WorldWideScience

Sample records for enhanced helical ct

  1. Patterns of uterine enhancement with helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, H.; Loyer, E.M.; Charnsangavej, C. [Department of Diagnostic Radiology, Box 57, The University of Texas, M.D. Anderson Cancer Center, 1515 Holcombe Blvd. Houston, TX 77030 (United States); Minami, M. [Department of Radiology, Faculty of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo 113 (Japan)

    1998-10-01

    Objective: The purpose of this study was to evaluate the enhancement characteristics of the normal uterine body and cervix using dynamic contrast-enhanced helical CT. Methods: Thirty-eight women scheduled for pelvic CT for non-gynecologic malignancies underwent dynamic contrast-enhanced helical CT of the pelvis. Data acquisition was during the arterial phase (30-45 s after the start of injection), the parenchymal phase (90-120 s after the start of injection), and delayed phase (3-9 min after the start of injection). The images were evaluated by four radiologists for the pattern of myometrial and cervical enhancement. Correlation was made with the age and menstrual status of the patients. Results: In the uterine body, three types of enhancement were observed. Type 1 enhancement, seen in 16 patients (42%), was characterized by the visualization of a subendometrial zone of enhancement, 30-120 s after the start of injection. Eight of these patients also showed an enhancing zone in the outer myometrium. Both zones were transitory, and in all cases, the uterus became homogeneous in the delayed phase. This pattern was seen predominantly in premenopausal women with a mean age of 34 years. Type 2 enhancement, seen in 17 cases (45%), was defined by the absence of subendometrial enhancement in the early phase. Enhancement was either diffuse from the outset or originated in the outer myometrium. This pattern was seen nearly equally in premenopausal and postmenopausal women with a mean age of 40 years. Type 3 enhancement was seen in five postmenopausal patients (13%) with a mean age of 53 years and was characterized by faint diffuse enhancement. In the cervix, a zonal pattern of enhancement defining inner and outer stroma was seen in 23 patients (61%). Fifteen patients were premenopausal and eight were postmenopausal. Conclusion: In this study, we have shown a transitory zonal distribution of the contrast in the myometrium and cervix using dynamic contrast-enhanced helical CT

  2. Patterns of uterine enhancement with helical CT

    International Nuclear Information System (INIS)

    Kaur, H.; Loyer, E.M.; Charnsangavej, C.; Minami, M.

    1998-01-01

    Objective: The purpose of this study was to evaluate the enhancement characteristics of the normal uterine body and cervix using dynamic contrast-enhanced helical CT. Methods: Thirty-eight women scheduled for pelvic CT for non-gynecologic malignancies underwent dynamic contrast-enhanced helical CT of the pelvis. Data acquisition was during the arterial phase (30-45 s after the start of injection), the parenchymal phase (90-120 s after the start of injection), and delayed phase (3-9 min after the start of injection). The images were evaluated by four radiologists for the pattern of myometrial and cervical enhancement. Correlation was made with the age and menstrual status of the patients. Results: In the uterine body, three types of enhancement were observed. Type 1 enhancement, seen in 16 patients (42%), was characterized by the visualization of a subendometrial zone of enhancement, 30-120 s after the start of injection. Eight of these patients also showed an enhancing zone in the outer myometrium. Both zones were transitory, and in all cases, the uterus became homogeneous in the delayed phase. This pattern was seen predominantly in premenopausal women with a mean age of 34 years. Type 2 enhancement, seen in 17 cases (45%), was defined by the absence of subendometrial enhancement in the early phase. Enhancement was either diffuse from the outset or originated in the outer myometrium. This pattern was seen nearly equally in premenopausal and postmenopausal women with a mean age of 40 years. Type 3 enhancement was seen in five postmenopausal patients (13%) with a mean age of 53 years and was characterized by faint diffuse enhancement. In the cervix, a zonal pattern of enhancement defining inner and outer stroma was seen in 23 patients (61%). Fifteen patients were premenopausal and eight were postmenopausal. Conclusion: In this study, we have shown a transitory zonal distribution of the contrast in the myometrium and cervix using dynamic contrast-enhanced helical CT

  3. Comparison of AMI-25 enhanced MRI and helical dynamic CT in the detection of hepatic lesions

    International Nuclear Information System (INIS)

    Saitou, Kazuhiro; Matsuda, Hiromichi; Fukushima, Hiroaki; Kanzaki, Hiroshi; Hirose, Takashi; Karizaki, Dai; Abe, Kimihiko; Amino, Saburou

    1994-01-01

    We performed AMI-25 enhanced MRI and helical dynamic CT in 12 cases of hepatic lesions. Nine of these were hepatocellular carcinomas. Two cases were metastatic liver tumors (the primary lesion was gastric in one and the other was gallbladder cancer). One case was suspected to be adenomatous hyperplasia. Thirty-two lesions were detected in T2-weighted SE images before AMI-25 administration, while 46 lesions were detected in AMI-25 enhanced MRI images. In particular, AMI-25 enhanced MRI was superior to plain MRI in lesions less than 10 mm in size. A total of 48 lesions were detected in helical dynamic CT. Although AMI-25 enhanced MRI almost equaled helical dynamic CT in the detection of liver tumors, helical dynamic CT was slightly superior to AMI-25 enhanced MRI in the detection of subphrenic lesions. It was possible to know the hemodynamics in each hepatic lesion by helical dynamic CT. AMI-25 enhanced MRI was useful to know the inclusion of reticuloendothelial system, and that yielded different diagnoses in adenomatous hyperplasia and well differentiated hepatocellular carcinoma. Helical dynamic CT was useful for qualitative diagnosis. Both AMI-25 enhanced MRI and helical dynamic CT contributed to the detection of liver tumor and qualitative diagnosis. (author)

  4. Evaluation of residual hepatocellular carcinoma after transcatheter arterial chemoembolization: Comparison between contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Lim, Hyo Keun; Lee, Won Jae

    2001-01-01

    To evaluate the effectiveness of contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography (PDUS) in assessing the therapeutic effect of transcatheter arterial chemoembolization (TACE) in hepatocellular carcinomas (HCCs). The follow-up contrast-enhanced helical CT and contrast-enhanced PDUS were performed for twenty-nine nodular HCCs from twelve patients previously treated with TACE. We defined the residual HCCs as intratumoral enhancing area on contrast-enhanced helical CT and color signal on contrast-enhanced PDUS. The interval between two examinations was less than 2 weeks (mean, 9 days). Two radiologists evaluated two examinations by consensus, and the results of these two examination were compared with the findings of other examinations including CT, angiography, and/or pathology to calculate the sensitivity, specificity and accuracy of two examinations. Of the 29 HCCs, 20 had residual HCCs whereas no residual HCCs in 9 HCCs on pathologic examination and/or follow-up radiologic study. The sensitivity, sensitivity and accuracy of contrast-enhanced helical CT were 65 (13/20), 89 (8/9), and 72% (21/29) while those of contrast-enhanced PDUS were 100 (20/20), 89 (8/9) and 97% (28/29), respectively. A microbubble contrast-enhanced PDUS was more effective in the detection of residual tumor in HCCs following TACE than contrast-enhanced helical CT.

  5. Gynecological applications of helical CT using SmartPrep

    Energy Technology Data Exchange (ETDEWEB)

    Sakurada, Akira; Kakizaki, Dai; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1999-11-01

    SmartPrep is software program for scanning a given region of interest (ROI) at optimal contrast density. An operator can arbitrarily define ROI and preset the CT value at which scanning should be started. After the injection of a contrast medium, system conducts continuous monitoring of the ROI and the operator starts helical scanning of the planned region when the present CT value has been reached. In comparison with conventional helical CT that requires a period of time from the beginning of contrast medium injection to the beginning of scanning, SmartPrep minimizes personal error and better depicts the artery-predominant phase under optimal conditions. In this study we examine the usefulness of contrast-enhanced helical CT using SmartPrep in the evaluation of gynecological disease. When the contrast medium was injected into the dorsal vein of the hand at a rate of 3 ml/sec, strong staining of pelvic arteries was observed in the CT images started at 17 to 23 sec after injection. The early-phase helical CT obtained under these conditions provided good depiction of lesions in cases of placenta accreta and invasive mole, as well as clear demonstration of tumor angiogenesis and evaluation of laterality in cases of cervical cancer. Comparison of the early and delayed phase also facilitated easier evaluation of lymph nodes than conventional comparison of simple and contrast-enhanced CT. The results thus suggest the usefulness of contrast-enhanced helical CT using SmartPrep in gynecology. (author)

  6. Dynamic helical CT mammography of breast cancer

    International Nuclear Information System (INIS)

    Yamamoto, Akira; Fukushima, Hitoshi; Okamura, Ryuji; Nakamura, Yoshiaki; Morimoto, Taisuke; Urata, Yoji; Mukaihara, Sumio; Hayakawa, Katsumi

    2006-01-01

    The purpose of this study was to determine whether dynamic helical computed tomography (CT)-mammography could assist in selecting the most appropriate surgical method in women with breast cancer. Preoperative contrast-enhanced helical CT scanning of the breast was performed on 133 female patients with suspicion of breast cancer at the same time as clinical, mammographic, and/or ultrasonographic examinations. The patients were scanned in the prone position with a specially designed CT-compatible device. A helical scan was made with rapid intravenous bolus injection (3 ml/s) of 100 ml of iodine contrast material. Three-dimensional maximum intensity projection (MIP) images were reconstructed, and CT findings were correlated with surgical and histopathological findings. Histopathological analysis revealed 84 malignant lesions and seven benign lesions. The sensitivity, specificity, and accuracy levels of the CT scanning were 94.6%, 58.6%, and 78.9%. Helical scanning alone revealed additional contralateral carcinomas in three of four patients and additional ipsilateral carcinomas in three of five patients. However, the technique gave false-positive readings in 24 patients. The preoperative CT-mammogram altered the surgical method in six patients. Dynamic helical CT-mammography in the prone position may be one of the choices of adjunct imaging in patients with suspected breast cancer scheduled for surgery. (author)

  7. Contrast-enhanced helical CT of the pancreas. Optimal timing of imaging for pancreatic tumor evaluation

    International Nuclear Information System (INIS)

    Koide, Kazuki; Sekiguchi, Ryuzo

    2001-01-01

    We performed three-phase helical CT in patients suspected pancreatic tumors and investigated the optimal timing of imaging for evaluation of the pancreatic mass. The pancreatic-phase was superior in detecting pancreatic tumors, including islet cell tumors that may show strong enhancement. However, portal vein-phase imaging was also superior in 16.7% of our patients. Taking into account examination for hepatic metastasis, helical CT of any pancreatic tumor should include images obtained in the pancreatic and portal vein phases. (author)

  8. Helical CT defecography

    International Nuclear Information System (INIS)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M.; Tornago, S.

    1999-01-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases [it

  9. Diagnostic value of triphasic incremental helical CT in early and progressive gastric carcinoma

    International Nuclear Information System (INIS)

    Gao Jianbo; Yan Xuehua; Li Mengtai; Guo Hua; Chen Xuejun; Guan Sheng; Zhang Xiefu; Li Shuxin; Yang Xiaopeng

    2001-01-01

    Objective: To investigate helical CT enhancement characteristics of gastric carcinoma, and the diagnostic value and preoperative staging of gastric carcinoma with triphasic incremental helical CT of the stomach with water-filling method. Methods: Both double-contrast barium examination and triphasic incremental helical CT of the stomach with water-filling method were performed in 46 patients with gastric carcinoma. Results: (1) Among these patients, normal gastric wall exhibited one layered structure in 18 patients, two or three layered structure in 28 patients in the arterial and portal venous phase. (2) Two cases of early stomach cancer showed marked enhancement in the arterial and portal venous phase and obvious attenuation of enhancement in the equilibrium phase. On the contrary, 32 of the 44 advanced gastric carcinoma was showed marked enhancement in the venous phase compared with the arterial phase ( t = 4.226, P < 0.05). (3) The total accuracy of triphasic incremental helical CT in determining TNM-staging was 81.0%. Conclusion: Different types of gastric carcinoma have different enhancement features. Triphases incremental helical CT is more accurate than conventional CT in the preoperative staging of gastric carcinoma

  10. Three-dimensional helical CT for treatment planning of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hiramatsu, Hideko; Enomoto, Kohji; Ikeda, Tadashi [Keio Univ., Tokyo (Japan). School of Medicine] [and others

    1999-01-01

    The role of three-dimensional (3D) helical CT in the treatment planning of breast cancer was evaluated. Of 36 patients examined, 30 had invasive ductal carcinoma, three had invasive lobular carcinoma, one had DCIS, one had DCIS with minimal invasion, and 1 had Paget`s disease. Patients were examined in the supine position. The whole breast was scanned under about 25 seconds of breath-holding using helical CT (Proceed, Yokogawa Medical Systems, or High-speed Advantage, GE Medical Systems). 3D imaging was obtained with computer assistance (Advantage Windows, GE Medical Systems). Linear and/or spotty enhancement on helical CT was considered to suggest DCIS or intraductal spread in the area surrounding the invasive cancer. Of 36 patients, 24 showed linear and/or spotty enhancement on helical CT, and 22 of those 24 patients had DCIS or intraductal spread. In contrast, 12 of 36 patients were considered to have little or no intraductal spread on helical CT, and eight of the 12 patients had little or no intraductal spread on pathological examination. The sensitivity, specificity, and accuracy rates for detecting intraductal spread on MRI were 85%, 80%, and 83%, respectively. 3D helical CT was considered useful in detecting intraductal spread and planning surgery, however, a larger study using a precise correlation with pathology is necessary. (author)

  11. Peripancreatic vascular abnormalities complicating acute pancreatitis: contrast-enhanced helical CT findings

    International Nuclear Information System (INIS)

    Mortele, Koenraad J.; Mergo, Patricia J.; Taylor, Helena M.; Wiesner, Walter; Cantisani, Vito; Ernst, Michael D.; Kalantari, Babak N.; Ros, Pablo R.

    2004-01-01

    Objective: To determine the prevalence and morphologic helical computed tomography (CT) features of peripancreatic vascular abnormalities in patients with acute pancreatic inflammatory disease in correlation with the severity of the pancreatitis. Materials and methods: One hundred and fifty-nine contrast-enhanced helical CT scans of 100 consecutive patients with acute pancreatitis were retrospectively and independently reviewed by three observers. CT scans were scored using the CT severity index (CTSI): pancreatitis was graded as mild (0-2 points), moderate (3-6 points), and severe (7-10 points). Interobserver agreement for both the CT severity index and the presence of peripancreatic vascular abnormalities was calculated (K-statistic). Correlation between the prevalence of complications and the degree of pancreatitis was estimated using Fisher's exact test. Results: The severity of pancreatitis was graded as mild (n=59 scans), moderate (n=82 scans), and severe (n=18 scans). Venous abnormalities detected included splenic vein (SV) thrombosis (31 scans, 19 patients), superior mesenteric vein (SMV) thrombosis (20 scans, 14 patients), and portal vein (PV) thrombosis (17 scans, 13 patients). Arterial hemorrhage occurred in five patients (6 scans). In our series, no cases of arterial pseudoaneurysm formation were detected. The interobserver agreement range for scoring the degree of pancreatitis and the overall presence of major vascular abnormalities was 75.5-79.2 and 86.2-98.8%, respectively. The presence of the vascular abnormalities in correlation with the severity of pancreatitis was variable. Conclusion: Vascular abnormalities are relatively common CT findings in association with acute pancreatitis. The CT severity index is insufficiently accurate in predicting some of these complications since no statistically significant correlation between their prevalence and the severity of pancreatitis could be established

  12. The evaluation study of helical CT for hepatocellular carcinoma with microwave coagulation treatment

    International Nuclear Information System (INIS)

    Zheng Keguo; Xu Dasheng; Xie Xiaoyan; Peng Zhenpeng

    2002-01-01

    Objective: To study the helical CT signs of the hepatocellular carcinoma (HCC) after percutaneous microwave coagulation therapy (PMCT) and to evaluate the correlation between the helical CT signs and the therapeutic effect of HCC. Methods: The helical CT signs were analyzed in 22 cases with 26 lesions of the hepatocellular carcinoma that were treated with PMCT under ultrasonic guidance. Results: In 21 lesions, no enhancement was detected in the lesion border or inside the lesion at hepatic arterial phase (HAP) and portal venous phase (PVP). In 7 lesions, the slight or marked patchy enhancement was revealed in the surrounding liver of the lesions in HAP. In 5 lesions, nodular enhancement was found in the lesion border or inside the lesion in HAP. Conclusion: The dual-phase helical CT might be accurate in judging the therapeutic effect of HCC after PMCT. If no enhancement was showed in the lesions in the dual-phase helical CT, it indicated that no tumor survived. If slight or marked patchy pattern enhancement was revealed in the surrounding liver of the lesions in HAP, it was a normal reaction after PMCT. If nodular enhancement was found in the lesion border or inside the lesion in HAP, it indicated that the tumor partially survived

  13. Helical CT in acute lower gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Ernst, Olivier; Leroy, Christophe; Sergent, Geraldine; Bulois, Philippe; Saint-Drenant, Sophie; Paris, Jean-Claude

    2003-01-01

    The purpose of this study was to assess the usefulness of helical CT in depicting the location of acute lower gastrointestinal bleeding. A three-phase helical CT of the abdomen was performed in 24 patients referred for acute lower gastrointestinal bleeding. The diagnosis of the bleeding site was established by CT when there was at least one of the following criteria: spontaneous hyperdensity of the peribowel fat; contrast enhancement of the bowel wall; vascular extravasation of the contrast medium; thickening of the bowel wall; polyp or tumor; or vascular dilation. Diverticula alone were not enough to locate the bleeding site. The results of CT were compared with the diagnosis obtained by colonoscopy, enteroscopy, or surgery. A definite diagnosis was made in 19 patients. The bleeding site was located in the small bowel in 5 patients and the colon in 14 patients. The CT correctly located 4 small bowel hemorrhages and 11 colonic hemorrhages. Diagnosis of the primary lesion responsible for the bleeding was made in 10 patients. Our results suggest that helical CT could be a good diagnostic tool in acute lower gastrointestinal bleeding to help the physician to diagnose the bleeding site. (orig.)

  14. Helical CT appearance of hypovascular small hepatocellular carcinoma with pathologic correlation

    International Nuclear Information System (INIS)

    Zheng Keguo; Xu Dasheng; Shen Jingxian

    2003-01-01

    Objective: To study the helical CT dual-phase enhancement manifestation of the hypodense small hepatocellular carcinoma, and to evaluate its correlation with the histopathology. Methods: The CT signs and its histopathologic changes were analyzed in 25 cases with 27 hypodense lesions in helical CT dual-phase enhancement. All the lesions were confirmed as small hepatocellular carcinoma by operation and histopathology. Results: (1) On unenhanced scan, 16 lesions were with obscure borders and 11 lesions were with well-delineated borders. On enhanced scan, only 7 lesions were with obscure borders and the other 20 lesions were with well-delineated borders, and their contours were slightly irregular. (2) On unenhanced scan, 18 lesions showed homogeneous hypodensity and 9 lesions showed heterogeneous hypodensity. On enhanced scan, only 6 lesions showed homogeneous hypodensity and the other 21 lesions showed heterogeneous hypodensity with multiple flecks of more hypodense areas. Conclusion: The helical CT dual-phase enhancement characteristic manifestations of hypodense small hepatocellular carcinoma were as follows: the border of the lesion was obscure on unenhanced scan, however the border of the lesion became well-delineated and slightly irregular, and there were multiple flecks of more hypodense areas in the lesions after enhancement. This might be an important character in distinguishing hypodense small hepatocellular carcinoma from other hypodense diseases in the liver

  15. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  16. Helical CT of traumatic injuries of the thoracic aorta

    International Nuclear Information System (INIS)

    Mengozzi, E.; Burzi, M.; Miceli, M.; Lipparini, M.; Sartoni Galloni, S.

    2000-01-01

    Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a previous baseline study, contrast-enhanced scans were acquired with pitch 1 in 87 patients. Helical CT showed aortic lesions in 9 of 256 patients examined. In all the 9 cases it was found a mediastinal hematoma and all of them had positive plain chest radiographic findings of mediastinal enlargement. Moreover, in 6 cases aortic knob blurring was also evident on plain chest film and in 5 cases depressed left mainstem bronchus and trachea deviation rightwards were observed. All aortic lesions were identified on axial scans and located at the isthmus of level. Aortic rupture was always depicted as pseudo diverticulum of the proximal descending tract and intimal flap. It was also found that periaortic hematoma in 6 cases and intramural hematoma in 1 case. There were non false positive results in the series: 7 patients with Helical CT diagnosis of aortic rupture were submitted to conventional aortography that confirmed both type and extension of the lesions as detected by Helical CT, and all findings were

  17. Helical CT finding of carotid-cavernous fistula: a sign of early enhancing superior ophthalmic vein

    International Nuclear Information System (INIS)

    Kim, Jae Hyung; Na, Dong Gyu; Byun, Hong Sik; Ryoo, Jae Wook

    2000-01-01

    The purpose of this study was to determine the diagnostic value of a sign of early enhancing superior ophthalmic vein (SOV), as seen on helical CT images in patients with carotid-cavernous fistula (CCF). This study involved 16 patients with CCF and 28 control patients. Axial CT images with scanning delays of 30 seconds following bolus injection of contrast material (90 mL, 3 mL/sec) were obtained, and this procedure was followed by coronal CT imaging. To determine the presence or absence of early enhancement or, dilatation of the SOV, bulging of the cavernous sinus, and enlargement of extraocular muscle, CT images were analysed by three observers in a blinded, random manner. Early enhancement of SOV was determined to be present where enhancement of the SOV was similar to or stronger than that of the ipsilateral posterior cerebral artery. A sign of early enhancing SOV was seen in 14 of the 16 patients with CCF but in no control patients (88% sensitivity and 100% specificity). The respective sensitivity and specificity of other CT features were 71% and 100% (dilatation of the SOV, as seen on axial images), 60% and 83% (dilatation of the SOV, as seen on coronal images), 71% and 89% (dilatation of the cavernous sinus), and 65% and 98% (enlargement of extraocular muscle). A sign of early enhancing SOV is a characteristic and specific CT finding of CCF, and is useful for the diagnosis of CCF. (author)

  18. Optimized enhancement in helical CT: Experiences with a real-time bolus tracking system in 628 patients

    International Nuclear Information System (INIS)

    Kirchner, J.; Kickuth, R.; Laufer, U.; Noack, M.; Liermann, D.

    2000-01-01

    AIMS: Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. MATERIALS AND METHODS: In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. RESULTS: There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). CONCLUSION: Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Kirchner, J. (2000). Clinical Radiology 55, 368-373

  19. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    Science.gov (United States)

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  20. Identification of the segmental artery feeding the anterior spinal artery. Correlation between helical CT and angiography

    International Nuclear Information System (INIS)

    Nishimura, Jun-ichi; Lee, Jin; Koike, Shigeomi

    2005-01-01

    We investigated whether identification of the segmental artery feeding the anterior spinal artery (ASA) is possible by single-slice helical CT. Enhanced CT and angiography were performed in 14 patients with retroperitoneal, liver, or bone tumor. A single-slice helical CT scanner with 7 mm collimation and a 1.0 helical pitch was used. Scanning was started 25 to 30 sec after an intravenous injection of 100 ml of contrast medium at a rate of 3.0 ml/sec. We predicted the segmental artery feeding the ASA in all 14 patients using enhanced CT images. In 12 of the 14 patients, the segmental artery feeding the ASA was angiographically identified. In 7 of these 12 patients, the level of the segmental artery feeding the ASA identified on segmental arteriogram was the same level as that predicted by enhanced CT. In the remaining 5 patients, the level of the segmental artery feeding the ASA identified on segmental arteriogram was one level higher or lower than the predicted spinal level. We could identify the segmental artery feeding the ASA by detailed examination and interpretation of single-slice helical CT images. (author)

  1. Dual phase helical CT: diagnosis value for early pancreatic carcinoma

    International Nuclear Information System (INIS)

    Shen Bingqi; Zhang Ling; Zheng Keguo; Xu Dasheng

    2006-01-01

    Objective: To study dual-phase helical CT for the evaluation of early pancreatic cacinoma. Methods: Dual-phase helical CT was performed on 21 patients with early pancreatic carcinoma. In the enhanced imaging the contrast material was intravenously injected in a dose of 1.5 ml/kg at a rate of 3 ml/s. The image acquisition of the lesion in pancreatic phase (PP) and portal venous phase (PVP) were started at 35 seconds and 65 seconds after the start of the injection respectively. The enhancement of normal pancreas and tumor during the two phases was observed and compared. All data were statistically analyzed. Results: Tumor-pancreas contrast was significantly greater in PP (45.16±113.23) HU than in PVP (23.15±12.44) HU (t=2.13, P<0.01). Conclusion: Dual-phase helical CT scan for pancreas, including the imaging of the pancreatic and portal , venous phase, can be applied as an optimal selection. It can delineate early pancreatic carcinoma clearly and provide more information for the diagnosis of the lesion. The tumor-pancreas contrast was much higher' in PP than in PVP. (authors)

  2. Role of contrast-enhanced helical CT in the evaluation of acute thoracic aortic injuries after blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, M.; Pinto, A.; Pinto, F.; Romano, L.; Ragozzino, A.; Grassi, R.

    2001-01-01

    The purpose of this retrospective study was to determine the value of contrast-enhanced helical CT for detecting and managing acute thoracic aortic injury (ATAI). Between June 1995 and February 2000, 1419 consecutive chest CT examinations were performed in the setting of major blunt trauma. The following CT findings were considered indicative of ATAI: intimal flap; pseudoaneurysm; contour irregularity; lumen abnormality; and extravasation of contrast material. On the basis of these direct findings no further diagnostic investigations were performed. Isolated mediastinal hematoma on CT scans was considered an indirect sign of ATAI: In these cases, thoracic aortography was performed even if CT indicated normal aorta. Seventy-seven patients had abnormal CT scans: Among the 23 patients with direct CT signs, acute thoracic aortic injuries was confirmed at thoracotomy in 21. Two false-positive cases were observed. The 54 remaining patients had isolated mediastinal hematoma without aortic injuries at CT and corresponding negative angiograms. The 1342 patients with negative CT scans were included in the 8-month follow-up program and did not show any adverse sequela based on clinical and radiographic criteria. Contrast-enhanced helical CT has a critical role in the exclusion of thoracic aortic injuries in patient with major blunt chest trauma and prevents unnecessary thoracic aortography. Direct CT signs of ATAI do not require further diagnostic investigations to confirm the diagnosis: Isolated aortic bands or contour vessel abnormalities should be first considered as possible artifacts or related to non-traumatic etiologies especially when mediastinal hematoma is absent. In cases of isolated mediastinal hematoma other possible sources of bleeding should be considered before directing patients to thoracic aortography. (orig.)

  3. Aortic non communicating dissections. A study with helical CT

    International Nuclear Information System (INIS)

    Midiri, M.; Strada, A.; Stabile Ianora, A.A.; Rotondo, A.; Angelelli, G.; D'Agostino, D.; De Luca Tupputi Schinosa, L.

    2000-01-01

    The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low density on enhanced images in all patients. Thickening was eccentric in 14/18 patients and concentric in 4/18 only; it always exceeded 4 mm. It was found some intimal calcifications in 8 patients and hemo thorax and/or hemo mediastinum in 9 patients. A patient with type A hematoma died of cardiac tamponade a few hours after CT diagnosis. Six patients (5 type B and 1 type A) underwent anti-hypertensive treatment and radiological follow-up. Eleven patients (6 type A and 5 type B) underwent prosthesis replacement and 5 of them (3 type A and 2 type B) died of postoperative complications. In the 5 type B patients surgery was performed because of treatment-resistant pain and of the onset of ischemic complications to abdominal organs caused by involvement of the main collateral branches of the aorta. One patient with type A hematoma was submitted to drug treatment because it was judged unresectable. Intramural hematoma of the aorta is a distinct pathological entity, which should not be

  4. Helical CT of ureteral disease

    International Nuclear Information System (INIS)

    Cikman, Pablo; Bengio, Ruben; Bulacio, Javier; Zirulnik, Esteban; Garimaldi, Jorge

    2000-01-01

    Among the new applications of helical CT is the study of the ureteral pathology. The objective of this paper was to evaluate patients with suspected pathology of this organ and the repercussion in the therapeutic plans. We studied 23 patients with a helical CT protocol, without IV contrast injection and performed multiplanar reconstruction (MPR). We called this procedure Pielo CT. Thirteen ureteral stones were detected, 6 calculi, 2 urinary tract tumors, dilatation of the system in a patient with neo-bladder. In 2 patients, in whom ureteral pathology was ruled out, we found other alterations that explained the symptoms, (gallbladder stones, disk protrusion). The Pielo CT let decide a therapeutical approach in 20 or 21 patients with ureteral pathology. (author)

  5. Pancreatic adenocarcinoma: dual-phase helical CT with surgical and histopathologic correlation

    International Nuclear Information System (INIS)

    Kim, Eun A; Yoon, Kwon Ha; Park, Seong Hoon; Yun, Ki Jung; Won, Jong Jin

    2003-01-01

    To determine the accuracy of dual-phase helical CT in assessing the resectability of pancreatic ductal adenocarcinoma, and to correlate the CT findings with the surgical and histopathologic findings. Thirty patients with pathologically proven cancer of the pancreas underwent arterial-and portal-phase helical CT scanning, and in the two of these, single-level dynamic CT was performed during celiac and superior mesenteric arteriography. In 17 patients who underwent surgery for potentially resectable cancer of the pancreatic head, tumor resectability was assessed. The CT findings were analyzed and correlated with these of surgery and histopathology. In 13 (76%) of the 17 patients who underwent surgery, tumors were resectable. Their average size was 2.76 cm (arterial phase), 2.30 cm (portal phase), and 2.48 cm (pathologically determined) and the overall accuracy of helical CT for assessing resectability was 87%. In all patients, the central portion of the tumors exhibited hypoattenuation at both phases; the peripheral portion showed hypoattenuation at the arterial phase and iso- (n=10) or hyperattenuation (n=3) at the portal phase. Single-level dynamic CT depicted a persistently hypoattenuating central portion and progressive and prolonged enhancement of the periphery. CT-histopathologic correlation showed that central hypoattenuation indicated the presence of tumor cells, necrosis (n=3) and mucin (n=4), while the peripheral iso- or hyperattenuated areas seen at the portal phase represented fibrosis and inflammatory infiltration. Histopathologic examination revealed tumoral infiltration of peripancreatic fat tissue (n=11) and microvascular invasion of major peripancreatic vessels (n=7). The dual-phase helical CT is useful in the determination of resectability in pancreas cancer and CT findings represent well the histopathologic features of pancreas cancer

  6. Pancreatic adenocarcinoma: dual-phase helical CT with surgical and histopathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Park, Seong Hoon; Yun, Ki Jung; Won, Jong Jin [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2003-03-01

    To determine the accuracy of dual-phase helical CT in assessing the resectability of pancreatic ductal adenocarcinoma, and to correlate the CT findings with the surgical and histopathologic findings. Thirty patients with pathologically proven cancer of the pancreas underwent arterial-and portal-phase helical CT scanning, and in the two of these, single-level dynamic CT was performed during celiac and superior mesenteric arteriography. In 17 patients who underwent surgery for potentially resectable cancer of the pancreatic head, tumor resectability was assessed. The CT findings were analyzed and correlated with these of surgery and histopathology. In 13 (76%) of the 17 patients who underwent surgery, tumors were resectable. Their average size was 2.76 cm (arterial phase), 2.30 cm (portal phase), and 2.48 cm (pathologically determined) and the overall accuracy of helical CT for assessing resectability was 87%. In all patients, the central portion of the tumors exhibited hypoattenuation at both phases; the peripheral portion showed hypoattenuation at the arterial phase and iso- (n=10) or hyperattenuation (n=3) at the portal phase. Single-level dynamic CT depicted a persistently hypoattenuating central portion and progressive and prolonged enhancement of the periphery. CT-histopathologic correlation showed that central hypoattenuation indicated the presence of tumor cells, necrosis (n=3) and mucin (n=4), while the peripheral iso- or hyperattenuated areas seen at the portal phase represented fibrosis and inflammatory infiltration. Histopathologic examination revealed tumoral infiltration of peripancreatic fat tissue (n=11) and microvascular invasion of major peripancreatic vessels (n=7). The dual-phase helical CT is useful in the determination of resectability in pancreas cancer and CT findings represent well the histopathologic features of pancreas cancer.

  7. Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemo embolization

    International Nuclear Information System (INIS)

    Catalano, O.; Esposito, M.; Sandomenico, F.; Siani, A.; Nunziata, A.

    2000-01-01

    The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to globla chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower tha 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively homogeneous areas with hyperattenuation in the arterial phase and hypo-isoattenuation in the portal and/or delayed phase, or with hypo-isoattenuation in the arterial phase and in the portal and/or delayed phase. Lipiodol CT permitted to recognize 65 nodules (1-5/patient, mean 1.5), namely 15 grade I, 21 grade II, 20 grade III and 9 grade IV. Multiphase CT identified 6 additional nodules in 5 patients, 5 hypervascular and 1 hypovascular, and better assessed the correct morphology and volume of grade I nodules. Only 4 of 6 nodules missed on Lipiodol CT showed oily agent uptake after a new chemoembolization session. Moreover after retreatment, carried out in 6 of 9 patients with grade I uptake (11 nodules in all), it has been found persistence of the grade I pattern in 5 nodules, grade II in 5, and grade III in 1. Lipiodol CT may miss liver nodules and underestimate the volume of nodules with poor uptake. Though Lipiodol CT should still be considered slightly more sensitive than multiphase CT, in the general opinion this technique has

  8. Helical 3D-CT images of soft tissue tumors in the hand

    Energy Technology Data Exchange (ETDEWEB)

    Otani, Kazuhiro; Kikuchi, Hiraku; Tan, Akihiro; Hamanishi, Chiaki; Tanaka, Seisuke [Kinki Univ., Osaka-Sayama (Japan). School of Medicine

    2000-02-01

    X-ray, ultrasonograph CT, MRI and angiography are used to detect tumoral lesions. Recently, helical CT has been revealed to be a useful method for the diagnosis and preoperative evaluation of soft tissue tumors, by which high quality and accurate three dimensional (3D) images can be obtained quickly. We analyzed the preoperative 3D-CT images of soft tissue tumors in the hands of 11 cases (hemangioma in 6 cases, giant cell tumor, lipoma, angiofibroma, chondrosarcoma and malignant fibro-histiocytoma in one case each). Enhanced 3D-CT clearly visualized hemangiomas and solid tumors from the surrounding tissues. The tumors could easily be observed from any direction and color-coded according to the CT number. Helical 3D-CT was thus confirmed to be useful for the diagnosis and preoperative planning by indicating the details of tumor expansion into surrounding tissues. (author)

  9. Utility of three-dimensional helical CT in the diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Maeda, Yoshiaki; Hata, Yoshinobu; Matsuoka, Shinnichi; Nakajima, Nobuhisa; Ito, Toichi; Osada, Tadahiro; Sano, Fumio

    2004-01-01

    Although utility of three-dimensional (3D) helical CT for preoperative examination of breast cancer has been discussed, the accuracy of the helical CT in diagnosing breast cancer has not been fully evaluated. In this study 56 malignant and 28 benign breast tumors were evaluated preoperatively with 3D-helical CT, and their imaging results were compared with pathological findings of surgical specimens. Helical CT identified the presence of malignancy in 54 out of the 56 cancer cases tested and the sensitivity and specificity in distinguishing between malignant and benign tumors were 82% and 57%, respectively. The sensitivity and specificity in diagnosing the presence of metastatic axillary lymph nodes using helical CT were 70% and 80%, respectively. The sensitivity and specificity in diagnosing the presence of extensive intraductal component (EIC) using helical CT were 71% and 86%, respectively. Helical CT visualized all of the tumors in multifocal breast cancer cases. In conclusion, 3D-helical CT is a useful modality for preoperative examination of breast cancer, especially for assessing axillary lymph node status, and EIC, and will be helpful for conducting sentinel lymph node biopsy (SNLB) and breast-conserving surgery. (author)

  10. Multislice helical CT in the diagnosis of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Yang Li; Zhao Shaohong; Nie Yongkang; Zhao Hong; Fang Jie; Cai Zulong; Yang Zhou; Ying Yifeng

    2005-01-01

    Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in 60 s phase of contrast enhancement scans, respectively ( P < 0105 ) 1 The tumor involving the bile duct was enhanced most remarkablely on 25 s phase, and the bile duct wall thickening, bile duct narrowing or occlusion were demonstrated as the p rimary findings of hilar cholangiocarcinoma1 The intraductal sp read of tumor could be demonstrated as small nodules on the bile duct wall p roximal or distal to the tumor1 Conclusion. The tumor involving the bile duct can be enhanced most remarkablely on 25 s phase after contrast injection1 Multislice helical CT, especially 3D reconstructed images, can be used to detect the direct findings of hilar cholangiocarcinomas and the extension of tumor involving the bile duct. (authors)

  11. Helical CT in evaluation of the bronchial tree

    International Nuclear Information System (INIS)

    Perhomaa, M.; Laehde, S.; Rossi, O.; Suramo, I.

    1997-01-01

    Purpose: To establish a protocol for and to assess the value of helical CT in the imaging of the bronchial tree. Material and Methods: Noncontrast helical CT was performed in 30 patients undergoing fiberoptic bronchoscopy for different reasons. Different protocols were compared; they included overlapping 10 mm, 5 mm, or 3 mm slices and non-tilted, cephalad or caudal tilted images. Ordinary cross-sectional and multiplanar 2D reformats were applied for visualization of the bronchial branches. The effect of increasing the helical pitch was tested in one patient. Results: A total of 92.1-100% of the segmental bronchi present in the helical acquisitions were identified by the different protocols. The collimation had no significant impact on the identification of the bronchial branches, but utilization of 3-mm overlapping slices made it easier to distinguish the nearby branches and provided better longitudinal visualization of the bronchi in 2D reformats. The tilted scans illustrated the disadvantage of not covering all segmental bronchi in one breath-hold. An increase of the pitch from 1 to 1.5 did not cause noticeable blurring of the images. CT and bronchoscopic findings correlated well in the area accessible to bronchoscopy, but CT detected 5 additional pathological lesions (including 2 cancers) in the peripheral lung. Conclusion: Helical CT supplemented with bronchography-like 2D reformats provides an effective method complementary to bronchoscopy in the examination of the bronchial tree. (orig.)

  12. Helical CT of congenital ossicular anomalies

    International Nuclear Information System (INIS)

    Osada, Hisato; Machida, Kikuo; Honda, Norinari

    2001-01-01

    Since January 1996 to December 2000, 26 cases of congenital ossicular anomaly could be diagnosed with helical CT. All cases were unilateral. In 8 patients with malformation of the external ear, CT showed malleoincudal fixation (n=5), malleoincudal fixation and deformed incuts long process (n=1), deformed incus long process (n=1), and partial fusion of malleus neck and incus long process (n=1). In 18 patients with normal external ear, CT showed defect of the incus long process (n=5), defect of both the incus long process and stapes superstructure (n=8, 2 patients with congenital cholesteatoma, 1 with hypoplastic oval window), defect of the stapes superstructure (n=2, 1 patient with oval window absence), defect of the malleus manubrium (n=1), ossification of the stampede's tendon (n=1), and monopod stapes (n=1). Helical CT can evaluate the auditory ossicular chain in detail and is useful for diagnosing congenital ossicular anomaly. (author)

  13. Helical CT in the primary trauma evaluation of the cervical spine: an evidence-based approach

    Energy Technology Data Exchange (ETDEWEB)

    Blackmore, C.C. [Washington Univ., Seattle, WA (United States). Dept. of Radiology; Center for Cost and Outcomes Research, Univ. of Washington, Seattle (United States); Dept. of Radiology, Harborview Medical Center, Seattle, WA (United States); Mann, F.A. [Washington Univ., Seattle, WA (United States). Dept. of Radiology; Harborview Injury Prevention and Research Center, University of Washington, Seattle (United States); Wilson, A.J. [Washington Univ., Seattle, WA (United States). Dept. of Radiology

    2000-11-01

    This review provides a summary of the cost-effectiveness, clinical utility, performance, and interpretation of screening helical cervical spine CT for trauma patients. Recent evidence supports the use of helical CT as a cost-effective method for screening the cervical spine in high-risk trauma patients. Screening cervical spine CT can be performed at the time of head CT to lower the cost of the evaluation, and when all short- and long-term costs are considered, CT may actually save money when compared with traditional radiographic screening. In addition to having higher sensitivity and specificity for cervical spine injury, CT screening also allows more rapid radiological clearance of the cervical spine than radiography. Patients who are involved in high-energy trauma, who sustain head injury, or who have neurological deficits are candidates for CT screening. Screening with CT may enhance detection of other potentially important injuries of the cervical region. (orig.)

  14. Unusual presentation of a pancreatic insulinoma in helical CT and dynamic contrast-enhanced MR imaging: case report

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, A.; Arias, M.; Brasa, J. [Unidad de Resonancia Magnetica (Medtec), Hospital Xeral-Cies, Vigo (Spain); Casal, M. [Unidad de Radiologia Intervencionista, Hospital Xeral-Cies, Vigo (Spain); Paramo, C. [Servicio de Endocrinologia, Hospital Xeral-Cies, Vigo (Spain); Fiano, C. [Servicio de Anatomia Patologica, Hospital Xeral-Cies, Vigo (Spain)

    2001-06-01

    Insulinomas are pancreatic neoplasms that can be radiologically characterized typically because of their tendency to present intense and early contrast enhancement with a wash-out phenomenon. In this sense, we report an unusual case of a hypovascular solid pancreatic insulinoma confirmed with surgery and pathologic analysis, in a patient with normal serum insulin levels. In the two-phase helical CT, the mass behaved as a hypodense lesion with respect to the surrounding pancreatic parenchyma during the arterial phase and as a hypointense lesion during the dynamic contrast-enhanced MR imaging. Pathologic examination demonstrated a hypercellular tumor with poor vascularization of intervening stroma which showed prominent amyloid deposits. (orig.)

  15. Unusual presentation of a pancreatic insulinoma in helical CT and dynamic contrast-enhanced MR imaging: case report

    International Nuclear Information System (INIS)

    Iglesias, A.; Arias, M.; Brasa, J.; Casal, M.; Paramo, C.; Fiano, C.

    2001-01-01

    Insulinomas are pancreatic neoplasms that can be radiologically characterized typically because of their tendency to present intense and early contrast enhancement with a wash-out phenomenon. In this sense, we report an unusual case of a hypovascular solid pancreatic insulinoma confirmed with surgery and pathologic analysis, in a patient with normal serum insulin levels. In the two-phase helical CT, the mass behaved as a hypodense lesion with respect to the surrounding pancreatic parenchyma during the arterial phase and as a hypointense lesion during the dynamic contrast-enhanced MR imaging. Pathologic examination demonstrated a hypercellular tumor with poor vascularization of intervening stroma which showed prominent amyloid deposits. (orig.)

  16. Colonic metastasis from renal cell carcinoma: helical-CT demonstration

    International Nuclear Information System (INIS)

    Diaz-Candamio, M.J.; Pombo, S.; Pombo, F.

    2000-01-01

    Clinically evident colonic metastasis from renal cell carcinoma (RCC) is rare. In the present study a hypervascular sigmoid mass was demonstrated on arterial-phase helical CT using a water enema in a patient who had suffered left nephrectomy 8 years previously for RCC. The intense and early enhancement of the lesion suggested the possibility of a solitary colonic metastasis from RCC, a diagnosis which was pathologically confirmed. (orig.)

  17. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  18. Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT

    International Nuclear Information System (INIS)

    Johnston, Jennifer H.; Podberesky, Daniel J.; Larson, David B.; Alsip, Christopher; Yoshizumi, Terry T.; Angel, Erin; Barelli, Alessandra; Toncheva, Greta; Egelhoff, John C.; Anderson-Evans, Colin; Nguyen, Giao B.; Frush, Donald P.; Salisbury, Shelia R.

    2013-01-01

    Advanced multidetector CT systems facilitate volumetric image acquisition, which offers theoretic dose savings over helical acquisition with shorter scan times. Compare effective dose (ED), scan duration and image noise using 320- and 64-detector CT scanners in various acquisition modes for clinical chest, abdomen and pelvis protocols. ED and scan durations were determined for 64-detector helical, 160-detector helical and volume modes under chest, abdomen and pelvis protocols on 320-detector CT with adaptive collimation and 64-detector helical mode on 64-detector CT without adaptive collimation in a phantom representing a 5-year-old child. Noise was measured as standard deviation of Hounsfield units. Compared to 64-detector helical CT, all acquisition modes on 320-detector CT resulted in lower ED and scan durations. Dose savings were greater for chest (27-46%) than abdomen/pelvis (18-28%) and chest/abdomen/pelvis imaging (8-14%). Noise was similar across scanning modes, although some protocols on 320-detector CT produced slightly higher noise. Dose savings can be achieved for chest, abdomen/pelvis and chest/abdomen/pelvis examinations on 320-detector CT compared to helical acquisition on 64-detector CT, with shorter scan durations. Although noise differences between some modes reached statistical significance, this is of doubtful diagnostic significance and will be studied further in a clinical setting. (orig.)

  19. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine

    2001-10-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  20. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    International Nuclear Information System (INIS)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko

    2001-01-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  1. Budd-Chiari syndrome: dynamic enhancement findings with multi-slice helical CT and CT angiography analysis

    International Nuclear Information System (INIS)

    Meng Xiaochun; Shan Hong; Zhu Kangshun; Xu Chuan; Zhang Jiansheng; Liu Lingyun; Ye Binbin

    2005-01-01

    Objective: To investigate the dynamic enhancement regulations of liver and their mechanism in Budd-Chiari syndrome (BCS) by using multi-slice CT and evaluate the value of CT angiography in the diagnosis of BCS. Methods: 28 cases with BCS confirmed by digital subtraction angiography (DSA) were retrospectively analyzed. All patients underwent dynamic enhancement examinations with multi-slice CT within 1 week before DSA. The relevant vessels were reconstructed respectively with MIP, VR and MPR. Compared with the results of DSA, we analyzed the dynamic enhancement regulations of liver in BCS, estimated the value of dynamic enhancement CT exams and CTA techniques in judging the obstruction level and showing collateral vessels. Results: Of all 28 cases, CT correctly showed the obstruction level in 26 cases, and 2 had incorrect results which proved to be membranous obstruction of the inferior vena cava superior to diaphragm. In 22 cases with hepatic vein obstructions, hepatic parenchyma displayed typical patchy enhancement in 19, atypical patchy enhancement in 3.8 cases among these showed benign nodules. Simultaneously, CT showed stenosis and rigidity of portal vein branches in 20, enlargement of hepatic artery in 14, hepatic collateral vessels in 20 out of 22 cases. In 6 cases with simple obstruction of inferior vena cava, hepatic changes were not found. Collateral circulations in or out of liver corresponded to the obstruction level. Conclusion: Dynamic enhancement examinations with multi-slice CT can correctly reflect the hepatic hemodynamic changes. Transverse images, combined with CTA, can explicitly display the obstruction level of vascular lesions and collateral circulations in BCS. (authors)

  2. Rupture of an aneurysm of the coronary sinus of Valsalva: diagnosis by helical CT angiography

    International Nuclear Information System (INIS)

    Azarine, A.; Lions, C.; Beregi, J.P.; Koussa, M.

    2001-01-01

    A 75-year-old man presented with a 5-day history of upper chest discomfort. On auscultation, there was a systolic murmur in the left parasternal area that radiated to the apex. Electrocardiography showed flat T waves in the anterior precordial leads. Chest X ray revealed mediastinal enlargement. Transthoracic echocardiography showed a dilated proximal ascending aorta with moderate aortic regurgitation. A contrast-enhanced helical CT scan, performed to eliminate an aortic dissection, showed a ruptured left coronary sinus of Valsalva aneurysm, confirmed at surgery. This case highlights the fact that helical CT, in patients with suspected aortic dissection, may reveal other pathology that accounts for the clinical presentation. (orig.)

  3. Rupture of an aneurysm of the coronary sinus of Valsalva: diagnosis by helical CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Azarine, A.; Lions, C.; Beregi, J.P. [Dept. of Vascular Surgery, Hopital Cardiologique, CHRU de Lille (France); Koussa, M. [Dept. of Vascular Radiology, Hopital Cardiologique, CHRU de Lille (France)

    2001-08-01

    A 75-year-old man presented with a 5-day history of upper chest discomfort. On auscultation, there was a systolic murmur in the left parasternal area that radiated to the apex. Electrocardiography showed flat T waves in the anterior precordial leads. Chest X ray revealed mediastinal enlargement. Transthoracic echocardiography showed a dilated proximal ascending aorta with moderate aortic regurgitation. A contrast-enhanced helical CT scan, performed to eliminate an aortic dissection, showed a ruptured left coronary sinus of Valsalva aneurysm, confirmed at surgery. This case highlights the fact that helical CT, in patients with suspected aortic dissection, may reveal other pathology that accounts for the clinical presentation. (orig.)

  4. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong

    2004-01-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases

  5. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2004-08-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases.

  6. Adenocarcinoma of the pancreatic head: preoperative helical CT. Criteria of resectability

    International Nuclear Information System (INIS)

    Kozima, Shigeru; Szelagowski, Carlos; Tisserand, Guy L.; Ocampo, Carlos; Zandalazini, Hugo; Silva, Walter; Oria, Alejandro; Vidovic, Gustavo; Varas, Pablo

    2001-01-01

    Objective: The purpose of this study is to determine the accuracy of biphasic helical CT scanning in predicting resectability of adenocarcinoma of the head of the pancreas by staying tumor involvement of the portal and superior mesenteric veins. Material and methods: 46 patients with proven adenocarcinoma of the head of the pancreas who underwent curative or palliative surgery were studied with preoperative biphasic helical CT scanning. Tumor involvement of the portal and mesenteric veins was graduated on a 1-3 scale based on circumferential contiguity of the tumor vessel. Grade 1: without contact; grade 2: tumor involvement of less than 50% of the vessel; grade 3: tumor involvement of more than 50%. Results: The total number of vessels evaluated was 92. In our series the preoperative biphasic helical CT was accurate in 77% for resectability and unresectability. Conclusion: Our experience of staging in 3 grades with biphasic helical CT, vessel involvement the portal and superior mesenteric veins of adenocarcinoma of the head of the pancreas is highly specific for unresectable tumor in patients who were graded 2 and 3. (author)

  7. Helical CT scan for emergent patients with cerebrovascular diseases

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio

    1995-01-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author)

  8. Helical CT scan for emergent patients with cerebrovascular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio [Fukushima Medical Coll. (Japan)

    1995-08-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author).

  9. Utility of bolus dynamic CT for the detection of hypervascular malignant hepatic tumors. Mainly referring to the comparison with delayed phase contrast-enhanced CT

    International Nuclear Information System (INIS)

    Matsuda, Hiromichi; Abe, Kimihiko; Freeny, P.C.

    1996-01-01

    In order to analyze the usefulness of dynamic contrast-enhanced CT, 84 patients who had hepatocellular carcinoma or suspected hypervascular metastases were studied with conventional incremental dynamic CT (CID-CT) or double helical CT (DH-CT). Delayed phase contrast-enhanced CT studies were consecutively performed in all patients. Thirty-six of 84 patients had malignant hepatic neoplasms; six had hepatocellular carcinoma and 30 had metastatic tumors. At first, the detectability of hepatic lesions was evaluated with bolus dynamic CT and delayed phase CT. Dynamic CT has detected more lesions than delayed CT. Some hepatic lesions described as isodensity were missed on CID-CT. Therefore, delayed phase CT cannot be eliminated when CID-CT is performed. Secondly, hepatic lesion detectability with CID-CT was compared with that of DH-CT. DH-CT did not miss the hepatic lesions picked up by delayed phase CT and was expected to provide excellent detectability of hypervascular hepatic neoplasms. In addition, first helical CT showed most hepatic lesions as areas of obvious hyperdensity, while CID-CT did not show their correct vascularities. So-called hypervascular hepatic tumors, however, were not always hypervascular and were demonstrated as areas of iso-hypodensity even on initial helical scanning. Second helical CT was useful to detect these so-called hypervascular, but actually hypovascular lesions. In conclusion, dynamic CT was helpful in detecting hypervascular hepatic malignant neoplasms, and DH-CT was more accurate than-CID-CT for the detection of hepatic lesions and the evaluation of vascular lesion. (author)

  10. Diagnosis of nutcracker syndrome of the left renal vein. Value of the corticomedullary phase of helical CT

    International Nuclear Information System (INIS)

    Igari, Hidenori

    2001-01-01

    The clinical significance of the corticomedullary phase of helical CT in the diagnosis of nutcracker syndrome of the left renal vein (LRV) was evaluated. A total of 38 patients with hematuria of unknown origin (12 men and 26 women, mean age 24 years [range: 18-32 years]) were examined by helical CT of the kidneys, retrograde left renal venography, and measurement of renocaval pressure gradients. The sensitivity and specificity of the corticomedullary and nephrographic phases of helical CT for detecting the nutcracker syndrome were determined. The nutcracker syndrome was diagnosed on the basis of the renography findings combined with pressure measurements in 19 patients: 12 with LRV hypertension and collateral veins, 1 with hypertension and no collateral veins, and 6 with collateral veins and normal pressure gradients or borderline hypertension. Both the corticomedullary- and nephrographic-phase images revealed distended LRVs in 26 (68%) of the 38 patients. The LRV mean attenuation values in the corticomedullary phase (164±22 Hounsfield units [H], range: 138-209 H) was significantly greater (p<0.001) than in the nephrographic phase (80±14 H, range: 62-100 H). During the corticomedullary phase, opacified blood from the renal vein was mixed with unopacified blood in the IVC. In the nephrographic phase, however, the IVC was enhanced homogeneously, but only slightly. Corticomedullary-phase imaging detected collateral veins that exhibited early enhancement, indicating retrograde flow from the LRVs in 15 out of 18 patients (83% of those with collateral veins), while the nephrographic-phase imaging revealed collateral veins in 8 patients (44% of those with collateral veins). The sensitivity and specificity of the corticomedullary-phase scan for detecting the nutcracker syndrome were 79% and 100%, respectively, as opposed to 42% and 100%, respectively, for the nephrographic phase. Retrograde flow from the LRV into the collateral veins in the corticomedullary phase is a

  11. Single-slice rebinning method for helical cone-beam CT

    International Nuclear Information System (INIS)

    Noo, F.; Defrise, M.; Clackdoyle, R.

    1999-01-01

    In this paper, we present reconstruction results from helical cone-beam CT data, obtained using a simple and fast algorithm, which we call the CB-SSRB algorithm. This algorithm combines the single-slice rebinning method of PET imaging with the weighting schemes of spiral CT algorithms. The reconstruction is approximate but can be performed using 2D multislice fan-beam filtered backprojection. The quality of the results is surprisingly good, and far exceeds what one might expect, even when the pitch of the helix is large. In particular, with this algorithm comparable quality is obtained using helical cone-beam data with a normalized pitch of 10 to that obtained using standard spiral CT reconstruction with a normalized pitch of 2. (author)

  12. Angiomyolipoma with minimal fat: Differentiation from papillary renal cell carcinoma by helical CT

    International Nuclear Information System (INIS)

    Zhang, Y.-Y.; Luo, S.; Liu, Y.; Xu, R.-T.

    2013-01-01

    Aim: To evaluate whether helical computed tomography (CT) images can be used to differentiate angiomyolipomas (AMLs) with minimal fat from papillary renal cell carcinomas (PRCCs) based on their morphological characteristics and enhancement features. Materials and methods: This retrospective study was approved by the institutional review board. Informed consent was waived. Forty-four patients (21 with AMLs with minimal fat and 23 with PRCCs) who underwent enhanced helical CT before total or partial nephrectomy were included. Two radiologists, who were blinded to the histopathology results, read the CT images and recorded the attenuation value, morphological characteristics, and enhancement features of the tumours, which were subsequently evaluated. An independent samples t-test, χ 2 test, and rank sum test were performed between the tumours. The predictive value of a CT finding was determined by multivariate logistic regression analysis. Results: AML with minimal fat had an apparent female prevalence (p < 0.01). Intra-tumoural vessels were noted in 11 cases of AML with minimal fat and three PRCC cases (p < 0.01). The unenhanced attenuation characteristic was significantly different between the two diseases (p < 0.001). The absolute attenuation values (AAVs) and the corrected attenuation values (CAVs) of the AML with minimal fat group of unenhanced and two phases of enhanced images were greater compared with that of the PRCC group (p < 0.05). After contrast medium injection, the tumour enhancement value (TEV) of the AML with minimal fat group in the corticomedullary phase was greater than that of the PRCC group (p < 0.01). Most cases of both tumour types demonstrated early enhancement characteristics; the enhancement value of the AML with minimal fat group was greater compared with that of the PRCC group (p < 0.01). The unenhanced attenuation characteristic, intra-tumoural vessels, and CAVs of unenhanced and early excretory phase scans were valuable parameters to

  13. Clinical application of the helical CT in patients who are unable to hold their breath

    International Nuclear Information System (INIS)

    Toyama, Yoshihiro; Kimura, Naruhide; Ohkawa, Motoomi; Tanabe, Masatada.

    1997-01-01

    We performed helical CT in eighteen patients who were unable to hold their breath for 10 chest and 8 abdominal regions. Although there were respiratory artifacts in three cases, we could obtain the useful clinical information in all cases. In our experimental examinations, CT value of the phantom by helical scan was lower than that by conventional scan without movement of the phantom. With movement of it, the CT value was further lowered by either scan method, but the lowered rate was smaller by helical scan as the movement becomes faster. We consider that helical CT can be applied to patients who were unable to hold their breath. (author)

  14. Partial volume and aliasing artefacts in helical cone-beam CT

    International Nuclear Information System (INIS)

    Zou Yu; Sidky, Emil Y; Pan, Xiaochuan

    2004-01-01

    A generalization of the quasi-exact algorithms of Kudo et al (2000 IEEE Trans. Med. Imaging 19 902-21) is developed that allows for data acquisition in a 'practical' frame for clinical diagnostic helical, cone-beam computed tomography (CT). The algorithm is investigated using data that model nonlinear partial volume averaging. This investigation leads to an understanding of aliasing artefacts in helical, cone-beam CT image reconstruction. An ad hoc scheme is proposed to mitigate artefacts due to the nonlinear partial volume and aliasing artefacts

  15. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT

    International Nuclear Information System (INIS)

    Kloeppel, R.; Kahn, T.; Schreiter, D.; Dietrich, J.; Josten, C.

    2002-01-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of ∼30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by ∼4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [de

  16. A rigid motion correction method for helical computed tomography (CT)

    International Nuclear Information System (INIS)

    Kim, J-H; Kyme, A; Fulton, R; Nuyts, J; Kuncic, Z

    2015-01-01

    We propose a method to compensate for six degree-of-freedom rigid motion in helical CT of the head. The method is demonstrated in simulations and in helical scans performed on a 16-slice CT scanner. Scans of a Hoffman brain phantom were acquired while an optical motion tracking system recorded the motion of the bed and the phantom. Motion correction was performed by restoring projection consistency using data from the motion tracking system, and reconstructing with an iterative fully 3D algorithm. Motion correction accuracy was evaluated by comparing reconstructed images with a stationary reference scan. We also investigated the effects on accuracy of tracker sampling rate, measurement jitter, interpolation of tracker measurements, and the synchronization of motion data and CT projections. After optimization of these aspects, motion corrected images corresponded remarkably closely to images of the stationary phantom with correlation and similarity coefficients both above 0.9. We performed a simulation study using volunteer head motion and found similarly that our method is capable of compensating effectively for realistic human head movements. To the best of our knowledge, this is the first practical demonstration of generalized rigid motion correction in helical CT. Its clinical value, which we have yet to explore, may be significant. For example it could reduce the necessity for repeat scans and resource-intensive anesthetic and sedation procedures in patient groups prone to motion, such as young children. It is not only applicable to dedicated CT imaging, but also to hybrid PET/CT and SPECT/CT, where it could also ensure an accurate CT image for lesion localization and attenuation correction of the functional image data. (paper)

  17. Usefulness of unenhanced helical CT in patients with suspected ureteral colic

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Nam Kung, Sook; Kim, Heung Cheol; Hwang, Woo Chul; Lee, In Sun; Hwang, Im Kyung; Kim, Ho Chul; Bae, Sang Hoon; Lee, Sang Kon; Lee, Seong Ho [College of Medicine, Hallym Univ., Chunchon (Korea, Republic of)

    2002-07-01

    To determine the usefulness of unenhanced helical CT in patients with suspected renal colic. One hundred and fourteen patients with suspected ureteral colic, referred by physicians, underwent unenhanced helical CT. Two radiologists prospectively interpreted the results, determining the presence or absence of ureter stone and other diseases the arise outside the urinary tract. In cases of ureteral stone, we retrospectively sought secondary signs of hydronephrosis, perinephric fat stranding, thickening of renal fascia, renal enlargement, and the tissue rim sign. Among the 114 patients, 57 were confirmed as having ureter stones. Unenhanced helical CT depicted 57 of 58 stones in 57 patients, producing one false-negative and one false-positive result. Overall, the results showed 98% sensitivity, 95% specificity, 98% positive predictive value, 95% negative predictive value, and 97% accuracy. The frequencies of secondary signs were as follows: hydronephrosis, 95%(54/57); perinephric fat stranding, 81% (46/57); thickening of renal fascia, 77% (44/57); renal enlargement , 65%(37/57); and the tissure rim sign 72%(21/29). In 20 patients, the diagnoses were not related to stone disease and included one false-negative diagnosis of pyonephrosis. Unenhanced helical CT provides information which is valuable in the accurate diagnosis of ureteral stone as well as other diseases that arise outside the urinary tract in patients with suspected renal colic.

  18. Helical CT imaging of clinically suspected appendicitis: Correlation of CT and histological findings

    International Nuclear Information System (INIS)

    Wong, S.K.; Chan, L.P.; Yeo, A.

    2002-01-01

    PURPOSE: The diagnosis of appendicitis is traditionally made on the basis of clinical findings supported by laboratory results. The aim of our study was to determine the accuracy and feasibility of using a relatively new technique of computed tomography (CT) using only colonic contrast medium. MATERIALS AND METHODS: A total of 50 patients clinically diagnosed as having appendicitis were prospectively examined before surgery with thin-collimation helical CT from the L3 level to the acetabular roof with only rectally administered colon contrast medium. The hard copy CT images were reviewed jointly by two radiologists and a consensus was reached for each patient. The results were then compared with the surgical and histological findings at appendicectomy. RESULTS: There were 35 true-positives, one false-positive, 12 true-negatives and two false-negatives for CT. This yielded an accuracy of 94%, sensitivity of 95%, specificity of 92%, positive predictive value of 97% and negative predictive value of 86%. The appendix was identified in 45 patients (90%) and obscured by an inflammatory mass in the remaining five. An alternative diagnosis was found in 10 of 12 normal CT examinations (83%). CONCLUSION: Helical CT with rectal contrast medium is a quick, well tolerated and accurate test to diagnose appendicitis. It can offer alternative, possibly non-surgical diagnosis in patients who would otherwise have undergone laparotomy. Wong, S.K. et al. (2002)

  19. Assessment of hepatic arterial variation using multidetector helical CT-angiography

    International Nuclear Information System (INIS)

    Lee, Dong Hoon; Lee, Jun Woo; Jun, Woong Bae; Lee, Suk Hong

    2001-01-01

    To evaluate the anatomy of the hepatic artery and normal variants using oblique thick-slab maximal intensity projection (MIP) 3-D CT angiography and multidetector helical CT technology. In 70 patients, axial three-phase CT together with multidetector helical CT and a nonionic contrast agent was used to evaluate liver disease. During the early arterial phase, the parameters were as follow: slice thickness, 2.5 mm; table speed, 15 mm/rotation, pitch, 6; contrast material, 4 ml/sec; total 120 ml. Using the MIP technique and an Advantage window voxtal 3.03 system (GE), the images obtained were reconstructed as 3D angiograms. In each case, the arterial anatomy and its variants were recorded. A typical anatomy was found in 53 cases (75.7%). Common variants were a left hepatic artery arising from the left gastric artery(8 cases, 11.4 %) and a right hepatic artery arising from the superior mesenteric artery(3 cases, 4.3%). Other variant cases were right hepatic artery arising from the gastroduodenal artery(2 cases, 2.9%), a proper hepatic artery arising from the left gastric artery (1 case, 1.4%), a hepatomesenteric trunk (1 case), a hepatogastric/splenomesenteric trunk(1 case), and a celiomesenteric trunk (1 case). 3-D hepatic angiography using multidetector helical CT technology is non-invasive and as accurate as conventional angiography for the evaluation of hepatic arterial anatomy. It is thus considered that 3-D CT angiography is very helpful for the evaluation of hepatic arterial anatomy prior to liver surgery such as transplantation or the treatment of hepatocellular carinoma

  20. New reconstruction algorithm in helical-volume CT

    International Nuclear Information System (INIS)

    Toki, Y.; Rifu, T.; Aradate, H.; Hirao, Y.; Ohyama, N.

    1990-01-01

    This paper reports on helical scanning that is an application of continuous scanning CT to acquire volume data in a short time for three-dimensional study. In a helical scan, the patient couch sustains movement during continuous-rotation scanning and then the acquired data is processed to synthesize a projection data set of vertical section by interpolation. But the synthesized section is not thin enough; also, the image may have artifacts caused by couch movement. A new reconstruction algorithm that helps resolve such problems has been developed and compared with the ordinary algorithm. The authors constructed a helical scan system based on TCT-900S, which can perform 1-second rotation continuously for 30 seconds. The authors measured section thickness using both algorithms on an AAPM phantom, and we also compared degree of artifacts on clinical data

  1. Acute appendicitis: sensitivity, specificity and diagnostic accuracy of thin-section contrast-enhanced CT findings

    International Nuclear Information System (INIS)

    Lee, Ji Yon; Choi, Dong Il; Park, Hae Won; Lee, Young Rae; Kook, Shin Ho; Kwang, Hyon Joo; Kim, Seung Kwon; Chung, Eun Chul

    2002-01-01

    To assess the sensitivity, specificity, and diagnostic accuracy of individual contrast-enhanced helical CT findings of acute appendicitis. We retrospectively reviewed the appendiceal helical CT scans, obtained after intravenous contrast administration (abdomen; 7-mm collimation, abdominopelvic junction; 5-mm collimation), of 50 patients with surgically proven acute appendicitis and 112 with alternative diagnoses. The following parameters were analysed by three radiologists: enlarged appendix (>6 mm in diameter), appendiceal wall thickening, appendiceal wall enhancement, no identification of the appendix, appendicolith(s), (appendiceal) intraluminal air, abscess, lymphadenopathy, terminal ileal wall thickening, focal cecal apical thickening, focal colonic wall thickening, and segmental colonic wall thickening. The CT findings of acute appendicitis that statistically distinguished it from alternative diagnoses were an enlarged appendix (sensitivity; 92%, specificity; 93%, diagnostic accuracy; 93%), appendiceal wall thickening (for these three parameters: 68%, 96% and 88%, respectively), periappendiceal fat stranding (90%, 79%, 82%), appendiceal wall enhancement (72%, 86%, 82%), appendicolith (16%, 100%, 74%), and focal cecal apical thickening (14%, 100%, 74%) (for each, p<0305). On thin-section contrast-enhanced helical CT, an enlarged appendix and periappendiceal fat stranding were found in 90% or more patients with acute appendicitis. Appendiceal wall thickening and enhancement were alearly demonstrated and significant findings for diagnosis. Less common but specific findings include appendicolith, focal cecal apical thickening and intramural air, can also help us establish a diagnosis of acute appendicitis

  2. Helical CT findings of gastric wall thickening by peptic ulcer : compared with gastric adenocarcinoma with ulcer

    International Nuclear Information System (INIS)

    Jung, Won Jung; Choi, Jong Chul; Seo, Keum Soo; Koo, Bon Sik; Park, Byeong Ho; Kim, Chung Ku; Lee, Ki Nam; Nam, Kyung Jin

    2000-01-01

    To compare on the basis of helical CT findings gastric wall thickening of peptic gastric ulcer with that of gastric adenocarcinoma with ulcer. Thirty-eight patients with pathologically proven gastric lesion (17 cases of peptic ulcer and 21 cases of ulcerative or ulceroinfiltrative gastric cancer (Borrman type II, III) underwent helical CT, and the findings were retrospectively reviewed in terms of maximum abnormal wall thickness, preservation of the inner enhancing layer, the presence three discriminate layers of gastric wall, and enhancement pattern. The enhancement pattern of abnormally thick wall was compared with that of the portal phase of back muscle, and was defined as low, iso, or high. The Chi-square test and Student t test were used for statistical analysis. In cases of peptic ulcer and gastric cancer with ulceration, maximum abnormal wall thickness was 7-30 (mean, 16.1)mm, and 11-33 (mean, 21.8)mm, respectively. The inner enhancing layer was preserved in 15 of 17 patients (88.2%) and one of 21 (4.8%); three discriminate layers of gastric wall were observed in 8 of 17 patients (47.0%), and one of 21 (4.8%). The enhancement pattern was low in 12 of 17 patients (70.5%), and 3 of 21 (14.3%); iso in 4 of 17 (23.5%), and 4 of 21 (19.0%), and high in one of 17 (5.9%), and 14 of 21 (66.7%). All figures refer, respectively, to the two distinct conditions. In terms of preservation of the inner enhancing layer, three discriminate layers of gastric wall, and a low enhancement pattern, there were statistically significant differences between peptic ulcer and gastric adenocarcinoma with ulcer. Where the enhancement was high, however, the statistically significant difference between the two conditions was even greater. There was no statistically significant difference in terms of gastric wall thickness or iso-attenuation of thickened gastric. Helical CT findings of gastric wall thickening, preservation of the inner enhancing layer, and three discriminate layers of

  3. Helical CT findings of gastric wall thickening by peptic ulcer : compared with gastric adenocarcinoma with ulcer

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Won Jung; Choi, Jong Chul; Seo, Keum Soo; Koo, Bon Sik; Park, Byeong Ho; Kim, Chung Ku; Lee, Ki Nam; Nam, Kyung Jin [College of Medicine, Dong A University, Pusan (Korea, Republic of)

    2000-02-01

    To compare on the basis of helical CT findings gastric wall thickening of peptic gastric ulcer with that of gastric adenocarcinoma with ulcer. Thirty-eight patients with pathologically proven gastric lesion (17 cases of peptic ulcer and 21 cases of ulcerative or ulceroinfiltrative gastric cancer (Borrman type II, III)) underwent helical CT, and the findings were retrospectively reviewed in terms of maximum abnormal wall thickness, preservation of the inner enhancing layer, the presence three discriminate layers of gastric wall, and enhancement pattern. The enhancement pattern of abnormally thick wall was compared with that of the portal phase of back muscle, and was defined as low, iso, or high. The Chi-square test and Student t test were used for statistical analysis. In cases of peptic ulcer and gastric cancer with ulceration, maximum abnormal wall thickness was 7-30 (mean, 16.1)mm, and 11-33 (mean, 21.8)mm, respectively. The inner enhancing layer was preserved in 15 of 17 patients (88.2%) and one of 21 (4.8%); three discriminate layers of gastric wall were observed in 8 of 17 patients (47.0%), and one of 21 (4.8%). The enhancement pattern was low in 12 of 17 patients (70.5%), and 3 of 21 (14.3%); iso in 4 of 17 (23.5%), and 4 of 21 (19.0%), and high in one of 17 (5.9%), and 14 of 21 (66.7%). All figures refer, respectively, to the two distinct conditions. In terms of preservation of the inner enhancing layer, three discriminate layers of gastric wall, and a low enhancement pattern, there were statistically significant differences between peptic ulcer and gastric adenocarcinoma with ulcer. Where the enhancement was high, however, the statistically significant difference between the two conditions was even greater. There was no statistically significant difference in terms of gastric wall thickness or iso-attenuation of thickened gastric. Helical CT findings of gastric wall thickening, preservation of the inner enhancing layer, and three discriminate layers of

  4. The evaluation of gallbladder contractibility for volume measurement by helical 3D-CT-cholangiography

    International Nuclear Information System (INIS)

    Hanaguri, Katsuro; Kimura, Hideaki; Kayashima, Yasuyo; Suemoto, Kouichiro; Makihata, Hiroshi; Maruhashi, Akira; Ohya, Toshihide; Ito, Katsuhide; Shen, Yun.

