WorldWideScience

Sample records for enhancement imaging standardised

  1. Standardisation of liver MDCT by tracking liver parenchyma enhancement to trigger imaging

    International Nuclear Information System (INIS)

    Brodoefel, H.; Tognolini, A.; Zamboni, G.A.; Gourtsoyianni, S.; Raptopoulos, V.; Claussen, C.D.

    2012-01-01

    To assess parenchymal bolus-triggering in terms of liver enhancement, lesion-to-liver conspicuity and inter-image variability across serial follow-up MDCTs. We reviewed MDCTs of 50 patients with hepatic metastases who had a baseline CT and two follow-up examinations. In 25 consecutive patients CT data acquisition was initiated by liver parenchyma triggering at a 50-HU enhancement threshold. In a matched control group, imaging was performed with an empirical delay of 65 s. CT attenuation values were assessed in vessels, liver parenchyma and metastasis. Target lesions were classified according to five enhancement patterns. Compared with the control group, liver enhancement was significantly higher with parenchyma triggering (59.8 ± 7.6 HU vs. 48.8 ± 11.2 HU, P = 0.0002). The same was true for conspicuity (liver parenchyma - lesion attenuation) of hypo-enhancing lesions (72.2 ± 15.9 HU vs. 52.7 ± 19.4 HU, P = 0.0006). Liver triggering was associated with reduced variability for liver enhancement among different patients (P = 0.035) and across serial follow-up examinations in individual patients (P < 0.0001). The number of patients presenting with uniform lesion enhancement pattern across serial examinations was significantly higher in the triggered group (20 vs. 11; P = 0.018). Liver parenchyma triggering provides superior lesion conspicuity and improves standardisation of image quality across follow-up examinations with greater uniformity of enhancement patterns. (orig.)

  2. EAU standardised medical terminology for urologic imaging: a taxonomic approach.

    Science.gov (United States)

    Loch, Tillmann; Carey, Brendan; Walz, Jochen; Fulgham, Pat Fox

    2015-05-01

    The terminology and abbreviations used in urologic imaging have generally been adopted on an ad hoc basis by different speciality groups; however, there is a need for shared nomenclature to facilitate clinical communication and collaborative research. This work reviews the current nomenclature for urologic imaging used in clinical practice and proposes a taxonomy and terminology for urologic imaging studies. A list of terms used in urologic imaging were compiled from guidelines published by the European Association of Urology and the American Urological Association and from the American College of Radiology Appropriateness Criteria. Terms searched were grouped into broad categories based on technology, and imaging terms were further stratified based on the anatomic extent, contrast or phases, technique or modifiers, and combinations or fusions. Terms that had a high degree of utilisation were classified as accepted. We propose a new taxonomy to define a more useful and acceptable nomenclature model acceptable to all health professionals involved in urology. The major advantage of a taxonomic approach to the classification of urologic imaging studies is that it provides a flexible framework for classifying the modifications of current imaging modalities and allows the incorporation of new imaging modalities. The adoption of this hierarchical classification model ranging from the most general to the most detailed descriptions should facilitate hierarchical searches of the medical literature using both general and specific terms. This work is limited in its scope, as it is not currently all-inclusive. This will hopefully be addressed by future modification as others embrace the concept and work towards uniformity in nomenclature. This paper provides a noncomprehensive list of the most widely used terms across different specialties. This list can be used as the basis for further discussion, development, and enhancement. In this paper we describe a classification system

  3. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    Science.gov (United States)

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  4. A review of imaging protocols for suspected skeletal dysplasia and a proposal for standardisation

    International Nuclear Information System (INIS)

    Watson, Sarah G.; Calder, Alistair D.; Offiah, Amaka C.; Negus, Samantha

    2015-01-01

    Expert radiology opinions are often requested to aid diagnosis of skeletal dysplasias or dysostoses, but due to variability in the imaging protocols used at different centres the views presented may be considered inadequate or incomplete resulting in diagnostic delays and increased patient and family anxiety. We propose the introduction of a standardised protocol that may be adapted in certain specific situations. (orig.)

  5. A review of imaging protocols for suspected skeletal dysplasia and a proposal for standardisation

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Sarah G. [Royal Surrey County Hospital, Department of Radiology, Surrey (United Kingdom); Calder, Alistair D. [Great Ormond Street Hospital for Children, NHS Foundation Trust, Department of Radiology, London (United Kingdom); Offiah, Amaka C. [Sheffield Children' s NHS Foundation Trust, The University of Sheffield Academic Unit of Child Health, Sheffield (United Kingdom); Negus, Samantha [St George' s Hospital, Department of Radiology, London (United Kingdom)

    2015-11-15

    Expert radiology opinions are often requested to aid diagnosis of skeletal dysplasias or dysostoses, but due to variability in the imaging protocols used at different centres the views presented may be considered inadequate or incomplete resulting in diagnostic delays and increased patient and family anxiety. We propose the introduction of a standardised protocol that may be adapted in certain specific situations. (orig.)

  6. A semantically rich and standardised approach enhancing discovery of sensor data and metadata

    Science.gov (United States)

    Kokkinaki, Alexandra; Buck, Justin; Darroch, Louise

    2016-04-01

    The marine environment plays an essential role in the earth's climate. To enhance the ability to monitor the health of this important system, innovative sensors are being produced and combined with state of the art sensor technology. As the number of sensors deployed is continually increasing,, it is a challenge for data users to find the data that meet their specific needs. Furthermore, users need to integrate diverse ocean datasets originating from the same or even different systems. Standards provide a solution to the above mentioned challenges. The Open Geospatial Consortium (OGC) has created Sensor Web Enablement (SWE) standards that enable different sensor networks to establish syntactic interoperability. When combined with widely accepted controlled vocabularies, they become semantically rich and semantic interoperability is achievable. In addition, Linked Data is the recommended best practice for exposing, sharing and connecting information on the Semantic Web using Uniform Resource Identifiers (URIs), Resource Description Framework (RDF) and RDF Query Language (SPARQL). As part of the EU-funded SenseOCEAN project, the British Oceanographic Data Centre (BODC) is working on the standardisation of sensor metadata enabling 'plug and play' sensor integration. Our approach combines standards, controlled vocabularies and persistent URIs to publish sensor descriptions, their data and associated metadata as 5 star Linked Data and OGC SWE (SensorML, Observations & Measurements) standard. Thus sensors become readily discoverable, accessible and useable via the web. Content and context based searching is also enabled since sensors descriptions are understood by machines. Additionally, sensor data can be combined with other sensor or Linked Data datasets to form knowledge. This presentation will describe the work done in BODC to achieve syntactic and semantic interoperability in the sensor domain. It will illustrate the reuse and extension of the Semantic Sensor

  7. Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

    International Nuclear Information System (INIS)

    Souvatzoglou, M.; Ziegler, S.I.; Martinez, M.J.; Dzewas, G.; Schwaiger, M.; Bengel, F.; Busch, R.

    2007-01-01

    In PET/CT, CT-derived attenuation factors may influence standardised uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET. Therefore, we compared PET/CT-derived SUVs intra-individually in various organs and tumour lesions with stand-alone PET-derived SUVs. Thirty-five patients with known or suspected cancer were prospectively included. Sixteen patients underwent FDG PET using an ECAT HR+scanner, and subsequently a second scan using a Biograph Sensation 16PET/CT scanner. Nineteen patients were scanned in the reverse order. All images were reconstructed with an iterative algorithm (OSEM). Suspected lesions were grouped as paradiaphragmatic versus distant from the diaphragm. Mean and maximum SUVs were also calculated for brain, lung, liver, spleen and vertebral bone. The attenuation coefficients (μ values) used for correction of emission data (bone, soft tissue, lung) in the two data sets were determined. A body phantom containing six hot spheres and one cold cylinder was measured using the same protocol as in patients. Forty-six lesions were identified. There was a significant correlation of maximum and mean SUVs derived from PET and PET/CT for 14 paradiaphragmatic lesions (r=0.97 respectively; p<0.001 respectively) and for 32 lesions located distant from the diaphragm (r=0.87 and r=0.89 respectively; p<0.001 respectively). No significant differences were observed in the SUVs calculated with PET and PET/CT in the lesions or in the organs. In the phantom, radioactivity concentration in spheres calculated from PET and from PET/CT correlated significantly (r=0.99; p<0.001). SUVs of cancer lesions and normal organs were comparable between PET and PET/CT, supporting the usefulness of PET/CT-derived SUVs for quantification of tumour metabolism. (orig.)

  8. Standardisation of the MRI image evaluation in the diagnostics of rheumatoid arthritis within the wrist and metacarpophalangeal joints

    International Nuclear Information System (INIS)

    Kapuscinska, K.; Urbanik, A.; Wojciechowski, W.

    2009-01-01

    Rheumatoid arthritis (RA) is a chronic systemic autoimmune disease of the connective tissue, which results in disability and earlier death. Thus it is very important to recognise this pathologic condition as early as possible, to lessen and delay its consequences. Currently, magnetic resonance imaging is the best imaging modality, depicting every stage of this disease and allowing for monitoring of the treatment response. The process of standardisation is needed in assessing MR pictures. The aim of this article was to present the MR protocols of hand and wrist MR examinations for rheumatologic demand and standards of results, according to worldwide OMERACT RAMRIS 2002 and supplemented by tenosynovitis system. (authors)

  9. Senior physiotherapy students as standardised patients for junior students enhances self-efficacy and satisfaction in both junior and senior students.

    Science.gov (United States)

    Mandrusiak, Allison M; Isles, Rosemary; Chang, Angela T; Choy, Nancy L Low; Toppenberg, Rowena; McCook, Donna; Smith, Michelle D; O'Leary, Karina; Brauer, Sandra G

    2014-05-23

    Standardised patients are used in medical education to expose students to clinical contexts and facilitate transition to clinical practice, and this approach is gaining momentum in physiotherapy programs. Expense and availability of trained standardised patients are factors limiting widespread adoption, and accessing clinical visits with real patients can be challenging. This study addressed these issues by engaging senior students as standardised patients for junior students. It evaluated how this approach impacted self-reported constructs of both the junior and senior students. Learning activities for undergraduate physiotherapy students were developed in five courses (Neurology, Cardiorespiratory and three Musculoskeletal courses) so that junior students (Year 2 and 3) could develop skills and confidence in patient interview, physical examination and patient management through their interaction with standardised patients played by senior students (Year 4). Surveys were administered before and after the interactions to record junior students' self-reported confidence, communication, preparedness for clinic, and insight into their abilities; and senior students' confidence and insight into what it is like to be a patient. Satisfaction regarding this learning approach was surveyed in both the junior and senior students. A total of 253 students completed the surveys (mean 92.5% response rate). Across all courses, junior students reported a significant (all P Senior students demonstrated a significant improvement in their confidence in providing feedback and insight into their own learning (P senior students as standardised patients resulted in positive experiences for both junior and senior students across a variety of physiotherapy areas, activities, and stages within a physiotherapy program. These findings support the engagement of senior students as standardised patients to enhance learning within physiotherapy programs, and may have application across other

  10. A standardised protocol for texture feature analysis of endoscopic images in gynaecological cancer

    Directory of Open Access Journals (Sweden)

    Pattichis Marios S

    2007-11-01

    Full Text Available Abstract Background In the development of tissue classification methods, classifiers rely on significant differences between texture features extracted from normal and abnormal regions. Yet, significant differences can arise due to variations in the image acquisition method. For endoscopic imaging of the endometrium, we propose a standardized image acquisition protocol to eliminate significant statistical differences due to variations in: (i the distance from the tissue (panoramic vs close up, (ii difference in viewing angles and (iii color correction. Methods We investigate texture feature variability for a variety of targets encountered in clinical endoscopy. All images were captured at clinically optimum illumination and focus using 720 × 576 pixels and 24 bits color for: (i a variety of testing targets from a color palette with a known color distribution, (ii different viewing angles, (iv two different distances from a calf endometrial and from a chicken cavity. Also, human images from the endometrium were captured and analysed. For texture feature analysis, three different sets were considered: (i Statistical Features (SF, (ii Spatial Gray Level Dependence Matrices (SGLDM, and (iii Gray Level Difference Statistics (GLDS. All images were gamma corrected and the extracted texture feature values were compared against the texture feature values extracted from the uncorrected images. Statistical tests were applied to compare images from different viewing conditions so as to determine any significant differences. Results For the proposed acquisition procedure, results indicate that there is no significant difference in texture features between the panoramic and close up views and between angles. For a calibrated target image, gamma correction provided an acquired image that was a significantly better approximation to the original target image. In turn, this implies that the texture features extracted from the corrected images provided for better

  11. Periorbital biometric measurements using ImageJ software: Standardisation of technique and assessment of intra- and interobserver variability

    Directory of Open Access Journals (Sweden)

    R Rajyalakshmi

    2017-01-01

    Full Text Available Purpose: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID serves as a reliable scale for facial measurements. Methods: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual’s HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the ‘average’ HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC and Pearson product-moment coefficient were used as statistical tests to analyse the data. Results: The range of ICC for intra- and interobserver variability was 0.79–0.99 and 0.86–0.99, respectively. Test-retest reliability ranged from 0.66–1.0 to 0.77–0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements. Conclusion: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements.

  12. Enhancement of blurred image portions

    NARCIS (Netherlands)

    2008-01-01

    This invention relates to a method for image enhancement, comprising a first step ( 41 ) of distinguishing blurred and non-blurred image portions of an input image, and a second step ( 42 ) of enhancing at least one of said blurred image portions of said input image to produce an output image. Said

  13. Proposal for the standardisation of multi-centre trials in nuclear medicine imaging

    DEFF Research Database (Denmark)

    Dickson, John Caddell; Tossici-Bolt, Livia; Sera, Terez

    2012-01-01

    Multi-centre trials are an important part of proving the efficacy of procedures, drugs and interventions. Imaging components in such trials are becoming increasingly common; however, without sufficient control measures the usefulness of these data can be compromised. This paper describes a framew...

  14. Evaluation of prognostic models developed using standardised image features from different PET automated segmentation methods.

    Science.gov (United States)

    Parkinson, Craig; Foley, Kieran; Whybra, Philip; Hills, Robert; Roberts, Ashley; Marshall, Chris; Staffurth, John; Spezi, Emiliano

    2018-04-11

    Prognosis in oesophageal cancer (OC) is poor. The 5-year overall survival (OS) rate is approximately 15%. Personalised medicine is hoped to increase the 5- and 10-year OS rates. Quantitative analysis of PET is gaining substantial interest in prognostic research but requires the accurate definition of the metabolic tumour volume. This study compares prognostic models developed in the same patient cohort using individual PET segmentation algorithms and assesses the impact on patient risk stratification. Consecutive patients (n = 427) with biopsy-proven OC were included in final analysis. All patients were staged with PET/CT between September 2010 and July 2016. Nine automatic PET segmentation methods were studied. All tumour contours were subjectively analysed for accuracy, and segmentation methods with segmentation methods studied, clustering means (KM2), general clustering means (GCM3), adaptive thresholding (AT) and watershed thresholding (WT) methods were included for analysis. Known clinical prognostic factors (age, treatment and staging) were significant in all of the developed prognostic models. AT and KM2 segmentation methods developed identical prognostic models. Patient risk stratification was dependent on the segmentation method used to develop the prognostic model with up to 73 patients (17.1%) changing risk stratification group. Prognostic models incorporating quantitative image features are dependent on the method used to delineate the primary tumour. This has a subsequent effect on risk stratification, with patients changing groups depending on the image segmentation method used.

  15. Repeatability, Reproducibility and Standardisation of a Laser Doppler Imaging Technique for the Evaluation of Normal Mouse Hindlimb Perfusion

    Directory of Open Access Journals (Sweden)

    Arturo Brunetti

    2012-12-01

    Full Text Available Background. Preclinical perfusion studies are useful for the improvement of diagnosis and therapy in dermatologic, cardiovascular and rheumatic human diseases. The Laser Doppler Perfusion Imaging (LDPI technique has been used to evaluate superficial alterations of the skin microcirculation in surgically induced murine hindlimb ischemia. We assessed the reproducibility and the accuracy of LDPI acquisitions and identified several critical factors that could affect LDPI measurements in mice. Methods. Twenty mice were analysed. Statistical standardisation and a repeatability and reproducibility analysis were performed on mouse perfusion signals with respect to differences in body temperature, the presence or absence of hair, the type of anaesthesia used for LDPI measurements and the position of the mouse body. Results. We found excellent correlations among measurements made by the same operator (i.e., repeatability under the same experimental conditions and by two different operators (i.e., reproducibility. A Bland-Altman analysis showed the absence of bias in repeatability (p = 0.29 or reproducibility (p = 0.89. The limits of agreement for repeatability were –0.357 and –0.033, and for reproducibility, they were –0.270 and 0.238. Significant differences in perfusion values were observed in different experimental groups. Conclusions. Different experimental conditions must be considered as a starting point for the evaluation of new drugs and strategic therapies.

  16. Novel medical image enhancement algorithms

    Science.gov (United States)

    Agaian, Sos; McClendon, Stephen A.

    2010-01-01

    In this paper, we present two novel medical image enhancement algorithms. The first, a global image enhancement algorithm, utilizes an alpha-trimmed mean filter as its backbone to sharpen images. The second algorithm uses a cascaded unsharp masking technique to separate the high frequency components of an image in order for them to be enhanced using a modified adaptive contrast enhancement algorithm. Experimental results from enhancing electron microscopy, radiological, CT scan and MRI scan images, using the MATLAB environment, are then compared to the original images as well as other enhancement methods, such as histogram equalization and two forms of adaptive contrast enhancement. An image processing scheme for electron microscopy images of Purkinje cells will also be implemented and utilized as a comparison tool to evaluate the performance of our algorithm.

  17. COMPARISON OF IMAGE ENHANCEMENT METHODS FOR CHROMOSOME KARYOTYPE IMAGE ENHANCEMENT

    Directory of Open Access Journals (Sweden)

    Dewa Made Sri Arsa

    2017-02-01

    Full Text Available The chromosome is a set of DNA structure that carry information about our life. The information can be obtained through Karyotyping. The process requires a clear image so the chromosome can be evaluate well. Preprocessing have to be done on chromosome images that is image enhancement. The process starts with image background removing. The image will be cleaned background color. The next step is image enhancement. This paper compares several methods for image enhancement. We evaluate some method in image enhancement like Histogram Equalization (HE, Contrast-limiting Adaptive Histogram Equalization (CLAHE, Histogram Equalization with 3D Block Matching (HE+BM3D, and basic image enhancement, unsharp masking. We examine and discuss the best method for enhancing chromosome image. Therefore, to evaluate the methods, the original image was manipulated by the addition of some noise and blur. Peak Signal-to-noise Ratio (PSNR and Structural Similarity Index (SSIM are used to examine method performance. The output of enhancement method will be compared with result of Professional software for karyotyping analysis named Ikaros MetasystemT M . Based on experimental results, HE+BM3D method gets a stable result on both scenario noised and blur image.

  18. Long range image enhancement

    CSIR Research Space (South Africa)

    Duvenhage, B

    2015-11-01

    Full Text Available the surveillance system performance. This paper discusses an image processing method that tracks the behaviour of the PSF and then de-warps the image to reduce the disruptive effects of turbulence. Optical flow, an average image filter and a simple unsharp mask...

  19. Retinex enhancement of infrared images.

    Science.gov (United States)

    Li, Ying; He, Renjie; Xu, Guizhi; Hou, Changzhi; Sun, Yunyan; Guo, Lei; Rao, Liyun; Yan, Weili

    2008-01-01

    With the ability of imaging the temperature distribution of body, infrared imaging is promising in diagnostication and prognostication of diseases. However the poor quality of the raw original infrared images prevented applications and one of the essential problems is the low contrast appearance of the imagined object. In this paper, the image enhancement technique based on the Retinex theory is studied, which is a process that automatically retrieve the visual realism to images. The algorithms, including Frackle-McCann algorithm, McCann99 algorithm, single-scale Retinex algorithm, multi-scale Retinex algorithm and multi-scale Retinex algorithm with color restoration, are experienced to the enhancement of infrared images. The entropy measurements along with the visual inspection were compared and results shown the algorithms based on Retinex theory have the ability in enhancing the infrared image. Out of the algorithms compared, MSRCR demonstrated the best performance.

  20. Image enhancement through deconvolution

    International Nuclear Information System (INIS)

    Zhang, Xiaodong; Jacobsen, C.; Williams, S.

    1993-01-01

    Several groups have been developing X-ray microscopes for studies of biological and materials specimens at suboptical resolution. The XIA Scanning Transmission X-ray Microscope at Brookhaven National Laboratory has achieved 55 nm Rayleigh resolution, and is limited by the 45 nm finest zone width of the zone plate used to focus the X-rays. In principle, features as small as half the outermost zone width, or 23 nm, can be observed in the microscope, though with reduced contrast in the image. One approach to recover the object from the image is to deconvolve the image with the Point Spread Function (PSF) of the optic system. Towards this end, the magnitude of the Fourier transform of the PSF, the Modulation Transfer Function, has been experimentally determined and agrees reasonably well with the calculations using the known parameters of the microscope. To minimize artifacts in the deconvolved images, large signal-to-noise ratios are required in the original image, and high frequency filters can be used to reduce the noise at the expense of resolution. In this way the authors are able to recover the original contrast of high resolution features in the images

  1. Standardised approach to optimisation

    International Nuclear Information System (INIS)

    Warren-Forward, Helen M.; Beckhaus, Ronald

    2004-01-01

    Optimisation of radiographic images is said to have been obtained if the patient has achieved an acceptable level of dose and the image is of diagnostic value. In the near future, it will probably be recommended that radiographers measure patient doses and compare them to reference levels. The aim of this paper is to describe a standardised approach to optimisation of radiographic examinations in a diagnostic imaging department. A three-step approach is outlined with specific examples for some common examinations (chest, abdomen, pelvis and lumbar spine series). Step One: Patient doses are calculated. Step Two: Doses are compared to existing reference levels and the technique used compared to image quality criteria. Step Three: Appropriate action is taken if doses are above the reference level. Results: Average entrance surface doses for two rooms were as follows AP Abdomen (6.3mGy and 3.4mGy); AP Lumbar Spine (6.4mGy and 4.1mGy) for AP Pelvis (4.8mGy and 2.6mGy) and PA chest (0.19mGy and 0.20mGy). Comparison with the Commission of the European Communities (CEC) recommended techniques identified large differences in the applied potential. The kVp values in this study were significantly lower (by up to lOkVp) than the CEC recommendations. The results of this study have indicated that there is a need to monitor radiation doses received by patients undergoing diagnostic radiography examinations. Not only has the assessment allowed valuable comparison with International Diagnostic Reference Levels and Radiography Good Practice but has demonstrated large variations in mean doses being delivered from different rooms of the same radiology department. Following the simple 3-step approach advocated in this paper should either provide evidence that department are practising the ALARA principle or assist in making suitable changes to current practice. Copyright (2004) Australian Institute of Radiography

  2. Stochastic Capsule Endoscopy Image Enhancement

    Directory of Open Access Journals (Sweden)

    Ahmed Mohammed

    2018-06-01

    Full Text Available Capsule endoscopy, which uses a wireless camera to take images of the digestive tract, is emerging as an alternative to traditional colonoscopy. The diagnostic values of these images depend on the quality of revealed underlying tissue surfaces. In this paper, we consider the problem of enhancing the visibility of detail and shadowed tissue surfaces for capsule endoscopy images. Using concentric circles at each pixel for random walks combined with stochastic sampling, the proposed method enhances the details of vessel and tissue surfaces. The framework decomposes the image into two detailed layers that contain shadowed tissue surfaces and detail features. The target pixel value is recalculated for the smooth layer using similarity of the target pixel to neighboring pixels by weighting against the total gradient variation and intensity differences. In order to evaluate the diagnostic image quality of the proposed method, we used clinical subjective evaluation with a rank order on selected KID image database and compared it to state-of-the-art enhancement methods. The result showed that the proposed method provides a better result in terms of diagnostic image quality and objective quality contrast metrics and structural similarity index.

  3. The need for standardisation of cardiac FDG PET imaging in the evaluation of myocardial viability in patients with chronic ischaemic left ventricular dysfunction

    International Nuclear Information System (INIS)

    Kuuti, J.; Schelbert, H.R.; Bax, J.J.

    2002-01-01

    The evaluation of myocardial glucose utilisation with fluorine-18 fluorodeoxyglucose (FDG) and positron emission tomography is currently considered the most reliable tool for the identification of myocardial viability. However, the investigations using FDG imaging to predict improvement in left ventricular (LV) function after revascularisation have reported wide ranges for sensitivity (71%-100%) and, in particular, for specificity (33%-91%). The variable results may be related to differences in study populations but also to differences in the imaging protocols employed. Detailed analysis of the published studies has revealed differences in study populations, patient selection criteria, the methods for assessing changes in LV function post revascularisation and the timing of these assessments. Even more importantly, protocols have varied substantially with regard to imaging equipment, perfusion tracers, metabolic conditions, data analysis and interpretation of results. In addition, evaluation of patients with insulin resistance appears to represent a specific challenge. This review examines the different study protocols and methodologies used for myocardial FDG imaging in order to draw conclusions concerning optimal imaging protocols. It appears that the optimisation and standardisation of study protocols and analysis of FDG images for the assessment of myocardial viability are critical. In addition, multi-centre trials seem warranted on prediction of long-term function, congestive heart failure symptoms, survival and quality of life

  4. Image analysis enhancement and interpretation

    International Nuclear Information System (INIS)

    Glauert, A.M.

    1978-01-01

    The necessary practical and mathematical background are provided for the analysis of an electron microscope image in order to extract the maximum amount of structural information. Instrumental methods of image enhancement are described, including the use of the energy-selecting electron microscope and the scanning transmission electron microscope. The problems of image interpretation are considered with particular reference to the limitations imposed by radiation damage and specimen thickness. A brief survey is given of the methods for producing a three-dimensional structure from a series of two-dimensional projections, although emphasis is really given on the analysis, processing and interpretation of the two-dimensional projection of a structure. (Auth.)

  5. Quantifying the effects of iodine contrast media on standardised uptake values of FDG PET/CT images: an anthropomorphic phantom study.

    Science.gov (United States)

    Abdul Razak, Hairil Rashmizal; Nordin, Abdul Jalil; Ackerly, Trevor; Van Every, Bruce; Martin, Ruth; Geso, Moshi

    2011-09-01

    This study aimed to quantify the amount of change in Standardised Uptake Values (SUVs) of PET/CT images by simulating the set-up as closely as possible to the actual patient scanning. The experiments were conducted using an anthropomorphic phantom, which contained an amount of radioactivity in the form of Fluorodeoxyglucose (FDG) in a primary plastic test tube and one litre saline bags, including the insertion of bony structures and another two test tubes containing different concentrations of iodine contrast media. Standard scanning protocols were employed for the PET/CT image acquisition. The highest absolute differences in the SUVmax and SUVmean values of the saline bags were found to be about 0.2 and 0.4, respectively. The primary test tube showed the largest change of 1.5 in both SUVs; SUV max and SUVmean. However, none of these changes were found to be statistically significant. The clinical literature also contains no evidence to suggest that the changes of this magnitude would change the final diagnosis. Based on these preliminary data, we propose that iodine contrast media can be used during the CT scan of PET/CT imaging, without significantly affecting the diagnostic quality of this integrated imaging modality.

  6. Standardising Software Processes - An Obstacle for Innovation?

    DEFF Research Database (Denmark)

    Aaen, Ivan; Pries-Heje, Jan

    2004-01-01

    Over the last 10 years CMM has achieved widespread use as a model for improving software organisations. Often CMM is used to standardise software processes across projects. In this paper we discuss this standardisation of SPI in relation to innovation, organisational size and company growth. Our...... discussion is empirically based on years work and experience working with companies on SPI. In the concrete our discussion is enhanced by vignette stories taken from our experience. As a result we find that standardisation focussing on process, metrics, and controls may jeopardize innovative capabilities...

  7. Use of count-based image reconstruction to evaluate the variability and repeatability of measured standardised uptake values.

    Directory of Open Access Journals (Sweden)

    Tomohiro Kaneta

    Full Text Available Standardized uptake values (SUVs are the most widely used quantitative imaging biomarkers in PET. It is important to evaluate the variability and repeatability of measured SUVs. Phantom studies seem to be essential for this purpose; however, repetitive phantom scanning is not recommended due to the decay of radioactivity. In this study, we performed count-based image reconstruction to avoid the influence of decay using two different PET/CT scanners. By adjusting the ratio of 18F-fluorodeoxyglucose solution to tap water, a NEMA IEC body phantom was set for SUVs of 4.0 inside six hot spheres. The PET data were obtained using two scanners (Aquiduo and Celesteion; Toshiba Medical Systems, Tochigi, Japan. We set the start time for image reconstruction when the total radioactivity in the phantom was 2.53 kBq/cc, and employed the counts of the first 2-min acquisition as the standard. To maintain the number of counts for each image, we set the acquisition time for image reconstruction depending on the decay of radioactivity. We obtained 50 images, and calculated the SUVmax and SUVpeak of all six spheres in each image. The average values of the SUVmax were used to calculate the recovery coefficients to compare those measured by the two different scanners. Bland-Altman analyses of the SUVs measured by the two scanners were also performed. The measured SUVs using the two scanners exhibited a 10-30% difference, and the standard deviation (SD of the measured SUVs was between 0.1-0.2. The Celesteion always exhibited higher values than the Aquiduo. The smaller sphere exhibited a larger SD, and the SUVpeak had a smaller SD than the SUVmax. The Bland-Altman analyses showed poor agreement between the SUVs measured by the two scanners. The recovery coefficient curves obtained from the two scanners were considerably different. The Celesteion exhibited higher recovery coefficients than the Aquiduo, especially at approximately 20-mm-diameter. Additionally, the curves

  8. Flemish Sign Language Standardisation

    Science.gov (United States)

    Van Herreweghe, Mieke; Vermeerbergen, Myriam

    2009-01-01

    In 1997, the Flemish Deaf community officially rejected standardisation of Flemish Sign Language. It was a bold choice, which at the time was not in line with some of the decisions taken in the neighbouring countries. In this article, we shall discuss the choices the Flemish Deaf community has made in this respect and explore why the Flemish Deaf…

  9. Infrared image enhancement with learned features

    Science.gov (United States)

    Fan, Zunlin; Bi, Duyan; Ding, Wenshan

    2017-11-01

    Due to the variation of imaging environment and limitations of infrared imaging sensors, infrared images usually have some drawbacks: low contrast, few details and indistinct edges. Hence, to promote the applications of infrared imaging technology, it is essential to improve the qualities of infrared images. To enhance image details and edges adaptively, we propose an infrared image enhancement method under the proposed image enhancement scheme. On the one hand, on the assumption of high-quality image taking more evident structure singularities than low-quality images, we propose an image enhancement scheme that depends on the extractions of structure features. On the other hand, different from the current image enhancement algorithms based on deep learning networks that try to train and build the end-to-end mappings on improving image quality, we analyze the significance of first layer in Stacked Sparse Denoising Auto-encoder and propose a novel feature extraction for the proposed image enhancement scheme. Experiment results prove that the novel feature extraction is free from some artifacts on the edges such as blocking artifacts, ;gradient reversal;, and pseudo contours. Compared with other enhancement methods, the proposed method achieves the best performance in infrared image enhancement.

  10. Gabor filter based fingerprint image enhancement

    Science.gov (United States)

    Wang, Jin-Xiang

    2013-03-01

    Fingerprint recognition technology has become the most reliable biometric technology due to its uniqueness and invariance, which has been most convenient and most reliable technique for personal authentication. The development of Automated Fingerprint Identification System is an urgent need for modern information security. Meanwhile, fingerprint preprocessing algorithm of fingerprint recognition technology has played an important part in Automatic Fingerprint Identification System. This article introduces the general steps in the fingerprint recognition technology, namely the image input, preprocessing, feature recognition, and fingerprint image enhancement. As the key to fingerprint identification technology, fingerprint image enhancement affects the accuracy of the system. It focuses on the characteristics of the fingerprint image, Gabor filters algorithm for fingerprint image enhancement, the theoretical basis of Gabor filters, and demonstration of the filter. The enhancement algorithm for fingerprint image is in the windows XP platform with matlab.65 as a development tool for the demonstration. The result shows that the Gabor filter is effective in fingerprint image enhancement technology.

  11. Enhancement of colposcopic image by sulphosalicylic acid.

    Directory of Open Access Journals (Sweden)

    Khilnani P

    1993-01-01

    Full Text Available Acetic acid is used conventionally for enhancement of the colposcopic image. We used sulphosalicylic acid instead of acetic acid in 50 normal cases. The normal appearance was enhanced in all cases. The image was also enhanced in 70% cases of cervical intraepithelial neoplasia and 90% cases of cervical condyloma accuminata. The image was not inferior to that with acetic acid in any of the cases.

  12. New Standardisation Fora and their Relationships with Traditional Standardisation Organisations

    DEFF Research Database (Denmark)

    Øst, Alexander G.

    The paper sets off by defining the fundamental concept of standards and proceeds by describing generic forms of standards (de facto and de jure) and various ways for standards to emerge. Then, the generic players (government, users, companies etc.) involved in the standardisation processes......, a synthesis of the identified development and standardisation trends of the converging landscape is made, providing a basis for prediction of future standardisation regimes....

  13. Overhauser-enhanced MR imaging (OMRI)

    DEFF Research Database (Denmark)

    Golman, K; Leunbach, I; Ardenkjaer-Larsen, JH

    1998-01-01

    Purpose. To evaluate a new single-electron contrast agent for Overhauser-enhanced MR imaging. The contrast agents that are currently available give enhancement factors that are too low to make the technique a valid option for routine clinical use. Material and Methods. MR images were generated di...

  14. Current standardisation for nanotechnology

    International Nuclear Information System (INIS)

    Bard, Delphine; Mark, David; Moehlmann, Carsten

    2009-01-01

    Standardisation and standards provide an important mechanism to support both innovation and the application of regulations. There is currently no specific regulation for any nanomaterials. Health, safety and environmental protection aspects associated with nanomaterials are however in principle covered to different levels by current EU regulatory framework. There are a number of national, European and international organisations developing standards associated with the development, description and use of nanomaterials as well as the protection of human health and the environment from the production and use of chemicals and consumer products, including nanomaterials. These organisations have also established specific committees on nanotechnology. This paper outlines the different relevant regulations and standards. This paper will mainly be focused on a European health and safety perspective.

  15. Automated image enhancement using power law transformations

    Indian Academy of Sciences (India)

    We propose a scheme for automating power law transformations which are used for image enhancement. The scheme we propose does not require the user to choose the exponent in the power law transformation. This method works well for images having poor contrast, especially to those images in which the peaks ...

  16. Dictionary-enhanced imaging cytometry

    Science.gov (United States)

    Orth, Antony; Schaak, Diane; Schonbrun, Ethan

    2017-02-01

    State-of-the-art high-throughput microscopes are now capable of recording image data at a phenomenal rate, imaging entire microscope slides in minutes. In this paper we investigate how a large image set can be used to perform automated cell classification and denoising. To this end, we acquire an image library consisting of over one quarter-million white blood cell (WBC) nuclei together with CD15/CD16 protein expression for each cell. We show that the WBC nucleus images alone can be used to replicate CD expression-based gating, even in the presence of significant imaging noise. We also demonstrate that accurate estimates of white blood cell images can be recovered from extremely noisy images by comparing with a reference dictionary. This has implications for dose-limited imaging when samples belong to a highly restricted class such as a well-studied cell type. Furthermore, large image libraries may endow microscopes with capabilities beyond their hardware specifications in terms of sensitivity and resolution. We call for researchers to crowd source large image libraries of common cell lines to explore this possibility.

  17. The logic of Technical Standardisation

    DEFF Research Database (Denmark)

    Nedergaard, Peter

    In this paper technical standardisation is understood and explained in a model where economic analysis is coupled with an analysis of the political system as proposed in rational choice theory. The aim is to answer both the question why various countries (e.g. the United States versus European...... countries) let either the market or public intervention determine the mode of technical standardisation and the possible implications of these two ways of organizing technical standardisation from an economic and a political point of view. Based upon the analysis of the paper a couple of general policy...... recommendations are made concerning the mode of technical standardisation....

  18. Diffraction enhanced x-ray imaging

    International Nuclear Information System (INIS)

    Thomlinson, W.; Zhong, Z.; Johnston, R.E.; Sayers, D.

    1997-09-01

    Diffraction enhanced imaging (DEI) is a new x-ray radiographic imaging modality using synchrotron x-rays which produces images of thick absorbing objects that are almost completely free of scatter. They show dramatically improved contrast over standard imaging applied to the same phantoms. The contrast is based not only on attenuation but also the refraction and diffraction properties of the sample. The diffraction component and the apparent absorption component (absorption plus extinction contrast) can each be determined independently. This imaging method may improve the image quality for medical applications such as mammography

  19. An enhanced fractal image denoising algorithm

    International Nuclear Information System (INIS)

    Lu Jian; Ye Zhongxing; Zou Yuru; Ye Ruisong

    2008-01-01

    In recent years, there has been a significant development in image denoising using fractal-based method. This paper presents an enhanced fractal predictive denoising algorithm for denoising the images corrupted by an additive white Gaussian noise (AWGN) by using quadratic gray-level function. Meanwhile, a quantization method for the fractal gray-level coefficients of the quadratic function is proposed to strictly guarantee the contractivity requirement of the enhanced fractal coding, and in terms of the quality of the fractal representation measured by PSNR, the enhanced fractal image coding using quadratic gray-level function generally performs better than the standard fractal coding using linear gray-level function. Based on this enhanced fractal coding, the enhanced fractal image denoising is implemented by estimating the fractal gray-level coefficients of the quadratic function of the noiseless image from its noisy observation. Experimental results show that, compared with other standard fractal-based image denoising schemes using linear gray-level function, the enhanced fractal denoising algorithm can improve the quality of the restored image efficiently

  20. Diffraction enhanced imaging: a simple model

    International Nuclear Information System (INIS)

    Zhu Peiping; Yuan Qingxi; Huang Wanxia; Wang Junyue; Shu Hang; Chen Bo; Liu Yijin; Li Enrong; Wu Ziyu

    2006-01-01

    Based on pinhole imaging and conventional x-ray projection imaging, a more general DEI (diffraction enhanced imaging) equation is derived using simple concepts in this paper. Not only can the new DEI equation explain all the same problems as with the DEI equation proposed by Chapman, but also some problems that cannot be explained with the old DEI equation, such as the noise background caused by small angle scattering diffracted by the analyser

  1. Diffraction enhanced imaging: a simple model

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Peiping; Yuan Qingxi; Huang Wanxia; Wang Junyue; Shu Hang; Chen Bo; Liu Yijin; Li Enrong; Wu Ziyu [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2006-10-07

    Based on pinhole imaging and conventional x-ray projection imaging, a more general DEI (diffraction enhanced imaging) equation is derived using simple concepts in this paper. Not only can the new DEI equation explain all the same problems as with the DEI equation proposed by Chapman, but also some problems that cannot be explained with the old DEI equation, such as the noise background caused by small angle scattering diffracted by the analyser.

  2. Multiple Image Radiography With Diffraction Enhanced Imaging For Breast Specimen

    International Nuclear Information System (INIS)

    Oltulu, Oral; Zhong Zhong; Hasnah, Moumen; Chapman, Dean

    2007-01-01

    Biological samples are of great interest for many imaging techniques. The samples usually contain small structures and weak absorption properties. The combinations of weak signals with overlying structures make feature recognition difficult in many cases. In the x-ray regime, a relatively new imaging technique Diffraction Enhanced Imaging (DEI) has superior tissue contrast over conventional radiography and is proven to be very sensitive method. Multiple images taken by DEI are called Multiple Image Radiography (MIR). The purpose of this study is to validate the potential application of the method and to show that MIR-DEI method may give more information about the sample

  3. Gd-DTPA-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Frank, J.A.; Choyke, P.L.; Carvlin, M.; Inscoe, S.; Austin, H.; Dwyer, A.J.; Girton, M.; Black, J.

    1988-01-01

    This paper describes dynamic enhanced renal MR imaging, a new method of identifying specific derangements in renal function. Various diuretics were employed in 45 animal experiments to demonstrate the effects on the normal renal enhancement pattern (EP) after Gd-DTPA. Since different diuretics, osmotic (O), carbonic anhydrase (CA), and loop (L), are active at different sites, specific EP alterations are observed. Imaging was performed with 32 5.1-second sequential gradient recalled acquisition in a steady state images following a bolus of Gd-DTPA

  4. Tooling Techniques Enhance Medical Imaging

    Science.gov (United States)

    2012-01-01

    They can release as much energy as tens of billions of hydrogen bombs exploding at the same time. They send protons and electrons rocketing at near the speed of light. They heat gas in the Sun s atmosphere to tens of millions of degrees Celsius. They send a blast of gas and particles toward Earth, posing a danger to spacecraft and astronauts outside the planet s magnetosphere, in rare cases even knocking out radio communications and power grids on the ground. They are so-called solar eruptive events, made up of solar flares and the often associated coronal mass ejections. Because of the scientific mystery of how these solar eruptions are produced on the Sun with such scale and force, and also the major role they play in space weather that can impact life on Earth, NASA researchers have innovated new methods of gathering information about these violent events. One NASA mission, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) has significantly advanced understanding of solar flares since its launch in 2002. RHESSI scientists use the spacecraft s imaging spectrometer to piece together pictures of solar flares from the high-energy X-ray and gamma-ray radiation they emit. While there is still much to be learned, data gathered by RHESSI has revealed how magnetic fields in the vast expanse of the solar atmosphere may be the force that drives the immense explosions. The instrument has imaged around 50,000 flares to date, providing information that may explain not only the workings of solar flares but also of much more massive energy releases from distant objects like black holes and quasars. We have been able to make images from X-rays with much finer resolution and greater sensitivity than have ever been made before, says Brian Dennis, RHESSI Mission Scientist and astrophysicist in the Solar Physics Laboratory at Goddard Space Flight Center. The key to RHESSI s unprecedented capabilities lie in a set of essential components a NASA partner created for the

  5. Multispectral image enhancement processing for microsat-borne imager

    Science.gov (United States)

    Sun, Jianying; Tan, Zheng; Lv, Qunbo; Pei, Linlin

    2017-10-01

    With the rapid development of remote sensing imaging technology, the micro satellite, one kind of tiny spacecraft, appears during the past few years. A good many studies contribute to dwarfing satellites for imaging purpose. Generally speaking, micro satellites weigh less than 100 kilograms, even less than 50 kilograms, which are slightly larger or smaller than the common miniature refrigerators. However, the optical system design is hard to be perfect due to the satellite room and weight limitation. In most cases, the unprocessed data captured by the imager on the microsatellite cannot meet the application need. Spatial resolution is the key problem. As for remote sensing applications, the higher spatial resolution of images we gain, the wider fields we can apply them. Consequently, how to utilize super resolution (SR) and image fusion to enhance the quality of imagery deserves studying. Our team, the Key Laboratory of Computational Optical Imaging Technology, Academy Opto-Electronics, is devoted to designing high-performance microsat-borne imagers and high-efficiency image processing algorithms. This paper addresses a multispectral image enhancement framework for space-borne imagery, jointing the pan-sharpening and super resolution techniques to deal with the spatial resolution shortcoming of microsatellites. We test the remote sensing images acquired by CX6-02 satellite and give the SR performance. The experiments illustrate the proposed approach provides high-quality images.

  6. Enhancement of image contrast in linacgram through image processing

    International Nuclear Information System (INIS)

    Suh, Hyun Suk; Shin, Hyun Kyo; Lee, Re Na

    2000-01-01

    Conventional radiation therapy portal images gives low contrast images. The purpose of this study was to enhance image contrast of a linacgram by developing a low--cost image processing method. Chest linacgram was obtained by irradiating humanoid phantom and scanned using Diagnostic-Pro scanner for image processing. Several types of scan method were used in scanning. These include optical density scan, histogram equalized scan, linear histogram based scan, linear histogram independent scan, linear optical density scan, logarithmic scan, and power square root scan. The histogram distribution of the scanned images were plotted and the ranges of the gray scale were compared among various scan types. The scanned images were then transformed to the gray window by pallette fitting method and the contrast of the reprocessed portal images were evaluated for image improvement. Portal images of patients were also taken at various anatomic sites and the images were processed by Gray Scale Expansion (GSE) method. The patient images were analyzed to examine the feasibility of using the GSE technique in clinic. The histogram distribution showed that minimum and maximum gray scale ranges of 3192 and 21940 were obtained when the image was scanned using logarithmic method and square root method, respectively. Out of 256 gray scale, only 7 to 30% of the steps were used. After expanding the gray scale to full range, contrast of the portal images were improved. Experiment performed with patient image showed that improved identification of organs were achieved by GSE in portal images of knee joint, head and neck, lung, and pelvis. Phantom study demonstrated that the GSE technique improved image contrast of a linacgram. This indicates that the decrease in image quality resulting from the dual exposure, could be improved by expanding the gray scale. As a result, the improved technique will make it possible to compare the digitally reconstructed radiographs (DRR) and simulation image for

  7. Compositional images from the Diffraction Enhanced Imaging technique

    International Nuclear Information System (INIS)

    Hasnah, M.O.; Zhong, Z.; Parham, C.; Zhang, H.; Chapman, D.

    2007-01-01

    Diffraction Enhanced Imaging (DEI) derives X-ray contrast from absorption, refraction, and extinction. While the refraction angle image of DEI represents the gradient of the projected mass density of the object, the absorption image measures the projected attenuation (μt)-bar of an object. Using a simple integral method it has been shown that a mass density image (ρt)-bar can be obtained from the refraction angle image. It then is a simple matter to develop a combinational image by dividing these two images to create a μ/ρ image. The μ/ρ is a fundamental property of a material and is therefore useful for identifying the composition of an object. In projection X-ray imaging the μ/ρ image identifies the integrated composition of the elements along the beam path. When applied to DEI computed tomography (CT), the image identifies the composition in each voxel. This method presents a new type of spectroscopy based in radiography. We present the method of obtaining the compositional image, the results of experiments in which we verify the method with known standards and an application of the method to breast cancer imaging

  8. Overhauser-enhanced MR imaging (OMRI)

    International Nuclear Information System (INIS)

    Golman, K.; Leunbach, I.; Ardenkjaer-Larsen, J.H.; Wistrand, L.G.; Petersson, J.S.; Ehnholm, G.J.; Jaervi, A.; Vahasalo, S.

    1998-01-01

    Purpose: To evaluate a new single-electron contrast agent for Overhauser-enhanced MR imaging. The contrast agents that are currently available give enhancement factors that are too low to make the technique a valid option for routine clinical use. Material and Methods: MR images were generated directly following the injection of the substance into rats. The MR scanner was operated at a main magnetic field of 0.01 T and equipped with a separate rf-transmitter tuned to the electron paramagnetic resonance frequency of the contrast agent. Results: As expected, the images generated show a high level of enhancement in areas where the contrast agent was present, and a maximum enhancement of 60 times the normal proton signal was obtained in the vascular area. The signal-to-noise ratios in the images were superior to those previously attained. Conclusion: The new contrast agent makes it possible to generate MR images with both morphological and functional information at 0.01 T. The signal-to-noise ratios found in the generated images were of the same order as, or better than, those obtained with the standard clinical routine. (orig.)

  9. Contrast enhancement of mail piece images

    Science.gov (United States)

    Shin, Yong-Chul; Sridhar, Ramalingam; Demjanenko, Victor; Palumbo, Paul W.; Hull, Jonathan J.

    1992-08-01

    A New approach to contrast enhancement of mail piece images is presented. The contrast enhancement is used as a preprocessing step in the real-time address block location (RT-ABL) system. The RT-ABL system processes a stream of mail piece images and locates destination address blocks. Most of the mail pieces (classified into letters) show high contrast between background and foreground. As an extreme case, however, the seasonal greeting cards usually use colored envelopes which results in reduced contrast osured by an error rate by using a linear distributed associative memory (DAM). The DAM is trained to recognize the spectra of three classes of images: with high, medium, and low OCR error rates. The DAM is not forced to make a classification every time. It is allowed to reject as unknown a spectrum presented that does not closely resemble any that has been stored in the DAM. The DAM was fairly accurate with noisy images but conservative (i.e., rejected several text images as unknowns) when there was little ground and foreground degradations without affecting the nondegraded images. This approach provides local enhancement which adapts to local features. In order to simplify the computation of A and (sigma) , dynamic programming technique is used. Implementation details, performance, and the results on test images are presented in this paper.

  10. Enhancing forensic science with spectroscopic imaging

    Science.gov (United States)

    Ricci, Camilla; Kazarian, Sergei G.

    2006-09-01

    This presentation outlines the research we are developing in the area of Fourier Transform Infrared (FTIR) spectroscopic imaging with the focus on materials of forensic interest. FTIR spectroscopic imaging has recently emerged as a powerful tool for characterisation of heterogeneous materials. FTIR imaging relies on the ability of the military-developed infrared array detector to simultaneously measure spectra from thousands of different locations in a sample. Recently developed application of FTIR imaging using an ATR (Attenuated Total Reflection) mode has demonstrated the ability of this method to achieve spatial resolution beyond the diffraction limit of infrared light in air. Chemical visualisation with enhanced spatial resolution in micro-ATR mode broadens the range of materials studied with FTIR imaging with applications to pharmaceutical formulations or biological samples. Macro-ATR imaging has also been developed for chemical imaging analysis of large surface area samples and was applied to analyse the surface of human skin (e.g. finger), counterfeit tablets, textile materials (clothing), etc. This approach demonstrated the ability of this imaging method to detect trace materials attached to the surface of the skin. This may also prove as a valuable tool in detection of traces of explosives left or trapped on the surfaces of different materials. This FTIR imaging method is substantially superior to many of the other imaging methods due to inherent chemical specificity of infrared spectroscopy and fast acquisition times of this technique. Our preliminary data demonstrated that this methodology will provide the means to non-destructive detection method that could relate evidence to its source. This will be important in a wider crime prevention programme. In summary, intrinsic chemical specificity and enhanced visualising capability of FTIR spectroscopic imaging open a window of opportunities for counter-terrorism and crime-fighting, with applications ranging

  11. Detail Enhancement for Infrared Images Based on Propagated Image Filter

    Directory of Open Access Journals (Sweden)

    Yishu Peng

    2016-01-01

    Full Text Available For displaying high-dynamic-range images acquired by thermal camera systems, 14-bit raw infrared data should map into 8-bit gray values. This paper presents a new method for detail enhancement of infrared images to display the image with a relatively satisfied contrast and brightness, rich detail information, and no artifacts caused by the image processing. We first adopt a propagated image filter to smooth the input image and separate the image into the base layer and the detail layer. Then, we refine the base layer by using modified histogram projection for compressing. Meanwhile, the adaptive weights derived from the layer decomposition processing are used as the strict gain control for the detail layer. The final display result is obtained by recombining the two modified layers. Experimental results on both cooled and uncooled infrared data verify that the proposed method outperforms the method based on log-power histogram modification and bilateral filter-based detail enhancement in both detail enhancement and visual effect.

  12. Field application of feature-enhanced imaging

    International Nuclear Information System (INIS)

    Mucciardi, A.N.

    1988-01-01

    One of the more challenging ultrasonic inspection problems is bimetallic weld inspection or, in general, dissimilar metal welds. These types of welds involve complicated geometries and various mixtures of materials. Attempts to address this problem with imaging alone have fallen short of desired goals. The probable reason for this is the lack of information supplied by imaging systems, which are limited to amplitude and time displays. Having RF information available for analysis greatly enhances the information obtainable from dissimilar metal welds and, coupled with the spatial map generated by an imaging system, can significantly improve the reliability of dissimilar metal weld inspections. Ultra Image and TestPro are, respectively, an imaging system and a feature-based signal analysis system. The purpose of this project is to integrate these two systems to produce a feature-enhanced imaging system. This means that a software link is established between Ultra Image and the PC-based TestPro system so that the user of the combined system can perform all the usual imaging functions and also have available a wide variety of RF signal analysis functions. The analysis functions include waveform feature-based pattern recognition as well as artificial intelligence/expert system techniques

  13. Fingerprint image enhancement by differential hysteresis processing.

    Science.gov (United States)

    Blotta, Eduardo; Moler, Emilce

    2004-05-10

    A new method to enhance defective fingerprints images through image digital processing tools is presented in this work. When the fingerprints have been taken without any care, blurred and in some cases mostly illegible, as in the case presented here, their classification and comparison becomes nearly impossible. A combination of spatial domain filters, including a technique called differential hysteresis processing (DHP), is applied to improve these kind of images. This set of filtering methods proved to be satisfactory in a wide range of cases by uncovering hidden details that helped to identify persons. Dactyloscopy experts from Policia Federal Argentina and the EAAF have validated these results.

  14. Nanoparticles as image enhancing agents for ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Liu Jun [Biomedical Engineering Department, Ohio State University, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH 43210 (United States); Levine, Andrea L [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Mattoon, John S [Department of Veterinary Clinical Sciences, Ohio State University, 1151 Veterinary Hospital, 601 Vernon Tharp St., Columbus, OH 43210 (United States); Yamaguchi, Mamoru [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Lee, Robert J [Division of Pharmaceutics, College of Pharmacy, NCI Comprehensive Cancer Center, and NSF Nanoscale Science and Engineering Center, Ohio State University, 500 West 12th Avenue, Columbus, OH 43210 (United States); Pan Xueliang [Department of Statistics, Ohio State University, 1958 Neil Avenue, Columbus, OH 43210 (United States); Rosol, Thomas J [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States)

    2006-05-07

    Nanoparticles have drawn great attention as targeted imaging and/or therapeutic agents. The small size of the nanoparticles allows them to target cells that are beyond capillary vasculature, such as cancer cells. We investigated the effect of solid nanoparticles for enhancing ultrasonic grey scale images in tissue phantoms and mouse livers in vivo. Silica nanospheres (100 nm) were dispersed in agarose at 1-2.5% mass concentration and imaged by a high-resolution ultrasound imaging system (transducer centre frequency: 30 MHz). Polystyrene particles of different sizes (500-3000 nm) and concentrations (0.13-0.75% mass) were similarly dispersed in agarose and imaged. Mice were injected intravenously with nanoparticle suspensions in saline. B-mode images of the livers were acquired at different time points after particle injection. An automated computer program was used to quantify the grey scale changes. Ultrasonic reflections were observed from nanoparticle suspensions in agarose gels. The image brightness, i.e., mean grey scale level, increased with particle size and concentration. The mean grey scale of mouse livers also increased following particle administration. These results indicated that it is feasible to use solid nanoparticles as contrast enhancing agents for ultrasonic imagin000.

  15. Resolution enhancement in medical ultrasound imaging.

    Science.gov (United States)

    Ploquin, Marie; Basarab, Adrian; Kouamé, Denis

    2015-01-01

    Image resolution enhancement is a problem of considerable interest in all medical imaging modalities. Unlike general purpose imaging or video processing, for a very long time, medical image resolution enhancement has been based on optimization of the imaging devices. Although some recent works purport to deal with image postprocessing, much remains to be done regarding medical image enhancement via postprocessing, especially in ultrasound imaging. We face a resolution improvement issue in the case of medical ultrasound imaging. We propose to investigate this problem using multidimensional autoregressive (AR) models. Noting that the estimation of the envelope of an ultrasound radio frequency (RF) signal is very similar to the estimation of classical Fourier-based power spectrum estimation, we theoretically show that a domain change and a multidimensional AR model can be used to achieve super-resolution in ultrasound imaging provided the order is estimated correctly. Here, this is done by means of a technique that simultaneously estimates the order and the parameters of a multidimensional model using relevant regression matrix factorization. Doing so, the proposed method specifically fits ultrasound imaging and provides an estimated envelope. Moreover, an expression that links the theoretical image resolution to both the image acquisition features (such as the point spread function) and a postprocessing feature (the AR model) order is derived. The overall contribution of this work is threefold. First, it allows for automatic resolution improvement. Through a simple model and without any specific manual algorithmic parameter tuning, as is used in common methods, the proposed technique simply and exclusively uses the ultrasound RF signal as input and provides the improved B-mode as output. Second, it allows for the a priori prediction of the improvement in resolution via the knowledge of the parametric model order before actual processing. Finally, to achieve the

  16. Standardisation of magnetic nanoparticles in liquid suspension

    Science.gov (United States)

    Wells, James; Kazakova, Olga; Posth, Oliver; Steinhoff, Uwe; Petronis, Sarunas; Bogart, Lara K.; Southern, Paul; Pankhurst, Quentin; Johansson, Christer

    2017-09-01

    Suspensions of magnetic nanoparticles offer diverse opportunities for technology innovation, spanning a large number of industry sectors from imaging and actuation based applications in biomedicine and biotechnology, through large-scale environmental remediation uses such as water purification, to engineering-based applications such as position-controlled lubricants and soaps. Continuous advances in their manufacture have produced an ever-growing range of products, each with their own unique properties. At the same time, the characterisation of magnetic nanoparticles is often complex, and expert knowledge is needed to correctly interpret the measurement data. In many cases, the stringent requirements of the end-user technologies dictate that magnetic nanoparticle products should be clearly defined, well characterised, consistent and safe; or to put it another way—standardised. The aims of this document are to outline the concepts and terminology necessary for discussion of magnetic nanoparticles, to examine the current state-of-the-art in characterisation methods necessary for the most prominent applications of magnetic nanoparticle suspensions, to suggest a possible structure for the future development of standardisation within the field, and to identify areas and topics which deserve to be the focus of future work items. We discuss potential roadmaps for the future standardisation of this developing industry, and the likely challenges to be encountered along the way.

  17. Standardisation of magnetic nanoparticles in liquid suspension

    International Nuclear Information System (INIS)

    Wells, James; Kazakova, Olga; Posth, Oliver; Steinhoff, Uwe; Petronis, Sarunas; Bogart, Lara K; Southern, Paul; Pankhurst, Quentin; Johansson, Christer

    2017-01-01

    Suspensions of magnetic nanoparticles offer diverse opportunities for technology innovation, spanning a large number of industry sectors from imaging and actuation based applications in biomedicine and biotechnology, through large-scale environmental remediation uses such as water purification, to engineering-based applications such as position-controlled lubricants and soaps. Continuous advances in their manufacture have produced an ever-growing range of products, each with their own unique properties. At the same time, the characterisation of magnetic nanoparticles is often complex, and expert knowledge is needed to correctly interpret the measurement data. In many cases, the stringent requirements of the end-user technologies dictate that magnetic nanoparticle products should be clearly defined, well characterised, consistent and safe; or to put it another way—standardised. The aims of this document are to outline the concepts and terminology necessary for discussion of magnetic nanoparticles, to examine the current state-of-the-art in characterisation methods necessary for the most prominent applications of magnetic nanoparticle suspensions, to suggest a possible structure for the future development of standardisation within the field, and to identify areas and topics which deserve to be the focus of future work items. We discuss potential roadmaps for the future standardisation of this developing industry, and the likely challenges to be encountered along the way. (topical review)

  18. Method and apparatus for enhancing radiometric imaging

    International Nuclear Information System (INIS)

    Logan, R. H.; Paradish, F. J.

    1985-01-01

    Disclosed is a method and apparatus for enhancing target detection, particularly in the millimeter wave frequency range, through the utilization of an imaging radiometer. The radiometer, which is a passive thermal receiver, detects the reflected and emitted thermal radiation of targets within a predetermined antenna/receiver beamwidth. By scanning the radiometer over a target area, a thermal image is created. At millimeter wave frequencies, the received emissions from the target area are highly dependent on the emissivity of the target of interest. Foliage will appear ''hot'' due to its high emissivity and metals will appear cold due to their low emissivities. A noise power illuminator is periodically actuated to illuminate the target of interest. When the illuminator is actuated, the role of emissivity is reversed, namely poorly emissive targets will generally be good reflectors which in the presence of an illuminator will appear ''hot''. The highly emissive targets (such as foliage and dirt) which absorb most of the transmitted energy will appear almost the same as in a nonilluminated, passive image. Using a data processor, the intensity of the passive image is subtracted from the intensity of the illuminated, active image which thereby cancels the background foliage, dirt, etc. and the reflective metallic targets are enhanced

  19. Standardisation of digital human models.

    Science.gov (United States)

    Paul, Gunther; Wischniewski, Sascha

    2012-01-01

    Digital human models (DHM) have evolved as useful tools for ergonomic workplace design and product development, and found in various industries and education. DHM systems which dominate the market were developed for specific purposes and differ significantly, which is not only reflected in non-compatible results of DHM simulations, but also provoking misunderstanding of how DHM simulations relate to real world problems. While DHM developers are restricted by uncertainty about the user need and lack of model data related standards, users are confined to one specific product and cannot exchange results, or upgrade to another DHM system, as their previous results would be rendered worthless. Furthermore, origin and validity of anthropometric and biomechanical data is not transparent to the user. The lack of standardisation in DHM systems has become a major roadblock in further system development, affecting all stakeholders in the DHM industry. Evidently, a framework for standardising digital human models is necessary to overcome current obstructions. Practitioner Summary: This short communication addresses a standardisation issue for digital human models, which has been addressed at the International Ergonomics Association Technical Committee for Human Simulation and Virtual Environments. It is the outcome of a workshop at the DHM 2011 symposium in Lyon, which concluded steps towards DHM standardisation that need to be taken.

  20. Image fusion for dynamic contrast enhanced magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Leach Martin O

    2004-10-01

    Full Text Available Abstract Background Multivariate imaging techniques such as dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI have been shown to provide valuable information for medical diagnosis. Even though these techniques provide new information, integrating and evaluating the much wider range of information is a challenging task for the human observer. This task may be assisted with the use of image fusion algorithms. Methods In this paper, image fusion based on Kernel Principal Component Analysis (KPCA is proposed for the first time. It is demonstrated that a priori knowledge about the data domain can be easily incorporated into the parametrisation of the KPCA, leading to task-oriented visualisations of the multivariate data. The results of the fusion process are compared with those of the well-known and established standard linear Principal Component Analysis (PCA by means of temporal sequences of 3D MRI volumes from six patients who took part in a breast cancer screening study. Results The PCA and KPCA algorithms are able to integrate information from a sequence of MRI volumes into informative gray value or colour images. By incorporating a priori knowledge, the fusion process can be automated and optimised in order to visualise suspicious lesions with high contrast to normal tissue. Conclusion Our machine learning based image fusion approach maps the full signal space of a temporal DCE-MRI sequence to a single meaningful visualisation with good tissue/lesion contrast and thus supports the radiologist during manual image evaluation.

  1. Appropriate Contrast Enhancement Measures for Brain and Breast Cancer Images

    Directory of Open Access Journals (Sweden)

    Suneet Gupta

    2016-01-01

    Full Text Available Medical imaging systems often produce images that require enhancement, such as improving the image contrast as they are poor in contrast. Therefore, they must be enhanced before they are examined by medical professionals. This is necessary for proper diagnosis and subsequent treatment. We do have various enhancement algorithms which enhance the medical images to different extents. We also have various quantitative metrics or measures which evaluate the quality of an image. This paper suggests the most appropriate measures for two of the medical images, namely, brain cancer images and breast cancer images.

