WorldWideScience

Sample records for enhanced radiometric detection

  1. Enhanced radiometric detection of Mycobacterium paratuberculosis by using filter-concentrated bovine fecal specimens

    International Nuclear Information System (INIS)

    Collins, M.T.; Kenefick, K.B.; Sockett, D.C.; Lambrecht, R.S.; McDonald, J.; Jorgensen, J.B.

    1990-01-01

    A commercial radiometric medium, BACTEC 12B, was modified by addition of mycobactin, egg yolk suspension, and antibiotics (vancomycin, amphotericin B, and nalidixic acid). Decontaminated bovine fecal specimens were filter concentrated by using 3-microns-pore-size, 13-mm-diameter polycarbonate filters, and the entire filter was placed into the radiometric broth. Comparison of the radiometric technique with conventional methods on 603 cattle from 9 Mycobacterium paratuberculosis-infected herds found that of 75 positive specimens, the radiometric technique detected 92% while conventional methods detected 60% (P less than 0.0005). Only 3.9% of radiometric cultures were contaminated. To measure the effect of filter concentration of specimens on the detection rate, 5 cattle with minimal and 5 with moderate ileum histopathology were sampled weekly for 3 weeks. M. paratuberculosis was detected in 33.3% of nonfiltered specimens and 76.7% of filtered specimens (P less than 0.005). Detection rates were directly correlated with the severity of disease, and the advantage of specimen concentration was greatest on fecal specimens from cattle with low-grade infections. Detection times were also correlated with infection severity: 13.4 +/- 5.9 days with smear-positive specimens, 27.9 +/- 8.7 days with feces from cows with typical subclinical infections, and 38.7 +/- 3.8 days with fecal specimens from cows with low-grade infections. Use of a cocktail of vancomycin, amphotericin B, and nalidixic acid for selective suppression of nonmycobacterial contaminants was better than the commercial product PANTA (Becton Dickinson Microbiologic Systems, Towson, Md.) only when specimens contained very low numbers of M. paratuberculosis

  2. Automated radiometric detection of bacteria

    International Nuclear Information System (INIS)

    Waters, J.R.

    1974-01-01

    A new radiometric method called BACTEC, used for the detection of bacteria in cultures or in supposedly sterile samples, was discussed from the standpoint of methodology, both automated and semi-automated. Some of the results obtained so far were reported and some future applications and development possibilities were described. In this new method, the test sample is incubated in a sealed vial with a liquid culture medium containing a 14 C-labeled substrate. If bacteria are present, they break down the substrate, producing 14 CO 2 which is periodically extracted from the vial as a gas and is tested for radioactivity. If this gaseous radioactivity exceeds a threshold level, it is evidence of bacterial presence and growth in the test vial. The first application was for the detection of bacteria in the blood cultures of hospital patients. Data were presented showing typical results. Also discussed were future applications, such as rapid screening for bacteria in urine industrial sterility testing and the disposal of used 14 C substrates. (Mukohata, S.)

  3. Radiometric detection of yeasts in blood cultures of cancer patients

    International Nuclear Information System (INIS)

    Hopfer, R.L.; Orengo, A.; Chesnut, S.; Wenglar, M.

    1980-01-01

    During a 12-month period, 19,457 blood cultures were collected. Yeasts were isolated from 193 cultures derived from 76 cancer patients. Candida albicans or Candida tropicalis accounted for 79% of isolates. Of the three methods compared, the radiometric method required 2.9 days to become positive, blind subculture required 2.6 days, and Gram stains required 1 day. However, the radiometric method was clearly superior in detecting positive cultures, since 73% of all cultures were first detected radiometrically, 22% were detected by subculture, and only 5% were detected by Gram stain. Although 93% of the isolates were detected by aerobic culture, five (7%) isolates were obtained only from anaerobic cultures. Seven days of incubation appear to be sufficient for the radiometric detection of yeasts

  4. Method and apparatus for enhancing radiometric imaging

    International Nuclear Information System (INIS)

    Logan, R. H.; Paradish, F. J.

    1985-01-01

    Disclosed is a method and apparatus for enhancing target detection, particularly in the millimeter wave frequency range, through the utilization of an imaging radiometer. The radiometer, which is a passive thermal receiver, detects the reflected and emitted thermal radiation of targets within a predetermined antenna/receiver beamwidth. By scanning the radiometer over a target area, a thermal image is created. At millimeter wave frequencies, the received emissions from the target area are highly dependent on the emissivity of the target of interest. Foliage will appear ''hot'' due to its high emissivity and metals will appear cold due to their low emissivities. A noise power illuminator is periodically actuated to illuminate the target of interest. When the illuminator is actuated, the role of emissivity is reversed, namely poorly emissive targets will generally be good reflectors which in the presence of an illuminator will appear ''hot''. The highly emissive targets (such as foliage and dirt) which absorb most of the transmitted energy will appear almost the same as in a nonilluminated, passive image. Using a data processor, the intensity of the passive image is subtracted from the intensity of the illuminated, active image which thereby cancels the background foliage, dirt, etc. and the reflective metallic targets are enhanced

  5. Rapid radiometric method for detection of Salmonella in foods

    International Nuclear Information System (INIS)

    Stewart, B.J.; Eyles, M.J.; Murrell, W.G.

    1980-01-01

    A radiometric method for the detection of Salmonella in foods has been developed which is based on Salmonella poly H agglutinating serum preventing Salmonella from producing 14CO2 from [14C] dulcitol. The method will detect the presence or absence of Salmonella in a product within 30 h compared to 4 to 5 days by routine culture methods. The method has been evaluated against a routine culture method using 58 samples of food. The overall agreement was 91%. Five samples negative for Salmonella by the routine method were positive by the radiometric method. These may have been false positives. However, the routine method may have failed to detect Salmonella due to the presence of large numbers of lactose-fermenting bacteria which hindered isolation of Salmonella colonies on the selective agar plates

  6. Detection of corrosion by a radiometric technique

    International Nuclear Information System (INIS)

    Charlton, J.S.; Ross, J.F.

    1975-01-01

    A method is described for the detection and measurement of corrosion in metal tube bundles using a radioisotope technique. The method is stated to be accurate and quick, and dismantling is unnecessary. A radioactive source is inserted into one of the tubes of the bundle and radiation detectors are inserted into the remainder of the tubes, which may be up to six in number with the apparatus described. The radiation absorption by the walls of each pair of tubes is compared with a standard measurement representing a known thickness of the material of the tubes. Simultaneous measurements may be made. Suitable apparatus is described in detail. (U.K.)

  7. Radiometric method for the rapid detection of Leptospira organisms

    International Nuclear Information System (INIS)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-01-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with 14 C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques

  8. Radiometric method for the rapid detection of Leptospira organisms

    Energy Technology Data Exchange (ETDEWEB)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-02-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with /sup 14/C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques.

  9. On the lower of limit detection of radiometric systems

    International Nuclear Information System (INIS)

    Kamburov, H.; Boneva, S.

    1983-01-01

    The existing definitions of the quantity Asub(min), the lower detection limit, introduced as a characteristic of the sensitivity of radiometric systems are reviewed. A convenient way is found for comparing the different definitions by showing that each definition is connected with a specific value of the probability a of Type I error. The detection limits are calculated for a normal and Poisson distributions of the measured quantities. A criterion is proposed for the applicability of the normal distiribution to the problem of determining the lower detection limit

  10. MTG infrared sounder detection chain: first radiometric test results

    Science.gov (United States)

    Dumestier, D.; Pistone, F.; Dartois, T.; Blazquez, E.

    2017-11-01

    Europe's next fleet of geostationary meteorological satellites, MeteoSat Third Generation, will introduce new functions in addition to continuity of high-resolution meteorological data. The atmosphere Infrared Sounder (IRS), as high -end instrument, is part of this challenging program. IRS principle is a Fourier Transform Interferometer, which allows recomposing atmospheric spectrum after infrared photons detection. Transmission spectrums will be used to support numerical weather prediction. IRS instrument is able to offer full disk coverage in one hour, an on-ground resolution of 4 by 4 km, in two spectral bands (MWIR: 1600 to 2175cm-1 and LWIR: 700 to 1210cm-1) with a spectral resolution of 0.6cm-1. Among critical technologies and processes, IRS detection chain shall offer outstanding characteristics in terms of radiometric performance like Signal to Noise Ratio (SNR), dynamic range and linearity. Selected detectors are HgCdTe two-dimensions arrays, cooled at 55 Kelvins, hybridized on snapshot silicon read-out circuit at 160x160 format. Video electronics present 16 bits resolution, and the whole detection chain (Detectors and electronics) permits to reach SNR between 2 000 and 10 000 as requested by the application. Radiometric onground test results performed on design representative detection chains are presented and are confirming the challenging phase A design choices.

  11. Detection and recovery of mycobacteria by a radiometric procedure

    International Nuclear Information System (INIS)

    Takahashi, H.; Foster, V.

    1983-01-01

    During a 6-month period, 5,375 clinical specimens were cultured on Middlebrook-Cohn 7H10 medium, on Lowenstein-Jensen medium, and in Middlebrook 7H12 medium containing [ 14 C]palmitic acid. More mycobacteria were recovered when all three media were used than when either the conventional method with 7H10 agar and Lowenstein-Jensen slants or the radiometric method with 7H12 broth was used alone

  12. A simple and effective radiometric correction method to improve landscape change detection across sensors and across time

    Science.gov (United States)

    Chen, X.; Vierling, Lee; Deering, D.

    2005-01-01

    Satellite data offer unrivaled utility in monitoring and quantifying large scale land cover change over time. Radiometric consistency among collocated multi-temporal imagery is difficult to maintain, however, due to variations in sensor characteristics, atmospheric conditions, solar angle, and sensor view angle that can obscure surface change detection. To detect accurate landscape change using multi-temporal images, we developed a variation of the pseudoinvariant feature (PIF) normalization scheme: the temporally invariant cluster (TIC) method. Image data were acquired on June 9, 1990 (Landsat 4), June 20, 2000 (Landsat 7), and August 26, 2001 (Landsat 7) to analyze boreal forests near the Siberian city of Krasnoyarsk using the normalized difference vegetation index (NDVI), enhanced vegetation index (EVI), and reduced simple ratio (RSR). The temporally invariant cluster (TIC) centers were identified via a point density map of collocated pixel VIs from the base image and the target image, and a normalization regression line was created to intersect all TIC centers. Target image VI values were then recalculated using the regression function so that these two images could be compared using the resulting common radiometric scale. We found that EVI was very indicative of vegetation structure because of its sensitivity to shadowing effects and could thus be used to separate conifer forests from deciduous forests and grass/crop lands. Conversely, because NDVI reduced the radiometric influence of shadow, it did not allow for distinctions among these vegetation types. After normalization, correlations of NDVI and EVI with forest leaf area index (LAI) field measurements combined for 2000 and 2001 were significantly improved; the r 2 values in these regressions rose from 0.49 to 0.69 and from 0.46 to 0.61, respectively. An EVI "cancellation effect" where EVI was positively related to understory greenness but negatively related to forest canopy coverage was evident across a

  13. Improved detection of Mycobacterium avium complex with the Bactec radiometric system

    International Nuclear Information System (INIS)

    Hoffner, S.E.

    1988-01-01

    A reconsideration of the laboratory methods used for primary isolation of mycobacteria other than Mycobacterium tuberculosis is needed due to the increasingly recognized importance of such mycobacterial infections in immunocompromised patients. One example of this is the severe opportunistic infections caused by Mycobacterium avium complex among AIDS patients. In this study, the Bactec radiometric system was compared to conventional culture on solid medium for the detection of M. avium complex in 3,612 selected clinical specimens, mainly of extrapulmonary origin. Of a total number of 63 M. avium complex isolates, the Bactec system detected 58 (92%), compared to 37 (59%) for conventional culture. A much more rapid detection was attained with radiometric technique than with conventional culture. The mean detection time for the cultures positive with both methods was 7.1 and 28.3 days, respectively. The Bactec radiometric system achieves a rapid and significantly more sensitive detection and seems to be an excellent complement to conventional culture in the laboratory diagnosis of infections with the M. avium complex

  14. Rapid radiometric methods to detect and differentiate Mycobacterium tuberculosis/M. bovis from other mycobacterial species

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Hwangbo, C.C.; Silcox, V.; Good, R.C.; Snider, D.E. Jr.; Middlebrook, G.

    1984-01-01

    Rapid methods for the differentiation of Mycobacterium tuberculosis/M. bovis (TB complex) from other mycobacteria (MOTT bacilli) were developed and evaluated in a three-phase study. In the first phase, techniques for identification of Mycobacterium species were developed by using radiometric technology and BACTEC Middlebrook 7H12 liquid medium. Based on 14 CO 2 evolution, characteristic growth patterns were established for 13 commonly encountered mycobacterial species. Mycobacteria belonging to the TB complex were differentiated from other mycobacteria by cellular morphology and rate of 14 CO 2 evolution. For further differentiation, radiometric tests for niacin production and inhibition by Q-nitro-alpha-acetyl amino-beta-hydroxy-propiophenone (NAP) were developed. In the second phase, 100 coded specimens on Lowenstein-Jensen medium were identified as members of the TB complex, MOTT bacilli, bacteria other than mycobacteria, or ''no viable organisms'' within 3 to 12 (average 6.4) days of receipt from the Centers for Disease Control. Isolation and identification of mycobacteria from 20 simulated sputum specimens were carried out in phase III. Out of 20 sputum specimens, 16 contained culturable mycobacteria, and all of the positives were detected by the BACTEC method in an average of 7.3 days. The positive mycobacterial cultures were isolated and identified as TB complex or MOTT bacilli in an average of 12.8 days. The radiometric NAP test was found to be highly sensitive and specific for a rapid identification of TB complex, whereas the radiometric niacin test was found to have some inherent problems. Radiometric BACTEC and conventional methodologies were in complete agreement in Phase II as well as in Phase III

  15. Rapid detection and identification of pathogenic mycobacteria by combining radiometric and nucleic acid probe methods

    International Nuclear Information System (INIS)

    Ellner, P.D.; Kiehn, T.E.; Cammarata, R.; Hosmer, M.

    1988-01-01

    The combination of radiometric methodology (BACTEC 12B) and probe technology for recovery and identification of mycobacteria was studied in two large hospital laboratories. The sediment from vials with positive growth indices was tested with DNA probes specific for Mycobacterium tuberculosis, Mycobacterium avium, and Mycobacterium intracellulare. The sensitivity of the radiometric method and the specificity of the probes resulted in a marked reduction in the time to the final report. Biochemical testing could be eliminated on isolates giving a positive reaction with one of the probes. Some 176 isolates of M. tuberculosis, 110 of M. avium, and 5 of M. intracellulare were recovered. Two-thirds of these isolates were detected and identified within 2 weeks of inoculation and the remainder was detected by 4 weeks, a reduction of 5 to 7 weeks to the final report

  16. Simulation of Wake Vortex Radiometric Detection via Jet Exhaust Proxy

    Science.gov (United States)

    Daniels, Taumi S.

    2015-01-01

    This paper describes an analysis of the potential of an airborne hyperspectral imaging IR instrument to infer wake vortices via turbine jet exhaust as a proxy. The goal was to determine the requirements for an imaging spectrometer or radiometer to effectively detect the exhaust plume, and by inference, the location of the wake vortices. The effort examines the gas spectroscopy of the various major constituents of turbine jet exhaust and their contributions to the modeled detectable radiance. Initially, a theoretical analysis of wake vortex proxy detection by thermal radiation was realized in a series of simulations. The first stage used the SLAB plume model to simulate turbine jet exhaust plume characteristics, including exhaust gas transport dynamics and concentrations. The second stage used these plume characteristics as input to the Line By Line Radiative Transfer Model (LBLRTM) to simulate responses from both an imaging IR hyperspectral spectrometer or radiometer. These numerical simulations generated thermal imagery that was compared with previously reported wake vortex temperature data. This research is a continuation of an effort to specify the requirements for an imaging IR spectrometer or radiometer to make wake vortex measurements. Results of the two-stage simulation will be reported, including instrument specifications for wake vortex thermal detection. These results will be compared with previously reported results for IR imaging spectrometer performance.

  17. Microwave radiometric detection of thermal asymmetry of varicocele

    International Nuclear Information System (INIS)

    Felderman, T.P.; Shaeffer, J.; El-Mahdi, A.M.; Carr, K.L.; Stecker, J.F. Jr.

    1985-01-01

    Varicocele, a varicose enlargement of the veins in the spermatic cord, is found in 21-39% of men being evaluated for infertility. Thermometric detection of this condition was attempted by microwave radiometry as well as by contact thermometry using thermistor probes. The inguinal and scrotal regions of 44 male subject and inguinal regions of 11 female subjects were studied. Substantially different thermal patterns were obtained by thermistors (surface temperature) and microwave radiometry (subsurface temperature). There was a correlation between left scrotal varicocele and a temperature elevation of the left spermatic cord using microwave radiometry. This thermal defect appeared to be corrected following surgery

  18. Time course of radiometric detection of positive blood cultures in childhood

    International Nuclear Information System (INIS)

    Meadow, W.L.; Schwartz, I.K.

    1986-01-01

    We have determined the time course of radiometric detection of microbial growth in 2348 positive blood culture specimens obtained at Wyler Children's Hospital during a 5-year interval. Overall 72 and 88% of isolates were detected within 48 and 72 hours after sampling, respectively. For pathogenic organisms aerobic detection was generally more rapid and more inclusive than anaerobic detection. At 48 hours of incubation the detection of six potential pathogens (Salmonella sp., Haemophilus influenzae, Group D streptococci, Neisseria meningitidis, coagulase-negative staphylococci, Candida sp.) was significantly delayed compared with detection of other pathogenic organisms recovered from blood. At 72 hours of incubation the detection rates remained less than 95% for H. influenzae, Staphylococcus aureus, Klebsiella sp., coagulase-negative staphylococci, Group D streptococci and Candida sp. These data should assist clinical decisions regarding duration of antibiotic therapy for the presumptive diagnosis of bacteremia in children

  19. Time course of radiometric detection of positive blood cultures in childhood

    Energy Technology Data Exchange (ETDEWEB)

    Meadow, W.L.; Schwartz, I.K.

    1986-05-01

    We have determined the time course of radiometric detection of microbial growth in 2348 positive blood culture specimens obtained at Wyler Children's Hospital during a 5-year interval. Overall 72 and 88% of isolates were detected within 48 and 72 hours after sampling, respectively. For pathogenic organisms aerobic detection was generally more rapid and more inclusive than anaerobic detection. At 48 hours of incubation the detection of six potential pathogens (Salmonella sp., Haemophilus influenzae, Group D streptococci, Neisseria meningitidis, coagulase-negative staphylococci, Candida sp.) was significantly delayed compared with detection of other pathogenic organisms recovered from blood. At 72 hours of incubation the detection rates remained less than 95% for H. influenzae, Staphylococcus aureus, Klebsiella sp., coagulase-negative staphylococci, Group D streptococci and Candida sp. These data should assist clinical decisions regarding duration of antibiotic therapy for the presumptive diagnosis of bacteremia in children.

  20. A new relative radiometric consistency processing method for change detection based on wavelet transform and a low-pass filter

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The research purpose of this paper is to show the limitations of the existing radiometric normalization approaches and their disadvantages in change detection of artificial objects by comparing the existing approaches,on the basis of which a preprocessing approach to radiometric consistency,based on wavelet transform and a spatial low-pass filter,has been devised.This approach first separates the high frequency information and low frequency information by wavelet transform.Then,the processing of relative radiometric consistency based on a low-pass filter is conducted on the low frequency parts.After processing,an inverse wavelet transform is conducted to obtain the results image.The experimental results show that this approach can substantially reduce the influence on change detection of linear or nonlinear radiometric differences in multi-temporal images.

  1. Detection of group D and viridans streptococci in blood by radiometric methods

    International Nuclear Information System (INIS)

    Beckwith, D.G.

    1979-01-01

    A prospective study was conducted to evaluate the radiometric detection of group D and viridans streptococci in blood, using three media preparations, Bactec 6A and 6B isotonic media and 8B hypertonic medium. All enterococci tested were detected by the 6A and 6B media. However, the 6A medium failed to detect 76% of the Streptococcus bovis isolates and 57% of the viridans streptococci, whereas all S. bovis isolates and 95% of the viridans streptococci were detected with the 6B formulation. No improvement in detection was noted in comparing the 6B and the 8B hypertonic media. The importance of adequate detection of this group of organisms, especially in patients with endocarditis, is discussed

  2. Use of HPLC with flow-through radiometric detection for low level environmental analysis

    International Nuclear Information System (INIS)

    Mao, J.; Fackler, P.H.

    1992-01-01

    High Performance Liquid Chromatography with flow-through radiometric detection (HPLC-RAM) is increasingly becoming a standard analytical technique in pharmaceutical, agricultural and chemical industries for monitoring radiolabeled analytes. This paper focuses on the applications of this flow-through radiochromatographic technique for low level aquatic toxicology and environmental fate testing. Examples include parts per billion water, sediment/soil and fish tissue analyses using reverse phase as well as normal phase HPLC. The applications of both homogeneous (liquid) and heterogeneous (solid) flow cell scintillation counting are addressed. Compounds discussed are primarily pesticides and pharmaceuticals

  3. Laboratory experience with radiometric detection of bacteremia with three culture media

    International Nuclear Information System (INIS)

    Wicher, K.; Koscinski, D.

    1984-01-01

    In two long-term studies, the BACTEC radiometric system for detection of bacteremia was evaluated with three culture media each: (i) BACTEC media 6A (for aerobes) and 7B (for anaerobes) plus a thioglycolate medium and (ii) BACTEC media 6A, 7B, and 8A (hypertonic). In study 1, clinically significant isolates were identified in 1,873 (13.9%) of 13,432 blood cultures with all three media. The thioglycolate medium revealed 143 (1.1%) organisms not recovered from the 6A and 7B media. In study 2, isolates were identified in 1,135 (12.9%) of 8,759 cultures with all three media; 104 (1.2%) organisms were isolated only from the hypertonic medium. The increased yield of positive cultures in the three-medium system is likely due to the larger volume of blood cultured

  4. Radiometric immunosorbent assay for the detection of anti-hormone-binding protein antibodies

    International Nuclear Information System (INIS)

    Pierce, E.A.; Dame, M.C.; DeLuca, H.F.

    1986-01-01

    A radiometric immunosorbent assay (RISA) for the detection of monoclonal antibodies to hormone-binding proteins has been developed. The assay involves incubating hybridoma supernatants in microtiter wells that have been coated with goat anti-mouse IgG antibodies. Any mouse IgG in the test supernatant is thus specifically retained in the wells. Radioactive ligand-binding protein complexes are then incubated in the wells. The presence of anti-binding protein antibodies in the supernatant is indicated by specific retention of radioactive ligand-binding protein complexes in the wells. Crude antigen preparations, such as tissue homogenates, can be used to detect antibodies. The assay is capable of detecting antibody at concentrations 20 ng/ml (approx. 100 pM IgG). The RISA has been used successfully to screen for monoclonal antibodies to the intracellular receptor for 1,25-dihydroxyvitamin D 3 and should be useful for the detection of antibodies to ligand-binding proteins in general

  5. Comparison of radiometric and conventional culture systems in detecting Haemophilus influenzae type b bacteremia in rats

    International Nuclear Information System (INIS)

    Mitchell, M.J.; Zwahlen, A.; Elliott, H.L.; Ford, N.K.; Charache, F.P.; Moxon, E.R.

    1985-01-01

    To compare the efficiency of detecting Haemophilus influenzae type b bacteremia by the BACTEC radiometric system and a conventional Trypticase soy broth blood culture system, the authors developed an in vivo model of bacteremia in rats. After intravenous injection of 50 to 200 CFU into adult rats, there was a linear logarithmic increase in CFU per milliliter of rat blood during the first 10 h (r = 0.98), allowing accurate prediction of the level of bacteremia with time. Culture bottles were inoculated with 0.5 ml of blood obtained by cardiac puncture and processed as clinical samples in the microbiology laboratory with RS and conventional protocols. They found the following. (i) The first detection of bacteremia by RS was similar to that by TSB if a Gram stain of the TSB was done on day 1 and was superior if that smear was omitted (P less than 0.01). (ii) The detection times in both systems were comparable at different magnitudes of bacteremia (10(1) to 10(4) CFU/ml). (iii) Supplementation of inoculated bottles with 2 ml of sterile rat blood interfered with Gram stain detection in TSB but resulted in increased 14 CO 2 production in RS. (iv) No difference in detection time was found between RS and TSB for four different clinical isolates. These studies show that, in a biologically relevant model, the detection of positive blood cultures for H. influenzae type b by RS was comparable to or better than detection by TSB when blood was processed analogously to clinical specimens

  6. Detecting payload performance based on relative radiometric characteristic: case of the optical sensors

    Science.gov (United States)

    Han, Jie; Li, Shengyang; Zhang, Tao; Qin, Bangyong

    2016-10-01

    In this paper, we propose a novel algorithm for accurately estimating the degree of radiometric non-uniformity in remote sensing images. The algorithm was tested on high-quality images and heavily striping images, and quantitative analyses were conducted to evaluate the performance for each band by measuring the radiometric non-uniformity of the images. The results demonstrated that the proposed algorithm exhibits high accuracy and stability compared with traditional algorithms. The radiometric performance of TianGong-1 short-wave infrared images was calculated using this new method, and it was highly correlated with the solar angle, pitch angle and refrigerator thermal according to the Apriori algorithm. Based on these results, we have proposed a strategy for restricting increases in striping.

  7. Radiometric detection of metabolic activity of Paracoccidiodes brasiliensis and its susceptibility to amphotericin B and Diethylstilbestrol

    International Nuclear Information System (INIS)

    Camargo, E.E.; Sato, M.K.; Del Negro, G.M.B.; Lacaz, C.S.

    1987-01-01

    A radiometric assay system has been applied to study the metabolic activity and the effect of drugs (amphotericin B and diethylstilbestrol) on the fungus Paracoccidiodes brasiliensis ''in vitro''. The Y form of the yeast, grown in liquid Sabouraud medium was inoculated into sterile reaction vials containing the 6B aerobic medium along with 2.0μCi of 14 C-substrates. (M.A.C.) [pt

  8. MSFIA-LOV system for {sup 226}Ra isolation and pre-concentration from water samples previous radiometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez, Rogelio [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Borràs, Antoni [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Leal, Luz [Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Cerdà, Víctor [Department of Chemistry, University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Ferrer, Laura, E-mail: laura.ferrer@uib.es [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain)

    2016-03-10

    An automatic system based on multisyringe flow injection analysis (MSFIA) and lab-on-valve (LOV) flow techniques for separation and pre-concentration of {sup 226}Ra from drinking and natural water samples has been developed. The analytical protocol combines two different procedures: the Ra adsorption on MnO{sub 2} and the BaSO{sub 4} co-precipitation, achieving more selectivity especially in water samples with low radium levels. Radium is adsorbed on MnO{sub 2} deposited on macroporous of bead cellulose. Then, it is eluted with hydroxylamine to transform insoluble MnO{sub 2} to soluble Mn(II) thus freeing Ra, which is then coprecipitated with BaSO{sub 4}. The {sup 226}Ra can be directly detected in off-line mode using a low background proportional counter (LBPC) or through a liquid scintillation counter (LSC), after performing an on-line coprecipitate dissolution. Thus, the versatility of the proposed system allows the selection of the radiometric detection technique depending on the detector availability or the required response efficiency (sample number vs. response time and limit of detection). The MSFIA-LOV system improves the precision (1.7% RSD), and the extraction frequency (up to 3 h{sup −1}). Besides, it has been satisfactorily applied to different types of water matrices (tap, mineral, well and sea water). The {sup 226}Ra minimum detectable activities (LSC: 0.004 Bq L{sup −1}; LBPC: 0.02 Bq L{sup −1}) attained by this system allow to reach the guidance values proposed by the relevant international agencies e.g. WHO, EPA and EC. - Highlights: • Automatic, rapid and selective method for {sup 226}Ra extraction/pre-concentration from water. • MSFIA-LOV system performs a sample clean-up prior to {sup 226}Ra radiometric detection. • {sup 226}Ra sample preparation allows using two radiometric detectors (LBPC and LSC). • Environmental levels of {sup 226}Ra are easily quantified. • High sensitivity and selectivity are achieved, reaching the

  9. Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia

    International Nuclear Information System (INIS)

    Weinstein, M.P.; Mirrett, S.; Reller, L.B.

    1988-01-01

    The Oxoid Signal blood culture system is a newly described, innovative method for visually detecting growth of microorganisms. We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilus species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi

  10. Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in High-Voltage Equipment

    Science.gov (United States)

    Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.

    2018-03-01

    Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.

  11. Radiometric dating

    International Nuclear Information System (INIS)

    Das, N.R.

    2017-01-01

    Since the discovery of natural radioactivity in uranium, in the last decade of the nineteenth century, the nuclear property of radioactive decay of radionuclides at immutable rates has been effectively utilized in dating of varieties of naturally occurring geological matrices and the organisms which constantly replenish their "1"4C supply through respiration when alive on earth. During the period, applications of radiometric dating techniques have been extensively diversified and have enabled the geologists to indicate the absolute time scales of geological formations and the evolution of the solar system, the earth, meteorites, lunar rocks, etc. and the archaeologists to record the facts of history of several important events like dinosaur era, Iceman, the Shroud in Turin and many other ancient artefacts. In the development of dating methods, varieties of naturally occurring radio-isotopic systems with favorable half-lives ranging from about 10 years to over 100 billion years have been used as radiometric clocks. (author)

  12. Radiometric analyzer

    International Nuclear Information System (INIS)

    Arima, S.; Oda, M.; Miyashita, K.; Takada, M.

    1977-01-01

    A radiometric analyzer for measuring the characteristic values of a sample by radiation includes a humer of radiation measuring subsystems having different ratios of sensitivities to the elements of the sample and linearizing circuits having inverse function characteristics of calibration functions which correspond to the radiation measuring subsystems. A weighing adder operates a desirable linear combination of the outputs of the linearizing circuits. Operators for operating between two or more different linear combinations are included

  13. A method for unsupervised change detection and automatic radiometric normalization in multispectral data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Canty, Morton John

    2011-01-01

    Based on canonical correlation analysis the iteratively re-weighted multivariate alteration detection (MAD) method is used to successfully perform unsupervised change detection in bi-temporal Landsat ETM+ images covering an area with villages, woods, agricultural fields and open pit mines in North...... to carry out the analyses is available from the authors' websites....

  14. Safeguards applications of far infrared radiometric techniques for the detection of contraband

    Energy Technology Data Exchange (ETDEWEB)

    Hodges, D.T.; Reber, E.E.; Foote, F.B.; Schellenbaum, R.L.

    1980-02-01

    A new safeguards system under development employs radiometers in the 100 to 300 GHz spectral band to detect contraband, including shielding materials (used to attenuate the gamma ray emissions from nuclear materials), weapons, or explosives covertly concealed on personnel. Clothing is highly transparent at these frequencies and imaging techniques can detect contraband by its emissivity and reflectivity differences relative to human tissues. Experimental data are presented and sample images are used as a basis to discuss system advantages and limitations.

  15. Safeguards applications of far infrared radiometric techniques for the detection of contraband

    International Nuclear Information System (INIS)

    Hodges, D.T.; Reber, E.E.; Foote, F.B.; Schellenbaum, R.L.

    1980-02-01

    A new safeguards system under development employs radiometers in the 100 to 300 GHz spectral band to detect contraband, including shielding materials (used to attenuate the gamma ray emissions from nuclear materials), weapons, or explosives covertly concealed on personnel. Clothing is highly transparent at these frequencies and imaging techniques can detect contraband by its emissivity and reflectivity differences relative to human tissues. Experimental data are presented and sample images are used as a basis to discuss system advantages and limitations

  16. Effects of Landsat 5 Thematic Mapper and Landsat 7 Enhanced Thematic Mapper plus radiometric and geometric calibrations and corrections on landscape characterization

    Science.gov (United States)

    Vogelmann, James E.; Helder, Dennis; Morfitt, Ron; Choate, Michael J.; Merchant, James W.; Bulley, Henry

    2001-01-01

    The Thematic Mapper (TM) instruments onboard Landsats 4 and 5 provide high-quality imagery appropriate for many different applications, including land cover mapping, landscape ecology, and change detection. Precise calibration was considered to be critical to the success of the Landsat 7 mission and, thus, issues of calibration were given high priority during the development of the Enhanced Thematic Mapper Plus (ETM+). Data sets from the Landsat 5 TM are not routinely corrected for a number of radiometric and geometric artifacts, including memory effect, gain/bias, and interfocal plane misalignment. In the current investigation, the effects of correcting vs. not correcting these factors were investigated for several applications. Gain/bias calibrations were found to have a greater impact on most applications than did memory effect calibrations. Correcting interfocal plane offsets was found to have a moderate effect on applications. On June 2, 1999, Landsats 5 and 7 data were acquired nearly simultaneously over a study site in the Niobrara, NE area. Field radiometer data acquired at that site were used to facilitate crosscalibrations of Landsats 5 and 7 data. Current findings and results from previous investigations indicate that the internal calibrator of Landsat 5 TM tracked instrument gain well until 1988. After this, the internal calibrator diverged from the data derived from vicarious calibrations. Results from this study also indicate very good agreement between prelaunch measurements and vicarious calibration data for all Landsat 7 reflective bands except Band 4. Values are within about 3.5% of each other, except for Band 4, which differs by 10%. Coefficient of variation (CV) values derived from selected targets in the imagery were also analyzed. The Niobrara Landsat 7 imagery was found to have lower CV values than Landsat 5 data, implying that lower levels of noise characterize Landsat 7 data than current Landsat 5 data. It was also found that following

  17. Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system

    International Nuclear Information System (INIS)

    Weinstein, M.P.; Mirrett, S.; Reimer, L.G.; Reller, L.B.

    1989-01-01

    In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia. To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive cultures relative to the BACTEC radiometric system, we agitated all Oxoid bottles during the first 24 to 48 h of incubation and performed aerobic and anaerobic subcultures of all Oxoid bottles negative after 7 days of incubation. These modifications improved the overall performance of the Oxoid system, particularly with regard to the yield of streptococci, members of the family Enterobacteriaceae, and Haemophilus, Neisseria, and Acinetobacter spp. The speed of detecting positive cultures also was improved, especially within the first 24 h of incubation. However, the BACTEC system still detected more positive cultures (P less than 0.005), especially of obligate aerobes such as Pseudomonas aeruginosa (P less than 0.05) and yeasts (P less than 0.005). The BACTEC system also detected positive cultures earlier than the Oxoid system (e.g., at 24 h of incubation, 70.5% of BACTEC positive cultures detected versus 62.1% of Oxoid positive cultures detected). Further modifications of the Oxoid system which might include a revised medium, additional processing modifications, altered headspace atmosphere, or a complementary second broth medium should be considered, since the system is attractive in concept and is easy to use in the clinical laboratory

  18. Radiometric Normalization of Temporal Images Combining Automatic Detection of Pseudo-Invariant Features from the Distance and Similarity Spectral Measures, Density Scatterplot Analysis, and Robust Regression

    Directory of Open Access Journals (Sweden)

    Ana Paula Ferreira de Carvalho

    2013-05-01

    Full Text Available Radiometric precision is difficult to maintain in orbital images due to several factors (atmospheric conditions, Earth-sun distance, detector calibration, illumination, and viewing angles. These unwanted effects must be removed for radiometric consistency among temporal images, leaving only land-leaving radiances, for optimum change detection. A variety of relative radiometric correction techniques were developed for the correction or rectification of images, of the same area, through use of reference targets whose reflectance do not change significantly with time, i.e., pseudo-invariant features (PIFs. This paper proposes a new technique for radiometric normalization, which uses three sequential methods for an accurate PIFs selection: spectral measures of temporal data (spectral distance and similarity, density scatter plot analysis (ridge method, and robust regression. The spectral measures used are the spectral angle (Spectral Angle Mapper, SAM, spectral correlation (Spectral Correlation Mapper, SCM, and Euclidean distance. The spectral measures between the spectra at times t1 and t2 and are calculated for each pixel. After classification using threshold values, it is possible to define points with the same spectral behavior, including PIFs. The distance and similarity measures are complementary and can be calculated together. The ridge method uses a density plot generated from images acquired on different dates for the selection of PIFs. In a density plot, the invariant pixels, together, form a high-density ridge, while variant pixels (clouds and land cover changes are spread, having low density, facilitating its exclusion. Finally, the selected PIFs are subjected to a robust regression (M-estimate between pairs of temporal bands for the detection and elimination of outliers, and to obtain the optimal linear equation for a given set of target points. The robust regression is insensitive to outliers, i.e., observation that appears to deviate

  19. Environmental radiometric

    International Nuclear Information System (INIS)

    Gaeta C, R.

    1986-07-01

    This document stresses the importance of measuring the radioactivity of the environment in order to evaluate the radiological exposure of the population. The document emphasizes the necessity of detecting very low levels of radioactivity and the difficulties that it implies. The various components of its basis and the means for its reduction are mentioned. Information on the instruments required to identify and quantify the activities of the different radionuclides is given

  20. Evaluation of relative radiometric correction techniques on Landsat 8 OLI sensor data

    Science.gov (United States)

    Novelli, Antonio; Caradonna, Grazia; Tarantino, Eufemia

    2016-08-01

    The quality of information derived from processed remotely sensed data may depend upon many factors, mostly related to the extent data acquisition is influenced by atmospheric conditions, topographic effects, sun angle and so on. The goal of radiometric corrections is to reduce such effects in order enhance the performance of change detection analysis. There are two approaches to radiometric correction: absolute and relative calibrations. Due to the large amount of free data products available, absolute radiometric calibration techniques may be time consuming and financially expensive because of the necessary inputs for absolute calibration models (often these data are not available and can be difficult to obtain). The relative approach to radiometric correction, known as relative radiometric normalization, is preferred with some research topics because no in situ ancillary data, at the time of satellite overpasses, are required. In this study we evaluated three well known relative radiometric correction techniques using two Landsat 8 - OLI scenes over a subset area of the Apulia Region (southern Italy): the IR-MAD (Iteratively Reweighted Multivariate Alteration Detection), the HM (Histogram Matching) and the DOS (Dark Object Subtraction). IR-MAD results were statistically assessed within a territory with an extremely heterogeneous landscape and all computations performed in a Matlab environment. The panchromatic and thermal bands were excluded from the comparisons.

  1. Radionuclide Sensors for Environmental Monitoring: From Flow Injection Solid-Phase Absorptiometry to Equilibration-Based Preconcentrating Minicolumn Sensors with Radiometric Detection

    International Nuclear Information System (INIS)

    Grate, Jay W.; Egorov, Oleg B.; O'Hara, Matthew J.; Devol, Timothy A.

    2008-01-01

    The development of in situ sensors for ultratrace detection applications in process control and environmental monitoring remains a significant challenge. Such sensors must meet difficult detection limit requirements while selectively detecting the analyte of interest in complex or otherwise challenging sample matrixes. Nowhere are these requirements more daunting than in the field of radionuclide sensing. The detection limit requirements can be extremely low. Nevertheless, a promising approach to radionuclide sensing based on preconcentrating minicolumn sensors has been developed. In addition, a method of operating such sensors, which we call equilibration-based sensing, has been developed that provides substantial preconcentration and a signal that is proportional to analyte concentration, while eliminating the need for reagents to regenerate the sorbent medium following each measurement. While this equilibration-based sensing method was developed for radionuclide sensing, it can be applied to nonradioactive species as well, given a suitable on-column detection system. By replacing costly sampling and laboratory analysis procedures, in situ sensors could have a significant impact on monitoring and long term stewardship applications. The aim of this review is to cover radionuclide sensors that combine some form of selective sorption with a radiometric detection method, and, as a primary aim, to comprehensively review preconcentrating minicolumn sensors for radionuclide detection. As a secondary aim, we will cover radionuclide sensors that combine sorption and scintillation in formats other than minicolumn sensors. We are particularly concerned with the detection of alpha- and beta-emitting radionuclides, which present particular challenges for measurements in liquid media

  2. Loss of surface horizon of an irrigated soil detected by radiometric images of normalized difference vegetation index.

    Science.gov (United States)

    Fabian Sallesses, Leonardo; Aparicio, Virginia Carolina; Costa, Jose Luis

    2017-04-01

    The use of the soil in the Humid Pampa of Argentina has changed since the mid-1990s from agricultural-livestock production (that included pastures with direct grazing) to a purely agricultural production. Also, in recent years the area under irrigation by central pivot has been increased to 150%. The waters used for irrigation are sodium carbonates. The combination of irrigation and rain increases the sodium absorption ratio of soil (SARs), consequently raising the clay dispersion and reducing infiltration. This implies an increased risk of soil loss. A reduction in the development of white clover crop (Trifolium repens L.) was observed at an irrigation plot during 2015 campaign. The clover was planted in order to reduce the impact of two maize (Zea mays L.) campaigns under irrigation, which had increased soil SAR and deteriorated soil structure. SPOT-5 radiometric normalized difference vegetation index (NDVI) images were used to determine two zones of high and low production. In each zone, four random points were selected for further geo-referenced field sampling. Two geo-referenced measures of effective depth and surface soil sampling were carried out in each point. Texture of soil samples was determined by Pipette Method of Sedimentation Analysis. Data exploratory analysis showed that low production zone had a media effective depth = 80 cm and silty clay loam texture, while high production zone had a media effective depth > 140 cm and silt loam texture. The texture class of the low production zone did not correspond to prior soil studies carried out by the INTA (National Institute of Agricultural Technology), which showed that those soil textures were silt loam at surface and silty clay loam at sub-surface. The loss of the A horizon is proposed as a possible explanation, but further research is required. Besides, the need of a soil cartography actualization, which integrates new satellite imaging technologies and geo-referenced measurements with soil sensors is

  3. Automated radioanalytical system incorporating microwave-assisted sample preparation, chemical separation, and online radiometric detection for the monitoring of total 99Tc in nuclear waste processing streams.

    Science.gov (United States)

    Egorov, Oleg B; O'Hara, Matthew J; Grate, Jay W

    2012-04-03

    An automated fluidic instrument is described that rapidly determines the total (99)Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the (99)Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of (99)Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of (99)Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

  4. Broadband Radiometric LED Measurements

    OpenAIRE

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(��) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irr...

  5. Rapid radiometric detection of microbial contamination using 14C-glucose and standard liquid scintillation counting system

    International Nuclear Information System (INIS)

    Joshi, S.H.; Kamble, S.B.; Pilkhwal, N.S.; Ramamoorthy, N.

    1998-01-01

    A simple and rapid method for detection of microbial contamination based on quantitation of 14 CO 2 released during metabolism of 14 C-Glucose by microorganisms is reported. Liquid scintillation counting system (LSCS) with a modified sample preparation method was utilised. The scintillator was impregnated on Whatman-1 paper on which 14 CO 2 evolved during metabolism could be absorbed. The important parameters of counting such as efficiency, position sensitivity and geometry as well as effect of NaOH quantity and of microbial load on detection period were studied. The efficiency of radioactivity assay was 18±2.8 %. Contamination of the order of 5-10 organism/ml of product could be detected in about 24 hours. (author)

  6. Discrepancy between growth of Coccidioides immitis in bacterial blood culture media and a radiometric growth index

    International Nuclear Information System (INIS)

    Ampel, N.M.; Wieden, M.A.

    1988-01-01

    Spherules of Coccidioides immitis grew readily after inoculation in vented trypticase soy broth, biphasic brain heart infusion media, and aerobic tryptic soy broth bottles used in a radiometric system (BACTEC). However, visible growth was not accompanied by a significant radiometric growth index. Growth of C. immitis can be visually detected in routine bacterial blood culture media while the radiometric growth index remains negative

  7. Broadband radiometric LED measurements

    Science.gov (United States)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  8. Radiometric well logging instruments

    International Nuclear Information System (INIS)

    Davydov, A.V.

    1975-01-01

    The technical properties of well instruments for radioactive logging used in the radiometric logging complexes PKS-1000-1 (''Sond-1'') and PRKS-2 (''Vitok-2'') are described. The main features of the electric circuit of the measuring channels are given

  9. Automation of radiometric testing

    International Nuclear Information System (INIS)

    Chekalin, A.S.; Temnik, A.K.; Butakova, G.E.; Goncharov, V.I.

    1983-01-01

    The main prerequisites for creation of automatic systems of radiometric testing as the means to increase the testing objectivity and quality have been considered, principles of their design being developed. The operating system is described for testing complex configuration products using RD-10R gamma flow detector as a sensor of initial information

  10. RADIOMETRIC BLOCK ADJUSMENT AND DIGITAL RADIOMETRIC MODEL GENERATION

    Directory of Open Access Journals (Sweden)

    A. Pros

    2013-05-01

    Full Text Available In this paper we present a radiometric block adjustment method that is related to geometric block adjustment and to the concept of a terrain Digital Radiometric Model (DRM as a complement to the terrain digital elevation and surface models. A DRM, in our concept, is a function that for each ground point returns a reflectance value and a Bidirectional Reflectance Distribution Function (BRDF. In a similar way to the terrain geometric reconstruction procedure, given an image block of some terrain area, we split the DRM generation in two phases: radiometric block adjustment and DRM generation. In the paper we concentrate on the radiometric block adjustment step, but we also describe a preliminary DRM generator. In the block adjustment step, after a radiometric pre-calibraton step, local atmosphere radiative transfer parameters, and ground reflectances and BRDFs at the radiometric tie points are estimated. This radiometric block adjustment is based on atmospheric radiative transfer (ART models, pre-selected BRDF models and radiometric ground control points. The proposed concept is implemented and applied in an experimental campaign, and the obtained results are presented. The DRM and orthophoto mosaics are generated showing no radiometric differences at the seam lines.

  11. Gamma radiometric survey of Jamaica

    International Nuclear Information System (INIS)

    Lalor, G.C.; Robotham, H.; Miller, J.M.; Simpson, P.R.

    1989-01-01

    The results of a total gamma radiometric survey of Jamaica, carried out with car-borne instrumentation, are presented and the data compared with the contents of potassium, thorium and uranium in rocks and in surface (soil, stream-sediment, pan concentrate and water) samples obtained at six sites selected to be representative of the principal rock types and surface environments of Jamaica. The work formed part of an orientation study for a regional geochemical survey of the CARICOM countries of the Caribbean. The initial results indicate that enhanced gamma activity is correlated with enrichment in uranium and thorium, but not potassium, in terra rossa soils and/or bauxite deposits in limestone. Elsewhere, gamma levels are increased on the Above Rocks Cretaceous basement Inlier, where they correlate generally with the presence of volcanogenic sediments and a granodiorite intrusion. The lowest radioactivity was recorded in the vicinity of ultrabasic rocks in the Blue Mountains Inlier. (author)

  12. Radiometric diagnosis of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Laszlo, A.

    1986-01-01

    The results of this study confirm that rapid radiometric diagnostic tests such as the NAP selective inhibition test for the M. tuberculosis complex followed by the radiometric drug susceptibility tests are extremely reliable and compare favourably with conventional methodologies. This study also shows that referred cultures growing on solid medium can be processed by radiometric procedures without prior subculture. This circumstance by itself shortens the time needed for reporting. (Auth.)

  13. KERNEL MAD ALGORITHM FOR RELATIVE RADIOMETRIC NORMALIZATION

    Directory of Open Access Journals (Sweden)

    Y. Bai

    2016-06-01

    Full Text Available The multivariate alteration detection (MAD algorithm is commonly used in relative radiometric normalization. This algorithm is based on linear canonical correlation analysis (CCA which can analyze only linear relationships among bands. Therefore, we first introduce a new version of MAD in this study based on the established method known as kernel canonical correlation analysis (KCCA. The proposed method effectively extracts the non-linear and complex relationships among variables. We then conduct relative radiometric normalization experiments on both the linear CCA and KCCA version of the MAD algorithm with the use of Landsat-8 data of Beijing, China, and Gaofen-1(GF-1 data derived from South China. Finally, we analyze the difference between the two methods. Results show that the KCCA-based MAD can be satisfactorily applied to relative radiometric normalization, this algorithm can well describe the nonlinear relationship between multi-temporal images. This work is the first attempt to apply a KCCA-based MAD algorithm to relative radiometric normalization.

  14. Sterility test by radiometric technique

    International Nuclear Information System (INIS)

    Faruq, Muhammad

    1980-01-01

    Sterility test of pharmaceuticals can be carried out by the application of pharmacopoeia and radiometric technique. In Indonesia the application of pharmacopoeia technique is carried out through liquid germination for aerobacteria and for fungus and yeast. Radiometric technique is applied to autotrop and heterotrop bacteria. (SMN)

  15. Fusion and normalization to enhance anomaly detection

    Science.gov (United States)

    Mayer, R.; Atkinson, G.; Antoniades, J.; Baumback, M.; Chester, D.; Edwards, J.; Goldstein, A.; Haas, D.; Henderson, S.; Liu, L.

    2009-05-01

    This study examines normalizing the imagery and the optimization metrics to enhance anomaly and change detection, respectively. The RX algorithm, the standard anomaly detector for hyperspectral imagery, more successfully extracts bright rather than dark man-made objects when applied to visible hyperspectral imagery. However, normalizing the imagery prior to applying the anomaly detector can help detect some of the problematic dark objects, but can also miss some bright objects. This study jointly fuses images of RX applied to normalized and unnormalized imagery and has a single decision surface. The technique was tested using imagery of commercial vehicles in urban environment gathered by a hyperspectral visible/near IR sensor mounted in an airborne platform. Combining detections first requires converting the detector output to a target probability. The observed anomaly detections were fitted with a linear combination of chi square distributions and these weights were used to help compute the target probability. Receiver Operator Characteristic (ROC) quantitatively assessed the target detection performance. The target detection performance is highly variable depending on the relative number of candidate bright and dark targets and false alarms and controlled in this study by using vegetation and street line masks. The joint Boolean OR and AND operations also generate variable performance depending on the scene. The joint SUM operation provides a reasonable compromise between OR and AND operations and has good target detection performance. In addition, new transforms based on normalizing correlation coefficient and least squares generate new transforms related to canonical correlation analysis (CCA) and a normalized image regression (NIR). Transforms based on CCA and NIR performed better than the standard approaches. Only RX detection of the unnormalized of the difference imagery in change detection provides adequate change detection performance.

  16. Radiometric report for a blast furnace tracing with radioactive isotopes

    International Nuclear Information System (INIS)

    Tanase, G.; Tanase, M.

    1995-01-01

    One of the methods to monitor refractory wall of blast furnace is its tracing with radioactive isotopes. The tracer isotope can be detected by two ways: the external dosimetric measurement at the armour of the blast furnace and/or the radiometric measurement of the iron sample charge by charge. Any change in radiometric situation of tracer radioisotope is recorded in a radiometric report. This paper presents an original concept of radiometric report based upon PARADOX and CORELDRAW soft kits. Their advantage are: quick and easy changes, easy recording of current radioactivity of tracer isotope, short history of changes, visual mapping of the tracer isotope and others. In this way we monitored 6 blast furnaces and more than 180 radioactive sources

  17. Seeing Objects as Faces Enhances Object Detection.

    Science.gov (United States)

    Takahashi, Kohske; Watanabe, Katsumi

    2015-10-01

    The face is a special visual stimulus. Both bottom-up processes for low-level facial features and top-down modulation by face expectations contribute to the advantages of face perception. However, it is hard to dissociate the top-down factors from the bottom-up processes, since facial stimuli mandatorily lead to face awareness. In the present study, using the face pareidolia phenomenon, we demonstrated that face awareness, namely seeing an object as a face, enhances object detection performance. In face pareidolia, some people see a visual stimulus, for example, three dots arranged in V shape, as a face, while others do not. This phenomenon allows us to investigate the effect of face awareness leaving the stimulus per se unchanged. Participants were asked to detect a face target or a triangle target. While target per se was identical between the two tasks, the detection sensitivity was higher when the participants recognized the target as a face. This was the case irrespective of the stimulus eccentricity or the vertical orientation of the stimulus. These results demonstrate that seeing an object as a face facilitates object detection via top-down modulation. The advantages of face perception are, therefore, at least partly, due to face awareness.

  18. Seeing Objects as Faces Enhances Object Detection

    Directory of Open Access Journals (Sweden)

    Kohske Takahashi

    2015-09-01

    Full Text Available The face is a special visual stimulus. Both bottom-up processes for low-level facial features and top-down modulation by face expectations contribute to the advantages of face perception. However, it is hard to dissociate the top-down factors from the bottom-up processes, since facial stimuli mandatorily lead to face awareness. In the present study, using the face pareidolia phenomenon, we demonstrated that face awareness, namely seeing an object as a face, enhances object detection performance. In face pareidolia, some people see a visual stimulus, for example, three dots arranged in V shape, as a face, while others do not. This phenomenon allows us to investigate the effect of face awareness leaving the stimulus per se unchanged. Participants were asked to detect a face target or a triangle target. While target per se was identical between the two tasks, the detection sensitivity was higher when the participants recognized the target as a face. This was the case irrespective of the stimulus eccentricity or the vertical orientation of the stimulus. These results demonstrate that seeing an object as a face facilitates object detection via top-down modulation. The advantages of face perception are, therefore, at least partly, due to face awareness.

  19. Radiometric enrichment of nonradioactive ores

    International Nuclear Information System (INIS)

    Mokrousov, V.A.; Lileev, V.A.

    1979-01-01

    Considered are the methods of mineral enrichment based on the use of the radioation of various types. The physical essence of enrichment processes is presented, their classification is given. Described are the ore properties influencing the efficiency of radiometric enrichment, methods of the properties study and estimation of ore enrichment. New possibilities opened by radiometric enrichment in the technology of primary processing of mineral raw materials are elucidated. A considerable attention is paid to the main and auxiliary equipment for radiometric enrichment. The foundations of the safety engineering are presented in a brief form. Presented are also results of investigations and practical works in the field of enrichment of ores of non-ferrous, ferrous and non-metallic minerals with the help of radiometric methods

  20. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration

    Directory of Open Access Journals (Sweden)

    Alireza G. Kashani

    2015-11-01

    Full Text Available In addition to precise 3D coordinates, most light detection and ranging (LIDAR systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  1. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration.

    Science.gov (United States)

    Kashani, Alireza G; Olsen, Michael J; Parrish, Christopher E; Wilson, Nicholas

    2015-11-06

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record "intensity", loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of "normalization", "correction", or "calibration" techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  2. Plasmonically enhanced thermomechanical detection of infrared radiation.

    Science.gov (United States)

    Yi, Fei; Zhu, Hai; Reed, Jason C; Cubukcu, Ertugrul

    2013-04-10

    Nanoplasmonics has been an attractive area of research due to its ability to localize and manipulate freely propagating radiation on the nanometer scale for strong light-matter interactions. Meanwhile, nanomechanics has set records in the sensing of mass, force, and displacement. In this work, we report efficient coupling between infrared radiation and nanomechanical resonators through nanoantenna enhanced thermoplasmonic effects. Using efficient conversion of electromagnetic energy to mechanical energy in this plasmo-thermomechanical platform with a nanoslot plasmonic absorber integrated directly on a nanobeam mechanical resonator, we demonstrate room-temperature detection of nanowatt level power fluctuations in infrared radiation. We expect our approach, which combines nanoplasmonics with nanomechanical resonators, to lead to optically controlled nanomechanical systems enabling unprecedented functionality in biomolecular and toxic gas sensing and on-chip mass spectroscopy.

  3. Radiometric surveys in underground environment

    Science.gov (United States)

    Bochiolo, Massimo; Chiozzi, Paolo; Verdoya, Massimo; Pasquale, Vincenzo

    2010-05-01

    Due to their ability to travel through the air for several metres, gamma-rays emitted from natural radioactive elements can be successfully used in surveys carried out both with airborne and ground equipments. Besides the concentration of the radio-elements contained in rocks and soils and the intrinsic characteristics of the gamma-ray detector, the detected count rate depends on the solid angle around the spectrometer. On a flat outcrop, ground spectrometry detects the radiation ideally produced by a cylindrical mass of rock of about two metres in diameter and thickness of about half a meter. Under these geometrical conditions, the natural radioactivity can be easily evaluated. With operating conditions different from the standard ones, such as at the edge of an escarpment, the count rate halves because of the missing material, whereas in the vicinity of a rock wall the count rate will increase. In underground environment, the recorded count rate may even double and the in situ assessment of the concentration of radio-elements may be rather difficult, even if the ratios between the different radio-elements may not be affected. We tested the applicability of gamma-ray spectrometry for rapid assessment of the potential hazard levels related to radon and radiation dose rate in underground environment. A mine shaft, located in a zone of uranium enrichment in Liguria (Italy), has been investigated. A preliminary ground radiometric survey was carried out to define the extent of the ore deposit. Then, the radiometric investigation was focussed on the mine shaft. Due to rock mass above the shaft vault, the background gamma radiation can be considered of negligible influence on measurements. In underground surveys, besides deviations from a flat geometry, factors controlling radon exhalation, emanation and stagnation, such as fractures, water leakage and the presence of ventilation, should be carefully examined. We attempted to evaluate these control factors and collected

  4. Sonar Image Enhancements for Improved Detection of Sea Mines

    DEFF Research Database (Denmark)

    Jespersen, Karl; Sørensen, Helge Bjarup Dissing; Zerr, Benoit

    1999-01-01

    In this paper, five methods for enhancing sonar images prior to automatic detection of sea mines are investigated. Two of the methods have previously been published in connection with detection systems and serve as reference. The three new enhancement approaches are variance stabilizing log...... transform, nonlinear filtering, and pixel averaging for speckle reduction. The effect of the enhancement step is tested by using the full prcessing chain i.e. enhancement, detection and thresholding to determine the number of detections and false alarms. Substituting different enhancement algorithms...... in the processing chain gives a precise measure of the performance of the enhancement stage. The test is performed using a sonar image database with images ranging from very simple to very complex. The result of the comparison indicates that the new enhancement approaches improve the detection performance....

  5. Itinerant radiometric laboratory (IRL-76)

    International Nuclear Information System (INIS)

    Dolgirev, E.I.; Domaratskij, V.P.; Kostikov, Yu.I.

    1978-01-01

    A mobile radiometric laboratory for routine radiation monitoring of the environment, personnel, and population is described. As compared to the previous models, this one incorporates a number of new features and is more informative and versatile. The design and main technical and operating characteristics of the laboratory are detailed

  6. Space Object Radiometric Modeling for Hardbody Optical Signature Database Generation

    Science.gov (United States)

    2009-09-01

    Introduction This presentation summarizes recent activity in monitoring spacecraft health status using passive remote optical nonimaging ...Approved for public release; distribution is unlimited. Space Object Radiometric Modeling for Hardbody Optical Signature Database Generation...It is beneficial to the observer/analyst to understand the fundamental optical signature variability associated with these detection and

  7. Enhanced leak detection risk model development

    Energy Technology Data Exchange (ETDEWEB)

    Harron, Lorna; Barlow, Rick; Farquhar, Ted [Enbridge Pipelines Inc., Edmonton, Alberta (Canada)

    2010-07-01

    Increasing concerns and attention to pipeline safety have engaged pipeline companies and regulatory agencies to extend their approaches to pipeline integrity. The implementation of High Consequence Areas (HCAs) has especially had an impact on the development of integrity management protocols (IMPs) for pipelines. These IMPs can require that a risk based assessment of integrity issues be applied to specific HCA risk factors. This paper addresses the development of an operational risk assessment approach for pipeline leak detection requirements for HCAs. A detailed risk assessment algorithm that includes 25 risk variables and 28 consequence variables was developed for application to all HCA areas. This paper describes the consultative process that was used to workshop the development of this algorithm. Included in this description is how the process addressed various methods of leak detection across a wide variety of pipelines. The paper also looks at development challenges and future steps in applying operation risk assessment techniques to mainline leak detection risk management.

  8. Microfluidic immunomagnetic separation for enhanced bacterial detection

    DEFF Research Database (Denmark)

    Hoyland, James; Kunstmann-Olsen, Casper; Ahmed, Shakil

    A combined lab-on-a-chip approach combining immunomagnetic separation (IMS) and flow cytometry was developed for the enrichment and detection of salmonella contamination in food samples. Immunomagnetic beads were immobilized in chips consisting of long fractal meanders while contaminated samples...... to obtain maximum capturing efficiency. The effects of channel volume, path length and number of bends of microfluidic chip on IMS efficiency were also determined....

  9. Radiometric weighing devices. Part 1 and 2

    International Nuclear Information System (INIS)

    Glaeser, M.

    1985-01-01

    Proceeding from the physical and mathematical fundamentals and from the types of radiometric weighing devices presently available, the radiation protection problems arising from the application of radiometric gages in industry and agriculture are discussed. Nuclear weighing devices have been found to be effective from economic point of view but in some cases gravimetric conveyor weighers are indispensable. Information and guidance is given especially for users of radiometric weighing devices. 91 refs., 69 figs., and 8 tabs

  10. Spectrometric devices of itinerant radiometric laboratory

    International Nuclear Information System (INIS)

    Dolgirev, E.I.; Moroz, G.L.; Shchedrin, D.A.

    1978-01-01

    Scintillation gamma-spectrometer is described designed for mobile radiometric laboratory for individual monitoring of internal γ-radiation of members of the general population and service personnel as well as for analysis of the isotopic composition of radiocontaminants in the environment. Description and technical features of device are given. The detection unit consists of detectors made on the basis of NaI(Tl) monocrystals 63 x 63 mm in size. The unit permits measurement of various levels of gamma-emitting nuclides throughout the body and in the thyroid and lungs of man. Provision is made for measuring samples with high specific activities (more than 10 -5 Cu/g) and for examining individuals having high levels of incorporated radionuclides

  11. Incidentally Detected Enhancing Breast Lesions on Chest Computed Tomography

    International Nuclear Information System (INIS)

    Lin, Wen Chiung; Hsu, Hsian He; Yu, Jyh Cherng; Hsu, Giu Cheng; Yu, Cheng Ping; Chang, Tsun Hou; Huang, Guo Shu; Li, Chao Shiang

    2011-01-01

    To evaluate the nature and imaging appearance of incidental enhancing breast lesions detected on a routine contrast-enhanced chest CT. Twenty-three patients with incidental enhancing breast lesions on contrast-enhanced chest CT were retrospectively reviewed. The breast lesions were reviewed by unenhanced and enhanced CT, and evaluated by observing the shapes, margins, enhancement patterns and backgrounds of breast lesions. A histopathologic diagnosis or long-term follow-up served as reference standard. Sixteen (70%) patients had malignant breast lesions and seven (30%) had benign lesions. In 10 patients, the breast lesions were exclusively detected on contrast-enhanced CT. Using unenhanced CT, breast lesions with fi broglandular backgrounds were prone to be obscured (p < 0.001). Incidental primary breast cancer showed an non-significant trend of a higher percentage irregular margin (p = 0.056). All of the four incidental breast lesions with non-mass-like enhancement were proven to be malignant. Routine contrast-enhanced chest CT can reveal sufficient details to allow for the detection of unsuspected breast lesions, in which some cases may be proven as malignant. An irregular margin of incidental enhancing breast lesion can be considered a suggestive sign of malignancy

  12. Nanostructured surface enhanced Raman scattering substrates for explosives detection

    DEFF Research Database (Denmark)

    Schmidt, Michael Stenbaek; Olsen, Jesper Kenneth; Boisen, Anja

    2010-01-01

    Here we present a method for trace detection of explosives in the gas phase using novel surface enhanced Raman scattering (SERS) spectroscopy substrates. Novel substrates that produce an exceptionally large enhancement of the Raman effect were used to amplify the Raman signal of explosives...

  13. Radiometric calipers for borehole logging

    International Nuclear Information System (INIS)

    Charbucinski, J.; Wylie, A.W.; Jarrett, R.G.

    1976-01-01

    Two versions of a radiometric-type caliper for measuring borehole diameter are described. One, based on the bow-spring principle, is suitable for percussion (exploration) drill holes. The other, which utilizes hemispherical wall contactors actuated by springs, is suitable for blast holes. Both utilize low-power radioactive sources and employ a scintillation detector to measure the 'inverse-square law' response of the device to changes in borehole radius. The performance of the device is examined and examples of its use are illustrated. (author)

  14. Detectability of hepatocellular carcinoma: comparison of Gd-DTPA-enhanced and SPIO-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Lee, Jeong Min; Kim In Hwan; Kim, Chong Soo; Han, Hyeun Young; Yoon, Kwon ha; Shin, Kyung Sook

    2000-01-01

    To compare the detectability of hepatocellular carcinoma (HCC) using superparamagnetic iron oxide (SPIO)-enhanced T2-weighted turbo spin echo (TSE), SPIO-enhanced T2-weighted FISP, and dynamic Gd-DTPA-enhanced fast low-angle shot (FLASH) MR images. In order to assess their hepatic lesions, 25 patients (20 men and 5 women) with HCC were enrolled in an MR study in which both gadolinium and Spiro were used. Since the lesions were most conspicuous during the phase of dynamic arterial dominant phase of dynamic gadolinium-enhanced imaging, this was the phase used for analysis. Images were analyzed qualitatively and quantitatively, and to compare the diagnostic value of gadolinium-enhanced imaging with that of SPIO-enhanced imaging for the detection of HCCs, a receiver-operated characteristic curve was obtained. Qualitative analysis revealed a significantly higher percentage of signal loss and a higher liver-lesion contrast-to-noise ratio on SPIO-enhanced FISP imaging than on SPIO-enhanced T2-weighted TSE imaging (p less than 0.05). It also showed that the lesions were most clearly visible on SPIO-enhanced FISP imaging (and significantly so), followed by SPIO-enhanced T2-weighted TSE imaging, and dynamic gadolinium-enhanced imaging. Imaging artifacts were more prominent on SPIO-enhanced T2-weighted TSE than on SPIO-enhanced PISF imaging or dynamic gadolinium-enhanced imaging (p less than 0.05). According to ROC analysis, SPIO-enhanced T2-weighted turbo spin echo (TSE) or SPIO-enhanced FISP imaging achieved higher accuracy than did dynamic gadolinium-enhanced FLASH imaging (p less than 0.05). For the detection of hepatocellular carcinomas, SPIO-enhanced MR imaging is better than gadolinium-enhanced FLASH imaging

  15. Enhancement of kalman filter single loss detection capability

    International Nuclear Information System (INIS)

    Morrison, G.W.; Downing, D.J.; Pike, D.H.

    1980-01-01

    A new technique to significantly increase the sensitivity of the Kalman filter to detect one-time losses for nuclear marterial accountability and control has been developed. The technique uses the innovations sequence obtained from a Kalman filter analysis of a material balance area. The innovations are distributed as zero mean independent Gaussion random variables with known variance. This property enables an estimator to be formed with enhanced one time loss detection capabilities. Simulation studies of a material balance area indicate the new estimator greatly enhances the one time loss detection capability of the Kalman filter

  16. Enhanced urinalysis in the detection of asymptomatic bacteriuria in pregnancy.

    Science.gov (United States)

    Aigere, E O S; Okusanya, B O; Eigbefoh, J O; Okome, G B O

    2013-01-01

    Detection and treatment of asymptomatic bacteriuria (ASB) in pregnancy is important to avert the attendant maternal and fetal morbidity. Other than urine culture, no other screening test is unequivocal. The use of enhanced urinalysis test to detect ASB in pregnancy was investigated. This was a prospective observational study which compared enhanced urinalysis with dipstick tests and urine culture. Clean catch midstream urine specimen was collected from 150 consecutive asymptomatic pregnant women. Tests of validity were used for comparison. Enhanced urinalysis detected bacteriuria as much as urine culture (4% vs. 4.7%). Itwas 57.1% sensitive and 98.6% specific. It had a false negative rate of 42.9% and was 96.7% accurate when compared to urine culture. Enhanced urinalysis took 1-2 hours to be done and required skills to use the microscope and was more expensive than dipstick urinalysis. The accuracy of enhanced urinalysis and its ability to detect ASB as much as urine culture connotes that it can be used to detect asymptomatic bacteriuria in pregnancy albeit only in secondary and tertiary health centres because of the cost and technicality involved.