    1997-01-01

    As a new application of helical (spiral) scan, volume measurement has received a significant interest. Although it is important to evaluate gallbladder contractibility to decide on a treatment plan for a gallbladder lesion, qualitative analysis of gallbladder contractibility is very difficult owing to the fact that the volume of gallbladder can not be measured using usual DIC examination (plain X-P and tomography). In this study, the accuracy of volume measurement of helical CT was checked firstly by gallbladder phantom experiments. Then 128 cases of volume measurement of helical 3D CT Cholangiography (DIC-CT) were performed. Under the conditions of optimized scan technique (3 mm TH, 3 mm/s, 1 mm recon interval, Hispeed, GEMS), the difference of contractibility was obtained between clinical cases with and without thick wall. The experiment has shown that helical 3D CT volume measurement is very simple and highly accurate method which is useful for the evaluation of gallbladder contractibility. (author)

  5. Concept and development of measurement method of time sensitivity profile (TSP) in X-ray CT. Comparison of non-helical, single-slice helical, and multi-slice helical scans

    International Nuclear Information System (INIS)

    Tsujioka, Katsumi; Ida, Yoshihiro; Ohtsubo, Hironori; Takahashi, Yasukata; Niwa, Masayoshi

    2000-01-01

    We focused on the time element contained in a single CT image, and devised the concept of a time-sensitivity profile (TSP) describing how the time element is translated into an image. We calculated the data collection time range when the helical pitch is changed in non helical scans, single slice helical scans, and multi slice helical scans. We then calculated the time sensitivity profile (TSP) from the weighting applied when the data collection time range is translated into an image. TSP was also measured for each scanning method using our self-made moving phantom. TSPs obtained from the calculation and the experiments were very close. TSP showed interesting characteristics with each scanning method, especially in the case of multi slice helical scanning, in which TSP became shorter as helical pitch increased. We referred to the TSP's FWHM as the effective scanning time. When we conducted multi slice helical scanning at helical pitch 3, the effective scanning time increased to about 24% longer than that of a non helical scan. When we conducted multi slice helical scanning at helical pitch 5 or 6, the effective scanning time was about half that of a non helical scan. The time sensitivity profile (TSP) is a totally new concept that we consider an important element in discussing the time resolution of a CT scanner. The results of this review will provide significant data in determining the scanning parameters when scanning a moving object. (author)

  6. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  7. Non-contrast thin-section helical CT of urinary tract calculi in children

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Bates, Gregory D.; Bloom, David A.; Goodsitt, Mitchell M.

    2002-01-01

    Background: Non-contrast thin-section helical CT has gained acceptance for the diagnosis of urinary tract calculi in adults, but experience with the technique in children is limited. Purpose: To evaluate the utility of non-contrast thin section helical CT for the diagnosis of urinary tract calculi in children. Materials and methods: Radiology databases at three pediatric institutions were searched to identify all pediatric patients evaluated by ''renal stone'' protocol CT scans (no oral or intravenous contrast, scans covering the entire urinary tract obtained in helical mode with narrow collimation (< 5 mm)). CT scans were reviewed for the primary finding of urinary tract calculi, for secondary signs of acute urinary tract obstruction and for evidence of alternative diagnoses. Medical records were reviewed to determine clinical presentation and to confirm the eventual diagnosis. Results: One hundred thirty-seven scans of 113 children (mean age: 11.2 years) were studied. Thirty-eight of 94 examinations (40%) performed on 82 children for acute pain and/or hematuria showed ureteral calculi. Alternative diagnoses were suggested by CT on 16 scans (17%). Twenty-eight scans were performed on 10 asymptomatic children with known calculus disease confirming renal stone burden on 21 scans (75%) and persistent ureteral calculi on 6 scans (21%). Upper tract calculi were demonstrated on 10 of 15 scans (67%) performed to evaluate for calculi in patients with known non-calculus genitourinary tract abnormalities. Conclusions: Non-contrast thin section helical CT is a useful method to diagnose urinary tract calculi in children. Radiation dose in this retrospective study may exceed the lowest possible radiation dose for diagnostic accuracy. Further research is needed to optimize CT imaging parameters, while maintaining diagnostic accuracy and minimizing radiation dose. (orig.)

  8. Thin section helical CT findings of klastskin tumor and benign stricture: cholangiographic correlation

    International Nuclear Information System (INIS)

    Choi, Guk Myeong; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Kim, Sun Whe; Cho, Yun Ku; Han, Man Chung; Yeon, Kyung Mo

    1997-01-01

    The purpose of this study was 1) to describe the thin section helical CT findings of hilar cholangiocarcinoma and of benign strcture, and to discuss the differential points between the two disease entities and 2) using cholangiographic correlation, to evaluate the diagnostic accuracy of helical CT in determining the extent of hilar cholangiocarcinoma. Twenty-seven patients with hilar cholangiocarcinoma and eight with benign biliary dilatation were studied. All except four with hilar cholangiocarcinoma, who underwentCT using a conventional scanner, were studied with two-phase helical CT. In all patients, cholangiographs were obtained by digital fluoroscopy after the injection of contrast materials into PTBD catheters. The level of obstruction was classified according to Bismuth, and 35 CT scans were studied blindly and retrospectively by two radiologists. The findings were analyzed for the presence of tumor, and then divided into two groups(cholangiocarcinomas and benign strictures), and the positive predictive value was calculated. The CT images of klatskin tumor were analyzed with special emphasis on the level and shape of the hilar obstruction. The level of biliary obstruction and extent of the tumor were carefully correlated with the results of cholangiography. Thin-section spiral CT correctly identified all tumor mass as a focal wall thickening obliterating the lumen. On arterial/portal phase CT scanning, 81% of infilterative tumors showed high attenuation. In all patients, differentiation between benign stricture and klaskin tumor was possible;correct identification of the level of obstruction and extent of tumor, according to Bismuth's classification, was possible in 63% of cases. For correct diagnosis of hilar cholangiocarcinoma and differentiation of benign stricture, helical CT was highly accurate and effective. Because of limital Z-axis resolution, however, the exact intraductal extent of the tumor was less accorately diagnosed.=20

  9. Helical CT for secondary screening of lung cancer

    International Nuclear Information System (INIS)

    Mori, Kiyoshi; Onishi, Tsukasa; Tominaga, Keigo; Kishiro, Izumi; Yokoyama, Kohki.

    1995-01-01

    Helical CT was used on a trial basis for secondary screening of lung cancer, and its clinical usefulness is discussed in this report. The subjects of 157 patients with abnormal shadows on plain chest X-ray images were chosen between November 1993 and August 1994. Imaging parameters used for screening CT were as follows: 50 mA, 120 kV, a couch-top movement speed of 20 mm/s, and a beam width of 10 mm. The entire lung field was scanned during a single breath-hold. Reconstructed images were generated at 10-mm intervals by the 180deg interpolation method, and films were produced. Images of the entire lung field were made during a single breath-hold in all patients. Abnormal shadows were detected in 73 of 157 patients by screening CT. These 73 patients included 14 with lung cancer, 53 with benign lesions, one under observation, and five others. The average diameter of the tumors was 11.1 mm. The lung cancers detected all arose in the periphery, and were classified into stage I (10 patients), stage IIIA (3 patients), and stage IV with bone metastases (1 patient). Lung cancers in clinical stage I (3 patients) and stage IV (1 patient) were difficult to see on plain chest X-ray films. We conclude that screening CT is useful for early diagnosis of lung cancer because the entire lung field can be imaged during a single breath-hold. Therefore, helical CT can be expected to be useful in screening for lung cancer. (author)

  10. Low-dosage helical CT applications for chest medical checkup and lung cancer screening

    International Nuclear Information System (INIS)

    Wang Ping; Cui Fa; Liang Huanqing; Zheng Minfei

    2005-01-01

    Objective: A discussion on low-dosage helical CT applications on chest medical checkup and lung cancer screening. Methods: On the 100 chest medical check up with three different of protocols, including standard-dosage (the tube current was 230 mAs) were compared with low-dose (tube current was 50 mAs or 30 mAs). Results: Low-dosage helical CT scan provides excellent images. In 100 chest medical checkup, 39 nodules or masses were revealed, enlarged lymph node was noted in 1 case; emphysema or bullae was demonstrated in 3 segments; thickening of bronchial wall was shown in 2 cases; and localized pleural thickening was found in 1 case. Conclusion: In chest checkup or lung cancer screening low-dosage helical CT (tube current 30 mAs) will not only guarantee image quality but also reduce the radiation dose during the examination. (authors)

  11. The usefulness of three-dimensional helical CT for the detection of abnormalities of the auditory ossicles

    International Nuclear Information System (INIS)

    Gong, Honghan; Hiraishi, Kumiko; Uesugi, Yasuo; Shimizu, Tadafumi; Narabayashi, Isamu

    1996-01-01

    To evaluate the usefulness of three-dimensional (3D) helical CT for the detection of abnormalities of the auditory ossicles, 3D helical CT of the middle ear was performed in seven patients with hearing disorder. It revealed that 4 patients had congenital deficiency of the auditory ossicles, 2 patients with chronic otitis media had shortening of the incus and one patient with head injury had doubtful fracture of the incus. This study indicated that 3D helical CT of the middle ear can represent the auditory ossicles objectively and can offer detailed diagnosis. (author)

  12. An experimental study for qualitatively diagnosing stapes lesions by helical 3-dimensional CT

    International Nuclear Information System (INIS)

    Kawaue, Akifumi; Kuki, Kiyonori; Yamanaka, Noboru; Nishimura, Michihiko

    2001-01-01

    To evaluate qualitative diagnosis of stapes lesions by 3-dimensional computed tomography (3D-CT) combined with superselective image processing (3D-SS) of stapes, we studied helical 3D-CT on a phantom model of the temporal bone. Two stapes models were used-1 made from the bone filler, Celatite, consistent in bone density but changing in cross sectional area, and the other made from an apacerum rod used in quantitative computed tomography (QCT), consistent in cross sectional area but changing in bone density. These stapes models were put into a skull phantom and analyzed by helical 3D-CT. The influence of the tympanic cavity conditions on CT images of stapes was evaluated by filling the phantom model with Vaseline following 3D selective reconstruction. In all stapes models, lowering the lower CT window width threshold resulted in an enlarged cross-sectional area of the model. The higher the bone density, the lower the increase in cross-sectional area in the image. The stapes model with lower density had greater influence on the imaging by tympanic cavity conditions and was likely to be misdiagnosed as showing higher bone density. Based on the experimental study, 3D-SS by helical 3D-CT appears to be a useful measure for qualitatively diagnosing stapes lesions. (author)

  13. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  14. Multidetector helical CT plus superparamagnetic iron oxide-enhanced MR imaging for focal hepatic lesions in cirrhotic liver: A comparison with multi-phase CT during hepatic arteriography

    International Nuclear Information System (INIS)

    Yukisawa, Seigo; Okugawa, Hidehiro; Masuya, Yoshio; Okabe, Shinichirou; Fukuda, Hiroyuki; Yoshikawa, Masaharu; Ebara, Masaaki; Saisho, Hiromitsu

    2007-01-01

    The aim of this study was to evaluate multidetector helical computed tomography (MDCT), superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging, and CT arterial portography (CTAP) and CT during hepatic arteriography (CTHA) for the detection and diagnosis of hepatocellular carcinomas (HCC). This included visual correlations of MDCT and SPIO-MR imaging in the detection of HCC using receiver operating characteristic (ROC) analysis. Twenty-five patients with 57 nodular HCCs were retrospectively analyzed. A total of 200 segments, including 49 segments with 57 HCCs, were reviewed independently by three observers. Each observer read four sets of images (set 1, MDCT; set 2, unenhanced and SPIO-enhanced MR images; set 3, combined MDCT and SPIO-enhanced MR images; set 4, combined CTAP and CTHA). The mean Az values representing the diagnostic accuracy for HCCs of sets 1, 2, 3, and 4 were 0.777, 0.814, 0.849, and 0.911, respectively, and there was no significant difference between sets 3 and 4. The sensitivity of set 4 was significantly higher than those of set 3 for all the lesions and for lesions 10 mm or smaller (p < 0.05); however, for lesions larger than 10 mm, the sensitivities of the two sets were similar. No significant difference in positive predictive value and specificity was observed between set 3 and set 4. Combined MDCT and SPIO-enhanced MR imaging may obviate the need for more invasive CTAP and CTHA for the pre-therapeutic evaluation of patients with HCC more than 10 mm

  15. Image quality of high-resolution CT with 16-channel multidetector-row CT. Comparison between helical scan and conventional step-shoot scan

    International Nuclear Information System (INIS)

    Sumikawa, Hiromitsu; Johkoh, Takeshi; Koyama, Mitsuhiro

    2005-01-01

    The aim of this study was to evaluate the image quality of high-resolution CT (HRCT) reconstructed from volumetric data with 16-channel multidetector-row CT (MDCT). Eleven autopsy lungs that were diagnosed histopathologically were scanned by 16-channel MDCT with the step-and-shoot scan mode and three helical scan modes. Each helical mode had each size of focal spot, pitch, and time of gantry rotation. HRCT images were reconstructed from the volumetric data with each helical mode and axial sequence data. Two observers evaluated the image quality and noted the most appropriate diagnosis for each imaging. Visualization of abnormal structures with one helical mode was equal to those with axial mode, whereas those with the other two helical modes were inferior to those with axial mode (Wilcoxon signed rank test; p<0.0001). There was no significant difference in diagnostic efficacy between modes. The image quality of HRCT with appropriate helical mode is equal to that with axial mode and diagnostic efficacy is equal among all modes. These results may indicate that sufficient HRCT images can be obtained by only one helical scan without the addition of conventional axial scans. (author)

  16. Helical CT defecography; La defecografia con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M. [Genua Univ., Genua (Italy). Ist. di Radiologia, Cattedra R; Tornago, S. [Genua Univ. Genua (Italy). 2 Clinica Ortopedica

    1999-11-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases. [Italian] Scopo di questo lavoro e' ricercare un ruolo per la defeco-TC con apparecchiatura elicoidale nello studio delle malattie del pavimento pelvico confrontandola con i risultati consolidati della defecografia tradizionale. Si sono visionati 90 pazienti, 62 femmine e 28 maschi, con eta' compresa tra 24 e 82 anni, con defecografia tradizionale; di questi, 18 casi con diagnosi dubbia sono stati studiati anche con defeco-TC spirale

  17. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  18. An evaluation of the regional cerebral blood flow (rCBF) measurement by xenon-enhanced dynamic CT with helical scanning technique and the functional imaging by multiplanar reconstruction (MPR). Fundamental study and clinical application

    International Nuclear Information System (INIS)

    Watanabe, Kenichi

    1997-01-01

    We evaluated the quantitative rCBF by xenon-enhanced dynamic CT with helical scanning technique on all brain regions, and also examined clinical usefulness of coronal and sagittal section images which are similar to SPECT images obtained by the functional multiplanar reconstitution (MPR) imaging of many successive flow maps. We used 14 clinical cases. The conventional xenon-enhanced CT was simple and ideal method to measure rCBF, however, it had disadvantages; it gives a few laminagraphical images or only the axial directional images, compared to SPECT or PET. There is a risk to overlook lesions out of the image or not to obtain the whole images of the lesion. Although the helical scanning technique has a methodological characteristics to use adjacent data for the image reconstitution, it is by no means inferior to the conventional method in the contrast resolution or the image resolution when the co-helical function and an appropriate reconstituted function were used. It has an advantage to scan all brain regions by only one cycle of scanning. Furthermore on making good use of the property that the helical scanning technique can give the successive data, we can observe rCBF by coronal and sagittal images when many flow maps were made up by reconstituted images of the narrow steps. This shows the clinical usefulness of this technique. One of the future problem to be solved is to decrease the exposure dose. (K.H.)

  19. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  20. Maximum-intensity-projection CT angiography for evaluating head and neck tumors. Usefulness of helical CT and auto bone masking method

    International Nuclear Information System (INIS)

    Sakai, Osamu; Nakashima, Noriko; Ogawa, Chiaki; Shen, Yun; Takata, Yasunori; Azemoto, Shougo.

    1994-01-01

    Angiographic images of 10 adult patients with head and neck tumors were obtained by helical computed tomography (CT) using maximum intensity projection (MIP). In all cases, the vasculature of the head and neck region was directly demonstrated. In the head and neck, bone masking is a more important problem than in other regions. We developed an effective automatic bone masking method (ABM) using 2D/3D connectivity. Helical CT angiography with MIP and ABM provided accurate anatomic depiction, and was considered to be helpful in preoperative evaluation of head and neck tumors. (author)

  1. Measurement of MV CT dose index for Hi-ART helical tomotherapy unit

    International Nuclear Information System (INIS)

    Wang Yunlai; Liao Xiongfei

    2010-01-01

    Objective: To evaluate the patient dose from Hi-ART MV helical CT imaging in image-guided radiotherapy. Methods: Weighted CT dose index (CTDI W ) was measured with PTW TM30009 CT ion chamber in head and body phantoms, respectively,for slice thicknesses of 2, 4, 6 mm with scanned range of 5 cm and 15 cm. Dose length products (DLP) were subsequently calculated. The CTDI W and DLP were compared with XVI kV CBCT and ACQSim simulator CT for routine clinical protocols. Results: An inverse relationship between CTDI and the slice thickness was found. The dose distribution was inhomogeneous owing to the attenuation of the couch. CTDI and DLP had close relationship with the slice thickness and the scanned range. Patient dose from MVCT was lower than XVI CBCT for head, but larger for body scan. Conclusions: CTDI W can be used to assess the patient dose in MV helical CT due to its simplicity for measurement and reproducibility. Regular measurement should be performed in QA and QC program. Appropriate slice thickness and scan range should be chosen to reduce the patient dose. (authors)

  2. Hepatic and vascular enhancement at dual-phase helical CT: comparison of Iobitridol 300 and Iohexol 300 in a prospective randomized study

    International Nuclear Information System (INIS)

    Legmann, P.; Vignaux, O.; Bahurel, H.; Oudjit, A.; Coste, J.

    2001-01-01

    The purpose of this study was to determine hepatic and vascular enhancement, clinical tolerance, and iconographic quality of Iobitridol (300 mg/ml) at dual-phase helical CT and to compare it with Iohexol (300 mg/ml). One hundred forty-six patients were randomly divided into two groups. Each group received 120 ml of Iohexol (group A) or Iobitridol (group B). Mean enhancement of liver, aorta and portal vein was obtained at the arterial phase and at the portal-venous phase. Overall image quality was assessed by two independent blinded investigators. Adverse reactions were recorded. There were no significant differences in demographic characteristics and distribution of patient intrinsic parameters between the two groups, except for blood pressure but without statistical correlation between the difference in blood pressure and the impact on enhancement measurements. There was no significant difference in clinical tolerance and image quality. Mean liver as well as aortic and portal vein enhancement measurements did not show any significant difference. Iobitridol compares favorably with Iohexol. Both products have similar safety, tolerance, and efficacy. Both contrast media have equivalent blood pool concentration and interstitial compartment diffusion. (orig.)

  3. Hepatic and vascular enhancement at dual-phase helical CT: comparison of Iobitridol 300 and Iohexol 300 in a prospective randomized study

    Energy Technology Data Exchange (ETDEWEB)

    Legmann, P.; Vignaux, O.; Bahurel, H.; Oudjit, A. [Dept. of Radiology, Universite Rene Descartes, Paris (France); Coste, J. [Dept. of Biostatistics and Epidemiology, Universite Rene Descartes, Paris (France)

    2001-11-01

    The purpose of this study was to determine hepatic and vascular enhancement, clinical tolerance, and iconographic quality of Iobitridol (300 mg/ml) at dual-phase helical CT and to compare it with Iohexol (300 mg/ml). One hundred forty-six patients were randomly divided into two groups. Each group received 120 ml of Iohexol (group A) or Iobitridol (group B). Mean enhancement of liver, aorta and portal vein was obtained at the arterial phase and at the portal-venous phase. Overall image quality was assessed by two independent blinded investigators. Adverse reactions were recorded. There were no significant differences in demographic characteristics and distribution of patient intrinsic parameters between the two groups, except for blood pressure but without statistical correlation between the difference in blood pressure and the impact on enhancement measurements. There was no significant difference in clinical tolerance and image quality. Mean liver as well as aortic and portal vein enhancement measurements did not show any significant difference. Iobitridol compares favorably with Iohexol. Both products have similar safety, tolerance, and efficacy. Both contrast media have equivalent blood pool concentration and interstitial compartment diffusion. (orig.)

  4. Evaluation of coronary artery disease by helical CT using retrospective ECG-gating

    International Nuclear Information System (INIS)

    Kawawa, Yoko

    2001-01-01

    The purpose of this study is to evaluate the usefulness of helical CT using retrospective ECG-gating for visualization of the coronary artery and detection of coronary artery disease. We performed a coronary artery phantom study and established this new application, with 1-mm collimation, 1-mm table increment, and 0.1-mm reconstruction (0.8 sec/rotation). Helical CT of 31 patients with 39 coronary artery diseases (34 coronary artery stenoses, 1 vasospastic angina, 1 coronary artery dissection, 1 coronary artery ectasia and 2 coronary artery aneurysms) was performed in a single breath hold and ECG-gating without and with intravenous injection of nonionic iodine contrast material. We selected the images which were not affected by cardiac motion from the reconstruction images, in order to visualize the coronary artery for detection of coronary artery disease. The coronary artery was well visualized in 32 out of 39 vessels (82%). A good visualization of the coronary artery was correlated with the heart rate. Further, in this well visualized group, coronary artery diseases were detected in 24 out of 31 cases (77%). One case of vasospastic angina was not included. It was difficult to detect coronary artery disease in cases of heavily calcified vessels or in the left circumflex artery. Helical CT using this retrospective ECG-gating is a useful noninvasive examination for evaluation of coronary artery disease. (author)

  5. Clinical application of helical CT 3D reconstruction for the dental orthopaedics

    International Nuclear Information System (INIS)

    Han Benyi; Jiang Xiaolu; Li Hongru

    2005-01-01

    Objective: To evaluate the clinical application of helical CT 3D reconstruction technique in the dental orthopaedics. Methods: The helical CT was performed with 3.0 mm slice thickness and 1.0 pitch in 41 patients with dental orthopaedics. The 3D reconstructions, including maximum intensity projection (MIP), surface shaded display (SSD), and multiplanar reconstructions (MPR), were made for all the cases. Results: Thirty-seven of the 41 patients showed malalignment, tilt, rotation, overlap of the teeth and the different space between the longitudinal axes of the teeth. Twenty-five cases of them have shown 36 buried teeth in all. The axial images covered all the information. SSD demonstrated the external contours and entire morphologies of the teeth and the mandible with the relationship of the teeth alignment and the mandible. MIP clearly manifested the full view and the longitudinal alignment of the teeth. Among the 36 buried teeth, there were 29 palatally and 7 labially presented teeth, and they were morphologically delineated on MIP through various angles. Conclusion: The helical CT 3D reconstruction is a new technique to display the stereoscopic configuration of teeth. The combination of axial images and MIP, SSD, and MPR provides valuable anatomic and diagnostic information helpful for the surgeons to structure and determine the treatment protocol for the dental orthopaedics. (authors)

  6. Unenhanced helical CT in the investigation of acute flank pain

    International Nuclear Information System (INIS)

    Colistro, Robert; Torreggiani, William C.; Lyburn, Iain D.; Harris, Alison C.; Al-Nakshabandi, Nizar A.; Nicolaou, Savvas; Munk, Peter L.

    2002-01-01

    Unenhanced helical CT has emerged as the imaging technique of choice for the investigation of patients presenting with acute flank pain and suspected nephroureteric stone disease. There are several signs identifiable on unenhanced CT that support a diagnosis of stone disease. However, there are many pitfalls, that may confound a correct diagnosis. Some of the common pitfalls, together with methods to avoid such occurrences, will be discussed. A review of some of the common alternative diagnoses that may mimic the symptoms of nephroureteric stone disease is illustrated. Colistro, R. et al (2002)

  7. Preliminary study on helical CT algorithms for patient motion estimation and compensation

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    1995-01-01

    Helical computed tomography (helical/spiral CT) has replaced conventional CT in many clinical applications. In current helical CT, a patient is assumed to be rigid and motionless during scanning and planar projection sets are produced from raw data via longitudinal interpolation. However, rigid patient motion is a problem in some cases (such as in the skull base and temporal bone imaging). Motion artifacts thus generated in reconstructed images can prevent accurate diagnosis. Modeling a uniform translational movement, the authors address how patient motion is ascertained and how it may be compensated. First, mismatch between adjacent fan-beam projections of the same orientation is determined via classical correlation, which is approximately proportional to the patient displacement projected onto an axis orthogonal to the central ray of the involved fan-beam. Then, the patient motion vector (the patient displacement per gantry rotation) is estimated from its projections using a least-square-root method. To suppress motion artifacts, adaptive interpolation algorithms are developed that synthesize full-scan and half-scan planar projection data sets, respectively. In the adaptive scheme, the interpolation is performed along inclined paths dependent upon the patient motion vector. The simulation results show that the patient motion vector can be accurately and reliably estimated using their correlation and least-square-root algorithm, patient motion artifacts can be effectively suppressed via adaptive interpolation, and adaptive half-scan interpolation is advantageous compared with its full-scale counterpart in terms of high contrast image resolution

  8. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning

    International Nuclear Information System (INIS)

    Tang Xiangyang; Hsieh Jiang; Nilsen, Roy A; Dutta, Sandeep; Samsonov, Dmitry; Hagiwara, Akira

    2006-01-01

    Based on the structure of the original helical FDK algorithm, a three-dimensional (3D)-weighted cone beam filtered backprojection (CB-FBP) algorithm is proposed for image reconstruction in volumetric CT under helical source trajectory. In addition to its dependence on view and fan angles, the 3D weighting utilizes the cone angle dependency of a ray to improve reconstruction accuracy. The 3D weighting is ray-dependent and the underlying mechanism is to give a favourable weight to the ray with the smaller cone angle out of a pair of conjugate rays but an unfavourable weight to the ray with the larger cone angle out of the conjugate ray pair. The proposed 3D-weighted helical CB-FBP reconstruction algorithm is implemented in the cone-parallel geometry that can improve noise uniformity and image generation speed significantly. Under the cone-parallel geometry, the filtering is naturally carried out along the tangential direction of the helical source trajectory. By exploring the 3D weighting's dependence on cone angle, the proposed helical 3D-weighted CB-FBP reconstruction algorithm can provide significantly improved reconstruction accuracy at moderate cone angle and high helical pitches. The 3D-weighted CB-FBP algorithm is experimentally evaluated by computer-simulated phantoms and phantoms scanned by a diagnostic volumetric CT system with a detector dimension of 64 x 0.625 mm over various helical pitches. The computer simulation study shows that the 3D weighting enables the proposed algorithm to reach reconstruction accuracy comparable to that of exact CB reconstruction algorithms, such as the Katsevich algorithm, under a moderate cone angle (4 deg.) and various helical pitches. Meanwhile, the experimental evaluation using the phantoms scanned by a volumetric CT system shows that the spatial resolution along the z-direction and noise characteristics of the proposed 3D-weighted helical CB-FBP reconstruction algorithm are maintained very well in comparison to the FDK

  9. Cost-effectiveness analysis on the results of screening of lung cancer using helical CT conducted by the anti-lung cancer association (ALCA)

    International Nuclear Information System (INIS)

    Iinuma, Takeshi; Kaneko, Masahiro; Moriyama, Noriyuki; Misawa, Jun

    1999-01-01

    To compare Yen/person saved in lung cancer screening using helical CT with Yen/person in the screening using conventional direct chest X-rays conducted under the Anti-lung cancer association program of the Tokyo Health Service Association. A mathematical model for cancer screening was used to estimate net number of person relieved from lung cancer by the screening and net cost required for the screening. Finally cost-effectiveness ratios in terms of Yen/person saved were calculated and compared between the two programs. Several important variables employed in the model were as follows: 5 year survival rate in chest X-ray group was 50%, and the rate in helical CT group was 75%. Cost of screening in the chest X-ray group was 15,000 Yen, and that in the helical CT group was 25,000 Yen. Cost/person screened was 14,470 Yen for chest X-ray and 21,890 Yen for helical CT. Cost/person saved was 267 x 10 5 Yen in X-ray group and 112 x 10 5 Yen in CT group. Thus the cost was higher, but cost-effectiveness ratio was better in the CT screening group. Helical CT can be adopted for lung cancer screening in stead of chest X-ray if total cost is affordable. (author)

  10. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki

    1996-01-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  11. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki [Fukushima Medical School (Japan)

    1996-05-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  12. Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China); Wang, Yining; Jin, Zhengyu [Chinese Academy of Medical Sciences, Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Zhang, Longjiang; Lu, Guangming [Nanjing University, Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing, Jiangsu (China)

    2013-07-15

    To investigate the feasibility of applying prospectively ECG-triggered sequential coronary CT angiography (CCTA) to patients with atrial fibrillation (AF) and evaluate the image quality and radiation dose compared with a retrospectively ECG-gated helical protocol. 100 patients with persistent AF were enrolled. Fifty patients were randomly assigned to a prospective protocol and the other patients to a retrospective protocol using a second-generation dual-source CT (DS-CT). Image quality was evaluated using a four-point grading scale (1 = excellent, 2 = good, 3 = moderate, 4 = poor) by two reviewers on a per-segment basis. The coronary artery segments were considered non-diagnostic with a quality score of 4. The radiation dose was evaluated. Diagnostic segment rate in the prospective group was 99.4 % (642/646 segments), while that in the retrospective group was 96.5 % (604/626 segments) (P < 0.001). Effective dose was 4.29 {+-} 1.86 and 11.95 {+-} 5.34 mSv for each of the two protocols (P < 0.001), which was a 64 % reduction in the radiation dose for prospective sequential imaging compared with retrospective helical imaging. In AF patients, prospectively ECG-triggered sequential CCTA is feasible using second-generation DS-CT and can decrease >60 % radiation exposure compared with retrospectively ECG-gated helical imaging while improving diagnostic image quality. (orig.)

  13. Acute ureterolithiasis: Incidence of secondary signs on unenhanced helical CT and influence on patient management

    Energy Technology Data Exchange (ETDEWEB)

    Ege, G. E-mail: gurkanege@yahoo.com; Akman, H.; Kuzucu, K.; Yildiz, S

    2003-12-01

    AIM: The purpose of this study was to determine the incidence of secondary signs associated with ureteral stones on unenhanced helical computed tomography (CT) of patients with acute renal colic, and to correlate these with patient management and outcome. MATERIALS AND METHODS: One hundred and ten patients with ureterolithiasis were evaluated prospectively for the secondary signs of obstruction on unenhanced helical CT. Our attention was focused primarily on the presence or absence of seven secondary signs on unenhanced helical CT, including hydronephrosis, unilateral renal enlargement, perinephric oedema, unilateral absence of the white pyramid, hydroureter, periureteral oedema and lateroconal fascial thickening. RESULTS: Of the 110 patients, 91 (82.7%) had hydroureter, 88 (80%) had hydronephrosis, 65 (59%) had periureteric oedema and 63 (57.2%) had unilateral renal enlargement. Ninety stones passed spontaneously and 21 required intervention. CONCLUSION: Secondary signs of urinary tract obstruction are useful and supportive findings in interpretation of the CT examination. In our experience, the most reliable signs indicating ureteral obstruction are hydroureter, hydronephrosis, periureteral oedema and unilateral renal enlargement, respectively. In addition, stones larger than 6 mm, located within the proximal two thirds of the ureter, and seen associated with five or more the secondary signs of obstruction, are more likely to require endoscopic removal and/or lithotripsy.

  14. Bronchial carcinoid tumor: helical CT and virtual bronchoscopy

    International Nuclear Information System (INIS)

    Diez, Eduardo; Carrascosa, Patricia; Capunay, Carlos; Spinozzi, German; Abramson, Horacio; Berna, Miguel

    2001-01-01

    The authors reported a case of a 61 years old man with recurrent neumonia of the inferior right lobe diagnosed by a chest radiography. A complementary helical CT showed an endobronquial mass on the right intermediate bronchus. Virtual bronchoscopy contributed to a better definition of this lesion, confirmed by a real bronchoscopy. The lesion was diagnosed as a carcinoid tumor by a bronchial biopsy. After surgery (sleeve resection of the tumor) the patient did not show any recurrence of his broncho-neumonic clinical features. (author)

  15. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  16. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT; Fruehes klinisches Management nach Polytrauma mit 1- und 4-Schicht-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Kloeppel, R.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Schreiter, D. [Chirurgische Intensivtherapieabteilung, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany); Dietrich, J. [Abt. Neuroradiologie der Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Josten, C. [Klinik und Poliklinik fuer Unfall- und Wiederherstellungschirurgie, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany)

    2002-07-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of {approx}30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by {approx}4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [German] Die klinische Erstversorgung Polytraumatisierter schliesst inzwischen in vielen Unfallkliniken den fruehzeitigen Einsatz der Spiral-CT ein. Kann die neuerlich eingefuehrte Mehrschicht-Spiral-CT Ergebnisse und Patientenmanagement weiter verbessern?Nach lebensrettenden Sofortmassnahmen, Thoraxroentgen und Notsonographie im Schockraum erfolgte die CT: Von 1998-2000 wurden 241 Patienten mit einem 1-Schicht-Spiral-CT (Somatom plus 4) und in 2001 79 Patienten mit einem 4-Schicht-Spiral-CT (Somatom VZ, beide Siemens Med. Sol.) untersucht. Klinisch ausgewaehlte Extremitaetenaufnahmen wurden ergaenzt.359 von 360 Untersuchungen verliefen erfolgreich

  17. Current status of multi-detector row helical CT in imaging of adult ...

    African Journals Online (AJOL)

    Current status of multi-detector row helical CT in imaging of adult acquired pancreatic diseases and assessing surgical neoplastic resectability. ... The presence of inflammation, masses, and vascular invasion was evaluated and interpreted images were obtained during each phase. Results were compared with surgery, ...

  18. New approach to lung cancer screening with helical volume CT

    International Nuclear Information System (INIS)

    Midorikawa, S.; Hashimoto, N.; Katakura, T.; Suzuki, K.

    1990-01-01

    This paper evaluates the relationship between reducing radiation dose to the patient and maintaining the clinical quality of the chest image in lung cancer screening by helical-volume CT (HVCT). The authors evaluated the changing relationship between radiation dose and clinical quality after changing the HVCY scanning conditions (such as stroke of patient transport and section thickness) as well as adding copper filters of various thickness and using high-voltage x-ray examination to complement CT examinations. The authors were able to reduce radiation dose by changing the HVCT scanning conditions (eg, stroke of 20 mm/sec, with a section thickness of 10 mm)

  19. Multi-detector row helical CT of the liver. Quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT. A prospective randomized study

    International Nuclear Information System (INIS)

    Tsurusaki, Masakatsu; Sugimoto, Koji; Fujii, Masahiko; Sugimura, Kazuro

    2004-01-01

    The purpose of this study was to assess the quantitative effects of contrast material concentration on hepatic parenchymal and vascular enhancement in multiphasic computed tomography (CT), using multi-detector row helical CT. We designed a prospective randomized study to test two different concentrations of contrast material on five phasic scans of the liver. One hundred patients were randomly assigned to two groups: an iodine concentration of 300 mg/mL in group A and 370 mg/mL in group B. All patients received a fixed volume of 100 mL at a 4 mL/sec injection rate. Enhancement values for the hepatic parenchyma and aorta at three levels (upper, middle, and lower level of the liver), and values for portal and hepatic veins were statistically compared between the two groups. Hepatic parenchymal enhancement values at all levels of the liver in portal phase (PP) and equilibrium phase (EP) were significantly higher in group B than in group A (p<0.01). Aortic enhancement values at two levels of the liver (middle and lower) in early hepatic arterial phase (EAP) were significantly higher in group B than in group A (p<0.05), however, there was no significant difference between groups A and B in aortic enhancement during the delayed hepatic arterial phase (DAP). Portal and hepatic venous enhancement values in PP and EP were significantly higher in group B than in group A (p<0.01). On multiphasic dynamic CT, the use of a higher iodine concentration of contrast material results in higher hepatic parenchymal enhancement and aortic enhancement, as well as higher portal and hepatic venous enhancement. (author)

  20. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  1. Impact of polychromatic x-ray sources on helical, cone-beam computed tomography and dual-energy methods

    International Nuclear Information System (INIS)

    Sidky, Emil Y; Zou Yu; Pan Xiaochuan

    2004-01-01

    Recently, there has been much work devoted to developing accurate and efficient algorithms for image reconstruction in helical, cone-beam computed tomography (CT). Little attention, however, has been directed to the effect of physical factors on helical, cone-beam CT image reconstruction. This work investigates the effect of polychromatic x-rays on image reconstruction in helical, cone-beam computed tomography. A pre-reconstruction dual-energy technique is developed to reduce beam-hardening artefacts and enhance contrast in soft tissue

  2. The effect of pitch in multislice spiral/helical CT

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    2000-01-01

    The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per x-ray source rotation. The pitch in multislice spiral CT is defined as the ratio of the table increment over the detector collimation in this study. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is nonuniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensibility of signal reconstruction from non-uniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multislice spiral CT. Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensibility of raw data interpolation in multislice spiral CT increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-slice spiral CT is provided. The study on the effect of pitch using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multislice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multislice spiral CT scanners and imaging protocol optimization in clinical applications. (authors)

  3. Spatial variation of the section sensitivity profile in helical CT

    International Nuclear Information System (INIS)

    Katsuta, Shoichi; Hanai, Kouzou; Kunii, Takeo; Kimura, Haruki; Imabayashi, Wataru; Muramatsu, Yoshihisa

    1999-01-01

    The section sensitivity profile (SSP) is adequate to express the properties of helical CT images. Although SSP measurement has been performed only at the center of the imaging field, we applied it to off-center positions using a metal bead and controlled tracking technique. The experimental results indicated that SSP curves vary in the imaging field according to the relative position of the x-ray focus. The results were in agreement with computer simulations. (author)

  4. Emergencies in the retroperitoneum: assessment of spread of disease by helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Scialpi, M. E-mail: michelescialpi@libero.it; Scaglione, M.; Angelelli, G.; Lupattelli, L.; Resta, M.C.; Resta, M.; Rotondo, A

    2004-04-01

    Acute pancreatitis, leaking abdominal aortic aneurysm, and renal trauma frequently occur in the setting of patients with abdominal nontraumatic and traumatic injury; it represents the most urgent conditions that may determine the presence of fluid collections or haematoma in the retroperitoneum. Single spiral CT and multidetector-row CT (MDCT) play an important role in diagnosis of retroperitoneal emergencies, providing useful informations on the type, site, extent and management of the fluid collections. An accurate CT assessment requires the awareness of the existence of dissectable retroperitoneal fascial planes. Fluid collections or haematoma tends to escape the retroperitoneal site of origin into planes extend from the diaphragm to the pelvic floor. We assess the multicompartimental anatomy of the retroperitoneum and the pathway of spread of the most frequent retroperitoneal fluid collections or haematoma by helical CT.

  5. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  6. Patellofemoral joint dysfunction. Combined diagnostic imaging evaluation (X-rays, 3D helical CT and MRI)

    International Nuclear Information System (INIS)

    Carrascosa, P.; Sanchez, F.; Mazzucco, J.; Capanay, C.; Carrascosa, J.

    2000-01-01

    The comprehensive study including 3D helical CT, Magnetic Resonance (MR) and X-ray exams provide a more complete diagnosis than those obtained through the conventional CT. We studied 43 patients with presumptive or certain diagnosis of patellofemoral instability. All the patients were studied by: a) Radiological pair; b) Tomography under extension and flexion, without and with contraction, using a helical CT equipment; and c) MRI STIR sequence in axial plane. The findings were classified as muscular lesion, cartilage lesion, bone and associated lesions (e.g. synovitis), statistically comparing both studies (comprehensive vs. conventional). The results allow us to accept the hypothesis that the comprehensive study provides a more complete diagnosis about the origin of the patellofemoral dysfunction. In 65% of the patients, the conventional study gave a negative result. Only in 35% of the cases the result was positive, but incomplete, showing only 35.3% of the pathological findings detected by the comprehensive study. (author)

  7. Technical evaluation of DIC helical CT and 3D image for laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Shibuya, Kouki; Uchimura, Fumiaki; Haga, Tomo

    1995-01-01

    Recently Laparoscopic Cholecystectomy (L.C.) was widely accepted for its low invasive procedure. Before L.C., it is important to understand anatomical recognization of biliary tree. We examined DIC Helical CT before L.C., and reconstructed 3D Cholangiographic image. We evaluated physical potentiality of Helical CT using Section Sensitivity Profiles (SSP) with 5, 10 mm slice thickness on 360deg linear interpolation. And we analyzed most useful 3D image for biliary tree. Results showed the SSP depended on slice thickness (X-ray beam width) and table movement at same reconstruction spacing. The peak of SSP depended on slice thickness (X-ray beam width) and reconstruction spacing at same table movement. Clinically, it was necessary under 5 mm/rotation table movement and 5 mm thickness for acquiring volume image data. 3D Cholangiographic image reconstructed with 1 mm spacing image was useful in evaluation of relationship of anatomical biliary tree. (author)

  8. Experimental investigation on enhanced heat transfer of vertical condensers with trisection helical baffles

    International Nuclear Information System (INIS)

    Wu, Jiafeng; Zhou, Jiahao; Chen, Yaping; Wang, Mingchao; Dong, Cong; Guo, Ya

    2016-01-01

    Highlights: • Trisection helical baffles are introduced for vertical condenser enhancement. • Condensation in short-section and intermediate drainage is applied in new schemes. • Helical baffles with liquid dam and drainage gaps can promote condenser performance. • Dual-thread baffle scheme is superior to that of single-thread one by about 19%. • Condensation enhancement ratio of helical schemes is 1.5–2.5 over segment one. - Abstract: The vertical condensers have advantages of small occupation area, convenient in assemble or dismantle tube bundle and simple structure etc. However, the low heat transfer performance limits their applications. To enhance the heat transfer, a novel type of vertical condensers was designed by introducing trisection helical baffles with liquid dams and gaps for facilitating condensate drainage. Four configurations of vertical condensers with trisection helical baffle are experimentally studied and compared to a traditional segment baffle condenser. The enhancement ratio of trisection helical baffle schemes is about 1.5–2.5 and the heat transfer coefficient of the dual-thread trisection helical baffle scheme is superior to that of the single-thread one by about 19%. Assistant by the theoretical study, the experimental data is simulated and the condensation enhancement mechanisms by applying trisection helical baffle in vertical condenser are summarized as condensate drainage, short tube construct and reduce steam dead zone functions of the helical baffles.

  9. Assessment of intraocular foreign bodies by helical-CT multiplanar imaging

    International Nuclear Information System (INIS)

    Papadopoulos, A.; Fotinos, A.; Maniatis, V.; Kavadias, S.; Michaelides, A.; Avouri, M.; Kalamara, C.; Stringaris, K.

    2001-01-01

    The aim of this study was to examine the effectiveness of helical CT in the assessment of intraocular foreign bodies, evaluating two protocols with different collimation. We performed helical-CT studies in 30 patients. Fifteen patients were examined with 1.5-mm collimation and the other 15 patients with 3.0-mm collimation. All other imaging parameters were identical in both protocols. Multiplanar images were reconstructed. The examinations were reviewed for presence, localization and size of intraocular foreign bodies. We compare our results with the surgical data. We estimate the required examination time. In the first group (collimation 1.5 mm) an intraorbital foreign body was detected in 8 of 15 patients. In 3 of 8 patients an intraocular foreign body (all were metallic) was detected. In the second group (collimation 3.0 mm) an intraorbital foreign body was detected in 9 of 15 patients. In 8 of 9 patients an intraocular foreign body (all were metallic) was detected. Our results were confirmed by surgery in all cases. Examination time was 36 s in the first group and 18 s in the second group. Computed tomography should be considered the imaging modality of choice in the assessment of metallic intraocular foreign bodies and 3.0-mm collimation is optional, because of reduced examination time and radiation exposure. (orig.)

  10. Multidetector-row helical CT: analysis of time management and workflow

    Energy Technology Data Exchange (ETDEWEB)

    Roos, Justus E.; Desbiolles, Lotus M.; Willmann, Juergen K.; Weishaupt, Dominik; Marincek, Borut; Hilfiker, Paul R. [Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2002-03-01

    The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min ({+-}2.06 min); (b) 4:36 min ({+-}2.43 min); (c) 4:11 min ({+-}2.55 min); (d) 0:43 min ({+-}0.15 min); (e) 6:59 min ({+-}2.39 min); (f) 09:51 min ({+-}3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and 3:30 min, respectively. Reconstruction time was highest for HRCT (9:22 min) and CTA (9:03 min). Data storage/printing was most time-consuming for HRCT (13:02 min), followed by combined neck-chest-abdomen examinations (12:19 min). Comparing the two time periods, during which a software update was performed, a mean time reduction of 4:31 min per patient (15%, p<0.001) was achieved. Whereas CT data acquisition time is no longer a problem with MDCT, patient management, data reconstruction, and data storage are the most time-consuming parts. Well-trained technicians, state-of-the-art workstations, and fast networking are the most important factors to improve workflow. (orig.)

  11. Metastatic tumor of the pancreas: helical CT findings

    International Nuclear Information System (INIS)

    Lee, Soon Jin; Lee, Won Jae; Lim, Hyo Keun; Kim, Seung Hoon; Kim, Kyeong Ah; Choi, Sang Hee; Jang, Hyun Jung; Lee, Ji Yeon

    2000-01-01

    To analyze the helical computed tomographic (CT) findings of distant metastatic tumors to the pancreas and to determine the differential points between these and primary pamcreatic carcinomas. We sruveyed 22 patients with metastatic tumor of the pancreas, proven on the basis of clinical and pathological findings. Seventeen patients were men, and five were women, and their ages ranged between 36 and 83 years. Their primary conditions were lung cancer (n=3D15), rectal cancer (n=3D2), melanoma of the foot, chondrosarcoma of the sacrum, cervical cancer, leiomyosarcoma of the uterus, and extragonadal choriocarcinoma of the mediastinum. We retrospectively reviewed the abdominal helical CT findings, analysing the number, location, size and attenuation of masses, as well as secondary change, which included dilatation of the pancreatic and biliary ducts and invasion of peripancreatic tissue or vessels. We also evaluated the differential findings of primary pancreatic cancer. Sixteen patients had a solitary focal mass, while in five, two masses were present. Among the 22 patients, low-density nodular masses were present in 21; in the other, in whom multiple metastasis from chondrosarcoma had occurred, there was dense calcification. The size of metastatic masses varied, ranging from 0.6 to 6 cm in diameter. The pancreatic duct proximal to the mass was dilated in ten cases, while the bile duct was dilated in six. The metastatic masses masses demonstrated no peripancreatic or vascular invasion, though they showed a discrete margin and contour bulging. Single metastasis to the pancreas was most common, and metastatic masses had a discrete margin, with contour bulging. There was no peripancreatic or vascular invasion. If the metastasis involved a single low-attenuated mass, however, with pancreatic or biliary dilatation, it was difficult to differentiate this from primary pancreatic cancer. (author)

  12. Helical CT angiography of renal arteries: two-years of experience

    International Nuclear Information System (INIS)

    Beregi, J.P.; Louvegny, S.; Ceugnart, L.; Willoteaux, S.; Elkohen, M.; Desmoucelle, F.; Deklunder, G.; Wattinne, L.

    1997-01-01

    To evaluate the role of helical CT angiography (CTA) in the detection of renal artery stenosis in hypertensive patients. We studied 300 hypertensive patients (50 prospectively and 250 consecutively) with CTA and arteriography (n = 118). Helical acquisition (collimation 3 mm; pitch = 1, 20 seconds acquisition time) was performed 20-45 seconds after contrast injection (300 mgl/ml; 120 ml, 4 ml/sec. Transverse axial views and 3D reconstructions were analysed (360 deg interpolation algorithm, 1 mm overlapped). In the prospective series, CTA sensibility was 100 % for main renal artery stenoses and specificity was 98.2 %; however 7/32 renal accessory arteries were not visualized. In the 300 patients studies, seventy-four stenoses were detected. There were 5 false-positive and 5 false-negative studies. Secondary hypertension was detected in 26 % of patients (including 14 cases of adrenal hyperplasia). CTA is a promising technique for the detection of renal artery stenosis in hypertensive patients. (authors)

  13. Acquiring 4D thoracic CT scans using a multislice helical method

    International Nuclear Information System (INIS)

    Keall, P J; Starkschall, G; Shukla, H; Forster, K M; Ortiz, V; Stevens, C W; Vedam, S S; George, R; Guerrero, T; Mohan, R

    2004-01-01

    Respiratory motion degrades anatomic position reproducibility during imaging, necessitates larger margins during radiotherapy planning and causes errors during radiation delivery. Computed tomography (CT) scans acquired synchronously with the respiratory signal can be used to reconstruct 4D CT scans, which can be employed for 4D treatment planning to explicitly account for respiratory motion. The aim of this research was to develop, test and clinically implement a method to acquire 4D thoracic CT scans using a multislice helical method. A commercial position-monitoring system used for respiratory-gated radiotherapy was interfaced with a third generation multislice scanner. 4D cardiac reconstruction methods were modified to allow 4D thoracic CT acquisition. The technique was tested on a phantom under different conditions: stationary, periodic motion and non-periodic motion. 4D CT was also implemented for a lung cancer patient with audio-visual breathing coaching. For all cases, 4D CT images were successfully acquired from eight discrete breathing phases, however, some limitations of the system in terms of respiration reproducibility and breathing period relative to scanner settings were evident. Lung mass for the 4D CT patient scan was reproducible to within 2.1% over the eight phases, though the lung volume changed by 20% between end inspiration and end expiration (870 cm 3 ). 4D CT can be used for 4D radiotherapy, respiration-gated radiotherapy, 'slow' CT acquisition and tumour motion studies

  14. Three-dimensional helical (spiral) CT angiography. Visualization of vessels in the maxillofacial regions

    International Nuclear Information System (INIS)

    Hanawa, Shigeo; Sakamoto, Hidetomo; Mori, Shin-ichiro; Kagawa, Toyohiro; Seze, Ryosuke; Ishioka, Hisakazu; Tashiro, Himiko; Ogawa, Kazuhisa; Wada, Tadako

    1998-01-01

    Authors performed the contrast helical CT for tumors on the maxillofacial regions, and reconstituted these data into the three-dimensional helical (spiral) CT angiography (CTA). Furthermore the conditions of photographing and the clinical significance of CTA were discussed. The subjects were 24 cases (including 13 of malignant tumors, 4 of benign tumors, 4 of inflammation and 3 of malformations), to which the contrast helical CT was performed transvenously. The photographing condition was set in principal to 140 kV of the tube voltage, 160 (200) mA of the tube current, 3 mm of the X-ray beam width, 3 mm/sec (pitch=1) of the turn-table moving speed. The relationship between the beam width and the pitch was determined by the phantom experiments. The scanning was carried out maximally for continuous 60 sec as the scanning time of a turn/sec. Of all cases, CTA visualized three-dimensionally vessels, but it was hard in the total carotid arteries and the internal-external carotid arteries. Authors analyzed the axial and the multiplanar reconstitution (MPR) images as the two-dimensional display, and the surface rendering (SR), the volume rendering and the maximum intensity projections (MIP) as the three-dimensional display. The axial and MPR image of the facial arteries and the lingual arteries as the branched vessels from the external carotid arteries were recognized easily. By SR, it was easily to understand the anatomical relationship among vessels, gnathic bone and cervical vertebrae, and by MIP sufficiently observe the concentration dependent calcification of the vessel walls. Three-dimensional CTA is very useful to get the three-dimensional visual information about the anatomical structures of the maxillofacial regions which is necessary for oral surgeons to plan the pre-operational strategies. (K.H.)

  15. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  16. Determination of optimal parameters for three-dimensional reconstruction images of central airways using helical CT

    International Nuclear Information System (INIS)

    Hirose, Takahumi; Akata, Soichi; Matsuno, Naoto; Nagao, Takeshi; Abe, Kimihiko

    2002-01-01

    Three-dimensional (3D) image reconstruction of central airways using helical CT requires several user-defined parameters that exceed the requirements of conventional CT. The purpose of this study was to evaluate the optimal parameters for 3D images of central airways using helical CT. In our experimental study using a piglet immediately after sacrifice, 3D images of the central airway were evaluated with changes of 3D imaging parameters, such as detector collimation (1, 2, 3 and 6 mm), table speed (1, 2, 3 and 5 mm/sec), tube electric current (50, 100, 150, 200 and 250 mA), reconstruction interval (0.3, 0.5, 1, 2 and 3 mm), algorithm (mediastinum and lung) and interpolation method (180 deg and 360 deg). To minimize detector collimation, table speed, and reconstruction interval could provide the best 3D images of the central airway. Stair-step artifacts could also be reduced with a slow table speed. However, decreasing the collimation and table speed decreases not only the effective section thickness but also the scan coverage that can be achieved with a helical CT. For routine diagnosis, we conclude that optimal parameters for 3D images of the central airway are to minimize the table speed necessary to cover the volume of interest and to set detector collimation to 1/2 of the table speed. The reconstruction intervals should also be selected at up to 1/2 of the detector collimation, but with trade-offs of increased image processing time, data storage requirements, and physician time for image review. Regarding to tube electric current, 200 mA or more was necessary. Pixel noise increased with the algorithm for the lung. The 180 deg interpolation is better than 360 deg interpolation due to thin effective section thickness. (author)

  17. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  18. The helical three-dimensional CT in the diagnosis of torticollis with occipitocondylar hypoplasia

    International Nuclear Information System (INIS)

    Ilkko, E.; Tikkakoski, T.; Pyhtinen, J.

    1998-01-01

    Congenital anomalies of the atlanto-occipital and atlantoaxial joints are rare. Those most commonly reported are atlantoaxial instability, basilar impression, anomalies of the odontoid process, laxity of the transverse atlantal ligament and atlanto-occipital fusion. Occipital condylar hypoplasia is infrequent and difficult to recognise. We recently diagnosed it using helical 3D CT in association with torticollis in two patients. The first patient had a several year history of torticollis. The second patient had acute cervical lymphadenitis associated with post-operative torticollis. 3D CT distinctly revealed atlantoaxial subluxation with hypoplasia of the occipital condyles in both cases

  19. SU-E-I-93: Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet

    International Nuclear Information System (INIS)

    Nam, H; Guo, M; Lee, K; Li, R; Xing, L; Gao, H

    2014-01-01

    Purpose: Inspired by compressive sensing, sparsity regularized iterative reconstruction method has been extensively studied. However, its utility pertinent to multislice helical 4D CT for radiotherapy with respect to imaging quality, dose, and time has not been thoroughly addressed. As the beginning of such an investigation, this work carries out the initial comparison of reconstructed imaging quality between sparsity regularized iterative method and analytic method through static phantom studies using a state-of-art 128-channel multi-slice Siemens helical CT scanner. Methods: In our iterative method, tensor framelet (TF) is chosen as the regularization method for its superior performance from total variation regularization in terms of reduced piecewise-constant artifacts and improved imaging quality that has been demonstrated in our prior work. On the other hand, X-ray transforms and its adjoints are computed on-the-fly through GPU implementation using our previous developed fast parallel algorithms with O(1) complexity per computing thread. For comparison, both FDK (approximate analytic method) and Katsevich algorithm (exact analytic method) are used for multislice helical CT image reconstruction. Results: The phantom experimental data with different imaging doses were acquired using a state-of-art 128-channel multi-slice Siemens helical CT scanner. The reconstructed image quality was compared between TF-based iterative method, FDK and Katsevich algorithm with the quantitative analysis for characterizing signal-to-noise ratio, image contrast, and spatial resolution of high-contrast and low-contrast objects. Conclusion: The experimental results suggest that our tensor framelet regularized iterative reconstruction algorithm improves the helical CT imaging quality from FDK and Katsevich algorithm for static experimental phantom studies that have been performed

  20. ECG-triggered MDR-CT for the detection of pulmonary metastases

    International Nuclear Information System (INIS)

    Pauls, S.; Wahl, J.; Aschoff, A.J.; Brambs, H.J.; Fleiter, T.R.

    2003-01-01

    Purpose: Comparison of multidetector-row CT (MDR-CT) of the chest with and without ECG triggering for the detection of pulmonary metastases. Materials and Methods: Fifty patients with malignant tumors underwent CT of the chest. The unenhanced phase was performed with ECG-triggered MDR-CT and the contrast-enhanced phase with helical MDR-CT. The ECG-triggered and standard helical scans were interpreted in separate sessions, with the analysis determining the number and demarcation of the intrapulmonary nodules and the delineation of the mediastinal structure (rated 1 = excellent to 5 = poor). Results: ECG-MDR-CT images detected 38% more pulmonary nodules than MDR-CT. The detection rate for tumors [de

  1. Prospective comparison of helical CT with angiography in pulmonary embolism: global and selective vascular territory analysis. Interobserver agreement

    International Nuclear Information System (INIS)

    Ruiz, Yolanda; Caballero, Paloma; Caniego, Jose Luis; Friera, Alfonsa; Olivera, Maria Jose; Tagarro, David; Alvarez-Sala, Rodolfo

    2003-01-01

    The objective of this prospective study was to evaluate the sensitivity, specificity, positive and negative predictive values, and interobserver agreement in the diagnosis of pulmonary embolism with helical CT, compared with pulmonary angiography, for both global results and for selective vascular territories. Helical CT and pulmonary angiography were performed on 66 consecutive patients with clinical suspicion of pulmonary embolism. The exams were blindly interpreted by a vascular radiologist and by two independent thoracic radiologists. Results were analyzed for the final diagnosis as well as separately for 20 different arterial territories in each patient. Pulmonary angiography revealed embolism in 25 patients (38%); 48% were main, 28% lobar, 16% segmental, and 8% subsegmental. The sensitivity, specificity, and positive and negative predictive values of helical CT for observer 1 were, respectively, 91, 81.5, 75, and 94%; in 7.5% of the patients the exam was considered indeterminate. For observer 2 the values were, respectively, 88, 86, 81.5, and 91%; in 9% of the patients the exam was considered indeterminate. Main arteries were considered as non-valuable in 0-0.8%, the lobar in 1.5%, the segmental in 7.5-8.5%, and the subsegmental in 55-60%. Interobserver agreement for the final diagnosis was 80% (kappa 0.65). For each vascular territory, this was 98% (kappa 0.91) for main arteries, 92% (kappa 0.78) for lobar arteries, 79% (kappa 0.56) for segmental arteries, and 59% (kappa 0.21) for subsegmental arteries. Helical CT is a reliable method for pulmonary embolism diagnosis, with good interobserver agreement for main, lobar, and segmental territories. Worse results are found for subsegmental arteries, with high incidence of non-valuable branches and poor interobserver agreement. (orig.)

  2. Hepatic parenchymal perfusion abnormalities after pancreaticobiliary surgery. Evaluation with dynamic helical CT

    International Nuclear Information System (INIS)

    Mitsuzaki, K.; Yamashita, Y.; Ogata, I.; Nishiharu, T.; Urata, J.; Takahashi, M.

    1998-01-01

    Purpose: To evaluate perfusion abnormalities of the liver after pancreaticobiliary surgery. Material and Methods: We retrospectively evaluated 128 patients with pancreaticobiliary malignant tumors who had been examined both before and after surgery by means of helical CT of the liver. An infusion of 3 ml/s of 60% nonionic contrast material was followed by helical CT of the liver in a sequential arterial phase, portal venous phase, and equilibrium phase. Results: Of 128 patients, we followed 97. In 21 patients (22%) we found 47 lesions with perfusion abnormalities that were detected 1-33 months (mean 6.6 months) after the operation. All patients were asymptomatic. The shape of each perfusion abnormality was characterized as geographic (n=23, 47%), wedge-shaped (n=21, 45%), or round (n=3, 8%). The abnormalities were seen in the arterial phase in 46 lesions (98%), in the portal venous phase in 18 lesions (38%), and in the equilibrium phase in 1 lesion (0.2%). In all lesions, the size either decreased spontaneously, or it remained unchanged for more than one year. Conclusion: Perfusion abnormalities of the liver may occur in patients who undergo pancreaticobiliary surgery. These findings should not be confused with hypervascular metastases. (orig.)

  3. Hepatic parenchymal perfusion abnormalities after pancreaticobiliary surgery. Evaluation with dynamic helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsuzaki, K.; Yamashita, Y.; Ogata, I.; Nishiharu, T.; Urata, J.; Takahashi, M. [Kumamoto Univ., School of Medicine, Dept. of Radiology (Japan)

    1998-05-01

    Purpose: To evaluate perfusion abnormalities of the liver after pancreaticobiliary surgery. Material and Methods: We retrospectively evaluated 128 patients with pancreaticobiliary malignant tumors who had been examined both before and after surgery by means of helical CT of the liver. An infusion of 3 ml/s of 60% nonionic contrast material was followed by helical CT of the liver in a sequential arterial phase, portal venous phase, and equilibrium phase. Results: Of 128 patients, we followed 97. In 21 patients (22%) we found 47 lesions with perfusion abnormalities that were detected 1-33 months (mean 6.6 months) after the operation. All patients were asymptomatic. The shape of each perfusion abnormality was characterized as geographic (n=23, 47%), wedge-shaped (n=21, 45%), or round (n=3, 8%). The abnormalities were seen in the arterial phase in 46 lesions (98%), in the portal venous phase in 18 lesions (38%), and in the equilibrium phase in 1 lesion (0.2%). In all lesions, the size either decreased spontaneously, or it remained unchanged for more than one year. Conclusion: Perfusion abnormalities of the liver may occur in patients who undergo pancreaticobiliary surgery. These findings should not be confused with hypervascular metastases. (orig.).

  4. Demonstration of the right inferior phrenic artery by using multislice helical CT

    International Nuclear Information System (INIS)

    Zhao Shaohong; Liu Xin; Cai Zulong; Zhao Hong; Yang Li

    2006-01-01

    Objective: To demonstrate the origin of the right inferior phrenic artery (RIPA) in normal and hepatocellular carcinoma (HCC) patients and provide valuable anatomical information for angiographers before and after transcatheter arterial chemoembolization (TACE). Methods: Four hundred and forty consecutive patients including 133 HCC cases who had biphase abdominal CT were assessed in this study. The routine abdominal enhanced CT scan (GE, LightSpeed16) was performed with 120 kV, 200-240 mAs, 10 mm collimation, 1.375 pitch, and 10 mm reconstruction interval at 22-25 seconds for arterial phase triggered by timing bolus, 60 seconds for portal venous phase after injection of 100 ml contrast material (300 mg I/ml) at a rate of 3.5 ml/s. Multiplanar reconstruction (MPR) and maximum intensity projection (MIP) images were generated using 1.25 mm images reconstructed with 1 mm interval in arterial phase and reviewed by two radiologists. An enhanced artery medial-posterior to the IVC, originated from aorta or its branches to the diaphragmatic dome was interpreted as the RIPA. Results: The RIPA was showed in all 440 patients (100%). Among 218 (49.5%) RIPAs originated from the aorta, 140 were from the fight side of the aorta, 22 from the left side of the aorta, 56 from the anterior wall of the aorta, 36 RIPAs had the same origin with the left inferior phrenic artery. Among 138 (31.4%) RIPAs from the celiac artery, 10 RIPAs had the same origin with the left gastric artery, and 33 RIPAs had the same origin with the left inferior phrenic artery. 78 (17.7%) were from the fight renal artery, 6 (1.4%) were from the left gastric artery (the left gastric artery from aorta). The dilatation of the RIPA was demonstrated in 16 of 133 hepatocellular carcinoma patients. Conclusion: Multislice helical CT could demonstrate the origin of the RIPA in arterial phase and provide useful anatomical information for angiographer before and after TACE. (authors)

  5. The helical three-dimensional CT in the diagnosis of torticollis with occipitocondylar hypoplasia

    International Nuclear Information System (INIS)

    Ilkko, E.; Tikkakoski, T.; Pyhtinen, J.

    1998-01-01

    Congenital anomalies of the atlanto-occipital and atlantoaxial joints are rare. Those most commonly reported are atlantoaxial instability, basilar impression, anomalies of the odontoid process, laxity of the transverse atlantal ligament and atlanto-occipital fusion. Occipital condylar hypoplasia is infrequent and difficult to recognise. We recently diagnosed it using helical 3D CT in association with torticollis in two patients. The first patient had a several year history of torticollis. The second patient had acute cervical lymphadenitis associated with post-operative torticollis. 3D CT distinctly revealed atlantoaxial subluxation with hypoplasia of the occipital condyles in both cases. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  6. Motion tolerant iterative reconstruction algorithm for cone-beam helical CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hisashi; Goto, Taiga; Hirokawa, Koichi; Miyazaki, Osamu [Hitachi Medical Corporation, Chiba-ken (Japan). CT System Div.

    2011-07-01

    We have developed a new advanced iterative reconstruction algorithm for cone-beam helical CT. The features of this algorithm are: (a) it uses separable paraboloidal surrogate (SPS) technique as a foundation for reconstruction to reduce noise and cone-beam artifact, (b) it uses a view weight in the back-projection process to reduce motion artifact. To confirm the improvement of our proposed algorithm over other existing algorithm, such as Feldkamp-Davis-Kress (FDK) or SPS algorithm, we compared the motion artifact reduction, image noise reduction (standard deviation of CT number), and cone-beam artifact reduction on simulated and clinical data set. Our results demonstrate that the proposed algorithm dramatically reduces motion artifacts compared with the SPS algorithm, and decreases image noise compared with the FDK algorithm. In addition, the proposed algorithm potentially improves time resolution of iterative reconstruction. (orig.)

  7. The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers

    International Nuclear Information System (INIS)

    De Rosa, V.; Ziviello, M.; Ionna, F.; Mozzillo, N.; Parascandolo, S.

    2000-01-01

    Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT images were obtained preoperatively and at least 6 months postoperatively in all patients. The images were generated on a computer workstation using the shaded surface display (SSD) software with threshold values ranging 425 to 630 HU, and a more closed window for the imaging of titanium mesh/bone interface in the post surgical follow-up. It was obtained an excellent complete spatial depiction of maxillo facial region both before and after surgery, with no artefacts so important as to affect the 3D reconstruction process and the image quality. Together with the head-neck surgical team it could be worked for preoperative planning through CT scans by different 3D points of view. The 3D reconstructed follow-up scans showed good filling of the defect in the area where the titanium mesh had been used. Then efficacious bone modelling and good biocompatibility of the alloplastic material were seen in all patients, with no inflammatory reactions. Titanium is a well-known material, which is widely used for cranioplasty. It is a radiolucent, non

  8. Intravenous digital subtraction angiography and helical computed tomography in evaluation of living renal donors

    International Nuclear Information System (INIS)

    Watarai, Yoshihiko; Usuki, Tomoaki; Takeuchi, Ichiro; Nonomura, Katsuya; Koyanagi, Tomohiko; Kubo, Kozo; Hirano, Tetsuo; Togashi, Masaki; Ohashi, Nobuo

    2001-01-01

    The present study was carried out to evaluate the accuracy of helical computed tomography (CT) and intravenous digital subtraction angiography (IV-DSA) on anatomical assessment of renal vasculature for living renal donors. Forty-two healthy potential renal donors were prospectively evaluated and 35 subsequently underwent donor nephrectomy after helical CT and IV-DSA evaluation. The vascular and non-vascular findings were compared between the findings on helical CT, IV-DSA and surgery. Ten prehilar branches and five accessory renal arteries were found at nephrectomy. Overall, operative findings agreed with the findings by IV-DSA in 89% and by helical CT in 83%. In delineating accessory arteries, IV-DSA had a sensitivity of 60% and specificity of 97%, whereas helical CT had a sensitivity of 40% and specificity of 100%. In delineating prehilar branches, IV-DSA had a sensitivity of 90% and specificity of 100%, whereas helical CT had a sensitivity of 70% and specificity of 100%. Accessory arteries and prehilar branches that were not detected by helical CT or IV-DSA, were less than 2 mm in diameter and did not require vascular reconstruction. Renal veins were delineated in 63% by IV-DSA, whereas they were clearly imaged by helical CT in all cases, including a case with a circumaortic renal vein. Non-vascular findings were obtained in 64% by helical CT, including two renal tumors. None of these findings were obtained by IV-DSA. Helical CT and IV-DSA provide comparably sufficient information on renal artery vasculature. However, helical CT provides significantly more information on venous and non-vascular findings as a single-imaging modality. (author)

  9. The significance of multi-slice helical CT multiplanar reconstruction in the diagnoses of laryngeal carcinoma

    International Nuclear Information System (INIS)

    Li Lin; Luo Dehong; Zhou Chunwu; Zhao Xinming; Jiang Liming; Huang Yao; Jiang Lingxia; Li Jing; Wu Ning

    2006-01-01

    Objective: To evaluate the significance of multi-slice helical CT with multiplanar reconstruction in laryngeal carcinoma. Methods: Thirty-five patients with laryngeal carcinoma were studied by helical CT, MPR were subsequently done. The lesion extent of the axial image findings, MPR findings and the combined image findings were compared with the pathological results respectively. The data were statistically analyzed. Results: In the evaluation of the anterior commissure, the axial image findings, MPR findings and the combined image findings were 82.9%, 68.6% and 91.4% in accuracy respectively, the results were statistically different (P 0.05). The combined images were superior to the axial images and the MPR images in sensitivity, specificity and accuracy of the lesion extent. Conclusion: The axial images could show the shape, size, extension of the tumor and the lymphadenopathy, MPR images displayed the shape, size and extension roundly and directly, they were the supplement for the axial images. Axial images combined with MPR could improve the accuracy in the diagnoses of laryngeal carcinoma. (authors)

  10. The prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint in patients with mandibular prognathism without internal derangement. MR and helical CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Takafumi; Ito, Jusuke; Tanaka, Rei; Koyama, Jun-ichi; Kobayashi, Fukiko [Niigata Univ. (Japan). Graduate School of Medical and Dental Sciences

    2002-06-01

    The aim of this study was to assess the prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint without internal derangement. Sixty joints of 30 consecutive patients with mandibular prognathism were evaluated with both MR imaging and helical CT. On MPR images obtained with helical CT, erosive osseous changes of the articular eminence were observed in 18 joints (30%) of 13 patients. None of the joints studied demonstrated an osseous change in the mandibular condyle. MR imaging failed to detect erosive osseous changes of the articular eminence in all of the joints studied. In conclusion, MPR images obtained with helical CT were of value to detect erosive osseous changes of the articular eminence. (author)

  11. The prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint in patients with mandibular prognathism without internal derangement. MR and helical CT findings

    International Nuclear Information System (INIS)

    Hayashi, Takafumi; Ito, Jusuke; Tanaka, Rei; Koyama, Jun-ichi; Kobayashi, Fukiko

    2002-01-01

    The aim of this study was to assess the prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint without internal derangement. Sixty joints of 30 consecutive patients with mandibular prognathism were evaluated with both MR imaging and helical CT. On MPR images obtained with helical CT, erosive osseous changes of the articular eminence were observed in 18 joints (30%) of 13 patients. None of the joints studied demonstrated an osseous change in the mandibular condyle. MR imaging failed to detect erosive osseous changes of the articular eminence in all of the joints studied. In conclusion, MPR images obtained with helical CT were of value to detect erosive osseous changes of the articular eminence. (author)

  12. Usefulness of the helical CT in gastro intestinally caused acute abdomen

    International Nuclear Information System (INIS)

    Cruz, R. A. de la; Martel, J.; Albillos, J. C.; Oliver, J. M.; Lopez, J.; Trapero, M. A.