  2. Depth image enhancement using perceptual texture priors

    Science.gov (United States)

    Bang, Duhyeon; Shim, Hyunjung

    2015-03-01

    A depth camera is widely used in various applications because it provides a depth image of the scene in real time. However, due to the limited power consumption, the depth camera presents severe noises, incapable of providing the high quality 3D data. Although the smoothness prior is often employed to subside the depth noise, it discards the geometric details so to degrade the distance resolution and hinder achieving the realism in 3D contents. In this paper, we propose a perceptual-based depth image enhancement technique that automatically recovers the depth details of various textures, using a statistical framework inspired by human mechanism of perceiving surface details by texture priors. We construct the database composed of the high quality normals. Based on the recent studies in human visual perception (HVP), we select the pattern density as a primary feature to classify textures. Upon the classification results, we match and substitute the noisy input normals with high quality normals in the database. As a result, our method provides the high quality depth image preserving the surface details. We expect that our work is effective to enhance the details of depth image from 3D sensors and to provide a high-fidelity virtual reality experience.

  3. Contrast enhanced ultrasound in liver imaging

    International Nuclear Information System (INIS)

    Nielsen, Michael Bachmann; Bang, Nanna

    2004-01-01

    Ultrasound contrast agents were originally introduced to enhance the Doppler signals when detecting vessels with low velocity flow or when imaging conditions were sub-optimal. Contrast agents showed additional properties, it was discovered that a parenchymal enhancement phase in the liver followed the enhancement of the blood pool. Contrast agents have made ultrasound scanning more accurate in detection and characterization of focal hepatic lesions and the sensitivity is now comparable with CT and MRI scanning. Further, analysis of the transit time of contrast agent through the liver seems to give information on possible hepatic involvement, not only from focal lesions but also from diffuse benign parenchymal disease. The first ultrasound contrast agents were easily destroyed by the energy from the sound waves but newer agents have proved to last for longer time and hereby enable real-time scanning and make contrast enhancement suitable for interventional procedures such as biopsies and tissue ablation. Also, in monitoring the effect of tumour treatment contrast agents have been useful. A brief overview is given on some possible applications and on different techniques using ultrasound contrast agents in liver imaging. At present, the use of an ultrasound contrast agent that allows real-time scanning with low mechanical index is to be preferred

  4. Detectability of hepatocellular carcinoma: comparison of Gd-DTPA-enhanced and SPIO-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Lee, Jeong Min; Kim In Hwan; Kim, Chong Soo; Han, Hyeun Young; Yoon, Kwon ha; Shin, Kyung Sook

    2000-01-01

    To compare the detectability of hepatocellular carcinoma (HCC) using superparamagnetic iron oxide (SPIO)-enhanced T2-weighted turbo spin echo (TSE), SPIO-enhanced T2-weighted FISP, and dynamic Gd-DTPA-enhanced fast low-angle shot (FLASH) MR images. In order to assess their hepatic lesions, 25 patients (20 men and 5 women) with HCC were enrolled in an MR study in which both gadolinium and Spiro were used. Since the lesions were most conspicuous during the phase of dynamic arterial dominant phase of dynamic gadolinium-enhanced imaging, this was the phase used for analysis. Images were analyzed qualitatively and quantitatively, and to compare the diagnostic value of gadolinium-enhanced imaging with that of SPIO-enhanced imaging for the detection of HCCs, a receiver-operated characteristic curve was obtained. Qualitative analysis revealed a significantly higher percentage of signal loss and a higher liver-lesion contrast-to-noise ratio on SPIO-enhanced FISP imaging than on SPIO-enhanced T2-weighted TSE imaging (p less than 0.05). It also showed that the lesions were most clearly visible on SPIO-enhanced FISP imaging (and significantly so), followed by SPIO-enhanced T2-weighted TSE imaging, and dynamic gadolinium-enhanced imaging. Imaging artifacts were more prominent on SPIO-enhanced T2-weighted TSE than on SPIO-enhanced PISF imaging or dynamic gadolinium-enhanced imaging (p less than 0.05). According to ROC analysis, SPIO-enhanced T2-weighted turbo spin echo (TSE) or SPIO-enhanced FISP imaging achieved higher accuracy than did dynamic gadolinium-enhanced FLASH imaging (p less than 0.05). For the detection of hepatocellular carcinomas, SPIO-enhanced MR imaging is better than gadolinium-enhanced FLASH imaging

  5. Standardisation of neonatal clinical practice.

    Science.gov (United States)

    Bhutta, Z A; Giuliani, F; Haroon, A; Knight, H E; Albernaz, E; Batra, M; Bhat, B; Bertino, E; McCormick, K; Ochieng, R; Rajan, V; Ruyan, P; Cheikh Ismail, L; Paul, V

    2013-09-01

    The International Fetal and Newborn Growth Consortium for the 21(st) Century (INTERGROWTH-21(st) ) is a large-scale, population-based, multicentre project involving health institutions from eight geographically diverse countries, which aims to assess fetal, newborn and preterm growth under optimal conditions. Given the multicentre nature of the project and the expected number of preterm births, it is vital that all centres follow the same standardised clinical care protocols to assess and manage preterm infants, so as to ensure maximum validity of the resulting standards as indicators of growth and nutrition with minimal confounding. Moreover, it is well known that evidence-based clinical practice guidelines can reduce the delivery of inappropriate care and support the introduction of new knowledge into clinical practice. The INTERGROWTH-21(st) Neonatal Group produced an operations manual, which reflects the consensus reached by members of the group regarding standardised definitions of neonatal morbidities and the minimum standards of care to be provided by all centres taking part in the project. The operational definitions and summary management protocols were developed by consensus through a Delphi process based on systematic reviews of relevant guidelines and management protocols by authoritative bodies. This paper describes the process of developing the Basic Neonatal Care Manual, as well as the morbidity definitions and standardised neonatal care protocols applied across all the INTERGROWTH-21(st) participating centres. Finally, thoughts about implementation strategies are presented. © 2013 Royal College of Obstetricians and Gynaecologists.

  6. Sequential contrast-enhanced MR imaging of the penis.

    Science.gov (United States)

    Kaneko, K; De Mouy, E H; Lee, B E

    1994-04-01

    To determine the enhancement patterns of the penis at magnetic resonance (MR) imaging. Sequential contrast material-enhanced MR images of the penis in a flaccid state were obtained in 16 volunteers (12 with normal penile function and four with erectile dysfunction). Subjects with normal erectile function showed gradual and centrifugal enhancement of the corpora cavernosa, while those with erectile dysfunction showed poor enhancement with abnormal progression. Sequential contrast-enhanced MR imaging provides additional morphologic information for the evaluation of erectile dysfunction.

  7. Comparative analysis of different methods for image enhancement

    Institute of Scientific and Technical Information of China (English)

    吴笑峰; 胡仕刚; 赵瑾; 李志明; 李劲; 唐志军; 席在芳

    2014-01-01

    Image enhancement technology plays a very important role to improve image quality in image processing. By enhancing some information and restraining other information selectively, it can improve image visual effect. The objective of this work is to implement the image enhancement to gray scale images using different techniques. After the fundamental methods of image enhancement processing are demonstrated, image enhancement algorithms based on space and frequency domains are systematically investigated and compared. The advantage and defect of the above-mentioned algorithms are analyzed. The algorithms of wavelet based image enhancement are also deduced and generalized. Wavelet transform modulus maxima (WTMM) is a method for detecting the fractal dimension of a signal, it is well used for image enhancement. The image techniques are compared by using the mean (μ), standard deviation (s), mean square error (MSE) and PSNR (peak signal to noise ratio). A group of experimental results demonstrate that the image enhancement algorithm based on wavelet transform is effective for image de-noising and enhancement. Wavelet transform modulus maxima method is one of the best methods for image enhancement.

  8. Tourism Industry And Standardisation: An Impossible Task?

    OpenAIRE

    BOZKURT, Alper

    2013-01-01

    Standardisation of a tourism industry offering will be discussed with this article in two different ways First by reviewing previous studies on the topic definitions of standardisation tourism industry and differences between a service and a goods product will be presented Second by interviewing managers from different tourism industry sectors possibility of a tourism product’s standardisation will be outlined Key words: standardisation service product goods product tourism indust...

  9. Gd-DTPA-enhanced MR imaging in meningitis

    International Nuclear Information System (INIS)

    Han, M.H.; Chang, K.H.; Roh, J.K.; Kim, I.O.; Han, M.C.; Kim, C.W.

    1988-01-01

    Gd-DPTA-enhanced MR imaging was performed in 16 patients with meningitis (seven tuberculous, four bacterial, three fungal, and two viral) on a 2.0-T unit. Hemorrhagic infarcts of basal ganglia and localized enhancement of thickened dura adjacent were demonstrated on T1-weighted images in three patients with tuberculous meningitis and four with bacterial meningitis, respectively, that were not seen on CT. Enhanced T1-weighted images readily differentiated leptomeningeal enhancement from vessels in two cases with CT of equivocal meningeal enhancement. Nonenhanced T2-weighted images were most sensitive for demonstrating ischemia/infarct and edema. Otherwise, MR images generally matched CT scans

  10. CMOS image sensor with contour enhancement

    Science.gov (United States)

    Meng, Liya; Lai, Xiaofeng; Chen, Kun; Yuan, Xianghui

    2010-10-01

    Imitating the signal acquisition and processing of vertebrate retina, a CMOS image sensor with bionic pre-processing circuit is designed. Integration of signal-process circuit on-chip can reduce the requirement of bandwidth and precision of the subsequent interface circuit, and simplify the design of the computer-vision system. This signal pre-processing circuit consists of adaptive photoreceptor, spatial filtering resistive network and Op-Amp calculation circuit. The adaptive photoreceptor unit with a dynamic range of approximately 100 dB has a good self-adaptability for the transient changes in light intensity instead of intensity level itself. Spatial low-pass filtering resistive network used to mimic the function of horizontal cell, is composed of the horizontal resistor (HRES) circuit and OTA (Operational Transconductance Amplifier) circuit. HRES circuit, imitating dendrite of the neuron cell, comprises of two series MOS transistors operated in weak inversion region. Appending two diode-connected n-channel transistors to a simple transconductance amplifier forms the OTA Op-Amp circuit, which provides stable bias voltage for the gate of MOS transistors in HRES circuit, while serves as an OTA voltage follower to provide input voltage for the network nodes. The Op-Amp calculation circuit with a simple two-stage Op-Amp achieves the image contour enhancing. By adjusting the bias voltage of the resistive network, the smoothing effect can be tuned to change the effect of image's contour enhancement. Simulations of cell circuit and 16×16 2D circuit array are implemented using CSMC 0.5μm DPTM CMOS process.

  11. Efficient OCT Image Enhancement Based on Collaborative Shock Filtering.

    Science.gov (United States)

    Liu, Guohua; Wang, Ziyu; Mu, Guoying; Li, Peijin

    2018-01-01

    Efficient enhancement of noisy optical coherence tomography (OCT) images is a key task for interpreting them correctly. In this paper, to better enhance details and layered structures of a human retina image, we propose a collaborative shock filtering for OCT image denoising and enhancement. Noisy OCT image is first denoised by a collaborative filtering method with new similarity measure, and then the denoised image is sharpened by a shock-type filtering for edge and detail enhancement. For dim OCT images, in order to improve image contrast for the detection of tiny lesions, a gamma transformation is first used to enhance the images within proper gray levels. The proposed method integrating image smoothing and sharpening simultaneously obtains better visual results in experiments.

  12. National aspects of nuclear standardisation

    International Nuclear Information System (INIS)

    Becker, K.

    1984-01-01

    The article first introduces the German Standards Institute (DIN) in figures and in its work, and gives details of the Nuclear Technology Committee (NK) which works with the Nuclear Committee. The German regulations consist of a total of about 220 documents, which cost about 18 million DM per annum. The use of nuclear standardisation can be seen in 1) a standardized, high safety level; 2) speeding up and simplifying the authorisation process; 3) improved acceptance; 4) means of technology transfer; 5) simplified trace across borders and 6) standardized requirements for plant near the border. (HSCH) [de

  13. HDR Pathological Image Enhancement Based on Improved Bias Field Correction and Guided Image Filter

    Directory of Open Access Journals (Sweden)

    Qingjiao Sun

    2016-01-01

    Full Text Available Pathological image enhancement is a significant topic in the field of pathological image processing. This paper proposes a high dynamic range (HDR pathological image enhancement method based on improved bias field correction and guided image filter (GIF. Firstly, a preprocessing including stain normalization and wavelet denoising is performed for Haematoxylin and Eosin (H and E stained pathological image. Then, an improved bias field correction model is developed to enhance the influence of light for high-frequency part in image and correct the intensity inhomogeneity and detail discontinuity of image. Next, HDR pathological image is generated based on least square method using low dynamic range (LDR image, H and E channel images. Finally, the fine enhanced image is acquired after the detail enhancement process. Experiments with 140 pathological images demonstrate the performance advantages of our proposed method as compared with related work.

  14. Image enhancement of digital periapical radiographs according to diagnostic tasks

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, Dankook University College of Dentistry, Cheonan (Korea, Republic of)

    2014-03-15

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  15. Image enhancement of digital periapical radiographs according to diagnostic tasks

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung

    2014-01-01

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  16. Gadolinium-enhanced MR imaging in evaluation of cholesteatoma

    International Nuclear Information System (INIS)

    Sugihara, M.; Sugimura, K.; Ishida, T.; Fujino, A.; Miyakuni, Y.

    1990-01-01

    It was sometimes difficult to differentiate cholesteatoma from accompanied granuloma, cholesterol granuloma, or mastoiditis on high-resolution CT. This study was designed to assess the reliability with which cholesteatoma can be differentiated from those accompanied lesions by gadolinium-enhanced MR imaging. Eight patients suspected to have cholesteatoma were evaluated with GD-DTPA-enhanced MR imaging with a 1.5-T MR imaging GE Signa unit. axial pre- and postcontrast T1-weighted (TR/TE, 600/20) and T2-weighted (TR/TE, 2,000/70) images were studied. MR imaging findings were compared with histologic findings (13 lesions), which included cholesteatoma (n = 6), granuloma (n = 4), cholesterol granuloma (n = 2), and mastoiditis (n = 1). Cholesteatoma had an intermediate to high signal intensity (SI) similar to that of granuloma on both T1- and T2-weighted images. Cholesterol granulomas showed high SI on both T1- and T2-weighted images. Mastoiditis demonstrated marked high SI on T2-weighted images. Cholesterol granuloma and mastoiditis can be distinguished from cholesteatoma or granuloma on both T1- and T2-weighted images. On Gd-DTPA-enhanced images, there was marked enhancement of all granulomas. However, no cholesteatoma enhancement was seen in all six lesions. Gd-DTPA-enhanced images were able to distinguish cholesteatoma from granuloma and to estimate the exact extent of cholesteatoma. Gd-DTPA-enhanced MR imaging is valuable in the evaluation and management of cholesteatoma

  17. Enhancement of Electroluminescence (EL) image measurements for failure quantification methods

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Enhanced quality images are necessary for EL image analysis and failure quantification. A method is proposed which determines image quality in terms of more accurate failure detection of solar panels through electroluminescence (EL) imaging technique. The goal of the paper is to determine the most...

  18. Mammographic image enhancement using wavelet transform and homomorphic filter

    Directory of Open Access Journals (Sweden)

    F Majidi

    2015-12-01

    Full Text Available Mammography is the most effective method for the early diagnosis of breast cancer diseases. As mammographic images contain low signal to noise ratio and low contrast, it becomes too difficult for radiologists to analyze mammogram. To deal with the above stated problems, it is very important to enhance the mammographic images using image processing methods. This paper introduces a new image enhancement approach for mammographic images which uses the modified mathematical morphology, wavelet transform and homomorphic filter to suppress the noise of images. For performance evaluation of the proposed method, contrast improvement index (CII and edge preservation index (EPI are adopted. Experimental results on mammographic images from Pejvak Digital Imaging Center (PDIC show that the proposed algorithm improves the two indexes, thereby achieving the goal of enhancing mammographic images.

  19. Natural Image Enhancement Using a Biogeography Based Optimization Enhanced with Blended Migration Operator

    Directory of Open Access Journals (Sweden)

    J. Jasper

    2014-01-01

    Full Text Available This paper addresses a novel and efficient algorithm for solving optimization problem in image processing applications. Image enhancement (IE is one of the complex optimization problems in image processing. The main goal of this paper is to enhance color images such that the eminence of the image is more suitable than the original image from the perceptual viewpoint of human. Traditional methods require prior knowledge of the image to be enhanced, whereas the aim of the proposed biogeography based optimization (BBO enhanced with blended migration operator (BMO algorithm is to maximize the objective function in order to enhance the image contrast by maximizing the parameters like edge intensity, edge information, and entropy. Experimental results are compared with the current state-of-the-art approaches and indicate the superiority of the proposed technique in terms of subjective and objective evaluation.

  20. Human body region enhancement method based on Kinect infrared imaging

    Science.gov (United States)

    Yang, Lei; Fan, Yubo; Song, Xiaowei; Cai, Wenjing

    2016-10-01

    To effectively improve the low contrast of human body region in the infrared images, a combing method of several enhancement methods is utilized to enhance the human body region. Firstly, for the infrared images acquired by Kinect, in order to improve the overall contrast of the infrared images, an Optimal Contrast-Tone Mapping (OCTM) method with multi-iterations is applied to balance the contrast of low-luminosity infrared images. Secondly, to enhance the human body region better, a Level Set algorithm is employed to improve the contour edges of human body region. Finally, to further improve the human body region in infrared images, Laplacian Pyramid decomposition is adopted to enhance the contour-improved human body region. Meanwhile, the background area without human body region is processed by bilateral filtering to improve the overall effect. With theoretical analysis and experimental verification, the results show that the proposed method could effectively enhance the human body region of such infrared images.

  1. Image Enhancement In HSI Space Using Wavelet Transform

    Science.gov (United States)

    Bansal, Sonia; Malhotra, Deepti

    2010-11-01

    Image processing modifies images to improve them (enhancement, restoration), extract information (analysis, recognition), and change their structure (composition, image editing). Image Enhancement is simple and most appealing area among all the digital image processing techniques. The main purpose of image enhancement is to bring out detail that is hidden in an image or to increase contrast in a low contrast image [1]. The color restoration functions of some real color image enhancement algorithms are greatly at random and not proved , and the real color images enhanced which are based on illumination-reflectance model have the loss of details and the `halos', we proposed a new algorithm to overcome these disadvantages. Firstly, we transform the real color image from RGB space to HSI space which is approximately orthonormal system. Secondly, the illumination and the reflectance of value are separated by homomorphic filtering based on illumination-reflectance model. We have discovered that the high dynamic range of image including high bright lights is mainly caused by the reflectance. Thirdly, the details of reflectance are preserved by wavelet transform. Fourthly, the dynamic range of reflectance is compressed by Butterworth filtering. Lastly, the energy of the saturation of real color image in HSI space is attenuated according to the spectral sensitivity of most human vision.

  2. Dissuasive cigarette sticks: the next step in standardised ('plain') packaging?

    Science.gov (United States)

    Hoek, Janet; Gendall, Philip; Eckert, Christine; Louviere, Jordan

    2016-11-01

    Standardised (or 'plain') packaging has reduced the appeal of smoking by removing imagery that smokers use to affiliate themselves with the brand they smoke. We examined whether changing the appearance of cigarette sticks could further denormalise smoking and enhance the negative impact of standardised packaging. We conducted an online study of 313 New Zealand smokers who comprised a Best-Worst Choice experiment and a rating task. The Best-Worst experiment used a 2×3×3×6 orthogonal design to test the following attributes: on-pack warning message, branding level, warning size and stick appearance. We identified three segments whose members' choice patterns were strongly influenced by the stick design, warning theme and size, and warning theme, respectively. Each of the dissuasive sticks tested was less preferred and rated as less appealing than the most common stick in use; a 'minutes of life lost' stick was the most aversive of the stimuli tested. Dissuasive sticks could enhance the effect of standardised packaging, particularly among older smokers who are often more heavily addicted and resistant to change. Countries introducing standardised packaging legislation should take the opportunity to denormalise the appearance of cigarette sticks, in addition to removing external tobacco branding from packs and increasing the warning size. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. A Fuzzy Homomorphic Algorithm for Image Enhancement | Nnolim ...

    African Journals Online (AJOL)

    The implementation and analysis of a novel Fuzzy Homomorphic image enhancement technique is presented. The technique combines the logarithmic transform with fuzzy membership functions to deliver an intuitive method of image enhancement. This algorithm reduces the computational complexity by eliminating the ...

  4. Neutron Activation Analysis with k0-standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    2001-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation concentrates on the improvement of the standardisation method and the characterisation of the neutron field as well as on the improvement of the statistical control on neutron activation analysis. Main achievements in 2000 are reported

  5. Oxygen-enhanced magnetic resonance ventilation imaging of lung

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Chen Qun; Hatabu, Hiroto

    2001-01-01

    The oxygen-enhanced magnetic resonance (MR) ventilation imaging is a new technique, and the full extent of its physiological significance has not been elucidated. This review article includes background on (1) respiratory physiology; (2) mechanism and optimization of oxygen-enhanced MR imaging technique; (3) recent applications in animal and human models; and (4) merits and demerits of the technique in comparison with hyperpolarized noble gas MR ventilation imaging. Application of oxygen-enhanced MR ventilation imaging to patients with pulmonary diseases has been very limited. However, we believe that further basic studies, as well as clinical applications of this new technique will define the real significance of oxygen-enhanced MR ventilation imaging in the future of pulmonary functional imaging and its usefulness for diagnostic radiology

  6. COLOUR IMAGE ENHANCEMENT BASED ON HISTOGRAM EQUALIZATION

    OpenAIRE

    Kanika Kapoor and Shaveta Arora

    2015-01-01

    Histogram equalization is a nonlinear technique for adjusting the contrast of an image using its histogram. It increases the brightness of a gray scale image which is different from the mean brightness of the original image. There are various types of Histogram equalization techniques like Histogram Equalization, Contrast Limited Adaptive Histogram Equalization, Brightness Preserving Bi Histogram Equalization, Dualistic Sub Image Histogram Equalization, Minimum Mean Brightness Error Bi Histog...

  7. Image enhancement technology research for army applications

    NARCIS (Netherlands)

    Schwering, P.B.W.; Kemp, R.A.W.; Schutte, K.

    2013-01-01

    Recognition and identification ranges are limited to the quality of the images. Both the received contrast and the spatial resolution determine if objects are recognizable. Several aspects affect the image quality. First of all the sensor itself. The image quality depends on the size of the infrared

  8. Subendometrial enhancement and peritumoral enhancement for assessing endometrial cancer on dynamic contrast enhanced MR imaging

    International Nuclear Information System (INIS)

    Fujii, Shinya; Kido, Aki; Baba, Tsukasa; Fujimoto, Koji; Daido, Sayaka; Matsumura, Noriomi; Konishi, Ikuo; Togashi, Kaori

    2015-01-01

    Highlights: •We have assessed the peritumoral enhancement (PTE), which mimics SEE on DCE. •We evaluated the diagnostic accuracy of SEE for the myometrial invasion and the frequency of PTE. •We assessed the relationship between these enhancements and important pathologic factors. •PTE Type 1 is the main factor causing the overestimation of myometrial invasion using SEE on DCE. •PTE Type 2 correlates the myometrial invasion and may play an important role in the diagnosis of LVSI. -- Abstract: Objectives: To evaluate the diagnostic accuracy of subendometrial enhancement (SEE) in assessing the myometrial invasion in endometrial cancer, the frequency and clinical significance of peritumoral enhancement (PTE) on dynamic contrast enhanced (DCE) imaging. Materials and methods: MR images of 147 patients with endometrial cancer were retrospectively analyzed for intact SEE and PTEs: Type 1, a focal early enhancement peritumorally, and Type 2, an irregular thin-layered early intense enhancement peritumorally. Two radiologists independently assessed intact SEE and PTEs on DCE imaging and compared the lesions by the presence and depth of myometrial invasion, grade, lymphovascular space involvement (LVSI), and lymph node metastasis. The relationship between SEE, PTEs, and each factor was analyzed using univariate and multivariate analyses. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for SEE. Results: The sensitivity, specificity, PPV, NPV and diagnostic accuracy for myometrial invasion based on SEE disruption on DCE were 96.6%, 32.1–46.4%, 85.8–88.5%, 69.2–76.5%, and 84.4–87.1%. According to multivariate analysis, SEE significantly predicted myometrial invasion (p < 0.0001). PTE Type 2 significantly predicted myometrial invasion presence (p < 0.05) and depth (p < 0.01). Conclusion: Diagnosis of myometrial invasion only by using SEE might be difficult on DCE-MRI due to the

  9. Subendometrial enhancement and peritumoral enhancement for assessing endometrial cancer on dynamic contrast enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Shinya [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, Yonago (Japan); Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Kido, Aki, E-mail: akikido@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Baba, Tsukasa [Departments of Gynecology and Obstetrics, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Fujimoto, Koji; Daido, Sayaka [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Matsumura, Noriomi; Konishi, Ikuo [Departments of Gynecology and Obstetrics, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan)

    2015-04-15

    Highlights: •We have assessed the peritumoral enhancement (PTE), which mimics SEE on DCE. •We evaluated the diagnostic accuracy of SEE for the myometrial invasion and the frequency of PTE. •We assessed the relationship between these enhancements and important pathologic factors. •PTE Type 1 is the main factor causing the overestimation of myometrial invasion using SEE on DCE. •PTE Type 2 correlates the myometrial invasion and may play an important role in the diagnosis of LVSI. -- Abstract: Objectives: To evaluate the diagnostic accuracy of subendometrial enhancement (SEE) in assessing the myometrial invasion in endometrial cancer, the frequency and clinical significance of peritumoral enhancement (PTE) on dynamic contrast enhanced (DCE) imaging. Materials and methods: MR images of 147 patients with endometrial cancer were retrospectively analyzed for intact SEE and PTEs: Type 1, a focal early enhancement peritumorally, and Type 2, an irregular thin-layered early intense enhancement peritumorally. Two radiologists independently assessed intact SEE and PTEs on DCE imaging and compared the lesions by the presence and depth of myometrial invasion, grade, lymphovascular space involvement (LVSI), and lymph node metastasis. The relationship between SEE, PTEs, and each factor was analyzed using univariate and multivariate analyses. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for SEE. Results: The sensitivity, specificity, PPV, NPV and diagnostic accuracy for myometrial invasion based on SEE disruption on DCE were 96.6%, 32.1–46.4%, 85.8–88.5%, 69.2–76.5%, and 84.4–87.1%. According to multivariate analysis, SEE significantly predicted myometrial invasion (p < 0.0001). PTE Type 2 significantly predicted myometrial invasion presence (p < 0.05) and depth (p < 0.01). Conclusion: Diagnosis of myometrial invasion only by using SEE might be difficult on DCE-MRI due to the

  10. Gd-enhanced MR imaging of the herniated lumbar disc: patterns of enhancement

    International Nuclear Information System (INIS)

    Kwag, Hyon Joo; Choi, Hye Young; Kim, Hyae Young; Kim, Yoo Kyung; Kim, Ah Young; Chung, Eun Chul

    1995-01-01

    The purpose of this study is to describe the patterns of enhancement of the herniated lumbar disc with Gd-DTPA enhanced MR imaging. Out of 65 patients, 103 lumbar discs diagnosed to be herniated by MR image were retrospectively analyzed. The MR imaging was performed with 1.5 T MR unit, using T1-and T2-weighted sagittal and axial spin echo techniques. Contrast-enhanced T1 weighted sagittal and axial images were performed after intravenous injection of Gadopentetate-dimeglumine(Magnevist, Shering) (0.1 mmol/kg). Contrast enhancement was seen in 66 cases(64%). Thirteen cases of bulging disc were not enhanced. Twenty-eight cases of protruded disc showed intraannular enchantment in 23 cases, peripheral linear and irregular enhancement in each of one case, and nonenhancement in three cases. Fifty-seven cases of extruded disc showed irregular enhancement in 14 cases, peripheral linear enhancement in 12 cases, peripheral ring enhancement in five cases and intraannular enhancement in five cases. All five cases of sequestered disc showed peripheral ring enhancement. Protruded discs show intraannular enhancement frequently and sequestered discs usually show peripheral ring enhancement. Enhanced MR imaging may be helpful to evaluate the type of herniated lumbar disc and relationship among disc material, nerve root and thecal sac

  11. Algorithms for contrast enhancement of electronic portal images

    International Nuclear Information System (INIS)

    Díez, S.; Sánchez, S.

    2015-01-01

    An implementation of two new automatized image processing algorithms for contrast enhancement of portal images is presented as suitable tools which facilitate the setup verification and visualization of patients during radiotherapy treatments. In the first algorithm, called Automatic Segmentation and Histogram Stretching (ASHS), the portal image is automatically segmented in two sub-images delimited by the conformed treatment beam: one image consisting of the imaged patient obtained directly from the radiation treatment field, and the second one is composed of the imaged patient outside it. By segmenting the original image, a histogram stretching can be independently performed and improved in both regions. The second algorithm involves a two-step process. In the first step, a Normalization to Local Mean (NLM), an inverse restoration filter is applied by dividing pixel by pixel a portal image by its blurred version. In the second step, named Lineally Combined Local Histogram Equalization (LCLHE), the contrast of the original image is strongly improved by a Local Contrast Enhancement (LCE) algorithm, revealing the anatomical structures of patients. The output image is lineally combined with a portal image of the patient. Finally the output images of the previous algorithms (NLM and LCLHE) are lineally combined, once again, in order to obtain a contrast enhanced image. These two algorithms have been tested on several portal images with great results. - Highlights: • Two Algorithms are implemented to improve the contrast of Electronic Portal Images. • The multi-leaf and conformed beam are automatically segmented into Portal Images. • Hidden anatomical and bony structures in portal images are revealed. • The task related to the patient setup verification is facilitated by the contrast enhancement then achieved.

  12. Sonar Image Enhancements for Improved Detection of Sea Mines

    DEFF Research Database (Denmark)

    Jespersen, Karl; Sørensen, Helge Bjarup Dissing; Zerr, Benoit

    1999-01-01

    In this paper, five methods for enhancing sonar images prior to automatic detection of sea mines are investigated. Two of the methods have previously been published in connection with detection systems and serve as reference. The three new enhancement approaches are variance stabilizing log...... transform, nonlinear filtering, and pixel averaging for speckle reduction. The effect of the enhancement step is tested by using the full prcessing chain i.e. enhancement, detection and thresholding to determine the number of detections and false alarms. Substituting different enhancement algorithms...... in the processing chain gives a precise measure of the performance of the enhancement stage. The test is performed using a sonar image database with images ranging from very simple to very complex. The result of the comparison indicates that the new enhancement approaches improve the detection performance....

  13. Color enhancement in multispectral image of human skin

    Science.gov (United States)

    Mitsui, Masanori; Murakami, Yuri; Obi, Takashi; Yamaguchi, Masahiro; Ohyama, Nagaaki

    2003-07-01

    Multispectral imaging is receiving attention in medical color imaging, as high-fidelity color information can be acquired by the multispectral image capturing. On the other hand, as color enhancement in medical color image is effective for distinguishing lesion from normal part, we apply a new technique for color enhancement using multispectral image to enhance the features contained in a certain spectral band, without changing the average color distribution of original image. In this method, to keep the average color distribution, KL transform is applied to spectral data, and only high-order KL coefficients are amplified in the enhancement. Multispectral images of human skin of bruised arm are captured by 16-band multispectral camera, and the proposed color enhancement is applied. The resultant images are compared with the color images reproduced assuming CIE D65 illuminant (obtained by natural color reproduction technique). As a result, the proposed technique successfully visualizes unclear bruised lesions, which are almost invisible in natural color images. The proposed technique will provide support tool for the diagnosis in dermatology, visual examination in internal medicine, nursing care for preventing bedsore, and so on.

  14. Image enhancement by using IDL for a mammographic x-ray image in Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Md Saion Salikin; Wan Hazlinda Ismail; Norriza Mohd Isa; Azuhar Ripin

    2004-01-01

    Digital image enhancement technique can have a significant impact on the diagnostic quality of a radiographic image. The main aim of image enhancement is to process the image so that the enhanced image is clearer and more useful for specific application. There are three types of image enhancement namely noise reduction, edge enhancement and contrast enhancement. The objective of this project is to enhance the mammographic image by using Interactive Data Language (IDL) software in spatial and frequency domain by using various methods. In spatial domain method, direct manipulation of pixel in an image is used whereas, in frequency domain method, modifying the spectral component or Fourier Transform of an image is used In order to obtain the good quality mammographic image, breast phantom Model 12A with 4.0 cm compressed thickness and Bennett Model DMF- 150 Mammography Machine with various kV and mA are employed. The results of enhanced image with selected technique by using IDL are presented in this paper. (Author)

  15. Structure and morphology of mythimna pupa under diffraction enhanced imaging

    International Nuclear Information System (INIS)

    Huang Wanxia; Yuan Qingxi; Zhu Peiping; Wang Junyue; Liu Yijin; Chen Bo; Shu Hang; Hu Tiandou; Wu Ziyu; Ge Siqin

    2007-01-01

    As a technique of X-ray phase contrast imaging, the diffraction enhanced imaging (DEI) attracts much interest due to its high resolution and contrast. The top images of DEI were used to study the growth of a complete metamorphic mythimna in the period of pupa. Clear images about the pupa structure were obtained. The entire growth process of the pupa was observed, including the evolvement of part of organs and tissues from larva to imago. (authors)

  16. Screened Poisson Equation for Image Contrast Enhancement

    Directory of Open Access Journals (Sweden)

    Jean-Michel Morel

    2014-03-01

    Full Text Available In this work we propose a discussion and detailed implementation of a very simple gradient domain method that tries to eliminate the effect of nonuniform illumination and at the same time preserves the images details. This model, which to the best of our knowledge has not been explored in spite of its simplicity, acts as a high pass filter. We show that with a single contrast parameter (which keeps the same value in most experiments, the model delivers state of the art results. They compare favorably to results obtained with more complex algorithms. Our algorithm is designed for all kinds of images, but with the special specification of making minimal image detail alteration thanks to a first order fidelity term, instead of the usual zero order term. Experiments on non-uniform medical images and on hazy images illustrate significant perception gain.

  17. Terminology standardisation in the nuclear engineering field

    International Nuclear Information System (INIS)

    Kraut, A.

    1987-01-01

    Terminological standardisation is made for the purpose of unambiguous understanding, at least among experts in a given field of knowledge. The author explains a number of criteria and aspects to be taken into account in the process of standardisation by referring to the work of the Terminology Committee on Nuclear Engineering. He discusses the word formation in a technical language and the features of standardised terminology. Accepted terminology is a main factor in all procedures concerning design, testing, and approval and licensing of nuclear facilities, and also is of importance in terms of economics. (HP) [de

  18. Biometric image enhancement using decision rule based image fusion techniques

    Science.gov (United States)

    Sagayee, G. Mary Amirtha; Arumugam, S.

    2010-02-01

    Introducing biometrics into information systems may result in considerable benefits. Most of the researchers confirmed that the finger print is widely used than the iris or face and more over it is the primary choice for most privacy concerned applications. For finger prints applications, choosing proper sensor is at risk. The proposed work deals about, how the image quality can be improved by introducing image fusion technique at sensor levels. The results of the images after introducing the decision rule based image fusion technique are evaluated and analyzed with its entropy levels and root mean square error.

  19. Gadolinium-enhanced MR imaging in evaluation of Bell palsy

    International Nuclear Information System (INIS)

    Wang, A.M.; Wesolowski, D.P.; Bojrab, D.I.; Ernstoff, R.M.; Farah, J.

    1989-01-01

    Eight patients with Bell palsy were evaluated with Gd-DTPA (Magnevist)-enhanced MR imaging in a 1.0-T Siemen's Magnetom unit. Axial pre-and postcontrast and coronal postcontrast T1-weighted MR images of facial nerves were studied. Significant unilateral enhancement of the facial nerve within the internal auditory canal, with or without involvement of the geniculate ganglia, was found in six patients. Three of these patients without satisfactory response to medical treatment underwent surgical decompression, with excellent recovery of facial nerve function. The authors believe that gadolinium-enhanced MR imaging is valuable in the evaluation and management of Bell palsy

  20. Enhancement of dental x-ray images by two channel image processing

    International Nuclear Information System (INIS)

    Mitra, S.; Yu, T.H.

    1991-01-01

    In this paper, the authors develop a new algorithm for the enhancement of low-contrast details of dental X-ray images using a two channel structure. The algorithm first decomposes an input image in the frequency domain into two parts by filtering: one containing the low frequency components and the other containing the high frequency components. Then these parts are enhanced separately using a transform magnitude modifier. Finally a contrast enhanced image is formed by combining these two processed pats. The performance of the proposed algorithm is illustrated through enhancement of dental X-ray images. The algorithm can be easily implemented on a personal computer

  1. MR imaging of gestational trophoblastic tumor: role of gadolinium enhancement

    International Nuclear Information System (INIS)

    Choi, Si Young; Byun, Jae Young; Kim, Bum Su; Yun, Young Hyun; Mun, Kyung Mi; Park, Kyung Sin; Kim, Byung Kee; Bae, Seog Nyeon; Shinn, Kyung Sub.

    1997-01-01

    The purpose of this study is to investigate the role of gadolinium enhanced MR imaging in the evaluation of gestational trophoblastic tumors (invasive mole and choriocarcinoma). Pre-enhanced T1-and T2-weighted images and gadolinium enhanced T1-weighted images of 34 gestational trophoblastic tumors (15 choriocarcinomas, 19 invasive moles) were retrospectively evaluated and enhancement patterns were analyzed. Morphologica differences and structural characteristics were analyzed by the evaluation of tumor margin, patterns of hemorrhagic necroses, the development of intratumoral vascularity, and molar villi. Graded scores of MR findings between pre- and gadolinium enhanced images were based on the following criteria : 1) visualization of tumor margin 2) distinction between tumor necrosis and zone of trophoblastic proliferation ; and 3) molar villi. Statistical differences between graded scores of pre- and post-enhanced images were analyzed. Gadolinium enhanced MR imaging was helpful for the visualization of tumor characteristics in gestational trophoblastic tumors and in differential diagnosis between invasive mole and choriocarcinoma. (author). 16 refs., 4 tabs., 4 figs

  2. Fingerprint Image Enhancement Based on Second Directional Derivative of the Digital Image

    Directory of Open Access Journals (Sweden)

    Onnia Vesa

    2002-01-01

    Full Text Available This paper presents a novel approach of fingerprint image enhancement that relies on detecting the fingerprint ridges as image regions where the second directional derivative of the digital image is positive. A facet model is used in order to approximate the derivatives at each image pixel based on the intensity values of pixels located in a certain neighborhood. We note that the size of this neighborhood has a critical role in achieving accurate enhancement results. Using neighborhoods of various sizes, the proposed algorithm determines several candidate binary representations of the input fingerprint pattern. Subsequently, an output binary ridge-map image is created by selecting image zones, from the available binary image candidates, according to a MAP selection rule. Two public domain collections of fingerprint images are used in order to objectively assess the performance of the proposed fingerprint image enhancement approach.

  3. Research on Wavelet-Based Algorithm for Image Contrast Enhancement

    Institute of Scientific and Technical Information of China (English)

    Wu Ying-qian; Du Pei-jun; Shi Peng-fei

    2004-01-01

    A novel wavelet-based algorithm for image enhancement is proposed in the paper. On the basis of multiscale analysis, the proposed algorithm solves efficiently the problem of noise over-enhancement, which commonly occurs in the traditional methods for contrast enhancement. The decomposed coefficients at same scales are processed by a nonlinear method, and the coefficients at different scales are enhanced in different degree. During the procedure, the method takes full advantage of the properties of Human visual system so as to achieve better performance. The simulations demonstrate that these characters of the proposed approach enable it to fully enhance the content in images, to efficiently alleviate the enhancement of noise and to achieve much better enhancement effect than the traditional approaches.

  4. Enhanced refractor imaging by supervirtual interferometry

    KAUST Repository

    Mallinson, Ian; Bharadwaj, Pawan; Schuster, Gerard T.; Jakubowicz, Helmut

    2011-01-01

    Refraction surveys are a well-established method of imaging subsurface velocities, both in terms of the deep crustal structure at global scales and in the shallow near surface. These surveys generally involve deploying an array of receivers

  5. Image fusion for enhanced forest structural assessment

    CSIR Research Space (South Africa)

    Roberts, JW

    2011-01-01

    Full Text Available This research explores the potential benefits of fusing active and passive medium resolution satellite-borne sensor data for forest structural assessment. Image fusion was applied as a means of retaining disparate data features relevant to modeling...

  6. Hepatic enhancement on Gd-BOPTA-enhanced MR imaging: comparison between cirrhotic and normal livers

    International Nuclear Information System (INIS)

    Shin, Sang Soo; Jeong, Yong Yeon; Kang, Heoung Keun; Lim, Hyo Soon; Yoon, Woong; Seo, Jeong Jin; Park, Jin Gyoon

    2004-01-01

    To compare the enhancement features of hepatic parenchyma between cirrhotic and normal liver, using Gd-BOPTA-enhanced delayed MR imaging. The 60 patients (35 with cirrhotic and 25 with normal liver) included in our study underwent Gd-BOPTA-enhanced MR imaging using a 1.5T system with a phase-array multicoil. In all cases, T1-weighted in-phase and opposed-phase gradient-echo MR imaging was performed before and 60 minutes after intravenous administration of a bolus of Gd-BOPTA. All images were quantitatively analysed by comparing the signal-to-noise ratio (SNR) and signal enhancement (SE) of cirrhotic and normal liver before and after contrast enhancement, and in cirrhotic patients, SNR and SE were also compared in terms of the Child-Pugh classification. For qualitative analysis, the hepatic enhancement patterns of cirrhotic and normal liver were classified as homogeneous or heterogeneous according to the consensual findings of two radiologists. At contrast-enhanced imaging, both cirrhotic (p<0.001) and normal liver (p<0.001) showed substantially increased SNR relative to unenhanced images, and the SNR of cirrhotic liver was significantly lower than that of normal livers at both in-phase (p<0.001) and opposed-phase (p<0.001) imaging. The SE of cirrhotic liver was significantly lower than that of normal liver (in-phase:p=0.002; opposed phase:p=0.011). Both Child-Pugh class A (p<0.001) and B (p<0.001) cirrhotic liver showed a substantial increase in SNR at contrast-enhanced imaging relative to unenhanced imaging and the SNR of Child-Pugh class A was significantly higher than that of Child-Pugh class B at both in-phase (p<0.001) and opposed-phase (p=0.022) imaging. In addition, the SE of class A was significantly higher than that of class B at in-phase imaging (p=0.004). Cirrhotic liver showed heterogeneous enhancement in 20 of 35 patients (57%), whereas normal liver showed homogeneous enhancement in all patients. At Gd-BOPTA-enhanced delayed MR imaging, cirrhotic liver

  7. Standardised patient-simulated practice learning

    African Journals Online (AJOL)

    Teaching strategies must link theory to practice, foster critical thinking, be relevant and stimulate ... Standardised patient-simulated practice learning: A rich pedagogical .... relationship for them to grow and develop from novice to expert. They.

  8. Governance of electrotechnical standardisation in Europe

    NARCIS (Netherlands)

    H.J. de Vries (Henk)

    2015-01-01

    markdownabstract__Abstract__ This report provides recommendations about the governance of electrotechnical standardisation in Europe to seven independent National Committees: DKE (Germany), Electrosuisse (Switzerland), OVE (Austria), NEC (the Netherlands), NEK (Norway), SEK (Sweden), and SESKO

  9. Oxygen tolerance test : A standardised protocol

    Directory of Open Access Journals (Sweden)

    D K Ghosh

    2015-01-01

    Conclusion: By following a standardised protocol for Oxygen Tolerance Test, an objective assessment and recordkeeping is possible. This shall entail a more effective screening during the initial diving medical examination.

  10. The relationship between standardised test performance and ...

    African Journals Online (AJOL)

    The English language proficiency of South African learners is integral to ... in standardised reading/writing tests in English Second Language (ESL) and (2) the use of ... and their relationship with the ESL learner's language learning strategies.

  11. Microwave Imaging of Human Forearms: Pilot Study and Image Enhancement

    Directory of Open Access Journals (Sweden)

    Colin Gilmore

    2013-01-01

    Full Text Available We present a pilot study using a microwave tomography system in which we image the forearms of 5 adult male and female volunteers between the ages of 30 and 48. Microwave scattering data were collected at 0.8 to 1.2 GHz with 24 transmitting and receiving antennas located in a matching fluid of deionized water and table salt. Inversion of the microwave data was performed with a balanced version of the multiplicative-regularized contrast source inversion algorithm formulated using the finite-element method (FEM-CSI. T1-weighted MRI images of each volunteer’s forearm were also collected in the same plane as the microwave scattering experiment. Initial “blind” imaging results from the utilized inversion algorithm show that the image quality is dependent on the thickness of the arm’s peripheral adipose tissue layer; thicker layers of adipose tissue lead to poorer overall image quality. Due to the exible nature of the FEM-CSI algorithm used, prior information can be readily incorporated into the microwave imaging inversion process. We show that by introducing prior information into the FEM-CSI algorithm the internal anatomical features of all the arms are resolved, significantly improving the images. The prior information was estimated manually from the blind inversions using an ad hoc procedure.

  12. Magnetic resonance image enhancement using V-filter

    International Nuclear Information System (INIS)

    Yamamoto, H.; Sugita, K.; Kanzaki, N.; Johja, I.; Hiraki, Y.

    1990-01-01

    The purpose of this study is to present a method of boundary enhancement algorithms for magnetic resonance images using a V-filter. The boundary of the brain tumor was precisely extracted by the region segmentation techniques

  13. Facial nerve palsy: Evaluation by contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kinoshita, T.; Ishii, K.; Okitsu, T.; Okudera, T.; Ogawa, T.

    2001-01-01

    AIM: The purpose of this study was to investigate the value of contrast-enhanced magnetic resonance (MR) imaging in patients with peripheral facial nerve palsy. MATERIALS AND METHODS: MR imaging was performed in 147 patients with facial nerve palsy, using a 1.0 T unit. All of 147 patients were evaluated by contrast-enhanced MR imaging and the pattern of enhancement was compared with that in 300 control subjects evaluated for suspected acoustic neurinoma. RESULTS: The intrameatal and labyrinthine segments of the normal facial nerve did not show enhancement, whereas enhancement of the distal intrameatal segment and the labyrinthine segment was respectively found in 67% and 43% of patients with Bell's palsy. The geniculate ganglion or the tympanic-mastoid segment was enhanced in 21% of normal controls versus 91% of patients with Bell's palsy. Abnormal enhancement of the non-paralyzed facial nerve was found in a patient with bilateral temporal bone fracture. CONCLUSION: Enhancement of the distal intrameatal and labyrinthine segments is specific for facial nerve palsy. Contrast-enhanced MR imaging can reveal inflammatory facial nerve lesions and traumatic nerve injury, including clinically silent damage in trauma. Kinoshita T. et al. (2001)

  14. Facial nerve palsy: Evaluation by contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, T.; Ishii, K.; Okitsu, T.; Okudera, T.; Ogawa, T

    2001-11-01

    AIM: The purpose of this study was to investigate the value of contrast-enhanced magnetic resonance (MR) imaging in patients with peripheral facial nerve palsy. MATERIALS AND METHODS: MR imaging was performed in 147 patients with facial nerve palsy, using a 1.0 T unit. All of 147 patients were evaluated by contrast-enhanced MR imaging and the pattern of enhancement was compared with that in 300 control subjects evaluated for suspected acoustic neurinoma. RESULTS: The intrameatal and labyrinthine segments of the normal facial nerve did not show enhancement, whereas enhancement of the distal intrameatal segment and the labyrinthine segment was respectively found in 67% and 43% of patients with Bell's palsy. The geniculate ganglion or the tympanic-mastoid segment was enhanced in 21% of normal controls versus 91% of patients with Bell's palsy. Abnormal enhancement of the non-paralyzed facial nerve was found in a patient with bilateral temporal bone fracture. CONCLUSION: Enhancement of the distal intrameatal and labyrinthine segments is specific for facial nerve palsy. Contrast-enhanced MR imaging can reveal inflammatory facial nerve lesions and traumatic nerve injury, including clinically silent damage in trauma. Kinoshita T. et al. (2001)

  15. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    International Nuclear Information System (INIS)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon

    1994-01-01

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days

  16. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon [Inje University College of Medicine, Pusan (Korea, Republic of)

    1994-08-15

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days.

  17. China and Global ICT standardisation and innovation

    OpenAIRE

    Williams, Robin; Graham, Ian; Jakobs, Kai; Lyytinen, Kalle

    2011-01-01

    The People's Republic of China has become remarkably active in the development of interoperability standards across many areas of information and communications technology (ICT). Such standards are crucial for the creation of newindustries and markets for novel ICT products and services. This engagement in standardisation is linked to the Chinese government's strategy to develop indigenous technologies and, in some cases through involvement in international standardisation bodies, to put Chin...

  18. Enhanced tumor imaging with pokeweed mitogen

    International Nuclear Information System (INIS)

    Bitner, D.M.; Mann, P.L.; D'Souza, P.; Wenk, R.; Baughman, D.G.; Quesada, S.M.; Purvis, R.; Born, J.L.; Matwiyoff, N.A.; Eshima, D.

    1993-01-01

    Traditional tumor imaging with biotracer techniques relies solely on the target specificity of the biomolecule. We hypothesize that specific imaging is possible by altering the rate of tissue clearance of any given radiotracer. Pokeweed mitogen (PWM) as a biomodulator, represents a class of molecules which regulate cellular differentiation and cell-cell interactions and, as part of these mechanisms alter tissue clearance rates. Utilizing the B-16/C57BL/6 model, 7 days post-transplantation, 10 animals were imaged following an i.v. injection of 1-2 mCi 99m Tc-PWM in order to visualize the tumors and determine the optimal imaging kinetics. A specific tumor image is achieved between 120 and 240 min post-injection. In addition, tumor imaging studies using a non-tumor-specific biomolecule were conducted by injecting 19 animals i.v. with 1-2 mCi of 99m Tc-human serum albumin (HSA). Twelve of these animals were given 10 μg of PWM i.p. at various intervals prior to the 99m Tc-HAS administration. Imaging and biodistribution studies were performed at various intervals up to 2 h post- 99m Tc-HSA injection. A 32-59% increase in the tumor-to-muscle ratio was observed in the PWM-treated animals relative to the non-treated controls. To further investigate the PWM-induced tissue clearance alteration hypothesis, tissue clearance studies using 99m Tc-diethylenetriaminepentaacetic acid (DTPA) were conducted in non-tumor bearing ICR mice and the B-16/C57BL/6 tumor bearing animals. 99m Tc-DTPA normal tissue clearance rates were significantly increased in the PWM treated animals relative to the non-treated controls. (author)

  19. The model of illumination-transillumination for image enhancement of X-ray images

    Energy Technology Data Exchange (ETDEWEB)

    Lyu, Kwang Yeul [Shingu College, Sungnam (Korea, Republic of); Rhee, Sang Min [Kangwon National Univ., Chuncheon (Korea, Republic of)

    2001-06-01

    In digital image processing, the homomorphic filtering approach is derived from an illumination - reflectance model of the image. It can also be used with an illumination-transillumination model X-ray film. Several X-ray images were applied to enhancement with histogram equalization and homomorphic filter based on an illumination-transillumination model. The homomorphic filter has proven theoretical claim of image density range compression and balanced contrast enhancement, and also was found a valuable tool to process analog X-ray images to digital images.

  20. A job-related self-image enhancement programme

    OpenAIRE

    2012-01-01

    D.Litt. et Phil. This research focuses on self-concept improvement for adults. A self-image enhancement programme has been developed and its impact tested with regard to shortand medium term developments. Various training approaches have been compared to establish whether massed or spaced sessions training is more effective, and whether individual follow-up after the programme is of advantage. Self-image enhancement is seen as central to a person's functioning and psychological well-being....

  1. A developed unsharp masking method for images contrast enhancement

    International Nuclear Information System (INIS)

    Zaafouri, A.; Sayadi, M.; Fnaiech, F.

    2011-01-01

    In this paper, we propose a developed unsharp masking process for contrast image enhancement. The main idea here is to enhance the dark and bright area in the same way which matches the response of human visual system well. Then in order to reduce the noise effect, a mean weighted high pass filter is used for edge extraction. The proposed method gives satisfactory results for wide range of low contrast images compared with others known approaches.

  2. A Novel Contrast Enhancement Technique on Palm Bone Images

    Directory of Open Access Journals (Sweden)

    Yung-Tsang Chang

    2014-09-01

    Full Text Available Contrast enhancement plays a fundamental role in image processing. Many histogram-based techniques are widely used for contrast enhancement of given images, due to their simple function and effectiveness. However, the conventional histogram equalization (HE methods result in excessive contrast enhancement, which causes natural looking and satisfactory results for a variety of low contrast images. To solve such problems, a novel multi-histogram equalization technique is proposed to enhance the contrast of the palm bone X-ray radiographs in this paper. For images, the mean-variance analysis method is employed to partition the histogram of the original grey scale image into multiple sub-histograms. These histograms are independently equalized. By using this mean-variance partition method, a proposed multi-histogram equalization technique is employed to achieve the contrast enhancement of the palm bone X-ray radiographs. Experimental results show that the multi-histogram equalization technique achieves a lower average absolute mean brightness error (AMBE value. The multi-histogram equalization technique simultaneously preserved the mean brightness and enhanced the local contrast of the original image.

  3. Theory and Application of Image Enhancement

    Science.gov (United States)

    1994-02-01

    for collecting RGB data and displaying image 11205 beadbits - 0: updown m 0 11210 rowx - 3: columnx m 22: vidthlx - 58: depthx - 6: forex - 15: backx...1 11220 VIEW PRINT 2 TO 24 11230 CALL box(rowx, columnx, widthlx, depthx, forex , backx) 11240 LOCATE rowx + 1, columnx + 1: INPUT ’Type Image...Filename " f$ 11242 IF f$ - " THEN forex - 0: backx - 0 11244 IF £0 - " THEN CALL box(rowx, columnx, widthlx, depthx, forex , backx) 11246 IF f$ - THEN

  4. Image enhancement software for underwater recovery operations: User's manual

    Science.gov (United States)

    Partridge, William J.; Therrien, Charles W.

    1989-06-01

    This report describes software for performing image enhancement on live or recorded video images. The software was developed for operational use during underwater recovery operations at the Naval Undersea Warfare Engineering Station. The image processing is performed on an IBM-PC/AT compatible computer equipped with hardware to digitize and display video images. The software provides the capability to provide contrast enhancement and other similar functions in real time through hardware lookup tables, to automatically perform histogram equalization, to capture one or more frames and average them or apply one of several different processing algorithms to a captured frame. The report is in the form of a user manual for the software and includes guided tutorial and reference sections. A Digital Image Processing Primer in the appendix serves to explain the principle concepts that are used in the image processing.

  5. Image Processing for Binarization Enhancement via Fuzzy Reasoning

    Science.gov (United States)

    Dominguez, Jesus A. (Inventor)

    2009-01-01

    A technique for enhancing a gray-scale image to improve conversions of the image to binary employs fuzzy reasoning. In the technique, pixels in the image are analyzed by comparing the pixel's gray scale value, which is indicative of its relative brightness, to the values of pixels immediately surrounding the selected pixel. The degree to which each pixel in the image differs in value from the values of surrounding pixels is employed as the variable in a fuzzy reasoning-based analysis that determines an appropriate amount by which the selected pixel's value should be adjusted to reduce vagueness and ambiguity in the image and improve retention of information during binarization of the enhanced gray-scale image.

  6. Low-Light Image Enhancement Using Adaptive Digital Pixel Binning

    Directory of Open Access Journals (Sweden)

    Yoonjong Yoo

    2015-06-01

    Full Text Available This paper presents an image enhancement algorithm for low-light scenes in an environment with insufficient illumination. Simple amplification of intensity exhibits various undesired artifacts: noise amplification, intensity saturation, and loss of resolution. In order to enhance low-light images without undesired artifacts, a novel digital binning algorithm is proposed that considers brightness, context, noise level, and anti-saturation of a local region in the image. The proposed algorithm does not require any modification of the image sensor or additional frame-memory; it needs only two line-memories in the image signal processor (ISP. Since the proposed algorithm does not use an iterative computation, it can be easily embedded in an existing digital camera ISP pipeline containing a high-resolution image sensor.

  7. HDR Image Quality Enhancement Based on Spatially Variant Retinal Response

    Directory of Open Access Journals (Sweden)

    Horiuchi Takahiko

    2010-01-01

    Full Text Available There is a growing demand for being able to display high dynamic range (HDR images on low dynamic range (LDR devices. Tone mapping is a process for enhancing HDR image quality on an LDR device by converting the tonal values of the original image from HDR to LDR. This paper proposes a new tone mapping algorithm for enhancing image quality by deriving a spatially-variant operator for imitating S-potential response in human retina, which efficiently improves local contrasts while conserving good global appearance. The proposed tone mapping operator is studied from a system construction point of view. It is found that the operator is regarded as a natural extension of the Retinex algorithm by adding a global adaptation process to the local adaptation. The feasibility of the proposed algorithm is examined in detail on experiments using standard HDR images and real HDR scene images, comparing with conventional tone mapping algorithms.

  8. Enhanced refractor imaging by supervirtual interferometry

    KAUST Repository

    Mallinson, Ian

    2011-05-01

    Refraction surveys are a well-established method of imaging subsurface velocities, both in terms of the deep crustal structure at global scales and in the shallow near surface. These surveys generally involve deploying an array of receivers on the surface (or water bottom) and recording arrivals from a seismic source initiated at or near the surface.

  9. Automated image enhancement using power law transformations

    Indian Academy of Sciences (India)

    1Birla Institute of Technology & Science (BITS), Pilani 333 031, India .... Our algorithm has the advantage that it is very simple to implement and .... Education. Jun J, Jun C and Xinglin C 2008 CISP, vol. 3, Congress on Image and Signal ...

  10. Lesion Contrast Enhancement in Medical Ultrasound Imaging

    DEFF Research Database (Denmark)

    Stetson, Paul F.; Sommer, F.G.; Macovski, A.

    1997-01-01

    Methods for improving the contrast-to-noise ratio (CNR) of low-contrast lesions in medical ultrasound imaging are described. Differences in the frequency spectra and amplitude distributions of the lesion and its surroundings can be used to increase the CNR of the lesion relative to the background...

  11. An enhanced approach for biomedical image restoration using image fusion techniques

    Science.gov (United States)

    Karam, Ghada Sabah; Abbas, Fatma Ismail; Abood, Ziad M.; Kadhim, Kadhim K.; Karam, Nada S.

    2018-05-01

    Biomedical image is generally noisy and little blur due to the physical mechanisms of the acquisition process, so one of the common degradations in biomedical image is their noise and poor contrast. The idea of biomedical image enhancement is to improve the quality of the image for early diagnosis. In this paper we are using Wavelet Transformation to remove the Gaussian noise from biomedical images: Positron Emission Tomography (PET) image and Radiography (Radio) image, in different color spaces (RGB, HSV, YCbCr), and we perform the fusion of the denoised images resulting from the above denoising techniques using add image method. Then some quantive performance metrics such as signal -to -noise ratio (SNR), peak signal-to-noise ratio (PSNR), and Mean Square Error (MSE), etc. are computed. Since this statistical measurement helps in the assessment of fidelity and image quality. The results showed that our approach can be applied of Image types of color spaces for biomedical images.

  12. Teaching People and Machines to Enhance Images

    Science.gov (United States)

    Berthouzoz, Floraine Sara Martianne

    Procedural tasks such as following a recipe or editing an image are very common. They require a person to execute a sequence of operations (e.g. chop onions, or sharpen the image) in order to achieve the goal of the task. People commonly use step-by-step tutorials to learn these tasks. We focus on software tutorials, more specifically photo manipulation tutorials, and present a set of tools and techniques to help people learn, compare and automate photo manipulation procedures. We describe three different systems that are each designed to help with a different stage in acquiring procedural knowledge. Today, people primarily rely on hand-crafted tutorials in books and on websites to learn photo manipulation procedures. However, putting together a high quality step-by-step tutorial is a time-consuming process. As a consequence, many online tutorials are poorly designed which can lead to confusion and slow down the learning process. We present a demonstration-based system for automatically generating succinct step-by-step visual tutorials of photo manipulations. An author first demonstrates the manipulation using an instrumented version of GIMP (GNU Image Manipulation Program) that records all changes in interface and application state. From the example recording, our system automatically generates tutorials that illustrate the manipulation using images, text, and annotations. It leverages automated image labeling (recognition of facial features and outdoor scene structures in our implementation) to generate more precise text descriptions of many of the steps in the tutorials. A user study finds that our tutorials are effective for learning the steps of a procedure; users are 20-44% faster and make 60-95% fewer errors when using our tutorials than when using screencapture video tutorials or hand-designed tutorials. We also demonstrate a new interface that allows learners to navigate, explore and compare large collections (i.e. thousands) of photo manipulation

  13. Color Histogram Diffusion for Image Enhancement

    Science.gov (United States)

    Kim, Taemin

    2011-01-01

    Various color histogram equalization (CHE) methods have been proposed to extend grayscale histogram equalization (GHE) for color images. In this paper a new method called histogram diffusion that extends the GHE method to arbitrary dimensions is proposed. Ranges in a histogram are specified as overlapping bars of uniform heights and variable widths which are proportional to their frequencies. This diagram is called the vistogram. As an alternative approach to GHE, the squared error of the vistogram from the uniform distribution is minimized. Each bar in the vistogram is approximated by a Gaussian function. Gaussian particles in the vistoram diffuse as a nonlinear autonomous system of ordinary differential equations. CHE results of color images showed that the approach is effective.

  14. Hepatocellular carcinoma. Comparison between gadolinium and ironoxide enhanced MR imaging

    International Nuclear Information System (INIS)

    Castoldi, M.C.; Fauda, V.; Scaramuzza, D.; Vergnaghi, D.