  17. Optimal Noise Enhanced Signal Detection in a Unified Framework

    Directory of Open Access Journals (Sweden)

    Ting Yang

    2016-06-01

    Full Text Available In this paper, a new framework for variable detectors is formulated in order to solve different noise enhanced signal detection optimal problems, where six different disjoint sets of detector and discrete vector pairs are defined according to the two inequality-constraints on detection and false-alarm probabilities. Then theorems and algorithms constructed based on the new framework are presented to search the optimal noise enhanced solutions to maximize the relative improvements of the detection and the false-alarm probabilities, respectively. Further, the optimal noise enhanced solution of the maximum overall improvement is obtained based on the new framework and the relationship among the three maximums is presented. In addition, the sufficient conditions for improvability or non-improvability under the two certain constraints are given. Finally, numerous examples are presented to illustrate the theoretical results and the proofs of the main theorems are given in the Appendix.

  18. Radiometric geochronology of the Himalaya

    International Nuclear Information System (INIS)

    Saini, H.S.

    1982-01-01

    The radiometric age data obtained by different dating methods have been interpreted in terms of possible orogenic activities prevailing in the Himalaya. In general, the age data confirm four main events, the Precambrian, the Late Precambrian-Cambrian Assyntian (Caledonian), the Late Palaeozoic-Hercynian and the Late Cretaceous-Tertiary Himalayan orogeny. The mineral dates are particularly significant in delineating different phases of the last i.e. the Himalayan orogeny which indicates main activity of the young Himalayan metamorphism around 70 to 50 Ma and followed by a momentous phase of major uplift during 25 to 10 Ma, which was responsible for the rise of the deeper part of the Himalaya into great folds and thrust slices and the formation of nappe structures. (author)

  19. Radiometric and dosimetric characteristics of HgI2 detectors

    International Nuclear Information System (INIS)

    Zaletin, V.M.; Krivozubov, O.V.; Torlin, M.A.; Fomin, V.I.

    1988-01-01

    The characteristics of HgI 2 detectors in x-ray and gamma detection in applications to radiometric and dosimetric monitoring and as portable instruments for such purposes was considered. Blocks with mosaic and sandwich structures were prepared and tested against each other and, for comparative purposes, against CdTe detectors for relative sensitivities at various gamma-quanta energies. Sensitivity dependencies on gamma radiation energy were plotted for the detector materials and structures as were current dependencies on the dose rate of x rays. Results indicated that the mercury iodide detectors could be used in radiometric and dosimetric measurements at gamma quantum energies up to and in excess of 1000 KeV

  20. Enhanced Detection of Human Plasma Proteins on Nanostructured Silver Surfaces

    Directory of Open Access Journals (Sweden)

    Zuzana Orságová Králová

    2013-08-01

    enhancement factor of 3.6×102 was achieved for a band with a Raman shift of 2104cm‐1 for globulin deposited onto silver nanostructured film on unpolished stainless steel substrate. The detection limit was 400g/mL. Plasma or serum could present a preferable material for non‐ invasive cancer disease diagnosis using the SERS method.

  1. Novel polymeric biochips for enhanced detection of infectious diseases

    CERN Document Server

    Hosseini, Samira

    2016-01-01

    This book focuses on the creation and development of polymeric platforms (different compositions) from a specific polymer system. This system can be used as an adaptive technique for producing sensitive analytical devices, or for simple integration into existing bioanalytical tools in order to enhance the detection signal.

  2. Entanglement enhanced thermometry in the detection of the Unruh effect

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Zehua, E-mail: zehuatian@126.com [Institute of Theoretical Physics, University of Warsaw, Pasteura 5, 02-093 Warsaw (Poland); Wang, Jieci [Department of Physics, Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, Hunan Normal University, Changsha, Hunan 410081 (China); Synergetic Innovation Center for Quantum Effects and Applications, Hunan Normal University, Changsha, Hunan 410081 (China); Jing, Jiliang, E-mail: jljing@hunn.edu.cn [Department of Physics, Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, Hunan Normal University, Changsha, Hunan 410081 (China); Synergetic Innovation Center for Quantum Effects and Applications, Hunan Normal University, Changsha, Hunan 410081 (China); Dragan, Andrzej, E-mail: dragan@fuw.edu.pl [Institute of Theoretical Physics, University of Warsaw, Pasteura 5, 02-093 Warsaw (Poland)

    2017-02-15

    We show how the use of entanglement can enhance the precision of the detection of the Unruh effect with an accelerated probe. We use a two-level atom interacting relativistically with a quantum field as the probe, and treat it as an open quantum system to derive the master equation governing its evolution. By means of quantum state discrimination, we detect the accelerated motion of the atom by examining its time evolving state. It turns out that the optimal strategy for the detection of the Unruh effect, to which the accelerated atom is sensitive, involves letting the atom-thermometer equilibrate with the thermal bath. However, introducing initial entanglement between the detector and an external degree of freedom leads to an enhancement of the sensitivity of the detector. Also, the maximum precision is attained within finite time, before equilibration takes place.

  3. Lack of clinical relevance in routine final subcultures of radiometrically negative BACTEC blood culture vials

    International Nuclear Information System (INIS)

    Plorde, J.J.; Carlson, L.G.; Dau, M.E.

    1982-01-01

    During a 38-month period, 10,106 blood specimens were received in the laboratory for culture. These were inoculated into 26,424 vials and processed using the BACTEC radiometric detection system. Of these vials, 1,914 were eventually found to be microbiologically positive. Isolates from 836 vials were judged to be contaminants. In the remaining 1,078 vials, growth was first detected visually or radiometrically in 1,062 and by final subculture in 16. Growth from these sixteen bottles represented 12 clinically significant bacteremic episodes in as many patients. In nine of these episodes, other culture vials from the same patient were positive radiometrically. Therefore, 358 of 361 (99.2%) bacteremic episodes were detected without the benefit of routine final subcultures. The three patients whose bacteremia was missed were diagnosed clinically and placed on appropriate therapy prior to the detection of the bacteremias by final subculture

  4. The Radiometric Bode's law and Extrasolar Planets

    National Research Council Canada - National Science Library

    Lazio, T. J; Farrell, W. M; Dietrick, Jill; Greenlees, Elizabeth; Hogan, Emily; Jones, Christopher; Hennig, L. A

    2004-01-01

    We predict the radio flux densities of the extrasolar planets in the current census, making use of an empirical relation the radiometric Bode's law determined from the five "magnetic" planets in the solar system...

  5. Ash content of lignites - radiometric analysis

    International Nuclear Information System (INIS)

    Leonhardt, J.; Thuemmel, H.W.

    1986-01-01

    The quality of lignites is governed by the ash content varying in dependence upon the geologic conditions. Setup and function of the radiometric devices being used for ash content analysis in the GDR are briefly described

  6. Modified and reverse radiometric flow injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Ba, H; Khin, M M; Aung, K; Thida, [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-06-01

    Determination of [sup 137]Cs and [sup 60]Co by using modified and reverse radiometric flow injection analysis is described. Two component RFIA was also realized using [sup 60]Co and [sup 137]Cs radionuclides. (author) 2 refs.; 5 figs.

  7. RADIOMETRIC CALIBRATION OF AIRBORNE LASER SCANNING DATA

    OpenAIRE

    Pilarska Magdalena

    2016-01-01

    Airborne laser scanning (ALS) is widely used passive remote sensing technique. The radiometric calibration of ALS data is presented in this article. This process is a necessary element in data processing since it eliminates the influence of the external factors on the obtained values of radiometric features such as range and incidence angle. The datasets were captured with three different laser scanners; since each of these operates at a different wavelength (532, 106 4 and 1550 nm) th...

  8. Training course on radiometric prospecting techniques

    International Nuclear Information System (INIS)

    1979-01-01

    A training course on radiometric prospecting techniques was presented by the Atomic Energy Board in collaboration with the South African Geophysical Association and the Geological Society of South Africa. Various aspects related to uranium prospecting were discussed e.g. the uranium supply and demand position, the basic physics of radioactivity, uranium geochemistry, mineralogy and mobility, the instrumentation and techniques used in uranium exploration, for example, borehole logging, radon emanometry and airborne radiometric surveys and also data processing and interpretation methods

  9. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  10. Ultra-sensitive radionuclide spectrometry. Radiometrics and mass spectrometry synergy

    International Nuclear Information System (INIS)

    Povinec, P.P.

    2005-01-01

    Recent developments in radiometrics and mass spectrometry techniques for ultra-sensitive analysis of radionuclides in the marine environment are reviewed. In the radiometrics sector the dominant development has been the utilization of large HPGe detectors in underground laboratories with anti-cosmic or anti-Compton shielding for the analysis of short and medium-lived radionuclides in the environment. In the mass spectrometry sector, applications of inductively coupled plasma mass spectrometry (ICP-MS) and accelerator mass spectrometry (AMS) for the analysis of long-lived radionuclides in the environment are the most important recent achievements. The recent developments do not only considerably decrease the detection limits for several radionuclides (up to several orders of magnitude), but they also enable to decrease sample volumes so that sampling, e.g., of the water column can be much easier and more effective. A comparison of radiometrics and mass spectrometry results for the analysis of radionuclides in the marine environment shows a reasonable agreement - within quoted uncertainties, for wide range of activities and different sample matrices analyzed. (author)

  11. Unexpected Coexisting Myocardial Infarction Detected by Delayed Enhancement MRI

    Directory of Open Access Journals (Sweden)

    Edouard Gerbaud

    2009-01-01

    Full Text Available We report a case of an unexpected coexisting anterior myocardial infarction detected by delayed enhancement MRI in a 41-year-old man following a presentation with a first episode of chest pain during inferior acute myocardial infarction. This second necrotic area was not initially suspected because there were no ECG changes in the anterior leads and the left descending coronary artery did not present any significant stenoses on emergency coronary angiography. Unrecognised myocardial infarction may carry important prognostic implications. CMR is currently the best imaging technique to detect unexpected infarcts.

  12. Ultrasensitive detection of phenolic antioxidants by surface enhanced Raman spectroscopy

    Science.gov (United States)

    Ornelas-Soto, N.; Aguilar-Hernández, I. A.; Afseth, N.; López-Luke, T.; Contreras-Torres, F. F.; Wold, J. P.

    2017-08-01

    Surface-Enhanced Raman Spectroscopy (SERS) is a powerful surface-sensitive technique to study the vibrational properties of analytes at very low concentrations. In this study, ferulic acid, p-coumaric acid, caffeic acid and sinapic acid were analyzed by SERS using Ag colloids. Analytes were detected up to 2.5x10-9M. For caffeic acid and coumaric acid, this detection limit has been reached for the first time, as well as the SERS analysis of sinapic acid using silver colloids.

  13. Detection with Enhanced Energy Windowing Phase I Report

    Energy Technology Data Exchange (ETDEWEB)

    Bass, David A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Enders, Alexander L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-12-01

    This document reviews the progress of Phase I of the Detection with Enhanced Energy Windowing (DEEW) project. The DEEW project is the implementation of software incorporating an algorithm which reviews data generated by radiation portal monitors and utilizes advanced and novel techniques for detecting radiological and fissile material while not alarming on Naturally Occurring Radioactive Material. Independent testing indicated that the Enhanced Energy Windowing algorithm showed promise at reducing the probability of alarm in the stream of commerce compared to existing algorithms and other developmental algorithms, while still maintaining adequate sensitivity to threats. This document contains a brief description of the project, instructions for setting up and running the applications, and guidance to help make reviewing the output files and source code easier.

  14. Sentinel node detection in melanomas using contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Nielsen, K. Rue; Klyver, H.; Chakera, A. Hougaard

    2009-01-01

    in humans. PURPOSE: To investigate the possible use of CEUS in detecting SN in patients with malignant melanomas (MM), and to improve the method by using different concentrations of contrast agent and various positions of the extremity. MATERIAL AND METHODS: Ten patients with MM on an extremity and one...... healthy volunteer were included. One milliliter of a contrast agent (Sonovue; Bracco, Milan, Italy) was injected subcutaneously on both sides of the scar from the excised tumor. Contrast-enhanced lymph channels and lymph nodes (LNs) were searched for using low-mechanical-index CEUS and by stimulated...... tissue damage, as the contrast agent was not registered for subcutaneous administration. RESULTS: In one patient, two contrast-enhanced inguinal LNs were visualized by CEUS, corresponding to two inguinal SNs found by scintigraphic imaging. No contrast-enhanced lymph channels or LNs were visualized in any...

  15. Limulus test for pyrogens and radiometric sterility tests on radiopharmaceuticals. Part of a coordinated programme

    International Nuclear Information System (INIS)

    Gopal, N.G.S.

    1976-10-01

    Sterility testing of radiopharmaceuticals prepared at BARC were carried out using the radiometric technique (Radiometric detection of the metabolic product 14 Co 2 ). Batches of different radiopharmaceuticals were tested for pyrogen using the limulus lysate method and the results were compared with the rabbit method. The results of sterility test on 202 batches of 19 different radiopharmaceuticals show that the radiometric method can be used for sterility testing of radiopharmaceuticals labelled with 35 S, 51 Cr, 57 Co, 59 Fe, 82 Br, 86 Rb, sup(99m)Tc, sup(113m)In, 125 I and 169 Yb. The radiometric test proves to be more rapid than the conventional one for the sterility testing of such radiopharmaceuticals. Detection time is between 6-21 hours. In the case of 131 I-labelled radiopharmaceuticals and in the case of chlormerodrin-Hg-203, it was found an interference due to volatile species (sup(131m)Xe in the case of 131 I and some volatile mercury form in the case of chlormerodrin). In these cases it would be possible to carry out the radiometric sterility test after separation of the microorganisms from the radioactive material (by filtration). The limulus lysate method can be employed for control of various pyrogen-prone raw materials and radiopharmaceuticals. Such method is the only method at present available for detecting the low level pyrogen contamination in intrathecal injections. The limulus test is more rapid than the rabbit test

  16. Ultraviolet Resonant Raman Enhancements in the Detection of Explosives

    Energy Technology Data Exchange (ETDEWEB)

    Short Jr., Billy Joe [Naval Postgraduate School, Monterey, CA (United States)

    2009-06-01

    Raman-based spectroscopy is potentially militarily useful for standoff detection of high explosives. Normal (non-resonance) and resonance Raman spectroscopies are both light scattering techniques that use a laser to measure the vibrational spectrum of a sample. In resonance Raman, the laser is tuned to match the wavelength of a strong electronic absorbance in the molecule of interest, whereas, in normal Raman the laser is not tuned to any strong electronic absorbance bands. The selection of appropriate excitation wavelengths in resonance Raman can result in a dramatic increase in the Raman scattering efficiency of select band(s) associated with the electronic transition. Other than the excitation wavelength, however, resonance Raman is performed experimentally the same as normal Raman. In these studies, normal and resonance Raman spectral signatures of select solid high explosive (HE) samples and explosive precursors were collected at 785 nm, 244 nm and 229 nm. Solutions of PETN, TNT, and explosive precursors (DNT & PNT) in acetonitrile solvent as an internal Raman standard were quantitatively evaluated using ultraviolet resonance Raman (UVRR) microscopy and normal Raman spectroscopy as a function of power and select excitation wavelengths. Use of an internal standard allowed resonance enhancements to be estimated at 229 nm and 244 nm. Investigations demonstrated that UVRR provided ~2000-fold enhancement at 244 nm and ~800-fold improvement at 229 nm while PETN showed a maximum of ~25-fold at 244 nm and ~190-fold enhancement at 229 nm solely from resonance effects when compared to normal Raman measurements. In addition to the observed resonance enhancements, additional Raman signal enhancements are obtained with ultraviolet excitation (i.e., Raman scattering scales as !4 for measurements based on scattered photons). A model, based partly on the resonance Raman enhancement results for HE solutions, is presented for estimating Raman enhancements for solid HE samples.

  17. Discrepancy detection in the retrieval-enhanced suggestibility paradigm.

    Science.gov (United States)

    Butler, Brendon Jerome; Loftus, Elizabeth F

    2018-04-01

    Retrieval-enhanced suggestibility (RES) refers to the finding that immediately recalling the details of a witnessed event can increase susceptibility to later misinformation. In three experiments, we sought to gain a deeper understanding of the role that retrieval plays in the RES paradigm. Consistent with past research, initial testing did increase susceptibility to misinformation - but only for those who failed to detect discrepancies between the original event and the post-event misinformation. In all three experiments, subjects who retrospectively detected discrepancies in the post-event narratives were more resistant to misinformation than those who did not. In Experiments 2 and 3, having subjects concurrently assess the consistency of the misinformation narratives negated the RES effect. Interestingly, in Experiments 2 and 3, subjects who had retrieval practice and detected discrepancies were more likely to endorse misinformation than control subjects who detected discrepancies. These results call attention to limiting conditions of the RES effect and highlight the complex relationship between retrieval practice, discrepancy detection, and misinformation endorsement.

  18. Radiometric system for clinical applications in the National Health System

    International Nuclear Information System (INIS)

    Mesa Perez, G.; Arteche Diaz, R.; Camejo Batista, A.; Fonfria Bragado, C.

    2013-01-01

    In this paper it is presented the radiometric detection system SRNIC-02, manufactured at CEADEN. The system has three major components: a well-type Nal(TI) scintillator detector with its collimator, a measurement module, and the application software, which allows fixing the working parameters of the system, as well as the acquisition and processing of data. The system has two main applications in the National Health System, one for the quality control in Radiopharmacy, and in RIA/IRMA blood tests. There are 16 systems installed, in 13 provinces of the country up to this date. (Author)

  19. Panay carborne radiometric and geochemical surveys

    International Nuclear Information System (INIS)

    Santos, G. Jr.

    1981-09-01

    A carborne radiometric survey and stream sediments collection were conducted in Panay and Guimaras Islands. An area in Nabas, Aklan, situated in the northwestern tip of Panay (Buruanga Peninsula) which indicated 2 to 3 times above background radioactivity was delineated. Uranium content in the stream sediment samples collected from Buruanga Peninsula was generally higher than those obtained in other parts of the island. Radioactivity measurements and uranium content in stream sediments were found to be within background levels. It is recommended that follow-up radiometric and geochemical surveys be undertaken in Buruanga Peninsula and additional stream sediments samples be collected in Panay to achieve better sampling density and coverage. (author)

  20. Radiometric study of creep in ingot rolling

    International Nuclear Information System (INIS)

    Kubicek, P.; Zamyslovsky, Z.; Uherek, J.

    The radiometric study of creep during ingot rolling performed in the rolling mill of the Vitkovice Iron and Steel Works and the first results are described. Selected sites in 3 to 8 ton ingots were labelled with 2 to 3.7x10 5 Bq of 60 Co and after rolling into blocks, the transposition of the labelled sites of the ingots was investigated. The results indicate creep during rolling, local extension in certain sites under study and help to determine the inevitable bottom crop incurred in the forming. Finally, the requirements put on the radiometric apparatus for the next stages of technological research are presented. (author)

  1. Image enhancement using thermal-visible fusion for human detection

    Science.gov (United States)

    Zaihidee, Ezrinda Mohd; Hawari Ghazali, Kamarul; Zuki Saleh, Mohd

    2017-09-01

    An increased interest in detecting human beings in video surveillance system has emerged in recent years. Multisensory image fusion deserves more research attention due to the capability to improve the visual interpretability of an image. This study proposed fusion techniques for human detection based on multiscale transform using grayscale visual light and infrared images. The samples for this study were taken from online dataset. Both images captured by the two sensors were decomposed into high and low frequency coefficients using Stationary Wavelet Transform (SWT). Hence, the appropriate fusion rule was used to merge the coefficients and finally, the final fused image was obtained by using inverse SWT. From the qualitative and quantitative results, the proposed method is more superior than the two other methods in terms of enhancement of the target region and preservation of details information of the image.

  2. RNA interference for performance enhancement and detection in doping control.

    Science.gov (United States)

    Kohler, Maxie; Schänzer, Wilhelm; Thevis, Mario

    2011-10-01

    RNA interference represents a comparably new route of regulating and manipulating specific gene expression. Promising results were obtained in experimental therapies aim at the treatment of different kinds of diseases including cancer, diabetes mellitus or Dychenne muscular dystrophy. While studies on down-regulation efficiency are often performed by analyzing the regulated protein, the direct detection of small, interfering RNA molecules and antisense oligonucleotides is of great interest for the investigation of the metabolism and degradation and also for the detection of a putative misuse of these molecules in sports. Myostatin down-regulation was shown to result in increased performance and muscle growth and the regulation of several other proteins could be relevant for performance enhancement. This mini-review summarizes current approaches for the mass spectrometric analysis of siRNA and antisense oligonucleotides from biological matrices and the available data on biodistribution, metabolism, and half-life of relevant substances are discussed. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Local correlation detection with linearity enhancement in streaming data

    KAUST Repository

    Xie, Qing

    2013-01-01

    This paper addresses the challenges in detecting the potential correlation between numerical data streams, which facilitates the research of data stream mining and pattern discovery. We focus on local correlation with delay, which may occur in burst at different time in different streams, and last for a limited period. The uncertainty on the correlation occurrence and the time delay make it diff cult to monitor the correlation online. Furthermore, the conventional correlation measure lacks the ability of ref ecting visual linearity, which is more desirable in reality. This paper proposes effective methods to continuously detect the correlation between data streams. Our approach is based on the Discrete Fourier Transform to make rapid cross-correlation calculation with time delay allowed. In addition, we introduce a shape-based similarity measure into the framework, which ref nes the results by representative trend patterns to enhance the signif cance of linearity. The similarity of proposed linear representations can quickly estimate the correlation, and the window sliding strategy in segment level improves the eff ciency for online detection. The empirical study demonstrates the accuracy of our detection approach, as well as more than 30% improvement of eff ciency. Copyright 2013 ACM.

  4. RADIOMETRIC TECHNIQUES IN HEAVY MINERAL EXPLORATION AND EXPLOITATION

    NARCIS (Netherlands)

    DEMEIJER, RJ; TANCZOS, IC; STAPEL, C

    1994-01-01

    In recent years the Environmental Research Group of the KVI has been developing a number of radiometric techniques that may be employed in mineral sand exploration. These techniques involve: radiometric fingerprinting for assessing sand provenances and mineralogical composition; thermoluminescence

  5. Radiometric measuring method for egg shells

    Energy Technology Data Exchange (ETDEWEB)

    Forberg, S; Svaerdstroem, K

    1973-02-01

    A description is given of a fast nondestructive radiometric method for registration of the thickness of egg shells of the tawny owl, hen, osprey, and Canada goose. Certain errors are discussed. Measurement of the thickness of egg shells (mineral content per cm/sup 2/) with an accuracy better than 1% is possible in less than one minute under field conditions. (auth)

  6. Mixing geometric and radiometric features for change classification

    Science.gov (United States)

    Fournier, Alexandre; Descombes, Xavier; Zerubia, Josiane

    2008-02-01

    Most basic change detection algorithms use a pixel-based approach. Whereas such approach is quite well defined for monitoring important area changes (such as urban growth monitoring) in low resolution images, an object based approach seems more relevant when the change detection is specifically aimed toward targets (such as small buildings and vehicles). In this paper, we present an approach that mixes radiometric and geometric features to qualify the changed zones. The goal is to establish bounds (appearance, disappearance, substitution ...) between the detected changes and the underlying objects. We proceed by first clustering the change map (containing each pixel bitemporal radiosity) in different classes using the entropy-kmeans algorithm. Assuming that most man-made objects have a polygonal shape, a polygonal approximation algorithm is then used in order to characterize the resulting zone shapes. Hence allowing us to refine the primary rough classification, by integrating the polygon orientations in the state space. Tests are currently conducted on Quickbird data.

  7. Liquid scintillation vial for radiometric assay of lymphocyte carbohydrate metabolism in response to mitogens

    International Nuclear Information System (INIS)

    Tran, N.; Wagner, H.N. Jr.

    1978-01-01

    We have demonstrated that mitogens--i.e., PHA and Con.A--stimulate lymphocyte carbohydrate metabolism using a liquid-scintillation vial with conventional liquid-scintillation detectors. The results showed that this enclosed system can be useful for development of rapid in vitro tests of lymphocytes immune responsiveness, as well as for radiometric detection of bacterial growth in various gaseous atmospheres

  8. Automatic Radiometric Normalization of Multitemporal Satellite Imagery with the Iteratively Re-weighted MAD Transformation

    DEFF Research Database (Denmark)

    Canty, Morton John; Nielsen, Allan Aasbjerg

    2008-01-01

    A recently proposed method for automatic radiometric normalization of multi- and hyper-spectral imagery based on the invariance property of the Multivariate Alteration Detection (MAD) transformation and orthogonal linear regression is extended by using an iterative re-weighting scheme involving no...

  9. Carbon Nanotube-based microelectrodes for enhanced detection of neurotransmitters

    Science.gov (United States)

    Jacobs, Christopher B.

    Fast-scan cyclic voltammetry (FSCV) is one of the common techniques used for rapid measurement of neurotransmitters in vivo. Carbon-fiber microelectrodes (CFMEs) are typically used for neurotransmitter detection because of sub-second measurement capabilities, ability to measure changes in neurotransmitter concentration during neurotransmission, and the small size electrode diameter, which limits the amount of damage caused to tissue. Cylinder CFMEs, typically 50 -- 100 microm long, are commonly used for in vivo experiments because the electrode sensitivity is directly related to the electrode surface area. However the length of the electrode can limit the spatial resolution of neurotransmitter detection, which can restrict experiments in Drosophila and other small model systems. In addition, the electrode sensitivity toward dopamine and serotonin detection drops significantly for measurements at rates faster than 10 Hz, limiting the temporal resolution of CFMEs. While the use of FSCV at carbon-fiber microelectrodes has led to substantial strides in our understanding of neurotransmission, techniques that expand the capabilities of CFMEs are crucial to fully maximize the potential uses of FSCV. This dissertation introduces new methods to integrate carbon nanotubes (CNT) into microelectrodes and discusses the electrochemical enhancements of these CNT-microelectrodes. The electrodes are specifically designed with simple fabrication procedures so that highly specialized equipment is not necessary, and they utilize commercially available materials so that the electrodes could be easily integrated into existing systems. The electrochemical properties of CNT modified CFMEs are characterized using FSCV and the effect of CNT functionalization on these properties is explored in Chapter 2. For example, CFME modification using carboxylic acid functionalized CNTs yield about a 6-fold increase in dopamine oxidation current, but modification with octadecylamine CNTs results in a

  10. SWI enhances vein detection using gadolinium in multiple sclerosis

    International Nuclear Information System (INIS)

    Maggi, Pietro; Mazzoni, Lorenzo N; Moretti, Marco; Grammatico, Matteo; Chiti, Stefano; Massacesi, Luca

    2015-01-01

    Susceptibility weighted imaging (SWI) combined with the FLAIR sequence provides the ability to depict in vivo the perivenous location of inflammatory demyelinating lesions – one of the most specific pathologic features of multiple sclerosis (MS). In addition, in MS white matter (WM) lesions, gadolinium-based contrast media (CM) can increase vein signal loss on SWI. This report focuses on two cases of WM inflammatory lesions enhancing on SWI images after CM injection. In these lesions in fact the CM increased the contrast between the parenchyma and the central vein allowing as well, in one of the two cases, the detection of a vein not visible on the same SWI sequence acquired before CM injection

  11. Enhancement and denoising of mammographic images for breast disease detection

    International Nuclear Information System (INIS)

    Yazdani, S.; Yusof, R.; Karimian, A.; Hematian, A.; Yousefi, M.

    2012-01-01

    In these two decades breast cancer is one of the leading cause of death among women. In breast cancer research, Mammographic Image is being assessed as a potential tool for detecting breast disease and investigating response to chemotherapy. In first stage of breast disease discovery, the density measurement of the breast in mammographic images provides very useful information. Because of the importance of the role of mammographic images the need for accurate and robust automated image enhancement techniques is becoming clear. Mammographic images have some disadvantages such as, the high dependence of contrast upon the way the image is acquired, weak distinction in splitting cyst from tumor, intensity non uniformity, the existence of noise, etc. These limitations make problem to detect the typical signs such as masses and microcalcifications. For this reason, denoising and enhancing the quality of mammographic images is very important. The method which is used in this paper is in spatial domain which its input includes high, intermediate and even very low contrast mammographic images based on specialist physician's view, while its output is processed images that show the input images with higher quality, more contrast and more details. In this research, 38 mammographic images have been used. The result of purposed method shows details of abnormal zones and the areas with defects so that specialist could explore these zones more accurately and it could be deemed as an index for cancer diagnosis. In this study, mammographic images are initially converted into digital images and then to increase spatial resolution power, their noise is reduced and consequently their contrast is improved. The results demonstrate effectiveness and efficiency of the proposed methods. (authors)

  12. Stochastic Resonance algorithms to enhance damage detection in bearing faults

    Directory of Open Access Journals (Sweden)

    Castiglione Roberto

    2015-01-01

    Full Text Available Stochastic Resonance is a phenomenon, studied and mainly exploited in telecommunication, which permits the amplification and detection of weak signals by the assistance of noise. The first papers on this technique are dated early 80 s and were developed to explain the periodically recurrent ice ages. Other applications mainly concern neuroscience, biology, medicine and obviously signal analysis and processing. Recently, some researchers have applied the technique for detecting faults in mechanical systems and bearings. In this paper, we try to better understand the conditions of applicability and which is the best algorithm to be adopted for these purposes. In fact, to get the methodology profitable and efficient to enhance the signal spikes due to fault in rings and balls/rollers of bearings, some parameters have to be properly selected. This is a problem since in system identification this procedure should be as blind as possible. Two algorithms are analysed: the first exploits classical SR with three parameters mutually dependent, while the other uses Woods-Saxon potential, with three parameters yet but holding a different meaning. The comparison of the performances of the two algorithms and the optimal choice of their parameters are the scopes of this paper. Algorithms are tested on simulated and experimental data showing an evident capacity of increasing the signal to noise ratio.

  13. Genome-Enhanced Detection and Identification (GEDI of plant pathogens

    Directory of Open Access Journals (Sweden)

    Nicolas Feau

    2018-02-01

    Full Text Available Plant diseases caused by fungi and Oomycetes represent worldwide threats to crops and forest ecosystems. Effective prevention and appropriate management of emerging diseases rely on rapid detection and identification of the causal pathogens. The increase in genomic resources makes it possible to generate novel genome-enhanced DNA detection assays that can exploit whole genomes to discover candidate genes for pathogen detection. A pipeline was developed to identify genome regions that discriminate taxa or groups of taxa and can be converted into PCR assays. The modular pipeline is comprised of four components: (1 selection and genome sequencing of phylogenetically related taxa, (2 identification of clusters of orthologous genes, (3 elimination of false positives by filtering, and (4 assay design. This pipeline was applied to some of the most important plant pathogens across three broad taxonomic groups: Phytophthoras (Stramenopiles, Oomycota, Dothideomycetes (Fungi, Ascomycota and Pucciniales (Fungi, Basidiomycota. Comparison of 73 fungal and Oomycete genomes led the discovery of 5,939 gene clusters that were unique to the targeted taxa and an additional 535 that were common at higher taxonomic levels. Approximately 28% of the 299 tested were converted into qPCR assays that met our set of specificity criteria. This work demonstrates that a genome-wide approach can efficiently identify multiple taxon-specific genome regions that can be converted into highly specific PCR assays. The possibility to easily obtain multiple alternative regions to design highly specific qPCR assays should be of great help in tackling challenging cases for which higher taxon-resolution is needed.

  14. Gas detection by means of surface plasmon resonance enhanced ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Nooke, Alida

    2012-11-01

    This thesis investigated gas sensing by means of surface plasmon resonance enhanced ellipsometry. Surface plasmons were excited in a 40 - 50 nm gold layer by a He-Ne-laser using the Kretschmann configuration, which was arranged on a self-made copper measuring cell. A fixed angle of incidence and the ellipsometric parameter {Delta} as the measured value were used to monitor changes in the gas phase. Different types of gases were investigated: flammable (hydrocarbons and hydrogen), oxidising (oxygen and ozone), toxic (carbon monoxide) and inert (helium and nitrogen). The gas types can be distinguished by their refractive indices, whereas the sensor responds instantly relative to the reference gas with an increase or a decrease in {Delta}. Diluting the analyte gas with a reference gas (nitrogen or air) allowed the detection limits to be determined, these lay in the low % range. The sensor stability was also enhanced as well as the sensitivity by modifying the gold layers with a 3-10 nm additional layer. These additional layers consisted of the inorganic materials TiO{sub 2}, ZrO{sub 2}, MgF{sub 2} and Fe: SnO{sub 2} which were deposited by different coating processes. Surface investigations were made of every utilised layer: scanning electron microscope and atomic force microscope measurements for surface topology and spectroscopic ellipsometry mapping to determine the optical constants and the layer thicknesses. All applied materials protected the gold layer from contaminations and thus prolonged the life span of the sensor. Furthermore, the detection limits were reduced significantly, to the low ppm range. The material Fe: SnO{sub 2} demonstrates a special behaviour in reaction with the toxic gas carbon monoxide: Due to the iron doping, the response to carbon monoxide is extraordinary and concentrations below 1 ppm were detected. In order to approach a future application in industry, the sensor system was adapted to a stainless steel tube. With this measuring

  15. Modeling response variation for radiometric calorimeters

    International Nuclear Information System (INIS)

    Mayer, R.L. II.

    1986-01-01

    Radiometric calorimeters are widely used in the DOE complex for accountability measurements of plutonium and tritium. Proper characterization of response variation for these instruments is, therefore, vital for accurate assessment of measurement control as well as for propagation of error calculations. This is not difficult for instruments used to measure items within a narrow range of power values; however, when a single instrument is used to measure items over a wide range of power values, improper estimates of uncertainty can result since traditional error models for radiometric calorimeters assume that uncertainty is not a function of sample power. This paper describes methods which can be used to accurately estimate random response variation for calorimeters used to measure items over a wide range of sample powers. The model is applicable to the two most common modes of calorimeter operation: heater replacement and servo control. 5 refs., 4 figs., 1 tab

  16. Substoichiometric method in the simple radiometric analysis

    International Nuclear Information System (INIS)

    Ikeda, N.; Noguchi, K.

    1979-01-01

    The substoichiometric method is applied to simple radiometric analysis. Two methods - the standard reagent method and the standard sample method - are proposed. The validity of the principle of the methods is verified experimentally in the determination of silver by the precipitation method, or of zinc by the ion-exchange or solvent-extraction method. The proposed methods are simple and rapid compared with the conventional superstoichiometric method. (author)

  17. Radiometric characterization of Landsat Collection 1 products

    Science.gov (United States)

    Micijevic, Esad; Haque, Md. Obaidul; Mishra, Nischal

    2017-09-01

    Landsat data in the U.S. Geological Survey (USGS) archive are being reprocessed to generate a tiered collection of consistently geolocated and radiometrically calibrated products that are suitable for time series analyses. With the implementation of the collection management, no major updates will be made to calibration of the Landsat sensors within a collection. Only calibration parameters needed to maintain the established calibration trends without an effect on derived environmental records will be regularly updated, while all other changes will be deferred to a new collection. This first collection, Collection 1, incorporates various radiometric calibration updates to all Landsat sensors including absolute and relative gains for Landsat 8 Operational Land Imager (OLI), stray light correction for Landsat 8 Thermal Infrared Sensor (TIRS), absolute gains for Landsat 4 and 5 Thematic Mappers (TM), recalibration of Landsat 1-5 Multispectral Scanners (MSS) to ensure radiometric consistency among different formats of archived MSS data, and a transfer of Landsat 8 OLI reflectance based calibration to all previous Landsat sensors. While all OLI/TIRS, ETM+ and majority of TM data have already been reprocessed to Collection 1, a completion of MSS and remaining TM data reprocessing is expected by the end of this year. It is important to note that, although still available for download from the USGS web pages, the products generated using the Pre-Collection processing do not benefit from the latest radiometric calibration updates. In this paper, we are assessing radiometry of solar reflective bands in Landsat Collection 1 products through analysis of trends in on-board calibrator and pseudo invariant site (PICS) responses.

  18. Radiometric relations of a sugarcane crop

    International Nuclear Information System (INIS)

    Machado, E.C.; Pereira, A.R.; Camargo, M.B.P. de; Fahl, J.I.

    1985-01-01

    The radiometric relations of a sugarcane crop, cv. NA56-79, are studied during the period of maximum leaf area index. The coefficients of reflection, transmission and absorption of the incoming solar radiation were function of solar elevation and the waveband considered. The photosynthetically active radiation was always less reflected and transmitted but more absorved than the near infrared radiation. (M.A.C.) [pt

  19. GEOMETRIC AND RADIOMETRIC EVALUATION OF RASAT IMAGES

    Directory of Open Access Journals (Sweden)

    A. Cam

    2016-06-01

    Full Text Available RASAT, the second remote sensing satellite of Turkey, was designed and assembled, and also is being operated by TÜBİTAK Uzay (Space Technologies Research Institute (Ankara. RASAT images in various levels are available free-of-charge via Gezgin portal for Turkish citizens. In this paper, the images in panchromatic (7.5 m GSD and RGB (15 m GSD bands in various levels were investigated with respect to its geometric and radiometric characteristics. The first geometric analysis is the estimation of the effective GSD as less than 1 pixel for radiometrically processed level (L1R of both panchromatic and RGB images. Secondly, 2D georeferencing accuracy is estimated by various non-physical transformation models (similarity, 2D affine, polynomial, affine projection, projective, DLT and GCP based RFM reaching sub-pixel accuracy using minimum 39 and maximum 52 GCPs. The radiometric characteristics are also investigated for 8 bits, estimating SNR between 21.8-42.2, and noise 0.0-3.5 for panchromatic and MS images for L1R when the sea is masked to obtain the results for land areas. The analysis show that RASAT images satisfies requirements for various applications. The research is carried out in Zonguldak test site which is mountainous and partly covered by dense forest and urban areas.

  20. Enhanced

    Directory of Open Access Journals (Sweden)

    Martin I. Bayala

    2014-06-01

    Full Text Available Land Surface Temperature (LST is a key parameter in the energy balance model. However, the spatial resolution of the retrieved LST from sensors with high temporal resolution is not accurate enough to be used in local-scale studies. To explore the LST–Normalised Difference Vegetation Index relationship potential and obtain thermal images with high spatial resolution, six enhanced image sharpening techniques were assessed: the disaggregation procedure for radiometric surface temperatures (TsHARP, the Dry Edge Quadratic Function, the Difference of Edges (Ts∗DL and three models supported by the relationship of surface temperature and water stress of vegetation (Normalised Difference Water Index, Normalised Difference Infrared Index and Soil wetness index. Energy Balance Station data and in situ measurements were used to validate the enhanced LST images over a mixed agricultural landscape in the sub-humid Pampean Region of Argentina (PRA, during 2006–2010. Landsat Thematic Mapper (TM and Moderate Resolution Imaging Spectroradiometer (EOS-MODIS thermal datasets were assessed for different spatial resolutions (e.g., 960, 720 and 240 m and the performances were compared with global and local TsHARP procedures. Results suggest that the Ts∗DL technique is the most adequate for simulating LST to high spatial resolution over the heterogeneous landscape of a sub-humid region, showing an average root mean square error of less than 1 K.

  1. Rapid surface enhanced Raman scattering detection method for chloramphenicol residues

    Science.gov (United States)

    Ji, Wei; Yao, Weirong

    2015-06-01

    Chloramphenicol (CAP) is a widely used amide alcohol antibiotics, which has been banned from using in food producing animals in many countries. In this study, surface enhanced Raman scattering (SERS) coupled with gold colloidal nanoparticles was used for the rapid analysis of CAP. Density functional theory (DFT) calculations were conducted with Gaussian 03 at the B3LYP level using the 3-21G(d) and 6-31G(d) basis sets to analyze the assignment of vibrations. Affirmatively, the theoretical Raman spectrum of CAP was in complete agreement with the experimental spectrum. They both exhibited three strong peaks characteristic of CAP at 1104 cm-1, 1344 cm-1, 1596 cm-1, which were used for rapid qualitative analysis of CAP residues in food samples. The use of SERS as a method for the measurements of CAP was explored by comparing use of different solvents, gold colloidal nanoparticles concentration and absorption time. The method of the detection limit was determined as 0.1 μg/mL using optimum conditions. The Raman peak at 1344 cm-1 was used as the index for quantitative analysis of CAP in food samples, with a linear correlation of R2 = 0.9802. Quantitative analysis of CAP residues in foods revealed that the SERS technique with gold colloidal nanoparticles was sensitive and of a good stability and linear correlation, and suited for rapid analysis of CAP residue in a variety of food samples.

  2. Radiometric microassay for ornithine decarboxylase

    Energy Technology Data Exchange (ETDEWEB)

    Maderdrut, J L; Oppenheim, R W [North Carolina Univ., Chapel Hill (USA). School of Medicine

    1978-01-01

    A simple method for purifying (/sup 3/H)L-ornithine and incubation conditions suitable for estimating L-ornithine decarboxylase activity are described. Routine and recycle cation exchange procedures for separating putrescine from ornithine are outlined. Blanks using the routine cation exchange method average approx. 0.04% of the radioactivity contained in the substrate; product recovery is approx. 94%. The L-ornithine decarboxylase assay is proportional to time for at least 8 h. The relationship between substrate purity and the sensitivity of the cation exchange procedures is assessed. Radiochemical purity is the critical determinant of sensitivity for recycled assays. The cation exchange method is compared with the commonly used CO/sub 2/-trapping method. The cation exchange method is more specific and approximately three orders of magnitude more sensitive than the CO/sub 2/-trapping method. L-ornithine decarboxylase activity can be measured reliably in samples of embryonic neural tissues having wet-weights of approx. 1 ..mu..g. L-ornithine decarboxylase activity in the lumbar spinal cord of the chick embryo decreases 25-30 fold from day 5 to day 18 of embryonic development. A cation exchange procedure for estimating L-lysine decarboxylase activity is also described. Failure to detect L-lysine decarboxylase activity in the chick embryo lumbar spinal cord is contrasted with the previous report of high cadaverine levels in chick embryos.

  3. The radiometric industries of the countries of the European Community

    International Nuclear Information System (INIS)

    Roeper, Burkhardt

    1975-01-01

    The economic development of the radiometric industries in the EEC and the USA since 1960 is studied on the basis of sales statistics. The study covers the supply and the use of radioisotopes, the application of radiometric techniques, the scope and the development of the foreign trade as well as the structure of the firms concerned. The future need for radiometric apparatus is estimated as regards radiation protection, laboratories, industry, nuclear power plants and medicine

  4. Ergonomics for enhancing detection of machine abnormalities.

    Science.gov (United States)

    Illankoon, Prasanna; Abeysekera, John; Singh, Sarbjeet

    2016-10-17

    Detecting abnormal machine conditions is of great importance in an autonomous maintenance environment. Ergonomic aspects can be invaluable when detection of machine abnormalities using human senses is examined. This research outlines the ergonomic issues involved in detecting machine abnormalities and suggests how ergonomics would improve such detections. Cognitive Task Analysis was performed in a plant in Sri Lanka where Total Productive Maintenance is being implemented to identify sensory types that would be used to detect machine abnormalities and relevant Ergonomic characteristics. As the outcome of this research, a methodology comprising of an Ergonomic Gap Analysis Matrix for machine abnormality detection is presented.

  5. Application of silver nanoparticles in the detection of SYBR Green I by surface enhanced Raman and surface-enhanced fluorescence

    Science.gov (United States)

    Guo, Wei; Wu, Jian; Wang, Chunyan; Zhang, Tian; Chen, Tao

    2018-05-01

    Silver nanomaterials have remarkable application in biomedical detection due to their unique surface plasmon resonance (SPR) characteristics. It can be used for surface-enhanced Raman scattering (SERS) and surface-enhanced fluorescence (SEF). Current research elaborates a technique for improvement of SYBR Green I detection obtained from surface-enhanced Raman scattering (SERS) and surface-enhanced fluorescence (SEF) by silver nanoparticles with the average size about 70 nm. Primarily, SYBR Green I is an important fluorescent dye used in polymerase chain reaction (PCR). It is found that both Raman and fluorescence can be used for detection of this dye. Furthermore, the enhanced efficiency of the Raman and fluorescence by SERS and SEF is observed in this study, the enhancement factor for Raman signals is 3.2 × 103, and the fluorescence intensity bincreased two times by SEF. The quantitative detection of SYBR Green I by SERS and SEF can be achieved. The present work can be used to improve the detection of SYBR Green I by SERS and SEF. It would also be employed for high-sensitive detection of other materials in the future.

  6. Amalgamation of Anomaly-Detection Indices for Enhanced Process Monitoring

    KAUST Repository

    Harrou, Fouzi; Sun, Ying; Khadraoui, Sofiane

    2016-01-01

    Accurate and effective anomaly detection and diagnosis of modern industrial systems are crucial for ensuring reliability and safety and for maintaining desired product quality. Anomaly detection based on principal component analysis (PCA) has been

  7. Optical Imaging and Radiometric Modeling and Simulation

    Science.gov (United States)

    Ha, Kong Q.; Fitzmaurice, Michael W.; Moiser, Gary E.; Howard, Joseph M.; Le, Chi M.

    2010-01-01

    OPTOOL software is a general-purpose optical systems analysis tool that was developed to offer a solution to problems associated with computational programs written for the James Webb Space Telescope optical system. It integrates existing routines into coherent processes, and provides a structure with reusable capabilities that allow additional processes to be quickly developed and integrated. It has an extensive graphical user interface, which makes the tool more intuitive and friendly. OPTOOL is implemented using MATLAB with a Fourier optics-based approach for point spread function (PSF) calculations. It features parametric and Monte Carlo simulation capabilities, and uses a direct integration calculation to permit high spatial sampling of the PSF. Exit pupil optical path difference (OPD) maps can be generated using combinations of Zernike polynomials or shaped power spectral densities. The graphical user interface allows rapid creation of arbitrary pupil geometries, and entry of all other modeling parameters to support basic imaging and radiometric analyses. OPTOOL provides the capability to generate wavefront-error (WFE) maps for arbitrary grid sizes. These maps are 2D arrays containing digital sampled versions of functions ranging from Zernike polynomials to combination of sinusoidal wave functions in 2D, to functions generated from a spatial frequency power spectral distribution (PSD). It also can generate optical transfer functions (OTFs), which are incorporated into the PSF calculation. The user can specify radiometrics for the target and sky background, and key performance parameters for the instrument s focal plane array (FPA). This radiometric and detector model setup is fairly extensive, and includes parameters such as zodiacal background, thermal emission noise, read noise, and dark current. The setup also includes target spectral energy distribution as a function of wavelength for polychromatic sources, detector pixel size, and the FPA s charge

  8. Detection of breast abnormalities on enhanced chest CT: Correlation with breast composition on mammography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eun Mi; Kang, Hee; Shin, Young Gyung; Yun, Jong Hyouk; Oh, Kyung Seung [Dept. of Radiology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan (Korea, Republic of)

    2017-02-15

    To investigate the capability of enhanced chest computed tomography (CT) for detecting breast abnormalities and to assess the influence of breast composition on this detectability. From 2000 to 2013, 75 patients who underwent mammography, breast sonography, and enhanced chest CT within one month and had abnormalities on sonography were included. Detection rate of breast abnormality on enhanced chest CT was compared among 4 types of breast composition by the Breast Imaging Reporting and Data System. Contribution of breast composition, size and enhancement of target lesions to detectability of enhanced chest CT was assessed using logistic regression and chi-square test. Of the 75 target lesions, 34 (45.3%) were detected on enhanced chest CT, corresponding with those on breast sonography; there were no significantly different detection rates among the 4 types of breast composition (p = 0.078). Breast composition [odds ratio (OR) = 1.07, p = 0.206] and enhancement (OR = 21.49, p = 0.998) had no significant effect, but size (OR = 1.23, p = 0.004) was a significant contributing factor influencing the detectability of enhanced chest CT for breast lesions. About half of the cases (45.3%) demonstrated breast lesions on chest CT corresponding with target lesions on sonography. Breast composition defined on mammography did not affect the detectability of enhanced chest CT for breast lesions.

  9. Radiometric survey in sampling areas of Itataia mine ore and radiometric monitoring in Itataia project sites

    International Nuclear Information System (INIS)

    1982-07-01

    This radiometric survey was done by CDTN, in Itataia sites, on July/82 and it aimed fundamentally to evaluate local radiological conditions, as for aspect of occupational radiation protection. Besides of results obtained, this report has informations of general aspects that ought to serve as subsidies for elaboration of radiological protection program of local. (author) [pt

  10. Enhancement of optic cup detection through an improved vessel kink detection framework

    Science.gov (United States)

    Wong, Damon W. K.; Liu, Jiang; Tan, Ngan Meng; Zhang, Zhuo; Lu, Shijian; Lim, Joo Hwee; Li, Huiqi; Wong, Tien Yin

    2010-03-01

    Glaucoma is a leading cause of blindness. The presence and extent of progression of glaucoma can be determined if the optic cup can be accurately segmented from retinal images. In this paper, we present a framework which improves the detection of the optic cup. First, a region of interest is obtained from the retinal fundus image, and a pallor-based preliminary cup contour estimate is determined. Patches are then extracted from the ROI along this contour. To improve the usability of the patches, adaptive methods are introduced to ensure the patches are within the optic disc and to minimize redundant information. The patches are then analyzed for vessels by an edge transform which generates pixel segments of likely vessel candidates. Wavelet, color and gradient information are used as input features for a SVM model to classify the candidates as vessel or non-vessel. Subsequently, a rigourous non-parametric method is adopted in which a bi-stage multi-resolution approach is used to probe and localize the location of kinks along the vessels. Finally, contenxtual information is used to fuse pallor and kink information to obtain an enhanced optic cup segmentation. Using a batch of 21 images obtained from the Singapore Eye Research Institute, the new method results in a 12.64% reduction in the average overlap error against a pallor only cup, indicating viable improvements in the segmentation and supporting the use of kinks for optic cup detection.

  11. Gray-scale contrast-enhanced utrasonography in detecting sentinel lymph nodes: An animal study

    International Nuclear Information System (INIS)

    Wang Yuexiang; Cheng Zhigang; Li Junlai; Tang Jie

    2010-01-01

    Objective: To investigate the usefulness of gray-scale contrast-enhanced ultrasonography for detecting sentinel lymph nodes. Methods: Contrast-enhanced ultrasonography was performed in five normal dogs (four female and one male) after subcutaneous administration of a sonographic contrast agent (Sonovue, Bracco, Milan, Italy). Four distinct regions in each animal were examined. After contrast-enhanced ultrasonography, 0.8 ml of blue dye was injected into the same location as Sonovue and the sentinel lymph nodes were detected by surgical dissection. The findings of contrast-enhanced ultrasonography were compared with those of the blue dye. Results: Twenty-one sentinel lymph nodes were detected by contrast-enhanced ultrasonography while 23 were identified by blue dye with surgical dissection. Compared with the blue dye, the detection rate of enhanced ultrasonography for the sentinel lymph nodes is 91.3% (21/23). Two patterns of enhancement in the sentinel lymph nodes were observed: complete enhancement (5 sentinel lymph nodes) and partial enhancement (16 sentinel lymph nodes). The lymphatic channels were demonstrated as hyperechoic linear structures leading from the injection site and could be readily followed to their sentinel lymph nodes. Histopathologic examination showed proliferation of lymphatic follicles or lymphatic sinus in partial enhanced sentinel lymph nodes while normal lymphatic tissue was demonstrated in completely enhanced sentinel lymph nodes. Conclusions: Sonovue combined with gray-scale contrast-enhanced ultrasonography may provide a feasible method for detecting sentinel lymph nodes.

  12. Radiometric measurement independent of profile. Belt weighers

    International Nuclear Information System (INIS)

    Otto, J.

    1986-01-01

    Radiometric measuring techniques allow contactless determination of the material carried by belt conveyors. Data defining the material is obtained via attenuation of gamma rays passing through the material on the belt. The method applies the absorption law according to Lambert-Beer, which has to be corrected by a build-up factor because of the stray radiation induced by the Compton effect. The profile-dependent error observed with conventional radiometric belt weighers is caused by the non-linearity of the absorption law in connection with the simultaneous summation of the various partial rays in a detector. The scanning method allows separate evaluation of the partial rays' attenuation and thus yields the correct data of the material carried, regardless of the profile. The scanning method is applied on a finite number of scanning sections, and a residual error has to be taken into account. The stochastics of quantum emission and absorption leads to an error whose expectation value is to be taken into account in the scanning algorithm. As the conveyor belt is in motion during the process of measurements, only part of the material conveyed is irradiated. The resulting assessment error is investigated as a function of the autocorrelation function of the material on the belt. (orig./HP) [de

  13. Application of microcomputer to X-ray radiometric ore separation

    International Nuclear Information System (INIS)

    Neverov, A.D.; Aleksandrov, P.S.; Kotler, N.I.

    1988-01-01

    The practical use of microcomputers as universal means for converting information for solving applied problems of X-ray radiometric ore separation method is considered. Laboratory tests of two metals - tungsten and tin manifested high efficiency of the developed system. X-ray radiometric separator software is developed

  14. Tasmanian tin and tungsten granites - their radiometric characteristics

    International Nuclear Information System (INIS)

    Yeates, A.N.

    1982-01-01

    A radiometric survey of Tasmanian granites has shown, with one exception, that tin and tungsten-bearing granites have high radioactivity, largely owing to increased uranium. Many have a high uranium/thorium ratio as well. Radiometric measurements can also delineate different granite types within composite bodies

  15. A simple radiometric in vitro assay for acetylcholinesterase inhibitors

    International Nuclear Information System (INIS)

    Guilarte, T.R.; Burns, H.D.; Dannals, R.F.; Wagner, H.N. Jr.

    1983-01-01

    A radiometric method for screening acetylcholinesterase inhibitors has been described. The method is based on the production of [ 14 C]carbon dioxide from the hydrolysis of acetylcholine. The inhibitory concentration at 50% (IC50) values for several known acetylcholinesterase inhibitors were in agreement with literature values. The new radiometric method is simple, inexpensive, and has the potential for automation

  16. New age radiometric ore sorting - the elegant solution

    International Nuclear Information System (INIS)

    Gordon, H.P.; Heuer, T.

    2000-01-01

    Radiometric ore sorting technology and application are described in two parts. Part I reviews the history of radiometric sorting in the minerals industry and describes the latest developments in radiometric sorting technology. Part II describes the history, feasibility study and approach used in the application of the new technology at Rossing Uranium Limited. There has been little progress in the field of radiometric sorting since the late 1970s. This has changed with the development of a high capacity radiometric sorter designed to operate on low-grade ore in the +75mm / -300mm size fraction. This has been designed specifically for an application at Rossing. Rossing has a long history in radiometric sorting dating back to 1968 when initial tests were conducted on the Rossing prospect. Past feasibility studies concluded that radiometric sorting would not conclusively reduce the unit cost of production unless sorting was used to increase production levels. The current feasibility study shows that the application of new radiometric sorter technology makes sorting viable without increasing production, and significantly more attractive with increased production. A pilot approach to confirm sorter performance is described. (author)

  17. Field radiometric methods of prospecting and exploration for uranium ores

    International Nuclear Information System (INIS)

    Gorbushina, L.V.; Savenko, E.I.; Serdyukova, A.S.

    1978-01-01

    The textbook includes two main chapters which describe gamma- and emanation field radiometric methods. The textbook is intended for geology and geophysics students having training practice in field radiometric methods and is additional to the course of lectures. The textbook can be used in the''Radiometry'' course which is studied in appropriate geological and technical colleges

  18. Local correlation detection with linearity enhancement in streaming data

    KAUST Repository

    Xie, Qing; Shang, Shuo; Yuan, Bo; Pang, Chaoyi; Zhang, Xiangliang

    2013-01-01

    -correlation calculation with time delay allowed. In addition, we introduce a shape-based similarity measure into the framework, which ref nes the results by representative trend patterns to enhance the signif cance of linearity. The similarity of proposed linear

  19. Enhancing community detection by using local structural information

    International Nuclear Information System (INIS)

    Xiang, Ju; Bao, Mei-Hua; Tang, Liang; Li, Jian-Ming; Hu, Ke; Chen, Benyan; Hu, Jing-Bo; Zhang, Yan; Tang, Yan-Ni; Gao, Yuan-Yuan

    2016-01-01

    Many real-world networks, such as gene networks, protein–protein interaction networks and metabolic networks, exhibit community structures, meaning the existence of groups of densely connected vertices in the networks. Many local similarity measures in the networks are closely related to the concept of the community structures, and may have a positive effect on community detection in the networks. Here, various local similarity measures are used to extract local structural information, which is then applied to community detection in the networks by using the edge-reweighting strategy. The effect of the local similarity measures on community detection is carefully investigated and compared in various networks. The experimental results show that the local similarity measures are crucial for the improvement of community detection methods, while the positive effect of the local similarity measures is closely related to the networks under study and applied community detection methods. (paper: interdisciplinary statistical mechanics)

  20. Radiometric detection in flow-injection analysis; Radiometric flow-injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Han, B; Myoe, K M; Kywe, A; Thida, [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Braatislava (Slovakia). Dept. of Environmental Science

    1994-05-17

    A single line system with a detector of radioactivity was used for the determination of [sup 60]Co. In the determination, no additional chemistry is involved and limited dispersion is desirable. For this application, the FIA system is used only as a transport system for the sample up to the detector. (author) 7 refs.; 4 figs.

  1. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  2. kCCA Transformation-Based Radiometric Normalization of Multi-Temporal Satellite Images

    Directory of Open Access Journals (Sweden)

    Yang Bai

    2018-03-01

    Full Text Available Radiation normalization is an essential pre-processing step for generating high-quality satellite sequence images. However, most radiometric normalization methods are linear, and they cannot eliminate the regular nonlinear spectral differences. Here we introduce the well-established kernel canonical correlation analysis (kCCA into radiometric normalization for the first time to overcome this problem, which leads to a new kernel method. It can maximally reduce the image differences among multi-temporal images regardless of the imaging conditions and the reflectivity difference. It also perfectly eliminates the impact of nonlinear changes caused by seasonal variation of natural objects. Comparisons with the multivariate alteration detection (CCA-based normalization and the histogram matching, on Gaofen-1 (GF-1 data, indicate that the kCCA-based normalization can preserve more similarity and better correlation between an image-pair and effectively avoid the color error propagation. The proposed method not only builds the common scale or reference to make the radiometric consistency among GF-1 image sequences, but also highlights the interesting spectral changes while eliminates less interesting spectral changes. Our method enables the application of GF-1 data for change detection, land-use, land-cover change detection etc.

  3. Enhancing Syndromic Surveillance With Online Respondent-Driven Detection

    NARCIS (Netherlands)

    Stein, Mart L; van Steenbergen, Jim E; Buskens, Vincent; van der Heijden, Peter G M; Koppeschaar, Carl E; Bengtsson, Linus; Thorson, Anna; Kretzschmar, MEE

    OBJECTIVES: We investigated the feasibility of combining an online chain recruitment method (respondent-driven detection) and participatory surveillance panels to collect previously undetected information on infectious diseases via social networks of participants. METHODS: In 2014, volunteers from 2

  4. Enhancing syndromic surveillance with online respondent-driven detection

    NARCIS (Netherlands)

    Stein, Mart L.; Van Steenbergen, Jim E.; Buskens, Vincent; Van Der Heijden, Peter G M; Koppeschaar, Carl E.; Bengtsson, Linus; Thorson, Anna; Kretzschmar, Mirjam E E

    2015-01-01

    Objectives. We investigated the feasibility of combining an online chain recruitment method (respondent-driven detection) and participatory surveillance panels to collect previously undetected information on infectious diseases via social networks of participants. Methods. In 2014, volunteers from 2

  5. Enhancing Community Detection By Affinity-based Edge Weighting Scheme

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Andy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sanders, Geoffrey [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Henson, Van [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Vassilevski, Panayot [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-10-05

    Community detection refers to an important graph analytics problem of finding a set of densely-connected subgraphs in a graph and has gained a great deal of interest recently. The performance of current community detection algorithms is limited by an inherent constraint of unweighted graphs that offer very little information on their internal community structures. In this paper, we propose a new scheme to address this issue that weights the edges in a given graph based on recently proposed vertex affinity. The vertex affinity quantifies the proximity between two vertices in terms of their clustering strength, and therefore, it is ideal for graph analytics applications such as community detection. We also demonstrate that the affinity-based edge weighting scheme can improve the performance of community detection algorithms significantly.

  6. Automatic and improved radiometric correction of Landsat imagery using reference values from MODIS surface reflectance images

    Science.gov (United States)

    Pons, X.; Pesquer, L.; Cristóbal, J.; González-Guerrero, O.

    2014-12-01

    Radiometric correction is a prerequisite for generating high-quality scientific data, making it possible to discriminate between product artefacts and real changes in Earth processes as well as accurately produce land cover maps and detect changes. This work contributes to the automatic generation of surface reflectance products for Landsat satellite series. Surface reflectances are generated by a new approach developed from a previous simplified radiometric (atmospheric + topographic) correction model. The proposed model keeps the core of the old model (incidence angles and cast-shadows through a digital elevation model [DEM], Earth-Sun distance, etc.) and adds new characteristics to enhance and automatize ground reflectance retrieval. The new model includes the following new features: (1) A fitting model based on reference values from pseudoinvariant areas that have been automatically extracted from existing reflectance products (Terra MODIS MOD09GA) that were selected also automatically by applying quality criteria that include a geostatistical pattern model. This guarantees the consistency of the internal and external series, making it unnecessary to provide extra atmospheric data for the acquisition date and time, dark objects or dense vegetation. (2) A spatial model for atmospheric optical depth that uses detailed DEM and MODTRAN simulations. (3) It is designed so that large time-series of images can be processed automatically to produce consistent Landsat surface reflectance time-series. (4) The approach can handle most images, acquired now or in the past, regardless of the processing system, with the exception of those with extremely high cloud coverage. The new methodology has been successfully applied to a series of near 300 images of the same area including MSS, TM and ETM+ imagery as well as to different formats and processing systems (LPGS and NLAPS from the USGS; CEOS from ESA) for different degrees of cloud coverage (up to 60%) and SLC

  7. Stochastic Resonance algorithms to enhance damage detection in bearing faults

    OpenAIRE

    Castiglione Roberto; Garibaldi Luigi; Marchesiello Stefano

    2015-01-01

    Stochastic Resonance is a phenomenon, studied and mainly exploited in telecommunication, which permits the amplification and detection of weak signals by the assistance of noise. The first papers on this technique are dated early 80 s and were developed to explain the periodically recurrent ice ages. Other applications mainly concern neuroscience, biology, medicine and obviously signal analysis and processing. Recently, some researchers have applied the technique for detecting faults in mecha...

  8. Amalgamation of Anomaly-Detection Indices for Enhanced Process Monitoring

    KAUST Repository

    Harrou, Fouzi

    2016-01-29

    Accurate and effective anomaly detection and diagnosis of modern industrial systems are crucial for ensuring reliability and safety and for maintaining desired product quality. Anomaly detection based on principal component analysis (PCA) has been studied intensively and largely applied to multivariate processes with highly cross-correlated process variables; howver conventional PCA-based methods often fail to detect small or moderate anomalies. In this paper, the proposed approach integrates two popular process-monitoring detection tools, the conventional PCA-based monitoring indices Hotelling’s T2 and Q and the exponentially weighted moving average (EWMA). We develop two EWMA tools based on the Q and T2 statistics, T2-EWMA and Q-EWMA, to detect anomalies in the process mean. The performances of the proposed methods were compared with that of conventional PCA-based anomaly-detection methods by applying each method to two examples: a synthetic data set and experimental data collected from a flow heating system. The results clearly show the benefits and effectiveness of the proposed methods over conventional PCA-based methods.

  9. Multi-metal, Multi-wavelength Surface-Enhanced Raman Spectroscopy Detection of Neurotransmitters.

    Science.gov (United States)

    Moody, Amber S; Sharma, Bhavya

    2018-04-05

    The development of a sensor for the rapid and sensitive detection of neurotransmitters could provide a pathway for the diagnosis of neurological diseases, leading to the discovery of more effective treatment methods. We investigate the use of surface enhanced Raman spectroscopy (SERS) based sensors for the rapid detection of melatonin, serotonin, glutamate, dopamine, GABA, norepinephrine, and epinephrine. Previous studies have demonstrated SERS detection of neurotransmitters; however, there has been no comprehensive study on the effect of the metal used as the SERS substrate or the excitation wavelength used for detection. Here, we present the detection of 7 neurotransmitters using both silver and gold nanoparticles at excitation wavelengths of 532, 633, and 785 nm. Over the range of wavelengths investigated, the SERS enhancement on the silver and gold nanoparticles varies, with an average enhancement factor of 10 5 -10 6 . The maximum SERS enhancement occurs at an excitation wavelength of 785 nm for the gold nanoparticles and at 633 nm for the silver nanoparticles.

  10. Impact of the cameras radiometric resolution on the accuracy of determining spectral reflectance coefficients

    Science.gov (United States)

    Orych, A.; Walczykowski, P.; Jenerowicz, A.; Zdunek, Z.

    2014-11-01

    Nowadays remote sensing plays a very important role in many different study fields, i.e. environmental studies, hydrology, mineralogy, ecosystem studies, etc. One of the key areas of remote sensing applications is water quality monitoring. Understanding and monitoring of the water quality parameters and detecting different water contaminants is an important issue in water management and protection of whole environment and especially the water ecosystem. There are many remote sensing methods to monitor water quality and detect water pollutants. One of the most widely used method for substance detection with remote sensing techniques is based on usage of spectral reflectance coefficients. They are usually acquired using discrete methods such as spectrometric measurements. These however can be very time consuming, therefore image-based methods are used more and more often. In order to work out the proper methodology of obtaining spectral reflectance coefficients from hyperspectral and multispectral images, it is necessary to verify the impact of cameras radiometric resolution on the accuracy of determination of them. This paper presents laboratory experiments that were conducted using two monochromatic XEVA video sensors (400-1700 nm spectral data registration) with two different radiometric resolutions (12 and 14 bits). In view of determining spectral characteristics from images, the research team used set of interferometric filters. All data collected with multispectral digital video cameras were compared with spectral reflectance coefficients obtained with spectroradiometer. The objective of this research is to find the impact of cameras radiometric resolution on reflectance values in chosen wavelength. The main topic of this study is the analysis of accuracy of spectral coefficients from sensors with different radiometric resolution. By comparing values collected from images acquired with XEVA sensors and with the curves obtained with spectroradiometer it

  11. A new semiquantitative radiometric opsonin assay

    International Nuclear Information System (INIS)

    Yamamura, M.; Valdimarsson, H.

