WorldWideScience

Sample records for enhanced chemiluminescence immunosensor

  1. An automatic enzyme immunoassay based on a chemiluminescent lateral flow immunosensor.

    Science.gov (United States)

    Joung, Hyou-Arm; Oh, Young Kyoung; Kim, Min-Gon

    2014-03-15

    Microfluidic integrated enzyme immunosorbent assay (EIA) sensors are efficient systems for point-of-care testing (POCT). However, such systems are not only relatively expensive but also require a complicated manufacturing process. Therefore, additional fluidic control systems are required for the implementation of EIAs in a lateral flow immunosensor (LFI) strip sensor. In this study, we describe a novel LFI for EIA, the use of which does not require additional steps such as mechanical fluidic control, washing, or injecting. The key concept relies on a delayed-release effect of chemiluminescence substrates (luminol enhancer and hydrogen peroxide generator) by an asymmetric polysulfone membrane (ASPM). When the ASPM was placed between the nitrocellulose (NC) membrane and the substrate pad, substrates encapsulated in the substrate pad were released after 5.3 ± 0.3 min. Using this delayed-release effect, we designed and implemented the chemiluminescent LFI-based automatic EIA system, which sequentially performed the immunoreaction, pH change, substrate release, hydrogen peroxide generation, and chemiluminescent reaction with only 1 sample injection. In a model study, implementation of the sensor was validated by measuring the high sensitivity C-reactive protein (hs-CRP) level in human serum. © 2013 Elsevier B.V. All rights reserved.

  2. Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay

    Science.gov (United States)

    Shi, Jing; Xu, Mingxia; Tang, Qinghui; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-02-01

    A novel flow injection chemiluminescence immunoassay for simple, sensitive and low-cost detection of diclofenac was established based on specific binding of antigen and antibody. Carboxylic resin beads used as solid phase carrier materials provided good biocompatibility and large surface-to-volume ratio for modifying more coating antigen. There was a competitive process between the diclofenac in solution and the immobilized coating antigen to react with the limited binding sites of the polyclonal antibody to form the immunocomplex. The second antibody labelled with horseradish peroxidase was introduced into the immunosensor and trapped by captured polyclonal antibody against diclofenac, which could effectively amplify chemiluminescence signals of luminol-PIP-H2O2. Under optimal conditions, the diclofenac could be detected quantitatively. The chemiluminescence intensity decreased linearly with the logarithm of the diclofenac concentration in the range of 0.1-100 ng mL- 1 with a detection limit of 0.05 ng mL- 1 at a signal-to-noise ratio of 3. The immunosensor exhibited high sensitivity, specificity and acceptable stability. This easy-operated and cost-effective analytical method could be valuable for the diclofenac determination in real water samples.

  3. Enhanced anodic Ru(bpy)32+ electrogenerated chemiluminescence by polyphenols

    International Nuclear Information System (INIS)

    Lei Rong; Xu Xiao; Xu Da; Zhu Gang; Li Na; Liu Huwei; Li Kean

    2008-01-01

    Anodic Ru(bpy) 3 2+ electrogenerated chemiluminescence (ECL) can be enhanced by polyphenols in alkaline solution. Spin trapping-electron spin resonance (ESR) experiments verified that reactive oxygen species (ROS) were generated during the electrolysis of Ru(bpy) 3 2+ in alkaline solution, and oxidation of quercetin enhanced Ru(bpy) 3 2+ ECL at anodic potential by producing additional ROS. This ECL enhancement can be used to analyze real sample and evaluate antioxidant activity of polyphenols

  4. Gold nanorods-enhanced rhodamine B-permanganate chemiluminescence and its analytical application.

    Science.gov (United States)

    Hassanzadeh, Javad; Amjadi, Mohammad; Manzoori, Jamshid L; Sorouraddin, Mohammad Hossein

    2013-04-15

    A novel enhanced chemiluminescence system was developed by applying gold nanorods (Au NRs) as catalysts in rhodamine B-permanganate reaction. Au NRs with three different aspect ratios were synthesized by seed mediated growth method and characterized by UV-Vis spectra and transmission electron microscopy. It was demonstrated that Au NRs have much higher catalytic effect than spherical nanoparticles on rhodamine B-permanganate chemiluminescence reaction. Among various sizes of Au NRs, those with average aspect ratio of 3.0 were found to have the most remarkable catalytic activity. As an analytical application of the new chemiluminescence system, albumin as a model protein was quantified based on its interaction with NRs. Albumin binds to Au NRs active surfaces and inhibits their catalytic action and therefore decreases the intensity of chemiluminescence. This diminution effect is linearly related to the concentration of the human and bovine serum albumin over the ranges of 0.45-90 and 0.75-123 nmol L(-1), respectively with the corresponding limits of detection of 0.18 and 0.30 nmol L(-1). The method was successfully applied to the determination of albumin in human and bovine serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. A kinetic study of the enhancement of solution chemiluminescence of glyoxylic acid oxidation by manganese species.

    Science.gov (United States)

    Otamonga, Jean-Paul; Abdel-Mageed, Amal; Agater, Irena B; Jewsbury, Roger A

    2015-08-01

    In order to study the mechanism of the enhancement of solution chemiluminescence, the kinetics of the decay of the oxidant and the chemiluminescence emission were followed for oxidations by permanganate, manganese dioxide sol and Mn(3+) (aq) of glyoxylic acid, using stopped-flow spectrophotometry. Results are reported for the glyoxylic acid oxidized under pseudo first-order conditions and in an acidic medium at 25 °C. For permanganate under these conditions, the decay is sigmoidal, consistent with autocatalysis, and for manganese dioxide sol and Mn(3+) it is pseudo first order. The effects of the presence of aqueous formaldehyde and Mn(2+) were observed and a fit to a simple mechanism is discussed. It is concluded that chemiluminescent enhancement in these systems is best explained by reaction kinetics. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Study on Enhancement Principle and Stabilization for the Luminol-H2O2-HRP Chemiluminescence System.

    Directory of Open Access Journals (Sweden)

    Lihua Yang

    Full Text Available A luminol-H2O2-HRP chemiluminescence system with high relative luminescent intensity (RLU and long stabilization time was investigated. First, the comparative study on the enhancement effect of ten compounds as enhancers to the luminol-H2O2-HRP chemiluminescence system was carried out, and the results showed that 4-(imidazol-1-ylphenol (4-IMP, 4-iodophenol (4-IOP, 4-bromophenol (4-BOP and 4-hydroxy-4'-iodobiphenyl (HIOP had the best performance. Based on the experiment, the four enhancers were dissolved in acetone, acetonitrile, methanol, and dimethylformamide (DMF with various concentrations, the results indicated that 4-IMP, 4-IOP, 4-BOP and HIOP dissolved in DMF with the concentrations of 0.2%, 3.2%, 1.6% and 3.2% could get the highest RLU values. Subsequently, the influences of pH, ionic strength, HRP, 4-IMP, 4-IOP, 4-BOP, HIOP, H2O2 and luminol on the stabilization of the luminol-H2O2-HRP chemiluminescence system were studied, and we found that pH value, ionic strength, 4-IMP, 4-IOP, 4-BOP, HIOP, H2O2 and luminol have little influence on luminescent stabilization, while HRP has a great influence. In different ranges of HRP concentration, different enhancers should be selected. When the concentration is within the range of 0~6 ng/mL, 4-IMP should be selected. When the concentration of HRP ranges from 6 to 25 ng/mL, 4-IOP was the best choice. And when the concentration is within the range of 25~80 ng/mL, HIOP should be selected as the enhancer. Finally, the three well-performing chemiluminescent enhanced solutions (CESs have been further optimized according to the three enhancers (4-IMP, 4-IOP and HIOP in their utilized HRP concentration ranges.

  7. Ultrasensitive interdigitated capacitance immunosensor using gold nanoparticles

    Science.gov (United States)

    Alizadeh Zeinabad, Hojjat; Ghourchian, Hedayatollah; Falahati, Mojtaba; Fathipour, Morteza; Azizi, Marzieh; Boutorabi, Seyed Mehdi

    2018-06-01

    Immunosensors based on interdigitated electrodes (IDEs), have recently demonstrated significant improvements in the sensitivity of capacitance detection. Herein, a novel type of highly sensitive, compact and portable immunosensor based on a gold interdigital capacitor has been designed and developed for the rapid detection of hepatitis B surface antigen (HBsAg). To improve the efficiency of antibody immobilization and time-saving, a self-assembled monolayer (SAM) of 2-mercaptoethylamine film was coated on IDEs. Afterwards, carboxyl groups on primary antibodies were activated through 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and were immobilized on amino-terminated SAM for better control of the oriented immobilization of antibodies on gold IDEs. In addition, gold nanoparticles conjugated with a secondary antibody were used to enhance the sensitivity. Under optimal conditions, the immunosensor exhibited the sensitivity of 0.22 nF.pg ml–1, the linear range from 5 pg ml‑1 to 1 ng ml–1 and the detection limit of 1.34 pg ml‑1, at a signal-to-noise ratio of 3.

  8. Enhancing and inhibiting effects of aromatic compounds on luminol-dimethylsulfoxide-OH(-) chemiluminescence and determination of intermediates in oxidative hair dyes by HPLC with chemiluminescence detection.

    Science.gov (United States)

    Zhou, Jian; Xu, Hong; Wan, Guo-Hui; Duan, Chun-Feng; Cui, Hua

    2004-10-08

    The effect of 36 aromatic compounds on the luminol-dimethylsulfoxide-OH(-) chemiluminescence (CL) was systematically studied. It was found that dihydroxybenzenes, and ortho- and para-substituted aminophenols and phenylenediamines inhibited the CL and phenols with three or more than three hydroxyls except phloroglucin tended to enhance the CL. The CL inhibition and enhancement was proposed to be dependent on whether superoxide anion radical (O(2)(-)) was competitively consumed by compounds in the CL system. Trihydroxybenzenes were capable of generating superoxide anion radical, leading to the CL enhancement, whereas dihydroxybenzenes were superoxide anion radical scavenger, causing the CL inhibition. Based on the inhibited CL, a novel method for the simultaneous determination of p-phenylenediamine, o-phenylenediamine, p-aminophenol, o-aminophenol, resorcinol and hydroquinone by high-performance liquid chromatography coupled with chemiluminescence detection was developed. The method has been successfully applied to determine intermediates in oxidative hair dyes and wastewater of shampooing after hair dyed.

  9. The importance of chain length for the polyphosphate enhancement of acidic potassium permanganate chemiluminescence.

    Science.gov (United States)

    Holland, Brendan J; Adcock, Jacqui L; Nesterenko, Pavel N; Peristyy, Anton; Stevenson, Paul G; Barnett, Neil W; Conlan, Xavier A; Francis, Paul S

    2014-09-09

    Sodium polyphosphate is commonly used to enhance chemiluminescence reactions with acidic potassium permanganate through a dual enhancement mechanism, but commercially available polyphosphates vary greatly in composition. We have examined the influence of polyphosphate composition and concentration on both the dual enhancement mechanism of chemiluminescence intensity and the stability of the reagent under analytically useful conditions. The average chain length (n) provides a convenient characterisation, but materials with similar values can exhibit markedly different distributions of phosphate oligomers. There is a minimum polyphosphate chain length (∼6) required for a large enhancement of the emission intensity, but no further advantage was obtained using polyphosphate materials with much longer average chain lengths. Providing there is a sufficient average chain length, the optimum concentration of polyphosphate is dependent on the analyte and in some cases, may be lower than the quantities previously used in routine detection. However, the concentration of polyphosphate should not be lowered in permanganate reagents that have been partially reduced to form high concentrations of the key manganese(III) co-reactant, as this intermediate needs to be stabilised to prevent formation of insoluble manganese(IV). Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Electrochemical immunosensors - A powerful tool for analytical applications.

    Science.gov (United States)

    Felix, Fabiana S; Angnes, Lúcio

    2018-04-15

    Immunosensors are biosensors based on interactions between an antibody and antigen on a transducer surface. Either antibody or antigen can be the species immobilized on the transducer to detect antigen or antibody, respectively. Because of the strong binding forces between these biomolecules, immunosensors present high selectivity and very high sensitivity, making them very attractive for many applications in different science fields. Electrochemical immunosensors explore measurements of an electrical signal produced on an electrochemical transductor. This signal can be voltammetric, potentiometric, conductometric or impedimetric. Immunosensors utilizing electrochemical detection have been explored in several analyses since they are specific, simple, portable, and generally disposable and can carry out in situ or automated detection. This review addresses the potential of immunosensors destined for application in food and environmental analysis, and cancer biomarker diagnosis. Emphasis is given to the approaches that have been used for construction of electrochemical immunosensors. Additionally, the fundamentals of immunosensors, technology of transducers and nanomaterials and a general overview of the possible applications of electrochemical immunosensors to the food, environmental and diseases analysis fields are described. Copyright © 2017. Published by Elsevier B.V.

  11. Smartphone-based immunosensor for CA125 detection.

    Science.gov (United States)

    Hosu, Oana; Ravalli, Andrea; Lo Piccolo, Giuseppe Mattia; Cristea, Cecilia; Sandulescu, Robert; Marrazza, Giovanna

    2017-05-01

    In this work, we report the design, the development and the characterization of the analytical performances of a colorimetric smartphone-based immunosensor for the detection of cancer antigen 125 (CA125). The immunosensor was based on a sandwich strategy in which the primary antibody was immobilized by spotting onto the 3D nitrocellulose membrane. The immunospots were subsequently incubated with CA125 solutions, followed by the affinity reaction with a secondary antibody labeled with gold nanoparticles (AuNPs). The antibody-AuNPs captured onto immunospots induced the silver deposition from a silver enhancer solution leading to the formation of gold-silver nanoparticles of different grey color spots depending on CA125 concentration. The 8 megapixels smartphone camera was integrated in a home-made dark box and used as transducer of color image acquisition and data handling. The pixel intensity of the captured images was determined by an image processing algorithm. The experimental parameters involved in each step of the immunosensor design were studied and optimized, obtaining a limit of detection of 30U/mL CA125. The selectivity of the immunoassay was proven against different concentration solutions of Vascular Endothelial Growth Factor (VEGF) antigen as an unspecific protein when a blank signal was obtained for all tested solutions. Finally, preliminary experiments in human serum samples spiked with CA125 protein were also performed. Therefore, the proposed system could represent a powerful point-of-care tool for the next generation technology for detecting and monitoring cancer biomarkers at early stages by taking advantage of nowadays gadgets with enhanced features such as smartphones. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Impedimetric biosensors and immunosensors

    International Nuclear Information System (INIS)

    Prodromidis, M.I.

    2007-01-01

    The development of methods targeting the direct monitoring of antibody-antigen interactions is particularly attractive. The design of label-free affinity-based probing concepts is the objective of much current research, at both academic and industrial levels, towards establishing alternative methods to the already existing ELISA-based immunoassays. Among these, Electrochemical Impedance Spectroscopy (EIS) represents one of the most powerful methods, due to the ability of EIS-based sensors to be more easily integrated into multi-array or microprocessor, controlled diagnostic tools. During the last decade, EIS and the concept of biochemical capacitors have been widely used for probing various types of biomolecular interactions (immunosensors, DNA hybridization, protein-protein interactions). So far, impedimetric or capacitive immunosensors have been successfully applied at the academic level. However, no prototypes have been released into the market, since major fundamental issues still exist. Even though this fact has brought the reliability of impedimetric immunosensors into question, features associated with electrochemical approaches, namely the ability to be miniaturized, remote control of implanted sensors, low cost of electrode mass production and cost effective instrumentation (without need of high-energy sources) keep impedimetric sensors particularly attractive as compared to other approaches based on microbalances, surface plasmon resonance or ellipsometry. This lecture outlines the theoretical background of impedimetric immunosensors and presents different types of impedimetric biosensors as well as the instrumental approaches that have been so far proposed in the literature. (author)

  13. Advancements and application of immunosensors in the analysis of food contaminants

    Directory of Open Access Journals (Sweden)

    MD. SHOFIUL AZAM

    2014-11-01

    Full Text Available Azam MS, Rahman MRT, Lou Z, Tang Y, Raqib SM, Jothi JS. 2014. Advancements and application of immunosensors in the analysis of food contaminants. Nusantara Bioscience 6: 186-195. Immunosensors are affinity ligand-based biosensor solid-state devices in which the immunochemical reaction is coupled to a transducer. The fundamental basis of all immunosensors is the specificity of the molecular recognition of antigens by antibodies to form a stable complex. This is similar to the immunoassay methodology. Immunosensors can be categorized based on the detection principle applied. The main developments are electrochemical, optical, and microgravimetric immunosensors. In contrast to immunoassay, modern transducer technology enables the label-free detection and quantification of the immune complex. The analysis of trace substances in environmental science, pharmaceutical and food industries is a challenge since many of these applications demand a continuous monitoring mode. The use of immunosensors in these applications is most appropriate. Food chemists should take advantage of immunosensors in food and clinical diagnostics. There are many recent developments in the immunosensor field which have potential impacts. The future role of this technique in intra-laboratory, as well as bedside testing, will become even more important as the food laboratory is faced with increasing pressure to contain costs. Objective of this paper is to give a general overview of the possible application of immunosensors to the food analysis field.

  14. A sensitive label–free amperometric immunosensor for alpha-fetoprotein based on gold nanorods with different aspect ratio

    Science.gov (United States)

    Zhou, Chunyang; Liu, Dali; Xu, Lin; Li, Qingling; Song, Jian; Xu, Sai; Xing, Ruiqing; Song, Hongwei

    2015-01-01

    A simple and accurate label–free amperometric immunosensor for α–fetoprotein (AFP) detection is developed based on gold nanorods (GNRs) with different aspect ratio and compared with gold particles (GNPs). The positively charged GNRs and GNPs due to the surface immobilized cetyltrimethyl ammonium bromide (CTAB) can adsorb the negatively charged AFP antibody (Ab) directly. The presence of the GNRs not only enhanced the immobilized amount of biomolecules, but also improved the electrochemical properties of the immunosensor. With the aid of GNRs, the electrochemical signal was greatly enhanced in comparison with GNPs. Under optimal conditions, the proposed immunosensor could detect AFP in a linear range from 0.1 to 200 ng/mL with a detection limit of 0.04 ng/mL (signal–to–noise ratio = 3), and it also possessed good reproducibility and storage stability. Moreover, the detection of AFP in five human serum samples also showed satisfactory accuracy. The proposed methodology was potentially attractive for clinical immunoassay. PMID:25909588

  15. Solid-state voltammetry-based electrochemical immunosensor for Escherichia coli using graphene oxide-Ag nanoparticle composites as labels.

    Science.gov (United States)

    Jiang, Xiaochun; Chen, Kun; Wang, Jing; Shao, Kang; Fu, Tao; Shao, Feng; Lu, Donglian; Liang, Jiangong; Foda, M Frahat; Han, Heyou

    2013-06-21

    A new electrochemical immunosensor based on solid-state voltammetry was fabricated for the detection of Escherichia coli (E. coli) by using graphene oxide-Ag nanoparticle composites (P-GO-Ag) as labels. To construct the platform, Au nanoparticles (AuNPs) were first self-assembled on an Au electrode surface through cysteamine and served as an effective matrix for antibody (Ab) attachment. Under a sandwich-type immunoassay format, the analyte and the probe (P-GO-Ag-Ab) were successively captured onto the immunosensor. Finally, the bonded AgNPs were detected through a solid-state redox process in 0.2 M of KCl solution. Combining the advantages of the high-loading capability of graphene oxide with promoted electron-transfer rate of AuNPs, this immunosensor produced a 26.92-fold signal enhancement compared with the unamplified protocol. Under the optimal conditions, the immunosensor exhibited a wide linear dependence on the logarithm of the concentration of E. coli ranging from 50 to 1.0 × 10(6) cfu mL(-1) with a detection limit of 10 cfu mL(-1). Moreover, as a practical application, the proposed immunosensor was used to monitor E. coli in lake water with satisfactory results.

  16. Enhancement effect of CdTe quantum dots-IgG bioconjugates on chemiluminescence of luminol-H2O2 system

    International Nuclear Information System (INIS)

    Kanwal, Shamsa; Traore, Zoumana; Zhao Chunfang; Su Xingguang

    2010-01-01

    In this paper we developed an entirely new and highly sensitive luminol-H 2 O 2 flow injection chemiluminescence system using the enhancement effect of CdTe quantum dots-IgG bioconjugates. Immunoglobulin G (IgG) as a kind of bio-molecule was conjugated to different sized CdTe semiconductor quantum dots (QDs). Using PL spectra and CL intensity profiles, it was found that chemiluminescence resonance energy transfer (CRET) was possibly occurring between CdTe-IgG bioconjugate and luminol. Under optimum conditions, increase of IgG concentration in CdTe-IgG bioconjugate resulted enhancing effect on CL intensity of luminol-H 2 O 2 system. Moreover quenching effects on CL intensity by addition of different proteases can construct turn off biosensor for these proteases with low detection limits and wide linear range. Furthermore, the effects of various organic and inorganic species on CdTe-IgG bioconjugates enhanced luminol-H 2 O 2 CL system were also studied in this paper.

  17. Label-free immunosensor based on Pd nanoplates for amperometric immunoassay of alpha-fetoprotein.

    Science.gov (United States)

    Wang, Huan; Li, He; Zhang, Yihe; Wei, Qin; Ma, Hongmin; Wu, Dan; Li, Yan; Zhang, Yong; Du, Bin

    2014-03-15

    In this paper, Pd nanoplates were used as a kind of electrode materials for fabrication of an electrochemical immunosensor, which was applied for detection of cancer biomarker alpha-fetoprotein (AFP). Thanks to the unique structure and properties of Pd nanoplates, the antibody of AFP (Ab) was effectively immobilized onto the surface of the Pd nanoplates modified glassy carbon electrode (GCE). Moreover, the good electrochemical properties of Pd nanoplates greatly improved the electronic transmission rate and enhanced the electrochemical signal, which led to an increase of the detection sensitivity. Based on the specific antibody-antigen interaction, a label-free immunosensor based on Pd nanoplates was developed for sensing of AFP. The current method allows us to detect AFP over a wide concentration range from 0.01 to 75.0 ng/mL with a detection limit of 4 pg/mL. The proposed immunosensor has been used to determine AFP in human serum with satisfactory results. © 2013 Elsevier B.V. All rights reserved.

  18. A photoelectrochemical immunosensor for detection of α-fetoprotein based on Au-ZnO flower-rod heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Han, Zhizhong, E-mail: zzhan@fjmu.edu.cn; Luo, Min; Chen, Li; Chen, Jinghua; Li, Chunyan, E-mail: cyli65@126.com

    2017-04-30

    Highlights: • Au NPs were deposited onto ZnO FRs by cyclic voltammetry methods. • Au NPs were used to enhance light absorption and photo-induced charge separation. • The PEC immunosensor based on Au-ZnO FRs presented a higher photocurrent. • The detection limit of this novel PEC immunosensor was 0.56 pg mL{sup −1} for AFP. - Abstract: In this work, a novel label free photoelectrochemical (PEC) immunosensor has been developed for the detection of α-fetoprotein (AFP). The immunosensor was based on Au-ZnO flower-rods (FRs) heterostructure, where Au nanoparticles (NPs) were firstly electrodeposited by cyclic voltammetry methods. Scanning electron microscopy (SEM), X-ray diffraction (XRD), Mott-Schottky plot (MS), UV–vis diffuse reflectance spectrum and fluorescence emission spectrum were used for the characterizations of Au-ZnO FRs. The results demonstrated that Au NPs not only obviously enhanced the visible light absorption of ZnO FRs due to surface plasmon resonance (SPR) but also improved the separation of photo-generated electron-hole pairs. Therefore, the photocurrent of Au-ZnO FRs was increased under simulated sunlight. The photocurrent was reduced after the specific antibody-antigen immune reaction. And the photocurrent decrement was linear with the logarithm of AFP antigen concentration in the range from 0.005 ng mL{sup −1} to 50 ng mL{sup −1} with a low detection limit of 0.56 pg mL{sup −1} (S/N = 3). The PEC immunosensor also exhibited high anti-interference property and acceptable stability. This work would provide a promising photoelectrochemical strategy for the detection of other proteins in clinical diagnosis.

  19. A photoelectrochemical immunosensor for detection of α-fetoprotein based on Au-ZnO flower-rod heterostructures

    International Nuclear Information System (INIS)

    Han, Zhizhong; Luo, Min; Chen, Li; Chen, Jinghua; Li, Chunyan

    2017-01-01

    Highlights: • Au NPs were deposited onto ZnO FRs by cyclic voltammetry methods. • Au NPs were used to enhance light absorption and photo-induced charge separation. • The PEC immunosensor based on Au-ZnO FRs presented a higher photocurrent. • The detection limit of this novel PEC immunosensor was 0.56 pg mL"−"1 for AFP. - Abstract: In this work, a novel label free photoelectrochemical (PEC) immunosensor has been developed for the detection of α-fetoprotein (AFP). The immunosensor was based on Au-ZnO flower-rods (FRs) heterostructure, where Au nanoparticles (NPs) were firstly electrodeposited by cyclic voltammetry methods. Scanning electron microscopy (SEM), X-ray diffraction (XRD), Mott-Schottky plot (MS), UV–vis diffuse reflectance spectrum and fluorescence emission spectrum were used for the characterizations of Au-ZnO FRs. The results demonstrated that Au NPs not only obviously enhanced the visible light absorption of ZnO FRs due to surface plasmon resonance (SPR) but also improved the separation of photo-generated electron-hole pairs. Therefore, the photocurrent of Au-ZnO FRs was increased under simulated sunlight. The photocurrent was reduced after the specific antibody-antigen immune reaction. And the photocurrent decrement was linear with the logarithm of AFP antigen concentration in the range from 0.005 ng mL"−"1 to 50 ng mL"−"1 with a low detection limit of 0.56 pg mL"−"1 (S/N = 3). The PEC immunosensor also exhibited high anti-interference property and acceptable stability. This work would provide a promising photoelectrochemical strategy for the detection of other proteins in clinical diagnosis.

  20. Effect of the luminol signal enhancer on the chemiluminescence intensity and kinetics

    International Nuclear Information System (INIS)

    Liang Yanli; Yu Fei; Yu Songcheng; Wu Yongjun; Zhang Hongquan; Qu Lingbo

    2012-01-01

    The novel p-phenol derivatives, 4-(1-imidazolyl)-phenol, 4-hydroxybiphenyl, 4-hydroxy-4′-iodobiphenyl were employed as highly potent signal enhancers of luminol-hydrogen peroxide (H 2 O 2 )-horseradish peroxidase (HRP) chemiluminescence (CL) system. The CL reaction conditions were optimized, and the enhancement characteristics of these enhancers were compared with each other. The employment of these molecules greatly affected important assay parameters. Practically, the use of a novel enhancer, even a slightly change of the structure (or concentration) of 4-substituted phenol derivative, could affect assay properties quite dramatically. Furthermore, the use of different enhancers in the luminol–H 2 O 2 –HRP system can affect not only the intensity of the CL signal, which is well known, but also its kinetics. The experiment data indicated that the stronger intensity was combined with a more rapid decrease of the CL signal. - Highlights: ► 4-IMP, 4-BIP and HIOP take on different signal enhancement and light kinetics. ► The employment of 4-BIP resulted in a significant improvement of the detection limit. ► The magnitude of the signal enhancement was about 2.5-fold in the same system.

  1. Automated determination of asulam by enhanced chemiluminescence using luminol/peroxidase system.

    Science.gov (United States)

    Sánchez, Francisco García; Díaz, Aurora Navas; Bracho, Visitación; Aguilar, Alfonso; Algarra, Manuel

    2009-01-01

    A flow injection system with chemiluminescence detection for the determination of asulam, enhancer of the system luminol-H(2)O(2)-horseradish peroxidase, is proposed. The method shows a moderate selectivity against other pesticides usually present in formulations of herbicides and in water. The procedure was applied to the determination of asulam in tap water samples and a recovery study was carried out in order to validate the method. The obtained results show acceptable recovery values (between 88.3 and 93.9%). The detection limit for asulam was 0.12 ng/mL. The precision of the method expressed as relative standard deviation was 1.55% (n = 8), at the 19 ng/mL level.

  2. Recent advances in immunosensor for narcotic drug detection

    Science.gov (United States)

    Gandhi, Sonu; Suman, Pankaj; Kumar, Ashok; Sharma, Prince; Capalash, Neena; Suri, C. Raman

    2015-01-01

    Introduction: Immunosensor for illicit drugs have gained immense interest and have found several applications for drug abuse monitoring. This technology has offered a low cost detection of narcotics; thereby, providing a confirmatory platform to compliment the existing analytical methods. Methods: In this minireview, we define the basic concept of transducer for immunosensor development that utilizes antibodies and low molecular mass hapten (opiate) molecules. Results: This article emphasizes on recent advances in immunoanalytical techniques for monitoring of opiate drugs. Our results demonstrate that high quality antibodies can be used for immunosensor development against target analyte with greater sensitivity, specificity and precision than other available analytical methods. Conclusion: In this review we highlight the fundamentals of different transducer technologies and its applications for immunosensor development currently being developed in our laboratory using rapid screening via immunochromatographic kit, label free optical detection via enzyme, fluorescence, gold nanoparticles and carbon nanotubes based immunosensing for sensitive and specific monitoring of opiates. PMID:26929925

  3. Comparative study of ß-glucan induced respiratory burst measured by nitroblue tetrazolium assay and real-time luminol-enhanced chemiluminescence assay in common carp (Cyprinus carpio L.)

    DEFF Research Database (Denmark)

    Jiménez, Natalia Ivonne Vera; Pietretti, D.; Wiegertjes, G. F.

    2013-01-01

    kidney cells of carp. However, whereas the NBT assay was shown to detect the production of only superoxide anions, the real-time luminol-enhanced assay could detect the production of both superoxide anions and hydrogen peroxide. Only the chemiluminescence assay could reliably record the production of ROS......-point measurement based on the intracellular reduction of nitroblue tetrazolium (NBT) and a real-time luminol-enhanced assay based on the detection of native chemiluminescence. Both assays allowed for detection of dose-dependent changes in magnitude of the respiratory burst response induced by β-glucans in head...... on a real-time scale at frequent and continual time intervals for time course experiments, providing more detailed information on the respiratory burst response. The real-time chemiluminescence assay was used to measure respiratory burst activity in macrophage and neutrophilic granulocyte-enriched head...

  4. Enhanced sensitivity of Cypridina luciferin analog (CLA) chemiluminescence for the detection of O2- with non ionic detergents

    NARCIS (Netherlands)

    Osman, A.M.; Laane, C.; Hilhorst, R.

    2000-01-01

    Superoxide anion-triggered chemiluminescence of Cypridina luciferin analogue (CLA), 2-methyl-6-phenyl-3,7-dohydroimidazo[1,2-]pyrazin-3-one, is enhanced by non-ionic detergents such as Tween 20, Triton X-100 and Tween 80. At the concentration of 0.6øv/v) the largest increase (2.7-fold) of CLA light

  5. DNA imaging and quantification using chemi-luminescent probes

    International Nuclear Information System (INIS)

    Dorner, G.; Redjdal, N.; Laniece, P.; Siebert, R.; Tricoire, H.; Valentin, L.

    1999-01-01

    During this interdisciplinary study we have developed an ultra sensitive and reliable imaging system of DNA labelled by chemiluminescence. Based on a liquid nitrogen cooled CCD, the system achieves sensitivities down to 10 fg/mm 2 labelled DNA over a surface area of 25 x 25 cm 2 with a sub-millimeter resolution. Commercially available chemi-luminescent - and enhancer molecules are compared and their reaction conditions optimized for best signal-to-noise ratios. Double labelling was performed to verify quantification with radioactive probes. (authors)

  6. Signal-enhanced electrochemiluminescence immunosensor based on synergistic catalysis of nicotinamide adenine dinucleotide hydride and silver nanoparticles.

    Science.gov (United States)

    Wang, Guangjie; Jin, Feng; Dai, Nan; Zhong, Zhaoyang; Qing, Yi; Li, Mengxia; Yuan, Ruo; Wang, Dong

    2012-03-01

    A new metal-organic nanocomposite with synergistic catalysis function was prepared and developed to construct an electrochemiluminescence (ECL) immunosensor for ultrasensitive detection of tumor biomarker CA125. Silver nanoparticles (AgNPs) and nicotinamide adenine dinucleotide hydride (NADH) that can participate and catalyze the ECL reaction of Ru(bpy)(3)(2+) were employed as the metal component and the organic component to synthesize the metal-organic nanocomposite of NADH-AgNPs (NA). The novel ECL immunosensor was assembled via Ru(bpy)(3)(2+)-doped silica nanoparticles (Ru-SiO(2)) modified electrode with the NA as immune labels. First, the chitosan-suspended Ru-SiO(2) nanoparticles were cast on the gold electrode surface to immobilize the ECL probes of Ru(bpy)(3)(2+) and link gold nanoparticles. Then, the primary antibodies were loaded onto the modified electrode via the gold sulfhydryl covalent binding. After immunobinding the analytes of antigen, NA-attached secondary antibodies could be captured as a sandwich type on the electrode. Finally, based on the circularly synergistic catalysis by the silver and NADH for the solid-phase ECL of Ru(bpy)(3)(2+), the proposed immunosensor sensed the concentration of antigen. The synergistic ECL catalysis of metal-organic nanocomposite amplified response signal and pushed the detection limit down to 0.03 U ml(-1), which initiated a new ECL labeling field and has great significance for ECL immunoassays. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. EIS immunosensor based on magnetic nanoparticles for ochratoxim A determination

    International Nuclear Information System (INIS)

    Biraruti, Irina; Tudorache, Madalina; Rotariu, Lucian; Bala, Camelia; Jaffrezic-Renault, Nicole

    2009-01-01

    Full text: Ochratoxin A (OTA) is a mycotoxin produced by Aspergillus and Penicillium fungi. It occurs in a variety of foodstuff, including cereals, coffee, wine, grape juice and fruits juice. Maximum permitted levels have been established by the EU and several countries. Currently, there are several methods available for OTA monitoring in real samples, e.g. TLC, HPLC, ELISA immunosensors. Liquid chromatography with fluorescence detection (HPLC-FLD), coupled with immunoaffinity column or solid phase extraction as pretreatment method, has been validated and adopted as official standard for OTA determination. Also, an immunosensor based on electrochemical detection has been reported for rapid analysis of OTA in food and beverages. Our work proposes the development of a new sensitive immunosensor combining the use of magnetic nanoparticles and EIS (electrochemical impedance spectroscopy) detection principle. Anti-OTA antibody immobilised on magnetic nanoparticles were deposited on the EIS electrode surface by applying a magnetic field. Then, OTA sample solutions were added in the detection cell. Quantitative determination of OTA content was performed based on EIS detection. Experimental parameters of the immunosensor were set-up at the optimum values. Based on those values, the immunosensor allows to detect OTA in the range 1-10 ng/mL. The future perspective is to validate this immunochemical method using HPLC-FLD. (authors)

  8. A disposable electrochemical immunosensor based on carbon screen-printed electrodes for the detection of prostate specific antigen.

    Science.gov (United States)

    Yan, Mei; Zang, Dejin; Ge, Shenguang; Ge, Lei; Yu, Jinghua

    2012-01-01

    A novel screen-printed electrode (SPEs) on sheets of vegetable parchment was prepared. The obtained SPEs were stable, convenient, inexpensive and suitable for large-area screen-printing. With these SPEs, we explored the fabrication of a novel, disposable and highly sensitive electro-analytical immunosensor using graphene nanosheets (GS) and horseradish peroxidase (HRP)-labeled signal antibody functionalized with gold nanoparticles (HRP-Ab(2)/Au NPs). GS was used to increase the conductivity and stability of this immunosensor due to its fast electron transportation and good biocompatibility. Au NPs could not only provide a large surface area for the immobilization of HRP-Ab(2) but also enhance the electroreduction between HRP and H(2)O(2) to amplify the electrochemical signal on the sandwich immuno-complexes modified SPEs. The proposed SPEs were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and electrochemical methods involving cyclic voltammetry (CV), and electrochemical impedence method. Using prostate specific antigen (PSA) as a model analyte, this immunosensor showed a wide linear range over 6 orders of magnitude with the minimum value down to 2 pg mL(-1). In addition, this immunosensor could avoid the need of deoxygenation for the electrochemical immunoassay. Thus, it provided a promising potential in clinical applications. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Introduction to Biosensors From Electric Circuits to Immunosensors

    CERN Document Server

    Yoon, Jeong-Yeol

    2013-01-01

    Introduction to Biosensors: From Electric Circuits to Immunosensors discusses underlying circuitry of sensors for biomedical and biological engineers as well as biomedical sensing modalities for electrical engineers while providing an applications-based approach to the study of biosensors with over 13 extensive, hands-on labs. The material is presented using a building-block approach, beginning with the fundamentals of sensor design and temperature sensors and ending with more complicated biosensors. This book also: Provides electrical engineers with the specific knowledge they need to understand biological sensing modalities Provides biomedical engineers with a solid background in circuits and systems Includes complete coverage of temperature sensors, electrochemical sensors, DNA and immunosensors, piezoelectric sensors and immunosensing in a micofluidic device Introduction to Biosensors: From Electric Circuits to Immunosensors aims to provide an interdisciplinary approach to biosensors that will be apprecia...

  10. Interferometer immunosensor based on porous silicon for determining alpha-fetoprotein

    Science.gov (United States)

    Lv, Xiaoyi; Jiang, Jing; Lv, Guodong; Mo, Jiaqing; Jia, Zhenhong

    2016-10-01

    An increased level of alpha-fetoprotein ( AFP) in the blood may be a sign of liver cancer. Porous silicon based optical microcavities structure is prepared as a label-free immunosensor platform for detecting AFP. After the antigen-antibody reaction, it is monitored that the red shift of the reflection spectrum of the immunosensor increases

  11. Screen Printed Carbon Electrode Based Electrochemical Immunosensor for the Detection of Dengue NS1 Antigen

    Directory of Open Access Journals (Sweden)

    Om Parkash

    2014-11-01

    Full Text Available An electrochemical immunosensor modified with the streptavidin/biotin system on screen printed carbon electrodes (SPCEs for the detection of the dengue NS1 antigen was developed in this study. Monoclonal anti-NS1 capture antibody was immobilized on streptavidin-modified SPCEs to increase the sensitivity of the assay. Subsequently, a direct sandwich enzyme linked immunosorbent assay (ELISA format was developed and optimized. An anti-NS1 detection antibody conjugated with horseradish peroxidase enzyme (HRP and 3,3,5,5'-tetramethybezidine dihydrochloride (TMB/H2O2 was used as an enzyme mediator. Electrochemical detection was conducted using the chronoamperometric technique, and electrochemical responses were generated at −200 mV reduction potential. The calibration curve of the immunosensor showed a linear response between 0.5 µg/mL and 2 µg/mL and a detection limit of 0.03 µg/mL. Incorporation of a streptavidin/biotin system resulted in a well-oriented antibody immobilization of the capture antibody and consequently enhanced the sensitivity of the assay. In conclusion, this immunosensor is a promising technology for the rapid and convenient detection of acute dengue infection in real serum samples.

  12. Enhanced Silver Nanoparticle Chemiluminescence Method for the Determination of Gemifloxacin Mesylate using Sequential Injection Analysis

    International Nuclear Information System (INIS)

    Alarfaj, N.A.; Aly, F.A.; Tamimi, A.A.

    2013-01-01

    A sequential injection analysis (SIA) with chemiluminescence detection has been proposed for the determination of the antibiotic gemifloxacin mesylate (GFX). The developed method is based on the enhancement effect of silver nanoparticles (Ag NPs) on the chemiluminescence (CL) signal of luminol-potassium ferricyanide reaction in alkaline medium. The introduction of gemifloxacin in this system produced a significant decrease in the CL intensity in presence of (Ag NPs). The optimum conditions for CL emission were investigated. Linear relationship between the decrease in CL intensity and concentration was obtained in the range 0.01-1000 ng mL-1, (r = 0.9997) with detection limit of 2.0 pg mL-1 and quantification limit of 0.01 pg mL-1. The relative standard deviation was 1.3 %. The proposed method was employed for the determination of gemifloxacin in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated, and no interference was found from these excipients. The obtained SIA results were statistically compared with those obtained from a reported method and did not show any significant difference at confidence level 95%. (author)

  13. Automated-immunosensor with centrifugal fluid valves for salivary cortisol measurement

    Directory of Open Access Journals (Sweden)

    Masaki Yamaguchi

    2014-08-01

    Full Text Available Point-of-care measurement of the stress hormone cortisol will greatly facilitate the timely diagnosis and management of stress-related disorders. We describe an automated salivary cortisol immunosensor, incorporating centrifugal fluid valves and a disposable disc-chip that allows for truncated reporting of cortisol levels (<15 min. The performance characteristics of the immunosensor are optimized through select blocking agents to prevent the non-specific adsorption of proteins; immunoglobulin G (IgG polymer for the pad and milk protein for the reservoirs and the flow channels. Incorporated centrifugal fluid valves allow for rapid and repeat washings to remove impurities from the saliva samples. An optical reader and laptop computer automate the immunoassay processes and provide easily accessible digital readouts of salivary cortisol measurements. Linear regression analysis of the calibration curve for the cortisol immunosensor showed 0.92 of coefficient of multiple determination, R2, and 38.7% of coefficient of variation, CV, for a range of salivary cortisol concentrations between 0.4 and 11.3 ng/mL. The receiver operating characteristic (ROC curve analysis of human saliva samples indicate potential utility for discriminating stress disorders and underscore potential application of the biosensor in stress disorders. The performance of our salivary cortisol immunosensor approaches laboratory based tests and allows noninvasive, quantitative, and automated analysis of human salivary cortisol levels with reporting times compatible with point-of-care applications. Keywords: Immunosensor, Centrifugal fluid valve, Automation, Cortisol, Saliva

  14. Immunosensors Based on Single-Walled Carbon Nanotubes (SWCNT for the Detection of Deep Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Sondes BOURIGUA

    2014-05-01

    Full Text Available Thanks to their properties, Single-Walled carbon nanotubes (SWNT open a new way to the fabrication of Immunosensors with the particularity to amplify the response signal from antibody–antigen interaction and to improve the Immunosensors characteristics. In this context, two new impedimetric immunosensors were developed by immobilizing antibody on Single-Walled carbon, the later was immobilized following two ways the first consist of immobilizing the carbon nanotubes on a polypyrrole layer by adsorption and the second consist of functionalized gold with amino thiol and then immobilizing the carbon nanotubes with covalent binding. The electrical properties and the morphology of the immunosensors have been characterized respectively by Electrochemical Impedance Spectroscopy, cyclic voltammetry and Atomic Force Spectroscopy. A low detection limit for both immunosensors was determined as 1 pg/ml and linear ranges up to 10 ng/ml with polypyrrole and up to 100 ng/ml with amino thiol were obtained. Moreover, the studied Immunosensors exhibited high sensitivity, stability and reproducibility.

  15. A novel chemiluminescence method for determination of bisphenol Abased on the carbon dot-enhanced HCO3−–H2O2 system

    International Nuclear Information System (INIS)

    Amjadi, Mohammad; Manzoori, Jamshid L.; Hallaj, Tooba

    2015-01-01

    A simple and sensitive chemiluminescence (CL) method on the basis of carbon dot (C-dot) enhanced HCO 3 − –H 2 O 2 system, is designed for the determination of bisphenol A (BPA). The very weak CL of the HCO 3 − –H 2 O 2 system is enhanced by a factor of ∼100 in the presence of C-dots. Possible mechanisms that lead to the effect were elucidated by recording fluorescence and CL spectra and studying the effect of some radical scavengers. This enhancement is inhibited by BPA in the concentration range from 1.0 to 100 µg L −1 . This is exploited for its trace determination with a detection limit (3 s) of 0.3 µg L −1 . The established method was applied to the determination of BPA in baby bottle and water samples with satisfactory results. - Highlights: • The effect of carbon dots on HCO 3 − –H 2 O 2 chemiluminescence reaction is studied. • Carbon dots greatly enhance the CL signal of this reaction (∼100 fold). • The new CL system was applied to determination of bisphenol A in real samples

  16. A self-amplified transistor immunosensor under dual gate operation: highly sensitive detection of hepatitis B surface antigen

    Science.gov (United States)

    Lee, I.-K.; Jeun, M.; Jang, H.-J.; Cho, W.-J.; Lee, K. H.

    2015-10-01

    Ion-sensitive field-effect transistors (ISFETs), although they have attracted considerable attention as effective immunosensors, have still not been adopted for practical applications owing to several problems: (1) the poor sensitivity caused by the short Debye screening length in media with high ion concentration, (2) time-consuming preconditioning processes for achieving the highly-diluted media, and (3) the low durability caused by undesirable ions such as sodium chloride in the media. Here, we propose a highly sensitive immunosensor based on a self-amplified transistor under dual gate operation (immuno-DG ISFET) for the detection of hepatitis B surface antigen. To address the challenges in current ISFET-based immunosensors, we have enhanced the sensitivity of an immunosensor by precisely tailoring the nanostructure of the transistor. In the pH sensing test, the immuno-DG ISFET showed superior sensitivity (2085.53 mV per pH) to both standard ISFET under single gate operation (58.88 mV per pH) and DG ISFET with a non-tailored transistor (381.14 mV per pH). Moreover, concerning the detection of hepatitis B surface antigens (HBsAg) using the immuno-DG ISFET, we have successfully detected trace amounts of HBsAg (22.5 fg mL-1) in a non-diluted 1× PBS medium with a high sensitivity of 690 mV. Our results demonstrate that the proposed immuno-DG ISFET can be a biosensor platform for practical use in the diagnosis of various diseases.Ion-sensitive field-effect transistors (ISFETs), although they have attracted considerable attention as effective immunosensors, have still not been adopted for practical applications owing to several problems: (1) the poor sensitivity caused by the short Debye screening length in media with high ion concentration, (2) time-consuming preconditioning processes for achieving the highly-diluted media, and (3) the low durability caused by undesirable ions such as sodium chloride in the media. Here, we propose a highly sensitive immunosensor

  17. Enhanced chemiluminescence for trazodone trace analysis based on acidic permanganate oxidation in concurrent presence of rhodamine 6G.

    Science.gov (United States)

    Fujimori, Keiichi; Sakata, Yuta; Moriuchi-Kawakami, Takayo; Shibutani, Yasuhiko

    2017-11-01

    A new sensitized chemiluminescence method by acidic permanganate oxidation was developed for the sensitive determination of trazodone. A fluorescent dye as used rhodamine 6G to increase a chemiluminescence intensity. Under optimum conditions, the liner range of the calibration curve was obtained for 1-5000 nmol/L. The limit of detection was calculated from 3σ of a blank was 0.23 nmol/L. The coexistent ions and substances had no interference with the chemiluminescence measurement. The chemiluminescence spectra were measured to elucidate a possible mechanism for the system. The present method was satisfactorily used in the determination of the drugs in pharmaceutical samples and animal serums. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Current Technologies of Electrochemical Immunosensors: Perspective on Signal Amplification

    Directory of Open Access Journals (Sweden)

    Il-Hoon Cho

    2018-01-01

    Full Text Available An electrochemical immunosensor employs antibodies as capture and detection means to produce electrical charges for the quantitative analysis of target molecules. This sensor type can be utilized as a miniaturized device for the detection of point-of-care testing (POCT. Achieving high-performance analysis regarding sensitivity has been one of the key issues with developing this type of biosensor system. Many modern nanotechnology efforts allowed for the development of innovative electrochemical biosensors with high sensitivity by employing various nanomaterials that facilitate the electron transfer and carrying capacity of signal tracers in combination with surface modification and bioconjugation techniques. In this review, we introduce novel nanomaterials (e.g., carbon nanotube, graphene, indium tin oxide, nanowire and metallic nanoparticles in order to construct a high-performance electrode. Also, we describe how to increase the number of signal tracers by employing nanomaterials as carriers and making the polymeric enzyme complex associated with redox cycling for signal amplification. The pros and cons of each method are considered throughout this review. We expect that these reviewed strategies for signal enhancement will be applied to the next versions of lateral-flow paper chromatography and microfluidic immunosensor, which are considered the most practical POCT biosensor platforms.

  19. Label-free electrochemical immunosensor based on cerium oxide nanowires for Vibrio cholerae O1 detection

    International Nuclear Information System (INIS)

    Tam, Phuong Dinh; Thang, Cao Xuan

    2016-01-01

    This paper developed a label-free immunosensor based on cerium oxide nanowire for Vibrio cholerae O1 detection application. The CeO 2 nanowires were synthesized by hydrothermal reaction. The immobilization of Anti-V. cholerae O1 onto CeO 2 nanowire-deposited sensor was performed via an amino ester, which was created by using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide, and sulfo-N-hydroxysuccinimide. The electrochemical responses of the immunosensor were studied by electrochemical impedance spectroscopy with [Fe (CN) 6 ] 3−/4− as redox probe. A linear response in electron transfer resistance for cell of V. cholerae O1 concentration was found in the range of 1.0 × 10 2 CFU/mL to 1.0 × 10 4 CFU/mL. The detection limit of the immunosensor was 1.0 × 10 2 CFU/mL. The immunosensor sensitivity was 56.82 Ω/CFU·mL −1 . Furthermore, the parameters affecting immunosensor response were also investigated, as follows: pH value, immunoreaction time, incubation temperature, and anti-V. cholerae O1 concentration. - Highlights: • A label-free immunosensor based on cerium oxide nanowire for Vibrio cholerae O1 detection application was developed. • A linear response was found in the range of 1.0 × 10 2 CFU/mL to 1.0 × 10 4 CFU/mL. • The detection limit of the immunosensor was 1.0 × 10 2 CFU/mL. • The immunosensor sensitivity was 56.82 Ω/CFU.mL −1 .

  20. Conducting polymer film-based immunosensors using carbon nanotube/antibodies doped polypyrrole

    Energy Technology Data Exchange (ETDEWEB)

    Tam, Phuong Dinh, E-mail: phuongdinhtam@gmail.com [Advanced Institute for Science and Technology (AIST), Hanoi University of Science and Technology (Viet Nam); Hieu, Nguyen Van [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology (Viet Nam)

    2011-09-15

    Carbon nanotube/polypyrrole/antibodies polymer films were synthesized successfully on microelectrodes by electrochemical deposition. Electropolymerization was performed at optimal range between -0.8 and +0.8 V at a scan rate of 50 mV s{sup -1} in an electrochemical mini-cell containing monomer pyrroles, carbon nanotubes, and goat IgGs. The conducting polymer films were characterized by Fourier transform infrared spectrometry, Raman spectra, and Field emission scanning electron microscopy. And then, it was prepared for immunosensor application to determine anti-goat IgGs. The results show that a linear range between 0.05 and 0.7 {mu}g ml{sup -1} for anti-goat IgGs detection was observed for immunosensor, a detection limit as low as 0.05 {mu}g ml{sup -1} and a response time of 1 min. The effect parameters of electropolymerization process on immunosensor response are also studied. It found that the immunosensor well active in 1.5 mg ml{sup -1} CNT concentration, 2.5 mM pyrrole, 10 {mu}g ml{sup -1} goat IgGs.

  1. An electrochemical immunosensor based on pristine graphene for rapid determination of ractopamine

    Science.gov (United States)

    Qi, Shaopeng; Zhao, Bo; Zhou, Bo; Jiang, Xiaoqing

    2017-10-01

    A new electrochemical immunosensor for fast determination of ractopamine (RAC) is fabricated based on pristine graphene (PG). The PG provides a microenvironment beneficial the immobilization of RAC, promotes the electron transfer, and raises the sensitivity of the immunosensor. The free RAC in solution can be effectively measured based on the competitive immunoreaction between RAC-antibody and RAC. The calibration graph shows linearity over the concentration ranges of 0.1-10 and 10-4000 ng mL-1. The proposed immunosensor displays a satisfactory stability, selectivity, and reproducibility and has been applied to the quantificational detection of RAC in real pork samples.

  2. Bismuth oxide nanorods based immunosensor for mycotoxin detection

    Energy Technology Data Exchange (ETDEWEB)

    Solanki, Pratima R., E-mail: pratimarsolanki@gmail.com [DST Centre for Biomolecular Electronics, CSIR-National Physical Laboratory, K.S. Krishnan Marg, New Delhi (India); Special Centre for Nano Sciences, Jawaharlal Nehru University, New Delhi 110067 (India); Singh, Jay [DST Centre for Biomolecular Electronics, CSIR-National Physical Laboratory, K.S. Krishnan Marg, New Delhi (India); Department of Applied Chemistry and Polymer Technology, Delhi Technological University, Shahbad Daulatpur, Main Bawana Road, Delhi 110042 (India); Rupavali, Bharti [DST Centre for Biomolecular Electronics, CSIR-National Physical Laboratory, K.S. Krishnan Marg, New Delhi (India); Tiwari, Sachchidanand [Special Centre for Nano Sciences, Jawaharlal Nehru University, New Delhi 110067 (India); Malhotra, Bansi D., E-mail: bansi.malhotra@gmail.com [DST Centre for Biomolecular Electronics, CSIR-National Physical Laboratory, K.S. Krishnan Marg, New Delhi (India); Department of Biotechnology, Delhi Technological University, Shahbad Daulatpur, Main Bawana Road, Delhi 110042 (India)

    2017-01-01

    We report results of the studies relating to fabrication of an efficient immunosensor based on bismuth oxide nanorods (nBi{sub 2}O{sub 3}), electrophoretically deposited onto indium-tin-oxide (ITO) coated glass substrate. This immunosensor was fabricated by immobilization of anti-aflatoxin monoclonal antibodies (Ab-AFB1) and bovine serum albumin (BSA) for aflatoxin B1 detection. The structural and morphological studies of n-Bi{sub 2}O{sub 3} have been carried out by XRD, UV–vis spectrophotometer; SEM, AFM and FTIR. It was found that the nBi{sub 2}O{sub 3} provided improved sensing characteristics to the electrode interface in terms of electroactive surface area, diffusion coefficient, charge transfer rate constant and electron transfer kinetics. The results of electrochemical response studies of this BSA/Ab-AFB1/nBi{sub 2}O{sub 3}/ITO immunosensor revealed good linearity in the range of 1–70 ng dL{sup −1} with low detection limit of 8.715 ng/dL, improved sensitivity of 1.132 μA/(ng/dL cm{sup −2}), regression coefficient R{sup 2} of 0.918 and reproducibility of > 11 times. The association constant for the BSA/Ab-AFB1/nBi{sub 2}O{sub 3}/ITO immunosensor was determined as 7.318 ng/dL. - Highlights: • Use of Bismuth oxide nanorods for aflatoxin B1 detection. • It improved the electrochemical properties. • First report on nBi{sub 2}O{sub 3} for mycotoxin detection.

