. By measuring the N 4,5 O-OOO satellite Auger spectrum both below and above the 4p ionization threshold, we were able to separate the satellite production via the direct photo-double ionization and the Auger cascade from the 4p states. The N 3 -N 4,5 O 2,3 Coster-Kronig transitions and the subsequent N 4,5 O 2,3 -O 2,3 O 2,3 O 2,3 satellite Auger transitions were calculated using the HF wavefunctions and the most intense satellite lines were assigned. The Xe N 4,5 O-OOO satellite spectrum was compared with the previously studied Kr M 4,5 N-NNN satellite Auger spectrum. The 5s orbital in Xe was found to reveal more pronounced electron correlation than the 4s orbital in Kr

  11. Negligible fractionation of Kr and Xe isotopes by molecular diffusion in water

    Science.gov (United States)

    Tyroller, Lina; Brennwald, Matthias S.; Busemann, Henner; Maden, Colin; Baur, Heinrich; Kipfer, Rolf

    2018-06-01

    Molecular diffusion is a key transport process for noble gases in water. Such diffusive transport is often thought to cause a mass-dependent fractionation of noble gas isotopes that is inversely proportional to the square root of the ratio of their atomic mass, referred to as the square root relation. Previous studies, challenged the commonly held assumption that the square root relation adequately describes the behaviour of noble gas isotopes diffusing through water. However, the effect of diffusion on noble gas isotopes has only been determined experimentally for He, Ne and Ar to date, whereas the extent of fractionation of Kr and Xe has not been measured. In the present study the fractionation of Kr and Xe isotopes diffusing through water immobilised by adding agar was quantified through measuring the respective isotope ratio after diffusing through the immobilised water. No fractionation of Kr and Xe isotopes was observed, even using high-precision noble gas analytics. These results complement our current understanding on isotopic fractionation of noble gases diffusing through water. Therefore this complete data set builds a robust basis to describe molecular diffusion of noble gases in water in a physical sound manner which is fundamental to assess the physical aspects of gas dynamics in aquatic systems.

  12. Generation of metallic arc spectrum of pumping discharge of XeCl laser; XeCl ekishima laser reiki hoden ni okeru arc iko to kinzoku supekutoru no hassei

    Energy Technology Data Exchange (ETDEWEB)

    Koike, H.; Yukimura, K. [Doshisha University, Kyoto (Japan)

    1997-12-20

    An arc generation of a long-pulse spiker-sustainer excimer laser with about 250ns of pulse width , is discussed by using time-varying spectroscopic method. First arcing occurs during a main discharge for laser excitation and shows XeII spectrum, while a glow-like discharge represents only XeI spectrum, the metallic spectrum such as Nil caused by vaporization of electrode material begins to appear just after the termination of the main discharge. Second arcing occurs after about 2{mu}s, which brings strong intensity of Nil spectrum. It means that the reignition arc might be produced in a metallic vapor that appears during the main discharge. Accordingly, it is concluded that the reignition arc is inherently metallic, which is different from the main arc with rare gas plasma. 9 refs., 9 figs.

  13. Radiopharmacology of inhaled [sup 133]Xe in skeletal sites containing deposits of Gaucher cells

    Energy Technology Data Exchange (ETDEWEB)

    Castronovo, F.P. Jr. (Brigham and Women' s Hospital, Boston, MA (United States) Harvard Medical School, Boston, MA (United States)); McKusick, K.A.; Doppelt, S.H. (Massachusetts General Hospital, Boston, MA (United States) Harvard Medical School, Boston, MA (United States)); Barton, N.W. (National Insts. of Health, Bethesda, MD (United States))

    1993-07-01

    Gaucher's disease is a lysomal storage disease in which cells of the reticuloendothelial system accumulate the lipid glucocerebroside. It is characterized by slowly progressive visceral and osseous involvement. One of the latter manifestations includes lipid infiltration of bone marrow. We monitored the rate of the inhaled [sup 133]Xe uptake and wash-out over diseased and normal metaphyseal and epiphyseal areas of the knee. Twenty-two patients (15 adults, 7 children) with various degrees of previously diagnosed Gaucher's disease were positioned supine under a [gamma]-camera interfaced to a computer system. All patients rebreathed [sup 133]Xe gas from a closed system for 10 min followed by 14 min of wash-out. Digitized images of the lung, liver, spleen, bony sites and soft tissue were obtained at 1 min intervals during the wash-in and wash-out phases. Counts for each ROI were normalized per 100 pixels and plotted as a function (time). Maximum uptake was also calculated by relating the counts/ROI/100 pixels to the 10 min integrated lung count during equilibrium (the administered ''dose''). There was essentially no [sup 133]Xe uptake in liver and spleen involved with Gaucher's disease. Monophasic uptake and biphasic wash-out curves were observed in the limited investigative population. Gaucher deposits released the [sup 133]Xe at a greater rate relative to soft tissue. (Author).

  14. Xe-135 and Sm-149 Isotopic Evolution Analysis Xesamo code; Analisis de la Evolucion Isotopica del Xe-135 y Sm-149. Programa Xesamo

    Energy Technology Data Exchange (ETDEWEB)

    Caro, R; Gallego, J; Martinez Fanegas, R

    1977-07-01

    In this report the time evolution analysis of the nuclides concentration Xe-135 and Sm-149 as a function of the neutron flux is carried out. The neutron flux may be any function of time. It is analyzed as well the reactivity changes associated with the xenon and samarium concentration variations. (Author) 5 refs.

  15. Study of temperature and radiation induced microstructural changes in Xe-implanted UO2 by TEM, STEM, SIMS and positron spectroscopy

    International Nuclear Information System (INIS)

    Djourelov, Nikolay; Marchand, Benoît; Marinov, Hristo; Moncoffre, Nathalie; Pipon, Yves; Bérerd, Nicolas; Nédélec, Patrick; Raimbault, Louis; Epicier, Thierry

    2013-01-01

    Doppler broadening of annihilation gamma-line combined with a slow positron beam (SPB) was used to measure the momentum density distribution of annihilating pairs in a set of sintered UO 2 samples implantated with 800-keV 136 Xe 2+ at fluences of 1 × 10 15 and 1 × 10 16 Xe cm −2 . The effect of prolonged post-implantation annealing at 1673 and 1873 K, grain size, and 152-MeV Iodine irradiation were studied by analysis of S(E) profiles and S-W maps and discussed versus secondary ion mass spectroscopy (SIMS), scanning transmission electron microscopy results. Spectroscopy with SPB and SIMS is an excellent combination of complementary techniques for studying the formation and evolution of Xe-bubbles, and Xe retention

  16. Collective states of even Xe isotopes in IBM+MQRPA

    Directory of Open Access Journals (Sweden)

    Efimov A. D.

    2016-01-01

    Full Text Available A modification of the Quasiparticle Random Phase Approximation (QRPA with small ground state correlations is suggested. The lowest energy phonon is used as the image of d-boson of the Interacting Boson Model 1 (IBM1 and applied to microscopical calculations of the IBM1 parameters. Results are compared with experimental data for Xe isotopes.