    1978-01-01

    A new semiquantitative radiometric opsonin assay is described. It was found that the opsonin activity generated by incubating brewer's yeast, Saccharomyces cerevisiae, in medium containing less than 5% human serum was exclusively complement dependent. In contrast, C.albicans was effectively opsonized in the absence of complement. Antibodies and the early classical complement pathway did not contribute to the opsonization of S.cerevisiae and neither did C5-9. The brewer's yeast assay can therefore be used for measuring selectively the opsonizing capacity of the alternative pathway. Sera from approximately 7% of apparently healthy adult controls consistently failed to generate significant opsonin activity while 8 out of 26 patients with suspected immune deficiency of unknown cause were defective in this assay. All opsonin deficient sera so far tested had haemolytically normal alternative pathway and Factor B activity. (author)

  12. Radiometric sorting of Rio Algom uranium ore

    International Nuclear Information System (INIS)

    Cristovici, M.A.

    1983-11-01

    An ore sample of about 0.2 percent uranium from Quirke Mine was subjected to radiometric sorting by Ore Sorters Limited. Approximately 60 percent of the sample weight fell within the sortable size range: -150 + 25 mm. Rejects of low uranium content ( 2 (2 counts/in 2 ) but only 7.6 percent of the ore, by weight, was discarded. At 0.8-0.9 counts/cm 2 (5-6 counts/in 2 ) a significant amount of rejects was removed (> 25 percent) but the uranium loss was unacceptably high (7.7 percent). Continuation of the testwork to improve the results is proposed by trying to extend the sortable size range and to reduce the amount of fines during crushing

  13. Importance of radiometric survey in radiodiagnosis installationscalculated

    International Nuclear Information System (INIS)

    Leyton, Fernando; Alarcon, Luis; Zapata, Victor H.; Ortega, Dulia; Ramirez, Alfredo; Aravena, Gonzalo; Ubeda, Carlos; Oyarzun, Carlos; Inzulza, Alonso

    2005-01-01

    A radiometric survey was conducted in two services of imaging with a total of 7 evaluated radiology rooms. The Quality Control Protocol methodology was used in Radiology ARCAL (Regional Agreement of cooperation for the promotion of nuclear science and technology in Latin America and the Caribbean) XLIX of the International Atomic Energy Agency (IAEA). The effective dose in different positions of interest rates were calculated, from the point of view of radiation protection. All evaluated rooms have rates of effective doses that meet the values limits set in the Protocol ARCAL XLIX, for 82% of the positions evaluated. However operators located in the position A (controlled area) exceed on average 370% with a range of [1-870] the limit proposed by ARCAL XLIX

  14. Radiometric monitoring outdoor municipality Pocinhos-PB

    International Nuclear Information System (INIS)

    Cardinalli Araujo Costa, Michelle; Araujo dos Santos Junior, Jose; Dos Santos Amaral, Romilton

    2015-01-01

    Studies on human exposure to terrestrial radionuclides are important for human health. Therefore, this investigation presents aimed at making radiometric dosimetry Pocinhos municipality in the state of Paraiba. Monitoring was performed in 50 points in urban and rural areas Pocinhos. The estimated external effective dose rate in outdoor environments was obtained in triplicate using a portable gamma spectrometer, to 1.0 m away from the Earth's surface and time set acquisition in terms of environmental radiation levels. The values of these dose rates outdoor environments ranging from 0.53 to 3.94 mSv.y -1 . the arithmetic mean was 0.79 mSv.y -1 , which exceeds the value 0.07 mSv.y -1 corresponding to the global average in outdoor environments. In the city, found a higher radioactivity in rural areas that were uninhabited at the time of the survey. (Author)

  15. Enhanced chemosensory detection of negative emotions in congenital blindness

    DEFF Research Database (Denmark)

    Iversen, Katrine D.; Ptito, Maurice; Møller, Per

    2015-01-01

    blind and normal sighted individuals in their ability to discriminate and identify emotions from body odours. A group of 14 congenitally blind and 14 age- and sex-matched sighted control subjects participated in the study. We compared participants' abilities to detect and identify by smelling sweat from...

  16. Enhanced detection levels in a semi-automated sandwich ...

    African Journals Online (AJOL)

    A peptide nucleic acid (PNA) signal probe was tested as a replacement for a typical DNA oligonucleotidebased signal probe in a semi-automated sandwich hybridisation assay designed to detect the harmful phytoplankton species Alexandrium tamarense. The PNA probe yielded consistently higher fluorescent signal ...

  17. Comparison of AMI-25 enhanced MRI and helical dynamic CT in the detection of hepatic lesions

    International Nuclear Information System (INIS)

    Saitou, Kazuhiro; Matsuda, Hiromichi; Fukushima, Hiroaki; Kanzaki, Hiroshi; Hirose, Takashi; Karizaki, Dai; Abe, Kimihiko; Amino, Saburou

    1994-01-01

    We performed AMI-25 enhanced MRI and helical dynamic CT in 12 cases of hepatic lesions. Nine of these were hepatocellular carcinomas. Two cases were metastatic liver tumors (the primary lesion was gastric in one and the other was gallbladder cancer). One case was suspected to be adenomatous hyperplasia. Thirty-two lesions were detected in T2-weighted SE images before AMI-25 administration, while 46 lesions were detected in AMI-25 enhanced MRI images. In particular, AMI-25 enhanced MRI was superior to plain MRI in lesions less than 10 mm in size. A total of 48 lesions were detected in helical dynamic CT. Although AMI-25 enhanced MRI almost equaled helical dynamic CT in the detection of liver tumors, helical dynamic CT was slightly superior to AMI-25 enhanced MRI in the detection of subphrenic lesions. It was possible to know the hemodynamics in each hepatic lesion by helical dynamic CT. AMI-25 enhanced MRI was useful to know the inclusion of reticuloendothelial system, and that yielded different diagnoses in adenomatous hyperplasia and well differentiated hepatocellular carcinoma. Helical dynamic CT was useful for qualitative diagnosis. Both AMI-25 enhanced MRI and helical dynamic CT contributed to the detection of liver tumor and qualitative diagnosis. (author)

  18. An equivalent method of mixed dielectric constant in passive microwave/millimeter radiometric measurement

    Science.gov (United States)

    Su, Jinlong; Tian, Yan; Hu, Fei; Gui, Liangqi; Cheng, Yayun; Peng, Xiaohui

    2017-10-01

    Dielectric constant is an important role to describe the properties of matter. This paper proposes This paper proposes the concept of mixed dielectric constant(MDC) in passive microwave radiometric measurement. In addition, a MDC inversion method is come up, Ratio of Angle-Polarization Difference(RAPD) is utilized in this method. The MDC of several materials are investigated using RAPD. Brightness temperatures(TBs) which calculated by MDC and original dielectric constant are compared. Random errors are added to the simulation to test the robustness of the algorithm. Keywords: Passive detection, microwave/millimeter, radiometric measurement, ratio of angle-polarization difference (RAPD), mixed dielectric constant (MDC), brightness temperatures, remote sensing, target recognition.

  19. Mississippi exploration field trials using microbial, radiometrics, free soil gas, and other techniques

    Energy Technology Data Exchange (ETDEWEB)

    Moody, J.S.; Brown, L.R.; Thieling, S.C.

    1995-12-31

    The Mississippi Office of Geology has conducted field trials using the surface exploration techniques of geomicrobial, radiometrics, and free soil gas. The objective of these trials is to determine if Mississippi oil and gas fields have surface hydrocarbon expression resulting from vertical microseepage migration. Six fields have been surveyed ranging in depth from 3,330 ft to 18,500 ft. The fields differ in trapping styles and hydrocarbon type. The results so far indicate that these fields do have a surface expression and that geomicrobial analysis as well as radiometrics and free soil gas can detect hydrocarbon microseepage from pressurized reservoirs. All three exploration techniques located the reservoirs independent of depth, hydrocarbon type, or trapping style.

  20. Synoptic view of the different domains of application of airborne radiometric and spectrometric surveys in egypt

    International Nuclear Information System (INIS)

    Fouad, K.M.

    1998-01-01

    Airborne radiometric survey has been applied for more than three decades in egypt. Experience gained from the acquired data over different geological environments has revealed the importance of this geophysical tool in: 1. disclosure of anomalies of potential uranium deposits, 2. geological mapping, 3. environmental monitoring of natural radiometric background around nuclear facilities, as well as the detection of nuclear fallout resulting from local or foreign nuclear activities. The advent of recording of the discriminated gamma ray energies in the airborne 256-channel spectrometer has eventually resulted in the quantitative detection of uranium, thorium, and potassium and their elemental ratios in the rocks. This has greatly widened the scope of geophysical and geochemical application. When this type is coupled with airborne magnetometry, the geological and structural configuration is appreciably revealed in three dimensions. The important role played by the statistical method of analysis is also shown. Case histories from the eastern desert, and sinai peninsula, are exhibited to help manifest the wide variety of applications of radiometric and spectrometric surveys

  1. Enhancing international radiation/nuclear detection training opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Thomas L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bersell, Bridget M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Booker, Paul M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Anderson, Gerald E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Leitch, Rosalyn M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Meagher, John B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Siefken, Rob R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spracklen, James L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-23

    The United States has worked domestically to develop and provide radiological and nuclear detection training and education initiatives aimed at interior law enforcement, but the international community has predominantly focused efforts at border and customs officials. The interior law enforcement officials of a State play a critical role in maintaining an effective national-level nuclear detection architecture. To meet this vital need, DNDO was funded by the U.S. Department of State (DOS) to create and deliver a 1-week course at the International Law Enforcement Academy (ILEA) in Budapest, Hungary to inform interior law enforcement personnel of the overall mission, and to provide an understanding of how the participants can combat the threats of radiological and nuclear terrorism through detection efforts. Two courses, with approximately 20 students in each course, were delivered in fiscal year (FY) 2013, two were delivered in FY 2014 and FY 2015, and as of this report’s writing more are planned in FY 2016. However, while the ILEA courses produced measurable success, DNDO requested Pacific Northwest National Laboratory (PNNL) research potential avenues to further increase the course impact.In a multi-phased approach, PNNL researched and analyzed several possible global training locations and venues, and other possible ways to increase the impact of the course using an agreed-to data-gathering format.

  2. Enhancing detection sensitivity of SST-1 Thomson scattering experiment

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhari, Vishnu; Patel, Kiran; Thomas, Jinto; Kumar, Ajai, E-mail: ajai@ipr.res.in

    2016-10-15

    Thomson Scattering System (TSS) is the main diagnostic to extract electron temperature and density of steady state superconducting (SST-1) tokamak plasma. Silicon avalanche photo diode is used with low noise and fast signal conditioning electronics (SCE) to detect incoming Thomson scattered laser photons. A stringent requirement for the measurement is to detect high speed and low level light signal (detection of 100 numbers of Thomson scattered photons for 50 ns pulse width at input of active area of detector) in the presence of wide band electro-magnetic interference (EMI) noise. The electronics and instruments for different sub-systems kept in laboratory contribute to the radiated and conductive noise in a complex manner to the experiment, which can degrade the resultant signal to noise ratio (SNR <1). In general a repeated trial method with flexible grounding scheme are used to improve system signal to noise ratio, which is time consuming and less efficient. In the present work a simple, robust, cost-effective instrumentation system is used for the measurement and monitoring with improved ground scheme and shielding method to minimize noise, isolating the internal sub-system generated noise and external interference which leads to an improved SNR.

  3. Carbon nanopillars for enhanced stem cell differentiation and dopamine detection

    DEFF Research Database (Denmark)

    Bunea, Ada-Ioana; Amato, Letizia; Valsesia, Andrea

    of human neural stem cells (hNSCs) into dopaminergic neurons and that they can also be employed for detecting dopamine release from mature neurons attached to them [1]. Here, we report 3D carbon nanopillars, fabricated through colloidal lithography, with even more pronounced effect on the electrochemical......Parkinson’s disease is characterized by a deficit of dopamine in the brain, a neurotransmitter involved in the motor function. One of the future ideas for treatment is cell replacement therapy. Our group has previously shown that pyrolysed 3D carbon micropillars induce spontaneous differentiation...

  4. Data acquisition and processing - helicopter radiometric survey, Krageroe, 1998

    CERN Document Server

    Beard, L P

    2000-01-01

    On 07 October 1998 a helicopter radiometric survey was flown in the vicinity of Krageroe municipality. The purpose of the survey was to provide radiometric information to help assess radon hazard from radioactive rocks in the area. A total of 60 line-kilometres of radiometric data were acquired in a single flight, covering an area of approximately 3 square km with a 50-m line spacing. The data were collected by Geological Survey of Norway (NGU) personnel and processed at NGU. Radiometric data were reduced using the three-channel procedure recommended by the International Atomic Energy Association. All data were gridded using square cells with 30-m sides and geophysical maps were produced at a scale of 1:5000. This report covers aspects of data acquisition and processing (Author)

  5. Radiometric dating by alpha spectrometry on uranium series nuclides

    NARCIS (Netherlands)

    Wijk, Albert van der

    1987-01-01

    De Engelse titel van dit proegschrift \\"Radiometric Dating by Alpha Spectometry on Uranium Series Nuclides\\" kan in het Nederlands wellicht het best worden weergegeven door \\"ouderdomsdbepalingen door stralingsmeting aan kernen uit de uraniumreeks met behulp van alfaspectometrie\\". In dit laatste

  6. Radiometric flow injection analysis with an ASIA (Ismatec) analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Win, N; San, K; Han, B; Myoe, K M [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-07-01

    Radiometric Flow Injection Analysis of a radioactive ([sup 131]I) sample is described. For analysis an ASIA (Ismatec) analyzer with a NaI(Tl) scintillation detector was used. (author) 5 refs.; 3 figs.

  7. Data acquisition and processing - helicopter radiometric survey, Krageroe, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Beard, Les P.; Mogaard, John Olav

    2000-07-01

    On 07 October 1998 a helicopter radiometric survey was flown in the vicinity of Krageroe municipality. The purpose of the survey was to provide radiometric information to help assess radon hazard from radioactive rocks in the area. A total of 60 line-kilometres of radiometric data were acquired in a single flight, covering an area of approximately 3 square km with a 50-m line spacing. The data were collected by Geological Survey of Norway (NGU) personnel and processed at NGU. Radiometric data were reduced using the three-channel procedure recommended by the International Atomic Energy Association. All data were gridded using square cells with 30-m sides and geophysical maps were produced at a scale of 1:5000. This report covers aspects of data acquisition and processing (Author)

  8. Isotopically modified nanoparticles for enhanced detection in bioaccumulation studies

    Science.gov (United States)

    Misra, S.K.; Dybowska, A.; Berhanu, D.; Croteau, M.-N.; Luoma, S.N.; Boccaccini, A.R.; Valsami-Jones, E.

    2012-01-01

    This work presents results on synthesis of isotopically enriched (99% 65Cu) copper oxide nanoparticles and its application in ecotoxicological studies. 65CuO nanoparticles were synthesized as spheres (7 nm) and rods (7 ?? 40 nm). Significant differences were observed between the reactivity and dissolution of spherical and rod shaped nanoparticles. The extreme sensitivity of the stable isotope tracing technique developed in this study allowed determining Cu uptake at exposure concentrations equivalent to background Cu concentrations in freshwater systems (0.2-30 ??g/L). Without a tracer, detection of newly accumulated Cu was impossible, even at exposure concentrations surpassing some of the most contaminated water systems (>1 mg/L). ?? 2011 American Chemical Society.

  9. Detection of pericardial inflammation with late-enhancement cardiac magnetic resonance imaging: initial results

    International Nuclear Information System (INIS)

    Taylor, Andrew M.; Dymarkowski, Steven; Bogaert, Jan; Verbeken, Eric K.

    2006-01-01

    To examine the value of late-enhancement cardiac magnetic resonance imaging (MRI) for detection of pericardial inflammation. Late-enhancement cardiac MRI was performed in 16 patients with clinical suspicion of pericardial disease. Pericardial effusion, pericardial thickening and pericardial enhancement were assessed. MRI findings were compared with those of definitive pericardial histology (n=14) or microbiology (n=2). A control group of 12 patients with no clinical evidence of pericardial disease were also imaged with the same MRI protocol. Sensitivity and specificity for late-enhancement MRI detection of pericardial inflammation was of 100%. There was MRI late enhancement of the pericardial layers in all five patients with histological/microbiological evidence of inflammatory pericarditis. MRI demonstrated no pericardial thickening and no MRI late enhancement with or without a pericardial effusion in any of the five patients with histological evidence of a normal pericardium. MRI detected pericardial thickening in the absence of both pericardial effusion and late enhancement in all six patients with histological evidence of chronic fibrosing pericarditis. The 12 control subjects showed no evidence of pericardial MRI late enhancement. These findings demonstrate that MRI late enhancement can be used to visualize pericardial inflammation in patients with clinical suspicion of pericardial disease. (orig.)

  10. Formate detection by potassium permanganate for enhanced hydrogen production in Escherichia coli

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Toshinari [Artie McFerrin Department of Chemical Engineering, 220 Jack E. Brown Building, Texas A and M University, College Station, TX 77843-3122 (United States); Wood, Thomas K. [Artie McFerrin Department of Chemical Engineering, 220 Jack E. Brown Building, Texas A and M University, College Station, TX 77843-3122 (United States); Department of Biology, Texas A and M University, College Station, TX 77843-3258 (United States); Zachry Department of Civil and Environmental Engineering, Texas A and M University, College Station, TX 77843-3136 (United States)

    2008-05-15

    Mutagenesis of Escherichia coli for hydrogen production is difficult since there is no high-throughput screen. Here we describe a method for rapid detection of enhanced hydrogen production by engineered strains by detecting formate via potassium permanganate; in E. coli, hydrogen is synthesized from formate using the formate hydrogen lyase system. (author)

  11. Radiometric determination of monoethanolamine with 65ZnSo4

    International Nuclear Information System (INIS)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S.

    1984-01-01

    Determination of milligram amounts of monoethanolamine (MEA) with zinc(II) by radiometric titration is described. When MEA is added to a zinc(II) solution containing sulphate ions at 25 degC, a white solid complex is formed. The formation of this complex is employed for the radiometric determination of MEA with 65 Zn. The amount of MEA is directly proportional to the activity of the complex formed. The method is simple, rapid and accurate. (author)

  12. Complex optimization of radiometric control and measurement systems

    International Nuclear Information System (INIS)

    Onishchenko, A.M.

    1995-01-01

    Fundamentals of a new approach to increase in the accuracy of radiometric systems of control and measurements are presented in succession. Block diagram of the new concept of radiometric system optimization is provided. The approach involving radical increase in accuracy and envisages ascertaining of controlled parameter by the totality of two intelligence signals closely correlated with each other. The new concept makes use of system analysis as a unified one-piece object, permitting euristic synthesis of the system. 4 refs., 3 figs

  13. Replica Node Detection Using Enhanced Single Hop Detection with Clonal Selection Algorithm in Mobile Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    L. S. Sindhuja

    2016-01-01

    Full Text Available Security of Mobile Wireless Sensor Networks is a vital challenge as the sensor nodes are deployed in unattended environment and they are prone to various attacks. One among them is the node replication attack. In this, the physically insecure nodes are acquired by the adversary to clone them by having the same identity of the captured node, and the adversary deploys an unpredictable number of replicas throughout the network. Hence replica node detection is an important challenge in Mobile Wireless Sensor Networks. Various replica node detection techniques have been proposed to detect these replica nodes. These methods incur control overheads and the detection accuracy is low when the replica is selected as a witness node. This paper proposes to solve these issues by enhancing the Single Hop Detection (SHD method using the Clonal Selection algorithm to detect the clones by selecting the appropriate witness nodes. The advantages of the proposed method include (i increase in the detection ratio, (ii decrease in the control overhead, and (iii increase in throughput. The performance of the proposed work is measured using detection ratio, false detection ratio, packet delivery ratio, average delay, control overheads, and throughput. The implementation is done using ns-2 to exhibit the actuality of the proposed work.

  14. Relative Radiometric Normalization and Atmospheric Correction of a SPOT 5 Time Series

    Directory of Open Access Journals (Sweden)

    Matthieu Rumeau

    2008-04-01

    Full Text Available Multi-temporal images acquired at high spatial and temporal resolution are an important tool for detecting change and analyzing trends, especially in agricultural applications. However, to insure a reliable use of this kind of data, a rigorous radiometric normalization step is required. Normalization can be addressed by performing an atmospheric correction of each image in the time series. The main problem is the difficulty of obtaining an atmospheric characterization at a given acquisition date. In this paper, we investigate whether relative radiometric normalization can substitute for atmospheric correction. We develop an automatic method for relative radiometric normalization based on calculating linear regressions between unnormalized and reference images. Regressions are obtained using the reflectances of automatically selected invariant targets. We compare this method with an atmospheric correction method that uses the 6S model. The performances of both methods are compared using 18 images from of a SPOT 5 time series acquired over Reunion Island. Results obtained for a set of manually selected invariant targets show excellent agreement between the two methods in all spectral bands: values of the coefficient of determination (r² exceed 0.960, and bias magnitude values are less than 2.65. There is also a strong correlation between normalized NDVI values of sugarcane fields (r² = 0.959. Despite a relative error of 12.66% between values, very comparable NDVI patterns are observed.

  15. Enhancement of detectability by the use of coloured illumination for CT display

    International Nuclear Information System (INIS)

    Warren, R.C.; Simpson, J.

    1984-01-01

    A study has been made of the effect of coloured illumination on the detectability of both natural and artificial low-contrast signals immersed in CT noise. Enhancement of detectability relative to white light was found to be related to variations in visual acuity at different wavelengths. These results, together with previously published observations, suggest that an increase of detectability by changing viewing conditions can usually be achieved only at the expense of a reduction in resolution. (author)

  16. Enhancement of sequential zymography technique for the detection of thermophilic lipases and proteases.

    Science.gov (United States)

    Wilkesman, Jeff; Hernández, Zully; Fernández, Marleny; Contreras, Lellys M; Kurz, Liliana

    2014-05-01

    Analysis of lipases and proteases present in cell-free fractions of thermophilic Bacillus sp. cultures were performed in an enhanced sequential zymography method. After the PAGE run, the gel was electrotransferred to another polyacrylamide gel containing a mixture of glycerol tributyrate, olive oil and gelatin. After transference, this substrate-mix gel was incubated for lipase detection, until bands appeared, and later stained with CBB for protease detection. Assets are, besides detecting two enzymes on a single gel, time and material saving.

  17. Transportable high sensitivity small sample radiometric calorimeter

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-01-01

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most 238 Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size

  18. Calibrated infrared ground/air radiometric spectrometer

    Science.gov (United States)

    Silk, J. K.; Schildkraut, Elliot Robert; Bauldree, Russell S.; Goodrich, Shawn M.

    1996-06-01

    The calibrated infrared ground/air radiometric spectrometer (CIGARS) is a new high performance, multi-purpose, multi- platform Fourier transform spectrometer (FPS) sensor. It covers the waveband from 0.2 to 12 micrometer, has spectral resolution as fine as 0.3 cm-1, and records over 100 spectra per second. Two CIGARS units are being used for observations of target signatures in the air or on the ground from fixed or moving platforms, including high performance jet aircraft. In this paper we describe the characteristics and capabilities of the CIGARS sensor, which uses four interchangeable detector modules (Si, InGaAs, InSb, and HgCdTe) and two optics modules, with internal calibration. The data recording electronics support observations of transient events, even without precise information on the timing of the event. We present test and calibration data on the sensitivity, spectral resolution, stability, and spectral rate of CIGARS, and examples of in- flight observations of real targets. We also discuss plans for adapting CIGARS for imaging spectroscopy observations, with simultaneous spectral and spatial data, by replacing the existing detectors with a focal plane array (FPA).

  19. Inverting radiometric measurements with a neural network

    Science.gov (United States)

    Measure, Edward M.; Yee, Young P.; Balding, Jeff M.; Watkins, Wendell R.

    1992-02-01

    A neural network scheme for retrieving remotely sensed vertical temperature profiles was applied to observed ground based radiometer measurements. The neural network used microwave radiance measurements and surface measurements of temperature and pressure as inputs. Because the microwave radiometer is capable of measuring 4 oxygen channels at 5 different elevation angles (9, 15, 25, 40, and 90 degs), 20 microwave measurements are potentially available. Because these measurements have considerable redundancy, a neural network was experimented with, accepting as inputs microwave measurements taken at 53.88 GHz, 40 deg; 57.45 GHz, 40 deg; and 57.45, 90 deg. The primary test site was located at White Sands Missile Range (WSMR), NM. Results are compared with measurements made simultaneously with balloon borne radiosonde instruments and with radiometric temperature retrievals made using more conventional retrieval algorithms. The neural network was trained using a Widrow-Hoff delta rule procedure. Functions of date to include season dependence in the retrieval process and functions of time to include diurnal effects were used as inputs to the neural network.

  20. Detection of hepatic metastasis: Manganese- and ferucarbotran-enhanced MR imaging

    International Nuclear Information System (INIS)

    Choi, Jin-Young; Kim, Myeong-Jin; Kim, Joo Hee; Kim, Seung Hyoung; Ko, Heung-Kyu; Lim, Joon Seok; Oh, Young Taik; Chung, Jae-Joon; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang

    2006-01-01

    Purpose: To compare the mangafodipir trisodium (MnDPDP)-enhanced and ferucarbotran-enhanced magnetic resonance imaging (MRI) for the detection of hepatic metastases. Material and methods: Twenty patients with known hepatic metastasis underwent MR imaging using mangafodipir trisodium and ferucarbotran in at least 1-day intervals. Thirty-eight metastases were confirmed either histologically or clinically. Two radiologists independently reviewed the MnDPDP-enhanced and ferucarbotran-enhanced sets in a random order. The sensitivity and accuracy of lesion detection and the ability to distinguish a benign lesion from a malignant lesion were compared by the areas (Az) under the receiver operating characteristic (ROC) curve. The lesion-liver contrast-to-noise ratios (CNR) were compared by paired t-test. Results: The overall accuracy for detecting metastases was not significantly different between the MnDPDP set (Az = 0.912 and 0.913 for reader 1 and 2, respectively) and the SPIO set (Az = 0.920 and 0.950). The CNR at the MnDPDP-enhanced images and the SPIO-enhanced images were not significantly different (P = 0.146). Conclusion: Both MnDPDP- and ferucarbotran-enhanced MRI have a comparable accuracy in detecting hepatic metastasis

  1. A precise, efficient radiometric assay for bacterial growth

    International Nuclear Information System (INIS)

    Boonkitticharoen, V.; Ehrhardt, C.; Kirchner, P.T.

    1984-01-01

    The two-compartment radiometric assay for bacterial growth promised major advantages over systems in clinical use, but poor reproducibility and counting efficiency limited its application. In this method, 14-CO/sub 2/ produced by bacterial metabolism of C-14-glucose is trapped and counted on filter paper impregnated with NaOH and fluors. The authors sought to improve assay efficiency and precision through a systematic study of relevant physical and chemical factors. Improvements in efficiency (88% vs. 10%) and in precision (relative S.D. 5% vs. 40%) were produced by a) reversing growth medium and scintillator chambers to permit vigorous agitation, b) increasing NaOH quantity and using a supersaturated PPO solution and c) adding detergent to improve uniformity of NaOH-PPO mixture. Inoculum size, substrate concentration and O/sub 2/ transfer rate affected assay sensitivity but not bacterial growth rate. The authors' assay reliably detects bacterial growth for inocula of 10,000 organisms in 1 hour and for 25 organisms within 4 1/2 hours, thus surpassing other existing clinical and research methods

  2. Advanced radiometric and interferometric milimeter-wave scene simulations

    Science.gov (United States)

    Hauss, B. I.; Moffa, P. J.; Steele, W. G.; Agravante, H.; Davidheiser, R.; Samec, T.; Young, S. K.

    1993-01-01

    Smart munitions and weapons utilize various imaging sensors (including passive IR, active and passive millimeter-wave, and visible wavebands) to detect/identify targets at short standoff ranges and in varied terrain backgrounds. In order to design and evaluate these sensors under a variety of conditions, a high-fidelity scene simulation capability is necessary. Such a capability for passive millimeter-wave scene simulation exists at TRW. TRW's Advanced Radiometric Millimeter-Wave Scene Simulation (ARMSS) code is a rigorous, benchmarked, end-to-end passive millimeter-wave scene simulation code for interpreting millimeter-wave data, establishing scene signatures and evaluating sensor performance. In passive millimeter-wave imaging, resolution is limited due to wavelength and aperture size. Where high resolution is required, the utility of passive millimeter-wave imaging is confined to short ranges. Recent developments in interferometry have made possible high resolution applications on military platforms. Interferometry or synthetic aperture radiometry allows the creation of a high resolution image with a sparsely filled aperture. Borrowing from research work in radio astronomy, we have developed and tested at TRW scene reconstruction algorithms that allow the recovery of the scene from a relatively small number of spatial frequency components. In this paper, the TRW modeling capability is described and numerical results are presented.

  3. Enhanced detection method for corneal protein identification using shotgun proteomics

    Directory of Open Access Journals (Sweden)

    Schlager John J

    2009-06-01

    Full Text Available Abstract Background The cornea is a specialized transparent connective tissue responsible for the majority of light refraction and image focus for the retina. There are three main layers of the cornea: the epithelium that is exposed and acts as a protective barrier for the eye, the center stroma consisting of parallel collagen fibrils that refract light, and the endothelium that is responsible for hydration of the cornea from the aqueous humor. Normal cornea is an immunologically privileged tissue devoid of blood vessels, but injury can produce a loss of these conditions causing invasion of other processes that degrade the homeostatic properties resulting in a decrease in the amount of light refracted onto the retina. Determining a measure and drift of phenotypic cornea state from normal to an injured or diseased state requires knowledge of the existing protein signature within the tissue. In the study of corneal proteins, proteomics procedures have typically involved the pulverization of the entire cornea prior to analysis. Separation of the epithelium and endothelium from the core stroma and performing separate shotgun proteomics using liquid chromatography/mass spectrometry results in identification of many more proteins than previously employed methods using complete pulverized cornea. Results Rabbit corneas were purchased, the epithelium and endothelium regions were removed, proteins processed and separately analyzed using liquid chromatography/mass spectrometry. Proteins identified from separate layers were compared against results from complete corneal samples. Protein digests were separated using a six hour liquid chromatographic gradient and ion-trap mass spectrometry used for detection of eluted peptide fractions. The SEQUEST database search results were filtered to allow only proteins with match probabilities of equal or better than 10-3 and peptides with a probability of 10-2 or less with at least two unique peptides isolated within

  4. Precise quantitation of PAIgG: A new radiometric microtechnique

    International Nuclear Information System (INIS)

    Schwartz, K.A.; Gauger, J.A.; Davis, J.M.

    1990-01-01

    We report the development of a radiometric assay for platelet-bound IgG that is both sensitive and quantitative. The assay utilized 96-well millititer plates incorporating a 0.2 microns filter membrane in the bottom. A 125I-labeled monoclonal antihuman IgG, as a secondary antibody, detected the platelet-bound human IgG. Since 5 x 10(6) platelets were used for each assay, tests for platelet-bound IgG can be performed on persons with severe thrombocytopenia. For the detection of circulating antiplatelet alloantibodies, as little as 10 microliters of platelet-free plasma per assay is required. Antiplatelet IgG was quantitated by using anti-PIA1 antibody that was purified with affinity and elution and DEAE chromatography. This purified antiplatelet antibody was labeled with 125I and was used to determine the binding ratio of secondary antibody to primary antibody. Under our standard conditions, this ratio was found to be stable at approximately 0.35 over the sensitivity range of the assay. The assay can detect approximately 200 molecules of human IgG per platelet (0.1 ng of secondary antibody bound per 5 x 10(6) platelets). It has a linear range from 0 to 7,000 molecules per platelet. Quantitation of anti-PIA1 binding for platelets stored for up to 6 months under refrigeration showed no change in number of PIA1 binding sites. Clinical studies showed that 18 of 19 ITP patients had an increased number of IgG molecules per platelet as did patients with malignancy and drug-induced immune thrombocytopenia. Patients who had received multiple platelet transfusions had antiplatelet antibody in their plasma. Normal amounts of PAIgG were observed in platelets and plasma of patients with nonimmune thrombocytopenia

  5. Effect of surface density silver nanoplate films toward surface-enhanced Raman scattering enhancement for bisphenol A detection

    Science.gov (United States)

    Bakar, N. A.; Salleh, M. M.; Umar, A. A.; Shapter, J. G.

    2018-03-01

    This paper reports a study on surface-enhanced Raman scattering (SERS) phenomenon of triangular silver nanoplate (NP) films towards bisphenol A (BPA) detection. The NP films were prepared using self-assembly technique with four different immersion times; 1 hour, 2 hours, 5 hours, and 8 hours. The SERS measurement was studied by observing the changes in Raman spectra of BPA after BPA absorbed on the NP films. It was found that the Raman intensity of BPA peaks was enhanced by using the prepared SERS substrates. This is clearly indicated that these SERS silver substrates are suitable to sense industrial chemical and potentially used as SERS detector. However, the rate of SERS enhancement is depended on the distribution of NP on the substrate surface.

  6. Intelligent Agent-Based Intrusion Detection System Using Enhanced Multiclass SVM

    Science.gov (United States)

    Ganapathy, S.; Yogesh, P.; Kannan, A.

    2012-01-01

    Intrusion detection systems were used in the past along with various techniques to detect intrusions in networks effectively. However, most of these systems are able to detect the intruders only with high false alarm rate. In this paper, we propose a new intelligent agent-based intrusion detection model for mobile ad hoc networks using a combination of attribute selection, outlier detection, and enhanced multiclass SVM classification methods. For this purpose, an effective preprocessing technique is proposed that improves the detection accuracy and reduces the processing time. Moreover, two new algorithms, namely, an Intelligent Agent Weighted Distance Outlier Detection algorithm and an Intelligent Agent-based Enhanced Multiclass Support Vector Machine algorithm are proposed for detecting the intruders in a distributed database environment that uses intelligent agents for trust management and coordination in transaction processing. The experimental results of the proposed model show that this system detects anomalies with low false alarm rate and high-detection rate when tested with KDD Cup 99 data set. PMID:23056036

  7. Recent advances in airborne radiometric technology

    International Nuclear Information System (INIS)

    Jobst, J.E.

    1985-01-01

    Since its inception, the DOE Remote Sensing Laboratory has made dramatic innovations in airborne radiometric technology. In the past few years there have been at least four major changes in operational philosophy. (1) The helicopter is now the prime radiation survey vehicle. Surveys are conducted at low speed and low altitude, with lines spaced only a few hundred feet apart. Radiation anomalies and subtle changes in background can be readily identified. (2) Much greater emphasis is now placed on accurate, detailed analysis and interpretation of radiation data. Dramatic improvements in survey hardware and software provide much more data of considerably better quality. (3) Recent Laboratory research has been concentrated on error-free, positive identification of point radiation sources. In the past, the extent and magnitude of dispersed sources were the major concerns. (4) Integrated remote sensing has been strongly emphasized at the Laboratory in recent years. This involves the simultaneous use of radiation detectors, aerial cameras, and the multispectral scanner imagery. The synergistic effects of such data correlation are of significantly greater value in analyzing the terrestrial environment. Many of the changes in operational philosophy are directly traceable to new or dramatically improved hardware and software employed at the Laboratory. Six items have been instrumental in the above technological advances: (1) the UHF Transponder System and its predecessor, the Microwave Ranging System; (2) Model IC of the REDAR data acquisition system; (3) the development of the search algorithm; (4) continued improvements in the REDACA data analysis system; (5) deployment of polyscin sodium iodide radiation detectors; and (6) development of the Graphic Overview System

  8. Geometric Calibration and Radiometric Correction of LiDAR Data and Their Impact on the Quality of Derived Products

    Directory of Open Access Journals (Sweden)

    Wai-Yeung Yan

    2011-09-01

    Full Text Available LiDAR (Light Detection And Ranging systems are capable of providing 3D positional and spectral information (in the utilized spectrum range of the mapped surface. Due to systematic errors in the system parameters and measurements, LiDAR systems require geometric calibration and radiometric correction of the intensity data in order to maximize the benefit from the collected positional and spectral information. This paper presents a practical approach for the geometric calibration of LiDAR systems and radiometric correction of collected intensity data while investigating their impact on the quality of the derived products. The proposed approach includes the use of a quasi-rigorous geometric calibration and the radar equation for the radiometric correction of intensity data. The proposed quasi-rigorous calibration procedure requires time-tagged point cloud and trajectory position data, which are available to most of the data users. The paper presents a methodology for evaluating the impact of the geometric calibration on the relative and absolute accuracy of the LiDAR point cloud. Furthermore, the impact of the geometric calibration and radiometric correction on land cover classification accuracy is investigated. The feasibility of the proposed methods and their impact on the derived products are demonstrated through experimental results using real data.

  9. Enhanced change detection performance reveals improved strategy use in avid action video game players.

    Science.gov (United States)

    Clark, Kait; Fleck, Mathias S; Mitroff, Stephen R

    2011-01-01

    Recent research has shown that avid action video game players (VGPs) outperform non-video game players (NVGPs) on a variety of attentional and perceptual tasks. However, it remains unknown exactly why and how such differences arise; while some prior research has demonstrated that VGPs' improvements stem from enhanced basic perceptual processes, other work indicates that they can stem from enhanced attentional control. The current experiment used a change-detection task to explore whether top-down strategies can contribute to VGPs' improved abilities. Participants viewed alternating presentations of an image and a modified version of the image and were tasked with detecting and localizing the changed element. Consistent with prior claims of enhanced perceptual abilities, VGPs were able to detect the changes while requiring less exposure to the change than NVGPs. Further analyses revealed this improved change detection performance may result from altered strategy use; VGPs employed broader search patterns when scanning scenes for potential changes. These results complement prior demonstrations of VGPs' enhanced bottom-up perceptual benefits by providing new evidence of VGPs' potentially enhanced top-down strategic benefits. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    International Nuclear Information System (INIS)

    Gehl, H.B.; Bourne, M.; Grazioli, L.; Moeller, A.; Lodemann, K.P.

    2001-01-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  11. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gehl, H.B. [Inst. of Diagnostic Radiology, Medical Univ. of Luebeck (Germany); Bourne, M. [Dept. of Radiology, Univ. Hospital of Wales, Cardiff (United Kingdom); Grazioli, L. [Dept. of Radiology, Univ. of Brescia (Italy); Moeller, A. [MEDIDATA GmbH, Konstanz (Germany); Lodemann, K.P. [BRACCO-BYK GULDEN GmbH, Konstanz (Germany)

    2001-02-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  12. Surface-enhanced Raman scattering biosensor for DNA detection on nanoparticle island substrates

    DEFF Research Database (Denmark)

    Yuan, Scott Wu; Ho, Ho Pui; Lee, Rebecca K.Y.

    2009-01-01

    We present a study on the surface-enhanced Raman scattering (SERS) properties of Ag nanoparticle island substrates (NIS) and their applications for target oligonucleotide (OND) detection. It has been found that the surface nanostructure of NIS samples can be controlled with a good degree of repro......We present a study on the surface-enhanced Raman scattering (SERS) properties of Ag nanoparticle island substrates (NIS) and their applications for target oligonucleotide (OND) detection. It has been found that the surface nanostructure of NIS samples can be controlled with a good degree...

  13. Brightness-preserving fuzzy contrast enhancement scheme for the detection and classification of diabetic retinopathy disease.

    Science.gov (United States)

    Datta, Niladri Sekhar; Dutta, Himadri Sekhar; Majumder, Koushik

    2016-01-01

    The contrast enhancement of retinal image plays a vital role for the detection of microaneurysms (MAs), which are an early sign of diabetic retinopathy disease. A retinal image contrast enhancement method has been presented to improve the MA detection technique. The success rate on low-contrast noisy retinal image analysis shows the importance of the proposed method. Overall, 587 retinal input images are tested for performance analysis. The average sensitivity and specificity are obtained as 95.94% and 99.21%, respectively. The area under curve is found as 0.932 for the receiver operating characteristics analysis. The classifications of diabetic retinopathy disease are also performed here. The experimental results show that the overall MA detection method performs better than the current state-of-the-art MA detection algorithms.

  14. Subconscious detection of threat as reflected by an enhanced response bias.

    Science.gov (United States)

    Windmann, S; Krüger, T

    1998-12-01

    Neurobiological and cognitive models of unconscious information processing suggest that subconscious threat detection can lead to cognitive misinterpretations and false alarms, while conscious processing is assumed to be perceptually and conceptually accurate and unambiguous. Furthermore, clinical theories suggest that pathological anxiety results from a crude preattentive warning system predominating over more sophisticated and controlled modes of processing. We investigated the hypothesis that subconscious detection of threat in a cognitive task is reflected by enhanced "false signal" detection rather than by selectively enhanced discrimination of threat items in 30 patients with panic disorder and 30 healthy controls. We presented a tachistoscopic word-nonword discrimination task and a subsequent recognition task and analyzed the data by means of process-dissociation procedures. In line with our expectations, subjects of both groups showed more false signal detection to threat than to neutral stimuli as indicated by an enhanced response bias, whereas indices of discriminative sensitivity did not show this effect. In addition, patients with panic disorder showed a generally enhanced response bias in comparison to healthy controls. They also seemed to have processed the stimuli less elaborately and less differentially. Results are consistent with the assumption that subconscious threat detection can lead to misrepresentations of stimulus significance and that pathological anxiety is characterized by a hyperactive preattentive alarm system that is insufficiently controlled by higher cognitive processes. Copyright 1998 Academic Press.

  15. Detection of hepatocellular carcinoma: comparison of Gd-DTPA- and ferumoxides-enhanced MR imaging

    International Nuclear Information System (INIS)

    Simon, G.; Link, T.M.; Daldrup-Link, H.; Settles, M.; Woertler, K.; Doebereiner, F.; Schulte-Frohlinde, E.; Rummeny, E.J.

    2005-01-01

    The aim was to compare the diagnostic performance of dynamic Gd-DTPA- and ferumoxides-enhanced MRI for hepatocellular carcinoma (HCC). Twenty-five patients with chronic hepatitis or liver cirrhosis underwent both dynamic gadopentetate- and ferumoxides-enhanced MRI studies of the liver for HCC detection on the same day. MR data of both studies were retrospectively and independently analyzed. Two observers determined in consensus the grade of diffuse fibrotic liver changes (mild, moderate or severe) and the number of focal lesions. HCCs were confirmed by histology (n=22) and/or follow-up studies for at least six months (n=64). Differences in results obtained from both MR data sets were tested for significance with the McNemar's test (p 0.05) and Gd-DTPA-enhanced scans (94.2%). Gd-DTPA- and ferumoxides-enhanced MRI perform equally well for HCC detection. The majority of small hypervascular hepatic lesions, detected on dynamic Gd-DTPA-enhanced MRI but not on ferumoxides-enhanced MRI, represent no HCCs. (orig.)

  16. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. I

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Dillinger, P.; Harangozo, M.; Jombik, J.

    1980-01-01

    A method for the determination of salicylic, acetylsalicylic and benzoic acids in officinal pharmaceutical based on radiometric titration with 0.1 mol.l -1 NaOH was developed. The end-point was detected with the aid of radioactive glass kryptonate. After the end-point, the excess titrant attacks the glass surface layers and this results in releasing 85 Kr, and consequently, in decreasing the radioactivity of the kryptonate employed. The radioactive kryptonate used as an indicator was prepared by the bombardment of glass with accelerated 85 Kr ions. The developed method is simple, accurate and correct. (author)

  17. A radiometric mass flow probe for determining the screen overflow of potato harvesters

    International Nuclear Information System (INIS)

    Glaeser, M.

    1976-01-01

    A radiometric conveyor balance based on the principle of gamma attenuation is described. Being independent on the electric network, it is suitable for nonstationary operation. Cesium 137 is used as radiation source. Detection is performed through a special system of halogen and ordinary counters. First tests were made under field conditions in order to determine the passing mass (potatoes and soil) and to find out the sieving capacity of the potato harvesters. The maximum throughput is about 50 tons per hour. Potatoes and soil up to about 2 tons may be weighed by means of this balance with a relative error of +- 3.5 %. (author)

  18. Synthesis, radiometric determination of functional groups, complexation

    International Nuclear Information System (INIS)

    Pompe, S.; Bubner, M.; Schmeide, K.; Heise, K.H.; Bernhard, G.; Nitsche, H.

    2000-01-01

    The interaction behavior of humic acids with uranium(VI) and the influence of humic substances on the migration behavior of uranium was investigated. A main focus of this work was the synthesis of four different humic acid model substances and their characterization and comparison to the natural humic acid from Aldrich. A radiometric method for the determination of humic acid functional groups was applied in addition to conventional methods for the determination of the functionality of humic acids. The humic acid model substances show functional and structural properties comparable to natural humic acids. Modified humic acids with blocked phenolic OH were synthesized to determine the influence of phenolic OH groups on the complexation behavior of humic acids. A synthesis method for 14 C-labeled humic acids with high specific activity was developed. The complexation behavior of synthetic and natural humic acids with uranium(VI) was investigated by X-ray absorption spectroscopy, laser-induced fluorescence spectroscopy and FTIR spectroscopy. The synthetic model substances show an interaction behavior with uranium(VI) that is comparable to natural humic acids. This points to the fact that the synthetic humic acids simulate the functionality of their natural analogues very well. For the first time the influence of phenolic OH groups on the complexation behavior of humic acids was investigated by applying a modified humic acid with blocked phenolic OH groups. The formation of a uranyl hydroxy humate complex was identified by laserspectroscopic investigations of the complexation of Aldrich humic acid with uranium(VI) at pH 7. The migration behavior of uranium in a sandy aquifer system rich is humic substances was investigated in column experiments. A part of uranium migrates non-retarded through the sediment, bound to humic colloids. The uranium migration behavior is strongly influenced by the kinetically controlled interaction processes of uranium with the humic colloids

  19. Deep Space Network Radiometric Remote Sensing Program

    Science.gov (United States)

    Walter, Steven J.

    1994-01-01

    Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid, and precipitation, emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band because communication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of water vapor-induced propagation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity wave experiments, and radio science missions. During 1993, WVRs provided data for propagation model development, supported planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily

  20. Peptide separation by capillary electrophoresis with ultraviolet detection: Some simple approaches to enhance detection sensitivity and resolution

    International Nuclear Information System (INIS)

    Surugau, Noumie L.

    2011-01-01

    Capillary electrophoresis (CE) is one of the leading separation technologies for analysis of water-soluble analytes. CE has many advantages over the more established methods such as liquid chromatography and gel electrophoresis particularly in rapid analysis, require very little sample, use less or no toxic organic solvent, high peak efficiency and ease of automation. Despite the many attractive advantages of CE, CE users continue to seek improvements particularly on detection sensitivity, resolution and selectivity. This paper presented several simple approaches to improve detection sensitivity using simple sample pre-concentration called field-enhanced sample injection (FESI) and chromatographic-based ZipTip C 18 pre-concentrator. Also, some improvements in the resolution of complex peptides mixture when using two strategies namely, capillary coating and manipulation of the hydrophobicity of peptides using perfluorinated acids as background electrolyte (BGE), which have anionic conjugate base forms with hydrophobic character. As test compounds, standard peptide mixture and proteins digests were used for these studies. The results showed that FESI has significantly enhanced the detection signal of peptide standards and bovine serum albumin (BSA) tryptic digests. As for the use of ZipTip C 18 pre-concentrator, selective enhancement in detection signal was particularly notable on the late migrating peptides. Coating the capillary proved to have little changes on the CE of peptides when used in conjunction with acidic BGE. Electropherograms of BSA tryptic peptides in pentafluoropropionic acid (PFPA) and heptafluorobutyric acid (HFBA) showed interesting profile, with notable resolution improvement for peptides with close similarity in electrophoretic mobilities. (author)

  1. Radiometric measurement techniques in metallurgy and foundry technology

    International Nuclear Information System (INIS)

    1990-01-01

    The contributions contain informations concerning the present state and development of radiometric measurement techniques in metallurgy and foundry technology as well as their application to the solution of various problems. The development of isotope techniques is briefly described. Major applications of radiometric equipment in industrial measurement are presented together with the use of isotopes to monitor processes of industrial production. This is followed by a short description of numerous laboratory-scale applications. Another contribution deals with fundamental problems and methods of moisture measurement by neutrons. A complex moisture/density measurement device the practical applicability of which has been tested is described here. Possibilities for clay determination in used-up moulding materials are discussed in a further contribution. The clay content can be determined by real-time radiometric density measurement so that the necessary moisture or addition of fresh sand can be controlled. (orig.) With 20 figs., 9 tabs., 178 refs [de

  2. Urease testing of mycobacteria with BACTEC radiometric instrumentation

    International Nuclear Information System (INIS)

    Damato, J.J.; Collins, M.T.; McClatchy, J.K.

    1982-01-01

    A total of 140 mycobacterial isolates from patients treated at Fitzsimons Army Medical Center or the National Jewish Hospital and Research Center and from animal specimens submitted to the National Veterinary Services Laboratory were tested by using a urease procedure modified for use with a BACTEC model 301. Mycobacterial suspensions were prepared by using Middlebrook 7H10 Tween broth. Of the 98 mycobacteria isolates which were urease positive utilizing standard methodology, all were positive using the radiometric procedures. Similarly, all 42 urease-negative isolates were also negative employing the new methodology. Although maximum radiometric readings were observed at 48 h, all positive strains were readily identified 24 h after inoculation without sacrificing either test sensitivity or specificity. Thus, urease testing of mycobacteria, using the modified BACTEC radiometric methodology, was as sensitive, as specific, and more rapid than conventional methods

  3. Radiometric Cross-Calibration of GF-4 in Multispectral Bands

    Directory of Open Access Journals (Sweden)

    Aixia Yang

    2017-03-01

    Full Text Available The GaoFen-4 (GF-4, launched at the end of December 2015, is China’s first high-resolution geostationary optical satellite. A panchromatic and multispectral sensor (PMS is onboard the GF-4 satellite. Unfortunately, the GF-4 has no onboard calibration assembly, so on-orbit radiometric calibration is required. Like the charge-coupled device (CCD onboard HuanJing-1 (HJ or the wide field of view sensor (WFV onboard GaoFen-1 (GF-1, GF-4 also has a wide field of view, which provides challenges for cross-calibration with narrow field of view sensors, like the Landsat series. A new technique has been developed and used to calibrate HJ-1/CCD and GF-1/WFV, which is verified viable. The technique has three key steps: (1 calculate the surface using the bi-directional reflectance distribution function (BRDF characterization of a site, taking advantage of its uniform surface material and natural topographic variation using Landsat Enhanced Thematic Mapper Plus (ETM+/Operational Land Imager (OLI imagery and digital elevation model (DEM products; (2 calculate the radiance at the top-of-the atmosphere (TOA with the simulated surface reflectance using the atmosphere radiant transfer model; and (3 fit the calibration coefficients with the TOA radiance and corresponding Digital Number (DN values of the image. This study attempts to demonstrate the technique is also feasible to calibrate GF-4 multispectral bands. After fitting the calibration coefficients using the technique, extensive validation is conducted by cross-validation using the image pairs of GF-4/PMS and Landsat-8/OLI with similar transit times and close view zenith. The validation result indicates a higher accuracy and frequency than that given by the China Centre for Resources Satellite Data and Application (CRESDA using vicarious calibration. The study shows that the new technique is also quite feasible for GF-4 multispectral bands as a routine long-term procedure.

  4. The use of Nanotrap particles in the enhanced detection of Rift Valley fever virus nucleoprotein.

    Directory of Open Access Journals (Sweden)

    Nazly Shafagati

    Full Text Available Rift Valley fever virus (RVFV is a highly pathogenic arthropod-borne virus that has a detrimental effect on both livestock and human populations. While there are several diagnostic methodologies available for RVFV detection, many are not sensitive enough to diagnose early infections. Furthermore, detection may be hindered by high abundant proteins such as albumin. Previous findings have shown that Nanotrap particles can be used to significantly enhance detection of various small analytes of low abundance. We have expanded upon this repertoire to show that this simple and efficient sample preparation technology can drastically improve the detection of the RVFV nucleoprotein (NP, the most abundant and widely used viral protein for RVFV diagnostics.After screening multiple Nanotrap particle architectures, we found that one particle, NT45, was optimal for RVFV NP capture, as demonstrated by western blotting. NT45 significantly enhanced detection of the NP at levels undetectable without the technology. Importantly, we demonstrated that Nanotrap particles are capable of concentrating NP in a number of matrices, including infected cell lysates, viral supernatants, and animal sera. Specifically, NT45 enhanced detection of NP at various viral titers, multiplicity of infections, and time points. Our most dramatic results were observed in spiked serum samples, where high abundance serum proteins hindered detection of NP without Nanotrap particles. Nanotrap particles allowed for sample cleanup and subsequent detection of RVFV NP. Finally, we demonstrated that incubation of our samples with Nanotrap particles protects the NP from degradation over extended periods of time (up to 120 hours and at elevated temperatures (at 37ºC.This study demonstrates that Nanotrap particles are capable of drastically lowering the limit of detection for RVFV NP by capturing, concentrating, and preserving RVFV NP in clinically relevant matrices. These studies can be extended to

  5. Surface-enhanced Raman scattering (SERS) for detection of phenylketonuria for newborn screening

    Science.gov (United States)

    Javanmard, M.; Davis, R. W.

    2014-02-01

    Diagnosis of Phenylketonuria (PKU) in newborns is important because it can potentially help prevent mental retardation since it is treatable by dietary means. PKU results in phenylketonurics having phenylalanine levels as high as 2 mM whereas the normal upper limit in healthy newborns is 120 uM. To this end, we are developing a microfluidic platform integrated with a SERS substrate for detection of high levels of phenylalanine. We have successfully demonstrated SERS detection of phenylalanine using various SERS substrates fabricated using nanosphere lithography, which exhibit high levels of field enhancement. We show detection of SERS at clinically relevant levels.

  6. Detection of Molecular Oxygen at Low Concentrations Using Quartz Enhanced Photoacoustic Spectroscopy

    Directory of Open Access Journals (Sweden)

    Andreas Pohlkötter

    2010-09-01

    Full Text Available Molecular oxygen is detected at low concentrations using photoacoustic spectroscopy despite its unfavorable photoacoustic properties. The system consists of a seed laser diode, a tapered amplifier and a quartz tuning fork based spectrophone, thus employing quartz enhanced photoacoustic spectroscopy (QEPAS. With this system a detection limit of 13 ppm is reached with a compact and long term stable setup. Further improvement of the detection limit is possible by adding suitable gases to the sample gas that promote the radiationless de-excitation of the oxygen molecules.

  7. Enhanced terahertz detection using multiple GaAs HEMTs connected in series

    KAUST Repository

    Elkhatib, Tamer A.; Veksler, Dmitry B.; Salama, Khaled N.; Zhang, Xi-C.; Shur, Michael S.

    2012-01-01

    We report here, for the first time, on enhanced nonresonant detection of terahertz radiation using multiple InGaAs/GaAs high-electron-mobility transistors (HEMTs) connected in series and biased by a direct drain current. A 1.63 THz (184 mum) response is proportional to the number of detecting transistors operating in saturation region at the same gate-source bias voltage. The experimental data are in agreement with the detection mechanism based on the rectification of overdamped plasma waves excited by radiation in channels of devices.

  8. Enhanced terahertz detection using multiple GaAs HEMTs connected in series

    KAUST Repository

    Elkhatib, Tamer A.

    2012-07-28

    We report here, for the first time, on enhanced nonresonant detection of terahertz radiation using multiple InGaAs/GaAs high-electron-mobility transistors (HEMTs) connected in series and biased by a direct drain current. A 1.63 THz (184 mum) response is proportional to the number of detecting transistors operating in saturation region at the same gate-source bias voltage. The experimental data are in agreement with the detection mechanism based on the rectification of overdamped plasma waves excited by radiation in channels of devices.

  9. Making the invisible visible: verbal but not visual cues enhance visual detection.

    Science.gov (United States)

    Lupyan, Gary; Spivey, Michael J

    2010-07-07

    Can hearing a word change what one sees? Although visual sensitivity is known to be enhanced by attending to the location of the target, perceptual enhancements of following cues to the identity of an object have been difficult to find. Here, we show that perceptual sensitivity is enhanced by verbal, but not visual cues. Participants completed an object detection task in which they made an object-presence or -absence decision to briefly-presented letters. Hearing the letter name prior to the detection task increased perceptual sensitivity (d'). A visual cue in the form of a preview of the to-be-detected letter did not. Follow-up experiments found that the auditory cuing effect was specific to validly cued stimuli. The magnitude of the cuing effect positively correlated with an individual measure of vividness of mental imagery; introducing uncertainty into the position of the stimulus did not reduce the magnitude of the cuing effect, but eliminated the correlation with mental imagery. Hearing a word made otherwise invisible objects visible. Interestingly, seeing a preview of the target stimulus did not similarly enhance detection of the target. These results are compatible with an account in which auditory verbal labels modulate lower-level visual processing. The findings show that a verbal cue in the form of hearing a word can influence even the most elementary visual processing and inform our understanding of how language affects perception.

  10. Making the invisible visible: verbal but not visual cues enhance visual detection.

    Directory of Open Access Journals (Sweden)

    Gary Lupyan

    Full Text Available BACKGROUND: Can hearing a word change what one sees? Although visual sensitivity is known to be enhanced by attending to the location of the target, perceptual enhancements of following cues to the identity of an object have been difficult to find. Here, we show that perceptual sensitivity is enhanced by verbal, but not visual cues. METHODOLOGY/PRINCIPAL FINDINGS: Participants completed an object detection task in which they made an object-presence or -absence decision to briefly-presented letters. Hearing the letter name prior to the detection task increased perceptual sensitivity (d'. A visual cue in the form of a preview of the to-be-detected letter did not. Follow-up experiments found that the auditory cuing effect was specific to validly cued stimuli. The magnitude of the cuing effect positively correlated with an individual measure of vividness of mental imagery; introducing uncertainty into the position of the stimulus did not reduce the magnitude of the cuing effect, but eliminated the correlation with mental imagery. CONCLUSIONS/SIGNIFICANCE: Hearing a word made otherwise invisible objects visible. Interestingly, seeing a preview of the target stimulus did not similarly enhance detection of the target. These results are compatible with an account in which auditory verbal labels modulate lower-level visual processing. The findings show that a verbal cue in the form of hearing a word can influence even the most elementary visual processing and inform our understanding of how language affects perception.

  11. Resonantly enhanced nonlinear optics in semiconductor quantum wells: An application to sensitive infrared detection

    International Nuclear Information System (INIS)

    Yelin, S.F.; Hemmer, P.R.

    2002-01-01

    A novel class of coherent nonlinear optical phenomena, involving induced transparency in semiconductor quantum wells, is considered in the context of a particular application to sensitive long-wavelength infrared detection. It is shown that the strongest decoherence mechanisms can be suppressed or mitigated, resulting in substantial enhancement of nonlinear optical effects in semiconductor quantum wells

  12. Liver metastases: Sulphur hexafluoride-enhanced ultrasonography for lesion detection: a systematic review

    NARCIS (Netherlands)

    Cabassa, Paolo; Bipat, Shandra; Longaretti, Laura; Morone, Mario; Maroldi, Roberto

    2010-01-01

    This is a systematic review to evaluate the accuracy of contrast-enhanced ultrasonography (CEUS) performed with "SonoVue" (sulphur hexafluoride) in the detection of hepatic metastases. The MEDLINE, EMBASE and COCHRANE Databases were searched, regardless of language, for relevant articles published

  13. Radiometric microbiologic assay for the biologically active forms of niacin

    International Nuclear Information System (INIS)

    Kertcher, J.A.; Guilarte, T.R.; Chen, M.F.; Rider, A.A.; McIntyre, P.A.

    1979-01-01

    A radiometric microbiologic assay has been developed for the determination of niacin in biologic fluids. Lactobacillus plantarum produced 14 CO 2 from L-[U- 14 C] malic acid in quantities proportional to the amount of niacin present. The assay is specific for the biologically active forms of niacin in humans. Thirty normal hemolysates were analyzed and the values ranged from 13.0 to 17.8 μg niacin/ml RBC (mean = 15.27 +- 1.33 s.d.). Good recovery and reproducibility studies were obtained with this assay. On thirty blood samples, correlation was excellent between the radiometric and the conventional turbidimetric assays

  14. Testing of X-ray radiometric enrichnment of polymetallic ores

    International Nuclear Information System (INIS)

    Eliseev, N.I.; Panova, N.I.; Kirbitova, N.V.; Shramm, E.O.; Efremov, Yu.G.

    1987-01-01

    Testing of X-ray radiometric method of sorting of polymetallic ores using the developed X-ray radiometric device was conducted. It was shown that introduction of preliminary concentration at the factory made the method of fragment separation to be the perspective one, enabling to elevate the factory production with respect to commercial ore and reduce the cost of ore processing. In the case of preliminary concentration, conducted at the mine, it is advisable to perform ore sorting in the flow formed to monolayer

  15. Automated Detection of Healthy and Diseased Aortae from Images Obtained by Contrast-Enhanced CT Scan

    Directory of Open Access Journals (Sweden)

    Michael Gayhart

    2013-01-01

    Full Text Available Purpose. We developed the next stage of our computer assisted diagnosis (CAD system to aid radiologists in evaluating CT images for aortic disease by removing innocuous images and highlighting signs of aortic disease. Materials and Methods. Segmented data of patient’s contrast-enhanced CT scan was analyzed for aortic dissection and penetrating aortic ulcer (PAU. Aortic dissection was detected by checking for an abnormal shape of the aorta using edge oriented methods. PAU was recognized through abnormally high intensities with interest point operators. Results. The aortic dissection detection process had a sensitivity of 0.8218 and a specificity of 0.9907. The PAU detection process scored a sensitivity of 0.7587 and a specificity of 0.9700. Conclusion. The aortic dissection detection process and the PAU detection process were successful in removing innocuous images, but additional methods are necessary for improving recognition of images with aortic disease.

  16. Contrast-enhanced ultrasound features of hepatocellular carcinoma not detected during the screening procedure.

    Science.gov (United States)

    Dong, Yi; Wang, Wen-Ping; Mao, Feng; Dietrich, Christoph

    2017-08-01

    Aim  The aim of this retrospective study is to report on the characteristics of contrast-enhanced ultrasound (CEUS) of primarily not detected hepatocellular carcinoma (HCC) during the screening procedure of patients at risk. Methods  Sixty-four patients with a finally solitary and histologically proven HCC not detected HCC during the screening procedure were retrospectively analyzed. Most of HCC lesions (90.6 %, 58/64) measured < 20 mm in diameter. All HCC lesions were not detected during the initial screening procedure but suspected using contrast-enhanced magnetic resonance imaging. The final gold standard was biopsy or surgery with histological examination. Results  On CEUS, 62/64 (96.8 %) of HCC were characterized as an obviously hyperenhanced lesion in arterial phase, and 41/64 (64.1 %) of HCC were characterized as hypoenhancing lesions in the portal venous and late phases. During the arterial phase of CEUS, 96.8 % of HCC displayed homogeneous hyperenhancement. Knowing the CEUS and magnetic resonance imaging findings, 45/64 (70.3 %) could have been detected using B-mode ultrasound (BMUS). Conclusion  BMUS as a screening procedure is generally accepted. Contrast-enhanced imaging modalities have improved detection and characterization of HCC. Homogeneous hyperenhancement during the arterial phase and mild washout are indicative for HCC in liver cirrhosis. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Antibody-nanoparticle conjugates to enhance the sensitivity of ELISA-based detection methods.

    Directory of Open Access Journals (Sweden)

    Margaret M Billingsley

    Full Text Available Accurate antigen detection is imperative for clinicians to diagnose disease, assess treatment success, and predict patient prognosis. The most common technique used for the detection of disease-associated biomarkers is the enzyme linked immunosorbent assay (ELISA. In an ELISA, primary antibodies are incubated with biological samples containing the biomarker of interest. Then, detectible secondary antibodies conjugated with horseradish peroxidase (HRP bind the primary antibodies. Upon addition of a color-changing substrate, the samples provide a colorimetric signal that directly correlates to the targeted biomarker concentration. While ELISAs are effective for analyzing samples with high biomarker content, they lack the sensitivity required to analyze samples with low antigen levels. We hypothesized that the sensitivity of ELISAs could be enhanced by replacing freely delivered primary antibodies with antibody-nanoparticle conjugates that provide excess binding sites for detectible secondary antibodies, ultimately leading to increased signal. Here, we investigated the use of nanoshells (NS decorated with antibodies specific to epidermal growth factor receptor (EGFR as a model system (EGFR-NS. We incubated one healthy and two breast cancer cell lines, each expressing different levels of EGFR, with EGFR-NS, untargeted NS, or unconjugated EGFR antibodies, as well as detectable secondary antibodies. We found that EGFR-NS consistently increased signal intensity relative to unconjugated EGFR antibodies, with a substantial 13-fold enhancement from cells expressing high levels of EGFR. Additionally, 40x more unconjugated antibodies were required to detect EGFR compared to those conjugated to NS. Our results demonstrate that antibody-nanoparticle conjugates lower the detection limit of traditional ELISAs and support further investigation of this strategy with other antibodies and nanoparticles. Owing to their enhanced sensitivity, we anticipate that

  18. The use of contrast-enhanced post Mortem CT in the detection of cardiovascular deaths.

    Directory of Open Access Journals (Sweden)

    Jonas Christoph Apitzsch

    Full Text Available OBJECTIVES: To evaluate the diagnostic value of contrast enhanced post mortem computed tomography (PMCT in comparison to non-enhanced post mortem CT in the detection of cardiovascular causes of death (COD. BACKGROUND: As autopsy rates decline, new methods to determine CODs are necessary. So contrast enhanced PMCT shall be evaluated in comparison to established non-enhanced PMCT in order to further improve the method. METHODS: In a prospective study, 20 corpses were examined using a 64-row multisclice CT (MSCT before and after intraarterial perfusion with a newly developed, barium-bearing contrast agent and ventilation of the lungs. The cause of death was determined in enhanced and unenhanced scans and a level of confidence (LOC was given by three experienced radiologists on a scale between 0 and 4. Results were compared to autopsy results as gold standard. Autopsy was performed blinded to PMCT-findings. RESULTS: The method allowed visualization of different types of cause of death. There was a significant improvement in LOC in enhanced scans compared to unenhanced scans as well as an improvement in the detection of COD. The cause of death could be determined in 19 out of 20 patients. CONCLUSIONS: PMCT is feasible and appears to be robust for diagnosing cardiovascular causes of death. When compared with unenhanced post-mortem CT intraarterial perfusion and pulmonary ventilation significantly improve visualization and diagnostic accuracy. These promising results warrant further studies.

  19. Cross-modal enhancement of speech detection in young and older adults: does signal content matter?

    Science.gov (United States)

    Tye-Murray, Nancy; Spehar, Brent; Myerson, Joel; Sommers, Mitchell S; Hale, Sandra

    2011-01-01

    The purpose of the present study was to examine the effects of age and visual content on cross-modal enhancement of auditory speech detection. Visual content consisted of three clearly distinct types of visual information: an unaltered video clip of a talker's face, a low-contrast version of the same clip, and a mouth-like Lissajous figure. It was hypothesized that both young and older adults would exhibit reduced enhancement as visual content diverged from the original clip of the talker's face, but that the decrease would be greater for older participants. Nineteen young adults and 19 older adults were asked to detect a single spoken syllable (/ba/) in speech-shaped noise, and the level of the signal was adaptively varied to establish the signal-to-noise ratio (SNR) at threshold. There was an auditory-only baseline condition and three audiovisual conditions in which the syllable was accompanied by one of the three visual signals (the unaltered clip of the talker's face, the low-contrast version of that clip, or the Lissajous figure). For each audiovisual condition, the SNR at threshold was compared with the SNR at threshold for the auditory-only condition to measure the amount of cross-modal enhancement. Young adults exhibited significant cross-modal enhancement with all three types of visual stimuli, with the greatest amount of enhancement observed for the unaltered clip of the talker's face. Older adults, in contrast, exhibited significant cross-modal enhancement only with the unaltered face. Results of this study suggest that visual signal content affects cross-modal enhancement of speech detection in both young and older adults. They also support a hypothesized age-related deficit in processing low-contrast visual speech stimuli, even in older adults with normal contrast sensitivity.