    2000-01-01

    At present, there is a vivid debate on the role of the Helical CT (HCT) in the acute abdomen, principally on the usefulness of the non contrast HCT. We aim to present the most common semiological findings and the differential diagnoses, and to give a short description of the indications and protocols, according to the existing literature and to our experience with HCT during the last three years. We believe that the generalization of the use of HCT in emergencies avoid unnecessary surgery and shorten observation times on many occasions, with clear benefits in the clinical management of the patients. (Author) 30 refs

  13. Helical CT for lung-cancer screening. 3. Fundamental study for ultra-low-dose CT by application of small tube current and filter

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Koyama, Shuji; Tusaka, Masatoshi; Maekoshi, Hisashi; Satake, Hiroko; Ishigaki, Takeo.

    1996-01-01

    In order to develop ultra-low-dose helical CT for lung cancer screening, the effect of reduction of the tube current to 20 mA and application of a 10 mm thick aluminium filter upon radiation dose and image quality was evaluated with a phantom. Exposure dose at the center of a gantry and absorbed dose at the center of an acrylic phantom at 20 mA with the filter were 15% and 29% of the dose at 50 mA without the filter, respectively. For reduction of absorbed dose, reduction of the tube current was more useful than application of the filter. Image noise at 20 mA with the filter was double that at 50 mA without the filter. Neither reduction of the tube current nor application of the filter changed full width at half maximum on section sensitivity of the Z-axis. Although reduction of the tube current did not affect the difference in CT values between an acrylic sphere and styroform, application of the filter caused a reduction of 4.5% in the difference in CT values. Neither reduction of the tube current nor application of the filter affected the contrast resolution of the high-contrast phantom; however, that of the low-contrast phantom deteriorated. Although improvement of the filter and evaluation of clinical images are necessary, reduction of the tube current to 20 mA and application of the aluminium filter appear to be a promising method for ultra-low-dose helical CT of the lung. (author)

  14. Optimization of multi-slice helical respiration-correlated CT: the effects of table speed and rotation time

    International Nuclear Information System (INIS)

    Wink, Nicole M; McNitt-Gray, Michael F; Solberg, Timothy D

    2005-01-01

    While respiration-correlated CT is gaining acceptance in clinical radiotherapy, the effect of scanning parameters on the image quality has yet to be addressed. The intent of this study was to characterize the effects of gantry rotation and table speed on various image quality characteristics in multi-slice, helical, retrospectively-gated CT images. Images of stationary and moving phantoms were obtained in helical mode on a 20-slice CT scanner. Motion was generated by a computer-controlled platform capable of moving simultaneously in two dimensions. Motion was monitored using a pressure gauge inserted inside an adjustable belt. Selected scans were retrospectively gated into ten phases based on the monitored motion. Gantry rotation speeds of 0.5 s and 1.0 s were evaluated with pitches ranging from 0.1 to 0.45. Several parameters, including calculated object volumes, trajectory (movement from peak to trough), deformation (actual volume divided by volume created with the maximum diameter of contoured object) and z-axis resolution, were used to characterize image quality. These studies indicate that for objects in the peak phase of a movement pattern that simulates breathing, retrospectively gated scans using fast gantry rotation speeds produce volume, trajectory, deformation and z-axis resolution results comparable with those of a stationary object

  15. Bladder transitional cell carcinoma: correlation of contrast enhancement on computed tomography with histological grade and tumour angiogenesis

    International Nuclear Information System (INIS)

    Xie, Q.; Zhang, J.; Wu, P.-H.; Jiang, X.-Q.; Chen, S.-L.; Wang, Q.-L.; Xu, J.; Chen, G.-D.; Deng, J.-H.

    2005-01-01

    AIM: To investigate the correlation between the degree of contrast enhancement of bladder cancer in the early enhanced phase of helical computed tomography (CT) and microvessel density (MVD), vascular endothelial growth factor (VEGF) and histological grade. MATERIALS AND METHODS: Sixty-five patients with transitional cell carcinoma of the bladder were examined by incremental unenhanced CT and helical CT at 40-45 s after initiation of intravenous administration of contrast medium before surgery. The CT density in Hounsfield units of bladder carcinomas were measured in the middle of the maximum diameter section of the cancer lesions on unenhanced and enhanced CT. The degree of contrast enhancement of the tumour was determined as the absolute increase in Hounsfield units. Histological grade, VEGF and MVD were analysed for each cancer. The Pearson and Spearman correlation tests were used to determine the strength of the relationships between CT enhancement and histological grade, VEGF expression and MVD. RESULTS: Different degrees of enhancement were observed in 91 cancers during the early enhanced phase of helical CT. Mean MVDs and mean CT enhancing values of different histological grade groups were statistically different (p<0.001). A positive correlation was found in the CT-enhancing value of bladder cancer and MVD (Pearson correlation test; r=0.938, p<0.001) and histological grade (Spearman rank correlation; r=0.734, p<0.001). VEGF of bladder cancer did not correlate with the change in CT attenuation (Spearman rank correlation; r=0.087, p=0.410) and MVD (Spearman rank correlation, r=0.103, p=0.330). CONCLUSION: In bladder cancer, the degree of contrast enhancement during the early enhanced helical CT is correlated with the MVD and histological grade of tumour. It is possible that MVD is the histopathological basis of early contrast enhancement of bladder cancer

  16. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Science.gov (United States)

    Wu, T.-H.; Liang, C.-H.; Wu, J.-K.; Lien, C.-Y.; Yang, B.-H.; Huang, Y.-H.; Lee, J. J. S.

    2009-07-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18F-fluorodeoxyglucose (18F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  17. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    International Nuclear Information System (INIS)

    Wu, T-H; Liang, C-H; Wu, J-K; Lien, C-Y; Yang, B-H; Lee, J J S; Huang, Y-H

    2009-01-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18 F-fluorodeoxyglucose ( 18 F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  18. Detection of hepatocellular carcinoma by Gd-EOB-DTPA-enhanced liver MRI: Comparison with triple phase 64 detector row helical CT

    International Nuclear Information System (INIS)

    Akai, Hiroyuki; Kiryu, Shigeru; Matsuda, Izuru; Satou, Jirou; Takao, Hidemasa; Tajima, Taku; Watanabe, Yasushi; Imamura, Hiroshi; Kokudo, Norihiro; Akahane, Masaaki; Ohtomo, Kuni

    2011-01-01

    Purpose: To compare the diagnostic performance of Gd-EOB-DTPA-enhanced MRI with that of triple phase 64-MDCT in the detection of hepatocellular carcinoma (HCC). Patients and methods: Thirty-four patients with 52 surgically proven lesions underwent Gd-EOB-DTPA-enhanced MRI and triple phase 64-MDCT. Two observers independently evaluated MR and CT imaging on a lesion-by-lesion basis. Sensitivity, positive and negative predictive values and reproducibility were evaluated. The diagnostic accuracy of each modality was assessed with alternative-free response receiver operating characteristic (ROC) analysis. Results: Both observers showed higher sensitivity in detecting lesions with MRI compared to CT, however, only the difference between the two imaging techniques for observer 2 was significant (P = 0.034). For lesions 1 cm or smaller, MRI and CT showed equal sensitivity (both 62.5%) with one observer, and MRI proved superior to CT with the other observer (MRI 75% vs. CT 56.3%), but the latter difference was not significant (P = 0.083). The difference in positive and negative predictive value between the two imaging techniques for each observer was not significant (P > 0.05). The areas under the ROC curve for each observer were 0.843 and 0.861 for MRI vs. 0.800 and 0.833 for CT and the differences were not significant. Reproducibility was higher using MRI for both observers, but the result was not significant (MRI 32/33 vs. CT 29/33, P = 0.083). Conclusion: Gd-EOB-DTPA-enhanced MRI tended to show higher diagnostic accuracy, sensitivity and reproducibility compared to triple phase 64-MDCT in the detection of hepatocellular carcinoma, however statistical significance was not achieved.

  19. COMPUTED TOMOGRAPHY DOSE INDEX MEASUREMENT FOR Hi-ART MEGAVOLTAGE HELICAL CT.

    Science.gov (United States)

    Liu, Minglu; Wang, Yunlai; Liao, Xiongfei

    2016-11-01

    On-line megavoltage computed tomography (MVCT) images are used to verify patient daily set-up in Hi-ART helical TomoTherapy unit. To evaluate the patient dose from MVCT scanning in image guidance, weighted computed tomography (CT) dose index (CTDI w ) was measured with PTW TM30009 CT pencil chamber in head and body phantoms for slice thicknesses of 2, 4 and 6 mm with different scan lengths. Dose length products (DLPs) were subsequently calculated. The CTDI w and DLP were compared with XVI kV CBCT and Brilliance simulator CT for routine clinical protocols. It was shown that CTDI and DLP had close relationship with the slice thickness and the scan length. The dose distribution in the transversal plane was very inhomogeneous due to the attenuation of the couch. Patient dose from MVCT was lower than XVI CBCT for the head scan, while larger for body scan. CTDI w , which is measured easily and reproducibly, can be used to assess the patient dose in MVCT. Regular measurement should be performed in QA & QC programmes. Appropriate slice thickness and scan range should be chosen to reduce the patient dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. The efficacy of low-dose helical CT screening as an option for health examination

    International Nuclear Information System (INIS)

    Kishi, Kazuma; Hara, Shigeko; Kurosaki, Atsuko; Fujii, Takeshi; Yoshimura, Kunihiko

    2007-01-01

    We retrospectively evaluated the results of low-dose helical CT screening as an option for health examinations. From November 2002 to October 2005, CT screening was performed in 2,306 individuals (men 1,766, women 540, mean age 56.1 years). Among them, 71 individuals (3.1%) were diagnosed as having active thoracic diseases consisting of 14 neoplasms and 57 non-neoplastic diseases. Of 14 patients with neoplastic lesions, 13 had lung cancer, 1 of whom had double primary lung cancer, and 1 had atypical adenomatous hyperplasia. The mean diameter of the 14 lung cancers was 14.4 mm. The histology of these lesions was adenocarcinoma in 13 and squamous cell carcinoma in 1. The pathological stage was IA in 12 patients and IIA in 1. All patients underwent surgical resection. On the other hand, emphysema was diagnosed in 40 asymptomatic individuals based on CT and spirometry, and smoking cessation was strongly implemented for those who were current smokers. CT screening is useful for detecting not only early lung cancer but also non-neoplastic lung diseases. (author)

  1. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  2. Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemoembolization; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo chemioembolizzazione

    Energy Technology Data Exchange (ETDEWEB)

    Catalano, O.; Esposito, M.; Sandomenico, F.; Siani, A. [Ospedale S. Maria delle Grazie, Pozzuoli, NA (Italy). Servizio di Radiologia; Nunziata, A. [Ospedale S. Maria delle Grazie, Naples (Italy). Area di Diagnostica per Immagini

    2000-06-01

    The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to global chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower than 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively homogeneous areas with hyper attenuation in the arterial phase and hypo-iso attenuation in the portal and/or delayed phase, or with hypo-iso attenuation in the arterial phase and in the portal and/or delayed phase. Lipiodol CT permitted to recognize 65 nodules (1-5/patient, mean 1.5), namely 15 grade I, 21 grade II, 20 grade III and 9 grade IV. Multiphase CT identified 6 additional nodules in 5 patients, 5 hyper vascular and 1 hypo vascular, and better assessed the correct morphology and volume of grade I nodules. Only 4 of 6 nodules missed on Lipiodol CT showed oily agent uptake after a new chemo embolization session. Moreover after retreatment, carried out in 6 of 9 patients with grade I uptake (11 nodules in all), it has been found persistence of the grade I pattern in 5 nodules, grade II in 5, and grade III in 1. Lipiodol CT may miss liver nodules and underestimate the volume of nodules with poor uptake. Though Lipiodol CT should still be considered slightly more sensitive than multiphase CT, in the general opinion this

  3. Incidental diagnosis of diseases on un-enhanced helical computed tomography performed for ureteric colic

    Directory of Open Access Journals (Sweden)

    Ather M Hammad

    2003-03-01

    Full Text Available Abstract Background Patients presenting in the emergency room with flank pain suggestive of acute ureteric colic may have alternative underlying conditions mimicking ureteric stones. An early diagnosis and appropriate treatment for other causes of flank pain is important. The majority of centers around the world are increasingly using un-enhanced helical CT (UHCT for evaluation of ureteric colic. This study was conducted to determine the incidence and spectrum of significant incidental diagnoses established or suggested on UHCT performed for suspected renal/ureteric colic. Methods Urologist and radiologist reviewed 233 consecutive UHCT, performed for suspected renal/ureteral colic along with assessment of the medical records. Radiological diagnoses of clinical entities not suspected otherwise were analyzed. All other relevant radiological, biochemical and serological investigations and per-operative findings were also noted. Results Ureteral calculi were identified in 148 examinations (64%, findings of recent passage of calculi in 10 (4% and no calculus in 75 examinations (32%. Overall the incidental findings (additional or alternative diagnosis were found in 28 (12% CT scans. Twenty (71% of these diagnoses were confirmed by per-operative findings, biopsy, and other radiological and biochemical investigations or on clinical follow up. Conclusion A wide spectrum of significant incidental diagnoses can be identified on UHCT performed for suspected renal/ureteral colic. In the present series of 233 consecutive CT examinations, the incidence of incidental diagnosis was 12%.

  4. The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Lee, Ho Kyu; Choi, Choong Gon; Suh, Dae Chul; Lim, Tae Hwan; Kang, Weechang

    2002-01-01

    To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased

  5. Comparison between helical computed tomography angiography and intraoperative findings

    Directory of Open Access Journals (Sweden)

    Abijit Shetty

    2014-01-01

    Conclusions: Helical CT is important in delineating the arterial, venous, and ureteral anatomy and can show the important incidental findings. Left renal donors and males have more variations in their renal anatomy. Technically challenging laparoscopic nephrectomy on the multiple-vessel-side donor is possible with the aid of helical CT. The importance of the CT in evaluating donor renal anatomy for a technically challenging laparoscopic donor nephrectomy is commendable.

  6. Virtual endoscopy post-processing of helical CT data sets

    International Nuclear Information System (INIS)

    Dessl, A.; Giacomuzzi, S.M.; Springer, P.; Stoeger, A.; Pototschnig, C.; Voelklein, C.; Schreder, S.G.; Jaschke, W.

    1997-01-01

    Purpose: The purpose of this work was to test a newly developed, post-processing software for virtual CT endoscopic methods. Virtual endoscopic images were generated from helical CT data sets in the region of the shoulder joint (n=2), the tracheobronchial system (n=3), the nasal sinuses (n=2), the colon (n=2), and the common carotid artery (n=1). Software developed specifically for virtual endoscopy ('Navigator') was used which, after a previous threshold value selection, makes the reconstruction of internal body surfaces possible by an automatic segmentation process. We have evaluated the usage of the software, the reconstruction time for individual images and sequences of images as well as the quality of the reconstruction. All pathological findings of the virtual endoscopy were confirmed by surgery. Results: The post-processing program is easy to use and provides virtual endoscopic images within 50 seconds. Depending of the extent of the data set, virtual tracheobronchoscopy as a cine loop sequence required about 15 minutes. Thorugh use of the threshold value-dependent surface reconstruction the demands on the computer configuration are limited; however, this also created quality problems in image calculation as a consequence of the accompanying loss of data. Conclusions: The Navigator software enables the calculation of virtual endoscopic models with only moderate demands on the hardware. (orig.) [de

  7. Three-dimensional CT endoscopic images of the larynx. Clinical application of helical CT

    International Nuclear Information System (INIS)

    Yumoto, Eiji; Sanuki, Tetsuji; Yasuhara, Yoshifumi; Ochi, Takashi

    1998-01-01

    Twenty-seven patients with several laryngeal ailments underwent helical computed tomography (CT) on 37 occasions. Ten of these 27 patients suffered from unilateral vocal fold paralysis (UVFP). Three-dimensional (3D) images of the laryngeal lumen viewed from various angles were produced for all sets of CT volumetric data, except for three which contained excessive motion artifacts. The present paper examined whether 3D endoscopic images could offer useful diagnostic and therapeutic information about UVFP. The 3D endoscopic images viewed from the tracheal side and the hemilaryngeal images viewed from the opposite side could delineate the vocal folds, ventricular fold and ventricle three-dimensionally. Atrophy and hypotonic changes to the vocal fold and expansion of the ventricle on the affected side were clearly shown. The 3D endoscopic images accurately showed the phonosurgical effects on the laryngeal structures. The 3D endoscopic images could be produced even when the vocal folds could not be observed with conventional endoscopy due to their overadduction. Multiplanar reconstruction (MPR) images in the coronal plane were reconstructed at a right angle to the glottic axis when the whole larynx was deviated. In addition, coronal MPR images showed a better resolution among the different layers of the vocal fold soft tissue than X-ray tomography. In conclusion, 3D endoscopic images combined with coronal MPR images can provide useful diagnostic an therapeutic information about UVFP, although motion artifacts may occur. (author)

  8. Effect of CT contrast on volumetric arc therapy planning (RapidArc and helical tomotherapy) for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Alan J.; Vora, Nayana [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States); Suh, Steve [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Liu, An, E-mail: aliu@coh.org [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Schultheiss, Timothy E. [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Wong, Jeffrey Y.C. [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States)

    2015-04-01

    The objectives of the study were to evaluate the effect of intravenous contrast in the dosimetry of helical tomotherapy and RapidArc treatment for head and neck cancer and determine if it is acceptable during the computed tomography (CT) simulation to acquire only CT with contrast for treatment planning of head and neck cancer. Overall, 5 patients with head and neck cancer (4 men and 1 woman) treated on helical tomotherapy were analyzed retrospectively. For each patient, 2 consecutive CT scans were performed. The first CT set was scanned before the contrast injection and secondary study set was scanned 45 seconds after contrast. The 2 CTs were autoregistered using the same Digital Imaging and Communications in Medicine coordinates. Tomotherapy and RapidArc plans were generated on 1 CT data set and subsequently copied to the second CT set. Dose calculation was performed, and dose difference was analyzed to evaluate the influence of intravenous contrast media. The dose matrix used for comparison included mean, minimum and maximum doses of planning target volume (PTV), PTV dose coverage, and V{sub 45} {sub Gy}, V{sub 30} {sub Gy}, and V{sub 20} {sub Gy} organ doses. Treatment planning on contrasted images generally showed a lower dose to both organs and target than plans on noncontrasted images. The doses for the points of interest placed in the organs and target rarely changed more than 2% in any patient. In conclusion, treatment planning using a contrasted image had insignificant effect on the dose to the organs and targets. In our opinion, only CT with contrast needs to be acquired during the CT simulation for head and neck cancer. Dose calculations performed on contrasted images can potentially underestimate the delivery dose slightly. However, the errors of planning on a contrasted image should not affect the result in clinically significant way.

  9. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Maeda, Tetsuo; Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Radiology, Kobe University Hospital, Kobe (Japan); Yoshikawa, Takeshi [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Konishi, Minoru [Division of Radiology, Kobe University Hospital, Kobe (Japan); Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2011-11-15

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect ({kappa} > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  10. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Maeda, Tetsuo; Ohno, Yoshiharu; Yoshikawa, Takeshi; Konishi, Minoru; Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2011-01-01

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect (κ > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  11. Intra-arterial angio-CT for radiosurgery of cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Tanami, Yutaka; Kunieda, Etsuo; Onozuka, Satoshi

    1998-01-01

    Intra-arterial CT-angiograms were performed for four patients undergoing stereotactic radiosurgery for cerebral arteriovenous malformations (AVM). Helical and dynamic CT scans were carried out with a scanner installed in a angiographic examination room following routine angiography. Helical scans were performed with continuous arterial infusion of contrast media. Then, dynamic scans were repeated at several table positions. Subtractions were achieved for a post-embolization case. Normal and pathological vascular structures were demonstrated with different enhancement phases with the dynamic scans. The coordinates of the target points in the nidus could be clearly determined. We concluded that intra-arterial CT-angiograms are practical and useful for treatment planning of radiosurgery for cerebral AVM. (author)

  12. Intra-arterial angio-CT for radiosurgery of cerebral arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Tanami, Yutaka; Kunieda, Etsuo; Onozuka, Satoshi [Keio Univ., Tokyo (Japan) School of Medicine] [and others

    1998-08-01

    Intra-arterial CT-angiograms were performed for four patients undergoing stereotactic radiosurgery for cerebral arteriovenous malformations (AVM). Helical and dynamic CT scans were carried out with a scanner installed in a angiographic examination room following routine angiography. Helical scans were performed with continuous arterial infusion of contrast media. Then, dynamic scans were repeated at several table positions. Subtractions were achieved for a post-embolization case. Normal and pathological vascular structures were demonstrated with different enhancement phases with the dynamic scans. The coordinates of the target points in the nidus could be clearly determined. We concluded that intra-arterial CT-angiograms are practical and useful for treatment planning of radiosurgery for cerebral AVM. (author)

  13. Multiple renal aspergillus abscesses in an AIDS patient: contrast-enhanced helical CT and MRI findings

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kauczor, H.U.; Thelen, M.; Heussel, G.; Jahn, B.

    1999-01-01

    Renal insufficiency or allergic reactions for X-ray contrast agents are frequent limitations in immunocompromised hosts such as neutropenic or AIDS patients. Due to a better tolerance of contrast agents in MRI, this technique is well suited for investigation of parenchymal organs. We demonstrate an allergic AIDS patient who presented with fever and flank pain. At sonography, anechoic renal lesions were supposed to be non-complicated cysts; however, on T2-weighted MRI, the center was of high signal. Dynamic contrast-enhanced MRI of the kidneys demonstrated an enhancing rim with ill-defined margins. The lesions were supposed to be multiple bilateral abscesses. Due to the multiple dynamic contrast series, a delayed enhancement of renal parenchyma was detectable adjacent to the lesion. This was suggested as accompanying local pyelonephritis and an infectious etiology became more reliable. Aspergillus fumigatus was identified by CT-guided biopsy as the underlying microorganism. The MR appearance of this manifestation has not been described previously. (orig.)

  14. Diagnosis of deep vein thrombosis using multi-detector helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya [Wakayama Medical Coll. (Japan)] [and others

    2002-11-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5{+-}7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  15. Diagnosis of deep vein thrombosis using multi-detector helical CT

    International Nuclear Information System (INIS)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya

    2002-01-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5±7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  16. TH-E-17A-02: High-Pitch and Sparse-View Helical 4D CT Via Iterative Image Reconstruction Method Based On Tensor Framelet

    International Nuclear Information System (INIS)

    Guo, M; Nam, H; Li, R; Xing, L; Gao, H

    2014-01-01

    Purpose: 4D CT is routinely performed during radiation therapy treatment planning of thoracic and abdominal cancers. Compared with the cine mode, the helical mode is advantageous in temporal resolution. However, a low pitch (∼0.1) for 4D CT imaging is often required instead of the standard pitch (∼1) for static imaging, since standard image reconstruction based on analytic method requires the low-pitch scanning in order to satisfy the data sufficient condition when reconstructing each temporal frame individually. In comparison, the flexible iterative method enables the reconstruction of all temporal frames simultaneously, so that the image similarity among frames can be utilized to possibly perform high-pitch and sparse-view helical 4D CT imaging. The purpose of this work is to investigate such an exciting possibility for faster imaging with lower dose. Methods: A key for highpitch and sparse-view helical 4D CT imaging is the simultaneous reconstruction of all temporal frames using the prior that temporal frames are continuous along the temporal direction. In this work, such a prior is regularized through the sparsity transform based on spatiotemporal tensor framelet (TF) as a multilevel and high-order extension of total variation transform. Moreover, GPU-based fast parallel computing of X-ray transform and its adjoint together with split Bregman method is utilized for solving the 4D image reconstruction problem efficiently and accurately. Results: The simulation studies based on 4D NCAT phantoms were performed with various pitches (i.e., 0.1, 0.2, 0.5, and 1) and sparse views (i.e., 400 views per rotation instead of standard >2000 views per rotation), using 3D iterative individual reconstruction method based on 3D TF and 4D iterative simultaneous reconstruction method based on 4D TF respectively. Conclusion: The proposed TF-based simultaneous 4D image reconstruction method enables high-pitch and sparse-view helical 4D CT with lower dose and faster speed

  17. Complete opacification of the esophageal lumen using helical (slip-ring) CT scanner with cellulose-barium paste, and its application to the evaluation of the effect of radiation therapy for esophageal cancer

    International Nuclear Information System (INIS)

    Noda, Yoshihiro; Ogawa, Yasuhiro; Nishioka, Akihito; Inomata, Taisuke; Yoshida, Shoji; Toki, Taiichi; Ogoshi, Shohei

    1996-01-01

    The esophageal lumen of patients with esophageal cancer or paraesophageal disorders is frequently impossible to visualize on CT image and, consequently, difficulties in the differentiation of esophageal tumor mass and adjacent organs are often encountered. Therefore, we have developed a safe, high viscous, oral contrast medium which contains carboxy-methyl cellulose sodium (a conventionally used laxative with mild effect and inexpensive) and low-density 2% barium. Helical CT scan using this medium plus intravenous injection of iodine contrast enhancement agent was performed in 24 patients with esophageal cancer or paraesophageal diseases. Complete opacification of the esophageal lumen was obtained for almost all images of the upper, middle and lower thoracic esophagus. This method is easy to use and has not caused any serious side effect so far. We have developed a new oral contrast agent for esophageal helical CT to estimate the volume of tumor on CT images before and after treatment. The therapeutic effect of radiotherapy in 10 patients with esophageal cancer was evaluated using this method. In seven of the 10 patients, the rate of decrease of the esophageal tumor mass during radiotherapy was much lower with our new method than with conventionally used method. Combination of these two methods is essential for the evaluation of the therapeutic effect of radiotherapy for esophageal cancer. (author)

  18. Imaging of Composites by Helical X-Ray Computed Tomography

    DEFF Research Database (Denmark)

    Wang, Ying; Pyka, Grzegorz; Jespersen, Kristine Munk

    Understanding the fatigue damage mechanisms of composite materials used in wind turbine rotor blades could potentially enhance the reliability and energy efficiency of wind turbines by improving the structure design. In this paper, the fatigue damage propagating mechanisms of unidirectional glass...... fibre composites was characterised by helical X-ray CT. The staining approach was used and it was effective to enhance the visibility of thin matrix cracks and partly closed fibre breaks instead of widely opened cracks. Fibre breaks in the centre UD bundle were found to occur locally, instead of being...

  19. The detectability of hepatic metastases in candidates of radiofrequency ablation: comparison for helical CT scanning and late-phase pulse-inversion harmonic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Won; Yoon, Kwon Ha; Kim, Eun A; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [School of Medicine, Wonkwang Univ., Iksan (Korea, Republic of)

    2002-02-01

    To compare dual-phase helical CT and pulse inversion harmonic US using microbubble contrast agents in the detection of hepatic metastases prior to radiofrequency (RF) ablation. Twenty-one patients in whom hepatic metastases from colorectal cancer had been diagnosed by dual-phase CT scanning and who were considered to be candidates for RF ablation underwent pulse-inversion barmonic US examination. Images were obtained 5 minutes after the bolus injection of microbubble contrast agent SH U 508 A (4.0 g, 300 mg/mL). The number of metastatic tumors revealed by CT and US was determined, and the findings were statistically analysed. The influence of the results of US examination on treatment planning was also evaluated. In 21 patients, 48 metastaic lesions were detected by helical CT, and 56 lesions by US. These eight additional lesions revealed by US occurred in six patients (29%), and their diameter was 3-13 (mean, 7.2) mm. In three of these patients, RF ablation could not be performed ,while in the other three, the additional lesions were ablated. Pulse-inversion harmonic US imaging using microbubble contrast agents may depict small hepatic metastatic tumors that were not apparent at CT. US-therefore appears to be useful in the planning of treatment prior to the RF ablation of hepatic metastases.

  20. Evaluation of the retrospective ECG-gated helical scan using half-second multi-slice CT. Motion phantom study for volumetry

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Matsumoto, Takashi; Nakanishi, Shohzoh; Hamada, Seiki; Takahei, Kazunari; Naito, Hiroaki; Ogata, Yuji

    2002-01-01

    ECG synchronized technique on multi-slice CT provide the thinner (less 2 mm slice thickness) and faster (0.5 sec/rotation) scan than that of the single detector CT and can acquire the coverage of the entire heart volume within one breath-hold. However, temporal resolution of multi-slice CT is insufficient on practical range of heart rate. The purpose of this study was to evaluate the accuracy of volumetry on cardiac function measurement in retrospective ECG-gated helical scan. We discussed the influence of the degradation of image quality and limitation of the heart rate in cardiac function measurement (volumetry) using motion phantom. (author)

  1. Aortic non communicating dissections. A study with helical CT; Studio dell'ematoma intramurale aortico. Aspetti con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Midiri, M.; Strada, A.; Stabile Ianora, A.A.; Rotondo, A.; Angelelli, G. [Bari Univ., Bari (Italy). Dipt. di Medicina Interna e Medicina Pubblica, Sez. di Diagnostica per Immagini; Scialpi, M. [Ospedale SS. Annunziata, Taranto (Italy); D' Agostino, D.; De Luca Tupputi Schinosa, L. [Bari Univ., Bari (Italy). Dipt. Emergenze Trapianto d' Organo, Sez. di Cardiochirurgia

    2000-09-01

    The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low density on enhanced images in all patients. Thickening was eccentric in 14/18 patients and concentric in 4/18 only; it always exceeded 4 mm. It was found some intimal calcifications in 8 patients and hemo thorax and/or hemo mediastinum in 9 patients. A patient with type A hematoma died of cardiac tamponade a few hours after CT diagnosis. Six patients (5 type B and 1 type A) underwent anti-hypertensive treatment and radiological follow-up. Eleven patients (6 type A and 5 type B) underwent prosthesis replacement and 5 of them (3 type A and 2 type B) died of postoperative complications. In the 5 type B patients surgery was performed because of treatment-resistant pain and of the onset of ischemic complications to abdominal organs caused by involvement of the main collateral branches of the aorta. One patient with type A hematoma was submitted to drug treatment because it was judged unresectable. Intramural hematoma of the aorta is a distinct pathological entity, which should not be

  2. Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration

    Energy Technology Data Exchange (ETDEWEB)

    Hernalsteen, Danielle; Cosnard, Guy; Grandin, Cecile; Duprez, Thierry [Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Department of Radiology and Medical Imaging, Brussels (Belgium); Robert, Annie [Public Health School, Universite Catholique de Louvain, Department of Epidemiologics and Medical Statistics, Brussels (Belgium); Vlassenbroek, Alain [CT Clinical Science, Philips Medical Systems, Cleveland, OH (United States)

    2007-04-15

    Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous ''native'' 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4 x 0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality. (orig.)

  3. Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration

    International Nuclear Information System (INIS)

    Hernalsteen, Danielle; Cosnard, Guy; Grandin, Cecile; Duprez, Thierry; Robert, Annie; Vlassenbroek, Alain

    2007-01-01

    Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous ''native'' 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4 x 0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality. (orig.)

  4. Contrast enhancement CT by iopamidol

    International Nuclear Information System (INIS)

    Mori, Masaki; Makita, Nobue; Yanai, Kyoko

    1984-01-01

    In order to evaluate the contrast enhancement effect and safety of iopamidol (IOP) in CT examination, IOP was compared with angiographin (AG). In the liver and abdominal aorta, peak CT values were obtained earlier and were higher in the group with AG than in the group with IOP. However, CT values in the group with IOP decreased a little more slowly than those in the group with AG. There was no significant difference in the effect on contrast enhancement between the groups. Intravenous injection of IOP caused lower degree of burning sensation than that of AG, and some of the patients with IOP did not feel burning sensation at all. Changes in clinical laboratory values were slight before and after intravenous injection of IOP. These results suggest that IOP is satisfactory in terms of safety and effect on contrast enhancement in CT examination. (Namekawa, K.)

  5. Contrast enhanced CT of spinal cord angioma

    International Nuclear Information System (INIS)

    Nakamura, Takahiko; Ebitani, Tsutomu; Honma, Takao; Sofue, Muroto; Nakamura, Shigeru

    1982-01-01

    Contrast enhanced CT on 6 patients with spinal cord angioma showed enhancement in 2 of them. The conditions to produce contrast enhancement were the window width of 100 - 200, and the window level of 0 - 50. In spinal cord angioma, contrast enhanced CT is presently only an adjunct to angiography and myelography. Nevertheless, contrast enhanced CT is useful in the screening test for spinal cord angioma, in the patients who are nonindicated to angiography, and in the postoperative follow-up. (Ueda, J.)

  6. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  7. Performance of integrated FDG-PET/contrast-enhanced CT in the staging and restaging of colorectal cancer: Comparison with PET and enhanced CT

    International Nuclear Information System (INIS)

    Dirisamer, Albert; Halpern, Benjamin S.; Floery, Daniel; Wolf, Florian; Beheshti, Mohsen; Mayerhoefer, Marius E.; Langsteger, Werner

    2010-01-01

    Objective: The purpose of this study was to assess the diagnostic value of PET/CT as a one step examination in patients with colorectal cancer. Therefore we proved whether diagnostic PET/CT adds information over PET or contrast-enhanced CT alone for staging or restaging of patients with colorectal cancer. Methods: Seventy-three patients (46 males and 27 females; age range: 50-81 years; mean age: 67 years) with known colorectal cancer underwent 18F-FDG-PET/CT for staging or restaging. Results: Of the 73 patients 26 patients underwent PET/CT for staging and 47 for restaging. 266 metastases could be detected in 60 patients. Contrast-enhanced PET/CT had a lesion-based sensitivity of 100%, contrast-enhanced CT of 91% and PET of 85%. PET/CT identified 2 lesions as false positive. PET/CT could also reach a patient-based sensitivity of 100%, which was superior to contrast-enhanced CT and PET. Conclusion: Our study clearly demonstrated the added value of contrast-enhanced PET/CT in staging and restaging patients with colorectal cancer over CT and PET alone.

  8. Clinical applications for multiplanar- and three-dimensional-reconstructions by helical-CT for the diagnosis of acetabular fractures

    International Nuclear Information System (INIS)

    Stroszczynski, C.; Schedel, H.; Stoeckle, U.; Wellmann, A.; Beier, J.; Wicht, L.; Hoffmann, R.; Felix, R.

    1996-01-01

    This review describes recent visualizations of computed tomography for the diagnosis of acetabular fractures. The techniques of conventional and helical-CT for the imaging of the acetabulum are compared. Furthermore, the different methods of multiplaner and three-dimensional reconstructions e.g. shaded surface display, maximum intensity projection, and volume rendering are presented. Figures of multiplanar and three-dimensional imaging for fractures of the pelvis is discussed. (orig.) [de

  9. Experimental study of quantity to be taken as patient dose in helical multi-slice CT scan

    International Nuclear Information System (INIS)

    Liu Lantao; Wei Kedao; Yue Brorong; Wang Jianchao

    2009-01-01

    Objective: To bring forward a novel quantity which is used to be taken as effective dose in helical multi - slice CT scan and to validate it by experiment. Methods: Dot chamber and pencil-chamber were used to measure the doses which were performed under axial mode and helical multi-slice mode. Then the readings of doses were compared and analyzed. Results: The dose reading from dot chamber was close to the one from pencil - chamber under axial mode. The ratio is 1.14 for the readings from dot chamber under two scan modes and is 2.88 for the readings from pencil-chamber under two scan modes. Conclusions: The dose measured from dot chamber is an effective quantity to be taken as effective dose. However it is insufficient that the CTDI and DLP be used to be taken as effective dose as the limitation of pencil-chamber in length. (authors)

  10. Multislice Helical CT Angiography in Diagnostic of Intracranial and Extracranial Arterial Dissection

    International Nuclear Information System (INIS)

    Radzina, M.; Krumina, G.; Pupols, J.

    2007-01-01

    complete information about arterial extracranial and intracranial vascular system. CTA is highly informative in characterization of dissection site and morphology, also diagnostic of combined brain pathology. Appropriate quality CTA requires high capacity: at least 16 slice helical CT equipment that provides quick examination with wide range of post processing possibilities. Non enhanced brain CT is recommended before CTA, to specify cerebral structural changes and to identify vascular calcified plaques. Indications for intracranial CTA: subarachnoidal hemorrhage, intracerebral hematoma, intraventricular hemorrhage, cerebral infarction; outpatient praxis: stenoses, aneurysms, arteriovenous malformations, cerebral infarction history, vasculitis. Indications for brachiocephalic CTA are: acute head-neck trauma, ischemia; for outpatient praxis: US suspected vessel stenoses, cerebral infarction history. Selected protocol with post process ing opens up new opportunities for further research of most optimized CTA follow up time, evaluation of recanalization, and randomization of patients, angkalcinguldisekcija, for stenting procedures of dissected arterial segment. authors)

  11. Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer

    International Nuclear Information System (INIS)

    Bradley, Jeffrey D.; Nofal, Ahmed N.; El Naqa, Issam M.; Lu, Wei; Liu, Jubei; Hubenschmidt, James; Low, Daniel A.; Drzymala, Robert E.; Khullar, Divya

    2006-01-01

    Background and Purpose: To compare helical, MIP and AI 4D CT imaging, for the purpose of determining the best CT-based volume definition method for encompassing the mobile gross tumor volume (mGTV) within the planning target volume (PTV) for stereotactic body radiation therapy (SBRT) in stage I lung cancer. Materials and methods: Twenty patients with medically inoperable peripheral stage I lung cancer were planned for SBRT. Free-breathing helical and 4D image datasets were obtained for each patient. Two composite images, the MIP and AI, were automatically generated from the 4D image datasets. The mGTV contours were delineated for the MIP, AI and helical image datasets for each patient. The volume for each was calculated and compared using analysis of variance and the Wilcoxon rank test. A spatial analysis for comparing center of mass (COM) (i.e. isocenter) coordinates for each imaging method was also performed using multivariate analysis of variance. Results: The MIP-defined mGTVs were significantly larger than both the helical- (p 0.001) and AI-defined mGTVs (p = 0.012). A comparison of COM coordinates demonstrated no significant spatial difference in the x-, y-, and z-coordinates for each tumor as determined by helical, MIP, or AI imaging methods. Conclusions: In order to incorporate the extent of tumor motion from breathing during SBRT, MIP is superior to either helical or AI images for defining the mGTV. The spatial isocenter coordinates for each tumor were not altered significantly by the imaging methods

  12. Diagnosis value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma

    International Nuclear Information System (INIS)

    Ma Zhoupeng; Zhou Jianjun; Liu Xueling; Wang Chun; Zhang Shunzhuang

    2012-01-01

    Objective: To explore the diagnostic value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma. Methods: Sixty patients who were suspected of clear cell renal cell carcinoma underwent non-enhanced CT and contrast enhancement CT of early interface-phase between cortex -medulla and parenchymal phase on a dual-energy CT. The true non-enhanced kidney CT (TNCT) was performed in a single-energy acquisition mode, but the dual-phase contrast enhancement CT were performed in a dual-energy mode of 80 kV and 140 kV respectively. The virtual non-enhanced CT (VNCT) images were derived from the data of early interface phase using liver virtual non-contrast software. The diagnose according to VNCT combined dual-phase contrast enhancement CT and dual-phase contrast enhancement CT only were made respectively and compared with χ 2 test. Between the true non-contrast CT and the virtual non-contrast CT, the image quality was compared with Wilcoxon test; The radiation dose of volume CT dose index (CTDIvol) and dose length product(DLP) in a single-phase and total examination, the mean CT HU values of the tumours were compared with t test. Results: The accuracy of VNCT combined dual-phase contrast enhancement CT was higher than that of dual-phase contrast enhancement CT only [93.3% (56/60) vs.78.3% (47/60); χ 2 =5.6, P<0.05]. The detective ability (score) of VNCT was near to that of TNCT and the difference was not obvious (Z=0.00, P>0.05). The radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination of VNCT [(8.85 ± 1.28) mGy, (196.45 ±21.12) mGy·cm, (17.69±2.35) mGy, (392.90±42.25) mGy · cm] were lower than that of TNCT [(10.20 ± 1.44) mGy,(218.29 ± 29.60) mGy · cm, (30.61 ± 3.27) mGy and (654.86 ± 88.81) mGy ·cm], t=4.21, 3.58, 23.63, 16.12 respectively, P<0.05. The mean CT HU values of tumours on VNCT images was higher than that

  13. Analysis of aliasing artifacts in 16-slice helical CT

    International Nuclear Information System (INIS)

    Chen Wei; Liu Jingkang; Ou Xiaoguang; Li Wenzheng; Liao Weihua; Yan Ang

    2006-01-01

    Objective: To recognize the features of aliasing artifacts on CT images, and to investigate the effects of imaging parameters on the magnitude of this artifacts. Methods: An adult dry skull was placed in a plastic water-filled container and scanned with a PHILIPS 16-slice helical CT. All the acquired transaxial images by using several different acquisition or reconstruction parameters were examined for comparative assessment of the aliasing artifacts. Results: The aliasing artifacts could be seen in most instances and characterized as the spokewise patterns emanating from the edges of high contrast structure as its radius varies sharply in the longitudinal direction. The images that scanned with pitch of 0.3, 0.6 and 0.9, respectively, showed aliasing artifacts, and its severities increased with pitches escalated (detector combination 16 x 1.5, reconstruction thickness 2 mm); There were more significant aliasing artifacts on the images reconstructed with 0.8 mm slice width compared with 1-mm slice width, and no aliasing artifacts were observed on the images reconstructed with 2-mm slice width (detector combination 16 x 0.75, pitch 0.6); No artifacts were perceived on the images scanned with detector combination 16 x 0.75, while presented evidently with the use of detector combination 16 x 1.5 (pitch 0.6, reconstruction thickness 2 mm); The degrees of aliasing artifacts were unaltered when reconstruction interval and tube current changed. Conclusions: Aliasing artifacts are caused by undersampling. When the operator choose the thinner sampling thickness, lower pitch and a much wider reconstruction thickness judiciously, aliasing artifacts could be effectively mitigated or suppressed. (authors)

  14. CT of tracheal agenesis

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Hernandez, Ramiro J.; Newman, Beverley

    2006-01-01

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  15. Coronary artery calcification detected by a mobile helical CT unit in a mass screening. The frequency and relationship to coronary risk factors and coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Itani, Yasutaka; Watanabe, Shigeru; Masuda, Yoshiaki [Chiba Univ. (Japan). School of Medicine; Hanamura, Kazuhisa; Asakura, Kazuhiro; Sone, Shusuke; Sunami, Yuko; Shimura, Akimitsu; Miyamoto, Tadaaki

    2001-06-01

    A strong relationship is known to exist between coronary artery disease (CAD) and coronary artery calcification (CAC) detected by CT. In this study, we investigated the frequency of CAC and the relationship between coronary risk factors, CAD and CAC in a mass screening using a mobile helical CT unit. The total number of participants was 10008 people undergoing a medical examination for lung cancer and tuberculosis using a mobile helical CT unit. We measured the CT density of the coronary artery to detect CAC. The CT density threshold for determining CAC was above +110HU. The frequency of CAC was 16.0% in the overall patient population and significantly higher in males than in females (20.6% vs 10.7%). Frequency increased with age in both genders. Hypertension and diabetes mellitus were significantly related to CAC. Smoking showed a correlation with CAC only in males. A significant relationship was observed between CAD and CAC in males. In particular, the relationship between them was strongest in males under 60 years of age. Furthermore, the odds ratio of CAC in predicting CAD increased with increasing risk factors in both genders. (author)

  16. Helical Face Gear Development Under the Enhanced Rotorcraft Drive System Program

    Science.gov (United States)

    Heath, Gregory F.; Slaughter, Stephen C.; Fisher, David J.; Lewicki, David G.; Fetty, Jason

    2011-01-01

    U.S. Army goals for the Enhanced Rotorcraft Drive System Program are to achieve a 40 percent increase in horsepower to weight ratio, a 15 dB reduction in drive system generated noise, 30 percent reduction in drive system operating, support, and acquisition cost, and 75 percent automatic detection of critical mechanical component failures. Boeing s technology transition goals are that the operational endurance level of the helical face gearing and related split-torque designs be validated to a TRL 6, and that analytical and manufacturing tools be validated. Helical face gear technology is being developed in this project to augment, and transition into, a Boeing AH-64 Block III split-torque face gear main transmission stage, to yield increased power density and reduced noise. To date, helical face gear grinding development on Northstar s new face gear grinding machine and pattern-development tests at the NASA Glenn/U.S. Army Research Laboratory have been completed and are described.

  17. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  18. Anterior glenoid rim fracture: the value of helical CT with threedimensional reconstruction and electronic humeral disarticulation

    Directory of Open Access Journals (Sweden)

    Heverton César de Oliveira

    2003-06-01

    Full Text Available Objectives: To show a new three-dimensional reconstructiontechnique based on helical computed tomography images withelectronic humeral disarticulation in anterior glenoid rim fractures,correlating the anatomic specimen with simulation of an anteriorglenoid rim fracture, as well as evaluating the extension of thefracture, the bone fragment position and distance in relation to theglenoid cavity in six patients. Methods: One scapula and onehumerus with no signs of fracture or congenital malformationswere placed in anatomical position using an adhesive tape aftersimulating an anterior glenoid rim fracture made by an osteotome.Helical CT imaging was acquired and three-dimensionalreconstructions were made based on these images, with andwithout electronic humeral disarticulation. The bone fragment waslocated, measured and its position in relation to the glenoid cavitywas assessed. Six patients with anterior glenoid rim fracture weresubmitted to CT of the shoulder using the same parameters asthose applied to the anatomic specimen. Results: In the anatomicspecimen and in all six patients the bone fragment was clearlydemonstrated; bone fragment measurements in the anatomicspecimen and in three-dimensional reconstructions wereequivalent. The fragment was better demonstrated in the imagestaken with electronic humeral disarticulation, particularly in thefrontal view of the glenoid cavity as observed in all six patients.Conclusion: We concluded that our experiment with the anatomicspecimen and the study of six patients allow us to state that thistechnique is safe and accurate to demonstrate the extension, sizeand location of the bone fragment in anterior glenoid rim fractures,and it provides essential elements for therapeutic planning.

  19. Imaging Features of Helical Computed Tomography Suggesting Advanced Urothelial Carcinoma Arising from the Pelvocalyceal System

    International Nuclear Information System (INIS)

    Kwak, Kyung Won; Park, Byung Kwan; Kim, Chan Kyo; Lee, Hyun Moo; Choi, Han Y ong

    2008-01-01

    Background: Urothelial carcinoma is the most common malignant tumor arising from the pelvocalyceal system. Helical computed tomography (CT) is probably the best preoperative-stage modality for the determination of treatment plan and prognosis. Purpose: To obtain helical CT imaging features suggesting advanced pelvocalyceal urothelial carcinoma. Material and Methods: Preoperative CT images in 44 patients with pelvocalyceal urothelial carcinoma were retrospectively reviewed and correlated with the pathological examination to determine imaging features suggesting stage III or IV of the disease. Results: Pathological stages revealed stage I in 16, stage II in three, stage III in 17, and stage IV in eight patients. Seven patients had metastatic lymph nodes. CT imaging showed that renal parenchymal invasion, sinus fat invasion, and lymph node metastasis were highly suggestive of advanced urothelial cell carcinoma (P<0.05). Helical CT sensitivity, specificity, and accuracy for advanced pelvocalyceal urothelial carcinoma were 76% (19/25), 84% (16/19), and 80% (35/44), respectively. Conclusion: Preoperative helical CT may suggest imaging features of advanced urothelial carcinoma, influencing treatment plan and patient prognosis, even though its accuracy is not so high

  20. Standardized CT examination of the multitraumatized patient

    Energy Technology Data Exchange (ETDEWEB)

    Leidner, B. [Department of Diagnostic Radiology, Oskarshamn Hospital (Sweden)]|[Department of Diagnostic Radiology, Huddinge University Hospital (Sweden); Adiels, M. [Department of Diagnostic Radiology, Oskarshamn Hospital (Sweden); Aspelin, P. [Department of Diagnostic Radiology, Huddinge University Hospital (Sweden); Gullstrand, P.; Wallen, S. [Department of Surgery, Oskarshamn Hospital (Sweden)

    1998-12-01

    The aim of this study was to develop a standardized non-helical-CT protocol including head, body and proximal extremities in order to achieve a good time efficiency and diagnostic accuracy in the initial radiological evaluation of the multitraumatized patient. A total of 111 circulatory stable blunt trauma patients, brought in to a trauma level II-III hospital, were examined according to a standardized CT protocol. After examining the head with contiguous 10-mm slices without IV contrast medium injection, the trunk was examined with 10-mm slices every 30 mm through thorax-abdomen-pelvis with IV contrast medium enhancement (occasionally modified). All data in the medical reports were collected and used as ``end-point``, and the outcome of the CT examination was compared with this final diagnosis. Mean examination time was 20 min (range 12-32 min). In total, 55 head injuries, 89 thoracic injuries, 27 abdominal/pelvic injuries and 62 fractures were found. Computed tomography correctly identified the injuries, except one brain stem injury, one contusion/rupture of the heart, one hepatic injury, two intestinal injuries, eight vertebral injuries and one joint dislocation. A standardized non-helical-CT examination of the head and body may be achieved in 20 min. Its diagnostic accuracy was high, except for vertebral column injuries, which is why we recommend it as the method of choice for initial radiological examination of multitraumatized patients. When available, helical scanning would improve both examination speed and accuracy. (orig.) With 6 figs., 40 refs.

  1. Conformal avoidance helical tomotherapy for dogs with nasopharyngeal tumors

    International Nuclear Information System (INIS)

    Welsh, J.S.; Turek, M.; Mackie, T.R.; Miller, P.; Mehta, M.P.; Forrest, L.J.

    2003-01-01

    Helical tomotherapy provides a unique means of delivering intensity-modulated radiation therapy (IMRT) using a novel treatment unit, which merges features of a linear accelerator with a helical CT scanner. Thanks to the CT imaging capacity, targeted regions can be visualized prior to, during, or immediately after each treatment. Such image-guidance through megavoltage CT will allow the realization and refinement of the concept of adaptive radiotherapy - the reconstruction of the actually delivered daily dose (as opposed to planned dose) accompanied by prescription adjustments when appropriate. In addition to this unique feature, helical tomotherapy promises further improvements in the specific avoidance of critical normal structures, i.e. conformal avoidance, the counterpart of conformal therapy. The first definitive treatment protocol using helical tomotherapy is presently underway for dogs with nasopharyngeal tumors. In general, such tumors can be treated with conventional external beam radiation therapy but at the cost of severe ocular toxicity due to the anatomy of the canine head. These are readily measurable toxicities and are almost universal in incidence; therefore, the canine nasopharyngeal tumor presents an ideal model to assess the ability to conformally avoid critical structures. It is hoped that conformal avoidance helical tomotherapy will improve tumor control via dose-escalation while reducing ocular toxicity in these veterinary patients. A total of 10 fractions are scheduled for these patients; the first 3 dogs have all received at least 7 fractions delivered via helical tomotherapy. Although preliminary, the first 3 dogs treated have not shown any evidence of ocular toxicity in this ongoing study

  2. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  4. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  5. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  6. Diffusion in a tokamak with helical magnetic cells

    International Nuclear Information System (INIS)

    Wakatani, Masahiro

    1975-05-01

    In a tokamak with helical magnetic cells produced by a resonant helical magnetic field, diffusion in the collisional regime is studied. The diffusion coefficient is greatly enhanced near the resonant surface even for a weak helical magnetic field. A theoretical model for disruptive instabilities based on the enhanced transport due to helical magnetic cells is discussed. This may explain experiments of the tokamak with resonant helical fields qualitatively. (author)

  7. Preliminary evaluation of helical CT colonography in detection of colonic diseases compared with double contrast barium enema

    International Nuclear Information System (INIS)

    Zhai Xiaoli; Zhang Lei; Zhai Renyou; Li Jie; Wang Yajie; Ding Yi

    2000-01-01

    Objective: To evaluate helical CT colonography in regard to technology principles, limitations, and clinical applications. Methods: Fifty-six patients underwent volume scanning using helical CT. The diseases included adenocarcinoma 39, adenomatous polyp 3, multiple diverticular 7, mucocele of appendix 1, and normal colon 6. All cases had been compared with double contrast barium enema (DCBE), proved by histology except the 6 normal colon and the 7 multiple diverticular. All CTC images were reconstructed using shaded surface display (SSD) on workstation. Then, perspective images such as the ones from DCBE were generated via ray sum. The images could clearly demonstrate the extent and detail of the disorder by using 'CUT' software, 'revolve' function, and zoom. Results: CTC correctly demonstrated 3-5 mm diverticulum, 3 mm ulcer, and 6 mm polyps. Not only show colon straitness clearly, CTC is also very sensitive to demonstrate the stenotic end of masses. In these cases, discovery rate of CTC is 100.0%, the rate of DCBE is 88.6%; CTC is more sensitive than DCBE in cases of tumor nodules. Ray sum can show the boundary of colonic mass extending to both proximal and distal ends, its discovery rate is 62.6%. Accuracy of localization for CTC is 100.0%. Conclusion: CTC is a novel technique for detecting colonic diseases. It is a safe, accurate, and non-invasive means for detection of lesions and is an efficient complement for DCBE. Further development in CTC technique is expected in the future

  8. Unenhanced helical CT in the evaluation of the urinary tract in children and young adults following urinary tract reconstruction: comparison with sonography

    Energy Technology Data Exchange (ETDEWEB)

    Myers, M.T.; Elder, J.S.; Sivit, C.J.; Applegate, K.E. [Dept. of Radiology, Rainbow Babies and Children' s Hospital, Cleveland, OH (United States)

    2001-03-01

    Purpose. To compare the accuracy of unenhanced, helical CT with sonography for the detection of complications of urinary tract reconstruction. Materials and methods. Forty-six kidneys in 24 patients were examined with CT and sonography. All scans were assessed for ease of renal visualization, presence of renal, ureteral, and bladder calculi, renal scars, hydronephrosis, and abdominal wall hernia. The results of both imaging modalities were independently reported. Results. CT provided excellent visualization of all 46 kidneys, while sonography provided poor visualization of 8 kidneys (17 %) (P < 0.001). CT detected calculi in 10 kidneys, 1 ureter, and 7 bladders. Sonography detected calculi in only 2 kidneys, and 2 bladders. Overall, CT detected significantly more calculi than US (18 vs 4, P = 0.01). CT detected scarring in 15 kidneys, while sonography detected scarring in 10. Hydronephrosis was detected in 6 kidneys by CT and in 8 kidneys by sonography. Three abdominal wall hernias were seen at CT that were not seen at sonography. Conclusion. CT is superior to sonography for the detection of urinary tract calculi and renal scarring. CT will demonstrate abdominal wall hernias that are unsuspected. (orig.)

  9. Enhanced transbuccal salmon calcitonin (sCT) delivery: effect of chemical enhancers and electrical assistance on in vitro sCT buccal permeation.

    Science.gov (United States)

    Oh, Dong-Ho; Chun, Kyeung-Hwa; Jeon, Sang-Ok; Kang, Jeong-Won; Lee, Sangkil

    2011-10-01

    This study investigates the combined effect of absorption enhancers and electrical assistance on transbuccal salmon calcitonin (sCT) delivery, using fresh swine buccal tissue. We placed 200 IU (40 μg/mL) of each sCT formulation--containing various concentrations of ethanol, N-acetyl-L-cysteine (NAC), and sodium deoxyglycocholate (SDGC)--onto the donor part of a Franz diffusion cell. Then, 0.5 mA/cm(2) of fixed anodal current was applied alone or combined with chemical enhancers. The amount of permeated sCT was analyzed using an ELISA kit, and biophysical changes of the buccal mucosa were investigated using FT-IR spectroscopy, and hematoxylin-eosin staining methods were used to evaluate histological alteration of the buccal tissues. The flux (J(s)) of sCT increased with the addition of absorption enhancer groups, but it was significantly enhanced by the application of anodal iontophoresis (ITP). FT-IR study revealed that all groups caused an increase in lipid fluidity but only the groups containing SDGC showed statistically significant difference. Although the histological data of SDGC groups showed a possibility for tissue damage, the present enhancing methods appear to be safe. In conclusion, the combination of absorption enhancers and electrical assistance is a potential strategy for the enhancement of transbuccal sCT delivery. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Myocardial delayed-enhancement CT: initial experience in children and young adults

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-10-15

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  11. Myocardial delayed-enhancement CT: initial experience in children and young adults

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2017-01-01

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  12. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  13. Enhanced Control for Local Helicity Injection on the Pegasus ST

    Science.gov (United States)

    Pierren, C.; Bongard, M. W.; Fonck, R. J.; Lewicki, B. T.; Perry, J. M.

    2017-10-01

    Local helicity injection (LHI) experiments on Pegasus rely upon programmable control of a 250 MVA modular power supply system that drives the electromagnets and helicity injection systems. Precise control of the central solenoid is critical to experimental campaigns that test the LHI Taylor relaxation limit and the coupling efficiency of LHI-produced plasmas to Ohmic current drive. Enhancement and expansion of the present control system is underway using field programmable gate array (FPGA) technology for digital logic and control, coupled to new 10 MHz optical-to-digital transceivers for semiconductor level device communication. The system accepts optical command signals from existing analog feedback controllers, transmits them to multiple devices in parallel H-bridges, and aggregates their status signals for fault detection. Present device-level multiplexing/de-multiplexing and protection logic is extended to include bridge-level protections with the FPGA. An input command filter protects against erroneous and/or spurious noise generated commands that could otherwise cause device failures. Fault registration and response times with the FPGA system are 25 ns. Initial system testing indicates an increased immunity to power supply induced noise, enabling plasma operations at higher working capacitor bank voltage. This can increase the applied helicity injection drive voltage, enable longer pulse lengths and improve Ohmic loop voltage control. Work supported by US DOE Grant DE-FG02-96ER54375.

  14. Mediastinal fibrosis with pulmonary artery obstruction; diagnosis and investigation with helical CT imaging including 3-dimensional reconstructions; Pulomonalarterienstenose bei aggresiver Mediastinalfibrose; Diagnostik und 3D-Darstellung mittels helikaler CT-Untersuchung

    Energy Technology Data Exchange (ETDEWEB)

    Kolbe, M. [Inst. fuer Diagnostische Radiologie, Kantonsspital Basel (Switzerland); Helwig, A. [Inst. fuer Diagnostische Radiologie, Kantonsspital Basel (Switzerland); Habicht, J.M. [Klinik fuer Herz-Torax-Chirurgie, Universitaetskliniken Basel (Switzerland); Steinbruch, W. [Inst. fuer Diagnostische Radiologie, Kantonsspital Basel (Switzerland)

    1997-07-01

    An aggressive mediastinal fibrosis was found in a 42-year-old female, suffering from dysphagia, stabbing pain in the chest, and an unclear weight loss. In this case, the rare combination of esophageal involvement, bronchial narrowing, and pulmonary artery obstruction could easily be demonstrated with a barium study and a helical CT examination including three-dimensional reconstructions. (orig.) [Deutsch] Wir stellen den Fall einer 42jaehrigen Patientin vor, welche zur Abklaerung einer zunehmenden Dysphagie, stechender Thoraxschmerzen und eines Gewichtsverlustes hospitalisiert wurde. Mittels klinischer und radiologischer Abklaerung konnte eine aggressive Mediastinalfibrose diagnostiziert werden. Die seltene Kombination einer Oesophaguseinengung mit Pulmonalarterienstenosen sowie einer Bronchuskompression konnte nichtinvasiv mittels Oesophagogramm und helikaler CT-Untersuchung zuverlaessig und schnell dargestellt werden. (orig.)

  15. Intraductal papillary mucinous neoplasms of the pancreas: Correlation of helical CT features with pathologic findings

    International Nuclear Information System (INIS)

    Liu Yu; Lin Xiaozhu; Upadhyaya, Manavendra; Song Qi; Chen Kemin

    2010-01-01

    Objective: To evaluate the CT features of intraductal papillary mucinous neoplasms of the pancreas (IPMNs), and to compare with pathological findings in order to identify CT features that can be helpful in differentiating benign IPMNs from malignant IPMNs. Materials and methods: The CT findings in 25 patients were reviewed for tumor location, tumor type, dilatation of the main pancreatic duct (MPD), MPD involvement, mural node or solid attenuating component, tumor size in branch duct or mixed duct type, dilatation of common bile duct (CBD) and invasion of surrounding structures. The data was subjected to Chi-Square Tests or Fisher's Exact Test using SPSS13.0 software with p value < 0.05 indicating significant statistical difference. Results: Presence of mural node or solid enhancing component, size of mural node or solid enhancing component ≥7 mm, dilatation of CBD was more common in malignant IPMNs (p < 0.05). None of tumor location, tumor type, dilatation of MPD, MPD involvement, tumor size, and invasion of surrounding structures was statistically significant in differentiating benign from malignant IPMNs. Conclusions: CT features suggestive of malignant or invasive IPMNs include presence of mural node or solid enhancing component, size of mural node or solid enhancing component ≥7 mm, and dilatation of CBD.

  16. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  17. Usefulness of percentage enhancement washout value calculated on unenhanced, contrast-enhanced, and delayed enhanced CT in adrenal masses: adenoma versus metastasis

    International Nuclear Information System (INIS)

    Sohn, Kyung Myung; Lee, Sung Yong; Lee, Keun Ho

    2003-01-01

    To determine the usefulness of percentage enhancement washout value calculated on unenhanced, enhanced and delayed enhanced CT scans for the characterization of adrenal masses. Forty adrenal masses less than 5 cm in size were assessed using a protocol consisting of unenhanced CT, enhanced CT 60 seconds after intravenous administration of contrast material, and delayed enhanced CT at 10 minutes. The CT attenuation value of adrenal tumors was estimated on each scan, and percentage enhancement washout value was calculated as follows:[(attenuation value at enhanced CT-attenuation value at delayed CT)/ (attenuation value at enhanced CT-attenuation value at unenhanced CT)x100]. An adrenal mass was considered benign if its percentage enhancement washout value was at the threshold value, set to 60% and 50%, or higher. The accuracy of the procedure was determined by comparing its findings with the final clinical diagnosis. Twenty-nine massess were benign and 11 were malignant. The mean percentage enhancement washout value of the former was significantly higher than that of the latter (66.7% vs. 21.8%; p<0.01). All adenomas except one had a washout value of more than 50%. With a percentage washout threshold of 60%, 35 of 40 lesions were correctly characterized as benign or malignant [sensitivity 82.7% (24/29), specificity 100% (11/11), accuracy 87.5% (35/40)]; with a threshold of 50%, 39 of 40 lesions were correctly characterized [(sensitivity 96.5% (28/29), specificity 100% (11/11), accuracy 97.5% (39/40)]. Percentage enhancement washout values are useful for characterizing an adrenal mass as benign or malignant. For characterization, a threshold value of 50% was more accurate than one of 60%

  18. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  19. The utility of helical CT in assessing the frequency of ureterolithiasis in Saudi patients

    International Nuclear Information System (INIS)

    Al-Nakshabandi, Nizar A.; Zayed, Mohamed A.; Elsharkaway, Mohamed S.; Al-Boukai, Ahmad S.; Al-Omar, M.

    2008-01-01

    Objective was to identify 650 patients who underwent Ct for renal colic and review them for age and gender in Saudi Arabia. Scans were performed on a 16 multislice scanner. A total of 650 patients with the clinical suspicion of ureteric colic were reviewed; 220 females (33.8%) and 430 males (66.2%), with a female to male ratio of 1:2. Examinations were carried out from January 2005 to November 2006, at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia. Three hundred and ninety five patients out of 650 had stones; 2 of 395 (0.5%) had stones in the 5-15 years age group, 28 (7.%) in the 16-25 years age group, 99 (25.1%) in the 26-35 years, 106 (26.8%) in the 36-45 age group, 84 (21.9%) in the 46-55 age group, 51 (12.9%) in the 56-65 age group, and 25 (6.3%) in the above 66 years age group. The most significant finding in our study is that as the patients age increases so does the percentage of stones up to the age of 56, with a peak at age group of 26-35 where stone percentage reaches 26.8%. Unenhanced helical CT is useful for the diagnosis of ureterolithiasis. (author)

  20. Dual-phase helical CT using bolus triggering technique: optimization of transition time

    International Nuclear Information System (INIS)

    Choi, Young Ho; Kim, Tae Kyoung; Park, Byung Kwan; Koh, Young Hwan; Han, Joon Koo; Choi, Byung Ihn

    1999-01-01

    To optimize the transition time between the triggering point in monitoring scanning and the initiation of diagnostic hepatic arterial phase (HAP) scanning in hepatic spiral CT, using a bolus triggering technique. One hundred consecutive patients with focal hepatic lesion were included in this study. Patients were randomized into two groups. Transition times of 7 and 11 seconds were used in group 1 and 2, respectively. In all patients, bolus triggered HAP spiral CT was obtained using a semi-automatic bolus tracking program after the injection of 120mL of non-ionic contrast media at a rate of 3mL/sec. When aortic enhancement reached 90 HU, diagnostic HAP scanning began after a given transition time. From images of group 1 and group 2, the degree of parenchymal enhancement of the liver and tumor-to-liver attenuation difference were measured. Also, for qualitative analysis, conspicuity of the hepatic artery and hypervascular tumor was scored and analyzed. Hepatic parenchymal enhancement on HAP was 12.07 + /-6.44 HU in group 1 and 16.03 + /-5.80 HU in group 2 (p .05). In the evaluation of conspicuity of hepatic artery, there was no statistically significant difference between the two groups (p > .05). The conspicuity of hypervascular tumors in group 2 was higher than in group 1 (p < .05). HAP spiral CT using a bolus triggering technique with a transition time of 11 seconds provides better HAP images than when the transition time is 7 seconds

  1. A clinical study concerning hepatic arterial dominant phase and arrival time of contrast media on helical dynamic CT

    International Nuclear Information System (INIS)

    Matsubara, Susumu; Uchida, Chiharu; Sato, Sei; Ishida, Junichi; Masuya, Ryozo; Makiguchi, Mako; Kanamori, Isao

    2001-01-01

    Hepatic arterial dominant phase in helical dynamic CT was optimized by measuring the arrival time of contrast media (ATCM) with time-density curve (TDC). Subjects were 1005 patients (577 males and 428 females) and 98 nodules diagnosed as advanced hepatocellular carcinoma (HCC). The CT was done with Toshiba 4MHU X-vision SP, ultrasonography with Toshiba SSH-160A and automatic infusion of the contrast medium, iopamidol or iohexol, with Nemotokyorindo Autoenhance A-50. ATCM was found correlated with pulse rate and with arterial diameter, and significantly different between the sex. Elevation slope of TDC was suggested to be made constant by a defined infusion time of the dose corrected by body weight. Fluctuation of TDC among patients , when normalized by ATCM, was found smaller and the TDC was suggested to be useful for better imaging of HCC of less than 10 mm diameter. (K.H.)

  2. CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shunsuke; Yamada, Yoshitake; Hashimoto, Masahiro; Okamura, Teppei; Jinzaki, Masahiro [Keio University School of Medicine, Department of Diagnostic Radiology, Shinanomachi, Shinjuku-ku, Tokyo (Japan); Yamada, Minoru [Keio University School of Medicine, Research Park, Tokyo (Japan); Yashima, Fumiaki; Hayashida, Kentaro; Fukuda, Keiichi [Keio University School of Medicine, Department of Cardiology, Tokyo (Japan)

    2017-05-15

    To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD). Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time x weight [kg] x 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard. The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV). CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD. (orig.)

  3. Sepsis patients' renal manifestation on contrast-enhanced CT

    International Nuclear Information System (INIS)

    Sasaguri, K.; Yamaguchi, K.; Nakazono, T.; Mizuguchi, M.; Irie, H.

    2016-01-01

    Aim: To evaluate renal volume and attenuation changes in patients with sepsis on contrast-enhanced computed tomography (CT) with respect to the severity of sepsis. Materials and methods: Forty-four patients with sepsis who underwent CT before and after the onset of sepsis were retrospectively analysed. Renal volume and CT attenuation value of the renal cortex on contrast-enhanced CT were measured for each patient and changes in renal volume and CT attenuation value from before to after the onset of sepsis were calculated. The changes were correlated with the severity of sepsis (Sepsis-related Organ Failure Assessment [SOFA] score). The time course of the renal volume and CT attenuation changes were also evaluated. Results: Renal volume increased by 17.6% and CT attenuation value decreased by 19% after the onset of sepsis with statistically significant differences (p<0.001 for both renal volume and CT attenuation changes). The renal volume and CT attenuation changes had significant correlations with the SOFA score (r=0.36, p=0.018 and −0.43, p=0.005, respectively). The time course of the renal volume and CT attenuation changes seemed to be gradual compared to that of the SOFA score and to lag behind the peak of the SOFA score. Conclusion: In patients with sepsis, the renal volume increases and the CT attenuation value decreases in proportion to the severity of sepsis. The changes may lag behind the peak of severity of sepsis and can be observed for a relatively long time after a patient's recovery from sepsis. - Highlights: • The renal volume increases and the renal enhancement on contrast-enhanced CT decreases in patients with sepsis. • The degrees of these changes are correlated with severity of sepsis. • These changes may lag behind the peak of severity of sepsis and last for a long time after a patient's recovery from sepsis.