  17. Boltzmann equation analysis of electrons swarm parameters and properties of excited particle number densities in Xe/Ne plasmas. Laser absorption effect; Xe/Ne plasma chudenshi yuso keisu narabi ni reiki ryushisu mitsudo tokusei no Boltzmann hoteishiki kaiseki. Laser ko kyushu koka

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, S.; Sugawara, H.; Ventzek, P.; Sakai, Y. [Hokkaido University, Sapporo (Japan)

    1998-06-01

    Xe/Ne plasmas are important for plasma display panels and VUV light sources. However, reactions between electrons and excited particles in the mixtures are so complicated that influence of the reactions on the plasma properties is not understood well. In this work, taking account of reactions through which electrons are produced, such as cumulative and Penning ionization, and of transition between excited levels, the electron and excited particle properties in Xe/Ne plasmas are calculated using the Boltzmann equation. The ionization coefficient and electron drift velocity agreed with experimental data. The influence of laser absorption in Xe/Ne plasmas on the plasma properties is also discussed. 25 refs., 15 figs.

  18. Infrared Spectra of Novel NgBeSO2 Complexes (Ng = Ne, Ar, Kr, Xe) in Low Temperature Matrixes.

    Science.gov (United States)

    Yu, Wenjie; Liu, Xing; Xu, Bing; Xing, Xiaopeng; Wang, Xuefeng

    2016-11-03

    The novel noble-gas complexes NgBeSO 2 (Ng = Ne, Ar, Kr, Xe) have been prepared in the laser-evaporated beryllium atom reactions with SO 2 in low-temperature matrixes. Doped with heavier noble gas, the guest (Ar, Kr, Xe) atom can substitute neon to form more stable complex. Infrared spectroscopy and theoretical calculations are used to confirm the band assignment. The dissociation energies are calculated at 0.9, 4.0, 4.7, and 6.0 kcal/mol for NeBeSO 2 , ArBeSO 2 , KrBeSO 2 , and XeBeSO 2 , respectively, at the CCSD(T) level. Quantum chemical calculations demonstrate that the Ng-Be bonds in NgBeSO 2 could be formed by the combination of electron-donation and ion-induced dipole interactions. The Wiberg bond index (WBI) values of Ng-Be bonds and LOL (localized orbital locator) profile indicate that the Ng-Be bond exhibits a gradual increase in covalent character along Ne to Xe.

  19. Spectral and temporal characteristics of target current and electromagnetic pulse induced by nanosecond laser ablation

    Czech Academy of Sciences Publication Activity Database

    Krása, Josef; De Marco, Massimo; Cikhardt, Jakub; Pfeifer, Miroslav; Velyhan, Andriy; Klír, Daniel; Řezáč, Karel; Limpouch, J.; Krouský, Eduard; Dostál, Jan; Ullschmied, Jiří; Dudžák, Roman

    2017-01-01

    Roč. 59, č. 6 (2017), 1-8, č. článku 065007. ISSN 0741-3335 R&D Projects: GA MŠk EF15_008/0000162; GA ČR GA16-07036S EU Projects: European Commission(XE) 654148 - LASERLAB-EUROPE Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 ; RVO:61389021 Keywords : laser-produced plasma * target current * electromagnetic pulse Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 2.392, year: 2016

  20. Evaluation of a multi-marker immunomagnetic enrichment assay for the quantification of circulating melanoma cells

    Directory of Open Access Journals (Sweden)

    Freeman James B

    2012-09-01

    Full Text Available Abstract Background Circulating melanoma cells (CMCs are thought to be valuable in improving measures of prognosis in melanoma patients and may be a useful marker of residual disease to identify non-metastatic patients requiring adjuvant therapy. We investigated whether immunomagnetic enrichment targeting multiple markers allows more efficient enrichment of CMCs from patient peripheral blood than targeting a single marker. Furthermore, we aimed to determine whether the number of CMCs in patient blood was associated with disease stage. Methods We captured CMCs by targeting the melanoma associated markers MCSP and MCAM as well as the melanoma stem cell markers ABCB5 and CD271, both individually and in combination, by immunomagnetic enrichment. CMCs were enriched and quantified from the peripheral blood of 10 non-metastatic and 13 metastatic melanoma patients. Results Targeting all markers in combination resulted in the enrichment of more CMCs than when any individual marker was targeted (p  Conclusions Our results demonstrated that a combination of markers should be targeted for optimal isolation of CMCs. In addition, there are significantly more CMCs in metastatic patients compared with non-metastatic patients and therefore quantification of CMCs may prove to be a useful marker of disease progression.

  1. The miR-124 family of microRNAs is crucial for regeneration of the brain and visual system in the planarian Schmidtea mediterranea.

    Science.gov (United States)

    Sasidharan, Vidyanand; Marepally, Srujan; Elliott, Sarah A; Baid, Srishti; Lakshmanan, Vairavan; Nayyar, Nishtha; Bansal, Dhiru; Sánchez Alvarado, Alejandro; Vemula, Praveen Kumar; Palakodeti, Dasaradhi

    2017-09-15

    Brain regeneration in planarians is mediated by precise spatiotemporal control of gene expression and is crucial for multiple aspects of neurogenesis. However, the mechanisms underpinning the gene regulation essential for brain regeneration are largely unknown. Here, we investigated the role of the miR-124 family of microRNAs in planarian brain regeneration. The miR-124 family ( miR-124 ) is highly conserved in animals and regulates neurogenesis by facilitating neural differentiation, yet its role in neural wiring and brain organization is not known. We developed a novel method for delivering anti-miRs using liposomes for the functional knockdown of microRNAs. Smed-miR-124 knockdown revealed a key role for these microRNAs in neuronal organization during planarian brain regeneration. Our results also demonstrated an essential role for miR-124 in the generation of eye progenitors. Additionally, miR-124 regulates Smed-slit-1 , which encodes an axon guidance protein, either by targeting slit-1 mRNA or, potentially, by modulating the canonical Notch pathway. Together, our results reveal a role for miR-124 in regulating the regeneration of a functional brain and visual system. © 2017. Published by The Company of Biologists Ltd.

  2. [Hydrogen bis(1,2,4-triazole] 1,2,4-triazolium bis(3-carboxy-4-hydroxybenzenesulfonate 1,2,4-triazole disolvate

    Directory of Open Access Journals (Sweden)

    Ming-qiang Qiu

    2010-08-01

    Full Text Available The title compound, C2H4N3+·[H(C2H3N32]+·2C7H5O6S−·2C2H3N3, consists of two types of 1,2,4-triazole monocation, one protonated at the 2-site lying across a twofold axis and the other protonated at the 4-site with the H atom disordered over a center of symmetry, a 5-sulfosalicylate anion and a neutral 1,2,4-triazole molecule. The component ions are linked into a three-dimensional network by a combination of N—H...O, N—H...N, O—H...O, O—H...N, C—H...O and C—H...N hydrogen bonds. In addition, benzene–benzene π–π interactions of 3.942 (2 Å [interplanar spacing = 3.390 (2 Å] and C—O...π (3.331 Å interactions are observed.