  3. Impedimetric Label-Free Immunosensor on Disposable Modified Screen-Printed Electrodes for Ochratoxin A

    Directory of Open Access Journals (Sweden)

    Francesca Malvano

    2016-06-01

    Full Text Available An impedimetric label-free immunosensor on disposable screen-printed carbon electrodes (SPCE for quantitative determination of Ochratoxin A (OTA has been developed. After modification of the SPCE surface with gold nanoparticles (AuNPs, the anti-OTA was immobilized on the working electrode through a cysteamine layer. After each coating step, the modified surfaces were characterized by cyclic voltammetry (CV and electrochemical impedance spectroscopy (EIS. The capacitance was chosen as the best parameter that describes the reproducible change in electrical properties of the electrode surface at different OTA concentrations and it was used to investigate the analytical parameters of the developed immunosensor. Under optimized conditions, the immunosensor showed a linear relationship between 0.3 and 20 ng/mL with a low detection limit of 0.25 ng/mL, making it suitable to control OTA content in many common food products. Lastly, the immunosensor was used to measure OTA in red wine samples and the results were compared with those registered with a competitive ELISA kit. The immunosensor was sensitive to OTA lower than 2 μg/kg, which represents the lower acceptable limit of OTA established by European legislation for common food products.

  4. Single-walled carbon nanotube based transparent immunosensor for detection of a prostate cancer biomarker osteopontin

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Abhinav; Hong, Seongkyeol; Singh, Renu [School of Mechanical and Nuclear Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 689-798 (Korea, Republic of); Jang, Jaesung, E-mail: jjang@unist.ac.kr [School of Mechanical and Nuclear Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 689-798 (Korea, Republic of); Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 689-798 (Korea, Republic of); School of Materials Science and Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 689-798 (Korea, Republic of)

    2015-04-15

    Highlights: • A transparent CNT immunosensor is presented for detection of a prostate cancer biomarker osteopontin. • This immunosensor showed a highly linear and reproducible behavior from 1 pg mL{sup −1} to 1 μg mL{sup −1}. • The limit of detection of the immunosensor was 0.3 pg mL{sup −1}. • This immunosensor demonstrated high selectivity against bovine serum albumin and human serum. - Abstract: Osteopontin (OPN) is involved in almost all steps of cancer development, and it is being investigated as a potential biomarker for a diagnosis and prognosis of prostate cancer. Here, we report a label-free, highly sensitive and transparent immunosensor based on single-walled carbon nanotubes (SWCNTs) for detection of OPN. A high density of −COOH functionalized SWCNTs was deposited between two gold/indium tin oxide electrodes on a glass substrate by dielectrophoresis. Monoclonal antibodies specific to OPN were covalently immobilized on the SWCNTs. Relative resistance change of the immunosensors was measured as the concentration of OPN in phosphate buffer saline (PBS) and human serum was varied from 1 pg mL{sup −1} to 1 μg mL{sup −1} for different channel lengths of 2, 5, and 10 μm, showing a highly linear and reproducible behavior (R{sup 2} > 97%). These immunosensors were also specific to OPN against another test protein, bovine serum albumin, PBS and human serum, showing that a limit of detection for OPN was 0.3 pg mL{sup −1}. This highly sensitive and transparent immunosensor has a great potential as a simple point-of-care test kit for various protein biomarkers.

  5. Label-free electrochemical immunosensor based on cerium oxide nanowires for Vibrio cholerae O1 detection

    Energy Technology Data Exchange (ETDEWEB)

    Tam, Phuong Dinh, E-mail: phuongdinhtam@gmail.com; Thang, Cao Xuan, E-mail: thang.caoxuan@hust.edu.vn

    2016-01-01

    This paper developed a label-free immunosensor based on cerium oxide nanowire for Vibrio cholerae O1 detection application. The CeO{sub 2} nanowires were synthesized by hydrothermal reaction. The immobilization of Anti-V. cholerae O1 onto CeO{sub 2} nanowire-deposited sensor was performed via an amino ester, which was created by using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide, and sulfo-N-hydroxysuccinimide. The electrochemical responses of the immunosensor were studied by electrochemical impedance spectroscopy with [Fe (CN) {sub 6}] {sup 3−/4−} as redox probe. A linear response in electron transfer resistance for cell of V. cholerae O1 concentration was found in the range of 1.0 × 10{sup 2} CFU/mL to 1.0 × 10{sup 4} CFU/mL. The detection limit of the immunosensor was 1.0 × 10{sup 2} CFU/mL. The immunosensor sensitivity was 56.82 Ω/CFU·mL{sup −1}. Furthermore, the parameters affecting immunosensor response were also investigated, as follows: pH value, immunoreaction time, incubation temperature, and anti-V. cholerae O1 concentration. - Highlights: • A label-free immunosensor based on cerium oxide nanowire for Vibrio cholerae O1 detection application was developed. • A linear response was found in the range of 1.0 × 10{sup 2} CFU/mL to 1.0 × 10{sup 4} CFU/mL. • The detection limit of the immunosensor was 1.0 × 10{sup 2} CFU/mL. • The immunosensor sensitivity was 56.82 Ω/CFU.mL{sup −1}.

  6. Sensitive electrochemical immunosensor based on three-dimensional nanostructure gold electrode

    Directory of Open Access Journals (Sweden)

    Zhong G

    2015-03-01

    Full Text Available Guangxian Zhong,1,2,* Ruilong Lan,3,* Wenxin Zhang,1,4 Feihuan Fu,5 Yiming Sun,1,4 Huaping Peng,1,4 Tianbin Chen,3 Yishan Cai,6 Ailin Liu,1,4 Jianhua Lin,2 Xinhua Lin1,4 1Department of Pharmaceutical Analysis, Faculty of Pharmacy, Fujian Medical University, 2Department of Orthopaedics, 3The Centralab, First Affiliated Hospital of Fujian Medical University, 4Nano Medical Technology Research Institute, Fujian Medical University, Fuzhou, 5Department of Endocrinology, The County Hospital of Anxi, Anxi, 6Fujian International Travel Healthcare Center, Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou, People’s Republic of China *These authors contributed equally to this work Abstract: A sensitive electrochemical immunosensor was developed for detection of alpha-fetoprotein (AFP based on a three-dimensional nanostructure gold electrode using a facile, rapid, “green” square-wave oxidation-reduction cycle technique. The resulting three-dimensional gold nanocomposites were characterized by scanning electron microscopy and cyclic voltammetry. A “sandwich-type” detection strategy using an electrochemical immunosensor was employed. Under optimal conditions, a good linear relationship between the current response signal and the AFP concentrations was observed in the range of 10–50 ng/mL with a detection limit of 3 pg/mL. This new immunosensor showed a fast amperometric response and high sensitivity and selectivity. It was successfully used to determine AFP in a human serum sample with a relative standard deviation of <5% (n=5. The proposed immunosensor represents a significant step toward practical application in clinical diagnosis and monitoring of prognosis. Keywords: electrochemical immunosensors, three-dimensional nanostructure gold electrode, square-wave oxidation-reduction cycle, alpha-fetoprotein 

  7. Flow-based determination of methionine in pharmaceutical formulations exploiting TGA-capped CdTe quantum dots for enhancing the luminol-KIO{sub 4} chemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Min, E-mail: mzhou8367@sina.com [Key Laboratory of Eco-Environment-Related Polymer Materials, Ministry of Education, Key Laboratory of Polymer Materials of Gansu Province, Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); Wang, Ailian [Key Laboratory of Eco-Environment-Related Polymer Materials, Ministry of Education, Key Laboratory of Polymer Materials of Gansu Province, Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); Jiuquan Enviromental Protection Bureau, Jiuquan 735000 (China); Li, Cong; Luo, Xiaowei; Ma, Yongjun [Key Laboratory of Eco-Environment-Related Polymer Materials, Ministry of Education, Key Laboratory of Polymer Materials of Gansu Province, Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China)

    2017-03-15

    A novel flow-injection chemiluminescence method (FI-CL) was established for the determination of methionine in this paper, based on its strong enhancement on CL intensity of the luminol-KIO{sub 4} system catalyzed by thioglycolic acid-capped CdTe quantum dots in alkaline media. Under the optimized conditions, the relative CL intensity was in proportion to methionine concentration in the range from 1.0×10{sup −8} to 1.0×10{sup −5} g mL{sup −1} with a detection limit of 6.6×10{sup −9} g mL{sup −1} (3σ). The relative standard deviation (RSD) of the CL intensity for 1.0×10{sup −6} g mL{sup −1} standard methionine solution was 0.97% (n=11). The proposed method was successfully applied to determine methionine in commercial pharmaceutical formulations with recoveries between 98.0% and 101.9%. The possible CL mechanism was discussed as well. - Graphical abstract: Methionine in commercial pharmaceutical formulations was determined by flow-injection chemiluminescence and the possible chemiluminescence mechanism was discussed as well.

  8. Zinc oxide nanoparticle-enhanced ultrasensitive chemiluminescence immunoassay for the carcinoma embryonic antigen

    International Nuclear Information System (INIS)

    Pal, Souvik; Bhand, Sunil

    2015-01-01

    An ultrasensitive enzyme-linked immunosorbent assay (ELISA) is reported for the determination of carcinoma embryonic antigen (CEA) in human serum. It was realized using a microplate reader using a 384-well plate. Monoclonal antibody (Ab) against CEA (1° Ab) acting as the capture probe was immobilized on zinc oxide nanoparticles (ZnO-NPs) in the form of self-assembled monolayers (SAMs). CEA captured by 1° Ab was quantified using a sandwich ELISA wherein a polyclonal second antibody against CEA (2° Ab) was used for detection and quantified using an HRP-labeled secondary antibody (3° Ab). The ZnO-NPs-CEA capture probe was deposited on the bottom of the wells in order to enhance capture of CEA. A 3-fold enhancement in the chemiluminescence (CL) signal of luminol is found (compared to a conventional ELISA). CEA can be quantified by this method in concentrations as low as 1 pg · mL −1 . The upper limit of detection is 20 ng · mL −1 . The use of ZnO-NPs also imparts improved thermal stability. When stored at 4 °C in phosphate-buffered saline of pH 7.4, the probe displays stability of up to 30 days. (author)

  9. Nanobody-Based Apolipoprotein E Immunosensor for Point-of-Care Testing.

    Science.gov (United States)

    Ren, Xiang; Yan, Junrong; Wu, Dan; Wei, Qin; Wan, Yakun

    2017-09-22

    Alzheimer's disease (AD) biomarkers can reflect the neurochemical indicators used to estimate the risk in clinical nephrology. Apolipoprotein E (ApoE) is an early biomarker for AD in clinical diagnosis. In this research, through bactrian camel immunization, lymphocyte isolation, RNA extraction, and library construction, ApoE-specific Nbs with high affinity were successfully separated from an immune phage display nanobody library. Herein, a colorimetric immunosensor was developed for the point-of-care testing of ApoE by layer-by-layer nanoassembly techniques and novel nanobodies (Nbs). Using highly oriented Nbs as the capture and detection antibodies, an on-site immunosensor was developed by detecting the mean gray value of fade color due to the glutaraldehyde@3-aminopropyltrimethoxysilane oxidation by H 2 O 2 . The detection limit of AopE is 0.42 pg/mL, and the clinical analysis achieves a good performance. The novel easily operated immunosensor may have potential application in the clinical diagnosis and real-time monitoring for AD.

  10. Rapid Detection Technology for Pesticides Residues Based on Microelectrodes Impedance Immunosensor

    Directory of Open Access Journals (Sweden)

    Wen Ping Zhao

    2014-09-01

    Full Text Available Compared with conventional methods, electrochemical immunosensors have many advantages, such as low cost, high sensitivity, and rapid detection, and has certain prospects for realizing real-time-monitoring. In this paper, a design of portable pesticide residues detection instrument was presented based on an electrochemical impedance immunosensor. Firstly, we studied on an impedance immunosensor based on interdigitated array microelectrode (IDAM coupled with magnetic nanobeads-antibody conjugates (MNAC for the pesticide detection. Magnetic nanobeads (diameter 150 nm coated with anti-carbofuran antibodies were used for further amplification of the binding reaction between antibody and hapten (carbofuran. Secondly, in order to develop a portable pesticide residue apparatus, we designed the impedance detection electric circuit. Main work included designing and constructing of the system circuit, designing and debugging of the system software and so on. Thirdly, the apparatus was used for the standard pesticides solutions testing combined with immunosensor to test the reliability and stability. The pesticide added standard recovery was more than 70 % and the impedance test error was less than 5 %. The results showed that the proposed instrument had a good consistence compared with the traditional analytical methods. Thus, it would be a promising rapid detection instrument for pesticide residues in agricultural products.

  11. Optical fiber immunosensor based on polarimetry

    NARCIS (Netherlands)

    Kooyman, R.P.H.; Heideman, Rene; Koster, R.; Greve, Jan

    1991-01-01

    The authors discuss a type of evanescent field fiber immunosensor, based upon a polarimetric detection scheme. In this method the refractive indices of the involved chemical compounds are used as reporters of the binding event; no external label molecules are required. It is demonstrated that a

  12. Nanomaterial-Based Electrochemical Immunosensors for Clinically Significant Biomarkers

    Directory of Open Access Journals (Sweden)

    Niina J. Ronkainen

    2014-06-01

    Full Text Available Nanotechnology has played a crucial role in the development of biosensors over the past decade. The development, testing, optimization, and validation of new biosensors has become a highly interdisciplinary effort involving experts in chemistry, biology, physics, engineering, and medicine. The sensitivity, the specificity and the reproducibility of biosensors have improved tremendously as a result of incorporating nanomaterials in their design. In general, nanomaterials-based electrochemical immunosensors amplify the sensitivity by facilitating greater loading of the larger sensing surface with biorecognition molecules as well as improving the electrochemical properties of the transducer. The most common types of nanomaterials and their properties will be described. In addition, the utilization of nanomaterials in immunosensors for biomarker detection will be discussed since these biosensors have enormous potential for a myriad of clinical uses. Electrochemical immunosensors provide a specific and simple analytical alternative as evidenced by their brief analysis times, inexpensive instrumentation, lower assay cost as well as good portability and amenability to miniaturization. The role nanomaterials play in biosensors, their ability to improve detection capabilities in low concentration analytes yielding clinically useful data and their impact on other biosensor performance properties will be discussed. Finally, the most common types of electroanalytical detection methods will be briefly touched upon.

  13. Electrochemical impedance spectroscopy for analytical determination of paraquat in meconium samples using an immunosensor modified with fullerene, ferrocene and ionic liquid

    Energy Technology Data Exchange (ETDEWEB)

    Sun Xiulan [State Key Laboratory of Food Science and Technology, Wuxi 214122 (China); Li Zaijun, E-mail: zaijunli@263.ne [School of Chemical and Materials Engineering, Jiangnan University, Lihu Road 1800, Wuxi 214122 (China); Cai, Yan; Wei, Zhilei [School of Chemical and Materials Engineering, Jiangnan University, Lihu Road 1800, Wuxi 214122 (China); Fang Yinjun; Ren Guoxiao; Huang Yaru [Zhejiang Zanyu Technology Limited Corporation, Hangzhou 311215 (China)

    2011-01-01

    The paper reports a highly sensitive electrochemical immunosensor for the detection of paraquat. The immunosensor bases on glassy carbon electrode modified with a composite made from fullerene, ferrocene and the ionic liquid. The components were immobilized on the electrode surface by chitosan. The antibody of paraquat was covalently conjugated to the surface which was then blocked with bovine serum albumin. Analytical characteristics of the immunosensor were investigated by electrochemical impedance spectroscopy. It offers good repeatability (RSD = 1.5%), a stability of more than 150 days, an impedimetric response to paraquat in the range from 3.89 x 10{sup -11} to 4.0 x 10{sup -8} mol L{sup -1}, and a detection limit (S/N = 3) of 9.0 x 10{sup -12} mol L{sup -1}. The effects of omitting fullerene and the ionic liquid were well tested. The results indicated that sensitivity of the immunosensor is 3.7-fold better if fullerene and ionic liquid are used. This demonstrates that fullerene facilitates electron transfer on surface of the electrode due to unique electrochemical properties, while the ionic liquid provides biocompatible microenvironment for the antibody, which results in the enhanced sensitivity and stability. Moreover, surface morphology feature and electrochemical properties of the electrode were also examined. The method was satisfactorily applied to the determination of paraquat in meconium.

  14. Chemiluminescence emission from irradiated polytetrafluoroethylene (PTFE)

    International Nuclear Information System (INIS)

    Zhong Xiaoguang; Sun Jiazhen; Yoshii, Fumio; Sasaki, Takashi; Makuuchi, Keizo

    2000-01-01

    PTFE is well known for its chemical and high temperature resistance and also for its high-energy radiation sensitivity. The present work deals with the radiation-induced emission of chemiluminescence from PTFE film, which is generally thought as a measure of radiation induced oxidation reaction in irradiated polymer. The observation that the much stronger chemiluminescence emission from PTFE than that from other polymeric system indicate the unusual high degree of radiation induced oxidation in PTFE. On the other hand the temperature and atmosphere effect during radiation on emission of chemiluminescence were also reported. (author)

  15. A novel immunosensor for Enterobacter sakazakii based on multiwalled carbon nanotube/ionic liquid/thionine modified electrode

    International Nuclear Information System (INIS)

    Zhang Xiao; Dou Wenchao; Zhan Xuejia; Zhao Guangying

    2012-01-01

    Highlights: ► Constructed a novel immunosensor using MWCNT/[BMIM]PF 6 /thionine for E. sakazakii. ► Optimum conditions for the detection of E. sakazakii were investigated. ► The properties of proposed immunosensor were studied by AFM and CVs. ► The biosensor exhibited good specificity, reproducibility, stability and accuracy. - Abstract: A novel immunosensor for Enterobacter sakazakii (E. sakazakii) based on screen-printed carbon electrode (SPCE) modified by multiwalled carbon nanotube (MWCNT), 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM]PF 6 ) and thionine (Thi) was developed for the first time. The surface morphologies of modified electrodes were characterized by means of atomic force microscope (AFM). The electrochemical performance of the immunosensor was evaluated by cyclic voltammetry. Horseradish peroxidase labeled antibody to E. sakazakii in [BMIM]PF 6 showed high activity and stability. Under optimal conditions, E. sakazakii could be detected in range of 10 3 –10 9 CFU/ml with detection limit of 7.7 × 10 1 CFU/ml. The proposed immunosensor exhibited excellent long-time storage stability and had potential use in clinical immunoassay of E. sakazakii.

  16. Applications of chemiluminescence to bacterial analysis

    Science.gov (United States)

    Searle, N. D.

    1975-01-01

    Luminol chemiluminescence method for detecting bacteria was based on microbial activation of the oxidation of the luminol monoanion by hydrogen peroxide. Elimination of the prior lysing step, previously used in the chemiluminescence technique, was shown to improve considerably the reproducibility and accuracy of the method in addition to simplifying it. An inexpensive, portable photomultiplier detector was used to measure the maximum light intensity produced when the sample is added to the reagent. Studies of cooling tower water show that the luminol chemiluminescence technique can be used to monitor changes in viable cell population both under normal conditions and during chlorine treatment. Good correlation between chemiluminescence and plate counts was also obtained in the analysis of process water used in paper mills. This method showed good potential for monitoring the viable bacteria populations in activated sludge used in waste treatment plants to digest organic matter.

  17. Temperature dependence of immunoreactions using shear horizontal surface acoustic wave immunosensors

    Science.gov (United States)

    Kogai, Takashi; Yatsuda, Hiromi; Kondoh, Jun

    2017-07-01

    In this paper, the temperature dependence of immunoreactions, which are antibody-antigen reactions, on a shear horizontal surface acoustic wave (SH-SAW) immunosensor is described. The immunosensor is based on a reflection-type delay line on a 36° Y-cut 90° X-propagation quartz substrate, where the delay line is composed of a floating electrode unidirectional transducer (FEUDT), a grating reflector, and a sensing area between them. In order to evaluate the temperature dependence of immunoreactions, human serum albumin (HSA) antigen-antibody reactions are investigated. The SH-SAW immunosensor chip is placed in a thermostatic chamber and the changes in the SH-SAW velocity resulting from the immunoreactions are measured at different temperatures. As a result, it is observed that the HSA immunoreactions are influenced by the ambient temperature and that higher temperatures provide more active reactions. In order to analyze the immunoreactions, an analytical approach using an exponential fitting method for changes in SH-SAW velocity is employed.

  18. Electrochemical Immunosensor Based on Polythionine/Gold Nanoparticles for the Determination of Aflatoxin B1

    Directory of Open Access Journals (Sweden)

    Joseph H.O. Owino

    2008-12-01

    Full Text Available An aflatoxin B1 (AFB1 electrochemical immunosensor was developed by the immobilisation of aflatoxin B1-bovine serum albumin (AFB1-BSA conjugate on a polythionine (PTH/gold nanoparticles (AuNP-modified glassy carbon electrode (GCE. The surface of the AFB1-BSA conjugate was covered with horseradish peroxidase (HRP, in order to prevent non-specific binding of the immunosensors with ions in the test solution. The AFB1 immunosensor exhibited a quasi-reversible electrochemistry as indicated by a cyclic voltammetric (CV peak separation (ΔEp value of 62 mV. The experimental procedure for the detection of AFB1 involved the setting up of a competition between free AFB1 and the immobilised AFB1-BSA conjugate for the binding sites of free anti-aflatoxin B1 (anti-AFB1 antibody. The immunosensor’s differential pulse voltammetry (DPV responses (peak currents decreased as the concentration of free AFB1 increased within a dynamic linear range (DLR of 0.6 - 2.4 ng/mL AFB1 and a limit of detection (LOD of 0.07 ng/mL AFB1. This immunosensing procedure eliminates the need for enzyme-labeled secondary antibodies normally used in conventional ELISA–based immunosensors.

  19. A graphene-based label-free voltammetric immunosensor for sensitive detection of the egg allergen ovalbumin.

    Science.gov (United States)

    Eissa, Shimaa; L'Hocine, Lamia; Siaj, Mohamed; Zourob, Mohammed

    2013-08-07

    A graphene-based label-free voltammetric immunosensor for the sensitive detection of the egg white allergen ovalbumin has been developed. Graphene-modified screen printed carbon electrodes have been covalently functionalized using electrochemical reduction of in situ generated aryl diazonium salt forming a carboxyphenyl film on the graphene surface. The blocking property of the carboxyphenyl film grafted on to the graphene electrodes using different cyclic voltammetry cycles has been characterized using differential pulse voltammetry in [Fe(CN)6](3-/4-) solution. Then, the terminal carboxylic groups on the graphene surface were activated using EDC/NHS and used to immobilize the ovalbumin antibody and construct the immunosensor. The fabrication steps of the immunosensor have also been characterized using differential pulse voltammetry. The decrease in the [Fe(CN)6](3-/4-) reduction peak current after the immunochemical reaction with ovalbumin has been used for the ovalbumin detection. The developed immunosensor has been used for ovalbumin detection in the concentration range of 1 pg mL(-1) to 0.5 μg mL(-1) with a detection limit of 0.83 pg mL(-1) in PBS buffer. The food matrix effect studied with ovalbumin spiked cake extract showed a good percentage of recovery, indicating the possible applicability of the developed immunosensor in real food samples.

  20. 3D label-free prostate specific antigen (PSA) immunosensor based on graphene-gold composites.

    Science.gov (United States)

    Jang, Hee Dong; Kim, Sun Kyung; Chang, Hankwon; Choi, Jeong-Woo

    2015-01-15

    Highly sensitive and label-free detection of the prostate specific antigen (PSA) remains a challenge in the diagnosis of prostate cancer. Here, a novel three-dimensional (3D) electrochemical immunosensor capable of sensitive and label-free detection of PSA is reported. This unique immunosensor is equipped with a highly conductive graphene (GR)-based gold (Au) composite modified electrode. The GR-based Au composite is prepared using aerosol spray pyrolysis and the morphology of the composite is the shape of a crumpled GR ball decorated with Au nanoparticles. Unlike the previous research, this novel 3D immunosensor functions very well over a broad linear range of 0-10 ng/mL with a low detection limit of 0.59 ng/mL; furthermore, it exhibits a significantly increased electron transfer and high sensitivity toward PSA. The highest rate of current change with respect to the PSA concentration is 5 μA/(ng/mL). Satisfactory selectivity, reproducibility, and stability of the 3D immunosensor are also exhibited. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Sensitive electrochemical immunosensor for α-fetoprotein based on graphene/SnO2/Au nanocomposite.

    Science.gov (United States)

    Liu, Junfeng; Lin, Guanhua; Xiao, Can; Xue, Ying; Yang, Ankang; Ren, Hongxuan; Lu, Wensheng; Zhao, Hong; Li, Xiangjun; Yuan, Zhuobin

    2015-09-15

    A label-free electrochemical immunosensor for sensitive detection of α-fetoprotein (AFP) was developed based on graphene/SnO2/Au nanocomposite. The graphene/SnO2/Au nanocomposite modified glassy carbon electrode was used to immobilize α-fetoprotein antibody (anti-AFP) and to construct the immunosensor. Results demonstrated that the peak currents of [Ru(NH3)6](3+) decreased due to the interaction between antibody and antigen on the modified electrode. Thus, a label-free immunosensor for the detection of AFP was realized by monitoring the peak current change of [Ru(NH3)6](3+). The factors influencing the performance of the immunosensor were investigated in details. Under optimal conditions, the peak currents obtained by DPV decreased linearly with the increasing AFP concentrations in the range from 0.02 to 50 ng mL(-1) with a linear coefficient of 0.9959. This electrochemical immunoassay has a low detection limit of 0.01 ng mL(-1) (S/N=3) and was successfully applied to the determination of AFP in serum samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. An Amperometric Immunosensor Based on Graphene Composite Film and Protein a for Chlorpyrifos Detection

    Directory of Open Access Journals (Sweden)

    Xiangyou Wang

    2014-09-01

    Full Text Available In this paper, an immunosensor was designed for chlorpyrifos detection, which was based on graphene-multi-walled carbon nanotubes-gold nanoparticle-chitosan (GR-MWCNTs-AuNPs- CHIT nanocomposite film. Protein A (SPA can combine with gold nanoparticles, which made anti- chlorpyrifos antibody immobilized orientedly, eventually the modified immunosensor was developed for the detection of chlorpyrifos residues. Under the optimized conditions, a regression equation: y=9.5676 lgC (ng/mL +18.164 (R2=0.9976 was obtained with a detection limit as low as 0.037 ng/mL. The proposed chlorpyrifos immunosensor exhibited high reproducibility, stability, and good selectivity and regeneration, it has the potential of real sample detection.

  3. Investigation of RuBPS-Ce(IV) chemiluminescence reaction and its application in determination of two diuretics

    Energy Technology Data Exchange (ETDEWEB)

    Xi Juan [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Ji Xinghu [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Zhang Shaohong [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Xiang Fan Vocational and Technical College, Xiangfan 441021 (China); Ai Xinping [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); He Zhike [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)]. E-mail: zhkhe@whu.edu.cn

    2005-06-13

    The chemiluminescence mechanism of tris-(4,7-diphenyl-1,10-phenanthrolinedisulfonic acid)ruthenium(II) (RuBPS)-Ce(IV) system and the effects of two diuretics, hydrochlorothiazide and furosemide, on its chemiluminescence intensity were investigated in detail. It was found that each of the two diuretics could enhance the chemiluminescence emission intensity of RuBPS-Ce(IV) system, based on which, they were sensitively detected by chemiluminescence analysis, respectively. Under the optimum experimental conditions, the linear range and detection limit of hydrochlorothiazide were 2.5 x 10{sup -3} to 6.0 x 10{sup -1} {mu}g ml{sup -1} and 1.0 x 10{sup -3} {mu}g ml{sup -1}, respectively; those of furosemide were 1.0 x 10{sup -2} to 4.0 {mu}g ml{sup -1} and 8.8 x 10{sup -3} {mu}g ml{sup -1}, respectively. The proposed method has been applied to analyze the pharmaceuticals with satisfied results.

  4. 40 CFR 1065.270 - Chemiluminescent detector.

    Science.gov (United States)

    2010-07-01

    ... Chemiluminescent detector. (a) Application. You may use a chemiluminescent detector (CLD) to measure NOX concentration in raw or diluted exhaust for batch or continuous sampling. We generally accept a CLD for NOX...) Component requirements. We recommend that you use a CLD that meets the specifications in Table 1 of § 1065...

  5. A sensitive label-free electrochemical immunosensor for detection of cytokeratin 19 fragment antigen 21-1 based on 3D graphene with gold nanopaticle modified electrode.

    Science.gov (United States)

    Zeng, Yan; Bao, Jing; Zhao, Yanan; Huo, Danqun; Chen, Mei; Yang, Mei; Fa, Huanbao; Hou, Changjun

    2018-02-01

    Previous studies have confirmed that cytokeratin 19 fragment antigen 21-1 (CYFRA 21-1) serves as a powerful biomarker in non-small cell lung cancer (NSCLC). Herein, we report for the first time a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker CYFRA21-1. In this work, three-dimensional graphene @ gold nanoparticles (3D-G@Au) nanocomposite was modified on the glassy carbon electrode (GCE) surface to enhance the conductivity of immunosensor. The anti-CYFRA21-1 captured and fixed on the modified GCE through the cross-linking of chitosan (CS), glutaraldehyde (GA) and anti-CYFRA21-1. The differential pulse voltammetry (DPV) peak current change due to the specific interaction between anti-CYFRA21-1 and CYFRA21-1 on the modified electrode surface was utilized to detect CYFRA21-1. Under optimized conditions, the proposed electrochemical immunosensor was employed to detect CYFRA21-1 and exhibited a wide linear range of 0.25-800ngmL -1 and low detection limit of 100pgmL -1 (S/N = 3). Moreover, the recovery rates of serum samples were in the range from 95.2% to 108.7% and the developed immunosensor also shows a good correlation (less than 6.6%) with enzyme-linked immunosorbent assay (ELISA) in the detection of clinical serum samples. Therefore, it is expected that the proposed immunosensor based on a 3D-G@Au has great potential in clinical medical diagnosis of CYFRA21-1. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. A SPR-based immunosensor for the detection of isoproturon.

    Science.gov (United States)

    Gouzy, Marie-Françoise; Kess, Melanie; Krämer, Petra M

    2009-02-15

    The proof of principle of a reusable surface plasmon resonance (SPR)-based immunosensor for the monitoring of isoproturon (IPU), a selective and systemic herbicide, is presented. The detecting rat monoclonal anti-isoproturon antibody (mAb IOC 7E1) was reversibly immobilized through the use of a capture mouse anti-rat (kappa-chain) monoclonal antibody (mAb TIB 172), which was covalently immobilized on the sensor chip surface. Such strategy features a controlled binding of the captured detecting antibody as well as facilitates the surface regeneration. The capture of the anti-IPU mAb by the antibody (TIB 172) coated sensor surface could be carried out up to 120 times (immobilization/regeneration cycles) without any evidence of activity loss. With a high test midpoint and a low associated SPR signal, the direct detection format was shown to be unsuitable for the routine analysis of isoproturon. However, the limit of detection (LOD) could be easily enhanced by using a strategy based on a surface competition assay, which improved all immunosensor parameters. Moreover, the sensitivity and working range of the indirect format were found to be dependent on the surface density of the anti-IPU mAb IOC 7E1. As expected for competitive formats, the lowest surface coverage (0.5 ng/mm(2)) allowed a lower detection of the herbicide isoproturon with a calculated LOD of 0.1 microg/l, an IC(50) (50% inhibition) of 5.3+/-0.6 microg/l, and a working range (20-80% inhibition) of 1.3-16.3 microg/l.

  7. Impedimetric immunosensor for detection of cardiovascular disorder risk biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Raju, E-mail: khan.raju@gmail.com [Analytical Chemistry Division, CSIR-North East Institute of Science & Technology, Academy of Scientific and Innovative Research, Jorhat 785006, Assam (India); Pal, Mintu [Biotechnology Division, CSIR-North East Institute of Science & Technology, Academy of Scientific and Innovative Research, Jorhat 785006, Assam (India); Kuzikov, Alexey V.; Bulko, Tanya; Suprun, Elena V.; Shumyantseva, Victoria V. [Institute of Biomedical Chemistry, Pogodinskaya Street, 10, Moscow 119121 (Russian Federation)

    2016-11-01

    We report the construction and characterization of a novel, level free impedimetric immunosensor for rapid, sensitive and selective detection of myoglobin (Mb). Monoclonal anti-myoglobin (anti-Mb-IgG) antibody was immobilized on screen-printed multiwalled carbon nanotubes electrode for signal amplification without the need of natural enzymes. The fabrication of resulting immunosensor was extensively characterized by using scanning electron microscopy (SEM), fourier transform infrared (FT-IR) spectroscopy, cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Electrochemical impedance spectroscopy (EIS) technique offered a linear detection range (0.1–90 ng mL{sup −1}) of myoglobin with sensitivity of 0.74 kΩ ng mL{sup −1} (correlation coefficient, R{sup 2} = 0.97) and detection limit of 0.08 ng mL{sup −1} (S/N = 3). The mean percentage recovery of Mb in serum samples using this working biosensor is 97.33%. Furthermore, the proposed strategy can be a promising alternative for detection of Mb related cardiovascular disorders. - Highlights: • Fabrication of impedimetric immunosensor based on SPEs-MWCNTs for the detection of myoglobin. • Immobilization of monoclonal myoglobin antibody on the electrode surface was confirmed by EIS and SEM. • The sensitivity of myoglobin is 0.74 kΩ ngmL{sup -1} with detection limit of 0.08 ngmL{sup -1}.

  8. Enzyme-free electrochemical immunosensor configured with Au-Pd nanocrystals and N-doped graphene sheets for sensitive detection of AFP.

    Science.gov (United States)

    Zhao, Lifang; Li, Songjun; He, Jing; Tian, Guihong; Wei, Qin; Li, He

    2013-11-15

    A novel electrochemical immunosensor capable of enzyme-free detection of alpha fetoprotein (AFP) is reported. This immunosensor was fabricated in a sandwich-like format where catalytic Au-Pd nanocrystals and highly conductive N-doped graphene sheets were incorporated. The significant catalysis by Au-Pd nanocrystals toward hydrogen peroxide, along with the increased electron transfer by graphene sheets, caused signal generation and increased sensitivity, which enables the enzyme-free detection of AFP. With a low detection limit at 0.005 ng mL(-1), this novel immunosensor worked well over the broad linear range of 0.05-30 ng mL(-1). Unlike previously reported enzyme-based electrochemical immunosensors, which often involve the complicated steps for enzyme loading and necessary treatments to keep the activity of enzyme, this novel immunosensor is simple in nature and employed catalytic Au-Pd nanoparticles and highly conductive graphene, which thus enables reliable and sensitive detection for clinic usage. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Copper-doped titanium dioxide nanoparticles as dual-functional labels for fabrication of electrochemical immunosensors.

    Science.gov (United States)

    Zhang, Sen; Ma, Hongmin; Yan, Liangguo; Cao, Wei; Yan, Tao; Wei, Qin; Du, Bin

    2014-09-15

    Constructions of versatile electroactive labels are key issues in the development of electrochemical immunosensors. In this study, copper-doped titanium dioxide nanoparticle (Cu@TiO2) was synthesized and used as labels for fabrication of sandwich-type electrochemical immunosensors on glassy carbon electrode (GCE). Due to the presence of copper ions, Cu@TiO2 shows a strong response current when coupled to an electrode. The prepared nanocomposite also shows high electrocatalytic activity towards reduction of hydrogen peroxide (H2O2). The dual functionality of Cu@TiO2 enables the fabrication of immunosensor using different detection modes, that is, square wave voltammetry (SWV) or chronoamperometry (CA). While Cu@TiO2 was used as labels of secondary antibodies (Ab2), carboxyl functionalized graphene oxide (CFGO) was used as electrode materials to immobilize primary antibodies (Ab1). Using human immunoglobulin G (IgG) as a model analyte, the immunosensor shows high sensitivity, acceptable stability and good reproducibility for both detection modes. Under optimal conditions, a linear range from 0.1 pg/mL to 100 ng/mL with a detection limit of 0.052 pg/mL was obtained for SWV analysis. For CA analysis, a wider linear range from 0.01 pg/mL to 100 ng/mL and a lower detection limit of 0.0043 pg/mL were obtained. The proposed metal ion-based enzyme-free and noble metal-free immunosensor may have promising applications in clinical diagnoses and many other fields. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs).

    Science.gov (United States)

    Tuteja, Satish K; Chen, Rui; Kukkar, Manil; Song, Chung Kil; Mutreja, Ruchi; Singh, Suman; Paul, Ashok K; Lee, Haiwon; Kim, Ki-Hyun; Deep, Akash; Suri, C Raman

    2016-12-15

    A label-free immunosensor based on electrochemical impedance spectroscopy has been developed for the sensitive detection of a cardiac biomarker myoglobin (cMyo). Hydrothermally synthesized graphene quantum dots (GQDs) have been used as an immobilized template on screen printed electrodes for the construction of an impedimetric sensor platform. The GQDs-modified electrode was conjugated with highly specific anti-myoglobin antibodies to develop the desired immunosensor. The values of charge transfer resistance (Rct) were monitored as a function of varying antigen concentration. The Rct value of the immunosensor showed a linear increase (from 0.20 to 0.31kΩ) in the range of 0.01-100ng/mL cMyo. The specific detection of cMyo was also made in the presence of other competing proteins. The limit of detection for the proposed immunosensor was estimated as 0.01ng/mL which is comparable to the standard ELISA techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. DNA imaging and quantification using chemi-luminescent probes; Imagerie et quantification d`ADN par chimiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Dorner, G; Redjdal, N; Laniece, P; Siebert, R; Tricoire, H; Valentin, L [Groupe I.P.B., Experimental Research Division, Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1999-11-01

    During this interdisciplinary study we have developed an ultra sensitive and reliable imaging system of DNA labelled by chemiluminescence. Based on a liquid nitrogen cooled CCD, the system achieves sensitivities down to 10 fg/mm{sup 2} labelled DNA over a surface area of 25 x 25 cm{sup 2} with a sub-millimeter resolution. Commercially available chemi-luminescent - and enhancer molecules are compared and their reaction conditions optimized for best signal-to-noise ratios. Double labelling was performed to verify quantification with radioactive probes. (authors) 1 fig.

  12. Rational design for enhancing inflammation-responsive in vivo chemiluminescence via nanophotonic energy relay to near-infrared AIE-active conjugated polymer.

    Science.gov (United States)

    Seo, Young Hun; Singh, Ajay; Cho, Hong-Jun; Kim, Youngsun; Heo, Jeongyun; Lim, Chang-Keun; Park, Soo Young; Jang, Woo-Dong; Kim, Sehoon

    2016-04-01

    H2O2-specific peroxalate chemiluminescence is recognized as a potential signal for sensitive in vivo imaging of inflammation but the effect of underlying peroxalate-emitter energetics on its efficiency has rarely been understood. Here we report a simple nanophotonic way of boosting near-infrared chemiluminescence with no need of complicated structural design and synthesis of an energetically favored emitter. The signal enhancement was attained from the construction of a nanoparticle imaging probe (∼26 nm in size) by dense nanointegration of multiple molecules possessing unique photonic features, i.e., i) a peroxalate as a chemical fuel generating electronic excitation energy in response to inflammatory H2O2, ii) a low-bandgap conjugated polymer as a bright near-infrared emitter showing aggregation-induced emission (AIE), and iii) an energy gap-bridging photonic molecule that relays the chemically generated excitation energy to the emitter for its efficient excitation. From static and kinetic spectroscopic studies, a green-emissive BODIPY dye has proven to be an efficient relay molecule to bridge the energy gap between the AIE polymer and the chemically generated excited intermediate of H2O2-reacted peroxalates. The energy-relayed nanointegration of AIE polymer and peroxalate in water showed a 50-times boosted sensing signal compared to their dissolved mixture in THF. Besides the high H2O2 detectability down to 10(-9) M, the boosted chemiluminescence presented a fairly high tissue penetration depth (>12 mm) in an ex vivo condition, which enabled deep imaging of inflammatory H2O2 in a hair-covered mouse model of peritonitis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Comparison of the performance of the borax buffer-based HRP-enhanced reagent and the 'Lumi-Phos 530' chemiluminescence systems in the detection of biotinylated DNA.

    Science.gov (United States)

    Cercek, B; Roby, K; Siaw, M

    1995-01-01

    A comparison of two chemiluminescence methods, the borax buffer-based HRP-enhanced reagent and Lumi-Phos 530, applied to the detection of a biotinylated 30-mer DNA slot blotted onto a nylon membrane, is presented. A streptavidin-HRP and streptavidin-ALP mediated detection system was used. The HRP-enhanced system is up to 15-fold greater with respect to the signal/background ratios than the Lumi-Phos 530 system at 0.5 microgram biotinylated DNA with at least a two-fold improvement in detection sensitivity for 0.5 ng biotinylated DNA.

  14. Disposable amperometric immunosensor based on layer-by-layer ...

    Indian Academy of Sciences (India)

    Administrator

    immunosensor displays a broad linear response to AFP, the working range being 0⋅25 to 300⋅0 ng mL. –1 ... pregnant women who have high levels of AFP may indicate infants with ... and factors influencing the performance of the resulting ...

  15. Strong enhancement of the chemiluminescence of the Cu(II)-H2O2 system on addition of carbon nitride quantum dots, and its application to the detection of H2O2 and glucose.

    Science.gov (United States)

    Hallaj, Tooba; Amjadi, Mohammad; Song, Zhenlun; Bagheri, Robabeh

    2017-12-19

    The authors report that carbon nitride quantum dots (CN QDs) exert a strong enhancing effect on the Cu(II)/H 2 O 2 chemiluminescent system. Chemiluminescence (CL) intensity is enhanced by CN QDs by a factor of ~75, while other carbon nanomaterials have a much weaker effect. The possible mechanism of the effect was evaluated by recording fluorescence and CL spectra and by examining the effect of various radical scavengers. Emitting species was found to be excited-state CN QDs that produce green CL peaking at 515 nm. The new CL system was applied to the sensitive detection of H 2 O 2 and glucose (via glucose oxidase-catalyzed formation of H 2 O 2 ) with detection limits (3σ) of 10 nM for H 2 O 2 and 100 nM for glucose. The probe was employed for glucose determination in human plasma samples with satisfactory results. Graphical abstract The effect of carbon nitride quantum dots (CN QDs) on Cu(II)-H 2 O 2 chemiluminescence reaction was studied and the new CL system was applied for sensitive detection of glucose based on the glucose oxidase (GOx)-catalyzed formation of H 2 O 2 .

  16. Comparative study of β-glucan induced respiratory burst measured by nitroblue tetrazolium assay and real-time luminol-enhanced chemiluminescence assay in common carp (Cyprinus carpio L.).

    Science.gov (United States)

    Vera-Jimenez, N I; Pietretti, D; Wiegertjes, G F; Nielsen, M E

    2013-05-01

    The respiratory burst is an important feature of the immune system. The increase in cellular oxygen uptake that marks the initiation of the respiratory burst is followed by the production of reactive oxygen species (ROS) such as superoxide anion and hydrogen peroxide which plays a role in the clearance of pathogens and tissue regeneration processes. Therefore, the respiratory burst and associated ROS constitute important indicators of fish health status. This paper compares two methods for quantitation of ROS produced during the respiratory burst in common carp: the widely used, single-point measurement based on the intracellular reduction of nitroblue tetrazolium (NBT) and a real-time luminol-enhanced assay based on the detection of native chemiluminescence. Both assays allowed for detection of dose-dependent changes in magnitude of the respiratory burst response induced by β-glucans in head kidney cells of carp. However, whereas the NBT assay was shown to detect the production of only superoxide anions, the real-time luminol-enhanced assay could detect the production of both superoxide anions and hydrogen peroxide. Only the chemiluminescence assay could reliably record the production of ROS on a real-time scale at frequent and continual time intervals for time course experiments, providing more detailed information on the respiratory burst response. The real-time chemiluminescence assay was used to measure respiratory burst activity in macrophage and neutrophilic granulocyte-enriched head kidney cell fractions and total head kidney cell suspensions and proved to be a fast, reliable, automated multiwell microplate assay to quantitate fish health status modulated by β-glucans. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Capillary electrophoresis microchip coupled with on-line chemiluminescence detection

    International Nuclear Information System (INIS)

    Su Rongguo; Lin Jinming; Qu Feng; Chen Zhifeng; Gao Yunhua; Yamada, Masaaki

    2004-01-01

    In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis

  18. Detection of Explosives in a Dynamic Marine Environment Using a Moored TNT Immunosensor

    Directory of Open Access Journals (Sweden)

    Paul T. Charles

    2014-02-01

    Full Text Available A field demonstration and longevity assessment for long-term monitoring of the explosive 2,4,6-trinitrotoluene (TNT in a marine environment using an anti-TNT microfluidic immunosensor is described. The TNT immunosensor is comprised of a microfluidic device with 39 parallel microchannels (2.5 cm × 250 µm × 500 µm, L × W × D fabricated in poly(methylmethacrylate (PMMA, then chemically functionalized with antibodies possessing a high affinity for TNT. Synthesized fluorescence reporter complexes used in a displacement-based assay format were used for TNT identification. For field deployment the TNT immunosensor was configured onto a submersible moored steel frame along with frame controller, pumps and TNT plume generator and deployed pier side for intermittent plume sampling of TNT (1h increments. Under varying current and tidal conditions trace levels of TNT in natural seawater were detected over an extended period (>18 h. Overnight operation and data recording was monitored via a web interface.

  19. Advances in the use of acidic potassium permanganate as a chemiluminescence reagent: A review

    International Nuclear Information System (INIS)

    Adcock, Jacqui L.; Barnett, Neil W.; Barrow, Colin J.; Francis, Paul S.

    2014-01-01

    Graphical abstract: -- Highlights: •Analytical applications of acidic potassium permanganate chemiluminescence. •Discussion of emitting species and light-producing reaction pathways. •Influence of enhancers such as polyphosphates, formaldehyde and sulfite. •Clinical, forensic, food science, agricultural and environmental applications. -- Abstract: We review the analytical applications of acidic potassium permanganate chemiluminescence published since our previous comprehensive review in mid-2007 to early 2013. This includes a critical evaluation of evidence for the emitting species, the influence of additives such as polyphosphates, formaldehyde, sulfite, thiosulfate, lanthanide complexes and nanoparticles, the development of a generalized reaction mechanism, and the use of this chemistry in pharmaceutical, clinical, forensic, food science, agricultural and environmental applications

  20. Advances in the use of acidic potassium permanganate as a chemiluminescence reagent: A review

    Energy Technology Data Exchange (ETDEWEB)

    Adcock, Jacqui L.; Barnett, Neil W.; Barrow, Colin J.; Francis, Paul S., E-mail: psf@deakin.edu.au

    2014-01-07

    Graphical abstract: -- Highlights: •Analytical applications of acidic potassium permanganate chemiluminescence. •Discussion of emitting species and light-producing reaction pathways. •Influence of enhancers such as polyphosphates, formaldehyde and sulfite. •Clinical, forensic, food science, agricultural and environmental applications. -- Abstract: We review the analytical applications of acidic potassium permanganate chemiluminescence published since our previous comprehensive review in mid-2007 to early 2013. This includes a critical evaluation of evidence for the emitting species, the influence of additives such as polyphosphates, formaldehyde, sulfite, thiosulfate, lanthanide complexes and nanoparticles, the development of a generalized reaction mechanism, and the use of this chemistry in pharmaceutical, clinical, forensic, food science, agricultural and environmental applications.

  1. The Applications of Gold Nanoparticle-Initialed Chemiluminescence in Biomedical Detection

    Science.gov (United States)

    Liu, Zezhong; Zhao, Furong; Gao, Shandian; Shao, Junjun; Chang, Huiyun

    2016-10-01

    Chemiluminescence technique as a novel detection method has gained much attention in recent years owning to the merits of high sensitivity, wider linear ranges, and low background signal. Similarly, nanotechnology especially for gold nanoparticles has emerged as detection tools due to their unique physical and chemical properties. Recently, it has become increasingly popular to couple gold nanoparticles with chemiluminescence technique in biological agents' detection. In this review, we describe the superiority of both chemiluminescence and gold nanoparticles and conclude the different applications of gold nanoparticle-initialed chemiluminescence in biomedical detection.

  2. Development of a contactless capacitive immunosensor

    OpenAIRE

    Perruche, Brice Emmanuel

    2011-01-01

    In the present work, a label-free, contactless and capacitive immunosensor is developed using impedance spectroscopy, in the aim to perform low-cost immunoassays. Chapter 1 puts this work in perspective with some existing techniques, while a presentation of impedance theory used in this work is carried out in chapter 2. In Chapter 3, numerical simulations using a commercial finite element method software is carried out. The response of coplanar and fa...

  3. Amperometric Immunosensor for Carbofuran Detection Based on MWCNTs/GS-PEI-Au and AuNPs-Antibody Conjugate

    Directory of Open Access Journals (Sweden)

    Xiangyou Wang

    2013-04-01

    Full Text Available In this paper, an amperometric immunosensor for the detection of carbofuran was developed. Firstly, multiwall carbon nanotubes (MWCNTs and graphene sheets-ethyleneimine polymer-Au (GS-PEI-Au nanocomposites were modified onto the surface of a glass carbon electrode (GCE via self-assembly. The nanocomposites can increase the surface area of the GCE to capture a large amount of antibody, as well as produce a synergistic effect in the electrochemical performance. Then the modified electrode was coated with gold nanoparticles-antibody conjugate (AuNPs-Ab and blocked with BSA. The monoclonal antibody against carbofuran was covalently immobilized on the AuNPs with glutathione as a spacer arm. The morphologies of the GS-PEI-Au nanocomposites and the fabrication process of the immunosensor were characterized by X-ray diffraction (XRD, ultraviolet and visible absorption spectroscopy (UV-vis and scanning electron microscopy (SEM, respectively. Under optimal conditions, the immunosensor showed a wide linear range, from 0.5 to 500 ng/mL, with a detection limit of 0.03 ng/mL (S/N = 3. The as-constructed immunosensor exhibited notable performance features such as high specificity, good reproducibility, acceptable stability and regeneration performance. The results are mainly due to the excellent properties of MWCNTs, GS-PEI-Au nanocomposites and the covalent immobilization of Ab with free hapten binding sites for further immunoreaction. It provides a new avenue for amperometric immunosensor fabrication.

  4. Free radical scavenging activity of coenzyme Q measured by a chemiluminescent assay

    International Nuclear Information System (INIS)

    Battino, Maurizio; Ferri, Elida; Girotti, Stefano; Lenaz, Giorgio

    1991-01-01

    Involvement of coenzyme Q (CoQ) in anti-oxydant activities, in addition to its major redox role, has frequently been suggested in recent years. In order to elucidate if CoQ could really be engaged in scavenging free radicals produced endogenously in a biological system, an experimental system was developed in which beef heart mitochondria in the presence of a saturating NADH concentration and of rotenone produce free radicals. The presence of oxygen-reactive forms was easily detected by a luminol-dependent chemiluminescence process. The chemi-luminescence assay showed that short-chain CoQ homologues can act as pro-oxidants, enhancing free radical effects, while exogenous coenzyme Q 10 could scavenge free radicals, especially at very low concentration. In this system, exogenous CoQ 10 was more effective than α-tocopherol at the same concentration in scavenging free radicals. The molecular mechanism that leads to this activity is still unclear, but these results are of biochemical importance because they indicate that CoQ may act as an anti=oxidant in situations mimicking physiopathological conditions. This direct chemiluminescent method is promising for studies of biochemical processes which involve active oxygen species. (author). 24 refs.; 4 figs

  5. MIL-53(Fe) MOF-mediated catalytic chemiluminescence for sensitive detection of glucose.

    Science.gov (United States)

    Yi, Xueling; Dong, Wenfei; Zhang, Xiaodan; Xie, Jianxin; Huang, Yuming

    2016-12-01

    Various analytical applications of metal-organic frameworks (MOFs) have been rapidly developed in the past few years. However, the employment of MOFs as catalysts in chemiluminescence (CL) analysis is rare. Here, for the first time, we found that MIL-53(Fe) MOFs could significantly enhance the CL of luminol in the presence of H 2 O 2 in an alkaline medium. The CL intensity in the luminol-H 2 O 2 -MIL-53(Fe) system was about 20 times higher than that in the luminol-H 2 O 2 system. Moreover, the XRD pattern of MIL-53(Fe) after CL reaction was almost the same as that of the original MIL-53(Fe), confirming the catalytic role of MIL-53(Fe) in the luminol-H 2 O 2 -MIL-53(Fe) system. The possible mechanism behind the enhancing phenomenon was discussed based on the results from the CL spectra, FL probe experiments, and active oxygen species measurements. By coupling with the glucose oxidase-based catalytic oxidation reaction, a sensitive and selective CL method was developed for the detection of glucose. There is a linear relationship between the logarithm of CL intensity and the logarithm of glucose concentration in the range from 0.1 to 10 μM, and a detection limit of 0.05 μM (S/N = 3) is obtained. The proposed method has been applied to the determination of glucose in human serum samples with satisfactory results. Graphical abstract MIL-53(Fe) MOFs are found to greatly enhance the chemiluminescence emission of the luminol-H 2 O 2 system, and this finding resulted in a new chemiluminescence method for biosensing of glucose when coupled with the glucose oxidase.