  4. {sup 18}F-FDG PET/CT imaging versus dynamic contrast-enhanced CT for staging and prognosis of inflammatory breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Champion, Laurence; Edeline, Veronique; Giraudet, Anne-Laure; Wartski, Myriam [Service de Medecine Nucleaire, Saint-Cloud (France); Lerebours, Florence [Service d' Oncologie Medicale, Saint-Cloud (France); Cherel, Pascal [Institut Curie, Hopital Rene Huguenin, Service de Radiologie, Saint-Cloud (France); Bellet, Dominique [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Paris Descartes, Pharmacologie Chimique et Genetique and Imagerie, Inserm U1022 CNRS UMR 8151, Faculte des sciences pharmaceutiques et biologiques, Paris (France); Alberini, Jean-Louis [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Versailles Saint-Quentin, Faculte de medecine, Saint-Quentin-en-Yvelines (France)

    2013-08-15

    Inflammatory breast cancer (IBC) is the most aggressive type of breast cancer with a poor prognosis. Locoregional staging is based on dynamic contrast-enhanced (DCE) CT or MRI. The aim of this study was to compare the performances of FDG PET/CT and DCE CT in locoregional staging of IBC and to assess their respective prognostic values. The study group comprised 50 women (median age: 51 {+-} 11 years) followed in our institution for IBC who underwent FDG PET/CT and DCE CT scans (median interval 5 {+-} 9 days). CT enhancement parameters were net maximal enhancement, net early enhancement and perfusion. The PET/CT scans showed intense FDG uptake in all primary tumours. Concordance rate between PET/CT and DCE CT for breast tumour localization was 92 %. No significant correlation was found between SUVmax and CT enhancement parameters in primary tumours (p > 0.6). PET/CT and DCE CT results were poorly correlated for skin infiltration (kappa = 0.19). Ipsilateral foci of increased axillary FDG uptake were found in 47 patients (median SUV: 7.9 {+-} 5.4), whereas enlarged axillary lymph nodes were observed on DCE CT in 43 patients. Results for axillary node involvement were fairly well correlated (kappa = 0.55). Nineteen patients (38 %) were found to be metastatic on PET/CT scan with a significant shorter progression-free survival than patients without distant lesions (p = 0.01). In the primary tumour, no statistically significant difference was observed between high and moderate tumour FDG uptake on survival, using an SUVmax cut-off of 5 (p = 0.7 and 0.9), or between high and low tumour enhancement on DCE CT (p > 0.8). FDG PET/CT imaging provided additional information concerning locoregional involvement to that provided by DCE CT on and allowed detection of distant metastases in the same whole-body procedure. Tumour FDG uptake or CT enhancement parameters were not correlated and were not found to have any prognostic value. (orig.)

  5. Is contrast-enhanced CT indicated in acute head injury

    International Nuclear Information System (INIS)

    Mauser, H.W.; Nieuwenhuizen, O. van; Veiga-Pires, J.A.

    1984-01-01

    The authors discuss the value of intravenous contrast enhancement in CT scanning in acute head injury. In a series of seventy consecutive patients they conclude that no incremental information was obtained by performing contrast-enhanced CT scans in the acute phase of the head injury. (orig.)

  6. Intra-arterial CT-angiography for cerebral arteriovenous malformation--initial experiences for treatment planning of radiosurgery

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Kawaguchi, Osamu; Onozuka, Satoshi; Momoshima, Suketaka; Takeda, Atsuya; Shigematsu, Naoyuki; Hashimoto, Subaru; Ohira, Takayuki; Kubo, Atsushi

    2002-01-01

    Purpose: To clarify the feasibility and effectiveness of intra-arterial CT angiography (IACTA) for treatment planning of arteriovenous malformation radiosurgery. Methods and Materials: A CT scanner installed in an angiographic examination room was used. Helical IACTA was performed in 22 patients during continuous intra-arterial infusion of contrast medium via the internal carotid or vertebral artery, and dynamic IACTA was performed in 20 of these patients with reconstruction at 0.2-s intervals. The dynamic IACTA was repeated for each 3- or 5-mm increment to encompass the nidus. Subtractions were performed in postembolization cases. A retrospective review of IACTA was performed to assess the effectiveness of dynamic scans. Results: No complications related to the angiographic procedure or CT imaging were detected. High contrast enhancement was obtained for both helical and dynamic IACTA. In 18 of the 20 cases (90%), draining veins were separated from the nidus by using the enhancement patterns, and in 13 cases (65%), feeding arteries were separated. Conclusion: Dynamic IACTA added important information for target-volume determinations. Conventional CT and MRI could be omitted from the protocol, and the period that patients wore the frame was substantially shortened. We conclude that IACTA is a practical and useful method for radiosurgical treatment planning of arteriovenous malformations

  7. CT findings in autoimmune pancreatitis: assessment using multiphase contrast-enhanced multisection CT

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K., E-mail: Kojiro@med.nagoya-u.ac.j [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Nagoya Hirokoji Clinic, Nagoya (Japan); Nagasaka, T. [Departments of Medical Technology, Nagoya University School of Health Science, Nagoya (Japan); Ogawa, H.; Ota, T.; Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2010-09-15

    Aim: To assess the spectrum of findings using multiphase contrast-enhanced computed tomography (CT) in patients with autoimmune pancreatitis (AIP). Materials and methods: Fifty patients (four female and 46 male, mean age 65 years) were retrospectively identified from consecutive patients with abnormal CT findings of the pancreas and negative work-up for known causes. These patients had at least one finding supporting the diagnosis of AIP: serological abnormality, histopathological abnormality, or response to steroid. Two radiologists evaluated multiphase contrast-enhanced CT images in consensus. Results: The pancreas showed diffuse enlargement (n = 16; 32%), focal enlargement (n = 18; 36%), or no enlargement (n = 16; 32%). Forty-nine (98%) patients showed abnormal contrast enhancement in the affected pancreatic parenchyma, including hypoattenuation during the pancreatic phase (n = 45; 90%) and hyperattenuation during the delayed phase (n = 39; 87%). The following findings were also seen in the pancreas: a capsule-like rim (n = 24; 48%); no visualization of the main pancreatic duct lumen (n = 48; 96%); ductal enhancement (n = 26; 52%); upstream dilatation of the main pancreatic duct (n = 27; 54%); upstream atrophy of the pancreatic parenchyma (n = 27; 54%); calcification (n = 7; 14%); and cysts (n = 5; 10%). Forty-two (84%) patients showed one or more of the following extrapancreatic findings: biliary duct or gallbladder abnormality (n = 40; 80%); peripancreatic (n = 8; 16%) or para-aortic (n = 10; 20%) soft-tissue proliferation; and renal involvement (n = 15; 30%). Conclusion: Patients with AIP presented with a variety of CT findings in the pancreas and the extrapancreatic organs. The present study highlights pancreatic ductal enhancement in a subset of patients with AIP.

  8. Respiratory gated lung CT using 320-row area detector CT

    International Nuclear Information System (INIS)

    Sakamoto, Ryo; Noma, Satoshi; Higashino, Takanori

    2010-01-01

    Three hundred and twenty-row Area Detector CT (ADCT) has made it possible to scan whole lung field with prospective respiratory gated wide volume scan. We evaluated whether the respiratory gated wide volume scan enables to reduce motion induced artifacts in the lung area. Helical scan and respiratory gated wide volume scan were performed in 5 patients and 10 healthy volunteers under spontaneous breathing. Significant reduction of motion artifact and superior image quality were obtained in respiratory gated scan in comparison with helical scan. Respiratory gated wide volume scan is an unique method using ADCT, and is able to reduce motion artifacts in lung CT scans of patients unable to suspend respiration in clinical scenes. (author)

  9. Ultrasound-guided radiofrequency thermal ablation of normal kidney in a rabbit model: correlation with CT and histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Lee, Jeong Min; Kin, Chong Soo; Lee, Sang Hun [College of Medicine, Chonbuk National Univ., Chonju (Korea, Republic of)

    2002-01-01

    To assess the feasibility and safety of using a cooled-tip electrode to perform percutaneous radiofrequency ablation of kidney tissue in rabbits, and to evaluate the ability of CT to reveal the appearance and extent of tissue necrosis during follow-up after ablation. Using ultrasound guidance, a 17-G cooled-tip electrode was inserted into the right lower portion of the kidney in 26 New Zealand White rabbits. Radiofrequency was applied for 2 mins, and biphasic helical CT scanning was used to assess tissue destruction and the presence or absence of complications immediately after the procedure and at 24 hrs, 2 and 3 days, and 1,2,3,4,5,6 and 7 weeks. The study had three phases: acute (immediately killed : N=10); subacute (killed at 24 hrs (n=3), 2 days (n=3), 3 days (n=1) : N=7); chronic (killed at 1 week (n=4), 2 weeks (n=2), 4 weeks (n=1), 7 weeks (n=1): N=8). After the animals were killed, their kidneys were histopathologically examined and the radiologic and pathologic findings of lesion size and configuration were correlated. In each instance, ultrasound-guided radiofrequency ablations of the lower pole of the kidney were technically successful. Contrast-enhanced biphasic helical CT revealed regions of hypoattenuation devoid of parenchymal enhancement, and these correlated closely with true pathologic lesion size (r=0.884; p>0.05). In subacute and chronic models, CT scanning revealed gradual spontaneous resorption of the ablated lesion and the presence of perilesional calcification. Histopathologically, in the acute phase the ablated lesion showed coagulative necrosis and infiltration of inflammatory cells, and in the chronic phase there was clear cut necrosis of glomeruli, tubules and renal interstitium, with diminishing inflammatory response and peripheral fibrotic tissue formation. Ultrasound-guided renal radiofrequency ablation is technically feasible and safe. In addition, the avascular lesion measured at contrast-enhanced helical CT closely correlated with

  10. Ultrasound-guided radiofrequency thermal ablation of normal kidney in a rabbit model: correlation with CT and histopathology

    International Nuclear Information System (INIS)

    Kim, Sang Won; Lee, Jeong Min; Kin, Chong Soo; Lee, Sang Hun

    2002-01-01

    To assess the feasibility and safety of using a cooled-tip electrode to perform percutaneous radiofrequency ablation of kidney tissue in rabbits, and to evaluate the ability of CT to reveal the appearance and extent of tissue necrosis during follow-up after ablation. Using ultrasound guidance, a 17-G cooled-tip electrode was inserted into the right lower portion of the kidney in 26 New Zealand White rabbits. Radiofrequency was applied for 2 mins, and biphasic helical CT scanning was used to assess tissue destruction and the presence or absence of complications immediately after the procedure and at 24 hrs, 2 and 3 days, and 1,2,3,4,5,6 and 7 weeks. The study had three phases: acute (immediately killed : N=10); subacute (killed at 24 hrs (n=3), 2 days (n=3), 3 days (n=1) : N=7); chronic (killed at 1 week (n=4), 2 weeks (n=2), 4 weeks (n=1), 7 weeks (n=1): N=8). After the animals were killed, their kidneys were histopathologically examined and the radiologic and pathologic findings of lesion size and configuration were correlated. In each instance, ultrasound-guided radiofrequency ablations of the lower pole of the kidney were technically successful. Contrast-enhanced biphasic helical CT revealed regions of hypoattenuation devoid of parenchymal enhancement, and these correlated closely with true pathologic lesion size (r=0.884; p>0.05). In subacute and chronic models, CT scanning revealed gradual spontaneous resorption of the ablated lesion and the presence of perilesional calcification. Histopathologically, in the acute phase the ablated lesion showed coagulative necrosis and infiltration of inflammatory cells, and in the chronic phase there was clear cut necrosis of glomeruli, tubules and renal interstitium, with diminishing inflammatory response and peripheral fibrotic tissue formation. Ultrasound-guided renal radiofrequency ablation is technically feasible and safe. In addition, the avascular lesion measured at contrast-enhanced helical CT closely correlated with

  11. The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging. Implications for CT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perisinakis, Kostas; Damilakis, John [University of Crete, Department of Medical Physics, Medical School, Heraklion, Crete (Greece); University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Tzedakis, Antonis; Papadakis, Antonios E. [University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Spanakis, Kostas [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); Hatzidakis, Adam [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); University of Crete, Department of Radiology, Medical School, Heraklion, Crete (Greece)

    2018-01-15

    To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry. The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging. The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake. Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure. (orig.)

  12. Enhanced dual-phase spiral CT features of polypoid ampullary carcinoma

    International Nuclear Information System (INIS)

    Zeng Mengsu; Yan Fuhua; Zhou Kangrong; Chen Huiming; Chen Gang; Chen Jin

    2001-01-01

    Objective: To understand CT features of polypoid ampullary carcinoma by enhanced dual-phase spiral CT. Methods: 15 cases of polypoid ampullary carcinoma (PAC) confirmed by surgical and pathological results were studied with thin slice enhanced dual-phase spiral CT (including arterial and portal phase scanning)with retrospective analysis, the scanning parameters were 5 mm thickness and 1.0 pitch for arterial phase scanning, and 5 mm thickness and 5 mm space for portal phase scanning. Results: All cases could display an enhanced mass as local filling defect at the site of the duodenal Vater's ampulla during arterial and portal phase scanning, the tumors ranged in size from 1 cm to 5 cm with mean of 2.3 cm, all were accompanied with dilated intrahepatic and common bile duct, enlarged gallbladder and dilated pancreatic duct, except one case which had marked atrophy of the pancreatic body and tail. Conclusion: The thin slices enhanced dual-phase spiral CT could not only accurately define the level of obstruction, but also demonstrate an enhanced mass as direct CT sign of the PAC, which is crucial for diagnosis of the PAC

  13. Evaluation of delayed contrast-enhanced CT scan in diagnosing hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Jianding; Liang Chenyang; Zhang Hua; Zhang Yuezhen; Li Rui

    2001-01-01

    Objective: To assess the diagnostic value of delayed CT contrast enhancement patterns in hilar cholangiocarcinoma based on two-phased dynamic incremental CT scanning. Methods: Fifty-two patients with suspected hilar tumor and bile duct obstruction underwent spiral CT scan. The scan time for one revolution of the X-ray tube was 1 second. To elucidate the delay time for optimal imaging, all proved cholangiocarcinoma with delayed (6, 8, 10, 15, 20, 30 minutes) post-equilibrium-phase contrast-enhanced CT scans were acquired with unenhanced, dynamic contrast-enhanced, and delayed images. Degree of delayed enhancement was compared with that of surrounding liver parenchyma. Results: (1) 8-15 minutes after IV injection of contrast material was the delay time for optimal imaging. (2) Of 29 cholangiocarcinomas, the early CT showed hypo-attenuating (lower than that of liver parenchyma) in 23 tumors, iso-attenuating (equal to that of the liver) in 4 tumors, and hyper-attenuating (higher than that of liver) in 2 tumors. The delayed CT scan showed iso-attenuating in 8 tumors, hyper-attenuating in 21 tumors, and no hypo-attenuating. Most of delay imaging of hilar cholangiocarcinoma may appear hyper-attenuating (U = -4.3073, P 2 = 9.09, P < 0.01). Conclusion: When assessing hilar tumor, delayed CT contrast enhancement patterns based on two-phase dynamic incremental CT scans is useful in the detection and characterization of hilar cholangiocarcinoma

  14. Late Adverse Events after Enhanced and Unenhanced MRI and CT

    DEFF Research Database (Denmark)

    Azzouz, Manal; Rømsing, Janne; Thomsen, Henrik S.

    2014-01-01

    Prospective evaluation of frequency of late and very late adverse events in patients undergoing enhanced or unenhanced magnetic resonance imaging (MRI) or computed tomography (CT). The imaging procedure was performed according to the protocols of the department. All patients were contacted three...... of LAEs was significantly higher in the enhanced MRI (38%) and CT (27%) groups than unenhanced MRI (20%) and CT (16%) groups. The frequency of nausea, dizziness, abdominal pain and diarrhoea was significantly higher in the enhanced MRI group than in the MRI control group, while taste sensation...

  15. Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ho Gul; Kim, Kee Deog; Park, Hyok; Kim, Dong Ook; Jeong, Hai Jo; Kim, Hee Joung; Yoo, Sun Kook; Kim, Yong Oock; Park, Chang Seo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate the quantitative accuracy of three-dimensional (3D) images by mean of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0 (Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. 11 line items in Conventional 3 mm, 8 in Helical 3 mm, 11 in Conventional 5 mm, 10 in Helical 5 mm, 5 in Conventional 7 mm and 9 in Helical 7 mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2 mm in 19 line items of Conventional 3 mm. 20 of Helical 3 mm, 15 of Conventional 5 mm, 18 of Helical 5 mm, 11 of Conventional 7 mm and 16 of Helical 7 mm. Considering image quality and patient's exposure time, scanning protocol of Helical 5 mm is recommended for 3D image analysis of the skull in CT.

  16. Study of Pelvicaliceal Anatomy by Helical Computerized Tomography

    International Nuclear Information System (INIS)

    Al-Qahtani, Fahd N.; Ali, Gaber A.; Kamal, Baher A.; Taha, Saud A.

    2003-01-01

    To evaluate the role of 3-dimensional images produced by computerized tomography (CT), using intravenous contrast, to study pelvicaliceal anatomy.This might be of help in endourological procedure. The study was conducted in the King Fahd Hospital of the University, King Faisal University. Dammam,Kingdom of Saudi Arabia. The study took place from July 2002 through to October 2002 .Helical CT was carried for patients who were investigated using excretory urography for any reason. A CT was carried out to the kidneys only within 10 minutes ( between 5 and 15 minute films of excretory urography).Images were reprocessed by 3-dimension construction after subtracting all structures except for the palvicaliceal system. Thity-six normal kidneys were studied. The upper pole was drained by a single caliceal infundibulum in all 36(100%) kidneys.the middle segement of the kidney was drained by 2 infundibula in 32 (89%) kidneys. Four (11%) kidneys have no middle caliceal infudibula. The lower pole was drained by 2 caliceal infundibula in 23 (64%) and a single infundibulum in 13 (36%) kidneys. The minor calices draining each renal segment were seen clearly. Three-dimensional images derived by helical CT are feasible for evaluating the anatomy of palvicaliceal system,and, can be of help in endourological procedures. (author)/

  17. Volume doubling time and growth rate of renal cell carcinoma determined by helical CT: a single-institution experience

    International Nuclear Information System (INIS)

    Lee, Ji Young; Kim, Chan Kyo; Choi, Dongil; Park, Byung Kwan

    2008-01-01

    The purpose of this study was to retrospectively evaluate the volume doubling time (VDT) and growth rate of renal cell carcinomas (RCC) on a serial computed tomography (CT) scan. Thirty pathologically proven RCCs were reviewed with helical CT. Each tumor underwent at least two CT scans. Tumor volume was determined using an area measuring tool and the summation-of-areas technique. Growth rate was evaluated in terms of diameter and volume changes. VDT and volume growth rate were compared in relation to several factors (initial diameter, initial volume, diameter growth rate, volume growth rate, tumor grade, tumor subtype, sex or age). Mean VDT of RCCs was 505 days. Mean diameter and volume growth rate were 0.59 cm/year and 19.1 cm 3 /year, respectively. For volume and diameter growth rate, tumors ≤4 cm showed lower rates than those >4 cm (P 0.05). Volume growth rate was moderately to strongly positively correlated with initial diameter, initial volume and diameter growth rate (P < 0.05). In conclusion, small RCCs grew at a slow rate both diametrically and volumetrically. More accurate assessment of tumor growth rate and VDT may be helpful to understand the natural history of RCC. (orig.)

  18. Fourier-based approach to interpolation in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2001-01-01

    It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal direction and because the exploitation of the redundancy of fanbeam data acquired over 360 degree sign to generate additional longitudinal samples does not automatically eliminate the aliasing. In this paper we demonstrate that for pitches near 1 or lower, the redundant fanbeam data, when used properly, can provide sufficient information to satisfy a generalized sampling theorem and thus to eliminate aliasing. We develop and evaluate a Fourier-based algorithm, called 180FT, that accomplishes this. As background we present a second Fourier-based approach, called 360FT, that makes use only of the directly measured data. Both Fourier-based approaches exploit the fast Fourier transform and the Fourier shift theorem to generate from the helical projection data a set of fanbeam sinograms corresponding to equispaced transverse slices. Slice-by-slice reconstruction is then performed by use of two-dimensional fanbeam algorithms. The proposed approaches are compared to their counterparts based on the use of linear interpolation - the 360LI and 180LI approaches. The aliasing suppression property of the 180FT approach is a clear advantage of the approach and represents a step toward the desirable goal of achieving uniform longitudinal resolution properties in reconstructed helical CT volumes

  19. Enhancement pattern of small hepatic hemangioma: findings on multiphase spiral CT and dynamic MRI

    International Nuclear Information System (INIS)

    Choi, Byung In; Lee, Seung Koo; Kim, Myeong Jin; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To compare the enhancement characteristics of small hemangiomas seen on multiphase spiral CT and dynamic MR imaging. Thirteen patients with 20 hepatic hemangiomas less than 25mm in diameter underwent both multiphase spiral CT and dynamic MR imaging. All lesions were assigned to one of three classified into 3 categories according to the enhancement pattern seen on multiphase spiral CT : typical delayed pooling, atypical early enhancement, or continuous low attenuation. The enhancement patterns seen on spiral CT and on dynamic MRI were correlated. On CT scans, ten lesions (50%) showed delayed pooling. Six (30%) showed early arterial enhancement and four (20%) showed continuous low attenuation. On delayed-phase MRI, all lesions showed delayed high signal intensity compared to adjacent liver parenchyma. Four of six lesions with early enhancement on CT showed peripheral globular enhancement on early arterial-phase MRI. On multiphase spiral CT scans, small hemangiomas can show variable atypical enhancement features. In this situation, contrast-enhanced dynamic MRI is helpful for the diagnosis of hemangiomas

  20. Chronic intestinal pseudo-obstruction in adult patients: multidetector row helical CT features

    International Nuclear Information System (INIS)

    Merlin, Aurelie; Soyer, Philippe; Boudiaf, Mourad; Hamzi, Lounis; Rymer, Roland

    2008-01-01

    Chronic intestinal pseudo-obstruction (CIPO) is a rare condition due to severe gastrointestinal motility disorder. Adult patients with CIPO experience symptoms of mechanical obstruction, but reliable clinical signs that may help distinguish between actual mechanical obstruction and CIPO are lacking. Additionally, abdominal plain films that commonly show bowel dilatation with air-fluid levels do not reach acceptable degrees of specificity to exclude actual obstruction. Therefore, most adult patients with CIPO usually undergo multiple and often fruitless surgery, often leading to repeated bowel resections before diagnosis is made. In these patients who present with abdominal signs mimicking symptoms that would warrant surgical exploration, multidetector-row helical CT (MDCT) is helpful to resolve this diagnostic dilemma. MDCT shows a diffusely distended bowel and helps to rule out a mechanical cause of obstruction, thus suggesting CIPO and obviating the need for unnecessary laparotomy. In adult patients with CIPO, MDCT may show pneumatosis intestinalis, pneumoperitoneum or intussusception. However, these conditions generally do not require surgery in patients with CIPO. This pictorial essay presents the more and less common MDCT features of CIPO in adult patients, to make the reader more familiar with this disease. (orig.)

  1. PET/CT in malignant melanoma: contrast-enhanced CT versus plain low-dose CT

    International Nuclear Information System (INIS)

    Pfluger, Thomas; Schneider, Vera; Fougere, Christian la; Bartenstein, Peter; Weiss, Mayo; Melzer, Henriette Ingrid; Coppenrath, Eva; Berking, Carola

    2011-01-01

    The aim of this study was to evaluate the diagnostic value of contrast-enhanced CT (CECT) versus non-enhanced low-dose CT (NECT) in the staging of advanced malignant melanoma with 18 F-fluordeoxyglucose (FDG) positron emission tomography (PET)/CT. In total, 50 18 F-FDG PET/CT examinations were performed in 50 patients with metastasized melanoma. For attenuation correction, whole-body NECT was performed followed by diagnostic CECT with contrast agent. For the whole-body PET, 18 F-FDG was applied. Criteria for evaluation were signs of vital tumour tissue (extent of lesions, contrast enhancement, maximum standardized uptake value >2.5). Findings suspicious for melanoma were considered lesions. NECT, CECT and 18 F-FDG PET were evaluated separately, followed by combined analysis of PET/NECT and PET/CECT. Findings were verified histologically and/or by follow-up (>6 months). Overall, 232 lesions were analysed, and 151 proved to be metastases. The sensitivity of NECT, CECT, PET, PET/NECT and PET/CECT was 62, 85, 90, 97 and 100%, and specificity was 52, 63, 88, 93 and 93%, respectively. Compared to CECT, NECT obtained additional false-negative results: lymph node (n = 19) and liver/spleen metastases (n = 9). Misinterpreted physiological structures mainly caused additional false-positive findings (n = 17). In combined analysis of PET/NECT, six false-positive [other tumours (n = 2), inflammatory lymph nodes (n = 2), inflammatory lung lesion (n = 1), blood vessel (n = 1)] and five false-negative findings [liver (n = 3), spleen (n = 1), lymph node metastases (n = 1)] remained. On PET/CECT, six false-positive [inflammatory lymph nodes (n = 3), other tumours (n = 2), inflammatory lung lesion (n = 1)] and no false-negative findings occurred. However, additional false findings on PET/NECT (6 of 232) did not change staging compared to PET/CECT. Our results indicate that it is justified to perform PET/NECT instead of PET/CECT for melanoma staging. (orig.)

  2. The bases for the use of interpolation in helical computed tomography: an explanation for radiologists

    International Nuclear Information System (INIS)

    Garcia-Santos, J. M.; Cejudo, J.

    2002-01-01

    In contrast to conventional computed tomography (CT), helical CT requires the application of interpolators to achieve image reconstruction. This is because the projections processed by the computer are not situated in the same plane. Since the introduction of helical CT. a number of interpolators have been designed in the attempt to maintain the thickness of the reconstructed section as close as possible to the thickness of the X-ray beam. The purpose of this article is to discuss the function of these interpolators, stressing the advantages and considering the possible inconveniences of high-grade curved interpolators with respect to standard linear interpolators. (Author) 7 refs

  3. Low dose coronary CT angiography with 256-slice helical CT

    International Nuclear Information System (INIS)

    Zhang Xiaodong; Tang Binghang; Li Fangyun

    2011-01-01

    of 573) in B, 96.1% (548 of 570) in C, and 85.7% (505/589) in D, with no significant difference for A vs C (Z= -1.351, P>0.05) and with significant differences for B vs D (Z=-2.236, P<0.05). Linear correlation analysis indicated a significant degradation of image quality with the increase of heart rate using SAS mode (Spearman correlation, r=0.577, P<0.01). ROC analysis established an upper HR threshold of 78 bpm for obtaining diagnostic image quality using SAS mode (AUC = 0.827, P<0.05). The average radiation dose in group A [(2.6±0.5) mSv] reduced 75% comparing with that in group C [(10.6±2.3) mSv], and the average radiation dose in group B [(4.0±0.7) mSv] reduced 69% comparing with that in group D [(13.0±1.4) mSv]. Conclusion: Using SAS mode to perform low-dose CCTA with 256-slice helical CT could keep the image quality and reduce radiation dose significantly. Our preliminary experience suggests a good promise of this technique which could be applied to a wider group of patients such as with higher heart rates. (authors)

  4. Prevalence and characteristics of intravertebral enhancement on contrast-enhanced CT scans in cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Rasselet, Benjamin [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Larbi, Ahmed; Viala, Pierre [Medical Imaging Department, Nimes University Hospital, 4 rue du Professeur Robert Debré, 30029 Nîmes (France); Molinari, Nicolas [Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Tetreau, Raphael [Medical Imaging Department, Montpellier Cancer Institute (ICM), 208 Avenue des Apothicaires, 34298 Montpellier Cedex 5 (France); Faruch-Bilfeld, Marie [Medical Imaging Department, Toulouse University Hospital, Place du Docteur Baylac, 31059 Toulouse Cedex 9 (France); Taourel, Patrice [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Cyteval, Catherine, E-mail: c-cyteval@chu-montpellier.fr [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France)

    2017-01-15

    Highlights: • 2.8% of collateral venous circulation seen on CT scan in a cancer population. • 37% of intravertebral enhancement in this population with collateral venous circulation. • 80.8% of intravertebral enhancements are located between C6 and. • 73% of intravertebral enhancements are located ipsilateral to the injection side. -  Abstract: Study design: This was a single center, retrospective observational study. Objective: to investigate—in a cancer population—the prevalence and hallmarks of intravertebral enhancement (IVE) detected on contrast-enhanced CT. Summary of background data: Intravertebral enhancements secondary to iodinated contrast stagnation have been described. Cancer patients have an increased risk of perivertebral venous thrombosis or stenosis secondary to several risk factors (cancer or drug induced hypercoagulability, deterioration of venous flow linked to catheter insertion, prolonged immobilization). In case of a high density lesion identified on CT, the diagnostic choice between metastasis and contrast media within bone marrow vessels may be an issue, especially as oncologic follow-up CT scans are usually performed with contrast medium injection. Methods: 2572 contrast-enhanced body CT scans performed in cancer patients over 3 months in the medical imaging department of a university hospital were retrospectively reviewed. IVE was sought when paravertebral venous collateral circulation was detected and bone metastasis ruled out and classified as linear or nodular. Their locations within vertebra, their relation to the injection side and the predominant collateral venous network side were evaluated. Results: Sixty-seven (2.8%) patients had a collateral paravertebral venous system and among them 21 had IVE (37%). There were 208 IVE locations involving 75 vertebrae. 199 IVE were linear-shaped (95.7%) and 9 nodular-shaped (4.3%). 80.8% were located between C6 and T4. 88.9% were localized in the vertebral body. 73.1% were located

  5. Prevalence and characteristics of intravertebral enhancement on contrast-enhanced CT scans in cancer patients

    International Nuclear Information System (INIS)

    Rasselet, Benjamin; Larbi, Ahmed; Viala, Pierre; Molinari, Nicolas; Tetreau, Raphael; Faruch-Bilfeld, Marie; Taourel, Patrice; Cyteval, Catherine

    2017-01-01

    Highlights: • 2.8% of collateral venous circulation seen on CT scan in a cancer population. • 37% of intravertebral enhancement in this population with collateral venous circulation. • 80.8% of intravertebral enhancements are located between C6 and. • 73% of intravertebral enhancements are located ipsilateral to the injection side. -  Abstract: Study design: This was a single center, retrospective observational study. Objective: to investigate—in a cancer population—the prevalence and hallmarks of intravertebral enhancement (IVE) detected on contrast-enhanced CT. Summary of background data: Intravertebral enhancements secondary to iodinated contrast stagnation have been described. Cancer patients have an increased risk of perivertebral venous thrombosis or stenosis secondary to several risk factors (cancer or drug induced hypercoagulability, deterioration of venous flow linked to catheter insertion, prolonged immobilization). In case of a high density lesion identified on CT, the diagnostic choice between metastasis and contrast media within bone marrow vessels may be an issue, especially as oncologic follow-up CT scans are usually performed with contrast medium injection. Methods: 2572 contrast-enhanced body CT scans performed in cancer patients over 3 months in the medical imaging department of a university hospital were retrospectively reviewed. IVE was sought when paravertebral venous collateral circulation was detected and bone metastasis ruled out and classified as linear or nodular. Their locations within vertebra, their relation to the injection side and the predominant collateral venous network side were evaluated. Results: Sixty-seven (2.8%) patients had a collateral paravertebral venous system and among them 21 had IVE (37%). There were 208 IVE locations involving 75 vertebrae. 199 IVE were linear-shaped (95.7%) and 9 nodular-shaped (4.3%). 80.8% were located between C6 and T4. 88.9% were localized in the vertebral body. 73.1% were located

  6. Prognostic significance of contrast-enhanced CT attenuation value in extrahepatic cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, Yoshiki [Kyushu University, Department of Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Honda, Hiroshi [Kyushu University, Departments of Clinical Radiology, Fukuoka (Japan); Ohtsuka, Takao [Kyushu University, Departments of Surgery and Oncology, Fukuoka (Japan); Yoshizumi, Tomoharu [Kyushu University, Departments of Surgery and Sciences, Fukuoka (Japan); Aishima, Shinichi [Saga University, Pathology and Microbiology, Faculty of Medicine, Saga (Japan); Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan); Oda, Yoshinao [Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-06-15

    To determine whether washout characteristics of dynamic contrast-enhanced computed tomography (CT) could predict survival in patients with extrahepatic cholangiocarcinoma (EHC). This study collected 46 resected cases. All cases were examined by dynamic contrast study on multidetector-row CT. Region-of-interest measurements were obtained at the non-enhanced, portal venous phase and delayed phase in the tumour and were used to calculate the washout ratio as follows: [(attenuation value at portal venous phase CT - attenuation value at delayed enhanced CT)/(attenuation value at portal venous phase CT - attenuation value at unenhanced CT)] x 100. On the basis of the median washout ratio, we classified the cases into two groups, a high-washout group and low-washout group. Associations between overall survival and various factors including washout rates were analysed. The median washout ratio was 29.4 %. Univariate analysis revealed that a lower washout ratio, venous invasion, lymphatic permeation and lymph node metastasis were associated with shorter survival. Multivariate analysis identified the lower washout ratio as an independent prognostic factor (hazard ratio, 3.768; p value, 0.027). The washout ratio obtained from the contrast-enhanced CT may be a useful imaging biomarker for the prediction of survival of patients with EHC. (orig.)

  7. The value of contrast-enhanced CT scan in prediction of development of contusional hemorrhage

    International Nuclear Information System (INIS)

    Yokoyama, Kazuhiro; Kyoi, Kikuo; Sakaki, Toshisuke; Kinugawa, Kazuhiko; Morimoto, Tetsuya

    1983-01-01

    It is often experienced that even if there are no significant findings on the initial plain CT scan in the patient with cerebral contusion, the patient has thereafter a serious clinical course and requires emergency operation for so-called contusional hemorrhage. In order to predict of the development of contusional hemorrhage we performed contrast-enhanced CT scan at the time of patient's arrival within 12 hours after injury, if there was cerebral contusion on the initial plain CT scan, and repeated plain CT scan 24 hours after the contrast-enhanced CT scan. If enhancement was demonstrated on the contrastenhanced CT scan, we predicted the development of contusional hemorrhage and if not demonstrated, we predicted no more development of contusional hemorrhage and then we studied the correlation between the prediction and the plain CT 24 hours after the contrast-enhanced CT scan. The results were as follows: 1) The prediction was correct in 13 cases out of 16 cases in which the development of contusional hemorrhage was observed. In 18 cases where no development of contusional hemorrhage was observed, the prediction was correct without exception. 2) Most of the cases in which enhancement was demonstrated were ones examined not before 3 hours after injury. 3) The extent of enhancement shown on contrastenhanced CT scan was well consistent with that of contusional hemorrhage on the plain CT scan 24 hours after the contrast-enhanced CT scan. From these results, the contrast-enhanced CT scan in acute stage of head injury was considered to by very useful in prediction of the development of contusional hemorrhage. (author)

  8. Comparision between biphasic helical CT and dynamic gadolinium-enhanced MR in the detection and characterization of focal hepatic lesions in cirrhotic patients

    International Nuclear Information System (INIS)

    Puig, J.; Martin, J.; Donoso, L.; Falco, J.; Rue, M.

    1997-01-01

    To assess the agreement between biphasic helical computerized tomography (BHCT) and dynamic gadolinium-enhanced magnetic resonance (MR) in the detection and characterization of focal hepatic lesions in a group of cirrhotic patients. A prospective study was done in 50 cirrhotic patients suspected of having hepatocarcinoma (HC) on the basis of ultrasonographic images evaluated by means of BHCT and dynamic gadolinium-enhanced MR using fast low-angle shot (FLASH) sequences (110-135/4/90 degree centigree). The images were assessed jointly by four radiologists. Between the two techniques, a total of 83 lesions were detected. MR disclosed more lesions (n=79) than BHCT (n=67) (p<0.005). Moreover, 25 of the lesions that were visible by both techniques were more clearly evident in MR images (p<0.01). MR correctly classified 6 of 7 benign lesions (85%) and 49 of 66 malignant ones (74%). BHCT correctly classifed 2 of 7 benign lesions (28%) and 32 of 66 malignant ones (48%). The sensitivities of MR and BHCT for the characterization of these lesions were 74% and 48%, respectively (p=0.0009), while the respective specificities were 86% and 29% (P<0.001). Dynamic gadolinium-enhanced MR with FLASH sequences is more efficient than BHCT in the detection and characterization of focal lesions in cirrhotic patients. (Author) 37 refs

  9. A theoretically exact reconstruction algorithm for helical cone-beam differential phase-contrast computed tomography

    International Nuclear Information System (INIS)

    Li Jing; Sun Yi; Zhu Peiping

    2013-01-01

    Differential phase-contrast computed tomography (DPC-CT) reconstruction problems are usually solved by using parallel-, fan- or cone-beam algorithms. For rod-shaped objects, the x-ray beams cannot recover all the slices of the sample at the same time. Thus, if a rod-shaped sample is required to be reconstructed by the above algorithms, one should alternately perform translation and rotation on this sample, which leads to lower efficiency. The helical cone-beam CT may significantly improve scanning efficiency for rod-shaped objects over other algorithms. In this paper, we propose a theoretically exact filter-backprojection algorithm for helical cone-beam DPC-CT, which can be applied to reconstruct the refractive index decrement distribution of the samples directly from two-dimensional differential phase-contrast images. Numerical simulations are conducted to verify the proposed algorithm. Our work provides a potential solution for inspecting the rod-shaped samples using DPC-CT, which may be applicable with the evolution of DPC-CT equipments. (paper)

  10. Advances in CT imaging for urolithiasis

    Directory of Open Access Journals (Sweden)

    Yasir Andrabi

    2015-01-01

    Full Text Available Urolithiasis is a common disease with increasing prevalence worldwide and a lifetime-estimated recurrence risk of over 50%. Imaging plays a critical role in the initial diagnosis, follow-up and urological management of urinary tract stone disease. Unenhanced helical computed tomography (CT is highly sensitive (>95% and specific (>96% in the diagnosis of urolithiasis and is the imaging investigation of choice for the initial assessment of patients with suspected urolithiasis. The emergence of multi-detector CT (MDCT and technological innovations in CT such as dual-energy CT (DECT has widened the scope of MDCT in the stone disease management from initial diagnosis to encompass treatment planning and monitoring of treatment success. DECT has been shown to enhance pre-treatment characterization of stone composition in comparison with conventional MDCT and is being increasingly used. Although CT-related radiation dose exposure remains a valid concern, the use of low-dose MDCT protocols and integration of newer iterative reconstruction algorithms into routine CT practice has resulted in a substantial decrease in ionizing radiation exposure. In this review article, our intent is to discuss the role of MDCT in the diagnosis and post-treatment evaluation of urolithiasis and review the impact of emerging CT technologies such as dual energy in clinical practice.

  11. Experimental Evidence of Helical Flow in Porous Media

    DEFF Research Database (Denmark)

    Ye, Yu; Chiogna, Gabriele; Cirpka, Olaf A.

    2015-01-01

    Helical flow leads to deformation of solute plumes and enhances transverse mixing in porous media. We present experiments in which macroscopic helical flow is created by arranging different materials to obtain an anisotropic macroscopic permeability tensor with spatially variable orientation....... The resulting helical flow entails twisting streamlines which cause a significant increase in lateral mass exchange and thus a large enhancement of plume dilution (up to 235%) compared to transport in homogenous media. The setup may be used to effectively mix solutes in parallel streams similarly to static...... mixers, but in porous media....

  12. Dynamic evaluation of pelvic floor reconstructive surgery using radiopaque meshes and three-dimensional helical CT

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2010-04-01

    Full Text Available PURPOSE: This prospective study was performed to achieve visualization of the reestablishment of anatomy after reconstructive surgery in the different pelvic compartments with non-absorbable radiopaque meshes, providing valuable anatomic information for surgeons implanting meshes. MATERIALS AND METHODS: A total of 30 female patients with stress urinary incontinence (SUI, anterior and posterior vaginal wall prolapse, or both underwent surgical repair using radiopaque meshes after written informed consent. Patients with SUI underwent five different surgeries. Patients with anterior vaginal prolapse underwent a procedure using a combined pre-pubic and transobturator mesh, and those with posterior vaginal prolapse underwent posterior slingplasty. Three-dimensional reconstruction using helical CT was performed four weeks postoperatively. RESULTS: In all cases, the mesh was clearly visualized. Transobturator slings were shown at the midurethra, and the anchoring tails perforated the obturator foramen at the safety region. Mini-slings were in the proper place, and computed angiography revealed that the anchoring system was away from the obturator vessels. In patients undergoing procedure for anterior vaginal prolapse, both pre-pubic armpit and obturator slings were clearly seen and the mesh was in the proper position, supporting the bladder base and occluding the distal part of the urogenital hiatus. Transcoccygeal sacropexy revealed indirectly a well-supported "neo rectovaginal fascia" and the anchoring tails at the level of ischial spines. CONCLUSION: Three-dimensional helical tomography images of the female pelvis using radiopaque meshes have a potential role in improving our understanding of pelvic floor reconstructive surgeries. These radiopaque meshes might be the basis of a new investigative methodology.

  13. Dynamic CT findings of pulmonary hamartoma: A comparison with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Wanglae; Jeong, Yeon Joo; Lee, Chang Hun; Lee, Ji Won; Kim, Yeong Dae [Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan (Korea, Republic of); Kim, Kun Il [Dept. of Radiology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine and Medical Research Institute, Yangsan (Korea, Republic of)

    2013-12-15

    Describe the dynamic CT findings of pulmonary hamartoma and to compare these findings with histopathologic findings. he Institutional Review Board approved this retrospective study and the requirement for patient informed consent was waived. The hemodynamic CT features of 11 patients (M : F = 6 : 5; mean age, 53.6 years) with pathologically proven pulmonary hamartoma were evaluated. All 11 patients underwent enhanced dynamic CT using a helical technique. A series of images were obtained throughout each nodule with 2.5-mm collimation at 0, 30, 60, 90 and 120 seconds and at 4, 5 and 15 minutes after an intravenous injection of contrast medium. Extents and patterns of enhancement were correlated with histologic tumor components. ll 11 tumors showed persistent enhancement with variable degrees of net enhancement [mean tumor peak enhancement, 48.6 ± 19.0 Hounsfield unit (HU); mean tumor net enhancement, 31.9 ± 11.8 HU] and thick capsular and septal enhancement. Histologically, all 11 tumors were composed of mature cartilage and loose mesenchymal tissue. A significant positive correlation was found between the net enhancement values and loose connective tissue component percentages (r = 0.749, p = 0.008); further, a negative correlation was found between the net enhancement values and cartilaginous component percentages (r = -0.813, p = 0.002). n dynamic CT, hamartoma exhibited persistent enhancement without washout as well as thick capsular and septal enhancements. Net enhancement values were found to be positively correlated with the proportion of the loose connective tissue component. Thick capsular and septal enhancements were attributed histopathologically to loose connective tissue, separating tumors into cartilaginous lobules.

  14. Dynamic CT findings of pulmonary hamartoma: A comparison with histopathologic findings

    International Nuclear Information System (INIS)

    Cho, Wanglae; Jeong, Yeon Joo; Lee, Chang Hun; Lee, Ji Won; Kim, Yeong Dae; Kim, Kun Il

    2013-01-01

    Describe the dynamic CT findings of pulmonary hamartoma and to compare these findings with histopathologic findings. he Institutional Review Board approved this retrospective study and the requirement for patient informed consent was waived. The hemodynamic CT features of 11 patients (M : F = 6 : 5; mean age, 53.6 years) with pathologically proven pulmonary hamartoma were evaluated. All 11 patients underwent enhanced dynamic CT using a helical technique. A series of images were obtained throughout each nodule with 2.5-mm collimation at 0, 30, 60, 90 and 120 seconds and at 4, 5 and 15 minutes after an intravenous injection of contrast medium. Extents and patterns of enhancement were correlated with histologic tumor components. ll 11 tumors showed persistent enhancement with variable degrees of net enhancement [mean tumor peak enhancement, 48.6 ± 19.0 Hounsfield unit (HU); mean tumor net enhancement, 31.9 ± 11.8 HU] and thick capsular and septal enhancement. Histologically, all 11 tumors were composed of mature cartilage and loose mesenchymal tissue. A significant positive correlation was found between the net enhancement values and loose connective tissue component percentages (r = 0.749, p = 0.008); further, a negative correlation was found between the net enhancement values and cartilaginous component percentages (r = -0.813, p = 0.002). n dynamic CT, hamartoma exhibited persistent enhancement without washout as well as thick capsular and septal enhancements. Net enhancement values were found to be positively correlated with the proportion of the loose connective tissue component. Thick capsular and septal enhancements were attributed histopathologically to loose connective tissue, separating tumors into cartilaginous lobules.

  15. Dynamics of zonal flows in helical systems.

    Science.gov (United States)

    Sugama, H; Watanabe, T-H

    2005-03-25

    A theory for describing collisionless long-time behavior of zonal flows in helical systems is presented and its validity is verified by gyrokinetic-Vlasov simulation. It is shown that, under the influence of particles trapped in helical ripples, the response of zonal flows to a given source becomes weaker for lower radial wave numbers and deeper helical ripples while a high-level zonal-flow response, which is not affected by helical-ripple-trapped particles, can be maintained for a longer time by reducing their bounce-averaged radial drift velocity. This implies a possibility that helical configurations optimized for reducing neoclassical ripple transport can simultaneously enhance zonal flows which lower anomalous transport.

  16. Implementation techniques and acceleration of DBPF reconstruction algorithm based on GPGPU for helical cone beam CT

    International Nuclear Information System (INIS)

    Shen Le; Xing Yuxiang

    2010-01-01

    The derivative back-projection filtered algorithm for a helical cone-beam CT is a newly developed exact reconstruction method. Due to its large computational complexity, the reconstruction is rather slow for practical use. General purpose graphic processing unit (GPGPU) is an SIMD paralleled hardware architecture with powerful float-point operation capacity. In this paper,we propose a new method for PI-line choice and sampling grid, and a paralleled PI-line reconstruction algorithm implemented on NVIDIA's Compute Unified Device Architecture (CUDA). Numerical simulation studies are carried out to validate our method. Compared with conventional CPU implementation, the CUDA accelerated method provides images of the same quality with a speedup factor of 318. Optimization strategies for the GPU acceleration are presented. Finally, influence of the parameters of the PI-line samples on the reconstruction speed and image quality is discussed. (authors)

  17. Detection of breast abnormalities on enhanced chest CT: Correlation with breast composition on mammography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eun Mi; Kang, Hee; Shin, Young Gyung; Yun, Jong Hyouk; Oh, Kyung Seung [Dept. of Radiology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan (Korea, Republic of)

    2017-02-15

    To investigate the capability of enhanced chest computed tomography (CT) for detecting breast abnormalities and to assess the influence of breast composition on this detectability. From 2000 to 2013, 75 patients who underwent mammography, breast sonography, and enhanced chest CT within one month and had abnormalities on sonography were included. Detection rate of breast abnormality on enhanced chest CT was compared among 4 types of breast composition by the Breast Imaging Reporting and Data System. Contribution of breast composition, size and enhancement of target lesions to detectability of enhanced chest CT was assessed using logistic regression and chi-square test. Of the 75 target lesions, 34 (45.3%) were detected on enhanced chest CT, corresponding with those on breast sonography; there were no significantly different detection rates among the 4 types of breast composition (p = 0.078). Breast composition [odds ratio (OR) = 1.07, p = 0.206] and enhancement (OR = 21.49, p = 0.998) had no significant effect, but size (OR = 1.23, p = 0.004) was a significant contributing factor influencing the detectability of enhanced chest CT for breast lesions. About half of the cases (45.3%) demonstrated breast lesions on chest CT corresponding with target lesions on sonography. Breast composition defined on mammography did not affect the detectability of enhanced chest CT for breast lesions.

  18. Histopathologic diversity of gastric cancers: Relationship between enhancement pattern on dynamic contrast-enhanced CT and histological type.

    Science.gov (United States)

    Tsurumaru, Daisuke; Miyasaka, Mitsutoshi; Muraki, Toshio; Nishie, Akihiro; Asayama, Yoshiki; Oki, Eiji; Oda, Yoshinao; Honda, Hiroshi

    2017-12-01

    To evaluate the diagnostic value of contrast-enhanced computed tomography gastrography (CE-CTG) to predict the histological type of gastric cancer. We analyzed 47 consecutive patients with resectable advanced gastric cancer preoperatively evaluated by multiphasic dynamic contrast-enhanced CT. Two radiologists independently reviewed the CT images and they determined the peak enhancement phase, and then measured the CT attenuation value of the gastric lesion for each phase. The histological types of gastric cancers were assigned to three groups as differentiated-type, undifferentiated-type, and mixed-type. We compared the peak enhancement phase of the three types and compared the CT attenuation values in each phase. The peak enhancement was significantly different between the three types of gastric cancers for both readers (reader 1, p=0.001; reader 2, p=0.009); most of the undifferentiated types had peak enhancement in the delayed phase. The CT attenuation values of undifferentiated type were significantly higher than those of differentiated or mixed type in the delayed phase according to both readers (reader 1, p=0.002; reader 2, p=0.004). CE-CTG could provide helpful information in diagnosing the histological type of gastric cancers preoperatively. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. {sup 18}F-FDG PET/CT and contrast-enhanced CT findings of pulmonary cryptococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Si-yun, E-mail: wang_shuxia@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Chen, Gang, E-mail: cgggh@outlook.com [Department of Thoracic Surgery, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Luo, Dong-lan, E-mail: 695532870@qq.com [Department of Pathology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Shao, Dan, E-mail: shaodan501@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Liu, En-tao, E-mail: GDGH2015@gmail.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Sun, Taotao, E-mail: sunmoodsdaisy@bjmu.edu.cn [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Wang, Shu-Xia, E-mail: wsyggh@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China)

    2017-04-15

    Purpose: Pulmonary cryptococcosis is an uncommon cause of pulmonary nodules in non-AIDS patients. This study reports the {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET/CT) and contrast-enhanced CT (CE-CT) findings of 42 patients with pulmonary cryptococcosis. Materials and methods: A retrospective review of the {sup 18}F-FDG PET/CT and CE-CT findings of 42 patients with histologically proven pulmonary cryptococcosis was conducted. All patients underwent PET/CT and CE-CT in the same session. The CT diagnosis was based on the location, morphological features, and enhancement of lesions. The PET/CT findings were recorded, and clinical data and surgical and histopathological findings were collected. Results: The results of the PET scans revealed that 37 (88%) of 42 patients showed higher FDG uptake, and 5 (12%) patients demonstrated lower FDG uptake than the mediastinal blood pool. The maximum standardized uptake value (SUV) of pulmonary cryptococcosis ranged from 1.4 to 13.0 (average: 5.7 ± 3.3, median 4.9). A single nodular pattern was the most prevalent pattern observed and was found in 29 (69%) patients. This pattern was followed by scattered nodular (n = 4, 10%), clustered nodular (n = 3, 7%), mass-like (n = 3, 7%), and bronchopneumonic (n = 3, 7%) patterns. The most frequent pattern of immunocompetent patients was the single nodular pattern (29 of 33, 88%). Immunocompromised patients most frequently pattern exhibited mass-like (3 of 9, 33%) and bronchopneumonic (3 of 9, 33%) patterns. Conclusion: Pulmonary cryptococcosis most commonly appears as single nodules in immunocompetent patients. Mass-like and bronchopneumonic patterns were common in immunocompromised patients. In 88% of patients, lung lesions showed high FDG uptake, thus mimicking a possible malignant condition.

  20. Efficacy of helical CT in evaluating local tumor extent of breast cancer

    International Nuclear Information System (INIS)

    Ozaki, Yutaka

    2001-01-01

    The purpose of this study is to clarify the diagnostic accuracy of helical CT (HCT) in the determination of local tumor extent of breast cancer. One hundred forty consecutive patients with breast cancer, including 87 invasive ductal carcinomas without extensive intraductal components (EIC), 44 invasive ductal carcinomas with EIC, 2 non-invasive ductal carcinomas, and 7 invasive lobular carcinomas, were included in the study. Three-dimensional tumor diameter including whole extent was measured on HCT, and the amount of invasion to fat tissue, skin, pectoral muscle, and chest wall was estimated using a three-step scale. These results were then compared with the pathological findings. Breast cancers appeared as areas of high attenuation compared with the surrounding breast tissue in all patients. Tumor extent was correctly diagnosed by HCT to within a maximum difference of 1 cm in 88 patients (63%) and within 2 cm in 122 patients (87%). Sensitivity, specificity, and accuracy in diagnosing muscular invasion of breast cancer using HCT were 100%, 99%, and 99%, respectively. Sensitivity, specificity, and accuracy in diagnosing skin invasion of breast cancer using HCT were 84%, 93%, and 91%, respectively. HCT was able to visualize all of the tumors and detect the correct tumor extent in most patients. (author)

  1. Efficacy of helical CT in evaluating local tumor extent of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Yutaka [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2001-04-01

    The purpose of this study is to clarify the diagnostic accuracy of helical CT (HCT) in the determination of local tumor extent of breast cancer. One hundred forty consecutive patients with breast cancer, including 87 invasive ductal carcinomas without extensive intraductal components (EIC), 44 invasive ductal carcinomas with EIC, 2 non-invasive ductal carcinomas, and 7 invasive lobular carcinomas, were included in the study. Three-dimensional tumor diameter including whole extent was measured on HCT, and the amount of invasion to fat tissue, skin, pectoral muscle, and chest wall was estimated using a three-step scale. These results were then compared with the pathological findings. Breast cancers appeared as areas of high attenuation compared with the surrounding breast tissue in all patients. Tumor extent was correctly diagnosed by HCT to within a maximum difference of 1 cm in 88 patients (63%) and within 2 cm in 122 patients (87%). Sensitivity, specificity, and accuracy in diagnosing muscular invasion of breast cancer using HCT were 100%, 99%, and 99%, respectively. Sensitivity, specificity, and accuracy in diagnosing skin invasion of breast cancer using HCT were 84%, 93%, and 91%, respectively. HCT was able to visualize all of the tumors and detect the correct tumor extent in most patients. (author)

  2. Computed Tomography (CT) Scans and Cancer

    Science.gov (United States)

    ... Reporting & Auditing Grant Transfer Grant Closeout Contracts & Small Business Training Cancer Training at NCI (Intramural) Resources for ... companies (and Medicare) do not currently reimburse the costs of this procedure. Also, because CT ... the effectiveness of low-dose helical CT for lung cancer ...

  3. Enhanced CT in the diagnosis of acute appendicitis to evaluate the severity of disease. Comparison of CT findings and histological diagnosis

    International Nuclear Information System (INIS)

    Mori, Yoshiko; Yamasaki, Michio; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi

    2001-01-01

    To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of the appendiceal wall was observed in all 29 cases of phlegmonous appendicitis (100%), but in only 66.7% (18 cases) of gangrenous appendicitis. Deficiency of the appendiceal wall was more frequently observed in gangrenous (19/27, 70.4%) than phlegmonous appendicitis (4/29, 13.8%). Findings of enhanced CT provide useful information in evaluating the pathological severity of acute appendicitis. (author)

  4. Radiation dosage of various CT-methods in lung diagnostics

    International Nuclear Information System (INIS)

    Heinz-Peer, G.; Weninger, F.; Nowotny, R.; Herold, C.J.

    1996-01-01

    Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to difference in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry ('generation'), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing. (orig.) [de

  5. CT features of abdominal plasma cell neoplasms

    International Nuclear Information System (INIS)

    Monill, J.; Pernas, J.; Montserrat, E.; Perez, C.; Clavero, J.; Martinez-Noguera, A.; Guerrero, R.; Torrubia, S.

    2005-01-01

    The aim of this study was to describe the CT features of abdominal plasma cell neoplasms. We reviewed CT imaging findings in 11 patients (seven men, four women; mean age 62 years) with plasma cell neoplasms and abdominal involvement. Helical CT of the entire abdomen and pelvis was performed following intravenous administration of contrast material. Images were analyzed in consensus by two radiologists. Diagnoses were made from biopsy, surgery and/or clinical follow-up findings. Multiple myeloma was found in seven patients and extramedullary plasmacytoma in four patients. All patients with multiple myeloma had multifocal disease with involvement of perirenal space (4/7), retroperitoneal and pelvic lymph nodes (3/7), peritoneum (3/7), liver (2/7), subcutaneous tissues (2/7) and kidney (1/7). In three of the four patients with extramedullary plasmacytoma, a single site was involved, namely stomach, vagina and retroperitoneum. In the fourth patient, a double site of abdominal involvement was observed with rectal and jejunal masses. Plasma cell neoplasm should be considered in the differential diagnosis of single or multiple enhancing masses in the abdomen or pelvis. Abdominal plasma cell neoplasms were most frequently seen as well-defined enhancing masses (10/11). (orig.)

  6. Multimodality functional imaging of spontaneous canine tumors using 64CU-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    DEFF Research Database (Denmark)

    Hansen, Anders E; Kristensen, Annemarie T; Law, Ian

    2012-01-01

    To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated.......To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated....

  7. Addison's disease due to adrenal tuberculosis: Contrast-enhanced CT features and clinical duration correlation

    International Nuclear Information System (INIS)

    Guo Yingkun; Yang Zhigang; Li Yuan; Ma Ensen; Deng Yuping; Min Pengqiu; Yin Longlin; Hu Jian; Zhang Xiaochun; Chen Tianwu

    2007-01-01

    Purpose: To describe CT morphology of untreated adrenal tuberculosis during the different stages of the natural history of the disease and to evaluate the diagnostic implications of CT features. Materials and methods: We retrospectively evaluated CT features in 42 patients with documented adrenal tuberculosis for the location, size, morphology, and enhancement patterns shown on CT images. The clinical duration were correlated with the CT features. Results: Of the 42 patients with untreated adrenal tuberculosis, bilaterally enlarged adrenal glands were revealed in 38 cases (91%), unilaterally enlarged in 3 cases (7%), and normal size in 1 case (2%). Of the 41 cases (98%) with enlargement, mass-like enlargement was seen in 20 cases (49%) and enlargement with preserved contours in 21 cases (51%). Peripheral rim enhancement presented in 22 cases (52%) on contrast-enhanced CT. Non-enhanced CT scan revealed calcification in 21 cases (50%). As the duration of Addison's disease increased, the presence of calcification and contour preservation increased concomitantly (p < 0.001), whereas peripheral rim enhancement and mass-like enlargement decreased concomitantly on CT images (p < 0.001). Conclusion: CT may be helpful in diagnosing adrenal tuberculosis when clinically suspected, and CT features are correlated to the clinical duration of Addison's disease

  8. The Enhanced Intramolecular Energy Transfer and Strengthened ff Luminescence of a Stable Helical Eu Complex in Ionic Liquids

    Directory of Open Access Journals (Sweden)

    Yuki Hasegawa

    2018-01-01

    Full Text Available The luminescence of a Eu complex (EuL is enhanced by stabilization of the coordination structure in highly viscous ionic liquids. The EuL was found to maintain a stable single helical structure both in organic solvents and in the ionic liquids [BMIM][PF6] and [EMIM][PF6]. A colorless solution of EuL dissolved in [BMIM][PF6] exhibits bright red luminescence with a quantum yield of 32.3%, a value that is much higher than that in acetonitrile (12%. Estimated rate constants for the energy relaxation pathway indicate that the energy transfer efficiency is enhanced in [BMIM][PF6] as a result of the suppression of molecular fluctuations in the ligands. Additionally, a highly luminescent helical structure is preserved in [EMIM][PF6] up to 120 °C.

  9. Exploration of cervical carotid stenosis using helical CT angiography. A prospective trial on the detection of candidates for surgery in the Gujo area, Gifu

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Hiroyasu; Sumi, Yasuhiko [Sumi Hospital, Gifu (Japan); Kaku, Yasuhiko; Sakai, Noboru; Yamada, Hiromu

    1995-04-01

    To detect cervical carotid stenosis as a candidate for carotid endarterectomy (CEA), the authors attempted a prospective trial by exploring stenosis for one year in a rural district with a population of 20,000, employing helical CT angiography which apparently displayed three-dimensional reconstructed images of the carotid bifurcation. Thirty-three patients, 24 males and 9 females, with a mean age of 71.8 years, suffering from TIA, RIND or stroke were investigated for their carotid systems. The clinical symptoms of the patients were briefly as follows: motor weakness in 30 cases, dysarthria in 8 cases and aphasia in 4 cases; and 6 of 22 (27%) stroke cases had previously suffered an episode of TIA. The risk factors of the whole group of patients were hypertension in 13 cases, diabetes mellitus in 6, heart disease in 17, and hypercholesteremia in 4. Helical CT angiography was performed in 11 cases of TIA, 2 cases of RIND, and 16 cases of stroke. Only 3 cases of the TIA group and 3 cases of the stroke group were found to have extracranial carotid stenosis of more than 50%, which subsequently required conventional angiography. For the detection of stenosis, CT angiography was beneficial as well as conventional angiography. Finally, CEA was performed in 2 of 3 cases with severe carotid stonosis in the TIA group, while such cases in the stroke group were only observed. The above results meant that the occurrence of extracranial carotid stenosis was 6 out of 6,589 elderly inhabitants (over 60 years old), although the possible detection rate of candidates for CEA was 2 out of 20,000 population per year. (author).

  10. Exploration of cervical carotid stenosis using helical CT angiography. A prospective trial on the detection of candidates for surgery in the Gujo area, Gifu

    International Nuclear Information System (INIS)

    Yamakawa, Hiroyasu; Sumi, Yasuhiko; Kaku, Yasuhiko; Sakai, Noboru; Yamada, Hiromu.

    1995-01-01

    To detect cervical carotid stenosis as a candidate for carotid endarterectomy (CEA), the authors attempted a prospective trial by exploring stenosis for one year in a rural district with a population of 20,000, employing helical CT angiography which apparently displayed three-dimensional reconstructed images of the carotid bifurcation. Thirty-three patients, 24 males and 9 females, with a mean age of 71.8 years, suffering from TIA, RIND or stroke were investigated for their carotid systems. The clinical symptoms of the patients were briefly as follows: motor weakness in 30 cases, dysarthria in 8 cases and aphasia in 4 cases; and 6 of 22 (27%) stroke cases had previously suffered an episode of TIA. The risk factors of the whole group of patients were hypertension in 13 cases, diabetes mellitus in 6, heart disease in 17, and hypercholesteremia in 4. Helical CT angiography was performed in 11 cases of TIA, 2 cases of RIND, and 16 cases of stroke. Only 3 cases of the TIA group and 3 cases of the stroke group were found to have extracranial carotid stenosis of more than 50%, which subsequently required conventional angiography. For the detection of stenosis, CT angiography was beneficial as well as conventional angiography. Finally, CEA was performed in 2 of 3 cases with severe carotid stonosis in the TIA group, while such cases in the stroke group were only observed. The above results meant that the occurrence of extracranial carotid stenosis was 6 out of 6,589 elderly inhabitants (over 60 years old), although the possible detection rate of candidates for CEA was 2 out of 20,000 population per year. (author)

  11. Rare variations in renal anatomy and blood supply: CT appearances and embryological background. A pictorial essay

    International Nuclear Information System (INIS)

    Cocheteux, B.; Gaxotte, V.; Beregi, J.P.; Mounier-Vehier, C.; McFadden, E.P.; Francke, J.P.

    2001-01-01

    Helical CT angiography is increasingly used for the evaluation of the kidneys and the renal vessels. Knowledge of the potential variants in renal and renal vascular anatomy and of their appearances on helical CT are thus indispensable for radiologists who perform and interpret such examinations. We report six cases of anatomic variants that we encountered in our tertiary referral centre over the past 5 years, during which time we have performed 4850 helical CT angiograms, including 1432 renal artery examinations. These represent rarer anomalies in renal vascularization, most of which were associated with renal malformations (horseshoe kidney with or without cortical torsion, renal malrotation, single kidney, and thoracic origin of a renal artery). We present the helical CT findings and discuss the possible embryological mechanisms and the practical implications of these abnormalities for the radiologist. (orig.)

  12. Rare variations in renal anatomy and blood supply: CT appearances and embryological background. A pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Cocheteux, B.; Gaxotte, V.; Beregi, J.P. [Dept. of Vascular Radiology, Hopital Cardiologique, CHRU de Lille (France); Mounier-Vehier, C. [Service d' Hypertension Arterielle et Medecine Interne, Hopital Cardiologique, CHRU de Lille (France); McFadden, E.P. [Service de Cardiologie B, Hopital Cardiologique, CHRU de Lille (France); Francke, J.P. [Lab. d' Anatomie, Faculte de Medecine, Lille (France)

    2001-05-01

    Helical CT angiography is increasingly used for the evaluation of the kidneys and the renal vessels. Knowledge of the potential variants in renal and renal vascular anatomy and of their appearances on helical CT are thus indispensable for radiologists who perform and interpret such examinations. We report six cases of anatomic variants that we encountered in our tertiary referral centre over the past 5 years, during which time we have performed 4850 helical CT angiograms, including 1432 renal artery examinations. These represent rarer anomalies in renal vascularization, most of which were associated with renal malformations (horseshoe kidney with or without cortical torsion, renal malrotation, single kidney, and thoracic origin of a renal artery). We present the helical CT findings and discuss the possible embryological mechanisms and the practical implications of these abnormalities for the radiologist. (orig.)

  13. An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studies

    International Nuclear Information System (INIS)

    Yazdia, Mehran; Gingras, Luc; Beaulieu, Luc

    2005-01-01

    Purpose: In this article, an approach to metal artifact reduction is proposed that is practical for clinical use in radiation therapy. It is based on a new interpolation scheme of the projections associated with metal implants in helical computed tomography (CT) scanners. Methods and Materials: A three-step approach was developed consisting of an automatic algorithm for metal implant detection, a correction algorithm for helical projections, and a new, efficient algorithm for projection interpolation. The modified raw projection data are transferred back to the CT scanner device where CT slices are regenerated using the built-in reconstruction operator. The algorithm was tested on a CT calibration phantom in which the density of inserted objects are known and on clinical prostate cases with two hip prostheses. The results are evaluated using the CT number and shape of the objects. Results: The validations on a CT calibration phantom with various inserts of known densities show that the algorithm improved the overall image quality by restoring the shape and the representative CT number of the objects in the image. For the clinical hip replacement cases, a large fraction of the bladder, rectum, and prostate that were not visible on the original CT slices were recovered using the algorithm. Precise contouring of the target volume was thus feasible. Without this enhancement, physicians would have drawn bigger margins to be sure to include the target and, at the same time, could have prescribed a lower dose to keep the same level of normal tissue toxicity. Conclusions: In both phantom experiment and patient studies, the algorithm resulted in significant artifact reduction with increases in the reliability of planning procedure for the case of metallic hip prostheses. This algorithm is now clinically used as a preprocessing before treatment planning for metal artifact reduction

  14. Differential diagnosis between pulmonary tuberculosis and lung abscess by contrast enhanced CT

    International Nuclear Information System (INIS)

    Kanauchi, Tetsu; Hoshi, Toshiko; Konno, Miyuki; Hando, Yumiko

    2001-01-01

    The contrast enhanced CT findings in 14 patients with active tuberculosis and 26 patients with lung abscess were retrospectively analyzed. Reflecting the difference of pathogenesis between tuberculosis and abscess, the findings are widely different. The findings suggesting pulmonary tuberculosis rather than lung abscess were as follows; multiple and irregular necrotic areas, positive CT angiogram sign, no marginal enhancement surrounding necrosis. Contrast enhanced CT may help to distinguish pulmonary tuberculosis from lung abscess, especially in cases of caseous pneumonia showing broad consolidations or mass-like shadows. (author)

  15. Intracranial ring enhancing lesions in dogs: a correlative CT scanning and neuropathologic study

    International Nuclear Information System (INIS)

    Wolf, Michael; Pedroia, Vince; Higgins, Robert J.; Koblik, Philip D.; Turrel, Jane M.; Owens, Jerry M.

    1995-01-01

    This retrospective analysis of 15 dogs with postcontrast ring enhancing brain lesions, each detected by a single Computed Tomography (CT) examination, searched for any association between their CT appearance and the pathologic diagnosis. In a subgroup of these dogs (n = 71) necropsied within 2 days of the last CT scan, we evaluated whether there was any anatomic correlation between the ring zone and the histopathologic features of the lesions. Our study consisted of eight dogs with primary brain tumors (3 meningiomas, 3 astrocytomas, 1 mixed glioma, 1 oligodendroglioma), 4 with metastatic brain tumors (2 fibrosarcomas, 1 mammary carcinoma, 1 melanoma) and 3 with non-neoplastic brain lesions (2 intraparenchymal hemorrhages, 1 pyogranulomatous meningoencephalitis). The overall size and shape of the contrast enhancing CT lesions, as well as the thickness, surface texture and degree of enhancement of the ring were subjectively evaluated. No association was found between the CT lesion characteristics and the pathologic diagnosis. In the sub-group of dogs euthanatized within 2 days of the CT examination, distinct histologic features which anatomically correlated with the zone of ring enhancement were found in 3 of 7 lesions. The findings of this study are consistent with those of ring-enhancing lesions in people, and indicates that CT ring enhancement is a nonspecific phenomenon which can occur in a variety of neoplastic and non-neoplastic lesions in the dog

  16. Blunt trauma to the gastrointestinal tract and mesentery: is there a role for helical CT in the decision-making process?

    International Nuclear Information System (INIS)

    Scaglione, Mariano; de Lutio di Castelguidone, Elisabetta; Scialpi, Michele; Merola, Stefanella; Diettrich, Andrea Irma; Lombardo, Patrizia; Romano, Luigia; Grassi, Roberto

    2004-01-01

    The CT diagnosis of bowel and mesenteric injuries is difficult and warrants optimal technique and skilled interpretation. We retrospectively reviewed 36 consecutive patients with blunt traumatic injuries to the bowel and mesentery at our regional level I trauma center during the past 3 years. Physical examination, laboratory, Computed tomographic (CT), and intraoperative findings were compared. Surgically proven bowel injuries (13 cases) occurred in the duodenum (three cases), ileum (two cases), jejunum (two cases), colon (three cases), and stomach (three cases). CT findings considered specific of bowel rupture were observed in 5/13 patients including: extraluminal oral contrast or luminal content extravasation (four cases) and discontinuity of hollow viscus wall (one case). In the remaining 8/13 CT findings considered suggestive of bowel injury consisted of: pneumoperitoneum (six), gas bubbles close to the injured hollow viscus (three), thickened (>4-5 mm) bowel wall (five), bowel wall hematoma (three), intraperitoneal fluid of unknown source (three). Mesenteric injury (23 cases) were surgically observed at the level of the mesenteric vessels (17 cases), legament of Treitz (two cases), gastro-duodenal artery (one case), transverse (one case) and sigmoid mesocolon (one case). CT finding considered specific of mesenteric laceration was active extravasation of contrast material from the mesenteric vessels (10 cases). CT findings suggestive of mesenteric injury (13 cases) consisted of: mesenteric hematoma (five) and/or high attenuation fluid collections, within the mesenteric root (eight) and folds (four). Helical CT is sensitive in the identification of bowel and mesenteric injury after blunt trauma providing a wide spectrum of findings. However, CT cannot be used as the sole indicator in cases with isolated thickened bowel wall, mesenteric hematoma, bowel hematoma, pneumoperitoneum or gas bubbles. Persistent, active extravasation of intravenous contrast medium from

  17. Predicting IDH mutation status of intrahepatic cholangiocarcinomas based on contrast-enhanced CT features

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yong [Nanjing Drum Tower Hospital Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Department of Radiology, Nanjing, Jiangsu Province (China); Chen, Jun [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Pathology, Nanjing, Jiangsu Province (China); Kong, Weiwei [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Oncology, Nanjing, Jiangsu Province (China); Mao, Liang; Qiu, Yudong [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Hepatopancreatobiliary Surgery, Nanjing, Jiangsu Province (China); Kong, Wentao [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Ultrasonography, Nanjing, Jiangsu Province (China); Zhou, Qun [Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Department of Radiology, Nanjing, Jiangsu Province (China); Zhou, Zhengyang; Zhu, Bin; He, Jian [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Radiology, Nanjing, Jiangsu Province (China); Wang, Zhongqiu [Jiangsu Province Hospital of Traditional Chinese Medicine, the Affiliated Hospital of Nanjing University of Chinese Medicine, Department of Radiology, Nanjing, Jiangsu Province (China)

    2018-01-15

    To explore the difference in contrast-enhanced computed tomography (CT) features of intrahepatic cholangiocarcinomas (ICCs) with different isocitrate dehydrogenase (IDH) mutation status. Clinicopathological and contrast-enhanced CT features of 78 patients with 78 ICCs were retrospectively analysed and compared based on IDH mutation status. There were 11 ICCs with IDH mutation (11/78, 14.1%) and 67 ICCs without IDH mutation (67/78, 85.9%). IDH-mutated ICCs showed intratumoral artery more often than IDH-wild ICCs (p = 0.023). Most ICCs with IDH mutation showed rim and internal enhancement (10/11, 90.9%), while ICCs without IDH mutation often appeared diffuse (26/67, 38.8%) or with no enhancement (4/67, 6.0%) in the arterial phase (p = 0.009). IDH-mutated ICCs showed significantly higher CT values, enhancement degrees and enhancement ratios in arterial and portal venous phases than IDH-wild ICCs (all p < 0.05). The CT value of tumours in the portal venous phase performed best in distinguishing ICCs with and without IDH mutation, with an area under the curve of 0.798 (p = 0.002). ICCs with and without IDH mutation differed significantly in arterial enhancement mode, and the tumour enhancement degree on multiphase contrast-enhanced CT was helpful in predicting IDH mutation status. (orig.)