  3. Determination of electronic stopping powers of 0.05–1 MeV/u {sup 131}Xe ions in C-, Ni- and Au-absorbers with calorimetric low temperature detectors

    Energy Technology Data Exchange (ETDEWEB)

    Echler, A., E-mail: artur.echler@iamp.physik.uni-giessen.de [GSI Helmholtz Center for Heavy Ion Research, Darmstadt (Germany); Institute for Atomic and Molecular Physics, University of Giessen (Germany); Institute for Physics, University of Mainz (Germany); Egelhof, P.; Grabitz, P. [GSI Helmholtz Center for Heavy Ion Research, Darmstadt (Germany); Institute for Physics, University of Mainz (Germany); Kettunen, H. [Department of Physics, University of Jyväskylä (Finland); Kraft-Bermuth, S. [Institute for Atomic and Molecular Physics, University of Giessen (Germany); Laitinen, M. [Department of Physics, University of Jyväskylä (Finland); Müller, K. [Institute for Atomic and Molecular Physics, University of Giessen (Germany); Rossi, M.; Trzaska, W.H.; Virtanen, A. [Department of Physics, University of Jyväskylä (Finland)

    2017-01-15

    A new experimental system for precise determination of electronic stopping powers of heavy ions has been set up at the accelerator laboratory of the University of Jyväskylä. The new setup, combining an established B-ToF system and an array of calorimetric low temperature detectors (CLTDs), has been used for the determination of electronic stopping powers of 0.05–1 MeV/u {sup 131}Xe ions in carbon, nickel and gold. Thereby advantage of the improved linearity and energy resolution of CLTDs as compared to the previously used ionization detector was taken to reduce energy calibration errors and to increase sensitivity for the energy loss determination, in particular at very low energies. The total uncertainties of 3–4% for C- and Ni-targets, and 5–7% for Au-targets, respectively, are dominated by the target properties, i.e. thickness determination and inhomogeneities. The results are compared to data from literature and to predictions of different theoretical computer codes. In the high energy part of the examined energy range the results are in good agreement with previously published data, while new stopping power data for very heavy ions in different Z{sub 2}-materials have been obtained at lower energies. Moreover, unexpectedly strong channeling effects for the transmission of the {sup 131}Xe ions in thin, partly polycrystalline nickel and gold target foils have been observed and investigated.

  4. XeF pump laser. Final technical report

    International Nuclear Information System (INIS)

    1980-03-01

    The goal of this program was to demonstrate operation of an XeF laser of adequate energy, efficiency and beam quality at high repetition rates. The specific design goals were: PRF greater than or equal to 10 kHz, energy output greater than or equal to 50 mJ/pulse, efficiency greater than or equal to 0.3%, and beam divergence angle less than or equal to 20x diffraction limited. In the following sections of this report we will discuss how these goals have been met

  5. Positive responses of belowground C dynamics to nitrogen enrichment in China.

    Science.gov (United States)

    Deng, Lei; Peng, Changhui; Zhu, Guangyu; Chen, Lei; Liu, Yulin; Shangguan, Zhouping

    2018-03-01

    Determining how nitrogen (N) impacts ecosystem carbon (C) cycling is critical to using C sequestration to offset anthropogenic CO 2 emissions. The N deposition rate in China is higher than the global average; however, many results of N enrichment experiments in China have not been included in global syntheses. In this study, we assembled a large dataset that comprised 124 published studies concerning N addition experiments, including 570 observations at 127 sites across China, to quantify the responses of belowground C dynamics to N enrichment in terrestrial ecosystems in China by a meta-analysis. The results showed that overall soil organic C, dissolved organic C (DOC) and soil microbial biomass C (MBC) increased by 1.8, 7.4, and 8.8%, respectively (Penrichment; belowground biomass and litter increased by 14.6 and 24.4%, respectively (Penrichment promoted C inputs into the soil mainly by increasing litter and belowground biomass inputs. Additionally, N enrichment increased C output by increasing soil respiration. Land use type and N addition level had different impacts on the soil C pool and on soil respiration. DOC, MBC, and litter exhibited more positive responses to N deposition in cooler and more arid regions than in other regions. The meta-analysis indicated that N enrichment had a positive impact on belowground C cycles in China. Climate played a greater role than did N deposition level in affecting processes of ecosystem C cycling. Moreover, belowground C cycle processes are determined by complicated interactions among land use type, N enrichment, and climate. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Rearrangement of valence neutrons in the neutrinoless double-β decay of 136Xe

    Science.gov (United States)

    Szwec, S. V.; Kay, B. P.; Cocolios, T. E.; Entwisle, J. P.; Freeman, S. J.; Gaffney, L. P.; Guimarães, V.; Hammache, F.; McKee, P. P.; Parr, E.; Portail, C.; Schiffer, J. P.; de Séréville, N.; Sharp, D. K.; Smith, J. F.; Stefan, I.

    2016-11-01

    A quantitative description of the change in ground-state neutron occupancies between 136Xe and 136Ba, the initial and final state in the neutrinoless double-β decay of 136Xe, has been extracted from precision measurements of the cross sections of single-neutron-adding and -removing reactions. Comparisons are made to recent theoretical calculations of the same properties using various nuclear-structure models. These are the same calculations used to determine the magnitude of the nuclear matrix elements for the process, which at present disagree with each other by factors of 2 or 3. The experimental neutron occupancies show some disagreement with the theoretical calculations.

  7. Hybridization Capture Using Short PCR Products Enriches Small Genomes by Capturing Flanking Sequences (CapFlank)

    DEFF Research Database (Denmark)

    Tsangaras, Kyriakos; Wales, Nathan; Sicheritz-Pontén, Thomas

    2014-01-01

    , a non-negligible fraction of the resulting sequence reads are not homologous to the bait. We demonstrate that during capture, the bait-hybridized library molecules add additional flanking library sequences iteratively, such that baits limited to targeting relatively short regions (e.g. few hundred...... nucleotides) can result in enrichment across entire mitochondrial and bacterial genomes. Our findings suggest that some of the off-target sequences derived in capture experiments are non-randomly enriched, and that CapFlank will facilitate targeted enrichment of large contiguous sequences with minimal prior...

  8. The 2017 Xe run at CERN Linac3: measurements and beam dynamics simulations

    CERN Document Server

    Benedetti, Stefano; Kuchler, Detlef; Lombardi, Alessandra; Wenander, Fredrik John Carl; Toivanen, Ville Aleksi; CERN. Geneva. ATS Department

    2018-01-01

    At CERN quark-gluon plasma and fixed target ion experiments are performed thanks to the Heavy-ion Facility, composed by different accelerators. The starting point is CERN Linac3, which delivers 4.2 MeV/u ion beams to the Low Energy Ion Ring (LEIR). In 2017 Linac3 accelerated Xe instead of the most usual Pb. Machine development (MD) time was allocated to adapt the accelerator to the new ion species. This article summarizes the measurements performed during the MD time allocated to characterize the line from the source to the filtering section. A parallel effort was devoted to match those measurements to the beam dynamics simulations, and the second part of the article highlights the results achieved in this regard. Thanks to the improved understanding of the machine critical areas, a list of possible improvements is proposed at the end.

  9. Measurement of the Auger decay after resonance excitation of Xe 4d and Kr 3d resonance lines

    International Nuclear Information System (INIS)

    Eberhardt, W.; Kalkoffen, G.; Kunz, C.

    1978-03-01

    The Nsub(4,5) 0sub(2,3) 0sub(2,3) Auger spectra from Xe and the Msub(4,5) Nsub(2,3) Nsub(2,3) Auger spectra from Kr are investigated for different photon energies around threshold of ionization. When exciting at the resonance line (4d 9 5s 2 5p 6 6p for Xe and 3d 9 4s 2 4p 6 5p for Kr) we observe the usual Auger multiplet structure to be shifted to higher kinetic energies. Additionally, new lines appear which can be assigned to shake-up processes int he Xe + and Kr + ions. (orig.) [de

  10. Synchrotron x-ray-diffraction study of the structure and growth of Xe films adsorbed on the Ag(111) surface

    International Nuclear Information System (INIS)

    Dai, P.; Wu, Z.; Angot, T.; Wang, S.; Taub, H.; Ehrlich, S.N.