    2000-01-01

    Purpose of this work is to compare prospectively dynamic gadolinium (Gd)-enhanced with superparamagnetic iron oxide (SPIO)-enhanced MRI for the detection of hepatocellular carcinoma (HCC). Twenty-five patients with histologically proven HCC and liver cirrhosis (28% of them in B or C Child class) underwent dynamic Gd-enhanced MRI and, a few days later, (mean interval: three days) SPIO-enhanced MRI. Only patients with availability of clinical and imaging follow-up for at least seven months were enrolled in this prospective study. MR images were reviewed by two independent radiologists. The readers scored each lesion for the presence of HCC and assigned confidence levels based on a five-grade scale: 1, definitely or almost definitely absent; 2, possibly present; 3, probably present; 4, definitely present; 5, definitely present with optimal liver/lesion contrast or good liver/lesion contrast and morphological signs (intact capsule, intranodular septa, extracapsular infiltration), useful for locoregional treatment planning. A positive diagnostic value was assessed for scores of 3 or higher. Gd-enhanced and SPIO-enhanced MRI found 44 lesions. Eight of twelve lesions visible with a single contrast agent measured less than 1 cm in diameter. HCC detectability was 75% with Gd-enhanced MRI and 97.7% with SPIO-enhanced MRI. SPIO-enhanced T2-weighted TSE images showed significantly higher diagnostic value than SPIO-enhanced T1-T2*GRE images only in three cases, while nodule morphological characteristics (capsule, septa, different cell differentiation components) were better depicted by TSE images. In thi study the combined use of SPIO-enhanced T2-weighted TSE and T1-T2*-weighted GRE sequences showed higher sensitivity than gadolinium-enhanced GRE dynamic imaging (97.7% versus 75%). These results are at least partly related to our study conditions, that is: 1)MRI was performed with a 1T system, 2) both axial and sagittal SPIO-enhanced imaging were performed with respiratory

  15. Algorithms evaluation for fundus images enhancement

    International Nuclear Information System (INIS)

    Braem, V; Marcos, M; Bizai, G; Drozdowicz, B; Salvatelli, A

    2011-01-01

    Color images of the retina inherently involve noise and illumination artifacts. In order to improve the diagnostic quality of the images, it is desirable to homogenize the non-uniform illumination and increase contrast while preserving color characteristics. The visual result of different pre-processing techniques can be very dissimilar and it is necessary to make an objective assessment of the techniques in order to select the most suitable. In this article the performance of eight algorithms to correct the non-uniform illumination, contrast modification and color preservation was evaluated. In order to choose the most suitable a general score was proposed. The results got good impression from experts, although some differences suggest that not necessarily the best statistical quality of image is the one of best diagnostic quality to the trained doctor eye. This means that the best pre-processing algorithm for an automatic classification may be different to the most suitable one for visual diagnosis. However, both should result in the same final diagnosis.

  16. Image enhancement of optical images for binary system of melanocytes and keratinocytes

    Science.gov (United States)

    Takanezawa, S.; Baba, A.; Sako, Y.; Ozaki, Y.; Date, A.; Toyama, K.; Morita, S.

    2013-05-01

    Automatic determination of the cell shapes of large numbers of melanocytes based on optical images of human skin models have been largely unsuccessful (the complexities introduced by dendrites and the melanin pigmentation over the keratinocytes to give unclear outlines). Here, we present an image enhancement procedure for enhancing the contrast of images with removing the non-uniformity of background. The brightness is normalized also for the non-uniform population density of melanocytes.

  17. Diagnostic accuracy of the Thessaly test, standardised clinical history and other clinical examination tests (Apley's, McMurray's and joint line tenderness) for meniscal tears in comparison with magnetic resonance imaging diagnosis.

    Science.gov (United States)

    Blyth, Mark; Anthony, Iain; Francq, Bernard; Brooksbank, Katriona; Downie, Paul; Powell, Andrew; Jones, Bryn; MacLean, Angus; McConnachie, Alex; Norrie, John

    2015-08-01

    Reliable non-invasive diagnosis of meniscal tears is difficult. Magnetic resonance imaging (MRI) is often used but is expensive and incidental findings are problematic. There are a number of physical examination tests for the diagnosis of meniscal tears that are simple, cheap and non-invasive. To determine the diagnostic accuracy of the Thessaly test and to determine if the Thessaly test (alone or in combination with other physical tests) can obviate the need for further investigation by MRI or arthroscopy for patients with a suspected meniscal tear. Single-centre prospective diagnostic accuracy study. Although the study was performed in a secondary care setting, it was designed to replicate the results that would have been achieved in a primary care setting. Two cohorts of patients were recruited: patients with knee pathology (n = 292) and a control cohort with no knee pathology (n = 75). Sensitivity, specificity and diagnostic accuracy of the Thessaly test in determining the presence of meniscal tears. Participants were assessed by both a primary care clinician and a musculoskeletal clinician. Both clinicians performed the Thessaly test, McMurray's test, Apley's test, joint line tenderness test and took a standardised clinical history from the patient. The Thessaly test had a sensitivity of 0.66, a specificity of 0.39 and a diagnostic accuracy of 54% when utilised by primary care clinicians. This compared with a sensitivity of 0.62, a specificity of 0.55 and diagnostic accuracy of 59% when used by musculoskeletal clinicians. The diagnostics accuracy of the other tests when used by primary care clinicians was 54% for McMurray's test, 53% for Apley's test, 54% for the joint line tenderness test and 55% for clinical history. For primary care clinicians, age and past history of osteoarthritis were both significant predictors of MRI diagnosis of meniscal tears. For musculoskeletal clinicians age and a positive diagnosis of meniscal tears on clinical history

  18. Contrast enhanced MR imaging of postoperative medulloblastoma in childhood: emphasis on meningeal enhancement

    International Nuclear Information System (INIS)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Kim, Ho Chul; Yeon, Kyung Mo

    1993-01-01

    To differentiate the postoperative changes from the recurrence of tumor and to evaluate MR imaging of early postoperative leptomeningeal seeding in medulloblastoma, We have retrospectively analysed 34 cases of MR images of 17 patients who were confirmed as medulloblastoma by histopathology. Noncontrast and postcontrast T1 weighted MR images were obtained in all patients. In 11 patients follow-up MR was done more than once (average: 1.5 times) and average interval of MR imaging was 6 months. The timing of 34 MR images was as follow: 6 case within 2 months, 9 cases between 2 months and 1 year, 19 cases more than 1 year after surgery respectively. MR images within 2 month after surgery revealed contrast enhancement at operation site and adjacent meninges, hemorrhage, residual tumor. In patients who had no evidence of tumor recurrence, these early postoperative changes were markedly decreased within 6 month after surgery. MR images obtained more than 1 year after surgery showed no abnormal contrast enhancement or mild focal dural enhancement at operation site. Diffuse moderate dural enhancement was noted in one patient who had the history of post-surgical subdural hemorrhage. In six patients with tumor recurrences which were detected from as early as 9 months to 6 years after surgery, the findings of recurrence included leptomeningeal enhancement of brain stem and cerebellar surface at early stage, variable sized enhancing leptomeningeal nodules, linear or irregular sulcus obliterating enhancing lesions, enhancing mass at primary or metastatic site. We have concluded that leptomeningeal enhancement detected after 6 months of surgery is an important MR finding suggesting the possibility of tumor recurrence. Small nodular and linear enhancement of leptomeninges at brainstem or cerebellar surface is considered as the early manifestation of intracranial tumor seeding

  19. Contrast enhanced MR imaging of postoperative medulloblastoma in childhood: emphasis on meningeal enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Kim, Ho Chul; Yeon, Kyung Mo [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1993-03-15

    To differentiate the postoperative changes from the recurrence of tumor and to evaluate MR imaging of early postoperative leptomeningeal seeding in medulloblastoma, We have retrospectively analysed 34 cases of MR images of 17 patients who were confirmed as medulloblastoma by histopathology. Noncontrast and postcontrast T1 weighted MR images were obtained in all patients. In 11 patients follow-up MR was done more than once (average: 1.5 times) and average interval of MR imaging was 6 months. The timing of 34 MR images was as follow: 6 case within 2 months, 9 cases between 2 months and 1 year, 19 cases more than 1 year after surgery respectively. MR images within 2 month after surgery revealed contrast enhancement at operation site and adjacent meninges, hemorrhage, residual tumor. In patients who had no evidence of tumor recurrence, these early postoperative changes were markedly decreased within 6 month after surgery. MR images obtained more than 1 year after surgery showed no abnormal contrast enhancement or mild focal dural enhancement at operation site. Diffuse moderate dural enhancement was noted in one patient who had the history of post-surgical subdural hemorrhage. In six patients with tumor recurrences which were detected from as early as 9 months to 6 years after surgery, the findings of recurrence included leptomeningeal enhancement of brain stem and cerebellar surface at early stage, variable sized enhancing leptomeningeal nodules, linear or irregular sulcus obliterating enhancing lesions, enhancing mass at primary or metastatic site. We have concluded that leptomeningeal enhancement detected after 6 months of surgery is an important MR finding suggesting the possibility of tumor recurrence. Small nodular and linear enhancement of leptomeninges at brainstem or cerebellar surface is considered as the early manifestation of intracranial tumor seeding.

  20. Ghost image in enhanced self-heterodyne synthetic aperture imaging ladar

    Science.gov (United States)

    Zhang, Guo; Sun, Jianfeng; Zhou, Yu; Lu, Zhiyong; Li, Guangyuan; Xu, Mengmeng; Zhang, Bo; Lao, Chenzhe; He, Hongyu

    2018-03-01

    The enhanced self-heterodyne synthetic aperture imaging ladar (SAIL) self-heterodynes two polarization-orthogonal echo signals to eliminate the phase disturbance caused by atmospheric turbulence and mechanical trembling, uses heterodyne receiver instead of self-heterodyne receiver to improve signal-to-noise ratio. The principle and structure of the enhanced self-heterodyne SAIL are presented. The imaging process of enhanced self-heterodyne SAIL for distributed target is also analyzed. In enhanced self-heterodyne SAIL, the phases of two orthogonal-polarization beams are modulated by four cylindrical lenses in transmitter to improve resolutions in orthogonal direction and travel direction, which will generate ghost image. The generation process of ghost image in enhanced self-heterodyne SAIL is mathematically detailed, and a method of eliminating ghost image is also presented, which is significant for far-distance imaging. A number of experiments of enhanced self-heterodyne SAIL for distributed target are presented, these experimental results verify the theoretical analysis of enhanced self-heterodyne SAIL. The enhanced self-heterodyne SAIL has the capability to eliminate the influence from the atmospheric turbulence and mechanical trembling, has high advantage in detecting weak signals, and has promising application for far-distance ladar imaging.

  1. Evaluation of the intraspinal enhancement for medulloblastoma on MR imaging

    International Nuclear Information System (INIS)

    Kim, Hwa Young; Kim, In One; Kim, Woo Sun; Cheon, Jung Eun; Yeon, Kyung Mo

    2004-01-01

    The purpose of this study was to analyze the enhancement pattern of the spinal cord for patients with medulloblastoma, and to correlate the enhancement pattern with cerebrospinal fluid (CSF) tumor seeding. We retrospectively reviewed 84 MR images, including the initial and follow-up studies after chemotherapy or radiation therapy, of 25 patients with medulloblastoma who were aged from 2 to 13 years. We analyzed the spinal leptomeningeal enhancement pattern on the MR images. The leptomeningeal enhancement patterns were categorized into three types: Type, I, fine or discontinuous linear enhancement, and type II, continuous linear or nodular enhancement, and type III, intradural mass formation. We correlated the enhancement pattern on MRI with the results of CSF cytology at the initial and follow-up examinations after treatment. Of total 25 patients, type I enhancement was observed for 14 patients. Twelve patients were negative on the initial CSF cytology and 2 patients were positive. On the follow-up MR studies, 14 patients showed no change or only a slight decrease of enhancement, and all were negative on the follow-up CSF cytology. Type II enhancement patterns were observed in seven patients, and all of them were positive on the initial CSF cytology. On follow-up MR study, one patient revealed an increased enhancement with the positive result on the follow-up CSF cytology, and six patients had decreased enhancement on the follow-up MR studies with negative conversion on the follow-up CSF cytology. Type III enhancement patterns were observed in four patients and all of them were positive on the initial CSF cytology. All four patients with tradural mass formations revealed progression of the lesions on follow-up MR studies, and all of them were positive on the follow-up CSF cytology. Type II and III enhancement patterns always represented CSF seeding and a type I enhancement pattern had a low probability of metastasis

  2. FUZZY BASED CONTRAST STRETCHING FOR MEDICAL IMAGE ENHANCEMENT

    Directory of Open Access Journals (Sweden)

    T.C. Raja Kumar

    2011-07-01

    Full Text Available Contrast Stretching is an important part in medical image processing applications. Contrast is the difference between two adjacent pixels. Fuzzy statistical values are analyzed and better results are produced in the spatial domain of the input image. The histogram mapping produces the resultant image with less impulsive noise and smooth nature. The probabilities of gray values are generated and the fuzzy set is determined from the position of the input image pixel. The result indicates the good performance of the proposed fuzzy based stretching. The inverse transform of the real values are mapped with the input image to generate the fuzzy statistics. This approach gives a flexible image enhancement for medical images in the presence of noises.

  3. Gd-DTPA MR imaging enhancement of spinal cord tumors

    International Nuclear Information System (INIS)

    Dillon, W.P.; Bolla, K.; Mark, A.S.; Tsudura, J.S.; Norman, D.; Newton, T.H.

    1987-01-01

    Nineteen patients with suspected spinal cord tumors were imaged with T1- and T2-weighted sequences before and after the administration of Gd-DTPA (0.1 mmol/kg). Eleven of the 19 patients had spinal cord tumors (three unproven). Eight of 11 patients had intramedullary tumors (four astrocytomas, two ependymomas) and two had extra-medullary tumors (one meningioma, one metastatic melanoma). Other lesions studied include idiopathic syringomyelia (two), spinal arteriovenous malformation (AVM) (one), posttraumatic arachnoiditis (one), and cord infarct (one). All of the tumors enhanced after the administration of Gd-DTPA. Spinal cord enhancement was also noted in association with a spinal cord AVM, a suspected cord infarct, and in the patient with severe arachnoiditis. No enhancement was present in patients with idiopathic or posttraumatic syringomyelia or in the three normal patients. In six of the patients, enhancement was critical in confirming disease that was questionable on the precontrast MR images. Gadolinium enhancement allowed differentiation of tumor from postoperative changes in two patients with spinal cord tumors. Enhanced images localized the lesion more accurately than precontrast MR images in eight patients. In four patients a lesion could only be detected after the administration of contrast. The postcontrast images better defined the margin of tumor from surrounding edema, operative scarring, and cord cavitation. The AVM case had enhancement of slowly flowing veins with Gd-DTPA posterior to an ischemic cord segment. Gd-DTPA enhancement is extremely useful in the detection and therapeutic assessment of spinal cord tumors; however, enhancement is not specific for tumors and should be interpreted in light of the clinical setting

  4. Parallel imaging enhanced MR colonography using a phantom model.

    LENUS (Irish Health Repository)

    Morrin, Martina M

    2008-09-01

    To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)-enhanced T2W SSFSE (single shot fast spin echo) and T1-weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath-hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET-enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution.

  5. Enhancing global positioning by image recognition

    OpenAIRE

    Marimon Sanjuan, David; Adamek, Tomasz; Bonnin, Arturo; Trzcinski, Tomasz

    2011-01-01

    Current commercial outdoor Mobile AR applications rely mostly on GPS antennas, digital compasses and accelerometers. Due to imprecise readings, the 2D placement of points of interest (POI) on the display can be uncorrelated with reality. We present a novel method to geo-locate a mobile device by rec- ognizing what is captured by its camera. A visual recognition algo- rithm in the cloud is used to identify geo-located reference images that match the camera’s view. Upon correct identification, ...

  6. Evaluation of carotid vessel wall enhancement with image subtraction after gadobenate dimeglumine-enhanced MR angiography

    International Nuclear Information System (INIS)

    Sardanelli, Francesco; Di Leo, Giovanni; Aliprandi, Alberto; Flor, Nicola; Papini, Giacomo D.E.; Roccatagliata, Luca; Cotticelli, Biagio; Nano, Giovanni; Cornalba, Gianpaolo

    2009-01-01

    Objectives: This study was aimed at testing the value of image subtraction for evaluating carotid vessel wall enhancement in contrast-enhanced MR angiography (MRA). Materials and methods: IRB approval was obtained. The scans of 81 consecutive patients who underwent carotid MRA with 0.1 mmol/kg of gadobenate dimeglumine were reviewed. Axial carotid 3D T1-weighted fast low-angle shot sequence before and 3 min after contrast injection were acquired and subtracted (enhanced minus unenhanced). Vessel wall enhancement was assigned a four-point score using native or subtracted images from 0 (no enhancement) to 3 (strong enhancement). Stenosis degree was graded according to NASCET. Results: With native images, vessel wall enhancement was detected in 20/81 patients (25%) and in 20/161 carotids (12%), and scored 2.0 ± 0.6 (mean ± standard deviation); with subtracted images, in 21/81 (26%) and 22/161 (14%), and scored 2.5 ± 0.6, respectively (P < 0.001, Sign test). The overall stenosis degree distribution was: mild, 41/161 (25%); moderate, 77/161 (48%); severe, 43/161 (27%). Carotids with moderate stenosis showed vessel wall enhancement with a frequency (17/77, 22%) significantly higher than that observed in carotids with mild stenosis (1/41, 2%) (P = 0.005, Fisher exact test) and higher, even though with borderline significance (P = 0.078, Fisher exact test), than that observed in carotids with severe stenosis (4/43, 9%). Conclusion: Roughly a quarter of patients undergoing carotid MRA showed vessel wall enhancement. Image subtraction improved vessel wall enhancement conspicuity. Vessel wall enhancement seems to be an event relatively independent from the degree of stenosis. Further studies are warranted to define the relation between vessel wall enhancement and histopathology, inflammatory status, and instability.

  7. Double Minimum Variance Beamforming Method to Enhance Photoacoustic Imaging

    OpenAIRE

    Paridar, Roya; Mozaffarzadeh, Moein; Nasiriavanaki, Mohammadreza; Orooji, Mahdi

    2018-01-01

    One of the common algorithms used to reconstruct photoacoustic (PA) images is the non-adaptive Delay-and-Sum (DAS) beamformer. However, the quality of the reconstructed PA images obtained by DAS is not satisfying due to its high level of sidelobes and wide mainlobe. In contrast, adaptive beamformers, such as minimum variance (MV), result in an improved image compared to DAS. In this paper, a novel beamforming method, called Double MV (D-MV) is proposed to enhance the image quality compared to...

  8. Diffraction enhanced imaging of normal and arthritic mice feet

    International Nuclear Information System (INIS)

    Crittell, Suzanne; Cheung, K.C.; Hall, Chris; Ibison, Mark; Nolan, Paul; Page, Robert; Scraggs, David; Wilkinson, Steve

    2007-01-01

    The aim of this experiment was to produce X-ray images of mice feet using the diffraction-enhanced imaging (DEI) system at the UK Synchrotron Radiation Source (SRS) at Daresbury. There were two broad types of mice feet samples studied: normal and arthritic. The two types of samples were imaged using several views and compared in order to determine whether it would be possible to detect the early morphological changes linked with this form of arthritis. We found that the DEI images produced were indeed of sufficient quality to show the presence of some osteoarthritic changes

  9. Fundamentals of quantitative dynamic contrast-enhanced MR imaging.

    Science.gov (United States)

    Paldino, Michael J; Barboriak, Daniel P

    2009-05-01

    Quantitative analysis of dynamic contrast-enhanced MR imaging (DCE-MR imaging) has the power to provide information regarding physiologic characteristics of the microvasculature and is, therefore, of great potential value to the practice of oncology. In particular, these techniques could have a significant impact on the development of novel anticancer therapies as a promising biomarker of drug activity. Standardization of DCE-MR imaging acquisition and analysis to provide more reproducible measures of tumor vessel physiology is of crucial importance to realize this potential. The purpose of this article is to review the pathophysiologic basis and technical aspects of DCE-MR imaging techniques.

  10. Real-time movie image enhancement in NMR

    International Nuclear Information System (INIS)

    Doyle, M.; Mansfield, P.

    1986-01-01

    Clinical NMR motion picture (movie) images can now be produced routinely in real-time by ultra-high-speed echo-planar imaging (EPI). The single-shot image quality depends on both pixel resolution and signal-to-noise ratio (S/N), both factors being intertradeable. If image S/N is sacrificed rather than resolution, it is shown that S/N may be greatly enhanced subsequently without vitiating spatial resolution or foregoing real motional effects when the object motion is periodic. This is achieved by a Fourier filtering process. Experimental results are presented which demonstrate the technique for a normal functioning heart. (author)

  11. Contrast-enhanced CISS imaging of cerebellopontine angle tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Toyoda, Keiko; Hata, Yuichi; Fukuda, Yasushi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Katano, Shuichi

    1999-10-01

    Our purpose of this study was to evaluate the clinical usefulness of contrast-enhanced CISS-3DFT MR imaging for the diagnosis of CP angle tumors. CISS-3DFT MR imaging is expected for screening procedure of acoustic schwannoma because of excellent spatial resolution. Recently, we discovered contrast enhancement effect on CISS sequence in spite of heavily T{sub 2}-weighted images. Fourteen patients with CP angle tumors were performed on a 1.0 T MR unit. Transaxial CISS-3DFT MRI was obtained both before and after intravenous injections of Gd-DTPA. Multiplanar reconstructions (MPRs) were performed in all cases. Contrast enhancement effect of CP angle tumors, and the relationship between tumors and the adjacent cranial nerves were evaluated. Contrast enhancement effect of the tumors was present in all cases in spite of heavily T{sub 2}-weighted images of CISS sequences. In the internal auditory canal, relationship between the tumors and the cranial nerves was demonstrated in 6 cases (6/9). In the cerebellopontine cistern, all cases were demonstrated (11/11). Contrast-enhanced CISS-3DFT MR imaging with a good contrast resolution and an excellent spatial resolution is useful for the diagnosis of CP angle tumors. (author)

  12. Gd-EOB-DTPA-enhanced magnetic resonance imaging features of hepatic hemangioma compared with enhanced computed tomography

    OpenAIRE

    Tateyama, Akihiro; Fukukura, Yoshihiko; Takumi, Koji; Shindo, Toshikazu; Kumagae, Yuichi; Kamimura, Kiyohisa; Nakajo, Masayuki

    2012-01-01

    AIM: To clarify features of hepatic hemangiomas on gadolinium-ethoxybenzyl-diethylenetriaminpentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) compared with enhanced computed tomography (CT).

  13. Evaluation of Underwater Image Enhancement Algorithms under Different Environmental Conditions

    Directory of Open Access Journals (Sweden)

    Marino Mangeruga

    2018-01-01

    Full Text Available Underwater images usually suffer from poor visibility, lack of contrast and colour casting, mainly due to light absorption and scattering. In literature, there are many algorithms aimed to enhance the quality of underwater images through different approaches. Our purpose was to identify an algorithm that performs well in different environmental conditions. We have selected some algorithms from the state of the art and we have employed them to enhance a dataset of images produced in various underwater sites, representing different environmental and illumination conditions. These enhanced images have been evaluated through some quantitative metrics. By analysing the results of these metrics, we tried to understand which of the selected algorithms performed better than the others. Another purpose of our research was to establish if a quantitative metric was enough to judge the behaviour of an underwater image enhancement algorithm. We aim to demonstrate that, even if the metrics can provide an indicative estimation of image quality, they could lead to inconsistent or erroneous evaluations.

  14. Hepatocellular carcinoma on MR diffusion weighted imaging and dynamic contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Dong Aisheng; Zuo Changjing; Tian Jianming; Lu Jianping; Wang Jian; Wang Li; Wang Fei

    2009-01-01

    Objective: To evaluate the findings of hepatocellular carcinoma (HCC) on DWI and dynamic Gd-DTPA-enhanced MR imaging. Methods: Eighty one patients with chronic hepatitis or liver cirrhosis underwent both DWI and dynamic Gd-DTPA-enhanced MRI studies of the liver for HCC detection. MR data of were retrospectively analyzed. Two observers determined in consensus the location and the number of focal lesions. The signal manifestation of the lesions on DWI and dynamic Gd-DTPA-enhanced MR imaging were analyzed. Results: DWI and Gd-DTPA-enhanced MR images detected 122 HCCs and 14 benign lesions. One hundred and sixteen HCCs (95.1%) showed hyperintensity on DWI and 6 HCCs in patients with severe cirrhosis showed isointensity. One hundred and five HCCs (86.1%) revealed hypointensity, 11 HCCs (9.0%) showed isointensity and 6 HCCs (4.9%) exhibited hyperintensity on T 1 weighted images. On Gd-DTPA-enhanced MR images, 101 HCCs(82.8%) were significantly enhanced on arterial phase and 99 HCCs showed hypointensity on portal and equilibrium phases. Twenty HCCs (16.4%), 18 of 20 less than 20 mm in diameter, showed isointensity on arterial phase and hyperintensity on DWI. Eight of 14 benign lesions showed hyperintensity and 6 isointensity on DWI. Five benign lesions with hypointensity on T 1 weighted images without contrast and hyperintensity on DWI showed no enhancement on Gd-DTPA-enhanced MR images; 6 benign lesions with isointensity on both T 1 weighted imaging without contrast and DWI exhibited avid enhancement on arterial phase and isointensty on portal and equilibrium phases; one of the two benign lesions, with isointensity before and after contrast images and hyperintentiy on DWI, was a regenerative nodule; another regenerative nodule with hyperintensity on both T 1 weighted images without contrast and DWI was greatly enhanced on arterial phase and showed isointensity on portal and equilibrium phases. Conclusions: Most of the HCCs were greatly enhanced on arterial phase on Gd-DTPA-enhanced

  15. Enhancement and denoising of mammographic images for breast disease detection

    International Nuclear Information System (INIS)

    Yazdani, S.; Yusof, R.; Karimian, A.; Hematian, A.; Yousefi, M.

    2012-01-01

    In these two decades breast cancer is one of the leading cause of death among women. In breast cancer research, Mammographic Image is being assessed as a potential tool for detecting breast disease and investigating response to chemotherapy. In first stage of breast disease discovery, the density measurement of the breast in mammographic images provides very useful information. Because of the importance of the role of mammographic images the need for accurate and robust automated image enhancement techniques is becoming clear. Mammographic images have some disadvantages such as, the high dependence of contrast upon the way the image is acquired, weak distinction in splitting cyst from tumor, intensity non uniformity, the existence of noise, etc. These limitations make problem to detect the typical signs such as masses and microcalcifications. For this reason, denoising and enhancing the quality of mammographic images is very important. The method which is used in this paper is in spatial domain which its input includes high, intermediate and even very low contrast mammographic images based on specialist physician's view, while its output is processed images that show the input images with higher quality, more contrast and more details. In this research, 38 mammographic images have been used. The result of purposed method shows details of abnormal zones and the areas with defects so that specialist could explore these zones more accurately and it could be deemed as an index for cancer diagnosis. In this study, mammographic images are initially converted into digital images and then to increase spatial resolution power, their noise is reduced and consequently their contrast is improved. The results demonstrate effectiveness and efficiency of the proposed methods. (authors)

  16. Diffraction-enhanced imaging of the rat spine

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, M.E. [Cleveland Clinic, Dept. of Neurosurgery, Cleveland, Ohio (United States)]. E-mail: mebkelly@gmail.com; Beavis, R.C. [Univ. of Saskatchewan, Royal Univ. Hospital, Div. of Orthopaedic Surgery, Saskatoon, Saskatchewan (Canada); Fourney, D.R. [Univ. of Saskatchewan, Royal Univ. Hospital, Div. of Neurosurgery, Saskatoon, Saskatchewan (Canada); Schultke, E. [Univ. of Saskatchewan, Dept. of Anatomy and Cell Biology, Saskatoon, Saskatchewan (Canada); Parham, C. [Univ. of North Carolina, Dept. of Biomedical Engineering, Chapel Hill, North Carolina (United States); Juurlink, B.H. [Univ. of Saskatchewan, Dept. of Anatomy and Cell Biology, Saskatoon, Saskatchewan (Canada); Zhong, Z. [Brookhaven National Laboratory, National Synchrotron Light Source, Upton, New York (United States); Chapman, L.D. [Univ. of Saskatchewan, Dept. of Anatomy and Cell Biology, Saskatoon, Saskatchewan (Canada)

    2006-10-15

    Diffraction-enhanced imaging (DEI) uses monochromatic synchrotron X-rays to image tissue. This technique has been shown to produce superior bony and soft tissue characterization when compared with conventional absorption radiography. Application of this imaging modality is under investigation, and this study represents the first DEI analysis of the vertebral column. Four male Wistar rats were studied. Spine muscle blocks were imaged in 3 of the rats after thoracic laminectomy (n = 1), after lumbar laminectomy (n = 1), and in a control condition (n = 1). The fourth rat was imaged as a whole animal control. Conventional radiography and synchrotron-supported DEI at 40 keV were performed on all specimens. We compared images side by side, using a nonvalidated subjective assessment technique. DEI produced superior visualization of the vertebral anatomy, compared with conventional absorption radiography for all specimens. Greater bony and soft tissue detail was noted, with improved image contrast. In addition to imaging the anatomical structures, DEI showed the polyglactin suture material used for fascial closure in the 2 animals that underwent surgery. Artifact from air bubbles was present on DEI images but not on plain radiographs. This represents the first use of DEI, a novel imaging modality, to image the vertebral column. It provides excellent anatomic detail with superior contrast and visualization of both bone and soft tissue when compared with conventional radiography. Future applications of this investigational technique may include analysis of spinal fusion as well as degenerative and neoplastic conditions of the spine. (author)

  17. Diffraction-enhanced imaging of the rat spine

    International Nuclear Information System (INIS)

    Kelly, M.E.; Beavis, R.C.; Fourney, D.R.; Schultke, E.; Parham, C.; Juurlink, B.H.; Zhong, Z.; Chapman, L.D.

    2006-01-01

    Diffraction-enhanced imaging (DEI) uses monochromatic synchrotron X-rays to image tissue. This technique has been shown to produce superior bony and soft tissue characterization when compared with conventional absorption radiography. Application of this imaging modality is under investigation, and this study represents the first DEI analysis of the vertebral column. Four male Wistar rats were studied. Spine muscle blocks were imaged in 3 of the rats after thoracic laminectomy (n = 1), after lumbar laminectomy (n = 1), and in a control condition (n = 1). The fourth rat was imaged as a whole animal control. Conventional radiography and synchrotron-supported DEI at 40 keV were performed on all specimens. We compared images side by side, using a nonvalidated subjective assessment technique. DEI produced superior visualization of the vertebral anatomy, compared with conventional absorption radiography for all specimens. Greater bony and soft tissue detail was noted, with improved image contrast. In addition to imaging the anatomical structures, DEI showed the polyglactin suture material used for fascial closure in the 2 animals that underwent surgery. Artifact from air bubbles was present on DEI images but not on plain radiographs. This represents the first use of DEI, a novel imaging modality, to image the vertebral column. It provides excellent anatomic detail with superior contrast and visualization of both bone and soft tissue when compared with conventional radiography. Future applications of this investigational technique may include analysis of spinal fusion as well as degenerative and neoplastic conditions of the spine. (author)

  18. Experimental and theoretical investigations of diffraction enhanced imaging

    International Nuclear Information System (INIS)

    Wang Junyue; Zhu Peiping; Yuan Qingxi; Huang Wanxia; Shu Hang; Chen Bo; Li Enrong; Liu Yijin; Hu Tiandou; Wu Ziyu

    2007-01-01

    This contribution investigates the effect on the imaging contrast of the small angle scattering and of the rocking curve in the entire angular range. We show that based on the small angle scattering properties, the reflectivity of the crystal analyzer and the rocking curve of the monochromator-analyzer, in a diffraction enhanced imaging (DEI) experimental setup the contrast of the image collected at the top of the rocking curve is always higher than that of the apparent absorption image. Moreover, our experimental data confirm that the quality of a refraction image is superior to a refraction-like image. In order to understand the observed behavior we introduce and discuss the contribution of a new term in the classical DEI equation

  19. Experimental and theoretical investigations of diffraction enhanced imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang Junyue [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Graduate University of the Chinese Academy of Sciences, Beijing 100049 (China); Zhu Peiping [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)], E-mail: zhupp@ihep.ac.cn; Yuan Qingxi; Huang Wanxia [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Shu Hang [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Graduate University of the Chinese Academy of Sciences, Beijing 100049 (China); Chen Bo [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Li Enrong [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Graduate University of the Chinese Academy of Sciences, Beijing 100049 (China); Liu Yijin; Hu Tiandou; Wu Ziyu [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2007-09-21

    This contribution investigates the effect on the imaging contrast of the small angle scattering and of the rocking curve in the entire angular range. We show that based on the small angle scattering properties, the reflectivity of the crystal analyzer and the rocking curve of the monochromator-analyzer, in a diffraction enhanced imaging (DEI) experimental setup the contrast of the image collected at the top of the rocking curve is always higher than that of the apparent absorption image. Moreover, our experimental data confirm that the quality of a refraction image is superior to a refraction-like image. In order to understand the observed behavior we introduce and discuss the contribution of a new term in the classical DEI equation.

  20. Image enhancement using thermal-visible fusion for human detection

    Science.gov (United States)

    Zaihidee, Ezrinda Mohd; Hawari Ghazali, Kamarul; Zuki Saleh, Mohd

    2017-09-01

    An increased interest in detecting human beings in video surveillance system has emerged in recent years. Multisensory image fusion deserves more research attention due to the capability to improve the visual interpretability of an image. This study proposed fusion techniques for human detection based on multiscale transform using grayscale visual light and infrared images. The samples for this study were taken from online dataset. Both images captured by the two sensors were decomposed into high and low frequency coefficients using Stationary Wavelet Transform (SWT). Hence, the appropriate fusion rule was used to merge the coefficients and finally, the final fused image was obtained by using inverse SWT. From the qualitative and quantitative results, the proposed method is more superior than the two other methods in terms of enhancement of the target region and preservation of details information of the image.

  1. Content dependent selection of image enhancement parameters for mobile displays

    Science.gov (United States)

    Lee, Yoon-Gyoo; Kang, Yoo-Jin; Kim, Han-Eol; Kim, Ka-Hee; Kim, Choon-Woo

    2011-01-01

    Mobile devices such as cellular phones and portable multimedia player with capability of playing terrestrial digital multimedia broadcasting (T-DMB) contents have been introduced into consumer market. In this paper, content dependent image quality enhancement method for sharpness and colorfulness and noise reduction is presented to improve perceived image quality on mobile displays. Human visual experiments are performed to analyze viewers' preference. Relationship between the objective measures and the optimal values of image control parameters are modeled by simple lookup tables based on the results of human visual experiments. Content dependent values of image control parameters are determined based on the calculated measures and predetermined lookup tables. Experimental results indicate that dynamic selection of image control parameters yields better image quality.

  2. Gd-DTPA-enhanced MR imaging in facial nerve paralysis

    International Nuclear Information System (INIS)

    Tien, R.D.; Dillon, W.P.

    1989-01-01

    GD-DTPA-enhanced MR imaging was used to evaluate 11 patients with facial nerve paralysis (five acute idiopathic facial palsy (Bell palsy), three chronic recurrent facial palsy, one acute facial palsy after local radiation therapy, one chronic facial dyskinesia, and one facial neuroma). In eight of 11 patients, there was marked enhancement of the infratemporal facial nerve from the labyrinthine segment to the stylomastoid foramen. Two patients had additional contrast enhancement in the internal auditory canal segment. In one patient, enhancement persisted (but to a lesser degree) 8 weeks after symptoms had resolved. In one patient, no enhancement was seen 15 months after resolution of Bell palsy. The facial neuroma was seen as a focal nodular enhancement in the mastoid segment of the facial nerve

  3. Manganese-enhanced magnetic resonance imaging (MEMRI).

    Science.gov (United States)

    Koretsky, Alan P; Silva, Afonso C

    2004-12-01

    Manganese ion (Mn2+) is an essential metal that participates as a cofactor in a number of critical biological functions, such as electron transport, detoxification of free radicals and synthesis of neurotransmitters. Mn2+ can enter excitable cells using some of the same transport systems as Ca2+ and it can bind to a number of intracellular sites because it has high affinity for Ca2+ and Mg2+ binding sites on proteins and nucleic acids. Paramagnetic forms of manganese ions are potent MRI relaxation agents. Indeed, Mn2+ was the first contrast agent proposed for use in MRI. Recently, there has been renewed interest in combining the strong MRI relaxation effects of Mn2+ with its unique biology, in order to further expand the already broad assortment of useful information that can be measured by MRI. Such an approach has been continuously developed in the past several years to provide unique tissue contrast, to assess tissue viability, to act as a surrogate marker of calcium influx into cells and to trace neuronal connections. This special issue of NMR in Biomedicine on manganese-enhanced MRI (MEMRI) is aimed at providing the readers of this journal with an extensive review of some of the most prominent applications of MEMRI in biological systems. Written by several of the leaders in the field, the reviews and original research articles featured in this special issue are likely to offer an exciting and inspiring view of the broad range of applications of MEMRI. Copyright 2004 John Wiley & Sons, Ltd.

  4. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    International Nuclear Information System (INIS)

    Soevik, Aaste; Skogmo, Hege K.; Roedal, Jan; Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik

    2010-01-01

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  5. Recurrent postoperative sciatica: Evaluation with MR imaging and enhanced CT

    International Nuclear Information System (INIS)

    Duoauferrier, R.; Frocrain, L.; Husson, J.L.

    1987-01-01

    The authors prospectively compared surface coil MR (SCMR) imaging and CT with iodinate contrast enhancement in 50 patients with recurrent postoperative sciatica. Of the 50 patients enrolled in the study, surgical treatment was elected in 27 patients after independent examination of SCMR imaging and enhanced CT. All predictions made with the 27 SCMR images were surgically confirmed. The surgical findings were 20 recurrent disk herniations, five recurrent disk herniations with scar tissue, one disk herniation above the level of diskectomy, and one disk herniation below the level of diskectomy. The surgical findings of the 12 patients who had scar tissue on CT were seven recurrent disk herniations, four recurrent disk herniations with scar tissue, and one disk herniation below the operated level. SCMR imaging was more sensitive and more specific than CT to differentiate scar tissue from recurrent disk herniation

  6. Image contrast enhancement based on a local standard deviation model

    International Nuclear Information System (INIS)

    Chang, Dah-Chung; Wu, Wen-Rong

    1996-01-01

    The adaptive contrast enhancement (ACE) algorithm is a widely used image enhancement method, which needs a contrast gain to adjust high frequency components of an image. In the literature, the gain is usually inversely proportional to the local standard deviation (LSD) or is a constant. But these cause two problems in practical applications, i.e., noise overenhancement and ringing artifact. In this paper a new gain is developed based on Hunt's Gaussian image model to prevent the two defects. The new gain is a nonlinear function of LSD and has the desired characteristic emphasizing the LSD regions in which details are concentrated. We have applied the new ACE algorithm to chest x-ray images and the simulations show the effectiveness of the proposed algorithm

  7. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, C. Zuhal E-mail: sunarerdem@yahoo.com; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-07-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T{sub p}); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T{sub p} were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS.

  8. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    International Nuclear Information System (INIS)

    Erdem, C. Zuhal; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-01-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T p ); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T p were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS

  9. Quantifying the effect of colorization enhancement on mammogram images

    Science.gov (United States)

    Wojnicki, Paul J.; Uyeda, Elizabeth; Micheli-Tzanakou, Evangelia

    2002-04-01

    Current methods of radiological displays provide only grayscale images of mammograms. The limitation of the image space to grayscale provides only luminance differences and textures as cues for object recognition within the image. However, color can be an important and significant cue in the detection of shapes and objects. Increasing detection ability allows the radiologist to interpret the images in more detail, improving object recognition and diagnostic accuracy. Color detection experiments using our stimulus system, have demonstrated that an observer can only detect an average of 140 levels of grayscale. An optimally colorized image can allow a user to distinguish 250 - 1000 different levels, hence increasing potential image feature detection by 2-7 times. By implementing a colorization map, which follows the luminance map of the original grayscale images, the luminance profile is preserved and color is isolated as the enhancement mechanism. The effect of this enhancement mechanism on the shape, frequency composition and statistical characteristics of the Visual Evoked Potential (VEP) are analyzed and presented. Thus, the effectiveness of the image colorization is measured quantitatively using the Visual Evoked Potential (VEP).

  10. Robust algebraic image enhancement for intelligent control systems

    Science.gov (United States)

    Lerner, Bao-Ting; Morrelli, Michael

    1993-01-01

    Robust vision capability for intelligent control systems has been an elusive goal in image processing. The computationally intensive techniques a necessary for conventional image processing make real-time applications, such as object tracking and collision avoidance difficult. In order to endow an intelligent control system with the needed vision robustness, an adequate image enhancement subsystem capable of compensating for the wide variety of real-world degradations, must exist between the image capturing and the object recognition subsystems. This enhancement stage must be adaptive and must operate with consistency in the presence of both statistical and shape-based noise. To deal with this problem, we have developed an innovative algebraic approach which provides a sound mathematical framework for image representation and manipulation. Our image model provides a natural platform from which to pursue dynamic scene analysis, and its incorporation into a vision system would serve as the front-end to an intelligent control system. We have developed a unique polynomial representation of gray level imagery and applied this representation to develop polynomial operators on complex gray level scenes. This approach is highly advantageous since polynomials can be manipulated very easily, and are readily understood, thus providing a very convenient environment for image processing. Our model presents a highly structured and compact algebraic representation of grey-level images which can be viewed as fuzzy sets.

  11. Characterisation of a resolution enhancing image inversion interferometer.

    Science.gov (United States)

    Wicker, Kai; Sindbert, Simon; Heintzmann, Rainer

    2009-08-31

    Image inversion interferometers have the potential to significantly enhance the lateral resolution and light efficiency of scanning fluorescence microscopes. Self-interference of a point source's coherent point spread function with its inverted copy leads to a reduction in the integrated signal for off-axis sources compared to sources on the inversion axis. This can be used to enhance the resolution in a confocal laser scanning microscope. We present a simple image inversion interferometer relying solely on reflections off planar surfaces. Measurements of the detection point spread function for several types of light sources confirm the predicted performance and suggest its usability for scanning confocal fluorescence microscopy.

  12. The Effect of Multispectral Image Fusion Enhancement on Human Efficiency

    Science.gov (United States)

    2017-03-20

    and discrete wavelet transformation (DWT). A seventh function was added after we noticed a number of cases where PCA produced uninterpretable...component analysis and adjusted PCA Principal component analysis (PCA) is a general math - ematical technique that transforms a set of potentially correlated...equivalent to sampling the image with Laplacian operators of many scales, which tends to enhance salient image features. Discrete wavelet transform The

  13. Elevational spatial compounding for enhancing image quality in echocardiography

    OpenAIRE

    Perperidis, Antonios; McDicken, Norman; MacGillivray, Tom; Anderson, Tom

    2016-01-01

    Introduction Echocardiography is commonly used in clinical practice for the real-time assessment of cardiac morphology and function. Nevertheless, due to the nature of the data acquisition, cardiac ultrasound images are often corrupted by a range of acoustic artefacts, including acoustic noise, speckle and shadowing. Spatial compounding techniques have long been recognised for their ability to suppress common ultrasound artefacts, enhancing the imaged cardiac structures. However, they require...

  14. THE EFFECT OF IMAGE ENHANCEMENT METHODS DURING FEATURE DETECTION AND MATCHING OF THERMAL IMAGES

    Directory of Open Access Journals (Sweden)

    O. Akcay

    2017-05-01

    Full Text Available A successful image matching is essential to provide an automatic photogrammetric process accurately. Feature detection, extraction and matching algorithms have performed on the high resolution images perfectly. However, images of cameras, which are equipped with low-resolution thermal sensors are problematic with the current algorithms. In this paper, some digital image processing techniques were applied to the low-resolution images taken with Optris PI 450 382 x 288 pixel optical resolution lightweight thermal camera to increase extraction and matching performance. Image enhancement methods that adjust low quality digital thermal images, were used to produce more suitable images for detection and extraction. Three main digital image process techniques: histogram equalization, high pass and low pass filters were considered to increase the signal-to-noise ratio, sharpen image, remove noise, respectively. Later on, the pre-processed images were evaluated using current image detection and feature extraction methods Maximally Stable Extremal Regions (MSER and Speeded Up Robust Features (SURF algorithms. Obtained results showed that some enhancement methods increased number of extracted features and decreased blunder errors during image matching. Consequently, the effects of different pre-process techniques were compared in the paper.

  15. MR imaging of the breast with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Hachiya, Junichi; Seki, Tsuneaki; Okada, Minoru; Nitatori, Toshiaki; Korenaga, Tateo; Furuya, Yoshiro

    1991-01-01

    The accuracy of MR imaging with Gd-DTPA enhancement was compared with mammography and ultrasonography in 52 patients with clinically palpable benign and malignant breast masses (36 carcinomas, 2 malignant phyllodes tumors, 7 fibroadenomas, 7 cysts). On dynamic MR imaging, carcinomas and fibroadenomas were discriminated by their different dynamic enhancement profiles. In carcinomas, signal intensity increased rapidly, reaching a peak or plateau within 2 min after the injection of contrast medium. In fibroadenomas, signal intensity showed a much slower continuous increase without ceasing until about 8 min after injection. Malignant phyllodes tumors showed a dynamic enhancement profile identical to that of benign fibroadenomas. MR imaging correctly identified 84% of malignant tumors, 86% of fibroadenomas, and 100% of cysts, and was substantially more accurate in tissue characterization than mammography. The results of ultrasonography were highly similar to those of MR imaging. However, no single modality was infallible, and the three modalities were complementary rather than competitive. Considering the high cost and long examination time of MR imaging, mammography supplemented by ultrasonography seems to be the method of choice in the diagnosis of breast lesions. Nevertheless, MR imaging can add important information when the results of mammography and ultrasonography are insufficient or contradictory. (author)

  16. Bioboxes: standardised containers for interchangeable bioinformatics software.

    Science.gov (United States)

    Belmann, Peter; Dröge, Johannes; Bremges, Andreas; McHardy, Alice C; Sczyrba, Alexander; Barton, Michael D

    2015-01-01

    Software is now both central and essential to modern biology, yet lack of availability, difficult installations, and complex user interfaces make software hard to obtain and use. Containerisation, as exemplified by the Docker platform, has the potential to solve the problems associated with sharing software. We propose bioboxes: containers with standardised interfaces to make bioinformatics software interchangeable.

  17. Standardisation of haemoglobinometry : History and new challenges

    NARCIS (Netherlands)

    Zijlstra, WG

    1997-01-01

    During the 1950s several attempts were made to standardise the measurement of the haemoglobin concentration in human blood, for which numerous different methods were in use giving widely different results. In 1966, a consensus was reached on the general use of a photometric determination after

  18. BIM Anatomy II: Standardisation Needs & Support Systems

    OpenAIRE

    Hooper, Martin

    2015-01-01

    This thesis presents the results of an investigation into BIM standardisation needs and procedural supporting mechanisms that may enable design, construction and operating (DCO) organisations to advance their deployment of Building Information Modelling (BIM) technology, and improve construction project outcomes. To achieve sustainable development requires effective information management. Building Information Modelling is of strategic importance for the development of effi...

  19. Hybrid Image Fusion for Sharpness Enhancement of Multi-Spectral Lunar Images

    Science.gov (United States)

    Awumah, Anna; Mahanti, Prasun; Robinson, Mark

    2016-10-01

    Image fusion enhances the sharpness of a multi-spectral (MS) image by incorporating spatial details from a higher-resolution panchromatic (Pan) image [1,2]. Known applications of image fusion for planetary images are rare, although image fusion is well-known for its applications to Earth-based remote sensing. In a recent work [3], six different image fusion algorithms were implemented and their performances were verified with images from the Lunar Reconnaissance Orbiter (LRO) Camera. The image fusion procedure obtained a high-resolution multi-spectral (HRMS) product from the LRO Narrow Angle Camera (used as Pan) and LRO Wide Angle Camera (used as MS) images. The results showed that the Intensity-Hue-Saturation (IHS) algorithm results in a high-spatial quality product while the Wavelet-based image fusion algorithm best preserves spectral quality among all the algorithms. In this work we show the results of a hybrid IHS-Wavelet image fusion algorithm when applied to LROC MS images. The hybrid method provides the best HRMS product - both in terms of spatial resolution and preservation of spectral details. Results from hybrid image fusion can enable new science and increase the science return from existing LROC images.[1] Pohl, Cle, and John L. Van Genderen. "Review article multisensor image fusion in remote sensing: concepts, methods and applications." International journal of remote sensing 19.5 (1998): 823-854.[2] Zhang, Yun. "Understanding image fusion." Photogramm. Eng. Remote Sens 70.6 (2004): 657-661.[3] Mahanti, Prasun et al. "Enhancement of spatial resolution of the LROC Wide Angle Camera images." Archives, XXIII ISPRS Congress Archives (2016).

  20. Biliary enhanced MR imaging by Gd-DTPA

    International Nuclear Information System (INIS)

    Ohkawa, Shinichi; Fujikura, Yuji; Kanai, Toshio; Hiramatsu, Kyoichi.

    1992-01-01

    Biliary enhanced MRI (BEMRI) by Gd-DTPA via PTCD and/or PTGBD tube for obstructive jaundice was performed in 8 patients. In all cases, biliary tract was clearly visualised as high signal intensity on T1 weighted images. On same images, primary lesion such as common bile duct cancer was also visualised as well as portal system. In addition, MR angiography (MRA) by 2D-time of flight method was performed. MRA with BEMRI shows portal encasement on the same image as biliary tract obstruction. This suggests MRA with BEMRI may replace the other modality for obstructive jaundice. (author)

  1. Enhancement of the facial nerve at MR imaging

    International Nuclear Information System (INIS)

    Gebarski, S.S.; Telian, S.; Niparko, J.

    1990-01-01

    In the few cases studied, normal facial nerves are reported to show no MR enhancement. Because this did not fit clinical experience, the authors designed a retrospective imaging review with anatomic correlation. Between June 1989 and June 1990, 175 patients underwent focused temporal bone MR imaging before and after administration of intravenous gadopentetate dimeglumine (0.1 mmol/kg). Exclusion criteria for the study included facial nerve dysfunction (subjective or objective); facial nerve mass; central nervous system infection, inflammation, or trauma; neurofibromatosis; or previous cranial surgery of any type. The following sequences were reviewed: GE 1.5-T axial spin-echo TR 567 msec, TE 20 msec, 256 x 192, 2.0 excitations, 20-cm field of view, 3-mm section thickness. Imaging analysis was a side-by side comparison of the images and region-of-interest quantified signal intensity. Anatomic correlation included a comparison with dissection and axial histologic sections. Ninety-three patients (aged 15-75 years) were available for imaging analysis after the exclusionary criteria were applied. With 46 patients (92 facial nerves) analyzed, they found that 76 nerves (83%) showed easily visible gadopentetate dimeglumine enhancement, especially about the geniculate ganglia. Sixteen (17%) of the 92 nerves did not show visible enhancement, but region-of-interest analysis showed increased intensity after gadopentetate dimeglumine administration. Sixteen patients (42%) showed right-to-left asymmetry in facial nerve enhancement. The facial nerves showed enhancement in the geniculate, tympanic, and fallopian portions; the facial nerve within the IAC showed no enhancement. This corresponded exactly with the topographic features of a circummeural arterial/venous plexus seen on the anatomic preparations

  2. Fuzzy Logic-Based Histogram Equalization for Image Contrast Enhancement

    Directory of Open Access Journals (Sweden)

    V. Magudeeswaran

    2013-01-01

    Full Text Available Fuzzy logic-based histogram equalization (FHE is proposed for image contrast enhancement. The FHE consists of two stages. First, fuzzy histogram is computed based on fuzzy set theory to handle the inexactness of gray level values in a better way compared to classical crisp histograms. In the second stage, the fuzzy histogram is divided into two subhistograms based on the median value of the original image and then equalizes them independently to preserve image brightness. The qualitative and quantitative analyses of proposed FHE algorithm are evaluated using two well-known parameters like average information contents (AIC and natural image quality evaluator (NIQE index for various images. From the qualitative and quantitative measures, it is interesting to see that this proposed method provides optimum results by giving better contrast enhancement and preserving the local information of the original image. Experimental result shows that the proposed method can effectively and significantly eliminate washed-out appearance and adverse artifacts induced by several existing methods. The proposed method has been tested using several images and gives better visual quality as compared to the conventional methods.

  3. Quantitative reconstruction from a single diffraction-enhanced image

    International Nuclear Information System (INIS)

    Paganin, D.M.; Lewis, R.A.; Kitchen, M.

    2003-01-01

    Full text: We develop an algorithm for using a single diffraction-enhanced image (DEI) to obtain a quantitative reconstruction of the projected thickness of a single-material sample which is embedded within a substrate of approximately constant thickness. This algorithm is used to quantitatively map inclusions in a breast phantom, from a single synchrotron DEI image. In particular, the reconstructed images quantitatively represent the projected thickness in the bulk of the sample, in contrast to DEI images which greatly emphasise sharp edges (high spatial frequencies). In the context of an ultimate aim of improved methods for breast cancer detection, the reconstructions are potentially of greater diagnostic value compared to the DEI data. Lastly, we point out that the methods of analysis presented here are also applicable to the quantitative analysis of differential interference contrast (DIC) images

  4. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    International Nuclear Information System (INIS)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo

    1994-01-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author)

  5. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1994-09-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author).

  6. Assessment of image display of contrast enhanced T1W images with fat suppression

    International Nuclear Information System (INIS)

    Miyazaki, Isao; Ishizaki, Keiko; Kobayashi, Kuninori; Katou, Masanobu

    2006-01-01

    The effects of imaging conditions and measures for their improvement were examined with regard to recognition of the effects of contrast on images when T 1 -weighted imaging with selective fat suppression was applied. Luminance at the target region was examined before and after contrast imaging using phantoms assuming pre- and post-imaging conditions. A clinical examination was performed on tumors revealed by breast examination, including those surrounded by mammary gland and by fat tissue. When fat suppression was used and imaging contrast was enhanced, the luminance level of fat tumors with the same structure as the prepared phantoms appeared to be high both before and after contrast imaging, and the effects of contrast were not distinguishable. This observation is attributable to the fact that the imaging conditions before and after contrast imaging were substantially different. To make a comparison between pre- and post-contrast images, it is considered necessary to perform imaging with fixed receiver gain and to apply the same imaging method for pre- and post-contrast images by adjusting post-contrast imaging conditions to those of pre-contrast imaging. (author)

  7. Body enhancement : body images, vulnerability and moral responsibility

    NARCIS (Netherlands)

    den Dikken, A.

    2011-01-01

    The objective of this explorative study is to show that it is highly relevant to integrate cultural and personal body images into the ethical debate on human enhancement. The current debate has little attention for the motivations to make use of technology to alter the human body, such as cultural

  8. Surface Reconstruction and Image Enhancement via $L^1$-Minimization

    KAUST Repository

    Dobrev, Veselin

    2010-01-01

    A surface reconstruction technique based on minimization of the total variation of the gradient is introduced. Convergence of the method is established, and an interior-point algorithm solving the associated linear programming problem is introduced. The reconstruction algorithm is illustrated on various test cases including natural and urban terrain data, and enhancement oflow-resolution or aliased images. Copyright © by SIAM.

  9. Enhancing SDO/HMI images using deep learning

    Science.gov (United States)

    Baso, C. J. Díaz; Ramos, A. Asensio

    2018-06-01

    Context. The Helioseismic and Magnetic Imager (HMI) provides continuum images and magnetograms with a cadence better than one per minute. It has been continuously observing the Sun 24 h a day for the past 7 yr. The trade-off between full disk observations and spatial resolution means that HMI is not adequate for analyzing the smallest-scale events in the solar atmosphere. Aims: Our aim is to develop a new method to enhance HMI data, simultaneously deconvolving and super-resolving images and magnetograms. The resulting images will mimic observations with a diffraction-limited telescope twice the diameter of HMI. Methods: Our method, which we call Enhance, is based on two deep, fully convolutional neural networks that input patches of HMI observations and output deconvolved and super-resolved data. The neural networks are trained on synthetic data obtained from simulations of the emergence of solar active regions. Results: We have obtained deconvolved and super-resolved HMI images. To solve this ill-defined problem with infinite solutions we have used a neural network approach to add prior information from the simulations. We test Enhance against Hinode data that has been degraded to a 28 cm diameter telescope showing very good consistency. The code is open source.

  10. Temporal contrast enhancement and parametric imaging for the visualisation of time patterns in dynamic scintigraphic imaging

    International Nuclear Information System (INIS)

    Deconinck, F.; Bossuyt, A.; Lepoudre, R.

    1982-01-01

    Image contrast, photon noise and sampling frequency limit the visual extraction of relevant temporal information in scintigraphic image series. When the Unitation is mainly due to low temporal contrast, temporal contrast enhancement will strongly improve the perceptibility of time patterns in the series. When the limitation is due to photon noise and limited temporal sampling, parametric imaging by means of the Hadamard transform can visualise temporal patterns. (WU)

  11. Automatic anatomically selective image enhancement in digital chest radiography

    International Nuclear Information System (INIS)

    Sezan, M.I.; Minerbo, G.N.; Schaetzing, R.

    1989-01-01

    The authors develop a technique for automatic anatomically selective enhancement of digital chest radiographs. Anatomically selective enhancement is motivated by the desire to simultaneously meet the different enhancement requirements of the lung field and the mediastinum. A recent peak detection algorithm and a set of rules are applied to the image histogram to determine automatically a gray-level threshold between the lung field and mediastinum. The gray-level threshold facilitates anatomically selective gray-scale modification and/or unsharp masking. Further, in an attempt to suppress possible white-band or black-band artifacts due to unsharp masking at sharp edges, local-contrast adaptivity is incorporated into anatomically selective unsharp masking by designing an anatomy-sensitive emphasis parameter which varies asymmetrically with positive and negative values of the local image contrast

  12. Enhancement system of nighttime infrared video image and visible video image

    Science.gov (United States)

    Wang, Yue; Piao, Yan

    2016-11-01

    Visibility of Nighttime video image has a great significance for military and medicine areas, but nighttime video image has so poor quality that we can't recognize the target and background. Thus we enhance the nighttime video image by fuse infrared video image and visible video image. According to the characteristics of infrared and visible images, we proposed improved sift algorithm andαβ weighted algorithm to fuse heterologous nighttime images. We would deduced a transfer matrix from improved sift algorithm. The transfer matrix would rapid register heterologous nighttime images. And theαβ weighted algorithm can be applied in any scene. In the video image fusion system, we used the transfer matrix to register every frame and then used αβ weighted method to fuse every frame, which reached the time requirement soft video. The fused video image not only retains the clear target information of infrared video image, but also retains the detail and color information of visible video image and the fused video image can fluency play.

  13. Quantitative comparison between two geometrical layouts for diffraction enhanced imaging

    International Nuclear Information System (INIS)

    Huang Wanxia; Yuan Qingxi; Zhu Peiping; Wang Junyue; Shu Hang; Chen Bo; Hu Tiandou; Wu Ziyu

    2007-01-01

    Diffraction enhanced imaging (DEI) with two crystals has been performed at the 4W1A beamline at Beijing Synchrotron Radiation Facility (BSRF). Two different crystal geometrical layouts were used to collect images, in the first layout the rotation axis of the crystal has been set perpendicular to the orbital plane while in the second the axis is parallel to the orbital plane. Performance comparison between the two layouts is discussed in terms of thermal expansion of the crystal induced by the heat load, imaging homogeneity, spatial resolution and angular resolution. From both experimental and theoretical data we show that the best images may be obtained with the optical layout in which the rotation axis of the crystals is perpendicular to the orbital plane

  14. Quantitative comparison between two geometrical layouts for diffraction enhanced imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huang Wanxia; Yuan Qingxi [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China); Zhu Peiping [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China)], E-mail: zhupp@ihep.ac.cn; Wang Junyue; Shu Hang [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China); Chen Bo [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China); Department of Physics, University of Science and Technology of China, Hefei (China); Hu Tiandou [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China); Wu Ziyu [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China)], E-mail: wuzy@ihep.ac.cn

    2007-07-15

    Diffraction enhanced imaging (DEI) with two crystals has been performed at the 4W1A beamline at Beijing Synchrotron Radiation Facility (BSRF). Two different crystal geometrical layouts were used to collect images, in the first layout the rotation axis of the crystal has been set perpendicular to the orbital plane while in the second the axis is parallel to the orbital plane. Performance comparison between the two layouts is discussed in terms of thermal expansion of the crystal induced by the heat load, imaging homogeneity, spatial resolution and angular resolution. From both experimental and theoretical data we show that the best images may be obtained with the optical layout in which the rotation axis of the crystals is perpendicular to the orbital plane.

  15. Image quality enhancement for skin cancer optical diagnostics

    Science.gov (United States)

    Bliznuks, Dmitrijs; Kuzmina, Ilona; Bolocko, Katrina; Lihachev, Alexey

    2017-12-01

    The research presents image quality analysis and enhancement proposals in biophotonic area. The sources of image problems are reviewed and analyzed. The problems with most impact in biophotonic area are analyzed in terms of specific biophotonic task - skin cancer diagnostics. The results point out that main problem for skin cancer analysis is the skin illumination problems. Since it is often not possible to prevent illumination problems, the paper proposes image post processing algorithm - low frequency filtering. Practical results show diagnostic results improvement after using proposed filter. Along that, filter do not reduces diagnostic results' quality for images without illumination defects. Current filtering algorithm requires empirical tuning of filter parameters. Further work needed to test the algorithm in other biophotonic applications and propose automatic filter parameter selection.

  16. Evaluation of a Mathematical Model for Digital Image Enhancement.

    Science.gov (United States)

    Geha, Hassem; Nasseh, Ibrahim; Noujeim, Marcel

    2015-01-01

    The purpose of this study is to compare the detected number of holes on a stepwedge on images resulting from the application of the 5th degree polynomial model compared to the images resulting from the application of linear enhancement. Material and Methods : A 10-step aluminum step wedge with holes randomly drilled on each step was exposed with three different kVp and five exposure times per kVp on a Schick33(®) sensor. The images were enhanced by brightness/contrast adjustment, histogram equalization and with the 5th degree polynomial model and compared to the original non-enhanced images by six observers in two separate readings. Results : There was no significant difference between the readers and between the first and second reading. There was a significant three-factor interaction among Method, Exposure time, and kVp in detecting holes. The overall pattern was: "Poly" results in the highest counts, "Original" in the lowest counts, with "B/C" and "Equalized" intermediate. Conclusion : The 5th degree polynomial model showed more holes when compared to the other modalities.

  17. Oriented diffusion filtering for enhancing low-quality fingerprint images

    KAUST Repository

    Gottschlich, C.; Schönlieb, C.-B.

    2012-01-01

    To enhance low-quality fingerprint images, we present a novel method that first estimates the local orientation of the fingerprint ridge and valley flow and next performs oriented diffusion filtering, followed by a locally adaptive contrast enhancement step. By applying the authors' new approach to low-quality images of the FVC2004 fingerprint databases, the authors are able to show its competitiveness with other state-of-the-art enhancement methods for fingerprints like curved Gabor filtering. A major advantage of oriented diffusion filtering over those is its computational efficiency. Combining oriented diffusion filtering with curved Gabor filters led to additional improvements and, to the best of the authors' knowledge, the lowest equal error rates achieved so far using MINDTCT and BOZORTH3 on the FVC2004 databases. The recognition performance and the computational efficiency of the method suggest to include oriented diffusion filtering as a standard image enhancement add-on module for real-time fingerprint recognition systems. In order to facilitate the reproduction of these results, an implementation of the oriented diffusion filtering for Matlab and GNU Octave is made available for download. © 2012 The Institution of Engineering and Technology.

  18. Oriented diffusion filtering for enhancing low-quality fingerprint images

    KAUST Repository

    Gottschlich, C.