  20. Nano-particle enhanced impedimetric biosensor for detection of foodborne pathogens

    International Nuclear Information System (INIS)

    Kim, G; Om, A S; Mun, J H

    2007-01-01

    Recent outbreaks of foodborne illness have been increased the need for rapid and sensitive methods for detection of these pathogens. Conventional methods for pathogens detection and identification involve prolonged multiple enrichment steps. Even though some immunological rapid assays are available, these assays still need enrichment steps result in delayed detection. Biosensors have shown great potential for rapid detection of foodborne pathogens. They are capable of direct monitoring the antigen-antibody reactions in real time. Among the biosensors, impedimetric biosensors have been widely adapted as an analysis tool for the study of various biological binding reactions because of their high sensitivity and reagentless operation. In this study a nanoparticle-enhanced impedimetric biosensor for Salmonella enteritidis detection was developed which detected impedance changes caused by the attachment of the cells to the anti-Salmonella antibodies immobilized on interdigitated gold electrodes. Successive immobilization of neutravidin followed by anti-Salmonella antibodies was performed to the sensing area to create a biological detection surface. To enhance the impedance responses generated by antigen-antibody reactions, anti-Salmonella antibody conjugated nanoparticles were introduced on the sensing area. Using a portable impedance analyzer, the impedance across the interdigital electrodes was measured after the series of antigen-antibody bindings. Bacteria cells present in solution attached to capture antibodies and became tethered to the sensor surface. Attached bacteria cells changed the dielectric constant of the media between the electrodes thereby causing a change in measured impedance. Optimum input frequency was determined by analyzing frequency characteristics of the biosensor over ranges of applied frequencies from 10 Hz to 400 Hz. At 100 Hz of input frequency, the biosensor was most sensitive to the changes of the bacteria concentration and this frequency

  1. Metal Nanoparticles/Porous Silicon Microcavity Enhanced Surface Plasmon Resonance Fluorescence for the Detection of DNA

    Directory of Open Access Journals (Sweden)

    Jiajia Wang

    2018-02-01

    Full Text Available A porous silicon microcavity (PSiMC with resonant peak wavelength of 635 nm was fabricated by electrochemical etching. Metal nanoparticles (NPs/PSiMC enhanced fluorescence substrates were prepared by the electrostatic adherence of Au NPs that were distributed in PSiMC. The Au NPs/PSiMC device was used to characterize the target DNA immobilization and hybridization with its complementary DNA sequences marked with Rhodamine red (RRA. Fluorescence enhancement was observed on the Au NPs/PSiMC device substrate; and the minimum detection concentration of DNA ran up to 10 pM. The surface plasmon resonance (SPR of the MC substrate; which is so well-positioned to improve fluorescence enhancement rather the fluorescence enhancement of the high reflection band of the Bragg reflector; would welcome such a highly sensitive in biosensor.

  2. Metal Nanoparticles/Porous Silicon Microcavity Enhanced Surface Plasmon Resonance Fluorescence for the Detection of DNA.

    Science.gov (United States)

    Wang, Jiajia; Jia, Zhenhong

    2018-02-23

    A porous silicon microcavity (PSiMC) with resonant peak wavelength of 635 nm was fabricated by electrochemical etching. Metal nanoparticles (NPs)/PSiMC enhanced fluorescence substrates were prepared by the electrostatic adherence of Au NPs that were distributed in PSiMC. The Au NPs/PSiMC device was used to characterize the target DNA immobilization and hybridization with its complementary DNA sequences marked with Rhodamine red (RRA). Fluorescence enhancement was observed on the Au NPs/PSiMC device substrate; and the minimum detection concentration of DNA ran up to 10 pM. The surface plasmon resonance (SPR) of the MC substrate; which is so well-positioned to improve fluorescence enhancement rather the fluorescence enhancement of the high reflection band of the Bragg reflector; would welcome such a highly sensitive in biosensor.

  3. A PDMS-based cylindrical hybrid lens for enhanced fluorescence detection in microfluidic systems.

    Science.gov (United States)

    Lin, Bor-Shyh; Yang, Yu-Ching; Ho, Chong-Yi; Yang, Han-Yu; Wang, Hsiang-Yu

    2014-02-13

    Microfluidic systems based on fluorescence detection have been developed and applied for many biological and chemical applications. Because of the tiny amount of sample in the system; the induced fluorescence can be weak. Therefore, most microfluidic systems deploy multiple optical components or sophisticated equipment to enhance the efficiency of fluorescence detection. However, these strategies encounter common issues of complex manufacturing processes and high costs. In this study; a miniature, cylindrical and hybrid lens made of polydimethylsiloxane (PDMS) to improve the fluorescence detection in microfluidic systems is proposed. The hybrid lens integrates a laser focusing lens and a fluorescence collecting lens to achieve dual functions and simplify optical setup. Moreover, PDMS has advantages of low-cost and straightforward fabrication compared with conventional optical components. The performance of the proposed lens is first examined with two fluorescent dyes and the results show that the lens provides satisfactory enhancement for fluorescence detection of Rhodamine 6G and Nile Red. The overall increments in collected fluorescence signal and detection sensitivity are more than 220% of those without lens, and the detection limits of Rhodamine 6G and Nile red are lowered to 0.01 μg/mL and 0.05 μg/mL, respectively. The hybrid lens is further applied to the detection of Nile red-labeled Chlorella vulgaris cells and it increases both signal intensity and detection sensitivity by more than 520%. The proposed hybrid lens also dramatically reduces the variation in detected signal caused by the deviation in incident angle of excitation light.

  4. Determination of molybdenite leaching degree by x-ray radiometric analysis

    International Nuclear Information System (INIS)

    Bibinov, S.A.; Gladyshev, V.P.; Yarmolik, A.S.; Kim, A.Ch.; Sokur, N.P.

    1984-01-01

    A express chemical X-ray radiometric method for determination of leaching degree and analysis of molybdenite products is developed. The method comprises chemical preparation and the following X-ray radiometric determination of molyb bdenum. Total duration of the analysis is 1-1.5 h. The best reproductivity is btained at X-ray radiometric analysis as compared with the chemical one

  5. Quantitative electrical detection of immobilized protein using gold nanoparticles and gold enhancement on a biochip

    International Nuclear Information System (INIS)

    Lei, Kin Fong

    2011-01-01

    Electrical detection of the concentration of protein immobilized on a biochip is demonstrated. The concentration of the direct immobilized protein can be determined by the resistance values measured by an ohm-meter directly. Indium tin oxide interdigitated electrodes were utilized as the detection sites on the biochip. Protein, i.e. antibody, of certain concentration was first immobilized on the detection site. Gold nanoparticles were then applied to indicate the immobilized protein. Since the gold nanoparticles were tiny, a detectable electrical signal could not be generated. Hence, a gold enhancement process was performed for signal amplification. Gold nanoparticles were enlarged physically, such that a conductive metal layer was formed on the detection site. The presence and concentration of protein can be determined by the resistance value across the electrode measured by an ohm-meter. An immobilized protein concentration ranging from 50 to 1000 ng ml −1 can be detected quantitatively by the resistance values from 4300 to 1700 Ω. The proposed technique is potentially extended for the detection of immunoassay on the biochip. Since the protocol of the electrical detection does not involve sophisticated equipment, it can therefore be used for the development of a portable immunoassay device

  6. Automatic detection of arterial input function in dynamic contrast enhanced MRI based on affinity propagation clustering.

    Science.gov (United States)

    Shi, Lin; Wang, Defeng; Liu, Wen; Fang, Kui; Wang, Yi-Xiang J; Huang, Wenhua; King, Ann D; Heng, Pheng Ann; Ahuja, Anil T

    2014-05-01

    To automatically and robustly detect the arterial input function (AIF) with high detection accuracy and low computational cost in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). In this study, we developed an automatic AIF detection method using an accelerated version (Fast-AP) of affinity propagation (AP) clustering. The validity of this Fast-AP-based method was proved on two DCE-MRI datasets, i.e., rat kidney and human head and neck. The detailed AIF detection performance of this proposed method was assessed in comparison with other clustering-based methods, namely original AP and K-means, as well as the manual AIF detection method. Both the automatic AP- and Fast-AP-based methods achieved satisfactory AIF detection accuracy, but the computational cost of Fast-AP could be reduced by 64.37-92.10% on rat dataset and 73.18-90.18% on human dataset compared with the cost of AP. The K-means yielded the lowest computational cost, but resulted in the lowest AIF detection accuracy. The experimental results demonstrated that both the AP- and Fast-AP-based methods were insensitive to the initialization of cluster centers, and had superior robustness compared with K-means method. The Fast-AP-based method enables automatic AIF detection with high accuracy and efficiency. Copyright © 2013 Wiley Periodicals, Inc.

  7. Spatial and radiometric characterization of multi-spectrum satellite images through multi-fractal analysis

    Science.gov (United States)

    Alonso, Carmelo; Tarquis, Ana M.; Zúñiga, Ignacio; Benito, Rosa M.

    2017-03-01

    Several studies have shown that vegetation indexes can be used to estimate root zone soil moisture. Earth surface images, obtained by high-resolution satellites, presently give a lot of information on these indexes, based on the data of several wavelengths. Because of the potential capacity for systematic observations at various scales, remote sensing technology extends the possible data archives from the present time to several decades back. Because of this advantage, enormous efforts have been made by researchers and application specialists to delineate vegetation indexes from local scale to global scale by applying remote sensing imagery. In this work, four band images have been considered, which are involved in these vegetation indexes, and were taken by satellites Ikonos-2 and Landsat-7 of the same geographic location, to study the effect of both spatial (pixel size) and radiometric (number of bits coding the image) resolution on these wavelength bands as well as two vegetation indexes: the Normalized Difference Vegetation Index (NDVI) and the Enhanced Vegetation Index (EVI). In order to do so, a multi-fractal analysis of these multi-spectral images was applied in each of these bands and the two indexes derived. The results showed that spatial resolution has a similar scaling effect in the four bands, but radiometric resolution has a larger influence in blue and green bands than in red and near-infrared bands. The NDVI showed a higher sensitivity to the radiometric resolution than EVI. Both were equally affected by the spatial resolution. From both factors, the spatial resolution has a major impact in the multi-fractal spectrum for all the bands and the vegetation indexes. This information should be taken in to account when vegetation indexes based on different satellite sensors are obtained.

  8. Fast and sensitive detection of ochratoxin A in red wine by nanoparticle-enhanced SPR.

    Science.gov (United States)

    Karczmarczyk, Aleksandra; Reiner-Rozman, Ciril; Hageneder, Simone; Dubiak-Szepietowska, Monika; Dostálek, Jakub; Feller, Karl-Heinz

    2016-09-21

    Herein, we present a fast and sensitive biosensor for detection of Ochratoxin A (OTA) in a red wine that utilizes gold nanoparticle-enhanced surface plasmon resonance (SPR). By combining an indirect competitive inhibition immunoassay and signal enhancement by secondary antibodies conjugated with gold nanoparticles (AuNPs), highly sensitive detection of low molecular weight compounds (such as OTA) was achieved. The reported biosensor allowed for OTA detection at concentrations as low as 0.75 ng mL(-1) and its limit of detection was improved by more than one order of magnitude to 0.068 ng mL(-1) by applying AuNPs as a signal enhancer. The study investigates the interplay of size of AuNPs and affinity of recognition elements affecting the efficiency of the signal amplification strategy based on AuNP. Furthermore, we observed that the presence of polyphenolic compounds in wine samples strongly interferes with the affinity binding on the surface. To overcome this limitation, a simple pre-treatment of the wine sample with the binding agent poly(vinylpyrrolidone) (PVP) was successfully applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Enhancement of the conductivity detection signal in capillary electrophoresis systems using neutral cyclodextrins as sweeping agents.

    Science.gov (United States)

    Boublík, Milan; Riesová, Martina; Dubský, Pavel; Gaš, Bohuslav

    2018-06-01

    Conductivity detection is a universal detection technique often encountered in electrophoretic separation systems, especially in modern chip-electrophoresis based devices. On the other hand, it is sparsely combined with another contemporary trend of enhancing limits of detection by means of various preconcentration strategies. This can be attributed to the fact that a preconcentration experimental setup usually brings about disturbances in a conductivity baseline. Sweeping with a neutral sweeping agent seems a good candidate for overcoming this problem. A neutral sweeping agent does not hinder the conductivity detection while a charged analyte may preconcentrate on its boundary due to a decrease in its effective mobility. This study investigates such sweeping systems theoretically, by means of computer simulations, and experimentally. A formula is provided for the reliable estimation of the preconcentration factor. Additionally, it is demonstrated that the conductivity signal can significantly benefit from slowing down the analyte and thus the overall signal enhancement can easily overweight amplification caused solely by the sweeping process. The overall enhancement factor can be deduced a priori from the linearized theory of electrophoresis implemented in the PeakMaster freeware. Sweeping by neutral cyclodextrin is demonstrated on an amplification of a conductivity signal of flurbiprofen in a real drug sample. Finally, a possible formation of unexpected system peaks in systems with a neutral sweeping agent is revealed by the computer simulation and confirmed experimentally. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Sensitive Detection of Biomolecules by Surface Enhanced Raman Scattering using Plant Leaves as Natural Substrates

    Directory of Open Access Journals (Sweden)

    Sharma Vipul

    2017-01-01

    Full Text Available Detection of biomolecules is highly important for biomedical and other biological applications. Although several methods exist for the detection of biomolecules, surface enhanced Raman scattering (SERS has a unique role in greatly enhancing the sensitivity. In this work, we have demonstrated the use of natural plant leaves as facile, low cost and eco-friendly SERS substrates for the sensitive detection of biomolecules. Specifically, we have investigated the influence of surface topography of five different plant leaf based substrates, deposited with Au, on the SERS performance by using L-cysteine as a model biomolecule. In addition, we have also compared the effect of sputter deposition of Au thin film with dropcast deposition of Au nanoparticles on the leaf substrates. Our results indicate that L-cysteine could be detected with high sensitivity using these plant leaf based substrates and the leaf possessing hierarchical micro/nanostructures on its surface shows higher SERS enhancement compared to a leaf having a nearplanar surface. Furthermore, leaves with drop-casted Au nanoparticle clusters performed better than the leaves sputter deposited with a thin Au film.

  11. Radiometric densimeter for measuring and automatic control of liquid density

    International Nuclear Information System (INIS)

    Wajs, J.

    1982-01-01

    A performance rule of the radiometric densimeter produced by ''POLON ''Works is presented. A simplified analysis of the correction of density indication changes due to liquid temperature variations is described. A method of replacing the measuring pipe carrying the liquid being measured by suitable standards is given. The method is for automatic systems control. (A.S.)

  12. Pukaki 1-01 : initial luminescence dating and radiometric measurements

    International Nuclear Information System (INIS)

    Rieser, U.

    2001-01-01

    Core from Pukaki 1-01 was sampled for luminescence dating and radiometric measurements on 14 March 2001 in the dark room laboratory at Victoria University. Seven samples were taken to get an overview of the crater history, and laboratory work was completed in August 2001. (author). 2 figs., 3 tabs

  13. A review of recent developments in radiometric calibration facilities

    International Nuclear Information System (INIS)

    Corner, B.

    1984-01-01

    Two new developments concerning radiometric calibration facilities are described in this presentation. The first is the result of the international programme for the monitoring and cross-reference of existing calibration facilities, sponsored by the International Atomic Energy Agency. The second development that is discussed concerns the accuracy of the stripping ratios derived at Pelindaba and has important implications for in situ assaying

  14. Assessment of Aero-radiometric Data of Southern Anambra Basin ...

    African Journals Online (AJOL)

    High-resolution aero-radiometric data from three radio-elements (Uranium, Potassium and Thorium) were used and processed independently to investigate the Southern Anambra basin for the prospect of producing radiogenic heat. The rock types in the study area were outlined while processing the elements in each rock ...

  15. PLEIADES-HR INNOVATIVE TECHNIQUES FOR RADIOMETRIC IMAGE QUALITY COMMISSIONING

    Directory of Open Access Journals (Sweden)

    G. Blanchet

    2012-07-01

    Full Text Available The first Pleiades-HR satellite, part of a constellation of two, has been launched on December 17, 2011. This satellite produces high resolution optical images. In order to achieve good image quality, Pleiades-HR should first undergo an important 6 month commissioning phase period. This phase consists in calibrating and assessing the radiometric and geometric image quality to offer the best images to end users. This new satellite has benefited from technology improvements in various fields which make it stand out from other Earth observation satellites. In particular, its best-in-class agility performance enables new calibration and assessment techniques. This paper is dedicated to presenting these innovative techniques that have been tested for the first time for the Pleiades- HR radiometric commissioning. Radiometric activities concern compression, absolute calibration, detector normalization, and refocusing operations, MTF (Modulation Transfer Function assessment, signal-to-noise ratio (SNR estimation, and tuning of the ground processing parameters. The radiometric performances of each activity are summarized in this paper.

  16. preliminary geological and radiometric studies of granitoids of zing

    African Journals Online (AJOL)

    DJFLEX

    laboratory of Geology Department, Federal University of. Technology, Yola where they were thin sectioned and petrographically studied using a high magnification polarising microscope. Canada balsam was used as the mounting medium. Radiometric survey was carried out using a McPhar model TC-33A portable gamma ...

  17. Laboratory-based bidirectional reflectance distribution functions of radiometric tarps

    International Nuclear Information System (INIS)

    Georgiev, Georgi T.; Butler, James J.

    2008-01-01

    Laboratory-based bidirectional reflectance distribution functions (BRDFs) of radiometric tarp samples used in the vicarious calibration of Earth remote sensing satellite instruments are presented in this paper. The results illustrate the BRDF dependence on the orientation of the tarps' weft and warp threads. The study was performed using the GSFC scatterometer at incident zenith angles of 0 deg., 10 deg., and 30 deg.; scatter zenith angles from 0 deg. to 60 deg.; and scatter azimuth angles of 0 deg., 45 deg., 90 deg., 135 deg., and 180 deg.. The wavelengths were 485 nm, 550 nm, 633 nm, and 800 nm. The tarp's weft and warp dependence on BRDF is well defined at all measurement geometries and wavelengths. The BRDF difference can be as high as 8% at 0 deg. incident angle and 12% at 30 deg. incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps are reported. The backward scatter is well pronounced for the white samples. The black sample has well-pronounced forward scatter. The provided BRDF characterization of radiometric tarps is an excellent reference for anyone interested in using tarps for radiometric calibrations. The results are NIST traceable

  18. Laboratory-based bidirectional reflectance distribution functions of radiometric tarps.

    Science.gov (United States)

    Georgiev, Georgi T; Butler, James J

    2008-06-20

    Laboratory-based bidirectional reflectance distribution functions (BRDFs) of radiometric tarp samples used in the vicarious calibration of Earth remote sensing satellite instruments are presented in this paper. The results illustrate the BRDF dependence on the orientation of the tarps' weft and warp threads. The study was performed using the GSFC scatterometer at incident zenith angles of 0 degrees, 10 degrees, and 30 degrees; scatter zenith angles from 0 degrees to 60 degrees; and scatter azimuth angles of 0 degrees, 45 degrees, 90 degrees, 135 degrees, and 180 degrees. The wavelengths were 485 nm, 550 nm, 633 nm, and 800 nm. The tarp's weft and warp dependence on BRDF is well defined at all measurement geometries and wavelengths. The BRDF difference can be as high as 8% at 0 degrees incident angle and 12% at 30 degrees incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps are reported. The backward scatter is well pronounced for the white samples. The black sample has well-pronounced forward scatter. The provided BRDF characterization of radiometric tarps is an excellent reference for anyone interested in using tarps for radiometric calibrations. The results are NIST traceable.

  19. Radiometric Calibration of Osmi Imagery Using Solar Calibration

    Directory of Open Access Journals (Sweden)

    Dong-Han Lee

    2000-12-01

    Full Text Available OSMI (Ocean Scanning Multi-Spectral Imager raw image data (Level 0 were acquired and radiometrically corrected. We have applied two methods, using solar & dark calibration data from OSMI sensor and comparing with the SeaWiFS data, to the radiometric correction of OSMI raw image data. First, we could get the values of the gain and the offset for each pixel and each band from comparing the solar & dark calibration data with the solar input radiance values, calculated from the transmittance, BRDF (Bidirectional Reflectance Distribution Function and the solar incidence angle (¥â,¥è of OSMI sensor. Applying this calibration data to OSMI raw image data, we got the two odd results, the lower value of the radiometric corrected image data than the expected value, and the Venetian Blind Effect in the radiometric corrected image data. Second, we could get the reasonable results from comparing OSMI raw image data with the SeaWiFS data, and get a new problem of OSMI sensor.

  20. A novel ship CFAR detection algorithm based on adaptive parameter enhancement and wake-aided detection in SAR images

    Science.gov (United States)

    Meng, Siqi; Ren, Kan; Lu, Dongming; Gu, Guohua; Chen, Qian; Lu, Guojun

    2018-03-01

    Synthetic aperture radar (SAR) is an indispensable and useful method for marine monitoring. With the increase of SAR sensors, high resolution images can be acquired and contain more target structure information, such as more spatial details etc. This paper presents a novel adaptive parameter transform (APT) domain constant false alarm rate (CFAR) to highlight targets. The whole method is based on the APT domain value. Firstly, the image is mapped to the new transform domain by the algorithm. Secondly, the false candidate target pixels are screened out by the CFAR detector to highlight the target ships. Thirdly, the ship pixels are replaced by the homogeneous sea pixels. And then, the enhanced image is processed by Niblack algorithm to obtain the wake binary image. Finally, normalized Hough transform (NHT) is used to detect wakes in the binary image, as a verification of the presence of the ships. Experiments on real SAR images validate that the proposed transform does enhance the target structure and improve the contrast of the image. The algorithm has a good performance in the ship and ship wake detection.

  1. Detection and light enhancement of glucose oxidase adsorbed on porous silicon microcavities

    Energy Technology Data Exchange (ETDEWEB)

    Palestino, Gabriela [GES-UMR 5650, CNRS-Universite Montpellier II, Montpellier (France); Facultad de Ciencias Quimicas, Universidad Autonoma de San Luis Potosi, San Luis Potosi (Mexico); Martin, Marta; Legros, Rene; Cloitre, Thierry; Gergely, Csilla [GES-UMR 5650, CNRS-Universite Montpellier II, Montpellier (France); Agarwal, Vivechana [CIICAP, Universidad Autonoma del Estado de Morelos, Cuernavaca (Mexico); Zimanyi, Laszlo [EA4203, Faculte d' Odontologie, Universite Montpellier I, Montpellier (France); Institute of Biophysics, Biological Research Center, Hungarian Academy of Sciences, Szeged (Hungary)

    2009-07-15

    Porous silicon (PSi) structure is used as support material to detect protein infiltration and to induce fluorescence and second harmonic light enhancement from glucose oxidase (GOX). Functionalization and protein infiltration is monitored by specular reflectometry. Optical response enhancement of PSi microcavity structures compared to PSi single layers or Bragg mirrors is observed, when GOX is impregnated. Penetration of organic molecules along the PSi microcavity structure is demonstrated by energy dispersive X-ray profile. Enhanced fluorescence emission of GOX when adsorbed on PSi microcavity is evidenced by multi-photon microscopy (MPM). Second harmonic light generation is observed at some particular pores of PSi and subsequent resonance enhancement of the signal arising from the GOX adsorbed within the pores is detected. Our work evidences an improved device functionality of GOX-PSi microcavities due to strongly confined and localized light emission within these structures. This opens the way towards the application of PSi microcavity structures as amended biosensors based on their locally enhanced optical response. The second main achievement lies in the novelty of the used techniques. In contrast to the specular reflectometry used to monitor the macroscopic optical response of PSi structures, MPM presents a valuable alternative microscopic technique probing individual pores. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. The moon as a radiometric reference source for on-orbit sensor stability calibration

    Science.gov (United States)

    Stone, T.C.

    2009-01-01

    The wealth of data generated by the world's Earth-observing satellites, now spanning decades, allows the construction of long-term climate records. A key consideration for detecting climate trends is precise quantification of temporal changes in sensor calibration on-orbit. For radiometer instruments in the solar reflectance wavelength range (near-UV to shortwave-IR), the Moon can be viewed as a solar diffuser with exceptional stability properties. A model for the lunar spectral irradiance that predicts the geometric variations in the Moon's brightness with ???1% precision has been developed at the U.S. Geological Survey in Flagstaff, AZ. Lunar model results corresponding to a series of Moon observations taken by an instrument can be used to stabilize sensor calibration with sub-percent per year precision, as demonstrated by the Sea-viewing Wide Field-of-view Sensor (SeaWiFS). The inherent stability of the Moon and the operational model to utilize the lunar irradiance quantity provide the Moon as a reference source for monitoring radiometric calibration in orbit. This represents an important capability for detecting terrestrial climate change from space-based radiometric measurements.

  3. Effect of Multi-condition Training and Speech Enhancement Methods on Spoofing Detection

    DEFF Research Database (Denmark)

    Yu, Hong; Sarkar, Achintya Kumar; Thomsen, Dennis Alexander Lehmann

    2016-01-01

    enhancement methods on a state of-the-art spoofing detection system based on the dynamic linear frequency cepstral coefficients (LFCC) feature and a Gaussian mixture model maximum-likelihood (GMM-ML) classifier. In the experiment part we consider three additive noise types, Cantine, Babble and white Gaussian......Many researchers have demonstrated the good performance of spoofing detection systems under clean training and testing conditions. However, it is well known that the performance of speaker and speech recognition systems significantly degrades in noisy conditions. Therefore, it is of great interest...... to investigate the effect of noise on the performance of spoofing detection systems. In this paper, we investigate a multi-conditional training method where spoofing detection models are trained with a mix of clean and noisy data. In addition, we study the effect of different noise types as well as speech...

  4. Enzyme-enhanced fluorescence detection of DNA on etched optical fibers.

    Science.gov (United States)

    Niu, Shu-yan; Li, Quan-yi; Ren, Rui; Zhang, Shu-sheng

    2009-05-15

    A novel DNA biosensor based on enzyme-enhanced fluorescence detection on etched optical fibers was developed. The hybridization complex of DNA probe and biotinylated target was formed on the etched optical fiber, and was then bound with streptavidin labeled horseradish peroxidase (streptavidin-HRP). The target DNA was quantified through the fluorescent detection of bi-p,p'-4-hydroxyphenylacetic acid (DBDA) generated from the substrate 4-hydroxyphenylacetic acid (p-HPA) under the catalysis of HRP, with a detection limit of 1 pM and a linear range from 1.69 pM to 169 pM. It is facile to regenerate this sensor through surface treatment with concentrated urea solution. It was discovered that the sensor can retain 70% of its original activity after three detection-regeneration cycles.

  5. Detection of small surface defects using DCT based enhancement approach in machine vision systems

    Science.gov (United States)

    He, Fuqiang; Wang, Wen; Chen, Zichen

    2005-12-01

    Utilizing DCT based enhancement approach, an improved small defect detection algorithm for real-time leather surface inspection was developed. A two-stage decomposition procedure was proposed to extract an odd-odd frequency matrix after a digital image has been transformed to DCT domain. Then, the reverse cumulative sum algorithm was proposed to detect the transition points of the gentle curves plotted from the odd-odd frequency matrix. The best radius of the cutting sector was computed in terms of the transition points and the high-pass filtering operation was implemented. The filtered image was then inversed and transformed back to the spatial domain. Finally, the restored image was segmented by an entropy method and some defect features are calculated. Experimental results show the proposed small defect detection method can reach the small defect detection rate by 94%.

  6. Slow-light enhanced optical detection in liquid-infiltrated photonic crystals

    DEFF Research Database (Denmark)

    Pedersen, Martin Erland Vestergaard; Rishøj, Lars Søgaard; Steffensen, Henrik

    2007-01-01

    Slow-light enhanced optical detection in liquid-infiltrated photonic crystals is theoretically studied. Using a scattering-matrix approach and the Wigner–Smith delay time concept, we show that optical absorbance benefits both from slow-light phenomena as well as a high filling factor of the energy...... residing in the liquid. Utilizing strongly dispersive photonic crystal structures, we numerically demonstrate how liquid-infiltrated photonic crystals facilitate enhanced light–matter interactions, by potentially up to an order of magnitude. The proposed concept provides strong opportunities for improving...

  7. A novel solution for car traffic control based on radiometric microwave devices

    Science.gov (United States)

    Soldovieri, Francesco; Denisov, Alexander; Speziale, Victor

    2014-05-01

    The significant problem of traffic in big cities, connected with huge and building up quantity of automobile cars, demands for novel strategies, based on nonconventional solutions, in order to improve system traffic control, especially at crossroads. As well known, the usual solution is based on the time relay, which requires the installation of a fixed traffic interval (signal light switching) at a crossroad; this solution is low cost, but does not account for the actual traffic conditions. Therefore, in the recent years, attention is towards to new designs, where the monitoring of the and control of traffic is carried out by using various methods including, optical, the infrared, magnetic, radar tracking, acoustical ones. In this work, we discuss the deployment of high sensitivity radiometric systems and radiometers(sensor) in the microwave range [1, 2]. In fact, the radiometer as "sensor" can provide an always updated information about the car traffic in any weather condition and in absence or low visibility conditions. In fact, the radiometric sensor detects the cars thanks to the different behavior of the car roofs which reflect the cold sky whereas the road asphalt is visible as warm object (at around outside temperature). [1] A. G. Denisov, V. P. Gorishnyak, S. E. Kuzmin et al., "Some experiments concerning resolution of 32 sensors passive 8mm wave imaging system," in Proceedings of the International Symposium on Space Terahertz Technology (ISSTT '09), Charlottesville, Va, USA, April 2009. [2] F. Soldovieri, A. Natale, V. Gorishnyak, A. Pavluchenko, A. Denisov, and L. Chen, "Radiometric Imaging for Monitoring and Surveillance Issues," International Journal of Antennas and Propagation, vol. 2013, Article ID 272561, 8 pages, 2013. doi:10.1155/2013/272561.

  8. Detection of Surface-Linked Polychlorinated Biphenyls using Surface-Enhanced Raman Scattering Spectroscopy

    DEFF Research Database (Denmark)

    Rindzevicius, Tomas; Barten, Jan; Vorobiev, Mikhail

    2017-01-01

    We present an improved procedure for analytical detection of toxic polychlorinated biphenyls (PCB) using surface-enhanced Raman scattering (SERS) spectroscopy. A gold-capped silicon nanopillar substrate was utilized to concentrate PCB molecules within an area of high electromagnetic fields through...... formation of microsized nanopillar clusters, and consequently, so-called “hot spots” can be formed. In order to improve PCB detection limit, 3,3',4,4'-tetrachlorobiphenyl (PCB77) compounds were chemically modified with a – SCH3 (PCB77-SCH3) group. Experimental and numerical analysis of vibrational modes...

  9. The detection of climate change due to the enhanced greenhouse effect

    Science.gov (United States)

    Schiffer, Robert A.; Unninayar, Sushel

    1991-01-01

    The greenhouse effect is accepted as an undisputed fact from both theoretical and observational considerations. In Earth's atmosphere, the primary greenhouse gas is water vapor. The specific concern today is that increasing concentrations of anthropogenically introduced greenhouse gases will, sooner or later, irreversibly alter the climate of Earth. Detecting climate change has been complicated by uncertainties in historical observations and measurements. Thus, the primary concern for the GEDEX project is how can climate change and enhanced greenhouse effects be unambiguously detected and quantified. Specifically examined are the areas of: Earth surface temperature; the free atmosphere (850 millibars and above); space-based measurements; measurement uncertainties; and modeling the observed temperature record.

  10. The detection of climate change due to the enhanced greenhouse effect

    International Nuclear Information System (INIS)

    Schiffer, R.A.; Unninayar, S.

    1991-01-01

    The greenhouse effect is accepted as an undisputed fact from both theoretical and observational considerations. In Earth's atmosphere, the primary greenhouse gas is water vapor. The specific concern today is that increasing concentrations of anthropogenically introduced greenhouse gases will, sooner or later, irreversibly alter the climate of Earth. Detecting climate change has been complicated by uncertainties in historical observations and measurements. Thus, the primary concern for the GEDEX project is how can climate change and enhanced greenhouse effects be unambiguously detected and quantified. Specifically examined are the areas of: Earth surface temperature; the free atmosphere (850 millibars and above); space-based measurements; measurement uncertainties; and modeling the observed temperature record

  11. Detection of nerve gases using surface-enhanced Raman scattering substrates with high droplet adhesion

    DEFF Research Database (Denmark)

    Hakonen, Aron; Rindzevicius, Tomas; Schmidt, Michael Stenbæk

    2016-01-01

    Threats from chemical warfare agents, commonly known as nerve gases, constitute a serious security issue of increasing global concern because of surging terrorist activity worldwide. However, nerve gases are difficult to detect using current analytical tools and outside dedicated laboratories. Here...... adhesion and nanopillar clustering due to elasto-capillary forces, resulting in enrichment of target molecules in plasmonic hot-spots with high Raman enhancement. The results may pave the way for strategic life-saving SERS detection of chemical warfare agents in the field....

  12. Surface-enhanced Raman spectroscopy for uranium detection and analysis in environmental samples

    International Nuclear Information System (INIS)

    Ruan Chuanmin; Luo Wensui; Wang Wei; Gu Baohua

    2007-01-01

    Techniques for rapid screening of uranium in environmental samples are needed, and this study entails the development of surface-enhanced Raman scattering (SERS) for analyzing uranium in aqueous media with improved sensitivity and reproducibility. A new SERS substrate based on (aminomethyl)phosphonic acid (APA)-modified gold nanoparticles was found to give greater than three orders of magnitude SERS enhancement compared with unmodified bare gold nanoparticles. Intensities of uranyl band at about 830 cm -1 were proportional to the concentrations of uranium in solution, especially at relatively low concentrations ( -5 M). A detection limit of ∼8 x 10 -7 M was achieved with a good reproducibility since the measurement was performed directly in dispersed aqueous suspension. Without pretreatment, the technique was successfully employed for detecting uranium in a highly contaminated groundwater with a low pH, high dissolved salts (e.g., nitrate, sulfate, calcium and aluminum) and total organic carbon

  13. Surface-Enhanced Raman Spectroscopy for Uranium Detection and Analysis in Environmental Samples

    International Nuclear Information System (INIS)

    Ruan, Chuanmin; Luo, Wensui; Wang, Wei; Gu, Baohua

    2007-01-01

    Techniques for rapid screening of uranium in environmental samples are needed, and this study entails the development of surface-enhanced Raman scattering (SERS) for analyzing uranium in aqueous media with improved sensitivity and reproducibility. A new SERS substrate based on (aminomethyl)phosphonic acid (APA)-modified gold nanoparticles was found to give greater than three orders of magnitude SERS enhancement compared with unmodified bare gold nanoparticles. Intensities of uranyl band at about 830 cm-1 were proportional to the concentrations of uranium in solution, especially at relatively low concentrations (<10-5 M). A detection limit of ∼8 e10-7 M was achieved with a good reproducibility since the measurement was performed directly in dispersed aqueous suspension. Without pretreatment, the technique was successfully employed for the detection of uranium in a highly contaminated groundwater with a low pH, high dissolved salts (e.g., nitrate, sulfate, calcium and aluminum) and total organic carbon

  14. Real-time 3-dimensional contrast-enhanced ultrasound in detecting hemorrhage of blunt renal trauma.

    Science.gov (United States)

    Xu, Rui-Xue; Li, Ye-Kuo; Li, Ting; Wang, Sha-Sha; Yuan, Gui-Zhong; Zhou, Qun-Fang; Zheng, Hai-Rong; Yan, Fei

    2013-10-01

    The objective of this study is to evaluate the diagnostic value of real-time 3-dimensional contrast-enhanced ultrasound in the hemorrhage of blunt renal trauma. Eighteen healthy New Zealand white rabbits were randomly divided into 3 groups. Blunt renal trauma was performed on each group by using minitype striker. Ultrasonography, color Doppler flow imaging, and contrast-enhanced 2-dimensional and real-time 3-dimensional ultrasound were applied before and after the strike. The time to shock and blood pressure were subjected to statistical analysis. Then, a comparative study of ultrasound and pathology was carried out. All the struck kidneys were traumatic. In the ultrasonography, free fluid was found under the renal capsule. In the color Doppler flow imaging, active hemorrhage was not identified. In 2-dimensional contrast-enhanced ultrasound, active hemorrhage of the damaged kidney was characterized. Real-time 3-dimensional contrast-enhanced ultrasound showed a real-time and stereoscopic ongoing bleeding of the injured kidney. The wider the hemorrhage area in 4-dimensional contrast-enhanced ultrasound was, the faster the blood pressure decreased. Real-time 3-dimensional contrast-enhanced ultrasound is a promising noninvasive tool for stereoscopically and vividly detecting ongoing hemorrhage of blunt renal trauma in real time. © 2013.

  15. Radiometric and spectral calibrations of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) using principle component analysis

    Science.gov (United States)

    Tian, Jialin; Smith, William L.; Gazarik, Michael J.

    2008-10-01

    The ultimate remote sensing benefits of the high resolution Infrared radiance spectrometers will be realized with their geostationary satellite implementation in the form of imaging spectrometers. This will enable dynamic features of the atmosphere's thermodynamic fields and pollutant and greenhouse gas constituents to be observed for revolutionary improvements in weather forecasts and more accurate air quality and climate predictions. As an important step toward realizing this application objective, the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstration Unit (EDU) was successfully developed under the NASA New Millennium Program, 2000-2006. The GIFTS-EDU instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw GIFTS interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. The radiometric calibration is achieved using internal blackbody calibration references at ambient (260 K) and hot (286 K) temperatures. The absolute radiometric performance of the instrument is affected by several factors including the FPA off-axis effect, detector/readout electronics induced nonlinearity distortions, and fore-optics offsets. The GIFTS-EDU, being the very first imaging spectrometer to use ultra-high speed electronics to readout its large area format focal plane array detectors, operating at wavelengths as large as 15 microns, possessed non-linearity's not easily removable in the initial calibration process. In this paper, we introduce a refined calibration technique that utilizes Principle Component (PC) analysis to compensate for instrument distortions and artifacts remaining after the initial radiometric calibration process, thus, further enhance the absolute calibration accuracy. This method is

  16. Mine detection using SF-GPR: A signal processing approach for resolution enhancement and clutter reduction

    DEFF Research Database (Denmark)

    Karlsen, Brian; Jakobsen, Kaj Bjarne; Larsen, Jan

    2001-01-01

    Proper clutter reduction is essential for Ground Penetrating Radar data since low signal-to-clutter ratio prevent correct detection of mine objects. A signal processing approach for resolution enhancement and clutter reduction used on Stepped-Frequency Ground Penetrating Radar (SF-GPR) data is pr....... The clutter reduction method is based on basis function decomposition of the SF-GPR time-series from which the clutter and the signal are separated....

  17. Using a silver-enhanced microarray sandwich structure to improve SERS sensitivity for protein detection.

    Science.gov (United States)

    Gu, Xuefang; Yan, Yuerong; Jiang, Guoqing; Adkins, Jason; Shi, Jian; Jiang, Guomin; Tian, Shu

    2014-03-01

    A simple and sensitive method, based on surface-enhanced Raman scattering (SERS), for immunoassay and label-free protein detection is reported. A series of bowl-shaped silver cavity arrays were fabricated by electrodeposition using a self-assembled polystyrene spheres template. The reflection spectra of these cavity arrays were recorded as a function of film thickness, and then correlated with SERS enhancement using sodium thiophenolate as the probe molecule. The results reveal that SERS enhancement can be maximized when the frequency of both the incident laser and the Raman scattering approach the frequency of the localized surface plasmon resonance. The optimized array was then used as the bottom layer of a silver nanoparticle-protein-bowl-shaped silver cavity array sandwich. The second layer of silver was introduced by the interactions between the proteins in the middle layer of the sandwich architecture and silver nanoparticles. Human IgG bound to the surface of this microcavity array can retain its recognition function. With the Raman reporter molecules labeled on the antibody, a detection limit down to 0.1 ng mL(-1) for human IgG is easily achieved. Furthermore, the SERS spectra of label-free proteins (catalase, cytochrome C, avidin and lysozyme) from the assembled sandwich have excellent reproducibility and high quality. The results reveal that the proposed approach has potential for use in qualitative and quantitative detection of biomolecules.

  18. Improved focal liver lesion detection by increasing flip angle during gadoxetic acid-enhancement in MRI

    International Nuclear Information System (INIS)

    Lee, Se Jy; Kim, Young Keun

    2015-01-01

    To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)’s enhanced MR imaging with a flip angle (FA) of 30° compared with a 11°. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA 11° and 30° images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA 30° images was found to be superior than FA 11°, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA 30° image(p<0.05) was better than FA 11° therefore, the FA 30° improves the focal liver lesion detection. FA 30° of MR image can detect liver lesion more sensitively than the existing FA11° image after GA contrast enhancement at 15 minute time point

  19. Detection of DNA hybridization based on SnO2 nanomaterial enhanced fluorescence

    International Nuclear Information System (INIS)

    Gu Cuiping; Huang Jiarui; Ni Ning; Li Minqiang; Liu Jinhuai

    2008-01-01

    In this paper, enhanced fluorescence emissions were firstly investigated based on SnO 2 nanomaterial, and its application in the detection of DNA hybridization was also demonstrated. The microarray of SnO 2 nanomaterial was fabricated by the vapour phase transport method catalyzed by patterned Au nanoparticles on a silicon substrate. A probe DNA was immobilized on the substrate with patterned SnO 2 nanomaterial, respectively, by covalent and non-covalent linking schemes. When a fluorophore labelled target DNA was hybridized with a probe DNA on the substrate, fluorescence emissions were only observed on the surface of SnO 2 nanomaterial, which indicated the property of enhancing fluorescence signals from the SnO 2 nanomaterial. By comparing the different fluorescence images from covalent and non-covalent linking schemes, the covalent method was confirmed to be more effective for immobilizing a probe DNA. With the combined use of SnO 2 nanomaterial and the covalent linking scheme, the target DNA could be detected at a very low concentration of 10 fM. And the stability of SnO 2 nanomaterial under the experimental conditions was also compared with silicon nanowires. The findings strongly suggested that SnO 2 nanomaterial could be extensively applied in detections of biological samples with enhancing fluorescence property and high stability

  20. Radiometric Correction of Close-Range Spectral Image Blocks Captured Using an Unmanned Aerial Vehicle with a Radiometric Block Adjustment

    Directory of Open Access Journals (Sweden)

    Eija Honkavaara

    2018-02-01

    Full Text Available Unmanned airborne vehicles (UAV equipped with novel, miniaturized, 2D frame format hyper- and multispectral cameras make it possible to conduct remote sensing measurements cost-efficiently, with greater accuracy and detail. In the mapping process, the area of interest is covered by multiple, overlapping, small-format 2D images, which provide redundant information about the object. Radiometric correction of spectral image data is important for eliminating any external disturbance from the captured data. Corrections should include sensor, atmosphere and view/illumination geometry (bidirectional reflectance distribution function—BRDF related disturbances. An additional complication is that UAV remote sensing campaigns are often carried out under difficult conditions, with varying illumination conditions and cloudiness. We have developed a global optimization approach for the radiometric correction of UAV image blocks, a radiometric block adjustment. The objective of this study was to implement and assess a combined adjustment approach, including comprehensive consideration of weighting of various observations. An empirical study was carried out using imagery captured using a hyperspectral 2D frame format camera of winter wheat crops. The dataset included four separate flights captured during a 2.5 h time period under sunny weather conditions. As outputs, we calculated orthophoto mosaics using the most nadir images and sampled multiple-view hyperspectral spectra for vegetation sample points utilizing multiple images in the dataset. The method provided an automated tool for radiometric correction, compensating for efficiently radiometric disturbances in the images. The global homogeneity factor improved from 12–16% to 4–6% with the corrections, and a reduction in disturbances could be observed in the spectra of the object points sampled from multiple overlapping images. Residuals in the grey and white reflectance panels were less than 5% of the

  1. Label-Free Ag+ Detection by Enhancing DNA Sensitized Tb3+ Luminescence

    Directory of Open Access Journals (Sweden)

    Kimberly Kleinke

    2016-08-01

    Full Text Available In this work, the effect of Ag+ on DNA sensitized Tb3+ luminescence was studied initially using the Ag+-specific RNA-cleaving DNAzyme, Ag10c. While we expected to observe luminescence quenching by Ag+, a significant enhancement was produced. Based on this observation, simple DNA oligonucleotide homopolymers were used with systematically varied sequence and length. We discovered that both poly-G and poly-T DNA have a significant emission enhancement by Ag+, while the absolute intensity is stronger with the poly-G DNA, indicating that a G-quadruplex DNA is not required for this enhancement. Using the optimized length of the G7 DNA (an oligo constituted with seven guanines, Ag+ was measured with a detection limit of 57.6 nM. The signaling kinetics, G7 DNA conformation, and the binding affinity of Tb3+ to the DNA in the presence or absence of Ag+ are also studied to reveal the mechanism of emission enhancement. This observation is useful not only for label-free detection of Ag+, but also interesting for the rational design of new biosensors using Tb3+ luminescence.

  2. Detection of cavernous transformation of the portal vein by contrast-enhanced ultrasound.

    Science.gov (United States)

    Hwang, Misun; Thimm, Matthew A; Guerrerio, Anthony L

    2018-06-01

    Cavernous transformation of the portal vein can be missed on color Doppler exam or arterial phase cross-sectional imaging due to their slow flow and delayed enhancement. Contrast-enhanced ultrasound (CEUS) offers many advantages over other imaging techniques and can be used to successfully detect cavernous transformations of the portal vein. A 10-month-old female was followed for repeat episodes of hematemesis. Computed tomography angiography (CTA) and magnetic resonance arteriogram (MRA) and portal venography were performed. Color Doppler exam of the portal vein was performed followed by administration of Lumason, a microbubble US contrast agent. Magnetic resonance arteriogram, CTA, and color Doppler exam at the time of initial presentation was unremarkable without obvious vascular malformation within the limits of motion degraded exam. At 8-month follow-up, esophagogastroduodenoscopy revealed a vascular malformation in the distal esophagus which was sclerosed. At 6 month after sclerosis of the lesion, portal venography revealed occlusion of the portal vein with extensive collateralization. Color Doppler revealed subtle hyperarterialization and periportal collaterals. CEUS following color Doppler exam demonstrated extensive enhancement of periportal collaterals. Repeat color Doppler after contrast administration demonstrated extensive Doppler signal in the collateral vessels, suggestive of cavernous transformation. We describe a case of cavernous transformation of the portal vein missed on initial color Doppler, CTA and MRA, but detected with contrast-enhanced ultrasound technique.

  3. Three-dimensional hybrid silicon nanostructures for surface enhanced Raman spectroscopy based molecular detection

    Science.gov (United States)

    Vendamani, V. S.; Nageswara Rao, S. V. S.; Venugopal Rao, S.; Kanjilal, D.; Pathak, A. P.

    2018-01-01

    Three-dimensional silver nanoparticles decorated vertically aligned Si nanowires (Si NWs) are effective surface-enhanced Raman spectroscopy (SERS) substrates for molecular detection at low concentration levels. The length of Si NWs prepared by silver assisted electroless etching is increased with an increase in etching time, which resulted in the reduced optical reflection in the visible region. These substrates were tested and optimized by measuring the Raman spectrum of standard dye Rhodamine 6G (R6G) of 10 nM concentration. Further, effective SERS enhancements of ˜105 and ˜104 were observed for the cytosine protein (concentration of 50 μM) and ammonium perchlorate (oxidizer used in explosives composition with a concentration of 10 μM), respectively. It is established that these three-dimensional SERS substrates yielded considerably higher enhancement factors for the detection of R6G when compared to previous reports. The sensitivity can further be increased and optimized since the Raman enhancement was found to increase with an increase in the density of silver nanoparticles decorated on the walls of Si NWs.

  4. A study on the radiometric method for evaluating element migration from plastic packagings to its contents

    International Nuclear Information System (INIS)

    Soares, Eufemia Paez

    2008-01-01

    migration detection limits were determined. Results from the analyses of the neutron irradiated plastic packagings by differential scanning calorimetry and Fourier transform infrared spectroscopy showed that in high density polyethylene packagings oxidative degradation can occur. Among the main advantages of the radiometric method application for element migration evaluation are its simplicity, no need of blank analysis and the possibility to obtain element migration to the food itself. The results obtained indicated the potentiality of using this method in the element migration evaluation from the plastic packagings to their contents. (author)

  5. Sky camera imagery processing based on a sky classification using radiometric data

    International Nuclear Information System (INIS)

    Alonso, J.; Batlles, F.J.; López, G.; Ternero, A.

    2014-01-01

    As part of the development and expansion of CSP (concentrated solar power) technology, one of the most important operational requirements is to have complete control of all factors which may affect the quantity and quality of the solar power produced. New developments and tools in this field are focused on weather forecasting improving both operational security and electricity production. Such is the case with sky cameras, devices which are currently in use in some CSP plants and whose use is expanding in the new technology sector. Their application is mainly focused on cloud detection, estimating their movement as well as their influence on solar radiation attenuation indeed, the presence of clouds is the greatest factor involved in solar radiation attenuation. The aim of this work is the detection and analysis of clouds from images taken by a TSI-880 model sky. In order to obtain accurate image processing, three different models were created, based on a previous sky classification using radiometric data and representative sky conditions parameters. As a consequence, the sky can be classified as cloudless, partially-cloudy or overcast, delivering an average success rate of 92% in sky classification and cloud detection. - Highlights: • We developed a methodology for detection of clouds in total sky imagery (TSI-880). • A classification of sky is presented according to radiometric data and sky parameters. • The sky can be classified as cloudless, partially cloudy and overcast. • The images processing is based on the sky classification for the detection of clouds. • The average success of the developed model is around 92%

  6. Implementation of molecularly imprinted polymer beads for surface enhanced Raman detection.

    Science.gov (United States)

    Kamra, Tripta; Zhou, Tongchang; Montelius, Lars; Schnadt, Joachim; Ye, Lei

    2015-01-01

    Molecularly imprinted polymers (MIPs) have a predesigned molecular recognition capability that can be used to build robust chemical sensors. MIP-based chemical sensors allow label-free detection and are particularly interesting due to their simple operation. In this work we report the use of thiol-terminated MIP microspheres to construct surfaces for detection of a model organic analyte, nicotine, by surface enhanced Raman scattering (SERS). The nicotine-imprinted microspheres are synthesized by RAFT precipitation polymerization and converted into thiol-terminated microspheres through aminolysis. The thiol groups on the MIP surface allow the microspheres to be immobilized on a gold-coated substrate. Three different strategies are investigated to achieve surface enhanced Raman scattering in the vicinity of the imprinted sites: (1) direct sputtering of gold nanoparticles, (2) immobilization of gold colloids through the MIP's thiol groups, and (3) trapping of the MIP microspheres in a patterned SERS substrate. For the first time we show that large MIP microspheres can be turned into selective SERS surfaces through the three different approaches of assembly. The MIP-based sensing surfaces are used to detect nicotine to demonstrate the proof of concept. As synthesis and surface functionalization of MIP microspheres and nanoparticles are well established, the methods reported in this work are handy and efficient for constructing label-free chemical sensors, in particular for those based on SERS detection.

  7. Detection of amino acid neurotransmitters by surface enhanced Raman scattering and hollow core photonic crystal fiber

    Science.gov (United States)

    Tiwari, Vidhu S.; Khetani, Altaf; Monfared, Ali Momenpour T.; Smith, Brett; Anis, Hanan; Trudeau, Vance L.

    2012-03-01

    The present work explores the feasibility of using surface enhanced Raman scattering (SERS) for detecting the neurotransmitters such as glutamate (GLU) and gamma-amino butyric acid (GABA). These amino acid neurotransmitters that respectively mediate fast excitatory and inhibitory neurotransmission in the brain, are important for neuroendocrine control, and upsets in their synthesis are also linked to epilepsy. Our SERS-based detection scheme enabled the detection of low amounts of GLU (10-7 M) and GABA (10-4 M). It may complement existing techniques for characterizing such kinds of neurotransmitters that include high-performance liquid chromatography (HPLC) or mass spectrography (MS). This is mainly because SERS has other advantages such as ease of sample preparation, molecular specificity and sensitivity, thus making it potentially applicable to characterization of experimental brain extracts or clinical diagnostic samples of cerebrospinal fluid and saliva. Using hollow core photonic crystal fiber (HC-PCF) further enhanced the Raman signal relative to that in a standard cuvette providing sensitive detection of GLU and GABA in micro-litre volume of aqueous solutions.

  8. Nanotextured thin films for detection of chemicals by surface enhanced Raman scattering

    Science.gov (United States)

    Korivi, Naga; Jiang, Li; Ahmed, Syed; Nujhat, Nabila; Idrees, Mohanad; Rangari, Vijaya

    2017-11-01

    We report on the development of large area, nanostructured films that function as substrates for surface enhanced Raman scattering (SERS) detection of chemicals. The films are made of polyethylene terephthalate layers partially embedded with multi-walled carbon nanotubes and coated with a thin layer of gold. The films are fabricated by a facile method involving spin-coating, acid dip, and magnetron sputtering. The films perform effectively as SERS substrates when used in the detection of dye pollutants such as Congo red dye, with an enhancement factor of 1.1  ×  106 and a detection limit of 10-7 M which is the lowest reported for CR detection by freestanding SERS film substrates. The films have a long shelf life, and cost US0.20 per cm2 of active area, far less than commercially available SERS substrates. This is the first such work on the use of a polymer layer modified with carbon nanotubes to create a nano-scale texture and arbitrary ‘hot-spots’, contributing to the SERS effect.

  9. Smart detection of microRNAs through fluorescence enhancement on a photonic crystal.

    Science.gov (United States)

    Pasquardini, L; Potrich, C; Vaghi, V; Lunelli, L; Frascella, F; Descrovi, E; Pirri, C F; Pederzolli, C

    2016-04-01

    The detection of low abundant biomarkers, such as circulating microRNAs, demands innovative detection methods with increased resolution, sensitivity and specificity. Here, a biofunctional surface was implemented for the selective capture of microRNAs, which were detected through fluorescence enhancement directly on a photonic crystal. To set up the optimal biofunctional surface, epoxy-coated commercially available microscope slides were spotted with specific anti-microRNA probes. The optimal concentration of probe as well as of passivating agent were selected and employed for titrating the microRNA hybridization. Cross-hybridization of different microRNAs was also tested, resulting negligible. Once optimized, the protocol was adapted to the photonic crystal surface, where fluorescent synthetic miR-16 was hybridized and imaged with a dedicated equipment. The photonic crystal consists of a dielectric multilayer patterned with a grating structure. In this way, it is possible to take advantage from both a resonant excitation of fluorophores and an angularly redirection of the emitted radiation. As a result, a significant fluorescence enhancement due to the resonant structure is collected from the patterned photonic crystal with respect to the outer non-structured surface. The dedicated read-out system is compact and based on a wide-field imaging detection, with little or no optical alignment issues, which makes this approach particularly interesting for further development such as for example in microarray-type bioassays. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Stimuli-Responsive Nanodiamond-Based Biosensor for Enhanced Metastatic Tumor Site Detection.

    Science.gov (United States)

    Wang, Xin; Gu, Mengjie; Toh, Tan Boon; Abdullah, Nurrul Lissa Binti; Chow, Edward Kai-Hua

    2018-02-01

    Metastasis is often critical to cancer progression and linked to poor survival and drug resistance. Early detection of metastasis, as well as identification of metastatic tumor sites, can improve cancer patient survival. Thus, developing technology to improve the detection of cancer metastasis biomarkers can improve both diagnosis and treatment. In this study, we investigated the use of nanodiamonds to develop a stimuli-responsive metastasis detection complex that utilizes matrix metalloproteinase 9 (MMP9) as a metastasis biomarker, as MMP9 increased expression has been shown to be indicative of metastasis. The nanodiamond-MMP9 biosensor complex consists of nanodiamonds functionalized with MMP9-specific fluorescent-labeled substrate peptides. Using this design, protease activity of MMP9 can be accurately measured and correlated to MMP9 expression. The nanodiamond-MMP9 biosensor also demonstrated an enhanced ability to protect the base sensor peptide from nonspecific serum protease cleavage. This enhanced peptide stability, combined with a quantitative stimuli-responsive output function, provides strong evidence for the further development of a nanodiamond-MMP9 biosensor for metastasis site detection. More importantly, this work provides the foundation for use of nanodiamonds as a platform for stimuli-responsive biosensors and theranostic complexes that can be implemented across a wide range of biomedical applications.

  11. Enhanced UV light detection using wavelength-shifting properties of Silicon nanoparticles

    International Nuclear Information System (INIS)

    Magill, S.; Xie, J.; Nayfeh, M.; Fizari, M.; Malloy, J.; Maximenko, Y.; Yu, H.

    2015-01-01

    Detection of UV photons is becoming increasingly necessary with the use of noble gases and liquids in elementary particle experiments. Cerenkov light in crystals and glasses, scintillation light in neutrino, dark matter, and rare decay experiments all require sensitivity to UV photons. New sensor materials are needed that can directly detect UV photons and/or absorb UV photons and re-emit light in the visible range measurable by existing photosensors. It has been shown that silicon nanoparticles are sensitive to UV light in a wavelength range around ∼ 200 nm. UV light is absorbed and re-emitted at wavelengths in the visible range depending on the size of the nanoparticles. Initial tests of the wavelength-shifting properties of silicon nanoparticles are presented here that indicate by placing a film of nanoparticles in front of a standard visible-wavelength detecting photosensor, the response of the sensor is significantly enhanced at wavelengths < 320 nm

  12. Enhancement of crack detection in stud bolts of nuclear reactor by ultrasonic signal processing technique

    International Nuclear Information System (INIS)

    Lee, J.H.; Oh, W.D.; Choi, S.W.; Park, M.H.

    2004-01-01

    'Full-text:' The stud bolts is one of the most critical parts for safety of reactor vessels in the nuclear power plants. However, in the application of ultrasonic technique for crack detection in stud bolt, some difficulties encountered are classification of crack signal from the signals reflected from threads part in stud bolt. In this study, shadow effect technique combined with new signal processing method is Investigated to enhance the detectability of small crack initiated from root of thread in stud bolt. The key idea of signal processing is based on the fact that the shape of waveforms from the threads is uniform since the shape of the threads in a bolt is same. If some cracks exist in the thread, the flaw signals are different to the reference signals. It is demonstrated that the small flaws are efficiently detected by novel ultrasonic technique combined with this new signal processing concept. (author)

  13. Global Positioning Radiometric Scanner System. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    2001-01-01

    The US DOE continually seeks safer and more cost-effective technologies for use in decontamination and decommissioning (D and D) of nuclear facilities. To this end, the Deactivation and Decommissioning Focus Area (DDFA) of the DOE OST sponsors the Large Scale Demonstration and Deployment Projects (LSDDP). At these LSDDPs, developers and vendors of improved or innovative technologies showcase products that are potentially beneficial to the DOE projects and to others in the D and D community. Benefits sought include decreased health and safety risks to personnel and the environment, increased productivity, and decreased costs of operation. The Idaho National Engineering and Environmental Laboratory (INEEL) LSDDP generated a list of statements defining specific needs or problems where improved technology could be incorporated into ongoing D and D tasks. One of the stated needs was for developing technologies that would reduce costs and shorten DDOE/EM--0552DOE/EM--0552 and D schedules by providing radiological characterizations to meet the free-release criteria. The Global Positioning Radiometric Scanner (GPRS system shown in Figure 1) utilizes a detection system; a portable computer, a differential global positioning system (d-gps), and a four wheel drive vehicle. Once the survey data has been collected, a software program called GeoSofttrademark generates a graphical representation of the radiological contamination extent. Baseline technology involves gridding the area and hand surveying each grid. This demonstration investigated the associated costs and the required time to evaluate the radiological characterization data from the GPRS with respect to the baseline technology. The GPRS system performs in-situ, real-time analyses to identify the extent of radiological contamination. Benefits expected from using the new innovative technology (GPRS) include: Reduced labor hours associated with performing the survey; Increased number of survey data points; Reduced

  14. Ten years of radiometric monitoring in water samples in Uruguay potables plants

    International Nuclear Information System (INIS)

    Perruni, P.

    2000-01-01

    The work exposes the summary of having been radiometrics obtained during the last 10 years in several water treatment plants of the national territory, with the purpose of determining if in the total dose to the one that this exposed one naturally the population of the country, is important the contribution of polluting radioactives in the drinkable water, in function of the geographical area and the time of the year. The investigation is framed inside the Program of Control Radiometrics of Products of Fission in waters, floors, foods and aerosols of the Uruguay developed by the Radiochemistry Department, of the Nuclear Research Center, Montevideo (UY) The samples of water filter, they process and they analyze according to laboratory protocols, had duplicated by each plant, parallel with radio-active, white bottom measures and standards. The results net average obtained for each factory, gave below the one it limits of detection: 2 BQ/Kg for geometry Marinelli and 0.02 BQ/g for plane geometry, with 99,3% of dependability (standard 3 deviations), very below the maximum values admitted by International Organisms (WHO, FAO, ICRP) [es

  15. Combined gadoxetic acid and gadofosveset enhanced liver MRI for detection and characterization of liver metastases

    International Nuclear Information System (INIS)

    Bannas, Peter; Bookwalter, Candice A.; Ziemlewicz, Tim; Munoz del Rio, Alejandro; Potretzke, Theodora A.; Motosugi, Utaroh; Nagle, Scott K.; Reeder, Scott B.

    2017-01-01

    To compare gadoxetic acid alone and combined gadoxetic acid/gadofosveset trisodium-enhanced liver MRI for detection of metastases and differentiation of metastases from haemangiomas. Ninety-one patients underwent gadoxetic acid-enhanced liver MRI before and after additional injection of gadofosveset. First, two readers retrospectively identified metastases on gadoxetic acid alone enhanced delayed hepatobiliary phase T1-weighted images together with all other MR images (dynamic images, T2-weighted images, diffusion-weighted images). Second, readers assessed additional T1-weighted images obtained after administration of gadofosveset trisodium. For both interpretations, readers rated lesion conspicuity and confidence in differentiating metastases from haemangiomas. Results were compared using alternative free-response receiver-operating characteristic (AFROC) and conventional ROC methods. Histology and follow-up served as reference standard. There were 145 metastases and 16 haemangiomas. Both readers detected more metastases using combined gadoxetic acid/gadofosveset (reader 1 = 130; reader 2 = 124) compared to gadoxetic acid alone (reader 1 = 104; reader 2 = 103). Sensitivity of combined gadoxetic acid/gadofosveset (reader 1 = 90 %; reader 2 = 86 %) was higher than that of gadoxetic acid alone (reader 1 = 72 %; reader 2 = 71 %, both P < 0.01). AFROC-AUC was higher for the combined technique (0.92 vs. 0.86, P < 0.001). Sensitivity for correct differentiation of metastases from haemangiomas was higher for the combined technique (reader 1 = 98 %; reader 2 = 99 % vs. reader 1 = 86 %; reader 2 = 91 %, both P < 0.01). ROC-AUC was significantly higher for the combined technique (reader 1 = 1.00; reader 2 = 1.00 vs. reader 1 = 0.87; reader 2 = 0.92, both P < 0.01). Combined gadoxetic acid/gadofosveset-enhanced MRI improves detection and characterization of liver metastases compared to gadoxetic acid alone. (orig.)

  16. Combined gadoxetic acid and gadofosveset enhanced liver MRI for detection and characterization of liver metastases

    Energy Technology Data Exchange (ETDEWEB)

    Bannas, Peter [University of Wisconsin-Madison, Department of Radiology, Madison, WI (United States); University Medical Center Hamburg-Eppendorf, Department of Radiology, University Hospital, Hamburg (Germany); Bookwalter, Candice A.; Ziemlewicz, Tim; Munoz del Rio, Alejandro; Potretzke, Theodora A. [University of Wisconsin-Madison, Department of Radiology, Madison, WI (United States); Motosugi, Utaroh [University of Wisconsin-Madison, Department of Radiology, Madison, WI (United States); University of Yamanashi, Department of Radiology, Yamanashi (Japan); Nagle, Scott K. [University of Wisconsin-Madison, Department of Radiology, Madison, WI (United States); University of Wisconsin-Madison, Department of Medical Physics, Madison, WI (United States); University of Wisconsin-Madison, Department of Pediatrics, Madison, WI (United States); Reeder, Scott B. [University of Wisconsin-Madison, Department of Radiology, Madison, WI (United States); University of Wisconsin-Madison, Department of Medical Physics, Madison, WI (United States); University of Wisconsin-Madison, Department of Biomedical Engineering, Madison, WI (United States); University of Wisconsin-Madison, Department of Medicine, Madison, WI (United States); University of Wisconsin-Madison, Department of Emergency Medicine, Madison, WI (United States)

    2017-01-15

    To compare gadoxetic acid alone and combined gadoxetic acid/gadofosveset trisodium-enhanced liver MRI for detection of metastases and differentiation of metastases from haemangiomas. Ninety-one patients underwent gadoxetic acid-enhanced liver MRI before and after additional injection of gadofosveset. First, two readers retrospectively identified metastases on gadoxetic acid alone enhanced delayed hepatobiliary phase T1-weighted images together with all other MR images (dynamic images, T2-weighted images, diffusion-weighted images). Second, readers assessed additional T1-weighted images obtained after administration of gadofosveset trisodium. For both interpretations, readers rated lesion conspicuity and confidence in differentiating metastases from haemangiomas. Results were compared using alternative free-response receiver-operating characteristic (AFROC) and conventional ROC methods. Histology and follow-up served as reference standard. There were 145 metastases and 16 haemangiomas. Both readers detected more metastases using combined gadoxetic acid/gadofosveset (reader 1 = 130; reader 2 = 124) compared to gadoxetic acid alone (reader 1 = 104; reader 2 = 103). Sensitivity of combined gadoxetic acid/gadofosveset (reader 1 = 90 %; reader 2 = 86 %) was higher than that of gadoxetic acid alone (reader 1 = 72 %; reader 2 = 71 %, both P < 0.01). AFROC-AUC was higher for the combined technique (0.92 vs. 0.86, P < 0.001). Sensitivity for correct differentiation of metastases from haemangiomas was higher for the combined technique (reader 1 = 98 %; reader 2 = 99 % vs. reader 1 = 86 %; reader 2 = 91 %, both P < 0.01). ROC-AUC was significantly higher for the combined technique (reader 1 = 1.00; reader 2 = 1.00 vs. reader 1 = 0.87; reader 2 = 0.92, both P < 0.01). Combined gadoxetic acid/gadofosveset-enhanced MRI improves detection and characterization of liver metastases compared to gadoxetic acid alone. (orig.)

  17. Radiometric and geometric characteristics of Pleiades images

    Science.gov (United States)

    Jacobsen, K.; Topan, H.; Cam, A.; Özendi, M.; Oruc, M.