    1999-01-01

    Synchrotron x-ray scattering has been used to investigate the structure and growth of perhaps the simplest of all films: xenon physisorbed on the Ag(111) surface. High-resolution x-ray scans of the in-plane structure and lower-resolution scans (specular and nonspecular) of the out-of-plane order were performed. The Xe films were prepared under both quasiequilibrium and kinetic growth conditions, and have fewer structural defects than those investigated previously by others on graphite substrates. Under quasiequilibrium conditions, the bulk Xe-Xe spacing is reached at monolayer completion, and the monolayer and bilayer lattice constants at coexistence are inferred equal to within 0.005 Angstrom, consistent with theoretical calculations. The Xe/vacuum interface profile for a complete monolayer and bilayer grown at quasiequilibrium is found to be sharper than for kinetically grown films. At coverages above two layers, diffraction scans along the Xe(01l) rod for quasiequilibrated films are consistent with the presence of two domains having predominantly an ABC stacking sequence and rotated 60 degree with respect to each other about the surface normal. Annealing of these films alters neither the population of the two domains nor the fraction of ABA stacking faults. The thickest film grown under quasiequilibrium conditions exceeds 220 Angstrom (resolution limited). Under kinetic growth conditions, x-ray intensity oscillations at the Xe anti-Bragg position of the specular rod are observed as a function of time, indicating nearly layer-by-layer growth. Up to four complete oscillations corresponding to a film of eight layers have been observed before the intensity is damped out; the number of oscillations is found to depend on the substrate temperature, the growth rate, and the quality of the Ag(111) substrate. The specular reflectivity from kinetically grown films at nominal coverages of three and four layers has been analyzed using a Gaussian model which gives a film

  11. Ventilation abnormalities in obstructive airways disorder. Detection with pulmonary dynamic densitometry by means of spinal CT versus dynamic Xe-133 SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Nishigauchi, Kazuya; Kume, Norihiko; Takana, Katsuyuki; Koike, Shinji; Shimizu, Kensaku; Matsunaga, Naofumi

    1999-01-01

    The usefulness of pulmonary dynamic densitometry (PDD) acquired by spiral computed tomography (CT) to detect ventilation abnormalities in obstructive airway disorders was evaluated in comparison with dynamic xenon-133 (Xe-133) SPECT. Eight-second, continuous spiral CT scan was performed over 2-3 respiratory cycles in six healthy volunteers, 19 patients with airways disorder, and six patients with restrictive lung disease. The data set were reconstructed as 36 one-second temporally overlapping images at 0.2-second intervals, and regional PDD curves were displayed. Regional ventilation was assessed by Xe-133 clearance-time on Xe-133 SPECT. Normal lungs showed smooth, sinusoidal PDD curves with maximal amplitude in lung attenuation change (MALAC) of 54.9+24.5 HU; whereas, obstructive airways disorders with prolonged Xe-133 clearance showed significantly diminished MALAC (31.6+20.1 HU, P<0.0001), accompanied by irregularity, asynchronous phase, and deterioration of normal ventral-to-dorsal gradients in MALAC and lung attenuation. Restrictive diseases without prolonged Xe-133 clearance did not show statistically significant reduction in MALAC. In total 251 lung regions, regional MALAC correlated inversely with Xe-133 clearance-time (r=842). PDD acquired by spiral CT is acceptable for detecting ventilation abnormalities in obstructive airways disorder. (author)

  12. I-Xe and 40Ar-39Ar analyses of silicate from the Eagle Station pallasite and the anomalous iron meteorite Enon

    International Nuclear Information System (INIS)

    Niemeyer, S.

    1983-01-01

    Silicate from two unusual iron-rich meteorites were analyzed by the I-Xe and 40 Ar- 39 Ar techniques. Enon, an anomalous iron meteorite with chondritic silicate, shows no loss of radiogenic 40 Ar at low temperature, and gives a plateau age of 4.59 +- 0.03 Ga. Although the Xe data fail to define an I-Xe correlation the inferred Pu/U ratio is more than 2 σ above the chondritic value, and the Pu abundance derived from the concentration of Pu-fission Xe is 6 times greater than the abundance inferred for CI meteorites. These findings for Enon, coupled with data for IAB iron meteorites, suggest that presence of chondritic silicate in an iron-rich meteorite is diagnostic of an old radiometric age with little subsequent thermal disturbance. The Eagle Station pallasite, the most 16 O-rich meteorite known, gives a complex 40 Ar- 39 Ar age pattern which suggests a recent severe thermal disturbance. The absence of excess 129 Xe, and the low trapped Ar and Xe contents, are consistent with this interpretation. The similarity between 40 Ar- 39 Ar data for Eagle Station and for the olivine-rich meteorite Chassigny lends credence to the previous suggestion of a connection between Chassigny and pallasites. (author)

  13. Quantitative mass spectrometric analysis of glycoproteins combined with enrichment methods.

    Science.gov (United States)

    Ahn, Yeong Hee; Kim, Jin Young; Yoo, Jong Shin

    2015-01-01

    Mass spectrometry (MS) has been a core technology for high sensitive and high-throughput analysis of the enriched glycoproteome in aspects of quantitative assays as well as qualitative profiling of glycoproteins. Because it has been widely recognized that aberrant glycosylation in a glycoprotein may involve in progression of a certain disease, the development of efficient analysis tool for the aberrant glycoproteins is very important for deep understanding about pathological function of the glycoprotein and new biomarker development. This review first describes the protein glycosylation-targeting enrichment technologies mainly employing solid-phase extraction methods such as hydrizide-capturing, lectin-specific capturing, and affinity separation techniques based on porous graphitized carbon, hydrophilic interaction chromatography, or immobilized boronic acid. Second, MS-based quantitative analysis strategies coupled with the protein glycosylation-targeting enrichment technologies, by using a label-free MS, stable isotope-labeling, or targeted multiple reaction monitoring (MRM) MS, are summarized with recent published studies. © 2014 The Authors. Mass Spectrometry Reviews Published by Wiley Periodicals, Inc.