    2012-01-01

    To enhance low-quality fingerprint images, we present a novel method that first estimates the local orientation of the fingerprint ridge and valley flow and next performs oriented diffusion filtering, followed by a locally adaptive contrast enhancement step. By applying the authors\\' new approach to low-quality images of the FVC2004 fingerprint databases, the authors are able to show its competitiveness with other state-of-the-art enhancement methods for fingerprints like curved Gabor filtering. A major advantage of oriented diffusion filtering over those is its computational efficiency. Combining oriented diffusion filtering with curved Gabor filters led to additional improvements and, to the best of the authors\\' knowledge, the lowest equal error rates achieved so far using MINDTCT and BOZORTH3 on the FVC2004 databases. The recognition performance and the computational efficiency of the method suggest to include oriented diffusion filtering as a standard image enhancement add-on module for real-time fingerprint recognition systems. In order to facilitate the reproduction of these results, an implementation of the oriented diffusion filtering for Matlab and GNU Octave is made available for download. © 2012 The Institution of Engineering and Technology.

  19. Image quality enhancement in low-light-level ghost imaging using modified compressive sensing method

    Science.gov (United States)

    Shi, Xiaohui; Huang, Xianwei; Nan, Suqin; Li, Hengxing; Bai, Yanfeng; Fu, Xiquan

    2018-04-01

    Detector noise has a significantly negative impact on ghost imaging at low light levels, especially for existing recovery algorithm. Based on the characteristics of the additive detector noise, a method named modified compressive sensing ghost imaging is proposed to reduce the background imposed by the randomly distributed detector noise at signal path. Experimental results show that, with an appropriate choice of threshold value, modified compressive sensing ghost imaging algorithm can dramatically enhance the contrast-to-noise ratio of the object reconstruction significantly compared with traditional ghost imaging and compressive sensing ghost imaging methods. The relationship between the contrast-to-noise ratio of the reconstruction image and the intensity ratio (namely, the average signal intensity to average noise intensity ratio) for the three reconstruction algorithms are also discussed. This noise suppression imaging technique will have great applications in remote-sensing and security areas.

  20. Enhanced EDX images by fusion of multimodal SEM images using pansharpening techniques.

    Science.gov (United States)

    Franchi, G; Angulo, J; Moreaud, M; Sorbier, L

    2018-01-01

    The goal of this paper is to explore the potential interest of image fusion in the context of multimodal scanning electron microscope (SEM) imaging. In particular, we aim at merging the backscattered electron images that usually have a high spatial resolution but do not provide enough discriminative information to physically classify the nature of the sample, with energy-dispersive X-ray spectroscopy (EDX) images that have discriminative information but a lower spatial resolution. The produced images are named enhanced EDX. To achieve this goal, we have compared the results obtained with classical pansharpening techniques for image fusion with an original approach tailored for multimodal SEM fusion of information. Quantitative assessment is obtained by means of two SEM images and a simulated dataset produced by a software based on PENELOPE. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  1. Multicentre chest computed tomography standardisation in children and adolescents with cystic fibrosis

    DEFF Research Database (Denmark)

    Kuo, Wieying; Kemner-van de Corput, Mariette P. C.; Perez-Rovira, Adria

    2016-01-01

    Progressive cystic fibrosis (CF) lung disease is the main cause of mortality in CF patients. CF lung disease starts in early childhood. With current standards of care, respiratory function remains largely normal in children and more sensitive outcome measures are needed to monitor early CF lung...... disease. Chest CT is currently the most sensitive imaging modality to monitor pulmonary structural changes in children and adolescents with CF. To quantify structural lung disease reliably among multiple centres, standardisation of chest CT protocols is needed. SCIFI CF (Standardised Chest Imaging...

  2. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging.

    Science.gov (United States)

    Sogani, Julie; Morris, Elizabeth A; Kaplan, Jennifer B; D'Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S; Jochelson, Maxine S

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P spectral mammographic and MR images. © RSNA, 2016.

  3. Polarization imaging enhancement for target vision through haze

    Science.gov (United States)

    Wu, Hai-Ying; Zhang, San-Xi; Li, Jie; LI, Bin; Tang, Zi-li; Liu, Biao; Jia, Wen-Wu

    2016-10-01

    Haze, fog, and smoke are turbid medium in the atmosphere which usually degrade viewing condition of outdoor scenes. The resulted images lose contrast and color fidelity with serious degradation. Due to loss of large detailed information of measured scene, it will usually lead to invalid detection and measurement. The suspended particles in the atmosphere and the scene being measured give rise to polarization changes by their reflection. In the process of reflection, absorption and scattering, the object itself can be determined by its own polarization characteristics. Based on this point, we proposed an approach for target vision through haze. This approach is based on the polarization differences between the scene being measured and the scattering background to move the haze effects. It can realize a great visibility enhancement and enable the scene rendering even if imaged under restricted viewing conditions with low polarization. In this work, the detailed theoretical operation principle is presented. A validating imaging system is established and the corresponding experiment is carried out. We present the experimental results of haze-free image of scene with recovered high contrast. This method also can be used to effectively enhance the imaging performance of any other optical system.

  4. Iris image enhancement for feature recognition and extraction

    CSIR Research Space (South Africa)

    Mabuza, GP

    2012-10-01

    Full Text Available the employment of other algorithms and commands so as to better present and demonstrate the obtained results. Edge detection and enhancing images for use in an iris recognition system allow for efficient recognition and extraction of iris patterns. REFERENCES... Gonzalez, R.C. and Woods, R.E. 2002. Digital Image Processing 2nd Edition, Instructor?s manual .Englewood Cliffs, Prentice Hall, pp 17-36. Proen?a, H. and Alexandre, L.A. 2007. Toward Noncooperative Iris Recognition: A classification approach using...

  5. Image Enhancer: A Graphic Editor to Apply Numerous Effects in Digital Image

    Directory of Open Access Journals (Sweden)

    Abhisek Hazra

    2014-12-01

    Full Text Available Image Enhancer is an open source, portable graphic editor developed for Windows platform. It is equipped with an enriched set of digital imaging filters with advanced computer vision techniques embedded within, like Interest Point Detection (Susan Corner Detector, Linear Edge Detection (Simple, Sobel, Canny, Histogram Equalization, Dithering (Bayer, Burkes, Sierra, Jarvis Judis Ninke, Transforming to Polar images and vice versa etc.  Image Enhancer was released under GNU Lesser General Public License (LGPL and the software was made available from the Microsoft’s open source project hosting repository Codeplex (http://imageenhancer.codeplex.com. Image Enhancer was tested and hosted by several popular software archives like SoftPedia, CNET, Freeware Files, ZDNet, Soft Tango and others. A stable Release Candidate (RC version has been made available in which some major modifications were done which were not present in the earlier Beta version. The download link for the Image Enhancer (both Release Candidate & Beta Version from CodePlex repository is (http://imageenhancer.codeplex.com/releases.

  6. Managing IT infrastructure standardisation in the networked manufacturing firm

    NARCIS (Netherlands)

    Akkermans, H.A.; Horst, van der H.

    2002-01-01

    This paper discusses managerial aspects of information technology (IT) infrastructure standardisation in networked manufacturing firms. It shows that in these firms, where local initiative is very important and strict central hierarchical control is lacking, standardisation of IT infrastructure is

  7. Exploring the use of memory colors for image enhancement

    Science.gov (United States)

    Xue, Su; Tan, Minghui; McNamara, Ann; Dorsey, Julie; Rushmeier, Holly

    2014-02-01

    Memory colors refer to those colors recalled in association with familiar objects. While some previous work introduces this concept to assist digital image enhancement, their basis, i.e., on-screen memory colors, are not appropriately investigated. In addition, the resulting adjustment methods developed are not evaluated from a perceptual view of point. In this paper, we first perform a context-free perceptual experiment to establish the overall distributions of screen memory colors for three pervasive objects. Then, we use a context-based experiment to locate the most representative memory colors; at the same time, we investigate the interactions of memory colors between different objects. Finally, we show a simple yet effective application using representative memory colors to enhance digital images. A user study is performed to evaluate the performance of our technique.

  8. Localized surface plasmon enhanced cellular imaging using random metallic structures

    Science.gov (United States)

    Son, Taehwang; Lee, Wonju; Kim, Donghyun

    2017-02-01

    We have studied fluorescence cellular imaging with randomly distributed localized near-field induced by silver nano-islands. For the fabrication of nano-islands, a 10-nm silver thin film evaporated on a BK7 glass substrate with an adhesion layer of 2-nm thick chromium. Micrometer sized silver square pattern was defined using e-beam lithography and then the film was annealed at 200°C. Raw images were restored using electric field distribution produced on the surface of random nano-islands. Nano-islands were modeled from SEM images. 488-nm p-polarized light source was set to be incident at 60°. Simulation results show that localized electric fields were created among nano-islands and that their average size was found to be 135 nm. The feasibility was tested using conventional total internal reflection fluorescence microscopy while the angle of incidence was adjusted to maximize field enhancement. Mouse microphage cells were cultured on nano-islands, and actin filaments were selectively stained with FITC-conjugated phalloidin. Acquired images were deconvolved based on linear imaging theory, in which molecular distribution was sampled by randomly distributed localized near-field and blurred by point spread function of far-field optics. The optimum fluorophore distribution was probabilistically estimated by repetitively matching a raw image. The deconvolved images are estimated to have a resolution in the range of 100-150 nm largely determined by the size of localized near-fields. We also discuss and compare the results with images acquired with periodic nano-aperture arrays in various optical configurations to excite localized plasmonic fields and to produce super-resolved molecular images.

  9. Cumulative phase delay imaging for contrast-enhanced ultrasound tomography

    International Nuclear Information System (INIS)

    Demi, Libertario; Van Sloun, Ruud J G; Wijkstra, Hessel; Mischi, Massimo

    2015-01-01

    Standard dynamic-contrast enhanced ultrasound (DCE-US) imaging detects and estimates ultrasound-contrast-agent (UCA) concentration based on the amplitude of the nonlinear (harmonic) components generated during ultrasound (US) propagation through UCAs. However, harmonic components generation is not specific to UCAs, as it also occurs for US propagating through tissue. Moreover, nonlinear artifacts affect standard DCE-US imaging, causing contrast to tissue ratio reduction, and resulting in possible misclassification of tissue and misinterpretation of UCA concentration. Furthermore, no contrast-specific modality exists for DCE-US tomography; in particular speed-of-sound changes due to UCAs are well within those caused by different tissue types. Recently, a new marker for UCAs has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental component is in fact observable for US propagating through UCAs, and is absent in tissue. In this paper, tomographic US images based on CPD are for the first time presented and compared to speed-of-sound US tomography. Results show the applicability of this marker for contrast specific US imaging, with cumulative phase delay imaging (CPDI) showing superior capabilities in detecting and localizing UCA, as compared to speed-of-sound US tomography. Cavities (filled with UCA) which were down to 1 mm in diameter were clearly detectable. Moreover, CPDI is free of the above mentioned nonlinear artifacts. These results open important possibilities to DCE-US tomography, with potential applications to breast imaging for cancer localization. (fast track communication)

  10. Superparamagnetic nanoparticles for enhanced magnetic resonance and multimodal imaging

    Science.gov (United States)

    Sikma, Elise Ann Schultz

    Magnetic resonance imaging (MRI) is a powerful tool for noninvasive tomographic imaging of biological systems with high spatial and temporal resolution. Superparamagnetic (SPM) nanoparticles have emerged as highly effective MR contrast agents due to their biocompatibility, ease of surface modification and magnetic properties. Conventional nanoparticle contrast agents suffer from difficult synthetic reproducibility, polydisperse sizes and weak magnetism. Numerous synthetic techniques and nanoparticle formulations have been developed to overcome these barriers. However, there are still major limitations in the development of new nanoparticle-based probes for MR and multimodal imaging including low signal amplification and absence of biochemical reporters. To address these issues, a set of multimodal (T2/optical) and dual contrast (T1/T2) nanoparticle probes has been developed. Their unique magnetic properties and imaging capabilities were thoroughly explored. An enzyme-activatable contrast agent is currently being developed as an innovative means for early in vivo detection of cancer at the cellular level. Multimodal probes function by combining the strengths of multiple imaging techniques into a single agent. Co-registration of data obtained by multiple imaging modalities validates the data, enhancing its quality and reliability. A series of T2/optical probes were successfully synthesized by attachment of a fluorescent dye to the surface of different types of nanoparticles. The multimodal nanoparticles generated sufficient MR and fluorescence signal to image transplanted islets in vivo. Dual contrast T1/T2 imaging probes were designed to overcome disadvantages inherent in the individual T1 and T2 components. A class of T1/T2 agents was developed consisting of a gadolinium (III) complex (DTPA chelate or DO3A macrocycle) conjugated to a biocompatible silica-coated metal oxide nanoparticle through a disulfide linker. The disulfide linker has the ability to be reduced

  11. Recurrent postoperative sciatica: Evaluation with MR imaging and enhanced CT

    International Nuclear Information System (INIS)

    Duvauferrier, R.; Frocain, L.; Husson, J.L.

    1987-01-01

    The authors prospectively compared MR imaging performed with a surface coil and CT performed with iodinated contrast agent enhancement in 50 patients with recurrent postoperative sciatica. Surgical decision was an objective measure of accuracy. Surgical treatment was selected for 27 patients. All 27 underwent MR imaging. The 15 patients who underwent CT/surgical treatment were included in the 27 indications of SCMR. All predictions based on MR imaging findings were confirmed at surgery. There were 25 recurrent disk herniations, including five with scar tissue, and two disk herniations above or below the level of the diskectomy. In the 12 patients with scar tissue detected on CT there were seven recurrent disk hernitions, four recurrent disk herniations with scar tissue, and one disk herniation below the level of the diskectomy

  12. Contrast enhancement in EIT imaging of the brain

    International Nuclear Information System (INIS)

    Nissinen, A; Kaipio, J P; Vauhkonen, M; Kolehmainen, V

    2016-01-01

    We consider electrical impedance tomography (EIT) imaging of the brain. The brain is surrounded by the poorly conducting skull which has low conductivity compared to the brain. The skull layer causes a partial shielding effect which leads to weak sensitivity for the imaging of the brain tissue. In this paper we propose an approach based on the Bayesian approximation error approach, to enhance the contrast in brain imaging. With this approach, both the (uninteresting) geometry and the conductivity of the skull are embedded in the approximation error statistics, which leads to a computationally efficient algorithm that is able to detect features such as internal haemorrhage with significantly increased sensitivity and specificity. We evaluate the approach with simulations and phantom data. (paper)

  13. Contrast enhancement in EIT imaging of the brain.

    Science.gov (United States)

    Nissinen, A; Kaipio, J P; Vauhkonen, M; Kolehmainen, V

    2016-01-01

    We consider electrical impedance tomography (EIT) imaging of the brain. The brain is surrounded by the poorly conducting skull which has low conductivity compared to the brain. The skull layer causes a partial shielding effect which leads to weak sensitivity for the imaging of the brain tissue. In this paper we propose an approach based on the Bayesian approximation error approach, to enhance the contrast in brain imaging. With this approach, both the (uninteresting) geometry and the conductivity of the skull are embedded in the approximation error statistics, which leads to a computationally efficient algorithm that is able to detect features such as internal haemorrhage with significantly increased sensitivity and specificity. We evaluate the approach with simulations and phantom data.

  14. Enhanced Seismic Imaging of Turbidite Deposits in Chicontepec Basin, Mexico

    Science.gov (United States)

    Chavez-Perez, S.; Vargas-Meleza, L.

    2007-05-01

    We test, as postprocessing tools, a combination of migration deconvolution and geometric attributes to attack the complex problems of reflector resolution and detection in migrated seismic volumes. Migration deconvolution has been empirically shown to be an effective approach for enhancing the illumination of migrated images, which are blurred versions of the subsurface reflectivity distribution, by decreasing imaging artifacts, improving spatial resolution, and alleviating acquisition footprint problems. We utilize migration deconvolution as a means to improve the quality and resolution of 3D prestack time migrated results from Chicontepec basin, Mexico, a very relevant portion of the producing onshore sector of Pemex, the Mexican petroleum company. Seismic data covers the Agua Fria, Coapechaca, and Tajin fields. It exhibits acquisition footprint problems, migration artifacts and a severe lack of resolution in the target area, where turbidite deposits need to be characterized between major erosional surfaces. Vertical resolution is about 35 m and the main hydrocarbon plays are turbidite beds no more than 60 m thick. We also employ geometric attributes (e.g., coherent energy and curvature), computed after migration deconvolution, to detect and map out depositional features, and help design development wells in the area. Results of this workflow show imaging enhancement and allow us to identify meandering channels and individual sand bodies, previously undistinguishable in the original seismic migrated images.

  15. Enhanced 3D fluorescence live cell imaging on nanoplasmonic substrate

    International Nuclear Information System (INIS)

    Gartia, Manas Ranjan; Hsiao, Austin; Logan Liu, G; Sivaguru, Mayandi; Chen Yi

    2011-01-01

    We have created a randomly distributed nanocone substrate on silicon coated with silver for surface-plasmon-enhanced fluorescence detection and 3D cell imaging. Optical characterization of the nanocone substrate showed it can support several plasmonic modes (in the 300-800 nm wavelength range) that can be coupled to a fluorophore on the surface of the substrate, which gives rise to the enhanced fluorescence. Spectral analysis suggests that a nanocone substrate can create more excitons and shorter lifetime in the model fluorophore Rhodamine 6G (R6G) due to plasmon resonance energy transfer from the nanocone substrate to the nearby fluorophore. We observed three-dimensional fluorescence enhancement on our substrate shown from the confocal fluorescence imaging of chinese hamster ovary (CHO) cells grown on the substrate. The fluorescence intensity from the fluorophores bound on the cell membrane was amplified more than 100-fold as compared to that on a glass substrate. We believe that strong scattering within the nanostructured area coupled with random scattering inside the cell resulted in the observed three-dimensional enhancement in fluorescence with higher photostability on the substrate surface.

  16. Enhanced 3D fluorescence live cell imaging on nanoplasmonic substrate

    Energy Technology Data Exchange (ETDEWEB)

    Gartia, Manas Ranjan [Department of Nuclear, Plasma and Radiological Engineering, University of Illinois, Urbana, IL 61801 (United States); Hsiao, Austin; Logan Liu, G [Department of Bioengineering, University of Illinois, Urbana, IL 61801 (United States); Sivaguru, Mayandi [Institute for Genomic Biology, University of Illinois, Urbana, IL 61801 (United States); Chen Yi, E-mail: loganliu@illinois.edu [Department of Electrical and Computer Engineering, University of Illinois, Urbana, IL 61801 (United States)

    2011-09-07

    We have created a randomly distributed nanocone substrate on silicon coated with silver for surface-plasmon-enhanced fluorescence detection and 3D cell imaging. Optical characterization of the nanocone substrate showed it can support several plasmonic modes (in the 300-800 nm wavelength range) that can be coupled to a fluorophore on the surface of the substrate, which gives rise to the enhanced fluorescence. Spectral analysis suggests that a nanocone substrate can create more excitons and shorter lifetime in the model fluorophore Rhodamine 6G (R6G) due to plasmon resonance energy transfer from the nanocone substrate to the nearby fluorophore. We observed three-dimensional fluorescence enhancement on our substrate shown from the confocal fluorescence imaging of chinese hamster ovary (CHO) cells grown on the substrate. The fluorescence intensity from the fluorophores bound on the cell membrane was amplified more than 100-fold as compared to that on a glass substrate. We believe that strong scattering within the nanostructured area coupled with random scattering inside the cell resulted in the observed three-dimensional enhancement in fluorescence with higher photostability on the substrate surface.

  17. The Impact of Microlensing on the Standardisation of Strongly Lensed Type Ia Supernovae

    Science.gov (United States)

    Foxley-Marrable, Max; Collett, Thomas E.; Vernardos, Georgios; Goldstein, Daniel A.; Bacon, David

    2018-05-01

    We investigate the effect of microlensing on the standardisation of strongly lensed Type Ia supernovae (GLSNe Ia). We present predictions for the amount of scatter induced by microlensing across a range of plausible strong lens macromodels. We find that lensed images in regions of low convergence, shear and stellar density are standardisable, where the microlensing scatter is ≲ 0.15 magnitudes, comparable to the intrinsic dispersion of for a typical SN Ia. These standardisable configurations correspond to asymmetric lenses with an image located far outside the Einstein radius of the lens. Symmetric and small Einstein radius lenses (≲ 0.5 arcsec) are not standardisable. We apply our model to the recently discovered GLSN Ia iPTF16geu and find that the large discrepancy between the observed flux and the macromodel predictions from More et al. (2017) cannot be explained by microlensing alone. Using the mock GLSNe Ia catalogue of Goldstein et al. (2017), we predict that ˜ 22% of GLSNe Ia discovered by LSST will be standardisable, with a median Einstein radius of 0.9 arcseconds and a median time-delay of 41 days. By breaking the mass-sheet degeneracy the full LSST GLSNe Ia sample will be able to detect systematics in H0 at the 0.5% level.

  18. Gadolinium-enhanced magnetic resonance imaging in acute myocardial infarction

    International Nuclear Information System (INIS)

    Dijkman, P.R.M. van; Wall, E.E. van der; Roos, A. de; Doornbos, J.; Laarse, A. van der; Voorthuisen, A.E. van; Bruschke, A.V.G.; Rossum, A.C. van

    1990-01-01

    To evaluate he usefulness of the paramagnetic contrast agent Gadolinium-DTPA (diethylenetriaminepentaacetic acid) in Magnetic Resonance. Imaging of acute myocardial infarction, we studied a total of 45 patients with a first acute myocardial infarction by ECG-gated magnetic resonance imaging before and after intravenous administration of 0.1 mmol/kg Gadolinium-DTPA. All patients received thrombolytic treatment by intravenous streptokinase. The magnetic resonance imaging studies were preformed after a meam of 88 h (range 15-241) after the acute onset of acute myocardial infarction. Five patients without evidence of cardiac disease served as controls. Spin-echo measurements (TE 30 ms) were made using a Philips Gyroscan (0.5 Tesla) or a Teslacon II (0.6 Tesla). The 45 patients were divided into four groups of patients. In Group I( patients) Gadolinium-DTPA improved the detection of myocardial infarction by Gadolinium-DTPA. In Group II (20 patients) the magnetic resonance imaging procedure was repeated every 10 min for up to 40 min following administration of Gadolinium-DTPA. Optimal contrast enhancement was obtained 20-25 min after Gadolinium-DTPA. In Group III (27 patients) signal intensities were significantly higher in the patients who underwent the magnetic resonance imaging study more than 72 h (mean 120) after the acute event, suggesting increased acculumation of Gadolinium-DTPA in a more advanced stage of the infarction process. In Group IV (45 patients) Gadolinium-DTPA was administered in an attempt to distinguish between reperfused and nonreperfused myocardial areas after thrombolytic treatment for acute myocardial infarction. The signal intensities did not differ, but reperfused areas showed a more homogeneous aspect whereas nonreperfused areas were visualized as a more heterogeneous contrast enhancement. It is concluded that magnetic resonance imaging using the contrast agent Gadolinium-DTPA significantly improves the detection of infarcted myocardial areas

  19. Disgust enhances the recollection of negative emotional images.

    Directory of Open Access Journals (Sweden)

    Camilla J Croucher

    Full Text Available Memory is typically better for emotional relative to neutral images, an effect generally considered to be mediated by arousal. However, this explanation cannot explain the full pattern of findings in the literature. Two experiments are reported that investigate the differential effects of categorical affective states upon emotional memory and the contributions of stimulus dimensions other than pleasantness and arousal to any memory advantage. In Experiment 1, disgusting images were better remembered than equally unpleasant frightening ones, despite the disgusting images being less arousing. In Experiment 2, regression analyses identified affective impact--a factor shown previously to influence the allocation of visual attention and amygdala response to negative emotional images--as the strongest predictor of remembering. These findings raise significant issues that the arousal account of emotional memory cannot readily address. The term impact refers to an undifferentiated emotional response to a stimulus, without requiring detailed consideration of specific dimensions of image content. We argue that ratings of impact relate to how the self is affected. The present data call for further consideration of the theoretical specifications of the mechanisms that lead to enhanced memory for emotional stimuli and their neural substrates.

  20. Diffraction-enhanced imaging at the UK synchrotron radiation source

    International Nuclear Information System (INIS)

    Ibison, M.; Cheung, K.C.; Siu, K.; Hall, C.J.; Lewis, R.A.; Hufton, A.; Wilkinson, S.J.; Rogers, K.D.; Round, A.

    2005-01-01

    The Diffraction-Enhanced Imaging (DEI) system, which shares access to Beamline 7.6 on the Daresbury Synchrotron Radiation Source (SRS), is now in its third year of existence. The system was developed under a European Commission grant PHase Analyser SYstem (PHASY), won during the Fourth Framework. Typical applications continue to be the imaging of small biological specimens, using a beam of 12-17 keV after monochromation and up to 40 mm in width and 1-2 mm in height, although it is planned to investigate other materials as opportunity permits and time becomes available for more routine scientific use. Recent improvements have been made to the optical alignment procedure for setting up the station before imaging: a small laser device can now be set up to send a beam down the X-ray path through the four crystals, and a small photodiode, which has much better signal-to-noise characteristics than the ion chamber normally used for alignment, has been trailed successfully. A 3-D tomographic reconstruction capability has recently been developed and tested for DEI projection image sets, and will be applied to future imaging work on the SRS, in conjunction with volume visualization software. The next generation of DEI system, planned to operate at up to 60 keV on an SRS wiggler station, is in its design stage; it will feature much improved mechanics and mountings, especially for angular control, and a simplified alignment procedure to facilitate the necessary sharing of the SRS station

  1. Perfusion and diffusion MR imaging in enhancing malignant cerebral tumors

    International Nuclear Information System (INIS)

    Calli, Cem; Kitis, Omer; Yunten, Nilgun; Yurtseven, Taskin; Islekel, Sertac; Akalin, Taner

    2006-01-01

    Objective: Common contrast-enhancing malignant tumors of the brain are glioblastoma multiforme (GBMs), anaplastic astrocytomas (AAs), metastases, and lymphomas, all of which have sometimes similar conventional MRI findings. Our aim was to evaluate the role of perfusion MR imaging (PWI) and diffusion-weighted imaging (DWI) in the differentiation of these contrast-enhancing malignant cerebral tumors. Materials and methods: Forty-eight patients with contrast-enhancing and histologically proven brain tumors, 14 AAs, 17 GBMs, nine metastases, and eight lymphomas, were included in the study. All patients have undergone routine MR examination where DWI and PWI were performed in the same session. DWI was performed with b values of 0, 500, and 1000 mm 2 /s. Minimum ADC values (ADC min ) of each tumor was later calculated from ADC map images. PWI was applied using dynamic susceptibility contrast technique and maximum relative cerebral blood volume (rCBV max ) was calculated from each tumor, given in ratio with contralateral normal white matter. Comparisons of ADC min and rCBV max values with the histological types of the enhancing tumors were made with a one-way analysis of variance and Bonferroni test. A P value less than 0.05 indicated a statistically significant difference. Results: The ADC min values (mean ± S.D.) in GBMs, AAs, lymphomas, and metastases were 0.79 ± 0.21 (x10 -3 mm 2 /s), 0.75 ± 0.21 (x10 -3 mm 2 /s), 0.51 ± 0.09 (x10 -3 mm 2 /s), and 0.68 ± 0.11 (x10 -3 mm 2 /s), respectively. The difference in ADC min values were statistically significant between lymphomas and GBMs (P max ratio (mean ± S.D.) in GBMs were 6.33 ± 2.03, whereas it was 3.66 ± 1.79 in AAs, 2.33 ± 0.68 in lymphomas, and 4.45 ± 1.87 in metastases. These values were statistically different between GBMs and AAs (P min and rCBV max calculations, may aid routine MR imaging in the differentiation of common cerebral contrast-enhancing malignant tumors

  2. Photon-number correlation for quantum enhanced imaging and sensing

    Science.gov (United States)

    Meda, A.; Losero, E.; Samantaray, N.; Scafirimuto, F.; Pradyumna, S.; Avella, A.; Ruo-Berchera, I.; Genovese, M.

    2017-09-01

    In this review we present the potentialities and the achievements of the use of non-classical photon-number correlations in twin-beam states for many applications, ranging from imaging to metrology. Photon-number correlations in the quantum regime are easily produced and are rather robust against unavoidable experimental losses, and noise in some cases, if compared to the entanglement, where losing one photon can completely compromise the state and its exploitable advantages. Here, we will focus on quantum enhanced protocols in which only phase-insensitive intensity measurements (photon-number counting) are performed, which allow probing the transmission/absorption properties of a system, leading, for example, to innovative target detection schemes in a strong background. In this framework, one of the advantages is that the sources experimentally available emit a wide number of pair-wise correlated modes, which can be intercepted and exploited separately, for example by many pixels of a camera, providing a parallelism, essential in several applications, such as wide-field sub-shot-noise imaging and quantum enhanced ghost imaging. Finally, non-classical correlation enables new possibilities in quantum radiometry, e.g. the possibility of absolute calibration of a spatial resolving detector from the on-off single-photon regime to the linear regime in the same setup.

  3. Gd-DTPA enhanced MR imaging in Bell's palsy

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Kawamura, Yuji; Yanagihara, Naoaki; Sadamoto, Masanori; Sadamoto, Kazuhiko.

    1991-01-01

    Magnetic resonance imaging (MRI) was carried out in 27 patients with Bell's palsy. T1-weighted spin-echo images (TR500/TE25-34) were taken before and after the intravenous administration of Gd-DTPA (0.1 mmol/kg) with 0.5T superconductive MRI. There was significant enhancement at the geniculate ganglion and the horizontal segment of the involved facial nerve in 22 patients (81.5%) and at the vertical segment in 20 (74.1%). Enhancement at the meatal fundus was seen in only 4 patients (14.9%) and at the labyrinthine segment in 8 (29.6%). These results corroborate other evidence that the geniculate ganglion is involved most frequently in Bell's palsy. In addition, the enhancement of the proximal portion, i.e. the meatal fundus and the labyrinthine segment of the nerve, although not common, noted in this study may be important in the diagnosis and treatment of Bell's palsy. (author)

  4. Delayed enhancement of peripheral zone of neurofibromas at magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kurosaki, Y. [Dept. of Radiology, Inst. of Clinical Medicine, Univ. of Tsukuba (Japan); Kuramoto, K. [Dept. of Radiology, Inst. of Clinical Medicine, Univ. of Tsukuba (Japan); Itai, Y. [Dept. of Radiology, Inst. of Clinical Medicine, Univ. of Tsukuba (Japan)

    1996-02-01

    It is well known that bizonal histologic appearance characteristic of neurofibromas are reflected on magnetic resonance (MR) images. We report a case in which a delayed enhanced MR image showed that the entire mass enhanced homogeneously resulting in loss of zonal distinction on early enhanced MR image. (orig.)

  5. Standardised metrics for global surgical surveillance.

    Science.gov (United States)

    Weiser, Thomas G; Makary, Martin A; Haynes, Alex B; Dziekan, Gerald; Berry, William R; Gawande, Atul A

    2009-09-26

    Public health surveillance relies on standardised metrics to evaluate disease burden and health system performance. Such metrics have not been developed for surgical services despite increasing volume, substantial cost, and high rates of death and disability associated with surgery. The Safe Surgery Saves Lives initiative of WHO's Patient Safety Programme has developed standardised public health metrics for surgical care that are applicable worldwide. We assembled an international panel of experts to develop and define metrics for measuring the magnitude and effect of surgical care in a population, while taking into account economic feasibility and practicability. This panel recommended six measures for assessing surgical services at a national level: number of operating rooms, number of operations, number of accredited surgeons, number of accredited anaesthesia professionals, day-of-surgery death ratio, and postoperative in-hospital death ratio. We assessed the feasibility of gathering such statistics at eight diverse hospitals in eight countries and incorporated them into the WHO Guidelines for Safe Surgery, in which methods for data collection, analysis, and reporting are outlined.

  6. Visibility enhancement of color images using Type-II fuzzy membership function

    Science.gov (United States)

    Singh, Harmandeep; Khehra, Baljit Singh

    2018-04-01

    Images taken in poor environmental conditions decrease the visibility and hidden information of digital images. Therefore, image enhancement techniques are necessary for improving the significant details of these images. An extensive review has shown that histogram-based enhancement techniques greatly suffer from over/under enhancement issues. Fuzzy-based enhancement techniques suffer from over/under saturated pixels problems. In this paper, a novel Type-II fuzzy-based image enhancement technique has been proposed for improving the visibility of images. The Type-II fuzzy logic can automatically extract the local atmospheric light and roughly eliminate the atmospheric veil in local detail enhancement. The proposed technique has been evaluated on 10 well-known weather degraded color images and is also compared with four well-known existing image enhancement techniques. The experimental results reveal that the proposed technique outperforms others regarding visible edge ratio, color gradients and number of saturated pixels.

  7. Image enhancement of x-ray microscope using frequency spectrum analysis

    International Nuclear Information System (INIS)

    Li Wenjie; Chen Jie; Tian Jinping; Zhang Xiaobo; Liu Gang; Tian Yangchao; Liu Yijin; Wu Ziyu

    2009-01-01

    We demonstrate a new method for x-ray microscope image enhancement using frequency spectrum analysis. Fine sample characteristics are well enhanced with homogeneous visibility and better contrast from single image. This method is easy to implement and really helps to improve the quality of image taken by our imaging system.

  8. Image enhancement of x-ray microscope using frequency spectrum analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li Wenjie; Chen Jie; Tian Jinping; Zhang Xiaobo; Liu Gang; Tian Yangchao [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029 (China); Liu Yijin; Wu Ziyu, E-mail: wuzy@ihep.ac.c, E-mail: ychtian@ustc.edu.c [Institute of High Energy Physics, Chinese Academy of Science, Beijing 100049 (China)

    2009-09-01

    We demonstrate a new method for x-ray microscope image enhancement using frequency spectrum analysis. Fine sample characteristics are well enhanced with homogeneous visibility and better contrast from single image. This method is easy to implement and really helps to improve the quality of image taken by our imaging system.

  9. Brain Volume Estimation Enhancement by Morphological Image Processing Tools

    Directory of Open Access Journals (Sweden)

    Zeinali R.

    2017-12-01

    Full Text Available Background: Volume estimation of brain is important for many neurological applications. It is necessary in measuring brain growth and changes in brain in normal/ abnormal patients. Thus, accurate brain volume measurement is very important. Magnetic resonance imaging (MRI is the method of choice for volume quantification due to excellent levels of image resolution and between-tissue contrast. Stereology method is a good method for estimating volume but it requires to segment enough MRI slices and have a good resolution. In this study, it is desired to enhance stereology method for volume estimation of brain using less MRI slices with less resolution. Methods: In this study, a program for calculating volume using stereology method has been introduced. After morphologic method, dilation was applied and the stereology method enhanced. For the evaluation of this method, we used T1-wighted MR images from digital phantom in BrainWeb which had ground truth. Results: The volume of 20 normal brain extracted from BrainWeb, was calculated. The volumes of white matter, gray matter and cerebrospinal fluid with given dimension were estimated correctly. Volume calculation from Stereology method in different cases was made. In three cases, Root Mean Square Error (RMSE was measured. Case I with T=5, d=5, Case II with T=10, D=10 and Case III with T=20, d=20 (T=slice thickness, d=resolution as stereology parameters. By comparing these results of two methods, it is obvious that RMSE values for our proposed method are smaller than Stereology method. Conclusion: Using morphological operation, dilation allows to enhance the estimation volume method, Stereology. In the case with less MRI slices and less test points, this method works much better compared to Stereology method.

  10. Enhancing Single Molecule Imaging in Optofluidics and Microfluidics

    Directory of Open Access Journals (Sweden)

    Andreas E. Vasdekis

    2011-08-01

    Full Text Available Microfluidics and optofluidics have revolutionized high-throughput analysis and chemical synthesis over the past decade. Single molecule imaging has witnessed similar growth, due to its capacity to reveal heterogeneities at high spatial and temporal resolutions. However, both resolution types are dependent on the signal to noise ratio (SNR of the image. In this paper, we review how the SNR can be enhanced in optofluidics and microfluidics. Starting with optofluidics, we outline integrated photonic structures that increase the signal emitted by single chromophores and minimize the excitation volume. Turning then to microfluidics, we review the compatible functionalization strategies that reduce noise stemming from non-specific interactions and architectures that minimize bleaching and blinking.

  11. Magnetic resonance imaging of urinary bladder carcinoma: tumor staging and gadolinium contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Doringer, E.; Joos, H.; Forstner, R.; Schmoller, H.

    1992-01-01

    Forty-nine patients with urinary bladder carcinomas underwent pre-operative examinations using magnetic resonance (MR) imaging. The results of the MR examinations were correlated with the clinical-pathological findings following transurethral resection (TUR) and bimanual palpation (n = 47) or radical cystectomy (n = 2). The results of pre-contrast MR tumor staging (T1, T2), viewing stages Tis-T2 collectively, and subsequent to separate assessments of stages T3b-T4b, were correct 76.6% of the time. Gadolinium-DTPA (Gd-DTPA) contrast-enhanced examinations (pre-contrast T1 and after Gd-DTPA) showed a staging accuracy rate of 85.7%. T2-weighted images did not indicate any advantage when compared to T1-weighted images following Gd-DTPA. The signal intensity ratios of tumor/fat and tumor/muscle tissue were measured on T1-weighted pre-contrast images and following Gd-DTPA and then evaluated statistically, whereby the increased tumor signal intensity was statistically significant (Wilcoxon test, P < 0.01). Due to the relatively short examination time needed for T1-weighted images and the specific tumor enhancement, the administration of Gd-DTPA proves valuable in the diagnosis of bladder carcinomas. T2-weighted images are not necessary. (orig.)

  12. Diagnosis of thyroid multinodular goiter using diffraction-enhanced imaging

    International Nuclear Information System (INIS)

    Rocha, H.S.; Lopes, R.T.; Valiante, P.M.; Tirao, G.; Mazzaro, I.; Hoennicke, M.G.; Cusatis, C.; Giles, C.

    2005-01-01

    Diffraction-enhanced images (DEI) have been obtained using two silicon crystals. A first channel-cut silicon crystal using the Si(3 3 3) reflection is employed to reduce the divergence of the pre-monochromated Si(1 1 1) beam of the light line to 60 microradian (12 arcsec). A second channel-cut Si(3 3 3) crystal was used as a Bragg analyzer to obtain bright and dark field images by changing its angular position. This technique is ideally suited for soft-tissue imaging or objects with the same absorption coefficient interfaces. DEI was developed at the XRD-2 beamline at the Brazilian Synchrotron (LNLS) in Campinas-Brazil. Feasibility tests on acquired images, which allow the diagnosis of thyroid nodular goiter, were performed. This disease is ordinary. The tissue developed on the cervical area causes compression of the nearby structures and undesirable aesthetic deformities with worldwide distribution. DEI of the tissues were taken to observe their morphology and to compare with the microscopic analysis (histopathological). This technique allows cutting sections a hundred times thicker than conventional histological techniques allowing a complete vision of the disease morphology. DEI show details not clearly seen with conventional techniques

  13. HALO: a reconfigurable image enhancement and multisensor fusion system

    Science.gov (United States)

    Wu, F.; Hickman, D. L.; Parker, Steve J.

    2014-06-01

    Contemporary high definition (HD) cameras and affordable infrared (IR) imagers are set to dramatically improve the effectiveness of security, surveillance and military vision systems. However, the quality of imagery is often compromised by camera shake, or poor scene visibility due to inadequate illumination or bad atmospheric conditions. A versatile vision processing system called HALO™ is presented that can address these issues, by providing flexible image processing functionality on a low size, weight and power (SWaP) platform. Example processing functions include video distortion correction, stabilisation, multi-sensor fusion and image contrast enhancement (ICE). The system is based around an all-programmable system-on-a-chip (SoC), which combines the computational power of a field-programmable gate array (FPGA) with the flexibility of a CPU. The FPGA accelerates computationally intensive real-time processes, whereas the CPU provides management and decision making functions that can automatically reconfigure the platform based on user input and scene content. These capabilities enable a HALO™ equipped reconnaissance or surveillance system to operate in poor visibility, providing potentially critical operational advantages in visually complex and challenging usage scenarios. The choice of an FPGA based SoC is discussed, and the HALO™ architecture and its implementation are described. The capabilities of image distortion correction, stabilisation, fusion and ICE are illustrated using laboratory and trials data.

  14. Contour junctions defined by dynamic image deformations enhance perceptual transparency.

    Science.gov (United States)

    Kawabe, Takahiro; Nishida, Shin'ya

    2017-11-01

    The majority of work on the perception of transparency has focused on static images with luminance-defined contour junctions, but recent work has shown that dynamic image sequences with dynamic image deformations also provide information about transparency. The present study demonstrates that when part of a static image is dynamically deformed, contour junctions at which deforming and nondeforming contours are connected facilitate the deformation-based perception of a transparent layer. We found that the impression of a transparent layer was stronger when a dynamically deforming area was adjacent to static nondeforming areas than when presented alone. When contour junctions were not formed at the dynamic-static boundaries, however, the impression of a transparent layer was not facilitated by the presence of static surrounding areas. The effect of the deformation-defined junctions was attenuated when the spatial pattern of luminance contrast at the junctions was inconsistent with the perceived transparency related to luminance contrast, while the effect did not change when the spatial luminance pattern was consistent with it. In addition, the results showed that contour completions across the junctions were required for the perception of a transparent layer. These results indicate that deformation-defined junctions that involve contour completion between deforming and nondeforming regions enhance the perception of a transparent layer, and that the deformation-based perceptual transparency can be promoted by the simultaneous presence of appropriately configured luminance and contrast-other features that can also by themselves produce the sensation of perceiving transparency.

  15. Contrast-enhanced turbo spin-echo(TSE) T1-weighted imaging: improved contrast of enhancing lesions

    International Nuclear Information System (INIS)

    Choi, Sung Wook; Lee, Ghi Jai; Shim, Jae Chan; Lee, Young Ju; Jeong, Se Hyung; Kim, Ho kyun

    1997-01-01

    The purpose of this study was to evaluate the effect of contrast improvement of enhancing brain lesions by inherent magnetization transfer effect in turbo spin-echo(TSE)T1-weighted MR imaging. Twenty-six enhancing lesions of 19 patients were included in this study. Using a 1.0T superconductive MR unit, contrast-enhanced SE T1-weighted images(TR=3D600 msec, TE=3D12 msec, NEX=3D2, acquistition time=3D4min 27sec) and contrast-enhanced TSE T1-weighted images(TR=3D600 msec, TE=3D12, acquistition time=3D1min 44sec) were obtained. Signal intensities at enhancing lesions and adjacent white matter were measured in the same regions of both images. Signal-to-noise ratio(SNR) of enhancing lesions and adjacent white matter, and con-trast-to-noise ratio(CNR) and lesion-to-background contrast (LBC) of enhancing lesions were calculated and statistically analysed using the paired t-test. On contrast-enhanced TSE T1-weighted images, SNR of enhancing lesions and adjacent white matter decreased by 18%(p<0.01) and 32%(p<0.01), respectively, compared to contrast-enhanced SE T1-weighted images. CNR and LBC of enhancing lesions increased by 16%(p<0.05) and 66%(p<0.01), respectively. Due to the proposed inherent magnetization transfer effects in TSE imaging, con-trast-enhanced T1-weighted TSE images demonstrated a statistically significant improvement in CNR and LBC, compared to conventional contrast-enhanced T1-weighted SE images, and scan time was much shorter

  16. Diffraction enhanced X-ray imaging of mammals crystalline lens

    International Nuclear Information System (INIS)

    Antunes, A.; Hoennicke, M.G.; Safatle, A.M.V.; Cusatis, C.; Moraes Barros, P.S.; Morelhao, S.L.

    2005-01-01

    Crystalline lenses are transparent biological materials where the organization of the lens fibers can also be affected by changes at molecular level, and therefore the structure and morphology of the tissue can be correlated to the loss of transparency of the lens. In this work, internal structure of mammal lenses regarding the long-range ordering of the fibers are investigated by diffraction enhanced X-ray imaging (DEI) radiography. Moreover, DEI and absorption X-ray synchrotron radiographs for healthy and cataractous crystalline lenses are compared. Significant differences in healthy and cataractous crystalline lenses are observed

  17. Methods for Enhancing Geological Structures in Spectral Spatial Difference-Based on Remote-Sensing Image

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@In this paper, some image processing methods such as directional template (mask) matching enhancement, pseudocolor or false color enhancement, K-L transform enhancement are used to enhance a geological structure, one of important ore-controlling factors, shown in the remote-sensing images.This geological structure is regarded as image anomaly in the remote-sensing image, since considerable differences, based on the spatial spectral distribution pattern, in gray values (spectral), color tones and texture, are always present between the geological structure and background. Therefore,the enhancement of the geological structure in the remotesensing image is that of the spectral spatial difference.

  18. FRACTAL ANALYSIS OF TRABECULAR BONE: A STANDARDISED METHODOLOGY

    Directory of Open Access Journals (Sweden)

    Ian Parkinson

    2011-05-01

    Full Text Available A standardised methodology for the fractal analysis of histological sections of trabecular bone has been established. A modified box counting method has been developed for use on a PC based image analyser (Quantimet 500MC, Leica Cambridge. The effect of image analyser settings, magnification, image orientation and threshold levels, was determined. Also, the range of scale over which trabecular bone is effectively fractal was determined and a method formulated to objectively calculate more than one fractal dimension from the modified Richardson plot. The results show that magnification, image orientation and threshold settings have little effect on the estimate of fractal dimension. Trabecular bone has a lower limit below which it is not fractal (λ<25 μm and the upper limit is 4250 μm. There are three distinct fractal dimensions for trabecular bone (sectional fractals, with magnitudes greater than 1.0 and less than 2.0. It has been shown that trabecular bone is effectively fractal over a defined range of scale. Also, within this range, there is more than 1 fractal dimension, describing spatial structural entities. Fractal analysis is a model independent method for describing a complex multifaceted structure, which can be adapted for the study of other biological systems. This may be at the cell, tissue or organ level and compliments conventional histomorphometric and stereological techniques.

  19. Image enhancement by spatial frequency post-processing of images obtained with pupil filters

    Science.gov (United States)

    Estévez, Irene; Escalera, Juan C.; Stefano, Quimey Pears; Iemmi, Claudio; Ledesma, Silvia; Yzuel, María J.; Campos, Juan

    2016-12-01

    The use of apodizing or superresolving filters improves the performance of an optical system in different frequency bands. This improvement can be seen as an increase in the OTF value compared to the OTF for the clear aperture. In this paper we propose a method to enhance the contrast of an image in both its low and its high frequencies. The method is based on the generation of a synthetic Optical Transfer Function, by multiplexing the OTFs given by the use of different non-uniform transmission filters on the pupil. We propose to capture three images, one obtained with a clear pupil, one obtained with an apodizing filter that enhances the low frequencies and another one taken with a superresolving filter that improves the high frequencies. In the Fourier domain the three spectra are combined by using smoothed passband filters, and then the inverse transform is performed. We show that we can create an enhanced image better than the image obtained with the clear aperture. To evaluate the performance of the method, bar tests (sinusoidal tests) with different frequency content are used. The results show that a contrast improvement in the high and low frequencies is obtained.

  20. Neutron Activation Analysis with k0 standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    1998-01-01

    The objectives of the research are: (1) to develop and implement the k0 standardisation method for neutron activation analysis in close collaboration with scientific partners; (2) to exploit fully the inherent qualities of NAA such as accuracy, traceability, and multi-element offer complete services in health-physics measurements according to international quality standards, (2) to improve continuously these measurement techniques and to follow up international recommendations and legislation concerning the surveillance of workers; (3) to support and advise nuclear and non-nuclear industry on problems of radioactive contamination. Achievements in 1997 related to gamma spectrometry, whole-body counting, beta and alpha spectrometry, dosimetry, radon measurements, calibration, instrumentation, and neutron activation analysis are described

  1. An improved contrast enhancement algorithm for infrared images based on adaptive double plateaus histogram equalization

    Science.gov (United States)

    Li, Shuo; Jin, Weiqi; Li, Li; Li, Yiyang

    2018-05-01

    Infrared thermal images can reflect the thermal-radiation distribution of a particular scene. However, the contrast of the infrared images is usually low. Hence, it is generally necessary to enhance the contrast of infrared images in advance to facilitate subsequent recognition and analysis. Based on the adaptive double plateaus histogram equalization, this paper presents an improved contrast enhancement algorithm for infrared thermal images. In the proposed algorithm, the normalized coefficient of variation of the histogram, which characterizes the level of contrast enhancement, is introduced as feedback information to adjust the upper and lower plateau thresholds. The experiments on actual infrared images show that compared to the three typical contrast-enhancement algorithms, the proposed algorithm has better scene adaptability and yields better contrast-enhancement results for infrared images with more dark areas or a higher dynamic range. Hence, it has high application value in contrast enhancement, dynamic range compression, and digital detail enhancement for infrared thermal images.

  2. Choroidal vasculature characteristics based choroid segmentation for enhanced depth imaging optical coherence tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Qiang; Niu, Sijie [School of Computer Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); Yuan, Songtao; Fan, Wen, E-mail: fanwen1029@163.com; Liu, Qinghuai [Department of Ophthalmology, The First Affiliated Hospital with Nanjing Medical University, Nanjing 210029 (China)

    2016-04-15

    Purpose: In clinical research, it is important to measure choroidal thickness when eyes are affected by various diseases. The main purpose is to automatically segment choroid for enhanced depth imaging optical coherence tomography (EDI-OCT) images with five B-scans averaging. Methods: The authors present an automated choroid segmentation method based on choroidal vasculature characteristics for EDI-OCT images with five B-scans averaging. By considering the large vascular of the Haller’s layer neighbor with the choroid-sclera junction (CSJ), the authors measured the intensity ascending distance and a maximum intensity image in the axial direction from a smoothed and normalized EDI-OCT image. Then, based on generated choroidal vessel image, the authors constructed the CSJ cost and constrain the CSJ search neighborhood. Finally, graph search with smooth constraints was utilized to obtain the CSJ boundary. Results: Experimental results with 49 images from 10 eyes in 8 normal persons and 270 images from 57 eyes in 44 patients with several stages of diabetic retinopathy and age-related macular degeneration demonstrate that the proposed method can accurately segment the choroid of EDI-OCT images with five B-scans averaging. The mean choroid thickness difference and overlap ratio between the authors’ proposed method and manual segmentation drawn by experts were −11.43 μm and 86.29%, respectively. Conclusions: Good performance was achieved for normal and pathologic eyes, which proves that the authors’ method is effective for the automated choroid segmentation of the EDI-OCT images with five B-scans averaging.

  3. Choroidal vasculature characteristics based choroid segmentation for enhanced depth imaging optical coherence tomography images

    International Nuclear Information System (INIS)

    Chen, Qiang; Niu, Sijie; Yuan, Songtao; Fan, Wen; Liu, Qinghuai

    2016-01-01

    Purpose: In clinical research, it is important to measure choroidal thickness when eyes are affected by various diseases. The main purpose is to automatically segment choroid for enhanced depth imaging optical coherence tomography (EDI-OCT) images with five B-scans averaging. Methods: The authors present an automated choroid segmentation method based on choroidal vasculature characteristics for EDI-OCT images with five B-scans averaging. By considering the large vascular of the Haller’s layer neighbor with the choroid-sclera junction (CSJ), the authors measured the intensity ascending distance and a maximum intensity image in the axial direction from a smoothed and normalized EDI-OCT image. Then, based on generated choroidal vessel image, the authors constructed the CSJ cost and constrain the CSJ search neighborhood. Finally, graph search with smooth constraints was utilized to obtain the CSJ boundary. Results: Experimental results with 49 images from 10 eyes in 8 normal persons and 270 images from 57 eyes in 44 patients with several stages of diabetic retinopathy and age-related macular degeneration demonstrate that the proposed method can accurately segment the choroid of EDI-OCT images with five B-scans averaging. The mean choroid thickness difference and overlap ratio between the authors’ proposed method and manual segmentation drawn by experts were −11.43 μm and 86.29%, respectively. Conclusions: Good performance was achieved for normal and pathologic eyes, which proves that the authors’ method is effective for the automated choroid segmentation of the EDI-OCT images with five B-scans averaging.

  4. Half-unit weighted bilinear algorithm for image contrast enhancement in capsule endoscopy

    Science.gov (United States)

    Rukundo, Olivier

    2018-04-01

    This paper proposes a novel enhancement method based exclusively on the bilinear interpolation algorithm for capsule endoscopy images. The proposed method does not convert the original RBG image components to HSV or any other color space or model; instead, it processes directly RGB components. In each component, a group of four adjacent pixels and half-unit weight in the bilinear weighting function are used to calculate the average pixel value, identical for each pixel in that particular group. After calculations, groups of identical pixels are overlapped successively in horizontal and vertical directions to achieve a preliminary-enhanced image. The final-enhanced image is achieved by halving the sum of the original and preliminary-enhanced image pixels. Quantitative and qualitative experiments were conducted focusing on pairwise comparisons between original and enhanced images. Final-enhanced images have generally the best diagnostic quality and gave more details about the visibility of vessels and structures in capsule endoscopy images.

  5. Contrast-enhanced fast fluid-attenuated inversion recovery MR imaging in patients with brain tumors

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Na, Dong Gyu; Ryoo, Wook Jae; Byun Hong Sik; Yoon, Hye Kyung; Kim, Jong hyun

    2000-01-01

    To assess the feasibility of contrast-enhanced fast fluid-attenuated inversion recovery (fast FLAIR) MR imaging in patients with brain tumors. This study involved 31 patients with pathologically proven brain tumors and nine with clinically diagnosed metastases. In all patients, T2-weighted, fast FLAIR, images were visual contrast-enhanced T1-weighted MR images were obtained. Contrast-enhanced fast FLAIR images were visually compared with other MR sequences in terms of tumor conspicuity. In order to distinguish tumor and surrounding edema, contrast-enhanced fast FLAIR images were compared with fast FLAIR and T2-weighted images. The tumor-to- white matter contrast-to-noise ratios (CNRs), as demonstrated by T2-weighted, fast FLAIR, contrast-enhanced fast FLAIR and contrast-enhanced T1-weighted imaging, were quantitatively assessed and compared. For the visual assessment of tumor conspicuity, contrast-enhanced fast FLAIR image imaging superior to fast FLAIR in 60% of cases (24/40), and superior to T2-weighted in 70% (28/40). Contrast-enhanced fast FLAIR imaging was inferior to contrast-enhanced T1-weighted in 58% of cases (23/40). For distinguishing between tumor and surrounding edema, contrast-enhanced fast FLAIR imaging was superior to fast FLAIR or T2-weighted in 22 of 27 tumors with peritumoral edema (81%). Quantitatively, CNR was the highest on contrast-enhanced fast FLAIR image and the lowest on fast FLAIR. For the detection of leptomeningeal metastases, contrast-enhanced fast FLAIR was partially superior to contrast-enhanced T1-weighted imaging in two of three high-grade gliomas. Although contrast-enhanced fast FLAIR imaging should not be seen as a replacement for conventional modalities, it provides additional informaton for assessment of the extent of glial cell tumors and leptomeningeal metastases in patients with brain tumors. (author)

  6. Spectrally enhanced image resolution of tooth enamel surfaces

    Science.gov (United States)

    Zhang, Liang; Nelson, Leonard Y.; Berg, Joel H.; Seibel, Eric J.

    2012-01-01

    Short-wavelength 405 nm laser illumination of surface dental enamel using an ultrathin scanning fiber endoscope (SFE) produced enhanced detail of dental topography. The surfaces of human extracted teeth and artificial erosions were imaged with 405 nm, 444 nm, 532 nm, or 635 nm illumination lasers. The obtained images were then processed offline to compensate for any differences in the illumination beam diameters between the different lasers. Scattering and absorption coefficients for a Monte Carlo model of light propagation in dental enamel for 405 nm were scaled from published data at 532 nm and 633 nm. The value of the scattering coefficient used in the model was scaled from the coefficients at 532 nm and 633 nm by the inverse third power of wavelength. Simulations showed that the penetration depth of short-wavelength illumination is localized close to the enamel surface, while long-wavelength illumination travels much further and is backscattered from greater depths. Therefore, images obtained using short wavelength laser are not contaminated by the superposition of light reflected from enamel tissue at greater depths. Hence, the SFE with short-wavelength illumination may make it possible to visualize surface manifestations of phenomena such as demineralization, thus better aiding the clinician in the detection of early caries.

  7. Improvement of Fuzzy Image Contrast Enhancement Using Simulated Ergodic Fuzzy Markov Chains

    Directory of Open Access Journals (Sweden)

    Behrouz Fathi-Vajargah

    2014-01-01

    Full Text Available This paper presents a novel fuzzy enhancement technique using simulated ergodic fuzzy Markov chains for low contrast brain magnetic resonance imaging (MRI. The fuzzy image contrast enhancement is proposed by weighted fuzzy expected value. The membership values are then modified to enhance the image using ergodic fuzzy Markov chains. The qualitative performance of the proposed method is compared to another method in which ergodic fuzzy Markov chains are not considered. The proposed method produces better quality image.

  8. Oriented Edge-Based Feature Descriptor for Multi-Sensor Image Alignment and Enhancement

    Directory of Open Access Journals (Sweden)

    Myung-Ho Ju

    2013-10-01

    Full Text Available In this paper, we present an efficient image alignment and enhancement method for multi-sensor images. The shape of the object captured in a multi-sensor images can be determined by comparing variability of contrast using corresponding edges across multi-sensor image. Using this cue, we construct a robust feature descriptor based on the magnitudes of the oriented edges. Our proposed method enables fast image alignment by identifying matching features in multi-sensor images. We enhance the aligned multi-sensor images through the fusion of the salient regions from each image. The results of stitching the multi-sensor images and their enhancement demonstrate that our proposed method can align and enhance multi-sensor images more efficiently than previous methods.

  9. Imaging vascular function for early stage clinical trials using dynamic contrast-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M.O.; Orton, M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Cancer Research UK and EPSRC Cancer Imaging Centre, Sutton, Surrey (United Kingdom); Morgan, B. [Univ. of Leicester, College of Medicine, Biological Sciences and Psychology, Leicester (United Kingdom); Tofts, P.S. [Brighton and Sussex Medical School, Univ. of Sussex, Clinical Imaging Sciences Centre, Sussex (United Kingdom); Buckley, D.L. [University of Leeds, Division of Medical Physics, Leeds (United Kingdom); Huang, W. [Oregon Health and Science Univ., Advanced Imaging Research Centre, Portland, OR (United States); Horsfield, M.A. [Medical Physics Section, Leicester Royal Infirmary, Dept. of Cardiovascular Sciences, Leicester (United Kingdom); Chenevert, T.L. [Univ. of Michigan Health System, Ann Arbor, MI (United States); Collins, D.J. [Royal Marsden Hospital NHS Foundation Trust, Cancer Research UK and EPSRC Cancer Imaging Centre, Sutton, Surrey (United Kingdom); Jackson, A. [Univ. of Manchester, Wolfson Molecular Imaging Centre, Withington, Manchester, M20 3LJ (United Kingdom); Lomas, D. [Univ. of Cambridge, Dept. of Radiology, Cambridge (United Kingdom); Whitcher, B. [Unit 2 Greenways Business Park, Mango Solutions, Chippenham (United Kingdom); Clarke, L. [Cancer Imaging Program, Imaging Technology Development Branch, Rockville, MD (United States); Plummer, R. [Univ. of Newcastle Upon Tyne, The Medical School, Medical Oncology, Northern Inst. for Cancer Research, Newcastle Upon Tyne (United Kingdom); Judson, I. [Royal Marsden Hospital, Sutton, Surrey (United Kingdom); Jones, R. [Beatson West of Scotland Cancer Centre, Glasgow (United Kingdom); Alonzi, R. [Mount Vernon Cancer Centre, Northwood (United Kingdom); Brunner, T. [Gray Inst. for Radiation, Oncology and Biology, Oxford (United Kingdom); Koh, D.M. [Royal Marsden NHS Foundation Trust, Diagnostic Radiology, Sutton, Surrey (United Kingdom)] [and others

    2012-07-15

    Many therapeutic approaches to cancer affect the tumour vasculature, either indirectly or as a direct target. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has become an important means of investigating this action, both pre-clinically and in early stage clinical trials. For such trials, it is essential that the measurement process (i.e. image acquisition and analysis) can be performed effectively and with consistency among contributing centres. As the technique continues to develop in order to provide potential improvements in sensitivity and physiological relevance, there is considerable scope for between-centre variation in techniques. A workshop was convened by the Imaging Committee of the Experimental Cancer Medicine Centres (ECMC) to review the current status of DCE-MRI and to provide recommendations on how the technique can best be used for early stage trials. This review and the consequent recommendations are summarised here. (orig.)

  10. A fast combinatorial enhancement technique for earthquake damage identification based on remote sensing image

    Science.gov (United States)

    Dou, Aixia; Wang, Xiaoqing; Ding, Xiang; Du, Zecheng

    2010-11-01

    On the basis of the study on the enhancement methods of remote sensing images obtained after several earthquakes, the paper designed a new and optimized image enhancement model which was implemented by combining different single methods. The patterns of elementary model units and combined types of model were defined. Based on the enhancement model database, the algorithm of combinatorial model was brought out via C++ programming. The combined model was tested by processing the aerial remote sensing images obtained after 1976 Tangshan earthquake. It was proved that the definition and implementation of combined enhancement model can efficiently improve the ability and flexibility of image enhancement algorithm.

  11. Enhancing online timeline visualizations with events and images

    Science.gov (United States)

    Pandya, Abhishek; Mulye, Aniket; Teoh, Soon Tee

    2011-01-01

    The use of timeline to visualize time-series data is one of the most intuitive and commonly used methods, and is used for widely-used applications such as stock market data visualization, and tracking of poll data of election candidates over time. While useful, these timeline visualizations are lacking in contextual information of events which are related or cause changes in the data. We have developed a system that enhances timeline visualization with display of relevant news events and their corresponding images, so that users can not only see the changes in the data, but also understand the reasons behind the changes. We have also conducted a user study to test the effectiveness of our ideas.

  12. Magnetic iron oxide for contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Fahlvik, A.K.

    1991-05-01

    The main objective of this experimental work has been to study the biological fate and the contrast enhancing potential of a model preparation of magnetic iron oxide (MSM) after intravenous injection to rodents. This was achieved by: Studying in vitro contrast efficacy of various magnetic iron oxide preparations by relaxation analysis. Studying in vivo contrast efficacy of MSM by relaxation analysis and NMR imaging. Studying the biodistribution and bioelimination of MSM in independent experiments using relaxation analysis, radioactivity studies and histological techniques. Studying interactions of MSM with target cells and target organelles using ex vivo techniques. Based on the presented experimental study, the MSM model preparation of magnetic iron oxide seems to fulfill basic requirements of NMR contrast agents: efficient proton relaxation, specific in vivo distribution, and biological tolerance. 177 refs., 5 figs., 2 tabs

  13. Contrast-enhanced dynamic MR imaging in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Koenig, H.; Sieper, J.; Wolf, K.J.