  6. An ultrasensitive electrochemical immunosensor for the detection of prostate-specific antigen based on conductivity nanocomposite with halloysite nanotubes.

    Science.gov (United States)

    Li, Yueyuan; Khan, Malik Saddam; Tian, Lihui; Liu, Li; Hu, Lihua; Fan, Dawei; Cao, Wei; Wei, Qin

    2017-05-01

    A sensitive label-free amperometric electrochemical immunosensor for detection of prostate-specific antigen (PSA) was proposed in this work. The nanocomposite of halloysite nanotubes with polypyrrole shell and palladium nanoparticles (HNTs@PPy-Pd) was used as a novel signal label. The HNTs with adequate hydroxyl groups are economically available raw materials. PPy, as an electrically conducting polymer material, can be absorbed to the surface of HNTs by in situ oxidative polymerization of the pyrrole monomer and form a shell on the HNTs. The shell of PPy could not only improve the conductivity of the nanocomposite but also absorb large amounts of Pd nanoparticles (NPs). The Pd NPs with high electrocatalytic activity toward the reduction of H 2 O 2 and the HNTs@PPy-Pd nanocomposite as the analytical signal label could improve the sensitivity of the immunosensor. Under optimal conditions, the immunosensor showed a low detection limit (0.03 pg/mL) and a wide linear range (0.0001 to 25 ng/mL) of PSA. Moreover, its merits such as good selectivity, acceptable reproducibility, and stability indicate that the fabricated immunosensor has a promising application potential in clinical diagnosis. Graphical Abstract A new label-free amperometric electrochemical immunosensor based on HNTs@PPy-Pd nanocomposite for quantitative detection of PSA.

  7. A rapid and simple chemiluminescence method for screening levels of inosine and hypoxanthine in non-traumatic chest pain patients.

    Science.gov (United States)

    Farthing, Don E; Sica, Domenic; Hindle, Michael; Edinboro, Les; Xi, Lei; Gehr, Todd W B; Gehr, Lynne; Farthing, Christine A; Larus, Terri L; Fakhry, Itaf; Karnes, H Thomas

    2011-01-01

    A rapid and simple chemiluminescence method was developed for detection of inosine and hypoxanthine in human plasma. The method utilized a microplate luminometer with direct injectors to automatically dispense reagents during sample analysis. Enzymatic conversions of inosine to hypoxanthine, followed by hypoxanthine to xanthine to uric acid, generated superoxide anion radicals as a useful metabolic by-product. The free radicals react with Pholasin(®) , a sensitive photoprotein used for chemiluminescence detection, to produce measurable blue-green light. The use of Pholasin(®) and a chemiluminescence signal enhancer, Adjuvant-K™, eliminated the need for plasma clean-up steps prior to analysis. The method used 20 μL of heparinized plasma, with complete analysis of total hypoxanthine levels (inosine is metabolized to hypoxanthine using purine nucleoside phosphorylase) in approximately 3.7 min. The rapid chemiluminescence method demonstrated the capability of differentiating total hypoxanthine levels between healthy individuals, and patients presenting with non-traumatic chest pain and potential acute cardiac ischemia. The results support the potential use of chemiluminescence methodology as a diagnostic tool to rapidly screen for elevated levels of inosine and hypoxanthine in human plasma, potential biomarkers of acute cardiac ischemia. Copyright © 2009 John Wiley & Sons, Ltd.

  8. Enzyme immunosensor based on gold nanoparticles electroposition and Streptavidin-biotin system for detection of S. pullorum and S. gallinarum

    International Nuclear Information System (INIS)

    Hu, Chunmei; Dou, Wenchao; Zhao, Guangying

    2014-01-01

    A novel electrochemical enzyme immunosensor based on the electrodeposited gold nanoparticles and the multistage amplification of streptavidin-biotin affinity system for detection of Salmonella pullorum and Salmonella gallinarum (S. pullorum and S. gallinarum) was investigated in this study. The electrochemical characteristics of the stepwise modified electrodes were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), whereas the determinations of the targets of S. pullorum and S. gallinarum were carried out by CV. As shown in the results of this study, the electron transfer was promoted by the electrodeposition of gold nanoparticles, thus the communication of electrons was enhanced and the conductivity of the electrode was strengthened too. Moreover, the number of the conjugated bio-molecules was elevated greatly by the electrodeposited gold nanoparticles and the streptavidin-biotin, which contributed to the integration of the following modifications and amplification of the current response signal. Under the optimized working conditions, the sensor showed a good performance with a linear response range from 10 2 CFU/ml to10 9 CFU/ml, the detection limit for S. pullorum and S. gallinarum determination was 1.95 × 10 2 CFU/ml (S/N = 3). The proposed enzyme immunosensor with high sensitivity, good specificity, acceptable accuracy and reproducibility, and low detection limit characteristics could be a promising analytical tool in detection of S. pullorum and S. gallinarum in practical samples and a model for the development of immunosensor of other bacterium of interests

  9. Effect of the dimetilsulfoxido in the response chemiluminescent and the consumption of oxygen of neutrophils activated human

    International Nuclear Information System (INIS)

    Garcia, J.

    2001-01-01

    Dimethylsulfoxide (DMSO), a hydroxyl radical scavenger, exerted a dose dependent inhibition on the luminol and lucigenin-enhanced chemiluminescent responses of human neutrophils activated with soluble and particulate stimulants. DMSO inhibition of the luminol chemiluminescense induced by calcium ionophore A23187 was probably due to OH scavenging, whereas inhibition of the lucigenin chemiluminescence suggested DMSO negatively affects the NADPH-dependent membrane oxidase of neutrophils. In agreement with this, DMSO moderately inhibited O2 consumption in PMN suspensions stimulated with chemotactic peptide and opsonized zymosan-induced luminol chemiluminescense was observed only when added before or in conjunction with stimulants, whereas A23187-induced chemiluminescense was inhibited by DMSO regardless of time of addition. Washing of DMSO-treated PMN resulted in increased luminol enhanced chemiluminescense in response to chemotactic peptide and opsonized zymosan. This is consistent with the idea that DMSO may be interfering with activation of the membrane subunits of the oxidase by translocation and docking of the cytoplasmic, regulatory subunits. These data imply that DMSO inhibits neutrophil chemiluminescense both by OH scavenging and interfering with oxidase activation. Key words:Dimethylsulfoxide, chemiluminescent, luminol, lucigenin,neutrophils [es

  10. Comparison between a Direct-Flow SPR Immunosensor for Ampicillin and a Competitive Conventional Amperometric Device: Analytical Features and Possible Applications to Real Samples

    Science.gov (United States)

    Tomassetti, Mauro; Merola, Giovanni; Martini, Elisabetta; Campanella, Luigi; Sanzò, Gabriella; Favero, Gabriele; Mazzei, Franco

    2017-01-01

    In this research, we developed a direct-flow surface plasmon resonance (SPR) immunosensor for ampicillin to perform direct, simple, and fast measurements of this important antibiotic. In order to better evaluate the performance, it was compared with a conventional amperometric immunosensor, working with a competitive format with the aim of finding out experimental real advantages and disadvantages of two respective methods. Results showed that certain analytical features of the new SPR immunodevice, such as the lower limit of detection (LOD) value and the width of the linear range, are poorer than those of a conventional amperometric immunosensor, which adversely affects the application to samples such as natural waters. On the other hand, the SPR immunosensor was more selective to ampicillin, and measurements were more easily and quickly attained compared to those performed with the conventional competitive immunosensor. PMID:28394296

  11. Sensitive determination of 4-nitrophenol based on its enhancement of a peroxyoxalate chemiluminescence system containing graphene oxide quantum dots and fluorescein

    International Nuclear Information System (INIS)

    Chen, Donghua; Peng, Rulin; Zhou, Hong; Liu, Hui

    2016-01-01

    Graphene oxide quantum dots (GOQD) are capable of enhancing the green chemiluminescence (CL) of the system composed of bis (2,4,6-trichlorophenyl) oxalate, hydrogen peroxide and fluorescein (TCPO/H_2O_2/fluorescein). It was found that 4-nitrophenol (4-NP) causes a further enhancement of the system, and this was exploited to develop a CL detection scheme for 4-NP. The optimum reaction concentrations were established, and under these conditions the calibration plot is linear in the 1.0 to 300 pmol L"−"1 concentration range, with a 0.3 pmol L"−"1 detection limit (at 3σ).We assume that CL enhancement is due to energy transfer from GOQD to fluorescein which is promoted by the interaction of 4-NP with the GOQD. The method was applied to the determination of 4-NP in spiked tap water and river water and gave recoveries between 93.4 and 107.9 %, with relative standard deviations of <4.0 %. (author)

  12. Development of optical immunosensors for detection of proteins in serum.

    Science.gov (United States)

    Kyprianou, Dimitris; Chianella, Iva; Guerreiro, Antonio; Piletska, Elena V; Piletsky, Sergey A

    2013-01-15

    The detection of proteins in biological samples such as blood, serum or plasma by biosensors is very challenging due to the complex nature of the matrix, which contains a high level of many interfering compounds. Here we show the application of a novel polymeric immobilisation matrix that helps in the detection of specific protein analytes in biological samples by surface plasmon resonance (SPR) immunosensors. This polymer matrix contains thioacetal functional groups included in the network, and these groups do not require any further activation in order to react with proteins, making it attractive for sensor fabrication. The protein prostate specific antigen (PSA) was selected as a model target analyte. A sandwich format with two primary antibodies recognising different parts (epitopes) of the analyte was used for the detection of PSA in serum. The efficiency of the reduction of non-specific binding achieved with novel polymer was compared with those of other techniques such as coating of sensor surface with polyethylene glycol (PEG), use of charged hydrophilic aspartic acid and surfactants such as Tween20. The detection limit of the polymer based immunosensor was 0.1 ng ml(-1) for free form PSA (f-PSA) in buffer and 5 ng ml(-1) in 20% serum. This is an improvement compared with similar devices reported on literature, indicating the potential of the immunosensor developed here for the analysis of real samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Kinetics and selectivity of permanganate chemiluminescence: a study of hydroxyl and amino disubstituted benzene positional isomers.

    Science.gov (United States)

    Slezak, Teo; Smith, Zoe M; Adcock, Jacqui L; Hindson, Christopher M; Barnett, Neil W; Nesterenko, Pavel N; Francis, Paul S

    2011-11-30

    Examination of the chemiluminescence reactions of dihydroxybenzenes, aminophenols and phenylenediamines with acidic potassium permanganate has provided a new understanding of the relationships between analyte structure, reaction conditions, kinetics of the light-producing pathway and emission intensity, with broad implications for this widely utilised chemiluminescence detection system. Using a permanganate reagent prepared in a polyphosphate solution and adjusted to pH 2.5, large differences in the rate of reaction with different positional isomers were observed, with the meta-substituted forms reacting far slower and therefore exhibiting much lower chemiluminescence intensities in flow analysis systems. The preliminary partial reduction of permanganate to form significant concentrations of Mn(III) increased the rate of reaction with all analytes tested, resulting in comparable or (in the case of aminophenol and phenylenediamine) even greater emission intensities for the meta-isomers, demonstrating the opportunity to tune the selectivity of the reagent towards certain classes of compound or even specific positional isomers of the same compound. Using more acidic permanganate reagents, in which polyphosphates are not required, the discrepancy between the chemiluminescence intensities was still observed, but was less prominent due to the generally faster rates of reaction. The enhancement of these chemiluminescence reactions by on-line addition of formic acid or formaldehyde can in part also be attributed to the generation of significant pools of the key Mn(III) precursor to the emitting species. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. An electrochemical immunosensor for quantitative detection of ficolin-3

    Science.gov (United States)

    San, Lili; Zeng, Dongdong; Song, Shiping; Zuo, Xiaolei; Zhang, Huan; Wang, Chenguang; Wu, Jiarui; Mi, Xianqiang

    2016-06-01

    Diabetes mellitus (DM) is one of the most common metabolic disorders in the world, of which more than 90% is type-2 diabetes mellitus (T2DM). There is a rather urgent need for reliable, sensitive and quick detection techniques in clinical application of T2DM. Ficolin-3 is a potential biomarker of T2DM, because serum ficolin-3 levels are associated with insulin resistance and predict the incidence of T2DM. Herein, a sandwich-type electrochemical immunosensor was developed for the detection of ficolin-3 in human serum. Cyclic voltammetry and the amperometric current versus time were used to characterize the performance of the immunosensor. Under optimal conditions, the detection limitation of ficolin-3 was 100 ng ml-1 and the linear dynamic range was between 2 and 50 μg ml-1. The method has ideal accuracy, excellent stability and selectivity and has wide application prospects in clinical research.

  15. Label-free impedimetric immunosensor for sensitive detection of atrazine

    Energy Technology Data Exchange (ETDEWEB)

    Ionescu, Rodica E. [Universite de Lyon, Laboratoire de Sciences Analytiques, UMR CNRS 5180, Universite Claude Bernard Lyon 1, Batiment CPE, 43 Boulevard du 11 Novembre 1918, 69622 Villeurbanne Cedex (France); Gondran, Chantal; Bouffier, Laurent [Departement de Chimie Moleculaire, UMR CNRS 5250, ICMG FR CNRS 2607, Universite Joseph Fourier, BP 53, 38041 Grenoble, Cedex 9 (France); Jaffrezic-Renault, Nicole, E-mail: nicole.jaffrezic@univ-lyon1.f [Universite de Lyon, Laboratoire de Sciences Analytiques, UMR CNRS 5180, Universite Claude Bernard Lyon 1, Batiment CPE, 43 Boulevard du 11 Novembre 1918, 69622 Villeurbanne Cedex (France); Martelet, Claude [Universite de Lyon, Laboratoire de Sciences Analytiques, UMR CNRS 5180, Universite Claude Bernard Lyon 1, Batiment CPE, 43 Boulevard du 11 Novembre 1918, 69622 Villeurbanne Cedex (France); Cosnier, Serge, E-mail: serge.cosnier@ujf-grenoble.f [Departement de Chimie Moleculaire, UMR CNRS 5250, ICMG FR CNRS 2607, Universite Joseph Fourier, BP 53, 38041 Grenoble, Cedex 9 (France)

    2010-08-30

    Impedance spectroscopy transduction combined with the immunosensor technology has been used for the determination of atrazine, a herbicide The sensor electrode was based on the immobilization of anti-atrazine antibody by affinity binding onto a polypyrrole film N-substituted by nitrilotriacetic acid NTA electrogenerated on a gold electrode. The poly NTA film was previously modified by the coordination of Cu2 ions by the chelating NTA centers. The anti-atrazine antibody Fab fragment K47 modified with histidine-tag was then anchored by affinity interactions between the histidine-tag and the coordinated Cu2. Cyclic voltammetry experiments confirm that the antibody immobilization and the resulting immunosensor were applied to the impedimetric detection of atrazine without reagent and labelling step. The immunoreaction of atrazine on the attached anti-atrazine antibody directly triggers an increase in the charge transfer resistance proportional to the atrazine concentration, allowing the detection of extremely low atrazine concentration, namely 10 pg mL{sup -1}.

  16. Electrochemical immunosensor with nanocellulose-Au composite assisted multiple signal amplification for detection of avian leukosis virus subgroup J.

    Science.gov (United States)

    Liu, Chao; Dong, Jing; Waterhouse, Geoffrey I N; Cheng, Ziqiang; Ai, Shiyun

    2018-03-15

    A sensitive sandwich-type electrochemical immunosensor was developed for the detection of avian leukosis virus subgroup J (ALV-J), which benefitted from multiple signal amplification involving graphene-perylene-3,4,9,10-tetracarboxylic acid nanocomposites (GR-PTCA), nanocellulose-Au NP composites (NC-Au) and the alkaline phosphatase (ALP) catalytic reaction. GR-PTCA nanocomposites on glassy carbon electrodes served as the immunosensor platform. Due to their excellent electrical conductivity and abundant polycarboxylic sites, the GR-PTCA nanocomposites allowed fast electron transfer and good immobilization of primary antibodies, thereby affording a strong immunosensor signal in the presence of ALV-J. The detected signal could be further amplified by the introduction of NC-Au composites as a carrier of secondary antibodies (Ab 2 ) and by harnessing the catalytic properties of Au and ALP. Under optimized testing conditions, the electrochemical immunosensor displayed excellent analytical performance for the detection of ALV-J, showing a linear current response from 10 2.08 to 10 4.0 TCID 50 /mL (TCID 50 : 50% tissue culture infective dose) with a low detection limit of 10 1.98 TCID 50 /mL (S/N = 3). In addition to high sensitivity, the immunosensor showed very good selectivity, reproducibility and operational stability, demonstrating potential application for the quantitative detection of ALV-J in clinical diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. A Fumonisins Immunosensor Based on Polyanilino-Carbon Nanotubes Doped with Palladium Telluride Quantum Dots

    Science.gov (United States)

    Masikini, Milua; Mailu, Stephen N.; Tsegaye, Abebaw; Njomo, Njagi; Molapo, Kerileng M.; Ikpo, Chinwe O.; Sunday, Christopher Edozie; Rassie, Candice; Wilson, Lindsay; Baker, Priscilla G. L.; Iwuoha, Emmanuel I.

    2015-01-01

    An impedimetric immunosensor for fumonisins was developed based on poly(2,5-dimethoxyaniline)-multi-wall carbon nanotubes doped with palladium telluride quantum dots onto a glassy carbon surface. The composite was assembled by a layer-by-layer method to form a multilayer film of quantum dots (QDs) and poly(2,5-dimethoxyaniline)-multi-wall carbon nanotubes (PDMA-MWCNT). Preparation of the electrochemical immunosensor for fumonisins involved drop-coating of fumonisins antibody onto the composite modified glassy carbon electrode. The electrochemical impedance spectroscopy response of the FB1 immunosensor (GCE/PT-PDMA-MWCNT/anti-Fms-BSA) gave a linear range of 7 to 49 ng L−1 and the corresponding sensitivity and detection limits were 0.0162 kΩ L ng−1 and 0.46 pg L−1, respectively, hence the limit of detection of the GCE/PT-PDMA-MWCNT immunosensor for fumonisins in corn certified material was calculated to be 0.014 and 0.011 ppm for FB1, and FB2 and FB3, respectively. These results are lower than those obtained by ELISA, a provisional maximum tolerable daily intake (PMTDI) for fumonisins (the sum of FB1, FB2, and FB3) established by the Joint FAO/WHO expert committee on food additives and contaminants of 2 μg kg−1 and the maximum level recommended by the U.S. Food and Drug Administration (FDA) for protection of human consumption (2–4 mg L−1). PMID:25558993

  18. An electrochemical immunosensor for brain natriuretic peptide prepared with screen-printed carbon electrodes nanostructured with gold nanoparticles grafted through aryl diazonium salt chemistry.

    Science.gov (United States)

    Serafín, V; Torrente-Rodríguez, R M; González-Cortés, A; García de Frutos, P; Sabaté, M; Campuzano, S; Yáñez-Sedeño, P; Pingarrón, J M

    2018-03-01

    A sensitive amperometric immunosensor has been prepared by immobilization of capture antibodies onto gold nanoparticles (AuNPs) grafted on a screen-printed carbon electrode (SPCE) through aryl diazonium salt chemistry using 4-aminothiophenol (AuNPs-S-Phe-SPCE). The immunosensor was designed for the accurate determination of clinically relevant levels of B-type natriuretic peptide (BNP) in human serum samples. The nanostructured electrochemical platform resulted in an ordered layer of AuNPs onto SPCEs which combined the advantages of high conductivity and improved stability of immobilized biomolecules. The resulting disposable immunosensor used a sandwich type immunoassay involving a peroxidase-labeled detector antibody. The amperometric transduction was carried out at -0.20V (vs the Ag pseudo-reference electrode) upon the addition of hydroquinone (HQ) as electron transfer mediator and H 2 O 2 as the enzyme substrate. The nanostructured immunosensors show a storage stability of at least 25 days, a linear range between 0.014 and 15ngmL -1 , and a LOD of 4pgmL -1 , which is 100 times lower than the established cut-off value for heart failure (HF) diagnosis. The performance of the immunosensor is advantageously compared with that provided with immunosensors prepared by grafting SPCE with p-phenylendiamine (H 2 N-Phe-SPCE) and attaching AuNPs by immersion into an AuNPs suspension or by electrochemical deposition, as well as with immunosensors constructed using commercial AuNPs-modified SPCEs. The developed immunosensor was applied to the successful analysis of human serum from heart failure (HF) patients upon just a 10-times dilution as sample treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Towards an Electrochemical Immunosensor System with Temperature Control for Cytokine Detection.

    Science.gov (United States)

    Metzner, Julia; Luckert, Katrin; Lemuth, Karin; Hämmerle, Martin; Moos, Ralf

    2018-04-24

    The cytokine interleukin-13 (IL-13) plays a major role in airway inflammation and is a target of new anti-asthmatic drugs. Hence, IL-13 determination could be interesting in assessing therapy success. Thus, in this work an electrochemical immunosensor for IL-13 was developed and integrated into a fluidic system with temperature control for read-out. Therefore, two sets of results are presented. First, the sensor was set up in sandwich format on single-walled carbon nanotube electrodes and was read out by applying the hydrogen peroxide⁻hydroquinone⁻horseradish peroxidase (HRP) system. Second, a fluidic system was built up with an integrated heating function realized by Peltier elements that allowed a temperature-controlled read-out of the immunosensor in order to study the influence of temperature on the amperometric read-out. The sensor was characterized at the temperature optimum of HRP at 30 °C and at 12 °C as a reference for lower performance. These results were compared to a measurement without temperature control. At the optimum operation temperature of 30 °C, the highest sensitivity (slope) was obtained compared to lower temperatures and a limit of detection of 5.4 ng/mL of IL-13 was calculated. Taken together, this approach is a first step towards an automated electrochemical immunosensor platform and shows the potential of a temperature-controlled read-out.

  20. Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital.

    Science.gov (United States)

    Tiwari, Aseem K; Pandey, Prashant K; Dara, Ravi C; Rawat, Ganesh S; Raina, Vimarsh; Bhargava, Richa

    2015-01-01

    Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. This study was designed to evaluate the performance of newly introduced VITROS(®) syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at -20°C, were used to evaluate the performance of VITROS(®) syphilis TPA assay based on enhanced chemiluminescence assay on VITROS(®) ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. VITROS(®) syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of endogenous interfering substances like free hemoglobin or fats. Performance of the VITROS(®) syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.

  1. Application of a Label-Free Immunosensor for White Spot Syndrome Virus (WSSV) in Shrimp Cultivation Water.

    Science.gov (United States)

    Waiyapoka, Thanyaporn; Deachamag, Panchalika; Chotigeat, Wilaiwan; Bunsanong, Nittaya; Kanatharana, Proespichaya; Thavarungkul, Panote; Loyprasert-Thananimit, Suchera

    2015-10-01

    White spot syndrome virus (WSSV) is a major pathogen affecting the shrimp industry worldwide. In a preliminary study, WSSV binding protein (WBP) was specifically bound to the VP26 protein of WSSV. Therefore, we have developed the label-free affinity immunosensor using the WBP together with anti-GST-VP26 for quantitative detection of WSSV in shrimp pond water. When the biological molecules were immobilized on a gold electrode to form a self-assembled monolayer, it was then used to detect WSSV using a flow injection system with optimized conditions. Binding between the different copies of WSSV and the immobilized biological molecules was detected by an impedance change (ΔZ″) in real time. The sensitivity of the developed immunosensor was in the linear range of 1.6 × 10(1)-1.6 × 10(6) copies/μl. The system was highly sensitive for the analysis of WSSV as shown by the lack of impedance change when using yellow head virus (YHV). The developed immunosensor could be reused up to 37 times (relative standard deviation (RSD), 3.24 %) with a good reproducibility of residual activity (80-110 %). The immunosensor was simple to operate, reliable, reproducible, and could be applied for the detection and quantification of WSSV in water during shrimp cultivation.

  2. Electrochemical immunosensors for the detection of survival motor neuron (SMN) protein using different carbon nanomaterials-modified electrodes.

    Science.gov (United States)

    Eissa, Shimaa; Alshehri, Nawal; Rahman, Anas M Abdel; Dasouki, Majed; Abu-Salah, Khalid M; Zourob, Mohammed

    2018-03-15

    Spinal muscular atrophy is an untreatable potentially fatal hereditary disorder caused by loss-of-function mutations in the survival motor neuron (SMN) 1 gene which encodes the SMN protein. Currently, definitive diagnosis relies on the demonstration of biallelic pathogenic variants in SMN1 gene. Therefore, there is an urgent unmet need to accurately quantify SMN protein levels for screening and therapeutic monitoring of symptomatic newborn and SMA patients, respectively. Here, we developed a voltammetric immunosensor for the sensitive detection of SMN protein based on covalently functionalized carbon nanofiber-modified screen printed electrodes. A comparative study of six different carbon nanomaterial-modified electrodes (carbon, graphene (G), graphene oxide (GO), single wall carbon nanotube (SWCNT), multi-wall carbon nanotube (MWCNT), and carbon nanofiber (CNF)) was performed. 4-carboxyphenyl layers were covalently grafted on the six electrodes by electroreduction of diazonium salt. Then, the terminal carboxylic moieties on the electrodes surfaces were utilized to immobilize the SMN antibody via EDC/NHS chemistry and to fabricate the immunosensors. The electrochemical characterization and analytical performance of the six immunosensors suggest that carbon nanofiber is a better electrode material for the SMN immunosensor. The voltammetric SMN carbon nanofiber-based immunosensor showed high sensitivity (detection limit of 0.75pg/ml) and selectivity against other proteins such as cystic fibrosis transmembrane conductance regulator (CFTR) and dystrophin (DMD). We suggest that this novel biosensor is superior to other developed assays for SMN detection in terms of lower cost, higher sensitivity, simplicity and capability of high throughput screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Highly luminescent S,N co-doped carbon quantum dots-sensitized chemiluminescence on luminol-H2 O2 system for the determination of ranitidine.

    Science.gov (United States)

    Chen, Jianqiu; Shu, Juan; Chen, Jiao; Cao, Zhiran; Xiao, An; Yan, Zhengyu

    2017-05-01

    S,N co-doped carbon quantum dots (N,S-CQDs) with super high quantum yield (79%) were prepared by the hydrothermal method and characterized by transmission electron microscopy, photoluminescence, UV-Vis spectroscopy and Fourier transformed infrared spectroscopy. N,S-CQDs can enhance the chemiluminescence intensity of a luminol-H 2 O 2 system. The possible mechanism of the luminol-H 2 O 2 -(N,S-CQDs) was illustrated by using chemiluminescence, photoluminescence and ultraviolet analysis. Ranitidine can quench the chemiluminescence intensity of a luminol-H 2 O 2 -N,S-CQDs system. So, a novel flow-injection chemiluminescence method was designed to determine ranitidine within a linear range of 0.5-50 μg ml -1 and a detection limit of 0.12 μg ml -1 . The method shows promising application prospects. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions

    Czech Academy of Sciences Publication Activity Database

    Sklenářová, H.; Voráčová, Ivona; Chocholouš, P.; Polášek, M.

    2017-01-01

    Roč. 184, APR (2017), s. 235-241 ISSN 0022-2313 Institutional support: RVO:68081715 Keywords : quantum dots * chemiluminescence * sequentialinjectionanalysis Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.686, year: 2016

  5. Magnetic beads-based electrochemical immunosensor for monitoring allergenic food proteins

    Czech Academy of Sciences Publication Activity Database

    Čadková, M.; Metelka, R.; Holubová, L.; Horák, Daniel; Dvořáková, V.; Bílková, Z.; Korecká, L.

    2015-01-01

    Roč. 484, 1 September (2015), s. 4-8 ISSN 0003-2697 R&D Projects: GA ČR GAP206/12/0381 Institutional support: RVO:61389013 Keywords : electrochemical immunosensor * magnetic particles * ovalbumin Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.243, year: 2015

  6. Fluorescence and chemiluminescence behavior of distyrylbenzene bearing two arms of dipicolylaminomethyl groups: Interactions with zinc ion and ATP

    Science.gov (United States)

    Motoyoshiya, Jiro; Wada, Jun-ya; Itoh, Keiko; Wakabayashi, Kazuaki; Maruyama, Takayuki; Ono, Kazuki; Fukasawa, Kota; Fujimoto, Tetsuya; Akaiwa, Yuji; Nonaka, Eiji

    2018-04-01

    The absorption and fluorescence spectral study of the distyrylbenzene bearing two arms of the dipicolylaminomethyl groups, the effective ligands for Zn2+, was studied in the presence of Zn2+ and ATP. Upon complexation of the distyrylbenzene with zinc ions in acetonitrile, enhancement of the fluorescence intensity was observed due to inhibition of intramolecular PET (photo-induced electron transfer) quenching, but no effect was found in aqueous media because the equilibrium laid to the free form of the ligands. In contrast, the addition of ATP disodium salt was effective to enhance the fluorescence intensity of the combination of the distyrylbenzne and Zn2+ in aqueous media. This assembly was applied to the peroxyoxalate chemiluminescence system and a significant increase in the intensity was observed, which provides a potential detection for ATP by chemiluminescence.

  7. Graphene-based chemiluminescence resonance energy transfer for homogeneous immunoassay.

    Science.gov (United States)

    Lee, Joon Seok; Joung, Hyou-Arm; Kim, Min-Gon; Park, Chan Beum

    2012-04-24

    We report on chemiluminescence resonance energy transfer (CRET) between graphene nanosheets and chemiluminescent donors. In contrast to fluorescence resonance energy transfer, CRET occurs via nonradiative dipole-dipole transfer of energy from a chemiluminescent donor to a suitable acceptor molecule without an external excitation source. We designed a graphene-based CRET platform for homogeneous immunoassay of C-reactive protein (CRP), a key marker for human inflammation and cardiovascular diseases, using a luminol/hydrogen peroxide chemiluminescence (CL) reaction catalyzed by horseradish peroxidase. According to our results, anti-CRP antibody conjugated to graphene nanosheets enabled the capture of CRP at the concentration above 1.6 ng mL(-1). In the CRET platform, graphene played a key role as an energy acceptor, which was more efficient than graphene oxide, while luminol served as a donor to graphene, triggering the CRET phenomenon between luminol and graphene. The graphene-based CRET platform was successfully applied to the detection of CRP in human serum samples in the range observed during acute inflammatory stress.

  8. Double electrochemical covalent coupling method based on click chemistry and diazonium chemistry for the fabrication of sensitive amperometric immunosensor.

    Science.gov (United States)

    Qi, Honglan; Li, Min; Zhang, Rui; Dong, Manman; Ling, Chen

    2013-08-20

    A double electrochemical covalent coupling method based on click chemistry and diazonium chemistry for the fabrication of sensitive amperometric immunosensor was developed. As a proof-of-concept, a designed alkyne functionalized human IgG was used as a capture antibody and a HRP-labeled rabbit anti-goat IgG was used as signal antibody for the determination of the anti-human IgG using the sandwich model. The immunosensor was fabricated by electrochemically grafting a phenylazide on the surface of a glassy carbon electrode, and then, by coupling the alkyne functionalized human IgG with the phenylazide group through an electro-click chemistry in the presence of Cu(II). The amperometric measurement for the determination of the anti-human IgG was performed after the fabricated immunosensor was incubated with the target anti-human IgG and then with the HRP-labeled anti-goat IgG at -0.25V in 0.10M PBS (pH 7.0) containing 0.1mM hydroquinone and 2.0mM H2O2. The results showed that the increased current was linear with the logarithm of the concentration of the anti-human IgG in the range from 1.0×10(-10)g mL(-1) to 1.0×10(-8)g mL(-1) with a detection limit of 3×10(-11)g mL(-1). Furthermore, the feasibility of the double electrochemical covalent coupling method proposed in this work for fabricating the amperometric immunosensor array was explored. This work demonstrates that the double electrochemical covalent coupling method is a promising approach for the fabrication of the immunosensor and immunosensor array. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Enzyme-less electrochemical displacement heterogeneous immunosensor for diclofenac detection.

    Science.gov (United States)

    Nguyen, T T K; Vu, T T; Anquetin, G; Tran, H V; Reisberg, S; Noël, V; Mattana, G; Nguyen, Q V; Dai Lam, Tran; Pham, M C; Piro, B

    2017-11-15

    We describe an electrochemical immunosensor based on functionalization of a working electrode by electrografting two functional diazonium salts. The first one is a molecular probe, diclofenac, coupled with an arylamine onto which a specific antibody is immobilized by affinity interactions; the second is a redox probe (a quinone) also coupled with an arylamine, able to transduce the hapten-antibody association into a change in electroactivity. The steric hindrance induced by the antibody leads to a current decrease upon binding of the antibody on the grafted molecular probe; conversely, when diclofenac is present in solution, a displacement equilibrium occurs between the target diffusing into the solution and the grafted probe. This leads to dissociation of the antibody from the electrode surface, event which is transduced into a current increase ("signal-on" detection). The detection limit is ca. 20 fM, corresponding to 6pgL -1 diclofenac, which is competitive compared to other label-free immunosensors. We demonstrate that the sensor is selective and is able to quantify diclofenac in tap water. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Copper oxide assisted cysteine hierarchical structures for immunosensor application

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Chandra Mouli [Biomedical Instrumentation Section, CSIR-National Physical Laboratory, New Delhi 110012 (India); Department of Chemistry, Faculty of Science, Banaras Hindu University, Varanasi 221005 (India); Sumana, Gajjala, E-mail: sumanagajjala@gmail.com [Biomedical Instrumentation Section, CSIR-National Physical Laboratory, New Delhi 110012 (India); Tiwari, Ida [Department of Chemistry, Faculty of Science, Banaras Hindu University, Varanasi 221005 (India)

    2014-09-08

    The present work describes the promising electrochemical immunosensing strategy based on copper (II) assisted hierarchical cysteine structures (CuCys) varying from star to flower like morphology. The CuCys having average size of 10 μm have been synthesised using L-Cysteine as initial precursor in presence of copper oxide under environmentally friendly conditions in aqueous medium. To delineate the synthesis mechanism, detailed structural investigations have been carried out using characterization techniques such as X-ray diffraction, transmission electron microscopy, and Fourier transform infrared spectroscopy. The electrochemical behaviour of self-assembled CuCys on gold electrode shows surface controlled electrode reaction with an apparent electron transfer rate constant of 3.38 × 10{sup −4 }cm s{sup −1}. This innovative platform has been utilized to fabricate an immunosensor by covalently immobilizing monoclonal antibodies specific for Escherichia coli O157:H7 (E. coli). Under the optimal conditions, the fabricated immunosensor is found to be sensitive and specific for the detection of E. coli with a detection limit of 10 cfu/ml.

  11. Label-Free QCM Immunosensor for the Detection of Ochratoxin A

    Directory of Open Access Journals (Sweden)

    Şerife Şeyda Pirinçci

    2018-04-01

    Full Text Available Ochratoxin A (OTA is a potent mycotoxin that poses a risk in food and feed moieties and subject to worldwide regulation. Laboratory-based analytical methods are traditionally employed for reliable OTA quantification, but these methods cannot provide rapid and on-site analysis, where biosensors fill this gap. In this study a label-free quartz crystal microbalance (QCM-based immunosensor for the detection of OTA, which is one of the most important small molecule contaminants, was developed by direct immobilization of OTA to amine-bearing sensor surfaces using 1-ethyl-3-(3-dimethylaminopropyl carbodiimide (EDC/N-Hydroxysuccinimide (NHS chemistry. The protein-free sensor surface enabled regeneration of sensor surface with 50 mM NaOH and 1% SDS up to 13 times without loss of performance, which would disrupt a protein-containing sensor surface. We developed a QCM immunosensor using the developed sensor surface with a 17.2–200 ng/mL detection range which can be used for on-site detection of feedstuffs.

  12. Bio- and chemiluminescence imaging in analytical chemistry

    International Nuclear Information System (INIS)

    Roda, Aldo; Guardigli, Massimo; Pasini, Patrizia; Mirasoli, Mara; Michelini, Elisa; Musiani, Monica

    2005-01-01

    Bio- and chemiluminescence imaging techniques combine the high sensitivity of bio- and chemiluminescence detection with the ability of current light imaging devices to localize and quantify light emission down to the single-photon level. These techniques have been successfully exploited for the development of sensitive analytical methods relying on the evaluation of the spatial distribution of the light emitted from a target sample. In this paper, we report on recent applications of bio- and chemiluminescence imaging for in vitro and in vivo assays, including: quantitative assays performed in various analytical formats, such as microtiter plates, microarrays and miniaturized analytical devices, used in the pharmaceutical, clinical, diagnostic and environmental fields; luminescence imaging microscopy based on enzymatic, immunohistochemical and in situ hybridization reactions for the localization of metabolites, enzymes, antigens and gene sequences in cells and tissues; whole-body luminescence imaging in live animals for evaluating biological and pathological processes and for pharmacological studies

  13. Liver Cancer Detection by a Simple, Inexpensive and Effective Immunosensor with Zinc Oxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    Congo Tak-Shing Ching

    2015-11-01

    Full Text Available Regular monitoring of blood α-fetoprotein (AFP and/or carcino-embryonic antigen (CEA levels is important for the routine screening of liver cancer. However, AFP and CEA have a much lower specificity than des-γ-carboxyprothrombin (DCP to detect liver cancer. Therefore, the study reported here was designed, to develop a screen-printed DCP immunosensor incorporating zinc oxide nanoparticles, for accurate determination of DCP. The designed immunosensor shows low detection limits for the detection of DCP: 0.440 ng/mL (based on impedance measurement, 0.081 ng/mL (based on real part of impedance measurement and 0.078 ng/mL (based on imaginary part of impedance measurement, within the range of 3.125 ng/mL to 2000 ng/mL. In addition, there was little interference to DCP determination by molecules such as Na+, K+, Ca2+, Cl−, glucose, urea, and uric acid. It is therefore concluded that the DCP immunosensor developed and reported here is simple, inexpensive and effective, and shows promise in the rapid screening of early-stage liver cancer at home with a point-of-care approach.

  14. Evaluation of enhanced chemiluminescence enzymeimmunoassay(CLEIA) in the determination of thyrotropin(TSH) using amerlite system

    International Nuclear Information System (INIS)

    Lee, Chae H.; Kim, Hwan k.; Kim, Jin Gyu

    1989-01-01

    The determination of thyrotropin(TSH) is useful in diagnosis of thyroid diseases. And the widely-used method for the determination of thyrotropin is radioimmunoassay so far because of its sensitivity. But its radiohazard and relatively short half-life of isotopes necessitates alternative methods. So many novel non-isotopic immunoassays are developed and now replacing RIA in routine laboratory measurements. We evaluated the enhanced chemiluminescence enzymeimmunoassay (Amerlite, Amersham International plc., U.K.) for the determination of serum TSH. We got good precision result with control sera. Within-assay and between-assay precision revealed less than 10%(C.V.) respectively. And comparision with CLEIA to RIA showed good correlation (y=0.648x + 0.170, r=0.978, y=value of CLEIA, x=values of RIA, n=35). We also got good correlation between singletons and duplicates result from 35 patients sera (y=0.967x + 0.0281, r=0.997, y=values of singletons, x=values of duplicates). We concluded that CLEIA is vary reliable and economic method for the determination of human TSH substitutive for RIA because of its precision and unnecessary duplicate measurements. (Author)

  15. Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sklenářová, Hana, E-mail: sklenarova@faf.cuni.cz [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic); Voráčová, Ivona [Institute of Analytical Chemistry of the CAS, v. v. i., Brno (Czech Republic); Chocholouš, Petr; Polášek, Miroslav [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic)

    2017-04-15

    The effect of 0.01–100 µmol L{sup −1} Quantum Dots (QDs) with different emission wavelengths (520–640 nm) and different surface modifications (mercaptopropionic, mercaptoundecanoic, thioglycolic acids and mercaptoethylamine) on permanganate-induced and luminol–hydrogen peroxide chemiluminescence (CL) was studied in detail by a sequential injection technique using a spiral detection flow cell and a flow-batch detection cell operated in flow and stop-flow modes. In permanganate CL system no significant enhancement of the CL signal was observed while for the luminol–hydrogen peroxide CL substantial increase (>100% and >90% with the spiral detection cell in flow and stop-flow modes, respectively) was attained for CdTe QDs. Enhancement exceeding 120% was observed for QDs with emissions at 520, 575 and 603 nm (sizes of 2.8 nm, 3.3 nm and 3.6 nm) using the flow-batch detection cell in the stop-flow mode. Pronounced effect was noted for surface modifications while mercaptoethylamine was the most efficient in CL enhancement compared to mercaptopropionic acid the most commonly applied coating. Significant difference between results obtained in flow and flow-batch conditions based on the entire kinetics of the extremely fast CL reaction was discussed. The increase of the CL signal was always accompanied by reduced lifetime of the CL emission thus application of QDs in flow techniques should be always coupled with the study of the CL lifetime.

  16. Simultaneous determination of isoniazid and p-aminosalicylic acid by capillary electrophoresis using chemiluminescence detection.

    Science.gov (United States)

    Zhang, Xinfeng; Xuan, Yuelan; Sun, Aimin; Lv, Yi; Hou, Xiandeng

    2009-01-01

    It was found that isoniazid (ISO) or p-aminosalicylic acid (PAS) could enhance the chemiluminescence (CL) emission from Cu (II)-luminol-hydrogen peroxide system, and the increased chemiluminescence signals were proportional to their concentrations, respectively. Based on this phenomenon, a chemiluminescence method coupled to capillary electrophoresis (CE) was established for simultaneous determination of ISO and PAS. The CE conditions including running buffer and running voltage were investigated in detail. The effects of the pH of H(2)O(2) solution and the concentrations of luminol, H(2)O(2) and Cu (II) on the CL signal were also investigated carefully. Under the optimized conditions, the analysis could be accomplished within 10 min, with the limits of detection of 0.3 microg mL(-1) for ISO and 1.1 microg mL(-1) for PAS, corresponding to 7.2 and 26.4 pg per injection (24 nL), respectively. Finally, the method was validated by determining the two analytes in pharmaceutical preparation and spiked human serum samples. The results of pharmaceutical tablet analysis were in good agreement with the labeled amounts. The recoveries for ISO and PAS in human serum were in the range of 92-104% and 90-113%, respectively. Copyright 2008 John Wiley & Sons, Ltd.

  17. Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital

    Directory of Open Access Journals (Sweden)

    Aseem K Tiwari

    2015-01-01

    Full Text Available Context: Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. Aims: This study was designed to evaluate the performance of newly introduced VITROS ® syphilis Treponema pallidum agglutination (TPA assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. Materials and Methods: A total of 108 random blood units collected from the donors (both voluntary and replacement donors and 28 known syphilis sero-reactive samples stored at −20°C, were used to evaluate the performance of VITROS ® syphilis TPA assay based on enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. Results: VITROS ® syphilis TPA showed 100% sensitivity and specificity with precision (20 days study of <10% co-efficient of variation. There was no cross-reactivity with other viral and auto-immune antibodies. No interference was observed from endogenous interfering substances like free hemoglobin or fats. Conclusions: Performance of the VITROS ® syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.

  18. High-performance liquid chromatographic assay of parabens in wash-off cosmetic products and foods using chemiluminescence detection

    International Nuclear Information System (INIS)

    Zhang Qunlin; Lian Mei; Liu Lijuan; Cui Hua

    2005-01-01

    A new method for the simultaneous determination of parabens including methylparaben, ethylparaben, propylparaben, and butylparaben by high-performance liquid chromatography (HPLC) coupled with chemiluminescence detection was developed. The procedure was based on the chemiluminescent enhancement by parabens of the cerium(IV)-rhodamine 6G system in the strong sulfuric acid medium. The good separation of parabens was carried out with an isocratic elution using a mixture of methanol and water (60:40, v/v) within 8.5 min. Under the optimized conditions, a linear working range extends three orders of magnitude with the relative standard deviations of intra- and inter-day precision below 4.5%, and the detection limits were 1.9 x 10 -9 , 2.7 x 10 -9 , 3.9 x 10 -9 , and 5.3 x 10 -9 g ml -1 for methylparaben, ethylparaben, propylparaben, and butylparaben, respectively. The chemiluminescence reaction was well compatible with the mobile phase of high-performance liquid chromatography. The proposed method has been successfully applied to the assay of parabens in wash-off cosmetic products and foods with the minimal sample preparation

  19. Optical waveguide lightmode spectroscopy technique-based immunosensor development for aflatoxin B1 determination in spice paprika samples.

    Science.gov (United States)

    Majer-Baranyi, Krisztina; Zalán, Zsolt; Mörtl, Mária; Juracsek, Judit; Szendrő, István; Székács, András; Adányi, Nóra

    2016-11-15

    Optical waveguide lightmode spectroscopy (OWLS) technique has been applied to label-free detection of aflatoxin B1 in a competitive immunoassay format, with the aim to compare the analytical goodness of the developed OWLS immunosenor with HPLC and enzyme-linked immunosorbent assay (ELISA) methods for the detection of aflatoxin in spice paprika matrix. We have also assessed applicability of the QuEChERS method prior to ELISA measurements, and the results were compared to those obtained by traditional solvent extraction followed by immunoaffinity clean-up. The AFB1 content of sixty commercial spice paprika samples from different countries were measured with the developed and optimized OWLS immunosensor. Comparing the results from the indirect immunosensor to that obtained by HPLC or ELISA provided excellent correlation (with regression coefficients above 0.94) indicating that the competitive OWLS immunosensor has a potential for quick determination of aflatoxin B1 in paprika samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Multiplexed determination of human growth hormone and prolactin at a label free electrochemical immunosensor using dual carbon nanotube-screen printed electrodes modified with gold and PEDOT nanoparticles.

    Science.gov (United States)

    Serafín, V; Martínez-García, G; Agüí, L; Yáñez-Sedeño, P; Pingarrón, J M

    2014-09-21

    A label-free dual electrochemical immunosensor was constructed for the multiplexed determination of human growth (hGH) and prolactin (PRL) hormones. The immunosensor used an electrochemical platform composed of carbon nanotube-screen printed carbon electrodes (CNT/SPCEs) modified with poly(ethylene-dioxythiophene) (PEDOT) and gold nanoparticles, on which the corresponding hGH and PRL antibodies were immobilized. The affinity reactions were monitored by measuring the decrease in the differential pulse voltammetric oxidation response of the redox probe dopamine. The experimental variables involved in the preparation of both AuNP/PEDOT/CNT/SPC modified electrodes and the dual immunosensor were optimized. The immunosensor exhibited an improved analytical performance for hGH and PRL with respect to other electrochemical immunosensor designs, showing wide ranges of linearity and low detection limits of 4.4 and 0.22 pg mL(-1), respectively. An excellent selectivity against other hormones and in the presence of ascorbic and uric acids was found. The usefulness of the dual immunosensor for the simultaneous analysis of hGH and PRL was demonstrated by analyzing human serum and saliva samples spiked with the hormones at different concentration levels.

  1. A membrane-based immunosensor for the analysis of the herbicide isoproturon.

    Science.gov (United States)

    Baskeyfield, Damian E H; Davis, Frank; Magan, Naresh; Tothill, Ibtisam E

    2011-08-12

    A membrane based heterogeneous competitive enzyme-linked immunosorbent assay (ELISA) was used in this work to develop an immunosensor for the detection of a common herbicide, isoproturon. A screen-printed carbon working electrode with carbon counter and silver-silver chloride pseudo-reference electrode was utilized incorporating a membrane fixed into intimate contact with the working electrode to facilitate signal transduction. The membrane containing an immobilized isoproturon-ovalbumin conjugate was laminated onto the carbon working electrode and horseradish peroxidase (HRP) labeled polyclonal antibody was then applied for the competitive assay. Two different amperometric systems, hydroquinone and o-phenylenediamine (OPD) mediation reduction were utilised and the properties of the resultant sensors were compared. A flow injection apparatus was also developed utilising the immunosensor. Limits of detection for isoproturon (LLD(90)) were found to be as low as 0.84 ng mL(-1). The senor was also validated using spiked extracted soil samples and also isoproturon contaminated samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Coreactant-free and Label-free Eletrochemiluminescence Immunosensor for Copeptin Based on Luminescent Immuno-Gold Nanoassemblys.

    Science.gov (United States)

    Han, Zhili; Shu, Jiangnan; Jiang, Qiaoshi; Cui, Hua

    2018-04-25

    In this work, the eletrochemiluminescence (ECL) behavior of Cu 2+ /cysteine complexes and N-(aminobutyl)-N-(ethylisoluminol) (ABEI) functionalized gold nanoparticles combined with chitosan (Cu 2+ -Cys-ABEI-GNPs-CS) were studied by cyclic voltammetry and a double-step potential, which exhibited excellent ECL properties without any coreactant. It was found that the ECL intensity of Cu 2+ -Cys-ABEI-GNPs-CS could increase at least one order of magnitude compared with that of Cu 2+ -Cys-ABEI-GNPs. Furthermore, a coreactant-free and label-free ECL immunosensor has been established for the determination of early acute myocardial infarction biomarker copeptin based on luminescent immuno-gold nanoassemblys consisting of Cu 2+ -Cys-ABEI-GNPs-CS and immuno-gold nanoparticles prepared by connecting copeptin antibody with trisodium citrate stabilized gold nanoparticles. In the presence of copeptin, an obvious decrease in ECL intensity was observed due to the formation of antibody-antigen immunocomplex, which could be used for the determination of copeptin in the range of 2.0×10 -14 -1.0×10 -11 mol/L with a detection limit of 5.18×10 -15 mol/L. The detection limit of the ECL immunosensor is at least two orders of magnitude lower than that of sandwich immunoassays based on labeling technology. And the ECL immunosensor does not need any coreactant, and avoids complicated labeling and purification procedure. It is ultrasensitive, simple, specific and low-cost. This work reveals that the proposed luminescent immuno-gold nanoassemblys are ideal nanointerfaces for the construction of immunosensors. The proposed strategy may be used for the determination of other antigens if corresponding antibodies are available.

  3. A disposable electrochemical immunosensor for prolactin involving affinity reaction on streptavidin-functionalized magnetic particles

    International Nuclear Information System (INIS)

    Moreno-Guzman, Maria; Gonzalez-Cortes, Araceli; Yanez-Sedeno, Paloma; Pingarron, Jose M.

    2011-01-01

    A novel electrochemical immunosensor was developed for the determination of the hormone prolactin. The design involved the use of screen-printed carbon electrodes and streptavidin-functionalized magnetic particles. Biotinylated anti-prolactin antibodies were immobilized onto the functionalized magnetic particles and a sandwich-type immunoassay involving prolactin and anti-prolactin antibody labelled with alkaline phosphatase was employed. The resulting bio-conjugate was trapped on the surface of the screen-printed electrode with a small magnet and prolactin quantification was accomplished by differential pulse voltammetry of 1-naphtol formed in the enzyme reaction using 1-naphtyl phosphate as alkaline phosphatase substrate. All variables involved in the preparation of the immunosensor and in the electrochemical detection step were optimized. The calibration plot for prolactin exhibited a linear range between 10 and 2000 ng mL -1 with a slope value of 7.0 nA mL ng -1 . The limit of detection was 3.74 ng mL -1 . Furthermore, the modified magnetic beads-antiprolactin conjugates showed an excellent stability. The immunosensor exhibited also a high selectivity with respect to other hormones. The analytical usefulness of the immnunosensor was demonstrated by analyzing human sera spiked with prolactin at three different concentration levels.

  4. A disposable electrochemical immunosensor for prolactin involving affinity reaction on streptavidin-functionalized magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Guzman, Maria; Gonzalez-Cortes, Araceli [Department of Analytical Chemistry, Faculty of Chemistry, University Computense of Madrid, 28040 Madrid (Spain); Yanez-Sedeno, Paloma, E-mail: yseo@quim.ucm.es [Department of Analytical Chemistry, Faculty of Chemistry, University Computense of Madrid, 28040 Madrid (Spain); Pingarron, Jose M. [Department of Analytical Chemistry, Faculty of Chemistry, University Computense of Madrid, 28040 Madrid (Spain)

    2011-04-29

    A novel electrochemical immunosensor was developed for the determination of the hormone prolactin. The design involved the use of screen-printed carbon electrodes and streptavidin-functionalized magnetic particles. Biotinylated anti-prolactin antibodies were immobilized onto the functionalized magnetic particles and a sandwich-type immunoassay involving prolactin and anti-prolactin antibody labelled with alkaline phosphatase was employed. The resulting bio-conjugate was trapped on the surface of the screen-printed electrode with a small magnet and prolactin quantification was accomplished by differential pulse voltammetry of 1-naphtol formed in the enzyme reaction using 1-naphtyl phosphate as alkaline phosphatase substrate. All variables involved in the preparation of the immunosensor and in the electrochemical detection step were optimized. The calibration plot for prolactin exhibited a linear range between 10 and 2000 ng mL{sup -1} with a slope value of 7.0 nA mL ng{sup -1}. The limit of detection was 3.74 ng mL{sup -1}. Furthermore, the modified magnetic beads-antiprolactin conjugates showed an excellent stability. The immunosensor exhibited also a high selectivity with respect to other hormones. The analytical usefulness of the immnunosensor was demonstrated by analyzing human sera spiked with prolactin at three different concentration levels.