  14. A new search for the atomic EDM of {sup 129}Xe at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Kuchler, F., E-mail: florian.kuchler@tum.de [Excellence Cluster Universe and Technische Universität München (Germany); Babcock, E. [Juelich Center for Neutron Science (Germany); Burghoff, M. [Physikalisch-Technische Bundesanstalt (Germany); Chupp, T.; Degenkolb, S. [University of Michigan (United States); Fan, I. [Physikalisch-Technische Bundesanstalt (Germany); Fierlinger, P. [Excellence Cluster Universe and Technische Universität München (Germany); Gong, F. [University of Michigan (United States); Kraegeloh, E. [Excellence Cluster Universe and Technische Universität München (Germany); Kilian, W.; Knappe-Grüneberg, S. [Physikalisch-Technische Bundesanstalt (Germany); Lins, T.; Marino, M.; Meinel, J.; Niessen, B. [Excellence Cluster Universe and Technische Universität München (Germany); Sachdeva, N. [University of Michigan (United States); Salhi, Z. [Juelich Center for Neutron Science (Germany); Schnabel, A.; Seifert, F. [Physikalisch-Technische Bundesanstalt (Germany); Singh, J. [Michigan State University and NSCL (United States); and others

    2016-12-15

    Permanent electric dipole moments (EDMs) arise due to the breaking of time-reversal or, equivalently, CP-symmetry. Although EDM searches have so far only set upper limits, which are many orders of magnitude larger than Standard Model (SM) predictions, the motivation for more sensitive searches is stronger than ever. A new effort at FRM-II incorporating {sup 129}Xe and {sup 3}He as a co-magnetometer can potentially improve the current limit. The noble gas mixture of {sup 129}Xe and {sup 3}He is simultanously polarized by spin-exchange optical pumping and then transferred into a high-performance magnetically shielded room. Inside, both species can freely precess in the presence of applied magnetic and electric fields. The precession signals are detected by LTc SQUID sensors. In EDM cells with silicon electrodes we observed spin lifetimes in excess of 2500 s without and with high-voltage applied. This meets one requirement to achieve our goal of improving the EDM limit on {sup 129}Xe by several orders of magnitude.

  15. 'Clickable' hydrosoluble PEGylated cryptophane as a universal platform for 129Xe magnetic resonance imaging biosensors

    International Nuclear Information System (INIS)

    Delacour, Lea; Kotera, Naoko; Traore, Tenin; Garcia-Argote, Sebastien; Puente, Celine; Gravel, Edmond; Rousseau, Bernard; Leteurtre, Francois; Boulard, Yves; Tassali, Nawal; Boutin, Celine; Leonce, Estelle; Berthault, Patrick

    2013-01-01

    We describe the synthesis of a highly water-soluble cryptophane 1 that can be seen as a universal platform for the construction of 129 Xe magnetic resonance imaging (MRI)-based biosensors. Compound 1 is easily functionalized by Huisgen cycloaddition and exhibits excellent xenon-encapsulation properties. In addition, 1 is nontoxic at the concentrations typically used for hyper-polarized 129 Xe MRI. (authors)

  16. Ultralow energy calibration of LUX detector using Xe 127 electron capture

    Science.gov (United States)

    Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Brás, P.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Druszkiewicz, E.; Edwards, B. N.; Fallon, S. R.; Fan, A.; Fiorucci, S.; Gaitskell, R. J.; Genovesi, J.; Ghag, C.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Velan, V.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.

    2017-12-01

    We report an absolute calibration of the ionization yields (Qy ) and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V /cm . The data are obtained using low energy Xe 127 electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of weakly interacting massive particles. The sequence of gamma-ray and x-ray cascades associated with I 127 deexcitations produces clearly identified two-vertex events in the LUX detector. We observe the K-(binding energy, 33.2 keV), L-(5.2 keV), M-(1.1 keV), and N-(186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil in situ measurements that have been explored in liquid xenon.

  17. Far From ‘Easy’ Spectroscopy with the 8π and GRIFFIN Spectrometers at TRIUMF-ISAC

    Science.gov (United States)

    Garrett, P. E.; Radich, A. J.; Allmond, J. M.; Andreoiu, C.; Ball, G. C.; Bender, P. C.; Bianco, L.; Bildstein, V.; Bidaman, H.; Braid, R.; Burbadge, C.; Chagnon-Lessard, S.; Cross, D. S.; Deng, G.; Demand, G. A.; Diaz Varela, A.; Dunlop, M. R.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Ilyushkin, S.; Jigmeddorj, B.; Kisliuk, D.; Kuhn, K.; Laffoley, A. T.; Leach, K. G.; MacLean, A. D.; Michetti-Wilson, J.; Miller, D.; Moore, W.; Olaizola, B.; Orce, J. N.; Pearson, C. J.; Pore, J. L.; Rajabali, M. M.; Rand, E. T.; Sarazin, F.; Smith, J. K.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Turko, J.; Wang, Z. M.; Wood, J. L.; Wong, J.; Williams, S. J.; Yates, S. W.; Zganjar, E. F.

    2015-09-01

    The 8π spectrometer, installed at the TRIUMF-ISAC facility, was the world's most sensitive γ-ray spectrometer dedicated to β-decay studies. A description is given of the 8π spectrometer and its auxiliary detectors including the plastic scintillator array SCEPTAR used for β-particle tagging and the Si(Li) array PACES for conversion electron measurements, its moving tape collector, and its data acquisition system. The recent investigation of the decay of 124Cs to study the nuclear structure of 124Xe, and how the β-decay measurements complemented previous Coulomb excitation studies, is highlighted, including the extraction of the deformation parameters for the excited 0+ bands in 124Xe. As a by-product, the decay scheme of the (7+) 124Cs isomeric state, for which the data from the PACES detectors were vital, was studied. Finally, a description of the new GRIFFIN spectrometer, which uses the same auxiliary detectors as the 8π spectrometer, is given.

  18. Deep inelastic scattering near the Coulomb barrier

    International Nuclear Information System (INIS)

    Gehring, J.; Back, B.; Chan, K.

    1995-01-01

    Deep inelastic scattering was recently observed in heavy ion reactions at incident energies near and below the Coulomb barrier. Traditional models of this process are based on frictional forces and are designed to predict the features of deep inelastic processes at energies above the barrier. They cannot be applied at energies below the barrier where the nuclear overlap is small and friction is negligible. The presence of deep inelastic scattering at these energies requires a different explanation. The first observation of deep inelastic scattering near the barrier was in the systems 124,112 Sn + 58,64 Ni by Wolfs et al. We previously extended these measurements to the system 136 Xe + 64 Ni and currently measured the system 124 Xe + 58 Ni. We obtained better statistics, better mass and energy resolution, and more complete angular coverage in the Xe + Ni measurements. The cross sections and angular distributions are similar in all of the Sn + Ni and Xe + Ni systems. The data are currently being analyzed and compared with new theoretical calculations. They will be part of the thesis of J. Gehring

  19. Combination with a defucosylated anti-HM1.24 monoclonal antibody plus lenalidomide induces marked ADCC against myeloma cells and their progenitors.

    Directory of Open Access Journals (Sweden)

    Takeshi Harada

    Full Text Available The immunomodulatory drug lenalidomide (Len has drawn attention to potentiate antibody-dependent cellular cytotoxicity (ADCC-mediated immunotherapies. We developed the defucosylated version (YB-AHM of humanized monoclonal antibody against HM1.24 (CD317 overexpressed in multiple myeloma (MM cells. In this study, we evaluated ADCC by YB-AHM and Len in combination against MM cells and their progenitors. YB-AHM was able to selectively kill via ADCC MM cells in bone marrow samples from patients with MM with low effector/target ratios, which was further enhanced by treatment with Len. Interestingly, Len also up-regulated HM1.24 expression on MM cells in an effector-dependent manner. HM1.24 was found to be highly expressed in a drug-resistant clonogenic "side population" in MM cells; and this combinatory treatment successfully reduced SP fractions in RPMI 8226 and KMS-11 cells in the presence of effector cells, and suppressed a clonogenic potential of MM cells in colony-forming assays. Collectively, the present study suggests that YB-AHM and Len in combination may become an effective therapeutic strategy in MM, warranting further study to target drug-resistant MM clonogenic cells.