    1989-01-01

    This paper reports on a study for the identification of different pannus formations. Twenty patients with advanced rheumatoid arthritis of the knee joint were examined with MR imaging primary to surgery. The authors used a 1.5-T Magnetom unit, a circular surface coil for signal detection, 0.1 mmol/kg of Gd-DTPA given as a bolus injection, fast low-angle shot (FLASH) sequence (TR, 30 msec; TE, 10 msec; 128 x 128 matrix; excitation angle, 70 degrees) repeated 30 times within 120 seconds, and a T1-weighted spin-echo sequence (Tr, 500 msec; TE, 22 msec) before and 2 minutes after contrast medium injection. Enhancement of pannus and joint effusion has been measured and standardized to muscle tissue

  14. MUSIC electromagnetic imaging with enhanced resolution for small inclusions

    International Nuclear Information System (INIS)

    Chen Xudong; Zhong Yu

    2009-01-01

    This paper investigates the influence of the test dipole on the resolution of the multiple signal classification (MUSIC) imaging method applied to the electromagnetic inverse scattering problem of determining the locations of a collection of small objects embedded in a known background medium. Based on the analysis of the induced electric dipoles in eigenstates, an algorithm is proposed to determine the test dipole that generates a pseudo-spectrum with enhanced resolution. The amplitudes in three directions of the optimal test dipole are not necessarily in phase, i.e., the optimal test dipole may not correspond to a physical direction in the real three-dimensional space. In addition, the proposed test-dipole-searching algorithm is able to deal with some special scenarios, due to the shapes and materials of objects, to which the standard MUSIC does not apply

  15. Content-adaptive Image Enhancement, Based on Sky and Grass Segmentation

    NARCIS (Netherlands)

    Zafarifar, B.; With, de P.H.N.

    2009-01-01

    Current TV image enhancement functions employ globally controlled settings. A more flexible system can be achieved if the global control is extended to incorporate semantic-level image content information. In this paper, we present a system that extends existing TV image enhancement functions with

  16. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    International Nuclear Information System (INIS)

    Olivieri, Laura; O'Brien, Kendall J.; Cross, Russell; Xue, Hui; Kellman, Peter; Hansen, Michael S.

    2016-01-01

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late-enhancement

  17. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    Energy Technology Data Exchange (ETDEWEB)

    Olivieri, Laura; O' Brien, Kendall J. [Children' s National Health System, Division of Cardiology, Washington, DC (United States); National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States); Cross, Russell [Children' s National Health System, Division of Cardiology, Washington, DC (United States); Xue, Hui; Kellman, Peter; Hansen, Michael S. [National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States)

    2016-06-15

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late-enhancement

  18. USE OF IMAGE ENHANCEMENT TECHNIQUES FOR IMPROVING REAL TIME FACE RECOGNITION EFFICIENCY ON WEARABLE GADGETS

    Directory of Open Access Journals (Sweden)

    MUHAMMAD EHSAN RANA

    2017-01-01

    Full Text Available The objective of this research is to study the effects of image enhancement techniques on face recognition performance of wearable gadgets with an emphasis on recognition rate.In this research, a number of image enhancement techniques are selected that include brightness normalization, contrast normalization, sharpening, smoothing, and various combinations of these. Subsequently test images are obtained from AT&T database and Yale Face Database B to investigate the effect of these image enhancement techniques under various conditions such as change of illumination and face orientation and expression.The evaluation of data, collected during this research, revealed that the effect of image pre-processing techniques on face recognition highly depends on the illumination condition under which these images are taken. It is revealed that the benefit of applying image enhancement techniques on face images is best seen when there is high variation of illumination among images. Results also indicate that highest recognition rate is achieved when images are taken under low light condition and image contrast is enhanced using histogram equalization technique and then image noise is reduced using median smoothing filter. Additionally combination of contrast normalization and mean smoothing filter shows good result in all scenarios. Results obtained from test cases illustrate up to 75% improvement in face recognition rate when image enhancement is applied to images in given scenarios.

  19. Enhancing the (MSLDIP) image steganographic method (ESLDIP method)

    Science.gov (United States)

    Seddik Saad, Al-hussien

    2011-10-01

    Message transmissions over the Internet still have data security problem. Therefore, secure and secret communication methods are needed for transmitting messages over the Internet. Cryptography scrambles the message so that it cannot be understood. However, it makes the message suspicious enough to attract eavesdropper's attention. Steganography hides the secret message within other innocuous-looking cover files (i.e. images, music and video files) so that it cannot be observed [1].The term steganography originates from the Greek root words "steganos'' and "graphein'' which literally mean "covered writing''. It is defined as the science that involves communicating secret data in an appropriate multimedia carrier, e.g., image, audio text and video files [3].Steganographic techniques allow one party to communicate information to another without a third party even knowing that the communication is occurring. The ways to deliver these "secret messages" vary greatly [3].Our proposed method called Enhanced SLDIP (ESLDIP). In which the maximmum hiding capacity (MHC) of proposed ESLDIP method is higher than the previously proposed MSLDIP methods and the PSNR of the ESLDIP method is higher than the MSLDIP PSNR values', which means that the image quality of the ESLDIP method will be better than MSLDIP method and the maximmum hiding capacity (MHC) also improved. The rest of this paper is organized as follows. In section 2, steganography has been discussed; lingo, carriers and types. In section 3, related works are introduced. In section 4, the proposed method will be discussed in details. In section 5, the simulation results are given and Section 6 concludes the paper.

  20. Standardised risk analysis as a communication tool

    International Nuclear Information System (INIS)

    Pluess, Ch.; Montanarini, M.; Bernauer, M.

    1998-01-01

    Full text of publication follows: several European countries require a risk analysis for the production, storage or transport a dangerous goods. This requirement imposes considerable administrative effort for some sectors of the industry. In order to minimize the effort of such studies, a generic risk analysis for an industrial sector proved to help. Standardised procedures can consequently be derived for efficient performance of the risk investigations. This procedure was successfully established in Switzerland for natural gas transmission lines and fossil fuel storage plants. The development process of the generic risk analysis involved an intense discussion between industry and authorities about methodology of assessment and the criteria of acceptance. This process finally led to scientific consistent modelling tools for risk analysis and to an improved communication from the industry to the authorities and the public. As a recent example, the Holland-Italy natural gas transmission pipeline is demonstrated, where this method was successfully employed. Although this pipeline traverses densely populated areas in Switzerland, using this established communication method, the risk problems could be solved without delaying the planning process. (authors)

  1. ELISA technique standardisation for human toxocariasis diagnosis

    International Nuclear Information System (INIS)

    Espinoza, Y.; Suarez, R.; Huiza, A.

    2003-01-01

    To standardise ELISA technique for toxocara canis human infection diagnosis by using excreted-secreted antigen prepared in our country. T. canis eggs were collected by incubation with formalin (2%) at 28 o C in order to obtain third stage larvae that were freed and incubated in RPMI at 37 o C for 7 days; the medium was replaced by a similar one and stored at -20 o C. Antigen was concentrated and protein dosage was made. Sera from patients with toxocariasis and newborns were used as positive and negative controls by ELISA technique, dilutions 1/4 to 1/1024. Polystyrene plates were sensitised with antigen in several concentrations and conjugated peroxidase with horseradish IgG, anti human IgG and substrate OPD were used. Absorbance was read with spectrophotometer (Multiskan plus labsystems) at 492 nm. Cut off point was determined by negative sera absorbencies arithmetic mean plus 3 standard deviations. Antigen concentration was 50 ug/mL, sera dilution 1/128, conjugate dilution 1/1000 with optical density above 0,241. ELISA technique for serologic diagnosis of human infection by toxocara canis could be used in epidemiological studies in our country. Its efficacy will be determined in future studies

  2. Age standardisation – an indigenous standard?

    Directory of Open Access Journals (Sweden)

    Simmonds Shirley

    2007-05-01

    Full Text Available Abstract The study of inequities in health is a critical component of monitoring government obligations to uphold the rights of Indigenous Peoples. In Aotearoa/New Zealand the indigenous Māori population has a substantially younger age structure than the non-indigenous population making it necessary to account for age differences when comparing population health outcomes. An age-standardised rate is a summary measure of a rate that a population would have if it had a standard age structure. Changing age standards have stimulated interest in the potential impact of population standards on disparities data and consequently on health policy. This paper compares the age structure of the Māori and non-Māori populations with two standard populations commonly used in New Zealand: Segi's world and WHO world populations. The performance of these standards in Māori and non-Māori mortality data was then measured against the use of the Māori population as a standard. It was found that the choice of population standard affects the magnitude of mortality rates, rate ratios and rate differences, the relative ranking of causes of death, and the relative width of confidence intervals. This in turn will affect the monitoring of trends in health outcomes and health policy decision-making. It is concluded that the choice of age standard has political implications and the development and utilisation of an international indigenous population standard should be considered.

  3. Minority Language Standardisation and the Role of Users

    Science.gov (United States)

    Lane, Pia

    2015-01-01

    Developing a standard for a minority language is not a neutral process; this has consequences for the status of the language and how the language users relate to the new standard. A potential inherent problem with standardisation is whether the language users themselves will accept and identify with the standard. When standardising minority…

  4. Remote Sensing Image Enhancement Based on Non-subsampled Shearlet Transform and Parameterized Logarithmic Image Processing Model

    Directory of Open Access Journals (Sweden)

    TAO Feixiang

    2015-08-01

    Full Text Available Aiming at parts of remote sensing images with dark brightness and low contrast, a remote sensing image enhancement method based on non-subsampled Shearlet transform and parameterized logarithmic image processing model is proposed in this paper to improve the visual effects and interpretability of remote sensing images. Firstly, a remote sensing image is decomposed into a low-frequency component and high frequency components by non-subsampled Shearlet transform.Then the low frequency component is enhanced according to PLIP (parameterized logarithmic image processing model, which can improve the contrast of image, while the improved fuzzy enhancement method is used to enhance the high frequency components in order to highlight the information of edges and details. A large number of experimental results show that, compared with five kinds of image enhancement methods such as bidirectional histogram equalization method, the method based on stationary wavelet transform and the method based on non-subsampled contourlet transform, the proposed method has advantages in both subjective visual effects and objective quantitative evaluation indexes such as contrast and definition, which can more effectively improve the contrast of remote sensing image and enhance edges and texture details with better visual effects.

  5. A Novel Retinex Algorithm and its Application to Fog-degraded Image Enhancement

    Directory of Open Access Journals (Sweden)

    Xueyou Hu

    2014-07-01

    Full Text Available Fog-degraded images enhancement is an important problem in the field of image enhancement and computer vision. To overcome the halo artifact, enhance the contrast and better preserve the color of original image, a novel Multi-Scale Retinex color image enhancement method is proposed in this paper. An adaptive anisotropic Gaussian filtering method and its principle are described. The orientation of the Gaussian filter long axes is determined according to the gradient orientation in the position. The procedure of algorithm is given in this paper and applied in the fog- degraded images enhancement. Finally, by comparison with histogram equalization and Multi-Scale Retinex method, the experimental results show that the proposed method can offer better performance in fog-degraded image enhancement.

  6. Contrast enhancement of bite mark images using the grayscale mixer in ACR in Photoshop®.

    Science.gov (United States)

    Evans, Sam; Noorbhai, Suzanne; Lawson, Zoe; Stacey-Jones, Seren; Carabott, Romina

    2013-05-01

    Enhanced images may improve bite mark edge definition, assisting forensic analysis. Current contrast enhancement involves color extraction, viewing layered images by channel. A novel technique, producing a single enhanced image using the grayscale mix panel within Adobe Camera Raw®, has been developed and assessed here, allowing adjustments of multiple color channels simultaneously. Stage 1 measured RGB values in 72 versions of a color chart image; eight sliders in Photoshop® were adjusted at 25% intervals, all corresponding colors affected. Stage 2 used a bite mark image, and found only red, orange, and yellow sliders had discernable effects. Stage 3 assessed modality preference between color, grayscale, and enhanced images; on average, the 22 survey participants chose the enhanced image as better defined for nine out of 10 bite marks. The study has shown potential benefits for this new technique. However, further research is needed before use in the analysis of bite marks. © 2013 American Academy of Forensic Sciences.

  7. Restoration and Enhancement of Underwater Images Based on Bright Channel Prior

    Directory of Open Access Journals (Sweden)

    Yakun Gao

    2016-01-01

    Full Text Available This paper proposed a new method of underwater images restoration and enhancement which was inspired by the dark channel prior in image dehazing field. Firstly, we proposed the bright channel prior of underwater environment. By estimating and rectifying the bright channel image, estimating the atmospheric light, and estimating and refining the transmittance image, eventually underwater images were restored. Secondly, in order to rectify the color distortion, the restoration images were equalized by using the deduced histogram equalization. The experiment results showed that the proposed method could enhance the quality of underwater images effectively.

  8. MR imaging of the early rheumatoid arthritis: usefulness of contrast enhanced fat suppressed SPGR imaging

    International Nuclear Information System (INIS)

    Kim, Sun Mi; Joo, Kyung Bin; Kim, Seong Tae; Hahm, Chang Kok

    1995-01-01

    To evaluate value of post-contrast 3-Dimensional fat suppressed Spoiled GRASS (FS SPGR) in detecting subtle bony erosion and tenosynovitis of hands and wrists due to early rheumatoid arthritis. Fourteen MR imagings of the hands and wrists were performed in 7 early rheumatoid arthritis without any abnormalities in plain radiography and in 7 healthy volunteers. All subjects underwent MR sequence of coronal 3D FS SPGR with and without contrast enhancement in 1.5T MR unit. We evaluated the number of the bony erosion and tenosynovitis respectively in pre-and post-contrast FS SPGR images. The abnormal enhancing areas were not demonstrated in 7 healthy volunteers. Seven patients had 25 bony erosions in pre-contrast FS SPGR and 52 bony erosions with tenosynovitis (n = 10) in post-contrast FS SPGR. Enhancing joint spaces were shown in 8 cases. Post-contrast FS SPGR was better than pre-contrast FS SPGR in the evaluation of early rheumatoid arthritis and is valuable as a baseline study

  9. MR imaging of the early rheumatoid arthritis: usefulness of contrast enhanced fat suppressed SPGR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Mi; Joo, Kyung Bin; Kim, Seong Tae; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate value of post-contrast 3-Dimensional fat suppressed Spoiled GRASS (FS SPGR) in detecting subtle bony erosion and tenosynovitis of hands and wrists due to early rheumatoid arthritis. Fourteen MR imagings of the hands and wrists were performed in 7 early rheumatoid arthritis without any abnormalities in plain radiography and in 7 healthy volunteers. All subjects underwent MR sequence of coronal 3D FS SPGR with and without contrast enhancement in 1.5T MR unit. We evaluated the number of the bony erosion and tenosynovitis respectively in pre-and post-contrast FS SPGR images. The abnormal enhancing areas were not demonstrated in 7 healthy volunteers. Seven patients had 25 bony erosions in pre-contrast FS SPGR and 52 bony erosions with tenosynovitis (n = 10) in post-contrast FS SPGR. Enhancing joint spaces were shown in 8 cases. Post-contrast FS SPGR was better than pre-contrast FS SPGR in the evaluation of early rheumatoid arthritis and is valuable as a baseline study.

  10. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    International Nuclear Information System (INIS)

    Parmar, Hemant; Sitoh, Y.-Y.; Anand, Pooja; Chua, Violet; Hui, Francis

    2006-01-01

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis

  11. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Hemant [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore) and Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: parurad@hotmail.com; Sitoh, Y.-Y. [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Anand, Pooja [Department of Neurology, National Neuroscience Institute, 11 Jalan Tan Tock Seng (Singapore); Chua, Violet [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Hui, Francis [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-04-15

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis.

  12. An Image Enhancement Method Using the Quantum-Behaved Particle Swarm Optimization with an Adaptive Strategy

    Directory of Open Access Journals (Sweden)

    Xiaoping Su

    2013-01-01

    Full Text Available Image enhancement techniques are very important to image processing, which are used to improve image quality or extract the fine details in degraded images. In this paper, two novel objective functions based on the normalized incomplete Beta transform function are proposed to evaluate the effectiveness of grayscale image enhancement and color image enhancement, respectively. Using these objective functions, the parameters of transform functions are estimated by the quantum-behaved particle swarm optimization (QPSO. We also propose an improved QPSO with an adaptive parameter control strategy. The QPSO and the AQPSO algorithms, along with genetic algorithm (GA and particle swarm optimization (PSO, are tested on several benchmark grayscale and color images. The results show that the QPSO and AQPSO perform better than GA and PSO for the enhancement of these images, and the AQPSO has some advantages over QPSO due to its adaptive parameter control strategy.

  13. Image enhancement using MCNP5 code and MATLAB in neutron radiography.

    Science.gov (United States)

    Tharwat, Montaser; Mohamed, Nader; Mongy, T

    2014-07-01

    This work presents a method that can be used to enhance the neutron radiography (NR) image for objects with high scattering materials like hydrogen, carbon and other light materials. This method used Monte Carlo code, MCNP5, to simulate the NR process and get the flux distribution for each pixel of the image and determines the scattered neutron distribution that caused image blur, and then uses MATLAB to subtract this scattered neutron distribution from the initial image to improve its quality. This work was performed before the commissioning of digital NR system in Jan. 2013. The MATLAB enhancement method is quite a good technique in the case of static based film neutron radiography, while in neutron imaging (NI) technique, image enhancement and quantitative measurement were efficient by using ImageJ software. The enhanced image quality and quantitative measurements were presented in this work. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Mammographic image quality in relation to positioning of the breast: A multicentre international evaluation of the assessment systems currently used, to provide an evidence base for establishing a standardised method of assessment.

    Science.gov (United States)

    Taylor, K; Parashar, D; Bouverat, G; Poulos, A; Gullien, R; Stewart, E; Aarre, R; Crystal, P; Wallis, M

    2017-11-01

    Optimum mammography positioning technique is necessary to maximise cancer detection. Current criteria for mammography appraisal lack reliability and validity with a need to develop a more objective system. We aimed to establish current international practice in assessing image quality (IQ), of screening mammograms then develop and validate a reproducible assessment tool. A questionnaire sent to centres in countries undertaking population screening identified practice, participants for an expert panel (EP) of radiologists/radiographers and a testing panel (TP) of radiographers. The EP developed category criteria and descriptors using a modified Delphi process to agree definitions. The EP scored 12 screening mammograms to test agreement then a main set of 178 cases. Weighted scores were derived for each descriptor enabling calculation of numerical parameters for each new category. The TP then scored the main set. Statistical analysis included ANOVA, t-tests and Kendall's coefficient. 11 centres in 8 countries responded forming an EP of 7 members and TP of 44 members. The EP showed moderate agreement when the scoring the mini test set W = 0.50 p < 0.001 and the main set W = 0.55 p < 0.001, 'posterior nipple line' being the most difficult descriptor. The weighted total scores differentiated the 4 new categories Perfect, Good, Adequate and Inadequate (p < 0.001). We have developed an assessment tool by Delphi consensus and weighted consensus criteria. We have successfully tabulated a range of numerical scores for each new category providing the first validated and reproducible mammography IQ scoring system. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  15. RGB Color Cube-Based Histogram Specification for Hue-Preserving Color Image Enhancement

    Directory of Open Access Journals (Sweden)

    Kohei Inoue

    2017-07-01

    Full Text Available A large number of color image enhancement methods are based on the methods for grayscale image enhancement in which the main interest is contrast enhancement. However, since colors usually have three attributes, including hue, saturation and intensity of more than only one attribute of grayscale values, the naive application of the methods for grayscale images to color images often results in unsatisfactory consequences. Conventional hue-preserving color image enhancement methods utilize histogram equalization (HE for enhancing the contrast. However, they cannot always enhance the saturation simultaneously. In this paper, we propose a histogram specification (HS method for enhancing the saturation in hue-preserving color image enhancement. The proposed method computes the target histogram for HS on the basis of the geometry of RGB (rad, green and blue color space, whose shape is a cube with a unit side length. Therefore, the proposed method includes no parameters to be set by users. Experimental results show that the proposed method achieves higher color saturation than recent parameter-free methods for hue-preserving color image enhancement. As a result, the proposed method can be used for an alternative method of HE in hue-preserving color image enhancement.

  16. Acetabular labral tears: contrast-enhanced MR imaging under continuous leg traction

    Energy Technology Data Exchange (ETDEWEB)

    Nishii, T. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Nakanishi, K. [Dept. of Radiology, Osaka Univ. Medical School, Suita (Japan); Sugano, N. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan); Naito, H. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Tamura, S. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Ochi, T. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan)

    1996-05-01

    The objective of this study was to evaluate the effects of continuous leg traction on contrast-enhanced MR imaging of the hip joint and to determine whether MR imaging under these conditions is useful for demonstrating acetabular labral tears. Nineteen hips underwent MR imaging with a T1-weighted spin-echo sequence, followed by MR imaging under continuous leg traction after intravenous injection of gadolinium-DTPA. Joint fluid enhancement and labral contour detection were evaluated. Eleven hips had labral tears shown by conventional arthrography, arthroscopy and macroscopic surgical findings. Assessment of labral tears by MR imaging was correlated with the diagnosis based on these standard techniques. Joint fluid enhancement was obtained in all hips at 30 min after injection. Superior and inferior labral surfaces were completely delineated in 1 hip on the unenhanced MR images, and in 7 and 13 hips, respectively, on the enhanced images under traction. The enhanced images under traction depicted 9 of the 11 labral tears. Comparison between the unenhanced image and the enhanced image under traction avoided mistaking undercutting of the labrum for a tear in 4 hips. Contrast-enhanced MR imaging under traction was valuable for detecting labral tears non-invasively and without radiation. Follow-up examinations using this method in patients with acetabular dysplasia can help to clarify the natural course of labral disorders and enable better treatment planning. (orig./MG)

  17. The standardised copy of pentagons test

    Directory of Open Access Journals (Sweden)

    Terzoglou Vassiliki A

    2011-04-01

    Full Text Available Abstract Background The 'double-diamond copy' task is a simple paper and pencil test part of the Bender-Gestalt Test and the Mini Mental State Examination (MMSE. Although it is a widely used test, its method of scoring is crude and its psychometric properties are not adequately known. The aim of the present study was to develop a sensitive and reliable method of administration and scoring. Methods The study sample included 93 normal control subjects (53 women and 40 men aged 35.87 ± 12.62 and 127 patients suffering from schizophrenia (54 women and 73 men aged 34.07 ± 9.83. Results The scoring method was based on the frequencies of responses of healthy controls and proved to be relatively reliable with Cronbach's α equal to 0.61, test-retest correlation coefficient equal to 0.41 and inter-rater reliability equal to 0.52. The factor analysis produced two indices and six subscales of the Standardised Copy of Pentagons Test (SCPT. The total score as well as most of the individual items and subscales distinguished between controls and patients. The discriminant function correctly classified 63.44% of controls and 75.59% of patients. Discussion The SCPT seems to be a satisfactory, reliable and valid instrument, which is easy to administer, suitable for use in non-organic psychiatric patients and demands minimal time. Further research is necessary to test its psychometric properties and its usefulness and applications as a neuropsychological test.

  18. Image enhancement in photoemission electron microscopy by means of imaging time-of-flight analysis

    International Nuclear Information System (INIS)

    Oelsner, A.; Krasyuk, A.; Fecher, G.H.; Schneider, C.M.; Schoenhense, G.

    2004-01-01

    Photoemission electron microscopy (PEEM) is widely used in combination with synchrotron sources as a powerful tool to observe chemical and magnetic properties of metal and semiconductor surfaces. Presently, the resolution limit of these instruments using soft-X-ray excitation is limited to about 50 nm, because of the chromatic aberration of the electron optics used. Various sophisticated approaches have thus been reported for enhancing the spatial resolution in photoemission electron microscopy. This work demonstrates the use of a simple imaging energy filter based on electron time-of-flight (ToF) selection. The spatial resolution could be improved dramatically, even though the instrument was optimized using a rather large contrast aperture of 50 μm. A special (x, y, t)-resolving delayline detector was used as the imaging unit of this ToF-PEEM. It is operated in phase with the time structure of the synchrotron source, cutting time intervals from the raw image-forming data set in order to reduce the electron energy width contributing to the final images

  19. Automatic segmentation of the choroid in enhanced depth imaging optical coherence tomography images.

    Science.gov (United States)

    Tian, Jing; Marziliano, Pina; Baskaran, Mani; Tun, Tin Aung; Aung, Tin

    2013-03-01

    Enhanced Depth Imaging (EDI) optical coherence tomography (OCT) provides high-definition cross-sectional images of the choroid in vivo, and hence is used in many clinical studies. However, the quantification of the choroid depends on the manual labelings of two boundaries, Bruch's membrane and the choroidal-scleral interface. This labeling process is tedious and subjective of inter-observer differences, hence, automatic segmentation of the choroid layer is highly desirable. In this paper, we present a fast and accurate algorithm that could segment the choroid automatically. Bruch's membrane is detected by searching the pixel with the biggest gradient value above the retinal pigment epithelium (RPE) and the choroidal-scleral interface is delineated by finding the shortest path of the graph formed by valley pixels using Dijkstra's algorithm. The experiments comparing automatic segmentation results with the manual labelings are conducted on 45 EDI-OCT images and the average of Dice's Coefficient is 90.5%, which shows good consistency of the algorithm with the manual labelings. The processing time for each image is about 1.25 seconds.

  20. Enhanced Imaging of Building Interior for Portable MIMO Through-the-wall Radar

    Science.gov (United States)

    Song, Yongping; Zhu, Jiahua; Hu, Jun; Jin, Tian; Zhou, Zhimin

    2018-01-01

    Portable multi-input multi-output (MIMO) radar system is able to imaging the building interior through aperture synthesis. However, significant grating lobes are invoked in the directly imaging results, which may deteriorate the imaging quality of other targets and influence the detail information extraction of imaging scene. In this paper, a two-stage coherence factor (CF) weighting method is proposed to enhance the imaging quality. After obtaining the sub-imaging results of each spatial sampling position using conventional CF approach, a window function is employed to calculate the proposed “enhanced CF” adaptive to the spatial variety effect behind the wall for the combination of these sub-images. The real data experiment illustrates the better performance of proposed method on grating lobes suppression and imaging quality enhancement compare to the traditional radar imaging approach.

  1. Tolerance of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis

    Science.gov (United States)

    Rianti, R. A.; Priaminiarti, M.; Syahraini, S. I.

    2017-08-01

    Image enhancement brightness and contrast can be adjusted on lateral cephalometric digital radiographs to improve image quality and anatomic landmarks for measurement by Steiner analysis. To determine the limit value for adjustments of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis. Image enhancement brightness and contrast were adjusted on 100 lateral cephalometric radiography in 10-point increments (-30, -20, -10, 0, +10, +20, +30). Steiner analysis measurements were then performed by two observers. Reliabilities were tested by the Interclass Correlation Coefficient (ICC) and significance tested by ANOVA or the Kruskal Wallis test. No significant differences were detected in lateral cephalometric analysis measurements following adjustment of the image enhancement brightness and contrast. The limit value of adjustments of the image enhancement brightness and contrast associated with incremental 10-point changes (-30, -20, -10, 0, +10, +20, +30) does not affect the results of Steiner analysis.

  2. Image enhancement using MCNP5 code and MATLAB in neutron radiography

    International Nuclear Information System (INIS)

    Tharwat, Montaser; Mohamed, Nader; Mongy, T.

    2014-01-01

    This work presents a method that can be used to enhance the neutron radiography (NR) image for objects with high scattering materials like hydrogen, carbon and other light materials. This method used Monte Carlo code, MCNP5, to simulate the NR process and get the flux distribution for each pixel of the image and determines the scattered neutron distribution that caused image blur, and then uses MATLAB to subtract this scattered neutron distribution from the initial image to improve its quality. This work was performed before the commissioning of digital NR system in Jan. 2013. The MATLAB enhancement method is quite a good technique in the case of static based film neutron radiography, while in neutron imaging (NI) technique, image enhancement and quantitative measurement were efficient by using ImageJ software. The enhanced image quality and quantitative measurements were presented in this work. - Highlights: • This work is applicable for static based film neutron radiography and digital neutron imaging. • MATLAB is a useful tool for imaging enhancement in radiographic film. • Advanced imaging processing is available in the ETRR-2 for imaging processing and data extraction. • The digital imaging system is suitable for complex shapes and sizes, while MATLAB technique is suitable for simple shapes and sizes. • Quantitative measurements are available

  3. Basics concepts and clinical applications of oxygen-enhanced MR imaging

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto

    2007-01-01

    Oxygen-enhanced MR imaging is a new technique, and its physiological significance has not yet been fully elucidated. This review article covers (1) the theory of oxygen enhancement and its relationship with respiratory physiology; (2) design for oxygen-enhanced MR imaging sequencing; (3) a basic study of oxygen-enhanced MR imaging in animal models and humans; (4) a clinical study of oxygen-enhanced MR imaging; and (5) a comparison of advantages and disadvantages of this technique with those of hyperpolarized noble gas MR ventilation imaging. Oxygen-enhanced MR imaging provides not only the ventilation-related, but also respiration-related information. Oxygen-enhanced MR imaging has the potential to replace nuclear medicine studies for the identification of regional pulmonary function, and many investigators are now attempting to adapt this technique for routine clinical studies. We believe that further basic studies as well as clinical applications of this new technique will define the real significance of oxygen-enhanced MR imaging for the future of pulmonary functional imaging and its usefulness for diagnostic radiology and pulmonary medicine

  4. Enhancing Image Retrieval System Using Content Based Search ...

    African Journals Online (AJOL)

    The output shows more efficiency in retrieval because instead of performing the search on the entire image database, the image category option directs the retrieval engine to the specified category. Also, there is provision to update or modify the different image categories in the image database as need arise. Keywords: ...

  5. Assessment of arterial hypervascularity of hepatocellular carcinoma: comparison of contrast-enhanced US and gadoxetate disodium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Sugimoto, Katsutoshi; Moriyasu, Fuminori; Taira, Junichi; Imai, Yasuharu; Shiraishi, Junji; Saito, Kazuhiro; Saguchi, Toru

    2012-01-01

    To compare contrast-enhanced (CE) ultrasound with gadoxetate disodium-enhanced magnetic resonance (MR) imaging in the assessment of arterial hypervascularity of hepatocellular carcinoma (HCC) and dysplastic nodule (DN), with CT during hepatic arteriography (CTHA) as the reference standard. This study included 54 consecutively diagnosed patients, with 57 histologically confirmed HCCs and 3 DNs (high-grade). All patients underwent CE ultrasound, gadoxetate disodium-enhanced MR imaging and CTHA. Two trained diagnostic radiologists interpreted the CTHA images and rated the degree of intratumoral arterial vascularity by consensus using a five-point confidence scale as the reference standard. In the observer study, the degrees of vascularity on CE ultrasound and gadoxetate disodium-enhanced MR images were qualitatively analysed by four independent readers using a five-point confidence scale. Diagnostic accuracy was analysed by receiver-operating characteristic (ROC) analysis. The diagnostic accuracies of the average area under the ROC curve (AUC) were significantly greater with CE ultrasound (average AUC: 0.94; 95% confidence interval [CI]: 0.88-1.00) than with gadoxetate disodium-enhanced MR imaging (average AUC 0.84, 95% CI 0.74-0.93, P = 0.0014). Contrast-enhanced ultrasound yields a significantly higher AUC value than gadoxetate disodium-enhanced MR imaging in the assessment of arterial hypervascularity of HCC and DN. Key Points circle Arterial hypervascularity is an important feature determining treatment options in hepatocellular carcinoma. circle It can be assessed by contrast-enhanced (CE) ultrasound or magnetic resonance (MR) imaging. circle CE ultrasound was more accurate than Gd-EOB-DTPA MRI in assessing intratumoral vascularity. circle Hypovascular hepatic nodules should be further investigated using CE ultrasound. (orig.)

  6. Counterfeiting in performance- and image-enhancing drugs.

    Science.gov (United States)

    Graham, Michael R; Ryan, Paul; Baker, Julien S; Davies, Bruce; Thomas, Non-Eleri; Cooper, Stephen-Mark; Evans, Peter; Easmon, Sue; Walker, Christopher J; Cowan, David; Kicman, Andrew T

    2009-03-01

    The current drastic escalation in obesity may be contributing to the exponential rise in drugs used for image enhancement. Drugs such as anabolic-androgenic steroids (AAS) are perceived as a viable method of achieving a perfect physique. They are also the most widely abused drugs in sport. The Internet has encouraged the abuse of expensive drugs, particularly human growth hormone (hGH), resulting in increased importation for personal use. The substantial increase in this market has opened up avenues for counterfeiting, estimated as a multi-million pound business. The acute adverse effects from contaminated vials may result in a variety of pathologies including communicable diseases. In 2007, in the UK, a series of intramuscular abscesses, requiring surgical treatment, led us to study samples obtained from the underground market. The analysis of 38 parenteral samples and 19 oral samples of tablets was performed by a World Anti-Doping Agency (WADA) accredited laboratory, in an attempt to establish the extent of available counterfeit products. Fifty-three per cent (20) of the injectable AAS esters and 21% (4) of the oral tablets were counterfeit. Culture and sensitivity revealed the presence of skin commensal organisms, which may have contributed to the development of the abscesses. Users of AAS and hGH for sport, including bodybuilding, are currently risking their health because of counterfeit and poorly controlled products. Copyright 2009 John Wiley & Sons, Ltd.

  7. Present and future status of flexible spectral imaging color enhancement and blue laser imaging technology.

    Science.gov (United States)

    Osawa, Hiroyuki; Yamamoto, Hironori

    2014-01-01

    The usefulness of flexible spectral imaging color enhancement (FICE) has been reported for evaluating the esophagus, stomach, and small and large intestine. Higher contrast is shown between cancer and the surrounding mucosa in the esophagus and stomach and may facilitate the detection of gastric cancers missed by white light imaging alone. The surface patterns of gastric mucosa are clearly visualized in non-malignant areas but are irregular and blurred in malignant areas, leading to clear demarcation. Capsule endoscopy with FICE detects angiodysplasia and erosions of the small intestine. The surface and vascular pattern with FICE is useful for the differential diagnosis of colorectal polyps. However, FICE remains somewhat poor at visualizing mucosal microvasculature on a tumor surface. Narrow-band imaging (NBI) is dark in observing whole gastric mucosa and poor at visualizing mucosal microstructure. Blue laser imaging (BLI) has the potential to resolve these limitations. Narrow-band laser light combined with white light shows irregular microvessels on both differentiated and undifferentiated gastric cancer similar to those using NBI. In addition, irregular surface patterns including minute white zones are clearly seen on the uneven surface of differentiated lesions, resulting in exclusion of undifferentiated lesions. Using both distant and close-up views, a high contrast between green intestinal metaplasia and brown gastric cancer may lead to early detection of gastric cancers and determination of a demarcation line. BLI produces high-contrast images in esophageal cancer with clear vision of intrapapillary capillary loops and also predicts the histopathological diagnosis and depth of invasion in colorectal neoplasms. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  8. Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging.

    Science.gov (United States)

    Kaufmann, Sascha; Sauter, Alexander; Spira, Daniel; Gatidis, Sergios; Ketelsen, Dominik; Heuschmid, Martin; Claussen, Claus D; Thomas, Christoph

    2013-05-01

    To measure and compare the objective image quality of true noncontrast (TNC) images with virtual noncontrast (VNC) images acquired by tin-filter-enhanced, dual-source, dual-energy computed tomography (DECT) of upper abdomen. Sixty-three patients received unenhanced abdominal CT and enhanced abdominal DECT (100/140 kV with tin filter) in portal-venous phase. VNC images were calculated from the DECT datasets using commercially available software. The mean attenuation of relevant tissues and image quality were compared between the TNC and VNC images. Image quality was rated objectively by measuring image noise and the sharpness of object edges using custom-designed software. Measurements were compared using Student two-tailed t-test. Correlation coefficients for tissue attenuation measurements between TNC and VNC were calculated and the relative deviations were illustrated using Bland-Altman plots. Mean attenuation differences between TNC and VNC (HUTNC - HUVNC) image sets were as follows: right liver lobe -4.94 Hounsfield units (HU), left liver lobe -3.29 HU, vena cava -2.19 HU, spleen -7.46 HU, pancreas 1.29 HU, fat -11.14 HU, aorta 1.29 HU, bone marrow 36.83 HU (all P VNC and TNC series were observed for liver, vena portae, kidneys, pancreas, muscle and bone marrow (Pearson's correlation coefficient ≥0.75). Mean image noise was significantly higher in TNC images (P VNC and TNC images (P = .19). The Hounsfield units in VNC images closely resemble TNC images in the majority of the organs of the upper abdomen (kidneys, liver, pancreas). In spleen and fat, Hounsfield numbers in VNC images are tend to be higher than in TNC images. VNC images show a low image noise and satisfactory edge sharpness. Other criteria of image quality and the depiction of certain lesions need to be evaluated additionally. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  9. Contrast-enhanced magnetic resonance angiography in carotid artery disease: does automated image registration improve image quality?

    International Nuclear Information System (INIS)

    Menke, Jan; Larsen, Joerg

    2009-01-01

    Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive imaging alternative to digital subtraction angiography (DSA) for patients with carotid artery disease. In DSA, image quality can be improved by shifting the mask image if the patient has moved during angiography. This study investigated whether such image registration may also help to improve the image quality of carotid MRA. Data from 370 carotid MRA examinations of patients likely to have carotid artery disease were prospectively collected. The standard nonregistered MRAs were compared to automatically linear, affine and warp registered MRA by using three image quality parameters: the vessel detection probability (VDP) in maximum intensity projection (MIP) images, contrast-to-noise ratio (CNR) in MIP images, and contrast-to-noise ratio in three-dimensional image volumes. A body shift of less than 1 mm occurred in 96.2% of cases. Analysis of variance revealed no significant influence of image registration and body shift on image quality (p > 0.05). In conclusion, standard contrast-enhanced carotid MRA usually requires no image registration to improve image quality and is generally robust against any naturally occurring body shift. (orig.)

  10. Noninvasive enhanced mid-IR imaging of breast cancer development in vivo

    Science.gov (United States)

    Case, Jason R.; Young, Madison A.; Dréau, D.; Trammell, Susan R.

    2015-11-01

    Lumpectomy coupled with radiation therapy and/or chemotherapy is commonly used to treat breast cancer patients. We are developing an enhanced thermal IR imaging technique that has the potential to provide real-time imaging to guide tissue excision during a lumpectomy by delineating tumor margins. This enhanced thermal imaging method is a combination of IR imaging (8 to 10 μm) and selective heating of blood (˜0.5°C) relative to surrounding water-rich tissue using LED sources at low powers. Postacquisition processing of these images highlights temporal changes in temperature and the presence of vascular structures. In this study, fluorescent, standard thermal, and enhanced thermal imaging modalities, as well as physical caliper measurements, were used to monitor breast cancer tumor volumes over a 30-day study period in 19 mice implanted with 4T1-RFP tumor cells. Tumor volumes calculated from fluorescent imaging follow an exponential growth curve for the first 22 days of the study. Cell necrosis affected the tumor volume estimates based on the fluorescent images after day 22. The tumor volumes estimated from enhanced thermal imaging, standard thermal imaging, and caliper measurements all show exponential growth over the entire study period. A strong correlation was found between tumor volumes estimated using fluorescent imaging, standard IR imaging, and caliper measurements with enhanced thermal imaging, indicating that enhanced thermal imaging monitors tumor growth. Further, the enhanced IR images reveal a corona of bright emission along the edges of the tumor masses associated with the tumor margin. In the future, this IR technique might be used to estimate tumor margins in real time during surgical procedures.

  11. Noise reduction and image enhancement using a hardware implementation of artificial neural networks

    Science.gov (United States)

    David, Robert; Williams, Erin; de Tremiolles, Ghislain; Tannhof, Pascal

    1999-03-01

    In this paper, we present a neural based solution developed for noise reduction and image enhancement using the ZISC, an IBM hardware processor which implements the Restricted Coulomb Energy algorithm and the K-Nearest Neighbor algorithm. Artificial neural networks present the advantages of processing time reduction in comparison with classical models, adaptability, and the weighted property of pattern learning. The goal of the developed application is image enhancement in order to restore old movies (noise reduction, focus correction, etc.), to improve digital television images, or to treat images which require adaptive processing (medical images, spatial images, special effects, etc.). Image results show a quantitative improvement over the noisy image as well as the efficiency of this system. Further enhancements are being examined to improve the output of the system.

  12. Gd-DTPA-enhanced MR imaging of avascular necrosis of the hip

    International Nuclear Information System (INIS)

    Van de Berg, B.; Malghem, J.; Noel, H.; Maldague, B.

    1990-01-01

    This paper evaluates the interest of Gd-DTPA-enhanced MR imaging in the diagnosis of avascular necrosis (AVN) of the hip. MR imaging of 10 patients with various stages of AVN of the femoral head (14 abnormal hips) was performed (1.5-T Gyroscan). T1-weighted images before and after contrast injection and T2-weighted images were obtained in two planes. MR images were compared with pathologic findings in six femoral head specimens (total hip replacement). In the early stages of AVN (Mitchell classes A and B), a peripheral band of contrast-enhanced tissue appears on T1-weighted images after Gd-DTPA injection, mimicking the double line seen on T2-weighted images. In later stages (class C and D), the sequestrated segments, appearing hypointense on T1-weighted images, usually show a significant signal intensity enhancement after Gd-DTPA injection. The truly avascular areas may be limited to a band of thickened subchondral bone

  13. Enhancement method for rendered images of home decoration based on SLIC superpixels

    Science.gov (United States)

    Dai, Yutong; Jiang, Xiaotong

    2018-04-01

    Rendering technology has been widely used in the home decoration industry in recent years for images of home decoration design. However, due to the fact that rendered images of home decoration design rely heavily on the parameters of renderer and the lights of scenes, most rendered images in this industry require further optimization afterwards. To reduce workload and enhance rendered images automatically, an algorithm utilizing neural networks is proposed in this manuscript. In addition, considering few extreme conditions such as strong sunlight and lights, SLIC superpixels based segmentation is used to choose out these bright areas of an image and enhance them independently. Finally, these chosen areas are merged with the entire image. Experimental results show that the proposed method effectively enhances the rendered images when compared with some existing algorithms. Besides, the proposed strategy is proven to be adaptable especially to those images with obvious bright parts.

  14. Integrated interpretation of overlapping AEM datasets achieved through standardisation

    Science.gov (United States)

    Sørensen, Camilla C.; Munday, Tim; Heinson, Graham

    2015-12-01

    Numerous airborne electromagnetic surveys have been acquired in Australia using a variety of systems. It is not uncommon to find two or more surveys covering the same ground, but acquired using different systems and at different times. Being able to combine overlapping datasets and get a spatially coherent resistivity-depth image of the ground can assist geological interpretation, particularly when more subtle geophysical responses are important. Combining resistivity-depth models obtained from the inversion of airborne electromagnetic (AEM) data can be challenging, given differences in system configuration, geometry, flying height and preservation or monitoring of system acquisition parameters such as waveform. In this study, we define and apply an approach to overlapping AEM surveys, acquired by fixed wing and helicopter time domain electromagnetic (EM) systems flown in the vicinity of the Goulds Dam uranium deposit in the Frome Embayment, South Australia, with the aim of mapping the basement geometry and the extent of the Billeroo palaeovalley. Ground EM soundings were used to standardise the AEM data, although results indicated that only data from the REPTEM system needed to be corrected to bring the two surveys into agreement and to achieve coherent spatial resistivity-depth intervals.

  15. An Adaptive Image Enhancement Technique by Combining Cuckoo Search and Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Zhiwei Ye

    2015-01-01

    Full Text Available Image enhancement is an important procedure of image processing and analysis. This paper presents a new technique using a modified measure and blending of cuckoo search and particle swarm optimization (CS-PSO for low contrast images to enhance image adaptively. In this way, contrast enhancement is obtained by global transformation of the input intensities; it employs incomplete Beta function as the transformation function and a novel criterion for measuring image quality considering three factors which are threshold, entropy value, and gray-level probability density of the image. The enhancement process is a nonlinear optimization problem with several constraints. CS-PSO is utilized to maximize the objective fitness criterion in order to enhance the contrast and detail in an image by adapting the parameters of a novel extension to a local enhancement technique. The performance of the proposed method has been compared with other existing techniques such as linear contrast stretching, histogram equalization, and evolutionary computing based image enhancement methods like backtracking search algorithm, differential search algorithm, genetic algorithm, and particle swarm optimization in terms of processing time and image quality. Experimental results demonstrate that the proposed method is robust and adaptive and exhibits the better performance than other methods involved in the paper.

  16. An adaptive image enhancement technique by combining cuckoo search and particle swarm optimization algorithm.

    Science.gov (United States)

    Ye, Zhiwei; Wang, Mingwei; Hu, Zhengbing; Liu, Wei

    2015-01-01

    Image enhancement is an important procedure of image processing and analysis. This paper presents a new technique using a modified measure and blending of cuckoo search and particle swarm optimization (CS-PSO) for low contrast images to enhance image adaptively. In this way, contrast enhancement is obtained by global transformation of the input intensities; it employs incomplete Beta function as the transformation function and a novel criterion for measuring image quality considering three factors which are threshold, entropy value, and gray-level probability density of the image. The enhancement process is a nonlinear optimization problem with several constraints. CS-PSO is utilized to maximize the objective fitness criterion in order to enhance the contrast and detail in an image by adapting the parameters of a novel extension to a local enhancement technique. The performance of the proposed method has been compared with other existing techniques such as linear contrast stretching, histogram equalization, and evolutionary computing based image enhancement methods like backtracking search algorithm, differential search algorithm, genetic algorithm, and particle swarm optimization in terms of processing time and image quality. Experimental results demonstrate that the proposed method is robust and adaptive and exhibits the better performance than other methods involved in the paper.

  17. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min

    1995-01-01

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease

  18. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease.

  19. Characterization of liver metastases: the efficacy of biphasic magnetic resonance imaging with ferucarbotran-enhancement

    International Nuclear Information System (INIS)

    Hong, H.S.; Byun, J.H.; Won, H.J.; Kim, K.W.; Lee, S.S.; Lee, M.G.; Yun, S.C.

    2010-01-01

    Aim: To retrospectively evaluate the efficacy of biphasic magnetic resonance imaging (MRI) of the liver with ferucarbotran-enhancement for the characterization of hepatic metastases. Materials and methods: Thirty-six patients underwent MRI of the liver with separate acquisition of double-contrast enhancement consisting of gadolinium and ferucarbotran. A total of 106 focal hepatic lesions (51 metastases, 31 cysts, 23 haemangiomas, and one eosinophilic abscess) were included. Two sets of MRI were analysed: (1) ferucarbotran set: ferucarbotran-enhanced T1-weighted (T1W) dynamic imaging combined with ferucarbotran-enhanced T2*-weighted (T2*W) delayed imaging and (2) double set: gadolinium-enhanced T1W dynamic imaging combined with ferucarbotran-enhanced T2*W delayed imaging. The diagnostic accuracy of the two sets was evaluated using alternative free-response receiver operating characteristic curve analysis. Sensitivity and specificity were compared using the McNemar test. The enhancement pattern of focal hepatic lesions was analysed on gadolinium and ferucarbotran-enhanced T1W dynamic imaging. Results: There was no significant difference in the accuracy of characterizing hepatic metastases between the two sets. Sensitivity and specificity were not significantly different between the sets (p > 0.05). Peripheral rim enhancement was exhibited in 57% of metastatic lesions on ferucarbotran-enhanced T1W dynamic imaging. The majority (96%) of hepatic haemangiomas demonstrated typical peripheral nodular enhancement with progression on ferucarbotran-enhanced T1W dynamic imaging and were easily differentiated from metastases. Conclusion: Biphasic MRI of the liver with ferucarbotran-enhancement alone provided comparable diagnostic efficacy to double-contrast MRI for the characterization of hepatic metastases.

  20. Diffraction enhanced kinetic depth X-ray imaging

    Science.gov (United States)

    Dicken, A.

    An increasing number of fields would benefit from a single analytical probe that can characterise bulk objects that vary in morphology and/or material composition. These fields include security screening, medicine and material science. In this study the X-ray region is shown to be an effective probe for the characterisation of materials. The most prominent analytical techniques that utilise X-radiation are reviewed. The study then focuses on methods of amalgamating the three dimensional power of kinetic depth X-ray (KDFX) imaging with the materials discrimination of angular dispersive X-ray diffraction (ADXRD), thus providing KDEX with a much needed material specific counterpart. A knowledge of the sample position is essential for the correct interpretation of diffraction signatures. Two different sensor geometries (i.e. circumferential and linear) that are able to collect end interpret multiple unknown material diffraction patterns and attribute them to their respective loci within an inspection volume are investigated. The circumferential and linear detector geometries are hypothesised, simulated and then tested in an experimental setting with the later demonstrating a greater ability at discerning between mixed diffraction patterns produced by differing materials. Factors known to confound the linear diffraction method such as sample thickness and radiation energy have been explored and quantified with a possible means of mitigation being identified (i.e. via increasing the sample to detector distance). A series of diffraction patterns (following the linear diffraction approach) were obtained from a single phantom object that was simultaneously interrogated via KDEX imaging. Areas containing diffraction signatures matched from a threat library have been highlighted in the KDEX imagery via colour encoding and match index is inferred by intensity. This union is the first example of its kind and is called diffraction enhanced KDEX imagery. Finally an additional

  1. The 2017 EULAR standardised procedures for ultrasound imaging in rheumatology

    DEFF Research Database (Denmark)

    Möller, Ingrid; Janta, Iustina; Backhaus, Marina

    2017-01-01

    of MSUS evaluable structures; (2) a Delphi survey among rheumatologist and radiologist experts in MSUS to select MS and non-MS anatomic structures evaluable by US that are relevant to rheumatology, to select abnormalities evaluable by US and to prioritise these pathologies for rheumatology and (3...

  2. Contrast-enhanced MR imaging monitoring of acute tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Ranney, D.F.; Cohen, J.M.; Antich, P.P.; Endman, W.A.; Kulkarni, P.; Weinreb, J.C.; Giovanella, B.

    1987-01-01

    Treatment responses of human malignant melanomas were monitored at millimeter resolution in athymic mice by injecting a new polymeric contrast agent, Gd-DTPA-dextran (0.1 mmol Gd/kg, intravenously). Proton MR imaging (0.35 T, spin-echo, repetition time = 0.5 second, echo time = 50 msec) was performed 30 hours after administering diphtheria toxin. Pre-contrast medium images revealed only homogeneous intermediate-intensity tumor masses. Post-contrast medium images of untreated (viable) tumors demonstrated 32% enhancement throughout the entire mass. Post-contrast medium images of toxin-treated tumors revealed marked enhancement (65%) of the histologically viable outer rims, lesser enhancement (38%) of heavily damaged subregions, and no enhancement of dead tumor. These acute, contrast medium-enhanced MR images accurately identified tumor subregions that survived for longer than one week

  3. Study of quality perception in medical images based on comparison of contrast enhancement techniques in mammographic images

    Science.gov (United States)

    Matheus, B.; Verçosa, L. B.; Barufaldi, B.; Schiabel, H.

    2014-03-01

    With the absolute prevalence of digital images in mammography several new tools became available for radiologist; such as CAD schemes, digital zoom and contrast alteration. This work focuses in contrast variation and how the radiologist reacts to these changes when asked to evaluated image quality. Three contrast enhancing techniques were used in this study: conventional equalization, CCB Correction [1] - a digitization correction - and value subtraction. A set of 100 images was used in tests from some available online mammographic databases. The tests consisted of the presentation of all four versions of an image (original plus the three contrast enhanced images) to the specialist, requested to rank each one from the best up to worst quality for diagnosis. Analysis of results has demonstrated that CCB Correction [1] produced better images in almost all cases. Equalization, which mathematically produces a better contrast, was considered the worst for mammography image quality enhancement in the majority of cases (69.7%). The value subtraction procedure produced images considered better than the original in 84% of cases. Tests indicate that, for the radiologist's perception, it seems more important to guaranty full visualization of nuances than a high contrast image. Another result observed is that the "ideal" scanner curve does not yield the best result for a mammographic image. The important contrast range is the middle of the histogram, where nodules and masses need to be seen and clearly distinguished.

  4. New LSB-based colour image steganography method to enhance ...

    Indian Academy of Sciences (India)

    Mustafa Cem kasapbaşi

    2018-04-27

    Apr 27, 2018 ... evaluate the proposed method, comparative performance tests are carried out against different spatial image ... image steganography applications based on LSB are ..... worst case scenario could occur when having highest.

  5. PENGGUNAAN WAVELET IMAGE ENHANCEMENT DAN TEKSTUR ENERGI CITRA UNTUK MENDETEKSI MASSA MENCURIGAKAN PADA MAMOGRAM

    Directory of Open Access Journals (Sweden)

    Heru Wahyu Herwanto

    2012-09-01

    Full Text Available Abstract: The Use of Wavelet Image Enhancement and Image Energy Texture for Detecting Suspected Mass in Mammogram. Breast cancer is one of the most dangerous cancer for female. The risk of the cancer can be lessened by early detection using mammography. This research sets out to detect and sign the edge of suspected mass in mammogram. The method used is an image enhancement and segmentation. The process of image enhancement uses the method of adaptive wavelet enhancement, meanwhile the segmentation uses the calculation of image energy texture with laws filter, smoothing, tressholding, morphology, and boudary extraction. The final result of this method will be compared with those of same method with corrected images abd adaptive histogram equalization. The result of the research shows that there is an improvement of enthropy, deviation standard, and contrast values. The overall execution program takes 1.82869 seconds longer than the adaptive histogram equalization.

  6. Recommendations for using standardised phenotypes in genetic association studies

    Directory of Open Access Journals (Sweden)

    Naylor Melissa G

    2009-07-01

    Full Text Available Abstract Genetic association studies of complex traits often rely on standardised quantitative phenotypes, such as percentage of predicted forced expiratory volume and body mass index to measure an underlying trait of interest (eg lung function, obesity. These phenotypes are appealing because they provide an easy mechanism for comparing subjects, although such standardisations may not be the best way to control for confounders and other covariates. We recommend adjusting raw or standardised phenotypes within the study population via regression. We illustrate through simulation that optimal power in both population- and family-based association tests is attained by using the residuals from within-study adjustment as the complex trait phenotype. An application of family-based association analysis of forced expiratory volume in one second, and obesity in the Childhood Asthma Management Program data, illustrates that power is maintained or increased when adjusted phenotype residuals are used instead of typical standardised quantitative phenotypes.

  7. High Frequency Sonar Elastic Image Enhancements: Ray Theory

    National Research Council Canada - National Science Library

    Marston, Philip

    2001-01-01

    .... All of the enhancements considered are associated with the target's mechanical response. An enhancement is discovered and analyzed for plastic and rubber cylinders usually considered to have weak backscattering...

  8. Enhancement of SAR images using fuzzy shrinkage technique

    Indian Academy of Sciences (India)

    This paper presents speckle noise reduction in SAR images using a combination of curvelet and fuzzy logic technique to restore speckle-affected images. This method overcomes the limitation of discontinuity in hard threshold and permanent deviation in soft threshold. First, it decomposes noise image into different ...

  9. Red blood cell image enhancement techniques for cells with ...

    African Journals Online (AJOL)

    quality or challenging conditions of the images such as poor illumination of blood smear and most importantly overlapping RBC. The algorithm comprises of two RBC segmentation that can be selected based on the image quality, circle mask technique and grayscale blood smear image processing. Detail explanations ...

  10. Variability induced by the MR imager in dynamic contrast-enhanced imaging of the prostate.

    Science.gov (United States)

    Brunelle, S; Zemmour, C; Bratan, F; Mège-Lechevallier, F; Ruffion, A; Colombel, M; Crouzet, S; Sarran, A; Rouvière, O

    2018-04-01

    To evaluate the variability induced by the imager in discriminating high-grade (Gleason≥7) prostate cancers (HGC) using dynamic contrast-enhanced MRI. We retrospectively selected 3T MRIs with temporal resolution<10 seconds and comprising T1 mapping from a prospective radiologic-pathologic database of patients treated by prostatectomy. Ktrans, Kep, Ve and Vp were calculated for each lesion seen on MRI using the Weinmann arterial input function (AIF) and three patient-specific AIFs measured in the right and left iliac arteries in pixels in the center of the lumen (psAIF-ST) or manually selected by two independent readers (psAIF-R1 and psAIF-R2). A total of 43 patients (mean age, 63.6±4.9 [SD]; range: 48-72 years) with 100 lesions on MRI (55 HGC) were selected. MRIs were performed on imager A (22 patients, 49 lesions) or B (21 patients, 51 lesions) from two different manufacturers. Using the Weinmann AIF, Kep (P=0.005), Ve (P=0.04) and Vp (P=0.01) significantly discriminated HCG. After adjusting on tissue classes, the imager significantly influenced the values of Kep (P=0.049) and Ve (P=0.007). Using patient-specific AIFs, Vp with psAIF-ST (P=0.008) and psAIF-R2 (P=0.04), and Kep with psAIF-R1 (P=0.03) significantly discriminated HGC. After adjusting on tissue classes, types of patient-specific AIF and side of measurement, the imager significantly influenced the values of Ktrans (P=0.0002), Ve (P=0.0072) and Vp (P=0.0003). For all AIFs, the diagnostic value of pharmacokinetic parameters remained unchanged after adjustment on the imager, with stable odds ratios. The imager induced variability in the absolute values of pharmacokinetic parameters but did not change their diagnostic performance. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. Usefulness of fat-suppressed Gd-enhanced MR imaging of tongue cancer

    International Nuclear Information System (INIS)

    Murakami, Shumei; Fuchihata, Hajime; Yoon, Sukja; Furukawa, Souhei; Kawai, Tadahiko; Kishino, Mitsunobu

    1999-01-01

    To evaluate the usefulness of the fat suppression technique for magnetic resonance imaging of oral tongue cancer. One hundred and fourteen patients underwent both magnetic resonance imaging (MRI) and computed tomography (CT). All patients were clinically diagnosed as having oral tongue cancer shown to be squamous cell carcinoma histopathologically. We used two types of CT and six types of MRI scanning: plain CT, contrast enhanced CT, conventional T1w, conventional PDw, conventional T2w, fat-suppressed (FATS) T1w, Gd-enhanced conventional T1w, and Gd-enhanced FATS T1w images. The focus of our study was Gd-enhanced FATS T1w imaging. Tumor detection rates were as follows: Gd-enhanced FATS T1w MRI, 86.8%; conventional T2w MRI, 71.9%; conventional PDw MRI, 65.8%; Gd-enhanced conventional T1w MRI, 47.4%; contrast enhanced CT, 36.8%; T1w MRI, 20.2%; CT, 10.5%. There were 59 cases in which tumors were detected by Gd-enhanced FATS T1w MRI but not detected by contrast enhanced CT. Gd-enhanced FATS T1w MRI was the best for the tumor detection and Gd-enhanced conventional T1w MRI was not useful in the diagnosis of the tongue cancer. CT imaging must not be the first choice for tumor detection in tongue cancer patients. (author)

  12. Image Enhancement via Subimage Histogram Equalization Based on Mean and Variance

    Directory of Open Access Journals (Sweden)

    Liyun Zhuang

    2017-01-01

    Full Text Available This paper puts forward a novel image enhancement method via Mean and Variance based Subimage Histogram Equalization (MVSIHE, which effectively increases the contrast of the input image with brightness and details well preserved compared with some other methods based on histogram equalization (HE. Firstly, the histogram of input image is divided into four segments based on the mean and variance of luminance component, and the histogram bins of each segment are modified and equalized, respectively. Secondly, the result is obtained via the concatenation of the processed subhistograms. Lastly, the normalization method is deployed on intensity levels, and the integration of the processed image with the input image is performed. 100 benchmark images from a public image database named CVG-UGR-Database are used for comparison with other state-of-the-art methods. The experiment results show that the algorithm can not only enhance image information effectively but also well preserve brightness and details of the original image.

  13. Image Enhancement via Subimage Histogram Equalization Based on Mean and Variance

    Science.gov (United States)

    2017-01-01

    This paper puts forward a novel image enhancement method via Mean and Variance based Subimage Histogram Equalization (MVSIHE), which effectively increases the contrast of the input image with brightness and details well preserved compared with some other methods based on histogram equalization (HE). Firstly, the histogram of input image is divided into four segments based on the mean and variance of luminance component, and the histogram bins of each segment are modified and equalized, respectively. Secondly, the result is obtained via the concatenation of the processed subhistograms. Lastly, the normalization method is deployed on intensity levels, and the integration of the processed image with the input image is performed. 100 benchmark images from a public image database named CVG-UGR-Database are used for comparison with other state-of-the-art methods. The experiment results show that the algorithm can not only enhance image information effectively but also well preserve brightness and details of the original image. PMID:29403529

  14. Image Enhancement via Subimage Histogram Equalization Based on Mean and Variance.

    Science.gov (United States)

    Zhuang, Liyun; Guan, Yepeng

    2017-01-01

    This paper puts forward a novel image enhancement method via Mean and Variance based Subimage Histogram Equalization (MVSIHE), which effectively increases the contrast of the input image with brightness and details well preserved compared with some other methods based on histogram equalization (HE). Firstly, the histogram of input image is divided into four segments based on the mean and variance of luminance component, and the histogram bins of each segment are modified and equalized, respectively. Secondly, the result is obtained via the concatenation of the processed subhistograms. Lastly, the normalization method is deployed on intensity levels, and the integration of the processed image with the input image is performed. 100 benchmark images from a public image database named CVG-UGR-Database are used for comparison with other state-of-the-art methods. The experiment results show that the algorithm can not only enhance image information effectively but also well preserve brightness and details of the original image.

  15. Estimating the 'consumer surplus' for branded versus standardised tobacco packaging.

    Science.gov (United States)

    Gendall, Philip; Eckert, Christine; Hoek, Janet; Farley, Tessa; Louviere, Jordan; Wilson, Nick; Edwards, Richard

    2016-11-01

    Tobacco companies question whether standardised (or 'plain') packaging will change smokers' behaviour. We addressed this question by estimating how standardised packaging compared to a proven tobacco control intervention, price increases through excise taxes, thus providing a quantitative measure of standardised packaging's likely effect. We conducted an online study of 311 New Zealand smokers aged 18 years and above that comprised a willingness-to-pay task comparing a branded and a standardised pack at four different price levels, and a choice experiment. The latter used an alternative-specific design, where the alternatives were a branded pack or a standardised pack, with warning theme and price varied for each pack. Respondents had higher purchase likelihoods for the branded pack (with a 30% warning) than the standardised pack (with a 75% warning) at each price level tested, and, on average, were willing to pay approximately 5% more for a branded pack. The choice experiment produced a very similar estimate of 'consumer surplus' for a branded pack. However, the size of the 'consumer surplus' varied between warning themes and by respondents' demographic characteristics. These two experiments suggest standardised packaging and larger warning labels could have a similar overall effect on adult New Zealand smokers as a 5% tobacco price increase. The findings provide further evidence for the efficacy of standardised packaging, which focuses primarily on reducing youth initiation, and suggest this measure will also bring notable benefits to adult smokers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Standardisation roadmap for electromobility; Normungs-Fahrplan fuer die Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Heusinger, Stefan [DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE, Frankfurt/Main (Germany). Bereich Standardisierung

    2011-03-15

    All internal combustion engines - even the most efficient ones - consume fossil fuels which are getting increasingly scarce. The future of power supply, also in the mobile sector, is in renewables and electromobility. In Germany, the NPE (National Platform for Electromobility) was founded in order to achieve standardisation in this field as early as possible. A standardisation roadmap was established which is to facilitate implementation of electromobility during the next few years.