  5. An ultrasensitive sandwich type electrochemiluminescence immunosensor for triiodothyronine detection using silver nanoparticle-decorated graphene oxide as a nanocarrier.

    Science.gov (United States)

    Chou, Hung-Tao; Fu, Chien-Yu; Lee, Chi-Young; Tai, Nyan-Hwa; Chang, Hwan-You

    2015-09-15

    An ultrasensitive electrochemiluminescence (ECL) immunosensor was constructed to detect 3,3',5-triiodothyronine (T3). The system employed T3-conjugated, silver nanoparticle-decorated carboxylic graphene oxide (Ag@fGO-T3) as a carrier and anti-T3 antibody-tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)3(2+)) as a probe. The Ag@fGO-T3 and Ru(bpy)3(2+) complex could be mobilized rapidly to the anode in the reaction chamber through electrophoresis. The fGO is reduced electrochemically at the electrode, and the electrons could transfer from an anode to the Ru(bpy)3(2+). The complex is excited at the electrode and an ECL signal is produced upon reacting with tripropylamine (TPrA). Because of its large surface area and excellent conductivity, Ag@fGO could enhance ECL signal significantly in the system. Quantitative measurement of T3 could be achieved in the range from 0.1 pg/mL to 0.8 ng/mL with a detection limit of 0.05 pg/mL. In addition, the novel immunosensor showed good specificity in the presence of serum, indicating its high potential in clinical use. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Amperometric immunosensor based on multiwalled carbon nanotubes/Prussian blue/nanogold-modified electrode for determination of α-fetoprotein.

    Science.gov (United States)

    Jiang, Wen; Yuan, Ruo; Chai, Ya-Qin; Yin, Bing

    2010-12-01

    In this article, a conspicuously simple and highly sensitive amperometric immunosensor based on the sequential electrodeposition of Prussian blue (PB) and gold nanoparticles (GNPs) on multiwalled carbon nanotube (MWCNT)-modified glassy carbon electrode (GCE) surface is proposed for the detection of α-fetoprotein (AFP). By comparison with PB, the MWCNT/PB composite film had been proven to show much better electrochemical stability and a larger response current. The electrodeposited GNP film can be used not only to immobilize biomolecules but also to avoid the leakage of PB and to prevent shedding of MWCNT/PB composite film from the electrode surface. The performance and factors influencing the performance of the immunosensor were investigated. Under optimal experimental conditions, the proposed immunosensor for AFP was observed with an ultralow limit of detection (LOD) equal to 3 pg/ml (at 3δ), and the linear working range spanned the concentrations of AFP from 0.01 to 300 ng/ml. Moreover, the immunosensor, as well as a commercially available kit, was examined for use in the determination of AFP in real human serum specimens. More significant, the assay mentioned here is simpler than the traditional enzyme-linked immunosorbent assay (ELISA), and an excellent correlation of levels of AFP measured was obtained, indicating that the developed immunoassay could be a promising alternative approach for detection of AFP and other tumor markers in the clinical diagnosis. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Development of electrochemical immunosensors based on different serum antibody immobilization methods for detection of Japanese encephalitis virus

    International Nuclear Information System (INIS)

    Tran, Quang Huy; Hanh Nguyen, Thi Hong; Phan, Thi Nga; Mai, Anh Tuan; Nguyen, Thi Thuy; Vu, Quang Khue

    2012-01-01

    This paper describes the development of electrochemical immunosensors based on human serum antibodies with different immobilization methods for detection of Japanese encephalitis virus (JEV). Human serum containing anti-JEV antibodies was used to immobilize onto the surface of silanized interdigitated electrodes by four methods: direct adsorption (APTES-serum), covalent binding with a cross linker of glutaraldehyde (APTES-GA-serum), covalent binding with a cross linker of glutaraldehyde combined with anti-human IgG (APTES-GA-anti-HIgG-serum) and covalent binding with a cross linker of glutaraldehyde combined with a bioaffinity of protein A (APTES-GA-PrA-serum). Atomic force microscopy was used to verify surface characteristics of the interdigitated electrodes before and after treatment with serum antibodies. The output signal of the immunosensors was measured by the change of conductivity resulting from the specific binding of JEV antigens and serum antibodies immobilized on the electrodes, with the help of horseradish peroxidase (HRP)-labeled secondary antibody against JEV. The results showed that the APTES-GA-PrA-serum method provided the highest signal of the electrochemical immunosensor for detection of JEV antigens, with the linear range from 25 ng ml −1 to 1 μg ml −1 , and the limit of detection was about 10 ng ml −1 . This study shows a potential development of novel electrochemical immunosensors applied for virus detection in clinical samples in case of possible outbreaks

  8. A novel electrochemiluminescent immunosensor based on the quenching effect of aminated graphene on nitrogen-doped carbon quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jing; Han, Tongqian; Ma, Hongmin; Yan, Tao; Pang, Xuehui [Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China); Li, Yueyun [School of Chemical Engineering, Shandong University of Technology, Zibo 255049 (China); Wei, Qin, E-mail: sdjndxwq@163.com [Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China)

    2015-08-19

    Nitrogen-doped carbon quantum dots (N-CQDs) with an average diameter of 2 nm were synthesized by carbonization of diethylene triamine pentacetate acid (DTPA). The simple prepared N-CQDs showed excellent electrochemiluminescence (ECL) property and were used as luminophors to fabricate a sandwich-type ECL immunosensor. Aminated graphene (NH{sub 2}-G) was also synthesized and used as a label of secondary antibody. The labeled NH{sub 2}-G could effectively quench the ECL of N-CQDs modified on electrodes due to ECL resonance energy transfer (ERET). Immunological recognition which induced ECL quenching enabled the quantitative determination of biomarkers. Alpha fetoprotein (AFP) was selected as a model analyte to investigate the analytical performance of the proposed immunosensor. Under optimal conditions, a good linear relationship between ECL intensity and the logarithm of AFP concentration was obtained in the range of 0.01–100 ng mL{sup −1} with the detection limit of 3.3 pg mL{sup −1}. The proposed ECL immunosensor showed good stability, acceptable selectivity and reproducibility. - Highlights: • ECL behavior of N-CQDs was investigated. • NH{sub 2}-G for quenching N-CQDs emission was investigated. • The linearly range of the immunosensor for AFP was 0.01 ng/mL–100 ng/mL.

  9. Evaluation of Antibacterial Enrofloxacin in Eggs by Matrix Solid Phase Dispersion-Flow Injection Chemiluminescence

    Directory of Open Access Journals (Sweden)

    Xiaocui Duan

    2014-01-01

    Full Text Available The study based on the chemiluminescence (CL reaction of potassium ferricyanide and luminol in sodium hydroxide medium, enrofloxacin (ENRO could dramatically enhance CL intensities and incorporated with matrix solid-phase dispersion (MSPD technique (Florisil used as dispersant, dichloromethane eluted the target compounds. A simple flow injection chemiluminescence (FL-CL method with MSPD technique for determination of ENRO in eggs was described. Under optimal conditions, the CL intensities were linearly related to ENRO concentration ranging from 4.0×10-8 g.L−1 to 5.0×10-5 g.L−1, with a correlation coefficient of 0.9989 and detection limit of 5.0×10-9 g.L−1. The relative standard deviation was 3.6% at an ENRO concentration of 2.0×10-6 g.L−1. Our testing technique can help ensure food safety, and thus, protect public health.

  10. Rapid Determination of Phytophthora infestans sporangia Using a Surface Plasmon Resonance Immunosensor

    DEFF Research Database (Denmark)

    Skottrup, Peter; Nicolaisen, Mogens; Justesen, Annemarie Fejer

    2007-01-01

    Phytophthora infestans is the cause of late blight disease in potato and is an economically important pathogen worldwide. Early disease detection is important to implement disease control measures. In this study a surface plasmon resonance (SPR) immunosensor for detection of P. infestans sporangia...

  11. Ultrasensitive chemiluminescence of tetracyclines in the presence of MCLA

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Wangsheng; Zhu, Chenyao [School of Public Health, Nanchang University, Nanchang 330006 (China); Liu, Hongcheng [Institute of Quality Standard and Testing Technology, Yunnan Academy of Agriculture Science, 650223 Kunming (China); Liu, Jing; Cai, Hongping [School of Public Health, Nanchang University, Nanchang 330006 (China); Cheng, Xianglei, E-mail: chengxlsd@163.com [School of Public Health, Nanchang University, Nanchang 330006 (China); Wei, Lijun, E-mail: weilj7681@163.com [School of Public Health, Nanchang University, Nanchang 330006 (China)

    2017-06-15

    In this article, five tetracyclines (TCs) showed ultrasensitive chemiluminescence (CL) based on the novel CL system of methoxylated Cypridina luciferin analogues (MCLA) and Ce(IV). It was found that the CL intensity of MCLA-Ce(IV) system was enhanced 30 times by adding 10 pmol chlortetracycline. Mechanisms of MCLA-Ce(IV)-TCs were investigated by CL spectra, radical scavengers and UV spectra. The results indicated that singlet oxygen, resulting from the reaction between Ce(IV) and TCs, was involved in the enhancement of CL phenomenon. This CL system coupling with flow injection analysis was developed for the determination of five common TCs. Linear ranged from 100 fmol to 20 pmol (r>0.999) with limit of detection of 20 to 50 fmol (S/N=3). The sensitivity of the present method is comparable to that of UPLC-MS/MS detection for TCs.

  12. Luminol Chemiluminescence Catalyzed by Silver Nanoparticles for the Sensitive Determination of Penicillamine

    Directory of Open Access Journals (Sweden)

    Fakhr Eldin O. Suliman

    2018-01-01

    Full Text Available A sequential injection method for the determination of penicillamine (PA was developed based on quenching the chemiluminescence generated by oxidation of luminol by hydrogen peroxide in presence of silver nanoparticles (AgNPs. The chemiluminescence (CL of the reaction was found to greatly enhance in presence of AgNPs due to the increased catalyst surface area. The method was sensitive and found suitable for analysis of penicillamine in pharmaceutical preparations. Linear calibration curve is obtained in the range 0.2-1.0 mg mL-1 with a relative standard deviation less than 2%. A recovery percent of 102.3 ±0.2 was obtained with the tablets matrix indicating reasonable selectivity of the method for PA in tablets. The mechanism of quenching of the CL reaction was investigated by UV-Visible spectroscopy and transmission electron microscopy as well as by theoretical calculations using DFT-B3LYP method. The covalent attachment of PA to the AgNPs triggers aggregation of the particles thereby diminishing the surface significantly. The method was applied for the assay of PA in pharmaceutical preparations.

  13. Label-free immunosensor for the detection of kanamycin using Ag@Fe₃O₄ nanoparticles and thionine mixed graphene sheet.

    Science.gov (United States)

    Yu, Shujun; Wei, Qin; Du, Bin; Wu, Dan; Li, He; Yan, Liangguo; Ma, Hongmin; Zhang, Yong

    2013-10-15

    A highly sensitive label-free immunosensor for the detection of kanamycin had been developed using silver hybridized mesoporous ferroferric oxide nanoparticles (Ag@Fe₃O₄ NPs) and thionine mixed graphene sheet (TH-GS). TH was used as an electron transfer mediator. The electrical signal was greatly improved in the presence of GS due to its good electron-transfer ability. With the advantages of large specific surface area and excellent electrical conductivity, Ag@Fe₃O₄ NPs could immobilize more antibodies of kanamycin and promote the electron transfer. Cyclic voltammetry and square wave voltammetry were used to characterize the recognition of kanamycin. The proposed immunosensor showed good performances such as low detection limit (15 pg mL⁻¹), wide linear range (from 0.050 to 16 ng mL⁻¹), short analysis time (3 min), high stability, and good selectivity in the detection of kanamycin. The immunosensor was evaluated for pork meat sample, receiving satisfactory results. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. A sandwich-type electrochemical immunosensor based on in situ silver deposition for determination of serum level of HER2 in breast cancer patients.

    Science.gov (United States)

    Shamsipur, Mojtaba; Emami, Mahdi; Farzin, Leila; Saber, Reza

    2018-04-30

    The sensitive quantification of Human Epidermal growth factor Receptor 2 (HER2), as a key prognostic tumor marker, plays a critical role in screening, early diagnosis and management of breast cancer. This paper describes a sandwich-type immunoassay with silver signal enhancement strategy for highly sensitive detection of HER2. For this purpose, the target capturing step was designed by functionalization of 3-aminopropyltrimethoxysilane coated magnetite nanoparticles with antibody (antiHER2/APTMS-Fe 3 O 4 ), as a platform bioconjugate (PB), and immobilized at a bare GCE. Then, in the presence of label-free immunosensor, the PB was covered by magnetic gold nanoparticles self-assembled with thiolated antibodies (antiHER2/Hyd@AuNPs-APTMS-Fe 3 O 4 ) containing chemically reduced silver ions, as a label bioconjugate (LB). Under optimum conditions, a linear relationship between the differential pulse voltammetric (DPV) stripping signal of silver and the logarithm of HER2 concentrations was obtained in the range of 5.0 × 10 -4 -50.0ngmL -1 (R 2 = 0.9906) with a detection limit of 2.0 × 10 -5 ngmL -1 . The effectiveness of this protocol was evaluated experimentally through employing of designed immunosensor for detection of the serum level of tumor marker. The good consistency of the results with those obtained by the enzyme-linked immunosorbent assay (ELISA) conventional method (p-value of < 0.05) showed that this immunosensor can be applied for the testing of HER2 in clinical samples of breast cancer patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Chemiluminescence behavior based on oxidation reaction of rhodamine B with cerium(IV) in sulfuric acid medium

    International Nuclear Information System (INIS)

    Ma Yongjun; Jin Xiaoyong; Zhou Min; Zhang Ziyu; Teng Xiulan; Chen Hui

    2003-01-01

    The chemiluminescence (CL) of the rhodamine B (RhB)-cerium(IV) system was investigated by flow-injection. Rhodamine B was suggested to be a suitable chemiluminescent reagent in acidic conditions. When the concentration of rhodamine B was 100 mg l -1 and cerium sulfate was 1.6 mmol l -1 in sulfuric acid, the chemiluminescent intensity was found to be highest by using 0.3 mol l -1 sulfuric acid as a carrier solution. The particular chemiluminescent system could tolerate such distinct acidic environments that it was utilized for detecting many compounds that are stable in acidic solutions. Furthermore, by virtue of IR, UV-Vis and luminescence spectroscopic measurements, the chemiluminescent behavior of rhodamine B was studied and a possible mechanism for this chemiluminescent reaction was proposed. The emitter was affirmed to be a radical species due to one of the oxidation products of RhB; the chemiluminescent emissive wavelength was about 425 nm

  16. Chemiluminescence behavior based on oxidation reaction of rhodamine B with cerium(IV) in sulfuric acid medium

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yongjun; Jin Xiaoyong; Zhou Min; Zhang Ziyu; Teng Xiulan; Chen Hui

    2003-08-18

    The chemiluminescence (CL) of the rhodamine B (RhB)-cerium(IV) system was investigated by flow-injection. Rhodamine B was suggested to be a suitable chemiluminescent reagent in acidic conditions. When the concentration of rhodamine B was 100 mg l{sup -1} and cerium sulfate was 1.6 mmol l{sup -1} in sulfuric acid, the chemiluminescent intensity was found to be highest by using 0.3 mol l{sup -1} sulfuric acid as a carrier solution. The particular chemiluminescent system could tolerate such distinct acidic environments that it was utilized for detecting many compounds that are stable in acidic solutions. Furthermore, by virtue of IR, UV-Vis and luminescence spectroscopic measurements, the chemiluminescent behavior of rhodamine B was studied and a possible mechanism for this chemiluminescent reaction was proposed. The emitter was affirmed to be a radical species due to one of the oxidation products of RhB; the chemiluminescent emissive wavelength was about 425 nm.

  17. Chemiluminescence of creatinine/H2O2/Co(2+) and its application for selective creatinine detection.

    Science.gov (United States)

    Hanif, Saima; John, Peter; Gao, Wenyue; Saqib, Muhammad; Qi, Liming; Xu, Guobao

    2016-01-15

    Creatinine is an important biomarker in clinical diagnosis and biomonitoring programs as well as urinary metabolomic/metabonomics research. Current methods are either nonselective, time consuming or require heavy and expensive instruments. In this study, chemiluminescence of creatinine with hydrogen peroxide has been reported for the first time, and its chemiluminescence is remarkably enhanced in the presence of cobalt ions. By utilizing these phenomena, we have developed a sensitive and selective chemiluminescence method for creatinine determination by coupling with flow injection analysis. The calibration curve is linear in the range of 1×10(-7)-3×10(-5)mol/L with a limit of detection (S/N=3) of 7.2×10(-8)mol/L, which is adequate for detecting creatinine in the clinically accepted range. The relative standard deviation for seven measurements of 3×10(-5)mol/L creatinine is 1.2%. The chemiluminescence method was then utilized to detect creatinine in human urine samples after simple dilution with water. It takes less than 1min each measurement and the recoveries for spiked urine samples were 100-103%. The interference study demonstrates that some common species in urine, such as amino acids, ascorbic acid and creatine, have negligible effects on creatinine detection. The present method does not use expensive instruments, enzymes and separation technique. This method has the advantages of sensitivity, selectivity, simplicity, rapidity, and low cost. It holds great promise for basic or comprehensive metabolic panel, drug screening, anti-dopping, and urinary metabolomic/metabonomics research. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Faraday cage-type electrochemiluminescence immunosensor for ultrasensitive detection of Vibrio vulnificus based on multi-functionalized graphene oxide.

    Science.gov (United States)

    Guo, Zhiyong; Sha, Yuhong; Hu, Yufang; Yu, Zhongqing; Tao, Yingying; Wu, Yanjie; Zeng, Min; Wang, Sui; Li, Xing; Zhou, Jun; Su, Xiurong

    2016-10-01

    A novel Faraday cage-type electrochemiluminescence (ECL) immunosensor devoted to the detection of Vibrio vulnificus (VV) was fabricated. The sensing strategy was presented by a unique Faraday cage-type immunocomplex based on immunomagnetic beads (IMBs) and multi-functionalized graphene oxide (GO) labeled with (2,2'-bipyridine)(5-aminophenanthroline)ruthenium (Ru-NH2). The multi-functionalized GO could sit on the electrode surface directly due to the large surface area, abundant functional groups, and good electronic transport property. It ensures that more Ru-NH2 is entirely caged and become "effective," thus improving sensitivity significantly, which resembles extending the outer Helmholtz plane (OHP) of the electrode. Under optimal conditions, the developed immunosensor achieves a limit of detection as low as 1 CFU/mL. Additionally, the proposed immunosensor with high sensitivity and selectivity can be used for the detection of real samples. The novel Faraday cage-type method has shown potential application for the diagnosis of VV and opens up a new avenue in ECL immunoassay. Graphical abstract Faraday cage-type immunoassay mode for ultrasensitive detection by extending OHP.

  19. A disposable electrochemical immunosensor arrays using 4-channel screen-printed carbon electrode for simultaneous detection of Escherichia coli O157:H7 and Enterobacter sakazakii

    International Nuclear Information System (INIS)

    Dou, Wenchao; Tang, Weilu; Zhao, Guangying

    2013-01-01

    An electrochemical immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) and Enterobacter sakazakii (E. sakazakii) detection using carbon screen-printed low-density arrays is reported. The sensors were fabricated based on screen-printed carbon arrays containing four carbon working electrode, an integrated carbon counter electrodes and an integrated Ag/AgCl reference electrode. Multi-walled carbon nanotubes (MWCNTs)/sodium alginate (SA)/carboxymethyl chitosan (CMC) composite films were coated on all the working electrodes to enhance the sensitization of the electrode. Horseradish peroxidases (HRP) labeled antibodies of two bacteria were immobilize on different working electrode of the same screen-printed electrode respectively. The immobilization of MWCNTs, HRP labeled antibodies onto the screen-printed carbon electrodes was examined using atom force microscopy (AFM) and cyclic voltammetry (CV). The analytical performance of proposed immunosensor arrays toward E. sakazakii and E. coli O157:H7 was investigated by AFM and CV. Under optimal conditions, the linear range of E. sakazakii and E. coli O157:H7 were from 10 4 to 10 10 cfu/ml, with a detection limit of 4.57 × 10 3 cfu/ml (S/N = 3) and 3.27 × 10 3 cfu/ml (S/N = 3), respectively. The specificity, reproducibility, stability and accuracy of the proposed immunosensor arrays were also evaluated. Two antibodies modified work electrodes were tested and compared in terms of sensitivity and ability to recognize different pathogenic biological species

  20. FEATURES OF CHEMILUMINESCENT ACTIVITY OF NEUTROPHILIC GRANULOCYTES IN PATIENTS WITH CHRONIC GASTRITIS, CHRONIC ATROPHIC GASTRITIS AND GASTRIC CANCER

    Directory of Open Access Journals (Sweden)

    O. V. Smirnova

    2017-01-01

    Full Text Available Chronic gastritis is the most common disease of gastro-intestinal tract. Precancerous potential is among most important epidemiological features of chronic gastritis. Immune system plays a distinct role in transformation from precancerous state to malignancy. In this context, the aim of our work was a study of spontaneous and induced chemiluminescence activity of neutrophilic granulocytes in patients with chronic superficial gastritis, chronic atrophic gastritis and gastric cancer. The work presents results of comprehensive laboratory examination of patients with chronic gastritis (CG (a total of 85 persons. 25 patients with chronic atrophic gastritis (CAG, and 50 patients with gastric cancer (GC at the age of 19 to 70 years were enrolled. Control group included 115 healthy donors without gastrointestinal complaints at the age of 19 to 67 years. The study was performed with venous blood samples taken from cubital vein into Vacutainer tubes with sodium heparin (5 U/mL prior to starting any pathogenic treatment. Evaluation of spontaneous and induced chemiluminescence was performed for 90 minutes at a 36-channel “CL 3606” chemiluminescence analyzer (Russia. In our study, patients with gastric cancer showed clear unidirectional changes in chemiluminescent activity of neutrophilic granulocytes (NG. When measuring spontaneous and induced NG chemiluminescence, we diagnosed a decreased phagocytic activity characterized by prolonged time-to-peak and area under the curve for spontaneous and induced CL, thus presuming longer activation time required in cases of reduced phagocytic function. The NG activity in patients with chronic gastritis is not impaired, but, similar changes of time-to-peak and area under were detected. Chemiluminescent activity of NG is increased in the group of CAG patients, and, considering similar changes in activation time and area under the curve, NG also produce greater amount of reactive oxygen species. Thus, for all H

  1. Chemiluminescence immunoassay for prostate-specific antigen

    International Nuclear Information System (INIS)

    Zhang Xuefeng; Liu Yibing; Jia Juanjuan; Xu Wenge; Li Ziying; Chen Yongli; Han Shiquan

    2008-01-01

    The chemiluminescence immunoassay (CLIA) for serum total prostate-specific antigen (T-PSA) was developed. The reaction of luminol with hydrogen peroxide was introduced into this chemiluminescence system. The detection limit is established as 0.12 μg/L (n=10, mean of zero standard + 2SD) and the analytical recovery of PSA is 83.8%-118.7%. The intra-assay and inter-assay CVs vary from 4.4%-5.0% and 6.2%-11.7%, respectively. The experimental correlation coefficient of dilution is found to be 0.999. Compared with immunoradiometric assay (IRMA) kits, the correlative equation is y=1.07x+0.68, and correlation coefficient r=0.97. The standard range for the method is 1.5-80 μg/L, and it presents good linearity. (authors)

  2. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Bü chel, Gabriel E.; Carney, Brandon; Shaffer, Travis M.; Tang, Jun; Austin, Christine; Arora, Manish; Zeglis, Brian M.; Grimm, Jan; Eppinger, Jö rg; Reiner, Thomas

    2016-01-01

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Büchel, Gabriel E.

    2016-08-03

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A Novel Technique for Generating and Observing Chemiluminescence in a Biological Setting

    KAUST Repository

    Bü chel, Gabriel E.; Carney, Brandon; Tang, Jun; Zeglis, Brian M.; Eppinger, Jö rg; Reiner, Thomas

    2017-01-01

    not yet explored for intraoperative imaging: chemiluminescent imaging. This method employs a ruthenium-based chemiluminescent reporter along with a custom-built nebulizing system to produce ex vivo or in vivo images with high signal-to-noise ratios

  5. Nanoparticle-based immunosensor with apoferritin templated metallic phosphate label for quantification of phosphorylated acetylcholinesterase

    Energy Technology Data Exchange (ETDEWEB)

    Du, Dan; Chen, Aiqiong; Xie, Yunying; Zhang, Aidong; Lin, Yuehe

    2011-05-15

    A new sandwich-like electrochemical immunosensor has been developed for quantification of organophosphorylated acetylcholinesterase (OP-AChE), an exposure biomarker of organophosphate pesticides and nerve agents. Zirconia nanoparticles (ZrO2 NPs) were anchored on a screen printed electrode (SPE) to preferably capture OP-AChE adducts by metal chelation with phospho-moieties, which was selectively recognized by lead phosphate-apoferritin labeled anti-AChE antibody (LPA-anti-AChE). The sandwich-like immunoreactions were performed among ZrO2 NPs, OP-AChE and LPA-anti-AChE to form ZrO2/OP-AChE/LPA-anti-AChE complex and the released lead ions were detected on a disposable SPE. The binding affinity was investigated by both square wave voltammetry (SWV) and quartz crystal microbalance (QCM) measurements. The proposed immunosensor yielded a linear response current over a broad OP-AChE concentrations range from 0.05 nM to 10 nM, with detection limit of 0.02 nM, which has enough sensitivity for monitoring of low-dose exposure to OPs. This method avoids the drawback of unavailability of commercial OP-specific antibody as well as amplifies detection signal by using apoferritin encoded metallic phosphate nanoparticle tags. This nanoparticle-based immunosensor offers a new method for rapid, sensitive, selective and inexpensive quantification of phosphorylated adducts for monitoring of OP pesticides and nerve agents exposures.

  6. Nanoparticle-based immunosensor with apoferritin templated metallic phosphate label for quantification of phosphorylated acetylcholinesterase

    International Nuclear Information System (INIS)

    Du, Dan; Chen, Aiqiong; Xie, Yunying; Zhang, Aidong; Lin, Yuehe

    2011-01-01

    A new sandwich-like electrochemical immunosensor has been developed for quantification of organophosphorylated acetylcholinesterase (OP-AChE), an exposure biomarker of organophosphate pesticides and nerve agents. Zirconia nanoparticles (ZrO2 NPs) were anchored on a screen printed electrode (SPE) to preferably capture OP-AChE adducts by metal chelation with phospho-moieties, which was selectively recognized by lead phosphate-apoferritin labeled anti-AChE antibody (LPA-anti-AChE). The sandwich-like immunoreactions were performed among ZrO2 NPs, OP-AChE and LPA-anti-AChE to form ZrO2/OP-AChE/LPA-anti-AChE complex and the released lead ions were detected on a disposable SPE. The binding affinity was investigated by both square wave voltammetry (SWV) and quartz crystal microbalance (QCM) measurements. The proposed immunosensor yielded a linear response current over a broad OP-AChE concentrations range from 0.05 nM to 10 nM, with detection limit of 0.02 nM, which has enough sensitivity for monitoring of low-dose exposure to OPs. This method avoids the drawback of unavailability of commercial OP-specific antibody as well as amplifies detection signal by using apoferritin encoded metallic phosphate nanoparticle tags. This nanoparticle-based immunosensor offers a new method for rapid, sensitive, selective and inexpensive quantification of phosphorylated adducts for monitoring of OP pesticides and nerve agents exposures.

  7. Simple and suitable immunosensor for β-lactam antibiotics analysis in real matrixes: milk, serum, urine.

    Science.gov (United States)

    Merola, Giovanni; Martini, Elisabetta; Tomassetti, Mauro; Campanella, Luigi

    2015-03-15

    The anti-penicillin G was conjugated to avidin-peroxidase and biotin to obtain immunogen and competitor which were then used to develop a competitive immunosensor assay for the detection of penicillin G and other β-lactam antibiotics, with Kaff values of the order of 10(8) M(-1). The new immunosensor appears to afford a number of advantages in terms of sensitivity, possibility of "in situ" analysis, but especially of simplicity and lower costs, compared with other existing devices, or different chemical instrumental methods reported in the literature and used for the analysis of β-lactam compounds. Satisfactory results were found in the analysis of real matrixes and good recoveries were obtained by applying the standard addition method to spiked milk, urine, serum and drug samples. The new device uses an amperometric electrode for hydrogen peroxide as transducer, the BSA-penicillin G immobilized on polymeric membrane overlapping the amperometric transducer and the peroxidase enzyme as marker. It proved to be highly sensitive, inexpensive and easily reproducible; LOD was of the order of 10(-11)M. Lastly, the new immunosensor displayed low selectivity versus the entire class of β-lactam antibiotics and higher selectivity toward other classes of non-β-lactam antibiotics. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. FIBER OPTIC IMMUNOSENSORS BASED ON ENHANCED CHEMILUMINESCENCE AND THEIR APPLICATION TO DETERMINE DIFFERENT ANTIGENS

    NARCIS (Netherlands)

    STARODUB, NF; ARENKOV, PJ; STARODUB, AN; BEREZIN, VA

    The main scheme of the cell for measuring as well as the sensor device itself, the analysis conditions and the results of quantitative determination of several antigens such as estradiol-17, alpha-2-interferon, chorionic honadotropine, antibodies to the influenza virus, total IgG and cells of

  9. FET immunosensor for hemoglobin A1c using a gold nanofilm grown by a seed-mediated technique and covered with mixed self-assembled monolayers

    International Nuclear Information System (INIS)

    Xue, Q.; Bian, C.; Tong, J.; Sun, J.; Zhang, H.; Xia, S.

    2012-01-01

    A micro FET-based immunosensor was developed for the determination of hemoglobin-A1c (HbA1c). The HbA1c/hemoglobin ratio is an important index in diabetes control. The sensor was fabricated by Complementary Metal-Oxide-Semiconductor Transistor (CMOS) and Micro Electronic Mechanical System (MEMS) techniques. The antibodies were immobilized via mixed self-assembled monolayers (SAMs) on a gold nanofilm. The nanofilm was deposited on a gold electrode by seed-mediated growth and gave a uniform and well distributed coverage. Nonspecific sites and interferences by noise were eliminated by covering the AuNPs with mixed SAMs. Compared to the immunosensor fabricated via the mixed SAMs method without gold nanofilm, the immunosensor displays a more than 2-fold sensitivity. The immunosensor is capable of detecting HbA1c and hemoglobin in hemolyzed and diluted whole blood, and results showed good agreement with the established clinical method. (author)

  10. 3D-printed and CNC milled flow-cells for chemiluminescence detection.

    Science.gov (United States)

    Spilstead, Kara B; Learey, Jessica J; Doeven, Egan H; Barbante, Gregory J; Mohr, Stephan; Barnett, Neil W; Terry, Jessica M; Hall, Robynne M; Francis, Paul S

    2014-08-01

    Herein we explore modern fabrication techniques for the development of chemiluminescence detection flow-cells with features not attainable using the traditional coiled tubing approach. This includes the first 3D-printed chemiluminescence flow-cells, and a milled flow-cell designed to split the analyte stream into two separate detection zones within the same polymer chip. The flow-cells are compared to conventional detection systems using flow injection analysis (FIA) and high performance liquid chromatography (HPLC), with the fast chemiluminescence reactions of an acidic potassium permanganate reagent with morphine and a series of adrenergic phenolic amines. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Chemiluminescence. Principles and applications in biology and medicine

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, A K

    1988-01-01

    Chemiluminescence, the emission of light caused by a chemical reaction, is a phenomenon used for many applications and of wide biological importance. It occurs in bacteria and insects (including glow-worms and fireflies), in many of the animals in the deep sea and even in human cells. The last 25 years have witnessed fast progress in the elucidation of the reactions and mechanisms underlying bioluminescence and light production by synthetic systems. Together with the development of highly sensitive light detectors, this has made available new biomedical methods and has given rise to new concepts concerning the biology and pathology of the cell. The book describes the occurrence, chemistry and measurement of chemiluminescence. It deals with the biological function and evolutionary significance, and looks at the many biomedical applications. The author describes the uses of chemiluminescence to measure enzymes, substrates and metabolites, to detect the changes of calcium concentration in living cells, to determine oxygen radicals or to replace the radioactive labels in immunoassays. Future applications in research and clinical laboratories are also discussed.

  12. A chemiluminescent method for determination of lipid peroxidation

    International Nuclear Information System (INIS)

    Liang Xiaofeng; Hu Tianxi; Fan Xiaobing

    2003-01-01

    We established a chemiluminescent system for determination of lipid peroxidation and screening anti-oxidants. The lipid containing unsaturated fatly acids was injected into a galls tube. Luminol solution and the deionized water were added into it too. The glass tube was put into a preincubation box to incubate it for 0.5 h at 37 degree C. AAPH solution was injected into the tube for immediate measurement in a biochemiluminometer at 38-39 degree C. The pulses /6s(CP6s) were determined with T-2 program. Chemiluminescent dynamic and lipid peroxidation changes were observed continuously. Once the CL intensity of lipid peroxidation got peak, the antioxidant which has different concentration was added immediately in situ. A certain CL intensity (CP6s) was chosen as evaluation index to compare the activity of antioxidants. A luminol chemiluminescent system for determination of lipid peroxidation has been made. It was found that Vit. C, teapolyphenol, and glutathione have effects on scavenging lipid free radicals. The new method is quick, sensitive, and simple for determination of lipid peroxidation and screening antioxidants

  13. A dual amplified electrochemical immunosensor for ofloxacin: Polypyrrole film-Au nanocluster as the matrix and multi-enzyme-antibody functionalized gold nanorod as the label

    International Nuclear Information System (INIS)

    Zang, Shuai; Liu, Yingju; Lin, Mouhong; Kang, Jianli; Sun, Yuanming; Lei, Hongtao

    2013-01-01

    Graphical abstract: Schematic representation of the OFL electrochemical immunosensor using Au nanoclusters/PPy/GCE as the substrate and multi-HRP-GNR-Ab2 bioconjugates as the label. Highlights: ► Gold nanorod was used to load HRP and Ab 2 to form multi-HRP-GNR-Ab 2 . ► A sensitive immunosensor for ofloxacin was constructed using the homemade antibody. ► A dual signal amplified strategy was based on the PPy-Au and multi-HRP-GNR-Ab 2 . -- Abstract: In this work, an electrochemical immunosensor, basing on a dual signal amplified strategy by employing a biocompatible polypyrrole film-Au nanocluster matrix as a sensor platform and multi-enzyme-antibody functionalized gold nanorod as an electrochemical detection label, is established for sensitive detection of ofloxacin (OFL). Firstly, polypyrrole film and Au nanoclusters were progressively fabricated onto the surface of a glassy carbon electrode via electropolymerization and electrochemical deposition, respectively. Such PPy-Au nanocomposite modified electrode was used to immobilize OFL-OVA, blocked with the blocking reagent, and then associated with the corresponding antibody. Secondly, gold nanorod (GNR) was synthesized to load horseradish peroxidase (HRP) and horseradish peroxidase-secondary antibody (HRP-Ab 2 ), and the resulting nanostructure (multi-HRP-GNR-Ab 2 ) was applied as the detection label. The fabrication process of the ordered multilayer structure and immunosensor were characterized by scanning electron microscopy (SEM) and electrochemical measurements, respectively. Finally, based on a competitive immunoassay, i.e., the association ability with the corresponding antibody between the captured antigen and free OFL in the solution, the fabricated immunosensor exhibited a sensitive response to OFL in the range from 0.08 to 410 ng/mL with a detection limit of 0.03 ng/mL. The current immunosensor exhibited good sensitivity, selectivity and long-term stability. This amplification strategy shows excellent

  14. Feasibility of evanescent wave interferometer immunosensors for pesticide detection: chemical aspects

    NARCIS (Netherlands)

    Lechuga, L.M.; Lechuga, L.M.; Lenferink, Aufrid T.M.; Kooyman, R.P.H.; Greve, Jan

    1995-01-01

    A waveguide Mach-Zehnder Interferometer (MZI) immunosensor has been developed which can detect, in a direct way, a minimum average layer growth thickness of the analyte of 2×10−3 nm (bound mass, I′=1×10−4 δ cm−2). The design and fabrication of the sensor and the experimental set-up are aimed at

  15. Carbon nanotubes-based chemiresistive immunosensor for small molecules: detection of nitroaromatic explosives.

    Science.gov (United States)

    Park, Miso; Cella, Lakshmi N; Chen, Wilfred; Myung, Nosang V; Mulchandani, Ashok

    2010-12-15

    In recent years, there has been a growing focus on use of one-dimensional (1-D) nanostructures, such as carbon nanotubes and nanowires, as transducer elements for label-free chemiresistive/field-effect transistor biosensors as they provide label-free and high sensitivity detection. While research to-date has elucidated the power of carbon nanotubes- and other 1-D nanostructure-based field effect transistors immunosensors for large charged macromolecules such as proteins and viruses, their application to small uncharged or charged molecules has not been demonstrated. In this paper we report a single-walled carbon nanotubes (SWNTs)-based chemiresistive immunosensor for label-free, rapid, sensitive and selective detection of 2,4,6-trinitrotoluene (TNT), a small molecule. The newly developed immunosensor employed a displacement mode/format in which SWNTs network forming conduction channel of the sensor was first modified with trinitrophenyl (TNP), an analog of TNT, and then ligated with the anti-TNP single chain antibody. Upon exposure to TNT or its derivatives the bound antibodies were displaced producing a large change, several folds higher than the noise, in the resistance/conductance of SWNTs giving excellent limit of detection, sensitivity and selectivity. The sensor detected between 0.5 ppb and 5000 ppb TNT with good selectivity to other nitroaromatic explosives and demonstrated good accuracy for monitoring TNT in untreated environmental water matrix. We believe this new displacement format can be easily generalized to other one-dimensional nanostructure-based chemiresistive immuno/affinity-sensors for detecting small and/or uncharged molecules of interest in environmental monitoring and health care. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Biological water quality monitoring using chemiluminescent and bioluminescent techniques

    Science.gov (United States)

    Thomas, R. R.

    1978-01-01

    Automated chemiluminescence and bioluminescence sensors were developed for the continuous monitoring of microbial levels in water supplies. The optimal chemical procedures were determined for the chemiluminescence system to achieve maximum sensitivity. By using hydrogen peroxide, reaction rate differentiation, ethylene diamine tetraacetic acid (EDTA), and carbon monoxide pretreatments, factors which cause interference were eliminated and specificity of the reaction for living and dead bacteria was greatly increased. By employing existing technology with some modifications, a sensitive and specific bioluminescent system was developed.

  17. A novel photoelectrochemical immunosensor by integration of nanobody and TiO2 nanotubes for sensitive detection of serum cystatin C

    International Nuclear Information System (INIS)

    Mi, Li; Wang, Pingyan; Yan, Junrong; Qian, Jing; Lu, Jusheng; Yu, Jiachao; Wang, Yuzhen; Liu, Hong; Zhu, Min; Wan, Yakun; Liu, Songqin

    2016-01-01

    Cystatin C (CysC) is a sensitive marker for the estimation of the glomerular filtration rate and the clinical diagnosis of different diseases. In this paper, CysC-specific nanobodies (Nbs) were isolated from a phage display nanobody library. A simple and sensitive photoelectrochemical immunosensor based on TiO 2 nanotube arrays (TNAs) was proposed for the sensitive detection of CysC. The TiO 2 nanotube arrays deposited by electrochemical anodization displayed a high and stable photocurrent response under irradiation. After coupling CysC-specific nanobody to TNA (Nb/TNA), the proposed immunosensor for CysC can be utilized for tracking the photocurrent change of Nb/TNA caused by immunoreactions between CysC and the immobilized CysC-specific Nb. This allowed for the determination of CysC with a calibration range from 0.72 pM to 7.19 nM. The variation of the photocurrent was in a linear relationship with the logarithm of the CysC concentration in the range of 0.72 pM–3.6 nM. The immunosensor had a correlation coefficient of 0.97 and a detection limit of 0.14 pM at a signal-to-noise ratio of 3. The proposed immunosensor showed satisfactory intra- and inter-assay accuracy, high selectivity and good stability. As a result, this proposed strategy would offer a novel and simple approach for the detection of immunoreactions, provide new insights in popularizing the diagnosis of CysC, and extend the application of TiO 2 nanotubes. - Highlights: • CysC-specific nanobody to CysC is isolated from phage display nanobody library. • A photoelectrochemical immunosensor for CysC develops by Nb modified TNA. • An excellent sensitivity and good selectivity of CysC sensing was obtained.

  18. Electrochemical immunosensor with NiAl-layered double hydroxide/graphene nanocomposites and hollow gold nanospheres double-assisted signal amplification.

    Science.gov (United States)

    Qiao, Lu; Guo, Yemin; Sun, Xia; Jiao, Yancui; Wang, Xiangyou

    2015-08-01

    A sensitive electrochemical immunosensor based on NiAl-layered double hydroxide/graphene nanocomposites (NiAl-LDH/G) and hollow gold nanospheres (HGNs) was proposed for chlorpyrifos detection. The NiAl-LDH/G was prepared using a conventional coprecipitation process and reduction of the supporting graphene oxide. Subsequently, the nanocomposites were dispersed with chitosan (CS). The NiAl-LDH/G possessed good electrochemical behavior and high binding affinity to the electrode. The high surface areas of HGNs and the vast aminos and hydroxyls of CS provided a platform for the covalently crosslinking of antibody. Under optimal conditions, the immunosensor exhibited a wide linear range from 5 to 150 μg/mL and from 150 to 2 μg/mL, with a detection limit of 0.052 ng/mL. The detection results showed good agreement with standard gas chromatography method. The constructed immunosensor exhibited good reproducibility, high specificity, acceptable stability and regeneration performance, which provided a new promising tool for chlorpyrifos detection in real samples.

  19. Flow-injection chemiluminescence assay for ultra-trace determination of DNA using rhodamine B-Ce(IV)-DNA ternary system in sulfuric acid media

    International Nuclear Information System (INIS)

    Ma Yongjun; Zhou Min; Jin Xiaoyong; Zhang Ziyu; Teng Xiulan; Chen Hui

    2004-01-01

    A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0x10 -8 to 0.1 μg ml -1 for herring sperm DNA and 2.0x10 -6 to 0.2 μg ml -1 for calf thymus DNA with 3σ detection limits of 8.3x10 -9 μg ml -1 for herring sperm DNA and 3.5x10 -7 μg ml -1 for calf thymus DNA, respectively. The relative standard deviation for 1.0x10 -4 μg ml -1 herring sperm DNA was 0.99% and 2.0x10 -3 μg ml -1 for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper

  20. Flow-injection chemiluminescence assay for ultra-trace determination of DNA using rhodamine B-Ce(IV)-DNA ternary system in sulfuric acid media

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yongjun; Zhou Min; Jin Xiaoyong; Zhang Ziyu; Teng Xiulan; Chen Hui

    2004-01-09

    A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0x10{sup -8} to 0.1 {mu}g ml{sup -1} for herring sperm DNA and 2.0x10{sup -6} to 0.2 {mu}g ml{sup -1} for calf thymus DNA with 3{sigma} detection limits of 8.3x10{sup -9} {mu}g ml{sup -1} for herring sperm DNA and 3.5x10{sup -7} {mu}g ml{sup -1} for calf thymus DNA, respectively. The relative standard deviation for 1.0x10{sup -4} {mu}g ml{sup -1} herring sperm DNA was 0.99% and 2.0x10{sup -3} {mu}g ml{sup -1} for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper.

  1. Nanostructured progesterone immunosensor using a tyrosinase-colloidal gold-graphite-Teflon biosensor as amperometric transducer

    International Nuclear Information System (INIS)

    Carralero, Veronica; Gonzalez-Cortes, Araceli; Yanez-Sedeno, Paloma; Pingarron, Jose M.

    2007-01-01

    A novel progesterone immunosensor using a colloidal gold-graphite-Teflon-tyrosinase composite biosensor as amperometric transducer is reported. A sequential competitive configuration between the analyte and progesterone labelled with alkaline phosphatase (AP) was used. Phenyl phosphate was employed as the AP-substrate and the enzyme reaction product, phenol, was oxidized by tyrosinase to o-quinone, which is subsequently reduced at -0.1 V at the biocomposite electrode. Variables such as the concentration of phenyl phosphate, the amount of antibody attached to the electrode surface, immersion time in a 2% BSA solution, working pH and incubation times in progesterone and AP conjugate were optimized. A linear calibration graph for progesterone was obtained between 0 and 40 ng mL -1 with a slope value of -82.3 nA ng -1 mL, and a detection limit of 0.43 ng mL -1 . The time needed to reach the steady-state current from the addition of phenyl phosphate was 30-40 s. These analytical characteristics improve substantially those reported for other progesterone immunosensors. A lifetime of 14 days with no need to apply any regeneration procedure was also achieved. The usefulness of the immunosensor was evaluated by determining progesterone in milk samples spiked with the analyte at 5.0 and 1.5 ng mL -1 concentration levels. Following a very simple procedure, involving only sample dilution, mean recoveries (n = 7) of 98 ± 3% and 99 ± 3%, respectively, were obtained

  2. Nanostructured progesterone immunosensor using a tyrosinase-colloidal gold-graphite-Teflon biosensor as amperometric transducer

    Energy Technology Data Exchange (ETDEWEB)

    Carralero, Veronica [Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, 28040 Madrid (Spain); Gonzalez-Cortes, Araceli [Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, 28040 Madrid (Spain); Yanez-Sedeno, Paloma [Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, 28040 Madrid (Spain)]. E-mail: yseo@quim.ucm.es; Pingarron, Jose M. [Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, 28040 Madrid (Spain)

    2007-07-16

    A novel progesterone immunosensor using a colloidal gold-graphite-Teflon-tyrosinase composite biosensor as amperometric transducer is reported. A sequential competitive configuration between the analyte and progesterone labelled with alkaline phosphatase (AP) was used. Phenyl phosphate was employed as the AP-substrate and the enzyme reaction product, phenol, was oxidized by tyrosinase to o-quinone, which is subsequently reduced at -0.1 V at the biocomposite electrode. Variables such as the concentration of phenyl phosphate, the amount of antibody attached to the electrode surface, immersion time in a 2% BSA solution, working pH and incubation times in progesterone and AP conjugate were optimized. A linear calibration graph for progesterone was obtained between 0 and 40 ng mL{sup -1} with a slope value of -82.3 nA ng{sup -1} mL, and a detection limit of 0.43 ng mL{sup -1}. The time needed to reach the steady-state current from the addition of phenyl phosphate was 30-40 s. These analytical characteristics improve substantially those reported for other progesterone immunosensors. A lifetime of 14 days with no need to apply any regeneration procedure was also achieved. The usefulness of the immunosensor was evaluated by determining progesterone in milk samples spiked with the analyte at 5.0 and 1.5 ng mL{sup -1} concentration levels. Following a very simple procedure, involving only sample dilution, mean recoveries (n = 7) of 98 {+-} 3% and 99 {+-} 3%, respectively, were obtained.

  3. Chemiluminescence determination of ultramicro DNA with a flow-injection method

    International Nuclear Information System (INIS)

    Chen Hui; Zhou Min; Jin Xiaoyong; Song Yumin; Zhang Ziyu; Ma Yongjun

    2002-01-01

    A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6x10 -5 to 0.26 μg ml -1 for calf thymus DNA and 5.0x10 -8 to 5.0x10 -5 μg ml -1 for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3σ) are 6.5x10 -6 μg ml -1 for calf thymus DNA and 4.3x10 -8 μg ml -1 for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed

  4. Facile preparation of disposable immunosensor for Shigella flexneri based on multi-wall carbon nanotubes/chitosan composite

    International Nuclear Information System (INIS)

    Zhao Guangying; Zhan Xuejia

    2010-01-01

    Based on multi-wall carbon nanotubes (MWCNT)/chitosan/horseradish peroxidase labeled antibodies to Shigella flexneri (HRP-anti-S. flexneri) biocomposite film on a screen-printed electrode (SPE) surface, a disposable immunosensor has been developed for the rapid detection of S. flexneri. The HRP-anti-S. flexneri can be entrapped into MWCNT/chitosan composite matrix without other cross-linking agent. Thionine and H 2 O 2 were used as the mediator and substrate, respectively. The surface morphologies of modified films were characterized by atomic force microscope (AFM). Cyclic voltammery (CV) was carried out to characterize the electrochemical properties of the immobilization of materials on the electrode surface and quantified S. flexneri. Due to the strong electrocatalytic properties of MWCNT and HRP toward H 2 O 2 , the response signal was significantly amplified. S. flexneri could be detected by the decrease of the reduction peak current before and after immunoreaction. Under optimal conditions, S. flexneri could be detected in the range of 10 4 to 10 10 cfu mL -1 , with a detection limit of 2.3 x 10 3 cfu mL -1 (S/N = 3). Furthermore, the proposed immunosensor exhibited a satisfactory specificity, reproducibility, stability and accuracy, indicating that the proposed immunosensor has potential application for a facile, rapid and harmless immunoassay.

  5. Design, fabrication and characterization of a two-step released silicon dioxide piezoresistive microcantilever immunosensor

    International Nuclear Information System (INIS)

    Zhou, Youzheng; Wang, Zheyao; Wang, Chaonan; Ruan, Wenzhou; Liu, Litian

    2009-01-01

    This paper presents the design, fabrication and characterization of a silicon dioxide piezoresistive microcantilever immunosensor fabricated on silicon-on-insulator (SOI) wafers. The microcantilever consists of two strips of single crystalline silicon piezoresistors sandwiched in between two silicon dioxide layers. A theoretical model for the laminated microcantilever with a discontinuous layer is deduced using classic laminated beam theory. A two-step release method combining anisotropic and isotropic etching is developed to suspend the microcantilever, and the fabrication results show an excellent yield. The residual stress-induced free bending of the microcantilever and the stress caused by self-heating of the piezoresistors are discussed. The microcantilever sensor is characterized as an immunosensor using specific binding of antigen and antibody. These methods and some conclusions are also applicable to the development of other piezoresistive sensors that use laminated structures

  6. Determination of hyperin in seed of Cuscuta chinensis Lam. by enhanced chemiluminescence of CdTe quantum dots on calcein/K3Fe(CN)6 system.

    Science.gov (United States)

    Kang, Jing; Li, Xuwen; Geng, Jiayang; Han, Lu; Tang, Jieli; Jin, Yongri; Zhang, Yihua

    2012-10-15

    In this paper, 3-mercaptocarboxylic acid (MPA) modified CdTe quantum dots (QDs) were used as sensitizers, to enhance the chemiluminescence (CL) of the calcein/K(3)Fe(CN)(6) system. A new CL system of CdTe/calcein/K(3)Fe(CN)(6) was developed. The effects of reactant concentrations and the particle sizes of CdTe QDs on the CL emission were investigated in detail. The possible enhancement mechanism of the CL was also further investigated based on the photoluminescence (PL) and CL spectra. Polyphenols such as chlorogenic acid, quercetin, hyperin, catechin and kaempferol, were observed to inhibit the CL signal of the CdTe/calcein/K(3)Fe(CN)(6) system and determined by the proposed method. The proposed method was applied to the determination of hyperin in seed of Cuscuta chinensis Lam. and the results obtained were satisfactory. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Electrochemical immunosensor assay (EIA) for sensitive detection of E. coli O157:H7 with signal amplification on a SG-PEDOT-AuNPs electrode interface.

    Science.gov (United States)

    Guo, Yuna; Wang, Yu; Liu, Su; Yu, Jinghua; Wang, Hongzhi; Cui, Min; Huang, Jiadong

    2015-01-21

    A novel electrochemical immunosensor assay (EIA) for highly sensitive and specific detection of Escherichia coli O157:H7 has been developed. This immunosensor is constructed by the assembly of capture antibody on SG-PEDOT-AuNPs composites modified glass carbon electrode. In the presence of target E. coli O157:H7, horseradish peroxidase (HRP)-labeled antibody is captured on the electrode surface to form a sandwich-type system via the specific identification. As a result, E. coli O157:H7 detection is realized by outputting a redox current from electro-reduction of hydrogen peroxide reaction catalyzed by HRP. In our assay, the combination of the unique properties of sulfonated graphene (SG) and gold nanoparticles (AuNPs) can not only accelerate electron transfer on electrode interface, but also provide an excellent scaffold for the conjugation of capture antibody that significantly improves the target capture efficiency and enhances the sensitivity of the biosensor. The results reveal the calibration plot obtained for E. coli O157:H7 is approximately linear from 7.8 × 10-7.8 × 10(6) colony-forming unit (cfu) mL(-1) with the limit of detection of 3.4 × 10 cfu mL(-1). In addition, the biosensor has been successfully applied to the quantitative assay of E. coli O157:H7 in synthetic samples (spring water and milk). Hence, the developed electrochemical-based immunosensor might provide a useful and practical tool for E. coli O157:H7 determination and related food safety analysis and clinical diagnosis.