  20. Music for the birds: effects of auditory enrichment on captive bird species.

    Science.gov (United States)

    Robbins, Lindsey; Margulis, Susan W

    2016-01-01

    With the increase of mixed species exhibits in zoos, targeting enrichment for individual species may be problematic. Often, mammals may be the primary targets of enrichment, yet other species that share their environment (such as birds) will unavoidably be exposed to the enrichment as well. The purpose of this study was to determine if (1) auditory stimuli designed for enrichment of primates influenced the behavior of captive birds in the zoo setting, and (2) if the specific type of auditory enrichment impacted bird behavior. Three different African bird species were observed at the Buffalo Zoo during exposure to natural sounds, classical music and rock music. The results revealed that the average frequency of flying in all three bird species increased with naturalistic sounds and decreased with rock music (F = 7.63, df = 3,6, P = 0.018); vocalizations for two of the three species (Superb Starlings and Mousebirds) increased (F = 18.61, df = 2,6, P = 0.0027) in response to all auditory stimuli, however one species (Lady Ross's Turacos) increased frequency of duetting only in response to rock music (X(2) = 18.5, df = 2, P < 0.0001). Auditory enrichment implemented for large mammals may influence behavior in non-target species as well, in this case leading to increased activity by birds. © 2016 Wiley Periodicals, Inc.

  1. Nociceptor-Enriched Genes Required for Normal Thermal Nociception

    Directory of Open Access Journals (Sweden)

    Ken Honjo

    2016-07-01

    Full Text Available Here, we describe a targeted reverse genetic screen for thermal nociception genes in Drosophila larvae. Using laser capture microdissection and microarray analyses of nociceptive and non-nociceptive neurons, we identified 275 nociceptor-enriched genes. We then tested the function of the enriched genes with nociceptor-specific RNAi and thermal nociception assays. Tissue-specific RNAi targeted against 14 genes caused insensitive thermal nociception while targeting of 22 genes caused hypersensitive thermal nociception. Previously uncategorized genes were named for heat resistance (i.e., boilerman, fire dancer, oven mitt, trivet, thawb, and bunker gear or heat sensitivity (firelighter, black match, eucalyptus, primacord, jet fuel, detonator, gasoline, smoke alarm, and jetboil. Insensitive nociception phenotypes were often associated with severely reduced branching of nociceptor neurites and hyperbranched dendrites were seen in two of the hypersensitive cases. Many genes that we identified are conserved in mammals.

  2. Reproducibility of estimation of blood flow in the human masseter muscle from measurements of 133Xe clearance

    International Nuclear Information System (INIS)

    Monteiro, A.A.; Kopp, S.

    1989-01-01

    The reproducibility of estimations of the masseter intramuscular blood flow (IMBF) was assessed bilaterally within and between clinical sessions. The 133 Xe clearance in nine normal individuals was measured before, during, and immediately after endurance of isometric contraction at an attempted level of 50% of maximum voluntary clenching contraction. An overall low reproducibility of the estimations was found. This result was probably caused by uncertainties about the excact site of intramuscular 133 Xe deposition, errors in assessment of the plots of clearance, and variabilities in the relative contraction levels sustained, especially in the overall muscle effort. In agreement with previous reports concerning other skeletal muscles, the 133 Xe clearance method provided inconsistent estimates of absolute values of IMBF also in this clinical setting. Although there was a high intra-individual variation in the relative level of isometric contraction sustained, the endurance test induced distinct changes in IMBF, among which the estimate of post-endurance hyperemia was the most consistent for each individual. Therefore, measurements of 133 Xe clearance seem to be useful to detect intra-induvidual changes in masseter IMBF resulting from isometric work. 21 refs

  3. Search for electric dipole moment in 129Xe atom using active nuclear spin maser

    Directory of Open Access Journals (Sweden)

    Ichikawa Y.

    2014-03-01

    Full Text Available An experimental search for an electric dipole moment in the diamagnetic atom 129Xe is in progress through the precision measurement of spin precession frequency using an active nuclear spin maser. A 3He comagnetometer has been incorporated into the active spin maser system in order to cancel out the long-term drifts in the external magnetic field. Also, a double-cell geometry has been adopted in order to suppress the frequency shifts due to interaction with polarized Rb atoms. The first EDM measurement with the 129Xe active spin maser and the 3He comagnetometer has been conducted.

  4. Influence of Selected Parameters of XeCl Excimer Laser System on Characteristics of Radiation Pulses

    International Nuclear Information System (INIS)

    Pokora, L.; Iwanejko, L.

    1998-01-01

    We present the dependences of energy and duration of radiation pulses as well as efficiency of XeCl laser on selected parameters of the laser system such as: C 2 capacitance, the separating inductance, L S , the distance between electrodes in laser's chamber, d K and also the supply voltage, U 0 , composition, and pressure of the active-medium mixture of gases. Results of numerical computations relate to a three-component mixture of gases, He-Xe-HCl, of the active medium of the excimer laser. (author)

  5. Adsorption properties of fission gases Xe and Kr on pristine and doped graphene: A first principle DFT study

    Energy Technology Data Exchange (ETDEWEB)

    Vazhappilly, Tijo, E-mail: tijoj@barc.gov.in [Theoretical Chemistry Section, Chemistry Group, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Ghanty, Tapan K., E-mail: tapang@barc.gov.in [Theoretical Chemistry Section, Chemistry Group, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094 (India); Jagatap, B.N. [Theoretical Chemistry Section, Chemistry Group, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2017-07-15

    Graphene has excellent adsorption properties due to large surface area and has been used in applications related to gas sorption and separation. The separation of radioactive noble gases using graphene is an interesting area of research relevant to nuclear waste management. Radioactive noble gases Xe and Kr are present in the off-gas streams from nuclear fission reactors and spent nuclear fuel reprocessing plants. The entrapment of these volatile fission gases is important in the context of nuclear safety. The separation of Xe from Kr is extremely difficult, and energy intensive cryogenic distillation is generally employed. Physisorption based separation techniques using porous materials is a cost effective alternative to expensive cryogenic distillation. Thus, adsorption of noble gases on graphene is relevant for fundamental understanding of physisorption process. The properties of graphene can be tuned by doping and incorporation of defects. In this regard, we study the binding affinity of Xe and Kr in pristine and doped graphene sheets. We employ first principle calculations using density functional theory, corrected for dispersion interactions. The structural parameters obtained from the current study show excellent agreement with the available theoretical and experimental observations on similar systems. Noble gas adsorption energies on pristine graphene match very well with the available literature. Our results show that the binding energy of fission gases Xe and Kr on graphene can be considerably improved through doping the lattice with a heteroatom. - Graphical abstract: The adsorption of radioactive fission gases Xe and Kr on pristine/doped graphene is an interesting topic in the context of nuclear waste management. Previous experimental and computational studies about Xe/Kr adsorption on graphene were limited to only on pristine graphene. The doping by hetero atom changes the electronic properties of graphene and creates active sites in the lattice. Based

  6. Prediction of Effective Drug Combinations by Chemical Interaction, Protein Interaction and Target Enrichment of KEGG Pathways

    Directory of Open Access Journals (Sweden)

    Lei Chen

    2013-01-01

    Full Text Available Drug combinatorial therapy could be more effective in treating some complex diseases than single agents due to better efficacy and reduced side effects. Although some drug combinations are being used, their underlying molecular mechanisms are still poorly understood. Therefore, it is of great interest to deduce a novel drug combination by their molecular mechanisms in a robust and rigorous way. This paper attempts to predict effective drug combinations by a combined consideration of: (1 chemical interaction between drugs, (2 protein interactions between drugs’ targets, and (3 target enrichment of KEGG pathways. A benchmark dataset was constructed, consisting of 121 confirmed effective combinations and 605 random combinations. Each drug combination was represented by 465 features derived from the aforementioned three properties. Some feature selection techniques, including Minimum Redundancy Maximum Relevance and Incremental Feature Selection, were adopted to extract the key features. Random forest model was built with its performance evaluated by 5-fold cross-validation. As a result, 55 key features providing the best prediction result were selected. These important features may help to gain insights into the mechanisms of drug combinations, and the proposed prediction model could become a useful tool for screening possible drug combinations.