    2014-11-01

    Pleiades images are distributed with 50 cm ground sampling distance (GSD) even if the physical resolution for nadir images is just 70 cm. By theory this should influence the effective GSD determined by means of point spread function at image edges. Nevertheless by edge enhancement the effective GSD can be improved, but this should cause enlarged image noise. Again image noise can be reduced by image restoration. Finally even optimized image restoration cannot improve the image information from 70 cm to 50 cm without loss of details, requiring a comparison of Pleiades image details with other very high resolution space images. The image noise has been determined by analysis of the whole images for any sub-area with 5 pixels times 5 pixels. Based on the standard deviation of grey values in the small sub-areas the image noise has been determined by frequency analysis. This leads to realistic results, checked by test targets. On the other hand the visual determination of image noise based on apparently homogenous sub-areas results in too high values because the human eye is not able to identify small grey value differences - it is limited to just approximately 40 grey value steps over the available gray value range, so small difference in grey values cannot be seen, enlarging results of a manual noise determination. A tri-stereo combination of Pleiades 1A in a mountainous, but partially urban, area has been analyzed and compared with images of the same area from WorldView-1, QuickBird and IKONOS. The image restoration of the Pleiades images is very good, so the effective image resolution resulted in a factor 1.0, meaning that the effective resolution corresponds to the nominal resolution of 50 cm. This does not correspond to the physical resolution of 70 cm, but by edge enhancement the steepness of the grey value profile across the edge can be enlarged, reducing the width of the point spread function. Without additional filtering edge enhancement enlarges the image

  18. Enhanced oxidation and detection of toxic ractopamine using carbon nanotube film-modified electrode

    International Nuclear Information System (INIS)

    Liu Zhuan; Zhou Yikai; Wang Yanying; Cheng Qin; Wu Kangbing

    2012-01-01

    Highlights: ► The enhanced oxidation of ractopamine on MWCNT film surface was firstly studied. ► The oxidation occurred at phenolic hydroxyl groups and transferred two electrons. ► A sensitive and effective electrochemical sensor was developed for ractopamine. ► It was used to detect ractopamine in animal tissues, the recovery was satisfactory. - Abstract: Insoluble multi-walled carbon nanotube (MWCNT) was readily dispersed into water in the presence of dihexadecyl hydrogen phosphate, and then used to modify the surface of glassy carbon electrode (GCE) by means of solvent evaporation. Scanning electron microscopy test indicated that the GCE surface was coated with uniform MWCNT film. The resulting MWCNT film-modified GCE greatly enhanced the oxidation signal of ractopamine. The oxidation mechanism was studied, and it was found that the oxidation of ractopamine occurred at two phenolic hydroxyl groups, involving two protons and two electrons. Moreover, the influences of pH value, amount of MWCNT, accumulation potential and time were investigated on the oxidation signal of ractopamine. Based on the strong enhancement effect of MWCNT, a sensitive, rapid and simple electrochemical method was developed for the detection of ractopamine. The linear range was from 50 μg L −1 to 2 mg L −1 , and the detection limit was 20 μg L −1 . Finally, this method was successfully used to detect the content of ractopamine in pork and liver samples, and the recovery was in the range from 93.1% to 107.2%.

  19. Geometric Calibration and Radiometric Correction of the Maia Multispectral Camera

    Science.gov (United States)

    Nocerino, E.; Dubbini, M.; Menna, F.; Remondino, F.; Gattelli, M.; Covi, D.

    2017-10-01

    Multispectral imaging is a widely used remote sensing technique, whose applications range from agriculture to environmental monitoring, from food quality check to cultural heritage diagnostic. A variety of multispectral imaging sensors are available on the market, many of them designed to be mounted on different platform, especially small drones. This work focuses on the geometric and radiometric characterization of a brand-new, lightweight, low-cost multispectral camera, called MAIA. The MAIA camera is equipped with nine sensors, allowing for the acquisition of images in the visible and near infrared parts of the electromagnetic spectrum. Two versions are available, characterised by different set of band-pass filters, inspired by the sensors mounted on the WorlView-2 and Sentinel2 satellites, respectively. The camera details and the developed procedures for the geometric calibrations and radiometric correction are presented in the paper.

  20. Radiometric analyzer with plural radiation sources and detectors

    International Nuclear Information System (INIS)

    Arima, S.; Oda, M.; Miyashita, K.; Takada, M.

    1977-01-01

    A radiometric analyzer for measuring characteristics of a material by radiation comprises a plurality of systems in which each consists of a radiation source and a radiation detector which are the same in number as the number of elements of the molecule of the material and a linear calibration circuit having inverse response characteristics (calibration curve) of the respective systems of detectors, whereby the measurement is carried out by four fundamental rules by operation of the mutual outputs of said detector system obtained through said linear calibration circuit. One typical embodiment is a radiometric analyzer for hydrocarbons which measures the density of heavy oil, the sulfur content and the calorific value by three detector systems which include a γ-ray source (E/sub γ/ greater than 50 keV), a soft x-ray source (Ex approximately 20 keV), and a neutron ray source. 2 claims, 6 figures

  1. High speed radiometric measurements of IED detonation fireballs

    Science.gov (United States)

    Spidell, Matthew T.; Gordon, J. Motos; Pitz, Jeremey; Gross, Kevin C.; Perram, Glen P.

    2010-04-01

    Continuum emission is predominant in fireball spectral phenomena and in some demonstrated cases, fine detail in the temporal evolution of infrared spectral emissions can be used to estimate size and chemical composition of the device. Recent work indicates that a few narrow radiometric bands may reveal forensic information needed for the explosive discrimination and classification problem, representing an essential step in moving from "laboratory" measurements to a rugged, fieldable system. To explore phenomena not observable in previous experiments, a high speed (10μs resolution) radiometer with four channels spanning the infrared spectrum observed the detonation of nine home made explosive (HME) devices in the 0.98) using blast model functional forms, suggesting that energy release could be estimated from single-pixel radiometric detectors. Comparison of radiometer-derived fireball size with FLIR infrared imagery indicate the Planckian intensity size estimates are about a factor of two smaller than the physical extent of the fireball.

  2. Study of a new radiometric sterility test in radiopharmaceuticals

    International Nuclear Information System (INIS)

    Sanchez P, A.R.

    1976-01-01

    A new radiometric method is studied for the determination of sterility. It is based on a culture marked with carbon-14 and the measurement by liquid scintillation of the radioactivity of the gaseous products released after a short period of incubation. The studied samples consisted in nonradioactive solutions and different radiopharmaceuticals, through a regulated current of nitrogen there is a transportation of gaseous and volatile products produced in each flask, which were received in a liquid scintillation vial. The experimental data permit to conclude that through the radiometric method the results can be obtained after 24 hours or less of incubation, instead of a period of several days which was necessary with the traditional process. Due to the sensitivity of the method it is possible to inoculate a minimum volume of sample, this is important in the case of the preparation of little parts for injection as it occurs generally with the pharmaceuticals. (author)

  3. Radiometric microbiologic assay for the biologically active forms of niacin

    Energy Technology Data Exchange (ETDEWEB)

    Kertcher, J.A.; Guilarte, T.R.; Chen, M.F.; Rider, A.A.; McIntyre, P.A.

    1979-05-01

    A radiometric microbiologic assay has been developed for the determination of niacin in biologic fluids. Lactobacillus plantarum produced /sup 14/CO/sub 2/ from L-(U-/sup 14/C) malic acid in quantities proportional to the amount of niacin present. The assay is specific for the biologically active forms of niacin in humans. Thirty normal hemolysates were analyzed and the values ranged from 13.0 to 17.8 ..mu..g niacin/ml RBC (mean = 15.27 +- 1.33 s.d.). Good recovery and reproducibility studies were obtained with this assay. On thirty blood samples, correlation was excellent between the radiometric and the conventional turbidimetric assays.

  4. Rapid detection of acetamiprid in foods using surface-enhanced Raman spectroscopy (SERS).

    Science.gov (United States)

    Wijaya, Wisiani; Pang, Shintaro; Labuza, Theodore P; He, Lili

    2014-04-01

    Acetamiprid is a neonicotinoid pesticide that is commonly used in modern farming. Acetamiprid residue in food commodities can be a potential harm to human and has been implicated in the honey bee hive die off crisis. In this study, we developed rapid, simple, and sensitive methods to detect acetamiprid in apple juice and on apple surfaces using surface-enhanced Raman spectroscopy (SERS). No pretreatment of apple juice sample was performed. A simple surface swab method was used to recover acetamiprid from the apple surface. Samples were incubated with silver dendrites for several minutes and SERS spectra were taken directly from the silver surface. Detection of a set of 5 apple juice samples can be done within 10 min. The swab-SERS method took 15 min for a set of 5 samples. Resulting spectral data were analyzed using principal component analysis. The highest acetamiprid peak at 634 cm(-1) was used to detect and quantify the amount of acetamiprid spiked in 1:1 water-methanol solvent, apple juice, and on apple surface. The SERS method was able to successfully detect acetamiprid at 0.5 μg/mL (0.5 ppm) in solvent, 3 μg/mL (3 ppm) in apple juice, and 0.125 μg/cm(2) on apple surfaces. The SERS methods provide simple, rapid, and sensitive ways to detect acetamiprid in beverages and on the surfaces of thick skinned fruits and vegetables. © 2014 Institute of Food Technologists®

  5. Hypervascular hepatocellular carcinomas: detection with gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Hiromitsu; Kim, Tonsok; Hori, Masatoshi; Nakaya, Yasuhiro; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tatsumi, Mitsuaki; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan); Imai, Yasuharu [Ikeda Municipal Hospital, Department of Gastroenterology, Ikeda, Osaka (Japan); Nagano, Hiroaki [Osaka University Graduate School of Medicine, Department of Surgery, Suita, Osaka (Japan); Kumano, Seishi; Okada, Masahiro; Murakami, Takamichi [Kinki University School of Medicine, Department of Radiology, Osakasayama, Osaka (Japan); Takamura, Manabu [Ikeda Municipal Hospital, Department of Radiology, Ikeda, Osaka (Japan); Wakasa, Kenichi [Osaka City University Graduate School of Medicine, Department of Diagnostic Pathology, Osaka, Osaka (Japan)

    2012-04-15

    To retrospectively compare the accuracy of detection of hypervascular hepatocellular carcinoma (HCC) by multiphasic multidetector CT and by gadoxetate disodium-enhanced MR imaging. After ethical approval, we analysed a total of 73 hypervascular HCC lesions from 31 patients suspected of having HCC, who underwent both gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Five blinded observers independently reviewed CT images, as well as dynamic MR images alone and combined with hepatobiliary phase MR images. Diagnostic accuracy (Az values), sensitivities and positive predictive values were compared by using the Scheffe post hoc test. The mean Az value for dynamic and hepatobiliary phase MR combined (0.81) or dynamic MR images alone (0.78) was significantly higher than that for CT images (0.67, P < 0.001, 0.005, respectively). The mean sensitivity of the combined MR images (0.67) was significantly higher than that of dynamic MR alone (0.52, P < 0.05) or CT images (0.44, P < 0.05). The mean positive predictive values were 0.96, 0.95 and 0.94, for CT, dynamic MR alone and combined MR images, respectively. Compared with multiphasic multidetector CT, gadoxetate disodium-enhanced MR imaging combining dynamic and hepatobiliary phase images results in significantly improved sensitivity and diagnostic accuracy for detection of hypervascular HCC. (orig.)

  6. Modeling the heterogeneous traffic correlations in urban road systems using traffic-enhanced community detection approach

    Science.gov (United States)

    Lu, Feng; Liu, Kang; Duan, Yingying; Cheng, Shifen; Du, Fei

    2018-07-01

    A better characterization of the traffic influence among urban roads is crucial for traffic control and traffic forecasting. The existence of spatial heterogeneity imposes great influence on modeling the extent and degree of road traffic correlation, which is usually neglected by the traditional distance based method. In this paper, we propose a traffic-enhanced community detection approach to spatially reveal the traffic correlation in city road networks. First, the road network is modeled as a traffic-enhanced dual graph with the closeness between two road segments determined not only by their topological connection, but also by the traffic correlation between them. Then a flow-based community detection algorithm called Infomap is utilized to identify the road segment clusters. Evaluated by Moran's I, Calinski-Harabaz Index and the traffic interpolation application, we find that compared to the distance based method and the community based method, our proposed traffic-enhanced community based method behaves better in capturing the extent of traffic relevance as both the topological structure of the road network and the traffic correlations among urban roads are considered. It can be used in more traffic-related applications, such as traffic forecasting, traffic control and guidance.

  7. Uncertainty Evaluations of the CRCS In-orbit Field Radiometric Calibration Methods for Thermal Infrared Channels of FENGYUN Meteorological Satellites

    Science.gov (United States)

    Zhang, Y.; Rong, Z.; Min, M.; Hao, X.; Yang, H.

    2017-12-01

    Meteorological satellites have become an irreplaceable weather and ocean-observing tool in China. These satellites are used to monitor natural disasters and improve the efficiency of many sectors of Chinese national economy. It is impossible to ignore the space-derived data in the fields of meteorology, hydrology, and agriculture, as well as disaster monitoring in China, a large agricultural country. For this reason, China is making a sustained effort to build and enhance its meteorological observing system and application system. The first Chinese polar-orbiting weather satellite was launched in 1988. Since then China has launched 14 meteorological satellites, 7 of which are sun synchronous and 7 of which are geostationary satellites; China will continue its two types of meteorological satellite programs. In order to achieve the in-orbit absolute radiometric calibration of the operational meteorological satellites' thermal infrared channels, China radiometric calibration sites (CRCS) established a set of in-orbit field absolute radiometric calibration methods (FCM) for thermal infrared channels (TIR) and the uncertainty of this method was evaluated and analyzed based on TERRA/AQUA MODIS observations. Comparisons between the MODIS at pupil brightness temperatures (BTs) and the simulated BTs at the top of atmosphere using radiative transfer model (RTM) based on field measurements showed that the accuracy of the current in-orbit field absolute radiometric calibration methods was better than 1.00K (@300K, K=1) in thermal infrared channels. Therefore, the current CRCS field calibration method for TIR channels applied to Chinese metrological satellites was with favorable calibration accuracy: for 10.5-11.5µm channel was better than 0.75K (@300K, K=1) and for 11.5-12.5µm channel was better than 0.85K (@300K, K=1).

  8. Processing data collected from radiometric experiments by multivariate technique

    International Nuclear Information System (INIS)

    Urbanski, P.; Kowalska, E.; Machaj, B.; Jakowiuk, A.

    2005-01-01

    Multivariate techniques applied for processing data collected from radiometric experiments can provide more efficient extraction of the information contained in the spectra. Several techniques are considered: (i) multivariate calibration using Partial Least Square Regression and Artificial Neural Network, (ii) standardization of the spectra, (iii) smoothing of collected spectra were autocorrelation function and bootstrap were used for the assessment of the processed data, (iv) image processing using Principal Component Analysis. Application of these techniques is illustrated on examples of some industrial applications. (author)

  9. An enhanced structure tensor method for sea ice ridge detection from GF-3 SAR imagery

    Science.gov (United States)

    Zhu, T.; Li, F.; Zhang, Y.; Zhang, S.; Spreen, G.; Dierking, W.; Heygster, G.

    2017-12-01

    In SAR imagery, ridges or leads are shown as the curvilinear features. The proposed ridge detection method is facilitated by their curvilinear shapes. The bright curvilinear features are recognized as the ridges while the dark curvilinear features are classified as the leads. In dual-polarization HH or HV channel of C-band SAR imagery, the bright curvilinear feature may be false alarm because the frost flowers of young leads may show as bright pixels associated with changes in the surface salinity under calm surface conditions. Wind roughened leads also trigger the backscatter increasing that can be misclassified as ridges [1]. Thus the width limitation is considered in this proposed structure tensor method [2], since only shape feature based method is not enough for detecting ridges. The ridge detection algorithm is based on the hypothesis that the bright pixels are ridges with curvilinear shapes and the ridge width is less 30 meters. Benefited from GF-3 with high spatial resolution of 3 meters, we provide an enhanced structure tensor method for detecting the significant ridge. The preprocessing procedures including the calibration and incidence angle normalization are also investigated. The bright pixels will have strong response to the bandpass filtering. The ridge training samples are delineated from the SAR imagery in the Log-Gabor filters to construct structure tensor. From the tensor, the dominant orientation of the pixel representing the ridge is determined by the dominant eigenvector. For the post-processing of structure tensor, the elongated kernel is desired to enhance the ridge curvilinear shape. Since ridge presents along a certain direction, the ratio of the dominant eigenvector will be used to measure the intensity of local anisotropy. The convolution filter has been utilized in the constructed structure tensor is used to model spatial contextual information. Ridge detection results from GF-3 show the proposed method performs better compared to the

  10. A radiometric microassay for glutamic acid decarboxylase

    International Nuclear Information System (INIS)

    Maderdrut, J.L.; North Carolina Univ., Chapel Hill

    1979-01-01

    A simple method for purifying L-[ 3 H] glutamic acid and incubation conditions suitable for estimating L-glutamic acid decarboxylase activity are described. Routine and recycled cation-exchange procedure for separating γ-aminobutyric acid from L-glutamate are outlined and compared. Recycling increases the sensitivity of the cation-exchange method by 6-7 fold. L-Glutamate decarboxylase activity can be measured reliably in samples of embryonic neural tissue having wet-weights of approximately 1 μg. The cation-exchange method is compared with the anion-exchange and CO 2 -trapping methods. L-Glutamate decarboxylase activity has been detected in the lumbar spinal cord of the chick embryo at Day 21/4 (stage 14) using the cation-exchange method. This is 5-6 days earlier than L-glutamate decarboxylase activity has been detected in embryonic neural tissue by previous investigators. L-Glutamate decarboxylase is present in the lumbar spinal cord at least as early as the birth of the first lumbar spinal cord neurons and at least 1-2 days before the initiation of synaptogenesis. (author)

  11. Radiometric microassay for glutamic acid decarboxylase

    Energy Technology Data Exchange (ETDEWEB)

    Maderdrut, J L [North Carolina Dept. of Mental Health, Raleigh (USA); North Carolina Univ., Chapel Hill (USA). School of Medicine)

    1979-01-01

    A simple method for purifying L-(/sup 3/H) glutamic acid and incubation conditions suitable for estimating L-glutamic acid decarboxylase activity are described. Routine and recycled cation-exchange procedure for separating ..gamma..-aminobutyric acid from L-glutamate are outlined and compared. Recycling increases the sensitivity of the cation-exchange method by 6-7 fold. L-Glutamate decarboxylase activity can be measured reliably in samples of embryonic neural tissue having wet-weights of approximately 1 ..mu..g. The cation-exchange method is compared with the anion-exchange and CO/sub 2/-trapping methods. L-Glutamate decarboxylase activity has been detected in the lumbar spinal cord of the chick embryo at Day 21/4 (stage 14) using the cation-exchange method. This is 5-6 days earlier than L-glutamate decarboxylase activity has been detected in embryonic neural tissue by previous investigators. L-Glutamate decarboxylase is present in the lumbar spinal cord at least as early as the birth of the first lumbar spinal cord neurons and at least 1-2 days before the initiation of synaptogenesis.

  12. Archaeological Feature Detection from Archive Aerial Photography with a Sfm-Mvs and Image Enhancement Pipeline

    Science.gov (United States)

    Peppa, M. V.; Mills, J. P.; Fieber, K. D.; Haynes, I.; Turner, S.; Turner, A.; Douglas, M.; Bryan, P. G.

    2018-05-01

    Understanding and protecting cultural heritage involves the detection and long-term documentation of archaeological remains alongside the spatio-temporal analysis of their landscape evolution. Archive aerial photography can illuminate traces of ancient features which typically appear with different brightness values from their surrounding environment, but are not always well defined. This research investigates the implementation of the Structure-from-Motion - Multi-View Stereo image matching approach with an image enhancement algorithm to derive three epochs of orthomosaics and digital surface models from visible and near infrared historic aerial photography. The enhancement algorithm uses decorrelation stretching to improve the contrast of the orthomosaics so as archaeological features are better detected. Results include 2D / 3D locations of detected archaeological traces stored into a geodatabase for further archaeological interpretation and correlation with benchmark observations. The study also discusses the merits and difficulties of the process involved. This research is based on a European-wide project, entitled "Cultural Heritage Through Time", and the case study research was carried out as a component of the project in the UK.

  13. Effect of background parenchymal enhancement on breast cancer detection with magnetic resonance imaging.

    Science.gov (United States)

    Telegrafo, M; Rella, L; Stabile Ianora, A A; Angelelli, G; Moschetta, M

    2016-03-01

    To investigate whether background parenchymal enhancement (BPE) may influence the sensitivity of dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging in breast cancer detection. A total of 180 consecutive women with 194 breast cancers underwent MR imaging examination. Women were assigned to two different groups depending on the degree of BPE. Group 1 consisted of women with minimal or mild BPE and group 2 of women with moderate or marked BPE. The distributions of histotypes of tumors within the two groups were compared using the χ(2) test. Difference in sensitivities of DCE-MR imaging for tumor detection between the two groups was searched for using the Student t-test. No differences in terms of distributions of histotypes of tumors between the two groups of women were found (P=0.5). The 11% difference in sensitivity of DCE-MR imaging for tumor detection between group 1 (91/92; 99%; 95% CI: 94-100%) and group 2 (90/102; 88%; 95% CI: 80-94%) was statistically significant (P=0.0058). The sensitivity of DCE-MR imaging is significantly lower in women with moderate and marked BPE as compared with women with minimal and mild BPE regardless of cancer histotype. BPE could represent a limitation for breast MR imaging interpretation and should be indicated in MR imaging reports. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  14. THE EFFECT OF IMAGE ENHANCEMENT METHODS DURING FEATURE DETECTION AND MATCHING OF THERMAL IMAGES

    Directory of Open Access Journals (Sweden)

    O. Akcay

    2017-05-01

    Full Text Available A successful image matching is essential to provide an automatic photogrammetric process accurately. Feature detection, extraction and matching algorithms have performed on the high resolution images perfectly. However, images of cameras, which are equipped with low-resolution thermal sensors are problematic with the current algorithms. In this paper, some digital image processing techniques were applied to the low-resolution images taken with Optris PI 450 382 x 288 pixel optical resolution lightweight thermal camera to increase extraction and matching performance. Image enhancement methods that adjust low quality digital thermal images, were used to produce more suitable images for detection and extraction. Three main digital image process techniques: histogram equalization, high pass and low pass filters were considered to increase the signal-to-noise ratio, sharpen image, remove noise, respectively. Later on, the pre-processed images were evaluated using current image detection and feature extraction methods Maximally Stable Extremal Regions (MSER and Speeded Up Robust Features (SURF algorithms. Obtained results showed that some enhancement methods increased number of extracted features and decreased blunder errors during image matching. Consequently, the effects of different pre-process techniques were compared in the paper.

  15. Enhancement of crack detection in stud bolts of nuclear reactor by ultrasonic technique

    International Nuclear Information System (INIS)

    Lee, Joon-Hyun; Choi, Sang-Woo; Oh, Won-Deok

    2004-01-01

    The stud bolt is one of crucial parts for safety of reactor vessels in nuclear power plants. Crack initiation and propagation were reported in stud bolts using closure of reactor vessel and head. Stud bolts are inspected by ultrasonic technique during overhaul periodically for the prevention of stud bolt failure and radioactive leakage from nuclear reactor. In conventional ultrasonic testing for inspection of stud bolts, crack was detected by using shadow effect. It takes too much time to inspect stud bolt by using conventional ultrasonic technique. In addition, there were numerous spurious signals reflected from every oblique surfaces of thread. In this study, the signal processing technique for enhancing conventional ultrasonic technique and the advanced ultrasonic phased array technique were introduced for inspect stud bolts. The signal processing technique provides removing spurious signal reflected from every oblique surfaces of thread and enhances detectability of defects. The phased array technique provides fast inspection and can be applied for structure of complex shape. There are sector scanning and linear scanning methods in phased array technique, and these scanning methods were applied to inspect stud bolt and detectability was investigated. (author)

  16. Ag/SiO2 surface-enhanced Raman scattering substrate for plasticizer detection

    Science.gov (United States)

    Wu, Ming-Chung; Lin, Ming-Pin; Lin, Ting-Han; Su, Wei-Fang

    2018-04-01

    In this study, we demonstrated a simple method of fabricating a high-performance surface-enhanced Raman scattering (SERS) substrate. Monodispersive SiO2 colloidal spheres were self-assembled on a silicon wafer, and then a silver layer was coated on it to obtain a Ag/SiO2 SERS substrate. The Ag/SiO2 SERS substrates were used to detect three kinds of plasticizer with different concentrations, namely, including bis(2-ethylhexyl)phthalate (DEHP), benzyl butyl phthalate (BBP), and dibutyl phthalate (DBP). The enhancement of Raman scattering intensity caused by surface plasmon resonance can be observed using the Ag/SiO2 SERS substrates. The Ag/SiO2 SERS substrate with a 150-nm-thick silver layer can detect plasticizers, and it satisfies the detection limit of plasticizers at 100 ppm. The developed highly sensitive Ag/SiO2 SERS substrates show a potential for the design and fabrication of functional sensors to identify the harmful plasticizers that plastic products release in daily life.

  17. A Preliminary Analysis of LANDSAT-4 Thematic Mapper Radiometric Performance

    Science.gov (United States)

    Justice, C.; Fusco, L.; Mehl, W.

    1985-01-01

    The NASA raw (BT) product, the radiometrically corrected (AT) product, and the radiometrically and geometrically corrected (PT) product of a TM scene were analyzed examine the frequency distribution of the digital data; the statistical correlation between the bands; and the variability between the detectors within a band. The analyses were performed on a series of image subsets from the full scence. Results are presented from one 1024 c 1024 pixel subset of Realfoot Lake, Tennessee which displayed a representative range of ground conditions and cover types occurring within the full frame image. From this cursory examination of one of the first seven channel TM data sets, it would appear that the radiometric performance of the system is most satisfactory and largely meets pre-launch specifications. Problems were noted with Band 5 Detector 3 and Band 2 Detector 4. Differences were observed between forward and reverse scan detector responses both for the BT and AT products. No systematic variations were observed between odd and even detectors.

  18. Multielemental X-ray radiometric analysis of ferromanganese concretions

    International Nuclear Information System (INIS)

    Metelev, A.Yu.; Grigor'ev, A.I.; Rakita, K.A.; Mamaenko, M.V.; Ivanenko, V.V.

    1994-01-01

    Ferromanganese concretions are promising mineral resources of the ocean. Most often, they are analyzed by atomic-absorption, spectra, X-ray spectral, neutron-activation, and X-ray radiometric methods. Note that X-ray radiometric analysis (XRRA) allows the sufficiently rapid determination of a great number of elements in ferromanganese concretions. The possibility of using XRRA with saturated and thin layers was shown; however, the data on the precision and accuracy of the technique was not given. The purpose of this study is to evaluate the basic performance characteristics of the multielemental X-ray radiometric analysis of ferromanganese concretions (Pacific Ocean). Determinations for K,Ca and Ti content were made using a 55 Fe source and for Mn, Fe, Ni, Cu, Zn, Pb, Sr, Y, Zr, Nb, and Mo contents by using a 109 Cd source. The precision and accuracy of the method was investigated by using reference concretions; it was found the confidence intervals overlap for all of the elements except Ca and Pb. The relative standard deviation was 1-5%, indicating the high precision of the method. The described technique is successfully used on research vessels of the Far East Division of the Russian Academy of Sciences and in South Pacific Ocean geological expeditions of PO open-quotes Dal'morgeologiyaclose quotes

  19. Laboratory-Based BRDF Calibration of Radiometric Tarps

    Science.gov (United States)

    Georgiev, Georgi T.; Butler, James J.

    2007-01-01

    The current study provides the remote sensing community with important high accuracy laboratory-based BRDF calibration of radiometric tarps. The results illustrate the dependence of tarps' weft and warp threads orientation on BRDF. The study was done at incident angles of 0deg, 10deg, and 30deg; scatter zenith angles from 0deg to 60deg, and scatter azimuth angles of 0deg, 45deg, 90deg, 135deg, and 180deg. The wavelengths were 485nm, 550nm, 633nm and 800nm. The dependence is well defined at all measurement geometries and wavelengths. It can be as high as 8% at 0deg incident angle and 2% at 30deg incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps is reported. The backward scatter is well pronounced for the white samples. The black sample has well pronounced forward scatter. The BRDF characterization of radiometric tarps can be successfully extended to other structured surface fabric samples. The results are NIST traceable.

  20. A simple approach for ultrasensitive detection of bisphenols by multiplexed surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    De Bleye, C., E-mail: cdebleye@ulg.ac.be; Dumont, E.; Hubert, C.; Sacré, P.-Y.; Netchacovitch, L.; Chavez, P.-F.; Hubert, Ph.; Ziemons, E.

    2015-08-12

    Bisphenol A (BPA) is well known for its use in plastic manufacture and thermal paper production despite its risk of health toxicity as an endocrine disruptor in humans. Since the publication of new legislation regarding the use of BPA, manufacturers have begun to replace BPA with other phenolic molecules such as bisphenol F (BPF) and bisphenol B (BPB), but there are no guarantees regarding the health safety of these compounds at this time. In this context, a very simple, cheap and fast surface-enhanced Raman scattering (SERS) method was developed for the sensitive detection of these molecules in spiked tap water solutions. Silver nanoparticles were used as SERS substrates. An original strategy was employed to circumvent the issue of the affinity of bisphenols for metallic surfaces and the silver nanoparticles surface was functionalized using pyridine in order to improve again the sensitivity of the detection. Semi-quantitative detections were performed in tap water solutions at a concentrations range from 0.25 to 20 μg L{sup −1} for BPA and BPB and from 5 to 100 μg L{sup −1} for BPF. Moreover, a feasibility study for performing a multiplex-SERS detection of these molecules was also performed before successfully implementing the developed SERS method on real samples. - Highlights: • Development of a simple, fast and ultrasensitive SERS method to detect bisphenols. • Multiplexed-SERS detection of bisphenol A, bisphenol B and bisphenol F. • Implementation of the SERS developed method on real samples to detect bisphenols.

  1. A simple approach for ultrasensitive detection of bisphenols by multiplexed surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    De Bleye, C.; Dumont, E.; Hubert, C.; Sacré, P.-Y.; Netchacovitch, L.; Chavez, P.-F.; Hubert, Ph.; Ziemons, E.

    2015-01-01

    Bisphenol A (BPA) is well known for its use in plastic manufacture and thermal paper production despite its risk of health toxicity as an endocrine disruptor in humans. Since the publication of new legislation regarding the use of BPA, manufacturers have begun to replace BPA with other phenolic molecules such as bisphenol F (BPF) and bisphenol B (BPB), but there are no guarantees regarding the health safety of these compounds at this time. In this context, a very simple, cheap and fast surface-enhanced Raman scattering (SERS) method was developed for the sensitive detection of these molecules in spiked tap water solutions. Silver nanoparticles were used as SERS substrates. An original strategy was employed to circumvent the issue of the affinity of bisphenols for metallic surfaces and the silver nanoparticles surface was functionalized using pyridine in order to improve again the sensitivity of the detection. Semi-quantitative detections were performed in tap water solutions at a concentrations range from 0.25 to 20 μg L −1 for BPA and BPB and from 5 to 100 μg L −1 for BPF. Moreover, a feasibility study for performing a multiplex-SERS detection of these molecules was also performed before successfully implementing the developed SERS method on real samples. - Highlights: • Development of a simple, fast and ultrasensitive SERS method to detect bisphenols. • Multiplexed-SERS detection of bisphenol A, bisphenol B and bisphenol F. • Implementation of the SERS developed method on real samples to detect bisphenols

  2. The value and limitations of contrast-enhanced transrectal ultrasonography for the detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Han-Xue, E-mail: zhaohx861@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Xia, Chun-Xia, E-mail: star9901482@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Yin, Hong-Xia, E-mail: hongxia_yin79@yahoo.com.cn [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Guo, Ning, E-mail: ningguo99@sina.com.cn [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Zhu, Qiang, E-mail: qzhutrhos@gmail.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China)

    2013-11-01

    Objectives: To evaluate the role of contrast-enhanced transrectal ultrasonography (CE-TRUS) for detecting prostate carcinoma. Methods: Sixty-five patients with elevated serum prostate-specific antigen (PSA) and/or abnormal digital rectal examination (DRE) were assessed using transrectal ultrasound (TRUS) and CE-TRUS. In all the patients, CE-TRUS was performed with intravenous injection of contrast agent (SonoVue, 2.4 ml) before biopsy. The cancer detection rates of the two techniques were compared. False-positive and false-negative findings related to CE-TRUS were analyzed in comparison to the pathological results of biopsy or radical prostatectomy. The targeted biopsy to abnormal CE-TRUS areas was also compared to systematic biopsy. Results: Prostate cancer was detected in 29 of the 65 patients. CE-TRUS showed rapid focal enhancement or asymmetric vessels of peripheral zones in 28 patients; 23 of them had prostate cancer. CE-TRUS had 79.3% sensitivity, compared to 65.5% of TRUS (P < 0.05). There were five false-positive and six false-negative findings from CE-TRUS. Benign prostate hyperplasia, and acute and chronic prostatitis were important causes related to the false-positive results of CE-TRUS. Prostate cancer originating from the transition zone or peripheral zone with lower PSA levels, small-size foci, and moderately or well-differentiated tumor was missed by CE-TRUS. The cancer detection rate of targeted biopsy (75%, 33/44 cores) was significantly higher than one of systematic biopsy (48.2%, 162/336) in those 28 cases (P < 0.05). In addition, no significant correlation was found between the cancer detection rate with CE-TRUS and serum PSA levels. Conclusion: CE-TRUS may improve the detection rate of prostate cancer through targeted biopsy of contrast-enhanced abnormalities. Our findings indicate that systematic biopsies should not be eliminated on the basis of false-positive and false-negative findings related to CE-TRUS.

  3. A study of elemental migration from poly(ethylene terephthalate) of food packagings to simulated solutions by radiometric method

    International Nuclear Information System (INIS)

    Soares, Eufemia Paez; Saki, Mitiko; Silva, Leonardo G.A.

    2007-01-01

    Brazilian plastic production for food packagings, in recent years, has grown in the same proportion as food consumption. Considering that the plastic manufacturing involves catalytic processes and the use of additives, when the foods are in direct contact with these materials, the components present in plastics may migrate to the food. The Brazilian Health Surveillance Agency (ANVISA) has established boundary-values of migrants as well as procedures to evaluate migration of elements and substances from plastic packaging to food. In this study elemental composition of poly (ethylene terephthalate) - PET - packaging and results of elemental migration were obtained. Instrumental Neutron Activation Analysis (INAA) was used to determine elemental concentrations in PET packagings and the radiometric method was applied for elemental migration determination. This radiometric method consisted of irradiating the PET samples with neutrons, followed by migration exposition and radioactivity measurement in food-simulated solution. Experimental conditions used for migration were 10 days exposure period at 40 deg C. Migration was evaluated for soft drink, juice and water PET packaging. The analytical results indicated that PET packagings contain Co and Sb and those elements are transferred to the simulated solutions. However, these migration results were lower than the maximum tolerance values established by ANVISA. The migration detection limits also indicated high sensitivity of the radiometric method. (author)

  4. Report on the feasibility of the in situ radiometric determination of uranium grade in Witwatersrand gold and uranium mines

    International Nuclear Information System (INIS)

    Smit, C.J.B.; Wesolinski, E.S.; Corner, B.

    1982-08-01

    The chip-sampling technique currently employed by the South African gold and uranium-mining industry, for the prediction of face grade, has several drawbacks, namely: 1) it is labour-intensive; 2) sample volumes are often unrepresentative and prone to human error; and 3) the uranium mineralisation may be very erratic along the reef. In situ radiometric assaying for uranium along the reef, on the other hand, is a rapid, essentially one-man operation, enabling a much larger and hence a more representative sample volume to be measured. The high radiometric background inherent in any uranium mine necessitates some form of high-density shielding in order to facilitate quantitative in situ assaying. This report, therefore, briefly outlines the origin, nature, detection and shielding of gamma rays. Results obtained with a frontally shielded total-count instrument showed that radiometric estimates of uranium grade are comparable to those obtained by batch mining and can be used for the prediction of face grades, provided that the ore is in radiometric equilibrium and that thorium and potassium are either not present, or vary sympathetically with the uranium grade. Spectral analysis showed, however, that these circumstances will also permit the use of a collimated (side-shielded) detector of acceptable weight, provided that only the low-energy portion of the spectrum is measured. The advantages of a collimated detector over a frontally shielded detector are also noteworthy, viz.: 1) only one reading is taken per sample point rather than two, as is the case with the frontally shielded system, thus improving counting statistics; and 2) the shielding is permanently fixed to the detector. Comprehensive design considerations for a compact, portable instrument are suggested and methods for determining background radiation as applicable to a collimated detector are described

  5. Radiometric measurement of ceramic material moisture

    International Nuclear Information System (INIS)

    Kominek, A.; Sojka, J.; Votava, P.

    1975-01-01

    Water content measurement using a neutron moisture meter has a long tradition in the CSSR. The method of water content determination using neutron and gamma radiation was developed by the Research Institute of Building Materials in Brno for a number of materials, as e.g. coke, brown coal semi-coke, anthracite, glass sand, dolomite, soda, gravel, aggregates, cement sludge, slag, brick clay, intermediate products of the ceramics industry, refractory building materials, etc. The water content measurement of ceramic materials for the manufacture of wall tiles was performed in a special equipment by detection of the slowed-down neutrons with an accuracy of +-0.6% water (within the range from 5 to 11%) and of materials for the manufacture of floor tiles by means of neutron and gamma radiation with an accuracy of +-0.4% water (within the range from 5 to 8%). (author)

  6. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Radiometric assays for the measurement of PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.

    1997-01-01

    Prostate Specific Antigen, a serine protease enzyme, of M.W. ∼ 26-33 kDa, is widely considered to be a very useful marker for prostate cancer. It satisfies nearly all the requirements of an ideal 'Tumour Marker' and has hence attracted a lot of attention in the past decade. PSA is present in multiple forms in serum, with an appreciable fraction bound to the protease inhibitor α-1-antichymotrypsin (ACT) and to a small extent to other proteins such as α-2-macroglobulin (AMG) leaving the rest in the free form. The total PSA levels have been reported to have 80% sensitivity and 60% specificity towards the detection of prostate cancer. The lack of specificity occurs mainly due to the high levels of t-PSA in benign prostatic hypertrophy(BPH) apart from the cancer. The concept of free PSA has been introduced in the recent past and the ratio of free/total PSA levels have been shown to be advantageous in the differential diagnosis of BPH from prostate cancer. The f/t ratio is considered to be particularly useful in the grey zones of decision making (t-PSA levels 4-20 ng/mL). The need for the development of assays for total and free PSA is felt due to: a. the high incidence of prostate cancers being detected currently; b. the high cost of tests (higher for free PSA assay, and the cost becomes an important parameter when a patient has to be regularly monitored after therapy) that is not affordable for many patients; c. the potential for research in the area of prostate cancer management where the PSA (total and free) assays will be of great help

  8. Enhancing early bladder cancer detection with fluorescence-guided endoscopic optical coherence tomography

    Science.gov (United States)

    Pan, Y. T.; Xie, T. Q.; Du, C. W.; Bastacky, S.; Meyers, S.; Zeidel, M. L.

    2003-12-01

    We report an experimental study of the possibility of enhancing early bladder cancer diagnosis with fluorescence-image-guided endoscopic optical coherence tomography (OCT). After the intravesical instillation of a 10% solution of 5-aminolevulinic acid, simultaneous fluorescence imaging (excitation of 380-420 nm, emission of 620-700 nm) and OCT are performed on rat bladders to identify the photochemical and morphological changes associated with uroepithelial tumorigenesis. The preliminary results of our ex vivo study reveal that both fluorescence and OCT can identify early uroepithelial cancers, and OCT can detect precancerous lesions (e.g., hyperplasia) that fluorescence may miss. This suggests that a cystoscope combining 5-aminolevulinic acid fluorescence and OCT imaging has the potential to enhance the efficiency and sensitivity of early bladder cancer diagnosis.

  9. Raman signal enhancement by multiple beam excitation and its application for the detection of chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Sakshi [Laser Science and Technology Centre, Metcalfe House, Delhi 110054 (India); Instrument Design and Development Centre, Indian Institute of Technology, Hauz Khas, New Delhi 110016 (India); Ahmad, Azeem; Mehta, Dalip S., E-mail: mehtads@physics.iitd.ac.in [Department of Physics, Indian Institute of Technology, Hauz Khas, New Delhi 110016 (India); Gambhir, Vijayeta; Reddy, Martha N. [Laser Science and Technology Centre, Metcalfe House, Delhi 110054 (India)

    2015-08-31

    In a typical Raman based sensor, a single laser beam is used for exciting the sample and the backscattered or forward scattered light is collected using collection optics and is analyzed by a spectrometer. We have investigated that by means of exciting the sample with multiple beams, i.e., by dividing the same input power of the single beam into two or three or more beams and exciting the sample from different angles, the Raman signal enhances significantly. Due to the presence of multiple beams passing through the same volume of the sample, an interference pattern is formed and the volume of interaction of excitation beams with the sample increases. By means of this geometry, the enhancement in the Raman signal is observed and it was found that the signal strength increases linearly with the increase in number of excitation beams. Experimental results of this scheme for excitation of the samples are reported for explosive detection at a standoff distance.

  10. Contrast-enhanced swallow study sensitivity for anastomotic leak detection in post-esophagectomy patients.

    Science.gov (United States)

    Mejía-Rivera, S; Pérez-Marroquín, S A; Cortés-González, R; Medina-Franco, H

    2018-03-07

    Esophagectomy is a highly invasive surgery and one of its postoperative complications is anastomotic leakage, occurring in 53% of cases. The aim of the present study was to determine the sensitivity of the contrast-enhanced swallow study as a method for diagnosing anastomotic leak in patients that underwent esophagectomy. The present retrospective study included the case records of patients that underwent esophagectomy with reconstruction and cervical anastomosis at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán within the time frame of January 1, 2000 and May 31, 2006. Demographic, clinical, and laboratory data emphasizing clinical and radiographic anastomotic leak detection were identified. Descriptive statistics were carried out and contrast-enhanced swallow study sensitivity for diagnosing leakage was calculated. Seventy patients were included in the analysis. The mean age of the patients was 50.6 years, 51 of the patients were men (72.86%), and 19 were women (27.14%). Indications for surgery were benign lesion in 29 patients (41.4%) and malignant lesion in 41 (58.6%). A total of 44.3% of the patients presented with a comorbidity, with diabetes mellitus and high blood pressure standing out. Thirty patients (42.85%) presented with anastomotic leak. Contrast-enhanced swallow study sensitivity for leak detection was 43.33%. The diagnostic sensitivity of the contrast-enhanced swallow study was very low. Therefore, we recommend the discontinuation of its routine use as a method for diagnosing anastomotic leaks. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  11. Visible wavelength surface-enhanced Raman spectroscopy from In-InP nanopillars for biomolecule detection

    Science.gov (United States)

    Murdoch, B. J.; Portoles, J. F.; Tardio, S.; Barlow, A. J.; Fletcher, I. W.; Cumpson, P. J.

    2016-12-01

    Visible wavelength surface-enhanced Raman spectroscopy (SERS) has been observed from bovine serum albumin (BSA) using In-InP nanopillars synthesised by Ar gas cluster ion beam sputtering of InP wafers. InP provides a high local refractive index for plasmonic In structures, which increases the wavelength of the In surface plasmon resonance. The Raman scattering signal was determined to be up to 285 times higher for BSA deposited onto In-InP nanopillars when compared with Si wafer substrates. These substrates demonstrate the label-free detection of biomolecules by visible wavelength SERS, without the use of noble metal particles.

  12. Detection of eosinophilic myocarditis using contrast-enhanced magnetic resonance imaging: case report

    International Nuclear Information System (INIS)

    Takahashi, N.; Murakami, Y.; Shimada, T.; Kashima, Y.; Nakamura, K.; Inoue, S.-I.; Sugamori, T.; Katoh, H.; Ishibashi, Y.; Maruyama, R.

    2001-01-01

    Hypereosinophilic syndrome is characterized by idiopathic eosinophilia in the peripheral blood and multiorgan dysfunction secondary to mature eosinophil infiltration. It is essential to diagnose myocardial involvement in the early stage of the disease when active myocarditis due to cardiotoxic substances from eosinophils is still taking place, but clinical tools for the diagnosis of myocardial lesions in patients without overt cardiac dysfunction are not yet available. We present a case of successful detection of myocarditis due to hypereosinophilic syndrome by gadolinium-diethylenetriaminepentaascetic acid (Gd-DTPA) enhanced magnetic resonance imaging (MRI). (author)

  13. Detection of eosinophilic myocarditis using contrast-enhanced magnetic resonance imaging: case report

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, N.; Murakami, Y.; Shimada, T.; Kashima, Y.; Nakamura, K.; Inoue, S.-I.; Sugamori, T.; Katoh, H.; Ishibashi, Y. [Shimane Medical Univ., The Fourth Dept. of Internal Medicine, Izumo City, Shimane (Japan); Maruyama, R. [Shimane Medical Univ., Dept. of Laboratory Medicine, Izumo City, Shimane (Japan)

    2001-02-01

    Hypereosinophilic syndrome is characterized by idiopathic eosinophilia in the peripheral blood and multiorgan dysfunction secondary to mature eosinophil infiltration. It is essential to diagnose myocardial involvement in the early stage of the disease when active myocarditis due to cardiotoxic substances from eosinophils is still taking place, but clinical tools for the diagnosis of myocardial lesions in patients without overt cardiac dysfunction are not yet available. We present a case of successful detection of myocarditis due to hypereosinophilic syndrome by gadolinium-diethylenetriaminepentaascetic acid (Gd-DTPA) enhanced magnetic resonance imaging (MRI). (author)

  14. A Targeted Attack For Enhancing Resiliency of Intelligent Intrusion Detection Modules in Energy Cyber Physical Systems

    Energy Technology Data Exchange (ETDEWEB)

    Youssef, Tarek [Florida Intl Univ., Miami, FL (United States); El Hariri, Mohammad [Florida Intl Univ., Miami, FL (United States); Habib, Hani [Florida Intl Univ., Miami, FL (United States); Mohammed, Osama [Florida Intl Univ., Miami, FL (United States); Harmon, E [Florida Intl Univ., Miami, FL (United States)

    2017-02-28

    Abstract— Secure high-speed communication is required to ensure proper operation of complex power grid systems and prevent malicious tampering activities. In this paper, artificial neural networks with temporal dependency are introduced for false data identification and mitigation for broadcasted IEC 61850 SMV messages. The fast responses of such intelligent modules in intrusion detection make them suitable for time- critical applications, such as protection. However, care must be taken in selecting the appropriate intelligence model and decision criteria. As such, this paper presents a customizable malware script to sniff and manipulate SMV messages and demonstrates the ability of the malware to trigger false positives in the neural network’s response. The malware developed is intended to be as a vaccine to harden the intrusion detection system against data manipulation attacks by enhancing the neural network’s ability to learn and adapt to these attacks.

  15. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    Science.gov (United States)

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Enhancing the mathematical properties of new haplotype homozygosity statistics for the detection of selective sweeps.

    Science.gov (United States)

    Garud, Nandita R; Rosenberg, Noah A

    2015-06-01

    Soft selective sweeps represent an important form of adaptation in which multiple haplotypes bearing adaptive alleles rise to high frequency. Most statistical methods for detecting selective sweeps from genetic polymorphism data, however, have focused on identifying hard selective sweeps in which a favored allele appears on a single haplotypic background; these methods might be underpowered to detect soft sweeps. Among exceptions is the set of haplotype homozygosity statistics introduced for the detection of soft sweeps by Garud et al. (2015). These statistics, examining frequencies of multiple haplotypes in relation to each other, include H12, a statistic designed to identify both hard and soft selective sweeps, and H2/H1, a statistic that conditional on high H12 values seeks to distinguish between hard and soft sweeps. A challenge in the use of H2/H1 is that its range depends on the associated value of H12, so that equal H2/H1 values might provide different levels of support for a soft sweep model at different values of H12. Here, we enhance the H12 and H2/H1 haplotype homozygosity statistics for selective sweep detection by deriving the upper bound on H2/H1 as a function of H12, thereby generating a statistic that normalizes H2/H1 to lie between 0 and 1. Through a reanalysis of resequencing data from inbred lines of Drosophila, we show that the enhanced statistic both strengthens interpretations obtained with the unnormalized statistic and leads to empirical insights that are less readily apparent without the normalization. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. An integrated circuit/microsystem/nano-enhanced four species radiation sensor for inexpensive fissionable material detection

    Science.gov (United States)

    Waguespack, Randy Paul

    2011-12-01

    Small scale radiation detectors sensitive to alpha, beta, electromagnetic, neutron radiation are needed to combat the threat of nuclear terrorism and maintain national security. There are many types of radiation detectors on the market, and the type of detector chosen is usually determined by the type of particle to be detected. In the case of fissionable material, an ideal detector needs to detect all four types of radiation, which is not the focus of many detectors. For fissionable materials, the two main types of radiation that must be detected are gamma rays and neutrons. Our detector uses a glass or quartz scintillator doped with 10B nanoparticles to detect all four types of radiation particles. Boron-10 has a thermal neutron cross section of 3,840 barns. The interaction between the neutron and boron results in a secondary charge particle in the form of an alpha particle to be emitted, which is detectable by the scintillator. Radiation impinging on the scintillator matrix produces varying optical pulses dependent on the energy of the particles. The optical pulses are then detected by a photomultiplier (PM) tube, creating a current proportional to the energy of the particle. Current pulses from the PM tube are differentiated by on-chip pulse height spectroscopy, allowing for source discrimination. The pulse height circuitry has been fabricated with discrete circuits and designed into an integrated circuit package. The ability to replace traditional PM tubes with a smaller, less expensive photomultiplier will further reduce the size of the device and enhance the cost effectiveness and portability of the detector.

  18. Optical resonance-enhanced absorption-based near-field immunochip biosensor for allergen detection.

    Science.gov (United States)

    Maier, Irene; Morgan, Michael R A; Lindner, Wolfgang; Pittner, Fritz

    2008-04-15

    An optical immunochip biosensor has been developed as a rapid method for allergen detection in complex food matrixes, and its application evaluated for the detection of the egg white allergens, ovalbumin and ovomucoid. The optical near-field phenomenon underlying the basic principle of the sensor design is called resonance-enhanced absorption (REA), which utilizes gold nanoparticles (Au NPs) as signal transducers in a highly sensitive interferometric setup. Using this approach, a novel, simple, and rapid colorimetric solid-phase immunoassay on a planar chip substrate was realized in direct and sandwich assay formats, with a detection system that does not require any instrumentation for readout. Semiquantitative immunochemical responses are directly visible to the naked eye of the analyst. The biosensor shows concentration-dependent color development by capturing antibody-functionalized Au NPs on allergen-coated chips and has a detection limit of 1 ng/mL. To establish a rapid method, we took advantage of the physicochemical microenvironment of the Au NP-antibody bioconjugate to be bound directly over an interacting poly(styrene-methyl methacrylate) interlayer by an immobilized antigen. In the direct assay format, a coating time with allergen of only 5 min under "soft" nondenaturing conditions was sufficient for accurate reproducibility and sensitivity. In conclusion, the REA-based immunochip sensor is easy to fabricate, is reproducible and selective in its performance, has minimal technical requirements, and will enable high-throughput screening of affinity binding interactions in technological and medical applications.

  19. Research on fiber-optic cantilever-enhanced photoacoustic spectroscopy for trace gas detection

    Science.gov (United States)

    Chen, Ke; Zhou, Xinlei; Gong, Zhenfeng; Yu, Shaochen; Qu, Chao; Guo, Min; Yu, Qingxu

    2018-01-01

    We demonstrate a new scheme of cantilever-enhanced photoacoustic spectroscopy, combining a sensitivity-improved fiber-optic cantilever acoustic sensor with a tunable high-power fiber laser, for trace gas detection. The Fabry-Perot interferometer based cantilever acoustic sensor has advantages such as high sensitivity, small size, easy to install and immune to electromagnetic. Tunable erbium-doped fiber ring laser with an erbium-doped fiber amplifier is used as the light source for acoustic excitation. In order to improve the sensitivity for photoacoustic signal detection, a first-order longitudinal resonant photoacoustic cell with the resonant frequency of 1624 Hz and a large size cantilever with the first resonant frequency of 1687 Hz are designed. The size of the cantilever is 2.1 mm×1 mm, and the thickness is 10 μm. With the wavelength modulation spectrum and second-harmonic detection methods, trace ammonia (NH3) has been measured. The gas detection limits (signal-to-noise ratio = 1) near the wavelength of 1522.5 nm is achieved to be 3 ppb.

  20. Chondroitin sulfate iron colloid-enhanced MR imaging of hepatocellular carcinoma; Correlation between histologic grade and detectability

    Energy Technology Data Exchange (ETDEWEB)

    Kamba, Masayuki; Suto, Yuji; Kodama, Fumiko; Kato, Terumi; Ohta, Yoshio; Horie, Yasushi; Hamazoe, Ryuichi; Kawasaki, Hironaka (Tottori Univ., Yonago (Japan). School of Medicine)

    1994-03-01

    We applied chondroitin sulfate iron colloid (CSIC) as an MR contrast agent to detect hepatocellular carcinoma (HCC). The MR and pathologic findings of 25 HCCs in 21 patients were analyzed. MR imaging was performed with a superconducting system operating at 1.5 T. Proton density-weighted (PDW), T[sub 2]-weighted (T[sub 2]W) and T[sub 1]-weighted (T[sub 1]W) images were obtained before and after an intravenous injection of 23.6 [mu]mol Fe/kg of CSIC. In moderately to poorly differentiated and moderately differentiated HCCs (n=15), all the lesions except a 5-mm satellite nodule were detectable with unenhanced T[sub 2]W images as well as CSIC-enhanced PDW, T[sub 2]W and T[sub 1]W images. In well to moderately differentiated HCCs (n=6), two to four lesions were detectable with unenhanced images. All the lesions except a 3-mm satellite nodule were detectable with CSIC-enhanced PDW, T[sub 2]W and T[sub 1]W images. In well differentiated HCCs (n=4), one or two lesions were detectable with unenhanced images. All the lesions were detectable with CSIC-enhanced T[sub 1]W images, while only two lesions were detectable with CSIC-enhanced PDW or T[sub 2]W images. CSIC administration improves detection rates, and is especially useful in detecting small foci of well to moderately or well differentiated HCC. (author).

  1. A Simple Metallothionein-Based Biosensor for Enhanced Detection of Arsenic and Mercury

    Directory of Open Access Journals (Sweden)

    Gordon W. Irvine

    2017-03-01

    Full Text Available Metallothioneins (MTs are a family of cysteine-rich proteins whose biological roles include the regulation of essential metal ions and protection against the harmful effects of toxic metals. Due to its high affinity for many toxic, soft metals, recombinant human MT isoform 1a was incorporated into an electrochemical-based biosensor for the detection of As3+ and Hg2+. A simple design was chosen to maximize its potential in environmental monitoring and MT was physically adsorbed onto paper discs placed on screen-printed carbon electrodes (SPCEs. This system was tested with concentrations of arsenic and mercury typical of contaminated water sources ranging from 5 to 1000 ppb. The analytical performance of the MT-adsorbed paper discs on SPCEs demonstrated a greater than three-fold signal enhancement and a lower detection limit compared to blank SPCEs, 13 ppb for As3+ and 45 ppb for Hg2+. While not being as low as some of the recommended drinking water limits, the sensitivity of the simple MT-biosensor would be potentially useful in monitoring of areas of concern with a known contamination problem. This paper describes the ability of the metal binding protein metallothionein to enhance the effectiveness of a simple, low-cost electrochemical sensor.

  2. Detection of acute avascular necrosis with dynamic contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Nadel, S.N.; Richardson, W.J.; Martinez, S.; Rizk, W.S.; Malizos, K.; Debatin, J.F.

    1991-01-01

    Early detection of avascular necrosis (AVN) may allow earlier intervention and lead to improved treatment success. This paper is designed to compare standard and dynamic contrast-enhanced MR imaging in the detection of acute AVN. A previously described animal model of AVN was used. Five anesthetized dogs underwent right femoral head devascularization, including placement of a supercooling coil around the femoral neck. Within 3 hours the dogs were imaged in a 1.5-T Signa magnet. Standard T1-weighted, T2-weighted, and STIR images were obtained through both hips. A DiGrass sequence with 30 sequential 3.2-second T1-weighted images was used, and 0.2 mmol/kg gadoteridol was injected intravenously at the start of the sequence at 2 mL/sec with an automated injector. Following imaging, oxytetracycline was given intravenously. After 3 days the dogs were killed, and their femoral heads were extracted, coronally sectioned, and analyzed for fluorescence. T1-weighted, T2-weighted, and STIR sequences showed no marrow abnormalities on either the normal or the operated-on side. With contrast material injection, all normal areas and the unoperated portion the femoral neck and diaphysis enhanced markedly 4-9 seconds following the bolus

  3. Surface-Enhanced Raman Scattering (SERS) for Detection in Immunoassays: applications, fundamentals, and optimization

    International Nuclear Information System (INIS)

    Jeremy Daniel Driskell

    2006-01-01

    Immunoassays have been utilized for the detection of biological analytes for several decades. Many formats and detection strategies have been explored, each having unique advantages and disadvantages. More recently, surface-enhanced Raman scattering (SERS) has been introduced as a readout method for immunoassays, and has shown great potential to meet many key analytical figures of merit. This technology is in its infancy and this dissertation explores the diversity of this method as well as the mechanism responsible for surface enhancement. Approaches to reduce assay times are also investigated. Implementing the knowledge gained from these studies will lead to a more sensitive immunoassay requiring less time than its predecessors. This dissertation is organized into six sections. The first section includes a literature review of the previous work that led to this dissertation. A general overview of the different approaches to immunoassays is given, outlining the strengths and weaknesses of each. Included is a detailed review of binding kinetics, which is central for decreasing assay times. Next, the theoretical underpinnings of SERS is reviewed at its current level of understanding. Past work has argued that surface plasmon resonance (SPR) of the enhancing substrate influences the SERS signal; therefore, the SPR of the extrinsic Raman labels (ERLs) utilized in our SERS-based immunoassay is discussed. Four original research chapters follow the Introduction, each presented as separate manuscripts. Chapter 2 modifies a SERS-based immunoassay previously developed in our group, extending it to the low-level detection of viral pathogens and demonstrating its versatility in terms of analyte type, Chapter 3 investigates the influence of ERL size, material composition, and separation distance between the ERLs and capture substrate on the SERS signal. This chapter links SPR with SERS enhancement factors and is consistent with many of the results from theoretical treatments

  4. Surface-Enhanced Raman Scattering (SERS) for Detection in Immunoassays. Applications, fundamentals, and optimization

    Energy Technology Data Exchange (ETDEWEB)

    Driskell, Jeremy Daniel [Iowa State Univ., Ames, IA (United States)

    2006-08-09

    Immunoassays have been utilized for the detection of biological analytes for several decades. Many formats and detection strategies have been explored, each having unique advantages and disadvantages. More recently, surface-enhanced Raman scattering (SERS) has been introduced as a readout method for immunoassays, and has shown great potential to meet many key analytical figures of merit. This technology is in its infancy and this dissertation explores the diversity of this method as well as the mechanism responsible for surface enhancement. Approaches to reduce assay times are also investigated. Implementing the knowledge gained from these studies will lead to a more sensitive immunoassay requiring less time than its predecessors. This dissertation is organized into six sections. The first section includes a literature review of the previous work that led to this dissertation. A general overview of the different approaches to immunoassays is given, outlining the strengths and weaknesses of each. Included is a detailed review of binding kinetics, which is central for decreasing assay times. Next, the theoretical underpinnings of SERS is reviewed at its current level of understanding. Past work has argued that surface plasmon resonance (SPR) of the enhancing substrate influences the SERS signal; therefore, the SPR of the extrinsic Raman labels (ERLs) utilized in our SERS-based immunoassay is discussed. Four original research chapters follow the Introduction, each presented as separate manuscripts. Chapter 2 modifies a SERS-based immunoassay previously developed in our group, extending it to the low-level detection of viral pathogens and demonstrating its versatility in terms of analyte type, Chapter 3 investigates the influence of ERL size, material composition, and separation distance between the ERLs and capture substrate on the SERS signal. This chapter links SPR with SERS enhancement factors and is consistent with many of the results from theoretical treatments

  5. Radiometric determination in situ of the face grades in Witwatersrand gold and uranium mines

    International Nuclear Information System (INIS)

    Smit, C.J.B.

    1985-01-01

    A prototype collimated radiometric face scanner was tested in the Harmony Gold Mine. The results obtained during the pilot study indicate that in situ radiometric uranium assays are statistically indistinguishable from those obtained conventionally from channel chip samples. In addition, the study demonstrated that reasonably reliable gold estimates can be deduced from the radiometric measurements, by use of the ratio of gold to uranium within a mine. The instrumentation, calibration procedures, and background determination are described briefly

  6. Surface-enhanced Raman scattering detection of silver nanoparticles in environmental and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Huiyuan [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); Xing, Baoshan, E-mail: bx@umass.edu [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); Hamlet, Leigh C.; Chica, Andrea [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); He, Lili, E-mail: lilihe@foodsci.umass.edu [Department of Food Science, University of Massachusetts, Amherst, MA 01003 (United States)

    2016-06-01

    Growing concerns over the potential release and threat of silver nanoparticles (AgNPs) to environmental and biological systems urge researchers to investigate their fate and behavior. However, current analytical techniques cannot meet the requirements for rapidly, sensitively and reliably probing AgNPs in complex matrices. Surface-enhanced Raman spectroscopy (SERS) has shown great capability for rapid detection of AgNPs based on an indicator molecule that can bind on the AgNP surface. The objective of this study was to exploit SERS to detect AgNPs in environmental and biological samples through optimizing the Raman indicator for SERS. Seven indicator molecules were selected and determined to obtain their SERS signals at optimal concentrations. Among them, 1,2-di(4-pyridyl)ethylene (BPE), crystal violet and ferric dimethyl-dithiocarbamate (ferbam) produced the highest SERS intensities. Further experiments on binding competition between each two of the three candidates showed that ferbam had the highest AgNPs-binding ability. The underlying mechanism lies in the strong binding affinity of ferbam with AgNPs via multiple sulfur atoms. We further validated ferbam to be an effective indicator for SERS detection of as low as 0.1 mg/L AgNPs in genuine surface water and 0.57 mg/L in spinach juice. Moreover, limited interference on SERS detection of AgNPs was found from environmentally relevant inorganic ions, organic matter, inorganic particles, as well as biologically relevant components, demonstrating the ferbam-assisted SERS is an effective and sensitive method to detect AgNPs in complex environmental and biological samples. - Graphical abstract: SERS signal intensity of ferbam indicates the concentration of AgNPs. - Highlights: • Ferbam was found to be the best indicator for SERS detection of AgNPs. • SERS was able to detect AgNPs in both environmental and biological samples. • Major components in the two matrices had limited effect on AgNP detection.

  7. Surface-enhanced Raman scattering detection of silver nanoparticles in environmental and biological samples

    International Nuclear Information System (INIS)

    Guo, Huiyuan; Xing, Baoshan; Hamlet, Leigh C.; Chica, Andrea; He, Lili

    2016-01-01

    Growing concerns over the potential release and threat of silver nanoparticles (AgNPs) to environmental and biological systems urge researchers to investigate their fate and behavior. However, current analytical techniques cannot meet the requirements for rapidly, sensitively and reliably probing AgNPs in complex matrices. Surface-enhanced Raman spectroscopy (SERS) has shown great capability for rapid detection of AgNPs based on an indicator molecule that can bind on the AgNP surface. The objective of this study was to exploit SERS to detect AgNPs in environmental and biological samples through optimizing the Raman indicator for SERS. Seven indicator molecules were selected and determined to obtain their SERS signals at optimal concentrations. Among them, 1,2-di(4-pyridyl)ethylene (BPE), crystal violet and ferric dimethyl-dithiocarbamate (ferbam) produced the highest SERS intensities. Further experiments on binding competition between each two of the three candidates showed that ferbam had the highest AgNPs-binding ability. The underlying mechanism lies in the strong binding affinity of ferbam with AgNPs via multiple sulfur atoms. We further validated ferbam to be an effective indicator for SERS detection of as low as 0.1 mg/L AgNPs in genuine surface water and 0.57 mg/L in spinach juice. Moreover, limited interference on SERS detection of AgNPs was found from environmentally relevant inorganic ions, organic matter, inorganic particles, as well as biologically relevant components, demonstrating the ferbam-assisted SERS is an effective and sensitive method to detect AgNPs in complex environmental and biological samples. - Graphical abstract: SERS signal intensity of ferbam indicates the concentration of AgNPs. - Highlights: • Ferbam was found to be the best indicator for SERS detection of AgNPs. • SERS was able to detect AgNPs in both environmental and biological samples. • Major components in the two matrices had limited effect on AgNP detection.

  8. Unibert - PC software for radiometric level gauging - the LB440 measuring system

    International Nuclear Information System (INIS)

    Mann, H.; Bickert, M.

    2001-01-01

    In almost all industrial branches radiometric measuring systems are being used today for a lot of different tasks. The most common field of this application are level gauging measurements by use of gamma radiation, i.e. for level detection as well as for level gauging over ranges of up to several meters. For our level gauge measuring system LB440 we developed a clearly arranged PC software, which allows starting, measuring and service of the level gauge. Over the RS232-interface the industrial computer can be connected with a Laptop or PC. The software is a supplemental or even a substitute for the operation over the frontpanel. The measuring system can be completely controlled by the Unibert PC-Software, realised by LabVIEW 5.1.1, which offers an interactive graphical user interface. The same functionality as in the ''embedded - software'' is available, completed with some additional functions. (orig.) [de

  9. A radiometric method for the determination of NADH in subpicomole amounts

    International Nuclear Information System (INIS)

    Weber, G.; Rosenthal, W.; Oberdisse, E.

    1988-01-01

    A radiometric method has been devised for the determination of small quantities of NADH formed in preceding dehydrogenase reactions. In a coupled enzymatic reaction, phosphoglycerate kinase (PGK) catalyzes the transfer of [/sup 32/P]orthophosphate from [gamma-/sup 32/P]ATP to 3-phosphoglycerate; the intermediate, 1,3-[1-/sup 32/P]diphosphoglycerate, is dephosphorylated by glyceraldehyde-3-phosphate dehydrogenase (GAP-DH). [/sup 32/P]Orthophosphate is released proportionally to NADH and can be measured after adsorption of [gamma-/sup 32/P]ATP to activated charcoal. With this method, 0.2 pmol of NADH are detectable in the presence of a 10/sup 4/-fold excess of NAD over NADH

  10. Anomalies from aerial spectrometric and total count radiometric surveys in the southeastern United States

    International Nuclear Information System (INIS)

    Lee, C.H.; Lawton, D.E.