  18. Helical tomotherapy. Experiences of the first 150 patients in Heidelberg

    Energy Technology Data Exchange (ETDEWEB)

    Sterzing, F.; Schubert, K.; Sroka-Perez, G.; Kalz, J.; Debus, J.; Herfarth, K. [Dept. of Radiation Oncology, Univ. of Heidelberg (Germany)

    2008-01-15

    Background and purpose: helical tomotherapy was introduced into clinical routine at the Department of Radiation Oncology, University Hospital of Heidelberg, Germany, in July 2006. This report is intended to describe the experience with the first 150 patients treated with helical tomotherapy. Patient selection, time effort, handling of daily image guidance with megavoltage (MV) CT, and quality of radiation plans shall be assessed. Patients and methods: between July 2006 and May 2007, 150 patients were treated with helical tomotherapy in the University Hospital of Heidelberg. Mean age was 60 years with a minimum of 30 years and a maximum of 85 years. 79 of these patients received radiotherapy as a part of multimodal treatment pre- or postoperatively, 17 patients received treatment as a combined radiochemotherapy. 76% were treated with curative intent. Radiotherapy sites were central nervous system (n = 7), head and neck (n = 28), thoracic (n = 37), abdominal (n = 58) and skeletal system (n = 20). Most common tumor entities were prostate cancer (n = 28), breast cancer (n = 17), gastrointestinal tumors (n = 19), pharyngeal carcinoma (n = 14), lymphoma (n = 13), metastatic disease (bone n = 14, liver n = 6, lung n = 4, lymph node n = 2), sarcoma (n = 8), malignant pleural mesothelioma (n = 5), ovarian cancer treated with whole abdominal irradiation (n = 4), lung cancer (n = 3), skin malignancies (n = 3), chordoma (n = 2), meningioma (n = 2), one ependymoma and one medulloblastoma treated with craniospinal axis irradiation (n = 2), and others (n = 4). Nine patients were treated with single-fraction radiosurgery, nine with image-guided spinal reirradiation, and twelve patients were treated at multiple targets simultaneously. A pretreatment MV-CT scan was performed in 98.2% of the 3,026 fractions applied. After matching with the kilovoltage planning CT, corrections for translations and rotation around longitudinal axis (roll) were done. Results: mean time on table was 24

  19. Favorable noise uniformity properties of Fourier-based interpolation and reconstruction approaches in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    Volumes reconstructed by standard methods from single-slice helical computed tomography (CT) data have been shown to have noise levels that are highly nonuniform relative to those in conventional CT. These noise nonuniformities can affect low-contrast object detectability and have also been identified as the cause of the zebra artifacts that plague maximum intensity projection (MIP) images of such volumes. While these spatially variant noise levels have their root in the peculiarities of the helical scan geometry, there is also a strong dependence on the interpolation and reconstruction algorithms employed. In this paper, we seek to develop image reconstruction strategies that eliminate or reduce, at its source, the nonuniformity of noise levels in helical CT relative to that in conventional CT. We pursue two approaches, independently and in concert. We argue, and verify, that Fourier-based longitudinal interpolation approaches lead to more uniform noise ratios than do the standard 360LI and 180LI approaches. We also demonstrate that a Fourier-based fan-to-parallel rebinning algorithm, used as an alternative to fanbeam filtered backprojection for slice reconstruction, also leads to more uniform noise ratios, even when making use of the 180LI and 360LI interpolation approaches

  20. Lung scintigraphy and helical computed tomography for the diagnosis of pulmonary embolism : A meta-analysis

    NARCIS (Netherlands)

    van Beek, EJR; Brouwers, Elise M J; Song, B; Bongaerts, AHH; Oudkerk, M

    To assess the diagnostic value of lung scintigraphy and helical computed tomography (hCT) in patients with suspected pulmonary embolism (PE), all English-language articles that described lung scintigraphy and hCT in patients with suspected PE were retrieved. Articles were assessed for strength of

  1. The helical tomotherapy thread effect

    International Nuclear Information System (INIS)

    Kissick, M.W.; Fenwick, J.; James, J.A.; Jeraj, R.; Kapatoes, J.M.; Keller, H.; Mackie, T.R.; Olivera, G.; Soisson, E.T.

    2005-01-01

    Inherent to helical tomotherapy is a dose variation pattern that manifests as a 'ripple' (peak-to-trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering or beam divergence, an analytical posing of the problem as a simple integral predicts minima near a pitch of 1/n where n is an integer. A convolution-superposition dose calculator (TomoTherapy, Inc.) included all the physics needed to explore the ripple magnitude versus pitch and beam width. The results of the dose calculator and some benchmark measurements demonstrate that the ripple has sharp minima near p=0.86(1/n). The 0.86 factor is empirical and caused by a beam junctioning of the off-axis dose profiles which differ from the axial profiles as well as a long scatter tail of the profiles at depth. For very strong intensity modulation, the 0.86 factor may vary. The authors propose choosing particular minima pitches or using a second delivery that starts 180 deg off-phase from the first to reduce these ripples: 'Double threading'. For current typical pitches and beam widths, however, this effect is small and not clinically important for most situations. Certain extremely large field or high pitch cases, however, may benefit from mitigation of this effect

  2. Recurrent postoperative sciatica: Evaluation with MR imaging and enhanced CT

    International Nuclear Information System (INIS)

    Duoauferrier, R.; Frocrain, L.; Husson, J.L.

    1987-01-01

    The authors prospectively compared surface coil MR (SCMR) imaging and CT with iodinate contrast enhancement in 50 patients with recurrent postoperative sciatica. Of the 50 patients enrolled in the study, surgical treatment was elected in 27 patients after independent examination of SCMR imaging and enhanced CT. All predictions made with the 27 SCMR images were surgically confirmed. The surgical findings were 20 recurrent disk herniations, five recurrent disk herniations with scar tissue, one disk herniation above the level of diskectomy, and one disk herniation below the level of diskectomy. The surgical findings of the 12 patients who had scar tissue on CT were seven recurrent disk herniations, four recurrent disk herniations with scar tissue, and one disk herniation below the operated level. SCMR imaging was more sensitive and more specific than CT to differentiate scar tissue from recurrent disk herniation

  3. Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT

    International Nuclear Information System (INIS)

    Knobloch, Gesine; Hamm, Bernd; Jost, Gregor; Pietsch, Hubertus; Huppertz, Alexander

    2014-01-01

    The potential diagnostic value of dual-energy computed tomography (DE-CT) compared to dynamic contrast-enhanced CT (DCE-CT) and conventional contrast-enhanced CT (CE-CT) in the assessment of early regorafenib treatment effects was evaluated in a preclinical setting. A rat GS9L glioma model was examined with contrast-enhanced dynamic DE-CT measurements (80 kV/140 kV) for 4 min before and on days 1 and 4 after the start of daily regorafenib or placebo treatment. Tumour time-density curves (0-240 s, 80 kV), DE-CT (60 s) derived iodine maps and the DCE-CT (0-30 s, 80 kV) based parameters blood flow (BF), blood volume (BV) and permeability (PMB) were calculated and compared to conventional CE-CT (60 s, 80 kV). The regorafenib group showed a marked decrease in the tumour time-density curve, a significantly lower iodine concentration and a significantly lower PMB on day 1 and 4 compared to baseline, which was not observed for the placebo group. CE-CT showed a significant decrease in tumour density on day 4 but not on day 1. The DE-CT-derived iodine concentrations correlated with PMB and BV but not with BF. DE-CT allows early treatment monitoring, which correlates with DCE-CT. Superior performance was observed compared to single-energy CE-CT. circle Regorafenib treatment response was evaluated by CT in a rat tumour model. (orig.)

  4. Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Knobloch, Gesine; Hamm, Bernd [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Jost, Gregor; Pietsch, Hubertus [Bayer Healthcare, MR and CT Contrast Media Research, Berlin (Germany); Huppertz, Alexander [Imaging Science Institute Charite - Siemens, Berlin (Germany)

    2014-08-15

    The potential diagnostic value of dual-energy computed tomography (DE-CT) compared to dynamic contrast-enhanced CT (DCE-CT) and conventional contrast-enhanced CT (CE-CT) in the assessment of early regorafenib treatment effects was evaluated in a preclinical setting. A rat GS9L glioma model was examined with contrast-enhanced dynamic DE-CT measurements (80 kV/140 kV) for 4 min before and on days 1 and 4 after the start of daily regorafenib or placebo treatment. Tumour time-density curves (0-240 s, 80 kV), DE-CT (60 s) derived iodine maps and the DCE-CT (0-30 s, 80 kV) based parameters blood flow (BF), blood volume (BV) and permeability (PMB) were calculated and compared to conventional CE-CT (60 s, 80 kV). The regorafenib group showed a marked decrease in the tumour time-density curve, a significantly lower iodine concentration and a significantly lower PMB on day 1 and 4 compared to baseline, which was not observed for the placebo group. CE-CT showed a significant decrease in tumour density on day 4 but not on day 1. The DE-CT-derived iodine concentrations correlated with PMB and BV but not with BF. DE-CT allows early treatment monitoring, which correlates with DCE-CT. Superior performance was observed compared to single-energy CE-CT. circle Regorafenib treatment response was evaluated by CT in a rat tumour model. (orig.)

  5. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  6. Dental-CT: image quality and absorbed radiation dose of different scan protocols

    International Nuclear Information System (INIS)

    Schorn, C.; Alamo, L.; Funke, M.; Grabbe, E.; Visser, H.; Hermann, K.P.

    1999-01-01

    Purpose: To develop a scan protocol for dental-CT which guarantees good image quality at the lowest possible radiation dose. Methods: In an experimental investigation Dental-CT (HSA, GE, Milwaukee, USA) of the mandible of two human skeletons positioned in a water tank were performed in order to define the most advantageous scan protocol. Tube currents ranged from 40 to 200 mA and the scan technique was modified (axial mode or helical mode with pitches of 1 to 3 and corresponding increments of 0.4 to 1.0 mm). 39 patients underwent a dental-CT with decreased current (80 mA) in the helical scan mode (pitch 2, slice thickness 1 mm). Dose measurements were performed for two different scan protocols (A: axial, 130 mAs, B: helical, 80 mA, pitch 2). Results: The preliminary investigations of image quality showed only a minor effect of the applied current. For the helical scan mode, pitches of more than 2 impaired image quality. A low increment had no advantages. There were no disadvantages in clinical practice using protocol B with decreased tube current. Absorbed radiation dose of dental CT performed with protocol B was decreased to one third in comparison to protocol A. Conclusions: A scan protocol with a low tube current (e.g., 80 mA, for a rotation time of 1 s) and a helical scan mode (e.g., for a slice thickness of 1 mm with a pitch of 2 and an increment of 1 mm) is recommended for performing dental-CT. (orig.) [de

  7. Dual phase helical CT versus portal venous phase CT for the detection of colorectal liver metastases: Correlation with intra-operative sonography, surgical and pathological findings

    International Nuclear Information System (INIS)

    Scott, D. John; Guthrie, J. Ashley; Arnold, Paul; Ward, Janice; Atchley, Julian; Wilson, Daniel; Robinson, Philip J.

    2001-01-01

    AIM: To assess whether dual phase helical computed tomography (DPCT) of the liver improves the detection of colorectal liver metastases compared with portal venous phase (PVP) imaging alone. MATERIALS AND METHODS: DPCT was performed in 33 consecutive patients before laparotomy for resection of colorectal liver metastases. CT comprised 8-mm slice collimation with a pitch of 1 to 1.25; imaging was commenced 20-25 and 65-70 s after the start of injection of 150 ml of contrast medium at 5 ml/s to coincide with hepatic arterial phase (HAP) and PVP contrast enhancement, respectively. Four blinded observers independently reviewed the HAP, PVP and DPCT images recording the site and size of all lesions. Alternative-free response receiver operating characteristic (AFROC) methodology was used to analyse the results, which were correlated with surgery, intra-operative ultrasound and histology. RESULTS: The mean observer sensitivities for malignant lesion detection were 75.3% for DPCT, 69.7% for PVP imaging and 66.7% for HAP imaging alone. There was a statistically significant improvement in malignant lesion detection using DPCT when compared with PVP imaging alone (P < 0.05). The mean areas under the AFROC curves were 0.84 for DPCT and 0.82 for PVP (P < 0.03) imaging alone. CONCLUSION: The detection of colorectal liver metastases was marginally better with DPCT than with PVP imaging alone, but the discovery of additional lesions did not affect the management of any of the patients in this study. Scott, D.J. et al. (2001)

  8. Hepatic and pancreatic involvement in hereditary hemorrhagic telangiectasia: quantitative and qualitative evaluation with 64-section CT in asymptomatic adult patients

    Energy Technology Data Exchange (ETDEWEB)

    Barral, Matthias; Sirol, Marc; Hamzi, Lounis; Gayat, Etienne; Boudiaf, Mourad [Hopital Lariboisiere-APHP, Department of Abdominal Imaging, Paris (France); Place, Vinciane [Hopital Lariboisiere-APHP, Department of Abdominal Imaging, Paris (France); Universite Diderot-Paris 7, UFR de Medecine, Paris (France); Borsik, Michel [Hopital Lariboisiere-APHP, Deparment of Ear, Nose and Throat, Paris (France); Soyer, Philippe [Hopital Lariboisiere-APHP, Department of Abdominal Imaging, Paris (France); Universite Diderot-Paris 7, UFR de Medecine, Paris (France); Unite 965 INSERM/Paris7, Hopital Lariboisiere-APHP, Paris (France)

    2012-01-15

    To analyse quantitatively and qualitatively asymptomatic hepatic and pancreatic involvement in hereditary haemorrhagic telangiectasia (HHT) using 64-section helical CT. The 64-section helical CT examinations of 19 patients with HHT (8 men, 11 women; mean age, 58.6 years) were quantitatively and qualitatively analysed and compared to those of 19 control subjects who were matched for age and sex. Comparisons were made using univariate analysis. Dilated and tortuous intrahepatic arterial branches was the most discriminating independent variable (P < 0.0001) and had the highest specificity (100%; 19/19; 95%CI: 82%-100%) and accuracy (97%; 37/38; 95%CI: 86%-100%) for the diagnosis of HHT. Heterogeneous enhancement of hepatic parenchyma, intrahepatic telangiectases, hepatic artery to hepatic vein shunting, hepatic artery enlargement (i.e. diameter > 6.5 mm) and portal vein enlargement (i.e. diameter > 13 mm) were other variables that strongly correlated with the presence of HHT. Intrapancreatic telangiectases and arteriovenous malformations were found in 42% and 16% of patients with HHT, respectively. Liver and pancreatic involvement in asymptomatic HHT patients is associated with myriad suggestive findings on 64-section helical CT. It can be anticipated that familiarity with these findings would result in more confident diagnosis of HHT. (orig.)

  9. Evaluation of radiation doses delivered in different chest CT protocols

    International Nuclear Information System (INIS)

    Gorycki, Tomasz; Lasek, Iwona; Kamiński, Kamil; Studniarek, Michał

    2014-01-01

    There are differences in the reference diagnostic levels for the computed tomography (CT) of the chest as cited in different literature sources. The doses are expressed either in weighted CT dose index (CTDI VOL ) used to express the dose per slice, dose-length product (DLP), and effective dose (E). The purpose of this study was to assess the radiation dose used in Low Dose Computer Tomography (LDCT) of the chest in comparison with routine chest CT examinations as well as to compare doses delivered in low dose chest CT with chest X-ray doses. CTDI VOL and DLP doses were taken to analysis from routine CT chest examinations (64 MDCT TK LIGHT SPEED GE Medical System) performed in 202 adult patients with FBP reconstruction: 51 low dose, 106 helical, 20 angio CT, and 25 high resolution CT protocols, as well as 19 helical protocols with iterative ASIR reconstruction. The analysis of chest X-ray doses was made on the basis of reports from 44 examinations. Mean values of CTDI VOL and DLP were, respectively: 2.1 mGy and 85.1 mGy·cm, for low dose, 9.7 mGy and 392.3 mGy·cm for helical, 18.2 mGy and 813.9 mGy·cm for angio CT, 2.3 mGy and 64.4 mGy·cm for high resolution CT, 8.9 mGy. and 317.6 mGy·cm for helical ASIR protocols. Significantly lower CTDI VOL and DLP values were observed for low dose and high resolution CT versus the remaining CT protocols; doses delivered in CT ASIR protocols were also lower (80–81%). The ratio between medial doses in low dose CT and chest X-ray was 11.56. Radiation dose in extended chest LDCT with parameters allowing for identification of mediastinal structures and adrenal glands is still much lower than that in standard CT protocols. Effective doses predicted for LDCT may exceed those used in chest X-ray examinations by a factor of 4 to 12, depending on LDCT scan parameters. Our results, as well as results from other authors, suggest a possibility of reducing the dose by means of iterative reconstruction. Efforts towards further dose

  10. Percutaneous radiofrequency thermal ablation of lung VX2 tumors in a rabbit model: evaluation with helical CT findings for the complete and partal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Gong Yong; Han, Young Min; Lim, Yeong Su; Jang, Kyu Yun; Lee, Sang Yong; Chung, Gyung Ho [School of Medicine, Chonbuk National Univ., Chonju (Korea, Republic of)

    2004-05-01

    To evaluate the radiologic findings for complete and partial ablation after percutaneous CT-guided transthoracic radiofrequency ablation (RFA) of lung VX2 tumor implanted in rabbits. Thirteen rabbits with successfully implanted lung VX2 were used. Three rabbits as controls did not receive RFA while the other ten rabbits underwent RFA; 5 complete and 5 partial. RFA was performed using an internally cooled, 17-gauge electrode (Radionics, Burlington, MA) with a 1-cm active tip under CT guidance. Postprocedural CT was performed within 3 days, and we analyzed the ablated size, enhancement pattern, shape, margin, and complications of the complete and partial ablation groups. Rabbits were sacrificed after postprocedural CT with an overdose of ketamine, and pathologic findings of the ablated groups were compared with those of the control group. The size of the ablated lesions and the enhancement pattern differed between the completely and partially ablated groups on chest CT. The size of the ablated lesions was increased by 47.1% in the completely ablated group and by 2.1% in the partially ablated group. In the completely ablated group, VX2 tumor showed absolutely no enhancement, whereas only ablated pulmonary parenchyma outside VX2 showed mild enhancement on enhanced CT. In the partial ablated group, a part of VX2 became strongly enhanced on enhanced CT. On microscopic examination, the completely ablated group demonstrated that a viable tumor cell was not visible. In the partially ablated group, however, a viable tumor cell within the surrounding fibrous capsule on the peripheral area of the VX2 was observed. The important CT findings for evaluation of complete and partial RFA are the ablated size and enhancement pattern of the ablated lesion.

  11. Diagnostic value of contrast-enhanced dynamic CT in predicting the malignancy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Song, Koun Sik; Lee, Eun Hye; Kim, Ji Hoon; Lee, Jin Seong; Lim, Tae Hwan

    1997-01-01

    To determine whether the maximal enhancement time in dynamic CT is different between benign and malignant solitary pulmonary nodules (SPN)s, and to evaluate the value of densitometry on dynamic CT in predicting the malignancy of SPN. Fifty-six patients with SPN of less than 4cm in diameter as seen on chest radiograph and SPN without benign pattern of calcification or fat, as seen on pre-enhance-ment spiral CT scans were included in this study. SPN with small cavitation sufficient to measure CT density, were also included. Thirty-four SPNs were diagnosed pathologically or radiologically as 20 malignant nodules and 14 benign nodules. Dynamic CT was performed by two techniques after injection of 50ml of nonionic contrast media at the rate of 2ml/sec. In 28 patients, incremental dynamic CT was performed before and of 15 seconds, 1 minute, 2 minutes, 3 minutes, and 4 minutes after injection of contrast media during shallow respiration. In 28 patients, double spiral CT was performed 2 minutes and 3 minutes after injection of contrast media during single breath hold. CT readings were taken at the central portion of SPNs, with a circular region of interest. The degree and time of maximal enhancement were recorded. In dynamic CT the maximal enhancement time of SPNs was not significantly different between malignant (2.73±1.27 minute) and benign nodules (2.56±1.24 minute). The enhancement of malignant nodules was significantly greater (21.42±12.17 HU) than of benign nodules (5.15±5.25 HU) (p<.0001). In dynamic CT of SPNs, there is no difference in maximal enhancement time between benign and malignant nodules;enhancement of the latter is significantly greater than that of the former. Maximal enhancement greater than 15 HU can be a good predictor of malignancy of SPNs

  12. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  13. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  14. Experimental investigation of in-cylinder air flow to optimize number of helical guide vanes to enhance DI diesel engine performance using mamey sapote biodiesel

    Science.gov (United States)

    Kumar, A. Raj; Janardhana Raju, G.; Hemachandra Reddy, K.

    2018-03-01

    The current research work investigates the influence of helical guide vanes in to the intake runner of a D.I diesel engine operating by the high viscous Mamey Sapote biodiesel to enhance in-cylinder suction air flow features. Helical guide vanes of different number of vanes are produced from 3D printing and placed in the intake manifold to examine the air flow characteristics. Four different helical guide vane devices namely 3, 4, 5 and 6 vanes of the same dimensions are tested in a D.I diesel engine operating with Mamey Sapote biodiesel blend. As per the experimental results of engine performance and emission characteristics, it is found that 5 vanes helical guide vane swirl device exhibited in addition number of increased improvements such as the brake power and bake thermal efficiency by 2.4% and 8.63% respectively and the HC, NOx, Carbon monoxide and, Smoke densities are reduced by 15.62%, 4.23%, 14.27% and 9.6% at peak load operating conditions as collate with normal engine at the same load. Hence this investigation concluded that Helical Guide Vane Devices successfully enhanced the in-cylinder air flow to improve better addition of Mamey Sapote biodiesel with air leading in better performance of the engine than without vanes.

  15. CT urography of urinary diversions with enhanced CT digital radiography: preliminary experience.

    Science.gov (United States)

    Sudakoff, Gary S; Guralnick, Michael; Langenstroer, Peter; Foley, W Dennis; Cihlar, Krista L; Shakespear, Jonathan S; See, William A

    2005-01-01

    The purpose of this study was to determine if 3D-rendered CT urography (CTU) depicts both normal and abnormal findings in patients with urinary diversions and if the addition of contrast-enhanced CT digital radiography (CTDR) improves opacification of the urinary collecting system. Thirty CTU and contrast-enhanced CTDR examinations were performed in 24 patients who underwent cystectomy for bladder cancer. Indications for evaluation included hematuria, tumor surveillance, or suspected diversion malfunction. All examinations were evaluated without knowledge of the stage or grade of a patient's tumor and were compared with the clinical records. Opacification of the urinary collecting system was evaluated with 3D CTU alone, contrast-enhanced CTDR alone, and combined CTU and CTDR. Nine abnormalities were identified including distal ureteral strictures (n = 4), vascular compression of the mid left ureter (n = 1), scarring of the mid right pole infundibulum (n = 1), bilateral hydronephrosis and hydroureter (n = 1), urinary reservoir calculus (n = 1), and tumor recurrence invading the afferent limb of the neobladder (n = 1). Eight of the nine detected abnormalities were surgically or pathologically confirmed. All abnormalities were identified on all three imaging techniques but were best seen on 3D CTU and enhanced CTDR images. Incomplete opacification of the urinary collecting system occurred in 17 patients with CTU alone, 12 patients with contrast-enhanced CTDR alone, and nine patients with combined CTU and contrast-enhanced CTDR. Compared with CTU alone, the combined technique of 3D CTU and contrast-enhanced CTDR improved opacification by a statistically significant difference (p = 0.037). CTU with 3D rendering can accurately depict both normal and abnormal postoperative findings in patients with urinary diversions. Adding enhanced CTDR can improve visualization of the urinary collecting system.

  16. Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Coche, E.E.; Hammer, F.D.; Goffette, P.P. [Dept. of Radiology, St. Luc University Hospital, Brussels (Belgium)

    2001-11-01

    The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection. (orig.)

  17. Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT

    International Nuclear Information System (INIS)

    Coche, E.E.; Hammer, F.D.; Goffette, P.P.

    2001-01-01

    The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection. (orig.)

  18. Cardiac cone-beam CT

    International Nuclear Information System (INIS)

    Manzke, Robert

    2005-01-01

    This doctoral thesis addresses imaging of the heart with retrospectively gated helical cone-beam computed tomography (CT). A thorough review of the CT reconstruction literature is presented in combination with a historic overview of cardiac CT imaging and a brief introduction to other cardiac imaging modalities. The thesis includes a comprehensive chapter about the theory of CT reconstruction, familiarizing the reader with the problem of cone-beam reconstruction. The anatomic and dynamic properties of the heart are outlined and techniques to derive the gating information are reviewed. With the extended cardiac reconstruction (ECR) framework, a new approach is presented for the heart-rate-adaptive gated helical cardiac cone-beam CT reconstruction. Reconstruction assessment criteria such as the temporal resolution, the homogeneity in terms of the cardiac phase, and the smoothness at cycle-to-cycle transitions are developed. Several reconstruction optimization approaches are described: An approach for the heart-rate-adaptive optimization of the temporal resolution is presented. Streak artifacts at cycle-to-cycle transitions can be minimized by using an improved cardiac weighting scheme. The optimal quiescent cardiac phase for the reconstruction can be determined automatically with the motion map technique. Results for all optimization procedures applied to ECR are presented and discussed based on patient and phantom data. The ECR algorithm is analyzed for larger detector arrays of future cone-beam systems throughout an extensive simulation study based on a four-dimensional cardiac CT phantom. The results of the scientific work are summarized and an outlook proposing future directions is given. The presented thesis is available for public download at www.cardiac-ct.net

  19. Comparison of 68Ga-DOTANOC PET/CT and contrast-enhanced CT in localisation of tumours in ectopic ACTH syndrome

    Science.gov (United States)

    Jadhav, Swati S; Lila, Anurag R; Kasaliwal, Rajeev; Khare, Shruti; Yerawar, Chaitanya G; Hira, Priya; Phadke, Uday; Shah, Hina; Lele, Vikram R; Malhotra, Gaurav; Bandgar, Tushar; Shah, Nalini S

    2016-01-01

    Background Localising ectopic adrenocorticotrophic hormone (ACTH) syndrome (EAS) tumour source is challenging. Somatostatin receptor-based PET imaging has shown promising results, but the data is limited to case reports and small case series. We reviewed here the performance of 68Ga-DOTANOC positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) in our cohort of 12 consecutive EAS patients. Materials and methods Retrospective data analysis of 12 consecutive patients of EAS presenting to a single tertiary care centre in a period between January 2013 and December 2014 was done. CECT and 68Ga-DOTANOC PET/CT were reported (blinded) by an experienced radiologist and a nuclear medicine physician, respectively. The performance of CECT and 68Ga-DOTANOC PET/CT was compared. Results Tumours could be localised in 11 out of 12 patients at initial presentation (overt cases), whereas in one patient, tumour remained occult. Thirteen lesions were identified in 11 patients as EAS source (true positives). CECT localised 12 out of these 13 lesions (sensitivity 92.3%) and identified five false-positive lesions (positive predictive value (PPV) 70.5%). Compared with false-positive lesions, true-positive lesions had greater mean contrast enhancement at 60s (33.2 vs 5.6 Hounsfield units (HU)). 68Ga-DOTANOC PET/CT was able to identify 9 out of 13 lesions (sensitivity 69.2%) and reported no false-positive lesions (PPV 100%). Conclusion CECT remains the first-line investigation in localisation of EAS. The contrast enhancement pattern on CECT can further aid in characterisation of the lesions. 68Ga-DOTANOC PET/CT can be added to CECT, to enhance positive prediction of the suggestive lesions. PMID:27006371

  20. Complex cystic renal masses: characterization with contrast-enhanced US.

    Science.gov (United States)

    Ascenti, Giorgio; Mazziotti, Silvio; Zimbaro, Giovanni; Settineri, Nicola; Magno, Carlo; Melloni, Darwin; Caruso, Rosario; Scribano, Emanuele

    2007-04-01

    To prospectively compare contrast material-enhanced ultrasonography (US) with computed tomography (CT) in the classification of complex cystic renal masses with the Bosniak system. Ethics committee approval and written informed consent were obtained. Forty patients (17 women, 23 men; age range, 31-77 years) with 44 complex cystic renal masses detected with conventional US were prospectively examined by using second-harmonic US with a second-generation contrast agent and multiphasic helical CT. Thirty-six patients had one lesion, and four patients had two lesions. Surgical resection in nine patients and imaging follow-up in 31 patients were used to determine the outcome. On contrast-enhanced US images, masses were classified as Bosniak category II (n = 18), IIF (ie, lesions were classified as category II and follow-up was needed) (n = 16), III (n = 7), or IV (n = 3) lesions. On CT images, masses were classified as Bosniak category II (n = 24), IIF (n = 10), III (n = 7), or IV (n = 3) lesions. Interobserver agreement was high (kappa = 0.86, P < .001) for classification with US. Complete concordance between the readers was found for classification with CT. Complete concordance between contrast-enhanced US and CT was observed in the differentiation of surgical and nonsurgical complex cysts. Complete concordance among the three readers in the assessment of vascularity with contrast-enhanced US was found. Interobserver agreement in the evaluation of enhancement on CT images was high (kappa = 0.88, P < .001). Concordance between contrast-enhanced US and CT in the evaluation of vascularization was high (kappa = 0.77, P < .001). The study data suggest that contrast-enhanced second-harmonic US is appropriate for renal cyst classification with the Bosniak system.

  1. The relationship between microvessels density and CT enhancement of the peripheral lung cancer

    International Nuclear Information System (INIS)

    Liu Shiyuan; Zhou Kangrong; Xiao Xiangsheng; Ye Tingjun; Zhang Zhiyong

    1999-01-01

    Objective: To investigate the relationship between microvessel density (MVD), clinical prognosis and CT enhancement of the peripheral lung cancer. Methods: 127 cases of peripheral lung cancer were examined with CT (87 cases retrospectively and 40 cases prospectively), and MVD were measured with immunohistochemical method by factor VIII on the specimens of the resected tumors. The results were analyzed and compared with CT enhancement, metastasis and prognosis. Results: The MVD was higher in the peripheral junction zone and interstitial areas than that in the parenchymal areas and necrotic zones of the tumors. Patients with nodal metastasis had higher MVD than those without nodal metastasis (56.9 +- 18.1 versus 43.8 +- 23.6, P 0.05); but the enhancement of the lung cancer correlated well with MVD (r 0.8874). Conclusions: Measurement of the microvessel density of tumor can determine the degree of angiogenesis of neoplasm and predict the metastasis or prognosis of the lung cancer. Angiogenesis not only constitutes the basis of enhancement of the tumor, but also determine the various degrees and patterns of enhancement. Spiral dynamic CT is the technique ideal to demonstrate the enhancement features, which might be helpful in making differential diagnosis of pulmonary nodules

  2. Cervical lymph node metastasis of oral squamous cell carcinomas. CT enhancement and histopathological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Etoh, Yohei; Kimura, Takuji; Sasaki, Akira; Kishimoto, Koji; Matsumura, Tomohiro; Kishi, Kanji [Okayama Univ. (Japan). Dental School

    2000-06-01

    A comparison of the results of histopathological and enhanced CT examinations were carried out for 88 patients with oral squamous cell carcinomas who underwent neck dissection. CT scanning (5-mm thick section) images obtained during bolus/drip injection of Iopamidol were routinely taken through the neck. Ninety-two of 1634 nodes were histologically diagnosed as metastatic. Low density areas surrounding enhancement rims were metastatic nodal central necrosis or keratinization. Enhanced areas in many metastatic nodes were considered to be lymphatic architecture, not metastatic masses especially in the avascular keratinization. Enhanced CT produced accurate information of lymph node size, location, shape, grouping and spread from nodes to adjacent structures. However, it was considered that not every metastatic lymph node should show enlargement and/or enhancement. Improved assessment of solid metastatic features of lymph nodes (shape, size, and involvement) may be achieved with the aid of thin-thickness CT. (author)

  3. Cervical lymph node metastasis of oral squamous cell carcinomas. CT enhancement and histopathological evaluations

    International Nuclear Information System (INIS)

    Etoh, Yohei; Kimura, Takuji; Sasaki, Akira; Kishimoto, Koji; Matsumura, Tomohiro; Kishi, Kanji

    2000-01-01

    A comparison of the results of histopathological and enhanced CT examinations were carried out for 88 patients with oral squamous cell carcinomas who underwent neck dissection. CT scanning (5-mm thick section) images obtained during bolus/drip injection of Iopamidol were routinely taken through the neck. Ninety-two of 1634 nodes were histologically diagnosed as metastatic. Low density areas surrounding enhancement rims were metastatic nodal central necrosis or keratinization. Enhanced areas in many metastatic nodes were considered to be lymphatic architecture, not metastatic masses especially in the avascular keratinization. Enhanced CT produced accurate information of lymph node size, location, shape, grouping and spread from nodes to adjacent structures. However, it was considered that not every metastatic lymph node should show enlargement and/or enhancement. Improved assessment of solid metastatic features of lymph nodes (shape, size, and involvement) may be achieved with the aid of thin-thickness CT. (author)

  4. Application of low dose multi-slice helical CT in orbital trauma patients

    International Nuclear Information System (INIS)

    Yang Rui; Dai Limei; Li Jianying; Wang Fengyan; Du Guoquan

    2010-01-01

    Objective: To investigate the most appropriate low radiation dose in multi-slice CT (MSCT) scans for orbital trauma patients. Methods: Thirty trauma patients with suspected orbital fractures who underwent helical CT scans with a 64-MSCT using regular dose were selected. Noise was artificially introduced to the axial images using an image space noise addition tool to simulate 6 sets of lower dose scans with tube current of 30, 70, 100, 140, 170 and 200 mA, respectively. The lowest tube current with adequate image quality for confident diagnosis was determined based on the evaluation of the overall image quality and fracture detection on images at different dose levels. The determined lowest tube current was then validated using clinical scans. Radiation dose related parameters CTDIvol, DLP, ED were also recorded. Image quality was evaluated according to its low-density resolution, noise and structure clarity and characterized into 5-grades of excellent, good, fair, worse and worst. Rank sum test and χ 2 test were used for statistics. Results: In 30 trauma patients with regular dose of 300 mA, there were 30 cases of orbital fracture, 19 cases of intraorbital emphysema, 12 cases of ocular muscle injury and 1 case of intraorbital foreign body. These changes could still be clearly observed and correctly diagnosed when the tube current was reduced to as low as 70 mA. However, the overall image quality was mostly fair. At the simulated dose of 100 mA, the majority of images were characterized as excellent or good, and there was no statistical difference compared with that of regular dose scans (P>0.05). In the clinical evaluation for 20 orbital trauma patients with the reduced tube current of 100 m A , the majority of images were judged to be excellent (9 cases) or good (17 cases) and fair (4 cases). The radiation dose (0.29 mSv) was reduced by 70% compared with that of regular tube current of 300 mA (0.86 mSv). Conclusion: The tube current of MSCT may be used as low as

  5. Three-dimensional multislice CT imaging of otitis media

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro; Wada, Akihiro; Ando, Ichiro

    2002-01-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  6. Three-dimensional multislice CT imaging of otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Miyako [Yanagibasi Hospital, Tokyo (Japan); Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro [Juntendo Univ., Tokyo (Japan). School of Medicine; Wada, Akihiro; Ando, Ichiro [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2002-07-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  7. ICRF heating on helical devices

    International Nuclear Information System (INIS)

    Rasmussen, D.A.; Lyon, J.F.; Hoffman, D.J.; Murakami, M.; England, A.C.; Wilgen, J.B.; Jaeger, E.F.; Wang, C.; Batchelor, D.B.

    1995-01-01

    Ion cyclotron range of frequency (ICRF) heating is currently in use on CHS and W7-AS and is a major element of the heating planned for steady state helical devices. In helical devices, the lack of a toroidal current eliminates both disruptions and the need for ICRF current drive, simplifying the design of antenna structures as compared to tokamak applications. However the survivability of plasma facing components and steady state cooling issues are directly applicable to tokamak devices. Results from LHD steady state experiments should be available on a time scale to strongly influence the next generation of steady state tokamak experiments. The helical plasma geometry provides challenges not faced with tokamak ICRF heating, including the potential for enhanced fast ion losses, impurity accumulation, limited access for antenna structures, and open magnetic field lines in the plasma edge. The present results and near term plans provide the basis for steady state ICRF heating of larger helical devices. An approach which includes direct electron, mode conversion, ion minority and ion Bernstein wave heating addresses these issues

  8. ICRF heating on helical devices

    International Nuclear Information System (INIS)

    Rasmussen, D.A.; Lyon, J.F.; Hoffman, D.J.

    1995-01-01

    Ion cyclotron range of frequency (ICRF) heating is currently in use on CHS and W7AS and is a major element of the heating planned for steady state helical devices. In helical devices, the lack of a toroidal current eliminates both disruptions and the need for ICRF current drive, simplifying the design of antenna structures as compared to tokamak applications. However the survivability of plasma facing components and steady state cooling issues are directly applicable to tokamak devices. Results from LHD steady state experiments should be available on a time scale to strongly influence the next generation of steady state tokamak experiments. The helical plasma geometry provides challenges not faced with tokamak ICRF heating, including the potential for enhanced fast ion losses, impurity accumulation, limited access for antenna structures, and open magnetic field lines in the plasma edge. The present results and near term plans provide the basis for steady state ICRF heating of larger helical devices. An approach which includes direct electron, mode conversion, ion minority and ion Bernstein wave heating addresses these issues

  9. Semi-quantitative assessment of tricuspid regurgitation on contrast-enhanced multidetector CT

    International Nuclear Information System (INIS)

    Groves, A.M.; Win, T.; Charman, S.C.; Wisbey, C.; Pepke-Zaba, J.; Coulden, R.A.

    2004-01-01

    AIM: To assess whether the early regurgitation of intravenous contrast medium into the inferior vena cava (IVC) and/or hepatic veins on computed tomography (CT), indicates tricuspid regurgitation (TR), and if so, whether it be used to grade severity. MATERIALS AND METHODS: We identified 86 consecutive patients that had been investigated for possible pulmonary endarterectomy at Papworth Hospital. From these, 61 patients were selected in whom CT, transthoracic echocardiography, and right heart catheterization (RHC) had been performed within 6 weeks. Using an arbitrary visual scale, the degree of TR assessed by intravenous contrast-enhanced CT was compared with echocardiography. Results were analysed using a kappa weighted statistical test. In addition, CT and echocardiographic assessments of TR severity were correlated with pulmonary artery pressure measurements obtained by RHC (Spearman's rank correlation coefficient). RESULTS: CT assessment of TR had a sensitivity of 90.4% and a specificity of 100% in detecting echocardiographic TR. For TR graded as more than trivial by echocardiography, sensitivity of CT was 100%. With respect to RHC data, the correlation between severity assessment of TR between CT and echocardiography using the Kappa weighted coefficient was 0.56 (moderately good agreement). With respect to RHC data, the correlation between mean pulmonary pressure and TR grading on CT and echocardiography was r=0.685 (p<0.001) and r=0.727 (p<0.001), respectively. CONCLUSION: Early opacification of the IVC or hepatic veins on first-pass contrast-enhanced CT almost invariably indicates TR. There is moderately good agreement between CT and echocardiographic assessment of the severity of TR. Both CT and echocardiographic grading of TR correlate well with RHC measurements of pulmonary artery pressure

  10. Comparison of Xenon-Enhanced Area-Detector CT and Krypton Ventilation SPECT/CT for Assessment of Pulmonary Functional Loss and Disease Severity in Smokers.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Takenaka, Daisuke; Kaminaga, Shigeo; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi

    2018-02-01

    The objective of this study was to compare the capability of xenon-enhanced area-detector CT (ADCT) performed with a subtraction technique and coregistered 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity in smokers. Forty-six consecutive smokers (32 men and 14 women; mean age, 67.0 years) underwent prospective unenhanced and xenon-enhanced ADCT, 81m Kr-ventilation SPECT/CT, and pulmonary function tests. Disease severity was evaluated according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification. CT-based functional lung volume (FLV), the percentage of wall area to total airway area (WA%), and ventilated FLV on xenon-enhanced ADCT and SPECT/CT were calculated for each smoker. All indexes were correlated with percentage of forced expiratory volume in 1 second (%FEV 1 ) using step-wise regression analyses, and univariate and multivariate logistic regression analyses were performed. In addition, the diagnostic accuracy of the proposed model was compared with that of each radiologic index by means of McNemar analysis. Multivariate logistic regression showed that %FEV 1 was significantly affected (r = 0.77, r 2 = 0.59) by two factors: the first factor, ventilated FLV on xenon-enhanced ADCT (p < 0.0001); and the second factor, WA% (p = 0.004). Univariate logistic regression analyses indicated that all indexes significantly affected GOLD classification (p < 0.05). Multivariate logistic regression analyses revealed that ventilated FLV on xenon-enhanced ADCT and CT-based FLV significantly influenced GOLD classification (p < 0.0001). The diagnostic accuracy of the proposed model was significantly higher than that of ventilated FLV on SPECT/CT (p = 0.03) and WA% (p = 0.008). Xenon-enhanced ADCT is more effective than 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity.

  11. Ring-enhancement pattern on contrast-enhanced CT predicts adenosquamous carcinoma of the pancreas: a matched case-control study.

    Science.gov (United States)

    Imaoka, Hiroshi; Shimizu, Yasuhiro; Mizuno, Nobumasa; Hara, Kazuo; Hijioka, Susumu; Tajika, Masahiro; Tanaka, Tsutomu; Ishihara, Makoto; Ogura, Takeshi; Obayashi, Tomohiko; Shinagawa, Akihide; Sakaguchi, Masafumi; Yamaura, Hidekazu; Kato, Mina; Niwa, Yasumasa; Yamao, Kenji

    2014-01-01

    Adenosquamous carcinoma of the pancreas (ASC) is a rare malignant neoplasm of the pancreas, exhibiting both glandular and squamous differentiation. However, little is known about its imaging features. This study examined the imaging features of pancreatic ASC. We evaluated images of contrast-enhanced computed tomography (CT) and endoscopic ultrasonography (EUS). As controls, solid pancreatic neoplasms matched in a 2:1 ratio to ASC cases for age, sex and tumor location were also evaluated. Twenty-three ASC cases were examined, and 46 solid pancreatic neoplasms (43 pancreatic ductal adenocarcinomas, two pancreatic neuroendocrine tumors and one acinar cell carcinoma) were matched as controls. Univariate analysis demonstrated significant differences in the outline and vascularity of tumors on contrast-enhanced CT in the ASC and control groups (P outline, cystic changes, and the ring-enhancement pattern on contrast-enhanced CT were seen to have significant predictive powers by stepwise forward logistic regression analysis (P = 0.044, P = 0.010, and P = 0.001, respectively). Of the three, the ring-enhancement pattern was the most useful, and its predictive diagnostic sensitivity, specificity, positive predictive value and negative predictive value for diagnosis of ASC were 65.2%, 89.6%, 75.0% and 84.3%, respectively. These results demonstrate that presence of the ring-enhancement pattern on contrast-enhanced CT is the most useful predictive factor for ASC. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  12. Recent helicity source and power supply improvements in CTX

    International Nuclear Information System (INIS)

    Henins, I.; Knox, S.O.; Jarboe, T.R.; Barnes, C.W.

    1985-01-01

    Since the last CT Symposium, two major changes in CTX have been the introduction of pulse forming networks (PFNs) to drive the coaxial electrode helicity source, and the very recent installation of a larger source with electrode diameters about twice of the previous ones. The power supplies used for CTX have ranged from the simple connection of the capacitor bank across the electrode collector plates (slow mode) to the more sophisticated PFNs, described here, which optimize the energy transfer from the capacitor bank to the magnetic fields of the spheromak. Using the PFNs, the formation and sustainment phase to peak toroidal plasma current lasts longer (approx. =0.7 ms) than in the slow mode (approx. =0.05 ms), thus lowering the peak current that must flow through the electrode surfaces. Also, by supplying the source electrodes with both a square pulse current waveform and a quasi-steady source flux, phi/sub g/, one can generate helicity at a constant source lambda/sub g/ parameter. The use of a larger diameter helicity source will improve the energy efficiency of helicity injection and allow higher source current for the same surface current density because of the larger electrode surface area

  13. Wedge-shaped parenchymal enhancement peripheral to the hepatic hemangioma : two-phase spiral CT findings

    International Nuclear Information System (INIS)

    Kim, Kyoung Won; Kim, Tae Kyoung; Han, Joon Koo; Kim, Ah Young; Lee, Hyun Ju; Song, Chi Sung; Choi, Byung Ihn

    2000-01-01

    To determine the incidence of hepatic hemangiomas associated with wedge-shaped parenchymal enhancements adjacent to the tumors as seen on two-phase spiral CT images obtained during the hepatic arterial phase and to characterize the two-phase spiral CT findings of those hemangiomas. One hundred and eight consecutive hepatic hemangiomas in 63 patients who underwent two-phase spiral CT scanning during an 11-month period were included in this study. Two-phase spiral CT scans were obtained during the hepatic arterial phase (30-second delay) and portal venous phase (65-second delay) after injection of 120 mL of contrast material at a rate of 3 mL/sec. We evaluated the frequency with which wedge-shaped parenchymal enhancement was adjacent to the hemangiomas during the hepatic arterial phase and divided hemangiomas into two groups according to whether or not wedge-shaped parenchymal enhancement was noted (Group A and Group B). The presence of such enhancement in hemangiomas was correlated with tumor size and the grade of intratumoral enhancement. In 24 of 108 hemangiomas, wedge-shaped parenchymal enhancement adjacent to hepatic tumors was seen on two-phase CT images obtained during the hepatic arterial phase. Mean hemangioma size was 22mm in group A and 24mm in group B. There was no statistically significant relationship between lesion size and the presence of wedge-shaped parenchymal enhancement adjacent to a hemangioma. In 91.7% and 100% of tumors in Group A, and in 9.6% and 17.8% in Group B, hemangiomas showed more than 50% intratumoral enhancement during the arterial and portal venous phase, respectively. Wedge-shaped parenchymal enhancements peripheral to hepatic hemangiomas was more frequently found in tumors showing more than 50% intratumoral enhancement during these two phases (p less than 0.01). Wedge-shaped parenchymal enhancements is not uncommonly seen adjacent to hepatic hemangiomas on two-phase spiral CT images obtained during the hepatic arterial phase. A

  14. Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging

    International Nuclear Information System (INIS)

    Kooiman, Judith; Pasha, Sharif M.; Zondag, Wendy; Sijpkens, Yvo W.J.; Molen, Aart J. van der; Huisman, Menno V.; Dekkers, Olaf M.

    2012-01-01

    Purpose: Contrast induced nephropathy (CIN) is defined as a decrease in renal function following administration of contrast media. The aim of this meta-analysis was to asses the overall risk of CIN, chronic loss of kidney function and the need for renal replacement therapy (RRT) after intravenous contrast enhanced CT-scan. Secondly, we aimed to identify subgroups at increased risk for CIN. Materials and methods: A literature search in Pubmed, Medline, Embase and Cochrane databases was performed. Data extraction was carried out independently by two reviewers. Meta-analysis and meta-regression were performed using an exact likelihood approach. Results: Forty studies evaluating the incidence of CIN after CT were included. The pooled incidence of CIN was 6.4% (95% CI 5.0–8.1). The risk of RRT after CIN was low, 0.06% (95% CI 0.01–0.4). The decline in renal function persisted in 1.1% of patients (95% CI 0.6–2.1%). Patients with chronic kidney disease (odds ratio 2.26, p < 0.001) or diabetes mellitus (odds ratio 3.10, p < 0.001) were at increased risk for the development of CIN. Conclusion: CIN occurred in 6% of patients after contrast enhanced CT. In 1% of all patients undergoing contrast enhanced CT the decline in renal function persisted

  15. Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kooiman, Judith, E-mail: j.kooiman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Pasha, Sharif M., E-mail: s.m.pasha@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Zondag, Wendy, E-mail: w.zondag@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Sijpkens, Yvo W.J., E-mail: ysijpens@bronovo.nl [Department of Nephrology, Bronovo Hospital, The Hague (Netherlands); Molen, Aart J. van der, E-mail: molen@lumc.nl [Department of Radiology, LUMC, Leiden (Netherlands); Huisman, Menno V., E-mail: m.v.huisman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Dekkers, Olaf M., E-mail: o.m.dekkers@lumc.nl [Department of Clinical Epidemiology and Department of Endocrinology, LUMC, Leiden (Netherlands)

    2012-10-15

    Purpose: Contrast induced nephropathy (CIN) is defined as a decrease in renal function following administration of contrast media. The aim of this meta-analysis was to asses the overall risk of CIN, chronic loss of kidney function and the need for renal replacement therapy (RRT) after intravenous contrast enhanced CT-scan. Secondly, we aimed to identify subgroups at increased risk for CIN. Materials and methods: A literature search in Pubmed, Medline, Embase and Cochrane databases was performed. Data extraction was carried out independently by two reviewers. Meta-analysis and meta-regression were performed using an exact likelihood approach. Results: Forty studies evaluating the incidence of CIN after CT were included. The pooled incidence of CIN was 6.4% (95% CI 5.0–8.1). The risk of RRT after CIN was low, 0.06% (95% CI 0.01–0.4). The decline in renal function persisted in 1.1% of patients (95% CI 0.6–2.1%). Patients with chronic kidney disease (odds ratio 2.26, p < 0.001) or diabetes mellitus (odds ratio 3.10, p < 0.001) were at increased risk for the development of CIN. Conclusion: CIN occurred in 6% of patients after contrast enhanced CT. In 1% of all patients undergoing contrast enhanced CT the decline in renal function persisted.

  16. CT angiography. Abdominal CT using intravenous aortography for contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, J; Nakauma, Y; Egawa, J; Kawamura, M [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1980-04-01

    To obtain imaging effects close to those of abdominal aortography and investigate a technique with little invasion to patients, intravenous aortography was applied to contrast enhancement (CE) in abdominal CT, and its usefulness was discussed. Intravenous aortography could clearly visualize lesions with rich neovascularity such as hepatocellular carcinoma and renal cell carcinoma. Differing from a drip infusion method, this method has complexities in its technique that contrast medium is injected at once, blood circulation time which is represented by the time between the injection and the time when the patients feel bitterness (10 - 12 seconds) must be measured before CE, and scanning begins 2 seconds before the patients feel bitterness. However, the invasion to patients due to this method is slight, and the capacity of this method to visualize neovascularity is superior to CE by a drip infusion method. Therefore, qualitative diagnosis by CT will be improved by using this method together with a drip infusion method.

  17. Cryo-EM Structure Determination Using Segmented Helical Image Reconstruction.

    Science.gov (United States)

    Fromm, S A; Sachse, C

    2016-01-01

    Treating helices as single-particle-like segments followed by helical image reconstruction has become the method of choice for high-resolution structure determination of well-ordered helical viruses as well as flexible filaments. In this review, we will illustrate how the combination of latest hardware developments with optimized image processing routines have led to a series of near-atomic resolution structures of helical assemblies. Originally, the treatment of helices as a sequence of segments followed by Fourier-Bessel reconstruction revealed the potential to determine near-atomic resolution structures from helical specimens. In the meantime, real-space image processing of helices in a stack of single particles was developed and enabled the structure determination of specimens that resisted classical Fourier helical reconstruction and also facilitated high-resolution structure determination. Despite the progress in real-space analysis, the combination of Fourier and real-space processing is still commonly used to better estimate the symmetry parameters as the imposition of the correct helical symmetry is essential for high-resolution structure determination. Recent hardware advancement by the introduction of direct electron detectors has significantly enhanced the image quality and together with improved image processing procedures has made segmented helical reconstruction a very productive cryo-EM structure determination method. © 2016 Elsevier Inc. All rights reserved.

  18. Experience with contrast-enhanced CT in delayed traumatic intracerebral hematoma

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Shiro; Nakazawa, Shozo; Yokota, Hiroyuki; Isayama, Kazuo; Yajima, Kouzo; Otsuka, Toshibumi [Nippon Medical School, Tokyo

    1984-02-01

    During the four-and-a-half-year period from April, 1976, to September, 1980, out of 257 patients with severe head injuries graded 8 or less by the Glasgow Coma Scale in the Department of Neurosurgery and Critical Care Medicine of the Nippon Medical School, Tokyo, Japan, 33 cases showed the development of delayed traumatic intracerebral hematoma (DTICH) upon the serial computerized tomography (CT). Contrast-enhanced CT was performed in 20 cases of the 33 patients demonstrating DTICH. Among these, 8 cases (40%) indicated the development of DTICH in the lesions of cerebral contusion (a salt-and-pepper appearance in the initial plain CT) which showed a remarkable enhancement, sustaining the extravasation of the contrast medium into the contused brain tissue. The authors discuss the pathogenesis of DTICH and suggest that vasoparalysis in the cerebral contusion might be a factor in the development of DTICH in patients with servere head injuries.

  19. Diagnostic performance of Contrast-enhanced CT in Pyrrolizidine Alkaloids-induced Hepatic Sinusoidal Obstructive Syndrome

    Science.gov (United States)

    Kan, Xuefeng; Ye, Jin; Rong, Xinxin; Lu, Zhiwen; Li, Xin; Wang, Yong; Yang, Ling; Xu, Keshu; Song, Yuhu; Hou, Xiaohua

    2016-01-01

    Hepatic sinusoidal obstruction syndrome (HSOS) can be caused by pyrrolizidine alkaloids(PAs)-containing herbals. Since PAs exposure is obscure and clinical presentation of HSOS is unspecific, it is challenge to establish the diagnosis of PAs-induced HSOS. Gynura segetum is one of the most wide-use herbals containing PAs. The aim of our study is to describe the features of contrast-enhanced computed tomography (CT) in gynura segetum-induced HSOS, and then determine diagnostic performance of radiological signs. We retrospectively analyzed medical records and CT images of HSOS patients (71 cases) and the controls (222 cases) enrolled from January 1, 2008, to Oct 31, 2015. The common findings of contrast CT in PAs-induced HSOS included: ascites (100%), hepatomegaly (78.87%), gallbladder wall thickening (86.96%), pleural effusion (70.42%), hepatic vein narrowing (87.32%), patchy liver enhancement (92.96%), and heterogeneous hypoattenuation (100%); of these signs, patchy enhancement and heterogeneous hypoattenuation were valuable features. Then, the result of diagnostic performance demonstrated that contrast CT possessed better performance in diagnosing PAs-induced HSOS compared with various parameters of Seattle criteria. In conclusion, the patients with PAs-induced HSOS display distinct radiologic features at CT-scan, which reveals that contrast-enhanced CT provides an effective noninvasive method for diagnosing PAs-induced HSOS. PMID:27897243

  20. Evaluation of salmon calcitonin (sCT) enteric-coated capsule for enhanced absorption and GI tolerability in rats.

    Science.gov (United States)

    Wu, Lei; Zhang, Ge; Lu, Qin; Sun, Qian; Wang, Mulan; Li, Na; Gao, Zidong; Sun, Ya; Li, Tingting; Han, Deen; Yu, Xue; Wang, Lei; Sun, Wei; Zhao, Di; Wu, Yaning; Lu, Yang; Chen, Xijing

    2010-03-01

    Considering the chronic and repeated nature of salmon calcitonin (sCT) therapy, the oral route is a preferred route of administration. But, the oral bioavailability of sCT is very low due to enzymatic degradation and poor permeation across intestinal epithelial cells. It was the aim of this study to investigate the pharmacodynamic (PD), pharmacokinetic (PK), and mucosal injury characteristic of sCT oral delivery system. In this study, PD experiments were performed to find a suitable releasing region of sCT, an effect absorption enhancer, and an optimal mass ratio of sCT/enhancer. In addition, the PK experiments were designed to validate the absorption enhancement of this oral delivery system. Histopathological evaluations on the intestinal mucosa were carried out to assess any potential toxicity of the absorption enhancer. Through the PD research, we determined that oral sCT enteric-coated capsules containing sCT and citric acid (CA) with a ratio of 1:20 may be an adaptable delivery. PK study further proved that the oral absorption of sCT was enhanced from this delivery system. Finally, no damage on intestinal mucosa was observed when rats received the delivery system containing CA for up to 7 days. These results suggested that enteric-coated capsules with a certain amount of CA might give enhanced oral delivery of peptide drugs like sCT.

  1. Comparison of excretory phase, helical computed tomography with intravenous urography in patients with painless haematuria

    International Nuclear Information System (INIS)

    O'Malley, M.E.; Hahn, P.F.; Yoder, I.C.; Gazelle, G.S.; McGovern, F.J.; Mueller, P.R.

    2003-01-01

    AIM: To compare excretory phase, helical computed tomography (CT) with intravenous (IV) urography for evaluation of the urinary tract in patients with painless haematuria. MATERIALS AND METHODS: Ninety-one out-patients had IV urography followed by helical CT limited to the urinary tract. Both IV urograms and CT images were evaluated for abnormalities of the urinary tract in a blinded, prospective manner. The clinical significance of abnormalities was scored subjectively and receiver operator characteristic curve analysis was performed. RESULTS: In 69 of 91 patients (76%), no cause of haematuria was identified. In 22 of 91 patients (24%), the cause of haematuria was identified as follows: transitional cell cancer of the bladder (n=15), urinary tract stones (n=3), cystitis (n=2), haemorrhagic pyelitis (n=1) and benign ureteral stricture (n=1). With IV urography, there were 15 true-positive, seven false-negative and three false-positive interpretations. With CT, there were 18 true-positive, four false-negative and two false-positive interpretations. There was no significant difference between IV and CT urography for the significance of the positive interpretations (n=0.47). CONCLUSION: Excretory phase CT urography was comparable with IV urography for evaluation of the urinary tract in patients with painless haematuria. However, the study population did not include any upper tract cancers. O'Malley M. E. et al. (2003). Clinical Radiology 58, 294-300

  2. Optimization of pediatric examinations in a multislice helical CT

    International Nuclear Information System (INIS)

    Ombada, T. H. A.

    2010-12-01

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI v ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI v ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  3. Optimization of pediatric examinations in a multislice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Ombada, T H. A. [Atomic Energy Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)

    2010-12-15

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI{sub v}ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI{sub v}ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  4. FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

    Directory of Open Access Journals (Sweden)

    Canh Nguyen

    2015-01-01

    Full Text Available Objective(s: In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT, complicating hepatocellular carcinoma (HCC in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT, which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%. PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001. FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001. PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6% had no extrahepatic metastasis, 3 cases (33.3% had metastasis of regional lymph nodes, and 1 case (11.1% presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are

  5. Heat Transfer Enhancement Studies in a Circular Tube Fitted with Right-Left Helical Inserts with Spacer

    OpenAIRE

    P. K. Nagarajan; P. Sivashanmugam

    2011-01-01

    Experimental investigation of heat transfer and friction factor characteristics of circular tube fitted with 300 right-left helical screw inserts with 100 mm spacer of different twist ratio has been presented for laminar and turbulent flow.. The experimental data obtained were compared with those obtained from plain tube published data. The heat transfer coefficient enhancement for 300 RL inserts with 100 mm spacer is quite comparable with for 300 R-L inserts. Performance evalu...

  6. Prospective evaluation of MRI, 11C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    International Nuclear Information System (INIS)

    Vargas, H.A.; Akin, O.; Schöder, H.; Olgac, S.; Dalbagni, G.; Hricak, H.; Bochner, B.H.

    2012-01-01

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), 11 C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, 11 C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, 11 C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, 11 C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  7. Development of impurity seeding and radiation enhancement in the helical divertor of LHD

    International Nuclear Information System (INIS)

    Mukai, K.; Masuzaki, S.; Peterson, B.J.

    2014-10-01

    Impurity seeding for the reduction of the divertor heat load was conducted in the Large Helical Device (LHD) using neon (Ne) and krypton (Kr) puffing. Enhanced radiation loss and reduction of the divertor heat load were observed without significant changes in stored energy and line averaged density. In the LHD, the radiated power fraction of the heating power, P rad /P heating , where P rad and P heating are the total radiation power and the heating power, respectively, is limited up to around 30% in hydrogen plasmas even for high density plasma just below the radiative collapse (n e,bar > 1 × 10 20 m -3 ), where n e,bar is the line averaged density. With Ne seeding, the ratio could be raised to 52% in spite of much lower density (n e,bar ∼ 1.3 × 10 19 m -3 ), albeit with a slight reduction in confinement. P rad /P heating ∼ 30% could be sustained for 3.4 s using multi-pulse Ne seeding in relatively high density plasmas in this study (n e,bar ∼ 4 × 10 19 m -3 ). Radiation profile measurement with an InfraRed Imaging Video Bolometer (IRVB) was conducted during Ne seeding. The localized supplemental radiation was observed along the helical divertor X-points (HDXs). The enhanced radiation structure was similar to the Ne radiation profile estimated by EMC3-EIRENE code. Kr seeding was also conducted to the plasma of n e,bar ∼ 3.1 × 10 19 m -3 . P rad /P heating ∼ 25% was obtained without significant change in stored energy. The enhancement of the plasma radiation has a slower time constant compared with the Ne seeding. The supplemental radiation area of the Kr seeded plasma moved from the HDXs to the core plasma. High-valent Kr ions are considered to be the dominant radiators from the plasma core region. (author)

  8. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  9. Experience with contrast-enhanced CT in delayed traumatic intracerebral hematoma

    International Nuclear Information System (INIS)

    Kobayashi, Shiro; Nakazawa, Shozo; Yokota, Hiroyuki; Isayama, Kazuo; Yajima, Kouzo; Otsuka, Toshibumi

    1984-01-01

    During the four-and-a-half-year period from April, 1976, to September, 1980, out of 257 patients with severe head injuries graded 8 or less by the Glasgow Coma Scale in the Department of Neurosurgery and Critical Care Medicine of the Nippon Medical School, Tokyo, Japan, 33 cases showed the development of delayed traumatic intracerebral hematoma (DTICH) upon the serial computerized tomography (CT). Contrast-enhanced CT was performed in 20 cases of the 33 patients demonstrating DTICH. Among these, 8 cases (40%) indicated the development of DTICH in the lesions of cerebral contusion (a salt-and-pepper appearance in the initial plain CT) which showed a remarkable enhancement, sustaining the extravasation of the contrast medium into the contused brain tissue. The authors discuss the pathogenesis of DTICH and suggest that vasoparalysis in the cerebral contusion might be a factor in the development of DTICH in patients with servere head injuries. (author)

  10. Resolution enhancement of lung 4D-CT via group-sparsity

    International Nuclear Information System (INIS)

    Bhavsar, Arnav; Wu, Guorong; Shen, Dinggang; Lian, Jun

    2013-01-01

    Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as

  11. Helicity content and tokamak applications of helicity

    International Nuclear Information System (INIS)

    Boozer, A.H.

    1986-05-01

    Magnetic helicity is approximately conserved by the turbulence associated with resistive instabilities of plasmas. To generalize the application of the concept of helicity, the helicity content of an arbitrary bounded region of space will be defined. The definition has the virtues that both the helicity content and its time derivative have simple expressions in terms of the poloidal and toroidal magnetic fluxes, the average toroidal loop voltage and the electric potential on the bounding surface, and the volume integral of E-B. The application of the helicity concept to tokamak plasmas is illustrated by a discussion of so-called MHD current drive, an example of a stable tokamak q profile with q less than one in the center, and a discussion of the possibility of a natural steady-state tokamak due to the bootstrap current coupling to tearing instabilities

  12. Three dimensional CT of stapes. Stapedial imagings in dry temporal bone and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Edamatsu, Hideo; Kubota, Osamu; Yamashita, Koichi [Kanazawa Medical Univ., Ishikawa (Japan)

    1995-03-01

    This study was performed to evaluate the usefulness and limitations of three dimensional (3-D) imagings of stapes in the middle ear by high speed helical CT. One dissected human temporal bone, ten normal and diseased ears were scanned with a slice of 1.0 mm and reconstructed in a thickness of 0.2-0.5 mm. Every specimen of 3-D can be observed in any plane and from any direction. Ossicular imagings of the temporal bone in 3-D were reconstructed as if the malleus, incus and stapes were observed under microscope. The whole structure of stapes was impossible to be represented by two dimensional CT heretofore in use, but 3-D in our study showed the head, crus and foot plate of the stapes in detail. Stapedial imagings of 3-D CT in normal ears showed the same findings as those recorded in temporal bone. Preoperative diagnostic findings of ossicles in the affected ears were very useful. Especially in ossicular anomalies, 3-D CT was positive in diagnosis and its accuracies were confirmed with operative observation. For the postoperative evaluation concerning the ossicular reconstruction, i.e. TORP and PORP, 3-D CT was also important method. It could present an anatomical relation between those prosthesis and the oval window. High speed helical CT can scan an object more quickly and clearly than formerly used CT, and its biological damage for human is less than that of the others. 3-D CT can be more clearly reconstructed with helical CT than former CT. (author).

  13. Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Hara, Takanori; Urikura, Atsushi; Ichikawa, Katsuhiro; Hoshino, Takashi; Nishimaru, Eiji; Niwa, Shinji

    2016-04-01

    To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor (P) and gantry rotation time (R). The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of pitch factor of >1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 (R/P=0.285/1.5) and 0.074s (R/P=0.285/3.2), and the maximum TR values of the 64×0.5- and 160×0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 (R/P=0.275/1.375) and 0.195s (R/P=0.3/0.6), respectively. Because the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Hypervascular hepatocellular carcinomas: detection with gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Hiromitsu; Kim, Tonsok; Hori, Masatoshi; Nakaya, Yasuhiro; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tatsumi, Mitsuaki; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan); Imai, Yasuharu [Ikeda Municipal Hospital, Department of Gastroenterology, Ikeda, Osaka (Japan); Nagano, Hiroaki [Osaka University Graduate School of Medicine, Department of Surgery, Suita, Osaka (Japan); Kumano, Seishi; Okada, Masahiro; Murakami, Takamichi [Kinki University School of Medicine, Department of Radiology, Osakasayama, Osaka (Japan); Takamura, Manabu [Ikeda Municipal Hospital, Department of Radiology, Ikeda, Osaka (Japan); Wakasa, Kenichi [Osaka City University Graduate School of Medicine, Department of Diagnostic Pathology, Osaka, Osaka (Japan)

    2012-04-15

    To retrospectively compare the accuracy of detection of hypervascular hepatocellular carcinoma (HCC) by multiphasic multidetector CT and by gadoxetate disodium-enhanced MR imaging. After ethical approval, we analysed a total of 73 hypervascular HCC lesions from 31 patients suspected of having HCC, who underwent both gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Five blinded observers independently reviewed CT images, as well as dynamic MR images alone and combined with hepatobiliary phase MR images. Diagnostic accuracy (Az values), sensitivities and positive predictive values were compared by using the Scheffe post hoc test. The mean Az value for dynamic and hepatobiliary phase MR combined (0.81) or dynamic MR images alone (0.78) was significantly higher than that for CT images (0.67, P < 0.001, 0.005, respectively). The mean sensitivity of the combined MR images (0.67) was significantly higher than that of dynamic MR alone (0.52, P < 0.05) or CT images (0.44, P < 0.05). The mean positive predictive values were 0.96, 0.95 and 0.94, for CT, dynamic MR alone and combined MR images, respectively. Compared with multiphasic multidetector CT, gadoxetate disodium-enhanced MR imaging combining dynamic and hepatobiliary phase images results in significantly improved sensitivity and diagnostic accuracy for detection of hypervascular HCC. (orig.)

  15. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs

    International Nuclear Information System (INIS)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe; Suppressa, Patrizia; Cirulli, Anna; Sabba', Carlo

    2005-01-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT [it

  16. Dosimetric comparison of stereotactic body radiotherapy using 4D CT and multiphase CT images for treatment planning of lung cancer: Evaluation of the impact on daily dose coverage

    International Nuclear Information System (INIS)

    Wang Lu; Hayes, Shelly; Paskalev, Kamen; Jin Lihui; Buyyounouski, Mark K.; Ma, Charlie C.-M.; Feigenberg, Steve

    2009-01-01

    Purpose: To investigate the dosimetric impact of using 4D CT and multiphase (helical) CT images for treatment planning target definition and the daily target coverage in hypofractionated stereotactic body radiotherapy (SBRT) of lung cancer. Materials and methods: For 10 consecutive patients treated with SBRT, a set of 4D CT images and three sets of multiphase helical CT scans, taken during free-breathing, end-inspiration and end-expiration breath-hold, were obtained. Three separate planning target volumes (PTVs) were created from these image sets. A PTV 4D was created from the maximum intensity projection (MIP) reconstructed 4D images by adding a 3 mm margin to the internal target volume (ITV). A PTV 3CT was created by generating ITV from gross target volumes (GTVs) contoured from the three multiphase images. Finally, a third conventional PTV (denoted PTV conv ) was created by adding 5 mm in the axial direction and 10 mm in the longitudinal direction to the GTV (in this work, GTV = CTV = clinical target volume) generated from free-breathing helical CT scans. Treatment planning was performed based on PTV 4D (denoted as Plan-1), and the plan was adopted for PTV 3CT and PTV conv to form Plan-2 and Plan-3, respectively, by superimposing 'Plan-1' onto the helical free-breathing CT data set using modified beam apertures that conformed to either PTV 3CT or PTV conv . We first studied the impact of PTV design on treatment planning by evaluating the dosimetry of the three PTVs under the three plans, respectively. Then we examined the effect of the PTV designs on the daily target coverage by utilizing pre-treatment localization CT (CT-on-rails) images for daily GTV contouring and dose recalculation. The changes in the dose parameters of D 95 and D 99 (the dose received by 95% and 99% of the target volume, respectively), and the V p (the volume receiving the prescription dose) of the daily GTVs were compared under the three plans before and after setup error correction

  17. Acute pulmonary embolism in helical computed tomography

    International Nuclear Information System (INIS)

    Paslawski, M.