  7. Buckwheat-enriched wheat bread: National market placement possibilities

    Directory of Open Access Journals (Sweden)

    Sakač Marijana B.

    2015-01-01

    Full Text Available Quality parameters and the possibility of successful placement of buckwheat-enriched wheat bread on the national market are presented in this paper. Analysis of the market position of buckwheat-enriched wheat bread includes demands, offer and competition. Elements that affect the overall retail price of buckwheat-enriched wheat bread are given in details, along with SWOT analysis and marketing plan including target market, market supply and product marketing mix. According to all performed analyses it could be concluded that this product should be positioned on the national market, especially for people with special needs and requirements.

  8. 9 CFR 124.20 - Patent term extension calculation.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Patent term extension calculation. 124... OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS PATENT TERM RESTORATION Regulatory Review Period § 124.20 Patent term extension calculation. (a) As provided in 37 CFR 1...

  9. 38 CFR 59.124 - Inspections, audits, and reports.

    Science.gov (United States)

    2010-07-01

    ... reports. (a) A State will allow VA inspectors and auditors to conduct inspections and audits as necessary... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Inspections, audits, and reports. 59.124 Section 59.124 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS...

  10. 12 CFR 225.124 - Foreign bank holding companies.

    Science.gov (United States)

    2010-01-01

    ... SYSTEM BANK HOLDING COMPANIES AND CHANGE IN BANK CONTROL (REGULATION Y) Regulations Financial Holding Companies Interpretations § 225.124 Foreign bank holding companies. (a) Effective December 1, 1971, the... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Foreign bank holding companies. 225.124 Section...

  11. Multicurie, transportable, integrally shielded 123Xe → 123I generator and processing system for high-purity iodine-123 production

    International Nuclear Information System (INIS)

    Lagunas-Solar, M.C.; Thibeau, H.L.; Goodart, C.E.; Little, F.E.; Navarro, N.J.; Hartnett, D.E.

    1985-01-01

    An integrally shielded 123 Xe → 123 I generator system has been designed and tested under production conditions for its suitability as a multicurie handling device from which to produce radiopharmaceutical-quality high-purity no-carrier-added (NCA) 123 I. The 123 Xe → 123 I generator system is expected to provide an alternative to current techniques and to increase the availability and reliability of high-purity 123 I made via the 127 I(p,5n) 123 Xe → 123 I nuclear reaction. The generator system is based on the Crocker Nuclear Laboratory's continuous-flow production system which has been operating since 1974 for the multicurie production of 123 I. The generator system, which consists of an integrally shielded xenon trap and separate loading and processing apparatuses, is simple and reliable to operate, can be adapted to computerized control, and provides a safe working environment for the repeated handling of multicurie amounts of Xe-I radioactivities

  12. Regioselectivity in the Thermal Rearrangement of Unsymmetrical 4-Methyl-4H-1,2,4-triazoles to 1-Methyl-1H-1,2,4-triazoles

    Directory of Open Access Journals (Sweden)

    Per H.J. Carlsen

    2001-11-01

    Full Text Available The rearrangement of 4-methyl-3,5-diaryl-4H-1,2,4-triazoles to the corresponding 1-methyl-3,5-diaryl-1H-1,2,4-triazoles showed regioselectivity comparable to that observed for the alkylation of 3,5-diaryl-1H-1,2,4-triazoles. This lends support to a proposed mechanism for the rearrangement that involves consecutive nucleophilic displacements steps.

  13. Isotope Shifts and Hyperfine Structure in the[Xe]4f(7)5d 6s(2) D-2(J)->[Xe]4f(7)5d 6s 6p F-9(J+1) Transitions of Gadolinium

    International Nuclear Information System (INIS)

    Blaum, K.; Bushaw, Bruce A.; Diel, S; Geppert, Ch; Kuschnick, A; Muller, P.; Nortershauser, W.; Schmitt, A.; Wendt, K.

    1999-01-01

    High-resolution resonance ionization mass spectrometry has been used to measure isotope shifts and hyperfine structure in all[Xe] 4f 7 5d 6s2 9DJ ---[Xe] 4f 7 5d 6s 6p 9FJ+1 (J= 2-6) and the[Xe] 4f 7 5d 6s2 9D6---[Xe] 4f 7 5d 6s 6p 9D5 transitions of gadolinium (Gd I). Gadolinium atoms in an atomic beam were excited with a tunable single-frequency laser in the wavelength range of 422 - 429 nm. Resonant excitation was followed by photoionization with the 363.8 nm line of an argon ion laser and resulting ions were mass separated and detected with a quadrupole mass spectrometer. Isotope shifts for all stable gadolinium isotopes in these transitions have been measured for the first time. Additionally, the hyperfine structure constants of the upper states have been derived for the isotopes 155, 157Gd and are compared with previous work. Using prior experimental values for the mean nuclear charge radii, derived from the combination of muonic atoms and electron scattering data, field shift a nd specific mass shift coefficients for the investigated transitions have been determined and nuclear charge parameters l for the minor isotopes 152, 154Gd have been calculated

  14. Nondipole effects in the photoionization of Xe 4d: Evidence for quadrupole satellites

    International Nuclear Information System (INIS)

    Hemmers, O.; Guillemin, R.; Wolska, A.; Lindle, D.W.; Rolles, D.; Cheng, K.T.; Johnson, W.R.; Zhou, H.L.; Manson, S.T.

    2004-01-01

    Full text: We measured the nondipole parameters for the spin-orbit depletes Xe 4d 5/2 and Xe 4d 3/2 over a photonenergy range from 100 eV to 250 eV at beamline 8.0.1.3 of the Advanced Light Source at the Lawrence Berkeley National Laboratory. Significant nondipole effects are found at relatively low energies as a result of Cooper minima in dipole channels and interchannel coupling in quadrupole channels. Most importantly, sharp disagreement between experiment and theory, when otherwise excellent agreement was expected, has provided the first evidence of satellite two-electron quadrupole photoionization transitions, along with their crucial importance for a quantitatively accurate theory

  15. The production of radioisotopes for medical applications by the adiabatic resonance crossing (ARC) technique

    CERN Document Server

    Froment, P; Delbar, T; Ryckewaert, G; Tilquin, I; Vervier, J

    2002-01-01

    The Transmutation by Adiabatic Resonance Crossing (TARC) technique has been proposed by Rubbia (Resonance enhanced neutron captures for element activation and waste transmutation, CERN-LHC/97-0040EET, 1997; TARC collaboration, Neutron-driven nuclear transmutation by adiabatic resonance crossing, CERN-SL-99-036EET, 1999; Abanades et al., Nucl. Instr. and Meth. A 487 (2002) 577) for element activation and waste transmutation. We investigate the possibility to use this technique for the industrial production of **9**9Mo and **1**2**5Xe by resonance neutron capture in **9**8Mo and **1**2**4Xe, respectively. Their daughters, i.e. **9**9**mTc and **1**2**5I, are widely used in medical applications. The high neutron flux needed is produced by bombarding a thick Be target with 65 or 75 MeV proton beam (few microamperes). This target is placed at the centre of a large cubic lead assembly (1.6 m side, purity: 99.999%). The neutrons are progressively slowed down by elastic scattering on lead, and their energies "scan" t...