    1978-01-01

    Aerial radiometric reconnaissance surveys are conducted because of their cost, time, and manpower savings compared to surface studies. Two types of aerial surveys are being flown in the southeastern United States: total count gamma-ray surveys for the Coastal Plains Regional Commission and the US Geological Survey, and differential gamma-ray spectrometric surveys for the US Department of Energy. Anomalous radioactivity detected during aerial surveys is related to higher concentrations of naturally occurring uranium, or to cultural activities, natural causes, or mapping errors which simulate real uranium anomalies. Each anomaly should be ground checked; however, several types of anomalies may be eliminated by evaluation of the aerial data in the office if field time is limited

  11. An attempt to evaluate some regression models used for radiometric ash determination in the brown coal

    International Nuclear Information System (INIS)

    Karamuz, S.; Urbanski, P.; Antoniak, W.; Wagner, D.

    1984-01-01

    Five different regression models for determination of the ash as well as iron and calcium contents in brown coal using fluorescence and scattering of X-rays have been evaluated. Calculations were done using experimental results obtained from the natural brown coal samples to which appropriate quantities of iron, calcium and silicon oxides were added. The secondary radiation was excited by Pu-238 source and detected by X-ray argone filled proportional counter. The investigation has shown the superiority of the multiparametric models over the radiometric ash determination in the pit-coal applying aluminium filter for the correction of the influence of iron content on the intensity of scattered radiation. Standard error of estimation for the best algorithm is about three time smaler than that for algorithm simulating application of the aluminium filter. Statistical parameters of the considered algorithm were reviewed and discussed. (author)

  12. An enhanced narrow-band imaging method for the microvessel detection

    Science.gov (United States)

    Yu, Feng; Song, Enmin; Liu, Hong; Wan, Youming; Zhu, Jun; Hung, Chih-Cheng

    2018-02-01

    A medical endoscope system combined with the narrow-band imaging (NBI), has been shown to be a superior diagnostic tool for early cancer detection. The NBI can reveal the morphologic changes of microvessels in the superficial cancer. In order to improve the conspicuousness of microvessel texture, we propose an enhanced NBI method to improve the conspicuousness of endoscopic images. To obtain the more conspicuous narrow-band images, we use the edge operator to extract the edge information of the narrow-band blue and green images, and give a weight to the extracted edges. Then, the weighted edges are fused with the narrow-band blue and green images. Finally, the displayed endoscopic images are reconstructed with the enhanced narrow-band images. In addition, we evaluate the performance of enhanced narrow-band images with different edge operators. Experimental results indicate that the Sobel and Canny operators achieve the best performance of all. Compared with traditional NBI method of Olympus company, our proposed method has more conspicuous texture of microvessel.

  13. Kernel-Based Relevance Analysis with Enhanced Interpretability for Detection of Brain Activity Patterns

    Directory of Open Access Journals (Sweden)

    Andres M. Alvarez-Meza

    2017-10-01

    Full Text Available We introduce Enhanced Kernel-based Relevance Analysis (EKRA that aims to support the automatic identification of brain activity patterns using electroencephalographic recordings. EKRA is a data-driven strategy that incorporates two kernel functions to take advantage of the available joint information, associating neural responses to a given stimulus condition. Regarding this, a Centered Kernel Alignment functional is adjusted to learning the linear projection that best discriminates the input feature set, optimizing the required free parameters automatically. Our approach is carried out in two scenarios: (i feature selection by computing a relevance vector from extracted neural features to facilitating the physiological interpretation of a given brain activity task, and (ii enhanced feature selection to perform an additional transformation of relevant features aiming to improve the overall identification accuracy. Accordingly, we provide an alternative feature relevance analysis strategy that allows improving the system performance while favoring the data interpretability. For the validation purpose, EKRA is tested in two well-known tasks of brain activity: motor imagery discrimination and epileptic seizure detection. The obtained results show that the EKRA approach estimates a relevant representation space extracted from the provided supervised information, emphasizing the salient input features. As a result, our proposal outperforms the state-of-the-art methods regarding brain activity discrimination accuracy with the benefit of enhanced physiological interpretation about the task at hand.

  14. Contrast-enhanced Ultrasound for Detection of Crohn's Disease Activity: Systematic Review and Meta-analysis.

    Science.gov (United States)

    Serafin, Zbigniew; Białecki, Marcin; Białecka, Agnieszka; Sconfienza, Luca Maria; Kłopocka, Maria

    2016-03-01

    Reports on imaging of active Crohn's disease (aCD) using contrast-enhanced ultrasound (CEUS) are encouraging. However, the statistical power of most published papers is limited due to the small size of the patient groups included. This study was performed to verify the diagnostic value of CEUS in detecting aCD. A systematic literature search was performed by two independent reviewers for articles on the test characteristics of CEUS for the identification of aCD. The quality of the analysed studies was evaluated using a quality assessment tool for diagnostic accuracy studies (QUADAS-2). Pooling was performed using a diagnostic random-effect model and bivariate analysis. Eight articles were included in the final analysis, with a total of 332 patients. There was no significant publication bias. Significant heterogeneity was found regarding CEUS methodology and sonographic definitions of aCD. In a bivariate analysis, pooled sensitivity was 0.94 (95% CI 0.87-0.97) and pooled specificity was 0.79 (95% CI 0.67-0.88). Spearman correlation statistics presented no significant diagnostic threshold effect (r = 0.12, p > 0.9). Subgroup analysis showed that relative intestine wall enhancement had the highest diagnostic value (area under the curve 94%), while the presence of enhancement and analysis of the slope were less useful (area under the curve 91 and 90%, respectively). CEUS presents good sensitivity and moderate specificity in the detection of the aCD. Large-scale randomized trials with quantitative evaluation of CEUS images are necessary to promote this technique in clinical practice. Copyright © 2015 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  15. Semi-automated scar detection in delayed enhanced cardiac magnetic resonance images

    Science.gov (United States)

    Morisi, Rita; Donini, Bruno; Lanconelli, Nico; Rosengarden, James; Morgan, John; Harden, Stephen; Curzen, Nick

    2015-06-01

    Late enhancement cardiac magnetic resonance images (MRI) has the ability to precisely delineate myocardial scars. We present a semi-automated method for detecting scars in cardiac MRI. This model has the potential to improve routine clinical practice since quantification is not currently offered due to time constraints. A first segmentation step was developed for extracting the target regions for potential scar and determining pre-candidate objects. Pattern recognition methods are then applied to the segmented images in order to detect the position of the myocardial scar. The database of late gadolinium enhancement (LE) cardiac MR images consists of 111 blocks of images acquired from 63 patients at the University Hospital Southampton NHS Foundation Trust (UK). At least one scar was present for each patient, and all the scars were manually annotated by an expert. A group of images (around one third of the entire set) was used for training the system which was subsequently tested on all the remaining images. Four different classifiers were trained (Support Vector Machine (SVM), k-nearest neighbor (KNN), Bayesian and feed-forward neural network) and their performance was evaluated by using Free response Receiver Operating Characteristic (FROC) analysis. Feature selection was implemented for analyzing the importance of the various features. The segmentation method proposed allowed the region affected by the scar to be extracted correctly in 96% of the blocks of images. The SVM was shown to be the best classifier for our task, and our system reached an overall sensitivity of 80% with less than 7 false positives per patient. The method we present provides an effective tool for detection of scars on cardiac MRI. This may be of value in clinical practice by permitting routine reporting of scar quantification.

  16. Detection of motion artifacts in optical coherence tomography using the fundus enhancement system

    International Nuclear Information System (INIS)

    Schaudig, U.; Skevas, C.; Scholz, F.

    2007-01-01

    Extensive artefacts due to major eye movements are detectable in optical coherence tomography images (OCT), but frequency and extent of small eye movements have not been studied. To investigate frequency and extent of irregularities in OCT imaging due to eye movements during the scanning process in OCT. A fundus enhancement system (FES) originally designed to improve retinal image quality in a conventional OCT device (Zeiss Stratus OCT) in order to integrate OCT images into fluorescence angiographies was used to record the scanning process and review OCT-scan acquisition in slow motion. A horizontal and a vertical single line scan of 5 mm length through the center of fixation were obtained in 40 eyes of 20 normal healthy subjects, all with a visual acuity of at least 20/20. Scans were investigated for loss of fixation and eye movements during the scanning process. Outcome measures were presence or absence of eye movements during the scanning process and mean deviation from the intended scan position, measured in millimeter. 7 of 20 patients showed no eye movements in both eyes. 4 of the remaining 13 patients showed eye movements only in one eye. In the eyes with detectable movements, the mean deviation from the intended scan position was 0.2 mm in the horizontal and 0.28 mm in the vertical scans. Fundus imaging in conventional systems can be enhanced to detect artifacts due to minimal eye movements during the scanning process. In this first series with normal healthy subjects, minimal eye movements were present in the over half of the investigations. Although the distances from the intended scan positions seem to be small in normal eyes, further investigations of the phenomenon are necessary. OCT is increasingly used as the primary tool for controlling therapy in macular diseases and the extent of motion artefacts is not known. (author) [de

  17. Ground Radiometric Method as a Tool for Determining the Surface Boundary of a Buried Bauxitic Karst

    Directory of Open Access Journals (Sweden)

    Kamal Kareem Ali

    2011-12-01

    Full Text Available Forty two ground radiometric measurements along nine traverses within a rectangular network area were taken across a bauxitic karst within the Ubaid Formation (Lower Jurassic in the Western Desert of Iraq. A 4-Channel Gamma Ray Spectrometer (GAD-6 with sodium iodide NaI (Tl crystal (GSP-4S was used in the field to measure the total radioactivity of the surface soil. Soil samples collected from the surface at each measurement point and core samples collected from a test well penetrating the karst were analyzed by Gamma ray spectrometer. The main objective of this study was to detect the hidden bauxitic karst and determine its surface boundary. The radioactivity on the surface of the karst was ranging between 60 and 80 count per second (c/s, while the background radioactivity of the Ubaid Formation, which hosts the karst, was ranging between 100 and150 c/s. Chemical weathering, especially dissolution and leaching moved uranium (238U and thorium(232Th from the overburden downward. Accordingly, these elements have been adsorbed on the surface of clay minerals and bauxite buried at a depth of about 5m causing enrichment with radioactivity. The leached overburden lack radioelements, so its radioactivity was less than background radioactivity level. The gamma ray spectroanalysis showed that the radioactivity of 238U and 232Th in the overburden was 0.5 and 3 Bq/Kg, whereas, in the bauxite and flint clay bed, it was 240 and 160 Bq/Kg respectively. Based on the radioactivity anomaly contrast on the surface, an isorad map was plotted and the karst diameter which represents low anomaly was determined to be ranging from 150 to 200m. The current study demonstrates that the ground radiometric method is quite useful for detecting the bauxitic karst and inferring its surface boundaries.

  18. Diurnal remote sensing of coastal/oceanic waters: a radiometric analysis for Geostationary Coastal and Air Pollution Events.

    Science.gov (United States)

    Pahlevan, Nima; Lee, Zhongping; Hu, Chuanmin; Schott, John R

    2014-02-01

    Optical remote sensing systems aboard geostationary platforms can provide high-frequency observations of bio-optical properties in dynamical coastal/oceanic waters. From the end-user standpoint, it is recognized that the fidelity of daily science products relies heavily on the radiometric sensitivity/performance of the imaging system. This study aims to determine the theoretical detection limits for bio-optical properties observed diurnally from a geostationary orbit. The analysis is based upon coupled radiative transfer simulations and the minimum radiometric requirements defined for the GEOstationary Coastal and Air Pollution Events (GEO-CAPE) mission. The diurnal detection limits are found for the optically active constituents of water, including near-surface concentrations of chlorophyll-a (CHL) and total suspended solids (TSS), and the absorption of colored dissolved organic matter (aCDOM). The diurnal top-of-atmosphere radiance (Lt) is modeled for several locations across the field of regard (FOR) to investigate the radiometric sensitivity at different imaging geometries. It is found that, in oceanic waters (CHL=0.07  mg/m3), detecting changes smaller than 0.01  mg/m3 in CHL is feasible for all locations and hours except for late afternoon observations on the edge of the FOR. For more trophic/turbid waters (0.6detecting the changes larger than 0.02  m(-1) (0.08detectable from early morning to late afternoon across the entire FOR. This study gives insights into the radiometric sensitivity of the GEO-CAPE mission in identifying the changes in bio-optical properties at top-of-atmosphere (TOA), which aids in a more lucid

  19. The Fate of Inhaled Nanoparticles: Detection and Measurement by Enhanced Dark-field Microscopy.

    Science.gov (United States)

    Mercer, Robert R; Scabilloni, James F; Wang, Liying; Battelli, Lori A; Antonini, James M; Roberts, Jenny R; Qian, Yong; Sisler, Jennifer D; Castranova, Vincent; Porter, Dale W; Hubbs, Ann F

    2018-01-01

    Assessing the potential health risks for newly developed nanoparticles poses a significant challenge. Nanometer-sized particles are not generally detectable with the light microscope. Electron microscopy typically requires high-level doses, above the physiologic range, for particle examination in tissues. Enhanced dark-field microscopy (EDM) is an adaption of the light microscope that images scattered light. Nanoparticles scatter light with high efficiency while normal tissues do not. EDM has the potential to identify the critical target sites for nanoparticle deposition and injury in the lungs and other organs. This study describes the methods for EDM imaging of nanoparticles and applications. Examples of EDM application include measurement of deposition and clearance patterns. Imaging of a wide variety of nanoparticles demonstrated frequent situations where nanoparticles detected by EDM were not visible by light microscopy. EDM examination of colloidal gold nanospheres (10-100 nm diameter) demonstrated a detection size limit of approximately 15 nm in tissue sections. EDM determined nanoparticle volume density was directly proportional to total lung burden of exposed animals. The results confirm that EDM can determine nanoparticle distribution, clearance, transport to lymph nodes, and accumulation in extrapulmonary organs. Thus, EDM substantially improves the qualitative and quantitative microscopic evaluation of inhaled nanoparticles.

  20. Non-invasive optical detection of HBV based on serum surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Zheng, Zuci; Wang, Qiwen; Weng, Cuncheng; Lin, Xueliang; Lin, Yao; Feng, Shangyuan

    2016-10-01

    An optical method of surface-enhanced Raman spectroscopy (SERS) was developed for non-invasive detection of hepatitis B surface virus (HBV). Hepatitis B virus surface antigen (HBsAg) is an established serological marker that is routinely used for the diagnosis of acute or chronic hepatitis B virus(HBV) infection. Utilizing SERS to analyze blood serum for detecting HBV has not been reported in previous literature. SERS measurements were performed on two groups of serum samples: one group for 50 HBV patients and the other group for 50 healthy volunteers. Blood serum samples are collected from healthy control subjects and patients diagnosed with HBV. Furthermore, principal components analysis (PCA) combined with linear discriminant analysis (LDA) were employed to differentiate HBV patients from healthy volunteer and achieved sensitivity of 80.0% and specificity of 74.0%. This exploratory work demonstrates that SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of HBV.

  1. Effect of parameters in moving average method for event detection enhancement using phase sensitive OTDR

    Science.gov (United States)

    Kwon, Yong-Seok; Naeem, Khurram; Jeon, Min Yong; Kwon, Il-bum

    2017-04-01

    We analyze the relations of parameters in moving average method to enhance the event detectability of phase sensitive optical time domain reflectometer (OTDR). If the external events have unique frequency of vibration, then the control parameters of moving average method should be optimized in order to detect these events efficiently. A phase sensitive OTDR was implemented by a pulsed light source, which is composed of a laser diode, a semiconductor optical amplifier, an erbium-doped fiber amplifier, a fiber Bragg grating filter, and a light receiving part, which has a photo-detector and high speed data acquisition system. The moving average method is operated with the control parameters: total number of raw traces, M, number of averaged traces, N, and step size of moving, n. The raw traces are obtained by the phase sensitive OTDR with sound signals generated by a speaker. Using these trace data, the relation of the control parameters is analyzed. In the result, if the event signal has one frequency, then the optimal values of N, n are existed to detect the event efficiently.

  2. Surface-enhanced Raman scattering based nonfluorescent probe for multiplex DNA detection.

    Science.gov (United States)

    Sun, Lan; Yu, Chenxu; Irudayaraj, Joseph

    2007-06-01

    To provide rapid and accurate detection of DNA markers in a straightforward, inexpensive, and multiplex format, an alternative surface-enhanced Raman scattering based probe was designed and fabricated to covalently attach both DNA probing sequence and nonfluorescent Raman tags to the surface of gold nanoparticles (DNA-AuP-RTag). The intensity of Raman signal of the probes could be controlled through the surface coverage of the nonfluorescent Raman tags (RTags). Detection sensitivity of these probes could be optimized by fine-tuning the amount of DNA molecules and RTags on the probes. Long-term stability of the DNA-AuP-RTag probes was found to be good (over 3 months). Excellent multiplexing capability of the DNA-AuP-RTag scheme was demonstrated by simultaneous identification of up to eight probes in a mixture. Detection of hybridization of single-stranded DNA to its complementary targets was successfully accomplished with a long-term goal to use nonfluorescent RTags in a Raman-based DNA microarray platform.

  3. Narrow Band Imaging Enhances the Detection Rate of Penetration and Aspiration in FEES.

    Science.gov (United States)

    Nienstedt, Julie C; Müller, Frank; Nießen, Almut; Fleischer, Susanne; Koseki, Jana-Christiane; Flügel, Till; Pflug, Christina

    2017-06-01

    Narrow band imaging (NBI) is widely used in gastrointestinal, laryngeal, and urological endoscopy. Its original purpose was to visualize vessels and epithelial irregularities. Based on our observation that adding NBI to common white light (WL) improves the contrast of the test bolus in fiberoptic endoscopic evaluation of swallowing (FEES), we now investigated the potential value of NBI in swallowing disorders. 148 FEES images were analyzed from 74 consecutive patients with swallowing disorders, including 74 with and 74 without NBI. All images were evaluated by four dysphagia specialists. Findings were classified according to Rosenbek's penetration-aspiration scale modified for evaluating these FEES images. Intra- and inter-rater reliability was determined as well as observer confidence. A better visualization of the bolus is the main advantage of NBI in FEES. This generally leads to sharper optical contrasts and better detection of small bolus quantities. Accordingly, NBI enhances the detection rate of penetration and aspiration. On average, identification of laryngeal penetration increased from 40 to 73% and of aspiration from 13 to 24% (each p dysphagia evaluation and shortening FEES evaluation time. It leads to a markedly higher detection rate of pathological findings. The significantly better intra- and inter-rater reliability argues further for a better overall reproducibly of FEES interpretation.

  4. Comparison of detection pattern of HCC by ferumoxide-enhanced MRI and intratumoral blood flow pattern

    International Nuclear Information System (INIS)

    Itou, Naoki; Kotake, Fumio; Saitou, Kazuhiro; Abe, Kimihiko

    2000-01-01

    We compared the detection rate and pattern of ferumoxide-enhanced magnetic resonance imaging (Fe-MRI) with the intratumoral blood flow pattern determined by CT angiography (CTA) and CT portography (CTAP) in 124 nodes (34 cases) diagnosed as hepatocellular carcinoma (HCC) or borderline HCC, based on the clinical course. Sequences to obtain a T1-weighted images (T1W), proton density-weighted images (PDW), T2-weighted images (T2W), T2*-weighted images (T2*W) were used in Fe-MRI. In nodes shown to be hypervascular on CTA, the detection rate by Fe-MRI was 69.7%. In nodes shown to be avascular by CTAP, the detection rate by Fe-MRI was 67.3%. These rates were higher than with other flow patterns. In nodes showing high signal intensity (HSI) on any sequences, arterial blood flow was increased and portal blood flow decreased in comparison with nodes without high signal intensity. All nodes showing HSI, both on Fe-MRI T2W and T2*W, were hypervascular on CTA, and portal blood flow was absent on CTAP. Nodes showing HSI on both T2*W and T2W were considered to have greater arterial blood flow and decreased portal blood flow compared with nodes appearing as HSI on T2*W, but only as iso- or low signal intensity on T2W (Mann-Whitney U-test; p<0.05). (author)

  5. Detection of Biomolecular Binding Through Enhancement of Localized Surface Plasmon Resonance (LSPR by Gold Nanoparticles

    Directory of Open Access Journals (Sweden)

    Min-Gon Kim

    2009-03-01

    Full Text Available To amplify the difference in localized surface plasmon resonance (LSPR spectra of gold nano-islands due to intermolecular binding events, gold nanoparticles were used. LSPR-based optical biosensors consisting of gold nano-islands were readily made on glass substrates using evaporation and heat treatment. Streptavidin (STA and biotinylated bovine serum albumin (Bio-BSA were chosen as the model receptor and the model analyte, respectively, to demonstrate the effectiveness of this detection method. Using this model system, we were able to enhance the sensitivity in monitoring the binding of Bio-BSA to gold nano-island surfaces functionalized with STA through the addition of gold nanoparticle-STA conjugates. In addition, SU-8 well chips with gold nano-island surfaces were fabricated through a conventional UV patterning method and were then utilized for image detection using the attenuated total reflection mode. These results suggest that the gold nano-island well chip may have the potential to be used for multiple and simultaneous detection of various bio-substances.

  6. A Nanosensor for TNT Detection Based on Molecularly Imprinted Polymers and Surface Enhanced Raman Scattering

    Directory of Open Access Journals (Sweden)

    Mikella E. Hankus

    2011-03-01

    Full Text Available We report on a new sensor strategy that integrates molecularly imprinted polymers (MIPs with surface enhanced Raman scattering (SERS. The sensor was developed to detect the explosive, 2,4,6-trinitrotoluene (TNT. Micron thick films of sol gel-derived xerogels were deposited on a SERS-active surface as the sensing layer. Xerogels were molecularly imprinted for TNT using non-covalent interactions with the polymer matrix. Binding of the TNT within the polymer matrix results in unique SERS bands, which allow for detection and identification of the molecule in the MIP. This MIP-SERS sensor exhibits an apparent dissociation constant of (2.3 ± 0.3 × 10−5 M for TNT and a 3 µM detection limit. The response to TNT is reversible and the sensor is stable for at least 6 months. Key challenges, including developing a MIP formulation that is stable and integrated with the SERS substrate, and ensuring the MIP does not mask the spectral features of the target analyte through SERS polymer background, were successfully met. The results also suggest the MIP-SERS protocol can be extended to other target analytes of interest.

  7. Surface-enhanced Raman scattering (SERS)-based volatile organic compounds (VOCs) detection using plasmonic bimetallic nanogap substrate

    DEFF Research Database (Denmark)

    Wong, Chi Lok; Dinish, U. S.; Buddharaju, Kavitha Devi

    2014-01-01

    In this paper, we present surface-enhanced Raman scattering (SERS)-based volatile organic compounds (VOCs) detection with bimetallic nanogap structure substrate. Deep UV photolithography at the wavelength of 250 nm is used to pattern circular shape nanostructures. The nanogap between adjacent cir......-based VOCs detection platform for point-of-care breath analysis, homeland security, chemical sensing and environmental monitoring....

  8. A new radiometric unit of measure to characterize SWIR illumination

    Science.gov (United States)

    Richards, A.; Hübner, M.

    2017-05-01

    We propose a new radiometric unit of measure we call the `swux' to unambiguously characterize scene illumination in the SWIR spectral band between 0.8μm-1.8μm, where most of the ever-increasing numbers of deployed SWIR cameras (based on standard InGaAs focal plane arrays) are sensitive. Both military and surveillance applications in the SWIR currently suffer from a lack of a standardized SWIR radiometric unit of measure that can be used to definitively compare or predict SWIR camera performance with respect to SNR and range metrics. We propose a unit comparable to the photometric illuminance lux unit; see Ref. [1]. The lack of a SWIR radiometric unit becomes even more critical if one uses lux levels to describe SWIR sensor performance at twilight or even low light condition, since in clear, no-moon conditions in rural areas, the naturally-occurring SWIR radiation from nightglow produces a much higher irradiance than visible starlight. Thus, even well-intentioned efforts to characterize a test site's ambient illumination levels in the SWIR band may fail based on photometric instruments that only measure visible light. A study of this by one of the authors in Ref. [2] showed that the correspondence between lux values and total SWIR irradiance in typical illumination conditions can vary by more than two orders of magnitude, depending on the spectrum of the ambient background. In analogy to the photometric lux definition, we propose the SWIR irradiance equivalent `swux' level, derived by integration over the scene SWIR spectral irradiance weighted by a spectral sensitivity function S(λ), a SWIR analog of the V(λ) photopic response function.

  9. LFI Radiometric Chain Assembly (RCA) data handling ``Rachel''

    Science.gov (United States)

    Malaspina, M.; Franceschi, E.; Battaglia, P.; Binko, P.; Butler, R. C.; D'Arcangelo, O.; Fogliani, S.; Frailis, M.; Franceschet, C.; Galeotta, S.; Gasparo, F.; Gregorio, A.; Lapolla, M.; Leonardi, R.; Maggio, G.; Mandolesi, N.; Manzato, P.; Maris, M.; Meharga, M.; Meinhold, P.; Morisset, N.; Pasian, F.; Perrotta, F.; Rohlfs, R.; Sandri, M.; Tomasi, M.; Türler, M.; Zacchei, A.; Zonca, A.

    2009-12-01

    Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.

  10. LFI Radiometric Chain Assembly (RCA) data handling 'Rachel'

    International Nuclear Information System (INIS)

    Malaspina, M; Franceschi, E; Butler, R C; Mandolesi, N; Battaglia, P; Franceschet, C; Lapolla, M; Binko, P; Meharga, M; D'Arcangelo, O; Fogliani, S; Frailis, M; Galeotta, S; Gasparo, F; Maggio, G; Manzato, P; Maris, M; Gregorio, A; Leonardi, R; Meinhold, P

    2009-01-01

    Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.

  11. Virtual and remote experiments for radiometric and photometric measurements

    International Nuclear Information System (INIS)

    Thoms, L-J; Girwidz, R

    2017-01-01

    The analysis of spectra is fundamental to our modern understanding of wave optics and colour perception. Since spectrometers are expensive, and accurate calibration is necessary to achieve high quality spectra, we developed a remote lab on optical spectrometry. With this tool, students can carry out real experiments over the Internet. In this article the pros and cons of remote labs, the physical background of optical spectrometry, and the development and use of a radiometric remote lab for higher education are discussed. The remote lab is freely accessible to everyone at http://virtualremotelab.net. (paper)

  12. A report of airbone radiometric and magnetic test survey

    International Nuclear Information System (INIS)

    Koo, J.H.; Park, Y.S.; Woo, S.M.

    1982-01-01

    By the end of Oct. 1981, a complete set of GeoMetrics' air-borne radiometric and magnetic survey system was purchased by KIER using the ADB loan, and it took one week from Nov. 11 1981 to install the system on a Bell 206 B helicopter (HL 9102) owned by Asia Aeroservice Company. The test survey was flown over an area including Hongseong, Daecheon, Seosan and Manripo Sheets, from Nov. 19 to Dec. 14 1981. A Hongseong air-strip was used as the base. (Author)

  13. Notes on the radiometric and geochemical survey of Leyte Island

    International Nuclear Information System (INIS)

    Santos, G. Jr.

    1982-01-01

    Radioactivity measurements using the Scintrex GIS-4 portable scintillometer were conducted along the periphery of the island. These radiometric readings as well as sediments were obtained along the streams draining into the sea. A total of 174 stream sediments samples were collected. Minus 80 mesh sediment fraction was analyzed for mobile or extractable uranium. Results indicated that the background values of radioactivity and uranium in stream sediments were 25 counts per second (cps) and 0.3 ppm, respectively. The San Isidro and Vilaba areas which are located in the northern part of Leyte have greater than 3 times above background radioactivity and uranium in the stream sediments. (author)

  14. Process system of radiometric and magnetometric aerial information

    International Nuclear Information System (INIS)

    Bazua Rueda, L.F.

    1985-01-01

    The author has been working first in the National Institute of Nuclear Energy (Mexico) and then in URAMEX (Uranio Mexicano) since 1975 to 1983, integrated to radiometric and magnetometric aerial prospecting projects in computerized processing of information aspects. During this period the author participated in the work out of computing systems, information processing and mathematical procedures definition for the geophysical reduction of the calibration equipment data. With cumulated experience, in this thesis are presented aspects concerning to management and operation of computerized processing of information systems. Operation handbooks of the majority of modules are presented. Program lists are not included. (Author)

  15. Virtual and remote experiments for radiometric and photometric measurements

    Science.gov (United States)

    Thoms, L.-J.; Girwidz, R.

    2017-09-01

    The analysis of spectra is fundamental to our modern understanding of wave optics and colour perception. Since spectrometers are expensive, and accurate calibration is necessary to achieve high quality spectra, we developed a remote lab on optical spectrometry. With this tool, students can carry out real experiments over the Internet. In this article the pros and cons of remote labs, the physical background of optical spectrometry, and the development and use of a radiometric remote lab for higher education are discussed. The remote lab is freely accessible to everyone at http://virtualremotelab.net.

  16. Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source

    Science.gov (United States)

    Coles, James B.; Richardson, Brandon S.; Eastwood, Michael L.; Sarture, Charles M.; Quetin, Gregory R.; Porter, Michael D.; Green, Robert O.; Nolte, Scott H.; Hernandez, Marco A.; Knoll, Linley A.

    2013-01-01

    The Onboard Calibration (OBC) source incorporates a medical/scientific-grade halogen source with a precisely designed fiber coupling system, and a fiber-based intensity-monitoring feedback loop that results in radiometric and spectral stabilities to within less than 0.3 percent over a 15-hour period. The airborne imaging spectrometer systems developed at the Jet Propulsion Laboratory incorporate OBC sources to provide auxiliary in-use system calibration data. The use of the OBC source will provide a significant increase in the quantitative accuracy, reliability, and resulting utility of the spectral data collected from current and future imaging spectrometer instruments.

  17. Preliminary Evaluation of GAOFEN-3 Polarimetric and Radiometric Accuracy by Corner Reflectors in Inner Mongolia

    Science.gov (United States)

    Shi, L.; Ding, X.; Li, P.; Yang, J.; Zhao, L.; Yang, L.; Chang, Y.; Yan, L.

    2018-04-01

    On August 10, 2016, China launched its first C-band full polarimetric radar satellite, named Gaofen-3 (GF-3), for urban and agriculture monitoring, landslide detection, ocean applications, etc. According to the design specification, GF-3 is expected to work at -35 dB crosstalk and 0.5 dB channel imbalance, with less than 10 degree error. The absolute radiometric bias is expected to be less than 1.5 dB in a single scene and 2.0 dB when operating for a long time. To complete the calibration and evaluation, the Institute of Electronics, Chinese Academy Sciences (IECAS) built a test site at Inner Mongolia, and deployed active reflectors (ARs) and trihedral corner reflectors (CRs) to solve and evaluate the hardware distortion. To the best of the authors' knowledge, the product accuracy of GF-3 has not been comprehensively evaluated in any open publication. The remote sensing community urgently requires a detailed report about the product accuracy and stability, before any subsequent application. From June to August of 2017, IECAS begun its second round ground campaign and deployed 10 CRs to evaluate product distortions. In this paper, we exploit Inner Mongolia CRs to investigate polarimetric and radiometric accuracy of QPSI I Stripmap. Although some CRs found fall into AR side lobe, the rest CRs enable us to preliminarily evaluate the accuracy of some special imaging beams. In the experimental part, the image of July 6, 2017 was checked by 5 trihedral CRs and the integration estimation method demonstrated the crosstalk varying from -42.65 to -32.74 dB, and the channel imbalance varying from -0.21 to 0.47 with phase error from -2.4 to 0.2 degree. Comparing with the theoretical radar cross-section of 1.235 m trihedral CR, i.e. 35 dB, the radiometric error varies about 0.20 ± 0.29 dB in HH channel and 0.40 ± 0.20 dB in VV channel.

  18. The Importance of Post-Launch, On-Orbit Absolute Radiometric Calibration for Remote Sensing Applications

    Science.gov (United States)

    Kuester, M. A.

    2015-12-01

    Remote sensing is a powerful tool for monitoring changes on the surface of the Earth at a local or global scale. The use of data sets from different sensors across many platforms, or even a single sensor over time, can bring a wealth of information when exploring anthropogenic changes to the environment. For example, variations in crop yield and health for a specific region can be detected by observing changes in the spectral signature of the particular species under study. However, changes in the atmosphere, sun illumination and viewing geometries during image capture can result in inconsistent image data, hindering automated information extraction. Additionally, an incorrect spectral radiometric calibration will lead to false or misleading results. It is therefore critical that the data being used are normalized and calibrated on a regular basis to ensure that physically derived variables are as close to truth as is possible. Although most earth observing sensors are well-calibrated in a laboratory prior to launch, a change in the radiometric response of the system is inevitable due to thermal, mechanical or electrical effects caused during the rigors of launch or by the space environment itself. Outgassing and exposure to ultra-violet radiation will also have an effect on the sensor's filter responses. Pre-launch lamps and other laboratory calibration systems can also fall short in representing the actual output of the Sun. A presentation of the differences in the results of some example cases (e.g. geology, agriculture) derived for science variables using pre- and post-launch calibration will be presented using DigitalGlobe's WorldView-3 super spectral sensor, with bands in the visible and near infrared, as well as in the shortwave infrared. Important defects caused by an incomplete (i.e. pre-launch only) calibration will be discussed using validation data where available. In addition, the benefits of using a well-validated surface reflectance product will be

  19. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. I. Salicylic, acetylosalicylic, benzoic acids

    Energy Technology Data Exchange (ETDEWEB)

    Toelgyessy, J; Dillinger, P [Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia). Chemickotechnologicka Fakulta; Harangozo, M; Jombik, J [Komenskeho Univ., Bratislava (Czechoslovakia). Farmaceuticka Fakulta

    1980-01-01

    A method for the determination of salicylic, acetylsalicylic and benzoic acids in officinal pharmaceutical based on radiometric titration with 0.1 mol.l/sup -1/ NaOH was developed. The end-point was detected with the aid of radioactive glass kryptonate. After the end-point, the excess titrant attacks the glass surface layers and this results in releasing /sup 85/Kr, and consequently, in decreasing the radioactivity of the kryptonate employed. The radioactive kryptonate used as an indicator was prepared by the bombardment of glass with accelerated /sup 85/Kr ions. The developed method is simple, accurate and correct.

  20. Detection of mast cell secretion by using surface enhanced Raman scattering

    Science.gov (United States)

    Li, Juan; Li, Ren; Zheng, Liqin; Wang, Yuhua; Xie, Shusen; Lin, Juqiang

    2016-10-01

    Acupuncture can cause a remarkable increase in degranulation of the mast cells, which has attracted the interest of researchers since the 1980s. Surface-enhanced Raman scattering (SERS) could obtain biochemical information with high sensitivity and specificity. In this study, SERS was used to detect the degree of degranulation of mast cells according to different incubate time. Mast cells was incubated with culture medium for 0 h, 12 h and 24 h, then centrifuge the culture medium, decant the supernatant, and discard the mast cell. SERS was performed to obtain the biochemical fingerprinting signatures of the centrifuged medium. The spectra data are then analyzed by spectral peaks attribution and the principal component analysis (PCA). The measured Raman spectra of the two groups were separated well by PCA. It indicated that mast cells had secreted some substances into cultured medium though degranulation did not happen.

  1. Radiometric, geometric, and image quality assessment of ALOS AVNIR-2 and PRISM sensors

    Science.gov (United States)

    Saunier, S.; Goryl, P.; Chander, G.; Santer, R.; Bouvet, M.; Collet, B.; Mambimba, A.; Kocaman, Aksakal S.

    2010-01-01

    The Advanced Land Observing Satellite (ALOS) was launched on January 24, 2006, by a Japan Aerospace Exploration Agency (JAXA) H-IIA launcher. It carries three remote-sensing sensors: 1) the Advanced Visible and Near-Infrared Radiometer type 2 (AVNIR-2); 2) the Panchromatic Remote-Sensing Instrument for Stereo Mapping (PRISM); and 3) the Phased-Array type L-band Synthetic Aperture Radar (PALSAR). Within the framework of ALOS Data European Node, as part of the European Space Agency (ESA), the European Space Research Institute worked alongside JAXA to provide contributions to the ALOS commissioning phase plan. This paper summarizes the strategy that was adopted by ESA to define and implement a data verification plan for missions operated by external agencies; these missions are classified by the ESA as third-party missions. The ESA was supported in the design and execution of this plan by GAEL Consultant. The verification of ALOS optical data from PRISM and AVNIR-2 sensors was initiated 4 months after satellite launch, and a team of principal investigators assembled to provide technical expertise. This paper includes a description of the verification plan and summarizes the methodologies that were used for radiometric, geometric, and image quality assessment. The successful completion of the commissioning phase has led to the sensors being declared fit for operations. The consolidated measurements indicate that the radiometric calibration of the AVNIR-2 sensor is stable and agrees with the Landsat-7 Enhanced Thematic Mapper Plus and the Envisat MEdium-Resolution Imaging Spectrometer calibration. The geometrical accuracy of PRISM and AVNIR-2 products improved significantly and remains under control. The PRISM modulation transfer function is monitored for improved characterization.

  2. Design Enhancements of the Fourier Kelvin Stellar Interferometer to Enable Detection of Earth Twins

    Science.gov (United States)

    Barry, Richard K.; Danchi, William C.; Lopez, Bruno; Rinehart, Stephan; Augereau, Jean-Charles; Beust, Herve; Bonfils, Xavier; Borde, Pascal; Kern, Pierre; Leger, Alain; hide

    2009-01-01

    During the last few years, considerable effort has been directed towards very large-scale (> $5 billion) missions to detect and characterize Mars-radius to Earth-radius planets around nearby stars; such as the Terrestrial Planet Finder Interferometer and Darwin missions. However, technological issues such as formation flying and control of systematic noise sources will likely prevent these missions from entering Phase A until at least the end of the next decade. Presently more than 350 planets have been discovered by a variety of techniques, and little is known about the majority of them other than their approximate mass. However, a simplified nulling interferometer operating in the near- to mid-infrared (e.g. approx. 5-15 microns), like the enhanced version of the Fourier Kelvin Stellar Interferometer (FKSI), can characterize the atmospheres of a large sample of the known planets - including Earth twins. Many other scientific problems can be addressed with a system like FKSI, including the studies of debris disks, active galactic nuclei, and low mass companions around nearby stars. We report results of a recent engineering study on an enhanced version of FKSI that includes 1-meter primary mirrors, 20-meter boom length, and an advanced sun shield that will provide a 45-degree FOR and 40K operating temperature for all optics including siderostats.

  3. Blood culture cross contamination associated with a radiometric analyzer

    International Nuclear Information System (INIS)

    Griffin, M.R.; Miller, A.D.; Davis, A.C.

    1982-01-01

    During a 9-day period in August 1980 in a New Jersey hospital, three pairs of consecutively numbered blood cultures from different patients were identified as positive for the same organism, for each pair, both cultures were positive in the same atmosphere, both organisms had the same sensitivities, and the second of each pair grew at least 2 days after the first and was the only positive blood culture obtained from the patient. When the hospital laboratory discontinued use of its radiometric culture analyzer for 15 days, no more consecutive pairs of positive cultures occurred. Subsequent use of the machine for 9 days with a new power unit but the original circuit boards resulted in one more similar consecutive pair (Staphylococcus epidermidis). After replacement of the entire power unit, there were no further such pairs. Examination of the machine by the manufacturer revealed a defective circuit board which resulted in inadequate needle sterilization. Laboratories which utilize radiometric analyzers should be aware of the potential for cross contamination. Recognition of such events requires alert microbiologists and infection control practitioners and a record system in the bacteriology laboratory designed to identify such clusters

  4. Reduction of Radiometric Miscalibration—Applications to Pushbroom Sensors

    Directory of Open Access Journals (Sweden)

    Sigrid Roessner

    2011-06-01

    Full Text Available The analysis of hyperspectral images is an important task in Remote Sensing. Foregoing radiometric calibration results in the assignment of incident electromagnetic radiation to digital numbers and reduces the striping caused by slightly different responses of the pixel detectors. However, due to uncertainties in the calibration some striping remains. This publication presents a new reduction framework that efficiently reduces linear and nonlinear miscalibrations by an image-driven, radiometric recalibration and rescaling. The proposed framework—Reduction Of Miscalibration Effects (ROME—considering spectral and spatial probability distributions, is constrained by specific minimisation and maximisation principles and incorporates image processing techniques such as Minkowski metrics and convolution. To objectively evaluate the performance of the new approach, the technique was applied to a variety of commonly used image examples and to one simulated and miscalibrated EnMAP (Environmental Mapping and Analysis Program scene. Other examples consist of miscalibrated AISA/Eagle VNIR (Visible and Near Infrared and Hawk SWIR (Short Wave Infrared scenes of rural areas of the region Fichtwald in Germany and Hyperion scenes of the Jalal-Abad district in Southern Kyrgyzstan. Recovery rates of approximately 97% for linear and approximately 94% for nonlinear miscalibrated data were achieved, clearly demonstrating the benefits of the new approach and its potential for broad applicability to miscalibrated pushbroom sensor data.

  5. Radiometric calibration of digital cameras using neural networks

    Science.gov (United States)

    Grunwald, Michael; Laube, Pascal; Schall, Martin; Umlauf, Georg; Franz, Matthias O.

    2017-08-01

    Digital cameras are used in a large variety of scientific and industrial applications. For most applications, the acquired data should represent the real light intensity per pixel as accurately as possible. However, digital cameras are subject to physical, electronic and optical effects that lead to errors and noise in the raw image. Temperature- dependent dark current, read noise, optical vignetting or different sensitivities of individual pixels are examples of such effects. The purpose of radiometric calibration is to improve the quality of the resulting images by reducing the influence of the various types of errors on the measured data and thus improving the quality of the overall application. In this context, we present a specialized neural network architecture for radiometric calibration of digital cameras. Neural networks are used to learn a temperature- and exposure-dependent mapping from observed gray-scale values to true light intensities for each pixel. In contrast to classical at-fielding, neural networks have the potential to model nonlinear mappings which allows for accurately capturing the temperature dependence of the dark current and for modeling cameras with nonlinear sensitivities. Both scenarios are highly relevant in industrial applications. The experimental comparison of our network approach to classical at-fielding shows a consistently higher reconstruction quality, also for linear cameras. In addition, the calibration is faster than previous machine learning approaches based on Gaussian processes.

  6. Off-line radiometric analysis of Planck-LFI data

    Energy Technology Data Exchange (ETDEWEB)

    Tomasi, M; Mennella, A; Bersanelli, M [Dipartimento di Fisica, Universita degli Studi di Milano, Via Celoria 16, 20133 Milano (Italy); Galeotta, S; Maris, M [LFI-DPC INAF-OATs, Via Tiepolo 11, 34131 Trieste (Italy); Lowe, S R [Jodrell Bank Centre for Astrophysics, The University of Manchester, Manchester, M13 9PL (United Kingdom); Mendes, L [Planck Science Office, European Space Agency, ESAC, P.O. box 78, 28691 Villanueva de la Canada, Madrid (Spain); Leonardi, R; Meinhold, P [Department of Physics, University of California, Santa Barbara, CA 93106-9530 (United States); Villa, F; Sandri, M; Cuttaia, F; Terenzi, L; Valenziano, L; Butler, R C [INAF-IASF Bologna, Via Gobetti, 101, 40129, Bologna (Italy); Cappellini, B [INAF-IASF Milano, Via E. Bassini 15, 20133 Milano (Italy); Gregorio, A [Department of Physics, University of Trieste, Via Valerio, 2 Trieste I-34127 (Italy); Salmon, M J [Departamento de IngenierIa de Comunicaciones, Universidad de Cantabria, Avenida de los Castros s/n. 39005 Santander (Spain); Binko, P [ISDC Data Centre for Astrophysics, University of Geneva, ch. d' Ecogia 16, 1290 Versoix (Switzerland); D' Arcangelo, O, E-mail: tomasi@lambrate.inaf.i [IFP-CNR, Via Cozzi 53, Milano (Italy)

    2009-12-15

    The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.

  7. Off-line radiometric analysis of Planck-LFI data

    International Nuclear Information System (INIS)

    Tomasi, M; Mennella, A; Bersanelli, M; Galeotta, S; Maris, M; Lowe, S R; Mendes, L; Leonardi, R; Meinhold, P; Villa, F; Sandri, M; Cuttaia, F; Terenzi, L; Valenziano, L; Butler, R C; Cappellini, B; Gregorio, A; Salmon, M J; Binko, P; D'Arcangelo, O

    2009-01-01

    The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.

  8. A COMPARISON OF LIDAR REFLECTANCE AND RADIOMETRICALLY CALIBRATED HYPERSPECTRAL IMAGERY

    Directory of Open Access Journals (Sweden)

    A. Roncat

    2016-06-01

    Full Text Available In order to retrieve results comparable under different flight parameters and among different flight campaigns, passive remote sensing data such as hyperspectral imagery need to undergo a radiometric calibration. While this calibration, aiming at the derivation of physically meaningful surface attributes such as a reflectance value, is quite cumbersome for passively sensed data and relies on a number of external parameters, the situation is by far less complicated for active remote sensing techniques such as lidar. This fact motivates the investigation of the suitability of full-waveform lidar as a “single-wavelength reflectometer” to support radiometric calibration of hyperspectral imagery. In this paper, this suitability was investigated by means of an airborne hyperspectral imagery campaign and an airborne lidar campaign recorded over the same area. Criteria are given to assess diffuse reflectance behaviour; the distribution of reflectance derived by the two techniques were found comparable in four test areas where these criteria were met. This is a promising result especially in the context of current developments of multi-spectral lidar systems.

  9. Automated gamma spectrometry and data analysis on radiometric neutron dosimeters

    International Nuclear Information System (INIS)

    Matsumoto, W.Y.

    1983-01-01

    An automated gamma-ray spectrometry system was designed and implemented by the Westinghouse Hanford Company at the Hanford Engineering Development Laboratory (HEDL) to analyze radiometric neutron dosimeters. Unattended, automatic, 24 hour/day, 7 day/week operation with online data analysis and mainframe-computer compatible magnetic tape output are system features. The system was used to analyze most of the 4000-plus radiometric monitors (RM's) from extensive reactor characterization tests during startup and initial operation of th Fast Flux Test Facility (FFTF). The FFTF, operated by HEDL for the Department of Energy, incorporates a 400 MW(th) sodium-cooled fast reactor. Aumomated system hardware consists of a high purity germanium detector, a computerized multichannel analyzer data acquisition system (Nuclear Data, Inc. Model 6620) with two dual 2.5 Mbyte magnetic disk drives plus two 10.5 inch reel magnetic tape units for mass storage of programs/data and an automated Sample Changer-Positioner (ASC-P) run with a programmable controller. The ASC-P has a 200 sample capacity and 12 calibrated counting (analysis) positions ranging from 6 inches (15 cm) to more than 20 feet (6.1 m) from the detector. The system software was programmed in Fortran at HEDL, except for the Nuclear Data, Inc. Peak Search and Analysis Program and Disk Operating System (MIDAS+)

  10. Radiometric titration of thallium(III) with EDTA

    International Nuclear Information System (INIS)

    Rao, V.R.S.; Pulla Rao, Ch.; Tataiah, G.

    1978-01-01

    Radioactive solutions containing very small amounts of thallium(III) can be determined by radiometric titration using ammonia as hydrolysing agent. Aqueous solution of thallium(I) (both inactive and radioactive) is treated with bromine water till the appearance of the brown colour of bromine, and the solution is warmed to 80 deg C to expel the excess bromine. By this procedure all thallium(I) is quantitatively oxidised to thallium(III). An aqueous solution of ammonia is added to precipitate thallium(III) as thallic oxide. It is then filtered, washed with water to free it from bromide and then dissolved in 2N HCl and the solution is then standardised. 2 ml of this solution is transferred to a 20 ml volumetric flask, 1 ml of radioactive thallium(III) solution to be standardised is added as well as incremental amounts of EDTA solution and mixed thoroughly. Uncomplexed thallium(III) is then precipitated by the addition of an ammonia solution and diluted to 20 ml. Required amount of this mixture is centrifuged. The beta activity of the supernatant aliquot is measured using a GM counter. Quantitative determination of Tl(III) in the range of 1-10 μM can be carried out. The interference of cations such as Au(III), iron(III), Ga(III) can be eliminated by pretreatment of the Tl(III) solution before carrying out radiometric titration. The results obtained are reproducible and accurate to +-3%. (T.I.)

  11. Air Kerma above environmental radiometric calibration facility for field equipment

    International Nuclear Information System (INIS)

    Conti, C.C.; Sachett, I.A.; Bertelli, L.; Lopes, R.T.

    2000-01-01

    The use of gamma ray spectrometers broadened the aims of gamma ray surveys, stead of measuring only the gross radiation, as was done with the GM tubes, it is now possible to be used for uranium exploration, geological mapping as an aid to the exploration of non radioactive ores like gold and tin, radiation background measurements to identify hot spots for radiation hazard evaluation and environmental monitoring of fallout from radiological and nuclear accidents. It became necessary to carefully and precisely calibrate the field equipment to be used to get all the information from such uses. There is an environmental radiometric calibration facility for field equipment, consisting of eight radioactive concrete sources, at the Institute of Radioprotection and Dosimetry - IRD (CNEN/Brazil). These sources are cylindrical with 3 m diameter, 0.5 m thick and weigh about 7.5 tons each. The amount and type of the radioactive material, 238 U and 232 Th and 40 K ores in secular radioactive equilibrium, added to the concrete to simulate rock outcrops, varies in order to obtain different gamma fields, varying in both energy and intensity. These different radiation fields were measured with a HPGe portable detector, specifically calibrated for spectrum stripping, and the air kerma energy distribution was determined for each concrete source and compared with the total air kerma calculated from the nuclide concentration and by others radiometric methods. (author)

  12. Reduction of Radiometric Miscalibration—Applications to Pushbroom Sensors

    Science.gov (United States)

    Rogaß, Christian; Spengler, Daniel; Bochow, Mathias; Segl, Karl; Lausch, Angela; Doktor, Daniel; Roessner, Sigrid; Behling, Robert; Wetzel, Hans-Ulrich; Kaufmann, Hermann

    2011-01-01

    The analysis of hyperspectral images is an important task in Remote Sensing. Foregoing radiometric calibration results in the assignment of incident electromagnetic radiation to digital numbers and reduces the striping caused by slightly different responses of the pixel detectors. However, due to uncertainties in the calibration some striping remains. This publication presents a new reduction framework that efficiently reduces linear and nonlinear miscalibrations by an image-driven, radiometric recalibration and rescaling. The proposed framework—Reduction Of Miscalibration Effects (ROME)—considering spectral and spatial probability distributions, is constrained by specific minimisation and maximisation principles and incorporates image processing techniques such as Minkowski metrics and convolution. To objectively evaluate the performance of the new approach, the technique was applied to a variety of commonly used image examples and to one simulated and miscalibrated EnMAP (Environmental Mapping and Analysis Program) scene. Other examples consist of miscalibrated AISA/Eagle VNIR (Visible and Near Infrared) and Hawk SWIR (Short Wave Infrared) scenes of rural areas of the region Fichtwald in Germany and Hyperion scenes of the Jalal-Abad district in Southern Kyrgyzstan. Recovery rates of approximately 97% for linear and approximately 94% for nonlinear miscalibrated data were achieved, clearly demonstrating the benefits of the new approach and its potential for broad applicability to miscalibrated pushbroom sensor data. PMID:22163960

  13. The Pelindaba facility for calibrating radiometric field instruments

    International Nuclear Information System (INIS)

    Corner, B.; Toens, P.D.; Van As, D.; Vleggaar, C.M.; Richards, D.J.

    1979-04-01

    The tremendous upsurge in uranium exploration activity, experienced in recent years, has made the need for the standardisation and calibration of radiometric field instruments apparent. In order to fulfill this need, construction of a calibration facility at the National Nuclear Research Centre, Pelindaba, was commenced in 1972 and has since been extended according the the requirements of the mining industry. The facility currently comprises 11 surface standard sources suitable for the calibration, in terms of radio-element concentration, of portable scintillometers and spectrometers, and single uranium and thorium model-borehole sources which make possible the accurate calibration of borehole logging instruments both for gross-count and spectrometric surveys. Portable potassium, uranium and thorium sources are also available for the purposes of establishing airborne-spectrometer stripping ratios. The relevant physico-chemical properties of the standards are presented in this report and calibration procedures and data reduction techniques recommended. Examples are given of in situ measurements, both on surface and down-the-hole, which show that the derived calibration constants yield radiometric grades which are, on average, accurate to within 5% of the true radio-element concentrations. A secondary facility comprising single borehole- and surface-uranium sources has also been constructed in Beaufort West in the southern Karoo [af

  14. Radiometric titration of diethanolamine with 65ZnSO4 and determination of mono and diethanolamines in a mixture by a radiometric method

    International Nuclear Information System (INIS)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S.

    1984-01-01

    Radiometric titration of diethanolamine with 65 ZnSO 4 is reported. Determination of individual amounts of mono- and diethanolamines in a mixture is described. The procedure is simple, rapid and accurate. (author)

  15. Radiometric titration of diethanolamine with /sup 65/ZnSO/sub 4/ and determination of mono and diethanolamines in a mixture by a radiometric method

    Energy Technology Data Exchange (ETDEWEB)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S. (Indian Inst. of Tech., Madras. Dept. of Chemistry)

    1984-08-16

    Radiometric titration of diethanolamine with /sup 65/ZnSO/sub 4/ is reported. Determination of individual amounts of mono- and diethanolamines in a mixture is described. The procedure is simple, rapid and accurate.

  16. Indirect glyphosate detection based on ninhydrin reaction and surface-enhanced Raman scattering spectroscopy

    Science.gov (United States)

    Xu, Meng-Lei; Gao, Yu; Li, Yali; Li, Xueliang; Zhang, Huanjie; Han, Xiao Xia; Zhao, Bing; Su, Liang

    2018-05-01

    Glyphosate is one of the most commonly-used and non-selective herbicides in agriculture, which may directly pollute the environment and threaten human health. A simple and effective approach to assessment of its damage to the natural environment is thus quite necessary. However, traditional chromatography-based detection methods usually suffer from complex pretreatment procedures. Herein, we propose a simple and sensitive method for the determination of glyphosate by combining ninhydrin reaction and surface-enhanced Raman scattering (SERS) spectroscopy. The product (purple color dye, PD) of the ninhydrin reaction is found to SERS-active and directly correlate with the glyphosate concentration. The limit of detection of the proposed method for glyphosate is as low as 1.43 × 10- 8 mol·L- 1 with a relatively wider linear concentration range (1.0 × 10- 7-1.0 × 10- 4 mol·L- 1), which demonstrates its great potential in rapid, highly sensitive concentration determination of glyphosate in practical applications for safety assessment of food and environment.

  17. Information-Aided Smart Schemes for Vehicle Flow Detection Enhancements of Traffic Microwave Radar Detectors

    Directory of Open Access Journals (Sweden)

    Tan-Jan Ho

    2016-07-01

    Full Text Available For satisfactory traffic management of an intelligent transport system, it is vital that traffic microwave radar detectors (TMRDs can provide real-time traffic information with high accuracy. In this study, we develop several information-aided smart schemes for traffic detection improvements of TMRDs in multiple-lane environments. Specifically, we select appropriate thresholds not only for removing noise from fast Fourier transforms (FFTs of regional lane contexts but also for reducing FFT side lobes within each lane. The resulting FFTs of reflected vehicle signals and those of clutter are distinguishable. We exploit FFT and lane-/or time stamp-related information for developing smart schemes, which mitigate adverse effects of lane-crossing FFT side lobes of a vehicle signal. As such, the proposed schemes can enhance the detection accuracy of both lane vehicle flow and directional traffic volume. On-site experimental results demonstrate the advantages and feasibility of the proposed methods, and suggest the best smart scheme.

  18. Potential of non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Huang, Shaohua; Wang, Lan; Chen, Weisheng; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong

    2014-11-01

    Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA-LDA multivariate analysis has potential for non-invasive detection of esophagus cancer.

  19. Potential of non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy

    International Nuclear Information System (INIS)

    Huang, Shaohua; Wang, Lan; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong; Chen, Weisheng

    2014-01-01

    Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA–LDA multivariate analysis has potential for non-invasive detection of esophagus cancer. (letter)

  20. Odors pulsed at wing beat frequencies are tracked by primary olfactory networks and enhance odor detection

    Directory of Open Access Journals (Sweden)

    Shreejoy Tripathy

    2010-03-01

    Full Text Available Each down stroke of an insect’s wings accelerates axial airflow over the antennae. Modeling studies suggest that this can greatly enhance penetration of air and air-born odorants through the antennal sensilla thereby periodically increasing odorant-receptor interactions. Do these periodic changes result in entrainment of neural responses in the antenna and antennal lobe (AL? Does this entrainment affect olfactory acuity? To address these questions, we monitored antennal and AL responses in the moth Manduca sexta while odorants were pulsed at frequencies from 10-72 Hz, encompassing the natural wingbeat frequency. Power spectral density (PSD analysis was used to identify entrainment of neural activity. Statistical analysis of PSDs indicates that the antennal nerve tracked pulsed odor up to 30 Hz. Furthermore, at least 50% of AL local field potentials (LFPs and between 7-25% of unitary spiking responses also tracked pulsed odor up to 30 Hz in a frequency-locked manner. Application of bicuculline (200µM abolished pulse tracking in both LFP and unitary responses suggesting that GABAA receptor activation is necessary for pulse tracking within the AL. Finally, psychophysical measures of odor detection establish that detection thresholds are lowered when odor is pulsed at 20 Hz. These results suggest that AL networks can respond to the oscillatory dynamics of stimuli such as those imposed by the wing beat in a manner analogous to mammalian sniffing.

  1. Enhanced UV light detection using a p-terphenyl wavelength shifter

    Science.gov (United States)

    Joosten, S.; Kaczanowicz, E.; Ungaro, M.; Rehfuss, M.; Johnston, K.; Meziani, Z.-E.

    2017-10-01

    UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below 300 nm due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below 300 nm. A less expensive solution that dramatically improves this efficiency is the application of a thin film of a p-terphenyl (PT) wavelength shifter on UV-glass PMTs. This improvement was quantified for Photonis XP4500B PMTs for wavelengths between 200 nm and 400 nm. The gain factor ranges up to 5 . 4 ± 0 . 5 at a wavelength of 215 nm, with a material load of 110 ± 10 μg /cm2 (894 nm). The wavelength shifter was found to be fully transparent for wavelengths greater than 300 nm. The resulting gain in detection efficiency, when used in a typical C̆erenkov counter, was estimated to be of the order of 40%. Consistent coating quality was assured by a rapid gain testing procedure using narrow-band UV LEDs. Based on these results, 200 Photonis XP4500B PMTs were treated with PT for the upgraded low-threshold C̆erenkov counter (LTCC) to be used in the CEBAF Large Acceptance Spectrometer upgraded detector (CLAS12) at the Thomas Jefferson National Accelerator Facility.

  2. Radiometric geological exploration method used in the central part of the State of Sonora

    International Nuclear Information System (INIS)

    Pacheco R, R.

    1978-01-01

    The purpose of this study is to make known the importance of the radiometric data, the physical principles on which they are based and the geological interpretation which will permit in an indirect way to select important radioactive areas in order to carry out verification studies on the ground to see if there are sufficient reasons to show any interest in these areas. Till now this work has been realized in the State of Sonora (Mexico) in an area of 51,000 Km 2 subdivided in 14 zones, numbered from 201 to 214, and for the present work the zone 208 has been selected. This Zone is located at the north-west of the City of Hermosillo, and has a total area of 3400 Km 2 which has been the object of the study by plane through systematic flights in an east-west direction, in order to obtain the configuration and interpret it from a radiometrical point of view. The obtained isorads configuration plans of 4 channels of detection are the following: total counting, potassium, bismuth and thallium as well as their relations. From the 14 verified anomalies the anomaly Noche Buena was selected in order to carry out reconnaissance surveys and preliminary and detailed geological studies. The geology of the area is represented by extrusive and intrusive igneous rocks as well as sedimentary. The uraniferous mineralization is secondary and is represented by autunite, meta-autunite and torbenite which represent an average of 200 g to 3.08 Kg. of U 3 O 8 per ton. (author)

  3. Gold nanoparticles enhanced SERS aptasensor for the simultaneous detection of Salmonella typhimurium and Staphylococcus aureus.

    Science.gov (United States)

    Zhang, Hui; Ma, Xiaoyuan; Liu, Ying; Duan, Nuo; Wu, Shijia; Wang, Zhouping; Xu, Baocai

    2015-12-15

    Salmonella typhimurium and Staphylococcus aureus are most common causes of food-associated disease. A Raman based biosensor was developed for S. typhimurium and S. aureus detection simultaneously. The biosensor was based on nanoparticles enhanced Raman intensity and the specific recognition of aptamer. The Raman signal probe and the capture probe are built. Gold nanoparticles (GNPs) modified with Raman molecules (Mercaptobenzoic acid and 5,5'-Dithiobis(2-nitrobenzoic acid)) and aptamer are used as the signal probe for S. typhimurium and S. aureus, respectively. Fe3O4 magnetic gold nanoparticles (MGNPs) immobilized with both aptamer of S. typhimurium and S. aureus are used as the capture probe. When S. typhimurium and S. aureus are added in the reaction system, the capture probe will capture the target bacteria through the specific binding effect of aptamer. And then the signal probe will be connected to the bacteria also by the effect of aptamer to form the sandwich like detection structure. The Raman intensified spectrum was measured to quantify S. typhimurium and S. aureus. Under optimal conditions, the SERS intensity of MBA at 1582 cm(-1) are used to measure S. typhimurium (y=186.4762+704.8571x, R(2)=0.9921) and the SERS intensity of DNTB at 1333 cm(-1) are used to measure S. aureus (y=135.2381+211.4286x, R(2)=0.9946) in the range of 10(2)-10(7) cfu mL(-1). The LOD is 35 cfu mL(-1) for S. aureus and 15 cfu mL(-1) for S. typhimurium. This method is simple and rapid, results in high sensitivity and specificity, and can be used to detect actual samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Paleomagnetic, paleontologic and radiometric study of the Uquia Formation (Plio-Pleistocene) in Esquina Blanca (Jujuy)

    International Nuclear Information System (INIS)

    Walther, Ana M.; Orgeira, Maria J.; Vilas, Juan F.A.; Kelley, Shari; Jordan, Teresa

    1998-01-01

    A multidisciplinary study of the Uquia Formation has been performed. The results of the paleontologic, paleomagnetic, radiometric and stratigraphic analyses suggest that the superior levels of the formation are equivalent to the 'Marplatense Superior', while the basic ones should be considered older. Radiometric ages have been determined by fission tracks in zircons

  5. Radiometric mass flow probes for belt weighers - the state of the art and possibilities of application

    International Nuclear Information System (INIS)

    Glaeser, M.

    1986-01-01

    The setup of radiometric belt weighers is described in principle and compared with conventional ones. Fields of application are mentioned and a list is given of equipment comercially available. The comparison shows that the radiometric systems are advantageous in general, but in special cases (measuring error lower than 1%, chemical composition varies several 10%) gravimetric systems are indispensable

  6. Map of natural gamma radiation in Spain: radiometric characterization of different types of surfaces

    International Nuclear Information System (INIS)

    Suarez Mahou, E.; Fernandez Amigot, J.A.; Botas Medina, J.

    1997-01-01

    The gamma radioactivity flowing from ground and rocks is due to the presence in these of uranium, thorium and potassium-40. The method of radiometric characterization depends on the purpose of the undertaking. Radiometric characterization can be realized on big surfaces (tens or hundreds of square kilometres studied on a national scale), medium size surfaces (50 to 1000 square kilometres, for example, in epidemiological or biological studies in areas with a determined radiometric background) small surfaces of less than 50 square kilometres (industrial sites, pre-operational studies, etc.). This article considers aspects of radiometric characterization on surfaces of interest and describes the contribution of the MARNA (Natural Provisional Radiation Map of Spain) Project selection and radiometric characterization

  7. ORIGINAL ARTICLE: Will An Additional Observer Enhance Adenoma Detection During Colonoscopy?

    Directory of Open Access Journals (Sweden)

    Kevin D Mullen

    2012-07-01

    Full Text Available Background: Due to varied level of experience, the detection rate of adenoma on colonoscopy is different. In presence of both fellows and attending the incidence rates of adenoma are shown to increase in a small study reported by Rogart et al [4]. Based on similar hypothesis, a study was undertaken with much larger sample size to improve the power of the study. Aims and objective: To know if presence of additional observer will enhance adenoma detection during colonoscopy. Material and Methods: 2236 consecutive colonoscopies performed at Metro Health Medical Centre, Cleveland, Ohio were included in the study from July 2005 to August 2006. Cases with history of colorectal, surgical resection of colon, inflammatory bowel diseases and hereditary polyposis syndrome were excluded. Inpatient colonoscopies were also excluded. With all usual precautions for colonoscopy and after giving polyethylene glycol electrolyte (PEGEL colonoscopies were performed by one of the nine experienced staff attending using an Olympus colonoscope and Evis Exera processors. All colonoscopies performed by fellows were supervised by an attending throughout the procedure. Advanced adenomas were defined as adenomas greater than 1 cm size. Statistical analysis was done using Tall hassee, FL software; Fisher’s exact test, unpaired t test and multiple logistic regression analysis were performed. p-value of <0.05 is considered as statistically significant. Results: Of the total 2236 colonoscopies included in the study, 1527 were performed by fellows under supervision of attending and 709 by the attending. There was no significant difference in patient demographics, caecal intubation or poor preparation colonoscopies. The mean age of the group was 55 years in both of the groups. There was no statistically significant different in the polyp detection rate (35% Vs 36.8% as well as overall adenoma detection rate (28.4% Vs 27.7% between these two groups of performers. However

  8. Optimal Hotspots of Dynamic Surfaced-Enhanced Raman Spectroscopy for Drugs Quantitative Detection.

    Science.gov (United States)

    Yan, Xiunan; Li, Pan; Zhou, Binbin; Tang, Xianghu; Li, Xiaoyun; Weng, Shizhuang; Yang, Liangbao; Liu, Jinhuai

    2017-05-02

    Surface-enhanced Raman spectroscopy (SERS) as a powerful qualitative analysis method has been widely applied in many fields. However, SERS for quantitative analysis still suffers from several challenges partially because of the absence of stable and credible analytical strategy. Here, we demonstrate that the optimal hotspots created from dynamic surfaced-enhanced Raman spectroscopy (D-SERS) can be used for quantitative SERS measurements. In situ small-angle X-ray scattering was carried out to in situ real-time monitor the formation of the optimal hotspots, where the optimal hotspots with the most efficient hotspots were generated during the monodisperse Au-sol evaporating process. Importantly, the natural evaporation of Au-sol avoids the nanoparticles instability of salt-induced, and formation of ordered three-dimensional hotspots allows SERS detection with excellent reproducibility. Considering SERS signal variability in the D-SERS process, 4-mercaptopyridine (4-mpy) acted as internal standard to validly correct and improve stability as well as reduce fluctuation of signals. The strongest SERS spectra at the optimal hotspots of D-SERS have been extracted to statistics analysis. By using the SERS signal of 4-mpy as a stable internal calibration standard, the relative SERS intensity of target molecules demonstrated a linear response versus the negative logarithm of concentrations at the point of strongest SERS signals, which illustrates the great potential for quantitative analysis. The public drugs 3,4-methylenedioxymethamphetamine and α-methyltryptamine hydrochloride obtained precise analysis with internal standard D-SERS strategy. As a consequence, one has reason to believe our approach is promising to challenge quantitative problems in conventional SERS analysis.

  9. Enhanced plasma wave detection of terahertz radiation using multiple high electron-mobility transistors connected in series

    KAUST Repository

    Elkhatib, Tamer A.; Kachorovskiǐ, Valentin Yu; Stillman, William J.; Veksler, Dmitry B.; Salama, Khaled N.; Zhang, Xicheng; Shur, Michael S.