  8. Determination of cyanide using a chemiluminescence system composed of permanganate, rhodamine B, and gold nanoparticles

    International Nuclear Information System (INIS)

    Amjadi, Mohammad; Hassanzadeh, Javad; Manzoori, Jamshid L.

    2014-01-01

    We describe a new chemiluminescence (CL) system based on the oxidation of rhodamine B (RhoB) with alkaline potassium permanganate in the presence of gold nanoparticles (Au-NPs) and anionic detergent sodium dodecyl sulfate. Free RhoB is weakly chemiluminescent when oxidized with permanganate at alkaline pH values. However, a remarkably strong enhancement of CL is observed in the presence of Au-NPs, probably due to a strong interaction between RhoB and the NPs. The possible mechanism was studied via recording the CL emission. It is also found that the intensity of CL gradually decreases in the presence of cyanide due to its interaction with the Au-NPs. The relation between the decreased CL intensity and cyanide concentration was exploited to develop a method for the determination of cyanide in the 0.01–0.5 μM concentration range, with a detection limit of 2.8 nM. The method was used to determine cyanide in spiked water, urine, and serum. (author)

  9. Long-term chemiluminescence signal is produced in the course of luminol oxidation catalyzed by enhancer-independent peroxidase purified from Jatropha curcas leaves.

    Science.gov (United States)

    Duan, Peipei; Cai, Feng; Luo, Yongting; Chen, Yangxi; Zou, Shujuan

    2015-09-01

    Isoenzyme c of horseradish peroxidase (HRP-C) is widely used in enzyme immunoassay combined with chemiluminescence (CL) detection. For this application, HRP-C activity measurement is usually based on luminol oxidation in the presence of hydrogen peroxide (H2O2). However, this catalysis reaction was enhancer dependent. In this study, we demonstrated that Jatropha curcas peroxidase (JcGP1) showed high efficiency in catalyzing luminol oxidation in the presence of H2O2. Compared with HRP-C, the JcGP1-induced reaction was enhancer independent, which made the enzyme-linked immunosorbent assay (ELISA) simpler. In addition, the JcGP1 catalyzed reaction showed a long-term stable CL signal. We optimized the conditions for JcGP1 catalysis and determined the favorable conditions as follows: 50 mM Tris buffer (pH 8.2) containing 10 mM H2 O2, 14 mM luminol and 0.75 M NaCl. The optimum catalysis temperature was 30°C. The detection limit of JcGP1 under optimum condition was 0.2 pM. Long-term stable CL signal combined with enhancer-independent property indicated that JcGP1 might be a valuable candidate peroxidase for clinical diagnosis and enzyme immunoassay with CL detection. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Imaging and high-sensitivity quantification of chemiluminescent labeled DNA-blots

    International Nuclear Information System (INIS)

    Dorner, G.

    1997-01-01

    The present thesis has for objective the development of both, methods of DNA labeling by chemiluminescence (via the catalytic activity of the enzyme alkaline phosphatase - AP) and an appropriate imaging system. Offering a competitive alternative to the detection of classical radio-labels in molecular-biological experiments of the blotting type, this technique should permit the realization of quantitative studies of gene expression at ultra-high sensitivity necessary in particular for differential-screening experiments. To reach our aim. we separated the project into three different parts. In a first step an imager based on a liquid-nitrogen-cooled CCD coupled to a standard optics (50 mm/fl.2) has been installed and characterized. This system offers a sensitive area of up to 625 cm 2 , a spatial resolution of 0.3-1 mm (depending on the field of view) and a sensitivity sufficient to detect 10 fg/mm 2 labeled DNA. In a second part, the chemiluminescent light-generation process in solution has been investigated to optimize the parameters temperature. pH and concentration of the substrate as well as the enzyme. The substrate offering the highest light yield (CDP-Star in addition with the enhancer EMERALD II) allows quantification of AP down to 10 -15 M within a dynamic range of 10 4 in solution. Finally. preparation, immobilization and detection of AP-labeled DNA probes (via a biotin-streptavidin-biotin-AP bridge) on nylon membranes has been optimized. A linear relation between the light intensities and the amount of DNA was observed in a range of 10 fg/mm 2 - 100 pg/mm 2 . Hybridization of the probes to bacterial cloned target-DNA has been addressed after examination of the best hybridization conditions. Our protocol includes the treatment of a proteinase, which resulted in a significantly lower background on the filter. The results of our investigations suggest that the main conditions for a reliable differential-screening experiment are fulfilled when using

  11. Chemiluminescence determination of ultramicro DNA with a flow-injection method

    Energy Technology Data Exchange (ETDEWEB)

    Chen Hui; Zhou Min; Jin Xiaoyong; Song Yumin; Zhang Ziyu; Ma Yongjun

    2002-02-12

    A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6x10{sup -5} to 0.26 {mu}g ml{sup -1} for calf thymus DNA and 5.0x10{sup -8} to 5.0x10{sup -5} {mu}g ml{sup -1} for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3{sigma}) are 6.5x10{sup -6} {mu}g ml{sup -1} for calf thymus DNA and 4.3x10{sup -8} {mu}g ml{sup -1} for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed.

  12. Core–shell Fe3O4–Au magnetic nanoparticles based nonenzymatic ultrasensitive electrochemiluminescence immunosensor using quantum dots functionalized graphene sheet as labels

    International Nuclear Information System (INIS)

    Liu, Weiyan; Zhang, Yan; Ge, Shenguang; Song, Xianrang; Huang, Jiadong; Yan, Mei; Yu, Jinghua

    2013-01-01

    Graphical abstract: Core–shell Fe 3 O 4 –Au magnetic nanoparticles and P-GS@QDs were prepared to immobilize Ab 1 and Ab 2 respectively and combined to fabricate a novel sandwich-type ECL immunosensor for detecting CA125 at low concentration. Highlights: ► ECL immunosensor for CA125 based on a microfluidic strategy with a homemade ECL cell was proposed. ► Core–shell Fe 3 O 4 –Au magnetic nanoparticles were employed as the carriers of the primary antibodies. ► CdTe quantum dots functionalized graphene sheet were used for signal amplification. -- Abstract: In this paper, a novel, low-cost electrochemiluminescence (ECL) immunosensor using core–shell Fe 3 O 4 –Au magnetic nanoparticles (AuMNPs) as the carriers of the primary antibody of carbohydrate antigen 125 (CA125) was designed. Graphene sheet (GS) with property of good conductivity and large surface area was a captivating candidate to amplify ECL signal. We successively synthesized functionalized GS by loading large amounts of quantum dots (QDs) onto the poly (diallyldimethyl-ammonium chloride) (PDDA) coated graphene sheet (P-GS@QDs) via self-assembly electrostatic reactions, which were used to label secondary antibodies. The ECL immunosensors coupled with a microfluidic strategy exhibited a wide detection range (0.005–50 U mL −1 ) and a low detection limit (1.2 mU mL −1 ) with the help of an external magnetic field to gather immunosensors. The method was evaluated with clinical serum sample, receiving good correlation with results from commercially available analytical procedure

  13. A novel photoelectrochemical immunosensor by integration of nanobody and TiO{sub 2} nanotubes for sensitive detection of serum cystatin C

    Energy Technology Data Exchange (ETDEWEB)

    Mi, Li [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China); Wang, Pingyan; Yan, Junrong [Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203 (China); Qian, Jing; Lu, Jusheng; Yu, Jiachao [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China); Wang, Yuzhen; Liu, Hong [Plexera LLC, WA 98072 (United States); Zhu, Min [Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203 (China); Wan, Yakun, E-mail: ywansystemsbiology@gmail.com [Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203 (China); Jiangsu Nanobody Engineering and Research Center, Nantong 226010 (China); Liu, Songqin, E-mail: liusq@seu.edu.cn [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China)

    2016-01-01

    Cystatin C (CysC) is a sensitive marker for the estimation of the glomerular filtration rate and the clinical diagnosis of different diseases. In this paper, CysC-specific nanobodies (Nbs) were isolated from a phage display nanobody library. A simple and sensitive photoelectrochemical immunosensor based on TiO{sub 2} nanotube arrays (TNAs) was proposed for the sensitive detection of CysC. The TiO{sub 2} nanotube arrays deposited by electrochemical anodization displayed a high and stable photocurrent response under irradiation. After coupling CysC-specific nanobody to TNA (Nb/TNA), the proposed immunosensor for CysC can be utilized for tracking the photocurrent change of Nb/TNA caused by immunoreactions between CysC and the immobilized CysC-specific Nb. This allowed for the determination of CysC with a calibration range from 0.72 pM to 7.19 nM. The variation of the photocurrent was in a linear relationship with the logarithm of the CysC concentration in the range of 0.72 pM–3.6 nM. The immunosensor had a correlation coefficient of 0.97 and a detection limit of 0.14 pM at a signal-to-noise ratio of 3. The proposed immunosensor showed satisfactory intra- and inter-assay accuracy, high selectivity and good stability. As a result, this proposed strategy would offer a novel and simple approach for the detection of immunoreactions, provide new insights in popularizing the diagnosis of CysC, and extend the application of TiO{sub 2} nanotubes. - Highlights: • CysC-specific nanobody to CysC is isolated from phage display nanobody library. • A photoelectrochemical immunosensor for CysC develops by Nb modified TNA. • An excellent sensitivity and good selectivity of CysC sensing was obtained.

  14. Dendrimer-based biosensor for chemiluminescent detection of DNA hybridization

    International Nuclear Information System (INIS)

    Liu, P.; Hun, X.; Qing, H.

    2011-01-01

    We report on a highly sensitive chemiluminescent (CL) biosensor for the sequence-specific detection of DNA using a novel bio barcode DNA probe modified with gold nanoparticles that were covered with a dendrimer. The modified probe is composed of gold nanoparticles, a dendrimer, the CL reagent, and the DNA. The capture probe DNA was immobilized on magnetic beads covered with gold. It first hybridizes with the target DNA and then with one terminal end of the signal DNA on the barcoded DNA probe. CL was generated by adding H 2 O 2 and Co(II) ions as the catalyst. The immobilization of dendrimer onto the gold nanoparticles can significantly enhance sensitivity and gives a detection limit of 6 fmol L -1 of target DNA. (author)

  15. Large-scale synthesis of ultrathin Au-Pt nanowires assembled on thionine/graphene with high conductivity and sensitivity for electrochemical immunosensor

    International Nuclear Information System (INIS)

    Lu, Wenbo; Ge, Juan; Tao, Lin; Cao, Xiaowei; Dong, Jian; Qian, Weiping

    2014-01-01

    In this article, for the first time, a novel, label-free and inherent electroactive redox biosensor based on ultrathin Au-Pt nanowire-decorated thionine/reduced graphene oxide (AuPtNWs/THI/rGO) is developed for carcinoembryonic antigen (CEA) detection. Ultrathin AuPtNWs are prepared by a one-pot synthesis method without the use of any stabilizer or template. The AuPtNWs/THI/rGO composites are obtained by the THI/rGO composites surface functionalized with -NH 2 group employed as a support for loading ultrathin AuPtNWs by coordination. The AuPtNWs/THI/rGO composites not only favor the immobilization of antibody but also facilitate the electron transfer. It is found that the resultant AuPtNWs/THI/rGO composites can be designed to act as a sensitive label-free electrochemical immunosensor for CEA determination. Under the optimized conditions, the linear range of the proposed immunosensor is estimated to be from 50 fg·mL −1 to 100 ng·mL −1 (R= 0.998) and the detection limit is estimated to be 6 fg·mL −1 at a signal-to-noise ratio of 3, respectively. The prepared immunosensor for detection of CEA shows high sensitivity, reproducibility and stability. Our study demonstrates that the proposed immunosensor has also been used to determine CEA successfully in diluted blood samples

  16. A novel photoelectrochemical immunosensor by integration of nanobody and ZnO nanorods for sensitive detection of nucleoside diphosphatase kinase-A

    International Nuclear Information System (INIS)

    Liu, Anran; Yin, Kaifei; Mi, Li; Ma, Mengyao; Liu, Yuanjian; Li, Ying; Wei, Wei; Zhang, Yuanjian; Liu, Songqin

    2017-01-01

    Nucleoside diphosphatase kinase A (NDPK-A) is a metastasis-suppressor protein and a biomarker that act on a wide range cancer cells to inhibit the potential metastasis. Herein, we present a simple photoelectrochemical immunosensor based on ZnO nanorod arrays for the sensitive detection of NDPK-A. The ZnO nanorod arrays cosensitized with CdS nanoparticles and Mn 2+ displayed a high and stable photocurrent response under irradiation. After anti-NPDK-A nanobodies were immobilized to the ZnO nanorod arrays, the proposed immunosensor can be utilized for detecting NPDK-A by monitoring the changes in the photocurrent signals of the electrode resulting from immunoreaction. Accordingly, the well-designed immunosensor exhibited a low limit of detection (LOD) of 0.3 pg mL −1 and a wide linear range from 0.5 pg mL −1 to 10 μg mL −1 . The R 2 of the regression curve is 0.99782. Meanwhile, the good stability, reproducibility and specificity of the resulting photoelectrochemical biosensor are demonstrated. In addition, the presented work would offer a novel and simple approach for the detection of immunoreactions and provide new insights in popularizing the diagnosis of NPDK-A. - Highlights: • A photoelectrochemical immunosensor based on ZnO NAs and NBs was fabricated. • Cosensitized structure of ZnO NAs, CdS and Mn improved the photocurrent response. • An excellent sensitivity and selectivity of NDPK-A detection was obtained.

  17. A novel photoelectrochemical immunosensor by integration of nanobody and TiO₂ nanotubes for sensitive detection of serum cystatin C.

    Science.gov (United States)

    Mi, Li; Wang, Pingyan; Yan, Junrong; Qian, Jing; Lu, Jusheng; Yu, Jiachao; Wang, Yuzhen; Liu, Hong; Zhu, Min; Wan, Yakun; Liu, Songqin

    2016-01-01

    Cystatin C (CysC) is a sensitive marker for the estimation of the glomerular filtration rate and the clinical diagnosis of different diseases. In this paper, CysC-specific nanobodies (Nbs) were isolated from a phage display nanobody library. A simple and sensitive photoelectrochemical immunosensor based on TiO2 nanotube arrays (TNAs) was proposed for the sensitive detection of CysC. The TiO2 nanotube arrays deposited by electrochemical anodization displayed a high and stable photocurrent response under irradiation. After coupling CysC-specific nanobody to TNA (Nb/TNA), the proposed immunosensor for CysC can be utilized for tracking the photocurrent change of Nb/TNA caused by immunoreactions between CysC and the immobilized CysC-specific Nb. This allowed for the determination of CysC with a calibration range from 0.72 pM to 7.19 nM. The variation of the photocurrent was in a linear relationship with the logarithm of the CysC concentration in the range of 0.72 pM-3.6 nM. The immunosensor had a correlation coefficient of 0.97 and a detection limit of 0.14 pM at a signal-to-noise ratio of 3. The proposed immunosensor showed satisfactory intra- and inter-assay accuracy, high selectivity and good stability. As a result, this proposed strategy would offer a novel and simple approach for the detection of immunoreactions, provide new insights in popularizing the diagnosis of CysC, and extend the application of TiO2 nanotubes. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Determination of ethamsylate in pharmaceutical preparations based on an auto-oxidation chemiluminescence reaction.

    Science.gov (United States)

    Yang, Fengzhen; Zhang, Chao; Baeyens, Willy R G; Zhang, Xinrong

    2002-10-15

    Strong chemiluminescence emission has been observed by mixing alkaline hydrolytic products of ethamsylate with Tween 80 in acidic rhodamine 6G solution. This phenomenon has been utilized to design a flow-injection chemiluminescence method for the determination of ethamsylate in a pharmaceutical preparation. Under the optimum conditions, the proposed procedure has a linear range between 0.05 and 2.0 microg ml(-1), with a detection limit of 0.02 microg ml(-1) for ethamsylate. The method was applied to the determination of ethamsylate in pharmaceutical preparations. The possible mechanism of this chemiluminescence reaction was proposed. Copyright 2002 Elsevier Science B.V.

  19. Label free sensing of creatinine using a 6 GHz CMOS near-field dielectric immunosensor.

    Science.gov (United States)

    Guha, S; Warsinke, A; Tientcheu, Ch M; Schmalz, K; Meliani, C; Wenger, Ch

    2015-05-07

    In this work we present a CMOS high frequency direct immunosensor operating at 6 GHz (C-band) for label free determination of creatinine. The sensor is fabricated in standard 0.13 μm SiGe:C BiCMOS process. The report also demonstrates the ability to immobilize creatinine molecules on a Si3N4 passivation layer of the standard BiCMOS/CMOS process, therefore, evading any further need of cumbersome post processing of the fabricated sensor chip. The sensor is based on capacitive detection of the amount of non-creatinine bound antibodies binding to an immobilized creatinine layer on the passivated sensor. The chip bound antibody amount in turn corresponds indirectly to the creatinine concentration used in the incubation phase. The determination of creatinine in the concentration range of 0.88-880 μM is successfully demonstrated in this work. A sensitivity of 35 MHz/10 fold increase in creatinine concentration (during incubation) at the centre frequency of 6 GHz is gained by the immunosensor. The results are compared with a standard optical measurement technique and the dynamic range and sensitivity is of the order of the established optical indication technique. The C-band immunosensor chip comprising an area of 0.3 mm(2) reduces the sensing area considerably, therefore, requiring a sample volume as low as 2 μl. The small analyte sample volume and label free approach also reduce the experimental costs in addition to the low fabrication costs offered by the batch fabrication technique of CMOS/BiCMOS process.

  20. Amperometric Immunosensor Based on a Protein A/Deposited Gold Nanocrystals Modified Electrode for Carbofuran Detection

    Directory of Open Access Journals (Sweden)

    Xia Sun

    2011-12-01

    Full Text Available In this paper, an amperometric immunosensor modified with protein A/deposited gold nanocrystals (DpAu was developed for the ultrasensitive detection of carbofuran residues. First, DpAu were electrodeposited onto the Au electrode surface to absorb protein A (PA and improve the electrode conductivity. Then PA was dropped onto the surface of DpAu film, used for binding antibody Fc fragments. Next, anti-carbofuran monoclonal antibody was immobilized on the PA modified electrode. Finally, bovine serum albumin (BSA was employed to block the possible remaining active sites avoiding any nonspecific adsorption. The fabrication procedure of the immunosensor was characterized by electrochemical impedance spectroscopy (EIS and cyclic voltammetry (CV, respectively. With the excellent electroconductivity of DpAu and the PA’s oriented immobilization of antibodies, a highly efficient immuno-reaction and detection sensitivity could be achieved. The influences of the electrodeposition time of DpAu, pH of the detection solution and incubation time on the current response of the fabricated immunosensor were investigated. Under optimized conditions, the current response was proportional to the concentration of carbofuran which ranged from 1 to 100 ng/mL and 100 ng/mL to 100 μg/mL. The detection limit was 0.1924 ng/mL. The proposed carbofuran immnuosensor exhibited high specificity, reproducibility, stability and regeneration performance, which may open a new door for ultrasensitive detection of carbofuran residues in vegetables and fruits.

  1. Characteristic of peroxyoxalate-chemiluminescence intensity in the presence of Chlorpheniramine maleate and its analytical application

    International Nuclear Information System (INIS)

    Samadi-Maybodi, Abdolraouf; Akhoondi, Reza

    2011-01-01

    It has been shown that Chlorpheniramine maleate (CPM) increases chemiluminescence intensity of bis-(2,4,6-trichlorophenyl)oxalate (TCPO) with hydrogen peroxide in the presence of biphenylquinoxaline as a fluorophore. In this work, the effect of CPM on the intensity of chemiluminescence (CL) in the system of (TCPO-sodium salicylate-fluorophore-hydrogen peroxide) was investigated. The fall and rise rates constants were also studied. A pooled-intermediate model was used for determining the kinetics parameters of CL with and without CPM. Results indicated that addition of CMP to this system increases the fall rate constant and decreases the rise rate constant. Results also specified that there is a linear relationship between CPA concentration and chemiluminescence intensity in the range 0.66-21.5 μg/ml. Detection limit 0.18 μg/ml and the relative standard deviation (RSD) 2 O 2 - sodium salicylate- fluorescer) in the presence of chlorpheniramine maleate. → Results also introduced a reliable method for determination of chlorpheniramine using peroxyoxalte chemiluminescence system. → A pooled-intermediate model was used for determination the kinetics parameters of chemiluminescence with and without chlorpheniramine maleate. → Results also specified that there is a linear relationship between chlorpheniramine maleate concentration and chemiluminescence intensity.

  2. Facile preparation of disposable immunosensor for Shigella flexneri based on multi-wall carbon nanotubes/chitosan composite

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Guangying, E-mail: zhaogy-user@163.co [Food Safety Key Lab of Zhejiang Province, Department of Food Quality and Safety, Zhejiang Gongshang University, 149, Jiaogong Road, Hangzhou 310035, Zhejiang Province (China); Zhan Xuejia [Food Safety Key Lab of Zhejiang Province, Department of Food Quality and Safety, Zhejiang Gongshang University, 149, Jiaogong Road, Hangzhou 310035, Zhejiang Province (China)

    2010-02-28

    Based on multi-wall carbon nanotubes (MWCNT)/chitosan/horseradish peroxidase labeled antibodies to Shigella flexneri (HRP-anti-S. flexneri) biocomposite film on a screen-printed electrode (SPE) surface, a disposable immunosensor has been developed for the rapid detection of S. flexneri. The HRP-anti-S. flexneri can be entrapped into MWCNT/chitosan composite matrix without other cross-linking agent. Thionine and H{sub 2}O{sub 2} were used as the mediator and substrate, respectively. The surface morphologies of modified films were characterized by atomic force microscope (AFM). Cyclic voltammery (CV) was carried out to characterize the electrochemical properties of the immobilization of materials on the electrode surface and quantified S. flexneri. Due to the strong electrocatalytic properties of MWCNT and HRP toward H{sub 2}O{sub 2}, the response signal was significantly amplified. S. flexneri could be detected by the decrease of the reduction peak current before and after immunoreaction. Under optimal conditions, S. flexneri could be detected in the range of 10{sup 4} to 10{sup 10} cfu mL{sup -1}, with a detection limit of 2.3 x 10{sup 3} cfu mL{sup -1} (S/N = 3). Furthermore, the proposed immunosensor exhibited a satisfactory specificity, reproducibility, stability and accuracy, indicating that the proposed immunosensor has potential application for a facile, rapid and harmless immunoassay.

  3. Recent Advances in Electrochemical Immunosensors

    Directory of Open Access Journals (Sweden)

    Benoît Piro

    2017-04-01

    Full Text Available Immunosensors have experienced a very significant growth in recent years, driven by the need for fast, sensitive, portable and easy-to-use devices to detect biomarkers for clinical diagnosis or to monitor organic pollutants in natural or industrial environments. Advances in the field of signal amplification using enzymatic reactions, nanomaterials such as carbon nanotubes, graphene and graphene derivatives, metallic nanoparticles (gold, silver, various oxides or metal complexes, or magnetic beads show how it is possible to improve collection, binding or transduction performances and reach the requirements for realistic clinical diagnostic or environmental control. This review presents these most recent advances; it focuses first on classical electrode substrates, then moves to carbon-based nanostructured ones including carbon nanotubes, graphene and other carbon materials, metal or metal-oxide nanoparticles, magnetic nanoparticles, dendrimers and, to finish, explore the use of ionic liquids. Analytical performances are systematically covered and compared, depending on the detection principle, but also from a chronological perspective, from 2012 to 2016 and early 2017.

  4. Electrochemiluminescence of luminol enhanced by the synergetic catalysis of hemin and silver nanoparticles for sensitive protein detection.

    Science.gov (United States)

    Jiang, Xinya; Chai, Yaqin; Wang, Haijun; Yuan, Ruo

    2014-04-15

    A novel and ultrasensitive electrochemiluminescence (ECL) immunosensor, which was based on the amplifying ECL of luminol by hemin-reduced graphene oxide (hemin-rGO) and Ag nanoparticles (AgNPs) decorated reduced graphene oxide (Ag-rGO), was constructed for the detection of carcinoembryonic antigen (CEA). For this proposed sandwich-type ECL immunosensor, Au nanoparticles electrodeposited (DpAu) onto hemin-rGO (DpAu/hemin-rGO) constructed the base of the immunosensor. DpAu had outstanding electrical conductivity to promote the electron transfer at the electrode interface and had good biocompatibility to load large amounts of primary antibody (Ab1), which provided an excellent platform for this immunosensor. Moreover, AgNPs and glucose oxidase (GOD) functionalized graphene labeled secondary antibody (Ag-rGO-Ab2-GOD) was designed as the signal probe for the sandwiched immunosensor. Not only did the hemin-rGO improve the electron transfer of the electrode surface, but hemin also further amplified the ECL signal of luminol in the presence of hydrogen peroxide (H2O2). With the aid of Ag-rGO-Ab2-GOD, enhanced signal was obtained by in situ generation of H2O2 and catalysis of AgNPs to ECL reaction of the luminol-H2O2 system. The as-prepared ECL immunosensor exhibited excellent analytical property for the detection of CEA in the range from 0.1 pg mL(-1) to 160 ng mL(-1) with a detection limit of 0.03 pg mL(-1) (SN(-1)=3). © 2013 Published by Elsevier B.V.

  5. Amperometric immunosensor for {alpha}-fetoprotein antigen in human serum based on co-immobilizing dinuclear copper complex and gold nanoparticle doped chitosan film

    Energy Technology Data Exchange (ETDEWEB)

    Gan Ning; Meng Linghua; Wang Feng [State Key Laboratory Base of Novel Functional Materials and Preparation science, Faculty of Material Science and Chemical Engineering of Ninbo University, Ningbo, 315211 (China)], E-mail: ganning@nbu.edu.cn

    2009-09-01

    A sensitive amperometric immunosensor for {alpha}-fetoprotein (AFP), a tumor marker for the diagnosis of hepatocellular carcinoma (HCC), was constructed, The immunosensor is prepared by co-immobilizing [Cu{sub 2}(phen){sub 2}Cl{sub 2}] ({mu}-Cl){sub 2} (CuL), nano-Au/Chitosan(Chit) composite, horseradish peroxidase (HRP) and AFP antibody(anti-AFP) on a glassy carbon electrode (GCE). Firstly, CuL was irreversibly absorb on GCE electrode through {pi}-{pi} stacking interaction; then nano-Au/Chit composite was immobilized onto the electrode because of its excellent membrane-forming ability, finally HRP and anti-AFP was adsorbed onto the surface of the gold nanoparticles to construct GCE | CuL/nanoAu-chit/HRP/anti-AFP immunosensor. The preparation procedure of the electrode was characterized by electrochemical and spectroscopy method. The results showed that this immunosensor exhibited an excellent electrocatalytic response to the reduction of hydrogen peroxide (H{sub 2}O{sub 2}) without the aid of an electron mediator, offers a high-sensitivity (1710 nA {center_dot} ng{sup -1} {center_dot} ml{sup -1}) for the detection of AFP and has good correlation for detection of AFP in the range of 0.2 to 120.0 ng/ml with a detection limit of 0.05 ng/ml. The biosensor showed high selectivity as well as good stability and reproductivity.

  6. A novel photoelectrochemical immunosensor by integration of nanobody and ZnO nanorods for sensitive detection of nucleoside diphosphatase kinase-A

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Anran, E-mail: liuar@seu.edu.cn; Yin, Kaifei; Mi, Li; Ma, Mengyao; Liu, Yuanjian; Li, Ying; Wei, Wei; Zhang, Yuanjian; Liu, Songqin

    2017-06-22

    Nucleoside diphosphatase kinase A (NDPK-A) is a metastasis-suppressor protein and a biomarker that act on a wide range cancer cells to inhibit the potential metastasis. Herein, we present a simple photoelectrochemical immunosensor based on ZnO nanorod arrays for the sensitive detection of NDPK-A. The ZnO nanorod arrays cosensitized with CdS nanoparticles and Mn{sup 2+} displayed a high and stable photocurrent response under irradiation. After anti-NPDK-A nanobodies were immobilized to the ZnO nanorod arrays, the proposed immunosensor can be utilized for detecting NPDK-A by monitoring the changes in the photocurrent signals of the electrode resulting from immunoreaction. Accordingly, the well-designed immunosensor exhibited a low limit of detection (LOD) of 0.3 pg mL{sup −1} and a wide linear range from 0.5 pg mL{sup −1} to 10 μg mL{sup −1}. The R{sup 2} of the regression curve is 0.99782. Meanwhile, the good stability, reproducibility and specificity of the resulting photoelectrochemical biosensor are demonstrated. In addition, the presented work would offer a novel and simple approach for the detection of immunoreactions and provide new insights in popularizing the diagnosis of NPDK-A. - Highlights: • A photoelectrochemical immunosensor based on ZnO NAs and NBs was fabricated. • Cosensitized structure of ZnO NAs, CdS and Mn improved the photocurrent response. • An excellent sensitivity and selectivity of NDPK-A detection was obtained.

  7. Impedimetric immunosensor for human serum albumin detection on a direct aldehyde-functionalized silicon nitride surface

    Energy Technology Data Exchange (ETDEWEB)

    Caballero, David, E-mail: caballero@unistra.fr [Nanobioengineering group-IBEC, Barcelona Science Park, C/ Baldiri Reixach 10-12, 08028 Barcelona (Spain); University of Barcelona, Department of Electronics, C/ Marti i Franques 1, 08028 Barcelona (Spain); Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza (Spain); Martinez, Elena [Nanobioengineering group-IBEC, Barcelona Science Park, C/ Baldiri Reixach 10-12, 08028 Barcelona (Spain); Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza (Spain); Bausells, Joan [Centre Nacional de Microelectronica (CNM-IMB), CSIC, Campus UAB, 08193 Bellaterra (Spain); Errachid, Abdelhamid, E-mail: abdelhamid.errachid-el-salhi@univ-lyon1.fr [Nanobioengineering group-IBEC, Barcelona Science Park, C/ Baldiri Reixach 10-12, 08028 Barcelona (Spain); Universite Claude Bernard - Lyon 1, LSA - UMR 5180, 43 Bd du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Samitier, Josep [Nanobioengineering group-IBEC, Barcelona Science Park, C/ Baldiri Reixach 10-12, 08028 Barcelona (Spain); University of Barcelona, Department of Electronics, C/ Marti i Franques 1, 08028 Barcelona (Spain); Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza (Spain)

    2012-03-30

    Highlights: Black-Right-Pointing-Pointer An impedimetric label-free immunosensor was developed for the specific detection of human serum albumin proteins. Black-Right-Pointing-Pointer Anti-HSA antibodies were covalently immobilized on silicon nitride surfaces using a direct functionalization methodology. Black-Right-Pointing-Pointer Silicon nitride offers multiple advantages compared to other common materials. Black-Right-Pointing-Pointer The proposed sensor has high sensitivity and good selectivity for the detection of HSA proteins. - Abstract: In this work we report the fabrication and characterization of a label-free impedimetric immunosensor based on a silicon nitride (Si{sub 3}N{sub 4}) surface for the specific detection of human serum albumin (HSA) proteins. Silicon nitride provides several advantages compared with other materials commonly used, such as gold, and in particular in solid-state physics for electronic-based biosensors. However, few Si{sub 3}N{sub 4}-based biosensors have been developed; the lack of an efficient and direct protocol for the integration of biological elements with silicon-based substrates is still one of its the main drawbacks. Here, we use a direct functionalization method for the direct covalent binding of monoclonal anti-HSA antibodies on an aldehyde-functionalized Si-p/SiO{sub 2}/Si{sub 3}N{sub 4} structure. This methodology, in contrast with most of the protocols reported in literature, requires less chemical reagents, it is less time-consuming and it does not need any chemical activation. The detection capability of the immunosensor was tested by performing non-faradaic electrochemical impedance spectroscopy (EIS) measurements for the specific detection of HSA proteins. Protein concentrations within the linear range of 10{sup -13}-10{sup -7} M were detected, showing a sensitivity of 0.128 {Omega} {mu}M{sup -1} and a limit of detection of 10{sup -14} M. The specificity of the sensor was also addressed by studying the

  8. Impedimetric immunosensor for human serum albumin detection on a direct aldehyde-functionalized silicon nitride surface

    International Nuclear Information System (INIS)

    Caballero, David; Martinez, Elena; Bausells, Joan; Errachid, Abdelhamid; Samitier, Josep

    2012-01-01

    Highlights: ► An impedimetric label-free immunosensor was developed for the specific detection of human serum albumin proteins. ► Anti-HSA antibodies were covalently immobilized on silicon nitride surfaces using a direct functionalization methodology. ► Silicon nitride offers multiple advantages compared to other common materials. ► The proposed sensor has high sensitivity and good selectivity for the detection of HSA proteins. - Abstract: In this work we report the fabrication and characterization of a label-free impedimetric immunosensor based on a silicon nitride (Si 3 N 4 ) surface for the specific detection of human serum albumin (HSA) proteins. Silicon nitride provides several advantages compared with other materials commonly used, such as gold, and in particular in solid-state physics for electronic-based biosensors. However, few Si 3 N 4 -based biosensors have been developed; the lack of an efficient and direct protocol for the integration of biological elements with silicon-based substrates is still one of its the main drawbacks. Here, we use a direct functionalization method for the direct covalent binding of monoclonal anti-HSA antibodies on an aldehyde-functionalized Si-p/SiO 2 /Si 3 N 4 structure. This methodology, in contrast with most of the protocols reported in literature, requires less chemical reagents, it is less time-consuming and it does not need any chemical activation. The detection capability of the immunosensor was tested by performing non-faradaic electrochemical impedance spectroscopy (EIS) measurements for the specific detection of HSA proteins. Protein concentrations within the linear range of 10 −13 –10 −7 M were detected, showing a sensitivity of 0.128 Ω μM −1 and a limit of detection of 10 −14 M. The specificity of the sensor was also addressed by studying the interferences with a similar protein, bovine serum albumin. The results obtained show that the antibodies were efficiently immobilized and the proteins

  9. A readout circuit dedicated for the detection of chemiluminescence using a silicon photomultiplier

    Science.gov (United States)

    Baszczyk, M.; Dorosz, P.; Mik, L.; Kucewicz, W.; Reczynski, W.; Sapor, M.

    2018-05-01

    A readout circuit dedicated for the detection of the chemiluminescence phenomenon using a silicon photomultiplier (SiPM) is presented. During chemiluminescence, light is generated as a result of chemical reaction. Chemiluminescence is used in many applications within medicine, chemistry, biology and biotechnology, and is one of the most important sensing techniques in biomedical science and clinical medicine. The front-end electronics consist of a preamplifier and a fast shaper—this produces pulses, the peaking time which is 3.6 ns for a single photon and the FWHM is 3.8 ns. The system has been optimised to measure chemiluminescence—it is sensitive at the level of single photons, it generates a low number of overlapping pulses and is accurate. Two methods of signal detection are analysed and compared: the counting of events and amplitude detection. The relationship between the chemiluminescence light intensity and the concentration of the chemical compound (luminol) is linear in the range of the tested concentrations and has strong linearity parameters and low prediction intervals.

  10. A novel signal-on photoelectrochemical immunosensor for detection of alpha-fetoprotein by in situ releasing electron donor.

    Science.gov (United States)

    Chen, Jiexia; Zhao, Guang-Chao

    2017-12-15

    A signal-on photoelectrochemical (PEC) immunosensor was constructed for detecting tumor marker in this work. α-fetoprotein (AFP) was chosen as a model analyte to investigate the prepared procedure and the analytical performance of the exploited sensor. In order to construct the sensor, CdSe QDs were used as photoactive material, biotin conjugated AFP antibody (Bio-anti-AFP) as detecting probe, streptavidin (SA) as signal capturing unit, biotin functionalized apoferritin encapsulated ascorbic acid (Bio-APOAA) as amplification unit, which were assembled onto the electrodes. The sensing strategy was based on in situ enzymatic hydrolysis of Bio-APOAA to release ascorbic acid (AA) as sacrificial electron donor to produce photocurrent. The photocurrent from the immunosensor was monitored as a result of AFP concentrations. The constructed sensing platform displayed high selectivity and good sensitivity for detecting AFP. Under optimal conditions, a wide linear range from 0.001 to 1000ng/mL and a low detection limit of 0.31pg/mL were obtained. The developed immunosensor is expected to be used to determine AFP and other tumor markers in human plasma in clinical laboratories either for pre-cancer screening or cancer monitoring. Moreover, this sensing platform further has the potential to use for the detection of trypsin activity and the corresponding inhibitor-screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A novel label-free voltammetric immunosensor for the detection of {alpha}-fetoprotein using functional titanium dioxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Liang Wenbin [Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Yuan Ruo [Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China)], E-mail: yuanruo@swu.edu.cn; Chai Yaqin; Li Yan; Zhuo Ying [Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China)

    2008-01-01

    A highly sensitive label-free voltammetric immunosensor was developed based on the functional titanium dioxide nanoparticles (PV-NTiP), which was prepared by capping 1,1'-bis-(2-phosphonoethyl)-4,4'-bipyridinium dibromide (PV) on the surface of the titanium dioxide nanoparticles (NTiP) with covalent attachment. The PV-NTiP has prominent biocompatibility, good electron transfer ability, primarily excellent adsorption, large specific surface area and positively charged environment. As a result, the negatively charged gold nanoparticles (NGP) could be adsorbed on the PV-NTiP modified electrode surface by electrostatic adsorption, and then to immobilize {alpha}-1-fetoprotein antibody (anti-AFP) for the assay of {alpha}-1-fetoprotein (AFP). The fabricated procedures and electrochemical behaviors of the immunosensor were characterized by electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and cyclic voltammetry (CV). The anti-AFP/NGP/PV-NTiP modified electrode was sensitive to AFP in linear relation between 1.25 and 200 ng/mL with the correlation coefficient of 0.9982, and the detection limit (S/N = 3) is 0.6 ng/mL under the optimal conditions. In addition, the proposed immunosensor exhibits good sensitivity, selectivity, stability and long-term maintenance of bioactivity and it may be used to immobilize other biomoleculars to develop biosensor for the detection of other antigens or biocompounds.

  12. Washing-free heterogeneous immunosensor using proximity-dependent electron mediation between an enzyme label and an electrode.

    Science.gov (United States)

    Dutta, Gorachand; Kim, Sinyoung; Park, Seonhwa; Yang, Haesik

    2014-05-06

    Washing processes, essential in most heterogeneous labeled assays, have been a big hurdle in simplifying the detection procedure and reducing assay time. Nevertheless, less attention has been paid to washing-free heterogeneous labeled assays. We report a purely washing-free immunosensor that allows fast, sensitive, and single-step detection of prostate-specific antigen in serum with low interference. Proximity-dependent electron mediation of ferrocenemethanol (Fc) between an indium-tin oxide (ITO) electrode and a glucose-oxidase (GOx) label allows us to discriminate between a bound and an unbound label: a bound label offers faster electron mediation than an unbound one. The electrooxidation of Fc at a low applied potential (0.13 V vs Ag/AgCl) and a low electrocatalytic ITO electrode and the oxidation of l-ascorbic acid by l-ascorbate oxidase minimize the effect of the interfering species. With a high concentration of glucose (200 mM), the signal and background levels are hardly dependent on the glucose-concentration variation in the sample. The washing-free immunosensor can detect a concentration of ca. 1 pg/mL for mouse IgG in phosphate-buffered saline and a concentration of ca. 10 pg/mL for prostate-specific antigen spiked in female serum after an incubation period of 10 min. The concentrations measured with actual clinical serum samples are in good agreement with the concentrations measured with a commercial instrument, which renders the washing-free heterogeneous immunosensor appealing for practical use.

  13. Laser-saturated fluorescence of nitric oxide and chemiluminescence measurements in premixed ethanol flames

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Carla S.T.; Barreta, Luiz G.; Sbampato, Maria E.; dos Santos, Alberto M. [Aerothermodynamic and Hypersonic Division, Institute of Advanced Studies - General Command of Aerospatial Technology, Rodovia dos Tamoios, km 5.5, 12228-001 Sao Jose dos Campos - SP (Brazil)

    2010-11-15

    In this study, nitric oxide laser-saturated fluorescence (LSF) measurements were acquired from premixed ethanol flames at atmospheric pressure in a burner. NO-LSF experimental profiles for fuel-rich premixed ethanol flames ({phi} = 1.34 and {phi} = 1.66) were determined through the excitation/detection scheme of the Q{sub 2}(26.5) rotational line in the A{sup 2}{sigma}{sup +} - X{sup 2}{pi} (0,0) vibronic band and {gamma}(0,1) emission band. A calibration procedure by NO doping into the flame was applied to establish the NO concentration profiles in these flames. Chemiluminescent emission measurements in the (0, 0) vibronic emission bands of the OH{sup *} (A{sup 2}{sigma}{sup +} - X{sup 2}{pi}) and CH{sup *}(A{sup 2}{delta} - X{sup 2}{pi}) radicals were also obtained with high spatial and spectral resolution for fuel-rich premixed ethanol flames to correlate them with NO concentrations. Experimental chemiluminescence profiles and the ratios of the integrated areas under emission spectra (A{sub CH*}/A{sub CH*}(max.) and A{sub CH*}/A{sub OH*}) were determined. The relationships between chemiluminescence and NO concentrations were established along the premixed ethanol flames. There was a strong connection between CH{sup *} radical chemiluminescence and NO formation and the prompt-NO was identified as the governing mechanism for NO production. The results suggest the optimum ratio of the chemiluminescence of two radicals (A{sub CH*}/A{sub OH*}) for NO diagnostic purposes. (author)

  14. Application of multi-step excitation schemes for detection of actinides and lanthanides in solutions by luminescence/chemiluminescence laser spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Izosimov, I. [Joint Institute for Nuclear Research, Joliot Curie 6, Dubna 141980 (Russian Federation)

    2016-07-01

    The use of laser radiation with tunable wavelength allows the selective excitation of actinide/lanthanide species with subsequent registration of luminescence/chemiluminescence for their detection. This work is devoted to applications of the time-resolved laser-induced luminescence spectroscopy and time-resolved laser-induced chemiluminescence spectroscopy for the detection of lanthanides and actinides. Results of the experiments on U, Eu, and Sm detection by TRLIF (Time Resolved Laser Induced Fluorescence) method in blood plasma and urine are presented. Data on luminol chemiluminescence in solutions containing Sm(III), U(IV), and Pu(IV) are analyzed. It is shown that appropriate selectivity of lanthanide/actinide detection can be reached when chemiluminescence is initiated by transitions within 4f- or 5f-electron shell of lanthanide/actinide ions corresponding to the visible spectral range. In this case chemiluminescence of chemiluminogen (luminol) arises when the ion of f element is excited by multi-quantum absorption of visible light. The multi-photon scheme of chemiluminescence excitation makes chemiluminescence not only a highly sensitive but also a highly selective tool for the detection of lanthanide/actinide species in solutions. (author)

  15. Core–shell Fe{sub 3}O{sub 4}–Au magnetic nanoparticles based nonenzymatic ultrasensitive electrochemiluminescence immunosensor using quantum dots functionalized graphene sheet as labels

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Weiyan; Zhang, Yan [Key Laboratory of Chemical Sensing and Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China); Ge, Shenguang [Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, University of Jinan, Jinan 250022 (China); Song, Xianrang [Cancer Research Center, Shandong Tumor Hospital, Jinan 250012 (China); Huang, Jiadong [Key Laboratory of Chemical Sensing and Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China); Yan, Mei, E-mail: chm_yanm@ujn.edu.cn [Key Laboratory of Chemical Sensing and Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China); Yu, Jinghua [Key Laboratory of Chemical Sensing and Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China)

    2013-04-03

    Graphical abstract: Core–shell Fe{sub 3}O{sub 4}–Au magnetic nanoparticles and P-GS@QDs were prepared to immobilize Ab{sub 1} and Ab{sub 2} respectively and combined to fabricate a novel sandwich-type ECL immunosensor for detecting CA125 at low concentration. Highlights: ► ECL immunosensor for CA125 based on a microfluidic strategy with a homemade ECL cell was proposed. ► Core–shell Fe{sub 3}O{sub 4}–Au magnetic nanoparticles were employed as the carriers of the primary antibodies. ► CdTe quantum dots functionalized graphene sheet were used for signal amplification. -- Abstract: In this paper, a novel, low-cost electrochemiluminescence (ECL) immunosensor using core–shell Fe{sub 3}O{sub 4}–Au magnetic nanoparticles (AuMNPs) as the carriers of the primary antibody of carbohydrate antigen 125 (CA125) was designed. Graphene sheet (GS) with property of good conductivity and large surface area was a captivating candidate to amplify ECL signal. We successively synthesized functionalized GS by loading large amounts of quantum dots (QDs) onto the poly (diallyldimethyl-ammonium chloride) (PDDA) coated graphene sheet (P-GS@QDs) via self-assembly electrostatic reactions, which were used to label secondary antibodies. The ECL immunosensors coupled with a microfluidic strategy exhibited a wide detection range (0.005–50 U mL{sup −1}) and a low detection limit (1.2 mU mL{sup −1}) with the help of an external magnetic field to gather immunosensors. The method was evaluated with clinical serum sample, receiving good correlation with results from commercially available analytical procedure.

  16. Determination of phenolic compounds using high-performance liquid chromatography with Ce4+-Tween 20 chemiluminescence detection

    International Nuclear Information System (INIS)

    Cui Hua; Zhou Jian; Xu Feng; Lai Chunze; Wan Guohui

    2004-01-01

    A novel method for the simultaneous determination of phenolic compounds such as salicylic acid, resorcinol, phloroglucinol, p-hydroxybenzoic acid, 2,4-dihydroxybenzoic acid, and m-nitrophenol by high-performance liquid chromatography (HPLC) coupled with chemiluminescence (CL) detection was developed. The procedure was based on the chemiluminescent enhancement by phenolic compounds of the cerium(IV)-Tween 20 system in a sulfuric acid medium. The separation was carried out with an isocratic elution or with a gradient elution using a mixture of methanol and 1.5% acetic acid. For six phenolic compounds, the detection limits (3σ) were in the range 1.40-5.02 ng/ml and the relative standard deviations (n=11) for the determination of 0.1 μg/ml compounds were in the range 1.9-2.9%. The CL reaction was well compatible with the mobile phase of HPLC, no baseline drift often occurred in HPLC-CL detection was observed with a gradient elution. The method has been successfully applied to the determination of salicylic acid and resorcinol in Dermatitis Clear Tincture and p-hydroxybenzoic acid in apple juices

  17. Enhancement of periodate-hydrogen peroxide chemiluminescence by nitrogen doped carbon dots and its application for the determination of pyrogallol and gallic acid.

    Science.gov (United States)

    Shah, Syed Niaz Ali; Li, Haifang; Lin, Jin-Ming

    2016-06-01

    A new sensitized chemiluminescence (CL) was developed to broaden the analytical application of KIO4-H2O2 system. The nitrogen doped carbon dots (N-CDs) dramatically boosted the CL intensity of KIO4-H2O2 system which was further enriched by basic medium. In light of EPR analysis, free radical scavenging studies and CL spectra the detail mechanism for the enhancement was conferred in the presence of N-CDs and NaOH. The results suggested that CL of KIO4-H2O2 system in the presence and absence of N-CDs and NaOH proceeds via radical pathway. The enhanced CL was used for the determination of pyrogallol and gallic acid in range of 1.0×10(-4)-1.0×10(-7)M with 4.6×10(-8) and 6.1×10(-8)M limit of detection respectively. The relative standard deviation (RSD) at a concentration of 10(-5) for gallic acid and pyrogallol was 1.4% and 2.3% respectively (n=11). The attained results unveil that the present method is sensitive, faster, simpler and less costly compared to other methods and could be applied to determine polyphenols in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Solid-state chemiluminescence assay for ultrasensitive detection of antimony using on-vial immobilization of CdSe quantum dots combined with liquid–liquid–liquid microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Costas-Mora, Isabel; Romero, Vanesa; Lavilla, Isela; Bendicho, Carlos, E-mail: bendicho@uvigo.es

    2013-07-25

    Graphical abstract: -- Highlights: •Solid-state chemiluminescence based on CdSe QDs was developed. •QDs immobilization in a vial was achieved in a simple and fast way. •Antimony detection was achieved by inhibition of the CdSe QDs/H{sub 2}O{sub 2} CL reaction. •LLLME allowed improving the selectivity and sensitivity of the CL assay. •The capping ligand played a critical role in the selectivity of the CL system. -- Abstract: On-vial immobilized CdSe quantum dots (QDs) are applied for the first time as chemiluminescent probes for the detection of trace metal ions. Among 17 metal ions tested, inhibition of the chemiluminescence when CdSe QDs are oxidized by H{sub 2}O{sub 2} was observed for Sb, Se and Cu. Liquid–liquid–liquid microextraction was implemented in order to improve the selectivity and sensitivity of the chemiluminescent assay. Factors influencing both the CdSe QDs/H{sub 2}O{sub 2} chemiluminescent system and microextraction process were optimized for ultrasensitive detection of Sb(III) and total Sb. In order to investigate the mechanism by which Sb ions inhibit the chemiluminescence of the CdSe QDs/H{sub 2}O{sub 2} system, atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), UV–vis absorption and fluorescence measurements were performed. The selection of the appropriate CdSe QDs capping ligand was found to be a critical issue. Immobilization of QDs caused the chemiluminescence signal to be enhanced by a factor of 100 as compared to experiments carried out with QDs dispersed in the bulk aqueous phase. Under optimized conditions, the detection limit was 6 ng L{sup −1} Sb and the repeatability expressed as relative standard deviation (N = 7) was about 1.3%. An enrichment factor of 95 was achieved within only 3 min of microextraction. Several water samples including drinking, spring, and river waters were analyzed. The proposed method was validated against CRM NWTM-27.2 fortified lake water, and a recovery study was

  19. A label-free electrochemical immunosensor based on the novel signal amplification system of AuPdCu ternary nanoparticles functionalized polymer nanospheres.

    Science.gov (United States)

    Yan, Qin; Yang, Yuying; Tan, Zhaoling; Liu, Qing; Liu, Hui; Wang, Ping; Chen, Lei; Zhang, Daopeng; Li, Yueyun; Dong, Yunhui

    2018-04-30

    A sensitive label-free electrochemical immunosensor was designed using a novel signal amplification system for quantitative detecting hepatitis B surface antigen (HBsAg). Nitrogen-doped graphene quantum dots (N-GQDs) supported surfactant-free AuPdCu ternary nanoparticles (AuPdCu/N-GQDs), which featured with good conductivity and excellent catalytic properties for the reduction of hydrogen peroxide (H 2 O 2 ), was synthesized by a simple and benign hydrothermal procedure. At the same time, the electroactive polymer nanospheres (PS) was synthesized by infinite coordination polymers of ferrocenedicarboxylic acid, which could play as carrier and electronic mediator to load AuPdCu/N-GQDs. The PS not only improved the ability to load antibodies because of the good biocompatibility, but also accelerated electron transport of the electrode interface attribute to plentiful ferrocene unit. Thus, the prepared AuPdCu/N-GQDs@PS has abilities of good biocompatibility, catalytic activity and electrical conductivity to be applied as transducing materials to amplify electrochemical signal in detection of HBsAg. Under optimal conditions, the fabricated immunosensor exhibited high sensitivity and stability in the detection of HBsAg. A linear relationship between current signals and the concentrations of HBsAg was obtained in the range from 10fg/mL to 50ng/mL and the detection limit of HBsAg was 3.3fg/mL (signal-to-noise ratio of 3). Moreover, the designed immunosensor with excellent selectivity, reproducibility and stability shows excellent performance in detection of human serum samples. Furthermore, this label-free electrochemical immunosensor has promising application in clinical diagnosis of HBsAg. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Comparison of Electrochemical Immunosensors and Aptasensors for Detection of Small Organic Molecules in Environment, Food Safety, Clinical and Public Security

    Directory of Open Access Journals (Sweden)

    Benoit Piro

    2016-02-01

    Full Text Available We review here the most frequently reported targets among the electrochemical immunosensors and aptasensors: antibiotics, bisphenol A, cocaine, ochratoxin A and estradiol. In each case, the immobilization procedures are described as well as the transduction schemes and the limits of detection. It is shown that limits of detections are generally two to three orders of magnitude lower for immunosensors than for aptasensors, due to the highest affinities of antibodies. No significant progresses have been made to improve these affinities, but transduction schemes were improved instead, which lead to a regular improvement of the limit of detections corresponding to ca. five orders of magnitude over these last 10 years. These progresses depend on the target, however.

  1. Screening test for rapid food safety evaluation by menadione-catalysed chemiluminescent assay.

    Science.gov (United States)

    Yamashoji, Shiro; Yoshikawa, Naoko; Kirihara, Masayuki; Tsuneyoshi, Toshihiro

    2013-06-15

    The chemiluminescent assay of menadione-catalysed H2O2 production by living mammalian cells was proposed to be useful for rapid food safety evaluation. The tested foods were extracted with water, ethanol and dimethylsulfoxide, and each extract was incubated with NIH3T3, Neuro-2a and HepG2 cells for 4h. Menadione-catalysed H2O2 production by living mammalian cells exposed to each extract was determined by the chemiluminescent assay requiring only 10 min, and the viability of the cells was estimated as percentage based on H2O2 production by intact cells. In this study the cytotoxicity of food was rated in order of inhibitory effect on H2O2 production by intact cells. The well known natural toxins such as Fusarium mycotoxin, tomato toxin tomatine, potato toxin solanine and marine toxins terodotoxin and brevetoxin could be detected by the above chemiluminescent assay. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. A competitive chemiluminescence enzyme immunoassay for rapid and sensitive determination of enrofloxacin

    Science.gov (United States)

    Yu, Fei; Wu, Yongjun; Yu, Songcheng; Zhang, Huili; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B.