    2005-01-01

    Pulmonary embolism is a common condition in which diagnostic and therapeutic delays contribute to substantial morbidity and mortality. Clinical diagnosis is difficult because the signs and symptoms re unspecific, and a differential diagnosis is extensive, including pneumonia or bronchitis, asthma, myocardial infraction, pulmonary edema, anxiety, dissection of the aorta, pericardial tamponade, lung cancer, primary pulmonary hypertension, rib fracture, and pneumothorax. The purpose of the study was to present the use of CT in diagnosing acute pulmonary embolism. A group of 23 patients with clinically suspected pulmonary embolism underwent CT examination with a helical CT scanner (Somatom Emotion, Siemens) before and after administration of 150 ml of Ultravist. Pulmonary embolism was found in the CT examinations of 13 patients. In two of these it was a central filling defect. Amputation of the artery was found in one. Parietal filling defect in three patients formed an acute angle with the vessel walls. Saddle emboli appearing as filling defects in the contrast column that hung over vessel bifurcations was found in two patients. In five patients,emboli were found in small segmental arteries. CT provides information not only on the pulmonary arteries, but also on the lung parenchyma, hila, mediastinum, and the heart. Alternative findings may be identified by CT chest examination, stablishing alternative diagnoses, including pulmonary disorders (such as pneumonia or fibrosis), pleural abnormalities, and cardiovascular disease (such as aortic dissection or pericardial tamponade). Another advantage of the CT is its widespread availability.(author)

  18. Posterior Urethra Rupture: Contrast-Enhanced Computed Tomography Scan and Urethrocystography Demonstrations

    Directory of Open Access Journals (Sweden)

    Wojciech Marks

    2012-01-01

    Full Text Available In the follow-up study of patients with pelvic fractures, rupture of the posterior urethra is registered in 3–25% of cases (Koraitim et al., 1996. The diagnostic gold standard for the assessment of hemodynamically stable trauma patients is contrast-enhanced CT scan, especially helical CT. Nevertheless, simultaneous suprapubic cystography and ascending urethrograms (the so-called up-and-downogram are the investigation of choice in assessing the site, severity, and length of urethral injuries. (Carlin and Resnick, 1995 This paper discusses the evaluation and diagnosis of urethral injury in multiple-trauma patient.

  19. Intense Adrenal Enhancement: A CT Feature of Cardiogenic Shock

    International Nuclear Information System (INIS)

    Hrabak-Paar, Maja

    2016-01-01

    In this report, images of intense adrenal enhancement in a 79-year-old female patient with right-sided heart failure and severe tricuspid insufficiency are presented. Only two cases of intense adrenal enhancement as a sign of cardiogenic shock were previously reported in the literature. Intense adrenal enhancement could be one of the earliest CT signs of cardiogenic shock. Its presence should be immediately reported to the referring physician as a sign of significant hemodynamic instability warranting early critical-care management

  20. Intense Adrenal Enhancement: A CT Feature of Cardiogenic Shock

    Energy Technology Data Exchange (ETDEWEB)

    Hrabak-Paar, Maja, E-mail: maja.hrabak.paar@mef.hr [University of Zagreb School of Medicine, Department of Diagnostic and Interventional Radiology, University Hospital Center Zagreb (Croatia)

    2016-02-15

    In this report, images of intense adrenal enhancement in a 79-year-old female patient with right-sided heart failure and severe tricuspid insufficiency are presented. Only two cases of intense adrenal enhancement as a sign of cardiogenic shock were previously reported in the literature. Intense adrenal enhancement could be one of the earliest CT signs of cardiogenic shock. Its presence should be immediately reported to the referring physician as a sign of significant hemodynamic instability warranting early critical-care management.

  1. Scanning technology with multi-slice helical CT in security inspection domain

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Jiang Zenghui

    2008-01-01

    The paper analyzes the technology conditions of security inspection in home and abroad, and expatiates technology of spiral CT and how to define CT value etc, with studying on the key technology of spiral CT scanning way (X-RAY, detector, technology of pulley etc) and mutual relation. By comparing the present products of security inspection, the conclusion was drawn that it is inevitable to develop the tendency of security inspection area with the checking and discerning the substance by using the technology of multi-layer spiral CT. (authors)

  2. Improved particle confinement in transition from multiple-helicity to quasi-single-helicity regimes of a reversed-field pinch.

    Science.gov (United States)

    Frassinetti, L; Predebon, I; Koguchi, H; Yagi, Y; Hirano, Y; Sakakita, H; Spizzo, G; White, R B

    2006-10-27

    The quasi-single-helicity (QSH) state of a reversed-field pinch (RFP) plasma is a regime in which the RFP configuration can be sustained by a dynamo produced mainly by a single tearing mode and in which a helical structure with well-defined magnetic flux surfaces arises. In this Letter, we show that spontaneous transitions to the QSH regime enhance the particle confinement. This improvement is originated by the simultaneous and cooperative action of the increase of the magnetic island and the reduction of the magnetic stochasticity.

  3. Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography

    International Nuclear Information System (INIS)

    Luboldt, W.; Kroll, M.; Wetter, A.; Vogl, T.J.; Toussaint, T.L.; Hoepffner, N.; Holzer, K.; Kluge, A.

    2004-01-01

    A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps 0 . The slope m was determined by linear regression in the correlation (lesion ∝[xA + (1 - x)V]//H) and the Y-intercept y 0 by the minimal shift of the line needed to maximize the accuracy of separating the colonic wall from the lesions. The CT value of the lesions correlated best with the intermediate phase: 0.4A+ 0.6V(r=0.8 for polyps ≥10 mm, r=0.6 for carcinomas, r=0.4 for polyps <10 mm). The accuracy in the differentiation between lesions and normal colonic wall increased with the height implemented as divisor, reached 91% and was obtained by the dynamic cut-off described by the formula: cut-off(A,V,H) = 1.1[0.4A + 0.6V]/H + 69.8. The CT value of colonic polyps or carcinomas can be increased extrinsically by scanning in the phase in which 0.4A + 0.6V reaches its maximum. Differentiating lesions from normal colon based on CT values is possible in contrast-enhanced CTC and improves when the cut-off is adjusted (normalized) to the contrast phase and lesion size. (orig.)

  4. Focal eosinophilic necrosis of the liver in patients with underlying gastric or colorectal cancer: CT differentiation from metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hyun Jung; Lee, Won Jae; Lee, Soon Jin; Kim, Seung Hoon; Lim, Hyo K.; Lim, Jae Hoon [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2002-12-01

    To determine the helical CT findings which help differentiate between focal eosinophilic necrosis (FEN) of the liver and metastasis in patients with underlying gastric or colorectal cancer. In 21 patients with underlying gastric and colorectal cancer examined during a recent 18-month period, the presence of FEN (n=90) was proven at CT. The diagnosis was verified by biopsy in eight patients and by the transient nature of the findings related to peripheral eosinophilia (>10%) in the remainder. For comparison, 20 consecutive patients with pathologically proven hepatic metastasis from gastric or colorectal cancer (n=158) were selected. Single-phase helical CT images (7-mm collimation, pitch 1:1) were independently analyzed in a random order by two blinded readers. The parameters evaluated included the margin (depicted border, fuzzy), shape (spherical, non-spherical), attenuation (subtle hypoattenuation, hypoattenuation), and the presence or absence of rim enhancement. FEN far more frequently showed a fuzzy margin (81%, 84%), subtle hypoattenuation (89%, 91%), and a non-spherical shape (84% for both readers) than metastasis, for which the respective findings were 6%, 22%; 20%, 39%; and 15%, 23%. Rim enhancement was seldom found in FEN (0%, 2%), but was recognized by both readers in 40% of metastases. For all parameters, the results were statistically significant (p < .01), and showed that both readers correctly differentiated FEN from metastasis in 78% of the patients (32/41). Interobserver agreement was, in addition, excellent ({kappa}= 0.66). When focal hepatic lesions with a fuzzy margin, non-spherical shape and subtle hypoattenuation without rim enhancement are found, the possibility of FEN should be considered even in patients with underlying gastrointestinal malignancy.

  5. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  6. Synergistic Enhancement of Microwave Absorption Using Hybridized Polyaniline@helical CNTs with Dual Chirality.

    Science.gov (United States)

    Tian, Xin; Meng, Fanbin; Meng, Fanchen; Chen, Xiangnan; Guo, Yifan; Wang, Ying; Zhu, Wenjun; Zhou, Zuowan

    2017-05-10

    In this study, we designed a dual-chirality hierarchical structure to achieve a synergistically enhanced effect in microwave absorption via the hybridization of nanomaterials. Herein, polyaniline (PANi) nanorods with tunable chirality are grown on helical carbon nanotubes (HCNTs), a typical nanoscale chiral structure, through in situ polymerization. The experimental results show that the hierarchical hybrids (PANi@HCNTs) exhibit distinctly dual chirality and a significant enhancement in electromagnetic (EM) losses compared to those of either pure PANi or HCNTs. The maximum reflection loss of the as-prepared hybrids can reach -32.5 dB at 8.9 GHz. Further analysis demonstrates that combinations of chiral acid-doped PANi and coiled HCNTs with molecular and nanoscale chirality lead to synergistic effects resulting from the dual chirality. The so-called cross-polarization may result in additional interactions with induced EM waves in addition to multiscaled relaxations from functional groups and interfacial polarizations, which can benefit EM absorption.

  7. Quantitative evaluation in enhancement of pancreas and adjacent vessels during spiral CT

    International Nuclear Information System (INIS)

    Kim, Hyoung Seuk; Shin, Kue Hee; Park, Cheol Min; Cha, Sang Hoon; Chung, Kyoo Byung

    1997-01-01

    To determine by quantitative evaluation of pancreatic and adjacent vascular enhancement during spiral CT, the ideal scan delay for examination of the pancreas. Dual(n=3D90) and triple(n=3D90) phase spiral CT scans of patients whose pancreas showed no pathologic condition were retrospectively evaluated. Dual-phase scans were performed at 43 seconds(early), and 5-6 minutes(delayed) after the injection of 120ml of contrast material at an injection rate of 3ml/sec;triple-phase scans were performed at 25 seconds(arterial),60-65 seconds (portal) and 5-6 minutes (delayed) after the injection of 120-140ml of contrast material at an injection rate of 2-4ml/sec, and ten patients also underwent precontrast scanning. CT attenuation values(HU) were measured in the head, body and tail of the pancreas, aorta, and main portal vein during each phase of all scans. Triple-phase protocol was used to measure the effect of different total volumes and injection rates on enhancement of the pancreas and adjacent vessels. There was no significant difference in the degree of enhancement of the pancreas head, body and tail during each phase(p>0.05). The pancreas was maximally enhanced on 43 second delayed scan(132±20HU)(p 0.05). The main portal vein showed maximum enhancement on 43-second delayed scan(207±44HU)(p<0.05). Different total volume of contrast material did not change the enhancement of the pancreas and adjacent vessels. At an injection rate of 2ml/sec, peak enhancement of the pancreas, aorta and portal vein was obtained on 60-65 second delayed scan, and at 4ml/sec, peak enhancement was obtained on 25 second delayed scan(p<0.05). Observing the usual protocols for abdominal spiral CT scanning, the pancreas was most effectively evaluated using a 43-second delayed scan. An increased injection rate resulted in earlier enhancement of the pancreas, aorta and portal vein

  8. Hepatic hemangioma: contrast enhancement patterns on two-phase spiral CT

    International Nuclear Information System (INIS)

    Yun, Eun Joo; Choi, Byung Ihn; Han, Joon Koo; Jang, Hyun Jung; Kim, Tae Kyoung; Kim, Ah Young; Lee, Ki Yeol

    1998-01-01

    To evaluate contrast enhancement patterns of hemangioma according to size, as seen during the arterial and portal venous phase of spiral CT. Overall, the most common enhancement pattern was peripheral high (44/82, 53.7%), during the arterial and portal venous phase. The second and third most common patterns were uniform high (11/82, 13.4%) and peripheral high-uniform high (9/82, 11.0%), also during the arterial and portal venous phase. In tumors smaller than 20 mm, low-low attenuation was seen in eight (9.8%), and iso-low attenuation in two (2.4%), during the arterial and portal venous phase, respectively. On two-phase spiral CT, the most common enhancement pattern of hemangioma was peripheral high, seen during the arterial and portal venous phase. However, a small hemangioma less than 2cm may show atypical patterns, including low and iso attenuation. (author). 23 refs., 1 tab., 4 figs

  9. Prospective evaluation of MRI, {sup 11}C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, H.A., E-mail: vargasah@mskcc.org [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Akin, O.; Schöder, H. [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Olgac, S. [Department of Pathology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Dalbagni, G. [Department of Surgery, Urology Service, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Hricak, H. [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Bochner, B.H. [Department of Surgery, Urology Service, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-12-15

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), {sup 11}C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, {sup 11}C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, {sup 11}C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, {sup 11}C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  10. Non-tumor enhancement at the surgical margin on CT after the removal of brain tumors

    International Nuclear Information System (INIS)

    Adachi, Michito; Hosoya, Takaaki; Yamaguchi, Kohichi; Yamada, Kiyotada

    1992-01-01

    Marginal enhancement is occasionally seen at the surgical margin on CT after the total removal of brain tumors. This enhancement disappears in due time, and therefore we call it non-tumor enhancement. It is often difficult, however, to differentiate non-tumor enhancement from tumor recurrence. In this study, we attempted to determine the characteristics of non-tumor enhancement. The subjects of the study consisted of 15 patients with astrocytoma and one with metastatic tumor in whom sequential CT scans had been performed after total removal of the tumor. Based on the observation of these sequential CT scans, the characteristics of non-tumor enhancement were presumed to be as follows: (1) In four cases, enhancement at the surgical margin persisted more than four months after surgery and then disappeared. Therefore, these cases were considered non-tumor enhancement. Prolonged duration of enhancement such as that in these cases is not necessarily due to recurrence. Marginal enhancement within 3 mm in thickness and with a well-demarcated border like that of a flax is likely to be non-tumor enhancement. (author)

  11. Godbillon Vey Helicity and Magnetic Helicity in Magnetohydrodynamics

    Science.gov (United States)

    Webb, G. M.; Hu, Q.; Anco, S.; Zank, G. P.

    2017-12-01

    The Godbillon-Vey invariant arises in homology theory, and algebraic topology, where conditions for a layered family of 2D surfaces forms a 3D manifold were elucidated. The magnetic Godbillon-Vey helicity invariant in magnetohydrodynamics (MHD) is a helicity invariant that occurs for flows, in which the magnetic helicity density hm= A\\cdotB=0 where A is the magnetic vector potential and B is the magnetic induction. Our purpose is to elucidate the evolution of the magnetic Godbillon-Vey field η =A×B/|A|2 and the Godbillon-Vey helicity hgv}= η \\cdot∇ × η in general MHD flows in which the magnetic helicity hm≠q 0. It is shown that hm acts as a source term in the Godbillon-Vey helicity transport equation, in which hm is coupled to hgv via the shear tensor of the background flow. The transport equation for hgv depends on the electric field potential ψ , which is related to the gauge for A, which takes its simplest form for the advected A gauge in which ψ =A\\cdot u where u is the fluid velocity.

  12. Solitary pulmonary nodules: Comparison of dynamic first-pass contrast-enhanced perfusion area-detector CT, dynamic first-pass contrast-enhanced MR imaging, and FDG PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Seki, Shinichiro; Tsubakimoto, Maho; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2015-02-01

    To prospectively compare the capabilities of dynamic perfusion area-detector computed tomography (CT), dynamic magnetic resonance (MR) imaging, and positron emission tomography (PET) combined with CT (PET/CT) with use of fluorine 18 fluorodeoxyglucose (FDG) for the diagnosis of solitary pulmonary nodules. The institutional review board approved this study, and written informed consent was obtained from each subject. A total of 198 consecutive patients with 218 nodules prospectively underwent dynamic perfusion area-detector CT, dynamic MR imaging, FDG PET/CT, and microbacterial and/or pathologic examinations. Nodules were classified into three groups: malignant nodules (n = 133) and benign nodules with low (n = 53) or high (n = 32) biologic activity. Total perfusion was determined with dual-input maximum slope models at area-detector CT, maximum and slope of enhancement ratio at MR imaging, and maximum standardized uptake value (SUVmax) at PET/CT. Next, all indexes for malignant and benign nodules were compared with the Tukey honest significant difference test. Then, receiver operating characteristic analysis was performed for each index. Finally, sensitivity, specificity, and accuracy were compared with the McNemar test. All indexes showed significant differences between malignant nodules and benign nodules with low biologic activity (P Dynamic perfusion area-detector CT is more specific and accurate than dynamic MR imaging and FDG PET/CT in the diagnosis of solitary pulmonary nodules in routine clinical practice. © RSNA, 2014.

  13. Applications of contrast enhanced CT through external jugular access

    International Nuclear Information System (INIS)

    Xu Qiaolan; Zou Wenxing; Chen Meixia; Xie Hongbo

    2005-01-01

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  14. Applications of contrast enhanced CT through external jugular access

    Energy Technology Data Exchange (ETDEWEB)

    Qiaolan, Xu; Wenxing, Zou; Meixia, Chen; Hongbo, Xie [The First Affiliated Hospital of Sun Yat-sen University, Guangzhou (China). Dept. of Radiology

    2005-09-15

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  15. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J. [University Hospital of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-07-15

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  16. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    International Nuclear Information System (INIS)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J.

    2008-01-01

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  17. Helical tomotherapy as a new treatment technique for whole abdominal irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rochet, N.; Sterzing, F.; Jensen, A.; Herfarth, K.; Schubert, K.; Debus, J.; Harms, W. [Heidelberg Univ. (Germany). Dept. of Radiation Oncology; Dinkel, J. [German Cancer Research Center (dkfz), Heidelberg (Germany). Dept. of Radiology; Eichbaum, M.; Schneeweiss, A.; Sohn, C. [Heidelberg Univ. (Germany). Dept. of Gynecology and Obstetrics

    2008-03-15

    Purpose: To describe a new intensity-modulated radiotherapy (IMRT) technique using helical tomotherapy for whole abdominal irradiation (WAI) in patients with advanced ovarian cancer. Material and Methods: A patient with radically operated ovarian cancer FIGO stage IIIc was treated in a prospective clinical trial with WAI to a total dose of 30 Gy in 1.5-Gy fractions as an additional therapy after adjuvant platinum-based chemotherapy. The planning target volume (PTV) included the entire peritoneal cavity. PTV was adapted according to breathing motion as detected in a four-dimensional respiratory-triggered computed tomography (4D-CT). Inverse treatment planning was done with the Hi-Art tomotherapy planning station. Organs at risk (OARs) were kidneys, liver, bone marrow, spinal cord, thoracic and lumbosacral vertebral bodies, and pelvic bones. Daily control of positioning accuracy was performed with megavoltage computed tomography (MV-CT). Results: Helical tomotherapy enabled a very homogeneous dose distribution with excellent sparing of OARs and coverage of the PTV (V90 of 93.1%, V95 of 86.9%, V105 of 1.9%, and V110 of 0.01%). Mean liver dose was 21.57 Gy and mean kidney doses were 9.75 Gy and 9.14 Gy, respectively. Treatment could be performed in 18.1 min daily and no severe side effects occurred. Conclusion: Helical tomotherapy is feasible and fast for WAI. Tomotherapy enabled excellent coverage of the PTV and effective sparing of liver, kidneys and bone marrow. (orig.)

  18. Helical tomotherapy as a new treatment technique for whole abdominal irradiation

    International Nuclear Information System (INIS)

    Rochet, N.; Sterzing, F.; Jensen, A.; Herfarth, K.; Schubert, K.; Debus, J.; Harms, W.; Dinkel, J.; Eichbaum, M.; Schneeweiss, A.; Sohn, C.

    2008-01-01

    Purpose: To describe a new intensity-modulated radiotherapy (IMRT) technique using helical tomotherapy for whole abdominal irradiation (WAI) in patients with advanced ovarian cancer. Material and Methods: A patient with radically operated ovarian cancer FIGO stage IIIc was treated in a prospective clinical trial with WAI to a total dose of 30 Gy in 1.5-Gy fractions as an additional therapy after adjuvant platinum-based chemotherapy. The planning target volume (PTV) included the entire peritoneal cavity. PTV was adapted according to breathing motion as detected in a four-dimensional respiratory-triggered computed tomography (4D-CT). Inverse treatment planning was done with the Hi-Art tomotherapy planning station. Organs at risk (OARs) were kidneys, liver, bone marrow, spinal cord, thoracic and lumbosacral vertebral bodies, and pelvic bones. Daily control of positioning accuracy was performed with megavoltage computed tomography (MV-CT). Results: Helical tomotherapy enabled a very homogeneous dose distribution with excellent sparing of OARs and coverage of the PTV (V90 of 93.1%, V95 of 86.9%, V105 of 1.9%, and V110 of 0.01%). Mean liver dose was 21.57 Gy and mean kidney doses were 9.75 Gy and 9.14 Gy, respectively. Treatment could be performed in 18.1 min daily and no severe side effects occurred. Conclusion: Helical tomotherapy is feasible and fast for WAI. Tomotherapy enabled excellent coverage of the PTV and effective sparing of liver, kidneys and bone marrow. (orig.)

  19. Radiofrequency ablation of liver cancer: early evaluation of therapeutic response with contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Choi, Dong Gil; Lim, Hyo K.; Lee, Won Jae; Kim, Seung Hoon; Kim, Min Ju; Kim, Seung Kwon; Jang, Kyung Mi; Lee, Ji Yeon; Lim, Jae Hoon

    2004-01-01

    The early assessment of the therapeutic response after percutaneous radiofrequency (RF) ablation is important, in order to correctly decide whether further treatment is necessary. The residual unablated tumor is usually depicted on contrast-enhanced multiphase helical computed tomography (CT) as a focal enhancing structure during the arterial and portal venous phases. Contrast-enhanced color Doppler and power Doppler ultrasonography (US) have also been used to detect residual tumors. Contrast-enhanced gray-scale US, using a harmonic technology which has recently been introduced, allows for the detection of residual tumors after ablation, without any of the blooming or motion artifacts usually seen on contrast-enhanced color or power Doppler US. Based on our experience and reports in the literature, we consider that contrast-enhanced gray-scale harmonic US constitutes a reliable alternative to contrast-enhanced multiphase CT for the early evaluation of the therapeutic response to RF ablation for liver cancer. This technique was also useful in targeting any residual unablated tumors encountered during additional ablation

  20. Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Yoshiya, Kazuhisa; Shimazu, Takeshi [Osaka University Graduate School of Medicine, Department of Traumatology and Acute Critical Medicine, Osaka (Japan)

    2014-04-15

    Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage. (orig.)

  1. Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage.

    Science.gov (United States)

    Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Yoshiya, Kazuhisa; Shimazu, Takeshi; Tomiyama, Noriyuki

    2014-04-01

    Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage.

  2. Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage

    International Nuclear Information System (INIS)

    Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Tomiyama, Noriyuki; Yoshiya, Kazuhisa; Shimazu, Takeshi

    2014-01-01

    Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage. (orig.)

  3. Cranial CT with 64-, 16-, 4- and single-slice CT systems-comparison of image quality and posterior fossa artifacts in routine brain imaging with standard protocols

    Energy Technology Data Exchange (ETDEWEB)

    Ertl-Wagner, Birgit; Eftimov, Lara; Becker, Christoph; Reiser, Maximilian [University of Munich, Grosshadern (Germany). Institute of Clinical Radiology; Blume, Jeffrey; Cormack, Jean [Brown University, Center for Statistical Sciences, Providence, RI (United States); Bruening, Roland; Brueckmann, Hartmut [University of Munich, Grosshadern (Germany). Department of Neuroradiology

    2008-08-15

    Posterior fossa artifacts constitute a characteristic limitation of cranial CT. To identify practical benefits and drawbacks of newer CT systems with reduced collimation in routine cranial imaging, we aimed to investigate image quality, posterior fossa artifacts and parenchymal delineation in non-enhanced CT (NECT) with 1-, 4-, 16- and 64-slice scanners using standard scan protocols. We prospectively enrolled 25 consecutive patients undergoing NECT on a 64-slice CT. Three groups with 25 patients having undergone NECT on 1-, 4- and 16-slice CT machines were matched regarding age and sex. Standard routine CT parameters were used on each CT system with helical acquisition in the posterior fossa; the parameters varied regarding collimation and radiation dose. Three blinded readers independently assessed the cases regarding image quality, infra- and supratentorial artifacts and delineation of brain parenchymal structures on a five-point ordinal scale. Reading orders were randomized. A proportional odds model that accounted for the correlated nature of the data was fit using generalized estimating equations. Posterior fossa artifacts were significantly reduced, and the delineation of infratentorial brain structures was significantly improved with the thinner collimation used for the newer CT systems (p<0.001). No significant differences were observed for midbrain structures (p>0.5). The thinner collimation available on modern CT systems leads to reduced posterior fossa artifacts and to a better delineation of brain parenchyma in the posterior fossa. (orig.)

  4. Reduced bispectrum seeded by helical primordial magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Hortúa, Héctor Javier [Universidad Nacional de Colombia-Bogotá, Facultad de Ciencias, Departamento de Física, Carrera 30 Calle 45-03, C.P. 111321 Bogotá (Colombia); Castañeda, Leonardo, E-mail: hjhortuao@unal.edu.co, E-mail: lcastanedac@unal.edu.co [Grupo de Gravitación y Cosmología, Observatorio Astronómico Nacional, Universidad Nacional de Colombia, cra 45 No 26-85, Edificio Uriel Gutierréz, Bogotá, D.C. (Colombia)

    2017-06-01

    In this paper, we investigate the effects of helical primordial magnetic fields (PMFs) on the cosmic microwave background (CMB) reduced bispectrum. We derive the full three-point statistics of helical magnetic fields and numerically calculate the even contribution in the collinear configuration. We then numerically compute the CMB reduced bispectrum induced by passive and compensated PMF modes on large angular scales. There is a negative signal on the bispectrum due to the helical terms of the fields and we also observe that the biggest contribution to the bispectrum comes from the non-zero IR cut-off for causal fields, unlike the two-point correlation case. For negative spectral indices, the reduced bispectrum is enhanced by the passive modes. This gives a lower value of the upper limit for the mean amplitude of the magnetic field on a given characteristic scale. However, high values of IR cut-off in the bispectrum, and the helical terms of the magnetic field relaxes this bound. This demonstrates the importance of the IR cut-off and helicity in the study of the nature of PMFs from CMB observations.

  5. Invaded depth of extrahepatic bile duct cancer diagnosed on angiographic CT during late contrast enhancement

    International Nuclear Information System (INIS)

    Kikuyama, Masataka; Sasada, Yuzo; Koide, Shigeki; Hirai, Ritsuko; Oota, Yuji

    2006-01-01

    Thirteen patients with extrahepatic bile duct cancer were evaluated for enhancement pattern and tumor feature during late contrast enhancement on angiographic CT (AG-CT), performed before surgery. Eleven patients with late contrast enhancement had advanced cancers with invasion over the subserosal layer. Eight of these patients whose cancer had an irregular outer layer had invasion over the serosal layer (≥panc 1 b, General Rules for Surgical and Pathological Studies on Cancer of the Biliary Tract, Japanese Society of Biliary Surgery). Seven of the 13 patients had intra-pancreatic bile duct cancer. Among them, five had an irregular outer layer of the intra-pancreatic bile duct cancer; one of three with a wall thickness under 5 mm on AG-CT had panc 1 b invasion, and the other two had panc 2 (General Rules for Surgical and Pathological Studies on Cancer of the Biliary Tract, Japanese Society of Biliary Surgery) invasion. Two with a wall thickness over 5 mm on AG-CT had panc 2 invasion. These results suggest that late contrast enhancement on AG-CT is effective for diagnosing the depth of tumor invasion of the bile duct. (author)

  6. Overranging at multisection CT: an underestimated source of excess radiation exposure.

    NARCIS (Netherlands)

    Schilham, A.; Molen, A.J. van der; Prokop, M.; Jong, H.W. de

    2010-01-01

    To reconstruct the first and last sections of a helical computed tomographic (CT) scan, the scan length is automatically extended beyond the planned image boundaries, a phenomenon known as overranging. With common 16-section CT scanning protocols, the overrange length is between 3 and 6 cm. For

  7. Impact of new technologies on dose reduction in CT

    International Nuclear Information System (INIS)

    Lee, Ting-Yim; Chhem, Rethy K.

    2010-01-01

    The introduction of slip ring technology enables helical CT scanning in the late 1980's and has rejuvenated CT's role in diagnostic imaging. Helical CT scanning has made possible whole body scanning in a single breath hold and computed tomography angiography (CTA) which has replaced invasive catheter based angiography in many cases because of its easy of operation and lesser risk to patients. However, a series of recent articles and accidents have heightened the concern of radiation risk from CT scanning. Undoubtedly, the radiation dose from CT studies, in particular, CCTA studies, are among the highest dose studies in diagnostic imaging. Nevertheless, CT has remained the workhorse of diagnostic imaging in emergent and non-emergent situations because of their ubiquitous presence in medical facilities from large academic to small regional hospitals and their round the clock accessibility due to their ease of use for both staff and patients as compared to MR scanners. The legitimate concern of radiation dose has sparked discussions on the risk vs benefit of CT scanning. It is recognized that newer CT applications, like CCTA and perfusion, will be severely curtailed unless radiation dose is reduced. This paper discusses the various hardware and software techniques developed to reduce radiation dose to patients in CT scanning. The current average effective dose of a CT study is ∼10 mSv, with the implementation of dose reduction techniques discussed herein; it is realistic to expect that the average effective dose may be decreased by 2-3 fold.

  8. Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kappes, J.; Hantusch, R.; Hartlieb, S.; Weinheimer, O.; Kauczor, H.-U.; Eberhardt, R.

    2010-01-01

    Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU (9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast application show the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used.

  9. Initial staging of Hodgkin's disease: role of contrast-enhanced 18F FDG PET/CT.

    Science.gov (United States)

    Chiaravalloti, Agostino; Danieli, Roberta; Caracciolo, Cristiana Ragano; Travascio, Laura; Cantonetti, Maria; Gallamini, Andrea; Guazzaroni, Manlio; Orlacchio, Antonio; Simonetti, Giovanni; Schillaci, Orazio

    2014-08-01

    The objective of this study was to compare the diagnostic accuracy of positron emission tomography/low-dose computed tomography (PET/ldCT) versus the same technique implemented by contrast-enhanced computed tomography (ceCT) in staging Hodgkin's disease (HD).Forty patients (18 men and 22 women, mean age 30 ± 9.6) with biopsy-proven HD underwent a PET/ldCT study for initial staging including an unenhanced low-dose computed tomography for attenuation correction with positron emission tomography acquisition and a ceCT, performed at the end of the PET/ldCT scan, in the same exam session. A detailed datasheet was generated for illness locations for separate imaging modality comparison and then merged in order to compare the separate imaging method results (PET/ldCT and ceCT) versus merged results positron emission tomography/contrast-enhanced computed tomography (PET/ceCT). The nodal and extranodal lesions detected by each technique were then compared with follow-up data that served as the reference standard.No significant differences were found at staging between PET/ldCT and PET/ceCT in our series. One hundred and eighty four stations of nodal involvement have been found with no differences in both modalities. Extranodal involvement was identified in 26 sites by PET/ldCT and in 28 by PET/ceCT. We did not find significant differences concerning the stage (Ann Arbor).Our study shows a good concordance and conjunction between PET/ldCT and ceCT in both nodal and extranodal sites in the initial staging of HD, suggesting that PET/ldCT could suffice in most of these patients.

  10. Value of contrast enhanced CT scanning in the non-trauma emergency room patient

    International Nuclear Information System (INIS)

    Wood, L.P.; Parisi, M.; Finch, I.J.

    1990-01-01

    To determine the value of performing contrast CT in addition to non-contrast CT in the evaluation of acute non-traumatic central nervous system disorders, we retrospectively reviewed 322 cases originating from the emergency room at our institution. The most common indication for scanning was seizure activity (34% of total), followed by headache (30%), focal neurological deficit (10%), and altered mental status (8%). 75% of the noncontrast scans were normal. The contrast enhanced scan revealed abnormalities not evident on the non-contrast scan in only three of these cases, and the information did not alter patient management. We conclude that in the acute setting, if a non-contrast CT is normal, a contrast study is usually unnecessary. Therefore, given the additional risks of contrast infusion, the contrast study, if needed, is generally best obtained at a later date, after more careful evaluation of the patient's history and medical records. If the non-contrast CT scan is abnormal, a contrast enhanced CT scan may be beneficial, but, again, is often not needed to direct acute patient management. (orig.)

  11. Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures

    International Nuclear Information System (INIS)

    Catalano, O.; Esposito, M.; Lobianco, R.; Cusati, B.; Altei, F.; Siani, A.

    1999-01-01

    The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in 38%. Morphology was unchanged in 63% of the lesions while in 37% a mild deformation toward the needle path or a more regular and round shape was evident. Borders were unchanged in 37% of the cases and modified in 63%, appearing well-defined in 73% and ill-defined in 27%. The necrotic portion had a low attenuation with a nodule-to-parenchyma gradient more evident on delayed than on venous and finally arterial acquisitions; 8% of the lesions were not recognizable on unenhanced scans. During the arterial phase the residual tumor appeared hyperdense in 97% of the nodules and isodense in 3%, while during the portal phase it was hyperdense in 22%, isodense in 28% and hypodense in 50%, and during the delayed phase hypodense in 100%. Residual viable tissue was identified in 44% of the nodules and quantified as 100% in 1% of all lesions, > 75% in 3%, > 50% in 4%, > 25% in 23%. In conclusion, multiple-phase helical CT allows optimal depiction of primitive liver nodules treated with percutaneous interventional procedures and has a

  12. CT colonography: Diagnostic role of contrast enhancement of benign polyps and colorectal carcinoma

    International Nuclear Information System (INIS)

    Stoinova, V.; Nedevska, M.

    2006-01-01

    Full text: The aim of this study was to compare pre- and postcontrast CT attenuation values of benign colorectal polyps and carcinoma lesions detected by CT colonography, and to investigate whether contrast enhancement of these lesions can be potentially used for differentiation from residual fluid and feces. We retrospectively reviewed CT colonographic dataset of 120 patients. 35 benign polyps and 22 colorectal carcinomas were included in our study. All lesions were confirmed by colonoscopic biopsy or surgery. The difference in attenuation value between precontrast and postcontrast studies of polyps was statistically significant; the same was true for colorectal cancers. In the precontrast phase no statistically significant difference was observed between stool, polyps and cancers. The mean attenuation value of solid fecal residuals was 37 HU before and after contrast enhancement. Residual fluid do not take up contrast and the density does not change in the contrast-enhanced phase. The difference between postcontrast density of polyps and cancers with respect to density of stools and residual fluid was significant. The use of contrast medium could be helpful in CT colonography for discriminating polypoid benign lesions and colorectal cancer from fecal and fluid residuals

  13. Optimized control of X-ray exposure and image noise using a particular multislice CT scanner

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki; Koyama, Yoshihiro; Nagasawa, Hirofumi

    2008-01-01

    Patient dose reduction in computed tomography (CT) always results in a trade off between radiation exposure and image quality. There are few reports that estimate the relationship between image quality and X-ray exposure in CT examinations as one optimal index. The purpose of this study was to determine the optimal parameter settings enabling a low radiation exposure without compromising image quality using a particular 4-row multislice CT (MSCT) scanner (Aquilion VZ 4-slice CT scanner, Toshiba Medical Systems Corporation, Otawara, Tochigi, Japan). Normalized dose divided by image noise for helical pitches (nDNR: normalized dose to noise ratio) were calculated in consideration of beam collimation and tube current-time product. Optimal tube current-time product was calculated using the nDNR for the helical pitches based on user-defined standards of quality of the CT image. As a result, the nDNR proved to be well-supported to decrease the patient exposure in various exposure conditions of MSCT scans; however, the dose and image noise did not show a linear relation to the helical pitch. In conclusion, nDNR can be applied to patient dose reduction while keeping an acceptable image quality using a particular 4-row MSCT scanner. (author)

  14. Normal width of the anterior commissure of true vocal cord in Korea adults measured by helical CT

    International Nuclear Information System (INIS)

    Lim, Woo Young; Lim, Dong Hoon; Moon, Jang Il; Ko, Yong Seok; Byeon, Joo Nam; Oh, Jae Hee

    1998-01-01

    To evaluate the mean width of anterior commissure of true vocal cord in Korean adults by measuring its dimension on spiral CT scans. We reviewed the CT scans of 53 Korean adults(age range, 23-73years; mean age 39.2 years;M:F=3D41:12) without laryngeal disorders. Soiral CT scanning was performed around the anterior commissure with 1mm slice thickness and table incrementation for 15 seconds. The anteroposterior width of the anterior commissure was measured on CT scan where the true vocal cord and arytenoid, cricoid and thyroid cartilages were all present. We determined the mean width of the anterior commissure and whether there was a relationship between age and the width of the anterior commissure. The width of the anterior commissure was between 0.9mm and 2.3mm;mean width was 1.60±0.38mm(mean±SD). Using two SDs above the mean would have defined 2.36mm as the upper limit of normal width. Statistically, no significant correlation existed between the age and the width of the anterior commissure(p>0.05). An awareuess of the normal width range of the anterior commissure in Korean adults evaluated by spiral CT enhances the possibility of early detection of invasion of the anterior commissure by glottic cancer.=20

  15. Cost reduction in abdominal CT by weight-adjusted dose.

    Science.gov (United States)

    Arana, Estanislao; Martí-Bonmatí, Luis; Tobarra, Eva; Sierra, Consuelo

    2009-06-01

    To analyze the influence of contrast dose adjusted by weight vs. fixed contrast dose in the attenuation and cost of abdominal computed tomography (CT). A randomised, consecutive, parallel group study was conducted in 151 patients (74 men and 77 women, age range 22-67 years), studied with the same CT helical protocol. A dose at 1.75 ml/kg was administered in 101 patients while 50 patients had a fixed dose of 120 ml of same non-ionic contrast material (320 mg/ml). Mean enhancements were measured at right hepatic lobe, superior abdominal aorta and inferior cava vein. Statistical analysis was weight-stratified (81 kg). Aortic attenuation was significantly superior (p61 kg in dose-adjusted group, presented higher hepatic attenuation, being statistically significant in those >81 kg (p80 kg, there was an over cost of euro 10.7 per patient. An injection volume of 1.75 ml/kg offers an optimal diagnostic quality with a global savings of euro 1.34 per patient.

  16. Examination of hepatic contrast-enhanced CT monitored by Smart Prep

    International Nuclear Information System (INIS)

    Kakizaki, Dai; Saito, Kazuhiro; Sakurada, Toru; Abe, Kimihiko; Suzuki, Kenji

    1999-01-01

    The aim of the present study is to obtain the time density curves of the contrast-enhanced CT of hepatic portal vein, hepatic and splenic parenchyma, and to examine the relation with age, body weight, type of liver dysfunction. Subjects were 32 patients with liver tumors or liver diseases. For this purpose, the procedure of hepatic CT was monitored by Smart Prep and the images of whole liver was taken when the level of the contrast at the hepatic portal vein reached to the enhancement threshold. The contrast medium used was Iomeprol 300. The adverse reactions by Iomeprol 300 were mild and any treatment did not need. There was no correlation age and weight with enhancement threshold at the hepatic portal vein and peak time at the splenic parenchyma. The enhancement threshold at the hepatic portal vein was various in patients with chrrhosis and chronic hepatitis, and tended to be delayed in patients with chrrhosis. The peak time of the splenic parenchyma was up to 52 seconds in all patients with chronic hepatitis. The shortage of the enhancement threshold and the increase in blood flow at arterial early phase were observed in the patients with advanced acute hepatitis. This method should be examined more cases with various hepatic diseases. (K.H.)

  17. Exposure dose to gonad and its reduction in CT examinations

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Menju, Mina; Nakazawa, Masato

    2006-01-01

    Exposure doses to gonad (ovary and uterus) due to scattering at the ordinary CT examinations of head, breast, and abdomen (liver) were measured and their reductions by the protective apron usually used in clinic were evaluated by comparison of the given and International Commission of Radiological Protection (ICRP) data for risk assessment. Multi-slice helical/scanno-helical CT for the regions under ordinary diagnostic conditions was done by the apparatus Toshiba Aquilion 16 for the human body phantom (Alderson) with or without the apron (Hagoromo) equivalent to 0.25 mm thick lead. Doses inside and outside the beam flux were measured by the thermoluminescent dosimeter, of which data were corrected by Radcal Model 300 ionization chamber. The doses in the gonad due to scattering were found to be in the range from 0.01 (head CT) to 1 (liver CT) mGy and to be reduced in 20-30% by the apron. Found dose were far smaller than the ICRP threshold values for inducing teratosis and infertality. (T.I.)

  18. Multislice helical CT (MSCT) for mid-facial trauma: optimization of parameters for scanning and reconstruction

    International Nuclear Information System (INIS)

    Dammert, S.; Funke, M.; Obernauer, S.; Grabbe, E.; Merten, H.A.

    2002-01-01

    Purpose: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. Material and Methods: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. Results: The best image quality was obtained with a collimation of 4 x 1.25 mm and a - table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). Conclusions: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary. (orig.) [de

  19. Experimental investigation of transverse mixing in porous media under helical flow conditions

    DEFF Research Database (Denmark)

    Ye, Yu; Chiogna, Gabriele; Cirpka, Olaf A.

    2016-01-01

    Plume dilution and transverse mixing can be considerably enhanced by helical flow occurring in three-dimensional heterogeneous anisotropic porous media. In this study, we perform tracer experiments in a fully three-dimensional flow-through chamber to investigate the effects of helical flow on plume...

  20. Spiral CT in kidney: assumption of renal function by objective evaluation of renal cortical enhancement

    International Nuclear Information System (INIS)

    Choi, Bo Yoon; Lee, Jong Seok; Lee, Joon Woo; Myung, Jae Sung; Sim, Jung Suk; Seong, Chang Kyu; Kim, Seung Hyup; Choi, Guk Myeong; Chi, Seong Whi

    2000-01-01

    To correlate the degree of renal cortical enhancement, objectively evaluated by means of spiral CT with the serum level of creatinine, and to determine the extent to which this degree of enhancement may be used to detect renal parenchymal disease. Eighty patients (M:F = 50:30; age + 25-19, (mean 53) years) with available serum level of creatinine who underwent spiral CT between September and October 1999 were included in this study. In fifty patients the findings suggested hepatic or biliary diseases such as hepatoma, biliary cancer, or stone, while in thirty, renal diseases such as cyst, hematoma, or stone appeared to be present. Spiral CT imaging of the cortical phase was obtained at 30-40 seconds after the injection of 120 ml of non-ionic media at a rate of 3 ml/sec. The degree of renal cortical enhancement was calculated by dividing the CT attenuation number of renal cortex at the level of the renal hilum by the CT attenuation number of aorta at the same level. The degree of renal cortical enhancement was compared with the serum level of creatinine, and the degree of renal cortical enhancement in renal parenchymal disease with that of the normal group. Among eighty patients there were five with renal parenchymal disease and 75 with normal renal function. The ratio of the CT attenuation number of renal cortex to that of aorta at the level of the renal hilum ranged between 0.49 and 0.99 (mean, 0.79; standard deviation, 0.15). while the serum level of creatinine ranged between 0.6 and 3.2 mg/dl. There was significant correlation (coefficient of -0.346) and a statistically significant probability of 0.002 between the ratio of the CT attenuation numbers and the serum level of creatinine. There was a significant difference (statistically significant probability of less than 0.01) between those with renal parenchymal disease and the normal group. The use of spiral CT to measure the degree of renal cortical enhancement provides not only an effective index for

  1. Neutronics investigation of advanced self-cooled liquid blanket systems in helical reactor

    International Nuclear Information System (INIS)

    Tanaka, T.; Sagara, A.; Muroga, T.; Youssef, M.Z.

    2006-10-01

    Neutronics performances of advanced self-cooled liquid blanket systems have been investigated in design activity of the helical-type reactor FFHR2. In the present study, a new three-dimensional (3-D) neutronics calculation system has been developed for the helical-type reactor to enhance quick feedback between neutronics evaluation and design modification. Using this new calculation system, advanced Flibe-cooled and Li-cooled liquid blanket systems proposed for FFHR2 have been evaluated to make clear design issues to enhance neutronics performance. Based on calculated results, modification of the blanket dimensions and configuration have been attempted to achieve the adequate tritium breeding ability and neutron shielding performance in the helical reactor. The total tritium breeding ratios (TBRs) obtained after modifying the blanket dimensions indicated that all the advanced blanket systems proposed for FFHR2 would achieve adequate tritium self-sufficiency by dimension adjustment and optimization of structures in the breeder layers. Issues in neutron shielding performance have been investigated quantitatively using 3-D geometry of the helical blanket system, support structures, poloidal coils etc. Shielding performance of the helical coils against direct neutrons from core plasma would achieve design target by further optimization of shielding materials. However, suppression of the neutron streaming and reflection through the divertor pumping areas in the original design is important issue to protect the poloidal coils and helical coils, respectively. Investigation of the neutron wall loading indicated that the peaking factor of the neutron wall load distribution would be moderated by the toroidal and helical effect of the plasma distribution in the helical reactor. (author)

  2. Approximations of noise covariance in multi-slice helical CT scans: impact on lung nodule size estimation.

    Science.gov (United States)

    Zeng, Rongping; Petrick, Nicholas; Gavrielides, Marios A; Myers, Kyle J

    2011-10-07

    Multi-slice computed tomography (MSCT) scanners have become popular volumetric imaging tools. Deterministic and random properties of the resulting CT scans have been studied in the literature. Due to the large number of voxels in the three-dimensional (3D) volumetric dataset, full characterization of the noise covariance in MSCT scans is difficult to tackle. However, as usage of such datasets for quantitative disease diagnosis grows, so does the importance of understanding the noise properties because of their effect on the accuracy of the clinical outcome. The goal of this work is to study noise covariance in the helical MSCT volumetric dataset. We explore possible approximations to the noise covariance matrix with reduced degrees of freedom, including voxel-based variance, one-dimensional (1D) correlation, two-dimensional (2D) in-plane correlation and the noise power spectrum (NPS). We further examine the effect of various noise covariance models on the accuracy of a prewhitening matched filter nodule size estimation strategy. Our simulation results suggest that the 1D longitudinal, 2D in-plane and NPS prewhitening approaches can improve the performance of nodule size estimation algorithms. When taking into account computational costs in determining noise characterizations, the NPS model may be the most efficient approximation to the MSCT noise covariance matrix.

  3. PET/CT and contrast enhanced CT in single vs. two separate sessions: a cost analysis study.

    Science.gov (United States)

    Picchio, M; Mansueto, M; Crivellaro, C; Guerra, L; Marcelli, S; Arosio, M; Sironi, S; Gianolli, L; Grimaldi, A; Messa, C

    2012-06-01

    Aim of the study was to quantify the economic impact of PET/CT and contrast enhanced (c.e.) CT performed in a single session examination vs. stand-alone modalities in oncological patients. One-hundred-forty-five cancer patients referred to both PET/CT and c.e. CT, to either stage (N.=46) or re-stage (N.=99) the disease, were included. Seventy-two/145 performed both studies in a single session (innovative method) and 73/145 in two different sessions (traditional method). The cost-minimization analysis was performed by evaluating: 1) institutional costs, data obtained by hospital accountability (staff, medical materials, equipment maintenance and depreciation, departments utilities); 2) patients costs, data obtained by a specific survey provided to patients (travel, food, accommodation costs, productivity loss). Economic data analysis showed that the costs for innovative method was lower than those of traditional method, both for Institution (106 € less per test) and for patient (21 € less per patient). The loss of productivity for patient and caregivers resulted lower for the innovative method than the traditional method (3 work-hour less per person). PET/CT and c.e. CT performed in a single session is more cost-effective than stand-alone modalities, by reducing both Institutional and patients costs. These advantages are mainly due to lower Institutional cost (single procedure) and to lower cost related to travel and housing.

  4. Hydrodynamic studies of CNT nanofluids in helical coil heat exchanger

    Science.gov (United States)

    Babita; Sharma, S. K.; Mital Gupta, Shipra; Kumar, Arinjay

    2017-12-01

    Helical coils are extensively used in several industrial processes such as refrigeration systems, chemical reactors, recovery processes etc to accommodate a large heat transfer area within a smaller space. Nanofluids are getting great attention due to their enhanced heat transfer capability. In heat transfer equipments, pressure drop is one of the major factors of consideration for pumping power calculations. So, the present work is aimed to study hydrodynamics of CNT nanofluids in helical coils. In this study, pressure drop characteristics of CNT nanofluid flowing inside horizontal helical coils are investigated experimentally. The helical coil to tube diameter was varied from 11.71 to 27.34 keeping pitch of the helical coil constant. Double distilled water was used as basefluid. SDBS and GA surfactants were added to stablilize CNT nanofluids. The volumetric fraction of CNT nanofluid was varied from 0.003 vol% to 0.051 vol%. From the experimental data, it was analyzed that the friction factor in helical coils is greater than that of straight tubes. Concentration of CNT in nanofluids also has a significant influence on the pressure drop/friction factor of helical coils. At a constant concentration of CNT, decreasing helical coil to tube diameter from 27.24 to 11.71, fanning friction factor of helical coil; f c increases for a constant value of p/d t. This increase in the value of fanning friction factor can be attributed to the secondary flow of CNT nanofluid in helical coils.

  5. A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT

    International Nuclear Information System (INIS)

    Cho, Seungryong; Xia, Dan; Pellizzari, Charles A.; Pan Xiaochuan

    2010-01-01

    Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image of the patient is needed for image-guidance procedures. The authors previously developed an algorithm for image reconstruction from nontruncated data of an object that is completely within the reverse helix. The purpose of this work is to develop an image reconstruction approach for reverse helical CBCT of a long object that extends out of the reverse helix and therefore constitutes data truncation. Methods: The proposed approach comprises of two reconstruction steps. In the first step, a chord-based backprojection-filtration (BPF) algorithm reconstructs a volumetric image of an object from the original cone-beam data. Because there exists a chordless region in the middle of the reverse helix, the image obtained in the first step contains an unreconstructed central-gap region. In the second step, the gap region is reconstructed by use of a Pack-Noo-formula-based filteredbackprojection (FBP) algorithm from the modified cone-beam data obtained by subtracting from the original cone-beam data the reprojection of the image reconstructed in the first step. Results: The authors have performed numerical studies to validate the proposed approach in image reconstruction from reverse helical cone-beam data. The results confirm that the proposed approach can reconstruct accurate images of a long object without suffering from data-truncation artifacts or cone-angle artifacts. Conclusions: They developed and validated a BPF-FBP tandem algorithm to reconstruct images of a long object from reverse helical cone-beam data. The chord-based BPF algorithm was utilized for converting the long-object problem into a short-object problem. The proposed approach is applicable to other scanning configurations such as reduced circular sinusoidal trajectories.

  6. Pathologic contrast enhancement of cerebral lesions: A comparative study using stereotactic CT, stereotactic MR imaging, and stereotactic biopsy

    International Nuclear Information System (INIS)

    Earnest, F. IV; Kelly, P.J.; Scheithauer, B.; Kall, B.; Cascino, T.L.; Ehman, R.L.; Forbes, G.

    1986-01-01

    The author compared the pattern and degree of Gd-DTPA dimeglumine contrast enhancement demonstrated on stereotactic MR images with that seen on stereotactic CT images obtained after conventional iodinated contrast agent enhancement and with histopathologic findings on sequential stereotactic brain biopsies. Stereotactic biopsies of the areas that enhanced on CT or MR imaging revealed tumor tissue with neovascularity. Tumor tissue with no or mild neovascularity did not enhance with contrast agent administration. Isolated tumor cells were frequently found beyond the margins of some primary brain neoplasms defined by contrast agent-enhanced MR imaging and CT. The histopathologic findings associated with pathologic contrast agent enhancement are presented

  7. EVOLUTION OF MAGNETIC HELICITY AND ENERGY SPECTRA OF SOLAR ACTIVE REGIONS

    International Nuclear Information System (INIS)

    Zhang, Hongqi; Brandenburg, Axel; Sokoloff, D. D.

    2016-01-01

    We adopt an isotropic representation of the Fourier-transformed two-point correlation tensor of the magnetic field to estimate the magnetic energy and helicity spectra as well as current helicity spectra of two individual active regions (NOAA 11158 and NOAA 11515) and the change of the spectral indices during their development as well as during the solar cycle. The departure of the spectral indices of magnetic energy and current helicity from 5/3 are analyzed, and it is found that it is lower than the spectral index of the magnetic energy spectrum. Furthermore, the fractional magnetic helicity tends to increase when the scale of the energy-carrying magnetic structures increases. The magnetic helicity of NOAA 11515 violates the expected hemispheric sign rule, which is interpreted as an effect of enhanced field strengths at scales larger than 30–60 Mm with opposite signs of helicity. This is consistent with the general cycle dependence, which shows that around the solar maximum the magnetic energy and helicity spectra are steeper, emphasizing the large-scale field

  8. EVOLUTION OF MAGNETIC HELICITY AND ENERGY SPECTRA OF SOLAR ACTIVE REGIONS

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hongqi [Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Brandenburg, Axel [Nordita, KTH Royal Institute of Technology and Stockholm University, Roslagstullsbacken 23, SE-10691 Stockholm (Sweden); Sokoloff, D. D., E-mail: hzhang@bao.ac.cn [Department of Physics, Moscow University, 119992 Moscow (Russian Federation)

    2016-03-10

    We adopt an isotropic representation of the Fourier-transformed two-point correlation tensor of the magnetic field to estimate the magnetic energy and helicity spectra as well as current helicity spectra of two individual active regions (NOAA 11158 and NOAA 11515) and the change of the spectral indices during their development as well as during the solar cycle. The departure of the spectral indices of magnetic energy and current helicity from 5/3 are analyzed, and it is found that it is lower than the spectral index of the magnetic energy spectrum. Furthermore, the fractional magnetic helicity tends to increase when the scale of the energy-carrying magnetic structures increases. The magnetic helicity of NOAA 11515 violates the expected hemispheric sign rule, which is interpreted as an effect of enhanced field strengths at scales larger than 30–60 Mm with opposite signs of helicity. This is consistent with the general cycle dependence, which shows that around the solar maximum the magnetic energy and helicity spectra are steeper, emphasizing the large-scale field.

  9. Ligation of the internal maxillary artery for intractable epistaxis. 3D imaging of internal maxillary artery using helical CT scan

    International Nuclear Information System (INIS)

    Handa, Toru; Yazin, Koji; Hirakawa, Katsuhiro; Fukushima, Noriyuki; Takumida, Masaya; Hirata, Shitau; Iguchi, Tetsuhiko; Amano, Yoshiharu

    2001-01-01

    Sever posterior epistaxis is one of the serious clinical problems. Nasal bleeding usually occurs in the anterior septal region, where it can be seen easily and controlled with topical cautery or localized packing. When the bleeding occurs in the posterior nose, it becomes a more serious problem. Many methods have been used to control posterior epistaxis. Some of these are electrocautery, posterior nasal packing, vascular ligation and therapeutic percutaneous embolization. Between 1997 and 2000, nineteen patients were admitted to our hospital because of intractable epistaxis. There were 16 male and 3 female patients whose average age was 55 years. Ten of 19 patients were hypertensive, and none of these had undergoing treatment. Five of 19 patients received maxillary artery ligation. Clinical applications of 3D imaging of the internal maxillary artery using helical CT scan were done for 5 patients. These images were helpful for planning of ligation of the internal maxillary artery. (author)

  10. Ligation of the internal maxillary artery for intractable epistaxis. 3D imaging of internal maxillary artery using helical CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Handa, Toru [Akitsu Prefectual Hospital, Hiroshima (Japan); Yazin, Koji; Hirakawa, Katsuhiro; Fukushima, Noriyuki; Takumida, Masaya; Hirata, Shitau; Iguchi, Tetsuhiko; Amano, Yoshiharu

    2001-03-01

    Sever posterior epistaxis is one of the serious clinical problems. Nasal bleeding usually occurs in the anterior septal region, where it can be seen easily and controlled with topical cautery or localized packing. When the bleeding occurs in the posterior nose, it becomes a more serious problem. Many methods have been used to control posterior epistaxis. Some of these are electrocautery, posterior nasal packing, vascular ligation and therapeutic percutaneous embolization. Between 1997 and 2000, nineteen patients were admitted to our hospital because of intractable epistaxis. There were 16 male and 3 female patients whose average age was 55 years. Ten of 19 patients were hypertensive, and none of these had undergoing treatment. Five of 19 patients received maxillary artery ligation. Clinical applications of 3D imaging of the internal maxillary artery using helical CT scan were done for 5 patients. These images were helpful for planning of ligation of the internal maxillary artery. (author)

  11. CT urograms in pediatric patients with ureteral calculi: do adult criteria work?

    International Nuclear Information System (INIS)

    Smergel, E.; Greenberg, S.B.; Crisci, K.L.; Salwen, J.K.

    2001-01-01

    Background: Secondary signs of urinary obstruction associated with ureteral calculi are useful adjuncts to diagnosis in adults with renal colic evaluated by unenhanced helical CT. Objective: Our purpose was to evaluate the frequency of secondary signs of obstruction in children with renal colic undergoing unenhanced helical CT. Materials and methods: Ureteral calculi were identified in 20 of 61 children with acute flank pain examined by unenhanced helical CT. Each imaging study was evaluated for the presence of secondary signs of urinary obstruction. The frequencies of individual signs were compared with each other by means of the McNemar test. Results: Six children had no secondary sign identified. In the remaining 14 children, proximal ureteral dilatation was seen in 10, renal enlargement in 10, hydronephrosis in 9, tissue rim sign in 6, decreased kidney attenuation in 5, and perinephric stranding in 1. Comparison of the frequencies strongly suggested that perinephric stranding occurs less frequently than proximal ureteral dilatation (P = 0.004), hydronephrosis (P = 0.008), or renal enlargement (P = 0.012). Conclusion: Perinephric stranding, a common secondary sign in adults with ureteral calculi, occurs less frequently in children than other reported secondary signs. (orig.)

  12. CT urograms in pediatric patients with ureteral calculi: do adult criteria work?

    Energy Technology Data Exchange (ETDEWEB)

    Smergel, E.; Greenberg, S.B.; Crisci, K.L.; Salwen, J.K. [Dept. of Radiology, St. Christopher' s Hospital for Children, Philadelphia, PA (United States)

    2001-10-01

    Background: Secondary signs of urinary obstruction associated with ureteral calculi are useful adjuncts to diagnosis in adults with renal colic evaluated by unenhanced helical CT. Objective: Our purpose was to evaluate the frequency of secondary signs of obstruction in children with renal colic undergoing unenhanced helical CT. Materials and methods: Ureteral calculi were identified in 20 of 61 children with acute flank pain examined by unenhanced helical CT. Each imaging study was evaluated for the presence of secondary signs of urinary obstruction. The frequencies of individual signs were compared with each other by means of the McNemar test. Results: Six children had no secondary sign identified. In the remaining 14 children, proximal ureteral dilatation was seen in 10, renal enlargement in 10, hydronephrosis in 9, tissue rim sign in 6, decreased kidney attenuation in 5, and perinephric stranding in 1. Comparison of the frequencies strongly suggested that perinephric stranding occurs less frequently than proximal ureteral dilatation (P = 0.004), hydronephrosis (P = 0.008), or renal enlargement (P = 0.012). Conclusion: Perinephric stranding, a common secondary sign in adults with ureteral calculi, occurs less frequently in children than other reported secondary signs. (orig.)

  13. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  14. Detection of parenchymal abnormalities in experimentally induced acute pyelonephritis in rabbits using contrast-enhanced ultrasonography, CT, and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Ah; Kim, Bo Hyun; Kim, Seung Kwon; Seo, Jin Won [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Jong Sung [Laboratory Animal Research Center, Samsung Biomedical Research Institute, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    We evaluated the efficacy of contrast-enhanced ultrasonography (CEUS) in detecting acute pyelonephritis (APN) using the rabbit kidney model and compared it with CT and MRI. This study was approved by the Institutional Review Board. In a total of 20 New Zealand White rabbits, APN was induced experimentally. CEUS, CT, and MRI were performed on the first, third, and seventh postoperative days. After imaging studies, the subjects were sacrificed and the pathological diagnosis of APN was confirmed in each animal by a pathologist. Imaging studies were obtained in eight animals, including eight CEUS, four computed tomography (CT), and four magnetic resonance imaging (MRI) images. CEUS depicted diffuse renal enlargement (7), diffuse heterogeneous parenchymal enhancement (6), and focal areas of decreased parenchymal enhancement (6). These findings were well correlated with the CT and MRI findings in five cases in which these studies were available. CT and MRI showed diffuse renal enlargement, diffuse heterogeneous parenchymal enhancement, focal areas of decreased parenchymal enhancement, focal contour bulging, and the finding of perinephric spread of infection. In a rabbit model, CEUS could depict the parenchymal lesions of APN similar to CT or MRI; however, it was limited in depicting the perinephric extension of inflammation.

  15. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  16. Dynamic contrast-enhanced CT appearances of the intraductal papillary neoplasms of the bile duct

    International Nuclear Information System (INIS)

    Song Fengxiang; Zhou Jianjun; Zeng Mengsu; Zhou Kangrong; Ding Yuqin; He Deming; Shi Yuxin; Zhou Jun

    2013-01-01

    Objective: To analyze the dynamic contrast-enhanced CT appearances of intraductal papillary neoplasms of the bile duct and improve its diagnostic accuracy. Methods: Sixteen patients with intraductal papillary neoplasms of the bile duct confirmed histopathologically after surgical operation underwent dynamic contrast-enhanced multi-detector row CT scans. All imaging data were reviewed and analyzed retrospectively in correlation with surgical and pathological findings. CT values of 38 well-visualized lesions in 12 of the 16 patients at the pre-contrast phase, arterial phase and venous phase were measured. Four of the 12 patients with 17 lesions had benign tumors, and 8 of the 12 patients with 21 lesions had malignant tumors. Comparisons of CT values at the three phases between the two groups were carried out using independent sample t test. The bile CT values were measured in these 12 cases, 40 normal volunteers, and 40 subjects with bile duct stones, and the Wilcoxon signed-rank test was applied to compare the bile CT values between tumor group and the normal group and between tumor group and the bile duct stone group. The diameters of the bile ducts proximal to and distal to tumors were also measured, and Fisher exact method was carried to analyze the data. Results: Lesions located at the left lobe in 8 out of the 16 patients, the right lobe in 1 case, both the left and right lobes in 1 case, the hepatic hilum in 1 case, the common bile duct in 3 cases, and both the right lobe and the common bile duct in 2 cases. Eleven lesions appeared as papillary masses, 3 as flat masses, 1 as mixed papillary and flat masses. In one case, tumor mass could not be definitely visualized, and only dilated bile ducts and stones were demonstrated. The mean CT values of the benign tumors were (25.8 ± 8.0), (37.7 ± 10.3) and (51.7 ± 17.1) HU respectively at pre-contrast phase, arterial phase, and venous phase, and the malignant tumors were (38.4 ± 10.2), (56.6 ± 18.0) and (68.4

  17. Experimental study of abdominal CT scanning exposal doses adjusted on the basis of pediatric abdominal perimeter

    International Nuclear Information System (INIS)

    Wei Wenzhou; Zhu Gongsheng; Zeng Lingyan; Yin Xianglin; Yang Fuwen; Liu Changsheng

    2006-01-01

    Objective: To optimize the abdominal helical CT scanning parameters in pediatric patients and to reduce its radiation hazards. Methods: 60 canines were evenly grouped into 4 groups on the basis of pediatric abdominal perimeter, scanned with 110,150,190 and 240 mAs, and their qualities of canine CT images were analyzed. 120 pediafric patients with clinic suspected abdominal diseases were divided into 4 groups on the basis of abdominal perimeter, scanned by optimal parameters and their image qualities were analyzed. Results: After CT exposure were reduced, the percentages of total A and B were 90.9 % and 92.0 % in experimental canines and in pediatric patients, respectively. Compared with conventional CT scanning, the exposure and single slice CT dose index weighted (CTDIw) were reduced to 45.8%-79.17%. Conclusion: By adjusted the pediatric helical CT parameters basedon the of pediatric abdominal perimeter, exposure of patient to the hazards of radiation is reduced. (authors)

  18. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET/CT

  19. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced

  20. Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI

    International Nuclear Information System (INIS)

    Giesel, F.L.; Kratochwil, C.; Mehndiratta, A.; Wulfert, S.; Moltz, J.H.; Zechmann, C.M.; Kauczor, H.U.; Haberkorn, U.; Ley, S.

    2012-01-01

    Purpose: We evaluated the rate of successful characterization of gastroenteropancreatic neuroendocrine tumors (NETs) present with an increased somatostatin receptor, comparing CE-CT with CE-MRI, each in correlation with DOTATOC-PET. Methods and materials: 8 patients with GEP-NET were imaged using CE-MRI (Gd-EOB-DTPA), CE-CT (Imeron 400) and DOTATOC-PET. Contrast-enhancement of normal liver-tissue and metastasis was quantified with ROI-technique. Tumor delineation was assessed with visual-score in blind-read-analysis by two experienced radiologists. Results: Out of 40 liver metastases in patients with NETs, all were detected by CE-MRI and the lesion extent could be adequately assessed, whereas CT failed to detect 20% of all metastases. The blind-read-score of CT in arterial and portal phase was median −0.65 and −1.4, respectively, and 2.7 for delayed-MRI. The quantitative ROI-analysis presented an improved contrast-enhancement-ratio with a median of 1.2, 1.6 and 3.3 for CE-CT arterial, portal-phase and delayed-MRI respectively. Conclusion: Late CE-MRI was superior to CE-CT in providing additionally morphologic characterization and exact lesion extension of hepatic metastases from neuroendocrine tumor detected with DOTATOC-PET. Therefore, late enhanced Gd-EOB-DTPA-MRI seems to be the adequate imaging modality for combination with DOTATOC-PET to provide complementary (macroscopic and molecular) tumor characterization in hepatic metastasized NETs

  1. Virtual CT-colonoscopy. Examination technique, limitations, and prospects

    International Nuclear Information System (INIS)

    Springer, P.; Dessl, A.; Giacomuzzi, S.M.; Stoehr, B.; Stoeger, A.; Bodner, G.; Buchberger, W.

    1997-01-01

    Virtual CT-colonoscopy is a post-processing method which allows for reconstruction of inner bowel surface structures from helical CT datasets. The reconstructed images simulate the views which are known from fiberoptic endoscopy. Since colorectal cancer is the second main cause of death in USA and Europe today and since recent screening recommendations are often ignored by the public, a non-invasive or minimal-invasive procedure for colonic evaluation would offer some benefits. Virtual CT-colonoscopy generally involves three essential steps: patient preparation with cleansing of the bowel and administration of an air enema, helical CT-examination by using appropriate scan parameters, and interactive 3D rendering of the volume dataset. Although recent studies have demonstrated that polypoid lesions of about 5 mm size are well detectable and although virtual colonoscopy offers many advantages over fiberoptic endoscopy, some technical and clinical limitations must still be noted. Thus, the current inability of virtual colonoscopy to provide texture and color leads to problems in identifying flat lesions; the presence of retained or adherent fecal matter may result to false positive diagnosis and collapsed segments of bowel may cause problems as they cannot subsequently be evaluated during image reconstruction. Virtual endoscopy is still in its infancy and further technical and clinical development are necessary. (orig./AJ) [de

  2. Conversion from mutual helicity to self-helicity observed with IRIS

    Science.gov (United States)

    Li, L. P.; Peter, H.; Chen, F.; Zhang, J.

    2014-10-01

    Context. In the upper atmosphere of the Sun observations show convincing evidence for crossing and twisted structures, which are interpreted as mutual helicity and self-helicity. Aims: We use observations with the new Interface Region Imaging Spectrograph (IRIS) to show the conversion of mutual helicity into self-helicity in coronal structures on the Sun. Methods: Using far UV spectra and slit-jaw images from IRIS and coronal images and magnetograms from SDO, we investigated the evolution of two crossing loops in an active region, in particular, the properties of the Si IV line profile in cool loops. Results: In the early stage two cool loops cross each other and accordingly have mutual helicity. The Doppler shifts in the loops indicate that they wind around each other. As a consequence, near the crossing point of the loops (interchange) reconnection sets in, which heats the plasma. This is consistent with the observed increase of the line width and of the appearance of the loops at higher temperatures. After this interaction, the two new loops run in parallel, and in one of them shows a clear spectral tilt of the Si IV line profile. This is indicative of a helical (twisting) motion, which is the same as to say that the loop has self-helicity. Conclusions: The high spatial and spectral resolution of IRIS allowed us to see the conversion of mutual helicity to self-helicity in the (interchange) reconnection of two loops. This is observational evidence for earlier theoretical speculations. Movie associated with Fig. 1 and Appendix A are available in electronic form at http://www.aanda.org

  3. Recurrent postoperative sciatica: Evaluation with MR imaging and enhanced CT

    International Nuclear Information System (INIS)

    Duvauferrier, R.; Frocain, L.; Husson, J.L.

    1987-01-01

    The authors prospectively compared MR imaging performed with a surface coil and CT performed with iodinated contrast agent enhancement in 50 patients with recurrent postoperative sciatica. Surgical decision was an objective measure of accuracy. Surgical treatment was selected for 27 patients. All 27 underwent MR imaging. The 15 patients who underwent CT/surgical treatment were included in the 27 indications of SCMR. All predictions based on MR imaging findings were confirmed at surgery. There were 25 recurrent disk herniations, including five with scar tissue, and two disk herniations above or below the level of the diskectomy. In the 12 patients with scar tissue detected on CT there were seven recurrent disk hernitions, four recurrent disk herniations with scar tissue, and one disk herniation below the level of the diskectomy

  4. Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements.

    Science.gov (United States)

    Ascenti, Giorgio; Mileto, Achille; Krauss, Bernhard; Gaeta, Michele; Blandino, Alfredo; Scribano, Emanuele; Settineri, Nicola; Mazziotti, Silvio

    2013-08-01

    To compare the diagnostic accuracy of iodine quantification and standard enhancement measurements in distinguishing enhancing from nonenhancing renal masses. The Institutional Review Board approved this retrospective study conducted from data found in institutional patient databases and archives. Seventy-two renal masses were characterised as enhancing or nonenhancing using standard enhancement measurements (in HU) and iodine quantification (in mg/ml). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of standard enhancement measurements and iodine quantification were calculated from χ (2) tests of contingency with histopathology or imaging follow-up as the reference standard. Difference in accuracy was assessed by means of McNemar analysis. Sensitivity, specificity, PPV, NPV and diagnostic accuracy for standard enhancement measurements and iodine quantification were 77.7 %, 100 %, 100 %, 81.8 %, 89 % and 100 %, 94.4 %, 94.7, 100 % and 97 %, respectively. The McNemar analysis showed that the accuracy of iodine quantification was significantly better (P < 0.001) than that of standard enhancement measurements. Compared with standard enhancement measurements, whole-tumour iodine quantification is more accurate in distinguishing enhancing from nonenhancing renal masses. • Enhancement of renal lesions is important when differentiating benign from malignant tumours. • Dual-energy CT offers measurement of iodine uptake rather than mere enhancement values. • Whole-tumour iodine quantification seems more accurate than standard CT enhancement measurements.