    2010-01-01

    We report on enhanced room-temperature detection of terahertz radiation by several connected field-effect transistors. For this enhanced nonresonant detection, we have designed, fabricated, and tested plasmonic structures consisting of multiple InGaAs/GaAs pseudomorphic high electron-mobility transistors connected in series. Results show a 1.63-THz response that is directly proportional to the number of detecting transistors biased by a direct drain current at the same gate-to-source bias voltages. The responsivity in the saturation regime was found to be 170 V/W with the noise equivalent power in the range of 10-7 W/Hz0.5. The experimental data are in agreement with the detection mechanism based on the rectification of overdamped plasma waves excited by terahertz radiation in the transistor channel. © 2010 IEEE.

  10. Enhanced plasma wave detection of terahertz radiation using multiple high electron-mobility transistors connected in series

    KAUST Repository

    Elkhatib, Tamer A.

    2010-02-01

    We report on enhanced room-temperature detection of terahertz radiation by several connected field-effect transistors. For this enhanced nonresonant detection, we have designed, fabricated, and tested plasmonic structures consisting of multiple InGaAs/GaAs pseudomorphic high electron-mobility transistors connected in series. Results show a 1.63-THz response that is directly proportional to the number of detecting transistors biased by a direct drain current at the same gate-to-source bias voltages. The responsivity in the saturation regime was found to be 170 V/W with the noise equivalent power in the range of 10-7 W/Hz0.5. The experimental data are in agreement with the detection mechanism based on the rectification of overdamped plasma waves excited by terahertz radiation in the transistor channel. © 2010 IEEE.

  11. Contrast-enhanced transrectal ultrasonography for the detection of diffuse prostate cancer

    International Nuclear Information System (INIS)

    Gao, Y.; Liao, X.H.; Lu, L.; Wang, L.; Ma, Y.; Qin, H.Z.; Yan, X.; Guo, P.

    2016-01-01

    Aim: To evaluate the diagnostic accuracy of contrast-enhanced transrectal ultrasonography (CE-TRUS) versus baseline TRUS (combination of grey-scale and colour Doppler imaging) for diffuse prostate cancer. Materials and methods: Forty-six patients without an obvious focal mass on baseline TRUS (grey-scale and colour Doppler), underwent additional CE-TRUS and TRUS-guided biopsy due to elevated levels of prostate-specific antigen (PSA ≥4 ng/ml) and/or abnormal digital rectal examination (DRE). In all patients, CE-TRUS was performed with intravenous injection of a contrast agent (sulphur hexafluoride microbubble; SonoVue, 2.4 ml) before biopsy. TRUS-guided biopsy targeted suspicious areas detected on CE-TRUS imaging or sampled the outer gland of the normal prostate. The final diagnosis was based on results of the TRUS-guided biopsy. The diagnostic accuracy of baseline TRUS and CE-TRUS for diffuse prostatic lesions was evaluated using receiver operating characteristic (ROC) curve analysis. Results: Diffuse prostate cancer was present in 32 (69.5%) patients and absent in 14 (30.5%) patients. Nineteen patients had diffuse prostate cancer that was not detected by baseline TRUS, whereas 15 cases were identified using CE-TRUS. Conversely, five patients had benign prostatic hypertrophy (BPH) that was diagnosed as cancer by CE-TRUS, and two of these patients were diagnosed with BPH by baseline TRUS. The combined sensitivity, specificity, and accuracy were 87.5%, 64.2%, and 80.4%, respectively, for CE-TRUS, and 40.6%, 78.5%, and 52.1%, respectively, for baseline TRUS. The area under the ROC curve (AUC) values for the diagnostic accuracy of baseline CE-TRUS versus TRUS for diffuse prostate cancer differed significantly at 0.904 and 0.667, respectively (Z=4.098, p<0.0001). Conclusion: CE-TRUS exhibited greater diagnostic accuracy for diffuse prostate cancer than baseline TRUS. CE-TRUS may improve cancer detection over baseline TRUS imaging for the diagnosis of diffuse

  12. Time-delayed contrast-enhanced MRI improves detection of brain metastases and apparent treatment volumes.

    Science.gov (United States)

    Kushnirsky, Marina; Nguyen, Vinh; Katz, Joel S; Steinklein, Jared; Rosen, Lisa; Warshall, Craig; Schulder, Michael; Knisely, Jonathan P S

    2016-02-01

    Contrast-enhanced MRI is the preeminent diagnostic test for brain metastasis (BM). Detection of BMs for stereotactic radiosurgery (SRS) planning may improve with a time delay following administration of a high-relaxivity agent for 1.5-T and 3-T imaging systems. Metastasis detection with time-delayed MRI was evaluated in this study. Fifty-three volumetric MRI studies from 38 patients undergoing SRS for BMs were evaluated. All studies used 0.1-mmol/kg gadobenate dimeglumine (MultiHance; Bracco Diagnostics) immediately after injection, followed by 2 more axial T1-weighted sequences after 5-minute intervals (final image acquisition commenced 15 minutes after contrast injection). Two studies were motion limited and excluded. Two hundred eighty-seven BMs were identified. The studies were randomized and examined separately by 3 radiologists, who were blinded to the temporal sequence. Each radiologist recorded the number of BMs detected per scan. A Wilcoxon signed-rank test compared BM numbers between scans. One radiologist determined the scan on which BMs were best defined. All confirmed, visible tumors were contoured using iPlan RT treatment planning software on each of the 3 MRI data sets. A linear mixed model was used to analyze volume changes. The interclass correlations for Scans 1, 2, and 3 were 0.7392, 0.7951, and 0.7290, respectively, demonstrating excellent interrater reliability. At least 1 new lesion was detected in the second scan as compared with the first in 35.3% of subjects (95% CI 22.4%-49.9%). The increase in BM numbers between Scans 1 and 2 ranged from 1 to 10. At least 1 new lesion was detected in the third scan as compared with the second in 21.6% of subjects (95% CI 11.3%-35.3%). The increase in BM numbers between Scans 2 and 3 ranged from 1 to 9. Between Scans 1 and 3, additional tumors were seen on 43.1% of scans (increase ranged from 1 to 14). The median increase in tumor number for all comparisons was 1. There was a significant increase in number

  13. Detection of enhancement in number densities of background galaxies due to magnification by massive galaxy clusters

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, I.; Dietrich, J. P.; Mohr, J.; Applegate, D. E.; Benson, B. A.; Bleem, L. E.; Bayliss, M. B.; Bocquet, S.; Carlstrom, J. E.; Capasso, R.; Desai, S.; Gangkofner, C.; Gonzalez, A. H.; Gupta, N.; Hennig, C.; Hoekstra, H.; von der Linden, A.; Liu, J.; McDonald, M.; Reichardt, C. L.; Saro, A.; Schrabback, T.; Strazzullo, V.; Stubbs, C. W.; Zenteno, A.

    2016-02-18

    We present a detection of the enhancement in the number densities of background galaxies induced from lensing magnification and use it to test the Sunyaev-Zel'dovich effect (SZE-) inferred masses in a sample of 19 galaxy clusters with median redshift z similar or equal to 0.42 selected from the South Pole Telescope SPT-SZ survey. These clusters are observed by the Megacam on the Magellan Clay Telescope though gri filters. Two background galaxy populations are selected for this study through their photometric colours; they have median redshifts zmedian similar or equal to 0.9 (low-z background) and z(median) similar or equal to 1.8 (high-z background). Stacking these populations, we detect the magnification bias effect at 3.3 sigma and 1.3 sigma for the low-and high-z backgrounds, respectively. We fit Navarro, Frenk and White models simultaneously to all observed magnification bias profiles to estimate the multiplicative factor. that describes the ratio of the weak lensing mass to the mass inferred from the SZE observable-mass relation. We further quantify systematic uncertainties in. resulting from the photometric noise and bias, the cluster galaxy contamination and the estimations of the background properties. The resulting. for the combined background populations with 1 sigma uncertainties is 0.83 +/- 0.24(stat) +/- 0.074(sys), indicating good consistency between the lensing and the SZE-inferred masses. We use our best-fitting eta to predict the weak lensing shear profiles and compare these predictions with observations, showing agreement between the magnification and shear mass constraints. This work demonstrates the promise of using the magnification as a complementary method to estimate cluster masses in large surveys.

  14. A comparison of radiometric correction techniques in the evaluation of the relationship between LST and NDVI in Landsat imagery.

    Science.gov (United States)

    Tan, Kok Chooi; Lim, Hwee San; Matjafri, Mohd Zubir; Abdullah, Khiruddin

    2012-06-01

    Atmospheric corrections for multi-temporal optical satellite images are necessary, especially in change detection analyses, such as normalized difference vegetation index (NDVI) rationing. Abrupt change detection analysis using remote-sensing techniques requires radiometric congruity and atmospheric correction to monitor terrestrial surfaces over time. Two atmospheric correction methods were used for this study: relative radiometric normalization and the simplified method for atmospheric correction (SMAC) in the solar spectrum. A multi-temporal data set consisting of two sets of Landsat images from the period between 1991 and 2002 of Penang Island, Malaysia, was used to compare NDVI maps, which were generated using the proposed atmospheric correction methods. Land surface temperature (LST) was retrieved using ATCOR3_T in PCI Geomatica 10.1 image processing software. Linear regression analysis was utilized to analyze the relationship between NDVI and LST. This study reveals that both of the proposed atmospheric correction methods yielded high accuracy through examination of the linear correlation coefficients. To check for the accuracy of the equation obtained through linear regression analysis for every single satellite image, 20 points were randomly chosen. The results showed that the SMAC method yielded a constant value (in terms of error) to predict the NDVI value from linear regression analysis-derived equation. The errors (average) from both proposed atmospheric correction methods were less than 10%.

  15. Retrieval of effective cloud field parameters from radiometric data

    Science.gov (United States)

    Paulescu, Marius; Badescu, Viorel; Brabec, Marek

    2017-06-01

    Clouds play a key role in establishing the Earth's climate. Real cloud fields are very different and very complex in both morphological and microphysical senses. Consequently, the numerical description of the cloud field is a critical task for accurate climate modeling. This study explores the feasibility of retrieving the effective cloud field parameters (namely the cloud aspect ratio and cloud factor) from systematic radiometric measurements at high frequency (measurement is taken every 15 s). Two different procedures are proposed, evaluated, and discussed with respect to both physical and numerical restrictions. None of the procedures is classified as best; therefore, the specific advantages and weaknesses are discussed. It is shown that the relationship between the cloud shade and point cloudiness computed using the estimated cloud field parameters recovers the typical relationship derived from measurements.

  16. Regional radiometric map of Syria, using gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Aissa, M.; Al-Hent, R.; Nasser, R.

    2005-01-01

    The regional radiometric gamma-ray spectrometry map of Syria, scaled 1/1000000, for surficial concentration of the total radioactivity (Ur), eU, eTh and %K was completely achieved after normalizing the airborne and carbon data sets to match each other. It worthy notice that, the anomalies found to be closely related to either phosphate and/or glauconite deposits. It is worth mentioning that throughout the survey work many scattered occurrences of secondary uranium mineralization were found as spots in some formations and phosphate rocks. Where this phenomena attributes to chemical and physical disseminating instead of accumulating the radioelements. So, that leads to a weak expectation for usual surface uranium deposits where attributed to the oxidizing condition. Then this expectation remains, as an open question requires answering through planning to subsurface prospecting. (Author)

  17. Development of a portable ambient temperature radiometric assaying instrument

    International Nuclear Information System (INIS)

    Lavietes, A.D.; McQuaid, J.H.; Ruhter, W.D.; Paulus, T.J.

    1995-01-01

    There is a strong need for portable radiometric instrumentation that can accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need, the authors are developing a hand-held, non-cryogenic, low-power gamma- and X-ray measurement and analysis instrument that can both search and then accurately verify the presence of nuclear materials. The authors report on the use of cadmium zinc telluride detectors, signal processing electronics, and the new field-portable instrument based on the MicroNOMAD Multichannel Analyzer from EG and G ORTEC. They will also describe the isotopic analysis that allows uranium enrichment measurements to be made accurately in the field. The benefits of this work are realized in a wide spectrum of applications that include Arms Control, Nuclear Safeguards, Environmental Management, Emergency Response, and Treaty Verification

  18. Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

    Science.gov (United States)

    Choi, Taeyoung; Xiong, Xiaxiong; Chander, G.; Angal, Amit

    2009-01-01

    The Landsat 7 (L7) Enhanced Thematic Mapper (ETM+) sensor was launched on April 15th, 1999 and has been in operation for over nine years. It has six reflective solar spectral bands located in the visible and shortwave infrared part of the electromagnetic spectrum (0.5 - 2.5 micron) at a spatial resolution of 30 m. The on-board calibrators are used to monitor the on-orbit sensor system changes. The ETM+ performs solar calibrations using on-board Full Aperture Solar Calibrator (FASC) and the Partial Aperture Solar Calibrator (PASC). The Internal Calibrator Lamp (IC) lamps, a blackbody and shutter optics constitute the on-orbit calibration mechanism for ETM+. On 31 May 2003, a malfunction of the scan-line corrector (SLC) mirror assembly resulted in the loss of approximately 22% of the normal scene area. The missing data affects most of the image with scan gaps varying in width from one pixel or less near the centre of the image to 14 pixels along the east and west edges of the image, creating a wedge-shaped pattern. However, the SLC failure has no impacts on the radiometric performance of the valid pixels. On December 18, 1999, the Moderate Resolution Imaging Spectroradiometer (MODIS) Proto-Flight Model (PFM) was launched on-board the NASA's EOS Terra spacecraft. Terra MODIS has 36 spectral bands with wavelengths ranging from 0.41 to 14.5 micron and collects data over a wide field of view angle (+/-55 deg) at three nadir spatial resolutions of 250 m, 500 in 1 km for bands 1 to 2, 3 to 7, and 8 to 36, respectively. It has 20 reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.1 micron. The RSB radiometric calibration is performed by using on-board solar diffuser (SD), solar diffuser stability monitor (SDSM), space-view (SV), and spectro-radiometric calibration assembly (SRCA). Through the SV port, periodic lunar observations are used to track radiometric response changes at different angles of incidence (AOI) of the scan mirror. As a part of the AM

  19. Does the degree of background enhancement in breast MRI affect the detection and staging of breast cancer?

    International Nuclear Information System (INIS)

    Uematsu, Takayoshi; Kasami, Masako; Watanabe, Junichiro

    2011-01-01

    The purpose of this study was to assess the influence of background enhancement on the detection and staging of breast cancer using MRI as an adjunct to mammography or ultrasound. One hundred forty-six bilateral breast MRI examinations were evaluated to assess the extent of a known primary tumour and to problem solve after mammography or ultrasound without adjusting for the phase in the patients' menstrual cycle. The background enhancement was classified into four categories by visual evaluation: minimal, mild, moderate and marked. In total, 131 histologically confirmed abnormal cases (104 malignant and 27 benign) and 15 normal cases were included in the analysis. There was no tumour size-related bias between the groups (p = 0.522). For the primary index tumour, the sensitivities of MRI with minimal/mild and moderate/marked background enhancement were 100% and 76% (p = 0.001), respectively. Thus, the degree of background enhancement did not affect the specificity. For evaluating tumour extent (n = 104), the accuracy of MRI with moderate/marked background enhancement (52%) was significantly lower than that with minimal/mild background enhancement (84%; p = 0.002). The degree of background enhancement affected the detection and staging of breast cancer using MRI. (orig.)

  20. Does the degree of background enhancement in breast MRI affect the detection and staging of breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, Takayoshi [Shizuoka Cancer Center Hospital, Breast Imaging and Breast Intervention Section, Shizuoka (Japan); Kasami, Masako [Shizuoka Cancer Center Hospital, Department of Pathology, Naga-izumi, Shizuoka (Japan); Watanabe, Junichiro [Shizuoka Cancer Center Hospital, Division of Medical Oncology, Naga-izumi, Shizuoka (Japan)

    2011-11-15

    The purpose of this study was to assess the influence of background enhancement on the detection and staging of breast cancer using MRI as an adjunct to mammography or ultrasound. One hundred forty-six bilateral breast MRI examinations were evaluated to assess the extent of a known primary tumour and to problem solve after mammography or ultrasound without adjusting for the phase in the patients' menstrual cycle. The background enhancement was classified into four categories by visual evaluation: minimal, mild, moderate and marked. In total, 131 histologically confirmed abnormal cases (104 malignant and 27 benign) and 15 normal cases were included in the analysis. There was no tumour size-related bias between the groups (p = 0.522). For the primary index tumour, the sensitivities of MRI with minimal/mild and moderate/marked background enhancement were 100% and 76% (p = 0.001), respectively. Thus, the degree of background enhancement did not affect the specificity. For evaluating tumour extent (n = 104), the accuracy of MRI with moderate/marked background enhancement (52%) was significantly lower than that with minimal/mild background enhancement (84%; p = 0.002). The degree of background enhancement affected the detection and staging of breast cancer using MRI. (orig.)

  1. Evaluation of Radiometric and Atmospheric Correction Algorithms for Aboveground Forest Biomass Estimation Using Landsat 5 TM Data

    Directory of Open Access Journals (Sweden)

    Pablito M. López-Serrano

    2016-04-01

    Full Text Available Solar radiation is affected by absorption and emission phenomena during its downward trajectory from the Sun to the Earth’s surface and during the upward trajectory detected by satellite sensors. This leads to distortion of the ground radiometric properties (reflectance recorded by satellite images, used in this study to estimate aboveground forest biomass (AGB. Atmospherically-corrected remote sensing data can be used to estimate AGB on a global scale and with moderate effort. The objective of this study was to evaluate four atmospheric correction algorithms (for surface reflectance, ATCOR2 (Atmospheric Correction for Flat Terrain, COST (Cosine of the Sun Zenith Angle, FLAASH (Fast Line-of-sight Atmospheric Analysis of Spectral Hypercubes and 6S (Second Simulation of Satellite Signal in the Solar, and one radiometric correction algorithm (for reflectance at the sensor ToA (Apparent Reflectance at the Top of Atmosphere to estimate AGB in temperate forest in the northeast of the state of Durango, Mexico. The AGB was estimated from Landsat 5 TM imagery and ancillary information from a digital elevation model (DEM using the non-parametric multivariate adaptive regression splines (MARS technique. Field reference data for the model training were collected by systematic sampling of 99 permanent forest growth and soil research sites (SPIFyS established during the winter of 2011. The following predictor variables were identified in the MARS model: Band 7, Band 5, slope (β, Wetness Index (WI, NDVI and MSAVI2. After cross-validation, 6S was found to be the optimal model for estimating AGB (R2 = 0.71 and RMSE = 33.5 Mg·ha−1; 37.61% of the average stand biomass. We conclude that atmospheric and radiometric correction of satellite images can be used along with non-parametric techniques to estimate AGB with acceptable accuracy.

  2. Analysis of the radiometric survey during the Argonauta reactor operation

    International Nuclear Information System (INIS)

    Oliveira, Eara de S.L.; Cardozo, Katia K.M.; Silva, Joao Carlos P.; Santos, Joao Regis dos

    2013-01-01

    The Argonaut reactor at the Institute of Nuclear Engineering-IEN/CNEN, operates normally, the powers between 1.7 and 340 W on neutrongraphy procedures, production of radionuclides and experimental reactor physics lessons to postgraduate courses. The doses from neutrons and gamma radiation are measured when the reactor is critical, inside the reactor hall and surrounding regions. A study of the data obtained was performed to evaluate the daily need of this survey in the reactor hall. Taking into account the principle ALARA, which aims to optimize and minimize the dose received by the individual, we propose, in this work, through an analysis of the acquired data in occupational radiometric surveys, a reformulation of the area monitoring routine practiced by the team of radiological protection of the Institute of Nuclear Engineering - IEN/CNEN-RJ, whereas other monitoring routines regarding the radiological protection are also applied in the routine of the reactor. The operations under review occurred with the reactor operating 340 W power at intervals of 60, 120 and 180 minutes, in monitoring points in controlled areas, supervised and free. The results showed significant dose values in the output of the J-Channel 9 when the operation occurs with this open. With 180 minutes of operation, the measured values of dose rate were lower than the values at 60 min and 120 operations min. At the point in the supervised area, offsite to the reactor hall, situated in the direction of the J-Channel 9, the value reduces more than 14% in any operating time in relation to the dose rate measured at the point opposite the canal. There is a 50% reduction in the dose rates for operations with and J-9 closed. The results suggest a new frequency of radiometric survey whose mode of operation is maintained in similar conditions, since combined with other relevant practices of radiation protection

  3. Accelerator physics and radiometric properties of superconducting wavelength shifters

    International Nuclear Information System (INIS)

    Scheer, Michael

    2008-01-01

    Subject of this thesis is the operation of wave-length shifters at electron storage rings and their use in radiometry. The basic aspects of the radiometry, the technical requirements, the influence of wave-length shifters on the storage ring, and results of first measurements are presented for a device installed at BESSY. Most of the calculations are carried out by the program WAVE, which has been developed within this thesis. WAVE allows to calculate the synchrotron radiation spectra of wavelength shifters within an relative uncertainty of 1/100000. The properties of wave-length shifters in terms of accelerator physics as well as a generating function for symplectic tracking calculations can also be calculated by WAVE. The later was implemented in the tracking code BETA to investigate the influence of insertion devices on the dynamic aperture and emittance of the storage ring. These studies led to the concept of alternating low- and high-beta-sections at BESSY-II, which allow to operate superconducting insertion devices without a significant distortion of the magnetic optics. To investigate the experimental aspects of the radiometry at wave-length shifters, a program based on the Monte-Carlo-code GEANT4 has been developed. It allows to simulate the radiometrical measurements and the absorption properties of detectors. With the developed codes first radiometrical measurements by the PTB have been analysed. A comparison of measurements and calculations show a reasonable agreement with deviations of about five percent in the spectral range of 40-60 keV behind a 1-mm-Cu filter. A better agreement was found between 20 keV and 80 keV without Cu filter. In this case the measured data agreed within a systematic uncertainty of two percent with the results of the calculations. (orig.)

  4. JPSS-1 VIIRS Pre-Launch Radiometric Performance

    Science.gov (United States)

    Oudrari, Hassan; McIntire, Jeff; Xiong, Xiaoxiong; Butler, James; Efremova, Boryana; Ji, Jack; Lee, Shihyan; Schwarting, Tom

    2015-01-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument was designed to provide measurements of the globe twice daily. It is a wide-swath (3,040 kilometers) cross-track scanning radiometer with spatial resolutions of 370 and 740 meters at nadir for imaging and moderate bands, respectively. It covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands [0.412 microns to 12.01 microns]. VIIRS observations are used to generate 22 environmental data products (EDRs). This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the independent government team, to generate the at-launch baseline radiometric performance, and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field and stray light responses. A set of performance metrics generated during the pre-launch testing program will be compared to the SNPP VIIRS pre-launch performance.

  5. Visual perception enhancement for detection of cancerous oral tissue by multi-spectral imaging

    International Nuclear Information System (INIS)

    Wang, Hsiang-Chen; Tsai, Meng-Tsan; Chiang, Chun-Ping

    2013-01-01

    Color reproduction systems based on the multi-spectral imaging technique (MSI) for both directly estimating reflection spectra and direct visualization of oral tissues using various light sources are proposed. Images from three oral cancer patients were taken as the experimental samples, and spectral differences between pre-cancerous and normal oral mucosal tissues were calculated at three time points during 5-aminolevulinic acid photodynamic therapy (ALA-PDT) to analyze whether they were consistent with disease processes. To check the successful treatment of oral cancer with ALA-PDT, oral cavity images by swept source optical coherence tomography (SS-OCT) are demonstrated. This system can also reproduce images under different light sources. For pre-cancerous detection, the oral images after the second ALA-PDT are assigned as the target samples. By using RGB LEDs with various correlated color temperatures (CCTs) for color difference comparison, the light source with a CCT of about 4500 K was found to have the best ability to enhance the color difference between pre-cancerous and normal oral mucosal tissues in the oral cavity. Compared with the fluorescent lighting commonly used today, the color difference can be improved by 39.2% from 16.5270 to 23.0023. Hence, this light source and spectral analysis increase the efficiency of the medical diagnosis of oral cancer and aid patients in receiving early treatment. (paper)

  6. Pattern of Breast Cancer Distribution in Ghana: A Survey to Enhance Early Detection, Diagnosis, and Treatment

    Directory of Open Access Journals (Sweden)

    Frank Naku Ghartey Jnr

    2016-01-01

    Full Text Available Background. Nearly 70% of women diagnosed with breast cancer in Ghana are in advanced stages of the disease due especially to low awareness, resulting in limited treatment success and high death rate. With limited epidemiological studies on breast cancer in Ghana, the aim of this study is to assess and understand the pattern of breast cancer distribution for enhancing early detection and treatment. Methods. We randomly selected and screened 3000 women for clinical palpable breast lumps and used univariate and bivariate analysis for description and exploration of variables, respectively, in relation to incidence of breast cancer. Results. We diagnosed 23 (0.76% breast cancer cases out of 194 (6.46% participants with clinically palpable breast lumps. Seventeen out of these 23 (0.56% were premenopausal (<46.6 years with 7 (0.23% being below 35 years. With an overall breast cancer incidence of 0.76% in this study, our observation that about 30% of these cancer cases were below 35 years may indicate a relative possible shift of cancer burden to women in their early thirties in Ghana, compared to Western countries. Conclusion. These results suggest an age adjustment for breast cancer screening to early twenties for Ghanaian women and the need for a nationwide breast cancer screening to understand completely the pattern of breast cancer distribution in Ghana.

  7. Non-invasive optical detection of esophagus cancer based on urine surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Huang, Shaohua; Wang, Lan; Chen, Weiwei; Lin, Duo; Huang, Lingling; Wu, Shanshan; Feng, Shangyuan; Chen, Rong

    2014-09-01

    A surface-enhanced Raman spectroscopy (SERS) approach was utilized for urine biochemical analysis with the aim to develop a label-free and non-invasive optical diagnostic method for esophagus cancer detection. SERS spectrums were acquired from 31 normal urine samples and 47 malignant esophagus cancer (EC) urine samples. Tentative assignments of urine SERS bands demonstrated esophagus cancer specific changes, including an increase in the relative amounts of urea and a decrease in the percentage of uric acid in the urine of normal compared with EC. The empirical algorithm integrated with linear discriminant analysis (LDA) were employed to identify some important urine SERS bands for differentiation between healthy subjects and EC urine. The empirical diagnostic approach based on the ratio of the SERS peak intensity at 527 to 1002 cm-1 and 725 to 1002 cm-1 coupled with LDA yielded a diagnostic sensitivity of 72.3% and specificity of 96.8%, respectively. The area under the receive operating characteristic (ROC) curve was 0.954, which further evaluate the performance of the diagnostic algorithm based on the ratio of the SERS peak intensity combined with LDA analysis. This work demonstrated that the urine SERS spectra associated with empirical algorithm has potential for noninvasive diagnosis of esophagus cancer.

  8. DNA-modified electrodes fabricated using copper-free click chemistry for enhanced protein detection.

    Science.gov (United States)

    Furst, Ariel L; Hill, Michael G; Barton, Jacqueline K

    2013-12-31

    A method of DNA monolayer formation has been developed using copper-free click chemistry that yields enhanced surface homogeneity and enables variation in the amount of DNA assembled; extremely low-density DNA monolayers, with as little as 5% of the monolayer being DNA, have been formed. These DNA-modified electrodes (DMEs) were characterized visually, with AFM, and electrochemically, and were found to facilitate DNA-mediated reduction of a distally bound redox probe. These low-density monolayers were found to be more homogeneous than traditional thiol-modified DNA monolayers, with greater helix accessibility through an increased surface area-to-volume ratio. Protein binding efficiency of the transcriptional activator TATA-binding protein (TBP) was also investigated on these surfaces and compared to that on DNA monolayers formed with standard thiol-modified DNA. Our low-density monolayers were found to be extremely sensitive to TBP binding, with a signal decrease in excess of 75% for 150 nM protein. This protein was detectable at 4 nM, on the order of its dissociation constant, with our low-density monolayers. The improved DNA helix accessibility and sensitivity of our low-density DNA monolayers to TBP binding reflects the general utility of this method of DNA monolayer formation for DNA-based electrochemical sensor development.

  9. Surface enhanced Raman spectroscopy detection of biomolecules using EBL fabricated nanostructured substrates.

    Science.gov (United States)

    Peters, Robert F; Gutierrez-Rivera, Luis; Dew, Steven K; Stepanova, Maria

    2015-03-20

    Fabrication and characterization of conjugate nano-biological systems interfacing metallic nanostructures on solid supports with immobilized biomolecules is reported. The entire sequence of relevant experimental steps is described, involving the fabrication of nanostructured substrates using electron beam lithography, immobilization of biomolecules on the substrates, and their characterization utilizing surface-enhanced Raman spectroscopy (SERS). Three different designs of nano-biological systems are employed, including protein A, glucose binding protein, and a dopamine binding DNA aptamer. In the latter two cases, the binding of respective ligands, D-glucose and dopamine, is also included. The three kinds of biomolecules are immobilized on nanostructured substrates by different methods, and the results of SERS imaging are reported. The capabilities of SERS to detect vibrational modes from surface-immobilized proteins, as well as to capture the protein-ligand and aptamer-ligand binding are demonstrated. The results also illustrate the influence of the surface nanostructure geometry, biomolecules immobilization strategy, Raman activity of the molecules and presence or absence of the ligand binding on the SERS spectra acquired.

  10. Derivatization reaction-based surface-enhanced Raman scattering (SERS) for detection of trace acetone.

    Science.gov (United States)

    Zheng, Ying; Chen, Zhuo; Zheng, Chengbin; Lee, Yong-Ill; Hou, Xiandeng; Wu, Li; Tian, Yunfei

    2016-08-01

    A facile method was developed for determination of trace volatile acetone by coupling a derivatization reaction to surface-enhanced Raman scattering (SERS). With iodide modified Ag nanoparticles (Ag IMNPs) as the SERS substrate, acetone without obvious Raman signal could be converted to SERS-sensitive species via a chemical derivatization reaction with 2,4-dinitrophenylhydrazine (2,4-DNPH). In addition, acetone can be effectively separated from liquid phase with a purge-sampling device and then any serious interference from sample matrices can be significantly reduced. The optimal conditions for the derivatization reaction and the SERS analysis were investigated in detail, and the selectivity and reproducibility of this method were also evaluated. Under the optimal conditions, the limit of detection (LOD) for acetone was 5mgL(-1) or 0.09mM (3σ). The relative standard deviation (RSD) for 80mgL(-1) acetone (n=9) was 1.7%. This method was successfully used for the determination of acetone in artificial urine and human urine samples with spiked recoveries ranging from 92% to 110%. The present method is convenient, sensitive, selective, reliable and suitable for analysis of trace acetone, and it could have a promising clinical application in early diabetes diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Visual perception enhancement for detection of cancerous oral tissue by multi-spectral imaging

    Science.gov (United States)

    Wang, Hsiang-Chen; Tsai, Meng-Tsan; Chiang, Chun-Ping

    2013-05-01

    Color reproduction systems based on the multi-spectral imaging technique (MSI) for both directly estimating reflection spectra and direct visualization of oral tissues using various light sources are proposed. Images from three oral cancer patients were taken as the experimental samples, and spectral differences between pre-cancerous and normal oral mucosal tissues were calculated at three time points during 5-aminolevulinic acid photodynamic therapy (ALA-PDT) to analyze whether they were consistent with disease processes. To check the successful treatment of oral cancer with ALA-PDT, oral cavity images by swept source optical coherence tomography (SS-OCT) are demonstrated. This system can also reproduce images under different light sources. For pre-cancerous detection, the oral images after the second ALA-PDT are assigned as the target samples. By using RGB LEDs with various correlated color temperatures (CCTs) for color difference comparison, the light source with a CCT of about 4500 K was found to have the best ability to enhance the color difference between pre-cancerous and normal oral mucosal tissues in the oral cavity. Compared with the fluorescent lighting commonly used today, the color difference can be improved by 39.2% from 16.5270 to 23.0023. Hence, this light source and spectral analysis increase the efficiency of the medical diagnosis of oral cancer and aid patients in receiving early treatment.

  12. RapidEye constellation relative radiometric accuracy measurement using lunar images

    Science.gov (United States)

    Steyn, Joe; Tyc, George; Beckett, Keith; Hashida, Yoshi

    2009-09-01

    The RapidEye constellation includes five identical satellites in Low Earth Orbit (LEO). Each satellite has a 5-band (blue, green, red, red-edge and near infrared (NIR)) multispectral imager at 6.5m GSD. A three-axes attitude control system allows pointing the imager of each satellite at the Moon during lunations. It is therefore possible to image the Moon from near identical viewing geometry within a span of 80 minutes with each one of the imagers. Comparing the radiometrically corrected images obtained from each band and each satellite allows a near instantaneous relative radiometric accuracy measurement and determination of relative gain changes between the five imagers. A more traditional terrestrial vicarious radiometric calibration program has also been completed by MDA on RapidEye. The two components of this program provide for spatial radiometric calibration ensuring that detector-to-detector response remains flat, while a temporal radiometric calibration approach has accumulated images of specific dry dessert calibration sites. These images are used to measure the constellation relative radiometric response and make on-ground gain and offset adjustments in order to maintain the relative accuracy of the constellation within +/-2.5%. A quantitative comparison between the gain changes measured by the lunar method and the terrestrial temporal radiometric calibration method is performed and will be presented.

  13. In situ Silver Spot Preparation and on-Plate Surface-Enhanced Raman Scattering Detection in Thin Layer Chromatography Separation

    Science.gov (United States)

    Herman, K.; Mircescu, N. E.; Szabo, L.; Leopold, L. F.; Chiş, V.; Leopold, N.

    2013-05-01

    An improved approach for surface-enhanced Raman scattering (SERS) detection of mixture constituents after thin layer chromatography (TLC) separation is presented. A SERS active silver substrate was prepared under open air conditions, directly on the thin silica film by photo-reduction of silver nitrate, allowing the detection of binary mixtures of cresyl violet, bixine, crystal violet, and Cu(II) complex of 4-(2-pyridylazo)resorcinol. The recorded SERS spectrum provides a unique spectral fingerprint for each molecule; therefore the use of analyte standards is avoided, thus rendering the presented procedure advantageous compared to the conventional detection methodology in TLC.

  14. Label-Free Detection of Glycan-Protein Interactions for Array Development by Surface-Enhanced Raman Spectroscopy (SERS)

    NARCIS (Netherlands)

    Li, Xiuru; Martin, Sharon J H; Chinoy, Zoeisha S; Liu, Lin; Rittgers, Brandon; Dluhy, Richard A; Boons, Geert-Jan

    2016-01-01

    A glyco-array platform has been developed, in which glycans are attached to plasmonic nanoparticles through strain-promoted azide-alkyne cycloaddition. Glycan-protein binding events can then be detected in a label-free manner employing surface-enhanced Raman spectroscopy (SERS). As proof of concept,

  15. Hot-Volumes as Uniform and Reproducible SERS-Detection Enhancers in Weakly-Coupled Metallic Nanohelices

    Science.gov (United States)

    Caridad, José M.; Winters, Sinéad; McCloskey, David; Duesberg, Georg S.; Donegan, John F.; Krstić, Vojislav

    2017-03-01

    Reproducible and enhanced optical detection of molecules in low concentrations demands simultaneously intense and homogeneous electric fields acting as robust signal amplifiers. To generate such sophisticated optical near-fields, different plasmonic nanostructures were investigated in recent years. These, however, exhibit either high enhancement factor (EF) or spatial homogeneity but not both. Small interparticle gaps or sharp nanostructures show enormous EFs but no near-field homogeneity. Meanwhile, approaches using rounded and separated monomers create uniform near-fields with moderate EFs. Here, guided by numerical simulations, we show how arrays of weakly-coupled Ag nanohelices achieve both homogeneous and strong near-field enhancements, reaching even the limit forreproducible detection of individual molecules. The unique near-field distribution of a single nanohelix consists of broad hot-spots, merging with those from neighbouring nanohelices in specific array configurations and generating a wide and uniform detection zone (“hot-volume”). We experimentally assessed these nanostructures via surface-enhanced Raman spectroscopy, obtaining a corresponding EF of ~107 and a relative standard deviation <10%. These values demonstrate arrays of nanohelices as state-of-the-art substrates for reproducible optical detection as well as compelling nanostructures for related fields such as near-field imaging.

  16. Swarm Intelligence-Enhanced Detection of Non-Small-Cell Lung Cancer Using Tumor-Educated Platelets

    NARCIS (Netherlands)

    Best, Myron G.; Sol, Nik; In ‘t Veld, Sjors G.J.G.; Vancura, Adrienne; Muller, Mirte; Niemeijer, Anna Larissa N.; Fejes, Aniko V.; Tjon Kon Fat, Lee Ann; Huis in 't Veld, Anna E; Leurs, Cyra; Le Large, Tessa Y.; Meijer, Laura L.; Kooi, Irsan E.; Rustenburg, François; Schellen, Pepijn; Verschueren, Heleen; Post, Edward; Wedekind, Laurine E.; Bracht, Jillian; Esenkbrink, Michelle; Wils, Leon; Favaro, Francesca; Schoonhoven, Jilian D.; Tannous, Jihane; Meijers-Heijboer, Hanne; Kazemier, Geert; Giovannetti, Elisa; Reijneveld, Jaap C.; Idema, Sander; Killestein, Joep; Heger, Michal; de Jager, Saskia C.; Urbanus, Rolf T.; Hoefer, Imo E.; Pasterkamp, Gerard; Mannhalter, Christine; Gomez-Arroyo, Jose; Bogaard, Harm-Jan; Noske, David P.; Vandertop, W. Peter; van den Broek, Daan; Ylstra, Bauke; Nilsson, R. Jonas A; Wesseling, Pieter; Karachaliou, Niki; Rosell, Rafael; Lee-Lewandrowski, Elizabeth; Lewandrowski, Kent B.; Tannous, Bakhos A.; de Langen, Adrianus J.; Smit, Egbert F.; van den Heuvel, Michel M; Wurdinger, Thomas

    2017-01-01

    Blood-based liquid biopsies, including tumor-educated blood platelets (TEPs), have emerged as promising biomarker sources for non-invasive detection of cancer. Here we demonstrate that particle-swarm optimization (PSO)-enhanced algorithms enable efficient selection of RNA biomarker panels from

  17. Application of silver films with different roughness parameter for septic human serum albumin detection by Surface Enhanced Raman Spectroscopy

    Science.gov (United States)

    Zyubin, A. Y.; Konstantinova, E. I.; Matveeva, K. I.; Slezhkin, V. A.; Samusev, I. G.; Demin, M. V.; Bryukhanov, V. V.

    2018-01-01

    In this paper, the rough silver films parameters investigation, used as media for surface enhancement Raman spectroscopy for health and septic human serum albumin (HSA) study results have been presented. The detection of small concentrations of HSA isolated from blood serum and it main vibrational groups identification has been done.

  18. A Dynamic Enhancement With Background Reduction Algorithm: Overview and Application to Satellite-Based Dust Storm Detection

    Science.gov (United States)

    Miller, Steven D.; Bankert, Richard L.; Solbrig, Jeremy E.; Forsythe, John M.; Noh, Yoo-Jeong; Grasso, Lewis D.

    2017-12-01

    This paper describes a Dynamic Enhancement Background Reduction Algorithm (DEBRA) applicable to multispectral satellite imaging radiometers. DEBRA uses ancillary information about the clear-sky background to reduce false detections of atmospheric parameters in complex scenes. Applied here to the detection of lofted dust, DEBRA enlists a surface emissivity database coupled with a climatological database of surface temperature to approximate the clear-sky equivalent signal for selected infrared-based multispectral dust detection tests. This background allows for suppression of false alarms caused by land surface features while retaining some ability to detect dust above those problematic surfaces. The algorithm is applicable to both day and nighttime observations and enables weighted combinations of dust detection tests. The results are provided quantitatively, as a detection confidence factor [0, 1], but are also readily visualized as enhanced imagery. Utilizing the DEBRA confidence factor as a scaling factor in false color red/green/blue imagery enables depiction of the targeted parameter in the context of the local meteorology and topography. In this way, the method holds utility to both automated clients and human analysts alike. Examples of DEBRA performance from notable dust storms and comparisons against other detection methods and independent observations are presented.

  19. Hydrophobicity-driven self-assembly of protein and silver nanoparticles for protein detection using surface-enhanced Raman scattering.

    Science.gov (United States)

    Kahraman, Mehmet; Balz, Ben N; Wachsmann-Hogiu, Sebastian

    2013-05-21

    Surface-enhanced Raman scattering (SERS) is a promising analytical technique for the detection and characterization of biological molecules and structures. The role of hydrophobic and hydrophilic surfaces in the self-assembly of protein-metallic nanoparticle structures for label-free protein detection is demonstrated. Aggregation is driven by both the hydrophobicity of the surface as well as the charge of the proteins. The best conditions for obtaining a reproducible SERS signal that allows for sensitive, label-free protein detection are provided by the use of hydrophobic surfaces and 16 × 10(11) NPs per mL. A detection limit of approximately 0.5 μg mL(-1) is achieved regardless of the proteins' charge properties and size. The developed method is simple and can be used for reproducible and sensitive detection and characterization of a wide variety of biological molecules and various structures with different sizes and charge status.

  20. Rapid and sensitive detection of synthetic cannabinoids AMB-FUBINACA and α-PVP using surface enhanced Raman scattering (SERS)

    Science.gov (United States)

    Islam, Syed K.; Cheng, Yin Pak; Birke, Ronald L.; Green, Omar; Kubic, Thomas; Lombardi, John R.

    2018-04-01

    The application of surface enhanced Raman scattering (SERS) has been reported as a fast and sensitive analytical method in the trace detection of the two most commonly known synthetic cannabinoids AMB-FUBINACA and alpha-pyrrolidinovalerophenone (α-PVP). FUBINACA and α-PVP are two of the most dangerous synthetic cannabinoids which have been reported to cause numerous deaths in the United States. While instruments such as GC-MS, LC-MS have been traditionally recognized as analytical tools for the detection of these synthetic drugs, SERS has been recently gaining ground in the analysis of these synthetic drugs due to its sensitivity in trace analysis and its effectiveness as a rapid method of detection. This present study shows the limit of detection of a concentration as low as picomolar for AMB-FUBINACA while for α-PVP, the limit of detection is in nanomolar concentration using SERS.

  1. Surface-Enhanced Raman Spectroscopy Study of 4-ATP on Gold Nanoparticles for Basal Cell Carcinoma Fingerprint Detection

    Science.gov (United States)

    Quynh, Luu Manh; Nam, Nguyen Hoang; Kong, K.; Nhung, Nguyen Thi; Notingher, I.; Henini, M.; Luong, Nguyen Hoang

    2016-05-01

    The surface-enhanced Raman signals of 4-aminothiophenol (4-ATP) attached to the surface of colloidal gold nanoparticles with size distribution of 2 to 5 nm were used as a labeling agent to detect basal cell carcinoma (BCC) of the skin. The enhanced Raman band at 1075 cm-1 corresponding to the C-S stretching vibration in 4-ATP was observed during attachment to the surface of the gold nanoparticles. The frequency and intensity of this band did not change when the colloids were conjugated with BerEP4 antibody, which specifically binds to BCC. We show the feasibility of imaging BCC by surface-enhanced Raman spectroscopy, scanning the 1075 cm-1 band to detect the distribution of 4-ATP-coated gold nanoparticles attached to skin tissue ex vivo.

  2. The use of radiometric ore sorting on South African gold mines

    International Nuclear Information System (INIS)

    Boehme, R.C.; Freer, J.S.

    1982-01-01

    This paper refers to the radiometric sorting tests reported during the 7th CMMI Congress, and then describes the photometric and radiometric sorter installations in operation and under construction in South Africa at present. As radiometric sorting of gold ores uses the radiation from the uranium content as a tracer, it is essential that the sortability of the ore should be reliably determined before sorting is adopted. The method of obtaining the important ore characteristics is described, with examples. The possible increase in gold production from a hypothetical plant as a result of sorting is shown

  3. Analysis of differential method for compensating fluctuations in product thickness when radiometric testing

    International Nuclear Information System (INIS)

    Pokrovskij, A.V.; Kvasnitsa, M.S.

    1979-01-01

    Given are the estimates of information capabilities of the differential method for measuring radiation flux in radiation defectoscopy as well as efficiency of application of automatic radiation facilities to control taking into account the statistical regularities of product thickness fluctuations. Dependences of signal to noise ratio on the regularities of product thickness fluctuations have been found and optimization, on this basis, of the design and parameters of processing instrumentation was carried out. It is shown, that with 60-80 mm interval of product thickness fluctuations correlation (welded joints) it is expedient to use two radiation beams with their crossing on a mean product plane. When the interval of correlation of thickness fluctuations is great it is effective to use the geometry of radioscopy with parallel radiation beams. This permits to use only one radiation source without significant reducing the compensation efficiency, that in most cases simplifies the development and application of radiometric systems. Thus the efficiency of applying the differential method for radiation beam detection to compensate product thickness fluctuations is primarily determined by statistical regularities of the given fluctuations. The account of the regularities in the development of the processing instrumentation results in the most complete extraction of useful information, containing in the radiation beams being detected

  4. Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture

    International Nuclear Information System (INIS)

    Brannon, P.; Kiehn, T.E.

    1985-01-01

    The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours and Co., Inc., Wilmington, Del.) was compared with the BACTEC radiometric method (Johnston Laboratories, Inc., Towson, Md.) with 6B and 7D broth media for the recovery of bacteria and yeasts. From 11,000 blood cultures, 1,174 clinically significant organisms were isolated. The Isolator system recovered significantly more total organisms, members of the family Enterobacteriaceae, Staphylococcus spp., and yeasts. The BACTEC system recovered significantly more Pseudomonas spp., Streptococcus spp., and anaerobes. Of the Isolator colony counts, 87% measured less than 11 CFU/ml of blood. Organisms, on an average, were detected the same day from each of the two culture systems. Only 13 of the 975 BACTEC isolates (0.01%) were recovered by subculture of growth-index-negative bottles, and 12 of the 13 were detected in another broth blood culture taken within 24 h. Contaminants were recovered from 4.8% of the Isolator 10 and 2.3% of the BACTEC cultures

  5. Diagnostic value of Gd-EOB-DTPA-enhanced MR cholangiography in non-invasive detection of postoperative bile leakage.

    Science.gov (United States)

    Kul, Melahat; Erden, Ayşe; Düşünceli Atman, Ebru

    2017-04-01

    To assess the diagnostic value of dynamic T 1 weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced MR cholangiography (MRC) for the detection of active bile leaks. A total of 28 patients with suspected biliary leakage who underwent routine T 2 weighted (T2w) MRC and T1w GD-EOB-DTPA-enhanced MRC at our institution from February 2013 to June 2016 were included in this study. The image sets were retrospectively analyzed in consensus by three radiologists. T1w Gd-EOB-DTPA-enhanced MRC findings were correlated with clinical data, follow-up examinations and findings of invasive/surgical procedures. Patients with positive bile leak findings in Gd-EOB-DTPA-enhanced MRC were divided into hepatobiliary phase (HBP) (20-30 min) and delayed phase (DP) (60-390 min) group according to elapsed time between Gd-EOB-DTPA injection and initial bile leak findings in MRC images. These groups were compared in terms of laboratory test results (total bilirubin, liver enzymes) and the presence of bile duct dilatation in T2w MRC images. In each patient, visualization of bile ducts was sufficient in the HBP. The accuracy, sensitivity and specificity of dynamic Gd-EOB-DTPA-enhanced T1w MRC in the detection of biliary leaks were 92.9%, 90.5% and 100%, respectively (p  0.05). Three patients, each of them in DP group, showed normal laboratory test results and bile duct diameters. Dynamic T1w Gd-EOB-DTPA-enhanced MRC is a useful non-invasive diagnostic tool to detect bile leak. Advances in knowledge: Prolonged DP imaging may be required for bile leak detection even if visualization of biliary tree is sufficient in HBP and liver function tests, total bilirubin levels and bile duct diameters are normal.

  6. Noninvasive detection of macrophages in atherosclerotic lesions by computed tomography enhanced with PEGylated gold nanoparticles

    Directory of Open Access Journals (Sweden)

    Qin J

    2014-12-01

    Full Text Available Jinbao Qin,1,* Chen Peng,2,* Binghui Zhao,2,* Kaichuang Ye,1 Fukang Yuan,1 Zhiyou Peng,1 Xinrui Yang,1 Lijia Huang,1 Mier Jiang,1 Qinghua Zhao,3 Guangyu Tang,2 Xinwu Lu1,4 1Department of Vascular Surgery, Shanghai Ninth People’s Hospital Affiliated to Shanghai JiaoTong University, School of Medicine; 2Department of Radiology, Shanghai Tenth People’s Hospital Affiliated to Tongji University, School of Medicine; 3Department of Orthopaedics, Shanghai First People’s Hospital, School of Medicine, Shanghai Jiao Tong University; 4Vascular Center of Shanghai JiaoTong University, Shanghai, People’s Republic of China *These authors contributed equally to this work Abstract: Macrophages are becoming increasingly significant in the progression of atherosclerosis (AS. Molecular imaging of macrophages may improve the detection and characterization of AS. In this study, dendrimer-entrapped gold nanoparticles (Au DENPs with polyethylene glycol (PEG and fluorescein isothiocyanate (FI coatings were designed, tested, and applied as contrast agents for the enhanced computed tomography (CT imaging of macrophages in atherosclerotic lesions. Cell counting kit-8 assay, fluorescence microscopy, silver staining, and transmission electron microscopy revealed that the FI-functionalized Au DENPs are noncytotoxic at high concentrations (3.0 µM and can be efficiently taken up by murine macrophages in vitro. These nanoparticles were administered to apolipoprotein E knockout mice as AS models, which demonstrated that the macrophage burden in atherosclerotic areas can be tracked noninvasively and dynamically three-dimensionally in live animals using micro-CT. Our findings suggest that the designed PEGylated gold nanoparticles are promising biocompatible nanoprobes for the CT imaging of macrophages in atherosclerotic lesions and will provide new insights into the pathophysiology of AS and other concerned inflammatory diseases. Keywords: atherosclerosis, CT, in vivo

  7. Proton detection for signal enhancement in solid-state NMR experiments on mobile species in membrane proteins

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Meaghan E.; Ritz, Emily [University of Guelph, Department of Physics (Canada); Ahmed, Mumdooh A. M. [Suez University, The Department of Physics, Faculty of Science (Egypt); Bamm, Vladimir V.; Harauz, George [University of Guelph, Biophysics Interdepartmental Group (Canada); Brown, Leonid S.; Ladizhansky, Vladimir, E-mail: vladizha@uoguelph.ca [University of Guelph, Department of Physics (Canada)

    2015-12-15

    Direct proton detection is becoming an increasingly popular method for enhancing sensitivity in solid-state nuclear magnetic resonance spectroscopy. Generally, these experiments require extensive deuteration of the protein, fast magic angle spinning (MAS), or a combination of both. Here, we implement direct proton detection to selectively observe the mobile entities in fully-protonated membrane proteins at moderate MAS frequencies. We demonstrate this method on two proteins that exhibit different motional regimes. Myelin basic protein is an intrinsically-disordered, peripherally membrane-associated protein that is highly flexible, whereas Anabaena sensory rhodopsin is composed of seven rigid transmembrane α-helices connected by mobile loop regions. In both cases, we observe narrow proton linewidths and, on average, a 10× increase in sensitivity in 2D insensitive nuclear enhancement of polarization transfer-based HSQC experiments when proton detection is compared to carbon detection. We further show that our proton-detected experiments can be easily extended to three dimensions and used to build complete amino acid systems, including sidechain protons, and obtain inter-residue correlations. Additionally, we detect signals which do not correspond to amino acids, but rather to lipids and/or carbohydrates which interact strongly with membrane proteins.

  8. Determination of uranium and thorium contents using a 14 MeV neutron generator and a radiometric method

    International Nuclear Information System (INIS)

    Casagrande, J.A.

    1981-04-01

    A simple method was developed which can determine uranium and thorium in uranium ores, by 14MeV neutron activation and delayed neutron counting. The process can be used in field laboratories to select samples for processing. The method does not require a previous treatment of the samples and the analysis time is below 5 minutes. The detection limit of the method is about 2 ppm, when the yield of the 14MeV source has a value of 2 X 10 11 neutrons/second, and an optimized delayed neutron counter is used. A radiometric method is used determine separately the thorium content of the sample, and this result is combined with the activation one in order to obtain uranium content. The radiometric method in the counting of the 2,6 MeV gamma rays from 208 Tl using a NaI(Tl) detector. Delayed neutron counting is performed with BF 3 detectors inside a paraffin box. The problem of radioactive equilibrium does not affect thorium determination since the biggest activities of thorium daughters are much smaller than the times involved in the displacements of mineral which can give origin to the radioactive desequilibrium. (Author) [pt

  9. A Data-Driven Monitoring Technique for Enhanced Fall Events Detection

    KAUST Repository

    Zerrouki, Nabil; Harrou, Fouzi; Sun, Ying; Houacine, Amrane

    2016-01-01

    Fall detection is a crucial issue in the health care of seniors. In this work, we propose an innovative method for detecting falls via a simple human body descriptors. The extracted features are discriminative enough to describe human postures

  10. Non-labeling multiplex surface enhanced Raman scattering (SERS) detection of volatile organic compounds (VOCs)

    DEFF Research Database (Denmark)

    Wong, Chi Lok; Dinish, U. S.; Schmidt, Michael Stenbæk

    2014-01-01

    chemical sensing layer for the enrichment of gas molecules on sensor surface. The leaning nano-pillar substrate also showed highly reproducible SERS signal in cyclic VOCs detection, which can reduce the detection cost in practical applications. Further, multiplex SERS detection on different combination...... device for multiplex, specific and highly sensitive detection of complex VOCs samples that can find potential applications in exhaled breath analysis, hazardous gas analysis, homeland security and environmental monitoring....

  11. A UNIFIED APPROACH FOR DETECTION AND PREVENTION OF DDOS ATTACKS USING ENHANCED SUPPORT VECTOR MACHINES AND FILTERING MECHANISMS

    Directory of Open Access Journals (Sweden)

    T. Subbulakshmi

    2014-10-01

    Full Text Available Distributed Denial of Service (DDoS attacks were considered to be a tremendous threat to the current information security infrastructure. During DDoS attack, multiple malicious hosts that are recruited by the attackers launch a coordinated attack against one host or a network victim, which cause denial of service to legitimate users. The existing techniques suffer from more number of false alarms and more human intervention for attack detection. The objective of this paper is to monitor the network online which automatically initiates detection mechanism if there is any suspicious activity and also defense the hosts from being arrived at the network. Both spoofed and non spoofed IP’s are detected in this approach. Non spoofed IP’s are detected using Enhanced Support Vector Machines (ESVM and spoofed IP’s are detected using Hop Count Filtering (HCF mechanism. The detected IP’s are maintained separately to initiate the defense process. The attack strength is calculated using Lanchester Law which initiates the defense mechanism. Based on the calculated attack strength any of the defense schemes such as Rate based limiting or History based IP filtering is automatically initiated to drop the packets from the suspected IP. The integrated online monitoring approach for detection and defense of DDoS attacks is deployed in an experimental testbed. The online approach is found to be obvious in the field of integrated DDoS detection and defense.

  12. A new radiometric instrument designed to measure the parameters of bituminous coal on transport belts

    International Nuclear Information System (INIS)

    Kubicek, P.

    1993-01-01

    A new radiometric instrument developed in Czechoslovakia, for the measurement of ash content of bituminous coal, and for the determination of approximate values of moisture and weight is described. (Author)

  13. Signature modelling and radiometric rendering equations in infrared scene simulation systems

    CSIR Research Space (South Africa)

    Willers, CJ

    2011-09-01

    Full Text Available The development and optimisation of modern infrared systems necessitates the use of simulation systems to create radiometrically realistic representations (e.g. images) of infrared scenes. Such simulation systems are used in signature prediction...

  14. Radiometric-microbiologic assay fo vitamin B-6: analysis of plasma samples

    International Nuclear Information System (INIS)

    Guilarte, T.R.; McIntyre, P.A.

    1981-01-01

    A radiometric microbiologic assay for the analysis of vitamin B-6 in plasma was developed. The method is based on the measurement of 14CO2 generated from the metabolism of DL-l-14C-valine (L-l-14C-valine) by Kloeckera brevis. The assay is specific for the biologically active forms of the vitamin, that is, pyridoxine, pyridoxal and pyridoxamine, and their respective phosphorylated forms. The biologically inert vitamin B-6 metabolite (4-pyridoxic acid) did not generate a response at concentrations tested. The radiometric technique was shown to be sensitive to the 1 nanogram level. Reproducibility and recovery studies gave good results. Fifteen plasma samples were assayed using the radiometric and turbidimetric techniques. The correlation coefficient was r . 0.98. Turbid material or precipitated debris did not interfere with the radiometric microbiologic assay, thus allowing for simplification of assay procedure

  15. MER 1 MARS NAVCAM 3 RADIOMETRIC RDR SCI V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains radiometrically calibrated MER-1 Navcam data. The calibration has removed bias, dark current, and flatfield effects from the raw Navcam data,...

  16. A novel technique with enhanced detection and quantitation of HPV-16 E1- and E2-mediated DNA replication

    International Nuclear Information System (INIS)

    Taylor, Ewan R.; Morgan, Iain M.

    2003-01-01

    Transient DNA replication assays to detect papillomavirus E1/E2-mediated DNA replication have depended upon Southern blotting. This technique is hazardous (radioactive), labour intensive, semiquantitative, and physically limited in the number of samples that can be processed at any one time. We have overcome these problems by developing a real-time PCR protocol for the detection of E1/E2-mediated transient DNA replication. The results demonstrate detection of replication at levels not seen using Southern blotting demonstrating enhanced sensitivity. This technique is also, by definition, highly quantitative. Therefore, the real-time PCR technique is the optimal method for the detection of E1/E2-mediated DNA replication

  17. Microsomal aryl hydrocarbon hydroxylase comparison of the direct, indirect and radiometric assays

    International Nuclear Information System (INIS)

    Denison, M.S.; Murray, M.; Wilkinson, C.F.

    1983-01-01

    The direct fluorometric assay of aryl hydrocarbon hydroxlyase has been compared to the more commonly used indirect fluorometric and radiometric assays. Although rat hepatic microsomal activities measured by the direct assay were consistently higher than those obtained by the other assays, the relative changes in activity following enzyme induction and/or inhibition were similar. The direct assay provides an accurate and rapid measure of aryl hydrocarbon hydroxylase activity and avoids several problems inherent in the indirect and radiometric assays. 2 tables

  18. Choosing of mode and calculation of multiple regression equation parameters in X-ray radiometric analysis

    International Nuclear Information System (INIS)

    Mamikonyan, S.V.; Berezkin, V.V.; Lyubimova, S.V.; Svetajlo, Yu.N.; Shchekin, K.I.

    1978-01-01

    A method to derive multiple regression equations for X-ray radiometric analysis is described. Te method is realized in the form of the REGRA program in an algorithmic language. The subprograms included in the program are describe. In analyzing cement for Mg, Al, Si, Ca and Fe contents as an example, the obtainment of working equations in the course of calculations by the program is shown to simpliy the realization of computing devices in instruments for X-ray radiometric analysis

  19. Radiometric and signal-to-noise ratio properties of multiplex dispersive spectrometry

    International Nuclear Information System (INIS)

    Barducci, Alessandro; Guzzi, Donatella; Lastri, Cinzia; Nardino, Vanni; Marcoionni, Paolo; Pippi, Ivan

    2010-01-01

    Recent theoretical investigations have shown important radiometric disadvantages of interferential multiplexing in Fourier transform spectrometry that apparently can be applied even to coded aperture spectrometers. We have reexamined the methods of noninterferential multiplexing in order to assess their signal-to-noise ratio (SNR) performance, relying on a theoretical modeling of the multiplexed signals. We are able to show that quite similar SNR and radiometric disadvantages affect multiplex dispersive spectrometry. The effect of noise on spectral estimations is discussed.

  20. The perspectives of development of radiometric techniques for welded joints testing

    International Nuclear Information System (INIS)

    Troitskij, V.A.; Dovzhenko, V.N.

    1987-01-01

    The perspectives of development of radiometric techniques in non-destructive testing are presented. The problems of computer tomography, radiometric introscopy, electrorentgenography (xeroradiography) are reviewed. The aspects of application of low-silver detectors are also analysed. The studies on the problems mentioned above will be continued in order to eliminate expensive radiographic films and having in mind making the testing process faster. The design of individual dosemeters is also demonstrated. (author)

  1. Radiometric determination of monoethanolamine with /sup 65/ZnSo/sub 4/

    Energy Technology Data Exchange (ETDEWEB)

    Varadan, R; Sriman Narayanan, S; Rao, V R.S. [Indian Inst. of Tech., Bombay. Dept. of Chemistry

    1984-05-07

    Determination of milligram amounts of monoethanolamine (MEA) with zinc(II) by radiometric titration is described. When MEA is added to a zinc(II) solution containing sulphate ions at 25 degC, a white solid complex is formed. The formation of this complex is employed for the radiometric determination of MEA with /sup 65/Zn. The amount of MEA is directly proportional to the activity of the complex formed. The method is simple, rapid and accurate. 8 refs.

  2. Determination of reliability of express forecasting evaluation of radiometric enriching ability of non-ferrous ores

    International Nuclear Information System (INIS)

    Kirpishchikov, S.P.

    1991-01-01

    Use of the data of nuclear physical methods of sampling and logging enables to improve reliability of evaluation of radiometric enriching ability of ores, as well as to evaluate quantitatively this reliability. This problem may be solved by using some concepts of geostatistics. The presented results enable to conclude, that the data of nuclear-physical methods of sampling and logging can provide high reliability of evaluation of radiometric enriching ability of non-ferrous ores and their geometrization by technological types

  3. Radiometric compensation for cooperative distributed multi-projection system through 2-DOF distributed control.

    Science.gov (United States)

    Tsukamoto, Jun; Iwai, Daisuke; Kashima, Kenji

    2015-11-01

    This paper proposes a novel radiometric compensation technique for cooperative projection system based-on distributed optimization. To achieve high scalability and robustness, we assume cooperative projection environments such that 1. each projector does not have information about other projectors as well as target images, 2. the camera does not have information about the projectors either, while having the target images, and 3. only a broadcast communication from the camera to the projectors is allowed to suppress the data transfer bandwidth. To this end, we first investigate a distributed optimization based feedback mechanism that is suitable for the required decentralized information processing environment. Next, we show that this mechanism works well for still image projection, however not necessary for moving images due to the lack of dynamic responsiveness. To overcome this issue, we propose to implement an additional feedforward mechanism. Such a 2 Degree Of Freedom (2-DOF) control structure is well-known in control engineering community as a typical method to enhance not only disturbance rejection but also reference tracking capability, simultaneously. We theoretically guarantee and experimentally demonstrate that this 2-DOF structure yields the moving image projection accuracy that is overwhelming the best achievable performance only by the distributed optimization mechanisms.

  4. Characterization of the Sonoran desert as a radiometric calibration target for Earth observing sensors

    Science.gov (United States)

    Angal, Amit; Chander, Gyanesh; Xiong, Xiaoxiong; Choi, Tae-young; Wu, Aisheng

    2011-01-01

    To provide highly accurate quantitative measurements of the Earth's surface, a comprehensive calibration and validation of the satellite sensors is required. The NASA Moderate Resolution Imaging Spectroradiometer (MODIS) Characterization Support Team, in collaboration with United States Geological Survey, Earth Resources Observation and Science Center, has previously demonstrated the use of African desert sites to monitor the long-term calibration stability of Terra MODIS and Landsat 7 (L7) Enhanced Thematic Mapper plus (ETM+). The current study focuses on evaluating the suitability of the Sonoran Desert test site for post-launch long-term radiometric calibration as well as cross-calibration purposes. Due to the lack of historical and on-going in situ ground measurements, the Sonoran Desert is not usually used for absolute calibration. An in-depth evaluation (spatial, temporal, and spectral stability) of this site using well calibrated L7 ETM+ measurements and local climatology data has been performed. The Sonoran Desert site produced spatial variability of about 3 to 5% in the reflective solar regions, and the temporal variations of the site after correction for view-geometry impacts were generally around 3%. The results demonstrate that, barring the impacts due to occasional precipitation, the Sonoran Desert site can be effectively used for cross-calibration and long-term stability monitoring of satellite sensors, thus, providing a good test site in the western hemisphere.

  5. A Study on Relative Radiometric Calibration without Calibration Field for YG-25

    Directory of Open Access Journals (Sweden)

    ZHANG Guo

    2017-08-01

    Full Text Available YG-25 is the first agility optical remote sensing satellite of China to acquire the sub-meter imagery of the earth. The side slither calibration technique is an on-orbit maneuver that has been used to flat-field image data acquired over the uniform calibration field. However, imaging to the single uniform calibration field cannot afford to calibrate the full dynamic response range of the sensor and reduces the efficiency. The paper proposes a new relative radiometric calibration method that a 90-degree yaw maneuver is performed over any non-uniform features of the Earth for YG-25. Meanwhile, we use an enhanced side slither image horizontal correction method based on line segment detector(LSDalgorithm to solve the side slither image over-shifted problem.The shifted results are compared with other horizontal correction method. The histogram match algorithm is used to calculate the relative gains of all detectors. The correctness and validity of the proposed method are validated by using the YG-25 on-board side slither data. The results prove that the mean streaking metrics of relative correction images of YG-25 is better 0.07%, the noticeable striping artifact and residual noise are removed, the calibration accuracy of side slither technique based on non-uniform features is superior to life image statistics of sensor's life span.

  6. Multiresolution edge detection using enhanced fuzzy c-means clustering for ultrasound image speckle reduction

    Energy Technology Data Exchange (ETDEWEB)

    Tsantis, Stavros [Department of Medical Physics, School of Medicine, University of Patras, Rion, GR 26504 (Greece); Spiliopoulos, Stavros; Karnabatidis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion, GR 26504 (Greece); Skouroliakou, Aikaterini [Department of Energy Technology Engineering, Technological Education Institute of Athens, Athens 12210 (Greece); Hazle, John D. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Kagadis, George C., E-mail: gkagad@gmail.com, E-mail: George.Kagadis@med.upatras.gr, E-mail: GKagadis@mdanderson.org [Department of Medical Physics, School of Medicine, University of Patras, Rion, GR 26504, Greece and Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2014-07-15

    Purpose: Speckle suppression in ultrasound (US) images of various anatomic structures via a novel speckle noise reduction algorithm. Methods: The proposed algorithm employs an enhanced fuzzy c-means (EFCM) clustering and multiresolution wavelet analysis to distinguish edges from speckle noise in US images. The edge detection procedure involves a coarse-to-fine strategy with spatial and interscale constraints so as to classify wavelet local maxima distribution at different frequency bands. As an outcome, an edge map across scales is derived whereas the wavelet coefficients that correspond to speckle are suppressed in the inverse wavelet transform acquiring the denoised US image. Results: A total of 34 thyroid, liver, and breast US examinations were performed on a Logiq 9 US system. Each of these images was subjected to the proposed EFCM algorithm and, for comparison, to commercial speckle reduction imaging (SRI) software and another well-known denoising approach, Pizurica's method. The quantification of the speckle suppression performance in the selected set of US images was carried out via Speckle Suppression Index (SSI) with results of 0.61, 0.71, and 0.73 for EFCM, SRI, and Pizurica's methods, respectively. Peak signal-to-noise ratios of 35.12, 33.95, and 29.78 and edge preservation indices of 0.94, 0.93, and 0.86 were found for the EFCM, SIR, and Pizurica's method, respectively, demonstrating that the proposed method achieves superior speckle reduction performance and edge preservation properties. Based on two independent radiologists’ qualitative evaluation the proposed method significantly improved image characteristics over standard baseline B mode images, and those processed with the Pizurica's method. Furthermore, it yielded results similar to those for SRI for breast and thyroid images significantly better results than SRI for liver imaging, thus improving diagnostic accuracy in both superficial and in-depth structures. Conclusions: A

  7. Multiresolution edge detection using enhanced fuzzy c-means clustering for ultrasound image speckle reduction

    International Nuclear Information System (INIS)

    Tsantis, Stavros; Spiliopoulos, Stavros; Karnabatidis, Dimitrios; Skouroliakou, Aikaterini; Hazle, John D.; Kagadis, George C.