  17. Scottish young people's perceptions of standardised packs - a qualitative study

    Directory of Open Access Journals (Sweden)

    Andy Macgregor

    2018-03-01

    Full Text Available Background Standardised cigarette packs were introduced into the UK in May 2016. Retailers could sell old stock until May 2017 after which only the sale of cigarettes and tobacco in standardised packs was allowed. As in Australia, pack shape, colour, opening mechanism and font are regulated, together with the size and position of health warnings and number of cigarettes in a pack. This paper explores Scottish young people's awareness of and views about standardised packs in Spring 2017. Methods The DISPLAY study is a five year study established to evaluate the national tobacco point-of sale (POS promotions ban in four communities in Scotland. This paper is based on the qualitative component, annual focus groups carried out with Secondary 2 (13 year olds and Secondary 4 (15 year olds students in four secondary schools. 16 groups (82 students convened in February - March 2017 explored students' perceptions of standardised packaging. Results There was a high level of awareness of standardised packs prior to their full implementation. Smokers had bought them, and they and other participants had seen them in possession of friends and family members, and in litter. Participants' views of the new packaging were generally negative, described as unappealing and depressing, particularly the pictorial health warnings. Packs were compared unfavourably with previous non-standardised versions. However, there was no consensus on their likely impact. Some participants argued that their impact would be widespread, while others thought that any impact would be confined to young non/occasional smokers and that established smokers would be unaffected. Conclusions In early 2017 young people in Scotland had high awareness and knowledge of standardised tobacco packs before their full implementation. Despite differing views about their likely impact on youth smoking, participants irrespective of smoking status overwhelmingly regarded them as unattractive and less

  18. Effects of image enhancement on reliability of landmark identification in digital cephalometry

    Directory of Open Access Journals (Sweden)

    M Oshagh

    2013-01-01

    Full Text Available Introduction: Although digital cephalometric radiography is gaining popularity in orthodontic practice, the most important source of error in its tracing is uncertainty in landmark identification. Therefore, efforts to improve accuracy in landmark identification were directed primarily toward the improvement in image quality. One of the more useful techniques of this process involves digital image enhancement which can increase overall visual quality of image, but this does not necessarily mean a better identification of landmarks. The purpose of this study was to evaluate the effectiveness of digital image enhancements on reliability of landmark identification. Materials and Methods: Fifteen common landmarks including 10 skeletal and 5 soft tissues were selected on the cephalograms of 20 randomly selected patients, prepared in Natural Head Position (NHP. Two observers (orthodontists identified landmarks on the 20 original photostimulable phosphor (PSP digital cephalogram images and 20 enhanced digital images twice with an intervening time interval of at least 4 weeks. The x and y coordinates were further analyzed to evaluate the pattern of recording differences in horizontal and vertical directions. Reliability of landmarks identification was analyzed by paired t test. Results: There was a significant difference between original and enhanced digital images in terms of reliability of points Ar and N in vertical and horizontal dimensions, and enhanced images were significantly more reliable than original images. Identification of A point, Pogonion and Pronasal points, in vertical dimension of enhanced images was significantly more reliable than original ones. Reliability of Menton point identification in horizontal dimension was significantly more in enhanced images than original ones. Conclusion: Direct digital image enhancement by altering brightness and contrast can increase reliability of some landmark identification and this may lead to more

  19. A novel image-domain-based cone-beam computed tomography enhancement algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiang; Li Tianfang; Yang Yong; Heron, Dwight E; Huq, M Saiful, E-mail: lix@upmc.edu [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, PA 15232 (United States)

    2011-05-07

    Kilo-voltage (kV) cone-beam computed tomography (CBCT) plays an important role in image-guided radiotherapy. However, due to a large cone-beam angle, scatter effects significantly degrade the CBCT image quality and limit its clinical application. The goal of this study is to develop an image enhancement algorithm to reduce the low-frequency CBCT image artifacts, which are also called the bias field. The proposed algorithm is based on the hypothesis that image intensities of different types of materials in CBCT images are approximately globally uniform (in other words, a piecewise property). A maximum a posteriori probability framework was developed to estimate the bias field contribution from a given CBCT image. The performance of the proposed CBCT image enhancement method was tested using phantoms and clinical CBCT images. Compared to the original CBCT images, the corrected images using the proposed method achieved a more uniform intensity distribution within each tissue type and significantly reduced cupping and shading artifacts. In a head and a pelvic case, the proposed method reduced the Hounsfield unit (HU) errors within the region of interest from 300 HU to less than 60 HU. In a chest case, the HU errors were reduced from 460 HU to less than 110 HU. The proposed CBCT image enhancement algorithm demonstrated a promising result by the reduction of the scatter-induced low-frequency image artifacts commonly encountered in kV CBCT imaging.

  20. Multi-technology Integration Based on Low-contrast Microscopic Image Enhancement

    Directory of Open Access Journals (Sweden)

    Haoge Ma

    2014-01-01

    Full Text Available Microscopic image enhancement is an important issue of image processing technique, which is used to improve the visual quality of image. This paper describes a novel multi resolution image segmentation algorithm for low DOF images. The algorithm is designed to separate a sharply focused object of interest from other foreground or background objects. The algorithm is fully automatic in that all parameters are image in dependent. A multiscale-approach based on high frequency wavelet coefficients and their statistics is used to perform context dependent classification of individual blocks of the image. Compared with the state of the art algorithms, this new algorithm provides better accuracy at higher speed.

  1. Gadolinium-enhanced turbo FLASH MR imaging of renal perfusion and excretion

    International Nuclear Information System (INIS)

    Watanabe, A.; Teresi, L.M.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Smith, C.; Renner, J.; Rappaport, A.; Bradley, W.G. Jr.

    1990-01-01

    This paper describes a novel approach to MR imaging of renal perfusion and excretion using gadolinium-enhanced, T1-weighted TURBP, fast low-angle shot (FLASH) imaging. Five normal volunteers and four patients were studied on a 1.5-T imaging system. Time-intensity curves of the appearance of gadolinium in each kidney and the bladder were then generated. In normal volunteers, marked first-pass enhancement of renal cortex followed by renal pyramids and collecting systems could be demonstrated on the first-pass gadolinium images. Delayed images showed hyperintense gadolinium within the bladder

  2. Image enhancement circuit using nonlinear processing curve and constrained histogram range equalization

    NARCIS (Netherlands)

    Cvetkovic, S.D.; With, de P.H.N.; Panchanathan, S.; Vasudev, B.

    2004-01-01

    For real-time imaging in surveillance applications, image fidelity is of primary importance to ensure customer confidence. The obtained image fidelity is a result from amongst others dynamic range expansion and video signal enhancement. The dynamic range of the signal needs adaptation, because the

  3. The Multiscale Bowler-Hat Transform for Vessel Enhancement in 3D Biomedical Images

    OpenAIRE

    Sazak, Cigdem; Nelson, Carl J.; Obara, Boguslaw

    2018-01-01

    Enhancement and detection of 3D vessel-like structures has long been an open problem as most existing image processing methods fail in many aspects, including a lack of uniform enhancement between vessels of different radii and a lack of enhancement at the junctions. Here, we propose a method based on mathematical morphology to enhance 3D vessel-like structures in biomedical images. The proposed method, 3D bowler-hat transform, combines sphere and line structuring elements to enhance vessel-l...

  4. Detection of brain metastasis. Comparison of Turbo-FLAIR imaging, T2-weighted imaging and double-dose gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Okubo, Toshiyuki; Hayashi, Naoto; Shirouzu, Ichiro; Abe, Osamu; Ohtomo, Kuni; Sasaki, Yasuhito; Aoki, Shigeki; Wada, Akihiko

    1998-01-01

    The purpose of this study was to compare Turbo-FLAIR imaging, T 2 -weighted imaging, and double-dose gadolinium-enhanced MR imaging in the detection of brain metastasis. Using the three sequences, 20 consecutive patients with brain metastases were prospectively studied with a 1.5-Tesla system. Three independent, blinded readers assessed the images for the presence, size, number, and location of metastatic lesions. In the detection of large lesions (>0.5 cm), Turbo-FLAIR imaging (38/48, 79%) was not significantly different from gadolinium-enhanced imaging (42/48, 88%) (p=0.273). T 2 -weighted imaging (31/48, 65%), however, was inferior to gadolinium-enhanced imaging (p<0.05). There was no difference between Turbo-FLAIR imaging and gadolinium-enhanced imaging in the accuracy of detecting solitary brain metastasis (4/4, 100%). In conclusion, Turbo-FLAIR imaging is a useful, noninvasive screening modality for brain metastasis. Its use may lead to cost savings in the diagnosis of brain metastases and may impact positively the cost-effectiveness of treatment. (author)

  5. Contrast-enhanced fat- suppression MR imaging of avascular necrosis of femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Tae Kyoung; Shim, Jae Chan; Lee, Ghi Jai; Jeon, Jeong Dong; Bang, Sun Woo; Kim, Ho Kyun [College of Medicine, Inje University, Seoul (Korea, Republic of)

    2000-02-01

    To evaluate the findings and role of contrast-enhanced fat suppression MR imaging in avascular necrosis (AVN) of the femoral head. In 15 patients with AVN of the femoral head, MR T1-weighted and T2-weighted images and contrast-enhanced fat-suppression T1-weighted images were obtained, and the findings were reviewed. Early and advanced groups were classified on the basis of clinical findings and imaging, and the enhancement pattern was classified as either type I, rim enhancement; type II, surrounding diffuse enhancement; type III, intralesional enhancement; or type IV, II + III. Twenty-four cases of AVN of the femoral head were detected; in nine patients, lesions were bilateral. Eight cases occurred in the early group and 16 in the advanced. All eight in the early group showed the 'double line sign' on T2-weighted images, with a type-I enhancement pattern. In the advanced group, type II (8/16) and type IV (8/16) enhancement patterns were seen. Among the cases showing the type-IV pattern, the intralesional enhancing area showed low signal intensity on T1-weighted images and isosignal intensity on T2-weighted in one case, and low signal intensity on T2-weighted in one case, and low signal intensity on T1-weighted images and high signal intensity on T2-weighted in the other cases. There was no difference in the extent of the disease before and after enhancement. Contrast-enhanced fat-suppression MR images may be helpful in evaluating the extent of AVN of the femoral head and predicting the histopathologic findings of the disease. (author)

  6. Contrast-enhanced fat- suppression MR imaging of avascular necrosis of femoral head

    International Nuclear Information System (INIS)

    Oh, Tae Kyoung; Shim, Jae Chan; Lee, Ghi Jai; Jeon, Jeong Dong; Bang, Sun Woo; Kim, Ho Kyun

    2000-01-01

    To evaluate the findings and role of contrast-enhanced fat suppression MR imaging in avascular necrosis (AVN) of the femoral head. In 15 patients with AVN of the femoral head, MR T1-weighted and T2-weighted images and contrast-enhanced fat-suppression T1-weighted images were obtained, and the findings were reviewed. Early and advanced groups were classified on the basis of clinical findings and imaging, and the enhancement pattern was classified as either type I, rim enhancement; type II, surrounding diffuse enhancement; type III, intralesional enhancement; or type IV, II + III. Twenty-four cases of AVN of the femoral head were detected; in nine patients, lesions were bilateral. Eight cases occurred in the early group and 16 in the advanced. All eight in the early group showed the 'double line sign' on T2-weighted images, with a type-I enhancement pattern. In the advanced group, type II (8/16) and type IV (8/16) enhancement patterns were seen. Among the cases showing the type-IV pattern, the intralesional enhancing area showed low signal intensity on T1-weighted images and isosignal intensity on T2-weighted in one case, and low signal intensity on T2-weighted in one case, and low signal intensity on T1-weighted images and high signal intensity on T2-weighted in the other cases. There was no difference in the extent of the disease before and after enhancement. Contrast-enhanced fat-suppression MR images may be helpful in evaluating the extent of AVN of the femoral head and predicting the histopathologic findings of the disease. (author)

  7. Pulse sequences for contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Graves, Martin J.

    2007-01-01

    The theory and application of magnetic resonance imaging (MRI) pulse sequences following the administration of an exogenous contrast agent are discussed. Pulse sequences are categorised according to the contrast agent mechanism: changes in proton density, relaxivity, magnetic susceptibility and resonant frequency shift. Applications in morphological imaging, magnetic resonance angiography, dynamic imaging and cell labelling are described. The importance of optimising the pulse sequence for each application is emphasised

  8. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    Science.gov (United States)

    Gan, Hong-Seng; Swee, Tan Tian; Abdul Karim, Ahmad Helmy; Sayuti, Khairil Amir; Abdul Kadir, Mohammed Rafiq; Tham, Weng-Kit; Wong, Liang-Xuan; Chaudhary, Kashif T.; Yupapin, Preecha P.

    2014-01-01

    Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of “adequate contrast enhancement” to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image's maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher's Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection. PMID:24977191

  9. Feature and Contrast Enhancement of Mammographic Image Based on Multiscale Analysis and Morphology

    Directory of Open Access Journals (Sweden)

    Shibin Wu

    2013-01-01

    Full Text Available A new algorithm for feature and contrast enhancement of mammographic images is proposed in this paper. The approach bases on multiscale transform and mathematical morphology. First of all, the Laplacian Gaussian pyramid operator is applied to transform the mammography into different scale subband images. In addition, the detail or high frequency subimages are equalized by contrast limited adaptive histogram equalization (CLAHE and low-pass subimages are processed by mathematical morphology. Finally, the enhanced image of feature and contrast is reconstructed from the Laplacian Gaussian pyramid coefficients modified at one or more levels by contrast limited adaptive histogram equalization and mathematical morphology, respectively. The enhanced image is processed by global nonlinear operator. The experimental results show that the presented algorithm is effective for feature and contrast enhancement of mammogram. The performance evaluation of the proposed algorithm is measured by contrast evaluation criterion for image, signal-noise-ratio (SNR, and contrast improvement index (CII.

  10. A review on brightness preserving contrast enhancement methods for digital image

    Science.gov (United States)

    Rahman, Md Arifur; Liu, Shilong; Li, Ruowei; Wu, Hongkun; Liu, San Chi; Jahan, Mahmuda Rawnak; Kwok, Ngaiming

    2018-04-01

    Image enhancement is an imperative step for many vision based applications. For image contrast enhancement, popular methods adopt the principle of spreading the captured intensities throughout the allowed dynamic range according to predefined distributions. However, these algorithms take little or no consideration into account of maintaining the mean brightness of the original scene, which is of paramount importance to carry the true scene illumination characteristics to the viewer. Though there have been significant amount of reviews on contrast enhancement methods published, updated review on overall brightness preserving image enhancement methods is still scarce. In this paper, a detailed survey is performed on those particular methods that specifically aims to maintain the overall scene illumination characteristics while enhancing the digital image.

  11. Information extracting and processing with diffraction enhanced imaging of X-ray

    International Nuclear Information System (INIS)

    Chen Bo; Chinese Academy of Science, Beijing; Chen Chunchong; Jiang Fan; Chen Jie; Ming Hai; Shu Hang; Zhu Peiping; Wang Junyue; Yuan Qingxi; Wu Ziyu

    2006-01-01

    X-ray imaging at high energies has been used for many years in many fields. Conventional X-ray imaging is based on the different absorption within a sample. It is difficult to distinguish different tissues of a biological sample because of their small difference in absorption. The authors use the diffraction enhanced imaging (DEI) method. The authors took images of absorption, extinction, scattering and refractivity. In the end, the authors presented pictures of high resolution with all these information combined. (authors)

  12. Image combination enhancement method for X-ray compton back-scattering security inspection body scanner

    International Nuclear Information System (INIS)

    Wang Huaiying; Zhang Yujin; Yang Lirui; Li Dong

    2011-01-01

    As for X-ray Compton Back-Scattering (CBS) body scanner, image clearness is very important for the performance of detecting the contraband hidden on the body. A new image combination enhancement method is provided based on characteristics of CBS body images and points of human vision. After processed by this method, the CBS image will be obviously improved with clear levels, distinct outline and uniform background. (authors)

  13. Changes of renal blood flow after ESWL: assessment by ASL MR imaging, contrast enhanced MR imaging, and renal resistive index.

    Science.gov (United States)

    Abd Ellah, Mohamed; Kremser, Christian; Pallwein, Leo; Aigner, Friedrich; Schocke, Michael; Peschel, Reinhard; Pedross, Florian; Pinggera, Germar-Michael; Wolf, Christian; Alsharkawy, Mostafa A M; Jaschke, Werner; Frauscher, Ferdinand

    2010-10-01

    The annual incidence of stone formation is increased in the industrialised world. Extracorporeal shockwave lithotripsy is a non-invasive effective treatment of upper urinary tract stones. This study is aimed to evaluate changes of renal blood flow in patients undergoing extracorporeal shock wave lithotripsy (ESWL) by arterial spin labeling (ASL) MR imaging, contrast enhanced dynamic MR imaging, and renal resistive index (RI). Thirteen patients with nephrolithiasis were examined using MR imaging and Doppler ultrasound 12h before and 12h after ESWL. ASL sequence was done for both kidneys and followed by contrast enhanced MR imaging. In addition RI Doppler ultrasound measurements were performed. A significant increase in RI (pESWL causes changes in RI and ASL MR imaging, which seem to reflect changes in renal blood flow. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  14. Swarm Intelligence for Optimizing Hybridized Smoothing Filter in Image Edge Enhancement

    Science.gov (United States)

    Rao, B. Tirumala; Dehuri, S.; Dileep, M.; Vindhya, A.

    In this modern era, image transmission and processing plays a major role. It would be impossible to retrieve information from satellite and medical images without the help of image processing techniques. Edge enhancement is an image processing step that enhances the edge contrast of an image or video in an attempt to improve its acutance. Edges are the representations of the discontinuities of image intensity functions. For processing these discontinuities in an image, a good edge enhancement technique is essential. The proposed work uses a new idea for edge enhancement using hybridized smoothening filters and we introduce a promising technique of obtaining best hybrid filter using swarm algorithms (Artificial Bee Colony (ABC), Particle Swarm Optimization (PSO) and Ant Colony Optimization (ACO)) to search for an optimal sequence of filters from among a set of rather simple, representative image processing filters. This paper deals with the analysis of the swarm intelligence techniques through the combination of hybrid filters generated by these algorithms for image edge enhancement.

  15. Learning a No-Reference Quality Assessment Model of Enhanced Images With Big Data.

    Science.gov (United States)

    Gu, Ke; Tao, Dacheng; Qiao, Jun-Fei; Lin, Weisi

    2018-04-01

    In this paper, we investigate into the problem of image quality assessment (IQA) and enhancement via machine learning. This issue has long attracted a wide range of attention in computational intelligence and image processing communities, since, for many practical applications, e.g., object detection and recognition, raw images are usually needed to be appropriately enhanced to raise the visual quality (e.g., visibility and contrast). In fact, proper enhancement can noticeably improve the quality of input images, even better than originally captured images, which are generally thought to be of the best quality. In this paper, we present two most important contributions. The first contribution is to develop a new no-reference (NR) IQA model. Given an image, our quality measure first extracts 17 features through analysis of contrast, sharpness, brightness and more, and then yields a measure of visual quality using a regression module, which is learned with big-data training samples that are much bigger than the size of relevant image data sets. The results of experiments on nine data sets validate the superiority and efficiency of our blind metric compared with typical state-of-the-art full-reference, reduced-reference and NA IQA methods. The second contribution is that a robust image enhancement framework is established based on quality optimization. For an input image, by the guidance of the proposed NR-IQA measure, we conduct histogram modification to successively rectify image brightness and contrast to a proper level. Thorough tests demonstrate that our framework can well enhance natural images, low-contrast images, low-light images, and dehazed images. The source code will be released at https://sites.google.com/site/guke198701/publications.

  16. MR imaging with Gd-DTPA enhancement in experimental acute injury of the spinal cord

    International Nuclear Information System (INIS)

    Hackney, D.B.; Asato, R.; Joseph, P.M.; McGrath, J.T.; Grossman, R.I.; Shetty, A.

    1986-01-01

    The authors performed MR imaging with Gd-DTPA enhancement in adult male Sprague-Dawley rats, with experimentally induced acute spinal cored injuries. After epidural compression of the spinal cored the pathologic changes of acute cord contusion were allowed to develop for 30 minutes to 4 hours. MR imaging was then performed at 1.4 T. Both short spin-echo (TR = 400 msec, TE = 15-20 msec) and long spin-echo (TR = 2,000 msec, TE = 100 msec) images were obtained. After the initial imaging, Gd-DTPA (0.1 mmol/kg) and Evans blue dye were administered intravenously and imaging was repeated. Enhancement of normal central gray matter was consistently observed. However, neither pathologic enhancement on MR images nor extravasation of Evans blue dye on histologic inspection were identified

  17. Enhancing security of DICOM images during storage and ...

    Indian Academy of Sciences (India)

    Brain tumour Image is in DICOM standard (Rosslyn 1996) in which the patient informa- tion including name, birth date, gender, history are included in object classes. This information is sensitive to the patient and important for radiologist diagnosis. Data security becomes an important issue when brain tumour images are ...

  18. Enhancement of SAR images using fuzzy shrinkage technique in ...

    Indian Academy of Sciences (India)

    Shivakumara Swamy Puranik Math

    2017-08-03

    Aug 3, 2017 ... not use threshold approach only by proper selection of shrinking parameter the speckle in SAR image is ... but cost estimation of hyper-parameters will be high. The ..... To find the effectiveness of the proposed image in a.

  19. Hypervascular hepatocellular carcinomas: detection with gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Hiromitsu; Kim, Tonsok; Hori, Masatoshi; Nakaya, Yasuhiro; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tatsumi, Mitsuaki; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan); Imai, Yasuharu [Ikeda Municipal Hospital, Department of Gastroenterology, Ikeda, Osaka (Japan); Nagano, Hiroaki [Osaka University Graduate School of Medicine, Department of Surgery, Suita, Osaka (Japan); Kumano, Seishi; Okada, Masahiro; Murakami, Takamichi [Kinki University School of Medicine, Department of Radiology, Osakasayama, Osaka (Japan); Takamura, Manabu [Ikeda Municipal Hospital, Department of Radiology, Ikeda, Osaka (Japan); Wakasa, Kenichi [Osaka City University Graduate School of Medicine, Department of Diagnostic Pathology, Osaka, Osaka (Japan)

    2012-04-15

    To retrospectively compare the accuracy of detection of hypervascular hepatocellular carcinoma (HCC) by multiphasic multidetector CT and by gadoxetate disodium-enhanced MR imaging. After ethical approval, we analysed a total of 73 hypervascular HCC lesions from 31 patients suspected of having HCC, who underwent both gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Five blinded observers independently reviewed CT images, as well as dynamic MR images alone and combined with hepatobiliary phase MR images. Diagnostic accuracy (Az values), sensitivities and positive predictive values were compared by using the Scheffe post hoc test. The mean Az value for dynamic and hepatobiliary phase MR combined (0.81) or dynamic MR images alone (0.78) was significantly higher than that for CT images (0.67, P < 0.001, 0.005, respectively). The mean sensitivity of the combined MR images (0.67) was significantly higher than that of dynamic MR alone (0.52, P < 0.05) or CT images (0.44, P < 0.05). The mean positive predictive values were 0.96, 0.95 and 0.94, for CT, dynamic MR alone and combined MR images, respectively. Compared with multiphasic multidetector CT, gadoxetate disodium-enhanced MR imaging combining dynamic and hepatobiliary phase images results in significantly improved sensitivity and diagnostic accuracy for detection of hypervascular HCC. (orig.)

  20. MR imaging signal enhancement of normal intracranial and extracranial structures

    International Nuclear Information System (INIS)

    Muraki, A.S.; Carvlin, M.J.; Francisco, J.; Rocklage, S.M.; Quay, S.

    1988-01-01

    The authors report their initial experience using a paramagnetic manganese chelate complex as a contrast agent for magnetic resonance (MR) imaging of the central nervous system. Five female cats weighing 2-4 kg were used, and anesthesia was induced and maintained with intravenous nembutal (15-25 mg/kg). This contrast agent, manganese (II) N, N'-bis(pyridoxal-5-phosphate) ethylenediamine-N,N'-diacetic acid, or Mn(DPDP)(Salutar), has previously shown efficacy for MR imaging of the hepatobiliary axis but has not been employed in neuroradiologic imaging. T1-weighted (repetition time, 400 msec, echo time, 15, 26 msec; 4-mm sections) spin-echo images were acquired before and after intravenous administration (100 μmol/kg) of the contrast agent. On post-contrast images, the pituitary gland, infundibulum and portohypophyseal system of the hypothalamus and choroid lexus demonstrated signal increase at t=0-30 minutes after injection

  1. Basivertebral plexus enhancement at MR imaging after Gd-DTPA administration

    International Nuclear Information System (INIS)

    Bronstein, A.D.; Cohen, W.A.; Maravilla, K.R.

    1989-01-01

    This paper presents a study to identify noncontrast versus post-Gd-DTPA MR images of the spine, we analyzed the basivertebral plexus. The authors postulate that there are consistent patterns of enhancement specific with Gd-DTPA. This is a retrospective examination of the normal appearance and enhancement patterns of the basivertebral plexus in 805 vertebrae of 30 patients who underwent pre- and post-Gd-DTPA T1-weighted sagittal MR imaging of the spine. All patients show enhancement of the basivertebral plexus in a significant number of vertebrae when pre-and postcontrast images are compared

  2. Troubleshooting arterial-phase MR images of gadoxetate disodium-enhanced liver

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Ji Mi; Kim, So Yeon; Lee, Seung Soo; Kim, Kyoung Won [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yeh, Benjamin M.; Wang, Z. Jane [Dept. of Radiologyand Biomedical Imaging, University of California San Francisco, San Francisco (United States); Wu, En Haw [Dept. of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou and Chang Gung University College of Medicine, Taoyuan (China); Zhao, Li Qin [Beijing Friendship Hospital, Capital Medical University, Beijing (China); Chang, Wei Chou [Tri-Service General Hospital and National Defense Medical Center, Taipei (China)

    2015-12-15

    Gadoxetate disodium is a widely used magnetic resonance (MR) contrast agent for liver MR imaging, and it provides both dynamic and hepatobiliary phase images. However, acquiring optimal arterial phase images at liver MR using gadoxetate disodium is more challenging than using conventional extracellular MR contrast agent because of the small volume administered, the gadolinium content of the agent, and the common occurrence of transient severe motion. In this article, we identify the challenges in obtaining high-quality arterial-phase images of gadoxetate disodium-enhanced liver MR imaging and present strategies for optimizing arterial-phase imaging based on the thorough review of recent research in this field.

  3. Troubleshooting arterial-phase MR images of gadoxetate disodium-enhanced liver

    International Nuclear Information System (INIS)

    Huh, Ji Mi; Kim, So Yeon; Lee, Seung Soo; Kim, Kyoung Won; Yeh, Benjamin M.; Wang, Z. Jane; Wu, En Haw; Zhao, Li Qin; Chang, Wei Chou

    2015-01-01

    Gadoxetate disodium is a widely used magnetic resonance (MR) contrast agent for liver MR imaging, and it provides both dynamic and hepatobiliary phase images. However, acquiring optimal arterial phase images at liver MR using gadoxetate disodium is more challenging than using conventional extracellular MR contrast agent because of the small volume administered, the gadolinium content of the agent, and the common occurrence of transient severe motion. In this article, we identify the challenges in obtaining high-quality arterial-phase images of gadoxetate disodium-enhanced liver MR imaging and present strategies for optimizing arterial-phase imaging based on the thorough review of recent research in this field

  4. Application of Super-Resolution Convolutional Neural Network for Enhancing Image Resolution in Chest CT.

    Science.gov (United States)

    Umehara, Kensuke; Ota, Junko; Ishida, Takayuki

    2017-10-18

    In this study, the super-resolution convolutional neural network (SRCNN) scheme, which is the emerging deep-learning-based super-resolution method for enhancing image resolution in chest CT images, was applied and evaluated using the post-processing approach. For evaluation, 89 chest CT cases were sampled from The Cancer Imaging Archive. The 89 CT cases were divided randomly into 45 training cases and 44 external test cases. The SRCNN was trained using the training dataset. With the trained SRCNN, a high-resolution image was reconstructed from a low-resolution image, which was down-sampled from an original test image. For quantitative evaluation, two image quality metrics were measured and compared to those of the conventional linear interpolation methods. The image restoration quality of the SRCNN scheme was significantly higher than that of the linear interpolation methods (p < 0.001 or p < 0.05). The high-resolution image reconstructed by the SRCNN scheme was highly restored and comparable to the original reference image, in particular, for a ×2 magnification. These results indicate that the SRCNN scheme significantly outperforms the linear interpolation methods for enhancing image resolution in chest CT images. The results also suggest that SRCNN may become a potential solution for generating high-resolution CT images from standard CT images.

  5. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    Directory of Open Access Journals (Sweden)

    Hong-Seng Gan

    2014-01-01

    Full Text Available Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of “adequate contrast enhancement” to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image’s maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher’s Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection.

  6. Recurrent medulloblastoma: Frequency of tumor enhancement on Gd-DTPA MR imaging

    International Nuclear Information System (INIS)

    Rollins, N.; Mendelsohn, D.; Mulne, A.; Barton, R.; Diehl, J.; Reyes, N.; Sklar, F.

    1990-01-01

    Thirty-two children with medulloblastoma were evaluated postoperatively with conventional and gadolinium-enhanced MR imaging. Eleven patients had abnormal cranial MR studies; nine of these had recurrent tumor. In six patients recurrent tumor enhanced with Gd, while in the other three patients recurrent tumor did not enhance. The remaining two patients had areas of abnormal Gd enhancement that were caused by radiation-induced breakdown of the blood-brain barrier rather than by recurrent tumor. This study shows that not all recurrent medulloblastoma enhances and that the absence of Gd enhancement does not necessarily indicate the absence of recurrent tumor

  7. Gadoxetic acid-enhanced magnetic resonance imaging characteristics of hepatocellular carcinoma occurring in liver transplants

    International Nuclear Information System (INIS)

    Kim, Mimi; Kang, Tae Wook; Jeong, Woo Kyoung; Kim, Young Kon; Kim, Seong Hyun; Kim, Jong Man; Sinn, Dong Hyun; Kim, Min-Ji; Jung, Sin-ho

    2017-01-01

    Characteristics of hepatocellular carcinoma (HCC) on magnetic resonance (MR) images were compared in patients who did or did not undergo liver transplantation (LT), and we evaluated the relationship of these findings with overall survival (OS) and time-to-tumour recurrence (TTR) after transplantation. The enhancement pattern of gadoxetic acid-enhanced MR images of 25 patients with recurrent HCCs (LT group) and 25 surgically confirmed HCC patients in the non-transplanted (control) group were compared. Typical enhancement was defined as 1) arterial enhancement and delayed wash-out and 2) absence of typical features of cholangiocarcinoma consisting of arterial rim enhancement and target appearance on hepatobiliary phase images. OS and TTR were analyzed in the LT group according to these patterns using the log-rank test. HCCs in the LT group significantly more often had an atypical enhancement pattern (16/25, 64.0%) than those in the control group (5/25, 20.0%; p = 0.004). However, OS and TTR did not differ significantly according to these enhancement patterns of recurrent HCC (p > 0.05). Although enhancement patterns of recurrent HCC in transplanted liver did not affect OS and TTR, these HCCs that arise after LT frequently revealed atypical enhancement on gadoxetic acid-enhanced MR imaging. (orig.)

  8. Gadoxetic acid-enhanced magnetic resonance imaging characteristics of hepatocellular carcinoma occurring in liver transplants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mimi [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Hanyang University of Hospital, Department of Radiology, Seoul (Korea, Republic of); Kang, Tae Wook; Jeong, Woo Kyoung; Kim, Young Kon; Kim, Seong Hyun [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Jong Man [Sungkyunkwan University School of Medicine, Department of Surgery, Samsung Medical Center, Seoul (Korea, Republic of); Sinn, Dong Hyun [Sungkyunkwan University School of Medicine, Division of hepatology, Department of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Min-Ji; Jung, Sin-ho [Samsung Medical Center, Biostatics and Clinical Epidemiology Center, Seoul (Korea, Republic of)

    2017-08-15

    Characteristics of hepatocellular carcinoma (HCC) on magnetic resonance (MR) images were compared in patients who did or did not undergo liver transplantation (LT), and we evaluated the relationship of these findings with overall survival (OS) and time-to-tumour recurrence (TTR) after transplantation. The enhancement pattern of gadoxetic acid-enhanced MR images of 25 patients with recurrent HCCs (LT group) and 25 surgically confirmed HCC patients in the non-transplanted (control) group were compared. Typical enhancement was defined as 1) arterial enhancement and delayed wash-out and 2) absence of typical features of cholangiocarcinoma consisting of arterial rim enhancement and target appearance on hepatobiliary phase images. OS and TTR were analyzed in the LT group according to these patterns using the log-rank test. HCCs in the LT group significantly more often had an atypical enhancement pattern (16/25, 64.0%) than those in the control group (5/25, 20.0%; p = 0.004). However, OS and TTR did not differ significantly according to these enhancement patterns of recurrent HCC (p > 0.05). Although enhancement patterns of recurrent HCC in transplanted liver did not affect OS and TTR, these HCCs that arise after LT frequently revealed atypical enhancement on gadoxetic acid-enhanced MR imaging. (orig.)

  9. Toward standardising gamma camera quality control procedures

    International Nuclear Information System (INIS)

    Alkhorayef, M.A.; Alnaaimi, M.A.; Alduaij, M.A.; Mohamed, M.O.; Ibahim, S.Y.; Alkandari, F.A.; Bradley, D.A.

    2015-01-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services. - Highlights: • Optimal parameters for quality control of the gamma camera are proposed. • For extrinsic and intrinsic uniformity a minimum of 15,000 counts is recommended. • For intrinsic flood uniformity the activity should not exceed 100 µCi (3.7 MBq). • For intrinsic uniformity the source to detector distance should be at least 60 cm. • The bar phantom measurement must be performed with at least 15 million counts.

  10. Imaging of cauda equina edema in lumbar canal stenosis by using gadolinium-enhanced MR imaging: experimental constriction injury.

    Science.gov (United States)

    Kobayashi, S; Uchida, K; Takeno, K; Baba, H; Suzuki, Y; Hayakawa, K; Yoshizawa, H

    2006-02-01

    It has been reported that disturbance of blood flow arising from circumferential compression of the cauda equina by surrounding tissue plays a major role in the appearance of neurogenic intermittent claudication (NIC) associated with lumbar spinal canal stenosis (LSCS). We created a model of LSCS to clarify the mechanism of enhancement within the cauda equina on gadolinium-enhanced MR images from patients with LSCS. In 20 dogs, a lumbar laminectomy was performed by applying circumferential constriction to the cauda equina by using a silicon tube, to produce 30% stenosis of the circumferential diameter of the dural tube. After 1 and 3 weeks, gadolinium and Evans blue albumin were injected intravenously at the same time. The sections were used to investigate the status of the blood-nerve barrier function under a fluorescence microscope and we compared gadolinium-enhanced MR images with Evans blue albumin distribution in the nerve. The other sections were used for light and transmission electron microscopic study. In this model, histologic examination showed congestion and dilation in many of the intraradicular veins, as well as inflammatory cell infiltration. The intraradicular edema caused by venous congestion and Wallerian degeneration can also occur at sites that are not subject to mechanical compression. Enhanced MR imaging showed enhancement of the cauda equina at the stenosed region, demonstrating the presence of edema. Gadolinium-enhanced MR imaging may be a useful tool for the diagnosis of microcirculatory disorders of the cauda equina associated with LSCS.

  11. Dynamic contrast-enhanced MR imaging of endometrial cancer. Optimizing the imaging delay for tumour-myometrium contrast

    International Nuclear Information System (INIS)

    Park, Sung Bin; Moon, Min Hoan; Sung, Chang Kyu; Oh, Sohee; Lee, Young Ho

    2014-01-01

    To investigate the optimal imaging delay time of dynamic contrast-enhanced magnetic resonance (MR) imaging in women with endometrial cancer. This prospective single-institution study was approved by the institutional review board, and informed consent was obtained from the participants. Thirty-five women (mean age, 54 years; age range, 29-66 years) underwent dynamic contrast-enhanced MR imaging with a temporal resolution of 25-40 seconds. The signal intensity difference ratios between the myometrium and endometrial cancer were analyzed to investigate the optimal imaging delay time using single change-point analysis. The optimal imaging delay time for appropriate tumour-myometrium contrast ranged from 31.7 to 268.1 seconds. The median optimal imaging delay time was 91.3 seconds, with an interquartile range of 46.2 to 119.5 seconds. The median signal intensity difference ratios between the myometrium and endometrial cancer were 0.03, with an interquartile range of -0.01 to 0.06, on the pre-contrast MR imaging and 0.20, with an interquartile range of 0.15 to 0.25, on the post-contrast MR imaging. An imaging delay of approximately 90 seconds after initiating contrast material injection may be optimal for obtaining appropriate tumour-myometrium contrast in women with endometrial cancer. (orig.)

  12. Clinical utility of eco-color-power Doppler ultrasonography and contrast enhanced magnetic resonance imaging for interpretation and quantification of joint synovitis: a review.

    Science.gov (United States)

    Carotti, Marina; Galeazzi, Vittoria; Catucci, Francesca; Zappia, Marcello; Arrigoni, Francesco; Barile, Antonio; Giovagnoni, Andrea

    2018-01-19

    With the introduction of new biologics such as anti-TNF-alpha antibodies and other therapies in the treatment of inflammatory arthritis, capable of halting joint destruction and functional disability, there are new pressures on diagnostic and prognostic imaging. Early demonstration of pre-erosive inflammatory features and monitoring of the long-term effects of treatment are becoming increasingly important. Early detection of synovitis offers advantages in terms of allowing early instigation of therapy and may allow the identification of those patients displaying more aggressive disease who might benefit from early intervention with expensive DMARD therapy. Advanced imaging techniques such as ultrasound (US) and magnetic resonance imaging (MRI) have focussed on the demonstration and quantification of synovitis and allow early diagnosis of inflammatory arthropathies such as rheumatoid arthritis (RA) and psoriatic arthritis (PsA). Synovitis represents a potential surrogate measure of disease activity that can be monitored using either MRI or US; the techniques have, generally, focused on monitoring synovial volume or quality as assessed by its vascularity. However to achieve these goals, standardisation and validation of US and MRI are required to ensure accurate diagnosis, reproducibility and reliability. Each modality has different strengths and weaknesses and levels of validation. This article aims to increase the awareness of radiologists and rheumatologists about this field and to encourage them to participate and contribute to the ongoing development of these modalities. Without this collaboration, it is unlikely that these modalities will reach their full potential in the field of rheumatological imaging. This review is in two parts. The first part addresses the role of US and colour or power Doppler sonography (PDUS) in the detection and monitoring of synovitis in inflammatory arthropathies. The second part will look at advanced MR imaging and Dynamic contrast-enhanced

  13. Diffraction enhanced imaging of a rat model of gastric acid aspiration pneumonitis.

    Science.gov (United States)

    Connor, Dean M; Zhong, Zhong; Foda, Hussein D; Wiebe, Sheldon; Parham, Christopher A; Dilmanian, F Avraham; Cole, Elodia B; Pisano, Etta D

    2011-12-01

    Diffraction-enhanced imaging (DEI) is a type of phase contrast x-ray imaging that has improved image contrast at a lower dose than conventional radiography for many imaging applications, but no studies have been done to determine if DEI might be useful for diagnosing lung injury. The goals of this study were to determine if DEI could differentiate between healthy and injured lungs for a rat model of gastric aspiration and to compare diffraction-enhanced images with chest radiographs. Radiographs and diffraction-enhanced chest images of adult Sprague Dawley rats were obtained before and 4 hours after the aspiration of 0.4 mL/kg of 0.1 mol/L hydrochloric acid. Lung damage was confirmed with histopathology. The radiographs and diffraction-enhanced peak images revealed regions of atelectasis in the injured rat lung. The diffraction-enhanced peak images revealed the full extent of the lung with improved clarity relative to the chest radiographs, especially in the portion of the lower lobe that extended behind the diaphragm on the anteroposterior projection. For a rat model of gastric acid aspiration, DEI is capable of distinguishing between a healthy and an injured lung and more clearly than radiography reveals the full extent of the lung and the lung damage. Copyright © 2011 AUR. All rights reserved.

  14. Changes of renal blood flow after ESWL: Assessment by ASL MR imaging, contrast enhanced MR imaging, and renal resistive index

    Energy Technology Data Exchange (ETDEWEB)

    Abd Ellah, Mohamed, E-mail: dr_m_hamdy2006@hotmail.co [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Kremser, Christian, E-mail: christian.kremser@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Pallwein, Leo, E-mail: leo.pallwein-prettner@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Aigner, Friedrich, E-mail: friedrich.Aigner@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Schocke, Michael, E-mail: michael.schocke@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Peschel, Reinhard, E-mail: reinhard.peschel@uki.a [Innsbruck Medical University, Urology Dept., Anich St. 35, 6020 Innsbruck (Austria); Pedross, Florian, E-mail: florian.pedross@i-med.ac.a [Innsbruck Medical University, Medical Statistics Dept., Anich St. 35, 6020 Innsbruck (Austria); Pinggera, Germar-Michael, E-mail: germar.pinggera@uki.a [Innsbruck Medical University, Urology Dept., Anich St. 35, 6020 Innsbruck (Austria); Wolf, Christian, E-mail: christian.wolf@bkh-reutte.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Alsharkawy, Mostafa A.M., E-mail: drmostafamri@yahoo.co [Assiut University, Radiology Dept., Assiut (Egypt); Jaschke, Werner, E-mail: werner.jaschke@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Frauscher, Ferdinand, E-mail: ferdinand.frauscher@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria)

    2010-10-15

    The annual incidence of stone formation is increased in the industrialised world. Extracorporeal shockwave lithotripsy is a non-invasive effective treatment of upper urinary tract stones. This study is aimed to evaluate changes of renal blood flow in patients undergoing extracorporeal shock wave lithotripsy (ESWL) by arterial spin labeling (ASL) MR imaging, contrast enhanced dynamic MR imaging, and renal resistive index (RI). Thirteen patients with nephrolithiasis were examined using MR imaging and Doppler ultrasound 12 h before and 12 h after ESWL. ASL sequence was done for both kidneys and followed by contrast enhanced MR imaging. In addition RI Doppler ultrasound measurements were performed. A significant increase in RI (p < 0.001) was found in both treated and untreated kidneys. ASL MR imaging also showed significant changes in both kidneys (p < 0.001). Contrast enhanced dynamic MR imaging did not show significant changes in the kidneys. ESWL causes changes in RI and ASL MR imaging, which seem to reflect changes in renal blood flow.

  15. Bone surface enhancement in ultrasound images using a new Doppler-based acquisition/processing method

    Science.gov (United States)

    Yang, Xu; Tang, Songyuan; Tasciotti, Ennio; Righetti, Raffaella

    2018-01-01

    Ultrasound (US) imaging has long been considered as a potential aid in orthopedic surgeries. US technologies are safe, portable and do not use radiations. This would make them a desirable tool for real-time assessment of fractures and to monitor fracture healing. However, image quality of US imaging methods in bone applications is limited by speckle, attenuation, shadow, multiple reflections and other imaging artifacts. While bone surfaces typically appear in US images as somewhat ‘brighter’ than soft tissue, they are often not easily distinguishable from the surrounding tissue. Therefore, US imaging methods aimed at segmenting bone surfaces need enhancement in image contrast prior to segmentation to improve the quality of the detected bone surface. In this paper, we present a novel acquisition/processing technique for bone surface enhancement in US images. Inspired by elastography and Doppler imaging methods, this technique takes advantage of the difference between the mechanical and acoustic properties of bones and those of soft tissues to make the bone surface more easily distinguishable in US images. The objective of this technique is to facilitate US-based bone segmentation methods and improve the accuracy of their outcomes. The newly proposed technique is tested both in in vitro and in vivo experiments. The results of these preliminary experiments suggest that the use of the proposed technique has the potential to significantly enhance the detectability of bone surfaces in noisy ultrasound images.

  16. Bone surface enhancement in ultrasound images using a new Doppler-based acquisition/processing method.

    Science.gov (United States)

    Yang, Xu; Tang, Songyuan; Tasciotti, Ennio; Righetti, Raffaella

    2018-01-17

    Ultrasound (US) imaging has long been considered as a potential aid in orthopedic surgeries. US technologies are safe, portable and do not use radiations. This would make them a desirable tool for real-time assessment of fractures and to monitor fracture healing. However, image quality of US imaging methods in bone applications is limited by speckle, attenuation, shadow, multiple reflections and other imaging artifacts. While bone surfaces typically appear in US images as somewhat 'brighter' than soft tissue, they are often not easily distinguishable from the surrounding tissue. Therefore, US imaging methods aimed at segmenting bone surfaces need enhancement in image contrast prior to segmentation to improve the quality of the detected bone surface. In this paper, we present a novel acquisition/processing technique for bone surface enhancement in US images. Inspired by elastography and Doppler imaging methods, this technique takes advantage of the difference between the mechanical and acoustic properties of bones and those of soft tissues to make the bone surface more easily distinguishable in US images. The objective of this technique is to facilitate US-based bone segmentation methods and improve the accuracy of their outcomes. The newly proposed technique is tested both in in vitro and in vivo experiments. The results of these preliminary experiments suggest that the use of the proposed technique has the potential to significantly enhance the detectability of bone surfaces in noisy ultrasound images.

  17. Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

    Directory of Open Access Journals (Sweden)

    Fereydoon Nowshiravan Rahatabad

    2015-09-01

    Full Text Available Introduction One of the most important pre-processing steps in optical coherence tomography (OCT is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on OCT and test images. Objective evaluation of both types of images was performed, using various image metrics such as peak signal-to-noise ratio (PSNR, root mean square error, correlation coefficient and elapsed time. For the purpose of recovery, Kuan filter was used as an input for edge enhancement. Also, a spatial filter was applied to improve image quality. Results The obtained results were presented as statistical tables and images. Based on statistical measures and visual quality of OCT images, Enhanced Lee filter (3×3 with a PSNR value of 43.6735 in low noise variance and Kuan filter (3×3 with a PSNR value of 37.2850 in high noise variance showed superior performance over other filters. Conclusion Based on the obtained results, by using speckle reduction filters such as Enhanced Lee and Kuan filters on OCT images, the number of compounded images, required to achieve a given image quality, could be reduced. Moreover, use of Kuan filters for promoting the edges allowed smoothing of speckle regions, while preserving image tissue texture.

  18. Digital Enhancement of Night Vision and Thermal Images

    National Research Council Canada - National Science Library

    Teo, Chek

    2003-01-01

    .... This thesis explores the effect of the Contrast Limited Adaptive Histogram Equalization (CLAHE) process on night vision and thermal images With better contrast, target detection and discrimination can be improved...

  19. Enhancing contrast of magnetic resonance imaging in patients with ...

    African Journals Online (AJOL)

    DTPA), a recent magnetic resonance imaging (MRI) contrast agent, in hepatobiliary system of patients with liver cirrhosis. Methods: Liver cirrhosis patients that underwent contrast MRI examination at Renai Hospital, Taipei City, Taiwan were ...

  20. Iterative methods for dose reduction and image enhancement in tomography

    Science.gov (United States)

    Miao, Jianwei; Fahimian, Benjamin Pooya

    2012-09-18

    A system and method for creating a three dimensional cross sectional image of an object by the reconstruction of its projections that have been iteratively refined through modification in object space and Fourier space is disclosed. The invention provides systems and methods for use with any tomographic imaging system that reconstructs an object from its projections. In one embodiment, the invention presents a method to eliminate interpolations present in conventional tomography. The method has been experimentally shown to provide higher resolution and improved image quality parameters over existing approaches. A primary benefit of the method is radiation dose reduction since the invention can produce an image of a desired quality with a fewer number projections than seen with conventional methods.

  1. Medium resolution image fusion, does it enhance forest structure assessment

    CSIR Research Space (South Africa)

    Roberts, JW

    2008-07-01

    Full Text Available This research explored the potential benefits of fusing optical and Synthetic Aperture Radar (SAR) medium resolution satellite-borne sensor data for forest structural assessment. Image fusion was applied as a means of retaining disparate data...

  2. Heuristic Enhancement of Magneto-Optical Images for NDE

    Science.gov (United States)

    Cacciola, Matteo; Megali, Giuseppe; Pellicanò, Diego; Calcagno, Salvatore; Versaci, Mario; Morabito, FrancescoCarlo

    2010-12-01

    The quality of measurements in nondestructive testing and evaluation plays a key role in assessing the reliability of different inspection techniques. Each different technique, like the magneto-optic imaging here treated, is affected by some special types of noise which are related to the specific device used for their acquisition. Therefore, the design of even more accurate image processing is often required by relevant applications, for instance, in implementing integrated solutions for flaw detection and characterization. The aim of this paper is to propose a preprocessing procedure based on independent component analysis (ICA) to ease the detection of rivets and/or flaws in the specimens under test. A comparison of the proposed approach with some other advanced image processing methodologies used for denoising magneto-optic images (MOIs) is carried out, in order to show advantages and weakness of ICA in improving the accuracy and performance of the rivets/flaw detection.

  3. A Variable Order Fractional Differential-Based Texture Enhancement Algorithm with Application in Medical Imaging.

    Directory of Open Access Journals (Sweden)

    Qiang Yu

    Full Text Available Texture enhancement is one of the most important techniques in digital image processing and plays an essential role in medical imaging since textures discriminate information. Most image texture enhancement techniques use classical integral order differential mask operators or fractional differential mask operators using fixed fractional order. These masks can produce excessive enhancement of low spatial frequency content, insufficient enhancement of large spatial frequency content, and retention of high spatial frequency noise. To improve upon existing approaches of texture enhancement, we derive an improved Variable Order Fractional Centered Difference (VOFCD scheme which dynamically adjusts the fractional differential order instead of fixing it. The new VOFCD technique is based on the second order Riesz fractional differential operator using a Lagrange 3-point interpolation formula, for both grey scale and colour image enhancement. We then use this method to enhance photographs and a set of medical images related to patients with stroke and Parkinson's disease. The experiments show that our improved fractional differential mask has a higher signal to noise ratio value than the other fractional differential mask operators. Based on the corresponding quantitative analysis we conclude that the new method offers a superior texture enhancement over existing methods.

  4. Conjugated Polymer with Intrinsic Alkyne Units for Synergistically Enhanced Raman Imaging in Living Cells.

    Science.gov (United States)

    Li, Shengliang; Chen, Tao; Wang, Yunxia; Liu, Libing; Lv, Fengting; Li, Zhiliang; Huang, Yanyi; Schanze, Kirk S; Wang, Shu

    2017-10-16

    Development of Raman-active materials with enhanced and distinctive Raman vibrations in the Raman-silent region (1800-2800 cm -1 ) is highly required for specific molecular imaging of living cells with high spatial resolution. Herein, water-soluble cationic conjugated polymers (CCPs), poly(phenylene ethynylene) (PPE) derivatives, are explored for use as alkyne-state-dependent Raman probes for living cell imaging due to synergetic enhancement effect of alkyne vibrations in Raman-silent region compared to alkyne-containing small molecules. The enhanced alkyne signals result from the integration of alkyne groups into the rigid backbone and the delocalized π-conjugated structure. PPE-based conjugated polymer nanoparticles (CPNs) were also prepared as Raman-responsive nanomaterials for distinct imaging application. This work opens a new way into the development of conjugated polymer materials for enhanced Raman imaging. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Gd-EOB-DTPA-enhanced magnetic resonance imaging for bile duct intraductal papillary mucinous neoplasms

    OpenAIRE

    Ying, Shi-Hong; Teng, Xiao-Dong; Wang, Zhao-Ming; Wang, Qi-Dong; Zhao, Yi-Lei; Chen, Feng; Xiao, Wen-Bo

    2015-01-01

    AIM: To investigate gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) of intraductal papillary mucinous neoplasms of the bile duct (IPMN-B).

  6. Acute and chronic tears of anterior cruciate ligament : role of gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Lee, Eun Jung; Jee, Won Hee; Im, Soo A; Chun, Ho Jong; Jung, Hyun Seouk; Kim, Soo Young; Kwon, Tae An; Song, Sun Wha; Choi, Kyu Ho

    1998-01-01

    To evaluate the efficacy of fat-suppressed gadolinium-enhanced MR imaging in differentiating acute from chronic ligament tears of anterior cruciate ligament. Materials and Methods : MR images of 22 patients with arthroscopically proven complete tear of the anterior cruciate ligament were retrospectively reviewed. The interval between injury and MR examination was one day to seven years. When ligament tear was detected on MR image with three months of injury, the case was considered acute;if detected after three months had elapsed, it was judged to be chronic. The extent of contrast enhancement was graded as 1, 2 or 3; grade 1, enhancement was confined to the expected ligament region; grade 2, enhancement extended to the joint capsule; grade 3, enhancement extended beyond the joint capsule. The grades of contrast enhancement correlated with the acute and chronic stages of ligament tears. Associated bone bruise and/or adjacent soft tissue edema were also evaluated. Results : Among 15 patients with acute ligament tear, nine (60%) showed grade 3 enhancement; among seven in whom tearing was chronic, four (57%) showed grade 1 enhancement. Bone bruising was present in 100% of acute tears (15/15) and 29 % of chronic tears (2/7). Soft tissue edema was associated in 87% of acute tears (13/15) and 29% of chronic tears(2/7). Conclusion : Fat-suppressed gadolinium-enhanced MR imaging could help differentiate acute from chronic tears of anterior cruciate ligament, as well as bone bruising and tissue edema

  7. Enhanced speed in fluorescence imaging using beat frequency multiplexing

    Science.gov (United States)

    Mikami, Hideharu; Kobayashi, Hirofumi; Wang, Yisen; Hamad, Syed; Ozeki, Yasuyuki; Goda, Keisuke

    2016-03-01

    Fluorescence imaging using radiofrequency-tagged emission (FIRE) is an emerging technique that enables higher imaging speed (namely, temporal resolution) in fluorescence microscopy compared to conventional fluorescence imaging techniques such as confocal microscopy and wide-field microscopy. It works based on the principle that it uses multiple intensity-modulated fields in an interferometric setup as excitation fields and applies frequency-division multiplexing to fluorescence signals. Unfortunately, despite its high potential, FIRE has limited imaging speed due to two practical limitations: signal bandwidth and signal detection efficiency. The signal bandwidth is limited by that of an acousto-optic deflector (AOD) employed in the setup, which is typically 100-200 MHz for the spectral range of fluorescence excitation (400-600 nm). The signal detection efficiency is limited by poor spatial mode-matching between two interfering fields to produce a modulated excitation field. Here we present a method to overcome these limitations and thus to achieve higher imaging speed than the prior version of FIRE. Our method achieves an increase in signal bandwidth by a factor of two and nearly optimal mode matching, which enables the imaging speed limited by the lifetime of the target fluorophore rather than the imaging system itself. The higher bandwidth and better signal detection efficiency work synergistically because higher bandwidth requires higher signal levels to avoid the contribution of shot noise and amplifier noise to the fluorescence signal. Due to its unprecedentedly high-speed performance, our method has a wide variety of applications in cancer detection, drug discovery, and regenerative medicine.

  8. Enhanced pulsed magneto-motive ultrasound imaging using superparamagnetic nanoclusters

    International Nuclear Information System (INIS)

    Mehrmohammadi, M; Qu, M; Emelianov, S Y; Yoon, K Y; Johnston, K P

    2011-01-01

    Recently, pulsed magneto-motive ultrasound (pMMUS) imaging augmented with ultra-small magnetic nanoparticles has been introduced as a tool capable of imaging events at molecular and cellular levels. The sensitivity of a pMMUS system depends on several parameters, including the size, geometry and magnetic properties of the nanoparticles. Under the same magnetic field, larger magnetic nanostructures experience a stronger magnetic force and produce larger displacement, thus improving the sensitivity and signal-to-noise ratio (SNR) of pMMUS imaging. Unfortunately, large magnetic iron-oxide nanoparticles are typically ferromagnetic and thus are very difficult to stabilize against colloidal aggregation. In the current study we demonstrate improvement of pMMUS image quality by using large size superparamagnetic nanoclusters characterized by strong magnetization per particle. Water-soluble magnetic nanoclusters of two sizes (15 and 55 nm average size) were synthesized from 3 nm iron precursors in the presence of citrate capping ligand. The size distribution of synthesized nanoclusters and individual nanoparticles was characterized using dynamic light scattering (DLS) analysis and transmission electron microscopy (TEM). Tissue mimicking phantoms containing single nanoparticles and two sizes of nanoclusters were imaged using a custom-built pMMUS imaging system. While the magnetic properties of citrate-coated nanoclusters are identical to those of superparamagnetic nanoparticles, the magneto-motive signal detected from nanoclusters is larger, i.e. the same magnetic field produced larger magnetically induced displacement. Therefore, our study demonstrates that clusters of superparamagnetic nanoparticles result in pMMUS images with higher contrast and SNR.

  9. Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue

    International Nuclear Information System (INIS)

    Jakubek, Jan; Granja, Carlos; Dammer, Jiri; Hanus, Robert; Holy, Tomas; Pospisil, Stanislav; Tykva, Richard; Uher, Josef; Vykydal, Zdenek

    2007-01-01

    A tabletop system for digital high resolution and high sensitivity X-ray micro-radiography has been developed for small-animal and soft-tissue imaging. The system is based on a micro-focus X-ray tube and the semiconductor hybrid position sensitive Medipix2 pixel detector. Transmission radiography imaging, conventionally based only on absorption, is enhanced by exploiting phase-shift effects induced in the X-ray beam traversing the sample. Phase contrast imaging is realized by object edge enhancement. DAQ is done by a novel fully integrated USB-based readout with online image generation. Improved signal reconstruction techniques make use of advanced statistical data analysis, enhanced beam hardening correction and direct thickness calibration of individual pixels. 2D and 3D micro-tomography images of several biological samples demonstrate the applicability of the system for biological and medical purposes including in-vivo and time dependent physiological studies in the life sciences

  10. Digital staining for histopathology multispectral images by the combined application of spectral enhancement and spectral transformation.

    Science.gov (United States)

    Bautista, Pinky A; Yagi, Yukako

    2011-01-01

    In this paper we introduced a digital staining method for histopathology images captured with an n-band multispectral camera. The method consisted of two major processes: enhancement of the original spectral transmittance and the transformation of the enhanced transmittance to its target spectral configuration. Enhancement is accomplished by shifting the original transmittance with the scaled difference between the original transmittance and the transmittance estimated with m dominant principal component (PC) vectors;the m-PC vectors were determined from the transmittance samples of the background image. Transformation of the enhanced transmittance to the target spectral configuration was done using an nxn transformation matrix, which was derived by applying a least square method to the enhanced and target spectral training data samples of the different tissue components. Experimental results on the digital conversion of a hematoxylin and eosin (H&E) stained multispectral image to its Masson's trichrome stained (MT) equivalent shows the viability of the method.

  11. Characterization of the enhancing lesions on dynamic contrast enhanced magnetic resonance imaging in patients with interstitial mammoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Yun [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Sung Hun, E-mail: rad-ksh@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kang, Bong Joo [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Hyeon Sook [Department of Radiology, St. Paul Hospital, The Catholic University of Korea (Korea, Republic of); Cha, Eun Suk [Department of Radiology, Ewha Womans University, School of Medicine, Mokdong Hospital (Korea, Republic of); Kim, Ji Youn [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Song, Byung Joo [Department of Surgery, Seoul St. Mary' s Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)

    2013-12-01

    Purpose: The purpose of this study was to categorize the morphologic and kinetic features of enhancing lesions in breasts with interstitial mammoplasty using dynamic contrast-enhanced magnetic resonance imaging and to assess factors predictive of breast cancer. Materials and methods: We retrospectively reviewed the clinical and radiological data of 21 enhancing lesions in 19 patients with interstitial mammoplasty, who underwent breast magnetic resonance imaging and biopsy or an operation in our hospital from September 2008 to July 2012. These lesions were sorted by morphological and kinetic features and final assessment category according to the BI-RADS lexicon. Results: Nine cases were confirmed to be ductal carcinoma in situ (n = 2) and invasive ductal carcinoma (n = 7), and the remaining 12 cases were fibrocystic disease (n = 2), fibroadenoma (n = 2), fat necrosis (n = 1), foreign body granuloma (n = 3) and silicone mastitis (n = 1). Common features of malignancy included irregular shape (50.0%), spiculated margins (75.0%), heterogeneous enhancement (50.0%) and type III kinetic pattern (87.5%). The correlations of margins and kinetic curve pattern with benignity and malignancy approached statistical significance (p = 0.02, respectively). We found no correlation for shape (p = 0.33) or internal enhancement (p = 0.42) between lesion types. The malignancy rate of enhancing lesions was 42.8% (9/21). The sensitivity and specificity of dynamic contrast-enhanced magnetic resonance imaging were 100% and 16.67%, respectively. The positive predictive value, negative predictive value and accuracy of magnetic resonance imaging were 47.38%, 100% and 52.38%. Overall inter-observer agreement for the kinetic curve pattern was good (κ = 0.67). Moderate agreement was seen in describing the shape, margin, enhancement and assessing the final category (κ = 0.59, 0.46, 0.58 and 0.49, respectively). Conclusion: Dynamic contrast-enhanced magnetic resonance imaging had a high

  12. Characterization of the enhancing lesions on dynamic contrast enhanced magnetic resonance imaging in patients with interstitial mammoplasty

    International Nuclear Information System (INIS)

    Kim, Tae Yun; Kim, Sung Hun; Kang, Bong Joo; Kim, Hyeon Sook; Cha, Eun Suk; Kim, Ji Youn; Song, Byung Joo

    2013-01-01

    Purpose: The purpose of this study was to categorize the morphologic and kinetic features of enhancing lesions in breasts with interstitial mammoplasty using dynamic contrast-enhanced magnetic resonance imaging and to assess factors predictive of breast cancer. Materials and methods: We retrospectively reviewed the clinical and radiological data of 21 enhancing lesions in 19 patients with interstitial mammoplasty, who underwent breast magnetic resonance imaging and biopsy or an operation in our hospital from September 2008 to July 2012. These lesions were sorted by morphological and kinetic features and final assessment category according to the BI-RADS lexicon. Results: Nine cases were confirmed to be ductal carcinoma in situ (n = 2) and invasive ductal carcinoma (n = 7), and the remaining 12 cases were fibrocystic disease (n = 2), fibroadenoma (n = 2), fat necrosis (n = 1), foreign body granuloma (n = 3) and silicone mastitis (n = 1). Common features of malignancy included irregular shape (50.0%), spiculated margins (75.0%), heterogeneous enhancement (50.0%) and type III kinetic pattern (87.5%). The correlations of margins and kinetic curve pattern with benignity and malignancy approached statistical significance (p = 0.02, respectively). We found no correlation for shape (p = 0.33) or internal enhancement (p = 0.42) between lesion types. The malignancy rate of enhancing lesions was 42.8% (9/21). The sensitivity and specificity of dynamic contrast-enhanced magnetic resonance imaging were 100% and 16.67%, respectively. The positive predictive value, negative predictive value and accuracy of magnetic resonance imaging were 47.38%, 100% and 52.38%. Overall inter-observer agreement for the kinetic curve pattern was good (κ = 0.67). Moderate agreement was seen in describing the shape, margin, enhancement and assessing the final category (κ = 0.59, 0.46, 0.58 and 0.49, respectively). Conclusion: Dynamic contrast-enhanced magnetic resonance imaging had a high

  13. Degeneration of uterine leiomyoma: comparison between Gd-DTPA enhanced MR imaging and pathologic findings

    International Nuclear Information System (INIS)

    Shin, M. J.; Kim, G. W.; No, T. Y.; Ahn, W. H.; Baik, S. K.; Kim, B. G.; Choi, H. Y.; Paik, O. J.