    With alkaline phosphatase (ALP)-adamantane (AMPPD) system as the chemiluminescence (CL) detection system, a highly sensitive, specific and simple competitive chemiluminescence enzyme immunoassay (CLEIA) was developed for the measurement of enrofloxacin (ENR). The physicochemical parameters, such as the chemiluminescent assay mediums, the dilution buffer of ENR-McAb, the volume of dilution buffer, the monoclonal antibody concentration, the incubation time, and other relevant variables of the immunoassay have been optimized. Under the optimal conditions, the detection linear range of 350-1000 pg/mL and the detection limit of 0.24 ng/mL were provided by the proposed method. The relative standard deviations were less than 15% for both intra and inter-assay precision. This method has been successfully applied to determine ENR in spiked samples with the recovery of 103%-96%. It showed that CLEIA was a good potential method in the analysis of residues of veterinary drugs after treatment of related diseases.

  3. An Amperometric Immunosensor Based on Multi-Walled Carbon Nanotubes-Thionine-Chitosan Nanocomposite Film for Chlorpyrifos Detection

    Science.gov (United States)

    Sun, Xia; Cao, Yaoyao; Gong, Zhili; Wang, Xiangyou; Zhang, Yan; Gao, Jinmei

    2012-01-01

    In this work, a novel amperometric immunosensor based on multi-walled carbon nanotubes-thionine-chitosan (MWCNTs-THI-CHIT) nanocomposite film as electrode modified material was developed for the detection of chlorpyrifos residues. The nanocomposite film was dropped onto a glassy carbon electrode (GCE), and then the anti-chlorpyrifos monoclonal antibody was covalently immobilized onto the surface of MWCNTs-THI-CHIT/GCE using the crosslinking agent glutaraldehyde (GA). The modification procedure was characterized by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Under the optimized conditions, a linear relationship between the relative change in peak current of different pulse voltammetry (DPV) and the logarithm of chlorpyrifos solution concentration was obtained in the range from 0.1 to 1.0 × 105 ng/mL with a detection limit of 0.046 ng/mL. The proposed chlorpyrifos immunosensor exhibited high reproducibility, stability, and good selectivity and regeneration, making it a potential alternative tool for ultrasensitive detection of chlorpyrifos residues in vegetables and fruits. PMID:23443396

  4. Flame structure of methane/oxygen shear coaxial jet with velocity ratio using high-speed imaging and OH*, CH* chemiluminescence

    Science.gov (United States)

    Shim, Myungbo; Noh, Kwanyoung; Yoon, Woongsup

    2018-06-01

    In this study, the effects of gaseous methane/oxygen injection velocity ratio on the shear coaxial jet flame structure are analyzed using high-speed imaging along with OH* and CH* chemiluminescence. The images show that, as the velocity ratio is increased, the visual flame length increases and wrinkles of the flame front are developed further downstream. The region near the equivalence ratio 1 condition in the flame could be identified by the maximum OH* position, and this region is located further downstream as the velocity ratio is increased. The dominant CH* chemiluminescence is found in the near-injector region. As the velocity ratio is decreased, the signal intensity is higher at the same downstream distance in each flame. From the results, as the velocity ratio is decreased, there is increased entrainment of the external jet, the mixing of the two jets is enhanced, the region near the stoichiometric mixture condition is located further upstream, and consequently, the flame length decreases.

  5. Implementation of a SPR immunosensor for the simultaneous detection of the 22K and 20K hGH isoforms in human serum samples.

    Science.gov (United States)

    de Juan-Franco, Elena; Rodríguez-Frade, J M; Mellado, M; Lechuga, Laura M

    2013-09-30

    We have implemented a Surface Plasmon Resonance (SPR) immunosensor based on a sandwich assay for the simultaneous detection of the two main hGH isoforms, of 22 kDa (22K) and 20 kDa (20K). An oriented-antibody sensor surface specific for both hormone isoforms was assembled by using the biotin-streptavidin system. The immunosensor functionality was checked for the direct detection of the 22K hGH isoform in buffer, which gave high specificity and reproducibility (intra and inter-assay mean coefficients of variation of 8.23% and 9% respectively). The selective determination of the 22K and 20K hGH isoforms in human serum samples in a single assay was possible by using two specific anti-hGH monoclonal antibodies. The detection limit for both hormone isoforms was 0.9 ng mL(-1) and the mean coefficient of variation was below 7.2%. The excellent reproducibility and sensitivity obtained indicate the high performance of this immunosensor for implementing an anti-doping test. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Portable amperometric immunosensor for histamine detection using Prussian blue-chitosan-gold nanoparticle nanocomposite films.

    Science.gov (United States)

    Dong, Xiu-Xiu; Yang, Jin-Yi; Luo, Lin; Zhang, Yi-Feng; Mao, Chuanbin; Sun, Yuan-Ming; Lei, Hong-Tao; Shen, Yu-Dong; Beier, Ross C; Xu, Zhen-Lin

    2017-12-15

    Histamine (HA) is a biogenic amine that can accumulate to high concentration levels in food as a result of microbial activity and can cause toxic effects in consumers. In this work, a portable electrochemical immunosensor capable of detecting HA with high sensitivity and selectivity was developed. Prussian blue-chitosan-gold nanoparticle (PB-CS-AuNP) nanocomposite films with excellent biocompatibility were synthesized and characterized by scanning electron microscopy and energy dispersive X-ray analysis. The PB-CS-AuNP were coated onto a screen-printed electrode by one-step electrodeposition and used to conjugate the HA ovalbumin conjugate (HA-Ag). HA was determined by a competition between the coating HA-Ag and the HRP labeled HA antibody (HRP-HA-Ab). After careful optimization of assay conditions and Box-Behnken analysis, the developed immunosensor showed a linear range from 0.01 to 100μg/mL for HA in fish samples. The average recoveries from spiked samples ranged from 97.25% to 105%. The biosensor also showed good specificity, reproducibility, and stability, indicating its potential application in monitoring HA in a simple and low cost manner. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Electrochemical immunosensor for the milk allergen β-lactoglobulin based on electrografting of organic film on graphene modified screen-printed carbon electrodes.

    Science.gov (United States)

    Eissa, Shimaa; Tlili, Chaker; L'Hocine, Lamia; Zourob, Mohammed

    2012-01-01

    A novel label-free voltammetric immunosensor for sensitive detection of β-lactoglobulin using graphene modified screen printed electrodes has been developed. The derivatization of the graphene electrode surface was achieved by electrochemical reduction of in situ generated 4-nitrophenyl diazonium cations in aqueous acidic solution, followed by electrochemical reduction of the terminal nitro groups to amines. The electrochemical modification protocol was optimized in order to generate monolayer of nitrophenyl groups on the graphene surface without complete passivation of the electrode. Unlike the reported method for graphene functionalization, we demonstrated here the ability of the electrografting of aryl diazonium salt to attach an organic film to the graphene surface in a controlled manner by choosing the suitable grafting protocol. Next, the amine groups on the graphene surface were activated using glutaraldehyde and used for the covalent immobilization of β-lactoglobulin antibodies. Cyclic and differential pulse voltammetry carried out in an aqueous solution containing [Fe(CN)(6)](3-/4-) redox pair have been used for the immunosensor characterization. The results demonstrated that the DPV reduction peak current of [Fe(CN)(6)](3-/4-) decreased linearly with increasing the concentration of β-lactoglobulin due to the formation of antibody-antigen complex on the modified electrode surface. The immunosensor obtained using this novel approach enabled a detection limit of 0.85 pg mL(-1) and a dynamic range from 1 pg mL(-1) to 100 ng mL(-1) of β-lactoglobulin in PBS buffer. In addition, the immunosensor evaluated in different samples including cake, cheese snacks, a sweet biscuit, showing excellent correlation with the results obtained from commercially enzyme-linked immunosorbent assay (ELISA) method. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. A novel electrochemical immunosensor using β-cyclodextrins functionalized silver supported adamantine-modified glucose oxidase as labels for ultrasensitive detection of alpha-fetoprotein.

    Science.gov (United States)

    Gao, Jian; Ma, Hongmin; Lv, Xiaohui; Yan, Tao; Li, Na; Cao, Wei; Wei, Qin

    2015-09-17

    In this work, a novel sandwich-type electrochemical immunosensor based on host-guest interaction was fabricated for the detection of alpha-fetoprotein (AFP). Due to the large specific surface area of multiwalled carbon nanotubes and the unique supramolecular recognition ability of β-cyclodextrins, ferrocenecarboxylic acid (Fc) was incorporated into this sensor platform by host-guest interaction to generate an electrochemical signal. And β-cyclodextrins functionalized silver supported adamantine-modified glucose oxidase (GOD-CD-Ag), was used as a label to improve the analytical performance of the immunosensor by the dual amplification strategy. The obtained GOD-CD-Ag conjugates could convert glucose into gluconic acid with the formation of hydrogen peroxide (H2O2). And then silver nanoparticles could in situ catalyze the reduction of the generated H2O2, dramatically improving the oxidation reaction of Fc. The developed immunosensor shows a wide linear calibration range from 0.001 to 5.0 ng/mL with a low detection limit (0.2 pg/mL) for the detection of AFP. The method, with ideal reproducibility and selectivity, has a wide application prospect in clinical research. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Multifunctional reduced graphene oxide trigged chemiluminescence resonance energy transfer: Novel signal amplification strategy for photoelectrochemical immunoassay of squamous cell carcinoma antigen.

    Science.gov (United States)

    Zhang, Yan; Sun, Guoqiang; Yang, Hongmei; Yu, Jinghua; Yan, Mei; Song, Xianrang

    2016-05-15

    Herein, a photoelectrochemical (PEC) immunoassay is constructed for squamous cell carcinoma antigen (SCCA) detection using zinc oxide nanoflower-bismuth sulfide (Bi2S3) composites as photoactive materials and reduced graphene oxide (rGO) as signal labels. Horseradish peroxidase is used to block sites against nonspecific binding, and then participated in luminol-based chemiluminescence (CL) system. The induced CL emission is acted as an inner light source to excite photoactive materials, simplifying the instrument. A novel signal amplification strategy is stem from rGO because of the rGO acts as an energy acceptor, while luminol serves as a donor to rGO, triggering the CL resonance energy transfer phenomenon between luminol and rGO. Thus, the efficient CL emission to photoactive materials decreases. Furthermore, the signal amplification caused by rGO labeled signal antibodies is related to photogenerated electron-hole pairs: perfect matching of energy levels between rGO and Bi2S3 makes rGO a sink to capture photogenerated electrons from Bi2S3; the increased steric hindrance hinders the electron donor to the surface of Bi2S3 for reaction with the photogenerated holes. On the basis of the novel signal amplification strategy, the proposed immunosensor exhibits excellent analytical performance for PEC detection of SCCA, ranging from 0.8 pg mL(-1) to 80 ng mL(-1) with a low detection limit of 0.21 pg mL(-1). Meanwhile, the designed signal amplification strategy provides a general format for future development of PEC assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Multielement surface plasmon resonance immunosensor for monitoring of blood circulation system

    Science.gov (United States)

    Kostyukevych, Sergey A.; Kostyukevych, Kateryna V.; Khristosenko, Roman V.; Lysiuk, Viktor O.; Koptyukh, Anastasiya A.; Moscalenko, Nadiya L.

    2017-12-01

    The problems related to the development of a multielement immunosensor device with the prism type of excitation of a surface plasmon resonance in the Kretschmann configuration and with the scanning of the incidence angle of monochromatic light aimed at the reliable determination of the levels of three molecular markers of the system of hemostasis (fibrinogen, soluble fibrin, and D-dimer) are considered. We have analyzed the influence of a technology for the production of a gold coating, modification of its surface, and noise effects on the enhancement of sensitivity and stability of the operation of devices. A means of oriented immobilization of monoclonal antibodies on the surface of gold using a multilayer film of copper aminopentacyanoferrate is developed. For the model proteins of studied markers, the calibrating curves (maximum sensitivity of 0.5 μg/ml) are obtained, and the level of fibrinogen in blood plasma of donors is determined. A four-channel modification of the device with an application of a reference channel for comparing the elimination of the noise of temperature fluctuations has been constructed. This device allows one to execute the express-diagnostics of prethrombotic states and the monitoring of the therapy of diseases of the blood circulation system.

  11. Final Technical Report - In-line Uranium Immunosensor

    International Nuclear Information System (INIS)

    Blake, Diane A.

    2006-01-01

    In this project, personnel at Tulane University and Sapidyne Instruments Inc. developed an in-line uranium immunosensor that could be used to determine the efficacy of specific in situ biostimulation approaches. This sensor was designed to operate autonomously over relatively long periods of time (2-10 days) and was able to provide near real-time data about uranium immobilization in the absence of personnel at the site of the biostimulation experiments. An alpha prototype of the in-line immmunosensor was delivered from Sapidyne Instruments to Tulane University in December of 2002 and a beta prototype was delivered in November of 2003. The beta prototype of this instrument (now available commercially from Sapidyne Instruments) was programmed to autonomously dilute standard uranium to final concentrations of 2.5 to 100 nM (0.6 to 24 ppb) in buffer containing a fluorescently labeled anti-uranium antibody and the uranium chelator, 2,9-dicarboxyl-1,10-phenanthroline. The assay limit of detection for hexavalent uranium was 5.8 nM or 1.38 ppb. This limit of detection is well below the drinking water standard of 30 ppb recently promulgated by the EPA. The assay showed excellent precision; the coefficients of variation (CV's) in the linear range of the assay were less than 5% and CV?s never rose above 14%. Analytical recovery in the immunosensors-based assay was assessed by adding variable known quantities of uranium to purified water samples. A quantitative recovery (93.75% - 108.17%) was obtained for sample with concentrations from 7.5 to 20 nM (2-4.75 ppb). In August of 2005 the sensor was transported to Oak Ridge National Laboratory, for testing of water samples at the Criddle test site (see Wu et al., Environ. Sci. Technol. 40:3978-3985 2006 for a description of this site). In this first on-site test, the in-line sensor was able to accurately detect changes in the concentrations of uranium in effluent samples from this site. Although the absolute values for the uranium

  12. Detection of gamma irradiated pepper and papain by chemiluminescence

    International Nuclear Information System (INIS)

    Sattar, Abdus; Delincee, H.; Diehl, J.F.

    1987-01-01

    Chemiluminescence (CL) measurements of black pepper and of papain using luminol and lucigenin reactions were studied. Effects of grinding, irradiation (5-20 kGy) and particle size (750-140 μm) on CL of pepper, and of irradiation (10-30 kGy) on CL of papain, were investigated. All the tested treatments affected the luminescence response in both the luminol and lucigenin reactions; however, the pattern of changes in each case, was inconsistent. Optimum pepper size for maximum luminescence was 560 μm, and optimum irradiation doses were > 15 kGy for pepper and > 20 kGy for papain. Chemiluminescence may possibly be used as an indicator or irradiation treatment for pepper and papain at a dose of 10 kGy or higher, but further research is needed to establish the reliability of this method. (author)

  13. A novel antibody–antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode

    Energy Technology Data Exchange (ETDEWEB)

    Arkan, Elham [Nano Drug Delivery Research Center, Kermanshah University of Medical Sciences, Kermanshah (Iran, Islamic Republic of); Saber, Reza [Department of Medical Nanotechnology, School of Advanced Medical Technologies, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Research Center for Science and Technology in Medicine, Imam Khomeini Hospital, Tehran (Iran, Islamic Republic of); Karimi, Ziba [Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran (Iran, Islamic Republic of); Shamsipur, Mojtaba, E-mail: mshamsipur@yahoo.com [Department of Chemistry, Razi University, Kermanshah (Iran, Islamic Republic of)

    2015-05-18

    Highlights: • Design of a novel impedimetric immunosensor for detection of HER2 in serum samples. • Use of a multiwall carbon nanotube-ionic liquid electrode modified with AuNPs as a base. • Immobilization of monoclonal HER2 antibody on AuNPs/MWCILE using 1,6-hexanedithiol as a cross linker. • Achieving linear dynamic range and limit of detection of 10–110 ng mL{sup −1} and 7.4 ng mL{sup −1}, respectively. • Method development and validation and application to assay of HER2 in biological fluids. - Abstract: A highly sensitive impedimetric immunosensor based on a gold nanoparticles/multiwall carbon nanotube-ionic liquid electrode (AuNPs/MW-CILE) was developed for the determination of human epidermal growth factor receptor 2 (HER2). Gold nanoparticles were used to enhance the extent of immobilization and to retain the immunoactivity of the antibody Herceptin on the electrode. Cyclic voltammetry and electrochemical impedance spectroscopy were employed for characterization of various layers coated onto the AuNPs/MW-CILE. The impedance measurements at different steps were based on the charge transfer kinetics of the [Fe(CN){sub 6}]{sup 3−/4−} redox pair. The immobilization of antibody and the corresponding antigen–antibody interaction at the electrode surface altered the interfacial electron transfer. The interactions of antibody with various concentrations of antigen were also monitored via the change of impedance response. The results showed that the charge transfer resistance increases linearly with increasing concentrations of HER2 antigen. The linear range and limit of detection were found as 10–110 ng mL{sup −1} and 7.4 ng mL{sup −1}, respectively. The sensitivity and specificity of the immunosensor were validated. The results showed that the prepared immunosensor is a useful tool for screening of trace amounts of HER2 in serum samples of breast cancer patients.

  14. Capacitive immunosensor for C-reactive protein quantification

    KAUST Repository

    Sapsanis, Christos

    2015-08-02

    We report an agglutination-based immunosensor for the quantification of C-reactive protein (CRP). The developed immunoassay sensor requires approximately 15 minutes of assay time per sample and provides a sensitivity of 0.5 mg/L. We have measured the capacitance of interdigitated electrodes (IDEs) and quantified the concentration of added analyte. The proposed method is a label free detection method and hence provides rapid measurement preferable in diagnostics. We have so far been able to quantify the concentration to as low as 0.5 mg/L and as high as 10 mg/L. By quantifying CRP in serum, we can assess whether patients are prone to cardiac diseases and monitor the risk associated with such diseases. The sensor is a simple low cost structure and it can be a promising device for rapid and sensitive detection of disease markers at the point-of-care stage.

  15. An Electrochemical Immunosensor for Detection of Staphylococcus aureus Bacteria Based on Immobilization of Antibodies on Self-Assembled Monolayers-Functionalized Gold Electrode

    Directory of Open Access Journals (Sweden)

    Abderrazak Maaref

    2012-10-01

    Full Text Available The detection of pathogenic bacteria remains a challenge for the struggle against biological weapons, nosocomial diseases, and for food safety. In this research, our aim was to develop an easy-to-use electrochemical immunosensor for the detection of pathogenic Staphylococcus aureus ATCC25923. The biosensor was elaborated by the immobilization of anti-S. aureus antibodies using a self-assembled monolayer (SAMs of 3-Mercaptopropionic acid (MPA. These molecular assemblies were spontaneously formed by the immersion of the substrate in an organic solvent containing the SAMs that can covalently bond to the gold surface. The functionalization of the immunosensor was characterized using two electrochemical techniques: cyclic voltammetry (CV and electrochemical impedance spectroscopy (EIS. Here, the analysis was performed in phosphate buffer with ferro/ferricyanide as the redox probe. The EIS technique was used for affinity assays: antibody-cell binding. A linear relationship between the increment in the electron transfer resistance (RCT and the logarithmic value of S. aureus concentration was observed between 10 and 106 CFU/mL. The limit of detection (LOD was observed at 10 CFU/mL, and the reproducibility was calculated to 8%. Finally, a good selectivity versus E. coli and S. epidermidis was obtained for our developed immunosensor demonstrating its specificity towards only S. aureus.

  16. Analysis of chemiluminescence measurements by grey-scale ICCD and colour digital cameras

    International Nuclear Information System (INIS)

    Migliorini, F; Maffi, S; De Iuliis, S; Zizak, G

    2014-01-01

    Spectral, grey-scale and colour chemiluminescence measurements of C 2 * and CH* radicals' emission are carried out on the flame front of a methane–air premixed flame at different equivalence ratios. To this purpose, properly spatially resolved optical equipment has been implemented in order to reduce the background emission from other burned gas regions. The grey-scale (ICCD + interference filters) and RGB colour (commercial digital camera) approaches have been compared in order to find a correspondence between the C 2 * and the green component, as well as the CH* and the blue component of the emission intensities. The C 2 */CH* chemiluminescence ratio has been investigated at different equivalence ratios and a good correlation has been obtained, showing the possibility of sensing the equivalence ratio in practical systems. The grey-scale and colour chemiluminescence analysis has then been applied to a meso-scale not premixed swirl combustor fuelled with a methane–air mixture and operating at 0.3 MPa. 2D results are presented and discussed in this work. (paper)

  17. A dual-type responsive electrochemical immunosensor for quantitative detection of PCSK9 based on n-C60-PdPt/N-GNRs and Pt-poly (methylene blue) nanocomposites.

    Science.gov (United States)

    Li, Yan; He, Junlin; Chen, Jun; Niu, Yazhen; Zhao, Yilin; Zhang, Yuchan; Yu, Chao

    2018-03-15

    In this study, a dual-type responsive electrochemical immunosensor was developed for the quantitative detection of proprotein convertase subtilisin/kexin type 9 (PCSK9), a potential biomarker of cardiovascular disease in serum. N-doped graphene nanoribbons (N-GNRs) with good conductivity were used as the sensing matrix modifying the glassy carbon electrode. Palladium platinum alloy (PdPt) nanoparticles with high catalytic performance toward the reduction of hydrogen peroxide (H 2 O 2 ) were reduced onto amino-functionalized fullerene (n-C 60 -PdPt) and significantly amplified the electrochemical signal recorded by the amperometric i-t curve. Furthermore, staphylococcus protein A (SPA) with antibody orientation function was introduced to improve the immunoreaction efficiency. Accordingly, a label-free immunosensor was fabricated based on n-C 60 -PdPt/N-GNRs for the quick detection of PCSK9. Meanwhile, to realize ultrasensitive detection of PCSK9, Pt-poly (methylene blue) (Pt-PMB) nanocomposites synthesized by a one-pot method for the first time were used as a novel signal label, which exhibited uniform morphology as well as good conductivity and produced an electrochemical signal recorded by differential pulse voltammetry (DPV). Herein, a novel sandwich-type immunosensor was designed using n-C 60 -PdPt/N-GNRs as the sensing matrix and Pt-PMB as the signal label for sensitive detection of PCSK9. Under optimal conditions, the label-free immunosensor showed a linear range of 10pgmL -1 to 100ngmL -1 with a detection limit of 3.33pgmL -1 (S/N=3), and the sandwich-type immunosensor exhibited a linear range of 100 fg mL -1 to 100ngmL -1 with a detection limit of 0.033pgmL -1 (S/N=3) for PCSK9 detection, indicating its potential application in clinical bioassay analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A reagentless electrochemiluminescent immunosensor for apurinic/apyrimidinic endonuclease 1 detection based on the new Ru(bpy){sub 3}{sup 2+}/bi-arginine system

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Min; Chai, Xi Deng Ya-Qin; Han, Jing; Gui, Guo-Feng; Yuan, Ruo, E-mail: yuanruo@swu.edu.cn; Zhuo, Ying, E-mail: yingzhuo@swu.edu.cn

    2014-10-10

    Highlights: • A reagentless ECL biosensor based on the new Ru(bpy){sub 3}{sup 2+}/bi-arginine system. • The successful preparation of bi-Arg/Au@Fe3O4–rGO as enhancer. • Using the APE-1 as target by the sandwich-type immunoassay format. - Abstract: Apurinic/apyrimidinic endonuclease 1 (APE-1), a kind of multifunctional protein widely-distributed in the body, plays an essential role in the DNA base excision repair and serves as multiple possible roles in the response of human cancer to radiotherapy and chemotherapy. In this work, an ultrasensitive solid-state electrochemiluminescence (ECL) immunosensor is designed to determine APE-1 based on the new Ru(bpy){sub 3}{sup 2+}/bi-arginine system. The bi-arginine (bi-Arg) is decorated on the Au nanoparticles functionalized magnetic Fe{sub 3}O{sub 4}/reduced graphene oxide (bi-Arg/Au@Fe{sub 3}O{sub 4}–rGO) according to the self-assembling and covalent cross-linking interaction to obtain the functionalized nanocomposite of bi-Arg/Au@Fe{sub 3}O{sub 4}–rGO. Herein, the bi-Arg/Au@Fe{sub 3}O{sub 4}–rGO plays not only an amplification label to enhance the ECL signal of Ru(bpy){sub 3}{sup 2+} due to the coreactant of bi-Arg but also an ideal nanocarrier to load numerous secondary antibody. Based on sandwich-type immunoassay format, this proposed method offers a linear range of 1.0 fg mL{sup −1}–5.0 pg mL{sup −1} and an estimated detection limit of 0.3 fg mL{sup −1} for the APE-1. Moreover, the reagentless ECL immunosensor also exhibits high sensitivity, excellent selectivity and good stability, which has greatly potential development and application in clinical diagnostics, immunology and biomedical research.

  19. A Sandwich HIV p24 Amperometric Immunosensor Based on a Direct Gold Electroplating-Modified Electrode

    Directory of Open Access Journals (Sweden)

    Ning Gan

    2012-05-01

    Full Text Available Acquired immune deficiency syndrome (AIDS is a severe communicable immune deficiency disease caused by the human immune deficiency virus (HIV. The analysis laboratory diagnosis of HIV infection is a crucial aspect of controlling AIDS. The p24 antigen, the HIV-1 capsid protein, is of considerable diagnostic interest because it is detectable several days earlier than host-generated HIV antibodies following HIV exposure. We present herein a new sandwich HIV p24 immunosensor based on directly electroplating an electrode surface with gold nanoparticles using chronoamperometry, which greatly increased the conductivity and reversibility of the electrode. Under optimum conditions, the electrochemical signal showed a linear relationship with the concentration of p24, ranging from 0.01 ng/mL to 100 ng/mL (R > 0.99, and the detection limit was 0.008 ng/mL. Compared with ELISA, this method increased the sensitivity by more than two orders of magnitude (the sensitivity of ELISA for p24 is about 1 ng/mL. This immunosensor may be broadly applied to clinical samples, being distinguished by its ease of use, mild reaction conditions, guaranteed reproducibility, and good anti-interference ability.

  20. A sandwich HIV p24 amperometric immunosensor based on a direct gold electroplating-modified electrode.

    Science.gov (United States)

    Zheng, Lei; Jia, Liyong; Li, Bo; Situ, Bo; Liu, Qinlan; Wang, Qian; Gan, Ning

    2012-05-18

    Acquired immune deficiency syndrome (AIDS) is a severe communicable immune deficiency disease caused by the human immune deficiency virus (HIV). The analysis laboratory diagnosis of HIV infection is a crucial aspect of controlling AIDS. The p24 antigen, the HIV-1 capsid protein, is of considerable diagnostic interest because it is detectable several days earlier than host-generated HIV antibodies following HIV exposure. We present herein a new sandwich HIV p24 immunosensor based on directly electroplating an electrode surface with gold nanoparticles using chronoamperometry, which greatly increased the conductivity and reversibility of the electrode. Under optimum conditions, the electrochemical signal showed a linear relationship with the concentration of p24, ranging from 0.01 ng/mL to 100 ng/mL (R > 0.99), and the detection limit was 0.008 ng/mL. Compared with ELISA, this method increased the sensitivity by more than two orders of magnitude (the sensitivity of ELISA for p24 is about 1 ng/mL). This immunosensor may be broadly applied to clinical samples, being distinguished by its ease of use, mild reaction conditions, guaranteed reproducibility, and good anti-interference ability.

  1. Self-assembled monolayers-based immunosensor for detection of Escherichia coli using electrochemical impedance spectroscopy

    International Nuclear Information System (INIS)

    Geng Ping; Zhang Xinai; Meng Weiwei; Wang Qingjiang; Zhang Wen; Jin Litong; Feng Zhen; Wu Zirong

    2008-01-01

    An electrochemical impedance immunosensor for the detection of Escherichia coli was developed by immobilizing anti-E. coli antibodies at an Au electrode. The immobilization of antibodies at the Au electrode was carried out through a stable acyl amino ester intermediate generated by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydrosuccinimide (NHS), which could condense antibodies reproducibly and densely on the self-assembled monolayer (SAM). The surface characteristics of the immunosensor before and after the binding reaction of antibodies with E. coli were characterized by atomic force microscopy (AFM). The immobilization of antibodies and the binding of E. coli cells to the electrode could increase the electro-transfer resistance, which was directly detected by electrochemical impedance spectroscopy (EIS) in the presence of Fe(CN) 6 3- /Fe(CN) 6 4- as a redox probe. A linear relationship between the electron-transfer resistance and the logarithmic value of E. coli concentration was found in the range of E. coli cells from 3.0 x 10 3 to 3.0 x 10 7 cfu mL -1 with the detection limit of 1.0 x 10 3 cfu mL -1 . With preconcentration and pre-enrichment steps, it was possible to detect E. coli concentration as low as 50 cfu/mL in river water samples

  2. Nanoparticle-Based Electrochemical Immunosensor for the Detection of Phosphorylated Acetylcholinesterase: An Exposure Biomarker of Organophosphate Pesticides and Nerve AgentsOrganophosphate Pesticides and Nerve Agents

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guodong; Wang, Jun; Barry, Richard C.; Petersen, Catherine E.; Timchalk, Charles; Gassman, Paul L.; Lin, Yuehe

    2008-11-01

    A nanoparticle-based electrochemical immunosensor has been developed for the detection of phosphorylated acetylcholinesterase (AChE) adducts, which is a potential exposure biomarker for organophosphate pesticides (OP) and chemical warfare nerve agent exposures. Zirconia nanoparticles (ZrO2 NPs) were used as selective sorbents to capture the phosphorylated AChE adduct, and quantum dots (ZnS@CdS, QDs) were used as tags to label monoclonal anti-AChE antibody to track the immunorecognition events. The sandwich-like immunoreactions were performed among the ZrO2 NPs, which were pre-coated on a screen printed electrode (SPE) by electrodeposition, phosphorylated AChE and QD-anti-AChE. The captured QD tags were determined on the SPE by electrochemical stripping analysis of its metallic component (cadmium) after an acid-dissolution step. Paraoxon was used as a model OP insecticide to prepare the phosphorylated AChE adduct to demonstrate the proof of principle for this sensor technology. The paraoxon-AChE adduct was characterized by Fourier Transform Infrared Spectrum, and the binding affinity of anti-AChE to the paraoxon-AChE was validated with an enzyme-linked immunosorbent assay. The parameters (e.g., amount of ZrO2 NP, QD-anti-AChE concentration,) that govern the electrochemical response of immunosensors were optimized. The voltammetric response of the immunosensor is highly linear over the range of 10 pM to 4 nM paraoxon-AChE, and the limit of detection is estimated to be 8 pM. This new nanoparticle-based electrochemical immunosensor thus provides a sensitive and quantitative tool for biomonitoring exposure to OP pesticides and nerve agents.

  3. Application on Gold Nanoparticles-Dotted 4-Nitrophenylazo Graphene in a Label-Free Impedimetric Deoxynivalenol Immunosensor

    Directory of Open Access Journals (Sweden)

    Christopher Edozie Sunday

    2015-02-01

    Full Text Available In this paper, we report a new concept to construct a label-free electrochemical inhibition-based immunosensor for the detection of the mycotoxin deoxynivalenol (DON in cereal samples. The electrochemical impedance spectroscopy of tris(bipyridine ruthenium (II chloride was used as a marker enhanced with gold nanoparticles-dotted 4-nitrophenylazo functionalized graphene (AuNp/G/PhNO2 nanocatalyst mediated in Nafion on a glassy carbon electrode. Under the optimized conditions, the formation of immunocomplexes inhibited electron flow and increased the charge transfer resistance of the sensing interface linearly. The change in impedance was proportional to DON concentrations in the range of 6–30 ng/mL with a sensitivity and detection limit of 32.14 ΩL/ng and 0.3 µg/mL, respectively, which compares favorably with the ELISA result. The proposed sensor had a stability of 80.3%, good precision and selectivity in DON standard solution containing different interfering agents, indicating promising application prospect for this strategy in designing impedimetric, electrochemiluminescent, voltammetric or amperometric sensors.

  4. Observation of chemiluminescence induced by hydrodynamic cavitation in microchannels.

    Science.gov (United States)

    Podbevsek, D; Colombet, D; Ledoux, G; Ayela, F

    2018-05-01

    We have performed hydrodynamic cavitation experiments with an aqueous luminol solution as the working fluid. Light emission, together with the high frequency noise which characterizes cavitation, was emitted by the two-phase flow, whereas no light emission from luminol was recorded in the single phase liquid flow. Light emission occurs downstream transparent microdiaphragms. The maximum level of the recorded signal was around 180 photons per second with flow rates of 380 µl/s, that corresponds to a real order of magnitude of the chemiluminescence of 75,000 photons per second. The yield of emitted photons increases linearly with the pressure drop, which is proportional to the square of the total flow rate. Chemiluminescence of luminol is a direct and a quantitative demonstration of the presence of OH hydroxyl radicals created by hydrodynamic cavitation. The presented method could be a key to optimize channel geometry for processes where radical production is essential. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. An enhanced cerium(IV)-rhodamine 6G chemiluminescence system using guest-host interactions in a lab-on-a-chip platform for estimating the total phenolic content in food samples.

    Science.gov (United States)

    Al Haddabi, Buthaina; Al Lawati, Haider A J; Suliman, FakhrEldin O

    2016-04-01

    Two chemiluminescence-microfluidic (CL-MF) systems, e.g., Ce(IV)-rhodamine B (RB) and Ce(IV)-rhodamine 6G (R6G), for the determination of the total phenolic content in teas and some sweeteners were evaluated. The results indicated that the Ce(IV)-R6G system was more sensitive in comparison to the Ce(IV)-RB CL system. Therefore, a simple (CL-MF) method based on the CL of Ce(IV)-R6G was developed, and the sensitivity, selectivity and stability of this system were evaluated. Selected phenolic compounds (PCs), such as quercetin (QRC), catechin (CAT), rutin (RUT), gallic acid (GA), caffeic acid (CA) and syringic acid (SA), produced analytically useful chemiluminescence signals with low detection limits ranging from 0.35 nmol L(-1) for QRC to 11.31 nmol L(-1) for SA. The mixing sequence and the chip design were crucial, as the sensitivity and reproducibility could be substantially affected by these two factors. In addition, the anionic surfactant (i.e., sodium dodecyl sulfate (SDS)) can significantly enhance the CL signal intensity by as much as 300% for the QRC solution. Spectroscopic studies indicated that the enhancement was due to a strong guest-host interaction between the cationic R6G molecules and the anionic amphiphilic environment. Other parameters that could affect the CL intensities of the PCs were carefully optimized. Finally, the method was successfully applied to tea and sweetener samples. Six different tea samples exhibited total phenolic/antioxidant levels from 7.32 to 13.5 g per 100g of sample with respect to GA. Four different sweetener samples were also analyzed and exhibited total phenolic/antioxidant levels from 500.9 to 3422.9 mg kg(-1) with respect to GA. The method was selective, rapid and sensitive when used to estimate the total phenolic/antioxidant level, and the results were in good agreement with those reported for honey and tea samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Comparison of ultraviolet absorbance and NO-chemiluminescence for ozone measurement in wildfire plumes at the Mount Bachelor Observatory

    Science.gov (United States)

    Gao, Honglian; Jaffe, Daniel A.

    2017-10-01

    The goal of this paper is to evaluate the accuracy of the commonly used ozone (O3) instrument (the ultraviolet (UV) photometer) against a Federal Reference Method (Nitric Oxide -chemiluminescence) for ozone measurement in wildfire smoke plumes. We carried out simultaneous ozone measurement with two UV O3 photometers and one nitric oxide-chemiluminescence (NO-CL) ozone detectors during wildfire season (Aug. 1-Sept. 30) in 2015 at the Mount Bachelor Observatory (MBO, 2763 m above mean sea level, Oregon, USA). The UV O3 shows good agreement and excellent correlation to NO-CL O3, with linear regression slopes close to unity and R2 of 0.92 for 1-h average data and R2 of 0.93 for O3 daily maximum 8-h average (MDA8). During this two-month period we identified 35 wildfire events. Ozone enhancements in those wildfire plumes measured by NO-CL O3 and UV O3 monitors also show good agreement and excellent linear correlation, with a slope and R2 of 1.03 and 0.86 for O3 enhancements (ΔO3) and 1.00 and 0.98 for carbon monoxide (CO)-normalized ozone enhancement ratios (ΔO3/ΔCO), respectively. Overall, the UV O3 was found to have a positive bias of 4.7 ± 2.8 ppbv compared to the NO-CL O3. The O3 bias between NO-CL O3 and UV O3 is independent of wildfire plume tracers such as CO, particulate matter (PM1), aerosol scattering, and ultrafine particles. The results demonstrate that the UV O3 absorbance method is reliable, even in highly concentrated wildfire plumes.

  7. A sandwich electrochemical immunosensor for Salmonella pullorum and Salmonella gallinarum based on a screen-printed carbon electrode modified with an ionic liquid and electrodeposited gold nanoparticles

    International Nuclear Information System (INIS)

    Fei, Jianfeng; Dou, Wenchao; Zhao, Guangying

    2015-01-01

    This article describes an electrochemical immunosensor for rapid determination of Salmonella pullorum and Salmonella gallinarum. The first step in the preparation of the immunosensor involves the electrodeposition of gold nanoparticles used for capturing antibody and enhancing signals. In order to generate a benign microenvironment for the antibody, the ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate was used to modify the surface of a screen-printed carbon electrode (SPCE). The single steps of modification were monitored via cyclic voltammetry and electrochemical impedance spectroscopy. Based on these findings, a sandwich immunoassay was worked out for the two Salmonella species by immobilizing the respective unlabeled antibodies on the SPCE. Following exposure to the analytes, secondary antibody (labeled with HRP) is added to form the sandwich. After adding hydrogen peroxide and thionine, the latter is oxidized and its signal measured via CV. A linear response to the Salmonella species is obtained in the 10 4 to 10 9 cfu · mL −1 concentration range, and the detection limits are 3.0 × 10 3 cfu · mL −1 for both species (at an SNR of 3). This assay is sensitive, highly specific, acceptably accurate and reproducible. Given its low detection limit, it represents a promising tool for the detection of S. pullorum, S. gallinarum, and - conceivably - of other food-borne pathogens by exchanging the antibody. (author)

  8. Projection model for flame chemiluminescence tomography based on lens imaging

    Science.gov (United States)

    Wan, Minggang; Zhuang, Jihui

    2018-04-01

    For flame chemiluminescence tomography (FCT) based on lens imaging, the projection model is essential because it formulates the mathematical relation between the flame projections captured by cameras and the chemiluminescence field, and, through this relation, the field is reconstructed. This work proposed the blurry-spot (BS) model, which takes more universal assumptions and has higher accuracy than the widely applied line-of-sight model. By combining the geometrical camera model and the thin-lens equation, the BS model takes into account perspective effect of the camera lens; by combining ray-tracing technique and Monte Carlo simulation, it also considers inhomogeneous distribution of captured radiance on the image plane. Performance of these two models in FCT was numerically compared, and results showed that using the BS model could lead to better reconstruction quality in wider application ranges.

  9. Numerical and Experimental Investigation of Computed Tomography of Chemiluminescence for Hydrogen-Air Premixed Laminar Flames

    Directory of Open Access Journals (Sweden)

    Liang Lv

    2016-01-01

    Full Text Available Computed tomography of chemiluminescence (CTC is a promising technique for combustion diagnostics, providing instantaneous 3D information of flame structures, especially in harsh circumstance. This work focuses on assessing the feasibility of CTC and investigating structures of hydrogen-air premixed laminar flames using CTC. A numerical phantom study was performed to assess the accuracy of the reconstruction algorithm. A well-designed burner was used to generate stable hydrogen-air premixed laminar flames. The OH⁎ chemiluminescence intensity field reconstructed from 37 views using CTC was compared to the OH⁎ chemiluminescence distributions recorded directly by a single ICCD camera from the side view. The flame structures in different flow velocities and equivalence ratios were analyzed using the reconstructions. The results show that the CTC technique can effectively indicate real distributions of the flame chemiluminescence. The height of the flame becomes larger with increasing flow velocities, whereas it decreases with increasing equivalence ratios (no larger than 1. The increasing flow velocities gradually lift the flame reaction zones. A critical cone angle of 4.76 degrees is obtained to avoid blow-off. These results set up a foundation for next studies and the methods can be further developed to reconstruct 3D structures of flames.

  10. Scalable fabrication of immunosensors based on carbon nanotube polymer composites

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, Ernest; Gonzalez-Guerrero, Ana B [Institut Catala de Nanotecnologia, Campus Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain); Orozco, Jahir; Jimenez-Jorquera, Cecilia; Fernandez-Sanchez, Cesar [Instituto de Microelectronica de Barcelona, CNM-IMB (CSIC), Campus Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain); Calle, Ana; Lechuga, Laura M [Instituto de Microelectronica de Madrid, CNM-IMM (CSIC), Isaac Newton 8, 28760 Tres Cantos, Madrid (Spain)], E-mail: Ernest.Mendoza.icn@uab.es

    2008-02-20

    In this work we present the fabrication and characterization of immunosensors based on polystyrene (PS)-multiwalled carbon nanotube (MWCNT) composites. The electrochemical properties of the sensors have been investigated and show that the surface area is increased upon addition of the MWCNT-PS layer. Furthermore, a plasma activation process is used to partially remove the PS and expose the MWCNTs. This results in a huge increase in the electrochemical area and opens up the possibility of binding biomolecules to the MWCNT wall. The MWCNTs have been functionalized covalently with a model antibody (rabbit IgG). The biosensors have been tested using amperometric techniques and show detection limits comparable to standard techniques such as ELISA.

  11. Electrochemical immunoassay for thyroxine detection using cascade catalysis as signal amplified enhancer and multi-functionalized magnetic graphene sphere as signal tag

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jing; Zhuo, Ying, E-mail: yingzhuo@swu.edu.cn; Chai, Yaqin; Yu, Yanqing; Liao, Ni; Yuan, Ruo, E-mail: yuanruo@swu.edu.cn

    2013-08-06

    Graphical abstract: -- Highlights: •A reusable electrochemical immunosensor is developed for thyroxine detection. •Cascade catalysis as signal amplified enhancer. •Multi-functionalized magnetic graphene sphere as signal tag. •The novel strategy has the advantages of high sensitivity, good selectivity and reproducibility. -- Abstract: This paper constructed a reusable electrochemical immunosensor for the detection of thyroxine at an ultralow concentration using cascade catalysis of cytochrome c (Cyt c) and glucose oxidase (GOx) as signal amplified enhancer. It is worth pointing out that numerous Cyt c and GOx were firstly carried onto the double-stranded DNA polymers based on hybridization chain reaction (HCR), and then the amplified responses could be achieved by cascade catalysis of Cyt c and GOx recycling with the help of glucose. Moreover, multi-functionalized magnetic graphene sphere was synthesized and used as signal tag, which not only exhibited good mechanical properties, large surface area and an excellent electron transfer rate of graphene, but also possessed excellent redox activity and desirable magnetic property. With a sandwich-type immunoreaction, the proposed cascade catalysis amplification strategy could greatly enhance the sensitivity for the detection of thyroxine. Under the optimal conditions, the immunosensor showed a wide linear ranged from 0.05 pg mL{sup −1} to 5 ng mL{sup −1} and a low detection limit down to 15 fg mL{sup −1}. Importantly, the proposed method offers promise for reproducible and cost-effective analysis of biological samples.

  12. A sensitive electrochemical immunosensor based on poly(2-aminobenzylamine) film modified screen-printed carbon electrode for label-free detection of human immunoglobulin G.

    Science.gov (United States)

    Putnin, Thitirat; Jumpathong, Watthanachai; Laocharoensuk, Rawiwan; Jakmunee, Jaroon; Ounnunkad, Kontad

    2018-08-01

    This work focuses on fabricating poly(2-aminobenzylamine)-modified screen-printed carbon electrode as an electrochemical immunosensor for the label-free detection of human immunoglobulin G. To selectively detect immunoglobulin G, the anti-immunoglobulin G antibody with high affinity to immunoglobulin G was covalently linked with the amine group of poly(2-aminobenzylamine) film-deposited screen-printed carbon electrode. The selectivity for immunoglobulin G was subsequently assured by being challenged with redox-active interferences and adventitious adsorption did not significantly interfere the analyte signal. To obviate the use of costly secondary antibody, the [Fe(CN) 6 ] 4-/3- redox probe was instead applied to measure the number of human immunoglobulin G through the immunocomplex formation that is quantitatively related to the level of the differential pulse voltammetric current. The resulting immunosensor exhibited good sensitivity with the detection limit of 0.15 ng mL -1 , limit of quantitation of 0.50 ng mL -1 and the linear range from 1.0 to 50 ng mL -1 . Given those striking analytical performances and the affordability arising from using cheap screen-printed carbon electrode with label-free detection, the immunosensor serves as a promising model for the next-step development of a diagnostic tool.

  13. Introduction to biosensors from electric circuits to immunosensors

    CERN Document Server

    Yoon, Jeong-Yeol

    2016-01-01

    This book equips students with a thorough understanding of various types of sensors and biosensors that can be used for chemical, biological, and biomedical applications, including but not limited to temperature sensors, strain sensor, light sensors, spectrophotometric sensors, pulse oximeter, optical fiber probes, fluorescence sensors, pH sensor, ion-selective electrodes, piezoelectric sensors, glucose sensors, DNA and immunosensors, lab-on-a-chip biosensors, paper-based lab-on-a-chip biosensors, and microcontroller-based sensors. The author treats the study of biosensors with an applications-based approach, including over 15 extensive, hands-on labs given at the end of each chapter. The material is presented using a building-block approach, beginning with the fundamentals of sensor design and temperature sensors, and ending with more complicated biosensors. New to this second edition are sections on op-amp filters, pulse oximetry, meat quality monitoring, advanced fluorescent dyes, autofluorescence, various...

  14. Electrochemical immunosensor for ethinylestradiol using diazonium salt grafting onto silver nanoparticles-silica-graphene oxide hybrids.

    Science.gov (United States)

    Cincotto, Fernando H; Martínez-García, Gonzalo; Yáñez-Sedeño, Paloma; Canevari, Thiago C; Machado, S A S; Pingarrón, José M

    2016-01-15

    This work describes the preparation of an electrochemical immunosensor for ethinylestradiol (EE2) based on grafting of diazonium salt of 4-aminobenzoic acid onto a glassy carbon electrode modified with silver nanoparticles/SiO2/graphene oxide hybrid followed by covalent binding of anti-ethinylestradiol (anti-EE2) to activated carboxyl groups. A competitive immunoassay was developed for the determination of the hormone using peroxidase-labeled ethinylestradiol (HRP-EE2) and measurement of the amperometric response at -200mV in the presence of hydroquinone (HQ) as redox mediator. The calibration curve for EE2 exhibited a linear range between 0.1 and 50ng/mL (r(2)=0.996), with a detection limit of 65pg/mL. Interference studies with other hormones related with EE2 revealed the practical specificity of the developed method for the analyte. A good reproducibility, with RSD=4.5% (n=10) was also observed. The operating stability of a single bioelectrode modified with anti-EE2 was maintained at least for 15 days when it was stored at 4°C under humid conditions between measurements. The developed immunosensor was applied to the analysis of spiked urine with good results. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Chemiluminescence in cryogenic matrices

    Science.gov (United States)

    Lotnik, S. V.; Kazakov, Valeri P.

    1989-04-01

    The literature data on chemiluminescence (CL) in cryogenic matrices have been classified and correlated for the first time. The role of studies on phosphorescence and CL at low temperatures in the development of cryochemistry is shown. The features of low-temperature CL in matrices of nitrogen and inert gases (fine structure of spectra, matrix effects) and the data on the mobility and reactivity of atoms and radicals at very low temperatures are examined. The trends in the development of studies on CL in cryogenic matrices, such as the search for systems involving polyatomic molecules and extending the forms of CL reactions, are followed. The reactions of active nitrogen with hydrocarbons that are accompanied by light emission and CL in the oxidation of carbenes at T >= 77 K are examined. The bibliography includes 112 references.

  16. Enhanced chemiluminescence of the luminol–KMnO4 system by CuO nanosheets and its application for determination of meropenem in water and human serum

    International Nuclear Information System (INIS)

    Khataee, A.R.; Fathinia, M.; Hasanzadeh, A.; Iranifam, M.; Moradkhannejhad, L.

    2014-01-01

    CuO nanosheets were synthesized by an easy and green sonochemical method. It was found that, CuO nanosheets could significantly catalyze the chemiluminescence (CL) reaction of luminol–KMnO 4 in an alkaline condition. Based on this finding, a new CL system (luminol–KMnO 4 –CuO nanosheets) combined with flow injection analysis has been developed for the determination of meropenem for the first time. Moreover, the CL intensity was enhanced when meropenem was presented in the reaction system. Under the optimum conditions, the enhanced CL intensity was proportional to the concentration of meropenem in the ranges of 0.005–6.00 mg L −1 , with a detection limit (3σ) of 0.0036 mg L −1 . The precision of the method was calculated by analyzing samples containing 1.0 mg L −1 meropenem (n=11) and the relative standard deviation (RSD) was 1.7%. Also, a total analysis time per sample was 30 s which confirmed the rapidity of the proposed assay. The practicality of the proposed CL system was evaluated by determining meropenem in spiked environmental water samples and human serum. A discussion on the possible CL reaction mechanism was also presented. - Highlights: • CuO nanosheets (NSs) were successfully prepared by a green sonochemical method. • CuO NSs were found to be an excellent enhancer for luminol−KMnO 4 CL system. • Meropenem was determined using a novel luminol−KMnO 4 −CuO NSs flow injection CL system. • The enhancement mechanism of meropenem on the CL emission was proposed. • Appropriate sensitivity and selectivity were notable features of the proposed method

  17. Eco-friendly synthesis of gelatin-capped bimetallic Au-Ag nanoparticles for chemiluminescence detection of anticancer raloxifene hydrochloride.

    Science.gov (United States)

    Alarfaj, Nawal A; El-Tohamy, Maha F

    2016-09-01

    This study described the utility of green analytical chemistry in the synthesis of gelatin-capped silver, gold and bimetallic gold-silver nanoparticles (NPs). The preparation of nanoparticles was based on the reaction of silver nitrate or chlorauric acid with a 1.0 wt% aqueous gelatin solution at 50°C. The gelatin-capped silver, gold and bimetallic NPs were characterized using transmission electron microscopy, UV-vis, X-ray diffraction and Fourier transform infrared spectroscopy, and were used to enhance a sensitive sequential injection chemiluminescence luminol-potassium ferricyanide system for determination of the anticancer drug raloxifene hydrochloride. The developed method is eco-friendly and sensitive for chemiluminescence detection of the selected drug in its bulk powder, pharmaceutical injections and biosamples. After optimizing the conditions, a linear relationship in the range of 1.0 × 10(-9) to 1.0 × 10(-1)  mol/L was obtained with a limit of detection of 5.0 × 10(-10)  mol/L and a limit of quantification of 1.0 × 10(-9)  mol/L. Statistical treatment and method validation were performed based on ICH guidelines. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Electrochemical Immunosensor for the Detection of Aflatoxin B₁ in Palm Kernel Cake and Feed Samples.