  16. 9 CFR 124.10 - APHIS liaison with PTO.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false APHIS liaison with PTO. 124.10 Section 124.10 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... period was the first permitted commercial marketing or use of the product under the provision of law...

  17. Confinement and correlation effects in the Xe-C{sub 60} generalized oscillator strengths

    Energy Technology Data Exchange (ETDEWEB)

    Amusia, M. Ya. [Racah Institute of Physics, Hebrew University, 91904 Jerusalem (Israel); A. F. Ioffe Physical-Technical Institute, 194021 St. Petersburg (Russian Federation); Chernysheva, L. V. [A. F. Ioffe Physical-Technical Institute, 194021 St. Petersburg (Russian Federation); Dolmatov, V. K. [Department of Physics and Earth Science, University of North Alabama, Florence, Alabama 35632 (United States)

    2011-12-15

    The impact of both confinement and electron correlation on generalized oscillator strengths (GOS's) of endohedral atoms, A-C{sub 60}, is theoretically studied choosing the Xe-C{sub 60} 4d, 5s, and 5p fast electron impact ionization as the case study. Calculations are performed in the transferred to the atom energy region beyond the 4d threshold, {omega}=75-175 eV. The calculation methodology combines the plane-wave Born approximation, Hartree-Fock approximation, and random-phase approximation with exchange in the presence of the C{sub 60} confinement. The confinement is modeled by a spherical {delta}-function-like potential as well as by a square well potential to evaluate the effect of the finite thickness of the C{sub 60} cage on the Xe-C{sub 60} GOS's. Dramatic distortion of the 4d, 5p, and 5s GOS's by the confinement is demonstrated, compared to the free atom. Considerable contributions of multipolar transitions beyond dipole transitions in the calculated GOS's are revealed, in some instances. The vitality of accounting for electron correlation in calculation of the Xe-C{sub 60} 5s and 5p GOS's is shown.

  18. Xerostomia Quality of Life Scale (XeQoLS) questionnaire: validation of Italian version in head and neck cancer patients.

    Science.gov (United States)

    Lastrucci, Luciana; Bertocci, Silvia; Bini, Vittorio; Borghesi, Simona; De Majo, Roberta; Rampini, Andrea; Gennari, Pietro Giovanni; Pernici, Paola

    2018-01-01

    To translate the Xerostomia Quality-of-Life Scale (XeQoLS) into Italian language (XeQoLS-IT). Xerostomia is the most relevant acute and late toxicity in patients with head and neck cancer treated with radiotherapy (RT). Patient-reported outcome (PRO) instruments are subjective report on patient perception of health status. The XeQoLS consists of 15 items and measures the impact of salivary gland dysfunction and xerostomia on the four major domains of oral health-related QoL. The XeQoLS-IT was created through a linguistic validation multi-step process: forward translation (TF), backward translation (TB) and administration of the questionnaire to 35 Italian patients with head and neck cancer. Translation was independently carried out by two radiation oncologists who were Italian native speakers. The two versions were compared and adapted to obtain a reconciled version, version 1 (V1). V1 was translated back into English by an Italian pro skilled in teaching English. After review of discrepancies and choice of the most appropriate wording for clarity and similarity to the original, version 2 (V2) was reached by consensus. To evaluate version 2, patients completed the XeQoLS-IT questionnaire and also underwent a cognitive debriefing. The questionnaire was considered simple by the patients. The clarity of the instructions and the easiness to answer questions had a mean value of 4.5 (± 0.71) on a scale from 1 to 5. A valid multi-step process led to the creation of the final version of the XeQoLS-IT, a suitable instrument for the perception of xerostomia in patients treated with RT.

  19. Theoretical modeling of yields for proton-induced reactions on natural and enriched molybdenum targets

    Energy Technology Data Exchange (ETDEWEB)

    Celler, A; Hou, X [University of British Columbia, Vancouver, BC, Canada, (Canada); Benard, F; Ruth, T, E-mail: aceller@physics.ubc.ca, E-mail: xinchi@phas.ubc.ca, E-mail: fbenard@bccrc.ca, E-mail: truth@triumf.ca [BC Cancer Agency, Vancouver, BC (Canada)

    2011-09-07

    Recent acute shortage of medical radioisotopes prompted investigations into alternative methods of production and the use of a cyclotron and {sup 100}Mo(p,2n){sup 99m}Tc reaction has been considered. In this context, the production yields of {sup 99m}Tc and various other radioactive and stable isotopes which will be created in the process have to be investigated, as these may affect the diagnostic outcome and radiation dosimetry in human studies. Reaction conditions (beam and target characteristics, and irradiation and cooling times) need to be optimized in order to maximize the amount of {sup 99m}Tc and minimize impurities. Although ultimately careful experimental verification of these conditions must be performed, theoretical calculations can provide the initial guidance allowing for extensive investigations at little cost. We report the results of theoretically determined reaction yields for {sup 99m}Tc and other radioactive isotopes created when natural and enriched molybdenum targets are irradiated by protons. The cross-section calculations were performed using a computer program EMPIRE for the proton energy range 6-30 MeV. A computer graphical user interface for automatic calculation of production yields taking into account various reaction channels leading to the same final product has been created. The proposed approach allows us to theoretically estimate the amount of {sup 99m}Tc and its ratio relative to {sup 99g}Tc and other radioisotopes which must be considered reaction contaminants, potentially contributing to additional patient dose in diagnostic studies.

  20. Theoretical modeling of yields for proton-induced reactions on natural and enriched molybdenum targets.

    Science.gov (United States)

    Celler, A; Hou, X; Bénard, F; Ruth, T

    2011-09-07

    Recent acute shortage of medical radioisotopes prompted investigations into alternative methods of production and the use of a cyclotron and ¹⁰⁰Mo(p,2n)(99m)Tc reaction has been considered. In this context, the production yields of (99m)Tc and various other radioactive and stable isotopes which will be created in the process have to be investigated, as these may affect the diagnostic outcome and radiation dosimetry in human studies. Reaction conditions (beam and target characteristics, and irradiation and cooling times) need to be optimized in order to maximize the amount of (99m)Tc and minimize impurities. Although ultimately careful experimental verification of these conditions must be performed, theoretical calculations can provide the initial guidance allowing for extensive investigations at little cost. We report the results of theoretically determined reaction yields for (99m)Tc and other radioactive isotopes created when natural and enriched molybdenum targets are irradiated by protons. The cross-section calculations were performed using a computer program EMPIRE for the proton energy range 6-30 MeV. A computer graphical user interface for automatic calculation of production yields taking into account various reaction channels leading to the same final product has been created. The proposed approach allows us to theoretically estimate the amount of (99m)Tc and its ratio relative to (99g)Tc and other radioisotopes which must be considered reaction contaminants, potentially contributing to additional patient dose in diagnostic studies.