    1995-01-01

    Gonadotropin-releasing hormone(GnRH) analogues have been used as a conservative or preoperative therapy in the treatment of uterine leiomyoma. Since these drugs, which can induce a low estrogenic state, affect only undegenerative leiomyoma tissue, the aim of the present study was to differentiate degenerative leiomyoma from undegenerative one by Gd-DTPA enhanced magnetic resonance imaging(MRI). There were 40 masses in 24 patients; all were diagnosed by surgical-pathology. With superconductive 0.5T MR circuit, T1-and T2-weighted images and Gd-DTPA T1-weighted images were obtained. Based on a combination of signal intensities of T2-weighted and enhanced T1 weighted image on the same tumor section all the lesions were classified to one of four MRI patterns. Pattern I was a heterogeneous hyperintensity on the T2-weighted images that was enhancement by Gd-DTPA. Pattern II was a high signal intensity on the T2-weighted MR images but no enhancement by Gd-DTPA. Pattern III was a low to intermediate signal intensity on the T2-weighted MR images and enhancement on the Gd-DTPA T1-weighted images. Pattern IV was a low to intermediate signal intensity on the T2-weighted images and no enhancement by Gd-DTPA. Each of these 4 groups of MRI pattern were co-related to the surgical-pathology findings. Pathologically, pattern I corresponded to an edematous leiomyoma in 3 cases and a connective tissue leiomyoma in one case. Pattern II corresponded to three red degeneration, two cystic degeneration and one infected leiomyoma. Pattern III corresponded to eighteen undegenerative leiomyomas, but some of them showed focal connective tissue proliferation. All of twelve cases in pattern IV corresponded to a hyaline degeneration. MRI with Gd-DTPA enhancement may differentiate undegenerative leiomyoma from degenerated one

  14. Degeneration of uterine leiomyoma: comparison between Gd-DTPA enhanced MR imaging and pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Shin, M. J.; Kim, G. W.; No, T. Y.; Ahn, W. H.; Baik, S. K.; Kim, B. G.; Choi, H. Y.; Paik, O. J. [Wallace Memorial Baptist Hospital, Busan (Korea, Republic of)

    1995-05-15

    Gonadotropin-releasing hormone(GnRH) analogues have been used as a conservative or preoperative therapy in the treatment of uterine leiomyoma. Since these drugs, which can induce a low estrogenic state, affect only undegenerative leiomyoma tissue, the aim of the present study was to differentiate degenerative leiomyoma from undegenerative one by Gd-DTPA enhanced magnetic resonance imaging(MRI). There were 40 masses in 24 patients; all were diagnosed by surgical-pathology. With superconductive 0.5T MR circuit, T1-and T2-weighted images and Gd-DTPA T1-weighted images were obtained. Based on a combination of signal intensities of T2-weighted and enhanced T1 weighted image on the same tumor section all the lesions were classified to one of four MRI patterns. Pattern I was a heterogeneous hyperintensity on the T2-weighted images that was enhancement by Gd-DTPA. Pattern II was a high signal intensity on the T2-weighted MR images but no enhancement by Gd-DTPA. Pattern III was a low to intermediate signal intensity on the T2-weighted MR images and enhancement on the Gd-DTPA T1-weighted images. Pattern IV was a low to intermediate signal intensity on the T2-weighted images and no enhancement by Gd-DTPA. Each of these 4 groups of MRI pattern were co-related to the surgical-pathology findings. Pathologically, pattern I corresponded to an edematous leiomyoma in 3 cases and a connective tissue leiomyoma in one case. Pattern II corresponded to three red degeneration, two cystic degeneration and one infected leiomyoma. Pattern III corresponded to eighteen undegenerative leiomyomas, but some of them showed focal connective tissue proliferation. All of twelve cases in pattern IV corresponded to a hyaline degeneration. MRI with Gd-DTPA enhancement may differentiate undegenerative leiomyoma from degenerated one.

  15. Protocol-based care: the standardisation of decision-making?

    Science.gov (United States)

    Rycroft-Malone, Jo; Fontenla, Marina; Seers, Kate; Bick, Debra

    2009-05-01

    To explore how protocol-based care affects clinical decision-making. In the context of evidence-based practice, protocol-based care is a mechanism for facilitating the standardisation of care and streamlining decision-making through rationalising the information with which to make judgements and ultimately decisions. However, whether protocol-based care does, in the reality of practice, standardise decision-making is unknown. This paper reports on a study that explored the impact of protocol-based care on nurses' decision-making. Theoretically informed by realistic evaluation and the promoting action on research implementation in health services framework, a case study design using ethnographic methods was used. Two sites were purposively sampled; a diabetic and endocrine unit and a cardiac medical unit. Within each site, data collection included observation, postobservation semi-structured interviews with staff and patients, field notes, feedback sessions and document review. Data were inductively and thematically analysed. Decisions made by nurses in both sites were varied according to many different and interacting factors. While several standardised care approaches were available for use, in reality, a variety of information sources informed decision-making. The primary approach to knowledge exchange and acquisition was person-to-person; decision-making was a social activity. Rarely were standardised care approaches obviously referred to; nurses described following a mental flowchart, not necessarily linked to a particular guideline or protocol. When standardised care approaches were used, it was reported that they were used flexibly and particularised. While the logic of protocol-based care is algorithmic, in the reality of clinical practice, other sources of information supported nurses' decision-making process. This has significant implications for the political goal of standardisation. The successful implementation and judicious use of tools such as

  16. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    International Nuclear Information System (INIS)

    Looe, H.K.; Uphoff, Y.; Poppe, B.; Carl von Ossietzky Univ., Oldenburg; Harder, D.; Willborn, K.C.

    2012-01-01

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  17. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    Energy Technology Data Exchange (ETDEWEB)

    Looe, H.K.; Uphoff, Y.; Poppe, B. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy; Carl von Ossietzky Univ., Oldenburg (Germany). WG Medical Radiation Physics; Harder, D. [Georg August Univ., Goettingen (Germany). Medical Physics and Biophysics; Willborn, K.C. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy

    2012-02-15

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  18. Image segmentation for enhancing symbol recognition in prosthetic vision.

    Science.gov (United States)

    Horne, Lachlan; Barnes, Nick; McCarthy, Chris; He, Xuming

    2012-01-01

    Current and near-term implantable prosthetic vision systems offer the potential to restore some visual function, but suffer from poor resolution and dynamic range of induced phosphenes. This can make it difficult for users of prosthetic vision systems to identify symbolic information (such as signs) except in controlled conditions. Using image segmentation techniques from computer vision, we show it is possible to improve the clarity of such symbolic information for users of prosthetic vision implants in uncontrolled conditions. We use image segmentation to automatically divide a natural image into regions, and using a fixation point controlled by the user, select a region to phosphenize. This technique improves the apparent contrast and clarity of symbolic information over traditional phosphenization approaches.

  19. Lumbosacral lipoma : gadolinium-enhanced fat saturation T1 weighted MR image is necessary?

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyun Chul; Chung, Tae Woong; Seo, Jeong Jin; Chung, Gwang Woo; Kim, Yun Hyeon; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of contrast-enhanced fat saturation T1-weighted imaging for the evaluation of spinal lipoma, compared with clinical symptoms and surgical findings. Ten patients with lipomyelomeningocele, confirmed by surgery, were included in this study. In all cases, conventional spin echo T1-and T2-weighted MR imaging, and contrast-enhanced fat saturation T1-weighted imaging was performed to evaluate clinical symptoms, the position of the conus medullaris, the presence of cord tethering, and associated anomalies, and to compare the relative usefulness of the techniques. All ten patients were suffering from lipomyelomeningocele without filum terminale fibrolipoma or intradural lipoma. All cases were associated with cord tethering. As associated anomalies, there were seven cases of syringomyelia without hydrocephalus or anorectal anomaly. To evaluate the position of the spinal conus and the presence of cord tethering, conventional T1-weighted imaging was more useful than the contrast-enhanced fat saturation equivalent. In patients with early-stage spinal lipoma, MRI is useful for evaluation of the causes and position of cord tethering and associated anomalies Our results suggest that contrast-enhanced fat saturation T1-weighted images do not provide additional information concerning spinal lipoma, and that for the diagnosis of this condition, conventional T1 and T2-weighted images are more useful than those obtained by contrast-enhanced fat saturation T1-weighted imaging

  20. METHOD OF IMAGE QUALITY ENHANCEMENT FOR SPACE OBJECTS

    Directory of Open Access Journals (Sweden)

    D. S. Korshunov

    2014-07-01

    Full Text Available The paper deals with an approach for image quality improvement of the space objects in the visible range of electromagnetic wave spectrum. The proposed method is based on the joint taking into account of both the motion velocity of the space supervisory apparatus and a space object observed in the near-earth space when the time of photo-detector exposure is chosen. The timing of exposure is carried out by light-signal characteristics, which determines the optimal value of the charge package formed in the charge-coupled device being irradiated. Thus, the parameters of onboard observation equipment can be selected, which provides space images suitable for interpretation. The linear resolving capacity is used as quality indicator for space images, giving a complete picture for the image contrast and geometric properties of the object on the photo. Observation scenario modeling of the space object, done by sputnik-inspector, has shown the possibility of increasing the linear resolution up to10% - 20% or up to 40% - 50% depending on the non-complanarity angle at the movement along orbits. The proposed approach to the increase of photographs quality provides getting sharp and highcontrast images of space objects by the optical-electronic equipment of the space-based remote sensing. The usage of these images makes it possible to detect in time the space technology failures, which are the result of its exploitation in the nearearth space. The proposed method can be also applied at the stage of space systems design for optical-electronic surveillance in computer models used for facilities assessment of the shooting equipment information tract.

  1. Nanoscale imaging of photocurrent enhancement by resonator array photovoltaic coatings

    Science.gov (United States)

    Ha, Dongheon; Yoon, Yohan; Zhitenev, Nikolai B.

    2018-04-01

    Nanoscale surface patterning commonly used to increase absorption of solar cells can adversely impact the open-circuit voltage due to increased surface area and recombination. Here, we demonstrate absorptivity and photocurrent enhancement using silicon dioxide (SiO2) nanosphere arrays on a gallium arsenide (GaAs) solar cell that do not require direct surface patterning. Due to the combined effects of thin-film interference and whispering gallery-like resonances within nanosphere arrays, there is more than 20% enhancement in both absorptivity and photocurrent. To determine the effect of the resonance coupling between nanospheres, we perform a scanning photocurrent microscopy based on a near-field scanning optical microscopy measurement and find a substantial local photocurrent enhancement. The nanosphere-based antireflection coating (ARC), made by the Meyer rod rolling technique, is a scalable and a room-temperature process; and, can replace the conventional thin-film-based ARCs requiring expensive high-temperature vacuum deposition.

  2. Temporal adaptation enhances efficient contrast gain control on natural images.

    Directory of Open Access Journals (Sweden)

    Fabian Sinz

    Full Text Available Divisive normalization in primary visual cortex has been linked to adaptation to natural image statistics in accordance to Barlow's redundancy reduction hypothesis. Using recent advances in natural image modeling, we show that the previously studied static model of divisive normalization is rather inefficient in reducing local contrast correlations, but that a simple temporal contrast adaptation mechanism of the half-saturation constant can substantially increase its efficiency. Our findings reveal the experimentally observed temporal dynamics of divisive normalization to be critical for redundancy reduction.

  3. Local gray level S-curve transformation - A generalized contrast enhancement technique for medical images.

    Science.gov (United States)

    Gandhamal, Akash; Talbar, Sanjay; Gajre, Suhas; Hani, Ahmad Fadzil M; Kumar, Dileep

    2017-04-01

    Most medical images suffer from inadequate contrast and brightness, which leads to blurred or weak edges (low contrast) between adjacent tissues resulting in poor segmentation and errors in classification of tissues. Thus, contrast enhancement to improve visual information is extremely important in the development of computational approaches for obtaining quantitative measurements from medical images. In this research, a contrast enhancement algorithm that applies gray-level S-curve transformation technique locally in medical images obtained from various modalities is investigated. The S-curve transformation is an extended gray level transformation technique that results into a curve similar to a sigmoid function through a pixel to pixel transformation. This curve essentially increases the difference between minimum and maximum gray values and the image gradient, locally thereby, strengthening edges between adjacent tissues. The performance of the proposed technique is determined by measuring several parameters namely, edge content (improvement in image gradient), enhancement measure (degree of contrast enhancement), absolute mean brightness error (luminance distortion caused by the enhancement), and feature similarity index measure (preservation of the original image features). Based on medical image datasets comprising 1937 images from various modalities such as ultrasound, mammograms, fluorescent images, fundus, X-ray radiographs and MR images, it is found that the local gray-level S-curve transformation outperforms existing techniques in terms of improved contrast and brightness, resulting in clear and strong edges between adjacent tissues. The proposed technique can be used as a preprocessing tool for effective segmentation and classification of tissue structures in medical images. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Visualization: A Tool for Enhancing Students' Concept Images of Basic Object-Oriented Concepts

    Science.gov (United States)

    Cetin, Ibrahim

    2013-01-01

    The purpose of this study was twofold: to investigate students' concept images about class, object, and their relationship and to help them enhance their learning of these notions with a visualization tool. Fifty-six second-year university students participated in the study. To investigate his/her concept images, the researcher developed a survey…

  5. Thallium reinjection after stress-redistribution imaging. Does 24-hour delayed imaging after reinjection enhance detection of viable myocardium

    International Nuclear Information System (INIS)

    Dilsizian, V.; Smeltzer, W.R.; Freedman, N.M.; Dextras, R.; Bonow, R.O.

    1991-01-01

    Thallium reinjection immediately after conventional stress-redistribution imaging improves the detection of viable myocardium, as many myocardial regions with apparently 'irreversible' thallium defects on standard 3-4-hour redistribution images manifest enhanced thallium uptake after reinjection. Because the 10-minute period between reinjection and imaging may be too short, the present study was designed to determine whether 24-hour imaging after thallium reinjection provides additional information regarding myocardial viability beyond that obtained by imaging shortly after reinjection. We studied 50 patients with chronic stable coronary artery disease undergoing exercise thallium tomography, radionuclide angiography, and coronary arteriography. Immediately after the 3-4-hour redistribution images were obtained, 1 mCi thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. The stress, redistribution, reinjection, and 24-hour images were then analyzed qualitatively and quantitatively. Of the 127 abnormal myocardial regions on the stress images, 55 had persistent defects on redistribution images by qualitative analysis, of which 25 (45%) demonstrated improved thallium uptake after reinjection. At the 24-hour study, 23 of the 25 regions (92%) with previously improved thallium uptake by reinjection showed no further improvement. Similarly, of the 30 regions determined to have irreversible defects after reinjection, 29 (97%) remained irreversible on 24-hour images. These findings were confirmed by the quantitative analysis. The mean normalized thallium activity in regions with enhanced thallium activity after reinjection increased from 57 +/- 13% on redistribution studies to 70 +/- 14% after reinjection but did not change at 24 hours (71 +/- 14%)

  6. Gadopentetate-dimeglumine-enhanced MR imaging of osteonecrosis and osteochondritis dissecans of the elbow: initial experience

    International Nuclear Information System (INIS)

    Peiss, J.; Adam, G.; Casser, R.; Urhahn, R.; Guenther, R.W.

    1995-01-01

    Magnetic resonance imaging (MRI) was performed on seven patients with aseptic osteonecrosis (n=4) and osteochondritis dissecans (OCD; n=3) of the elbow. Precontrast MRI was superior to plain radiographs, which did not show any abnormality in three cases of osteonecrosis. On gadopentetate-dimeglumine-enhanced T1-weighted images, which were obtained in three patients with osteonecrosis and three patients with OCD, all cases of osteonecrosis demonstrated homogeneous enhancement of the lesions. All cases of OCD were diagnosed on plain radiographs. On MRI one showed significant enhancement of the loose body. In another case an incompletely enhancing loose body was surrounded by a diffusely enhancing region. In the third patient only a small marginal enhancement of the defect was observed. Our results suggest that MRI can improve the accuracy in diagnosis of aseptic osteonecrosis of the elbow. The use of gadopentetate dimeglumine allows the viability of the lesions or the loose bodies to be demonstrated and reparative tissue to be detected. (orig.)

  7. Gadoxetic acid disodium-enhanced MR imaging of cholangiolocellular carcinoma of the liver. Imaging characteristics and histopathological correlations

    Energy Technology Data Exchange (ETDEWEB)

    Haradome, Hiroki; Toda, Yusuke [Nihon University School of Medicine, Department of Radiology, Tokyo (Japan); Unno, Toshiyuki [Showa General Hospital, Department of Radiology, Koganei (Japan); Morisaka, Hiroyuki; Ichikawa, Tomoaki [Saitama Medical University International Medical Center, Department of Radiology, Saitama (Japan); Kwee, Thomas C. [UMC Groningen, Department of Radiology, Groningen (Netherlands); Kondo, Hiroshi [Teikyo University School of Medicine, Department of Radiology, Tokyo (Japan); Sano, Keiji [Teikyo University School of Medicine, Department of Surgery, Tokyo (Japan); Kondo, Fukuo [Teikyo University Hospital, Department of Pathology, Tokyo (Japan); Sugitani, Masahiko [Nihon University School of Medicine, Department of Pathology, Tokyo (Japan); Takayama, Tadatoshi [Nihon University School of Medicine, Department of Digestive Surgery, Tokyo (Japan)

    2017-11-15

    To review the gadoxetic acid disodium (EOB)-enhanced magnetic resonance (MR) imaging features of cholangiolocellular carcinoma (CoCC) of the liver and compare them with those of hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC). EOB-enhanced MR images of 19 patients with CoCC, 23 with ICC, and 51 with HCC were retrospectively evaluated qualitatively and quantitatively. Univariate and multivariate analyses were performed to determine the characteristic MR features of CoCC with histopathological-imaging correlation. Multivariate logistic regression analysis showed that dot-/band-shaped internal enhancement during the arterial and portal phases (P < 0.001), and larger arterial ring enhancement ratio (CoCC, 0.13 ± 0.04; ICC, 0.074 ± 0.04; P = 0.013) were significantly independently associated with CoCC in contrast to ICC, whereas several MR features including progressive enhancement during the portal and late phases (P < 0.001), target appearance in the hepatocyte phase (P = 0.004), and vessel penetration (P = 0.013) were significantly more frequently associated with CoCC than HCC. The dot-/band-like internal enhancement (78.9% of CoCCs) histopathologically corresponded to the tumour cell nest with vascular proliferations and retained Glisson's sheath structure. EOB-enhanced MR features of CoCC largely differ from those of HCC but are similar to those of ICC. However, the finding of thicker arterial ring enhancement with dot-/band-like internal enhancement could help differentiate CoCC from ICC. (orig.)

  8. Enhancing the Teaching and Learning of Mathematical Visual Images

    Science.gov (United States)

    Quinnell, Lorna

    2014-01-01

    The importance of mathematical visual images is indicated by the introductory paragraph in the Statistics and Probability content strand of the Australian Curriculum, which draws attention to the importance of learners developing skills to analyse and draw inferences from data and "represent, summarise and interpret data and undertake…

  9. Contrast-enhanced magnetic resonance imaging of the breast: the value of pharmacokinetic parameters derived from fast dynamic imaging during initial enhancement in classifying lesions

    International Nuclear Information System (INIS)

    Veltman, J.; Stoutjesdijk, M.; Mann, R.; Huisman, H.J.; Barentsz, J.O.; Blickman, J.G.; Boetes, C.

    2008-01-01

    The value of pharmacokinetic parameters derived from fast dynamic imaging during initial enhancement in characterizing breast lesions on magnetic resonance imaging (MRI) was evaluated. Sixty-eight malignant and 34 benign lesions were included. In the scanning protocol, high temporal resolution imaging was combined with high spatial resolution imaging. The high temporal resolution images were recorded every 4.1 s during initial enhancement (fast dynamic analysis). The high spatial resolution images were recorded at a temporal resolution of 86 s (slow dynamic analysis). In the fast dynamic evaluation pharmacokinetic parameters (K trans , V e and k ep ) were evaluated. In the slow dynamic analysis, each lesion was scored according to the BI-RADS classification. Two readers evaluated all data prospectively. ROC and multivariate analysis were performed. The slow dynamic analysis resulted in an AUC of 0.85 and 0.83, respectively. The fast dynamic analysis resulted in an AUC of 0.83 in both readers. The combination of both the slow and fast dynamic analyses resulted in a significant improvement of diagnostic performance with an AUC of 0.93 and 0.90 (P = 0.02). The increased diagnostic performance found when combining both methods demonstrates the additional value of our method in further improving the diagnostic performance of breast MRI. (orig.)

  10. Digital contrast enhancement of 18Fluorine-fluorodeoxyglucose positron emission tomography images in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Agarwal, Krishan Kant; Sharma, Punit; Bal, Chandrasekhar; Kumar, Rakesh

    2016-01-01

    The role of 18 fluorodeoxyglucose positron emission tomography (PET) is limited for detection of primary hepatocellular carcinoma (HCC) due to low contrast to the tumor, and normal hepatocytes (background). The aim of the present study was to improve the contrast between the tumor and background by standardizing the input parameters of a digital contrast enhancement technique. A transverse slice of PET image was adjusted for the best possible contrast, and saved in JPEG 2000 format. We processed this image with a contrast enhancement technique using 847 possible combinations of input parameters (threshold “m” and slope “e”). The input parameters which resulted in an image having a high value of 2 nd order entropy, and edge content, and low value of absolute mean brightness error, and saturation evaluation metrics, were considered as standardized input parameters. The same process was repeated for total nine PET-computed tomography studies, thus analyzing 7623 images. The selected digital contrast enhancement technique increased the contrast between the HCC tumor and background. In seven out of nine images, the standardized input parameters “m” had values between 150 and 160, and for other two images values were 138 and 175, respectively. The value of slope “e” was 4 in 4 images, 3 in 3 images and 1 in 2 images. It was found that it is important to optimize the input parameters for the best possible contrast for each image; a particular value was not sufficient for all the HCC images. The use of above digital contrast enhancement technique improves the tumor to background ratio in PET images of HCC and appears to be useful. Further clinical validation of this finding is warranted

  11. Mechanical assessment of bovine pericardium using Müeller matrix imaging, enhanced backscattering and digital image correlation analysis.

    Science.gov (United States)

    Cuando-Espitia, Natanael; Sánchez-Arévalo, Francisco; Hernández-Cordero, Juan

    2015-08-01

    Mechanical characterization of tissue is an important but complex task. We demonstrate the simultaneous use of Mueller matrix imaging (MMI), enhanced backscattering (EBS) and digital image correlation (DIC) in a bovine pericardium (BP) tensile test. The interest in BP relies on its wide use as valve replacement and biological patch. We show that the mean free path (MFP), obtained through EBS measurements, can be used as an indicator of the anisotropy of the fiber ensemble. Our results further show a good correlation between retardance images and displacement vector fields, which are intrinsically related with the fiber interaction within the tissue.

  12. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi, E-mail: k-takano@fukuoka-u.ac.jp; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-15

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  13. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    International Nuclear Information System (INIS)

    Takano, Koichi; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-01

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  14. Clinical significance of nerve root enhancement in contrast-enhanced MR imaging of the postoperative lumbar spine

    International Nuclear Information System (INIS)

    Lee, Yeon Soo; Lee, Eun Ja; Kang, Si Won; Choi, Eun Seok; Song, Chang June; Kim, Jong Chul

    2001-01-01

    To determine the significance of nerve root contrast enhancement in patients with residual or recurrent symptomatic postoperative lumbar spine. Eighty-eight patients with 116 postoperative lumbar disc lesions causing radiating back pain underwent enhanced MR imaging. Intradural nerve root enhancement was quantified by pixel measurement, and affected nerve roots were compared before and after contrast administration. Extradural nerve root enhancement was assessed visually, and nerve root enhancement and clinical symptoms were correlated. Associated lesions such as recurrent disc herniation, scar tissue, nerve root thickening and nerve root displacement were also evaluated. Of 26 cases (22.4%) involving intradural nerve root enhancement, 22 (84.6%) showed significant clinical symptoms (p=0.002). and of 59 (50.9%) demonstrating extradural enhancement, clinical symptoms showed significant correlation in 47 (79.7%) (p=0.001). Nerve root enhancement, including eleven cases where this was both intra-and extradural, showed highly significant association with clinical symptoms in 74 of the 116 cases (63.8%) (p=0.000). Among 33 cases (28.4%) of recurrent disc herniation, nerve root enhancement was observed in 28 (84.8%) and in 24 of these 28 (85.7%), significant correlation with clinical symptoms was observed (p=0.000). Where epidural fibrosis was present, correlation between nerve root enhancement and clinical symptoms was not significant (p>0.05). Nerve root thickening and displaced nerve root were, however, significantly associated with symptoms (87.2% and 88.6%, respectively). In patients with postoperative lumbar spine, the association between nerve root enhancement revealed by MRI and clinical symptoms was highly significant

  15. Pathologic contrast enhancement of cerebral lesions: A comparative study using stereotactic CT, stereotactic MR imaging, and stereotactic biopsy

    International Nuclear Information System (INIS)

    Earnest, F. IV; Kelly, P.J.; Scheithauer, B.; Kall, B.; Cascino, T.L.; Ehman, R.L.; Forbes, G.

    1986-01-01

    The author compared the pattern and degree of Gd-DTPA dimeglumine contrast enhancement demonstrated on stereotactic MR images with that seen on stereotactic CT images obtained after conventional iodinated contrast agent enhancement and with histopathologic findings on sequential stereotactic brain biopsies. Stereotactic biopsies of the areas that enhanced on CT or MR imaging revealed tumor tissue with neovascularity. Tumor tissue with no or mild neovascularity did not enhance with contrast agent administration. Isolated tumor cells were frequently found beyond the margins of some primary brain neoplasms defined by contrast agent-enhanced MR imaging and CT. The histopathologic findings associated with pathologic contrast agent enhancement are presented

  16. Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms

    International Nuclear Information System (INIS)

    Sidky, Emil Y.; Pan Xiaochuan; Reiser, Ingrid S.; Nishikawa, Robert M.; Moore, Richard H.; Kopans, Daniel B.

    2009-01-01

    Purpose: The authors develop a practical, iterative algorithm for image-reconstruction in undersampled tomographic systems, such as digital breast tomosynthesis (DBT). Methods: The algorithm controls image regularity by minimizing the image total p variation (TpV), a function that reduces to the total variation when p=1.0 or the image roughness when p=2.0. Constraints on the image, such as image positivity and estimated projection-data tolerance, are enforced by projection onto convex sets. The fact that the tomographic system is undersampled translates to the mathematical property that many widely varied resultant volumes may correspond to a given data tolerance. Thus the application of image regularity serves two purposes: (1) Reduction in the number of resultant volumes out of those allowed by fixing the data tolerance, finding the minimum image TpV for fixed data tolerance, and (2) traditional regularization, sacrificing data fidelity for higher image regularity. The present algorithm allows for this dual role of image regularity in undersampled tomography. Results: The proposed image-reconstruction algorithm is applied to three clinical DBT data sets. The DBT cases include one with microcalcifications and two with masses. Conclusions: Results indicate that there may be a substantial advantage in using the present image-reconstruction algorithm for microcalcification imaging.

  17. Role of intensity transformation function for enhancement of bone scintigraphic images.

    Science.gov (United States)

    Pandey, Anil Kumar; Dhiman, Vishali; Sharma, Akshima; ArunRaj, Sreedharan Thankarajan; Baghel, Vivek; Patel, Chetan; Sharma, Param Dev; Bal, Chandrasekhar; Kumar, Rakesh

    2018-03-29

    The bone scintigraphic image might exceed the dynamic range (the ratio between the highest and the lowest brightness a monitor is capable of displaying) of display monitor. In this case, a high intensity area, and loss of the details of other structures in the displayed image makes the clinical interpretation a challenging task. We have investigated the role of intensity transformation function for enhancement of these types of images. Methods: Forty high dynamic range bone scintigraphic images were processed using intensity transformation (IT) function. The IT function has two parameters: threshold and slope. Keeping the threshold equal to mean counts of the image, the value of slope was varied from 1 to 20. In-house application program written in MATLAB R2013b was used to process images. Twenty output images corresponding to one input image were visually inspected by two experienced nuclear medicine (NM) physicians to select diagnostic quality images, and from their selection the standardized slope (value of slope parameter) that produced maximum numbers of diagnostic images was determined. They also rated the image quality of input and output images (at standardized slope) on scale 1 to 5 [where 1 is for poor and 5 if for the excellent diagnostic quality]. Student's t-test was used to test the significance of difference between the mean image quality score assigned to input and processed images at significance level α = 0.05. Results: The application of IT functions with standardized parameters significantly improved the quality of high dynamic range bone scintigraphic images ( P enhancement. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  18. Underwater image quality enhancement of sea cucumbers based on improved histogram equalization and wavelet transform

    Directory of Open Access Journals (Sweden)

    Xi Qiao

    2017-09-01

    Full Text Available Sea cucumbers usually live in an environment where lighting and visibility are generally not controllable, which cause the underwater image of sea cucumbers to be distorted, blurred, and severely attenuated. Therefore, the valuable information from such an image cannot be fully extracted for further processing. To solve the problems mentioned above and improve the quality of the underwater images of sea cucumbers, pre-processing of a sea cucumber image is attracting increasing interest. This paper presents a new method based on contrast limited adaptive histogram equalization and wavelet transform (CLAHE-WT to enhance the sea cucumber image quality. CLAHE was used to process the underwater image for increasing contrast based on the Rayleigh distribution, and WT was used for de-noising based on a soft threshold. Qualitative analysis indicated that the proposed method exhibited better performance in enhancing the quality and retaining the image details. For quantitative analysis, the test with 120 underwater images showed that for the proposed method, the mean square error (MSE, peak signal to noise ratio (PSNR, and entropy were 49.2098, 13.3909, and 6.6815, respectively. The proposed method outperformed three established methods in enhancing the visual quality of sea cucumber underwater gray image.

  19. Edge enhancement algorithm for low-dose X-ray fluoroscopic imaging.

    Science.gov (United States)

    Lee, Min Seok; Park, Chul Hee; Kang, Moon Gi

    2017-12-01

    Low-dose X-ray fluoroscopy has continually evolved to reduce radiation risk to patients during clinical diagnosis and surgery. However, the reduction in dose exposure causes quality degradation of the acquired images. In general, an X-ray device has a time-average pre-processor to remove the generated quantum noise. However, this pre-processor causes blurring and artifacts within the moving edge regions, and noise remains in the image. During high-pass filtering (HPF) to enhance edge detail, this noise in the image is amplified. In this study, a 2D edge enhancement algorithm comprising region adaptive HPF with the transient improvement (TI) method, as well as artifacts and noise reduction (ANR), was developed for degraded X-ray fluoroscopic images. The proposed method was applied in a static scene pre-processed by a low-dose X-ray fluoroscopy device. First, the sharpness of the X-ray image was improved using region adaptive HPF with the TI method, which facilitates sharpening of edge details without overshoot problems. Then, an ANR filter that uses an edge directional kernel was developed to remove the artifacts and noise that can occur during sharpening, while preserving edge details. The quantitative and qualitative results obtained by applying the developed method to low-dose X-ray fluoroscopic images and visually and numerically comparing the final images with images improved using conventional edge enhancement techniques indicate that the proposed method outperforms existing edge enhancement methods in terms of objective criteria and subjective visual perception of the actual X-ray fluoroscopic image. The developed edge enhancement algorithm performed well when applied to actual low-dose X-ray fluoroscopic images, not only by improving the sharpness, but also by removing artifacts and noise, including overshoot. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Solitary hepatic infantile hemangioendothelioma: dynamic gadolinium-enhanced MR imaging findings

    International Nuclear Information System (INIS)

    Mortele, Koenraad J.; Vanzieleghem, Bart; Mortele, Bart; Benoit, Yves; Ros, Pablo R.

    2002-01-01

    We report the MRI findings of a solitary hepatic infantile hemangioendothelioma (IHE) diagnosed in a 14-day-old girl. To the best of our knowledge, only one report has illustrated the dynamic gadolinium-enhanced MR imaging features of IHE previously. Compounding the rarity of presentation as a solitary mass, the gadolinium-enhanced MRI appearance in our case is unique, because the IHE showed an early rim-like pseudocapsular enhancement followed by progressive fill-in of the lesion on delayed imaging. (orig.)

  1. VISIDEP™: visual image depth enhancement by parallax induction

    Science.gov (United States)

    Jones, Edwin R.; McLaurin, A. P.; Cathey, LeConte

    1984-05-01

    The usual descriptions of depth perception have traditionally required the simultaneous presentation of disparate views presented to separate eyes with the concomitant demand that the resulting binocular parallax be horizontally aligned. Our work suggests that the visual input information is compared in a short-term memory buffer which permits the brain to compute depth as it is normally perceived. However, the mechanism utilized is also capable of receiving and processing the stereographic information even when it is received monocularly or when identical inputs are simultaneously fed to both eyes. We have also found that the restriction to horizontally displaced images is not a necessary requirement and that improvement in image acceptability is achieved by the use of vertical parallax. Use of these ideas permit the presentation of three-dimensional scenes on flat screens in full color without the encumbrance of glasses or other viewing aids.

  2. Morphological image processing for quantitative shape analysis of biomedical structures: effective contrast enhancement

    International Nuclear Information System (INIS)

    Kimori, Yoshitaka

    2013-01-01

    A contrast enhancement approach utilizing a new type of mathematical morphology called rotational morphological processing is introduced. The method is quantitatively evaluated and then applied to some medical images. Image processing methods significantly contribute to visualization of images captured by biomedical modalities (such as mammography, X-ray computed tomography, magnetic resonance imaging, and light and electron microscopy). Quantitative interpretation of the deluge of complicated biomedical images, however, poses many research challenges, one of which is to enhance structural features that are scarcely perceptible to the human eye. This study introduces a contrast enhancement approach based on a new type of mathematical morphology called rotational morphological processing. The proposed method is applied to medical images for the enhancement of structural features. The effectiveness of the method is evaluated quantitatively by the contrast improvement ratio (CIR). The CIR of the proposed method is 12.1, versus 4.7 and 0.1 for two conventional contrast enhancement methods, clearly indicating the high contrasting capability of the method

  3. Mediastinal lymphoma: quantitative changes in gadolinium enhancement at MR imaging after treatment.

    Science.gov (United States)

    Rahmouni, A; Divine, M; Lepage, E; Jazaerli, N; Belhadj, K; Gaulard, P; Golli, M; Reyes, F; Vasile, N

    2001-06-01

    To compare changes in gadolinium enhancement at magnetic resonance (MR) imaging with outcome in mediastinal lymphoma after treatment. Thirty-one patients with bulky mediastinal lymphoma (17 with Hodgkin disease, 14 with non-Hodgkin lymphoma) underwent serial MR imaging before and up to 50 months after treatment, with routine follow-up (including computed tomography). Signal intensity ratios between masses and muscle were calculated on T1-weighted, T2-weighted, and contrast material-enhanced T1-weighted spin-echo MR images. The percentage enhancement and signal intensity ratios of mediastinal masses on T2-weighted MR images were calculated at diagnosis and during and after treatment. Twenty-one patients with persistent complete remission had a mean percentage enhancement of residual masses (4%; range, -26% to 40%) that was significantly lower than that of initial masses (78%; range, 41%-124%). Although the mean signal intensity ratio of residual masses on T2-weighted images was significantly lower than that of initial masses, an increase in this ratio was observed in four patients after treatment. In seven patients with relapse, the percentage enhancement value of the residual mass was as high as that of the initial mass. Gadolinium enhancement of lymphomatous masses of the mediastinum decreased markedly after treatment in patients in continuous complete remission but not in patients with relapse.

  4. The law, economics and politics of international standardisation

    NARCIS (Netherlands)

    Delimatsis, Panagiotis

    2015-01-01

    In an era of increased reliance on private regulatory bodies and globalised economic activity, standardisation is the field where politics, technical expertise and strategic behaviour meet and interact. International standard-setting bodies exemplify the rise of transnational governance and the

  5. Assessment framework for standardisation activities ResiStand

    NARCIS (Netherlands)

    Stolk, D.J.; Lee, M.D.E. van der; Petiet, P.J.; Liedtke, C.; Lindner, R.; Zetten, J. van; Karppinen, A.; Anson, S.; Kroener, I.

    2017-01-01

    Standardisation is a powerful tool to achieve better interoperability. However, it needs to overcome a lack of interest and modest participation from stakeholders. Also, promising research results are not always used as the basis for new standards. The overall goal of ResiStand is to find new ways

  6. Standardisation of Bull's Mental Skills Questionnaire in South Africa ...

    African Journals Online (AJOL)

    The contemporary science of sport and exercise psychology requires the standardisation of mental skills questionnaires to facilitate accurate assessment of and intervention for individuals and groups in various health and sport related contexts. The study presents international research findings regarding the ...

  7. Inequalities in mortality: study rates, not standardised mortality ratios [Letter

    NARCIS (Netherlands)

    Bonneux, L.G.A.

    2010-01-01

    In their study from 1921 to 2007 Thomas and colleagues conclude on the basis of standardised mortality ratios that inequalities in mortality continue to rise and are now almost as high as in the 1930s. Relative ratios are, however, misleading when absolute rates change strongly. I calculated the

  8. Standardised patient-simulated practice learning: A rich ...

    African Journals Online (AJOL)

    This study investigates the use of standardised patients (SPs) in a simulated patient interview as a learning strategy to bridge the theory-practice gap. Simulation helps students to develop skills such as communication, higher cognitive thinking, decision-making and problem-solving. There is evidence to support the use of ...

  9. Lessons from Small-scale Standardised Testing of English Reading ...

    African Journals Online (AJOL)

    The superior performance by the public school can partly be explained by teachers teaching experience, most of them have been teaching for more than ten years and greater community support for the school. It is recommended that data produced through small-scale standardised testing should be used by school ...

  10. X-ray scatter signatures for enhanced breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kidane, Ghirmay; Speller, Robert; Royle, Gary [Medical Physics and Bioengineering Department, University College Landon, 11-20 Capper Street, London WC1E 6JA (United Kingdom)

    1999-12-31

    Conventional mammographic imaging suffers from a low specificity. The main cause is the small difference in the x-ray attenuation properties of healthy and diseased tissue leading to poor contrast in the image. It has been observed that additional information on breast tissue type can be obtained from x-ray diffraction effects. A study of excised normal and neoplastic breast tissue samples using x-ray diffraction apparatus has been observed that significant differences exist in the measured spectra between carcinoma and healthy tissue adjacent to the carcinoma. Such a difference allows tissue type to be characterised according to is diseased state. Furthermore the information can be applied to improve diagnosis. It is proposed that collection and analysis of the scattered x-rays present during a mammographic procedure can supply the additional information and be used to improve the image contrast. The ultimate aim of the project is to improve the specificity of x-ray mammography. (authors) 10 refs., 3 figs.

  11. Gadolinium-DTPA-enhanced magnetic resonance imaging of musculoskeletal infectious processes

    International Nuclear Information System (INIS)

    Hopkins, K.L.; Li, K.C.P.; Bergman, G.

    1995-01-01

    The purpose of this study was to assess whether gadolinium-enhanced magnetic resonance imaging (MRI) provides diagnostic information beyond that given by nonenhanced imaging in the evaluation of musculoskeletal infectious processes and whether it can be used for differentiating infectious from noninfectious inflammatory lesions. Magnetic resonance images performed with and without intravenous gadolinium-DTPA in 34 cases in which musculoskeletal infection had been clinically suspected were reviewed. Infectious lesions-including osteomyelitis, pyarthrosis, abscess, and cellulitis-were confirmed in a total of 22 cases: in 15 by biopsy or drainage and in 7 by clinical course. Our results show that gadolinium-DTPA-enhanced MRI is a highly sensitive technique in diagnosing musculoskeletal infectious lesions. It is especially useful in distinguishing abscesses from surrounding cellulitis/myositis. Lack of contrast enhancement rules out infection with a high degree of certainty. However, contrast enhancement cannot be used to reliably distinguish infectious from noninfectious inflammatory conditions. (orig.)

  12. Gadolinium-DTPA-enhanced magnetic resonance imaging of musculoskeletal infectious processes

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, K.L. [Dept. of Diagnostic Radiology, Stanford Univ. Medical Center, CA (United States); Li, K.C.P. [Dept. of Diagnostic Radiology, Stanford Univ. Medical Center, CA (United States); Bergman, G. [Dept. of Diagnostic Radiology, Stanford Univ. Medical Center, CA (United States)

    1995-07-01

    The purpose of this study was to assess whether gadolinium-enhanced magnetic resonance imaging (MRI) provides diagnostic information beyond that given by nonenhanced imaging in the evaluation of musculoskeletal infectious processes and whether it can be used for differentiating infectious from noninfectious inflammatory lesions. Magnetic resonance images performed with and without intravenous gadolinium-DTPA in 34 cases in which musculoskeletal infection had been clinically suspected were reviewed. Infectious lesions-including osteomyelitis, pyarthrosis, abscess, and cellulitis-were confirmed in a total of 22 cases: in 15 by biopsy or drainage and in 7 by clinical course. Our results show that gadolinium-DTPA-enhanced MRI is a highly sensitive technique in diagnosing musculoskeletal infectious lesions. It is especially useful in distinguishing abscesses from surrounding cellulitis/myositis. Lack of contrast enhancement rules out infection with a high degree of certainty. However, contrast enhancement cannot be used to reliably distinguish infectious from noninfectious inflammatory conditions. (orig.)

  13. Gadolinium-DTPA-enhanced magnetic resonance imaging and functional outcome in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Kitamura, Jun; Shimada, Toshio; Murakami, Yo; Ochiai, Koichi; Inoue, Shin-ichi; Ishibashi, Yutaka; Kinoshita, Yoshihisa; Sano, Kazuya; Murakami, Rinji

    1999-01-01

    This study was designed to test the hypothesis that Gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA)-enhanced magnetic resonance images (MRI) reflect the severity of ischemic injury during the acute and chronic phases of myocardial infarction (MI). Twenty-nine patients with their first acute MI underwent Gd-DTPA-enhanced MRI in the first week (4.2±0.3 days) and at 1 month after onset. Pairs of left ventriculograms were compared with Gd-DTPA-enhanced magnetic resonance images, classified into 3 pattern groups: hyper-enhancement, with and without a central hypo-enhanced region (P1 and P2, respectively), and non-enhancement (P3). In the acute phase of MI, P1 was found in 10, P2 in 11, and P3 in 8 patients. One month later, the image pattern had changed from P1 to P2 in a single patient, from P2 to P3 in 4 patients, and had remained identical in the others. Patients with P3 showed improvement of anterior wall motion in the 1-month follow-up study, and had higher TIMI flow grades and lower peak creatine kinase values than those without recovery. Thus, Gd-DTPA-enhanced magnetic resonance images, closely reflecting the severity of myocardial injury, are useful in predicting myocardial functional recovery after MI. (author)

  14. Detection of hepatic metastasis: Manganese- and ferucarbotran-enhanced MR imaging

    International Nuclear Information System (INIS)

    Choi, Jin-Young; Kim, Myeong-Jin; Kim, Joo Hee; Kim, Seung Hyoung; Ko, Heung-Kyu; Lim, Joon Seok; Oh, Young Taik; Chung, Jae-Joon; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang

    2006-01-01

    Purpose: To compare the mangafodipir trisodium (MnDPDP)-enhanced and ferucarbotran-enhanced magnetic resonance imaging (MRI) for the detection of hepatic metastases. Material and methods: Twenty patients with known hepatic metastasis underwent MR imaging using mangafodipir trisodium and ferucarbotran in at least 1-day intervals. Thirty-eight metastases were confirmed either histologically or clinically. Two radiologists independently reviewed the MnDPDP-enhanced and ferucarbotran-enhanced sets in a random order. The sensitivity and accuracy of lesion detection and the ability to distinguish a benign lesion from a malignant lesion were compared by the areas (Az) under the receiver operating characteristic (ROC) curve. The lesion-liver contrast-to-noise ratios (CNR) were compared by paired t-test. Results: The overall accuracy for detecting metastases was not significantly different between the MnDPDP set (Az = 0.912 and 0.913 for reader 1 and 2, respectively) and the SPIO set (Az = 0.920 and 0.950). The CNR at the MnDPDP-enhanced images and the SPIO-enhanced images were not significantly different (P = 0.146). Conclusion: Both MnDPDP- and ferucarbotran-enhanced MRI have a comparable accuracy in detecting hepatic metastasis

  15. Neonatal chest image quality addressed through training to enhance radiographer awareness

    Directory of Open Access Journals (Sweden)

    Hesta Friedrich-Nel

    2018-03-01

    Full Text Available Background: Diagnostic radiographers working in the neonatal intensive care unit primarily aim to produce an image of optimal quality using optimal exposure techniques without repeating exposures, to keep neonatal radiation dose to a minimum.   Objectives: The aim of the study was to determine whether radiographers were producing optimal quality chest images and, if not, whether additional training could contribute to reaching this goal in the Free State Province of South Africa.   Methods: Neonatal chest image quality was determined in the Neonatal Intensive Care Unit by using a checklist based on and compiled from published guidelines to evaluate the quality of 450 randomly-selected images. Thereafter, a training programme was designed, based on the evaluation criteria of the checklist and image quality areas identified. The training also referred to positioning techniques that should be applied to ensure optimal image quality. After presentation of the training, 450 newly-produced neonatal chest images were evaluated. These images were selected through purposive sampling as this evaluation only included images of participating radiographers who completed the training.   Results: Image quality that showed significant improvement included a reduction in electrocardiogram lines superimposed on chest anatomy, a tendency to centre closer to thoracic vertebra four, and visible four-sided collimation on images. Image quality areas with no significant enhancement were the absence of lead markers and radiation shielding.   Conclusion: The study has shown that a training programme has the potential to improve neonatal chest image quality.

  16. First-pass myocardial perfusion MR imaging with gadolinium-enhanced turbo FLASH

    International Nuclear Information System (INIS)

    Teresi, L.M.; Smith, C.; Messenger, J.; Watanabe, A.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Remer, J.; Rappaport, A.; Bradley, W.G.

    1990-01-01

    This paper determines the efficacy of MR first-pass myocardial perfusion imaging using gadolinium-enhanced Turbo--fast low-angle shot (FLASH) ultrafast imaging combined with MR systolic wall thickening data for the determination of myocardial viability. Five normal volunteers and five patients with remote myocardial infarction were studied on a 1.5-T imaging system (Siemans, Ehrlangen, NJ). Turbo-FLASH imaging utilized a 180 degrees inversion pulse followed by a rapid gradient-echo sequence (TI 400 msec, TE2 msec, TR 4.9 msec, FA 8 degrees) with a complete 64 x 64 matrix image (300 mm FOV) being acquired in 300 msec. First-pass myocardial perfusion imaging was performed in the short-axis and long-axis oblique projections with a concantenated series of Turbo-FLASH images triggered to end-systole acquired immediately before and during a rapid bolus injection of 5cc gadolinium-DTPA

  17. Single underwater image enhancement based on color cast removal and visibility restoration

    Science.gov (United States)

    Li, Chongyi; Guo, Jichang; Wang, Bo; Cong, Runmin; Zhang, Yan; Wang, Jian

    2016-05-01

    Images taken under underwater condition usually have color cast and serious loss of contrast and visibility. Degraded underwater images are inconvenient for observation and analysis. In order to address these problems, an underwater image-enhancement method is proposed. A simple yet effective underwater image color cast removal algorithm is first presented based on the optimization theory. Then, based on the minimum information loss principle and inherent relationship of medium transmission maps of three color channels in an underwater image, an effective visibility restoration algorithm is proposed to recover visibility, contrast, and natural appearance of degraded underwater images. To evaluate the performance of the proposed method, qualitative comparison, quantitative comparison, and color accuracy test are conducted. Experimental results demonstrate that the proposed method can effectively remove color cast, improve contrast and visibility, and recover natural appearance of degraded underwater images. Additionally, the proposed method is comparable to and even better than several state-of-the-art methods.

  18. Diagnostic Accuracy of Dynamic Contrast Enhanced Magnetic Resonance Imaging in Characterizing Lung Masses

    Science.gov (United States)

    Inan, Nagihan; Arslan, Arzu; Donmez, Muhammed; Sarisoy, Hasan Tahsin

    2016-01-01

    Background Imaging plays a critical role not only in the detection, but also in the characterization of lung masses as benign or malignant. Objectives To determine the diagnostic accuracy of dynamic magnetic resonance imaging (MRI) in the differential diagnosis of benign and malignant lung masses. Patients and Methods Ninety-four masses were included in this prospective study. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, followed by a T1-weighted FFE sequence in the late phase (5th minutes). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained and the maximum relative enhancement, wash-in rate, and time-to-peak enhancement of masses in both groups were calculated. Results The early phase contrast enhancement patterns were homogeneous in 78.2% of the benign masses, while heterogeneous in 74.4% of the malignant tumors. On the late phase images, 70.8% of the benign masses showed homogeneous enhancement, while most of the malignant masses showed heterogeneous enhancement (82.4%). During the first pass, the maximum relative enhancement and wash-in rate values of malignant masses were significantly higher than those of the benign masses (P = 0.03 and 0.04, respectively). The cutoff value at 15% yielded a sensitivity of 85.4%, specificity of 61.2%, and positive predictive value of 68.7% for the maximum relative enhancement. Conclusion Contrast enhancement patterns and SI-time curve analysis of MRI are helpful in the differential diagnosis of benign and malignant lung masses. PMID:27703654

  19. Edge enhancement and noise suppression for infrared image based on feature analysis

    Science.gov (United States)

    Jiang, Meng

    2018-06-01

    Infrared images are often suffering from background noise, blurred edges, few details and low signal-to-noise ratios. To improve infrared image quality, it is essential to suppress noise and enhance edges simultaneously. To realize it in this paper, we propose a novel algorithm based on feature analysis in shearlet domain. Firstly, as one of multi-scale geometric analysis (MGA), we introduce the theory and superiority of shearlet transform. Secondly, after analyzing the defects of traditional thresholding technique to suppress noise, we propose a novel feature extraction distinguishing image structures from noise well and use it to improve the traditional thresholding technique. Thirdly, with computing the correlations between neighboring shearlet coefficients, the feature attribute maps identifying the weak detail and strong edges are completed to improve the generalized unsharped masking (GUM). At last, experiment results with infrared images captured in different scenes demonstrate that the proposed algorithm suppresses noise efficiently and enhances image edges adaptively.

  20. Proton nuclear magnetic resonance imaging of regionally ischemic canine hearts: effects of paramagnetic proton signal enhancement

    International Nuclear Information System (INIS)

    Brady, T.J.; Goldman, M.R.; Pykett, I.L.; Buonanno, F.S.; Kistler, J.P.; Newhouse, J.H.; Burt, C.T.; Hinshaw, W.S.; Pohost, G.M.

    1982-01-01

    In a study to evaluate the potential of proton nuclear magnetic resonance (NMR) imaging with and without manganese contrast enhancement for detecting acute myocardial infarction, 12 dogs underwent 90-minute occlusion of the left circumflex coronary artery. Transverse-section NMR images of the excised, nonbeating heart were obtained at 1-cm intervals using the steady-state-free-precession (SSFP) technique. All NMR images revealed detailed structure of the heart. The three hearts without manganese showed no difference in intensity between the normal and the ischemic posterior regions, whereas those with manganese demonstrated a clearly demarcated zone of reduced signal intensity consistent with the ischemic zone. It is concluded that high-resolution tomograms of the excised canine myocardium can be obtained using proton NMR imaging. With the SSFP imaging technique, proton signal enhancement with manganese infusion is necessary to differentiate between ischemic and nonischemic myocardium after 90 minutes of coronary occlusion

  1. Efficient image enhancement using sparse source separation in the Retinex theory

    Science.gov (United States)

    Yoon, Jongsu; Choi, Jangwon; Choe, Yoonsik

    2017-11-01

    Color constancy is the feature of the human vision system (HVS) that ensures the relative constancy of the perceived color of objects under varying illumination conditions. The Retinex theory of machine vision systems is based on the HVS. Among Retinex algorithms, the physics-based algorithms are efficient; however, they generally do not satisfy the local characteristics of the original Retinex theory because they eliminate global illumination from their optimization. We apply the sparse source separation technique to the Retinex theory to present a physics-based algorithm that satisfies the locality characteristic of the original Retinex theory. Previous Retinex algorithms have limited use in image enhancement because the total variation Retinex results in an overly enhanced image and the sparse source separation Retinex cannot completely restore the original image. In contrast, our proposed method preserves the image edge and can very nearly replicate the original image without any special operation.

  2. Efficient Hardware Implementation For Fingerprint Image Enhancement Using Anisotropic Gaussian Filter.

    Science.gov (United States)

    Khan, Tariq Mahmood; Bailey, Donald G; Khan, Mohammad A U; Kong, Yinan

    2017-05-01

    A real-time image filtering technique is proposed which could result in faster implementation for fingerprint image enhancement. One major hurdle associated with fingerprint filtering techniques is the expensive nature of their hardware implementations. To circumvent this, a modified anisotropic Gaussian filter is efficiently adopted in hardware by decomposing the filter into two orthogonal Gaussians and an oriented line Gaussian. An architecture is developed for dynamically controlling the orientation of the line Gaussian filter. To further improve the performance of the filter, the input image is homogenized by a local image normalization. In the proposed structure, for a middle-range reconfigurable FPGA, both parallel compute-intensive and real-time demands were achieved. We manage to efficiently speed up the image-processing time and improve the resource utilization of the FPGA. Test results show an improved speed for its hardware architecture while maintaining reasonable enhancement benchmarks.

  3. An enhanced narrow-band imaging method for the microvessel detection

    Science.gov (United States)

    Yu, Feng; Song, Enmin; Liu, Hong; Wan, Youming; Zhu, Jun; Hung, Chih-Cheng

    2018-02-01

    A medical endoscope system combined with the narrow-band imaging (NBI), has been shown to be a superior diagnostic tool for early cancer detection. The NBI can reveal the morphologic changes of microvessels in the superficial cancer. In order to improve the conspicuousness of microvessel texture, we propose an enhanced NBI method to improve the conspicuousness of endoscopic images. To obtain the more conspicuous narrow-band images, we use the edge operator to extract the edge information of the narrow-band blue and green images, and give a weight to the extracted edges. Then, the weighted edges are fused with the narrow-band blue and green images. Finally, the displayed endoscopic images are reconstructed with the enhanced narrow-band images. In addition, we evaluate the performance of enhanced narrow-band images with different edge operators. Experimental results indicate that the Sobel and Canny operators achieve the best performance of all. Compared with traditional NBI method of Olympus company, our proposed method has more conspicuous texture of microvessel.

  4. Chain of evidence generation for contrast enhancement in digital image forensics

    Science.gov (United States)

    Battiato, Sebastiano; Messina, Giuseppe; Strano, Daniela

    2010-01-01

    The quality of the images obtained by digital cameras has improved a lot since digital cameras early days. Unfortunately, it is not unusual in image forensics to find wrongly exposed pictures. This is mainly due to obsolete techniques or old technologies, but also due to backlight conditions. To extrapolate some invisible details a stretching of the image contrast is obviously required. The forensics rules to produce evidences require a complete documentation of the processing steps, enabling the replication of the entire process. The automation of enhancement techniques is thus quite difficult and needs to be carefully documented. This work presents an automatic procedure to find contrast enhancement settings, allowing both image correction and automatic scripting generation. The technique is based on a preprocessing step which extracts the features of the image and selects correction parameters. The parameters are thus saved through a JavaScript code that is used in the second step of the approach to correct the image. The generated script is Adobe Photoshop compliant (which is largely used in image forensics analysis) thus permitting the replication of the enhancement steps. Experiments on a dataset of images are also reported showing the effectiveness of the proposed methodology.

  5. Use of synchrotron-based diffraction-enhanced imaging for visualization of soft tissues in invertebrates

    International Nuclear Information System (INIS)

    Rao, Donepudi V.; Swapna, Medasani; Cesareo, Roberto; Brunetti, Antonio; Zhong, Zhong; Akatsuka, Takao; Yuasa, Tetsuya; Takeda, Tohoru; Gigante, Giovanni E.

    2010-01-01

    Images of terrestrial and marine invertebrates (snails and bivalves) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging. Synchrotron X-rays of 20, 30 and 40 keV were used, which penetrate deep enough into animal soft tissues. The phase of X-ray photons shifts slightly as they traverse an object, such as animal soft tissue, and interact with its atoms. Biological features, such as shell morphology and animal physiology, have been visualized. The contrast of the images obtained at 40 keV is the best. This optimum energy provided a clear view of the internal structural organization of the soft tissue with better contrast. The contrast is higher at edges of internal soft-tissue structures. The image improvements achieved with the diffraction-enhanced imaging technique are due to extinction, i.e., elimination of ultra-small-angle scattering. They enabled us to identify a few embedded internal shell features, such as the origin of the apex, which is the firmly attached region of the soft tissue connecting the umbilicus to the external morphology. Diffraction-enhanced imaging can provide high-quality images of soft tissues valuable for biology.

  6. Use of synchrotron-based diffraction-enhanced imaging for visualization of soft tissues in invertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Donepudi V., E-mail: donepudi_venkateswararao@rediffmail.co [Istituto di Matematica e Fisica, Universita degli Studi di Sassari, Via Vienna 2, 07100 Sassari (Italy); Swapna, Medasani, E-mail: medasanisw@gmail.co [Istituto di Matematica e Fisica, Universita degli Studi di Sassari, Via Vienna 2, 07100 Sassari (Italy); Cesareo, Roberto; Brunetti, Antonio [Istituto di Matematica e Fisica, Universita degli Studi di Sassari, Via Vienna 2, 07100 Sassari (Italy); Zhong, Zhong [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States); Akatsuka, Takao; Yuasa, Tetsuya [Department of Bio-System Engineering, Faculty of Engineering, Yamagata University, Yonezawa-shi, Yamagata-992-8510 (Japan); Takeda, Tohoru [Allied Health Science, Kitasato University 1-15-1 Kitasato, Sagamihara, Kanagawa 228-8555 (Japan); Gigante, Giovanni E. [Dipartimento di Fisica, Universita di Roma, La Sapienza, 00185 Roma (Italy)

    2010-09-15

    Images of terrestrial and marine invertebrates (snails and bivalves) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging. Synchrotron X-rays of 20, 30 and 40 keV were used, which penetrate deep enough into animal soft tissues. The phase of X-ray photons shifts slightly as they traverse an object, such as animal soft tissue, and interact with its atoms. Biological features, such as shell morphology and animal physiology, have been visualized. The contrast of the images obtained at 40 keV is the best. This optimum energy provided a clear view of the internal structural organization of the soft tissue with better contrast. The contrast is higher at edges of internal soft-tissue structures. The image improvements achieved with the diffraction-enhanced imaging technique are due to extinction, i.e., elimination of ultra-small-angle scattering. They enabled us to identify a few embedded internal shell features, such as the origin of the apex, which is the firmly attached region of the soft tissue connecting the umbilicus to the external morphology. Diffraction-enhanced imaging can provide high-quality images of soft tissues valuable for biology.

  7. Efficiency enhancements for MCP-based beta autoradiography imaging

    CERN Document Server

    Lees, J E

    2002-01-01

    We describe three approaches to increase the beta detection efficiency of microchannel plate detectors for biological beta autoradiography:(a)reversing the microchannel plate (MCP) bias polarity, changing the conventional high negative voltage on the input MCP to a grounded input, (b) a reduction in MCP pore size from 12.5 to 6 mu m, (c) using a CsI coating as an efficient secondary electron emitter. We also present our first measurements of double-tracer ( sup 3 H and sup 1 sup 4 C) imaging using pulse height analysis to distinguish between isotopes.

  8. Magnetic resonance imaging of the pituitary adenoma: Analysis of the enhancement patterns

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ik; Choi, Woo Suk; Shin, In Soo; Ryu, Kyung Nam; Yoon, Yup [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1993-11-15

    The magnetic resonance images (MRI) of 30 patients with surgically or biochemically confirmed pituitary adenomas (20 macroadenomas, 10 microadenomas) were retrospectively evaluated. Ten patients had hyperprolactinaemia, another eight had acromegaly, another eight had nonfunctioning adenoma and four had cushing disease. The examinations were performed at a1.5 T superconducting MR system using a multisection spin-echo technique with 3 mm thick sections and a 256 X 224 matrix. TI weighted sagittal and coronal images were obtained before and within 30 minutes after the administration of Gd-DTPA (0.1 mmol/kg). Analysis of the MRI was focused on the signal intensity and enhancement patterns of the pituitary adenoma before and after Gd-DTPA administration. Compared with endocrinological diagnosis, macroadenoma showed heterogeneous enhancement in 55%, rim enhancement in 35% and homogeneous enhancement in 10%. Conclusively, the enhancement patterns of the pituitary adenoma did not correlate with the subtypes made according to hormone production.

  9. Geological mapping potential of computer-enhanced images from the Shuttle Imaging Radar - Lisbon Valley Anticline, Utah

    Science.gov (United States)

    Curlis, J. D.; Frost, V. S.; Dellwig, L. F.

    1986-01-01

    Computer-enhancement techniques applied to the SIR-A data from the Lisbon Valley area in the northern portion of the Paradox basin increased the value of the imagery in the development of geologically useful maps. The enhancement techniques include filtering to remove image speckle from the SIR-A data and combining these data with Landsat multispectral scanner data. A method well-suited for the combination of the data sets utilized a three-dimensional domain defined by intensity-hue-saturation (IHS) coordinates. Such a system allows the Landsat data to modulate image intensity, while the SIR-A data control image hue and saturation. Whereas the addition of Landsat data to the SIR-A image by means of a pixel-by-pixel ratio accentuated textural variations within the image, the addition of color to the combined images enabled isolation of areas in which gray-tone contrast was minimal. This isolation resulted in a more precise definition of stratigraphic units.