    Science.gov (United States)

    Azri, Farah Asilah; Selamat, Jinap; Sukor, Rashidah

    2017-11-30

    Palm kernel cake (PKC) is the solid residue following oil extraction of palm kernels and useful to fatten animals either as a single feed with only minerals and vitamins supplementation, or mixed with other feedstuffs such as corn kernels or soy beans. The occurrence of mycotoxins (aflatoxins, ochratoxins, zearalenone, and fumonisins) in feed samples affects the animal's health and also serves as a secondary contamination to humans via consumption of eggs, milk and meats. Of these, aflatoxin B₁ (AFB₁) is the most toxically potent and a confirmed carcinogen to both humans and animals. Methods such as High Performance Liquid Chromatography (HPLC) and Liquid Chromatography-Mass Spectrometry (LC-MS/MS) are common in the determination of mycotoxins. However, these methods usually require sample pre-treatment, extensive cleanup and skilled operator. Therefore, in the present work, a rapid method of electrochemical immunosensor for the detection of AFB₁ was developed based on an indirect competitive enzyme-linked immunosorbent assay (ELISA). Multi-walled carbon nanotubes (MWCNT) and chitosan (CS) were used as the electrode modifier for signal enhancement. N -ethyl- N '-(3-dimethylaminopropyl)-carbodiimide (EDC) and N -hydroxysuccinimide (NHS) activated the carboxyl groups at the surface of nanocomposite for the attachment of AFB₁-BSA antigen by covalent bonding. An indirect competitive reaction occurred between AFB₁-BSA and free AFB₁ for the binding site of a fixed amount of anti-AFB₁ antibody. A catalytic signal based on horseradish peroxidase (HRP) in the presence of hydrogen peroxide (H₂O₂) and 3,3',5,5'-tetramethylbenzidine (TMB) mediator was observed as a result of attachment of the secondary antibody to the immunoassay system. As a result, the reduction peak of TMB (Ox) was measured by using differential pulse voltammetry (DPV) analysis. Based on the results, the electrochemical surface area was increased from 0.396 cm² to 1.298 cm² due to the

  19. Towards the use of protein A-tagged gold nanoparticles for signal amplification of electrochemical immunosensors in virus detection

    International Nuclear Information System (INIS)

    Huy Tran, Quang; Thuy Nguyen, Thanh; Chung Pham, Van; Hong Hanh Nguyen, Thi; Tuan Mai, Anh

    2012-01-01

    In this paper we represent a study on the potential use of protein A-tagged gold nanoparticles applied for signal amplification of electrochemical immunosensors. Gold nanoparticles (GNPs) were synthesized by the chemical reduction of tetrachloroauric (III) acid trihydrate using sodium ascorbate, and then tagged with protein A (PrA) via ultracentrifugation. UV-Vis spectroscopy and transmission electron microscopy were used to verify the characteristics of formed GNPs/PrA complex. The analyzed results indicate that GNPs were found spherically, homogeneously, and with an average diameter of about 10 nm. Immunoelectron microscopy was then used to investigate the bioactivity of the GNPs/PrA complex in solution by the effective binding of GNPs to viral particles. Scanning electron and fluorescence microscopies were also used to investigate the distribution and the bioactivity of the GNPs/PrA complex on the surface of the interdigitated sensor. Consequently, this study provided some assumptions of the potential application of protein A-tagged gold nanoparticles for signal amplification of electrochemical immunosensors in virus detection from clinical samples

  20. Electrochemical immunosensor for the determination of insulin-like growth factor-1 using electrodes modified with carbon nanotubes-poly(pyrrole propionic acid) hybrids.

    Science.gov (United States)

    Serafín, V; Agüí, L; Yáñez-Sedeño, P; Pingarrón, J M

    2014-02-15

    An amperometric immunosensor for the determination of the hormone insulin-like growth factor 1 (IGF1) is reported for the first time in this work. As electrochemical transducer, a multiwalled carbon nanotubes-modified glassy carbon electrode on which poly(pyrrole propionic acid) was electropolymerized was prepared. This approach provided a high content of surface confined carboxyl groups suitable for direct covalent binding of anti-IGF1 monoclonal antibody. A sandwich-type immunoassay using a polyclonal antibody labeled with peroxidase, hydrogen peroxide as the enzyme substrate and catechol as redox mediator was employed to monitor the affinity reaction. All the variables involved in the preparation of the modified electrode were optimized and the electrodes were characterized by electrochemical impedance spectroscopy and cyclic voltammetry. Moreover, the different experimental variables affecting the amperometric response of the immunosensor were also optimized. The calibration graph for IGF1 showed a range of linearity extending from 0.5 to 1000 pg/mL, with a detection limit, 0.25 pg/mL, more than 100 times lower than the lowest values reported for the ELISA immunoassays available for IGF1 (30 pg/mL, approximately). Excellent reproducibility for the measurements carried out with different immunosensors and selectivity against other hormones were also evidenced. A commercial human serum spiked with IGF1 at different levels between 0.01 and 10.0 ng/mL was analyzed with good results. © 2013 Elsevier B.V. All rights reserved.

  1. Reaction of uranium (IV) with xenon difluoride by chemiluminescence, spectrophotometric, and spectrofluorimetric methods

    Energy Technology Data Exchange (ETDEWEB)

    Mamykin, A.V.; Kazakov, V.P.

    1988-07-01

    A study is made of the kinetics of the chemiluminescent reaction of oxidation of uranium (IV) by xenon difluoride in 1M HClO/sub 4/ U/sup 4 +/ + XeF/sub 2/ ..-->.. UO/sub 2//sup 2 +/ = h/eta/. The optical density D and the intensity of the photoluminescence of the solution I/sub PL/ were measured in parallel with recording of the luminescence intensity I/sub CL/. I/sub CL/ attains a maximum value some time after the beginning of the reaction, after which it decays exponentially. On the kinetic curves of the time dependence of D and I/sub PL/ an induction period is observed, the extent of which depends on concentrations of reagents and temperature of the solution. The maximum of I/sub CL/ coincides with the end of the induction period if the measurements are carried out under identical conditions. The rate of the reaction after the induction period is described by a first order equation in U/sup (IV)/. The rate constants of the reaction, obtained by chemiluminescence, spectrophotometric, and spectrofluorimetric methods, have close values 2.0 +- 0.4, 1.8 +- 0.3, and 2.1 +- 0.3 sec/sup /minus/1/ x 10/sup 2/, respectively. On the basis of the results obtained, we conclude that the stages of formation of UO/sub 2//sup 2 +/ and of chemiluminescence coincide, i.e., formation of the excited state (UD/sub 2//sup 2 +/) and of chemiluminescence coincide, i.e., formation of the excited state (UD/sub 2//sup 2 +/)* takes place during the reaction. It is proposed and experimentally verified that the reaction passes through an intermediate stage of formation of uranyl ion UO/sub 2//sup +/.

  2. Giant Gold Nanowire Vesicle-Based Colorimetric and SERS Dual-Mode Immunosensor for Ultrasensitive Detection of Vibrio parahemolyticus.

    Science.gov (United States)

    Guo, Zhiyong; Jia, Yaru; Song, Xinxin; Lu, Jing; Lu, Xuefei; Liu, Baoqing; Han, Jiaojiao; Huang, Youju; Zhang, Jiawei; Chen, Tao

    2018-05-15

    Conventional methods for the detection of Vibrio parahemolyticus (VP) usually need tedious, labor-intensive processes, and have low sensitivity, which further limits their practical applications. Herein, we developed a simple and efficient colorimetry and surface-enhanced Raman scattering (SERS) dual-mode immunosensor for sensitive detection of VP, by employing giant Au vesicles with anchored tiny gold nanowires (AuNW) as a smart probe. Due to the larger specific surface and special hollow structure of giant Au vesicles, silver staining would easily lead to vivid color change for colorimetric analysis and further amplify SERS signals. The t-test was further used to determine if two sets of data from colorimetry and SERS were significantly different from each other. The result shows that there was no significant difference between data from the two methods. Two sets of data can mutually validate each other and avoid false positive and negative detection. The designed colorimetry-SERS dual-mode sensor would be very promising in various applications such as food safety inspection, personal healthcare, and on-site environmental monitoring.

  3. Chemiluminescence evidence supporting the selective role of ligands in the permanganate oxidation of micropollutants.

    Science.gov (United States)

    Roderick, Mark S; Adcock, Jacqui L; Terry, Jessica M; Smith, Zoe M; Parry, Samuel; Linton, Stuart M; Thornton, Megan T; Barrow, Colin J; Francis, Paul S

    2013-10-10

    The selective increase in the oxidation rate of certain organic compounds with permanganate in the presence of environmental "ligands" and reduced species has been ascribed to the different reactivity of the target compounds toward Mn(III), which bears striking similarities to recent independent investigations into the use of permanganate as a chemiluminescence reagent. In spite of the importance of Mn(III) in the light-producing pathway, the dependence of the oxidation mechanism for any given compound on this intermediate could not be determined solely through the emission intensity. However, target compounds susceptible to single-electron oxidation by Mn(III) (such as bisphenol A and triclosan) can be easily distinguished by the dramatic increase in chemiluminescence intensity when a permanganate reagent containing high, stable concentrations of Mn(III) is used. The differences are accentuated under the low pH conditions that favor the chemiluminescence emission due to the greater reactivity of Mn(III) and the greater influence of complexing agents. This study supports the previously postulated selective role of ligands and reducing agents in permanganate oxidations and demonstrates a new approach to explore the chemistry of environmental manganese redox processes.

  4. A fluorescent and chemiluminescent difunctional mesoporous silica nanoparticle as a label for the ultrasensitive detection of cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Tao Liang [Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi' an 710062 (China); Song Chaojun; Sun Yuanjie [Department of Immunology, The Fourth Military Medical University, Xi' an 710032 (China); Li Xiaohua; Li Yunyun [Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi' an 710062 (China); Jin Boquan [Department of Immunology, The Fourth Military Medical University, Xi' an 710032 (China); Zhang Zhujun, E-mail: zhangzj@snnu.edu.cn [Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi' an 710062 (China); Yang Kun, E-mail: yangkunkun@fmmu.edu.cn [Department of Immunology, The Fourth Military Medical University, Xi' an 710032 (China)

    2013-01-25

    Highlights: Black-Right-Pointing-Pointer Difunctional amino mesoporous silica nanoparticles (FCMSN) were synthesized. Black-Right-Pointing-Pointer The fluorescence and chemiluminescence properties of the FCMSN were studied. Black-Right-Pointing-Pointer The NaIO{sub 4} oxidation method was used for modification of the FCMSN. Black-Right-Pointing-Pointer Liver cancer 7721 cell was detected. Black-Right-Pointing-Pointer The specificity affected by FCMSN's amino groups was studied. - Abstract: A new kind of ultrabright fluorescent and chemiluminescent difunctional mesoporous silica nanoparticle (FCMSN) is reported. A luminescent dye, Rhodamine 6G or tris(2,2 Prime -bipyridyl)dichlororuthenium(II) hexahydrate (Rubpy), is doped inside nanochannels of a silica matrix. The hydrophobic groups in the silica matrix avoid the leakage of dye from open channels. The amines groups on the surface of the FCMSN improve the modification performance of the nanoparticle. Because the nanochannels are isolated by a network skeleton of silica, fluorescence quenching based on the inner filter effect of the fluorescent dyes immobilized in nanochannels is weakened effectively. The Quantum Yield of obtained 90 nm silica particles was about 61%. Compared with the fluorescent core-shell nanoparticle, the chemiluminescence reagents can freely enter the nanoparticles to react with fluorescent dyes to create chemiluminescence. The results show that the FCMSN are both fluorescent labels and chemiluminescent labels. In biological applications, the NaIO{sub 4} oxidation method was proven to be superior to the glutaraldehyde method. The amount of amino could affect the specificity of the FCMSN. The fluorescence microscopy imaging demonstrated that the FCMSN is viable for biological applications.

  5. Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3

    Directory of Open Access Journals (Sweden)

    Qian-Yun Zhang

    2011-08-01

    Full Text Available Glypican-3 (GPC3 is reported as a great promising tumor marker for hepatocellular carcinoma (HCC diagnosis. Highly sensitive and accurate analysis of serum GPC3 (sGPC3, in combination with or instead of traditional HCC marker alpha-fetoprotein (AFP, is essential for early diagnosis of HCC. Biomaterial-functionalized magnetic particles have been utilized as solid supports with good biological compatibility for sensitive immunoassay. Here, the magnetic nanoparticles (MnPs and magnetic microparticles (MmPs with carboxyl groups were further modified with streptavidin, and applied for the development of chemiluminescence enzyme immunoassay (CLEIA. After comparing between MnPs- and MmPs-based CLEIA, MnPs-based CLEIA was proved to be a better method with less assay time, greater sensitivity, better linearity and longer chemiluminescence platform. MnPs-based CLEIA was applied for detection of sGPC3 in normal liver, hepatocirrhosis, secondary liver cancer and HCC serum samples. The results indicated that sGPC3 was effective in diagnosis of HCC with high performance. Keywords: Magnetic nanoparticle, Magnetic microparticle, Chemiluminescence enzyme immunoassay, Glypican-3, Hepatocellular carcinoma

  6. Chemiluminescence immunoassay for chloramphenicol

    International Nuclear Information System (INIS)

    Lin Si; Xu Wenge; Liu Yibing

    2007-06-01

    A simple, solid-phase chemiluminescence immunoassay (CLIA) for the measurement of Chloramphenicol(CAP) in foodstuffs is described. A rabbit anti-CAP IgG is passively adsorbed onto the walls of polypropylene plates. The labeled conjugant is horseradish peroxidase(HRP) conjugate of CAP. Luminol solution is used as the substrate of HRP. The light yield is inversely proportional to the concentration of CAP. The method has a similar sensitivity (0.05 ng/mL), specificity, precision, and accuracy to a conventional enzyme immunoassay (EIA). The intra-assay and inter-assay CVs of ten samples were <8 and <20%, respectively, and the analytical recovery of the method was 87% 100%. The experimental correlation coefficient of dilution was found to be 0.999 using milk supernatant as buffer. The assay range for the method was 0.1-10 ng/mL, and it displayed good linearity. (authors)

  7. Chemiluminescence measurements as an identification method for gamma-irradiated foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Boegl, W; Heide, L

    1985-01-01

    Samples of 19 different spices, milk powder, whole onions and frozen chicken were exposed to a Co-60 source with radiation doses up to 10/sup 4/ Gy. The subsequent reaction of the irradiated foodstuffs in a luminol solution resulted in light emission (chemiluminescence). This effect can be used as an indicator of radiation treatment.

  8. Tomographic reconstruction of OH* chemiluminescence in two interacting turbulent flames

    International Nuclear Information System (INIS)

    Worth, Nicholas A; Dawson, James R

    2013-01-01

    The tomographic reconstruction of OH* chemiluminescence was performed on two interacting turbulent premixed bluff-body stabilized flames under steady flow conditions and acoustic excitation. These measurements elucidate the complex three-dimensional (3D) vortex–flame interactions which have previously not been accessible. The experiment was performed using a single camera and intensifier, with multiple views acquired by repositioning the camera, permitting calculation of the mean and phase-averaged volumetric OH* distributions. The reconstructed flame structure and phase-averaged dynamics are compared with OH planar laser-induced fluorescence and flame surface density measurements for the first time. The volumetric data revealed that the large-scale vortex–flame structures formed along the shear layers of each flame collide when the two flames meet, resulting in complex 3D flame structures in between the two flames. With a fairly simple experimental setup, it is shown that the tomographic reconstruction of OH* chemiluminescence in forced flames is a powerful tool that can yield important physical insights into large-scale 3D flame dynamics that are important in combustion instability. (paper)

  9. Studies in the reaction dynamics of beam-gas chemiluminescent reactions

    International Nuclear Information System (INIS)

    Prisant, M.G.

    1984-01-01

    This thesis develops techniques for the analysis and interpretation of data obtained from beam-gas chemiluminescence experiments. These techniques are applied to experimental studies of atom transfer reactions of the type A + BC → AB + C. A procedure is developed for determining the product rotational alignment in the center-of-mass frame from polarization measurements of chemiluminescent atom-diatom exchange reactions under beam-gas conditions. Knowledge of a vector property of a reaction, such as product alignment, provides information on the disposition of angular momentum by a chemical reaction. Fluorescence polarization and hence product alignment are measured for two prototype reactions. The reaction of metastable calcium atoms with hydrogen-chloride gas yields highly aligned calcium-chloride product which exhibits little variation of alignment with vibrational state. The reaction of ground-state calcium with fluorine gas yields moderately aligned product which shows strong variation of alignment with vibration. A multi-surface direct-interaction model is developed to interpret product alignment and population data. The predictions of this model for the reaction of calcium with fluorine show reasonable agreement with experiment

  10. Chemiluminescence of curcumin and quenching effect of dimethyl sulfoxide on its peroxyoxalate system

    Energy Technology Data Exchange (ETDEWEB)

    Yari, Abdollah, E-mail: a.yari@ymail.co [Lorestan University, Department of Chemistry, Flakalaflak Street, 68178-17133 Khorramabad (Iran, Islamic Republic of); Saidikhah, Marzieh [Lorestan University, Department of Chemistry, Flakalaflak Street, 68178-17133 Khorramabad (Iran, Islamic Republic of)

    2010-04-15

    The chemiluminescence behavior of the reaction between bis(2,4,6-trichlorophenyl)oxalate (TCPO) and hydrogen peroxide, in the presence of curcumin as fluorophore, has been investigated. Experimental factors such as TCPO, sodium salicylate (SS), hydrogen peroxide and curcumin concentration were optimized. The chemiluminescence signal showed a linear decay while dimethyl sulfoxide (DMSO) was added to the peroxyoxalate (PO-CL) system. The reaction resulted in a Stern-Volmer plot with a K{sub q} value of 7.3x10{sup 4}. The evaluated lower and upper detection limits of measurable concentrations of DMSO are 3.50x10{sup -5} and 1.53x10{sup -4} M, respectively. The PO-CL parameters were estimated by computer fitting of the experimental CL intensity to proper models.

  11. Atrazine analysis using an amperometric immunosensor based on single-chain antibody fragments and regeneration-free multi-calibrant measurement

    International Nuclear Information System (INIS)

    Grennan, Kathleen; Strachan, Gillian; Porter, Andrew J.; Killard, Anthony J.; Smyth, Malcolm R.

    2003-01-01

    This work describes the development of an electrochemical immunosensor for the analysis of atrazine using recombinant single-chain antibody (scAb) fragments. The sensors are based on carbon paste screen-printed electrodes incorporating the conducting polymer polyaniline (PANI)/poly(vinylsulphonic acid) (PVSA), which enables direct mediatorless coupling to take place between the redox centres of antigen-labelled horseradish peroxidase (HRP) and the electrode surface. Competitive immunoassays can be performed in real-time using this separation-free system. Analytical measurements based on the pseudo-linear relationship between the slope of a real-time amperometric signal and the concentration of analyte, yield a novel immunosensor set-up capable of regenerationless amperometric analysis. Multiple, sequential measurements of standards and samples can be performed on a single scAb-modified surface in a matter of minutes. No separation of bound and unbound species was necessary prior to detection. The system is capable of measuring atrazine to a detection limit of 0.1 ppb (0.1 μg l -1 ). This system offers the potential for rapid, cost-effective immunosensing for the analysis of samples of environmental, medical and pharmaceutical significance

  12. Reagentless chemiluminescence-based fiber optic sensors for regenerative life support in space

    Science.gov (United States)

    Atwater, James E.; Akse, James R.; DeHart, Jeffrey; Wheeler, Richard R., Jr.

    1995-04-01

    The initial feasibility demonstration of a reagentless chemiluminescence based fiber optic sensor technology for use in advanced regenerative life support applications in space and planetary outposts is described. The primary constraints for extraterrestrial deployment of any technology are compatibility with microgravity and hypogravity environments; minimal size, weight, and power consumption; and minimal use of expendables due to the great expense and difficulty inherent to resupply logistics. In the current research, we report the integration of solid state flow through modules for the production of aqueous phase reagents into an integrated system for the detection of important analytes by chemiluminescence, with fiber optic light transmission. By minimizing the need for resupply expendables, the use of solid phase modules makes complex chemical detection schemes practical. For the proof of concept, hydrogen peroxide and glucose were chosen as analytes. The reaction is catalyzed by glucose oxidase, an immobilized enzyme. The aqueous phase chemistry required for sensor operation is implemented using solid phase modules which adjust the pH of the influent stream, catalyze the oxidation of analyte, and provide the controlled addition of the luminophore to the flowing aqueous stream. Precise control of the pH has proven essential for the long-term sustained release of the luminophore. Electrocatalysis is achieved using a controlled potential across gold mesh and gold foil electrodes which undergo periodic polarity reversals. The development and initial characterization of performance of the reagentless fiber optic chemiluminescence sensors are presented in this paper.

  13. A turn-on chemiluminescence biosensor for selective and sensitive detection of adenosine based on HKUST-1 and QDs-luminol-aptamer conjugates.

    Science.gov (United States)

    Lin, Yanna; Dai, Yuxue; Sun, Yuanling; Ding, Chaofan; Sun, Weiyan; Zhu, Xiaodong; Liu, Hao; Luo, Chuannan

    2018-05-15

    In this work, HKUST-1 and QDs-luminol-aptamer conjugates were prepared. The QDs-luminol-aptamer conjugates can be adsorbed by graphene oxide through π-π conjugation. When the adenosine was added, the QDs-luminol-aptamer conjugates were released from magnetic graphene oxide (MGO), the chemiluminescent switch was turned on. It was reported that HKUST-1 can catalyze the chemiluminescence reaction of luminol-H 2 O 2 system in an alkaline medium, and improve the chemiluminescence resonance energy transfer (CRET) between chemiluminescence and QDs indirectly. Thus, the adenosine can be detected sensitively. Based on this phenomenon, the excellent platform for detection of adenosine was established. Under the optimized conditions, the linear detection range for adenosine was 1.0 × 10 -12 -2.2 × 10 -10 mol/L with a detection limit of 2.1 × 10 -13 mol/L. The proposed method was successfully used for adenosine detection in biological samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Significance of isolated reactive treponemal chemiluminescence immunoassay results.

    Science.gov (United States)

    Hunter, Michael G; Robertson, Peter W; Post, Jeffrey J

    2013-05-01

    Isolated reactive serum treponemal chemiluminescence immunoassay (CIA) specimens cause clinical uncertainty. Sera were screened by CIA, and reactive samples underwent reflex testing with rapid plasma reagin (RPR), Treponema pallidum particle agglutination (TPPA), and fluorescent treponemal antibody absorption (FTA Abs) assays. Samples reactive only on the CIA were deemed "isolated" reactive CIA samples. We undertook detailed review of a subset of subjects with isolated reactive CIA specimens. Of 28 261 specimens, 1171 (4.1%) were reactive on CIA, of which 133 (11.3%) had isolated CIA reactivity. Most subjects (66 of 82 [80.5%]) with isolated reactive CIA specimens were from high-prevalence populations. We found evidence of CIA, TPPA, and FTA Abs seroreversion. The median chemiluminescent signal-to-cutoff ratio was similar for isolated reactive CIA sera and sera that were reactive on either FTA Abs or TPPA assays (2.19 vs 2.32; P = .15) but lower than for sera reactive on both FTA Abs and TPPA assays (12.37; P < .001) or for sera reactive on RPR assays (25.53; P < .001). A total of 11 of 20 patients (55%) with an isolated reactive CIA specimen who underwent medical record review had previous or subsequent evidence of syphilis infection. Isolated reactive CIA specimens may represent true T. pallidum infection and may be found after seroreversion of traditional treponemal assays.

  15. Differentiating between intra- and extracellular chemiluminescence in diluted whole-blood samples

    Czech Academy of Sciences Publication Activity Database

    Rájecký, Michal; Lojek, Antonín; Číž, Milan

    2012-01-01

    Roč. 34, č. 2 (2012), s. 136-142 ISSN 1751-5521 R&D Projects: GA MŠk(CZ) OC10044 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : chemiluminescence * isoluminol * whole blood Subject RIV: BO - Biophysics Impact factor: 1.293, year: 2012

  16. New approach for monitoring fish stress: A novel enzyme-functionalized label-free immunosensor system for detecting cortisol levels in fish.

    Science.gov (United States)

    Wu, Haiyun; Ohnuki, Hitoshi; Ota, Shirei; Murata, Masataka; Yoshiura, Yasutoshi; Endo, Hideaki

    2017-07-15

    Fishes display a wide variation in their physiological responses to stress, which is clearly evident in the plasma corticosteroid changes, chiefly cortisol levels in fish. As a well-known indicator of fish stress, a simple and rapid method for detecting cortisol changes especially sudden increases is desired. In this study, we describe an enzyme-functionalized label-free immunosensor system for detecting fish cortisol levels. Detection of cortisol using amperometry was achieved by immobilizing both anti-cortisol antibody (selective detection of cortisol) and glucose oxidase (signal amplification and non-toxic measurement) on an Au electrode surface with a self-assembled monolayer. This system is based on the maximum glucose oxidation output current change induced by the generation of a non-conductive antigen-antibody complex, which depends on the levels of cortisol in the sample. The immunosensor responded to cortisol levels with a linear decrease in the current in the range of 1.25-200ngml -1 (R=0.964). Since the dynamic range of the sensor can cover the normal range of plasma cortisol in fish, the samples obtained from the fish did not need to be diluted. Further, electrochemical measurement of one sample required only ~30min. The sensor system was applied to determine the cortisol levels in plasma sampled from Nile tilapia (Oreochromis niloticus), which were then compared with levels of the same samples determined using the conventional method (ELISA). Values determined using both methods were well correlated. These findings suggest that the proposed label-free immunosensor could be useful for rapid and convenient analysis of cortisol levels in fish without sample dilution. We also believe that the proposed system could be integrated in a miniaturized potentiostat for point-of-care cortisol detection and useful as a portable diagnostic in fish farms in the future. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Phenylboronic acid immunoaffinity reactor coupled with flow injection chemiluminescence for determination of {alpha}-fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Wu Yafeng [Jiangsu Provincial Key Lab of Biomaterials and Biodevices, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210096 (China); Zhuang Yafeng [Department of Chemistry, Changzhou Institute of Technology, Changzhou 213022 (China); Liu Songqin [Jiangsu Provincial Key Lab of Biomaterials and Biodevices, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210096 (China)], E-mail: liusq@seu.edu.cn; He Lin [Department of Chemistry, North Carolina State University, Raleigh, NC 27695-8204 (United States)

    2008-12-23

    A reusable and sensitive immunoassay based on phenylboronic acid immunoaffinity reactor in combination with flow injection chemiluminescence (CL) for determination of glycoprotein was described. The reactor was fabricated by immobilizing 3-aminophenylboronic acid (APBA) on glass microbeads with {gamma}-glycidoxypropyltrimethoxysilane (GPMS) as linkage. The {alpha}-fetoprotein (AFP) could be easily immobilized on the APBA coated beads through sugar-boronic interaction. After an off-line incubation, the mixture of the analyte AFP with horseradish peroxidase-labeled AFP antibody (HRP-anti-AFP) was injected into the reactor. This led the trapping of free HRP-anti-AFP by the surface coated AFP on glass beads. The trapped HRP-anti-AFP was detected by chemiluminescence due to its sensitizing effect on the reaction of luminol and hydrogen peroxide. Under optimal conditions, the chemiluminescent signal was proportional to AFP concentration in the range of 10-100 ng mL{sup -1}. The whole assay process including regeneration of the reactor could be completed within 31 min. The proposed system showed acceptable detection and fabrication reproducibility, and the results obtained with the present method were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. The described method enabled a low-cost, time saving and was potential to detect the serum AFP level in clinical diagnosis.

  18. Rayleigh SAW-Assisted SH-SAW Immunosensor on X-Cut 148-Y LiTaO3.

    Science.gov (United States)

    Kogai, Takashi; Yatsuda, Hiromi; Kondoh, Jun

    2017-09-01

    In this paper, we describe a shear horizontal surface acoustic wave (SH-SAW) immunosensor that utilizes induce agitation by a Rayleigh SAW (R-SAW) on an X-cut 148-Y LiTaO 3 substrate. On this substrate, SH-SAWs and R-SAWs with different frequencies can be effectively generated at an interdigital transducer (IDT). First, to consider the power flow angles of SH-SAWs and R-SAWs on this substrate, the 360-MHz delay lines with six different tilt angles were designed and fabricated. From the experiments, an optimal power flow angle of 9° for the SH-SAW on this substrate is obtained. Second, in order to consider the immunoreactions of the SH-SAW immunosensors, a delay line with a tilt angle of 9° was designed and fabricated on this substrate. The delay line, which can generate two SAWs, namely, a 100-MHz SH-SAW and an 88.8-MHz R-SAW, has a propagation area covered with antigens of human serum albumin between transmitting and receiving IDTs. The immunoreactions caused by antigen-antibody binding events on the surface of the delay line were investigated on the basis of the velocity changes of the SH-SAWs for sensing with and without the assistance of an R-SAW. As a result, it was confirmed that the SH-SAW velocity changes due to antigen-antibody reactions can be markedly increased by the assistance of R-SAW agitation.

  19. Agent orange herbicides, organophosphate and triazinic pesticides analysis in olive oil and industrial oil mill waste effluents using new organic phase immunosensors.

    Science.gov (United States)

    Martini, Elisabetta; Merola, Giovanni; Tomassetti, Mauro; Campanella, Luigi

    2015-02-15

    New immunosensors working in organic solvent mixtures (OPIEs) for the analysis of traces of different pesticides (triazinic, organophosphates and chlorurates) present in hydrophobic matrices such as olive oil were developed and tested. A Clark electrode was used as transducer and peroxidase enzyme as marker. The competitive process took place in a chloroform-hexane 50% (V/V) mixture, while the subsequent enzymatic final measurement was performed in decane and using tert-butylhydroperoxide as substrate of the enzymatic reaction. A linear response of between about 10nM and 5.0μM was usually obtained in the presence of olive oil. Recovery tests were carried out in commercial or artisanal extra virgin olive oil. Traces of pesticides were also checked in the oily matrix, in pomace and mill wastewaters from an industrial oil mill. Immunosensors show good selectivity and satisfactory precision and recovery tests performed in olive oil gave excellent results. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Off-line phase-averaged particle image velocimetry and OH chemiluminescence measurements using acoustic time series

    International Nuclear Information System (INIS)

    Fischer, A; Bake, F; Heinze, J; Willert, C; Diers, O; Röhle, I

    2009-01-01

    In order to analyze unsteady flow phenomena in combustion facilities two phase-sorting methods have been developed and investigated for the retrieval of phase-resolved data from (randomly) sampled 'single-shot' data such as PIV recordings or chemiluminescence imagery in a post-processing step. This is made possible by simultaneously recorded continuous time traces of reference data (e.g., pressure signal). Using this off-line method synchronous phase-locked PIV and OH chemiluminescence visualizations could be recovered from data obtained in two different combustion facilities. This paper also presents some of the theoretical background necessary for the application of two different phase-sorting algorithms

  1. Enhanced electrogenerated chemiluminescence of Ru(bpy){sub 3}{sup 2+}/TPrA (bpy=2,2'-bipyridine; TPrA=tri-n-propylamine) via oxygen quenching using melatonin

    Energy Technology Data Exchange (ETDEWEB)

    Witt, Maria D.; Roughton, Sarah; Isakson, Timothy J.; Richter, Mark M., E-mail: markrichter@missouristate.edu

    2016-03-15

    The effect on the electrogenerated chemiluminescence (ECL) of the Ru(bpy){sub 3}{sup 2+}/TPrA (bpy=2,2'-bipyridine; TPra=tri-n-propylamine) system when melatonin (N-acetyl-5-methoxytryptamine; MLT) and structurally related compounds (e.g., D- and L-Tryptophan (TRY), 7-Azatryptophan (7-AZA) and Serotonin (SER)) are present in aqueous buffered solution is reported. MLT, D- and L-TRY, SER and 7-AZA display weak intrinsic ECL when TPrA is used as an oxidative–reductive coreactant. However, micromolar concentrations of melatonin result in up to 2.5-fold enhancement of Ru(bpy){sub 3}{sup 2+}/TPrA ECL while the other analytes attenuate ECL between 2- and 1000-fold. Photoluminescence (PL) emission efficiencies do not change in the presence of melatonin unless the melatonin solution has undergone electrochemical bulk oxidation, at which point PL and ECL are nearly indistinguishable. Spectroscopic, electrochemical and spectroelectrochemical studies indicate that the mechanism involves oxygen scavenging by melatonin oxidation products. This scavenging prevents the quenching of the {sup *}Ru(bpy){sub 3}{sup 2+} excited states by dissolved oxygen in solution. Melatonin can be coupled with 30% by volume 2,2,2-trifluorethanol (TFE) or with the nonionic surfactant Triton X-100 (polyethylene glycol tert-octylphenyl ether) for even greater enhancement of Ru(bpy){sub 3}{sup 2+}/TPrA ECL.

  2. SPR based immunosensor for detection of Legionella pneumophila in water samples

    Science.gov (United States)

    Enrico, De Lorenzis; Manera, Maria G.; Montagna, Giovanni; Cimaglia, Fabio; Chiesa, Maurizio; Poltronieri, Palmiro; Santino, Angelo; Rella, Roberto

    2013-05-01

    Detection of legionellae by water sampling is an important factor in epidemiological investigations of Legionnaires' disease and its prevention. To avoid labor-intensive problems with conventional methods, an alternative, highly sensitive and simple method is proposed for detecting L. pneumophila in aqueous samples. A compact Surface Plasmon Resonance (SPR) instrumentation prototype, provided with proper microfluidics tools, is built. The developed immunosensor is capable of dynamically following the binding between antigens and the corresponding antibody molecules immobilized on the SPR sensor surface. A proper immobilization strategy is used in this work that makes use of an important efficient step aimed at the orientation of antibodies onto the sensor surface. The feasibility of the integration of SPR-based biosensing setups with microfluidic technologies, resulting in a low-cost and portable biosensor is demonstrated.

  3. Amperometric carbohydrate antigen 19-9 immunosensor based on three dimensional ordered macroporous magnetic Au film coupling direct electrochemistry of horseradish peroxidase

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qi [College of Sciences, Nanjing Tech University, Nanjing 211816 (China); Chen, Xiaojun, E-mail: chenxj_njut@126.com [College of Sciences, Nanjing Tech University, Nanjing 211816 (China); State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing 210009 (China); Tang, Yin [Zhangjiagang Hospital of Traditional Chinese Medicine, Zhangjiagang 215600 (China); Ge, Lingna; Guo, Buhua [College of Sciences, Nanjing Tech University, Nanjing 211816 (China); Yao, Cheng, E-mail: yaochengnjut@163.com [College of Sciences, Nanjing Tech University, Nanjing 211816 (China)

    2014-03-01

    Highlights: • Three dimensional ordered macroporous magnetic electrode was newly used in electrochemical immunosensor. • The large surface area of macroporous magnetic electrode could improve the immobilized amount of antibody. • Au nanoparticles functionalized SBA-15 was used to immobilize enzyme labeled Ab₂ and enzyme. • Macroporous magnetic electrode and Au nanoparticles composite facilitated the direct electron transfer of enzyme. • The immunoassay avoided adding electron transfer mediator, simplifying the procedure. Abstract: A sandwich-type electrochemical immunosensor for the detection of carbohydrate antigen 19-9 (CA 19-9) antigen based on the immobilization of primary antibody (Ab₁) on three dimensional ordered macroporous magnetic (3DOMM) electrode, and the direct electrochemistry of horseradish peroxidase (HRP) that was used as both the label of secondary antibody (Ab₂) and the blocking reagent. The 3DOMM electrode was fabricated by introducing core–shell Au–SiO₂@Fe₃O₄ nanospheres onto the surface of three dimensional ordered macroporous (3DOM) Au electrode via the application of an external magnet. Au nanoparticles functionalized SBA-15 (Au@SBA-15) was conjugated to the HRP labeled secondary antibody (HRP-Ab₂) through the Au–SH or Au–NH₃⁺ interaction, and HRP was also used as the block reagent. The formation of antigen–antibody complex made the combination of Au@SBA-15 and 3DOMM exhibit remarkable synergistic effects for accelerating direct electron transfer (DET) between HRP and the electrode. Under the optimal conditions, the DET current signal increased proportionally to CA 19-9 concentration in the range of 0.05 to 15.65 U mL⁻¹ with a detection limit of 0.01 U mL⁻¹. Moreover, the immunosensor showed high selectivity, good stability, satisfactory reproducibility and regeneration. Importantly, the developed method was used to assay clinical serum specimens, achieving a good relation with those obtained from

  4. Negative interference by rheumatoid factor in alpha-fetoprotein chemiluminescent microparticle immunoassay.

    Science.gov (United States)

    Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong

    2017-01-01

    Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime

  5. The chemiluminescence of luminol in aqueous solutions, a pulse radiolytic study

    International Nuclear Information System (INIS)

    Lind, J.

    1980-01-01

    The mechanism of chemiluminescence was studied when the luminol radical and superoxide were generated simultaneously. Hydroperoxide was formed at the first reaction step with a pKa value between 11 and 12. The dissociated form was found to undergo a monomolecular reaction leading to light generation and having a rate constant > 2 x 10 5 s -1 . The protonated form had the rate constant of approx. 2000 s -1 and formed a product which absorbed around 390 nm without light emission. The reaction of the two-electron oxidation product of luminol, 5-aminophthalazine-1, 4 dione (azaquinone), with hydrogenperoxide was stoichiometrically equivalent to the recombination of superoxide with the luminol radical. The pulseradiolytic generation of the chlorinedioxide radical ClO 2 in aqueous solution of sodium chlorite is described, and the oxidation of luminol by ClO 2 in two steps is reported: 1. Radical adducts are formed. 2. The reaction of ClO 2 x radical with the adduct to form azaquinone. The chemiluminescent reaction between the azaquinone and hydrogenperoxide consists of a second order reaction between HO 2 and the azaquinone to form a hydroperoxide followed by a monomolecular rearrangement of the dissociated form of the latter. Its acidbase equilibrium has a pKa of 10.6. A nitrogencentered structure is ascribed to the hydroperoxide formed by cross-recombination of the luminolradical and superoxide while the reaction between HO 2 and azaquinone yields a carboncentered hydroperoxide. The existence of two different emitters is evidenced by the following observations. 1. A slight difference in chemiluminescence spectra. 2. The formation of an endproduct with pKa approx. 10.2 in the luminolradical superoxide system. 3. The formation of an endproduct which acts as an efficient radial scavenger in the luminol radical superoxide system. (G.B.)

  6. Fabrication of a Novel Highly Sensitive and Selective Immunosensor for Botulinum Neurotoxin Serotype A Based on an Effective Platform of Electrosynthesized Gold Nanodendrites/Chitosan Nanoparticles

    Directory of Open Access Journals (Sweden)

    Rahim Sorouri

    2017-05-01

    Full Text Available In this work, a novel nanocomposite consisting of electrosynthesized gold nanodendrites and chitosan nanoparticles (AuNDs/CSNPs has been prepared to fabricate an impedimetric immunosensor based on a screen printed carbon electrode (SPCE for the rapid and sensitive immunoassay of botulinum neurotoxin A (BoNT/A. BoNT/A polyclonal antibody was immobilized on the nanocomposite-modified SPCE for the signal amplification. The structure of the prepared nanocomposite was investigated by transmission electron microscopy (TEM, scanning electron microscopy (SEM, X-ray diffraction (XRD, Fourier transform infrared (FTIR spectroscopy, cyclic voltammetry (CV, and electrochemical impedance spectroscopy (EIS. The charge transfer resistance (RCT changes were used to detect BoNT/A as the specific immuno-interactions at the immunosensor surface that efficiently limited the electron transfer of Fe(CN63−/4− as a redox probe at pH = 7.4. A linear relationship was observed between the %∆RCT and the concentration logarithm of BoNT/A within the range of 0.2 to 230 pg·mL−1 with a detection limit (S/N = 3 of 0.15 pg·mL−1. The practical applicability of the proposed sensor was examined by evaluating the detection of BoNT/A in milk and serum samples with satisfactory recoveries. Therefore, the prepared immunosensor holds great promise for the fast, simple and sensitive detection of BoNT/A in various real samples.

  7. Chemiluminescence from the reaction of Ba 3D with nitric oxide

    International Nuclear Information System (INIS)

    Johnson, S.A.; Solarz, R.W.; Dubrin, J.W.; Brotzmann, R.

    1977-01-01

    The reaction of laser excited Ba*( 3 D) states with nitric oxide is presented. BaO product is not detected, although the channel is thermodynamically open, and instead chemiluminescence is observed. Experiments which suggest that radiative recombination, Ba + NO → BaNO* → BaNO, is the observed reaction channel will also be presented

  8. Improvement of Accuracy in Flow Immunosensor System by Introduction of Poly-2-[3-(methacryloylaminopropylammonio]ethyl 3-aminopropyl Phosphate

    Directory of Open Access Journals (Sweden)

    Yusuke Fuchiwaki

    2011-01-01

    Full Text Available In order to improve the accuracy of immunosensor systems, poly-2-[3-(methacryloylaminopropylammonio]ethyl 3-aminopropyl phosphate (poly-3MAm3AP, which includes both phosphorylcholine and amino groups, was synthesized and applied to the preparation of antibody-immobilized beads. Acting as an antibody-immobilizing material, poly-3MAm3AP is expected to significantly lower nonspecific adsorption due to the presence of the phosphorylcholine group and recognize large numbers of analytes due to the increase in antibody-immobilizing sites. The elimination of nonspecific adsorption was compared between the formation of a blocking layer on antibody-immobilized beads and the introduction of a material to combine antibody with beads. Determination with specific and nonspecific antibodies was then investigated for the estimation of signal-to-noise ratio. Signal intensities with superior signal-to-noise ratios were obtained when poly-3MAm3AP was introduced. This may be due to the increase in antibody-immobilizing sites and the extended space for antigen-antibody interaction resulting from the electrostatic repulsion of poly-3MAm3AP. Thus, the application of poly-3MAm3AP coatings to immunoassay beads was able to improve the accuracy of flow immunosensor systems.

  9. Radiation effects on chemiluminescence of resting and immunologically activated alveolar macrophages

    International Nuclear Information System (INIS)

    Benichou, G.; Dormont, D.; Herodin, F.; Pasquier, C.; Hopital Saint Antoine, 75 - Paris

    1986-01-01

    In resting cells, for low radiation doses, a transient activation of chemiluminescence was observed, maximal at 3 Gy. At 10 Gy, CL returned to the control value; greater doses (above 30 Gy) induced a progressive diminution of the response which was abolished at 100 Gy. Activated alveolar macrophages showed a 30% decrease of the chemiluminescence at 10 Gy. The respiratory burst induced by opsonized zymosan was abolished at 30 Gy. IgG anti-MHC(IgGαB 1 ) activated specifically the GP S2 alveolar macrophages by alloantibody bipolar bridging; by contrast IgG which are directed against non-specific allogeneic determinants (IgG α B 3 ) or specific F(ab') 2 (F(ab') 2 αB 1 ) are unable to stimulate the cells. For all the tested doses, irradiation had no effect on this activation mechanism. The results with the three doses tested (3 Gy, 10 Gy, 30 Gy) are comparable to those using the positive control cells. The same results are obtained with the class II antigens and their specific IgG. (UK)

  10. A Novel Technique for Generating and Observing Chemiluminescence in a Biological Setting

    KAUST Repository

    Büchel, Gabriel E.

    2017-03-10

    Intraoperative imaging techniques have the potential to make surgical interventions safer and more effective; for these reasons, such techniques are quickly moving into the operating room. Here, we present a new approach that utilizes a technique not yet explored for intraoperative imaging: chemiluminescent imaging. This method employs a ruthenium-based chemiluminescent reporter along with a custom-built nebulizing system to produce ex vivo or in vivo images with high signal-to-noise ratios. The ruthenium-based reporter produces light following exposure to an aqueous oxidizing solution and re-reduction within the surrounding tissue. This method has allowed us to detect reporter concentrations as low as 6.9 pmol/cm(2). In this work, we present a visual guide to our proof-of-concept in vivo studies involving subdermal and intravenous injections in mice. The results suggest that this technology is a promising candidate for further preclinical research and might ultimately become a useful tool in the operating room.

  11. Electrogenerated chemiluminescence of luminol using low-cost electrodes

    International Nuclear Information System (INIS)

    Salgado, Guillermo; Navarrete, Jose; Bustos, Carlos; Sanchez, Cristian; Ugarte, Ricardo

    2006-01-01

    The purpose of the study was to observe eletrogenerated chemiluminescence (ECL) of luminol using different materials as electrodes such as wires, nails, coins, razor blades, etc. Based on the experimental observations and the mechanisms proposed in the literature, students should be capable of analyzing their results in order to understand the phenomena studied. Students could then elaborate a mechanism of action consistent with the experimental results which could rationalize the formation of intermediates in the reaction and the dependence of ECL on solution pH in addition to other points of interest. (author)

  12. Molecularly imprinted polymer based on chemiluminescence imaging for the chiral recognition of dansyl-phenylalanine.

    Science.gov (United States)

    Wang, Li; Zhang, Zhujun; Huang, Lianggao

    2008-03-01

    A new molecularly imprinted polymer (MIP)-chemiluminescence (CL) imaging detection approach towards chiral recognition of dansyl-phenylalanine (Phe) is presented. The polymer microspheres were synthesized using precipitation polymerization with dansyl-L-Phe as template. Polymer microspheres were immobilized in microtiter plates (96 wells) using poly(vinyl alcohol) (PVA) as glue. The analyte was selectively adsorbed on the MIP microspheres. After washing, the bound fraction was quantified based on peroxyoxalate chemiluminescence (PO-CL) analysis. In the presence of dansyl-Phe, bis(2,4,6-trichlorophenyl)oxalate (TCPO) reacted with hydrogen peroxide (H2O2) to emit chemiluminescence. The signal was detected and quantified with a highly sensitive cooled charge-coupled device (CCD). Influencing factors were investigated and optimized in detail. Control experiments using capillary electrophoresis showed that there was no significant difference between the proposed method and the control method at a confidence level of 95%. The method can perform 96 independent measurements simultaneously in 30 min and the limits of detection (LODs) for dansyl-L-Phe and dansyl-D-Phe were 0.025 micromol L(-1) and 0.075 micromol L(-1) (3sigma), respectively. The relative standard deviation (RSD) for 11 parallel measurements of dansyl-L-Phe (0.78 micromol L(-1)) was 8%. The results show that MIP-based CL imaging can become a useful analytical technology for quick chiral recognition.

  13. Direct current-induced electrogenerated chemiluminescence of hydrated and chelated Tb(III) at aluminum cathodes

    International Nuclear Information System (INIS)

    Hakansson, M.; Jiang, Q.; Spehar, A.-M.; Suomi, J.; Kotiranta, M.; Kulmala, S.

    2005-01-01

    Cathodic DC polarization of oxide-covered aluminum produces electrogenerated chemiluminescence from hydrated and chelated Tb(III) ions in aqueous electrolyte solutions. At the moment of cathodic voltage onset, a strong cathodic flash is observed, which is attributed to a tunnel emission of hot electrons into the aqueous electrolyte solution and the successive chemical reactions with the luminophores. However, within a few milliseconds the insulating oxide film is damaged and finally dissolved due to (i) indiffusion of protons or alkali metal ions into the thin oxide film, (ii) subsequent hydrogen evolution at the aluminum/oxide interface and (iii) alkalization of the electrode surface induced by hydrogen evolution reaction. When the alkalization of the electrode surface has proceeded sufficiently, chemiluminescence is generated with increasing intensity. Aluminum metal, short-lived Al(II), Al(I) or atomic hydrogen and its conjugated base form, hydrated electron, can act as highly reducing species in addition to the less energetic heterogeneously transferred electrons from the aluminum electrode. Tb(III) added as a hydrated ion in the solution probably luminesces in the form of Tb(OH) 3 or Tb(OH) 4 - by direct redox reactions of the central ion whereas multidentate aromatic ligand chelated Tb(III) probably luminesces by ligand sensitized chemiluminescence mechanism in which ligand is first excited by one-electron redox reactions, which is followed by intramolecular energy transfer to the central ion which finally emits light

  14. Soot and chemiluminescence in diesel combustion of bio-derived, oxygenated and reference fuels

    NARCIS (Netherlands)

    Klein-Douwel, R.J.H.; Donkerbroek, A.J.; Vliet, A.P. van; Boot, M.D.; Somers, L.M.T.; Baert, R.S.G.; Dam, N.J.; Meulen, J.J. ter

    2009-01-01

    High-speed imaging, spectroscopy and thermodynamical characterization are applied to an optically accessible, heavy-duty diesel engine in order to compare sooting and chemiluminescence behaviour of bio-derived, oxygenated fuels and various reference fuels. The fuels concerned include the bio-derived

  15. Label-free electrochemical immunosensor for the carcinoembryonic antigen using a glassy carbon electrode modified with electrodeposited Prussian Blue, a graphene and carbon nanotube assembly and an antibody immobilized on gold nanoparticles

    International Nuclear Information System (INIS)

    Feng, Dexiang; Lu, Xiaocui; Dong, Xiao; Zhang, Yuzhong; Ling, Yunyun

    2013-01-01

    We described a sensitive, label-free electrochemical immunosensor for the detection of carcinoembryonic antigen. It is based on the use of a glassy carbon electrode (GCE) modified with a multi-layer films made from Prussian Blue (PB), graphene and carbon nanotubes by electrodeposition and assembling techniques. Gold nanoparticles were electrostatically absorbed on the surface of the film and used for the immobilization of antibody, while PB acts as signaling molecule. The stepwise assembly process was investigated by differential pulse voltammetry and scanning electron microscopy. It is found that the formation of antibody-antigen complexes partially inhibits the electron transfer of PB and decreased its peak current. Under the optimal conditions, the decrease of intensity of the peak current of PB is linearly related to the concentration of carcinoembryonic antigen in two ranges (0.2–1.0, and 1.0–40.0 ng·mL −1 ), with a detection limit of 60 pg·mL −1 (S/N = 3). The immunosensor was applied to analyze five clinical samples, and the results obtained were in agreement with clinical data. In addition, the immunosensor exhibited good precision, acceptable stability and reproducibility. (author)

  16. Electrochemical Immunosensor for the Detection of Aflatoxin B1 in Palm Kernel Cake and Feed Samples

    Directory of Open Access Journals (Sweden)

    Farah Asilah Azri

    2017-11-01

    Full Text Available Palm kernel cake (PKC is the solid residue following oil extraction of palm kernels and useful to fatten animals either as a single feed with only minerals and vitamins supplementation, or mixed with other feedstuffs such as corn kernels or soy beans. The occurrence of mycotoxins (aflatoxins, ochratoxins, zearalenone, and fumonisins in feed samples affects the animal’s health and also serves as a secondary contamination to humans via consumption of eggs, milk and meats. Of these, aflatoxin B1 (AFB1 is the most toxically potent and a confirmed carcinogen to both humans and animals. Methods such as High Performance Liquid Chromatography (HPLC and Liquid Chromatography–Mass Spectrometry (LC-MS/MS are common in the determination of mycotoxins. However, these methods usually require sample pre-treatment, extensive cleanup and skilled operator. Therefore, in the present work, a rapid method of electrochemical immunosensor for the detection of AFB1 was developed based on an indirect competitive enzyme-linked immunosorbent assay (ELISA. Multi-walled carbon nanotubes (MWCNT and chitosan (CS were used as the electrode modifier for signal enhancement. N-ethyl-N′-(3-dimethylaminopropyl-carbodiimide (EDC and N-hydroxysuccinimide (NHS activated the carboxyl groups at the surface of nanocomposite for the attachment of AFB1-BSA antigen by covalent bonding. An indirect competitive reaction occurred between AFB1-BSA and free AFB1 for the binding site of a fixed amount of anti-AFB1 antibody. A catalytic signal based on horseradish peroxidase (HRP in the presence of hydrogen peroxide (H2O2 and 3,3′,5,5′-tetramethylbenzidine (TMB mediator was observed as a result of attachment of the secondary antibody to the immunoassay system. As a result, the reduction peak of TMB(Ox was measured by using differential pulse voltammetry (DPV analysis. Based on the results, the electrochemical surface area was increased from 0.396 cm2 to 1.298 cm2 due to the electrode

  17. A sensitive, colorimetric immunosensor based on Cu-MOFs and HRP for detection of dibutyl phthalate in environmental and food samples.

    Science.gov (United States)

    Zhu, Nuanfei; Zou, Yanmin; Huang, Menglu; Dong, Shuaibing; Wu, Xiangyang; Liang, Guoxi; Han, Zhixiang; Zhang, Zhen

    2018-08-15

    A sensitive and artful colorimetric immunosensor based on horseradish peroxidase (HRP) was designed by labelling metal-organic frameworks (Cu-MOFs) on the second antibody (Cu-MOFs@Ab 2 ) as signal amplification for the detection of trace dibutyl phthalate (DBP). In this system, when Cu-MOFs@Ab 2 was captured by antigen- primary antibody (Ab 1 ) complex, tremendous Cu(II) will be released from Cu-MOFs in the presence of nitric acid (HNO 3 ), and Cu(II) will be further reduced to Cu(I) after the addition of sodium ascorbate (SA), consequently, inhibiting the HRP to catalyse the colorless 3,3',5,5'-tetramethylbenzidine (TMB) into blue oxidized TMB (ox TMB). Under the optimized conditions, the limit of detection (LOD) was 1 μg L -1 , which was almost 60 times lower than that using a conventional ELISA with the same antibody. In addition, our method showed good accuracy and reproducibility (recoveries of 87.73-103.4%; CV values of 1.46-5.95%) through a spike-recovery analysis. The proposed immunosensor indicated great potential for trace DBP determination from environmental and food samples. Copyright © 2018. Published by Elsevier B.V.

  18. Development of an Electrochemical Immunosensor for Fumonisins Detection in Foods

    Science.gov (United States)

    Kadir, Mohamad Kamal Abdul; Tothill, Ibtisam E.

    2010-01-01

    An electrochemical affinity sensor for the determination of fumonisins mycotoxins (Fms) using monoclonal antibody modified screen-printed gold electrode with carbon counter and silver-silver chloride pseudo-reference electrode is reported in this work. A direct competitive enzyme-linked immunosorbent assay (ELISA) was initially developed, exhibiting a detection limit of 100 µg·L-1 for fumonisins. This was then transferred to the surface of a bare gold screen-printed electrode (SPGE) and detection was performed by chronoamperometry, monitoring the reaction of 3,3’,5,5’-Tetramethylbenzidine dihydrochloride (TMB) and hydrogen peroxide (H2O2) catalysed by HRP at −100 mV potential vs. onboard Ag-AgCl pseudo-reference electrode. The immunosensor exhibited detection limit of 5 µg·L−1 fumonisins with a dynamic range from 1 µg·L−1–1000 µg·L−1. The sensor also performed well in extracted corn samples. PMID:22069591

  19. Detection of γ-irradiation of foods. Use of H2O2-stimulated and photostimulated chemiluminescence. Pt. 1

    International Nuclear Information System (INIS)

    Lewin, G.; Popov, I.N.; Schreiber, G.A.; Helle, N.