  5. Follow-up after stent insertion in the tracheobronchial tree: role of helical computed tomography in comparison with fiberoptic bronchoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ferretti, G.R.; Kocier, M.; Calaque, O.; Coulomb, M. [Service Central de Radiologie et Imagerie Medicale, INSERM EMI 9924, CHU, BP 217, 38043, Grenoble Cedex 9 (France); Arbib, F.; Pison, C. [Departement de Medecine Aigue Specialisee (DMAS), CHU Grenoble, CHU, BP 217, 38043, Grenoble Cedex 9 (France); Righini, C. [Service d' Oto Rhino Laryngologie, CHU Grenoble, BP 217, 38043, Grenoble Cedex 9 (France)

    2003-05-01

    The aim of this study was to compare helical CT with fiberoptic bronchoscopy findings to appraise the medium-term results of proximal-airways stenting. Twenty-five patients with 28 endobronchial metallic stents inserted for local advanced malignancy (n=13) or benign diseases (n=12) underwent follow-up CT from 3 days to 50 months (mean 8 months). All studies were obtained using helical CT with subsequent multiplanar reformation and three-dimensional reconstruction including virtual bronchoscopy. The location, shape, and patency of stents and adjacent airway were assessed. The results of CT were compared with the results of fiberoptic bronchoscopy obtained with a mean delay of 2.5 days (SD 9 days) after CT scan. Twelve stents (43%) remained in their original position, patent and without deformity. Sixteen stents were associated with local complications: migration (n=6); external compression with persistent stenosis (n=4); local recurrence of malignancy (n=4); fracture (n=1); and non-congruence between the airway and the stent (n=1). The CT demonstrated all the significant abnormalities demonstrated at fiberoptic bronchoscopy except two moderate stenoses (20%) related to granulomata at the origin of the stent. Ten of 14 stents inserted for benign conditions were without complications as compared with 2 of 14 in malignant conditions (p=0.008). Computed tomography is an accurate noninvasive method for evaluating endobronchial stents. The CT is a useful technique for follow-up of patients who have undergone endobronchial stenting. (orig.)

  6. Follow-up after stent insertion in the tracheobronchial tree: role of helical computed tomography in comparison with fiberoptic bronchoscopy

    International Nuclear Information System (INIS)

    Ferretti, G.R.; Kocier, M.; Calaque, O.; Coulomb, M.; Arbib, F.; Pison, C.; Righini, C.

    2003-01-01

    The aim of this study was to compare helical CT with fiberoptic bronchoscopy findings to appraise the medium-term results of proximal-airways stenting. Twenty-five patients with 28 endobronchial metallic stents inserted for local advanced malignancy (n=13) or benign diseases (n=12) underwent follow-up CT from 3 days to 50 months (mean 8 months). All studies were obtained using helical CT with subsequent multiplanar reformation and three-dimensional reconstruction including virtual bronchoscopy. The location, shape, and patency of stents and adjacent airway were assessed. The results of CT were compared with the results of fiberoptic bronchoscopy obtained with a mean delay of 2.5 days (SD 9 days) after CT scan. Twelve stents (43%) remained in their original position, patent and without deformity. Sixteen stents were associated with local complications: migration (n=6); external compression with persistent stenosis (n=4); local recurrence of malignancy (n=4); fracture (n=1); and non-congruence between the airway and the stent (n=1). The CT demonstrated all the significant abnormalities demonstrated at fiberoptic bronchoscopy except two moderate stenoses (20%) related to granulomata at the origin of the stent. Ten of 14 stents inserted for benign conditions were without complications as compared with 2 of 14 in malignant conditions (p=0.008). Computed tomography is an accurate noninvasive method for evaluating endobronchial stents. The CT is a useful technique for follow-up of patients who have undergone endobronchial stenting. (orig.)

  7. Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical Tomotherapy

    International Nuclear Information System (INIS)

    Yang, Claus; Liu Tianxiao; Jennelle, Richard L.; Ryu, Janice K.; Vijayakumar, Srinivasan; Purdy, James A.; Chen, Allen M.

    2010-01-01

    The purpose of this study was to demonstrate the potential utility of megavoltage fan-beam computed tomography (MV-FBCT) for treatment planning in a patient undergoing helical tomotherapy for nasopharyngeal carcinoma in the presence of extensive dental artifact. A 28-year-old female with locally advanced nasopharyngeal carcinoma presented for radiation therapy. Due to the extensiveness of the dental artifact present in the oral cavity kV-CT scan acquired at simulation, which made treatment planning impossible on tomotherapy planning system, MV-FBCT imaging was obtained using the HI-ART tomotherapy treatment machine, with the patient in the treatment position, and this information was registered with her original kV-CT scan for the purposes of structure delineation, dose calculation, and treatment planning. To validate the feasibility of the MV-FBCT-generated treatment plan, an electron density CT phantom (model 465, Gammex Inc., Middleton, WI) was scanned using MV-FBCT to obtain CT number to density table. Additionally, both a 'cheese' phantom (which came with the tomotherapy treatment machine) with 2 inserted ion chambers and a generic phantom called Quasar phantom (Modus Medical Devices Inc., London, ON, Canada) with one inserted chamber were used to confirm dosimetric accuracy. The MV-FBCT could be used to clearly visualize anatomy in the region of the dental artifact and provide sufficient soft-tissue contrast to assist in the delineation of normal tissue structures and fat planes. With the elimination of the dental artifact, the MV-FBCT images allowed more accurate dose calculation by the tomotherapy system. It was confirmed that the phantom material density was determined correctly by the tomotherapy MV-FBCT number to density table. The ion chamber measurements agreed with the calculations from the MV-FBCT generated phantom plan within 2%. MV-FBCT may be useful in radiation treatment planning for nasopharyngeal cancer patients in the setting of extensive

  8. Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Harmon, Joseph F. Jr.; Langen, Katja M.; Willoughby, Twyla R.; Wagner, Thomas H.; Kupelian, Patrick A.

    2005-01-01

    Helical tomotherapy is an innovative means of delivering IGRT and IMRT using a device that combines features of a linear accelerator and a helical computed tomography (CT) scanner. The HI-ART II can generate CT images from the same megavoltage x-ray beam it uses for treatment. These megavoltage CT (MVCT) images offer verification of the patient position prior to and potentially during radiation therapy. Since the unit uses the actual treatment beam as the x-ray source for image acquisition, no surrogate telemetry systems are required to register image space to treatment space. The disadvantage to using the treatment beam for imaging, however, is that the physics of radiation interactions in the megavoltage energy range may force compromises between the dose delivered and the image quality in comparison to diagnostic CT scanners. The performance of the system is therefore characterized in terms of objective measures of noise, uniformity, contrast, and spatial resolution as a function of the dose delivered by the MVCT beam. The uniformity and spatial resolutions of MVCT images generated by the HI-ART II are comparable to that of diagnostic CT images. Furthermore, the MVCT scan contrast is linear with respect to the electron density of material imaged. MVCT images do not have the same performance characteristics as state-of-the art diagnostic CT scanners when one objectively examines noise and low-contrast resolution. These inferior results may be explained, at least partially, by the low doses delivered by our unit; the dose is 1.1 cGy in a 20 cm diameter cylindrical phantom. In spite of the poorer low-contrast resolution, these relatively low-dose MVCT scans provide sufficient contrast to delineate many soft-tissue structures. Hence, these images are useful not only for verifying the patient's position at the time of therapy, but they are also sufficient for delineating many anatomic structures. In conjunction with the ability to recalculate radiotherapy doses on

  9. Helicity, Reconnection, and Dynamo Effects

    International Nuclear Information System (INIS)

    Ji, Hantao

    1998-01-01

    The inter-relationships between magnetic helicity, magnetic reconnection, and dynamo effects are discussed. In laboratory experiments, where two plasmas are driven to merge, the helicity content of each plasma strongly affects the reconnection rate, as well as the shape of the diffusion region. Conversely, magnetic reconnection events also strongly affect the global helicity, resulting in efficient helicity cancellation (but not dissipation) during counter-helicity reconnection and a finite helicity increase or decrease (but less efficiently than dissipation of magnetic energy) during co-helicity reconnection. Close relationships also exist between magnetic helicity and dynamo effects. The turbulent electromotive force along the mean magnetic field (alpha-effect), due to either electrostatic turbulence or the electron diamagnetic effect, transports mean-field helicity across space without dissipation. This has been supported by direct measurements of helicity flux in a laboratory plasma. When the dynamo effect is driven by electromagnetic turbulence, helicity in the turbulent field is converted to mean-field helicity. In all cases, however, dynamo processes conserve total helicity except for a small battery effect, consistent with the observation that the helicity is approximately conserved during magnetic relaxation

  10. Ventilation imaging of the paranasal sinuses using xenon-enhanced dynamic single-energy CT and dual-energy CT: a feasibility study in a nasal cast

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Helck, Andreas D.; Reiser, Maximilian F.; Johnson, Thorsten R.C. [Ludwig Maximilians University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Moeller, Winfried; Eickelberg, Oliver [Institute for Lung Biology and Disease (iLBD) and Comprehensive Pneumology Center (CPC), Helmholtz Zentrum Muenchen, Neuherberg, Munich (Germany); Becker, Sven [Ludwig-Maximilians-Universitaet, Department of Otorhinolaryngology - Head and Neck Surgery, Munich (Germany); Schuschnig, Uwe [Pari Pharma GmbH, Graefelfing (Germany)

    2012-10-15

    To show the feasibility of dual-energy CT (DECT) and dynamic CT for ventilation imaging of the paranasal sinuses in a nasal cast. In a first trial, xenon gas was administered to a nasal cast with a laminar flow of 7 L/min. Dynamic CT acquisitions of the nasal cavity and the sinuses were performed. This procedure was repeated with pulsating xenon flow. Local xenon concentrations in the different compartments of the model were determined on the basis of the enhancement levels. In a second trial, DECT measurements were performed both during laminar and pulsating xenon administration and the xenon concentrations were quantified directly. Neither with dynamic CT nor DECT could xenon-related enhancement be detected in the sinuses during laminar airflow. Using pulsating flow, dynamic imaging showed a xenon wash-in and wash-out in the sinuses that followed a mono-exponential function with time constants of a few seconds. Accordingly, DECT revealed xenon enhancement in the sinuses only after pulsating xenon administration. The feasibility of xenon-enhanced DECT for ventilation imaging was proven in a nasal cast. The superiority of pulsating gas flow for the administration of gas or aerosolised drugs to the paranasal sinuses was demonstrated. (orig.)

  11. Differences in MRI findings in cases showing ring-enhancement on a CT scan

    International Nuclear Information System (INIS)

    Tokiwa, Kaichi; Hashimoto, Takashi; Miyasaka, Yoshio; Yada, Kenzoh; Kan, Shinichi; Takagi, Hiroshi.

    1990-01-01

    It is sometimes difficult to differentiate between a brain abscess and a tumor, for both show ring-enhancement on a CT scan. The present authors have studied the benefit of MRI for the differential diagnosis of these two lesions. The subjects of this study were 6 cases of brain abscess and 10 cases of brain tumor, all of them showing ring-enhancement on a CT scan. The MRI findings were compared with those of the CT scan taken at almost the same time, especially focussing on the difference in the ring-enhancement. In 5 out of the 6 cases of brain abscess, T 2 -weighted MRI demonstrated a comparatively thin and homogeneous low-intensity, round rim. In the cases of brain tumor, however, none of the cases demonstrated this typical low-intensity, round rim; rather, in them the rim was thick and irregular. The authors can conclude that those MRI findings can serve as important differential diagnostic findings between brain abscess and tumor; also, MRI may be used as a landmark for terminating the administration of antibiotics in cases of brain abscess. (author)

  12. Usefulness of preoperative chest multidetector CT for evaluation of breast cancer: comparison with breast MRI

    International Nuclear Information System (INIS)

    Chang, Yun Woo; Kim, Dong Hun; Lee, Min Hyuk

    2005-01-01

    To evaluate the efficacy of chest multidetector-row helical computed tomography (MDCT) in detecting breast cancer in preoperative metastasis work-ups and to assess the accuracy of MDCT compared with magnetic resonance imaging (MRI). MDCT were performed on 69 consecutive patients with 94 lesions of histologically proven breast cancer. Retrospectively, two radiologists performed a blind review of the MDCT images for margin, shape, mass enhancement pattern and the enhancing distribution of non-mass lesions with consensus. CT attenuation values were measured in the average HU on pre-enhancing and enhanced CT in gland, fat, muscle, and in masses with the largest region of interest (ROI). MDCT finding were analyzed and compared with breast MRI. Of the 91 breast lesions detected on MDCT, 64 were mass lesions and 24 were non-mass lesions on enhancement, 86 lesions were malignant and 5 were benign. Three pathologically proven malignant masses were not detected on MDCT. Positive predictive value, false positive rate and false negative rate were 94.5%, 5.3%, 3.2% respectively. The highly predictive features for malignancy were a spiculated or irregular margin, an irregular of round shape, and a heterogeneously or rim enhanced mass. Another highly predictive feature for malignancy was linear or segmentally distributed enhancing non-mass lesions. The CT values of masses in pre-enhanced scans were 38.6 ± 7.9 HU; these values increased to 110.9 ± 26.6 HU after contrast injection (90 sec). The attenuation values from enhancing CT of malignant lesions were significantly higher than those of non-enhancing lesions. The depiction of enhancing masses on MDCT compared with MR imaging were 88.6%. The extension of malignancy were equally well correlated MDCT with MR imaging. The diagnostic value of chest MDCT for preoperative staging is comparable with MR imaging for the detection and extension of lesions. Therefore, chest MDCT of breast cancer can add to the information obtained from

  13. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    International Nuclear Information System (INIS)

    Jensen, Nikolaj K. G.; Stewart, Errol; Lock, Michael; Fisher, Barbara; Kozak, Roman; Chen, Jeff; Lee, Ting-Yim; Wong, Eugene

    2014-01-01

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT

  14. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Nikolaj K. G., E-mail: nkyj@regionsjaelland.dk [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Stewart, Errol [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Lock, Michael; Fisher, Barbara [Radiation Oncology, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Kozak, Roman [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Chen, Jeff [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Lee, Ting-Yim [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Wong, Eugene [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Department of Physics and Astronomy, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-05-15

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT.

  15. Contrast-enhanced CT and MRI findings of atypical hepatic Echinococcus alveolarisinfestation

    International Nuclear Information System (INIS)

    Etlik, Oemer; Arslan, Halil; Harman, Mustafa; Temizoez, Osman; Bay, Ali; Koesem, Mustafa; Dogan, Ekrem

    2005-01-01

    Diagnosis of liver infestation by Echinococcus alveolaris(EA) is based on serological and radiological findings. In this report, we present a 15-year-old girl with atypical hepatic EA infestation showing central punctate calcifications and contrast enhancement on the portal and late phases of CT and MRI. CT showed a hypodense mass involving more than half of the liver with prominent central calcifications. MRI revealed hypointense signal of the infiltrative mass on both T1- and T2-weighted images. Contrast enhancement is a unique finding in hepatic EA infestation that may cause difficulties with diagnosis. MRI may provide invaluable information in the diagnosis of EA infestation of the liver, either by disclosing the infiltrative pattern of infestation without significant effect to vascular structures, or by the signal characteristics. (orig.)

  16. Contrast-enhanced CT and MRI findings of atypical hepatic Echinococcus alveolarisinfestation

    Energy Technology Data Exchange (ETDEWEB)

    Etlik, Oemer; Arslan, Halil; Harman, Mustafa; Temizoez, Osman [Yuzuncu Yil University Faculty of Medicine, Department of Radiology, Van (Turkey); Bay, Ali [Yuzuncu Yil University Faculty of Medicine, Department of Paediatrics, Van (Turkey); Koesem, Mustafa [Yuzuncu Yil University Faculty of Medicine, Department of Pathology, Van (Turkey); Dogan, Ekrem [Yuzuncu Yil University Faculty of Medicine, Department of Internal Medicine, Van (Turkey)

    2005-05-01

    Diagnosis of liver infestation by Echinococcus alveolaris(EA) is based on serological and radiological findings. In this report, we present a 15-year-old girl with atypical hepatic EA infestation showing central punctate calcifications and contrast enhancement on the portal and late phases of CT and MRI. CT showed a hypodense mass involving more than half of the liver with prominent central calcifications. MRI revealed hypointense signal of the infiltrative mass on both T1- and T2-weighted images. Contrast enhancement is a unique finding in hepatic EA infestation that may cause difficulties with diagnosis. MRI may provide invaluable information in the diagnosis of EA infestation of the liver, either by disclosing the infiltrative pattern of infestation without significant effect to vascular structures, or by the signal characteristics. (orig.)

  17. Clinical application of multi-slice helical CT volumetric scanning in lumber spine

    International Nuclear Information System (INIS)

    Wang Ling; Ge Yinghui; Zhu Shaocheng; Zhang Ming; Cheng Tianming; Lei Zhidan; Lv Chuanjian; Sun Xiaoping; Wu Minghui; Guo Ying; Ma Qianli; Wen Zeying

    2008-01-01

    Objective: To evaluate the clinical application value of multi-slice helical CT volumetric (VH) scanning in lumber spine. Methods: One thousand of patients with back and leg pain who underwent CT examinations were selected as subjects. We simulated the traditional protocol of single-slice(SS) discrete scanning for L3/4, L4/5, and L5/S1 intervertebral discs. The VH scanning mode was performed with 120 kV, 210 mAs, pitch of 1.5 and coverage of 97.5 mm. The simulated SS scanning mode was performed with 120 kV, 240 mAs and coverage of 45.0 mm. The diagnostic outcomes and the radiation doses were compared between the two scanning modes. Two groups doctors observed ten terms, including the osseous spinal stenosis, narrowed intervertebral space and so on in two scanning modes respectively. Then consistency analysis of the data was carded out. Results: The VH scanning mode showed far more features than the SS mode. The detection rates of the VH mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, narrowed lateral recess, vertebral lesion, hypertrophy of L5 transverse process, abnormal direction of facet, facet degeneration, lumbar spondyloschisis, and paraspinal soft tissue were 11.8% (n=118), 38.5% (n=385), 9.3% (n=93), 46.8% (n=468), 31.4% (n=314), 5.7% (n= 57), 25.4% (n=254), 49.7% (n=497), 9.9% (n=99), and 0.6% (n=6) respectively, while the detection rates of the SS mode in ten terms were 5.6% (n=56), 0, 0.6% (n=6), 27.9% (n=279), 22.4% (n=224), 1.2% (n=12), 16.7% (n=167), 37.2% (n=372), 0.5% (n=5), and 0.2% (n=2) respectively. The difference between the two groups had statistically significance (average P 0.05). The detection rates of the VH mode were higher than the SS mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, lumbar spondyloschisis, being 6.2% (n=62), 38.5% (n=385), 8.7% (n=87), and 9.4% (n=94), respectively. In addition, VH mode only partially showed the articular

  18. Primary pulmonary low-grade angiosarcoma characterized by mismatch between {sup 18}F-FDG FET and dynamic contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Eun Young; Lee, Ho Yun; Han, Joung Ho; Choi, Joon Young [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    We report a rare case of primary pulmonary low-grade angiosarcoma on dynamic contrast-enhanced CT and {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT imaging. A 38-year-old, asymptomatic woman was hospitalized because of an abnormality on chest radiography. A dynamic contrast-enhanced chest CT showed a 1.2 cm-sized irregular-margined nodule with strong and persistent enhancement in the right lower lobe. The lesion had low metabolic activity on an {sup 18}F-FDG PET/CT scan. The patient underwent a wedge resection for the lesion, and pathology revealed a primary pulmonary low-grade angiosarcoma.

  19. Association of achondroplasia with Down syndrome: difficulty in prenatal diagnosis by sonographic and 3-D helical computed tomographic analyses.

    Science.gov (United States)

    Kaga, Akimune; Murotsuki, Jun; Kamimura, Miki; Kimura, Masato; Saito-Hakoda, Akiko; Kanno, Junko; Hoshi, Kazuhiko; Kure, Shigeo; Fujiwara, Ikuma

    2015-05-01

    Achondroplasia and Down syndrome are relatively common conditions individually. But co-occurrence of both conditions in the same patient is rare and there have been no reports of fetal analysis of this condition by prenatal sonographic and three-dimensional (3-D) helical computed tomography (CT). Prenatal sonographic findings seen in persons with Down syndrome, such as a thickened nuchal fold, cardiac defects, and echogenic bowel were not found in the patient. A prenatal 3-D helical CT revealed a large head with frontal bossing, metaphyseal flaring of the long bones, and small iliac wings, which suggested achondroplasia. In a case with combination of achondroplasia and Down syndrome, it may be difficult to diagnose the co-occurrence prenatally without typical markers of Down syndrome. © 2014 Japanese Teratology Society.

  20. Advances in the implementation of helical tomotherapy-based total marrow irradiation with a novel field junction technique

    Energy Technology Data Exchange (ETDEWEB)

    Zeverino, Michele, E-mail: michele.zeverino@istge.it [Medical Physics Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy); Agostinelli, Stefano; Taccini, Gianni; Cavagnetto, Francesca; Garelli, Stefania; Gusinu, Marco [Medical Physics Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy); Vagge, Stefano; Barra, Salvina; Corvo, Renzo [Radiation Oncology Department, IRCCS, Istituto Nazionale per la Ricerca sul cancro, Genoa (Italy)

    2012-10-01

    Given the limitations in the travel ability of the helical tomotherapy (HT) couch, total marrow irradiation (TMI) has to be split in 2 segments, with the lower limbs treated with feet first orientation. The aim of this work is to present a planning technique useful to reduce the dose inhomogeneity resulting from the matching of the 2 helical dose distributions. Three HT plans were generated for each of the 18 patients enrolled. Upper TMI (UTMI) and lower TMI (LTMI) were planned onto the whole-body computed tomography (CT) and on the lower-limb CT, respectively. A twin lower TMI plan (tLTMI) was designed on the whole-body CT. Agreement between LTMI and tLTMI plans was assessed by computing for each dose-volume histogram (DVH) structure the {gamma} index scored with 1% of dose and volume difference thresholds. UTMI and tLTMI plans were summed together on the whole-body CT, enabling the evaluation of dose inhomogeneity. Moreover, a couple of transition volumes were used to improve the dose uniformity in the abutment region. For every DVH, a number of points >99% passed the {gamma} analysis, validating the method used to generate the twin plan. The planned dose inhomogeneity at the junction level resulted within {+-}10% of the prescribed dose. Median dose reduction to organs at risk ranged from 30-80% of the prescribed dose. Mean conformity index was 1.41 (range 1.36-1.44) for the whole-body target. The technique provided a 'full helical' dose distribution for TMI treatments, which can be considered effective only if the dose agreement between LTMI and tLTMI plans is met. The planning of TMI with HT for the whole body with adequate dose homogeneity and conformity was shown to be feasible.

  1. Persistent adrenal enhancement may be the earliest CT sign of significant hypovolaemic shock

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, S.C.W.; Lee, R.; Tung, H.K.S.; Chan, F.L

    2003-04-01

    AIM: To report two cases of intense and persistent adrenal enhancement on computed tomography (CT) examinations of the abdomen. MATERIALS AND METHODS: Two patients presented with septic shock, one due to pyogenic liver abscess and the other strangulated obturator hernia with gangrenous bowel. Both patients were resuscitated with fluid before undergoing unenhanced and enhanced CT. RESULTS: In both patients intravascular volume was not reduced as evident by normal calibre of the aorta and inferior vena cava. One patient had abnormal enhancement pattern in the liver and kidneys, suggesting hypoperfusion. The other patient had normal enhancement pattern of the other abdominal viscera. Both patient subsequently died with multi-organ failure. CONCLUSION: We propose that adrenal enhancement may be a sign of hyperperfusion in early stage of shock due to the crucial role of the adrenal glands in this clinical situation. This may not persist with further circulatory compromise due to vasoconstriction. If confirmed, its recognition has potential value of identifying a therapeutic window before irreversible shock set in.

  2. Osmotic blood-brain barrier modification: clinical documentation by enhanced CT scanning and/or radionuclide brain scanning

    International Nuclear Information System (INIS)

    Neuwelt, E.A.; Specht, H.D.; Howieson, J.; Haines, J.E.; Bennett, M.J.; Hill, S.A.; Frenkel, E.P.

    1983-01-01

    Results of initial clinical trials of brain tumor chemotherapy after osmotic blood-brain barrier disruption are promising. In general, the procedure is well tolerated. The major complication has been seizures. In this report, data are presented which indicate that the etiology of these seizures is related to the use of contrast agent (meglumine iothalamate) to monitor barrier modification. A series of 19 patients underwent a total of 85 barrier modification procedures. Documentation of barrier disruption was monitored by contrast-enhanced computed tomographic (CT) scanning, radionuclide brain scanning, or a combination of both techniques. In 56 procedures (19 patients) monitored by enhanced CT, seizures occurred a total of 10 times in eight patients. Twenty-three barrier modification procedures (in nine of these 19 patients) documented by nuclear brain scans alone, however, resulted in only one focal motor seizure in each of two patients. In eight of the 19 patients who had seizures after barrier disruption and enhanced CT scan, four subsequently had repeat procedures monitored by radionuclide scan alone. In only one of these patients was further seizure activity noted; a single focal motor seizure was observed. Clearly, the radionuclide brain scan does not have the sensitivity and spatial resolution of enhanced CT, but at present it appears safer to monitor barrier modification by this method and to follow tumor growth between barrier modifications by enhanced CT. Four illustrative cases showing methods, problems, and promising results are presented

  3. New frontiers in CT imaging of airway disease

    International Nuclear Information System (INIS)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine; Fetita, Catalin; Preteux, Francoise; Brauner, Michel W.; Lenoir, Stephane

    2002-01-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  4. Collateral ventilation to congenital hyperlucent lung lesions assessed on xenon-enhanced dynamic dual-energy CT: an initial experience.

    Science.gov (United States)

    Goo, Hyun Woo; Yang, Dong Hyun; Kim, Namkug; Park, Seung Il; Kim, Dong Kwan; Kim, Ellen Ai-Rhan

    2011-01-01

    We wanted to evaluate the resistance to collateral ventilation in congenital hyperlucent lung lesions and to correlate that with the anatomic findings on xenon-enhanced dynamic dual-energy CT. Xenon-enhanced dynamic dual-energy CT was successfully and safely performed in eight children (median age: 5.5 years, 4 boys and 4 girls) with congenital hyperlucent lung lesions. Functional assessment of the lung lesions on the xenon map was done, including performing a time-xenon value curve analysis and assessing the amplitude of xenon enhancement (A) value, the rate of xenon enhancement (K) value and the time of arrival value. Based on the A value, the lung lesions were categorized into high or low (A value > 10 Hounsfield unit [HU]) resistance to collateral ventilation. In addition, the morphologic CT findings of the lung lesions, including cyst, mucocele and an accessory or incomplete fissure, were assessed on the weighted-average CT images. The xenon-enhanced CT radiation dose was estimated. Five of the eight lung lesions were categorized into the high resistance group and three lesions were categorized into the low resistance group. The A and K values in the normal lung were higher than those in the low resistance group. The time of arrival values were delayed in the low resistance group. Cysts were identified in five lesions, mucocele in four, accessory fissure in three and incomplete fissure in two. Either cyst or an accessory fissure was seen in four of the five lesions showing high resistance to collateral ventilation. The xenon-enhanced CT radiation dose was 2.3 ± 0.6 mSv. Xenon-enhanced dynamic dual-energy CT can help visualize and quantitate various degrees of collateral ventilation to congenital hyperlucent lung lesions in addition to assessing the anatomic details of the lung.

  5. Hepatic scar in a case of healed candidiasis showing prolonged enhancement on CT

    Energy Technology Data Exchange (ETDEWEB)

    Itai, Yuji; Yashiro, Naobumi

    1987-08-01

    A patient with acute myelocytic leukemia recovering from hepatic candidiasis after long-term administration of amphotericin B had large scar in the liver which showed prominent prolonged enhancement on postcontrast CT. Prolonged enhancement can occur in regions other than hepatic masses.

  6. Chondroitin sulfate iron colloid-enhanced MR imaging in patients with hepatocellular carcinoma. Comparison with CT during arterial portography

    Energy Technology Data Exchange (ETDEWEB)

    Kamba, Masayuki [Dept. of Radiology, Tottori Univ., Yonago (Japan); Suto, Y. [Dept. of Radiology, Tottori Univ., Yonago (Japan); Kato, T. [Dept. of Radiology, Tottori Univ., Yonago (Japan)

    1994-11-01

    Chondroitin sulfate iron colloid (CSIC) was used as an MR contrast agent for the detection of hepatocellular carcinoma (HCC). The findings of 25 surgically confirmed HCCs in 19 patients were retrospectively analyzed. T1-, T2- and proton density-weighted spin echo MR images were obtained before and after i.v. injection of 23.6 {mu}M Fe/kg of CSIC. Unenhanced and CSIC-enhanced MR images and images obtained by CT during arterial protography (CT-AP) were correlated with surgical pathology findings. The sensitivities of CSIC-enhanced and unenhanced MR imaging, and CT-AP were 92%, 80%, and 88%, respectively. No significant differences were noted. Portal flow abnormalities demonstrated by CT-AP did not affect the detection of HCC by CSIC-enhanced MR imaging. CSIC-enhancement at MR imaging was a disadvantage in the detection of lesions less than 1 cm in diameter. CSIC-enhanced MR imaging is a supplemental method for the detection of HCC. (orig.).

  7. Application of Super-Resolution Convolutional Neural Network for Enhancing Image Resolution in Chest CT.

    Science.gov (United States)

    Umehara, Kensuke; Ota, Junko; Ishida, Takayuki

    2017-10-18

    In this study, the super-resolution convolutional neural network (SRCNN) scheme, which is the emerging deep-learning-based super-resolution method for enhancing image resolution in chest CT images, was applied and evaluated using the post-processing approach. For evaluation, 89 chest CT cases were sampled from The Cancer Imaging Archive. The 89 CT cases were divided randomly into 45 training cases and 44 external test cases. The SRCNN was trained using the training dataset. With the trained SRCNN, a high-resolution image was reconstructed from a low-resolution image, which was down-sampled from an original test image. For quantitative evaluation, two image quality metrics were measured and compared to those of the conventional linear interpolation methods. The image restoration quality of the SRCNN scheme was significantly higher than that of the linear interpolation methods (p < 0.001 or p < 0.05). The high-resolution image reconstructed by the SRCNN scheme was highly restored and comparable to the original reference image, in particular, for a ×2 magnification. These results indicate that the SRCNN scheme significantly outperforms the linear interpolation methods for enhancing image resolution in chest CT images. The results also suggest that SRCNN may become a potential solution for generating high-resolution CT images from standard CT images.

  8. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  9. The value of contrast-enhanced 64-row CT in differentiating benign from malignant serous ovarian neoplasms

    International Nuclear Information System (INIS)

    Dong Tianfa; Wu Meixian; Zhang Jiayun; Song Ting

    2009-01-01

    Objective: To assess the diagnostic value of contrast-enhanced 64-row CT scanning in deciding benign or malignant serous ovarian tumors. Methods: Fifty-eight cases of serous ovarian tumors proved pathologically were reviewed, including 25 malignant tumors, 25 benign, 8 borderline tumors. All patients underwent 64-row CT scanning, including plain scanning and contrast-enhance scanning. The tumors' shape, density, blood supply and enhancement features were evaluated. Results: Twenty-five cases of benign serous cystic adenoma were mostly unicameral, and showed a moderate mural enhancement only in 4 cases (16%) due to chronic pelvic infection and the others (21/25, 84%) had no of slight enhancement. Malignant tumors were cystic-solid mass with unclear margin, irregular shape and septa. Twenty-two cases of serous cystadenocarcinoma out of 25 cases (88%) appeared obvious enhancement and other 3 cases no enhancement. And 7 cases out of 8 (87.5%) borderlined serous cystadenomas showed different enhancement patterns. Conclusion: Benign ovarian serous neoplasms were mostly unicameral and no strong mural enhancement, suggesting a lack of blood supply. While, there were obvious enhancement in the ovarian serous cystadenocarcinoma and borderline serous cystadenoma with malignant potential. The 64-row CT is helpful for differentiating the nature of the serous ovarian neoplasm. (authors)

  10. Hepatic scar in a case of healed candidiasis showing prolonged enhancement on CT

    International Nuclear Information System (INIS)

    Itai, Yuji; Yashiro, Naobumi

    1987-01-01

    A patient with acute myelocytic leukemia recovering from hepatic candidiasis after long-term administration of amphotericin B had large scar in the liver which showed prominent prolonged enhancement on postcontrast CT. Prolonged enhancement can occur in regions other than hepatic masses. (author)

  11. Pulmonary CT angiography: optimization of contrast enhancement technique

    International Nuclear Information System (INIS)

    Ma Lianju; Tang Guangjian; Fu Jiazhen

    2012-01-01

    Objective: To derive and evaluate the formula of exactly calculating the contrast dosage used during pulmonary CT angiography (CTPA). Methods: Time density curves in 27 patients who underwent CTPA were collected and analyzed,the formula for calculating contrast dosage during CTPA was derived. 68 patients suspected of pulmonary embolism (PE) clinically but no PE on CTPA were divided randomly into group A, with bolus tracing technique (n=26), and group B, with small dose injection contrast test (SDCT) (n=42). The CT values of the right main pulmonary artery (RMPA), right upper pulmonary vein (RUPV), right posterior basal PA, right lower PV (RLPV) and the aorta were calculated. The total contrast dosage and the hard beam artifact in the SVC were compared between the two groups.Student's t test, Chi-square test and Mann-Whitney U test were used. Results: The ratio of the time from starting injection to enhancement peak of caudal end of SVC and the time to enhancement peak of the main pulmonary trunk was 0.65 ±0.09 (about 2/3), the formula for contrast dosage calculation was derived as (DTs/3 + STs/2) FR ml/s. The CT values of RMPA and RLPA between the two groups [(301 ±117), (329 ± 122) and (283 ±95), (277 ±98) HU respectively] were not significantly different (t=1.060, P=0.292; t=2.056, P=0.044), but the differences of CT values in the paired PA and PV between the two groups (median were 22.5, 58.0 and 170.5, 166.5 HU respectively) were significant (U=292, P=0.001 and U=325, P=0.005), contrast artifact of the SVC (grade 1-3) in group B (n=34, 7, 1 respectively) was significantly less than in group A (n=11, 10, 5 respectively, χ 2 =10.714, P=0.002), the contrast dosage injected in group A was ( 87.6 ± 7.3) ml, and in group B was (40.0 ±5.4) ml (P<0.01). Conclusion: CTPA with SDCT technique is superior to that with conventional bolus tracing technique regarding contrast dosage and contrast artifact in the SVC. (authors)

  12. The relationship between contrast enhancement on CT and cerebral vasospasm in patient with subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Tazawa, Toshiaki; Mizukami, Masahiro; Kawase, Takeshi; Usami, Takashi; Togashi, Osamu

    1982-01-01

    Sixty patients with a single rupture of an aneurysm were subjected to study. Contrast enhanced CT (CECT) was performed by intravenous infusion of 100 ml of 60% meglumine iothalamate in 10 minutes. Post-contrast CT scans were repeated serially just after infusion, 15 minutes and 30 minutes later. Prominent increase in density in the region of the circle of Willis and its branches 30 minutes after infusion was considered as remarkable enhancement. In 17 (46%) out of 37 patients who underwent CECT within day 3, the contrast enhancement was remarkable. Transient or permanent symptomatic vasospasm occurred in 13 (76.5%) out of these 17 patients and the remaining 4 patients who underwent the operation with successful removal of subarachnoid clot within day 3 did not develop symptomatic vasospasm. Eight (67%) out of 12 patients operated within day 3, in whom post-operative CT showed incomplete removal of subarachnoid clot, developed transient or permanent symptomatic vasospasm. In only one (5%) out of 20 patients without remarkable enhancement, transient symptomatic vasospasm occurred. The abnormal contrast enhancement in the region of the circle of Willis and its branches within day 3 was closely related to the subsequent occurrence of vasospasm. Contrast enhanced CT was performed in 41 patients after day 3. There was no patient with remarkable enhancement on CECT. There was no relationship between the findings on CECT after day 3 and the occurrence of vasospasm. CECT within day 3 allows prediction of that patient destined for vasospasm and early removal of subarachnoid clot within day 3 may minimize the future development of vasospasm.(J.P.N.)

  13. FDG PET/CT Is Superior to Enhanced CT in Detecting Recurrent Subcentimeter Lesions in the Abdominopelvic Cavity in Colorectal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hai Jeon; Kim, Yu Kyeong; Kim, Sang Eun [Seoul National Univ. Bundang Hospital, Seoul (Korea, Republic of); Lee, Jong Jin [Asan Medical Center, Univ. of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    This study aims to compare the performance of contrast enhanced computed tomography (CeCT) and 18 F fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in detecting small tumor implants and metastatic lymph nodes (LNs) in the abdominopelvic cavity in patients with colorectal cancer. We enrolled 16 patients who were clinically suspected of experiencing a recurrences (6 male, 10 female; mean age 61{+-}14 years). All subjects underwent CeCT and PET/CT, and the performance of these methods was compared with regard to detecting recurrences. The final diagnosis of a recurrence was made clinically. CeCT identified 38 lesions in 12 patients, all of which were detected by PET/CT. PET/CT found 27 additional lesions in 8 patients, comprising 9 seeding nodules (2 in the right upper quadrant of the abdomen and 7 in the pelvic cavity) and 18 LNs (2 celiac, 2 paraaortic, 2 hepatic hilar, 11 common iliac, 1 external iliac). Most additional lesions were located in the pelvic cavity (approximately 78% of seeding nodules that were detected solely by PET/CT was significantly higher compared with the CeCT and PET/CT confirmed nodules (5.5{+-}4.2 vs. 2.9{+-}2.5, p=0.03). The seeding nodules that were detected only by PET/CT were significantly smaller than the CeCT and PET/CT confirmed nodules (long axis:1.0{+-}0.3cm vs. 2.0{+-}1.1cm, p=0.001; short axis: 0.8{+-}0.3cm vs. 1.7{+-}0.9cm, p=0.001). Similarly, PET/CT only detected LNs were significantly smaller than CeCT and PET/CT identified LNs (0.7{+-}0.1cm vs. 2.3{+-}1.2cm, p<0.0001). PET/CT is superior to CeCT in detecting seeding nodules and metastatic LNs in patients with recurrent colorectal cancer. Specifically, PET/CT detects subcentimeter lesions in anatomically deformed pelvic cavities.

  14. Helical type vacuum container

    International Nuclear Information System (INIS)

    Owada, Kimio.

    1989-01-01

    Helical type vacuum containers in the prior art lack in considerations for thermal expansion stresses to helical coils, and there is a possibility of coil ruptures. The object of the present invention is to avoid the rupture of helical coils wound around the outer surface of a vacuum container against heat expansion if any. That is, bellows or heat expansion absorbing means are disposed to a cross section of a helical type vacuum container. With such a constitution, thermal expansion of helical coils per se due to temperature elevation of the coils during electric supply can be absorbed by expansion of the bellows or absorption of the heat expansion absorbing means. Further, this can be attained by arranging shear pins in the direction perpendicular to the bellows axis so that the bellows are not distorted when the helical coils are wound around the helical type vacuum container. (I.S.)

  15. FDG-PET, CT, MRI for diagnosis of local residual or recurrent nasopharyngeal carcinoma, which one is the best? A systematic review

    International Nuclear Information System (INIS)

    Liu Tao; Xu Wen; Yan Weili; Ye Ming; Bai Yongrui; Huang Gang

    2007-01-01

    Purpose: To perform a systematic review to compare FDG-PET, CT, and MRI imaging for diagnosis of local residual or recurrent nasopharyngeal carcinoma. Materials and methods: MEDLINE, EMBASE, the CBMdisc databases and some other databases were searched for relevant original articles published from January 1990 to June 2007. Inclusion criteria were as follows: Articles were reported in English or Chinese; FDG-PET, CT, or MRI was used to detect local residual or recurrent nasopharyngeal carcinoma; histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were the reference standard. Two reviewers independently extracted data. A software called 'Meta-DiSc' was used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the Q* index. Results: Twenty-one articles fulfilled all inclusion criteria. The pooled sensitivity estimates for PET (95%) were significantly higher than CT (76%) (P 0.05). Conclusion: FDG-PET was the best modality for diagnosis of local residual or recurrent nasopharyngeal carcinoma. The type of analysis for PET imaging and the section thickness for CT would affect the diagnostic results. Dual-section helical and multi-section helical CT were better than nonhelical and single-section helical CT

  16. Cost reduction in abdominal CT by weight-adjusted dose

    International Nuclear Information System (INIS)

    Arana, Estanislao; Marti-Bonmati, Luis; Tobarra, Eva; Sierra, Consuelo

    2009-01-01

    Aim: To analyze the influence of contrast dose adjusted by weight vs. fixed contrast dose in the attenuation and cost of abdominal computed tomography (CT). Materials and methods: A randomised, consecutive, parallel group study was conducted in 151 patients (74 men and 77 women, age range 22-67 years), studied with the same CT helical protocol. A dose at 1.75 ml/kg was administered in 101 patients while 50 patients had a fixed dose of 120 ml of same non-ionic contrast material (320 mg/ml). Mean enhancements were measured at right hepatic lobe, superior abdominal aorta and inferior cava vein. Statistical analysis was weight-stratified ( 81 kg). Results: Aortic attenuation was significantly superior (p 61 kg in dose-adjusted group, presented higher hepatic attenuation, being statistically significant in those >81 kg (p 80 kg, there was an over cost of Euro 10.7 per patient. Conclusions: An injection volume of 1.75 ml/kg offers an optimal diagnostic quality with a global savings of Euro 1.34 per patient.

  17. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  18. Effect of tumor volume on the enhancement pattern of parathyroid adenoma on parathyroid four-dimensional CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Kyoung [Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Dongguk University Ilsan Hospital, Department of Radiology, Goyang-si (Korea, Republic of); Yun, Tae Jin; Kim, Ji-hoon; Kang, Koung Mi; Choi, Seung Hong; Sohn, Chul-Ho [Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Lee, Kyu Eun; Kim, Su-jin [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of); Won, Jae-Kyung [Seoul National University Hospital, Department of Pathology, Seoul (Korea, Republic of)

    2016-05-15

    The purpose of this study is to assess the effect of tumor volume on the enhancement pattern of parathyroid adenoma (PTA) on four-dimensional computed tomography (4D-CT). We analyzed the enhancement patterns of PTA on four-phase 4D-CT in 44 patients. Dependency of the changes of Hounsfield unit values (ΔHU) on the tumor volumes and clinical characteristics was evaluated using linear regression analyses. In addition, an unpaired t test was used to compare ΔHU of PTAs between PTA volume ≥1 cm{sup 3} and <1 cm{sup 3}, thyroid gland, and lymph node. PTA volume based on CT was the strongest factor on the ΔHU{sub Pre} {sub to} {sub Arterial} and ΔHU{sub Arterial} {sub to} {sub Venous} and ΔHU{sub Arterial} {sub to} {sub Delayed} (R {sup 2} = 0.34, 0.25, and 0.32, respectively, P < 0.001 for both). PTA ≥1 cm {sup 3} had statistically significant greater enhancement between the unenhanced phase and the arterial phase than PTA <1 cm {sup 3} (mean values ± standard deviations (SDs) of ΔHU{sub Pre} {sub to} {sub Arterial}, 102.7 ± 33.7 and 57.5 ± 28.8, respectively, P < 0.001). PTA ≥1 cm {sup 3} showed an early washout pattern on the venous phase, whereas PTA <1 cm {sup 3} showed a progressive enhancement pattern on the venous phase (mean values ± SDs of ΔHU{sub Arterial} {sub to} {sub Venous}, -13.2 ± 31.6 and 14.4 ± 32.7, respectively; P = 0.009). The enhancement pattern of PTA on 4D-CT is variable with respect to PTA volume based on CT. Therefore, the enhancement pattern of PTA on 4D-CT requires careful interpretation concerning the tumor volume, especially in cases of PTA <1 cm {sup 3}. (orig.)

  19. Observation of enhanced radial transport of energetic ion due to energetic particle mode destabilized by helically-trapped energetic ion in the Large Helical Device

    Science.gov (United States)

    Ogawa, K.; Isobe, M.; Kawase, H.; Nishitani, T.; Seki, R.; Osakabe, M.; LHD Experiment Group

    2018-04-01

    A deuterium experiment was initiated to achieve higher-temperature and higher-density plasmas in March 2017 in the Large Helical Device (LHD). The central ion temperature notably increases compared with that in hydrogen experiments. However, an energetic particle mode called the helically-trapped energetic-ion-driven resistive interchange (EIC) mode is often excited by intensive perpendicular neutral beam injections on high ion-temperature discharges. The mode leads to significant decrease of the ion temperature or to limiting the sustainment of the high ion-temperature state. To understand the effect of EIC on the energetic ion confinement, the radial transport of energetic ions is studied by means of the neutron flux monitor and vertical neutron camera newly installed on the LHD. Decreases of the line-integrated neutron profile in core channels show that helically-trapped energetic ions are lost from the plasma.

  20. Differentiation of focal-type autoimmune pancreatitis from pancreatic carcinoma: assessment by multiphase contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Furuhashi, Naohiro; Suzuki, Kojiro; Sakurai, Yusuke; Naganawa, Shinji [Nagoya University Graduate School of Medicine, Department of Radiology, Nagoya (Japan); Ikeda, Mitsuru [Nagoya University Graduate School of Medicine, Department of Radiological Technology, Nagoya (Japan); Kawai, Yuichi [Japanese Red Cross Nagoya Daiichi Hospital, Department of Diagnostic Radiology, Nagoya (Japan)

    2015-05-01

    To evaluate the utility of multiphase contrast-enhanced computed tomography (CT) findings alone and in combination for differentiating focal-type autoimmune pancreatitis (f-AIP) from pancreatic carcinoma (PC). The study group comprised 22 f-AIP lesions and 61 PC lesions. Two radiologists independently evaluated CT findings. Frequencies of findings were compared between f-AIP and PC. Statistical, univariate and multivariate analyses were performed. Homogeneous enhancement during the portal phase (AIP, 59 % vs. PC, 3 %; P < 0.001), dotted enhancement during the pancreatic phase (50 % vs. 7 %; P < 0.001), duct-penetrating sign (46 % vs. 2 %; P < 0.001), enhanced duct sign (36 % vs. 2 %; P < 0.001) and capsule-like rim (46 % vs. 3 %; P < 0.001) were more frequently observed in AIP. Ring-like enhancement during the delayed phase (5 % vs. 46 %; P < 0.001) and peripancreatic strands with a length of at least 10 mm (5 % vs. 39 %; P = 0.001) were more frequently observed in PC. AIP was identified with 82 % sensitivity and 98 % specificity using four of these seven findings. Multivariate analysis revealed significant differences in dotted enhancement (P = 0.004), duct-penetrating sign (P < 0.001) and capsule-like rim (P = 0.007). The combination of CT findings may allow improvements in differentiating f-AIP from PC. (orig.)

  1. Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients

    International Nuclear Information System (INIS)

    D'Agostino, A.G.; Remy-Jardin, M.; Khalil, C.; Remy, J.; Delannoy-Deken, V.; Duhamel, A.; Flohr, T.

    2006-01-01

    The purpose of this study was to evaluate image quality of low-dose electrocardiogram (ECG)-gated multislice helical computed tomography (CT) angiograms of the chest. One hundred and five consecutive patients with a regular sinus rhythm (72 men; 33 women) underwent ECG-gated CT angiographic examination of the chest without administration of beta blockers using the following parameters: (a) collimation 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices, rotation time 0.33 s, pitch 0.3; (b) 120 kV, 200 mAs; (c) use of two dose modulation systems, including adjustment of the mAs setting to the patient's size and anatomical shape and an ECG-controlled tube current. Subjective and objective image quality was evaluated by two radiologists in consensus on 3-mm-thick scans reconstructed at 55% of the response rate (RR) interval. The population and protocol characteristics included: (a) a mean [±standard deviation (SD)] body mass index (BMI) of 24.47 (±4.64); (b) a mean (±SD) heart rate of 72.04 (±15.76) bpm; (c) a mean (±SD) scanning time of 18.3 (±2.73) s; (d) a mean (±SD) dose-length product (DLP) value of 260.57 (±83.67) mGy/cm; (e) an estimated average effective dose of 4.95 (±1.59) mSv. Subjective noise was depicted in a total of nine examinations (8.5%), always rated as mild. Objective noise was assessed by measuring the standard deviation of pixel values in a homogeneous region of interest within the trachea and descending aorta; SD was 15.91 HU in the trachea and 22.16 HU in the descending aorta, with no significant difference in the mean value of the standard deviations between the four categories of BMI except for obese patients, who had a higher mean SD within the aorta. Interpolation artefacts were depicted in 22 patients, with a mean heart rate significantly lower than that of patients without interpolation artifacts, rated as mild in 11 patients and severe in 11 patients. The severity of interpolation artefacts

  2. Nonlinear behavior of multiple-helicity resistive interchange modes near marginally stable states

    International Nuclear Information System (INIS)

    Sugama, Hideo; Nakajima, Noriyoshi; Wakatani, Masahiro.

    1991-05-01

    Nonlinear behavior of resistive interchange modes near marginally stable states is theoretically studied under the multiple-helicity condition. Reduced fluid equations in the sheared slab configuration are used in order to treat a local transport problem. With the use of the invariance property of local reduced fluid model equations under a transformation between the modes with different rational surfaces, weakly nonlinear theories for single-helicity modes by Hamaguchi and Nakajima are extended to the multiple-helicity case and applied to the resistive interchange modes. We derive the nonlinear amplitude equations of the multiple-helicity modes, from which the convective transport in the saturated state is obtained. It is shown how the convective transport is enhanced by nonlinear interaction between modes with different rational surfaces compared with the single-helicity case. We confirm that theoretical results are in good agreement with direct numerical simulations. (author)

  3. Estimation of organ-absorbed radiation doses during 64-detector CT coronary angiography using different acquisition techniques and heart rates: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, Kosuke; Koshida, Kichiro; Kawashima, Hiroko (Dept. of Quantum Medical Technology, Faculty of Health Sciences, Kanazawa Univ., Kanazawa (Japan)), email: matsuk@mhs.mp.kanazawa-u.ac.jp; Noto, Kimiya; Takata, Tadanori; Yamamoto, Tomoyuki (Dept. of Radiological Technology, Kanazawa Univ. Hospital, Kanazawa (Japan)); Shimono, Tetsunori (Dept. of Radiology, Hoshigaoka Koseinenkin Hospital, Hirakata (Japan)); Matsui, Osamu (Dept. of Radiology, Faculty of Medicine, Kanazawa Univ., Kanazawa (Japan))

    2011-07-15

    Background: Though appropriate image acquisition parameters allow an effective dose below 1 mSv for CT coronary angiography (CTCA) performed with the latest dual-source CT scanners, a single-source 64-detector CT procedure results in a significant radiation dose due to its technical limitations. Therefore, estimating the radiation doses absorbed by an organ during 64-detector CTCA is important. Purpose: To estimate the radiation doses absorbed by organs located in the chest region during 64-detector CTCA using different acquisition techniques and heart rates. Material and Methods: Absorbed doses for breast, heart, lung, red bone marrow, thymus, and skin were evaluated using an anthropomorphic phantom and radiophotoluminescence glass dosimeters (RPLDs). Electrocardiogram (ECG)-gated helical and ECG-triggered non-helical acquisitions were performed by applying a simulated heart rate of 60 beats per minute (bpm) and ECG-gated helical acquisitions using ECG modulation (ECGM) of the tube current were performed by applying simulated heart rates of 40, 60, and 90 bpm after placing RPLDs on the anatomic location of each organ. The absorbed dose for each organ was calculated by multiplying the calibrated mean dose values of RPLDs with the mass energy coefficient ratio. Results: For all acquisitions, the highest absorbed dose was observed for the heart. When the helical and non-helical acquisitions were performed by applying a simulated heart rate of 60 bpm, the absorbed doses for heart were 215.5, 202.2, and 66.8 mGy for helical, helical with ECGM, and non-helical acquisitions, respectively. When the helical acquisitions using ECGM were performed by applying simulated heart rates of 40, 60, and 90 bpm, the absorbed doses for heart were 178.6, 139.1, and 159.3 mGy, respectively. Conclusion: ECG-triggered non-helical acquisition is recommended to reduce the radiation dose. Also, controlling the patients' heart rate appropriately during ECG-gated helical acquisition with

  4. 18F-FDG-PET/CT parameters as imaging biomarkers in oral cavity squamous cell carcinoma, is visual analysis of PET and contrast enhanced CT better than the numbers?

    Energy Technology Data Exchange (ETDEWEB)

    Kendi, A.Tuba, E-mail: ayse.kendi@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Corey, Amanda [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Magliocca, Kelly R. [Department of Pathology, Emory University, Atlanta, GA (United States); Nickleach, Dana C. [Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute of Emory University, Atlanta, GA (United States); Galt, James [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Switchenko, Jeffrey M. [Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute of Emory University, Atlanta, GA (United States); El-Deiry, Mark W.; Wadsworth, J. Trad [Otolaryngology Head and Neck Surgery, Emory University, Atlanta, GA (United States); Hudgins, Patricia A. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Saba, Nabil F. [Hematology Oncology, Winship Cancer Institute of Emory University, Atlanta, GA (United States); Schuster, David M. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States)

    2015-06-15

    Highlights: • Highlights of our study were the significant association of higher T stage of oral cavity squamous cell carcinoma with PET/CT parameters. • This could be an important finding in cases where it is difficult to decide on T stage by CT only. • We found a significant association between ring/heterogeneous enhancement pattern of (either primary or nodal or both) oral cavity squamous cell carcinoma at contrast enhanced CT and poor prognosis. • This could be related to hypoxia, which is a known reason for therapy resistance. Hence therapies can be tailored in the feature depending on enhancement pattern on contrast enhanced CT. - Abstract: Purpose: This study was designed to seek associations between positron emission tomography/computed tomography (PET/CT) parameters, contrast enhanced neck computed tomography (CECT) and pathological findings, and to determine the potential prognostic value of PET/CT and CECT parameters in oral cavity squamous cell carcinoma (OCSCC). Materials and method: 36 OCSCC patients underwent staging PET/CT and 30/36 of patients had CECT. PET/CT parameters were measured for the primary tumor and the hottest involved node, including maximum, mean, and peak standardized uptake values (SUV max, SUV mean, and SUV peak), metabolic tumor volume (MTV), total lesion glycolysis (TLG), standardized added metabolic activity (SAM), and normalized standardized added metabolic activity (N SAM). Qualitative assessment of PET/CT and CECT were also performed. Pathological outcomes included: perineural invasion, lymphovascular invasion, nodal extracapsular spread, grade, pathologic T and N stages. Multivariable logistic regression models were fit for each parameter and outcome adjusting for potentially confounding variables. Multivariable Cox proportional hazards models were used for progression free survival (PFS), locoregional recurrence free survival (LRFS), overall survival (OS) and distant metastasis free survival (DMFS). Results: In

  5. 18F-FDG-PET/CT parameters as imaging biomarkers in oral cavity squamous cell carcinoma, is visual analysis of PET and contrast enhanced CT better than the numbers?

    International Nuclear Information System (INIS)

    Kendi, A.Tuba; Corey, Amanda; Magliocca, Kelly R.; Nickleach, Dana C.; Galt, James; Switchenko, Jeffrey M.; El-Deiry, Mark W.; Wadsworth, J. Trad; Hudgins, Patricia A.; Saba, Nabil F.; Schuster, David M.

    2015-01-01

    Highlights: • Highlights of our study were the significant association of higher T stage of oral cavity squamous cell carcinoma with PET/CT parameters. • This could be an important finding in cases where it is difficult to decide on T stage by CT only. • We found a significant association between ring/heterogeneous enhancement pattern of (either primary or nodal or both) oral cavity squamous cell carcinoma at contrast enhanced CT and poor prognosis. • This could be related to hypoxia, which is a known reason for therapy resistance. Hence therapies can be tailored in the feature depending on enhancement pattern on contrast enhanced CT. - Abstract: Purpose: This study was designed to seek associations between positron emission tomography/computed tomography (PET/CT) parameters, contrast enhanced neck computed tomography (CECT) and pathological findings, and to determine the potential prognostic value of PET/CT and CECT parameters in oral cavity squamous cell carcinoma (OCSCC). Materials and method: 36 OCSCC patients underwent staging PET/CT and 30/36 of patients had CECT. PET/CT parameters were measured for the primary tumor and the hottest involved node, including maximum, mean, and peak standardized uptake values (SUV max, SUV mean, and SUV peak), metabolic tumor volume (MTV), total lesion glycolysis (TLG), standardized added metabolic activity (SAM), and normalized standardized added metabolic activity (N SAM). Qualitative assessment of PET/CT and CECT were also performed. Pathological outcomes included: perineural invasion, lymphovascular invasion, nodal extracapsular spread, grade, pathologic T and N stages. Multivariable logistic regression models were fit for each parameter and outcome adjusting for potentially confounding variables. Multivariable Cox proportional hazards models were used for progression free survival (PFS), locoregional recurrence free survival (LRFS), overall survival (OS) and distant metastasis free survival (DMFS). Results: In

  6. Evaluation of dynamic enhanced CT scanning in the differentiation of adrenal lipid-poor adenomas with metastases

    International Nuclear Information System (INIS)

    Fang Xiangming; Hu Chunhong; Hu Xiaoyun; Chen Hongwei; Wu Liyuan; Zou Xinnong; Qian Pingyan

    2006-01-01

    Objective: To evaluate dynamic enhanced CT in differentiating adrenal metastases from adrenal lipid-poor adenomas(ALPA). Methods: Both plain and dynamic enhanced CT scanning was performed in 9 metastases with 13 masses and 28 lipid-poor adenoma with 30 masses. The types of time-density curve according to peak time(PT) and relative washout percentage(Washr) besides shape, size, margin, internal structure, surrounding status and enhanced pattern of each lesion were measuerd and compared between the two groups of metastases and ALPA. Results: There is difference between metastases and ALPA in the aspects of shape, density, neighboring structure and the type of enhancement. The type of TDC of matastases was characterized by fast-washin and fast-washout, which was quite differed from the type of TDC of ALPA characterized by fast-washin and slow-washout. According to this, the sensitiveity and specificity for differentiating metastases from ALPA were 96.7%, 92.3%. Conclusion: The types of TDC of dynamic enhanced CT is of great value in differentiating metastases from ALPA. (authors)

  7. Respiratory-Gated Helical Computed Tomography of Lung: Reproducibility of Small Volumes in an Ex Vivo Model

    International Nuclear Information System (INIS)

    Biederer, Juergen; Dinkel, Julien; Bolte, Hendrik; Welzel, Thomas; Hoffmann, Beata M.Sc.; Thierfelder, Carsten; Mende, Ulrich; Debus, Juergen; Heller, Martin; Kauczor, Hans-Ulrich

    2007-01-01

    Purpose: Motion-adapted radiotherapy with gated irradiation or tracking of tumor positions requires dedicated imaging techniques such as four-dimensional (4D) helical computed tomography (CT) for patient selection and treatment planning. The objective was to evaluate the reproducibility of spatial information for small objects on respiratory-gated 4D helical CT using computer-assisted volumetry of lung nodules in a ventilated ex vivo system. Methods and Materials: Five porcine lungs were inflated inside a chest phantom and prepared with 55 artificial nodules (mean diameter, 8.4 mm ± 1.8). The lungs were respirated by a flexible diaphragm and scanned with 40-row detector CT (collimation, 24 x 1.2 mm; pitch, 0.1; rotation time, 1 s; slice thickness, 1.5 mm; increment, 0.8 mm). The 4D-CT scans acquired during respiration (eight per minute) and reconstructed at 0-100% inspiration and equivalent static scans were scored for motion-related artifacts (0 or absent to 3 or relevant). The reproducibility of nodule volumetry (three readers) was assessed using the variation coefficient (VC). Results: The mean volumes from the static and dynamic inspiratory scans were equal (364.9 and 360.8 mm 3 , respectively, p = 0.24). The static and dynamic end-expiratory volumes were slightly greater (371.9 and 369.7 mm 3 , respectively, p = 0.019). The VC for volumetry (static) was 3.1%, with no significant difference between 20 apical and 20 caudal nodules (2.6% and 3.5%, p = 0.25). In dynamic scans, the VC was greater (3.9%, p = 0.004; apical and caudal, 2.6% and 4.9%; p = 0.004), with a significant difference between static and dynamic in the 20 caudal nodules (3.5% and 4.9%, p = 0.015). This was consistent with greater motion-related artifacts and image noise at the diaphragm (p <0.05). The VC for interobserver variability was 0.6%. Conclusion: Residual motion-related artifacts had only minimal influence on volumetry of small solid lesions. This indicates a high reproducibility of

  8. Meso-Helical Ag(I) Coordination Polymer Based on a Pyridylimidazole Ligand

    International Nuclear Information System (INIS)

    Kang, Youngjin; Kim, Jinho; Lee, Eunji; Park, Ki-Min; Moon, Suk-Hee

    2016-01-01

    In the fields of material science and metallosupramolecular chemistry, coordination polymers with various helical types have been extensively explored because of their charming structures, and their potential applications in material chemistry. Among them, meso-helical coordination polymers consisting of achiral 1D strands, which are generally constructed by a crystallographic inversion symmetry, are relatively rare. The coordination polymer 1 exhibits a rare one-dimensional meso-helical chain topology constructed by its internal inversion symmetry. The skeleton of this meso-helical chain is preserved up to 300°C. The complexation of silver(I) ion to the free pyim ligand give rise to the enhanced photoluminescence intensity and slightly blue-shifted emission maximum, originated from intraligand (IL) π[BOND]π* transition and rigidochromic effect. Further exploration of complexation of this ligand with other transition metal ions is currently in progress

  9. The use of contrast-enhanced post Mortem CT in the detection of cardiovascular deaths.

    Directory of Open Access Journals (Sweden)

    Jonas Christoph Apitzsch

    Full Text Available OBJECTIVES: To evaluate the diagnostic value of contrast enhanced post mortem computed tomography (PMCT in comparison to non-enhanced post mortem CT in the detection of cardiovascular causes of death (COD. BACKGROUND: As autopsy rates decline, new methods to determine CODs are necessary. So contrast enhanced PMCT shall be evaluated in comparison to established non-enhanced PMCT in order to further improve the method. METHODS: In a prospective study, 20 corpses were examined using a 64-row multisclice CT (MSCT before and after intraarterial perfusion with a newly developed, barium-bearing contrast agent and ventilation of the lungs. The cause of death was determined in enhanced and unenhanced scans and a level of confidence (LOC was given by three experienced radiologists on a scale between 0 and 4. Results were compared to autopsy results as gold standard. Autopsy was performed blinded to PMCT-findings. RESULTS: The method allowed visualization of different types of cause of death. There was a significant improvement in LOC in enhanced scans compared to unenhanced scans as well as an improvement in the detection of COD. The cause of death could be determined in 19 out of 20 patients. CONCLUSIONS: PMCT is feasible and appears to be robust for diagnosing cardiovascular causes of death. When compared with unenhanced post-mortem CT intraarterial perfusion and pulmonary ventilation significantly improve visualization and diagnostic accuracy. These promising results warrant further studies.

  10. Investigation into the heat transfer performance of helically ribbed surfaces

    International Nuclear Information System (INIS)

    Firth, R.J.

    1981-12-01

    The first part of an investigation into flow and heat transfer in annular channels and seven pin clusters is described. One of the main aims of the project is to improve cluster heat transfer prediction codes for helically ribbed surfaces. A study is made of the heat transfer and flow characteristics of a helically ribbed pin in an annular channel. It is shown that the swirling flow, which is induced by the helical ribs, gives rise to substantially enhanced diffusivity levels. This phenomenon had not been taken into account by previous analysis techniques. The methods for analysing heat transfer and pressure drop data from annular channels which were originally developed for non-swirling flow are generalised to accommodate swirling flow. The new methods are shown to be consistent with empirical data. Roughness parameter data is presented for helically ribbed surfaces with an axial rib pitch into height ratio of about 7. (author)

  11. Investigation of mixing enhancement in porous media under helical flow conditions: 3-D bench-scale experiments

    DEFF Research Database (Denmark)

    Chiogna, Gabriele; Ye, Yu; Cirpka, Olaf A.

    2017-01-01

    us to quantify spreading and dilution of the solute plumes at the outlet cross section. Moreover, we collected direct evidence of plume spiraling and visual proof of helical flow by freezing and slicing the porous medium at different cross sections and observing the dye-tracer distribution. Model...... performed steady-state conservative tracer experiments in a fully three-dimensional flow-through chamber to investigate the effects of helical flow on plume spiraling and deformation, as well as on its dilution [4]. Helical flow was created by packing the porous medium in angled stripes of materials...

  12. Appendicitis and alternate diagnoses in children: findings on unenhanced limited helical CT

    International Nuclear Information System (INIS)

    Lowe, L.H.; Perez, R. Jr.; Scheker, L.E.; Stein, S.M.; Heller, R.M.; Hernanz-Schulman, M.

    2001-01-01

    The objective of this manuscript is to review and illustrate the findings of appendicitis, and of alternate diagnoses that may clinically or radiographically simulate appendicitis, on unenhanced limited CT in children. Potential pitfalls in unenhanced limited CT interpretation of pediatric patients will also be discussed. (orig.)

  13. Evaluation of radiation exposure with singleslice- and a multislice-spiral CT system (a phantom study)

    International Nuclear Information System (INIS)

    Giacomuzzi, S.M.; Rieger, M.; Lottersberger, C.; Peer, S.; Peer, R.; Buchberger, W.; Bale, R.; Mallouhi, A.; Jaschke, W.; Torbica, P.; Perkmann, R.

    2001-01-01

    The purpose of study was to compare patient dose applying singleslice- and multislice-spiral CT. Methods: The examinations were performed with a singleslice-spiral CT (Highspeed Advantage; GE Medical Systems; Milwaukee, USA) and with a multislice CT systems (LightSpeed QX/i GE Medical Systems; Milwaukee, USA). For the determination of the radiation exposure (absorbed dose) a selection of most executed protocols (thorax-helical, abdomen-helical, petrous bone-axial, head-axial) were simulated using an Alderson Rando Phantom. The dose was determined by means of lithiumfluorid-thermoluminescence dosimeters (TLD-GR 200). Results: For thorax and abdomen protocols higher energy dose values could be found using a multislice CT. On the average the energy dose values were increased by 2.6 on an average in relation to single slice spiral CT. The energy dose values of the multisclice CT using head protocols could be reduced by 30% in relation to single slice spiral CT due to suitable parameter selections. The energy dose applying a petrous bone protocol resulted in an average increase by a factor 1.5 using a multislice CT. Conclusion: Using the new multislice CT technique protocol strategies must be optimized regarding the patient doses. Users can operate critically in the sense of the radiation protection only if they are aware of the occurring dose amounts to the patient. (orig.) [de

  14. Cranial CT revisited: do we really need contrast enhancement?

    International Nuclear Information System (INIS)

    Demaerel, P.; Buelens, C.; Wilms, G.; Baert, A.L.

    1998-01-01

    The aim of this study was to define guidelines for intravenous contrast administration in cranial CT, as currently there are no recent guidelines based on a large series of patients. In 1900 consecutive patients (1480 adults and 420 children) pre- and post-contrast scan was analysed in order to assess the contribution of contrast enhancement to the diagnosis. The findings were grouped according to whether abnormalities were seen on the pre- and/or post-contrast scan, or whether no abnormalities were seen at all. Sensitivity, specificity, positive predictive value, negative predictive value and accurracy of a pre-contrast scan were used to determine validity. Intravenous contrast enhancement only contributes to the diagnosis if a suspicious abnormality is seen on the unenhanced scan or in the appropriate clinical setting (33.6 %). In the remaining patients (65.6 %) there is no diagnostic contribution, except for a small number of abnormalities (0.8 %). These are often anatomical variants and have no therapeutic impact. The number of contrast-enhanced cranial CT examinations can significantly be reduced by using four general guidelines for contrast administration resulting in considerable cost savings without affecting the quality of service to the patient. These guidelines are defined by the clinical findings/presentation or by the findings on the unenhanced scan. The number of contrast-related complications will be reduced, which may have medicolegal implications. These guidelines can be applied in any radiology department. (orig.) (orig.)

  15. The diagnostic value of contrast-enhanced CT in Acute bilateral renal cortical necrosis: a case report

    International Nuclear Information System (INIS)

    Choi, Pil Youb; Lee, Su Han; Lee, Woo Dong

    1996-01-01

    Acute renal cortical necrosis in which there is destruction of the renal cortex and sparing of the renal medulla, is a relatively rare cause of acute renal failure. A definitive diagnosis of acute renal cortical necrosis is based on renal biopsy, but on CT(computed tomography) the rather specific contrast-enhanced appearance of acute renal cortical necrosis has been described. As renal biopsy is not available, contrast-enhanced CT is a useful, noninvasive investigate modality for the early diagnosis of acute renal cortical necrosis. We report the characteristic CT findings of acute renal cortical necrosis in a patient with acute renal failure following an operation for abdominal trauma

  16. Predicting tumor hypoxia in non-small cell lung cancer by combining CT, FDG PET and dynamic contrast-enhanced CT.

    Science.gov (United States)

    Even, Aniek J G; Reymen, Bart; La Fontaine, Matthew D; Das, Marco; Jochems, Arthur; Mottaghy, Felix M; Belderbos, José S A; De Ruysscher, Dirk; Lambin, Philippe; van Elmpt, Wouter

    2017-11-01

    Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUV mean ) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm 3 ) by the best performing model. We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The

  17. Enhancing pattern of gastric carcinoma at dynamic incremental CT: correlation with gross and histologic findings

    International Nuclear Information System (INIS)

    Shin, Hong Seop; Lee, Dong Ho; Kim, Yoon Hwa; Ko, Young Tae; Lim, Joo Won; Yoon, Yup

    1996-01-01

    To evaluate the enhancing pattern of gastric carcinomas at dynamic incremental CT and to correlate it with pathologic findings. We retrospectively evaluated the enhancement pattern of stomach cancer on dynamic incremental CT of the 78 patients. All the lesions had been pathologically proved after surgery. The enhancement pattern was categorized as good or poor in the early phase;homogeneous, heterogeneous or ring enhancement;the presence or absence of delayed enhancement. There were 16 cases of early gastric cancer (EGC), and 62 cases of advanced gastric cancer(AGC). The Borrmann type of AGC were 1(n=1), 2(n=20), 3=(n=32), 4(n=8) and 5(n=1). The histologic patterns of AGC were tubular(n=49), signet ring cell(n=10), and mucinous(n=3). The enhancing patterns were compared with gross and histologic findings and delayed enhancement was correlated with pathologic evidence of desmoplasia. Good enhancement of tumor was seen in 24/41cases (58.5%) with AGC Borrmann type 3-5, in 6/21(28.6%) with AGC Borrmann type 1-2, and in 3/16(18.8%) with EGC (P<.05). By histologic pattern, good enhancement of tumor was seen in 8/10(80%) with signet ring cell type, in 21/49(42.9%) with tubular type, and in 1/3(33.3%) with mucinous type(P<.05). EGC was homogeneously enhanced in 14/16cases (87.5%), but AGC was heterogeneously enhanced in 33/62(53.2%), respectively(P<.01). There was no significant correlation between delayed enhancement and the presence of desmoplasia. AGC Borrmann type 3-5 and signet ring cell type have a tendency to show good enhancement and EGC is more homogeneously enhanced at dynamic incremental CT

  18. Bone changes in the condylar head and mandibular fossa in patients with temporomandibular disorders. Helical CT observation

    International Nuclear Information System (INIS)

    Shimahara, Satoru; Ariyoshi, Yasunori; Kimura, Yoshihiro; Shimahara, Masashi

    2011-01-01

    In the present study, we investigated whether bone changes are present in sites impossible to observe by panoramic X-ray and Schuller's X-ray examination, namely the medial of the condylar head and mandibular fossa, in patients with type IV temporomandibular joint disorders. We observed the articular fossa using computed tomography, which is able to obtain detailed 3-dimensional information, in patients with type IV temporomandibular disorders. We examined 120 joints of 60 patiens who visited the Department of Oral Surgery, Osaka Medical College Hospital. Each condylar head was clearly visualized in panoramic X-ray and Schuller's X-ray examination findings, and shown to have possible changes unilaterally. Each joint was diagnosed as type IV, according to the diagnostic guidelines set by Japanese Society for Temporomandibular Joint, and further examined using helical CT. Changes in condylar head; We concluded that bone changes were present with considerable probability in the medial of condylar head in a manner similar to those found in the lateral and center of joints with type IV temporomandibular disorders. Changes in mandibular fossa; The bone changes occurred in various locations of the mandibular fossa, while they appeared significantly more frequently in the condylar head. We think that our finding will contribute to development of treatment strategies for temporomandibular disorders, as they clarify bone changes in sites previously unreported. (author)

  19. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  20. Estimated risk of radiation-induced cancer from paediatric chest CT: two-year cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Tilo [Cantonal Hospital Baden, Department of Radiology, Baden (Switzerland); University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Colas, Lucie; Santangelo, Teresa; Faivre, Jean Baptiste; Remy, Jacques; Remy-Jardin, Martine [University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Roser, Hans W.; Bremerich, Jens [University of Basel Hospital, Clinic of Radiology and Nuclear Medicine, Medical Physics, Basel (Switzerland)

    2015-03-01

    The increasing absolute number of paediatric CT scans raises concern about the safety and efficacy and the effects of consecutive diagnostic ionising radiation. To demonstrate a method to evaluate the lifetime attributable risk of cancer incidence/mortality due to a single low-dose helical chest CT in a two-year patient cohort. A two-year cohort of 522 paediatric helical chest CT scans acquired using a dedicated low-dose protocol were analysed retrospectively. Patient-specific estimations of radiation doses were modelled using three different mathematical phantoms. Per-organ attributable cancer risk was then estimated using epidemiological models. Additional comparison was provided for naturally occurring risks. Total lifetime attributable risk of cancer incidence remains low for all age and sex categories, being highest in female neonates (0.34%). Summation of all cancer sites analysed raised the relative lifetime attributable risk of organ cancer incidence up to 3.6% in female neonates and 2.1% in male neonates. Using dedicated scan protocols, total lifetime attributable risk of cancer incidence and mortality for chest CT is estimated low for paediatric chest CT, being highest for female neonates. (orig.)