  10. Efficacy of gadolinium enhanced MR imaging for the diagnosis of Legg-Calve-Perthes disease

    International Nuclear Information System (INIS)

    Kim, Jee Eun; Kim, Hyung Sik; Kim, Ji Hye

    2008-01-01

    The purpose of this study was to evaluate the efficacy of gadolinium enhanced MR imaging for making the diagnosis of Legg-Calve-Perthes (LCP) disease. We studied the gadolinium enhanced MR images of 14 hips in 12 children who had the diagnosis of LCP disease. We retrospectively analyzed the extent of necrosis, the epiphyseal revascularization pathways and the metaphyseal changes. The absence of enhancement on gadolinium enhanced MRI was noted in all cases of LCP disease. Diffuse absence of enhancement was observed in 9 femoral epiphyses. Two of them showed normal bone marrow signal intensity on the T1 and T1-weighted images. Focal absence of enhancement was observed in 5 femoral epiphyses. Enhanced MRI showed better epiphyseal revascularization in the lateral column (five cases), in the lateral and medial columns (four cases) and in the transphyseal pathway (three cases). Metaphyseal change was observed in two cases. Gadolinium enhanced MRI allows detection of LCP disease and an accurate analysis of the different revascularization patterns, and this helpful for predicting the prognosis

  11. MR of normal pancreas : comparison of five pulse sequences and enhancing patterns on dynamic imaging

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Kim, Tae Kyoung; Hong, Sung Hwan; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To compare T1-weighted FLASH and turbo spin echo (SE) T2-weighted sequences with conventional T1- and T2-weighted sequences in imaging normal pancreas and to describe the enhancing patterns on dynamic MR imging. Forty-four patients with presumed hepatic hemangiomas were studied at 1.0T or 1.5T by using conventional SE sequences (T1-weighted, T2-weighted, and heavily T2-weighted), turbo-SE T2-weighted sequences, and breath-hold T1-weighted FLASH sequences acquired before, immediately on, and at 1, 2, 3, and 5 or 10 minutes after injection of a bolus of gadopentetate dimeglumine. No patients had either a history or its clinical features of pancreatic disease. Images were quantitatively analyzed for signal-difference-to noise ratios (SD/Ns) between the pancreas and peripancreatic fat. Percentage enhancement of the pancreas was measured on each dynamic MR image. Conspicuity of the pancreatic border was qualitatively evaluated according to a consensus, reached by three radiologists. Turbo-SE T2-weighted images had a significantly higher SD/N ratio (p<0.001) and better conspicuity of the pancreatic border (p<0.001) than SE T2- and heavily T2-weighted images;T1-weighted SE images had a significantly higher SD/N ratio than T1-weighted FLASH images (p<0.001), but there was no significant difference between tham in qualitative analysis (p=0.346). Percentage enhancement immediately on and at 1, 2, 3, 5, and 10 minutes after administration of contrast material was 39.9%, 44.5%, 42.9%, 40.8%, 36.3%, 29.9%, respectively, with peak enhancement at 1 minute. In MR imaging of normal pancreas, turbo-SE T2-weighted imaging is superior to SE T2- and heavily T2- weighted imaging, and SE T1-weighted imaging is superior to T1-weighted FLASH imaging. On serial gadolinium-enhanced FLASH imaging, normal pancreas shows peak enhancement at 1 minute

  12. Gadoxetate disodium-enhanced MR imaging: Differentiation between early-enhancing non-tumorous lesions and hypervascular hepatocellular carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi, E-mail: gossy@par.odn.ne.jp [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1193 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1193 (Japan); Department of Radiology Services, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1193 (Japan); Watanabe, Haruo; Kondo, Hiroshi; Mizuno, Nozomi; Kawada, Hiroshi [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1193 (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan); Bae, Kyongtae T. [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2011-08-15

    Purpose: To retrospectively assess imaging features that help differentiate early-enhancing non-tumorous (EN) hepatic lesions from hepatocellular carcinomas (HCCs) on gadoxetate disodium-enhanced MR imaging. Materials and methods: Our institutional review board approved this retrospective study. We reviewed the studies of 158 patients (92 men and 65 women; age range: 29-91; mean age: 65.6 years) with chronic liver damage, who underwent gadoxetate disodium-enhanced MR imaging at 3T MR scanner. Hypervascular lesions identified during the hepatic artery phase were selected for a study cohort. The location, shape, size (maximum diameter and maximum area), and contrast enhancement signal intensity characteristics of the lesions were evaluated, then compared between the EN and HCC lesions. Results: A total of 65 EN lesions (range: 3-60 mm, mean: 13.6 {+-} 10.6 mm) from 35 patients and 33 HCCs (range: 9-61 mm, mean: 19.3 {+-} 12.6 mm) from 20 patients were identified. Lesions were more frequently round or oval in shape for HCCs (n = 29; 88%) than ENs (n = 26; 40%) (P < 0.01). Unexpectedly, some ENs (n = 12; 18%) showed hypointensity on hepatocyte-phase, and 6 (50%) of them were T2 hyperintense. For lesions smaller than 2 cm (9 ENs and 21 HCCs) on hepatic arterial-phase images, the mean area of hypointensity in hepatocyte-phase (54.2 {+-} 33.1 mm{sup 2}) was significantly smaller than those of the corresponding hyperintensity in hepatic arterial-phase (97.1 {+-} 42.0 mm{sup 2}) for EN lesions (P = 0.019), whereas no significant difference in area was found for HCCs. Conclusion: EN lesions may occasionally present with hypointensity during the hepatocyte-phase; presenting a diagnostic dilemma. In this situation, EN lesions may be differentiated from HCCs when a hypointense area in hepatocyte-phase is smaller than the corresponding hypervascular area in hepatic-arterial phase.

  13. Local contrast-enhanced MR images via high dynamic range processing.

    Science.gov (United States)

    Chandra, Shekhar S; Engstrom, Craig; Fripp, Jurgen; Neubert, Ales; Jin, Jin; Walker, Duncan; Salvado, Olivier; Ho, Charles; Crozier, Stuart

    2018-09-01

    To develop a local contrast-enhancing and feature-preserving high dynamic range (HDR) image processing algorithm for multichannel and multisequence MR images of multiple body regions and tissues, and to evaluate its performance for structure visualization, bias field (correction) mitigation, and automated tissue segmentation. A multiscale-shape and detail-enhancement HDR-MRI algorithm is applied to data sets of multichannel and multisequence MR images of the brain, knee, breast, and hip. In multisequence 3T hip images, agreement between automatic cartilage segmentations and corresponding synthesized HDR-MRI series were computed for mean voxel overlap established from manual segmentations for a series of cases. Qualitative comparisons between the developed HDR-MRI and standard synthesis methods were performed on multichannel 7T brain and knee data, and multisequence 3T breast and knee data. The synthesized HDR-MRI series provided excellent enhancement of fine-scale structure from multiple scales and contrasts, while substantially reducing bias field effects in 7T brain gradient echo, T 1 and T 2 breast images and 7T knee multichannel images. Evaluation of the HDR-MRI approach on 3T hip multisequence images showed superior outcomes for automatic cartilage segmentations with respect to manual segmentation, particularly around regions with hyperintense synovial fluid, across a set of 3D sequences. The successful combination of multichannel/sequence MR images into a single-fused HDR-MR image format provided consolidated visualization of tissues within 1 omnibus image, enhanced definition of thin, complex anatomical structures in the presence of variable or hyperintense signals, and improved tissue (cartilage) segmentation outcomes. © 2018 International Society for Magnetic Resonance in Medicine.

  14. Color image enhancement of medical images using alpha-rooting and zonal alpha-rooting methods on 2D QDFT

    Science.gov (United States)

    Grigoryan, Artyom M.; John, Aparna; Agaian, Sos S.

    2017-03-01

    2-D quaternion discrete Fourier transform (2-D QDFT) is the Fourier transform applied to color images when the color images are considered in the quaternion space. The quaternion numbers are four dimensional hyper-complex numbers. Quaternion representation of color image allows us to see the color of the image as a single unit. In quaternion approach of color image enhancement, each color is seen as a vector. This permits us to see the merging effect of the color due to the combination of the primary colors. The color images are used to be processed by applying the respective algorithm onto each channels separately, and then, composing the color image from the processed channels. In this article, the alpha-rooting and zonal alpha-rooting methods are used with the 2-D QDFT. In the alpha-rooting method, the alpha-root of the transformed frequency values of the 2-D QDFT are determined before taking the inverse transform. In the zonal alpha-rooting method, the frequency spectrum of the 2-D QDFT is divided by different zones and the alpha-rooting is applied with different alpha values for different zones. The optimization of the choice of alpha values is done with the genetic algorithm. The visual perception of 3-D medical images is increased by changing the reference gray line.

  15. Radar image enhancement and simulation as an aid to interpretation and training

    Science.gov (United States)

    Frost, V. S.; Stiles, J. A.; Holtzman, J. C.; Dellwig, L. F.; Held, D. N.

    1980-01-01

    Greatly increased activity in the field of radar image applications in the coming years demands that techniques of radar image analysis, enhancement, and simulation be developed now. Since the statistical nature of radar imagery differs from that of photographic imagery, one finds that the required digital image processing algorithms (e.g., for improved viewing and feature extraction) differ from those currently existing. This paper addresses these problems and discusses work at the Remote Sensing Laboratory in image simulation and processing, especially for systems comparable to the formerly operational SEASAT synthetic aperture radar.

  16. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    International Nuclear Information System (INIS)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco

    2012-01-01

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  17. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland); Laboratory for Micro and Nanotechnology, Paul Scherrer Institut, 5232 Villigen (Switzerland); Philips Technologie GmbH, Roentgenstrasse 24, 22335 Hamburg (Germany); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Radiology, Kantonsspital Baden, 5404 Baden (Switzerland); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Gynecology and Obstetrics, Interdisciplinary Breast Center Baden, Kantonsspital Baden, 5404 Baden (Switzerland); Swiss Light Source, Paul Scherrer Institut, 5232 Villigen, Switzerland and Institute for Biomedical Engineering, University and ETH Zuerich, 8092 Zuerich (Switzerland)

    2012-07-31

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  18. A Fast Enhanced Secure Image Chaotic Cryptosystem Based on Hybrid Chaotic Magic Transform

    Directory of Open Access Journals (Sweden)

    Srinivas Koppu

    2017-01-01

    Full Text Available An enhanced secure image chaotic cryptosystem has been proposed based on hybrid CMT-Lanczos algorithm. We have achieved fast encryption and decryption along with privacy of images. The pseudorandom generator has been used along with Lanczos algorithm to generate root characteristics and eigenvectors. Using hybrid CMT image, pixels are shuffled to accomplish excellent randomness. Compared with existing methods, the proposed method had more robustness to various attacks: brute-force attack, known cipher plaintext, chosen-plaintext, security key space, key sensitivity, correlation analysis and information entropy, and differential attacks. Simulation results show that the proposed methods give better result in protecting images with low-time complexity.

  19. Repeatability and response to therapy of dynamic contrast-enhanced magnetic resonance imaging biomarkers in rheumatoid arthritis in a large multicentre trial setting

    Energy Technology Data Exchange (ETDEWEB)

    Waterton, John C. [University of Manchester, Stopford Building, Manchester Academic Health Sciences Centre, Manchester (United Kingdom); Personalised Healthcare and Biomarkers, AstraZeneca, Macclesfield (United Kingdom); Ho, Meilien [AstraZeneca, Global Medicines Development, Macclesfield (United Kingdom); Nordenmark, Lars H. [AstraZeneca, Global Medicines Development, Moelndal (Sweden); Jenkins, Martin [AstraZeneca, Global Medicines Development, Cambridge (United Kingdom); DiCarlo, Julie; Peterfy, Charles [Spire Sciences Inc, Boca Raton, FL (United States); Guillard, Gwenael; Bowes, Michael A. [Imorphics, Manchester (United Kingdom); Roberts, Caleb; Buonaccorsi, Giovanni [Bioxydyn, Manchester (United Kingdom); Parker, Geoffrey J.M. [University of Manchester, Stopford Building, Manchester Academic Health Sciences Centre, Manchester (United Kingdom); Bioxydyn, Manchester (United Kingdom); Kellner, Herbert [Private Practice and Division of Rheumatology KHI Neuwittelsbach, Muenchen (Germany); Taylor, Peter C. [University of Oxford, Kennedy Institute, Oxford (United Kingdom)

    2017-09-15

    To determine the repeatability and response to therapy of dynamic contrast-enhanced (DCE) MRI biomarkers of synovitis in the hand and wrist of rheumatoid arthritis (RA) patients, and in particular the performance of the transfer constant K{sup trans}, in a multicentre trial setting. DCE-MRI and RA MRI scoring (RAMRIS) were performed with meticulous standardisation at baseline and 6 and 24 weeks in a substudy of fostamatinib monotherapy in reducing synovitis compared with placebo or adalimumab. Analysis employed statistical shape modelling to avoid biased regions-of-interest, kinetic modelling and heuristic analyses. Repeatability was also evaluated. At early study termination, DCE-MRI data had been acquired from 58 patients in 19 imaging centres. K{sup trans} intra-subject coefficient of variation (N = 14) was 30%. K{sup trans} change demonstrated inferiority of fostamatinib (N = 11) relative to adalimumab (N = 10) after 6 weeks (treatment ratio = 1.92, p = 0.003), and failed to distinguish fostamatinib from placebo (N = 10, p = 0.79). RAMRIS showed superiority of fostamatinib relative to placebo at 6 weeks (p = 0.023), and did not distinguish fostamatinib from adalimumab at either 6 (p = 0.175) or 24 (p = 0.230) weeks. This demonstrated repeatability of K{sup trans} and its ability to distinguish treatment groups show that DCE-MRI biomarkers are suitable for use in multicentre RA trials. (orig.)

  20. Chronological evaluation of liver enhancement in patients with chronic liver disease at Gd-EOB-DTPA-enhanced 3-T MR imaging. Does liver function correlate with enhancement?

    International Nuclear Information System (INIS)

    Nakamura, Shinichi; Utsunomiya, Daisuke; Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Nakaura, Takeshi; Morita, Kosuke

    2012-01-01

    The purpose of this study was to investigate the chronological relationship between scan delay and liver enhancement for the hepatobiliary phase on Gd-EOB-DTPA-enhanced MRI and evaluate the effects of liver function on liver enhancement. Hepatobiliary-phase images were retrospectively evaluated in 125 patients with chronic liver disease. Hepatobiliary phase images were obtained at 5, 10, 15, and 20 min after injection. We calculated relative liver enhancement (RLE) at t min after injection by dividing the signal intensity (SI) of the liver at t min by precontrast SI. We compared RLE values at 5, 10, 15, and 20 min and evaluated the detectability of focal hepatic lesions. We analyzed the effect of liver function on RLE with the generalized linear model. There was not significant difference in RLE and lesion detectability at 15 and 20 min. RLE in the Child-Pugh C group was significantly lower than in the Child-Pugh A and B groups. The serum albumin level and prothrombin time were significantly correlated with the liver enhancement. A delay time of 15 min for the hepatobiliary phase was thought to be adequate in patients with mild liver dysfunction. The serum albumin level and prothrombin time would be predictive of liver enhancement in the hepatobiliary phase. (author)

  1. Differentiation of toxoplasmosis and lymphoma in HIV-positive patients with gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Eisenberg, A.D.; Mani, J.R.; Norman, D.

    1990-01-01

    This paper determines whether gadolinium-enhanced MR imaging can be used to differentiate toxoplasmosis and lymphoma in patients with acquired immunodeficiency syndrome. One hundred fifty-nine lesions from 71 MR examinations of eight patients with lymphoma were evaluated for size, location, enhancement characteristics, lesion multiplicity. Multiple lesions occurred in 72% of toxoplasmosis and 75% of lymphoma cases. Toxoplasmosis lesions are smaller, with lesion most commonly between 1 and 2 cm, whereas lymphoma is most often between 2 and 3 cm. Except for a propensity for lymphoma to occur in the temporal lobes, no difference in lesion location was found. Both conditions usually markedly enhance, but the pattern of enhancement differs

  2. Froth Image Acquisition and Enhancement on Optical Correction and Retinex Compensation

    Directory of Open Access Journals (Sweden)

    Weixing Wang

    2018-03-01

    Full Text Available To well monitor and optimize the flotation production, a computer vision and image analysis system is used. In such a system, the first important step is to acquire the froth surface images in high quality. Froth imaging quality is hard to control, and the industrial field noise, froth 3D properties, complex textures, and mixed colors can also cause the flotation image to be difficult to segment and process. To acquire high quality images, a new system for image acquisition of the lead flotation is studied. The system constructs the free-form surface lens based on the non-imaging optics theory, which can improve the optical efficiency of the lens and the uniformity of light sources, and can reduce flare effects. For the compensation, an improved MSR (Multi-Scale Retinex adaptive image algorithm is proposed to increase the brightness and intensity contrast for small bubbles, and to enhance texture details and froth weak edges by analyzing the Retinex output characteristics of the shaded area and improving the gain function. Under the condition of the optimal parameters, the image acquisition system can obtain uniform illumination and reduce different noises. Experiments show that the new froth image acquisition system increases Signal/Noise by 14%, contrast by 21%, and image segmentation accuracy by 26% in an image.

  3. Detail-enhanced multimodality medical image fusion based on gradient minimization smoothing filter and shearing filter.

    Science.gov (United States)

    Liu, Xingbin; Mei, Wenbo; Du, Huiqian

    2018-02-13

    In this paper, a detail-enhanced multimodality medical image fusion algorithm is proposed by using proposed multi-scale joint decomposition framework (MJDF) and shearing filter (SF). The MJDF constructed with gradient minimization smoothing filter (GMSF) and Gaussian low-pass filter (GLF) is used to decompose source images into low-pass layers, edge layers, and detail layers at multiple scales. In order to highlight the detail information in the fused image, the edge layer and the detail layer in each scale are weighted combined into a detail-enhanced layer. As directional filter is effective in capturing salient information, so SF is applied to the detail-enhanced layer to extract geometrical features and obtain directional coefficients. Visual saliency map-based fusion rule is designed for fusing low-pass layers, and the sum of standard deviation is used as activity level measurement for directional coefficients fusion. The final fusion result is obtained by synthesizing the fused low-pass layers and directional coefficients. Experimental results show that the proposed method with shift-invariance, directional selectivity, and detail-enhanced property is efficient in preserving and enhancing detail information of multimodality medical images. Graphical abstract The detailed implementation of the proposed medical image fusion algorithm.

  4. Gadobenate-dimeglumine-enhanced magnetic resonance imaging for hepatic lesions in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Mann, Erika [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto (Canada); Kamath, Binita M. [The Hospital for Sick Children and University of Toronto, Division of Gastroenterology, Hepatology and Nutrition, Toronto (Canada); Babyn, Paul S. [Royal University Hospital, Department of Medical Imaging, Saskatoon (Canada)

    2014-10-15

    Magnetic resonance imaging enhanced by hepatocyte-specific contrast media has been found useful to characterize liver lesions in adults and children. To present our experience with gadobenate dimeglumine (Gd-BOPTA)-enhanced MRI for evaluation of focal liver lesions in children. We retrospectively reviewed gadobenate-dimeglumine-enhanced MR images obtained for evaluation of suspected hepatic lesions in 30 children. Signal characteristics on various sequences including 45- to 60-min hepatobiliary phase images were noted by two radiologists. Chart review identified relevant clinical details including history of cancer treatment, available pathology and stability of lesion size on follow-up imaging. Of the 30 children who had gadobenate-enhanced MRI, 26 showed focal lesions. Diagnoses in 26 children were focal nodular hyperplasia (FNH) in 15, hemangiomas in 3, regenerating nodules in 3, focal fatty infiltration in 2, indeterminate lesions in 3, and one patient each with adenomas, hepatoblastoma and metastasis. Two patients had multiple diagnoses. All FNH lesions (39), all regenerative nodules (19) and an indeterminate lesion were iso- or hyperintense on hepatobiliary-phase images while all other lesions (28) were hypointense to hepatic parenchyma. The average follow-up period was 21.7 months. Our experience with gadobenate-enhanced MRI indicates potential utility of gadobenate in the evaluation of pediatric hepatic lesions in differentiating FNH and regenerating nodules from other lesions. (orig.)

  5. Differential evolution optimization combined with chaotic sequences for image contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Santos Coelho, Leandro dos [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: leandro.coelho@pucpr.br; Sauer, Joao Guilherme [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: joao.sauer@gmail.com; Rudek, Marcelo [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: marcelo.rudek@pucpr.br

    2009-10-15

    Evolutionary Algorithms (EAs) are stochastic and robust meta-heuristics of evolutionary computation field useful to solve optimization problems in image processing applications. Recently, as special mechanism to avoid being trapped in local minimum, the ergodicity property of chaotic sequences has been used in various designs of EAs. Three differential evolution approaches based on chaotic sequences using logistic equation for image enhancement process are proposed in this paper. Differential evolution is a simple yet powerful evolutionary optimization algorithm that has been successfully used in solving continuous problems. The proposed chaotic differential evolution schemes have fast convergence rate but also maintain the diversity of the population so as to escape from local optima. In this paper, the image contrast enhancement is approached as a constrained nonlinear optimization problem. The objective of the proposed chaotic differential evolution schemes is to maximize the fitness criterion in order to enhance the contrast and detail in the image by adapting the parameters using a contrast enhancement technique. The proposed chaotic differential evolution schemes are compared with classical differential evolution to two testing images. Simulation results on three images show that the application of chaotic sequences instead of random sequences is a possible strategy to improve the performance of classical differential evolution optimization algorithm.

  6. Enhancement of intracranial meningeal lesions with Gd-DTPA MR imaging

    International Nuclear Information System (INIS)

    Brown, E.; De La Paz, R.

    1989-01-01

    Pathologic intracranial meningeal enhancement on Gd-DTPA MR images (T1-weighted spin-echo sequence, 800/20 [repetition time msec/echo time msec] 1.5 T) was evaluated in 23 patients. Diagnoses included metastatic neoplasm (13 cases), benign neoplasm (four), infection (one), subarachnoid hemorrhage (three), and subdural hematoma (two). Eleven patients had undergone previous surgery. Diffuse enhancement occurred in 11 patients: eight with malignant infiltration, two with postoperative inflammation, and one with meningitis. Focal enhancement occurred in 12 patients, equally divided between those with malignant and benign processes: six cases were adjacent to intra- or extra-axial malignancy; three were at sites of recent (1--3 weeks) subarachnoid hemorrhage; and three were postoperative, adjacent to a craniotomy or subdural hematoma. Meningeal lesions were rarely diagnosed on the precontrast images, and Gd-DTPA enhancement was needed to distinguish between thickened meninges and thin fluid collections. Precontrast T1- and T2-weighted images were needed to discriminate high-signal meningeal enhancement from subacute subdural or subarachnoid hemorrhage, diploic marrow, normal vascular structures, and benign dural plaques. Meningeal enhancement was not pathology specific, and precontrast images are recommended to avoid misdiagnosis of subacute hemorrhage and misinterpretation of normal anatomy

  7. Multipeak Mean Based Optimized Histogram Modification Framework Using Swarm Intelligence for Image Contrast Enhancement

    Directory of Open Access Journals (Sweden)

    P. Babu

    2015-01-01

    Full Text Available A novel approach, Multipeak mean based optimized histogram modification framework (MMOHM is introduced for the purpose of enhancing the contrast as well as preserving essential details for any given gray scale and colour images. The basic idea of this technique is the calculation of multiple peaks (local maxima from the original histogram. The mean value of multiple peaks is computed and the input image’s histogram is segmented into two subhistograms based on this multipeak mean (mmean value. Then, a bicriteria optimization problem is formulated and the subhistograms are modified by selecting optimal contrast enhancement parameters. While formulating the enhancement parameters, particle swarm optimization is employed to find optimal values of them. Finally, the union of the modified subhistograms produces a contrast enhanced and details preserved output image. This mechanism enhances the contrast of the input image better than the existing contemporary HE methods. The performance of the proposed method is well supported by the contrast enhancement quantitative metrics such as discrete entropy, natural image quality evaluator, and absolute mean brightness error.

  8. Gadolinium diethylenetriamine pentaacetic acid enhanced magnetic resonance imagings in cardiomyopathic hamsters. Histopathologic correlation

    International Nuclear Information System (INIS)

    Aso, Hiroko

    1995-01-01

    To assess the significance of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA)-enhanced magnetic resonance (MR) imaging, the findings were correlated with histopathological findings in cardiomyopathic hamsters (Bio 14.6). In hamsters given 1 mBq of Gd-DTPA, autoradiography revealed uptake of Gd-DTPA corresponding to the fibrotic tissue. According to the degree of fibrosis and inflammation, the tissue was graded into three. The ratio of contrast enhancement in the fibrotic area to that in the normal area was significantly higher in grade 1 than grades 2 and 3, and in grade 2 than grade 3. Next, hamsters in various age groups were given 0.2 mmol/kg intravenously. In the age group of 2-5 month, contrast enhancement was homogeneously observed in the entire myocardium. In the age group of 8-10 years, it was entirely observed, partly with heterogeneous enhancement. In the age group of 11-12 years, contrast enhancement was not different from that in the normal hamsters. Histological examination revealed that fibrosis changed from grade 1 through grade 3 with advancing age. In conclusion, MR imaging for myocardiopathy showed signal intensity reflecting the fibrotic tissue. Contrast enhancement of MR imaging was stronger when much more inflammatory cells were involved and fibrotic tissues were filled with much more blood vessels. Thus MR imaging may be a promising tool for evaluating the severity of myocardiopathy. (N.K.)

  9. Achieving best practices in national standardisation. A benchmarking study of the national standardisation systems of Finland, Sweden, Denmark and Italy

    International Nuclear Information System (INIS)

    Bonner, P.; Potter, D.

    2000-01-01

    The national standardisation systems of Finland, Sweden, Denmark and Italy have been benchmarked in a study that has sought to identify best practices for improving the performance of all participating bodies. This study has been funded by the Ministry of Trade and Industry of Finland with some assistance from the European Commission. It has involved a series of 27 interviews of some 120 participants at different levels in the standardisation and wider stakeholder communities. This report details the features of each national system and describes more than 50 best practices identified during the course of the study, together with more than 25 recommendations for further improvements that are drawn from best practices in other organisations. The report starts by identifying best practices in the national standardisation systems and their structures and processes before moving onto the participation in European and international standardisation, with their challenges of influence, management and delivery. The relationship with government, at national level and within European programmes, is then addressed before moving onto the financing of standardisation activities within each of the national systems. The focus then starts moving more towards the national standards bodies (SFS,SIS,DS,UNI/CEI) by looking into issues relating to publications and onto customer services, sales and marketing. Management issues and the benefits of a long term strategic approach are then covered before moving on to the issues associated with communications and outreach, not only to those outside of the standards community but also those within it and on its edges. Moreover, trends during the last five years and those expected within the next two are dealt with briefly. A number of recommendations are common to all of the participating bodies. More detailed recommendations and suggested priorities have been made privately in a further set of reports delivered to the participating bodies

  10. Bas-relief map using texture analysis with application to live enhancement of ultrasound images.

    Science.gov (United States)

    Du, Huarui; Ma, Rui; Wang, Xiaoying; Zhang, Jue; Fang, Jing

    2015-05-01

    For ultrasound imaging, speckle is one of the most important factors in the degradation of contrast resolution because it masks meaningful texture and has the potential to interfere with diagnosis. It is expected that researchers would explore appropriate ways to reduce the speckle noise, to find the edges of structures and enhance weak borders between different organs in ultrasound imaging. Inspired by the principle of differential interference contrast microscopy, a "bas-relief map" is proposed that depicts the texture structure of ultrasound images. Based on a bas-relief map, an adaptive bas-relief filter was developed for ultrafast despeckling. Subsequently, an edge map was introduced to enhance the edges of images in real time. The holistic bas-relief map approach has been used experimentally with synthetic phantoms and digital ultrasound B-scan images of liver, kidney and gallbladder. Based on the visual inspection and the performance metrics of the despeckled images, it was found that the bas-relief map approach is capable of effectively reducing the speckle while significantly enhancing contrast and tissue boundaries for ultrasonic images, and its speckle reduction ability is comparable to that of Kuan, Lee and Frost filters. Meanwhile, the proposed technique could preserve more intra-region details compared with the popular speckle reducing anisotropic diffusion technique and more effectively enhance edges. In addition, the adaptive bas-relief filter was much less time consuming than the Kuan, Lee and Frost filter and speckle reducing anisotropic diffusion techniques. The bas-relief map strategy is effective for speckle reduction and live enhancement of ultrasound images, and can provide a valuable tool for clinical diagnosis. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Image accuracy and representational enhancement through low-level, multi-sensor integration techniques

    International Nuclear Information System (INIS)

    Baker, J.E.

    1993-05-01

    Multi-Sensor Integration (MSI) is the combining of data and information from more than one source in order to generate a more reliable and consistent representation of the environment. The need for MSI derives largely from basic ambiguities inherent in our current sensor imaging technologies. These ambiguities exist as long as the mapping from reality to image is not 1-to-1. That is, if different 44 realities'' lead to identical images, a single image cannot reveal the particular reality which was the truth. MSI techniques can be divided into three categories based on the relative information content of the original images with that of the desired representation: (1) ''detail enhancement,'' wherein the relative information content of the original images is less rich than the desired representation; (2) ''data enhancement,'' wherein the MSI techniques axe concerned with improving the accuracy of the data rather than either increasing or decreasing the level of detail; and (3) ''conceptual enhancement,'' wherein the image contains more detail than is desired, making it difficult to easily recognize objects of interest. In conceptual enhancement one must group pixels corresponding to the same conceptual object and thereby reduce the level of extraneous detail. This research focuses on data and conceptual enhancement algorithms. To be useful in many real-world applications, e.g., autonomous or teleoperated robotics, real-time feedback is critical. But, many MSI/image processing algorithms require significant processing time. This is especially true of feature extraction, object isolation, and object recognition algorithms due to their typical reliance on global or large neighborhood information. This research attempts to exploit the speed currently available in state-of-the-art digitizers and highly parallel processing systems by developing MSI algorithms based on pixel rather than global-level features

  12. Spatial resolution enhancement of satellite image data using fusion approach

    Science.gov (United States)

    Lestiana, H.; Sukristiyanti

    2018-02-01

    Object identification using remote sensing data has a problem when the spatial resolution is not in accordance with the object. The fusion approach is one of methods to solve the problem, to improve the object recognition and to increase the objects information by combining data from multiple sensors. The application of fusion image can be used to estimate the environmental component that is needed to monitor in multiple views, such as evapotranspiration estimation, 3D ground-based characterisation, smart city application, urban environments, terrestrial mapping, and water vegetation. Based on fusion application method, the visible object in land area has been easily recognized using the method. The variety of object information in land area has increased the variation of environmental component estimation. The difficulties in recognizing the invisible object like Submarine Groundwater Discharge (SGD), especially in tropical area, might be decreased by the fusion method. The less variation of the object in the sea surface temperature is a challenge to be solved.

  13. Task-based strategy for optimized contrast enhanced breast imaging: Analysis of six imaging techniques for mammography and tomosynthesis

    Science.gov (United States)

    Ikejimba, Lynda C.; Kiarashi, Nooshin; Ghate, Sujata V.; Samei, Ehsan; Lo, Joseph Y.

    2014-01-01

    Purpose: The use of contrast agents in breast imaging has the capability of enhancing nodule detectability and providing physiological information. Accordingly, there has been a growing trend toward using iodine as a contrast medium in digital mammography (DM) and digital breast tomosynthesis (DBT). Widespread use raises concerns about the best way to use iodine in DM and DBT, and thus a comparison is necessary to evaluate typical iodine-enhanced imaging methods. This study used a task-based observer model to determine the optimal imaging approach by analyzing six imaging paradigms in terms of their ability to resolve iodine at a given dose: unsubtracted mammography and tomosynthesis, temporal subtraction mammography and tomosynthesis, and dual energy subtraction mammography and tomosynthesis. Methods: Imaging performance was characterized using a detectability index d′, derived from the system task transfer function (TTF), an imaging task, iodine signal difference, and the noise power spectrum (NPS). The task modeled a 10 mm diameter lesion containing iodine concentrations between 2.1 mg/cc and 8.6 mg/cc. TTF was obtained using an edge phantom, and the NPS was measured over several exposure levels, energies, and target-filter combinations. Using a structured CIRS phantom, d′ was generated as a function of dose and iodine concentration. Results: For all iodine concentrations and dose, temporal subtraction techniques for mammography and tomosynthesis yielded the highest d′, while dual energy techniques for both modalities demonstrated the next best performance. Unsubtracted imaging resulted in the lowest d′ values for both modalities, with unsubtracted mammography performing the worst out of all six paradigms. Conclusions: At any dose, temporal subtraction imaging provides the greatest detectability, with temporally subtracted DBT performing the highest. The authors attribute the successful performance to excellent cancellation of inplane structures and

  14. Detection of pericardial inflammation with late-enhancement cardiac magnetic resonance imaging: initial results

    International Nuclear Information System (INIS)

    Taylor, Andrew M.; Dymarkowski, Steven; Bogaert, Jan; Verbeken, Eric K.

    2006-01-01

    To examine the value of late-enhancement cardiac magnetic resonance imaging (MRI) for detection of pericardial inflammation. Late-enhancement cardiac MRI was performed in 16 patients with clinical suspicion of pericardial disease. Pericardial effusion, pericardial thickening and pericardial enhancement were assessed. MRI findings were compared with those of definitive pericardial histology (n=14) or microbiology (n=2). A control group of 12 patients with no clinical evidence of pericardial disease were also imaged with the same MRI protocol. Sensitivity and specificity for late-enhancement MRI detection of pericardial inflammation was of 100%. There was MRI late enhancement of the pericardial layers in all five patients with histological/microbiological evidence of inflammatory pericarditis. MRI demonstrated no pericardial thickening and no MRI late enhancement with or without a pericardial effusion in any of the five patients with histological evidence of a normal pericardium. MRI detected pericardial thickening in the absence of both pericardial effusion and late enhancement in all six patients with histological evidence of chronic fibrosing pericarditis. The 12 control subjects showed no evidence of pericardial MRI late enhancement. These findings demonstrate that MRI late enhancement can be used to visualize pericardial inflammation in patients with clinical suspicion of pericardial disease. (orig.)

  15. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients

    International Nuclear Information System (INIS)

    Jochens, R.; Henkes, H.; Steinkamp, H.J.; Terstegge, K.; Hosten, N.; Ruf, B.; Schoerner, W.

    1994-01-01

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. As a result, T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [de

  16. Image enhancement by spectral-error correction for dual-energy computed tomography.

    Science.gov (United States)

    Park, Kyung-Kook; Oh, Chang-Hyun; Akay, Metin

    2011-01-01

    Dual-energy CT (DECT) was reintroduced recently to use the additional spectral information of X-ray attenuation and aims for accurate density measurement and material differentiation. However, the spectral information lies in the difference between low and high energy images or measurements, so that it is difficult to acquire accurate spectral information due to amplification of high pixel noise in the resulting difference image. In this work, an image enhancement technique for DECT is proposed, based on the fact that the attenuation of a higher density material decreases more rapidly as X-ray energy increases. We define as spectral error the case when a pixel pair of low and high energy images deviates far from the expected attenuation trend. After analyzing the spectral-error sources of DECT images, we propose a DECT image enhancement method, which consists of three steps: water-reference offset correction, spectral-error correction, and anti-correlated noise reduction. It is the main idea of this work that makes spectral errors distributed like random noise over the true attenuation and suppressed by the well-known anti-correlated noise reduction. The proposed method suppressed noise of liver lesions and improved contrast between liver lesions and liver parenchyma in DECT contrast-enhanced abdominal images and their two-material decomposition.

  17. FFT-enhanced IHS transform method for fusing high-resolution satellite images

    Science.gov (United States)

    Ling, Y.; Ehlers, M.; Usery, E.L.; Madden, M.

    2007-01-01

    Existing image fusion techniques such as the intensity-hue-saturation (IHS) transform and principal components analysis (PCA) methods may not be optimal for fusing the new generation commercial high-resolution satellite images such as Ikonos and QuickBird. One problem is color distortion in the fused image, which causes visual changes as well as spectral differences between the original and fused images. In this paper, a fast Fourier transform (FFT)-enhanced IHS method is developed for fusing new generation high-resolution satellite images. This method combines a standard IHS transform with FFT filtering of both the panchromatic image and the intensity component of the original multispectral image. Ikonos and QuickBird data are used to assess the FFT-enhanced IHS transform method. Experimental results indicate that the FFT-enhanced IHS transform method may improve upon the standard IHS transform and the PCA methods in preserving spectral and spatial information. ?? 2006 International Society for Photogrammetry and Remote Sensing, Inc. (ISPRS).

  18. Gadolinium-DTPA enhanced magnetic resonance imaging of bone cysts in patients with rheumatoid arthritis.

    Science.gov (United States)

    Gubler, F M; Algra, P R; Maas, M; Dijkstra, P F; Falke, T H

    1993-01-01

    OBJECTIVES--To examine the contents of intraosseous cysts in patients with rheumatoid arthritis (RA) through the signal intensity characteristics on gadolinium-DTPA (Gd-DTPA) enhanced magnetic resonance imaging. METHODS--The hand or foot joints of nine patients with the cystic form of RA (where the initial radiological abnormality consisted of intraosseous cysts without erosions) were imaged before and after intravenous administration of Gd-DTPA. A 0.6 unit, T1 weighted spin echo and T2* weighted gradient echo were used to obtain images in at least two perpendicular planes. RESULTS--Most cysts showed a low signal intensity on the non-enhanced T1 weighted (spin echo) images and a high signal intensity on the T2* weighted (gradient echo) images, consistent with a fluid content. No cyst showed an enhancement of signal intensity on the T1 weighted images after intravenous administration of Gd-DTPA, whereas synovium hyperplasia at the site of bony erosions did show an increased signal intensity after Gd-DTPA. Magnetic resonance imaging detected more cysts (as small as 2 mm) than plain films, and the cysts were located truly intraosseously. In six patients no other joint abnormalities were identified by magnetic resonance imaging; the three other patients also showed, after Gd-DTPA administration, an enhanced synovium at the site of bony erosions. CONCLUSIONS--It is suggested that intraosseous bone cysts in patients with RA do not contain hyperaemic synovial proliferation. The bone cysts in patients with the cystic form of RA may be the only joint abnormality. Images PMID:8257207

  19. Enhanced

    Directory of Open Access Journals (Sweden)

    Martin I. Bayala

    2014-06-01

    Full Text Available Land Surface Temperature (LST is a key parameter in the energy balance model. However, the spatial resolution of the retrieved LST from sensors with high temporal resolution is not accurate enough to be used in local-scale studies. To explore the LST–Normalised Difference Vegetation Index relationship potential and obtain thermal images with high spatial resolution, six enhanced image sharpening techniques were assessed: the disaggregation procedure for radiometric surface temperatures (TsHARP, the Dry Edge Quadratic Function, the Difference of Edges (Ts∗DL and three models supported by the relationship of surface temperature and water stress of vegetation (Normalised Difference Water Index, Normalised Difference Infrared Index and Soil wetness index. Energy Balance Station data and in situ measurements were used to validate the enhanced LST images over a mixed agricultural landscape in the sub-humid Pampean Region of Argentina (PRA, during 2006–2010. Landsat Thematic Mapper (TM and Moderate Resolution Imaging Spectroradiometer (EOS-MODIS thermal datasets were assessed for different spatial resolutions (e.g., 960, 720 and 240 m and the performances were compared with global and local TsHARP procedures. Results suggest that the Ts∗DL technique is the most adequate for simulating LST to high spatial resolution over the heterogeneous landscape of a sub-humid region, showing an average root mean square error of less than 1 K.

  20. On image quality enhancement in photoacoustic image reconstruction by motion compensation

    NARCIS (Netherlands)

    Willemink, Rene; Slump, Cornelis H.; van der Heijden, Ferdinand

    2006-01-01

    Photoacoustic (PA) imaging is a relatively new noninvasive medical imaging modality. It is a tech- nique which is harmless for the human body and uses pulsed optical energy. The process is based on the ab- sorption of the pulse of optical energy by an object leading to local temperature increases.

  1. Enhancement of spatial resolution of terahertz imaging systems based on terajet generation by dielectric cube

    Directory of Open Access Journals (Sweden)

    Hai Huy Nguyen Pham

    2017-05-01

    Full Text Available The terahertz (THz, 0.1–10 THz region has been attracting tremendous research interest owing to its potential in practical applications such as biomedical, material inspection, and nondestructive imaging. Those applications require enhancing the spatial resolution at a specific frequency of interest. A variety of resolution-enhancement techniques have been proposed, such as near-field scanning probes, surface plasmons, and aspheric lenses. Here, we demonstrate for the first time that a mesoscale dielectric cube can be exploited as a novel resolution enhancer by simply placing it at the focused imaging point of a continuous wave THz imaging system. The operating principle of this enhancer is based on the generation—by the dielectric cuboid—of the so-called terajet, a photonic jet in the THz region. A subwavelength hotspot is obtained by placing a Teflon cube, with a 1.46 refractive index, at the imaging point of the imaging system, regardless of the numerical aperture (NA. The generated terajet at 125 GHz is experimentally characterized, using our unique THz-wave visualization system. The full width at half maximum (FWHM of the hotspot obtained by placing the enhancer at the focal point of a mirror with a measured NA of 0.55 is approximately 0.55λ, which is even better than the FWHM obtained by a conventional focusing device with the ideal maximum numerical aperture (NA = 1 in air. Nondestructive subwavelength-resolution imaging demonstrations of a Suica integrated circuit card, which is used as a common fare card for trains in Japan, and an aluminum plate with 0.63λ trenches are presented. The amplitude and phase images obtained with the enhancer at 125 GHz can clearly resolve both the air-trenches on the aluminum plate and the card’s inner electronic circuitry, whereas the images obtained without the enhancer are blurred because of insufficient resolution. An increase of the image contrast by a factor of 4.4 was also obtained using

  2. Vessel Enhancement and Segmentation of 4D CT Lung Image Using Stick Tensor Voting

    Science.gov (United States)

    Cong, Tan; Hao, Yang; Jingli, Shi; Xuan, Yang

    2016-12-01

    Vessel enhancement and segmentation plays a significant role in medical image analysis. This paper proposes a novel vessel enhancement and segmentation method for 4D CT lung image using stick tensor voting algorithm, which focuses on addressing the vessel distortion issue of vessel enhancement diffusion (VED) method. Furthermore, the enhanced results are easily segmented using level-set segmentation. In our method, firstly, vessels are filtered using Frangi's filter to reduce intrapulmonary noises and extract rough blood vessels. Secondly, stick tensor voting algorithm is employed to estimate the correct direction along the vessel. Then the estimated direction along the vessel is used as the anisotropic diffusion direction of vessel in VED algorithm, which makes the intensity diffusion of points locating at the vessel wall be consistent with the directions of vessels and enhance the tubular features of vessels. Finally, vessels can be extracted from the enhanced image by applying level-set segmentation method. A number of experiments results show that our method outperforms traditional VED method in vessel enhancement and results in satisfied segmented vessels.

  3. Low flip angle spin-echo MR imaging to obtain better Gd-DTPA enhanced imaging with ECG gating

    International Nuclear Information System (INIS)

    Sugimura, Kazuro; Kawamitsu, Hideaki; Yoshikawa, Kazuaki; Kasai, Toshifumi; Yuasa, Koji; Ishida, Tetsuya

    1992-01-01

    ECG-gated spin-echo imaging (ECG-SE) can reduce physiological motion artifact. However, ECG-SE does not provide strong T1-weighted images because repetition time (TR) depends on heart rate (HR). We investigated the usefulness of low flip angle spin-echo imaging (LFSE) in obtaining more T1-dependent contrast with ECG gating. In computer simulation, the predicted image contrast and single-to-noise ratio (SNR) obtained for each flip angle (0-180deg) and each TR (300 msec-1200 msec) were compared with those obtained by conventional T1-weighted spin-echo imaging (CSE: TR=500 msec, TE=20 msec). In clinical evaluation, tissue contrast [contrast index (CI): (SI of lesion-SI of muslce) 2* 100/SI of muscle] obtained by CSE and LFSE were compared in 17 patients. At a TR of 1,000 msec, T1-dependent contrast increased with decreasing flip angle and that at 38deg was identical to that with T1-weighted spin-echo. SNR increased with the flip angle until 100deg, and that at 53deg was identical to that with T1-weighted spin-echo. CI on LFSE (74.0±52.0) was significantly higher than CI on CSE (40.9±35.9). ECG-gated LFSE imaging provides better T1-dependent contrast than conventional ECG-SE. This method was especially useful for Gd-DTPA enhanced MR imaging. (author)

  4. Task-based strategy for optimized contrast enhanced breast imaging: analysis of six imaging techniques for mammography and tomosynthesis

    Science.gov (United States)

    Ikejimba, Lynda; Kiarashi, Nooshin; Lin, Yuan; Chen, Baiyu; Ghate, Sujata V.; Zerhouni, Moustafa; Samei, Ehsan; Lo, Joseph Y.

    2012-03-01

    Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique that provides 3D structural information of the breast. In contrast to 2D mammography, DBT minimizes tissue overlap potentially improving cancer detection and reducing number of unnecessary recalls. The addition of a contrast agent to DBT and mammography for lesion enhancement has the benefit of providing functional information of a lesion, as lesion contrast uptake and washout patterns may help differentiate between benign and malignant tumors. This study used a task-based method to determine the optimal imaging approach by analyzing six imaging paradigms in terms of their ability to resolve iodine at a given dose: contrast enhanced mammography and tomosynthesis, temporal subtraction mammography and tomosynthesis, and dual energy subtraction mammography and tomosynthesis. Imaging performance was characterized using a detectability index d', derived from the system task transfer function (TTF), an imaging task, iodine contrast, and the noise power spectrum (NPS). The task modeled a 5 mm lesion containing iodine concentrations between 2.1 mg/cc and 8.6 mg/cc. TTF was obtained using an edge phantom, and the NPS was measured over several exposure levels, energies, and target-filter combinations. Using a structured CIRS phantom, d' was generated as a function of dose and iodine concentration. In general, higher dose gave higher d', but for the lowest iodine concentration and lowest dose, dual energy subtraction tomosynthesis and temporal subtraction tomosynthesis demonstrated the highest performance.

  5. Comparative study of protoporphyrin IX fluorescence image enhancement methods to improve an optical imaging system for oral cancer detection

    Science.gov (United States)

    Jiang, Ching-Fen; Wang, Chih-Yu; Chiang, Chun-Ping

    2011-07-01

    Optoelectronics techniques to induce protoporphyrin IX fluorescence with topically applied 5-aminolevulinic acid on the oral mucosa have been developed to noninvasively detect oral cancer. Fluorescence imaging enables wide-area screening for oral premalignancy, but the lack of an adequate fluorescence enhancement method restricts the clinical imaging application of these techniques. This study aimed to develop a reliable fluorescence enhancement method to improve PpIX fluorescence imaging systems for oral cancer detection. Three contrast features, red-green-blue reflectance difference, R/B ratio, and R/G ratio, were developed first based on the optical properties of the fluorescence images. A comparative study was then carried out with one negative control and four biopsy confirmed clinical cases to validate the optimal image processing method for the detection of the distribution of malignancy. The results showed the superiority of the R/G ratio in terms of yielding a better contrast between normal and neoplastic tissue, and this method was less prone to errors in detection. Quantitative comparison with the clinical diagnoses in the four neoplastic cases showed that the regions of premalignancy obtained using the proposed method accorded with the expert's determination, suggesting the potential clinical application of this method for the detection of oral cancer.

  6. Role of Gd-DTPA enhanced fat-suppression MR imaging on ovarian tumors

    International Nuclear Information System (INIS)

    Kang, Heoung Keun; Moon, Woong Jae; Seo, Jeong Jin; Kim, Jae Kyu; Park, Jin Gyoon; Choi, Ho Sun

    1995-01-01

    To determine the value of Gd-DTPA enhanced fat-suppression (GEFS) MR imaging in the characterization and differentiation of benign from malignant ovarian tumors. MRI findings of thirty-seven patients with surgically proved 44 ovarian tumors (30 benign, 14 malignant) were studied retrospectively. MR imaging with conventional spin echo (CSE; T1-weighted image TR/TE 450/20, T2-weighted image TR/TE 3500/30, 90) and GEFS were performed with a 1.5T GE signa. MRI findings of tumors including cystic or solid, wall and septal thickness, necrosis, invasion to adjacent organ, ascites and lymphadenopathy were assessed separately by using CSE and GEFS images, and then tumors were characterized as benign or malignant. Compared with CSE image, GEFS MR image showed better visualization of solid component in 5 malignant lesions, wall thickness in 5 malignant and 1 benign lesions, septal thickness in 3 malignant and 1 benign lesions, necrosis in 1 malignant lesion, and adjacent soft tissue invasion in 5 malignant lesions. Correct characterization of malignant tumors was increased from 71% on CSE image to 93% on GEFS image. However, correct characterization of benign tumors was 93% on both images. GEFS MR imaging could be useful for characterization of ovarian tumors, especially in malignant cases, and employed for differentiation of benign from malignant tumors

  7. The Effect of Using Bizarre Images as Mnemonics to Enhance Vocabulary Learning

    Directory of Open Access Journals (Sweden)

    Hassan Saleh Mahdi

    2018-03-01

    Full Text Available Mnemonic is a technique that helps someone remember better. The combination of images with mnemonics can make it more powerful and effective to help language learners remember better and for a longer time. Acquiring L2 vocabulary can be enhanced by using images. In the previous studies, mnemonics were used traditionally, that is, learners were asked to create a mental image to remember a word or any new item. Several studies were conducted to explore the use of mental images as mnemonics for vocabulary learning. However, no study has examined the integration of images as a mnemonic tool for vocabulary acquisition. Therefore, this study aimed at investigating the effect of images as mnemonics on vocabulary acquisition. The study examined the effect of images as a mnemonic tool for vocabulary acquisition in three conditions (i.e. normal images, bizarre images and traditional way of learning vocabulary. Sixty Arab learners of English as a foreign language enrolled in the English Department at Hodeidah University participated in this study and were randomly assigned into three groups. This study used an experimental method in which pre-, post- and delayed post-tests were administered to these groups. The results indicated that mnemonics with the help of images are useful tools to help learners remember many words. Keywords: Bizarre images, Multimedia, Mnemonics, Vocabulary learning, Vocabulary retention.

  8. Sum of top-hat transform based algorithm for vessel enhancement in MRA images

    Science.gov (United States)

    Ouazaa, Hibet-Allah; Jlassi, Hajer; Hamrouni, Kamel

    2018-04-01

    The Magnetic Resonance Angiography (MRA) is rich with information's. But, they suffer from poor contrast, illumination and noise. Thus, it is required to enhance the images. But, these significant information can be lost if improper techniques are applied. Therefore, in this paper, we propose a new method of enhancement. We applied firstly the CLAHE method to increase the contrast of the image. Then, we applied the sum of Top-Hat Transform to increase the brightness of vessels. It is performed with the structuring element oriented in different angles. The methodology is tested and evaluated on the publicly available database BRAINIX. And, we used the measurement methods MSE (Mean Square Error), PSNR (Peak Signal to Noise Ratio) and SNR (Signal to Noise Ratio) for the evaluation. The results demonstrate that the proposed method could efficiently enhance the image details and is comparable with state of the art algorithms. Hence, the proposed method could be broadly used in various applications.

  9. Technical aspects of contrast-enhanced magnetic resonance imaging of the breast: literature review

    International Nuclear Information System (INIS)

    Leopoldino, Denise de Deus; Gracio, Tatiana Schiller; D'Ippolito, Giuseppe; Bezerra, Alexandre Sergio de Araujo; Gracio, Tatiana Schiller

    2005-01-01

    With the advances in surface coil technology and the development of new imaging protocols in addition to the increase of the use of contrast agents, contrast enhanced magnetic resonance imaging (MRI) has emerged as a promising modality for detection, diagnosis and staging of breast cancer. Despite these advances, there are some unresolved issues, including no defined standard technique for contrast-enhanced breast MRI and no standard criteria of interpretation for the evaluation of such studies. In this article, we review the literature and discuss the general requirements and recommendations for contrast agent-enhanced breast MRI, including image interpretation criteria, MR equipment, dedicated radiofrequency coils, use of paramagnetic contrast agents, fat-suppression techniques, planes of acquisition, pulse sequence specifications and artifact sources. (author)

  10. Underwater Image Enhancement by Adaptive Gray World and Differential Gray-Levels Histogram Equalization

    Directory of Open Access Journals (Sweden)

    WONG, S.-L.

    2018-05-01

    Full Text Available Most underwater images tend to be dominated by a single color cast. This paper presents a solution to remove the color cast and improve the contrast in underwater images. However, after the removal of the color cast using Gray World (GW method, the resultant image is not visually pleasing. Hence, we propose an integrated approach using Adaptive GW (AGW and Differential Gray-Levels Histogram Equalization (DHE that operate in parallel. The AGW is applied to remove the color cast while DHE is used to improve the contrast of the underwater image. The outputs of both chromaticity components of AGW and intensity components of DHE are combined to form the enhanced image. The results of the proposed method are compared with three existing methods using qualitative and quantitative measures. The proposed method increased the visibility of underwater images and in most cases produces better quantitative scores when compared to the three existing methods.

  11. Evaluation and technologic improvement of an enhanced imaging system

    International Nuclear Information System (INIS)

    Henry, D.

    1990-08-01

    Feature-based systems that combine imaging and signal analysis capabilities may be useful for nondestructive evaluation (NDE) of plant components. This report describes the metallurgical evaluation conducted to verify the performance of a feature-based system to discriminate intergranular stress corrosion cracking (IGSCC) from benign geometrical reflectors. The ultrasonic examination results were also evaluated by examination personnel trained in intergranular stress corrosion cracking (IGSCC) detection techniques. The welds were examined prior to their removal from the recirculation and Residual-Heat-Removal (RHR) piping systems of the Peach Bottom Atomic Power Plant, as described in the Phase 2 Interim Report issued in June 1989. In this phase of the program, a metallurgical evaluation was performed on piping system welds that were examined ultrasonically using a feature-based system for analysis. The feature-based system correctly identified crack, but incorrectly identified other features, e.g., root geometry and metallurgical interfaces, as cracks. While the results of the analysis by the feature-based system were not identical to the results of analysis by trained personnel, the overall performance of the feature-based system was comparable to that of the trained personnel. Based on the results of this program, the feature-based system may be useful as a supplementary method of identifying IGSCC indications. When used in conjunction with existing methods and techniques, it could improve the accuracy of IGSCC identification

  12. Quality Enhancement and Nerve Fibre Layer Artefacts Removal in Retina Fundus Images by Off Axis Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Tobin Jr, Kenneth William [ORNL; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2011-01-01

    Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relative low cost, these cameras are employed worldwide by retina specialists to diagnose diabetic retinopathy and other degenerative diseases. Even with relative ease of use, the images produced by these systems sometimes suffer from reflectance artefacts mainly due to the nerve fibre layer (NFL) or other camera lens related reflections. We propose a technique that employs multiple fundus images acquired from the same patient to obtain a single higher quality image without these reflectance artefacts. The removal of bright artefacts, and particularly of NFL reflectance, can have great benefits for the reduction of false positives in the detection of retinal lesions such as exudate, drusens and cotton wool spots by automatic systems or manual inspection. If enough redundant information is provided by the multiple images, this technique also compensates for a suboptimal illumination. The fundus images are acquired in straightforward but unorthodox manner, i.e. the stare point of the patient is changed between each shot but the camera is kept fixed. Between each shot, the apparent shape and position of all the retinal structures that do not exhibit isotropic reflectance (e.g. bright artefacts) change. This physical effect is exploited by our algorithm in order to extract the pixels belonging to the inner layers of the retina, hence obtaining a single artefacts-free image.

  13. Standardisation of 64Cu using a software coincidence counting system

    International Nuclear Information System (INIS)

    Havelka, Miroslav; Sochorová, Jana

    2014-01-01

    The activity of the radionuclide 64 Cu was determined by the efficiency extrapolation method applied to 4π(PC)−γ coincidence counting. The standardisation was performed by software coincidence counting—a digital method for primary activity measurement that simplifies the setting of optimal coincidence parameters. The γ-ray-energy window, characterised by identical gamma detection efficiency related to the sum of EC and to the sum of beta decay branches, was found. This setting ensured a linear and zero slope extrapolation curve. - Highlights: • Standardisation realised by extrapolation method applied to 4π(PC)−γ coincidence. • Digital method for optimal setting of coincidence parameters was used. • Result with total standard uncertainty of 0.74% was obtained

  14. Enhanced MR imaging of tenosynovitis of hand and wrist in inflammatory arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Tehranzadeh, J.; Ashilyan, O.; Anavim, A.; Tramma, S. [Univ. of California, Orange (United States). Dept. of Radiological Sciences

    2006-11-15

    The purpose of this study is to describe the appearance of tenosynovitis in various tendon groups in the wrist and hand and to compare MR enhanced and non-enhanced imaging evaluation of tenosynovitis of hand and wrist in inflammatory arthritis. We reviewed 72 MRI studies of hands and wrists, including coronal, axial and sagittal images in 30 consecutive patients with inflammatory arthritis and tenosynovitis. We compared the degree of synovitis on T2-weighted vs contrast-enhanced T1-weighted images, using a predetermined scale. We also measured the extent of tenosynovitis in three dimensions. The tendons were assigned to volar, dorsal, ulnar and radial groups in the wrist and to extensor, flexor and thumb groups in the hand. Degree of tenosynovitis (graded 0-3), cross-sectional area and volume of the inflamed synovium in various tendon groups were then compared by statistical analysis. Review of the medical records revealed the following diagnoses in our patient population: rheumatoid arthritis (n=16), unspecified inflammatory polyarthritis (n=9), psoriatic arthritis (n=2), CREST syndrome (n=1), systemic lupus erythematosus (n=1), paraneoplastic syndrome with arthritis (n=1). The average T2 brightness scores and post-gadolinium enhancement scores were 1.0 and 1.7 respectively (P<0.001) in the wrist studies. The average T2 brightness scores and post-gadolinium enhancement scores were 0.7 and 1.4, respectively (P<0.001) in the hand studies. The average sensitivity of T2-weighted imaging for detection of tenosynovitis was 40% in the hand and 67% in the wrist tendons, when contrast-enhanced images were used as a reference. Carpal tunnel flexor tendons were the most frequently affected tendons of the wrist. The most frequently affected tendons of the hand were second and third flexor tendons. The hand flexors demonstrated higher degrees of enhancement and larger volumes of the inflamed tenosynovium than did the hand extensors and tendons of the thumb.

  15. Enhanced MR imaging of tenosynovitis of hand and wrist in inflammatory arthritis

    International Nuclear Information System (INIS)

    Tehranzadeh, J.; Ashilyan, O.; Anavim, A.; Tramma, S.

    2006-01-01

    The purpose of this study is to describe the appearance of tenosynovitis in various tendon groups in the wrist and hand and to compare MR enhanced and non-enhanced imaging evaluation of tenosynovitis of hand and wrist in inflammatory arthritis. We reviewed 72 MRI studies of hands and wrists, including coronal, axial and sagittal images in 30 consecutive patients with inflammatory arthritis and tenosynovitis. We compared the degree of synovitis on T2-weighted vs contrast-enhanced T1-weighted images, using a predetermined scale. We also measured the extent of tenosynovitis in three dimensions. The tendons were assigned to volar, dorsal, ulnar and radial groups in the wrist and to extensor, flexor and thumb groups in the hand. Degree of tenosynovitis (graded 0-3), cross-sectional area and volume of the inflamed synovium in various tendon groups were then compared by statistical analysis. Review of the medical records revealed the following diagnoses in our patient population: rheumatoid arthritis (n=16), unspecified inflammatory polyarthritis (n=9), psoriatic arthritis (n=2), CREST syndrome (n=1), systemic lupus erythematosus (n=1), paraneoplastic syndrome with arthritis (n=1). The average T2 brightness scores and post-gadolinium enhancement scores were 1.0 and 1.7 respectively (P<0.001) in the wrist studies. The average T2 brightness scores and post-gadolinium enhancement scores were 0.7 and 1.4, respectively (P<0.001) in the hand studies. The average sensitivity of T2-weighted imaging for detection of tenosynovitis was 40% in the hand and 67% in the wrist tendons, when contrast-enhanced images were used as a reference. Carpal tunnel flexor tendons were the most frequently affected tendons of the wrist. The most frequently affected tendons of the hand were second and third flexor tendons. The hand flexors demonstrated higher degrees of enhancement and larger volumes of the inflamed tenosynovium than did the hand extensors and tendons of the thumb

  16. Multiphase contrast-enhanced magnetic resonance imaging features of Bacillus Calmette-Guerin-induced granulomatous prostatitis in five patients

    Energy Technology Data Exchange (ETDEWEB)

    Kawada, Hiroshi; Kanematsu, Masayuki; Goshima, Satoshi; Kondo, Hiroshi; Watanabe, Haruo; Noda, Yoshifumi; Tanahashi, Yukichi; Kawai, Nobuyuki; Hoshi, Hiroaki [Gifu University Hospital, Gifu (Japan)

    2015-04-15

    To evaluate the multiphase contrast-enhanced magnetic resonance (MR) imaging features of Bacillus Calmette-Guerin (BCG)-induced granulomatous prostatitis (GP). Magnetic resonance images obtained from five patients with histopathologically proven BCG-induced GP were retrospectively analyzed for tumor location, size, signal intensity on T2-weighted images (T2WI) and diffusion-weighted images (DWI), apparent diffusion coefficient (ADC) value, and appearance on gadolinium-enhanced multiphase images. MR imaging findings were compared with histopathological findings. Bacillus Calmette-Guerin-induced GP (size range, 9-40 mm; mean, 21.2 mm) were identified in the peripheral zone in all patients. The T2WI showed lower signal intensity compared with the normal peripheral zone. The DWIs demonstrated high signal intensity and low ADC values (range, 0.44-0.68 x 10(-3) mm2/sec; mean, 0.56 x 10(-3) mm2/sec), which corresponded to GP. Gadolinium-enhanced multiphase MR imaging performed in five patients showed early and prolonged ring enhancement in all cases of GP. Granulomatous tissues with central caseation necrosis were identified histologically, which corresponded to ring enhancement and a central low intensity area on gadolinium-enhanced MR imaging. The findings on T2WI, DWI, and gadolinium-enhanced images became gradually obscured with time. Bacillus Calmette-Guerin-induced GP demonstrates early and prolonged ring enhancement on gadolinium-enhanced MR imaging which might be a key finding to differentiate it from prostate cancer.

  17. Contrast-enhanced MR imaging of the endolymphatic sac in patients with sudden hearing loss

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Koshikawa, Tokiko; Fukatsu, Hiroshi; Ishigaki, Takeo; Nakashima, Tsutomu; Ichinose, Nobuyasu

    2002-01-01

    Our objective was to evaluate the frequency of contrast enhancement of the endolymphatic sac in patients with sudden hearing loss. Forty consecutive patients with sudden sensorineural hearing loss (20 males and 20 females; age range 11-82 years), 40 age-matched control subjects, and 5 patients with Meniere's disease were examined using the same imaging protocol on a 1.5-T MR system. Pre- and post-contrast-enhanced T1-weighted 3D spoiled gradient-echo sequence (3D SPGR; TR/TE=23/10 ms, no. of excitations=1, flip angle=30 ) images were obtained using a voxel size of 0.6 x 0.7 x 0.8 mm 3 . Contrast enhancement in the area of the endolymphatic sac was assessed by two