    2014-01-01

    Purpose: Speckle suppression in ultrasound (US) images of various anatomic structures via a novel speckle noise reduction algorithm. Methods: The proposed algorithm employs an enhanced fuzzy c-means (EFCM) clustering and multiresolution wavelet analysis to distinguish edges from speckle noise in US images. The edge detection procedure involves a coarse-to-fine strategy with spatial and interscale constraints so as to classify wavelet local maxima distribution at different frequency bands. As an outcome, an edge map across scales is derived whereas the wavelet coefficients that correspond to speckle are suppressed in the inverse wavelet transform acquiring the denoised US image. Results: A total of 34 thyroid, liver, and breast US examinations were performed on a Logiq 9 US system. Each of these images was subjected to the proposed EFCM algorithm and, for comparison, to commercial speckle reduction imaging (SRI) software and another well-known denoising approach, Pizurica's method. The quantification of the speckle suppression performance in the selected set of US images was carried out via Speckle Suppression Index (SSI) with results of 0.61, 0.71, and 0.73 for EFCM, SRI, and Pizurica's methods, respectively. Peak signal-to-noise ratios of 35.12, 33.95, and 29.78 and edge preservation indices of 0.94, 0.93, and 0.86 were found for the EFCM, SIR, and Pizurica's method, respectively, demonstrating that the proposed method achieves superior speckle reduction performance and edge preservation properties. Based on two independent radiologists’ qualitative evaluation the proposed method significantly improved image characteristics over standard baseline B mode images, and those processed with the Pizurica's method. Furthermore, it yielded results similar to those for SRI for breast and thyroid images significantly better results than SRI for liver imaging, thus improving diagnostic accuracy in both superficial and in-depth structures. Conclusions: A

  8. Enhanced surveillance strategies for detecting and monitoring chronic wasting disease in free-ranging cervids

    Science.gov (United States)

    Walsh, Daniel P.

    2012-01-01

    The purpose of this document is to provide wildlife management agencies with the foundation upon which they can build scientifically rigorous and cost-effective surveillance and monitoring programs for chronic wasting disease (CWD) or refine their existing programs. The first chapter provides an overview of potential demographic and spatial risk factors of susceptible wildlife populations that may be exploited for CWD surveillance and monitoring. The information contained in this chapter explores historic as well as recent developments in our understanding of CWD disease dynamics. It also contains many literature references for readers who may desire a more thorough review of the topics or CWD in general. The second chapter examines methods for enhancing efforts to detect CWD on the landscape where it is not presently known to exist and focuses on the efficiency and cost-effectiveness of the surveillance program. Specifically, it describes the means of exploiting current knowledge of demographic and spatial risk factors, as described in the first chapter, through a two-stage surveillance scheme that utilizes traditional design-based sampling approaches and novel statistical methods to incorporate information about the attributes of the landscape, environment, populations and individual animals into CWD surveillance activities. By accounting for these attributes, efficiencies can be gained and cost-savings can be realized. The final chapter is unique in relation to the first two chapters. Its focus is on designing programs to monitor CWD once it is discovered within a jurisdiction. Unlike the prior chapters that are more detailed or prescriptive, this chapter by design is considerably more general because providing comprehensive direction for creating monitoring programs for jurisdictions without consideration of their monitoring goals, sociopolitical constraints, or their biological systems, is not possible. Therefore, the authors draw upon their collective

  9. Empirical Radiometric Normalization of Road Points from Terrestrial Mobile Lidar System

    Directory of Open Access Journals (Sweden)

    Tee-Ann Teo

    2015-05-01

    Full Text Available Lidar data provide both geometric and radiometric information. Radiometric information is influenced by sensor and target factors and should be calibrated to obtain consistent energy responses. The radiometric correction of airborne lidar system (ALS converts the amplitude into a backscatter cross-section with physical meaning value by applying a model-driven approach. The radiometric correction of terrestrial mobile lidar system (MLS is a challenging task because it does not completely follow the inverse square range function at near-range. This study proposed a radiometric normalization workflow for MLS using a data-driven approach. The scope of this study is to normalize amplitude of road points for road surface classification, assuming that road points from different scanners or strips should have similar responses in overlapped areas. The normalization parameters for range effect were obtained from crossroads. The experiment showed that the amplitude difference between scanners and strips decreased after radiometric normalization and improved the accuracy of road surface classification.

  10. Enhancing early detection of exotic pests in agricultural and forest ecosystems using an urban-gradient framework.

    Science.gov (United States)

    Colunga-Garcia, Manuel; Magarey, Roger A; Haack, Robert A; Gage, Stuart H; Qi, Jiaquo

    2010-03-01

    Urban areas are hubs of international transport and therefore are major gateways for exotic pests. Applying an urban gradient to analyze this pathway could provide insight into the ecological processes involved in human-mediated invasions. We defined an urban gradient for agricultural and forest ecosystems in the contiguous United States to (1) assess whether ecosystems nearer more urbanized areas were at greater risk of invasion, and (2) apply this knowledge to enhance early detection of exotic pests. We defined the gradient using the tonnage of imported products in adjacent urban areas and their distance to nearby agricultural or forest land. County-level detection reports for 39 exotic agricultural and forest pests of major economic importance were used to characterize invasions along the gradient. We found that counties with more exotic pests were nearer the urban end of the gradient. Assuming that the exotic species we analyzed represent typical invaders, then early detection efforts directed at 21-26% of U.S. agricultural and forest land would likely be able to detect 70% of invaded counties and 90% of the selected species. Applying an urban-gradient framework to current monitoring strategies should enhance early detection efforts of exotic pests, facilitating optimization in allocating resources to areas at greater risk of future invasions.

  11. Detection of Mycoplasma pneumoniae in simulated and true clinical throat swab specimens by nanorod array-surface-enhanced Raman spectroscopy.

    Directory of Open Access Journals (Sweden)

    Suzanne L Hennigan

    Full Text Available The prokaryote Mycoplasma pneumoniae is a major cause of respiratory disease in humans, accounting for 20% of all community-acquired pneumonia and the leading cause of pneumonia in older children and young adults. The limitations of existing options for mycoplasma diagnosis highlight a critical need for a new detection platform with high sensitivity, specificity, and expediency. Here we evaluated silver nanorod arrays (NA as a biosensing platform for detection and differentiation of M. pneumoniae in culture and in spiked and true clinical throat swab samples by surface-enhanced Raman spectroscopy (SERS. Three M. pneumoniae strains were reproducibly differentiated by NA-SERS with 95%-100% specificity and 94-100% sensitivity, and with a lower detection limit exceeding standard PCR. Analysis of throat swab samples spiked with M. pneumoniae yielded detection in a complex, clinically relevant background with >90% accuracy and high sensitivity. In addition, NA-SERS correctly classified with >97% accuracy, ten true clinical throat swab samples previously established by real-time PCR and culture to be positive or negative for M. pneumoniae. Our findings suggest that the unique biochemical specificity of Raman spectroscopy, combined with reproducible spectral enhancement by silver NA, holds great promise as a superior platform for rapid and sensitive detection and identification of M. pneumoniae, with potential for point-of-care application.

  12. Enhancing collaborative intrusion detection networks against insider attacks using supervised intrusion sensitivity-based trust management model

    DEFF Research Database (Denmark)

    Li, Wenjuan; Meng, Weizhi; Kwok, Lam-For

    2017-01-01

    To defend against complex attacks, collaborative intrusion detection networks (CIDNs) have been developed to enhance the detection accuracy, which enable an IDS to collect information and learn experience from others. However, this kind of networks is vulnerable to malicious nodes which are utili......To defend against complex attacks, collaborative intrusion detection networks (CIDNs) have been developed to enhance the detection accuracy, which enable an IDS to collect information and learn experience from others. However, this kind of networks is vulnerable to malicious nodes which...... are utilized by insider attacks (e.g., betrayal attacks). In our previous research, we developed a notion of intrusion sensitivity and identified that it can help improve the detection of insider attacks, whereas it is still a challenge for these nodes to automatically assign the values. In this article, we...... of intrusion sensitivity based on expert knowledge. In the evaluation, we compare the performance of three different supervised classifiers in assigning sensitivity values and investigate our trust model under different attack scenarios and in a real wireless sensor network. Experimental results indicate...

  13. Comparative study of protoporphyrin IX fluorescence image enhancement methods to improve an optical imaging system for oral cancer detection

    Science.gov (United States)

    Jiang, Ching-Fen; Wang, Chih-Yu; Chiang, Chun-Ping

    2011-07-01

    Optoelectronics techniques to induce protoporphyrin IX fluorescence with topically applied 5-aminolevulinic acid on the oral mucosa have been developed to noninvasively detect oral cancer. Fluorescence imaging enables wide-area screening for oral premalignancy, but the lack of an adequate fluorescence enhancement method restricts the clinical imaging application of these techniques. This study aimed to develop a reliable fluorescence enhancement method to improve PpIX fluorescence imaging systems for oral cancer detection. Three contrast features, red-green-blue reflectance difference, R/B ratio, and R/G ratio, were developed first based on the optical properties of the fluorescence images. A comparative study was then carried out with one negative control and four biopsy confirmed clinical cases to validate the optimal image processing method for the detection of the distribution of malignancy. The results showed the superiority of the R/G ratio in terms of yielding a better contrast between normal and neoplastic tissue, and this method was less prone to errors in detection. Quantitative comparison with the clinical diagnoses in the four neoplastic cases showed that the regions of premalignancy obtained using the proposed method accorded with the expert's determination, suggesting the potential clinical application of this method for the detection of oral cancer.

  14. Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI

    International Nuclear Information System (INIS)

    Giesel, F.L.; Kratochwil, C.; Mehndiratta, A.; Wulfert, S.; Moltz, J.H.; Zechmann, C.M.; Kauczor, H.U.; Haberkorn, U.; Ley, S.

    2012-01-01

    Purpose: We evaluated the rate of successful characterization of gastroenteropancreatic neuroendocrine tumors (NETs) present with an increased somatostatin receptor, comparing CE-CT with CE-MRI, each in correlation with DOTATOC-PET. Methods and materials: 8 patients with GEP-NET were imaged using CE-MRI (Gd-EOB-DTPA), CE-CT (Imeron 400) and DOTATOC-PET. Contrast-enhancement of normal liver-tissue and metastasis was quantified with ROI-technique. Tumor delineation was assessed with visual-score in blind-read-analysis by two experienced radiologists. Results: Out of 40 liver metastases in patients with NETs, all were detected by CE-MRI and the lesion extent could be adequately assessed, whereas CT failed to detect 20% of all metastases. The blind-read-score of CT in arterial and portal phase was median −0.65 and −1.4, respectively, and 2.7 for delayed-MRI. The quantitative ROI-analysis presented an improved contrast-enhancement-ratio with a median of 1.2, 1.6 and 3.3 for CE-CT arterial, portal-phase and delayed-MRI respectively. Conclusion: Late CE-MRI was superior to CE-CT in providing additionally morphologic characterization and exact lesion extension of hepatic metastases from neuroendocrine tumor detected with DOTATOC-PET. Therefore, late enhanced Gd-EOB-DTPA-MRI seems to be the adequate imaging modality for combination with DOTATOC-PET to provide complementary (macroscopic and molecular) tumor characterization in hepatic metastasized NETs

  15. Design, manufacture, and calibration of infrared radiometric blackbody sources

    International Nuclear Information System (INIS)

    Byrd, D.A.; Michaud, F.D.; Bender, S.C.

    1996-04-01

    A Radiometric Calibration Station (RCS) is being assembled at the Los Alamos National Laboratories (LANL) which will allow for calibration of sensors with detector arrays having spectral capability from about 0.4-15 μm. The configuration of the LANL RCS. Two blackbody sources have been designed to cover the spectral range from about 3-15 μm, operating at temperatures ranging from about 180-350 K within a vacuum environment. The sources are designed to present a uniform spectral radiance over a large area to the sensor unit under test. The thermal uniformity requirement of the blackbody cavities has been one of the key factors of the design, requiring less than 50 mK variation over the entire blackbody surface to attain effective emissivity values of about 0.999. Once the two units are built and verified to the level of about 100 mK at LANL, they will be sent to the National Institute of Standards and Technology (NIST), where at least a factor of two improvement will be calibrated into the blackbody control system. The physical size of these assemblies will require modifications of the existing NIST Low Background Infrared (LBIR) Facility. LANL has constructed a bolt-on addition to the LBIR facility that will allow calibration of our large aperture sources. Methodology for attaining the two blackbody sources at calibrated levels of performance equivalent to present state of the art will be explained in the following

  16. Radiometric analyses of floodplain sediments at the Savannah River Plant

    International Nuclear Information System (INIS)

    Lower, M.W.

    1987-09-01

    A Comprehensive Cooling Water Study to assess the effects of reactor cooling water discharges and related reactor area liquid releases to onsite streams and the nearby Savannah River has been completed at the US Department of Energy's Savannah River Plant (SRP). Extensive radiometric analyses of man-made and naturally occurring gamma-emitting radionuclides were measured in floodplain sediment cores extracted from onsite surface streams at SRP and from the Savannah River. Gamma spectrometric analyses indicate that reactor operations contribute to floodplain radioactivity levels slightly higher than levels associated with global fallout. In locations historically unaffected by radioactive releases from SRP operations, Cs-137 concentrations were found at background and fallout levels of about 1 pCi/g. In onsite streams that provided a receptor for liquid radioactive releases from production reactor areas, volume-weighted Cs-137 concentrations ranged by core from background levels to 55 pCi/g. Savannah River sediments contained background and atmospheric fallout levels of Cs-137 only. 2 refs., 5 figs

  17. JPSS-1 VIIRS Pre-Launch Radiometric Performance

    Science.gov (United States)

    Oudrari, Hassan; Mcintire, Jeffrey; Xiong, Xiaoxiong; Butler, James; Ji, Qiang; Schwarting, Tom; Zeng, Jinan

    2015-01-01

    The first Joint Polar Satellite System (JPSS-1 or J1) mission is scheduled to launch in January 2017, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the J1 spacecraft completed its sensor level performance testing in December 2014. VIIRS instrument is expected to provide valuable information about the Earth environment and properties on a daily basis, using a wide-swath (3,040 km) cross-track scanning radiometer. The design covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands, from 0.412 m to 12.01 m, and has spatial resolutions of 370 m and 740 m at nadir for imaging and moderate bands, respectively. This paper will provide an overview of pre-launch J1 VIIRS performance testing and methodologies, describing the at-launch baseline radiometric performance as well as the metrics needed to calibrate the instrument once on orbit. Key sensor performance metrics include the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field response, and stray light rejection. A set of performance metrics generated during the pre-launch testing program will be compared to the sensor requirements and to SNPP VIIRS pre-launch performance.

  18. Iodine sorption of bentonite - radiometric and polarographic study

    International Nuclear Information System (INIS)

    Konirova, R.; Vinsova, H.; Koudelkova, M.; Ernestova, M.; Jedinakova-Krizova, V.

    2003-01-01

    The experiments focused on kinetics of iodine retardation on bentonite, influence of aqueous phase pH, buffering properties of bentonite, etc. were carried out by batch method. Distribution coefficient KD was the criterion applied for evaluation of iodine interaction with solid phase. High sorption potential of bentonite to cationic forms of various radionuclides, resulting from relatively high cation exchange capacity, is generally known. On the other hand the inorganic anions are not adsorbed strongly to mineral surface of clays thus uptake of iodine (occurring mainly at iodide (I - ) or iodate (IO 3 - ) form under oxoic conditions) is limited. The distribution coefficients of iodine anions' sorption on bentonite R reach order of magnitude 10 -1 mL/g. In order to increase the sorption capacity of the solid phase, several additives were added to bentonite. Most of them didn't provide satisfactory results except of the addition of activated carbon, which has high surface area. Electromigration and polarographic methods were used for investigation of the redox state of iodine in aqueous phase and determination of KD values as well. Acquired results were compared with data obtained by radiometric measurements. (authors)

  19. Study and characterization of porous germanium for radiometric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Akkari, E.; Benachour, Z.; Touayar, O.; Benbrahim, J. [Activites de Recherche, Metrologie des Rayonnements, Institut National des Sciences Appliquees et de Technologie, INSAT, Tunis (Tunisia); Aouida, S.; Bessais, B. [Laboratoire de Nanomateriaux et des Systemes de l' Energie, LaNSE, Centre de Recherche et des Technologies de l' Energie, CRTEn, Hammam-Lif (Tunisia)

    2009-07-15

    The aim of this article is to study and realize a new detector based on a porous germanium (pGe) photodiode to be used as a standard for radiometric measurement in the wavelength region between 800 nm and 1700 nm. We present the development and characterization of a porous structure realized on a single-crystal substrate of p-type germanium (Ga doped) and of crystallographic orientation (100). The obtained structure allows, on the one hand, to trap the incident radiation, and on the other hand, to minimize the fluctuations of the front-face reflection coefficient of the photodiode. The first studies thus made show that it is possible to optimize, respectively, the electrical current density and the electrochemical operation time necessary for obtaining exploitable porous structures. The obtained results show that for 50 mA/cm{sup 2} and 5 min as operational parameters, we obtain a textured aspect of the porous samples that present a pyramidal form. The reflectivity study of the front surface shows a constant value of around 38% in a spectral range between 800 nm and 1700 nm approximately. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  20. Effects of integration time on in-water radiometric profiles.

    Science.gov (United States)

    D'Alimonte, Davide; Zibordi, Giuseppe; Kajiyama, Tamito

    2018-03-05

    This work investigates the effects of integration time on in-water downward irradiance E d , upward irradiance E u and upwelling radiance L u profile data acquired with free-fall hyperspectral systems. Analyzed quantities are the subsurface value and the diffuse attenuation coefficient derived by applying linear and non-linear regression schemes. Case studies include oligotrophic waters (Case-1), as well as waters dominated by Colored Dissolved Organic Matter (CDOM) and Non-Algal Particles (NAP). Assuming a 24-bit digitization, measurements resulting from the accumulation of photons over integration times varying between 8 and 2048ms are evaluated at depths corresponding to: 1) the beginning of each integration interval (Fst); 2) the end of each integration interval (Lst); 3) the averages of Fst and Lst values (Avg); and finally 4) the values weighted accounting for the diffuse attenuation coefficient of water (Wgt). Statistical figures show that the effects of integration time can bias results well above 5% as a function of the depth definition. Results indicate the validity of the Wgt depth definition and the fair applicability of the Avg one. Instead, both the Fst and Lst depths should not be adopted since they may introduce pronounced biases in E u and L u regression products for highly absorbing waters. Finally, the study reconfirms the relevance of combining multiple radiometric casts into a single profile to increase precision of regression products.

  1. Radiometric determination of uniformity of putting paraffin on textile threads

    International Nuclear Information System (INIS)

    Ridel', Z.; Kherrmann, Eh.; Shefer, I.; Tseiner, A.

    1979-01-01

    To improve processing of the natural and synthetic fiber threads on stocking-frames, they are treated by paraffin. Paraffin is applied in the amounts nearly equal to 0.1 -1.0 g for 10 4 m of the thread's length. To determine amount of paraffin on thread and to determine uniformity if its application, a radiometric method has been developed. As a radioactive label, didocilephosphate of rare earths was used. This compound has good solubility in hydrocarbons and does not change physical properties of paraffin in the investigated field of its application as well as its concentration. It is possible to add to paraffin this radioactive label or a non-active label with subsequent its activation. Amount of paraffin, applied on a thread is determined by means of measurement of activity of thread samples of different length. Information about uniformity of paraffin application on thread have been obtained by means of autoradiography. It has been found that paraffin in mainly applied on the thread's bulges [ru

  2. Contrast-enhanced ultrasonography and spiral computed tomography in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Sandro; Ghittoni, Giorgia; Ravetta, Valentina; Torello Viera, Francesca; Rosa, Laura [Policlinico ' S. Matteo' Foundation, IRCCS, VI Department of Internal Medicine and Interventional Ultrasonography, Pavia (Italy); Serassi, Martina; Scabini, Mara; Vercelli, Alessandro; Calliada, Fabrizio [IRCCS Policlinico ' S. Matteo' , Department of Radiology, P.le Golgi n. 19, Pavia (Italy); Tinelli, Carmine [Biometrics Unit, IRCCS Policlinico ' S. Matteo' , Pavia (Italy); Dal Bello, Barbara [IRCCS Policlinico ' S. Matteo' , Department of Human Pathology, Pavia (Italy); Burns, Peter N. [University of Toronto, Department of Medical Biophysics, Toronto, ON (Canada); Imaging Research S660, Sunnybrook Health Science Centre, Toronto, ON (Canada)

    2008-08-15

    The aim was to compare the performances of contrast-enhanced (CE) ultrasonography (US) and spiral computed tomography (CT) in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma (HCC). We studied 50 patients with HCC who had biopsy-proven portal vein thrombi that had been detected with US and color Doppler US. Thirteen of the thrombi involved the main portal trunk and 37 the segmental branches. CEUS and CT were performed within a week of thrombus biopsies. For each imaging technique, diagnoses of thrombosis (present/absent) and thrombus nature (malignancy/benignancy) were made by experienced readers under blinded conditions and compared with pathological findings to determine accuracy rates for thrombus detection and characterization. Forty-four of the 50 thrombi were pathologically diagnosed as malignant and the remaining six were benign. CEUS detected 50/50 (100%) thrombi and correctly characterized 49/50 (98%). CT detected 34/50 (68%) thrombi and correctly characterized 23 of these 34 (68%). CEUS outperformed CT in terms of both thrombus detection (P < 0.0001) and characterization (P = 0.0001). CEUS appears to be significantly superior to CT for detection and characterization of portal vein thrombosis complicating HCC, and it should be considered in the staging of these tumors. (orig.)

  3. A new automated quantification algorithm for the detection and evaluation of focal liver lesions with contrast-enhanced ultrasound.

    Science.gov (United States)

    Gatos, Ilias; Tsantis, Stavros; Spiliopoulos, Stavros; Skouroliakou, Aikaterini; Theotokas, Ioannis; Zoumpoulis, Pavlos; Hazle, John D; Kagadis, George C

    2015-07-01

    Detect and classify focal liver lesions (FLLs) from contrast-enhanced ultrasound (CEUS) imaging by means of an automated quantification algorithm. The proposed algorithm employs a sophisticated segmentation method to detect and contour focal lesions from 52 CEUS video sequences (30 benign and 22 malignant). Lesion detection involves wavelet transform zero crossings utilization as an initialization step to the Markov random field model toward the lesion contour extraction. After FLL detection across frames, time intensity curve (TIC) is computed which provides the contrast agents' behavior at all vascular phases with respect to adjacent parenchyma for each patient. From each TIC, eight features were automatically calculated and employed into the support vector machines (SVMs) classification algorithm in the design of the image analysis model. With regard to FLLs detection accuracy, all lesions detected had an average overlap value of 0.89 ± 0.16 with manual segmentations for all CEUS frame-subsets included in the study. Highest classification accuracy from the SVM model was 90.3%, misdiagnosing three benign and two malignant FLLs with sensitivity and specificity values of 93.1% and 86.9%, respectively. The proposed quantification system that employs FLLs detection and classification algorithms may be of value to physicians as a second opinion tool for avoiding unnecessary invasive procedures.

  4. A Data-Driven Monitoring Technique for Enhanced Fall Events Detection

    KAUST Repository

    Zerrouki, Nabil

    2016-07-26

    Fall detection is a crucial issue in the health care of seniors. In this work, we propose an innovative method for detecting falls via a simple human body descriptors. The extracted features are discriminative enough to describe human postures and not too computationally complex to allow a fast processing. The fall detection is addressed as a statistical anomaly detection problem. The proposed approach combines modeling using principal component analysis modeling with the exponentially weighted moving average (EWMA) monitoring chart. The EWMA scheme is applied on the ignored principal components to detect the presence of falls. Using two different fall detection datasets, URFD and FDD, we have demonstrated the greater sensitivity and effectiveness of the developed method over the conventional PCA-based methods.

  5. Contrast-enhanced ultrasound vs multidetector-computed tomography for detecting liver metastases in colorectal cancer: a prospective, blinded, patient-by-patient analysis

    DEFF Research Database (Denmark)

    Rafaelsen, S R; Jakobsen, A

    2011-01-01

    This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer.......This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer....

  6. Determination of the sun area in sky camera images using radiometric data

    International Nuclear Information System (INIS)

    Alonso, J.; Batlles, F.J.; Villarroel, C.; Ayala, Rosa; Burgaleta, J.I.

    2014-01-01

    Highlights: • We have developed a model for the determination of solar area on sky camera imagery. • An estimation of direct normal irradiance is given for cloudless sky. • The presented model resolves the problem of saturation of pixels in the solar area. • The model allows to identify clouds in the solar area of sky camera imagery. • Developed model has an 92% of agreement between processed and observed images. - Abstract: Due to the increasing development and expansion of solar power plants, it is necessary to have complete and absolute knowledge of all factors and occurrences that can affect the dynamics and quality of their production. The importance of clouds in the attenuation of solar radiation is a transcendental and decisive factor in the incident energy from the sun. Detecting clouds with sky cameras is a very problematic issue. The captured solar area in the images exhibits a pronounced saturation of pixels as a consequence of sunlight penetration and the appearance of various atmospheric features. The present article reports a methodology based on radiometric data that is used to determine the causes of saturation in the solar zone and its vicinity on images from a TSI-880 model sky camera. The correct method identifies the presence or absence of clouds in the saturated zone with 92% success

  7. Analysis of hyperspectral field radiometric data for monitoring nitrogen concentration in rice crops

    Science.gov (United States)

    Stroppiana, D.; Boschetti, M.; Confalonieri, R.; Bocchi, S.; Brivio, P. A.

    2005-10-01

    Monitoring crop conditions and assessing nutrition requirements is fundamental for implementing sustainable agriculture. Rational nitrogen fertilization is of particular importance in rice crops in order to guarantee high production levels while minimising the impact on the environment. In fact, the typical flooded condition of rice fields can be a significant source of greenhouse gasses. Information on plant nitrogen concentration can be used, coupled with information about the phenological stage, to plan strategies for a rational and spatially differentiated fertilization schedule. A field experiment was carried out in a rice field Northern Italy, in order to evaluate the potential of field radiometric measurements for the prediction of rice nitrogen concentration. The results indicate that rice reflectance is influenced by nitrogen supply at certain wavelengths although N concentration cannot be accurately predicted based on the reflectance measured at a given wavelength. Regression analysis highlighted that the visible region of the spectrum is most sensitive to plant nitrogen concentration when reflectance measures are combined into a spectral index. An automated procedure allowed the analysis of all the possible combinations into a Normalized Difference Index (NDI) of the narrow spectral bands derived by spectral resampling of field measurements. The derived index appeared to be least influenced by plant biomass and Leaf Area Index (LAI) providing a useful approach to detect rice nutritional status. The validation of the regressive model showed that the model is able to predict rice N concentration (R2=0.55 [p<0.01] RRMSE=29.4; modelling efficiency close to the optimum value).

  8. Evaluation of a radiometric method for pyrazinamide susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Tarrand, J.J.; Spicer, A.D.; Groeschel, D.H.

    1986-01-01

    Pyrazinamide susceptibility testing of Mycobacterium tuberculosis requires an acid environment. By controlling the method of acidification and the quality and quantity of the inoculum, the test can be performed with the BACTEC radiometric system (Johnston Laboratories, Towson, Md.). We acidified BACTEC 7H12 medium with buffered phosphoric acid and adjusted the test inoculum to 1/10 of that usually employed in BACTEC protocols; after 5 days of growth we correctly identified 36 of 36 strains susceptible to 50 micrograms of pyrazinamide per ml. All 18 resistant strains were classified as pyrazinamide resistant. (Susceptibility or resistance had been determined by standard plate assays.) The test was able to detect small resistant populations in artificial mixtures of 1 or 2% resistant bacteria with a susceptible strain (10 mixtures each). We tested 70 M. tuberculosis strains in acidified BACTEC 7H12 medium and by the plate dilution test at pH 5.5. All strains grew in the BACTEC medium, but three strains failed to grow on plates and were not tested further; the results of both methods agreed for the remaining strains

  9. Enhancing the Statistical Filtering Scheme to Detect False Negative Attacks in Sensor Networks

    Directory of Open Access Journals (Sweden)

    Muhammad Akram

    2017-06-01

    Full Text Available In this paper, we present a technique that detects both false positive and false negative attacks in statistical filtering-based wireless sensor networks. In statistical filtering scheme, legitimate reports are repeatedly verified en route before they reach the base station, which causes heavy energy consumption. While the original statistical filtering scheme detects only false reports, our proposed method promises to detect both attacks.

  10. A dual amplification strategy for DNA detection combining bio-barcode assay and metal-enhanced fluorescence modality.

    Science.gov (United States)

    Zhou, Zhenpeng; Li, Tian; Huang, Hongduan; Chen, Yang; Liu, Feng; Huang, Chengzhi; Li, Na

    2014-11-11

    Silver-enhanced fluorescence was coupled with a bio-barcode assay to facilitate a dual amplification assay to demonstrate a non-enzymatic approach for simple and sensitive detection of DNA. In the assay design, magnetic nanoparticles seeded with silver nanoparticles were modified with the capture DNA, and silver nanoparticles were modified with the binding of ssDNA and the fluorescently labeled barcode dsDNA. Upon introduction of the target DNA, a sandwich structure was formed because of the hybridization reaction. By simple magnetic separation, silver-enhanced fluorescence of barcode DNAs could be readily measured without the need of a further step to liberate barcode DNAs from silver nanoparticles, endowing the method with simplicity and high sensitivity with a detection limit of 1 pM.

  11. Highly selective and sensitive detection of Cu2+ with lysine enhancing bovine serum albumin modified-carbon dots fluorescent probe.

    Science.gov (United States)

    Liu, Jia-Ming; Lin, Li-ping; Wang, Xin-Xing; Lin, Shao-Qin; Cai, Wen-Lian; Zhang, Li-Hong; Zheng, Zhi-Yong

    2012-06-07

    Based on the ability of lysine (Lys) to enhance the fluorescence intensity of bovine serum albumin modified-carbon dots (CDs-BSA) to decrease surface defects and quench fluorescence of the CDs-BSA-Lys system in the presence of Cu(2+) under conditions of phosphate buffer (PBS, pH = 5.0) at 45 °C for 10 min, a sensitive Lys enhancing CDs-BSA fluorescent probe was designed. The environment-friendly, simple, rapid, selective and sensitive fluorescent probe has been utilized to detect Cu(2+) in hair and tap water samples and it achieved consistent results with those obtained by inductively coupled plasma mass spectroscopy (ICP-MS). The mechanism of the proposed assay for the detection of Cu(2+) is discussed.

  12. Combined use of vancomycin-modified Ag-coated magnetic nanoparticles and secondary enhanced nanoparticles for rapid surface-enhanced Raman scattering detection of bacteria.

    Science.gov (United States)

    Wang, Chongwen; Gu, Bing; Liu, Qiqi; Pang, Yuanfeng; Xiao, Rui; Wang, Shengqi

    2018-01-01

    Pathogenic bacteria have always been a significant threat to human health. The detection of pathogens needs to be rapid, accurate, and convenient. We present a sensitive surface-enhanced Raman scattering (SERS) biosensor based on the combination of vancomycin-modified Ag-coated magnetic nanoparticles (Fe 3 O 4 @Ag-Van MNPs) and Au@Ag nanoparticles (NPs) that can effectively capture and discriminate bacterial pathogens from solution. The high-performance Fe 3 O 4 @Ag MNPs were modified with vancomycin and used as bacteria capturer for magnetic separation and enrichment. The modified MNPS were found to exhibit strong affinity with a broad range of Gram-positive and Gram-negative bacteria. After separating and rinsing bacteria, Fe 3 O 4 @Ag-Van MNPs and Au@Ag NPs were synergistically used to construct a very large number of hot spots on bacteria cells, leading to ultrasensitive SERS detection. The dominant merits of our dual enhanced strategy included high bacterial-capture efficiency (>65%) within a wide pH range (pH 3.0-11.0), a short assay time (<30 min), and a low detection limit (5×10 2 cells/mL). Moreover, the spiked tests show that this method is still valid in milk and blood samples. Owing to these capabilities, the combined system enabled the sensitive and specific discrimination of different pathogens in complex solution, as verified by its detection of Gram-positive bacterium Escherichia coli , Gram-positive bacterium Staphylococcus aureus , and methicillin-resistant S. aureus . This method has great potential for field applications in food safety, environmental monitoring, and infectious disease diagnosis.

  13. Protein assisted fluorescence enhancement of a dansyl containing fluorescent reagent: detection of Hg+ ion in aqueous medium.

    Science.gov (United States)

    Srivastava, Priyanka; Shahid, Mohammad; Misra, Arvind

    2011-07-21

    Intramolecular charge transfer (ICT) based fluorescent reagents containing a dansyl fluorophore have been synthesized and characterized. The reagent 1 and its complex, 1+Hg(2+) in sodium acetate buffer (pH 6.7) revealed considerable fluorescence enhancement (switched-on) in the presence of bovine serum albumin (BSA) with 10 ppb detection sensitivity. (1)H NMR spectral analysis suggests complexation between 1 and Hg(2+) ion involving the N,N-dimethylamino and carboxylic functions.

  14. Surface-enhanced Raman detection of RNA and DNA bases following flow-injection analysis or HPLC separation

    Science.gov (United States)

    Cotton, Therese M.; Sheng, Rong-Sheng; Ni, Fan

    1990-11-01

    The goal of this study is to develop Surface-enhanced Raman scattering (SERS) detection methods for flow injection analysis (FIA) and high performance liquid chromatography (HPLC). Nucleic acid bases have been chosen for analysis because of their importance in life processes. The advantages to the use of SERS-based detection include its sensitivity, specificity and versatility. With the development of improved methodology, the detection limits should be comparable to UV spectroscopy. However, the specificity is considerably superior to that obtained with electronic spectroscopy in that the Raman spectrum provides a molecular fingerprint of the individual analytes. Raman spectroscopy is very versatile: aqueous samples, gases and solids can be analyzed with equal facility. The results presented here demonstrate that SERS can be used as a detection method for both FIA and HPLC detection. In the following experiments Ag sols have been used as the active substrate. The effect of various parameters such as temperature, pH, flow rate, and the nature of the interface between the HPLC system and the Raman spectrometer have been examined. One of the most significant findings is that the temperature of the Ag sol/HPLC effluent mixture has a dramatic effect on the SERS intensities. This effect is a result of increased colloid aggregation at higher temperatures. Aggregation is known to produce greater enhancement in SERS and proceeds much more rapidly at elevated temperatures. An increase in the temperature of the Ag sol enables SERS detection under flowing conditions and in real time. This is a substantial improvement over many of the previous attempts to interface SERS detection to FIA or HPLC. In most of the previous studies, it was necessary to stop the flow as the analyte eluted from the chromatogram and measure the SERS spectra under static conditions.

  15. Wavelength modulated surface enhanced (resonance) Raman scattering for background-free detection.

    Science.gov (United States)

    Praveen, Bavishna B; Steuwe, Christian; Mazilu, Michael; Dholakia, Kishan; Mahajan, Sumeet

    2013-05-21

    Spectra in surface-enhanced Raman scattering (SERS) are always accompanied by a continuum emission called the 'background' which complicates analysis and is especially problematic for quantification and automation. Here, we implement a wavelength modulation technique to eliminate the background in SERS and its resonant version, surface-enhanced resonance Raman scattering (SERRS). This is demonstrated on various nanostructured substrates used for SER(R)S. An enhancement in the signal to noise ratio for the Raman bands of the probe molecules is also observed. This technique helps to improve the analytical ability of SERS by alleviating the problem due to the accompanying background and thus making observations substrate independent.

  16. Detection of microcalcifications in television-enhanced nonmagnified screen-film mammograms compared with matching magnification unenhanced mammograms

    International Nuclear Information System (INIS)

    Kimme-Smith, C.; Gormley, L.S.; Gold, R.H.; Bassett, L.W.

    1988-01-01

    The object of this investigation was to determine which imaging method was associated with greater accuracy in the interpretation of breast microcalcifications: 1.5X to 2.0X magnification with a microfocal spot or Damon DETECT-enhanced mammograms. The authors' test series consisted of matched pairs of images of 31 breasts, each containing a cluster of microcalcifications within a biopsy-proved benign (N = 21) or malignant (N =10) lesion. Three experienced mammographers and three senior radiology residents with 2 weeks of training in mammography interpreted the calcifications. On the basis of receiver operating characteristic analysis, the authors conclude that (1) inexperienced mammographers should not use television image enhancement alone to evaluate microcalcifications and (2) television-enhanced mammograms are not a substitute for microfocal spot magnification mammograms

  17. Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciation

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Sturup, Stefan

    1994-01-01

    Addition of carbon as methanol or ammonium carbonate to the aqueous analyte solutions in combination with increased plasma power input enhanced the inductively coupled plasma mass spectrometry (ICP-MS) signal intensities of arsenic and selenium. In the presence of the optimum 3% v/v methanol...... (noise) was not increased. Therefore, the observed increase in analyte sensitivity led to a similar increase in signal-to-noise ratio. The addition of carbon as ammonium carbonate enhanced the arsenic signal by a similar factor but caused severe contamination of the ICP-MS instrument by carbon. In the 3....../nebulization efficiency. It is proposed that an increased population of carbon ions or carbon-containing ions in the plasma facilitates a more complete ionization of analytes lower in ionization energy than carbon itself. The enhanced detection power for arsenic was applied to arsenic speciation by high...

  18. Comparison between immediate and delayed imaging after gadolinium chelate injection for detecting enhanced lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Alizadeh, A.; Roudbari, A.; Heidarzadeh, A.; Kouhsari, M.

    2010-01-01

    Magnetic resonance imaging is a noninvasive and valuable method in the diagnosis of Multiple Sclerosis. Compared with other modalities, the sensitivity of Magnetic resonance imaging for detection of the lesion increases using magnetization transfer and delayed imaging. Our aim was to compare the two methods in detecting Multiple Sclerosis lesions. Patients and Methods: In this double-blind clinical trial, twenty-one patients with the definite diagnosis of Multiple Sclerosis referred to Poursina Hospital, Rasht were included. Two radiologists evaluated all the images. First, images without contrast were conducted, then 0.1 mmol/kg contrast material (Dotarem, single dose) was injected and after 30 minutes, T1W and magnetization transfer images were obtained. Seventy-two hours later, T1W images were obtained immediately after injection of 0.2 mmol/kg contrast material (double dose). The data were analyzed using Fisher's and McNemar tests by SPSS for Windows. Results: Delayed magnetization transfer showed 44 enhanced lesions using magnetization transfer (69.84%) and 29 lesions using T1 (46.03%). In addition, the number of enhanced lesions in the delayed method were significantly more than those in the immediate method (p value=0.003). Conclusion: The use of single dose in combination with magnetization transfer and delayed images after 20-30 minutes enables us to detect more enhanced lesions.

  19. Gadoxetic acid-enhanced MRI and diffusion-weighted imaging for the detection of colorectal liver metastases after neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Yu, Mi Hye; Lee, Jeong Min; Han, Joon Koo; Choi, Byung-Ihn; Hur, Bo Yun; Kim, Tae-You; Jeong, Seung-Yong; Yi, Nam-Joon; Suh, Kyung-Suk

    2015-01-01

    To investigate the diagnostic performance of gadoxetic acid-enhanced MRI including diffusion-weighted imaging (DWI) for the detection of colorectal liver metastases (CRLMs) after neoadjuvant chemotherapy (NAC). Our study population comprised 77 patients with 140 CRLMs who underwent gadoxetic acid-enhanced MRI within 1 month prior to surgery: group A (without NAC, n = 38) and group B (with NAC, n = 39). Two radiologists independently assessed all MR images and graded their diagnostic confidence for CRLM on a 5-point scale. Diagnostic accuracy, sensitivity and positive predictive values (PPV) were calculated and compared between the two groups. Diagnostic accuracy of gadoxetic acid-enhanced MRI in group B was slightly lower than in group A, but a statistically significant difference was not observed (observer 1: A z , 0.926 in group A, 0.905 in group B; observer 2: A z , 0.944 in group A, 0.885 in group B; p > 0.05). Sensitivity and PPV of group B were comparable to those of group A (observer 1: sensitivity = 93.5 % vs. 93.6 %, PPV = 95.1 % vs. 86.9 %; observer 2: sensitivity = 96.8 % vs. 91.0 %; PPV = 90.0 % vs. 89.7 %; all p > 0.05). Gadoxetic acid-enhanced MRI including DWI provided good diagnostic performance with high sensitivity (>90 %) for the detection of CRLMs, regardless of the influence of NAC. (orig.)

  20. Multifunctional silver nanoparticle-doped silica for solid-phase extraction and surface-enhanced Raman scattering detection

    Science.gov (United States)

    Markina, Natalia E.; Markin, Alexey V.; Zakharevich, Andrey M.; Gorin, Dmitry A.; Rusanova, Tatiana Yu.; Goryacheva, Irina Yu.

    2016-12-01

    Multifunctional silica gel with embedded silver nanoparticles (SiO2-AgNP) is proposed for application as sorbent for solid-phase extraction (SPE) and simultaneously as substrate for surface-enhanced Raman spectroscopy (SERS) due to their high sorption properties and ability to enhance Raman signal (SERS-active sorbents). SiO2-AgNP was synthesized via alkaline hydrolysis of tetraethyl orthosilicate with simultaneous reduction of silver ions to silver nanoparticles (AgNP) within the SiO2 bulk. Synthesis of AgNP directly to the SiO2 matrix enables to exclude any additional stabilizers for the nanoparticles that educes signal-to-noise ratio during SERS measurement. Apart from Raman spectroscopy, obtained sorbents were also characterized by scanning electron microscopy and UV-visible diffuse reflectance spectroscopy. The influence of AgNO3 concentration used during the SiO2-AgNP synthesis on its gelling time, color, diffuse reflectance spectra, and enhancement of Raman signal was investigated. A Raman enhancement factor of SiO2-AgNP with optimal composition was around 105. Finally, the sorbents were applied for SPE and subsequent SERS detection of model compounds (rhodamine 6G and folic acid). It was found that SPE enables to decrease detectable concentrations by two orders. Therefore, SPE combined with SERS has high potential for further analytical investigations.

  1. Multifunctional silver nanoparticle-doped silica for solid-phase extraction and surface-enhanced Raman scattering detection

    Energy Technology Data Exchange (ETDEWEB)

    Markina, Natalia E.; Markin, Alexey V., E-mail: av-markin@mail.ru; Zakharevich, Andrey M.; Gorin, Dmitry A.; Rusanova, Tatiana Yu.; Goryacheva, Irina Yu. [Saratov State University (Russian Federation)

    2016-12-15

    Multifunctional silica gel with embedded silver nanoparticles (SiO{sub 2}–AgNP) is proposed for application as sorbent for solid-phase extraction (SPE) and simultaneously as substrate for surface-enhanced Raman spectroscopy (SERS) due to their high sorption properties and ability to enhance Raman signal (SERS-active sorbents). SiO{sub 2}–AgNP was synthesized via alkaline hydrolysis of tetraethyl orthosilicate with simultaneous reduction of silver ions to silver nanoparticles (AgNP) within the SiO{sub 2} bulk. Synthesis of AgNP directly to the SiO{sub 2} matrix enables to exclude any additional stabilizers for the nanoparticles that educes signal-to-noise ratio during SERS measurement. Apart from Raman spectroscopy, obtained sorbents were also characterized by scanning electron microscopy and UV-visible diffuse reflectance spectroscopy. The influence of AgNO{sub 3} concentration used during the SiO{sub 2}–AgNP synthesis on its gelling time, color, diffuse reflectance spectra, and enhancement of Raman signal was investigated. A Raman enhancement factor of SiO{sub 2}–AgNP with optimal composition was around 10{sup 5}. Finally, the sorbents were applied for SPE and subsequent SERS detection of model compounds (rhodamine 6G and folic acid). It was found that SPE enables to decrease detectable concentrations by two orders. Therefore, SPE combined with SERS has high potential for further analytical investigations.

  2. Rapid and sensitive phenotypic marker detection on breast cancer cells using surface-enhanced Raman scattering (SERS) imaging.

    Science.gov (United States)

    Lee, Sangyeop; Chon, Hyangah; Lee, Jiyoung; Ko, Juhui; Chung, Bong Hyun; Lim, Dong Woo; Choo, Jaebum

    2014-01-15

    We report a surface-enhanced Raman scattering (SERS)-based cellular imaging technique to detect and quantify breast cancer phenotypic markers expressed on cell surfaces. This technique involves the synthesis of SERS nano tags consisting of silica-encapsulated hollow gold nanospheres (SEHGNs) conjugated with specific antibodies. Hollow gold nanospheres (HGNs) enhance SERS signal intensity of individual particles by localizing surface electromagnetic fields through pinholes in the hollow particle structures. This capacity to enhance imaging at the level of single molecules permits the use of HGNs to detect specific biological markers expressed in living cancer cells. In addition, silica encapsulation greatly enhances the stability of nanoparticles. Here we applied a SERS-based imaging technique using SEHGNs in the multiplex imaging of three breast cancer cell phenotypes. Expression of epidermal growth factor (EGF), ErbB2, and insulin-like growth factor-1 (IGF-1) receptors were assessed in the MDA-MB-468, KPL4 and SK-BR-3 human breast cancer cell lines. SERS imaging technology described here can be used to test the phenotype of a cancer cell and quantify proteins expressed on the cell surface simultaneously. Based on results, this technique may enable an earlier diagnosis of breast cancer than is currently possible and offer guidance in treatment. © 2013 Elsevier B.V. All rights reserved.

  3. Structure-selective hot-spot Raman enhancement for direct identification and detection of trace penicilloic acid allergen in penicillin.

    Science.gov (United States)

    Zhang, Liying; Jin, Yang; Mao, Hui; Zheng, Lei; Zhao, Jiawei; Peng, Yan; Du, Shuhu; Zhang, Zhongping

    2014-08-15

    Trace penicilloic acid allergen frequently leads to various fatal immune responses to many patients, but it is still a challenge to directly discriminate and detect its residue in penicillin by a chemosensing way. Here, we report that silver-coated gold nanoparticles (Au@Ag NPs) exhibit a structure-selective hot-spot Raman enhancement capability for direct identification and detection of trace penicilloic acid in penicillin. It has been demonstrated that penicilloic acid can very easily link Au@Ag NPs together by its two carboxyl groups, locating itself spontaneously at the interparticle of Au@Ag NPs to form strong Raman hot-spot. At the critical concentration inducing the nanoparticle aggregation, Raman-enhanced effect of penicilloic acid is ~60,000 folds higher than that of penicillin. In particular, the selective Raman enhancement to the two carboxyl groups makes the peak of carboxyl group at C6 of penicilloic acid appear as a new Raman signal due to the opening of β-lactam ring of penicillin. The surface-enhanced Raman scattering (SERS) nanoparticle sensor reaches a sensitive limit lower than the prescribed 1.0‰ penicilloic acid residue in penicillin. The novel strategy to examine allergen is more rapid, convenient and inexpensive than the conventional separation-based assay methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Comparison of gadolinium-EOB-DTPA-enhanced and diffusion-weighted liver MRI for detection of small hepatic metastases.

    Science.gov (United States)

    Shimada, Kotaro; Isoda, Hiroyoshi; Hirokawa, Yuusuke; Arizono, Shigeki; Shibata, Toshiya; Togashi, Kaori

    2010-11-01

    To compare the accuracy of gadolinium ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI with that of diffusion-weighted MRI (DWI) in the detection of small hepatic metastases (2 cm or smaller). Forty-five patients underwent abdominal MRI at 3 T, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), heavily T2WI (HASTE), DWI with a b-value of 500 s/mm(2) and contrast-enhanced MRI with Gd-EOB-DTPA. Two groups were assigned and compared: group A (T1WI, T2WI, HASTE and contrast-enhanced study with Gd-EOB-DTPA), and group B (T1WI, T2WI, HASTE and DWI). Two observers independently interpreted the images obtained in a random order. For all hepatic metastases, the diagnostic performance using each imaging set was evaluated by receiver-operating characteristic (ROC) curve analysis. A total of 51 hepatic metastases were confirmed. The area under the ROC curve (Az) of group A was larger than that of group B, and the difference in the mean Az values between the two image sets was statistically significant, whereas, there were three metastases that lay near thin vessels or among multiple cysts and were better visualised in group B than in group A. Gd-EOB-DTPA-enhanced MRI showed higher accuracy in the detection of small metastases than DWI.

  5. Shape anisotropy enhanced optomagnetic measurement for prostate-specific antigen detection via magnetic chain formation

    DEFF Research Database (Denmark)

    Tian, Bo; Wetterskog, Erik; Qiu, Zhen

    2017-01-01

    anisotropy), and directly increasing the optomagnetic signal (via optical shape anisotropy). We achieve a limit of detection (LOD) of 5.5 pM (0.82 ng/mL) for the detection of a model multivalent molecule, biotinylated anti-streptavidin, in PBS. For the measurements of prostate-specific antigen (PSA) in 50...

  6. Spin-lock MR enhances the detection sensitivity of superparamagnetic iron oxide particles

    NARCIS (Netherlands)

    Moonen, R.P.M.; van der Tol, P.; Hectors, S.J.C.G.; Starmans, L.W.E.; Nicolaij, K.; Strijkers, G.J.

    2015-01-01

    Purpose To evaluate spin-lock MR for detecting superparamagnetic iron oxides and compare the detection sensitivity of quantitative T1ρ with T2 imaging. Methods In vitro experiments were performed to investigate the influence of iron oxide particle size and composition on T1ρ. These comprise T1ρ and

  7. Spin-lock MR enhances the detection sensitivity of superparamagnetic iron oxide particles

    NARCIS (Netherlands)

    Moonen, Rik P. M.; van der Tol, Pieternel; Hectors, Stefanie J. C. G.; Starmans, Lucas W. E.; Nicolay, Klaas; Strijkers, Gustav J.

    2015-01-01

    To evaluate spin-lock MR for detecting superparamagnetic iron oxides and compare the detection sensitivity of quantitative T1ρ with T2 imaging. In vitro experiments were performed to investigate the influence of iron oxide particle size and composition on T1ρ . These comprise T1ρ and T2 measurements

  8. Sensitivity of enhanced MRI for the detection of breast cancer: new, multicentric, residual, and recurrent

    International Nuclear Information System (INIS)

    Davis, P.L.; McCarty, K.S. Jr.

    1997-01-01

    Magnetic resonance imaging (MRI) of the breast brings the advantages of high resolution cross-sectional imaging to breast cancer diagnosis, treatment and research: improved cancer detection, staging, selection of therapy, evaluation of therapeutic response in vivo, detection of recurrence, and even the development of new therapies. Until now breast cancer treatment and research has been impeded by the limited means of evaluating the breast cancer in vivo: primarily clinical palpation and mammography of the breast tumor. A review of the initial studies shows that with the use of paramagnetic contrast agents, MRI has a sensitivity of 96 % for detecting breast cancers. MRI detects multicentric disease with a sensitivity of 98 %, superior to any other modality. The ability of MRI to detect recurrent local breast cancer in the conservatively treated breast is nearly 100 %. MRI is capable of monitoring tumor response to chemotherapy and actually guiding therapeutic interventions such as interstitial laser photocoagulation. (orig.)

  9. Platinum plasmonic nanostructure arrays for massively parallel single-molecule detection based on enhanced fluorescence measurements

    International Nuclear Information System (INIS)

    Saito, Toshiro; Takahashi, Satoshi; Obara, Takayuki; Itabashi, Naoshi; Imai, Kazumichi

    2011-01-01

    We fabricated platinum bowtie nanostructure arrays producing fluorescence enhancement and evaluated their performance using two-photon photoluminescence and single-molecule fluorescence measurements. A comprehensive selection of suitable materials was explored by electromagnetic simulation and Pt was chosen as the plasmonic material for visible light excitation near 500 nm, which is preferable for multicolor dye-labeling applications like DNA sequencing. The observation of bright photoluminescence (λ = 500-600 nm) from each Pt nanostructure, induced by irradiation at 800 nm with a femtosecond laser pulse, clearly indicates that a highly enhanced local field is created near the Pt nanostructure. The attachment of a single dye molecule was attempted between the Pt triangles of each nanostructure by using selective immobilization chemistry. The fluorescence intensities of the single dye molecule localized on the nanostructures were measured. A highly enhanced fluorescence, which was increased by a factor of 30, was observed. The two-photon photoluminescence intensity and fluorescence intensity showed qualitatively consistent gap size dependence. However, the average fluorescence enhancement factor was rather repressed even in the nanostructure with the smallest gap size compared to the large growth of photoluminescence. The variation of the position of the dye molecule attached to the nanostructure may influence the wide distribution of the fluorescence enhancement factor and cause the rather small average value of the fluorescence enhancement factor.

  10. A baseband circuit for wake-up receivers with double-mode detection and enhanced sensitivity robustness

    International Nuclear Information System (INIS)

    Zhu Wenrui; Yang Haigang; Gao Tongqiang; Liu Fei; Cheng Xiaoyan; Zhang Dandan

    2013-01-01

    This paper proposes a baseband circuit for wake-up receivers with double-mode detection and enhanced sensitivity robustness for use in the electronic toll collection system. A double-mode detection method, including amplitude detection and frequency detection, is proposed to reject interference and reduce false wake-ups. An improved closed-loop band-pass filter and a DC offset cancellation technique are also newly introduced to enhance the sensitivity robustness. The circuit is fabricated in TSMC 0.18 μm 3.3 V CMOS technology with an area of 0.12 mm 2 . Measurement results show that the sensitivity is −54.5 dBm with only a ±0.95 dBm variation from the 1.8 to 3.3 V power supply, and that the temperature variation of the sensitivity is ±1.4 dBm from −50 to 100°C. The current consumption is 1.4 to 1.7 μA under a 1.8 to 3.3 V power supply. (semiconductor integrated circuits)

  11. Curcumin-Based "Enhanced SNAr" Promoted Ultrafast Fluorescent Probe for Thiophenols Detection in Aqueous Solution and in Living Cells.

    Science.gov (United States)

    Yue, Yongkang; Huo, Fangjun; Zhang, Yongbin; Chao, Jianbin; Martínez-Máñez, Ramón; Yin, Caixia

    2016-11-01

    We report herein a highly selective and sensitive turn-on fluorescent probe (compound 1) with a fast response time (less than 2 min) for thiophenol detection based on an "enhanced S N Ar" reaction between thiophenols and a sulfonyl-ester moiety covalently attach to curcumin. Reaction of 1 in Hepes-MeOH (1:1, v/v, pH 7.4) in the presence of 4-methylthiophenol (MTP) resulted in a remarkable enhancement of the fluorescence. A linear response in the presence of MTP of the relative fluorescent intensity (F - F 0 ) of 1 at 536 nm in the 0-40 μM MTP concentration range was found. A limit of detection (LOD) for the detection of MTP of 26 nM, based on the definition by IUPAC (C DL = 3 Sb/m), was calculated. Probe 1 was applied to monitor and imaging exogenous MTP in live cells and to the detection of MTP in real water samples.

  12. Near-infrared incoherent broadband cavity enhanced absorption spectroscopy (NIR-IBBCEAS) for detection and quantification of natural gas components.

    Science.gov (United States)

    Prakash, Neeraj; Ramachandran, Arun; Varma, Ravi; Chen, Jun; Mazzoleni, Claudio; Du, Ke

    2018-06-28

    The principle of near-infrared incoherent broadband cavity enhanced absorption spectroscopy was employed to develop a novel instrument for detecting natural gas leaks as well as for testing the quality of natural gas mixtures. The instrument utilizes the absorption features of methane, butane, ethane, and propane in the wavelength region of 1100 nm to 1250 nm. The absorption cross-section spectrum in this region for methane was adopted from the HITRAN database, and those for the other three gases were measured in the laboratory. A singular-value decomposition (SVD) based analysis scheme was employed for quantifying methane, butane, ethane, and propane by performing a linear least-square fit. The developed instrument achieved a detection limit of 460 ppm, 141 ppm, 175 ppm and 173 ppm for methane, butane, ethane, and propane, respectively, with a measurement time of 1 second and a cavity length of 0.59 m. These detection limits are less than 1% of the Lower Explosive Limit (LEL) for each gas. The sensitivity can be further enhanced by changing the experimental parameters (such as cavity length, lamp power etc.) and using longer averaging intervals. The detection system is a low-cost and portable instrument suitable for performing field monitorings. The results obtained on the gas mixture emphasize the instrument's potential for deployment at industrial facilities dealing with natural gas, where potential leaks pose a threat to public safety.

  13. Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound.

    Science.gov (United States)

    Klauser, Andrea S; Franz, Magdalena; Arora, Rohit; Feuchtner, Gudrun M; Gruber, Johann; Schirmer, Michael; Jaschke, Werner R; Gabl, Markus F

    2010-01-01

    We sought to assess vascularity in wrist tenosynovitis by using power Doppler ultrasound (PDUS) and to compare detection of intra- and peritendinous vascularity with that of contrast-enhanced grey-scale ultrasound (CEUS). Twenty-six tendons of 24 patients (nine men, 15 women; mean age ± SD, 54.4 ± 11.8 years) with a clinical diagnosis of tenosynovitis were examined with B-mode ultrasonography, PDUS, and CEUS by using a second-generation contrast agent, SonoVue (Bracco Diagnostics, Milan, Italy) and a low-mechanical-index ultrasound technique. Thickness of synovitis, extent of vascularized pannus, intensity of peritendinous vascularisation, and detection of intratendinous vessels was incorporated in a 3-score grading system (grade 0 to 2). Interobserver variability was calculated. With CEUS, a significantly greater extent of vascularity could be detected than by using PDUS (P < 0.001). In terms of peri- and intratendinous vessels, CEUS was significantly more sensitive in the detection of vascularization compared with PDUS (P < 0.001). No significant correlation between synovial thickening and extent of vascularity could be found (P = 0.089 to 0.097). Interobserver reliability was calculated to be excellent when evaluating the grading score (κ = 0.811 to 1.00). CEUS is a promising tool to detect tendon vascularity with higher sensitivity than PDUS by improved detection of intra- and peritendinous vascularity.

  14. Paper-based microfluidic approach for surface-enhanced raman spectroscopy and highly reproducible detection of proteins beyond picomolar concentration.

    Science.gov (United States)

    Saha, Arindam; Jana, Nikhil R

    2015-01-14

    Although microfluidic approach is widely used in various point of care diagnostics, its implementation in surface enhanced Raman spectroscopy (SERS)-based detection is challenging. This is because SERS signal depends on plasmonic nanoparticle aggregation induced generation of stable electromagnetic hot spots and in currently available microfluidic platform this condition is difficult to adapt. Here we show that SERS can be adapted using simple paper based microfluidic system where both the plasmonic nanomaterials and analyte are used in mobile phase. This approach allows analyte induced controlled particle aggregation and electromagnetic hot spot generation inside the microfluidic channel with the resultant SERS signal, which is highly reproducible and sensitive. This approach has been used for reproducible detection of protein in the pico to femtomolar concentration. Presented approach is simple, rapid, and cost-effective, and requires low sample volume. Method can be extended for SERS-based detection of other biomolecules.

  15. Rapid and sensitive detection of malachite green in aquaculture water by electrochemical preconcentration and surface-enhanced Raman scattering.

    Science.gov (United States)

    Xu, Kai-Xuan; Guo, Mei-Hong; Huang, Yu-Ping; Li, Xiao-Dong; Sun, Jian-Jun

    2018-04-01

    A highly sensitive and rapid method of in-situ surface-enhanced Raman spectroscopy (SERS) combining with electrochemical preconcentration (EP) in detecting malachite green (MG) in aquaculture water was established. Ag nanoparticles (AgNPs) were synthesized and spread onto the surface of gold electrodes after centrifuging to produce SERS-active substrates. After optimizing the pH values, preconcentration potentials and times, in-situ EP-SERS detection was carried out. A sensitive and rapid analysis of the low-concentration MG was accomplished within 200s and the limit of detection was 2.4 × 10 -16 M. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. An Efficient Method for Detection of Outliers in Tracer Curves Derived from Dynamic Contrast-Enhanced Imaging

    Directory of Open Access Journals (Sweden)

    Linning Ye

    2018-01-01

    Full Text Available Presence of outliers in tracer concentration-time curves derived from dynamic contrast-enhanced imaging can adversely affect the analysis of the tracer curves by model-fitting. A computationally efficient method for detecting outliers in tracer concentration-time curves is presented in this study. The proposed method is based on a piecewise linear model and implemented using a robust clustering algorithm. The method is noniterative and all the parameters are automatically estimated. To compare the proposed method with existing Gaussian model based and robust regression-based methods, simulation studies were performed by simulating tracer concentration-time curves using the generalized Tofts model and kinetic parameters derived from different tissue types. Results show that the proposed method and the robust regression-based method achieve better detection performance than the Gaussian model based method. Compared with the robust regression-based method, the proposed method can achieve similar detection performance with much faster computation speed.

  17. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Initial Radiometric Characteristics of KOMPSAT-3A Multispectral Imagery Using the 6S Radiative Transfer Model, Well-Known Radiometric Tarps, and MFRSR Measurements

    Directory of Open Access Journals (Sweden)

    Jong-Min Yeom

    2017-02-01

    Full Text Available On-orbit radiometric characterization of the multispectral (MS imagery of the Korea Aerospace Research Institute (KARI’s Korea Multi-Purpose Satellite-3A (KOMPSAT-3A, which was launched on 25 March 2015, was conducted to provide quantitative radiometric information about KOMPSAT-3A. During the in-orbit test (IOT, vicarious radiometric calibration of KOMPSAT-3A was performed using the Second Simulation of a Satellite Signal in the Solar Spectrum (6S radiative transfer model. The characteristics of radiometric tarps, the atmospheric optical depth from multi-filter rotating shadowband radiometer (MFRSR measurements, and sun–sensor–geometry were carefully considered, in order to calculate the exact top of atmosphere (TOA radiance received by KOMPSAT-3A MS bands. In addition, the bidirectional reflectance distribution function (BRDF behaviors of the radiometric tarps were measured in the laboratory with a two-dimensional hyperspectral gonioradiometer, to compensate for the geometry discrepancy between the satellite and the ASD FieldSpec® 3 spectroradiometer. The match-up datasets between the TOA radiance and the digital number (DN from KOMPSAT-3A were used to determine DN-to-radiance conversion factors, based on linear least squares fitting for two field campaigns. The final results showed that the R2 values between the observed and simulated radiances for the blue, green, red, and near-infrared (NIR bands, are greater than 0.998. An approximate error budget analysis for the vicarious calibration of KOMPSAT-3A showed an error of less than 6.8%. When applying the laboratory-based BRDF correction to the case of higher viewing zenith angle geometry, the gain ratio was improved, particularly for the blue (1.3% and green (1.2% bands, which exhibit high sensitivity to the BRDF of radiometric tarps during the backward-scattering phase. The calculated gain ratio between the first and second campaigns showed a less than 5% discrepancy, indicating that

  19. Enhancing spatial detection accuracy for syndromic surveillance with street level incidence data

    Directory of Open Access Journals (Sweden)

    Alemi Farrokh

    2010-01-01

    Full Text Available Abstract Background The Department of Defense Military Health System operates a syndromic surveillance system that monitors medical records at more than 450 non-combat Military Treatment Facilities (MTF worldwide. The Electronic Surveillance System for Early Notification of Community-based Epidemics (ESSENCE uses both temporal and spatial algorithms to detect disease outbreaks. This study focuses on spatial detection and attempts to improve the effectiveness of the ESSENCE implementation of the spatial scan statistic by increasing the spatial resolution of incidence data from zip codes to street address level. Methods Influenza-Like Illness (ILI was used as a test syndrome to develop methods to improve the spatial accuracy of detected alerts. Simulated incident clusters of various sizes were superimposed on real ILI incidents from the 2008/2009 influenza season. Clusters were detected using the spatial scan statistic and their displacement from simulated loci was measured. Detected cluster size distributions were also evaluated for compliance with simulated cluster sizes. Results Relative to the ESSENCE zip code based method, clusters detected using street level incidents were displaced on average 65% less for 2 and 5 mile radius clusters and 31% less for 10 mile radius clusters. Detected cluster size distributions for the street address method were quasi normal and sizes tended to slightly exceed simulated radii. ESSENCE methods yielded fragmented distributions and had high rates of zero radius and oversized clusters. Conclusions Spatial detection accuracy improved notably with regard to both location and size when incidents were geocoded to street addresses rather than zip code centroids. Since street address geocoding success rates were only 73.5%, zip codes were still used for more than one quarter of ILI cases. Thus, further advances in spatial detection accuracy are dependant on systematic improvements in the collection of individual

  20. Phosphodiesterase (PDE5) inhibition assay for rapid detection of erectile dysfunction drugs and analogs in sexual enhancement products.

    Science.gov (United States)

    Santillo, Michael F; Mapa, Mapa S T

    2018-02-28

    Products marketed as dietary supplements for sexual enhancement are frequently adulterated with phosphodiesterase-5 (PDE5) inhibitors, which are erectile dysfunction drugs or their analogs that can cause adverse health effects. Due to widespread adulteration, a rapid screening assay was developed to detect PDE5 inhibitors in adulterated products. The assay employs fluorescence detection and is based on measuring inhibition of PDE5 activity, the pharmacological mechanism shared among the adulterants. Initially, the assay reaction scheme was established and characterized, followed by analysis of 9 representative PDE5 inhibitors (IC 50 , 0.4-4.0 ng mL -1 ), demonstrating sensitive detection in matrix-free solutions. Next, dietary supplements serving as matrix blanks (n = 25) were analyzed to determine matrix interference and establish a threshold value; there were no false positives. Finally, matrix blanks were spiked with 9 individual PDE5 inhibitors, along with several mixtures. All 9 adulterants were successfully detected (≤ 5 % false negative rate; n = 20) at a concentration of 1.00 mg g -1 , which is over 5 times lower than concentrations commonly encountered in adulterated products. A major distinction of the PDE5 inhibition assay is the ability to detect adulterants without prior knowledge of their chemical structures, demonstrating a broad-based detection capability that can address a continuously evolving threat of new adulterants. The PDE5 inhibition assay can analyze over 40 samples simultaneously within 15 minutes and involves a single incubation step and simple data analysis, all of which are advantageous for combating the widespread adulteration of sex-enhancement products. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.