  1. Biot-Savart helicity versus physical helicity: A topological description of ideal flows

    Science.gov (United States)

    Sahihi, Taliya; Eshraghi, Homayoon

    2014-08-01

    For an isentropic (thus compressible) flow, fluid trajectories are considered as orbits of a family of one parameter, smooth, orientation-preserving, and nonsingular diffeomorphisms on a compact and smooth-boundary domain in the Euclidian 3-space which necessarily preserve a finite measure, later interpreted as the fluid mass. Under such diffeomorphisms the Biot-Savart helicity of the pushforward of a divergence-free and tangent to the boundary vector field is proved to be conserved and since these circumstances present an isentropic flow, the conservation of the "Biot-Savart helicity" is established for such flows. On the other hand, the well known helicity conservation in ideal flows which here we call it "physical helicity" is found to be an independent constant with respect to the Biot-Savart helicity. The difference between these two helicities reflects some topological features of the domain as well as the velocity and vorticity fields which is discussed and is shown for simply connected domains the two helicities coincide. The energy variation of the vorticity field is shown to be formally the same as for the incompressible flow obtained before. For fluid domains consisting of several disjoint solid tori, at each time, the harmonic knot subspace of smooth vector fields on the fluid domain is found to have two independent base sets with a special type of orthogonality between these two bases by which a topological description of the vortex and velocity fields depending on the helicity difference is achieved since this difference is shown to depend only on the harmonic knot parts of velocity, vorticity, and its Biot-Savart vector field. For an ideal magnetohydrodynamics (MHD) flow three independent constant helicities are reviewed while the helicity of magnetic potential is generalized for non-simply connected domains by inserting a special harmonic knot field in the dynamics of the magnetic potential. It is proved that the harmonic knot part of the vorticity

  2. A morphological study of the mandibular molar region using reconstructed helical computed tomographic images

    International Nuclear Information System (INIS)

    Tsuno, Hiroaki; Noguchi, Makoto; Noguchi, Akira; Yoshida, Keiko; Tachinami, Yasuharu

    2010-01-01

    This study investigated the morphological variance in the mandibular molar region using reconstructed helical computed tomographic (CT) images. In addition, we discuss the necessity of CT scanning as part of the preoperative assessment process for dental implantation, by comparing the results with the findings of panoramic radiography. Sixty patients examined using CT as part of the preoperative assessment for dental implantation were analyzed. Reconstructed CT images were used to evaluate the bone quality and cross-sectional bone morphology of the mandibular molar region. The mandibular cortical index (MCI) and X-ray density ratio of this region were assessed using panoramic radiography in order to analyze the correlation between the findings of the CT images and panoramic radiography. CT images showed that there was a decrease in bone quality in cases with high MCI. Cross-sectional CT images revealed that the undercuts on the lingual side in the highly radiolucent areas in the basal portion were more frequent than those in the alveolar portion. This study showed that three-dimensional reconstructed CT images can help to detect variances in mandibular morphology that might be missed by panoramic radiography. In conclusion, it is suggested that CT should be included as an important examination tool before dental implantation. (author)

  3. Polydopamine-coated gold nanostars for CT imaging and enhanced photothermal therapy of tumors

    Science.gov (United States)

    Li, Du; Shi, Xiangyang; Jin, Dayong

    2016-12-01

    The advancement of biocompatible nanoplatforms with dual functionalities of diagnosis and therapeutics is strongly demanded in biomedicine in recent years. In this work, we report the synthesis and characterization of polydopamine (pD)-coated gold nanostars (Au NSs) for computed tomography (CT) imaging and enhanced photothermal therapy (PTT) of tumors. Au NSs were firstly formed via a seed-mediated growth method and then stabilized with thiolated polyethyleneimine (PEI-SH), followed by deposition of pD on their surface. The formed pD-coated Au NSs (Au-PEI@pD NSs) were well characterized. We show that the Au-PEI@pD NSs are able to convert the absorbed near-infrared laser light into heat, and have strong X-ray attenuation property. Due to the co-existence of Au NSs and the pD, the light to heat conversion efficiency of the NSs can be significantly enhanced. These very interesting properties allow their uses as a powerful theranostic nanoplatform for efficient CT imaging and enhanced phtotothermal therapy of cancer cells in vitro and the xenografted tumor model in vivo. With the easy functionalization nature enabled by the coated pD shell, the developed pD-coated Au NSs may be developed as a versatile nanoplatform for targeted CT imaging and PTT of different types of cancer.

  4. The added value of 68Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin.

    Science.gov (United States)

    Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C

    2017-04-01

    To quantify the additional value of 68 Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced 68 Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and 68 Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up 68 Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • 68 Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • 68 Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.

  5. Isoattenuating insulinomas at biphasic contrast-enhanced CT: frequency, clinicopathologic features and perfusion characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Sun, Hao; Wang, Xuan; He, Yong-lan; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2016-10-15

    We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 2014, 170 patients (66 male, 104 female) with endogenous hyperinsulinemic hypoglycemia underwent biphasic contrast-enhanced CT before surgery, and 129 of those patients also received preoperative whole-pancreas CT perfusion. A total of 181 tumours were proved histopathologically after surgery. Enhancement pattern and regional pancreatic perfusion characteristics were analyzed. Clinical features, tumour size and pathological grading were investigated. The frequency of isoattenuating tumours was 24.9 %. Tumour size and WHO grading was not significantly different between isoattenuating and hyperattenuating tumours. Tumour-free regions had identical blood flow (BF) regardless of their location (p = 0.35). Isoattenuating tumour-harbouring regions had lower BF compared with hyperattenuating tumour-harbouring regions; both showed higher BF compared with tumour-free neighbourhood regions (all p < 0.01). For patients with isoattenuating tumours, the overall hospital stay was longer (p < 0.01). A substantial subset of insulinomas were isoattenuating on biphasic CT. CT perfusion showed higher BF in tumour-harbouring regions compared to tumour-free regions, providing a clue for tumour regionalization. (orig.)

  6. Dual-energy CT in the evaluation of solitary pulmonary nodules by virtual non-enhanced images: initial experience

    International Nuclear Information System (INIS)

    Guo Xing; Ding Wei; Qin Huijuan

    2011-01-01

    Objective: To determine the accuracy and radiation dose of dual-energy computed tomography (CT) in evaluating solitary pulmonary nodules (SPNs) by virtual non-enhanced images. Methods: Sixty-one patients with SPNs including 39 malignant and 18 benign nodules proved by pathology underwent DECT scans. The CT values of SPNs on enhanced weighted average and virtual non-enhanced images were compared by using Liver VNC processing unit in terms of their diagnostic accuracy for distinguishing malignant and benign nodules with a 20 HU threshold. Diagnostic accuracy was compared. In 28 patients of all patients, image noise and quality score of the non-enhanced and virtual non-enhanced images were compared, and radiation doses of each patient were recorded. The paired t test was used to analyze the noise difference between the plain scan and virtual non-enhanced scan. The Mann-Whitney U test. was used to analyze statistically significant differences of the image quality score and radiation dose between the non-enhanced scan and virtual non-enhanced scan. Results: The sensitivity, specificity and accuracy for distinguishing benign and malignant nodules by using the virtual non-enhanced image of were 89.7% (35/39), 72.2% (13/18), 84.2% (48/57) respectively. The noise of common CT and virtual non- enhanced images were (8.49±1.94) HU and (10.14±2.18) HU, and there were statistically difference (t=9.45, P 0.05). The radiation doses of common CT and DECT were (3.72±0.48) mSv and (3.78±0.45) mSv, and there were no statistical difference (U= 350.50, P>0.05). Conclusion: DECT by using virtual non-enhanced images is useful tool to distinguish the benign and malignant SPN without additional radiation dose. (authors)

  7. CTA-enhanced perfusion CT: an original method to perform ultra-low-dose CTA-enhanced perfusion CT

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Elizabeth; Wintermark, Max [University of Virginia, Department of Radiology, Neuroradiology Division, Charlottesville, VA (United States)

    2014-11-15

    Utilizing CT angiography enhances image quality in PCT, thereby permitting acquisition at ultra-low dose. Dynamic CT acquisitions were obtained at 80 kVp with decreasing tube current-time product [milliamperes x seconds (mAs)] in patients suspected of ischemic stroke, with concurrent CTA of the cervical and intracranial arteries. By utilizing fast Fourier transformation, high spatial frequencies of CTA were combined with low spatial frequencies of PCT to create a virtual PCT dataset. The real and virtual PCT datasets with decreasing mAs were compared by assessing contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and noise and PCT values and by visual inspection of PCT parametric maps. Virtual PCT attained CNR and SNR three- to sevenfold superior to real PCT and noise reduction by a factor of 4-6 (p < 0.05). At 20 mAs, virtual PCT achieved diagnostic parametric maps, while the quality of real PCT maps was inadequate. At 10 mAs, both real and virtual PCT maps were nondiagnostic. Virtual PCT (but not real PCT) maps regained diagnostic quality at 10 mAs by applying 40 % adaptive statistical iterative reconstruction (ASIR) and improved further with 80 % ASIR. Our new method of creating virtual PCT by combining ultra-low-dose PCT with CTA information yields diagnostic perfusion parametric maps from PCT acquired at 20 or 10 mAs with 80 % ASIR. Effective dose is approximately 0.20 mSv, equivalent to two chest radiographs. (orig.)

  8. Iodide and xenon enhancement of computed tomography (CT) in multiple sclerosis (MS)

    International Nuclear Information System (INIS)

    Radue, E.W.; Kendall, B.E.

    1978-01-01

    The characteristic findings on computed tomography (CT) in multiple sclerosis (MS) are discussed. In a series of 49 cases plain CT was normal in 21 (43%), cerebral atrophy alone was present in 17 (35%) and plaques were visible in 11 (23%). These were most often adjacent to the lateral ventricles (14 plaques) and in the parietal white matter (10 plaques). CT was performed after the intravenous administration of iodide in 16 of these cases. Two patients with low attenuation plaques were scanned with xenon enhancement; the plaques absorbed less xenon than the corresponding contralateral brain substance and additional, previously isodense plaques were revealed. In one case the white matter absorbed much less xenon than normal and its uptake relative to grey matter was reduced. (orig.) [de

  9. Therapeutic response assessment of percutaneous radiofrequency ablation for hepatocellular carcinoma: Utility of contrast-enhanced agent detection imaging

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Choi, Dongil; Lim, Hyo K.; Kim, Seung Hoon; Lee, Won Jae; Kim, Min Ju; Lee, Ji Yeon; Jeon, Yong Hwan; Lee, Jongmee; Lee, Soon Jin; Lim, Jae Hoon

    2005-01-01

    Purpose: To assess the utility of contrast-enhanced agent detection imaging (ADI) in the assessment of the therapeutic response to percutaneous radiofrequency (RF) ablation in patients with hepatocellular carcinoma (HCC). Materials and methods: Ninety patients with a total of 97 nodular HCCs (mean, 2.1 ± 1.3 cm; range, 1.0-5.0 cm) treated with percutaneous RF ablation under the ultrasound guidance were evaluated with contrast-enhanced ADI after receiving an intravenous bolus injection of a microbubble contrast agent (SH U 508A). We obtained serial contrast-enhanced ADI images during the time period from 15 to 90 s after the initiation of the bolus contrast injection. All of the patients underwent a follow-up four-phase helical CT at 1 month after RF ablation, which was then repeated at 2-4 month intervals during a period of at least 12 months. The results of the contrast-enhanced ADI were compared with those of the follow-up CT in terms of the presence or absence of residual unablated tumor and local tumor progression in the treated lesions. Results: On contrast-enhanced ADI, technical success was obtained in 94 (97%) of the 97 HCCs, while residual unablated tumors were found in three HCCs (3%). Two of the three tumors that were suspicious (was not proven) for incomplete ablation were subjected to additional RF ablation. The remaining one enhancing lesion that was suspicious of a residual tumor on contrast-enhanced ADI was revealed to be reactive hyperemia at the 1-month follow-up CT. Therefore; the diagnostic concordance between the contrast-enhanced ADI and 1-month follow-up CT was 99%. Of the 94 ablated HCCs without residual tumors on both the contrast-enhanced ADI and 1-month follow-up CT after the initial RF ablation, five (5%) had CT findings of local tumor progression at a subsequent follow-up CT. Conclusion: Despite its limitations in predicting local tumor progression in the treated tumors, contrast-enhanced ADI is potentially useful for evaluating the

  10. FDG uptake on PET and enhancement on CT or MRI in hepatocellular carcinoma (HCC)

    International Nuclear Information System (INIS)

    Ko, K. H.; Yun, M.; Kim, M. J.; Ryu, Y. H.; Lee, J. D.

    2002-01-01

    To correlate between FDG PET and enhancement pattern on CT and MRI and assess the factors affecting FDG uptake in HCC. Thirty seven nontreated HCC from 34 pts (M:F=30:4, mean age 53) were enrolled. All cases were histologically diagnosed and classified according to Edmonson and Steiner's grading. Tumor FDG uptake was visually assessed on a scale of 0 to 3 compared to the adjacent liver. (0 liver and 3>>liver) and was semi-quantitatively analyzed using SUV. Enhancement pattern on CT and MRI was classified into 3 groups according to signal intensity or density in arterial and portal phase (GroupI: hyperintense-hypointense, GroupII: isointense-hypointense, GroupIII: hypointense-hypointense). Tumor FDG uptake was correlated with enhancement pattern, grade, size and serum aFP level. The tumor ranged from 1.5cm to 20cm. Of the 37 cases, 19(51%) had positive FDG uptake (2 or 3), while 18(49%) were negative (0 or 1). The correlation between FDG uptake and enhancement pattern was statistically insignificant. Lower FDG uptake was associated with lower tumor grade and/or smaller tumor size (P<0.005). FDG uptake of HCC seems to be useful in predicting the differentiation of the tumor and may be prognostic. Although the significance of dynamic enhancement pattern on CT or MRI is yet controversial, it has no specific correlation with FDG uptake and grade on the tumor in this study

  11. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  12. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  13. Diagnostic performance of contrast enhanced CT and 18F-FDG PET/CT in suspicious recurrence of biliary tract cancer after curative resection

    International Nuclear Information System (INIS)

    Lee, Yun-Gyoo; Bang, Yung-Jue; Han, Sae-Won; Oh, Do-Youn; Chie, Eui Kyu; Jang, Jin-Young; Im, Seock-Ah; Kim, Tae-You; Kim, Sun-Whe; Ha, Sung Whan

    2011-01-01

    Because of the late clinical presentation of biliary tract cancer (BTC), only 10% of patients are eligible for curative surgery. Even among those patients who have undergone curative surgery, most patients develop recurrent cancer. This study is to determine the clinical role of 18 F-FDG PET/CT during post-operative surveillance of suspected recurrent BTC based on symptoms, laboratory findings and contrast-enhanced CT (ceCT) findings. We consecutively enrolled 50 patients with BTC who underwent curative surgery. An 18 F-FDG PET/CT was obtained for assessment of recurrence based on clinical suspicion during post-operative surveillance. The final confirmation of recurrence was determined pathologically or clinically. When a pathologic confirmation was impossible or inconclusive, a clinical confirmation was used by radiologic correlation with subsequent follow-up ceCT at a minimum of 3-month intervals. Diagnostic efficacy was evaluated by comparing the results of ceCT and 18 F-FDG PET/CT with the final diagnosis. Among the 50 patients, 34(68%) were confirmed to have a recurrence. PET/CT showed higher sensitivity (88% vs. 76%, p = 0.16) and accuracy (82% vs. 66%, p = 0.11) for recurrence compared to ceCT, even though the difference was not significant. The positive (86% vs. 74%, p = 0.72) and negative predictive values for recurrence (73% vs. 47%, p = 0.55) were not significantly different between PET/CT and ceCT. However, an additional PET/CT on ceCT significantly improved the sensitivity than did a ceCT alone (94% [32/34] for PET/CT on ceCT vs. 76% [26/34] for ceCT alone, p = 0.03) without increasing the specificity, positive predictive value, and negative predictive value. 18 F-FDG PET/CT alone is not more sensitive or specific than ceCT in the detection of recurrent BTC after curative surgery. These results do not reach statistical significance, probably due to the low number of patients. However, an additional 18 F-FDG PET/CT on ceCT significantly improves the

  14. Oxygen-enhanced MRI vs. quantitatively assessed thin-section CT: Pulmonary functional loss assessment and clinical stage classification of asthmatics

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Koyama, Hisanobu; Matsumoto, Keiko; Onishi, Yumiko; Nogami, Munenobu; Takenaka, Daisuke; Matsumoto, Sumiaki; Sugimura, Kazuro

    2011-01-01

    Purpose: The purpose of this study was to prospectively compare the efficacy of oxygen-enhanced MR imaging (O 2 -enhanced MRI) and CT for pulmonary functional loss assessment and clinical stage classification of asthmatics. Materials and methods: O 2 -enhanced MRI, CT and %FEV 1 measurement were used 34 consecutive asthmatics classified into four stages ('Mild Intermittent [n = 7]', 'Mild Persistent [n = 8], 'Moderate Persistent [n = 14]' and 'Severe Persistent [n = 5]'). Relative enhancement ratio maps for every subject were generated, and determine mean relative enhancement ratios (MRERs). Mean lung density (MLD) and the airway wall area (WA) corrected by body surface area (WA/BSA) were also measured on CT. To compare the efficacy of the two methods for pulmonary functional loss assessment, all indexes were correlated with %FEV 1 . To determine the efficacy of the two methods for clinical stage classification, all parameters for the four clinical stages were statistically compared. Results: %FEV 1 showed fair or moderate correlation with all parameters (0.15 ≤ r 2 ≤ 0.30, p 2 -enhanced MRI is as effective as CT for pulmonary functional loss assessment and clinical stage classification of asthmatics.

  15. Oxygen-enhanced MRI for patients with connective tissue diseases: Comparison with thin-section CT of capability for pulmonary functional and disease severity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nishio, Mizuho [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Koyama, Hisanobu [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Seki, Shinichiro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Tsubakimoto, Maho [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nakagami-Gun, Okinawa (Japan); Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2014-02-15

    Purpose: To prospectively and directly compare oxygen-enhanced (O{sub 2}-enhanced) MRI with thin-section CT for pulmonary functional loss and disease severity assessment in connective tissue disease (CTD) patients with interstitial lung disease (ILD). Materials and methods: Thin-section CT, O{sub 2}-enhanced MRI, pulmonary function test and serum KL-6 were administered to 36 CTD patients with ILD (23 men, 13 women; mean age: 63.9 years) and nine CTD patients without ILD (six men, and three women; mean age: 62.0 years). A relative-enhancement ratio (RER) map was generated from O{sub 2}-enhanced MRI and mean relative enhancement ratio (MRER) for each subject was calculated from all ROI measurements. CT-assessed disease severity was evaluated with a visual scoring system from each of the thin-section CT data. MRER and CT-assessed disease severities of CTD patients with and without ILD were then statistically compared. To assess capability for pulmonary functional loss and disease severity assessment in CTD patients, correlations of MRER and CT-assessed disease severity with pulmonary functional parameters and serum KL-6 in all subjects were statistically determined. Results: MRER and CT-assessed disease severity showed significant differences between CTD patients with (MRER: 0.15 ± 0.08, CT-assessed disease severity: 13.0 ± 7.4%) and without ILD (MRER: 0.25 ± 0.06, p = 0.0011; CT-assessed disease severity: 1.6 ± 1.6%, p < 0.0001). MRER and CT-assessed disease severity correlated significantly with pulmonary functional parameters and serum KL-6 in all subjects (0.61 ≤ r ≤ 0.79, p < 0.05). Conclusion: O{sub 2}-enhanced MRI was found to be as useful as thin-section CT for pulmonary functional loss and disease severity assessment of CTD patients with ILD.

  16. Oxygen-enhanced MRI for patients with connective tissue diseases: Comparison with thin-section CT of capability for pulmonary functional and disease severity assessment

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Tsubakimoto, Maho; Sugimura, Kazuro

    2014-01-01

    Purpose: To prospectively and directly compare oxygen-enhanced (O 2 -enhanced) MRI with thin-section CT for pulmonary functional loss and disease severity assessment in connective tissue disease (CTD) patients with interstitial lung disease (ILD). Materials and methods: Thin-section CT, O 2 -enhanced MRI, pulmonary function test and serum KL-6 were administered to 36 CTD patients with ILD (23 men, 13 women; mean age: 63.9 years) and nine CTD patients without ILD (six men, and three women; mean age: 62.0 years). A relative-enhancement ratio (RER) map was generated from O 2 -enhanced MRI and mean relative enhancement ratio (MRER) for each subject was calculated from all ROI measurements. CT-assessed disease severity was evaluated with a visual scoring system from each of the thin-section CT data. MRER and CT-assessed disease severities of CTD patients with and without ILD were then statistically compared. To assess capability for pulmonary functional loss and disease severity assessment in CTD patients, correlations of MRER and CT-assessed disease severity with pulmonary functional parameters and serum KL-6 in all subjects were statistically determined. Results: MRER and CT-assessed disease severity showed significant differences between CTD patients with (MRER: 0.15 ± 0.08, CT-assessed disease severity: 13.0 ± 7.4%) and without ILD (MRER: 0.25 ± 0.06, p = 0.0011; CT-assessed disease severity: 1.6 ± 1.6%, p < 0.0001). MRER and CT-assessed disease severity correlated significantly with pulmonary functional parameters and serum KL-6 in all subjects (0.61 ≤ r ≤ 0.79, p < 0.05). Conclusion: O 2 -enhanced MRI was found to be as useful as thin-section CT for pulmonary functional loss and disease severity assessment of CTD patients with ILD

  17. Pulmonary embolism: Prospective comparison of spiral CT with ventilation - perfusion scintigraphy

    International Nuclear Information System (INIS)

    Mayo Jhon R; Remi Jardin, Martine; Muller Mestor I

    1999-01-01

    The pulmonary thromboembolism (PTE) it is an entity common with great morbidity and mortality that it requires a diagnosis soon and specify. Commonly the ventilation gammagraphy - perfusion has been the used exam of first more frequent line when one suspects the PTE but unfortunately a great quantity of reports is called of intermediate probability, for what requires complementary studies, to confirm or to discard the diagnosis. A prospective study was made with 142 patients that had suspicion of TEP in the hospital of Vancouver (Canada) and in the hospital of Calmette (France), being carried out in all gammagraphy of ventilation-perfusion and helical CT, being only taken to lung angiography to those that not had high clinical suspicion of TEP with gammagraphy or helical CT very suggestive or tuneless, undergoing the results valuation for different observers

  18. Comparison of FDG-PET/CT and contrast-enhanced CT for monitoring therapy response in patients with metastatic breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Riedl, Christopher C.; Ulaner, Gary A.; Jochelson, Maxine S.; Weber, Wolfgang A. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Pinker, Katja [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ong, Leonard T. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Baltzer, Pascal [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); McArthur, Heather L. [Cedars-Sinai Medical Center, Department of Medicine, Breast Oncology, Los Angeles, CA (United States); Goenen, Mithat [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Dickler, Maura [Memorial Sloan Kettering Cancer Center, Department of Medicine, New York, NY (United States)

    2017-08-15

    The aim of this study was to compare fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and contrast-enhanced computed tomography (CE-CT) for the prediction of progression-free survival (PFS) and disease-specific survival (DSS) in patients with stage IV breast cancer undergoing systemic therapy. Sixty-five patients with metastatic breast cancer treated with first- or second-line systemic therapy in prospective clinical trials were included. Response to treatment was evaluated by Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 for CE-CT and by PET Response Criteria in Solid Tumors (PERCIST), respectively. All responders by RECIST (n = 22) were also responders by PERCIST, but 40% (17/43) of non-responders by RECIST were responders by PERCIST. Responses according to RECIST and PERCIST both correlated with PFS, but PERCIST showed a significantly higher predictive accuracy (concordance index for PFS: 0.70 vs. 0.60). One-year PFS for responders vs. non-responders by RECIST was 59% vs. 27%, compared to 63% vs. 0% by PERCIST. Four-year DSS of responders and non-responders by RECIST was 50% and 38%, respectively (p = 0.2, concordance index: 0.55) as compared to 58% vs. 18% for PERCIST (p < 0.001, concordance index: 0.65). Response on PET/CT was also a significantly better predictor for DSS than disease control on CE-CT. In patients with metastatic breast cancer, tumor response on PET/CT appears to be a superior predictor of PFS and DSS than response on CE-CT. Monitoring tumor response by PET/CT may increase the power of clinical trials using tumor response as an endpoint, and may improve patient management in clinical routine. (orig.)

  19. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    International Nuclear Information System (INIS)

    Kim, You Sung; Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun; Lee, Soo Rim; Hwang, Seong Su; Lim, Yeon Soo; Park, Jeong Mi

    2017-01-01

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT

  20. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  1. Non-hodgkin lymphoma containing low attenuation area at enhanced CT : correlation with histopathologic typing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hoon; Kim, Hyung Jin; Ahn, In Oak; Chung, Sung Hoon [College of Medicine, Gyeongsang National University, Jinju (Korea, Republic of); Park, Ji Hyun [Masan Koryo General Hospital, Masan (Korea, Republic of)

    1994-12-15

    To evaluate the frequently of low attenuation area in enhanced CT scans of non-Hodgkin lymphoma(NHL) and to find out if there is any pertinent relationship between this and the histopathologic classification. The authors reviewed CT scans in the newly-diagnosed 53 patients with NHL. We defined the low attenuation area as the one with CT attenuation value lower than that of the muscle, surrounding lesion, or other lymph nodes after contrast enhancement. NHL with the low attenuation areas were correlated with the histopathologic findings according to the classification based on the Working Formulation and the frequency of the lesion was evaluated. Of the 53 patients, the low attenuation area was found in 13 patients (25%) at CT. The histopathologic classification could be made in 12 patients, among whom one patient was classified as low-grade, six as intermediate-grade, and five as high-grade. Concerning the specific cell typing, the diffuse large cell type was most common in intermediate-grade NHL seen in five patients and the large cell, immunoblastic type was most common in high-grade NHL seen in three patients. The authors concluded that the low attenuation area within lymphoma is not an infrequent finding at CT, and there was no statistically significant correlation between this finding and the prognostic grading of the Working Formulation.

  2. The Effect of the Degree of Luminal Contrast-Enhancement on CT Measurement of Plaque Size: A Comparison with T1-weighted Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Hur, Jin; Lee, Hye Jeong; Kim, Young Jin; Choe, Kyu Ok; Kim, Tae Hoon

    2010-01-01

    We studied early and delayed contrast-enhanced CT to determine the effects of the degree of luminal enhancement on the measurement of plaque size compared to T1-weighted MRI. T1-weighted MRI and a two-phase contrast-enhanced CT was performed in 5 New Zealand white rabbits with atherosclerosis. Early-phase images were acquired during an expected peak enhancement period of the lumen; delayed-phase images were acquired 240 sec after administration of the contrast media. Anteroposterior and lateral luminal diameters (APD, LD), luminal area (LA), total vessel area (TVA), and plaque area (PA) of the aorta were measured on MRI and CT, respectively and compared to each other. A total of 78 slices of the aorta were analyzed. PA, measured on T1-weighted MR images, was significantly greater than PA for both early-phase and delayed-phase CT (p 2 (p 2 (p 2 (p = 0.159) for MRI vs. early-phase CT, MRI vs. delayed-phase CT, and early-phase CT vs. delayed-phase CT, respectively. Different luminal densities by contrast enhancement do not affect the CT measurement of plaque area for the detection of obstructive coronary artery disease

  3. Bearing capacity of helical pile foundation in peat soil from different, diameter and spacing of helical plates

    Science.gov (United States)

    Fatnanta, F.; Satibi, S.; Muhardi

    2018-03-01

    In an area dominated by thick peat soil layers, driven piles foundation is often used. These piles are generally skin friction piles where the pile tips do not reach hard stratum. Since the bearing capacity of the piles rely on the resistance of their smooth skin, the bearing capacity of the piles are generally low. One way to increase the bearing capacity of the piles is by installing helical plates around the pile tips. Many research has been performed on helical pile foundation. However, literature on the use of helical pile foundation on peat soil is still hardly found. This research focus on the study of axial bearing capacity of helical pile foundation in peat soil, especially in Riau Province. These full-scale tests on helical pile foundation were performed in a rectangular box partially embedded into the ground. The box is filled with peat soil, which was taken from Rimbo Panjang area in the district of Kampar, Riau Province. Several helical piles with different number, diameter and spacing of the helical plates have been tested and analysed. The tests result show that helical pile with three helical plates of uniform diameter has better bearing capacity compared to other helical piles with varying diameter and different number of helical plates. The bearing capacity of helical pile foundation is affected by the spacing between helical plates. It is found that the effective helical plates spacing for helical pile foundation with diameter of 15cm to 35cm is between 20cm to 30cm. This behaviour may be considered to apply to other type of helical pile foundations in peat soil.

  4. Reducing radiation dose in liver enhanced CT scan by setting mAs according to plain scan noise

    International Nuclear Information System (INIS)

    Yang Shangwen; He Jian; Yang Xianfeng; Zhou Kefeng; Xin Xiaoyan; Hu Anning; Zhu Bin

    2013-01-01

    Objective: To investigate the feasibility of setting mAs in liver enhanced CT scan according to plain scan noise with fixed mA CT scanner, in order to reduce the radiation dose. Methods: One hundred continuous patients underwent liver enhanced CT scan (group A) prospectively. Two hundred and fifty mAs was used in plain and enhanced CT scans. Noises of plain and venous phase CT images were measured, and the image quality was evaluated. The equation between mAs of enhanced scan and noise of plain scan image was derived. Another 100 continuous patients underwent liver enhanced CT scan (group B). Enhanced scan mAs was calculated from noise on plain scan by using the equation above. Noises on venous phase images were measured and the image quality was measured. Based on body mass index (BMI), patients in groups A and B were divided into three subgroups respectively: BMI < 18.5 kg/m 2 , 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 and BMI ≥ 25.0 kg/m 2 . Image quality score was compared with nonparametric rank sum test, CT dose index (CTDI) and effective dose (ED) were measured and compared between each subgroup with 2 independent samples t or t' test. Results: The equation between enhanced scan mAs (mAsX) and plain scan noise (SDp) was as follows: mAsX = mAs1 × [(0.989 × SDp + 1.06) /SDx] 2 , mAs1 = 250 mAs, SDx = 13. In patients with BMI < 18.5 kg/m 2 , ED of group A [(6.86 ± 0.38) mSv, n = 12] was significantly higher than group B [(2.66 ± 0.46) mSv, n = 10)] (t = 18.52, P < 0.01). In patients with 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 , ED of group A [(7.08 ± 0.91) mSv, n = 66] was significantly higher than group B [(4.50 ± 1.41) mSv, n = 73] (t' = 10.57, P < 0.01). In patients with BMI ≥ 25.0 kg/m 2 , there was no significant difference between EDs of group A (7.54 ± 0.62 mSv, n = 22) and group B [(8.19 ± 3.16) mSv, n = 17] (t' = 0.89, P = 0.39). Image quality of 5 patients in group A and none in group B did not meet the diagnostic requirement

  5. Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

    International Nuclear Information System (INIS)

    Zhang Yu; Yap, Pew-Thian; Wu Guorong; Feng Qianjin; Chen Wufan; Lian Jun; Shen Dinggang

    2013-01-01

    Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors’ algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors’ algorithm increases peak signal-to-noise ratio by 3–4 dB and the structural similarity index by 3%–5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It

  6. Contrast-enhanced computed tomography does not improve the diagnostic value of parathyroid dual-phase MIBI SPECT/CT

    DEFF Research Database (Denmark)

    Andersen, Trine B; Aleksyniene, Ramune; Boldsen, Søren K

    2018-01-01

    OBJECTIVE: The aim of this study was to investigate the contribution of contrast-enhanced computed tomography (CE-CT) to the localization of parathyroid adenomas compared with the dual-phase Tc-99m MIBI SPECT with low-dose CT (LD-CT). PATIENTS AND METHODS: This retrospective study included...... consecutive patients with primary hyperparathyroidism who underwent a preoperative dual-phase MIBI SPECT/CT followed by surgical resection. The standard of care was dual-phase MIBI SPECT/CT, acquired with LD-CT in the early phase and CE-CT in the late phase (SPECT/CE-CT). The presence and localization...... of positive sites were extracted from study reports. To examine the role of CE-CT, patient cases were independently re-reviewed, with the early LD-CT fused with early and late SPECT (SPECT/LD-CT). The two SPECT/CT methods were compared for sensitivity, and the positive predictive value and histopathology were...

  7. CT enhancement of acute cerebral infarction following long-term continuous contrast infusion

    International Nuclear Information System (INIS)

    Ito, Umeo; Seida, Mitsuru; Tomida, Shuichi; Inaba, Yutaka.

    1985-01-01

    In this experimental study, we employed a long-term (3 hours) continuous-drip infusion of the contrast medium (200 ml of meglumine amidtrizoate) rather than the conventional bolus injection. On admission, four-vessel angiography was performed on all 14 patients. Within 3 days after the onset of the disease, CT scan was carried out repeatedly just prior to contrast infusion, immediately after the end of the continuous-contrast infusion, and additionally, in 4 cases, 3 hours after the end of the contrast infusion. The Haunsfield number was calculated in 3 regions of interest (Radius 5) in the infarction. Positive enhancement was observed in 10 out of the 14 patients (71 %). Among them, 4 out of 5 patients in whom no vascular obstraction on angiography, but marked low-density areas with a mass effect on CT were observed, showed moderate to marked enhancement. In these 4 patients, a temporary cerebral ischemia due to vascular embolization was considered. From the other 4 patients in whom the additional CT scan was performed 3 hours after the end of the contrast infusion, a blood sample was obtained at each of the 3 CT scannings. The iodine concentrations of the blood samples were measured, and their Haunsfield numbers were calculated in the water phantom. The above two parameters were well correlated in a linear function. Among the 4 patients, Gado's tissue-blood ratio (the Haunsfield number of the CT lesion is divided by that of the blood sample) was more than 17.2 % immediately after, and more than 54.7 % 3 hours after, the contrast infusion. Thus, we could conclude that the break-down of the BBB which was demonstrated by a long-term high-blood-concentration level of the contrast medium is an earlier event in human cerebral infarction than is usually accepted. The findings are compatible with our results in animal experiments. (author)

  8. Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

    International Nuclear Information System (INIS)

    Driscoll, B.; Keller, H.; Coolens, C.

    2011-01-01

    Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments (σ/μ 2 ) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The

  9. Triphasic contrast enhanced CT simulation with bolus tracking for pancreas SBRT target delineation.

    Science.gov (United States)

    Godfrey, Devon J; Patel, Bhavik N; Adamson, Justus D; Subashi, Ergys; Salama, Joseph K; Palta, Manisha

    Bolus-tracked multiphasic contrast computed tomography (CT) is often used in diagnostic radiology to enhance the visibility of pancreas tumors, but is uncommon in radiation therapy pancreas CT simulation, and its impact on gross tumor volume (GTV) delineation is unknown. This study evaluates the lesion conspicuity and consistency of pancreas stereotactic body radiation therapy (SBRT) GTVs contoured in the different contrast phases of triphasic CT simulation scans. Triphasic, bolus-tracked planning CT simulation scans of 10 consecutive pancreas SBRT patients were acquired, yielding images of the pancreas during the late arterial (LA), portal venous (PV), and either the early arterial or delayed phase. GTVs were contoured on each phase by a gastrointestinal-specialized radiation oncologist and reviewed by a fellowship-trained abdominal radiologist who specializes in pancreatic imaging. The volumes of the registered GTVs, their overlap ratio, and the 3-dimensional margin expansions necessary for each GTV to fully encompass GTVs from the other phases were calculated. The contrast difference between tumor and normal pancreas was measured, and 2 radiation oncologists rank-ordered the phases according to their value for the lesion-contouring task. Tumor-to-pancreas enhancement was on average much larger for the LA and PV than the delayed phase or early arterial phases; the LA and PV phases were also consistently preferred by the radiation oncologists. Enhancement differences among the phases resulted in highly variable GTV volumes with no observed trends. Overlap ratios ranged from 18% to 75% across all 3 phases, improving to 43% to 91% when considering only the preferred LA and PV phases. GTV expansions necessary to encompass all GTVs ranged from 0.3 to 1.8 cm for all 3 phases, improving slightly to 0.1 to 1.4 cm when considering just the LA and PV phases. For pancreas SBRT, we recommend combining the GTVs from a multiphasic CT simulation with bolus-tracking, including

  10. Patients with liver FNH and HCC patients with negative AFP: plain and dynamic enhanced MRI and CT findings

    Directory of Open Access Journals (Sweden)

    LI Mingtong

    2015-05-01

    Full Text Available ObjectiveTo investigate plain and dynamic enhanced magnetic resonance imaging (MRI and computed tomography (CT findings in patients with focal nodular hyperplasia (FNH of the liver and hepatocellular carcinoma (HCC patients with negative alpha-fetoprotein (AFP. MethodsA statistical analysis was performed on the clinical data of 124 cases of liver tumor admitted to Beijing Miyun County Hospital from April 2012 to April 2014. ResultsFifty-five of the 74 patients with FNH underwent CT examination, among whom 38 patients received three-phase dynamic enhanced scan and 16 received only plain scan; 62 cases had plain and enhanced MRI with the application of contrast agent Gd-BOPTA in 42 patients. Among the 50 HCC patients with negative AFP, CT examination was performed in 40 and 10 only had plain scan; 46 patients received plain and enhanced MRI with the use of contrast agent Gd-BOPTA in 30. Delayed scan after 1-2 h demonstrated low signal in 30 lesions of the 30 cases. ConclusionFor patients with liver FNH and AFP-negative HCC patients, their plain and dynamic enhanced MRI and CT scan have respective characteristics. A combination of multiple examination methods can significantly improve diagnostic yield of the two diseases.

  11. Investigations into the use of SNOMED CT to enhance an OpenMRS health information system

    CSIR Research Space (South Africa)

    Halland, K

    2011-07-01

    Full Text Available In this paper, the authors discuss the advantages of using formal medical ontologies to enhance health information systems. In particular, they consider the suitability of the medical ontology Snomed CT for enhancing a health information system...

  12. Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study.

    Science.gov (United States)

    Makeev, Andrey; Glick, Stephen J

    2017-12-01

    Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.

  13. Estimation of enhanced cancer risk with 18FDG PET/CT investigations

    International Nuclear Information System (INIS)

    Kaushik, Aruna; Mishra, Anil K.; Sharma, Rajnish; Mondal, Anupam; Dwarakanath, B.S.

    2014-01-01

    18 F-Fluorodeoxyglucose ( 18 FDG) Positron Emission Tomography/Computed Tomography (PET/CT) investigation involves internal administration of 18 FDG and use of CT X-rays for the purpose of obtaining functional and anatomical information of a patient. However, the radiation exposure from undergoing PET/CT investigation may enhance the risk of cancer incidence as per the Linear-No-Threshold (LNT) model. The objective of the present study was to quantify the risk of cancer incidence associated with radiation exposure from 18 FDG PET/CT investigations. The organ doses from internally administered 18 FDG were estimated using OLINDA/EXM Code by performing dynamic PET scans in different regions of the body in a total of forty-nine patients. Organ doses from the CT component were calculated using the software CT-Expo. The associated cancer risk was calculated in terms of life time risk of cancer incidence resulting from a specified dose of ionizing radiation and was expressed in terms of Lifetime Attributable Risk (LAR). LAR values and the organ doses estimated for males and females were used to estimate the lifetime risk of cancer incidence from whole body 18 FDG PET/CT scan. Since from 18 FDG whole body PET/CT investigations, various tissues of the body receive substantially different doses, the site specific risk of cancer incidence was estimated and summed to obtain the total risk. This was compared with the baseline lifetime risk of cancer incidence in Indian population. LAR of cancer incidence was observed to be relatively higher in females as compared to males. The risk estimates ranged from 0.36% to 0.49% for a 20 year old male and 0.58% to 0.79% for a 20 year old female and were observed to be higher in younger ages and decreased with age. 18 FDG whole body PET/CT investigation was observed to be associated with non-negligible radiation risk as compared to the risks associated with other diagnostic modalities. (author)

  14. Xe enhanced CT in the human newborn infant

    International Nuclear Information System (INIS)

    Fuse, Yozen; Nemoto, Yuko; Shimizu, Mitsumasa; Uga, Naoki; Tada, Hiroshi; Fujii, Toshi; Machida, Keiichi; Kikuchi, Hideo; Izumi, Shigemitsu.

    1990-01-01

    With a cranial computed tomography (CT) using stable xenon gas as a diffusible tracer, we measured regional cerebral blood flow (rCBF) in 6 newborn infants with a variety of neurological abnormalities. Gestational ages and birthweights were 35 to 43 weeks and 2436 to 3540 g, respectively. Four infants exhibited hypoxic-ischemic encephalopathy (HIE), one infant had subdural hemorrhage and the other one was the infant with hyponatremia. A baseline CT was done during denitrogenation by 100% oxygen breathing and then a mixture of 35% xenon and 65% oxygen was breathed for 6 minutes. Six scans were obtained during the inhalation period then the infant was returned to breathing 100% oxygen and additional 7 scans were taken. Four samples of arterial blood were collected every 2 minutes before and during inhalation of the xenon gas. A rCBF was calculated with the changes of Hounsfield units in brain tissue and arterial blood. Relatively high blood flows in the region of the basal nuclei as well as decreased flows in the occipital white matter were observed in the infants with HIE. In an infant with subdural hemorrhage, the blood flows were markedly reduced in the areas adjacent to the lesion, including the basal nuclei, and frontal white matter in the opposite hemisphere. Xenon-enhanced CT by inhaling low concentration of the xenon gas enables to measure rCBF in the human newborn infants without no obvious side effect. (author)

  15. Dual-Energy CT in Enhancing Subdural Effusions that Masquerade as Subdural Hematomas: Diagnosis with Virtual High-Monochromatic (190-keV) Images.

    Science.gov (United States)

    Bodanapally, U K; Dreizin, D; Issa, G; Archer-Arroyo, K L; Sudini, K; Fleiter, T R

    2017-10-01

    Extravasation of iodinated contrast into subdural space following contrast-enhanced radiographic studies results in hyperdense subdural effusions, which can be mistaken as acute subdural hematomas on follow-up noncontrast head CTs. Our aim was to identify the factors associated with contrast-enhancing subdural effusion, characterize diffusion and washout kinetics of iodine in enhancing subdural effusion, and assess the utility of dual-energy CT in differentiating enhancing subdural effusion from subdural hematoma. We retrospectively analyzed follow-up head dual-energy CT studies in 423 patients with polytrauma who had undergone contrast-enhanced whole-body CT. Twenty-four patients with enhancing subdural effusion composed the study group, and 24 randomly selected patients with subdural hematoma were enrolled in the comparison group. Postprocessing with syngo.via was performed to determine the diffusion and washout kinetics of iodine. The sensitivity and specificity of dual-energy CT for the diagnosis of enhancing subdural effusion were determined with 120-kV, virtual monochromatic energy (190-keV) and virtual noncontrast images. Patients with enhancing subdural effusion were significantly older (mean, 69 years; 95% CI, 60-78 years; P subdural effusions was reached within the first 8 hours of contrast administration with a mean of 0.98 mg/mL (95% CI, 0.81-1.13 mg/mL), and complete washout was achieved at 38 hours. For the presence of a hyperdense subdural collection on 120-kV images with a loss of hyperattenuation on 190-keV and virtual noncontrast images, when considered as a true-positive for enhancing subdural effusion, the sensitivity was 100% (95% CI, 85.75%-100%) and the specificity was 91.67% (95% CI, 73%-99%). Dual-energy CT has a high sensitivity and specificity in differentiating enhancing subdural effusion from subdural hematoma. Hence, dual-energy CT has a potential to obviate follow-up studies. © 2017 by American Journal of Neuroradiology.

  16. The role of unenhanced helical CT in the evaluation of suspected renal colic and atypical abdominal pain in children

    International Nuclear Information System (INIS)

    Eshed, Iris; Witzling, Michaela

    2002-01-01

    Background: Urolithiasis in children has a different pattern of presentation than in adults and its incidence is lower. Unenhanced helical CT (UEHCT) for suspected urinary tract calculi in adults has high sensitivity and specificity for detecting even minute calculi. UEHCT has been proposed as a fast and sensitive method for identifying urinary stones in children. However, to our knowledge, the role of UEHCT and its value in the diagnostic work-up of urinary stones in children has not been studied. Objective: To evaluate the significance of UEHCT as a diagnostic tool for urinary stones in children. Materials and methods: We retrospectively analysed data on 20 children who underwent UEHCT during 1999-2000. Results: Findings on UEHCT were significant in establishing a diagnosis in only seven patients and only three were shown to have urinary stones. Only one significant finding was found in the group who underwent UEHCT without prior US. US performed prior to UEHCT was a significant screening tool, and when results were equivocal, UEHCT further helped in establishing diagnosis. Conclusions: We propose that US be the first imaging modality in children with suspected urolithiasis. When the result of this examination is uncertain or abnormal, UEHCT will probably add further information which will contribute to the diagnosis. (orig.)

  17. Hybrid imaging with contrast enhanced CT scan: A nuclear physician's point of view

    International Nuclear Information System (INIS)

    Houzard, C.; Tychyj-Pinel, C.; Defez, D.; Valette, P.J.; Giammarile, F.; Houzard, C.; Valette, P.J.; Giammarile, F.

    2010-01-01

    The ongoing development of hybrid imaging, with physical association of CT scan and PET or SPECT scan, allows integrating morphological and functional information on a single exam. This important technological evolution changes diagnostic and therapeutic strategy in a major manner, essentially in oncology. The possibility to inject intravenously iodinated contrast media in order to enhance CT image contrast is still a controversial question in France. We present our experience in this domain by approaching technical problems and diagnostic advantages. (authors)

  18. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and

  19. A qualitative diagnosis of stapes lesions by helical 3-dimensional CT

    International Nuclear Information System (INIS)

    Kawaue, Akifumi; Yamanaka, Noboru; Kuki, Kiyonori; Nishimura, Michihiko

    2001-01-01

    To evaluate the usefulness of 3D-CT combined with super-selective stapes's image processing (3D-SS) for the qualitative diagnosis of stapes lesions, a new parameter, the crus index, was designed and applied to CT image diagnosis of conductive hearing loss. The crus index was designed as a new parameter indicating the average of changing rate of cross section area of crus image when the lower thresholed of CT window width reduced by 100 H.U.. The crus index was calculated with 3D-SS in 5 ears with otosclerosis, in 5 ears with eroded long process of incus or crus of stapes, an ear with facial neurinoma (susp), an ear with soft density tissue on only stapes and 6 control ears and the diagnostic usefulness was evaluated as comparing the intra-/post-operative diagnosis. The crus index was significantly higher in ears with eroded long process of incus or crus of stapes (3.58+1.36) than otosclerosis (1.33+0.35) or controls (1.44+0.3). These data suggest that the crus index using 3D-SS may be a useful parameter in diagnosing conductive hearing loss. (author)

  20. Emergency department CT screening of patients with nontraumatic neurological symptoms referred to the posterior fossa: comparison of thin versus thick slice images.

    Science.gov (United States)

    Kamalian, Shervin; Atkinson, Wendy L; Florin, Lauren A; Pomerantz, Stuart R; Lev, Michael H; Romero, Javier M

    2014-06-01

    Evaluation of the posterior fossa (PF) on 5-mm-thick helical CT images (current default) has improved diagnostic accuracy compared to 5-mm sequential CT images; however, 5-mm-thick images may not be ideal for PF pathology due to volume averaging of rapid changes in anatomy in the Z-direction. Therefore, we sought to determine if routine review of 1.25-mm-thin helical CT images has superior accuracy in screening for nontraumatic PF pathology. MRI proof of diagnosis was obtained within 6 h of helical CT acquisition for 90 consecutive ED patients with, and 88 without, posterior fossa lesions. Helical CT images were post-processed at 1.25 and 5-mm-axial slice thickness. Two neuroradiologists blinded to the clinical/MRI findings reviewed both image sets. Interobserver agreement and accuracy were rated using Kappa statistics and ROC analysis, respectively. Of the 90/178 (51 %) who were MR positive, 60/90 (66 %) had stroke and 30/90 (33 %) had other etiologies. There was excellent interobserver agreement (κ > 0.97) for both thick and thin slice assessments. The accuracy, sensitivity, and specificity for 1.25-mm images were 65, 44, and 84 %, respectively, and for 5-mm images were 67, 45, and 85 %, respectively. The diagnostic accuracy was not significantly different (p > 0.5). In this cohort of patients with nontraumatic neurological symptoms referred to the posterior fossa, 1.25-mm-thin slice CT reformatted images do not have superior accuracy compared to 5-mm-thick images. This information has implications on optimizing resource utilizations and efficiency in a busy emergency room. Review of 1.25-mm-thin images may help diagnostic accuracy only when review of 5-mm-thick images as current default is inconclusive.

  1. CT staging of renal cell carcinoma

    International Nuclear Information System (INIS)

    Spina, Juan C.; Garcia, Adriana T.; Rogondino, Jose; Spina, Juan C. h; Vidales, Valeria; Troiani, Guillermo; Iotti, Alejandro; Venditti, Julio

    2002-01-01

    Objective: To assess the usefulness of computerized tomography (CT) in the characterization of renal masses, in order to stage them, determine their prognosis and their appropriate clinical and/or surgical management. Material and Methods: Between 1988 and 2001, we selected 63 patients with renal tumors that had been examined by pathology. Patient's ages ranged from 16 to 88 years (25 women, 38 men). The studies were performed with a sequential helical CT, using 5 mm thickness sections every 5mm evaluating the cortico medullar and nephrographic phases. Renal tumors were characterized and staged without any knowledge about the pathological findings; subsequently the tomographic characteristics were compared to such findings. The following characteristics were evaluated: 1) mixed solid-cystic nature; 2) size; 3) borders; 4) enhancement; 5) necrosis; 6) hemorrhage; 7) central scar; 8) presence of fat; 9) collecting system; 10) capsular invasion; 11) perirenal fat invasion; 12) vessels; 13) Gerota's fascia; 14) lymph nodes; and 15) local and/or distant metastases. Results: Of the 63 tumors, 2 were complicated cysts; of the 61 remaining tumors, 10 were angiomyolipomas, 1 was a renal lymphoma, 1 was a focal xantogranulomatose pyelonephritis, 1 was a metanephric adenoma, 3 papillary renal cell carcinoma (RCC), 4 transitional cell tumors, 4 oncocytomas, 37 clear cell renal carcinoma. The CT could correctly characterize the 2 cystic tumors as such, as well as the 9 angiomyolipomas and the 4 transitional cell tumors. The 48 other tumors (1 angiomyolipoma, 1 lymphoma, 1 focal xantogranulomatose pyelonephritis, 1 metanephric adenoma, 3 papillary RCC, 4 oncocytomas, and 37 cell renal carcinomas) remaining were characterized as renal adenocarcinomas and CT staged. Conclusion: CT is a useful method to characterize renal masses since it determines their solid-cystic or fatty structure; aiding in many cases to define a surgical treatment. For the CT staging of renal tumors, the

  2. Change in contrast enhancement of HCC on 1-month follow-up CT after local radiotherapy: An early predictor of final treatment response

    International Nuclear Information System (INIS)

    Kim, Eun Young; Choi, Dongil; Lim, Do Hoon; Lee, Won Jae; Yoo, Byung Chul; Paik, Seung Woon

    2009-01-01

    Background: The purpose of this study was to evaluate the change in contrast enhancement of HCC on 1-month follow-up CT after local radiotherapy (RT) as an early predictor of final treatment response. Materials: Fifty patients who underwent local RT for HCCs had both pre-RT and post-RT CT scans including 1-month follow-up CT. We assessed the final treatment response by using the change in maximal tumor size on 6-12-month follow-up CT scan after RT. We also evaluated the change in tumor enhancement between pre-RT and 1-month follow-up CT scans. Results: A final treatment response was achieved in 27 (54%) of 50 patients, who showed either a complete response (n = 11) or a partial response (n = 16). Compared with non-responsive patients (n = 23), responsive patients showed a significant decrease in tumor enhancement on 1-month follow-up CT after RT in both objective and subjective analyses (each P < 0.001). Conclusion: The change in contrast enhancement of HCC seen on the 1-month follow-up CT in patients after local RT may be used as an early predictor of final treatment response.

  3. Permanent-magnet helical undulator for a millimeter-wave free electron laser

    International Nuclear Information System (INIS)

    Lee, Jongmin; Jeong, Young-Uk; Lee, Byung-Cheol; Kim, Sun-Kook; Cho, Sung-Oh

    1995-01-01

    Permanent-magnet helical undulator for a millimeter-wave free-electron laser was designed and constructed. The configuration of the undulator is based on bifilar-type permanent-magnet helical undulator and Halbach-type planar undulator. This new configuration shows enhanced magnetic field and low field error. Period, total length and peak magnetic-field amplitude of the undulator is 36 mm, 900 mm and 1.44 kG, respectively. Adiabatic tapering of the magnetic field in end sides of the undulator was achieved using stepped soft-iron tubes. (author)

  4. Accuracy and role of contrast-enhanced CT in diagnosis and surgical planning in 88 soft tissue tumours of extremities

    International Nuclear Information System (INIS)

    Verga, Lucia; Robiati, Sara; De Marchi, Armanda; Martorano, Domenico; Faletti, Carlo; Brach del Prever, Elena Maria; Linari, Alessandra; Boffano, Michele; Piana, Raimondo

    2016-01-01

    Soft tissue tumours (STT) require accurate diagnosis in order to identify potential malignancies. Preoperative planning is fundamental to avoid inadequate treatments. The role of contrast-enhanced computed tomography (CT) for local staging remains incompletely assessed. Aims of the study were to evaluate CT accuracy in discriminating active from aggressive tumours compared to histology and evaluate the role of CT angiography (CTA) in surgical planning. This retrospective cohort series of 88 cases from 1200 patients (7 %) was locally studied by contrast-enhanced CT and CTA in a referral centre: 74 malignant tumours, 14 benign lesions. Contrast-enhancement patterns and relationship of the mass with major vessels and bone were compared with histology on surgically excised samples. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) were evaluated in discriminating active from aggressive tumours. Sensitivity in differentiating aggressive tumours from active lesions was 89 %, specificity 84 %, PPV 90 %, NPV 82 %. The relationship between mass and major vessels/bone was fundamental for surgical strategy respectively in 40 % and in 58 % of malignant tumours. Contrast-enhanced CT and CTA are effective in differentiating aggressive masses from active lesions in soft tissue and in depicting the relationship between tumour and adjacent bones and major vessels. (orig.)

  5. Dynamic contrast-enhanced MR imaging in osteoid osteoma: relationships with clinical and CT characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Pottecher, P. [Hopital Lariboisiere, AP-HP, Department of Osteoarticular Radiology, Paris (France); Hopital du Bocage, Department of Vascular, Oncologic and Interventional Radiology, Dijon (France); Sibileau, E.; Hamze, B.; Parlier, C.; Laredo, J.D.; Bousson, V. [Hopital Lariboisiere, AP-HP, Department of Osteoarticular Radiology, Paris (France); Aho, S. [Hopital du Bocage, Hospital Hygiene and Epidemiology unit, Dijon (France)

    2017-07-15

    To correlate dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) features to clinical and computed tomography (CT) morphological features of osteoid osteoma (OO). Our institutional review board approved this retrospective study, waiving the need for informed consent. We included the 102 patients treated with interstitial laser ablation for histologically documented OO at our institution in 2008-2013. DCE-MRI variables were the time-enhancement pattern and rising slope (Slope{sub rise}) and CT variables were the bone and segment involved (OO{sub bone} and OO{sub segment,} respectively), OO location relative to the native cortex (OO{sub cortex}), nidus surface area, vessel sign, and largest neighboring-vessel diameter (Dmax{sub vessel}). Descriptive statistics and correlations linking DCE-MRI findings to clinical and CT characteristics were computed. DCE-MRI showed early arterial peak enhancement in 95 (93%) cases, with a mean Slope{sub rise} of 9.30 ± 8.10. CT visualized a vessel sign in 84 (82%) cases with a mean Dmax{sub vessel} of 1.10 ± 0.60 mm. By univariate analysis, Slope{sub rise} correlated significantly with pain duration and Dmax{sub vessel} (r = 0.30, P = 0.003; and r = 0.22, P = 0.03; respectively). Analysis of variance showed that Slope{sub rise} correlated significantly with OO{sub bone} (P < 0.001), with a steeper slope for OOs located in short or flat bones. This study suggests more abundant vascularization of OOs with long-lasting pain and location on short or flat bones. (orig.)

  6. Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya

    2015-06-01

    The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Image quality and dose optimisation for infant CT using a paediatric phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, Jack W.; Phelps, Andrew S.; Courtier, Jesse L.; Gould, Robert G.; MacKenzie, John D. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2016-05-15

    To optimise image quality and reduce radiation exposure for infant body CT imaging. An image quality CT phantom was created to model the infant body habitus. Image noise, spatial resolution, low contrast detectability and tube current modulation (TCM) were measured after adjusting CT protocol parameters. Reconstruction method (FBP, hybrid iterative and model-based iterative), image quality reference parameter, helical pitch and beam collimation were systematically investigated for their influence on image quality and radiation output. Both spatial and low contrast resolution were significantly improved with model-based iterative reconstruction (p < 0.05). A change in the helical pitch from 0.969 to 1.375 resulted in a 23 % reduction in total TCM, while a change in collimation from 20 to 40 mm resulted in a 46 % TCM reduction. Image noise and radiation output were both unaffected by changes in collimation, while an increase in pitch enabled a dose length product reduction of ∝6 % at equivalent noise. An optimised protocol with ∝30 % dose reduction was identified using model-based iterative reconstruction. CT technology continues to evolve and require protocol redesign. This work provides an example of how an infant-specific phantom is essential for leveraging this technology to maintain image quality while reducing radiation exposure. (orig.)

  8. Multiphasic contrast-enhanced CT and MRI findings of adult mesoblastic nephroma: A report of two cases

    Directory of Open Access Journals (Sweden)

    Yuqin Ding

    2013-01-01

    Full Text Available Mesoblastic nephroma (MN presenting in an adult is extremely rare. The computed tomography (CT and magnetic resonance imaging (MRI features of this tumor in adulthood have not been widely reported. We present two additional cases of adult MN and describe the multiphasic contrast-enhanced CT and MRI findings.

  9. TRIPLE PHASE SPIRAL C.T. IN THE EVALUATION OF HEPATIC MASSES

    Directory of Open Access Journals (Sweden)

    Prasad

    2015-10-01

    Full Text Available BACKGROUND AND OBJECTIVE : The goal of the study is to determine the value of various phases of Triple, Helical CT, Hepatic arterial Phase (HAP, Portal venous phase (PVP and Equilibrium Phase (EP, is the detection and characterization of Hepatic Lesions and to evaluate whether u nenhanced and hepatic arterial phases when used in conjunction with porto venous phase would lead to detection of greater number of lesions or better characterization of lesion. METHODOLOGY : The study population consists of 50 Patients aged between 30 Years and 80 Years were examined with multiphase (plain, hepatic arterial, portal venous and equilibrium phases. Spiral CT of liver. Patients were referred for CT scan when liver diseases were suspected clinically, if ultrasound and other previous investi gations revealed lesions which had to be further evaluated by spiral CT and to detect liver metastases in known cases of primary extra hepatic malignancy. CT TECHNIQUE: Helical scanning of liver with Toshiba astein s4, continuous spiral run and the images were reconstructed at 5mm intervals. Contrast material 100ml was injected through 18 or 20G catheter at the rate of 3ml per second using automatic medrad power injector. Non - ionic contrast [IOHEXOl – 300mg perml was used in all the patients]. After obtaine d unenhanced CT scan HAP scanning was initiated 25 seconds after initiation of contrast injection. Portal venous phase scanning was initiated 60 - 65 seconds after start of contrast injection. Equilibrium phase scanning was initiated after 180 seconds after the start of contrast injection. IMAGE EVALUATION: All the images of 4 phases were reviewed. First Step : The presence, appearance and enhancement of each Lesion were noted in all phases and lesion were described Isodense, Hypodense Hyperdense based on thei r attenuation relative to liver parenchyma during that phase of scanning. Based on enhancement pattern of the lesion during various phases they were

  10. A prolapsed cervical disc with diffuse contrast enhancement on CT

    International Nuclear Information System (INIS)

    Goto, Jun; Shinpo, Tomoyuki; Inoue, Kiyoharu; Shigeno, Taku; Ochiai, Chikayuki

    1985-01-01

    A 48-year-old woman with the C5/6 disc herniation was reported. She had noticed vague pains in the left shoulder a half year earlier. Neurological examination showed left lower cervical radicular pains and incomplete Brown-Sequard syndrome of the same side. The disc herniation was diagnosed by myelography and discography. On the CT examination, surprisingly, the prolapsed disc was homogenously enhanced after the administration of intravenous contrast medium. The vertebral angiography showed increased vascularity behind the C5/6 intervertebral space. At operation, a prolapsed nucleus pulposus with proliferated connective tissue was found and curetted. The etiology of contrast enhancement was discussed. (author)

  11. Osteoblastic Metastases Mimickers on Contrast Enhanced CT

    Directory of Open Access Journals (Sweden)

    Fahad Al-Lhedan

    2017-01-01

    Full Text Available Secondary osseous involvement in lymphoma is more common compared to primary bone lymphoma. The finding of osseous lesion can be incidentally discovered during the course of the disease. However, osseous metastases are infrequently silent. Detection of osseous metastases is crucial for accurate staging and optimal treatment planning of lymphoma. The aim of imaging is to identify the presence and extent of osseous disease and to assess for possible complications such as pathological fracture of the load-bearing bones and cord compression if the lesion is spinal. We are presenting two patients with treated lymphoma who were in complete remission. On routine follow-up contrast enhanced CT, there were new osteoblastic lesions in the spine worrisome for metastases. Additional studies were performed for further evaluation of both of them which did not demonstrate any corresponding suspicious osseous lesion. The patients have a prior history of chronic venous occlusive thrombosis that resulted in collaterals formation. Contrast enhancement of the vertebral body marrow secondary to collaterals formation and venous flow through the vertebral venous plexus can mimic the appearance of spinal osteoblastic metastases.

  12. Pulling Helices inside Bacteria: Imperfect Helices and Rings

    Science.gov (United States)

    Allard, Jun F.; Rutenberg, Andrew D.

    2009-04-01

    We study steady-state configurations of intrinsically-straight elastic filaments constrained within rod-shaped bacteria that have applied forces distributed along their length. Perfect steady-state helices result from axial or azimuthal forces applied at filament ends, however azimuthal forces are required for the small pitches observed for MreB filaments within bacteria. Helix-like configurations can result from distributed forces, including coexistence between rings and imperfect helices. Levels of expression and/or bundling of the polymeric protein could mediate this coexistence.

  13. Multi-organ segmentation from multi-phase abdominal CT via 4D graphs using enhancement, shape and location optimization.

    Science.gov (United States)

    Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M

    2010-01-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.

  14. SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, W; Xue, M; Patel, K; Regine, W; Wang, J; D’Souza, W; Lu, W [University of Maryland School of Medicine, Baltimore, MD (United States); Kang, M [University of Maryland School of Medicine, Baltimore, MD (United States); Yeungnam University Medical Center, Daegu, Daegu (Korea, Republic of); Klahr, P [Philips Healthcare, Highland Heights, OH (United States)

    2015-06-15

    Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

  15. Low-dose helical computed tomography (CT) in the perioperative workup of adolescent idiopathic scoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Abul-Kasim, Kasim; Overgaard, Angelica; Maly, Pavel [Malmoe University Hospital, Department of Radiology, Section of Neuroradiology, University of Lund, Malmoe (Sweden); Ohlin, Acke [Malmoe University Hospital, Department of Orthopaedic Surgery, University of Lund, Malmoe (Sweden); Gunnarsson, Mikael [Malmoe University Hospital, Department of Radiation Physics, University of Lund, Malmoe (Sweden); Sundgren, Pia C. [University of Michigan Health Systems, Department of Radiology, Division of Neuroradiology, Ann Arbor (United States)

    2009-03-15

    The study aims were to estimate the radiation dose in patients examined with low dose spine CT and to compare it with that received by patients undergoing standard CT for trauma of the same region, as well as to evaluate the impact of dose reduction on image quality. Radiation doses in 113 consecutive low dose spine CTs were compared with those in 127 CTs for trauma. The inter- and intraobserver agreement in measurements of pedicular width, and vertebral rotation, measurements of signal-to-noise ratio and assessment of hardware status were the indicators in the evaluation of image quality. The effective dose of the low dose spine CT (0.37 mSv) was 20 times lower than that of a standard CT for trauma (13.09 mSv). This dose reduction conveyed no impact on image quality. This low dose spine CT protocol allows detailed evaluation that is necessary for preoperative planning and postoperative evaluation. (orig.)

  16. Prognostic criteria in acute pancreatitis: importance of assessment of pancreatic necrosis by contrast-enhanced CT

    International Nuclear Information System (INIS)

    Echevarria, F.; Martinez, B.; Lopez, F.; Vuelta, R.V.

    1997-01-01

    To compare the value of the clinical criteria of Ranson, the classical tomographic criteria of Balthzar and the severity of illness index according to CT in predicting the development of complications of acute pancreatitis. A retrospective study was performed in 100 patients with clinical and analytical evidence of acute pancreatitis. All patients were assessed according to Ranson score at admission and 48 hours later, and contrast-enhanced abdominal CT was carried out. The tomographic images were analyzed on the basis of the classical criteria of Balthazar and the new CT severity of illness index, which includes the assessment of pancreatic necrosis, identified as the areas of the pancreas that are not enhanced by the administration of the contrast material. These three criteria were then correlated with onset of medical and surgical implications. Our findings show that, of the three criteria analyzed, the CT severity of illness index presents the greatest specificity, sensitivity and positive and negative predictive values in the prediction of complications of acute pancreatitis. We conclude that the inclusion of pancreatic necrosis in the tomographic study improves the early assessment of the prognosis of acute pancreatitis. (Author) 20 refs

  17. Kinetic simulations of neoclassical and anomalous transport processes in helical systems

    International Nuclear Information System (INIS)

    Sugama, Hideo; Watanabe, Tomohiko; Nunami, Masanori; Satake, Shinsuke; Matsuoka, Seikichi; Tanaka, Kenji

    2012-01-01

    Drift kinetic and gyrokinetic theories and simulations are powerful means for quantitative predictions of neoclassical and anomalous transport fluxes in helical systems such as the Large Helical Device (LHD). The δf Monte Carlo particle simulation code, FORTEC-3D, is used to predict radial profiles of the neoclassical particle and heat transport fluxes and the radial electric field in helical systems. The radial electric field profiles in the LHD plasmas are calculated from the ambipolarity condition for the neoclassical particle fluxes obtained by the global simulations using the FORTEC-3D code, in which effects of ion or electron finite orbit widths are included. Gyrokinetic Vlasov simulations using the GKV code verify the theoretical prediction that the neoclassical optimization of helical magnetic configuration enhances the zonal flow generation which leads to the reduction of the turbulent heat diffusivity χ i due to the ion temperature gradient (ITG) turbulence. Comparisons between results for the high ion temperature LHD experiment and the gyrokinetic simulations using the GKV-X code show that the χ i profile and the poloidal wave number spectrum of the density fluctuation obtained from the simulations are in reasonable agreements with the experimental results. It is predicted theoretically and confirmed by the linear GKV simulations that the E × B rotation due to the background radial electric field E r can enhance the zonal-flow response to a given source. Thus, in helical systems, the turbulent transport is linked to the neoclassical transport through E r which is determined from the ambipolar condition for neoclassical particle fluxes and influences the zonal flow generation leading to reduction of the turbulent transport. In order to investigate the E r effect on the regulation of the turbulent transport by the zonal flow generation, the flux-tube bundle model is proposed as a new method for multiscale gyrokinetic simulations. (author)

  18. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko, E-mail: fukukura@m.kufm.kagoshima-u.ac.jp [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Takumi, Koji [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Higashi, Michiyo [Department of Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Shinchi, Hiroyuki [Department of Surgical Oncology and Digestive Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan)

    2014-04-15

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival.

  19. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukukura, Yoshihiko; Takumi, Koji; Higashi, Michiyo; Shinchi, Hiroyuki; Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro

    2014-01-01

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival

  20. Utility of the three-dimensional reconstruction by means of helical scanography in the study of stringed instruments

    International Nuclear Information System (INIS)

    Morillo Zarate, Anibal Jose; Uriza Carrasco, Luis Felipe

    1998-01-01

    The evaluation of stringed instruments with axial computerized tomography (CT) sections has been described as a reliable method for the study of its internal components and for the detection of damaged instruments. We present the application of helical CT with thin sections and 3-D reconstructions in a series of violins, for an anatomical study of the instrument. The 3-D images offer complementary information and permit a better evaluation of the internal structure of the violin that can be useful for the understanding of the secrets of its construction and for the diagnosis of structural lesions that can affect its acoustic performance