    1993-01-01

    Beside methods for unequivocal identification of irradiation treatment of food screening methods which do not always give a final answer are needed for an effective control. In this paper preliminary results are presented which were obtained by measurement of the H 2 O 2 -stimulated and photostimulated chemiluminescence of apples treated by ionising radiation. Appels were chosen as a model for fresh fruit and vegetables. It seems that the H 2 O 2 -stimulated chemiluminescence can be used to screen fruit and vegetables to detect irradiation treatment. (orig.) [de

  20. Preparation of Fe(3)O(4)@C@CNC multifunctional magnetic core/shell nanoparticles and their application in a signal-type flow-injection photoluminescence immunosensor.

    Science.gov (United States)

    Chu, Chengchao; Li, Meng; Li, Long; Ge, Shenguang; Ge, Lei; Yu, Jinghua; Yan, Mei; Song, Xianrang

    2013-11-01

    We describe here the preparation of carbon-coated Fe3O4 magnetic nanoparticles that were further fabricated into multifunctional core/shell nanoparticles (Fe3O4@C@CNCs) through a layer-by-layer self-assembly process of carbon nanocrystals (CNCs). The nanoparticles were applied in a photoluminescence (PL) immunosensor to detect the carcinoembryonic antigen (CEA), and CEA primary antibody was immobilized onto the surface of the nanoparticles. In addition, CEA secondary antibody and glucose oxidase were covalently bonded to silica nanoparticles. After stepwise immunoreactions, the immunoreagent was injected into the PL cell using a flow-injection PL system. When glucose was injected, hydrogen peroxide was obtained because of glucose oxidase catalysis and quenched the PL of the Fe3O4@C@CNC nanoparticles. The here proposed PL immunosensor allowed us to determine CEA concentrations in the 0.005–50 ng·mL-1 concentration range, with a detection limit of 1.8 pg·mL-1.

  1. Facile synthesis of cuprous oxide nanowires decorated graphene oxide nanosheets nanocomposites and its application in label-free electrochemical immunosensor.

    Science.gov (United States)

    Wang, Huan; Zhang, Yong; Wang, Yulan; Ma, Hongmin; Du, Bin; Wei, Qin

    2017-01-15

    In this work, the assembly between one-dimensional (1D) nanomaterials and two-dimensional (2D) nanomaterials was achieved by a simple method. Cuprous oxide nanowires decorated graphene oxide nanosheets (Cu 2 O@GO) nanocomposites were synthesized for the first time by a simple electrostatic self-assembly process. The nanostructure was well confirmed by scanning electron microscope (SEM) and transmission electron microscope (TEM) images. Taking advantages of good electrocatalytic activity and high specific surface area of Cu 2 O@GO nanocomposites, a label-free electrochemical immunosensor was developed by employing Cu 2 O@GO as signal amplification platform for the quantitative detection of alpha fetoprotein (AFP). In addition, toluidine blue (TB) was used as the electron transfer mediator to provide the electrochemical signal, which was adsorbed on graphene oxide nanosheets (GO NSs) by electrostatic attraction. The detection mechanism was based on the monitoring of the electrochemical current response change of TB by the square wave voltammetry (SWV) when immunoreaction occurred on the surface of electrode. Under optimal conditions, the proposed immunosensor displayed a high sensitivity and a low detection limit. This designed method may provide an effective method in the clinical diagnosis of AFP and other tumor markers. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Insights into the ninhydrin chemiluminescent reaction and its potential for micromolar determination of human serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, M. Rodriguez [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Av. Julian Claveria, 8 33006 Oviedo (Spain); Laino, R. Badia [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Av. Julian Claveria, 8 33006 Oviedo (Spain); Diaz-Garcia, M.E. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Av. Julian Claveria, 8 33006 Oviedo (Spain)]. E-mail: medg@uniovi.es

    2006-06-15

    The N-terminal region of human serum albumin (HSA) has an inherent affinity for Co(II) ions. On this basis a new continuous flow method for detection of HSA has been developed taking advantage of the strong quenching effect of the albumin in the ninhydrin-H{sub 2}O{sub 2}-Co(II) chemiluminescent system. The analytical potential of the system is compared with other conventional chemiluminescent reagents. The method gives linear responses from the detection limit (0.30 {mu}M HSA) up to 6.8 {mu}M. The repeatability of the method is good (RSD=7%), it is cheap and rapid to apply and does not require the use of insoluble or expensive reagents nor sophisticated equipment.

  3. Analyzer for measurement of nitrogen oxide concentration by ozone content reduction in gas using solid state chemiluminescent sensor

    Science.gov (United States)

    Chelibanov, V. P.; Ishanin, G. G.; Isaev, L. N.

    2014-05-01

    Role of nitrogen oxide in ambient air is described and analyzed. New method of nitrogen oxide concentration measurement in gas phase is suggested based on ozone concentration measurement with titration by nitrogen oxide. Research of chemiluminescent sensor composition is carried out on experimental stand. The sensor produced on the base of solid state non-activated chemiluminescent composition is applied as ozone sensor. Composition is put on the surface of polymer matrix with developed surface. Sensor compositions includes gallic acid with addition of rodamine-6G. Model of interaction process between sensor composition and ozone has been developed, main products appeared during reaction are identified. The product determining the speed of luminescense appearance is found. This product belongs to quinone class. Then new structure of chemiluminescent composition was suggested, with absence of activation period and with high stability of operation. Experimental model of gas analyzer was constructed and operation algorithm was developed. It was demonstrated that developed NO measuring instrument would be applied for monitoring purposes of ambient air. This work was partially financially supported by Government of Russian Federation, Grant 074-U01

  4. A novel lable-free electrochemical immunosensor for carcinoembryonic antigen based on gold nanoparticles-thionine-reduced graphene oxide nanocomposite film modified glassy carbon electrode.

    Science.gov (United States)

    Kong, Fen-Ying; Xu, Mao-Tian; Xu, Jing-Juan; Chen, Hong-Yuan

    2011-10-15

    In this paper, gold nanoparticle-thionine-reduced graphene oxide (GNP-THi-GR) nanocomposites were prepared to design a label-free immunosensor for the sensitive detection of carcinoembryonic antigen (CEA). The nanocomposites with good biocompatibility, excellent redox electrochemical activity and large surface area were coated onto the glassy carbon electrode (GCE) surface and then CEA antibody (anti-CEA) was immobilized on the electrode to construct the immunosensor. The morphologies and electrochemistry of the formed nanocomposites were investigated by using scanning electron microscopy (SEM), ultraviolet-visible (UV-vis) spectrometry, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). CV and differential pulse voltammetry (DPV) studies demonstrated that the formation of antibody-antigen complexes decreased the peak current of THi in the GNP-THi-GR nanocomposites. The decreased currents were proportional to the CEA concentration in the range of 10-500 pg/mL with a detection limit of 4 pg/mL. The proposed method was simple, fast and inexpensive for the determination of CEA at very low levels. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. The sandwich-type electrochemiluminescence immunosensor for α-fetoprotein based on enrichment by Fe3O4-Au magnetic nano probes and signal amplification by CdS-Au composite nanoparticles labeled anti-AFP.

    Science.gov (United States)

    Zhou, Hankun; Gan, Ning; Li, Tianhua; Cao, Yuting; Zeng, Saolin; Zheng, Lei; Guo, Zhiyong

    2012-10-09

    A novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated on a glassy carbon electrode (GCE) for ultra trace levels of α-fetoprotein (AFP) based on sandwich immunoreaction strategy by enrichment using magnetic capture probes and quantum dots coated with Au shell (CdS-Au) as the signal tag. The capture probe was prepared by immobilizing the primary antibody of AFP (Ab1) on the core/shell Fe(3)O(4)-Au nanoparticles, which was first employed to capture AFP antigens to form Fe(3)O(4)-Au/Ab1/AFP complex from the serum after incubation. The product can be separated from the background solution through the magnetic separation. Then the CdS-Au labeled secondary antibody (Ab2) as signal tag (CdS-Au/Ab2) was conjugated successfully with Fe(3)O(4)-Au/Ab1/AFP complex to form a sandwich-type immunocomplex (Fe(3)O(4)-Au/Ab1/AFP/Ab2/CdS-Au), which can be further separated by an external magnetic field and produce ECL signals at a fixed voltage. The signal was proportional to a certain concentration range of AFP for quantification. Thus, an easy-to-use immunosensor with magnetic probes and a quantum dots signal tag was obtained. The immunosensor performed at a level of high sensitivity and a broad concentration range for AFP between 0.0005 and 5.0 ng mL(-1) with a detection limit of 0.2 pg mL(-1). The use of magnetic probes was combined with pre-concentration and separation for trace levels of tumor markers in the serum. Due to the amplification of the signal tag, the immunosensor is highly sensitive, which can offer great promise for rapid, simple, selective and cost-effective detection of effective biomonitoring for clinical application. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. A novel luminol chemiluminescent method catalyzed by silver/gold alloy nanoparticles for determination of anticancer drug flutamide.

    Science.gov (United States)

    Chaichi, Mohammad Javad; Azizi, Seyed Naser; Heidarpour, Maryam

    2013-12-01

    It was found that silver/gold alloy nanoparticles enhance the chemiluminescence (CL) of the luminol-H2O2 system in alkaline solution. The studies of UV-Vis spectra, CL spectra, effects of concentrations luminol, hydrogen peroxide and silver/gold alloy nanoparticles solutions were carried out to explore the CL enhancement mechanism. Flutamide was found to quench the CL signals of the luminol-H2O2 reaction catalyzed by silver/gold alloy nanoparticles, which made it applicable for the determination of flutamide. Under the optimum conditions, the CL intensity is proportional to the concentration of the flutamide in solution over the range 5.0 × 10(-7) to 1.0 × 10(-4)mol L(-1). Detection limit was obtained 1.2 × 10(-8)mol L(-1)and the relative standard deviation (RSD) γ5%. This work is introduced as a new method for the determination of flutamide in commercial tablets. Box-Behnken experimental design is applied to investigate and validate the CL measurement parameters. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Estimation of tritium activity in bioassay samples having chemiluminescence

    International Nuclear Information System (INIS)

    Dwivedi, R.K.; Manu, Kumar; Kumar, Vinay; Soni, Ashish; Kaushik, A.K.; Tiwari, S.K.; Gupta, Ashok

    2008-01-01

    Tritium is recognized as major internal dose contributor in PHWR type of reactors. Estimation of internal dose due to tritium is carried out by analyzing urine samples in liquid scintillation analyzer (LSA). Presence of residual biochemical species in urine samples of some individuals under medical administration shows significant amount of chemiluminescence. If appropriate care is not taken the results obtained by liquid scintillation counter may be mistaken as genuine uptake of tritium. The distillation method described in this paper is used at RAPS-3 and 4 to assess correct tritium uptake. (author)

  8. Multianalyte detection using a capillary-based flow immunosensor.

    Science.gov (United States)

    Narang, U; Gauger, P R; Kusterbeck, A W; Ligler, F S

    1998-01-01

    A highly sensitive, dual-analyte detection system using capillary-based immunosensors has been designed for explosive detection. This model system consists of two capillaries, one coated with antibodies specific for 2,4,6-trinitrotoluene (TNT) and the other specific for hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) combined into a single device. The fused silica capillaries are prepared by coating anti-TNT and anti-RDX antibodies onto the silanized inner walls using a hetero-bifunctional crosslinker. After immobilization, the antibodies are saturated with a suitable fluorophorelabeled antigen. A "T" connector is used to continuously flow the buffer solution through the individual capillaries. To perform the assay, an aliquot of TNT or RDX or a mixture of the two analytes is injected into the continuous flow stream. In each capillary, the target analyte displaces the fluorophore-labeled antigen from the binding pocket of the antibody. The labeled antigen displaced from either capillary is detected downstream using two portable spectrofluorometers. The limits of detection for TNT and RDX in the multi-analyte formate are 44 fmol (100 microliters of 0.1 ng/ml TNT solution) and 224 fmol (100 microliters of 0.5 ng/ml RDX solution), respectively. The entire assay for both analytes can be performed in less than 3 min.

  9. Enhanced immunoassay for porcine circovirus type 2 antibody using enzyme-loaded and quantum dots-embedded shell–core silica nanospheres based on enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Wu, Long; Li, Xuepu; Shao, Kang; Ye, Shiyi; Liu, Chen; Zhang, Chenjun; Han, Heyou

    2015-01-01

    Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL −1 with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics. - Highlights: • A versatile ELISA-based immunoassay for PCV2 antibody was developed. • Enzyme and CdSe QDs modified SiO 2 particles were used to improve sensitivity. • The simultaneous three ELISA-based techniques enhanced the detection reliability. • The biosensors strategy could provide a new avenue to ELISA-based sensors

  10. Enhanced immunoassay for porcine circovirus type 2 antibody using enzyme-loaded and quantum dots-embedded shell–core silica nanospheres based on enzyme-linked immunosorbent assay

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Long; Li, Xuepu; Shao, Kang; Ye, Shiyi; Liu, Chen; Zhang, Chenjun; Han, Heyou, E-mail: hyhan@mail.hzau.edu.cn

    2015-08-05

    Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL{sup −1} with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics. - Highlights: • A versatile ELISA-based immunoassay for PCV2 antibody was developed. • Enzyme and CdSe QDs modified SiO{sub 2} particles were used to improve sensitivity. • The simultaneous three ELISA-based techniques enhanced the detection reliability. • The biosensors strategy could provide a new avenue to ELISA-based sensors.

  11. Flow Injection Photosensitized Chemiluminescence of Luminol with Cu(II-Rose Bengal: Mechanistic Approach and Vitamin A and C Determination

    Directory of Open Access Journals (Sweden)

    Muhammad Asgher

    2014-01-01

    Full Text Available Rose Bengal photosensitized flow injection chemiluminescence method is reported using luminol-Cu(II for the determination of vitamins A and C in pharmaceutical formulations. The reaction is based on the enhancement effect of analyte in the production of anion radicals of Rose Bengal (RB•− which rapidly interact with dissolved oxygen and generate superoxide anions radicals (O2•− and hydrogen peroxide (H2O2. Highly reactive hydroxyl radicals (•OH were produced via dismutation of H2O2 by catalyst (Cu2+. The generated superoxide anions radicals and hydroxyl radicals thus oxidize luminol in alkaline medium to generate strong chemiluminescence. The limit of detection (3s of the blank, n=6 of vitamins A and C and RB was found to be 0.008, 0.005, and 0.05 μg mL−1, respectively. The sample throughput of 70 h−1 for vitamins A and C and 30 h−1 for RB was found. Calibration curve was linear in the range of 0.05–15, 0.01–20, and 0.1–50 μg mL−1 for vitamins A and C and RB, respectively, with relative standard deviations (RSDs; n=3 in the range 1.6–3.6%. The method was successfully applied to pharmaceutical formulations and the results obtained were in good agreement with the labeled values.

  12. An ultrasensitive sandwich-type electrochemical immunosensor based on the signal amplification system of double-deck gold film and thionine unite with platinum nanowire inlaid globular SBA-15 microsphere.

    Science.gov (United States)

    Wang, Ping; Li, Mingdang; Pei, Fubin; Li, Yueyun; Liu, Qing; Dong, Yunhui; Chu, Qingyan; Zhu, Hongjun

    2017-05-15

    A novel thionine unites with platinum nanowire inlaid globular SBA-15 (Pt NWs@g-SBA-15/Thi) not only utilizes as an efficient electrical signal probe but also constitutes an amplifying system with double-deck gold film (D-Au film) have been applied to the fabrication of sandwich-type immunosensor for detecting hepatitis B surface antigen (HBs Ag). The D-Au film can accelerate the electron transfer on the electrode interface due to the tunneling effect between the two Au films and can improve the load capacity of primary antibodies (Ab 1 ) because of the good biocompatibility. The Pt NWs@g-SBA-15/Thi with uniform globular morphology not only can effectively reduce the spatial limitation for loading the secondary antibodies (Ab 2 ) but also can provide outstanding pore accessibility of guest species from outside and offer catalytically active sites in a large scale. Besides, the presence of Thi can well enhance the electrical conductivity of Pt NWs@g-SBA-15/Thi. With the good cooperation between D-Au film and Pt NWs@g-SBA-15/Thi, a linear relationship between current signals and the concentrations of HBs Ag was obtained in the wide range from 10 fg/mL to 100ng/mL and the detection limit of HBs Ag was 3.3 fg/mL (signal-to-noise ratio of 3). Furthermore, the designed immunosensor with excellent selectivity, reproducibility and stability shows excellent performance in detection of human serum samples and provides a promising capacity for detecting a wide range of other tumor markers in clinical application. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Flame Structure and Chemiluminescence Emissions of Inverse Diffusion Flames under Sinusoidally Driven Plasma Discharges

    Directory of Open Access Journals (Sweden)

    Maria Grazia De Giorgi

    2017-03-01

    Full Text Available Reduction of nitric oxides (NOx in aircraft engines and in gas turbines by lean combustion is of great interest in the design of novel combustion systems. However, the stabilization of the flame under lean conditions is a main issue. In this context, the present work investigates the effects of sinusoidal dielectric barrier discharge (DBD on a lean inverse diffusive methane/air flame in a Bunsen-type burner under different actuation conditions. The flame appearance was investigated with fixed methane loading (mass flux, but with varying inner airflow rate. High-speed flame imaging was done by using an intensified (charge-coupled device CCD camera equipped with different optical filters in order to selectively record signals from the chemiluminescent species OH*, CH*, or CO2* to evaluate the flame behavior in presence of plasma actuation. The electrical power consumption was less than 33 W. It was evident that the plasma flame enhancement was significantly influenced by the plasma discharges, particularly at high inner airflow rates. The flame structure changes drastically when the dissipated plasma power increases. The flame area decreases due to the enhancement of mixing and chemical reactions that lead to a more anchored flame on the quartz exit with a reduction of the flame length.

  14. Visual and efficient immunosensor technique for advancing biomedical applications of quantum dots on Salmonella detection and isolation

    Science.gov (United States)

    Tang, Feng; Pang, Dai-Wen; Chen, Zhi; Shao, Jian-Bo; Xiong, Ling-Hong; Xiang, Yan-Ping; Xiong, Yan; Wu, Kai; Ai, Hong-Wu; Zhang, Hui; Zheng, Xiao-Li; Lv, Jing-Rui; Liu, Wei-Yong; Hu, Hong-Bing; Mei, Hong; Zhang, Zhen; Sun, Hong; Xiang, Yun; Sun, Zi-Yong

    2016-02-01

    It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here by applying fluorescent nanobioprobes on a specially-designed cellulose-based swab (a solid-phase enrichment system). The selective and chromogenic medium used on this swab can achieve the ultrasensitive amplification of target bacteria and form chromogenic colonies in situ based on a simple biochemical reaction. More importantly, because this swab can serve as an attachment site for the targeted pathogens to immobilize and immunologically capture nanobioprobes, our mAb-conjugated QD bioprobes were successfully applied on the solid-phase enrichment system to capture the fluorescence of targeted colonies under a designed excitation light instrument based on blue light-emitting diodes combined with stereomicroscopy or laser scanning confocal microscopy. Compared with the traditional methods using 4-7 days to isolate Salmonella from the bacterial mixture, this method took only 2 days to do this, and the process of initial screening and preliminary diagnosis can be completed in only one and a half days. Furthermore, the limit of detection can reach as low as 101 cells per mL Salmonella on the background of 105 cells per mL non-Salmonella (Escherichia coli, Proteus mirabilis or Citrobacter freundii, respectively) in experimental samples, and even in human anal ones. The visual and efficient immunosensor technique may be proved to be a favorable alternative for screening and isolating Salmonella in a large number of samples related to public health surveillance.It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here

  15. Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Yang Zhanjun [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); College of Chemistry and Engineering, Yangzhou University, 88 South University Avenue, Yangzhou 225002 (China); Zong Chen [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Ju Huangxian, E-mail: hxju@nju.edu.cn [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Yan Feng, E-mail: yanfeng2007@sohu.com [Jiangsu Institute of Cancer Prevention and Cure, Nanjing 210009 (China)

    2011-11-07

    Highlights: {yields} A novel capillary immune microreactor was proposed for highly efficient flow-through chemiluminescent immunoassay. {yields} The microreactor was prepared by functionalizing capillary inner wall with streptavidin for capture of biotinylated antibody. {yields} The proposed immunoassay method showed wide dynamic range, good reproducibility, stability and practicality. {yields} The microreactor was low-cost and disposable, and possessed several advantages over the conventional immunoreactors. - Abstract: A streptavidin functionalized capillary immune microreactor was designed for highly efficient flow-through chemiluminescent (CL) immunoassay. The functionalized capillary could be used as both a support for highly efficient immobilization of antibody and a flow cell for flow-through immunoassay. The functionalized inner wall and the capture process were characterized using scanning electron microscopy. Compared to conventional packed tube or thin-layer cell immunoreactor, the proposed microreactor showed remarkable properties such as lower cost, simpler fabrication, better practicality and wider dynamic range for fast CL immunoassay with good reproducibility and stability. Using {alpha}-fetoprotein as model analyte, the highly efficient CL flow-through immunoassay system showed a linear range of 3 orders of magnitude from 0.5 to 200 ng mL{sup -1} and a low detection limit of 0.1 ng mL{sup -1}. The capillary immune microreactor could make up the shortcoming of conventional CL immunoreactors and provided a promising alternative for highly efficient flow-injection immunoassay.

  16. Development of luminol-N-hydroxyphthalimide chemiluminescence system for highly selective and sensitive detection of superoxide dismutase, uric acid and Co2.

    Science.gov (United States)

    Saqib, Muhammad; Qi, Liming; Hui, Pan; Nsabimana, Anaclet; Halawa, Mohamed Ibrahim; Zhang, Wei; Xu, Guobao

    2018-01-15

    N-hydroxyphthalimide (NHPI), a well known reagent in organic synthesis and biochemical applications, has been developed as a stable and efficient chemiluminescence coreactant for the first time. It reacts with luminol much faster than N-hydroxysuccinimide, eliminating the need of a prereaction coil used in N-hydroxysuccinimide system. Without using prereaction coil, the chemiluminescence peak intensities of luminol-NHPI system are about 102 and 26 times greater than that of luminol-N-hydroxysuccinimide system and classical luminol-hydrogen peroxide system, respectively. The luminol-NHPI system achieves the highly sensitive detection of luminol (LOD = 70pM) and NHPI (LOD = 910nM). Based on their excellent quenching efficiencies, superoxide dismutase and uric acid are sensitively detected with LODs of 3ng/mL and 10pM, respectively. Co 2+ is also detected a LOD of 30pM by its remarkable enhancing effect. Noteworthily, our method is at least 4 orders of magnitude more sensitive than previously reported uric acid detection methods, and can detect uric acid in human urine and Co 2+ in tap and lake water real samples with excellent recoveries in the range of 96.35-102.70%. This luminol-NHPI system can be an important candidate for biochemical, clinical and environmental analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Irradiation monitoring of spices by chemiluminescence method

    International Nuclear Information System (INIS)

    Bhatti, K.A.; Khan, H.M.; Sattar, A.; Ahmad, A.

    2001-01-01

    Some spices (cumin, coriander, black pepper and red pepper), commonly used due to their specific aroma and nutritional value were studied using chemiluminescence (CL) method to test whether the food has been irradiated or not. The spices were ground to different mesh sizes and subjected to gamma ray doses of 2.5, 5.0, 7.5 and 10 Kgy. The effect of radiation doses and particle size on the CL response of irradiated and un-irradiated samples was checked using luminol and lucigenin sensitizers. The storage experiment was also performed for all spices with both the sensitizers in order to pick the suitable sensitizer for CL study. During this study Co-60 gamma ray source and Bio-orbit 1250 luminometer were used after precise calibration

  18. An innovative immunosensor for ultrasensitive detection of breast cancer specific carbohydrate (CA 15-3) in unprocessed human plasma and MCF-7 breast cancer cell lysates using gold nanospear electrochemically assembled onto thiolated graphene quantum dots.

    Science.gov (United States)

    Hasanzadeh, Mohammad; Tagi, Solmaz; Solhi, Elham; Mokhtarzadeh, Ahad; Shadjou, Nasrin; Eftekhari, Aziz; Mahboob, Soltanali

    2018-04-03

    The accurate quantification of the level of breast cancer specific protein CA 15-3 in serum is crucial for cancer prognosis. This work, a novel and sensitive label-free immunoassay based on gold nanospear (Au NSs) electrochemically assembled onto thiolated graphene quantum dots (CysA/GQDs) for the detection of CA 15-3 antibodies. The CysA/Au NSs/GQDs hybrid interface provides a large surface area for the effective immobilization of CA 15-3 antigens, as well as it ascertains the bioactivity and stability of immobilized CA 15-3 antigens. Field emission scanning electron microscope (FE-SEM), and EDS photoelectron spectroscopies were used to monitor the sensor fabrication. Also, cyclic voltammetry was used to quantify the extent of Au NSs' surface coverage by CA 15-3 antigens. Square wave voltammetry (SWV) was employed to investigate the immunosensor fabrication and to monitor the binding events between CA 15-3 antigens-antibodies. Under optimized experimental conditions, the immunosensor displayed good sensitivity and specificity. The CA 15-3 were detected in a concentration as low as 0.11U/mL with a linear range from 0.16-125U/mL. The high sensitivity of the immunosensor may derive from the high loading of CA 15-3 antibodies on CysA/Au NSs/GQDs hybrid interface which increases the number of binding events. The method was successfully applied assay of the CA 15-3 in unprocessed human plasma samples. Also, proposed immunosensor was applied to the assay of CA 15-3 malignant cell line lysates (human breast adenocarcinoma cell line-MCF-7). Copyright © 2018. Published by Elsevier B.V.

  19. An ultrasensitive electrochemiluminescent immunosensor based on graphene oxide coupled graphite-like carbon nitride and multiwalled carbon nanotubes-gold for the detection of diclofenac.

    Science.gov (United States)

    Hu, Liuyi; Zheng, Jing; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-03-15

    In this study, a novel competition-type electrochemiluminescent (ECL) immunosensor for detecting diclofenac (DCF) was fabricated with graphene oxide coupled graphite-like carbon nitride (GO-g-C 3 N 4 ) as signal probe for the first time. The ECL intensity of carboxylated g-C 3 N 4 was significantly enhanced after being combined with graphene oxide (GO) which exhibited excellent charge-transport property. The sensing platform was constructed by multiwalled carbon nanotubes and gold nanoparticles (MWCNTs-AuNPs), which not only provided an effective matrix for immobilizing a large amount of coating antigen but also facilitated the electronic transmission rate to enhance the ECL intensity. Based on the synergistic effect of GO-g-C 3 N 4 and MWCNTs-AuNPs composite, the proposed sensor showed high sensitivity, good stability, and wide linearity for the detection of DCF in the range of 0.005-1000ngmL -1 with a detection limit of 1.7pgmL -1 . Furthermore, the developed immunoassay has been applied to real samples with satisfactory results. Therefore, this work provided a promising method for the detection of DCF and other small molecular compounds in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Microspot-based ELISA in microfluidics: chemiluminescence and colorimetry detection using integrated thin-film hydrogenated amorphous silicon photodiodes.

    Science.gov (United States)

    Novo, Pedro; Prazeres, Duarte Miguel França; Chu, Virginia; Conde, João Pedro

    2011-12-07

    Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.

  1. Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index.

    Science.gov (United States)

    Nalewajko-Sieliwoniuk, Edyta; Iwanowicz, Magdalena; Kalinowski, Sławomir; Kojło, Anatol

    2016-03-10

    In this work, we present a novel chemiluminescence (CL) method based on direct-injection detector (DID) integrated with the multi-pumping flow system (MPFS) to chemiluminescence determination of the total polyphenol index. In this flow system, the sample and the reagents are injected directly into the cone-shaped detection cell placed in front of the photomultiplier window. Such construction of the detection chamber allows for fast measurement of the CL signal in stopped-flow conditions immediately after mixing the reagents. The proposed DID-CL-MPFS method is based on the chemiluminescence of nanocolloidal manganese(IV)-hexametaphosphate-ethanol system. The application of ethanol as a sensitizer, eliminated the use of carcinogenic formaldehyde. Under the optimized experimental conditions, the chemiluminescence intensities are proportional to the concentration of gallic acid in the range from 5 to 350 ng mL(-1). The DID-CL-MPFS method offers a number of advantages, including low limit of detection (0.80 ng mL(-1)), high precision (RSD = 3.3%) and high sample throughput (144 samples h(-1)) as well as low consumption of reagents, energy and low waste generation. The proposed method has been successfully applied to determine the total polyphenol index (expressed as gallic acid equivalent) in a variety of plant-derived food samples (wine, tea, coffee, fruit and vegetable juices, herbs, spices). Copyright © 2016 Elsevier B.V. All rights reserved.

  2. An Elegant Analysis of White Spot Syndrome Virus Using a Graphene Oxide/Methylene Blue based Electrochemical Immunosensor Platform

    Science.gov (United States)

    Natarajan, Anusha; Devi, K. S. Shalini; Raja, Sudhakaran; Senthil Kumar, Annamalai

    2017-04-01

    White spot syndrome virus (WSSV) is a major devastating virus in aquaculture industry. A sensitive and selective diagnostic method for WSSV is a pressing need for the early detection and protection of the aquaculture farms. Herein, we first report, a simple electrochemical immunosensor based on methylene blue dye (MB) immobilized graphene oxide modified glassy carbon electrode (GCE/GO@MB) for selective, quick (35 ± 5 mins) and raw sample analysis of WSSV. The immunosensor was prepared by sequential modification of primary antibody, blocking agent (bovine serum album), antigen (as vp28 protein), secondary antibody coupled with horseradish peroxidase (Ab2-HRP) on the GCE/GO@MB. The modified electrode showed a well-defined redox peak at an equilibrium potential (E1/2), -0.4 V vs Ag/AgCl and mediated H2O2 reduction reaction without any false positive result and dissolved oxygen interferences in pH 7 phosphate buffer solution. Under an optimal condition, constructed calibration plot was linear in a range of 1.36 × 10-3 to 1.36 × 107 copies μL-1 of vp28. It is about four orders higher sensitive than that of the values observed with polymerase chain reaction (PCR) and western blot based WSSV detection techniques. Direct electrochemical immunosensing of WSSV in raw tissue samples were successfully demonstrated as a real sample system.

  3. Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

    Science.gov (United States)

    Dunham, A. J.; Barkley, R. M.; Sievers, R. E.; Clarkson, T. W. (Principal Investigator)

    1995-01-01

    An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

  4. l-Tyrosine Contained in Dietary Supplement by Chemiluminescence Reaction of an Iron-Phthalocyanine Complex

    Directory of Open Access Journals (Sweden)

    Takao Ohtomo

    2012-01-01

    Full Text Available The chemiluminescence (CL signal immediately appeared when a hydrogen peroxide solution was injected into an iron-phthalocyanine tetrasulfonic acid (Fe-PTS aqueous solution. Moreover, the CL intensity of Fe-PTS decreased by adding L-tyrosine. Based on these results, the determination of trace amounts of L-tyrosine was developed using the quenching-chemiluminescence. The calibration curve of L-tyrosine was obtained in the concentration range of 2.0×10−7 M to 2.0×10−5 M. Moreover, the relative standard deviation (RSD was 1.63 % (=5 for 2.0×10−6 M L-tyrosine, and its detection limits (3σ were 1.81×10−7 M. The spike and recovery experiments for L-tyrosine were performed using a soft drink. Furthermore, the determination of L-tyrosine was applied to supplements containing various kinds of amino acids. Each satisfactory relative recovery was obtained at 98 to 102%.

  5. Selective Detection of Neurotransmitters by Fluorescence and Chemiluminescence Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ziqiang Wang; Edward S. Yeung

    2001-08-06

    In recent years, luminescence imaging has been widely employed in neurochemical analysis. It has a number of advantages for the study of neuronal and other biological cells: (1) a particular molecular species or cellular constituent can be selectively visualized in the presence of a large excess of other species in a heterogeneous environment; (2) low concentration detection limits can be achieved because of the inherent sensitivity associated with fluorescence and chemiluminescence; (3) low excitation intensities can be used so that long-term observation can be realized while the viability of the specimen is preserved; and (4) excellent spatial resolution can be obtained with the light microscope so subcellular compartments can be identified. With good sensitivity, temporal and spatial resolution, the flux of ions and molecules and the distribution and dynamics of intracellular species can be measured in real time with specific luminescence probes, substrates, or with native fluorescence. A noninvasive detection scheme based on glutamate dehydrogenase (GDH) enzymatic assay combined with microscopy was developed to measure the glutamate release in cultured cells from the central nervous system (CNS). The enzyme reaction is very specific and sensitive. The detection limit with CCD imaging is down to {micro}M levels of glutamate with reasonable response time. They also found that chemiluminescence associated with the ATP-dependent reaction between luciferase and luciferin can be used to image ATP at levels down to 10 nM in the millisecond time scale. Similar imaging experiments should be feasible in a broad spectrum of biological systems.

  6. The synthesis and chemiluminescence of a stable 1,2-dioxetane : an organic chemistry laboratory experiment

    NARCIS (Netherlands)

    Meijer, E.W.; Wynberg, H.

    1982-01-01

    An expt. for the synthesis of adamantylideneadamantane-1,2-dioxetane illustrating the concepts of the singlet O reaction and chemiluminescence, is described. All intermediates and products can be identified by undergraduate students using routine spectroscopic anal. [on SciFinder (R)

  7. Luminol-dependent chemiluminescence in antibody-sensitized neutrophils stimulated with protein A-bearing staphylococci.

    Science.gov (United States)

    Nishihara, S; Seki, K; Ikigai, H; Masuda, S

    1988-01-01

    When mouse polymorphonuclear leukocytes (PMNs) sensitized with rabbit antibody to mouse Ehrlich ascites tumor cells were stimulated by Staphylococcus aureus Cowan I cells, a conspicuous luminol-dependent chemiluminescence was observed in the absence of opsonin. The profile of the chemiluminescence (CL) response evoked by staphylococcal cells from antibody-sensitized PMNs had two peaks. An initial peak, observed within 1 min after stimulation, was sharp and high and a second peak, observed about 5 min after stimulation, was low and extended. The CL response of antibody-sensitized PMNs stimulated by S. aureus Cowan I cells was dose-dependently blocked by preincubation with soluble SpA. Cells of a mutant derived from S. aureus Cowan I strain with trace amounts of cell-bound SpA failed to stimulate the antibody-sensitized PMNs to generate the CL response. The antibody-sensitized PMNs were found to phagocytize SpA-bearing S. aureus cells even in the absence of opsonic serum. These results suggest that the observation presented here might provide a useful tool for the investigation of CL response of PMNs.

  8. Permanganate-bromide-silver nanoparticles as a new chemiluminescence system and its application to captopril determination.

    Science.gov (United States)

    Amjadi, Mohammad; Manzoori, Jamshid L; Hassanzadeh, Javad; Sorouraddin, Mohammad H

    2013-10-15

    A novel chemiluminescence (CL) system based on the oxidation of bromide by permanganate in sulfuric acid medium is introduced. The enhancing effect of silver nanoparticles (NPs), synthesized by chemical reduction method, on this reaction was studied. It was demonstrated that spherical silver nanoparticles with average size of 18 nm had a most remarkable catalytic effect on this reaction. CL emission wavelengths and UV-vis spectra were used to characterize the system and propose a possible mechanism. Furthermore, it was found that captopril inhibits the action of NPs and decreases the intensity of CL. Based on this phenomenon, a new CL method was developed for the determination of captopril in the 3.0 × 10(-10) to 1.0 × 10(-7) mol L(-1) concentration range with a detection limit (3s) of 0.12 nmol L(-1). The method was successfully applied to the determination of captopril in pharmaceutical formulations, human urine and serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. A sensitive chemiluminescent immunoassay to detect Chromotrope FB (Chr FB) in foods.

    Science.gov (United States)

    Xu, Kun; Long, Hao; Xing, Rongge; Yin, Yongmei; Eremin, Sergei A; Meng, Meng; Xi, Rimo

    2017-03-01

    Chromotrope FB (Chr FB) is a synthetic azo dye permitted for use in foods and medicines. An acceptable daily intake (ADI) of Chr FB was 0-0.5mg/kg in China. In this study, we synthesized a Chr FB hapten with an amino group to prepare its artificial immunogen. Polyclonal antibodies obtained from New Zealand rabbits were applied to develop an indirect competitive chemiluminescent immunoassay (icCLIA) to detect Chr FB in foods. A horseradish peroxidase (HRP)-luminol-H 2 O 2 system was used to yield CL signal with p-iodophenol as an enhancement reagent. The method showed good specificity towards Chr FB and could detect as low as 0.02ngmL -1 Chr FB in buffer, 0.07ngg -1 in yoghurt candy, 0.07ngg -1 in vitamin drink and 0.13ngg -1 in bread. Compared with HPLC method, the proposed method is more sensitive by two orders of magnitude. The accuracy and precision of this method are acceptable and comparable with HPLC method. Therefore, the proposed method could be used for rapid screening of Chr FB in the mentioned foodstuffs. Copyright © 2016. Published by Elsevier B.V.

  10. Inhibition of chemiluminescence by carvedilol in the cell-free system, whole human blood and blood cells

    Czech Academy of Sciences Publication Activity Database

    Nosál, R.; Jančinová, V.; Číž, Milan; Drábiková, K.; Lojek, Antonín; Fábryová, V.

    2005-01-01

    Roč. 65, č. 1 (2005), s. 55-64 ISSN 0036-5513 Institutional research plan: CEZ:AV0Z50040507 Keywords : blood platelets * carvedilol * chemiluminescence Subject RIV: BO - Biophysics Impact factor: 0.946, year: 2005

  11. Quinone-Based Polymers for Label-Free and Reagentless Electrochemical Immunosensors: Application to Proteins, Antibodies and Pesticides Detection

    Directory of Open Access Journals (Sweden)

    Minh-Chau Pham

    2013-01-01

    Full Text Available Polyquinone derivatives are widely recognized in the literature for their remarkable properties, their biocompatibility, simple synthesis, and easy bio-functionalization. We have shown that polyquinones present very stable electroactivity in neutral aqueous medium within the cathodic potential domain avoiding side oxidation of interfering species. Besides, they can act as immobilized redox transducers for probing biomolecular interactions in sensors. Our group has been working on devices based on such modified electrodes with a view to applications for proteins, antibodies and organic pollutants using a reagentless label-free electrochemical immunosensor format. Herein, these developments are briefly reviewed and put into perspective.

  12. Flow injection chemiluminescence determination of lercanidipine based on N-chlorosuccinimide-eosin Y post-chemiluminescence reaction.

    Science.gov (United States)

    Wang, Guowei; Zhao, Fang; Gao, Ying

    2014-12-01

    A novel post-chemiluminescence (PCL) reaction was discovered when lercanidipine was injected into the CL reaction mixture of N-chlorosuccinimide with alkaline eosin Y in the presence of cetyltrimethylammonium bromide (CTAB), where eosin Y was used as the CL reagent and CTAB as the surfactant. Based on this observation, a simple and highly sensitive PCL method combined with a flow injection (FI) technique was developed for the assay of lercanidipine. Under optimum conditions, the CL signal was linearly related to the concentration of lercanidipine in the range 7.0 × 10(-10) to 3.0 × 10(-6)  g/mL with a detection limit of 2.3 × 10(-10) g/mL (3σ). The relative standard deviation (RSD) was 2.1% for 1.0 × 10(-8) g/mL lercanidipine (n = 13). The proposed method had been applied to the estimation of lercanidipine in tablets and human serum samples with satisfactory results. The possible CL mechanism is also discussed briefly. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Determination of vitamin C in drugs using of an optimized novel TCPO–Amplex red–gold/silver alloy nanoparticles–H2O2 chemiluminescence method by the Box–Behnken design

    International Nuclear Information System (INIS)

    Chaichi, M.J.; Alijanpour, S.O.

    2013-01-01

    Response surface methodology (RSM), based on a Box–Behnken design (BBD) was used to optimize three of the most important operating variables (concentrations of TCPO, Amplex red and pH effect) at peroxyoxalate-chemiluminescence (PO-CL) system. For the first time Amplex red (AR) was introduced as a new fluorescent emitter for predicting the reaction mechanism of PO-CL by means of the fluorescence property of its oxidation product. In optimum conditions, it was found that Au/Ag alloy nanoparticles (NPs) could enhance the CL intensity and the method sensitivity toward the evaluation of trace amount of vitamin C. Based on the antioxidant property of vitamin C noticeably the CL signal of the bis-(2,4,6-trichlorophenyl)oxalate–AR–NPs–hydrogen peroxide–sodium salicylate system was quenched in a low basic medium. A simple, rapid and sensitive CL method for the determination of vitamin C has been developed. The results showed a linear relationship between vitamin C concentration and PO-CL intensity in the range of 0.082–82.7 μg/mL. Detection limit of 0.012 μg/mL and the relative standard deviation (RSD)<4% was obtained. - Highlights: ► The Box-Behnken design was used to optimize peroxyoxalate-chemiluminescence system. ► Amplex red is as new fluorescent emitters for peroxyoxalate chemiluminescence. ► It is introduce a method for determination of vitamin C. ► Detection limit of vitamin C was obtained about 0.012 μg/mL.

  14. Combustion stratification study of partially premixed combustion using Fourier transform analysis of OH* chemiluminescence images

    KAUST Repository

    Izadi Najafabadi, Mohammad

    2017-11-06

    A relatively high level of stratification (qualitatively: lack of homogeneity) is one of the main advantages of partially premixed combustion over the homogeneous charge compression ignition concept. Stratification can smooth the heat release rate and improve the controllability of combustion. In order to compare stratification levels of different partially premixed combustion strategies or other combustion concepts, an objective and meaningful definition of “stratification level” is required. Such a definition is currently lacking; qualitative/quantitative definitions in the literature cannot properly distinguish various levels of stratification. The main purpose of this study is to objectively define combustion stratification (not to be confused with fuel stratification) based on high-speed OH* chemiluminescence imaging, which is assumed to provide spatial information regarding heat release. Stratification essentially being equivalent to spatial structure, we base our definition on two-dimensional Fourier transforms of photographs of OH* chemiluminescence. A light-duty optical diesel engine has been used to perform the OH* bandpass imaging on. Four experimental points are evaluated, with injection timings in the homogeneous regime as well as in the stratified partially premixed combustion regime. Two-dimensional Fourier transforms translate these chemiluminescence images into a range of spatial frequencies. The frequency information is used to define combustion stratification, using a novel normalization procedure. The results indicate that this new definition, based on Fourier analysis of OH* bandpass images, overcomes the drawbacks of previous definitions used in the literature and is a promising method to compare the level of combustion stratification between different experiments.

  15. Label-free genotyping of cytochrome P450 2D6*10 using ligation-mediated strand displacement amplification with DNAzyme-based chemiluminescence detection.

    Science.gov (United States)

    Wang, Hong-Qi; Wu, Zhan; Zhang, Yan; Tang, Li-Juan; Yu, Ru-Qin; Jiang, Jian-Hui

    2012-01-13

    Genotyping of cytochrome P450 monooxygenase 2D6*10 (CYP2D6*10) plays an important role in pharmacogenomics, especially in clinical drug therapy of Asian populations. This work reported a novel label-free technique for genotyping of CYP2D6*10 based on ligation-mediated strand displacement amplification (SDA) with DNAzyme-based chemiluminescence detection. Discrimination of single-base mismatch is firstly accomplished using DNA ligase to generate a ligation product. The ligated product then initiates a SDA reaction to produce aptamer sequences against hemin, which can be probed by chemiluminescence detection. The proposed strategy is used for the assay of CYP2D6*10 target and the genomic DNA. The results reveal that the proposed technique displays chemiluminescence responses in linear correlation to the concentrations of DNA target within the range from 1 pM to 1 nM. A detection limit of 0.1 pM and a signal-to-background ratio of 57 are achieved. Besides such high sensitivity, the proposed CYP2D6*10 genotyping strategy also offers superb selectivity, great robustness, low cost and simplified operations due to its label-free, homogeneous, and chemiluminescence-based detection format. These advantages suggest this technique may hold considerable potential for clinical CYP2D6*10 genotyping and association studies. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. A simple and sensitive immunoassay for the determination of human chorionic gonadotropin by graphene-based chemiluminescence resonance energy transfer.

    Science.gov (United States)

    Lei, Jiuqian; Jing, Tao; Zhou, Tingting; Zhou, Yusun; Wu, Wei; Mei, Surong; Zhou, Yikai

    2014-04-15

    In this study, we report a strategy of chemiluminescence resonance energy transfer (CRET) using graphene as an efficient long-range energy acceptor. Magnetic nanoparticles were also used in CRET for simple magnetic separation and immobilization of horseradish peroxidase (HRP)-labeled anti-HCG antibody. In the design of CRET system, the sandwich-type immunocomplex was formed between human chorionic gonadotropin (HCG, antigen) and two different antibodies bridged the magnetic nanoparticles and graphene (acceptors), which led to the occurrence of CRET from chemiluminescence light source to graphene. After optimizing the experimental conditions, the quenching of chemiluminescence signal depended linearly on the concentration of HCG in the range of 0.1 mIU mL(-1)-10 mIU mL(-1) and the detection limit was 0.06 mIU mL(-1). The proposed method was successfully applied for the determination of HCG levels in saliva and serum samples, and the results were in good agreement with the plate ELISA with colorimetric detection. It could also be developed for detection of other antigen-antibody immune complexes by using the corresponding antigens and respective antibodies. © 2013 Published by Elsevier B.V.

  17. Evaluation and Comparison of Chemiluminescence and UV Photometric Methods for Measuring Ozone Concentrations in Ambient Air

    Science.gov (United States)

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O3) that may be p...

  18. Zinc-doping enhanced cadmium sulfide electrochemiluminescence behavior based on Au-Cu alloy nanocrystals quenching for insulin detection.

    Science.gov (United States)

    Zhu, Wenjuan; Wang, Chao; Li, Xiaojian; Khan, Malik Saddam; Sun, Xu; Ma, Hongmin; Fan, Dawei; Wei, Qin

    2017-11-15

    Novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated for insulin detection. Au-ZnCd 14 S combined nitrogen doping mesoporous carbons (Au-ZnCd 14 S/NH 2 -NMCs) acted as sensing platform and Au-Cu alloy nanocrystals were employed as labels to quench the ECL of Au-ZnCd 14 S/NH 2 -NMCs. Zinc-doping promoted the ECL behavior of CdS nanocrystals, with the best ECL emission obtained when the molar ratio of Zn/Cd was 1:14. Simultaneously, the modification of gold nanoparticles (Au NPs) and combination with NH 2 -NMC further enhanced the ECL emission of ZnCd 14 S due to its excellent conductivity and large specific surface area, which is desirable for the immunosensor construction. Au-Cu alloy nanocrystals were employed in the ECL system of ZnCd 14 S/K 2 S 2 O 8 triggering ECL quenching effects. The ECL spectra of ZnCd 14 S, acting as the energy donor, exhibited well overlaps with the absorption band of Au-Cu alloy nanocrystals which acted as the energy acceptor, leading to an effective ECL resonance energy transfer (ECL-RET). On the basis of the ECL quenching effects, a sensitive ECL immunosensor for insulin detection was successfully constructed with a linear response range of insulin concentration from 0.1pg/mL to 30ng/mL and the limit of detection was calculated to be 0.03pg/mL (S/N = 3). Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results.

    Science.gov (United States)

    Rodrigues, Domingos M C; Lopes, Rafaela N; Franco, Marcos A R; Werneck, Marcelo M; Allil, Regina C S B

    2017-12-19

    Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature by comparing experimental with simulated results. The work studies different shapes of evanescent-wave based fiber optic sensors, adopting a computational modeling to evaluate the probes with the best sensitivity. The simulation showed that for a U-Shaped sensor, the best results can be achieved with a sensor of 980 µm diameter by 5.0 mm in curvature for refractive index sensing, whereas the meander-shaped sensor with 250 μm in diameter with radius of curvature of 1.5 mm, showed better sensitivity for either bacteria and refractive index (RI) sensing. Then, an immunosensor was developed, firstly to measure refractive index and after that, functionalized to detect Escherichia coli . Based on the results with the simulation, we conducted studies with a real sensor for RI measurements and for Escherichia coli detection aiming to establish the best diameter and curvature radius in order to obtain an optimized sensor. On comparing the experimental results with predictions made from the modelling, good agreements were obtained. The simulations performed allowed the evaluation of new geometric configurations of biosensors that can be easily constructed and that promise improved sensitivity.

  20. Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results

    Directory of Open Access Journals (Sweden)

    Domingos M. C. Rodrigues

    2017-12-01

    Full Text Available Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature by comparing experimental with simulated results. The work studies different shapes of evanescent-wave based fiber optic sensors, adopting a computational modeling to evaluate the probes with the best sensitivity. The simulation showed that for a U-Shaped sensor, the best results can be achieved with a sensor of 980 µm diameter by 5.0 mm in curvature for refractive index sensing, whereas the meander-shaped sensor with 250 μm in diameter with radius of curvature of 1.5 mm, showed better sensitivity for either bacteria and refractive index (RI sensing. Then, an immunosensor was developed, firstly to measure refractive index and after that, functionalized to detect Escherichia coli. Based on the results with the simulation, we conducted studies with a real sensor for RI measurements and for Escherichia coli detection aiming to establish the best diameter and curvature radius in order to obtain an optimized sensor. On comparing the experimental results with predictions made from the modelling, good agreements were obtained. The simulations performed allowed the evaluation of new geometric configurations of biosensors that can be easily constructed and that promise improved sensitivity.

  1. Determination of thiram in natural waters using flow-injection with cerium(IV)-quinine chemiluminescence system.

    Science.gov (United States)

    Waseem, Amir; Yaqoob, Mohammad; Nabi, Abdul

    2010-01-01

    A simple and rapid flow-injection chemiluminescence method has been developed for the determination of dithiocarbamate fungicide thiram based on the chemiluminescence reaction of thiram with ceric sulfate and quinine in aqueous sulfuric acid. The present method allowed the determination of thiram in the concentration range of 7.5-2500 ng/mL and the detection limit (signal-to-noise ratio = 3) was 7.5 ng/mL with sample throughput of 120/h. The relative standard deviation was 2.5% for 10 replicate analyses of 500 ng/mL thiram. The effects of foreign species including various anions and cations present in water at environmentally relevant concentrations and some pesticides were also investigated. The proposed method was applied to determine thiram in spiked natural waters using octadecyl bonded phase silica (C(18)) cartridges for solid-phase extraction. The recoveries were in the range 99 +/- 1 to 104 +/- 1%. Copyright (c) 2009 John Wiley & Sons, Ltd.

  2. Flow-injection chemiluminescent determination of estrogen benzoate using the tris(1,10-phenanthroline) ruthenium(II)-permanganate system.

    Science.gov (United States)

    Ma, Yan; Cao, Wei; Qiao, Shuang; Liu, Wenwen; Yang, Jinghe

    2011-01-01

    Chemiluminescence (CL) detection for the determination of estrogen benzoate, using the reaction of tris(1,10-phenanthroline)ruthenium(II)-Na(2)SO(3)-permanganate, is described. This method is based on the CL reaction of estrogen benzoate (EB) with acidic potassium permanganate and tris(1,10-phenanthroline)ruthenium(II). The CL intensity is greatly enhanced when Na(2)SO(3) is added. After optimization of the different experimental parameters, a calibration graph for estrogen benzoate is linear in the range 0.05-10 µg/mL. The 3 s limit of detection is 0.024 µg/mL and the relative standard deviation was 1.3% for 1.0 µg/mL estrogen benzoate (n = 11). This proposed method was successfully applied to commercial injection samples and emulsion cosmetics. The mechanism of CL reaction was also studied. Copyright © 2011 John Wiley & Sons, Ltd.

  3. A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.

    Science.gov (United States)

    Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying

    2014-08-15

    Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. An ultrasensitive label-free electrochemiluminescent immunosensor for measuring Cry1Ab level and genetically modified crops content.

    Science.gov (United States)

    Gao, Hongfei; Wen, Luke; Wu, Yuhua; Fu, Zhifeng; Wu, Gang

    2017-11-15

    The development of genetically modified (GM) insect-resistant crops has aroused great public concern about the risks on the eco-environment resulting from a release of toxic Cry proteins (such as Cry1Ab) to the soil. Therefore, it is of crucial importance to measure the Cry proteins level and the GM crops content. Here, we have tested for the first time a method that uses novel carbon nanospheres (CNPs) label-free electrochemiluminescent (ECL) immunosensor for the ultrasensitive quantification of Cry1Ab and GM crops. In this work, novel CNPs were prepared from printer toner with a very facile approach, and linked with anti-Cry1Ab antibodies to modify a golden working electrode. The immunoreaction between Cry1Ab and its antibody formed an immunocomplex on the bioreceptor region of the sensor, which inhibited electron transfer between the electrode surface and the ECL substance, leading to a decrease of ECL response. Under the optimal conditions, the fabricated label-free ECL immunosensor determined Cry1Ab down to 3.0pgmL -1 within a linear range of 0.010-1.0ngmL -1 , showing significant improvement of sensitivity than that of most previous reports. Meanwhile, the proposed method was successfully applied for GM rice BT63 and GM maize MON810 detections down to 0.010% and 0.020%, respectively. Due to its outstanding advantages such as high sensitivity, ideal selectivity, simple fabrication, rapid detection, and low cost, the developed method can be considered as a powerful and pioneering tool for GM crops detection. Its use can also be extended to other toxin protein sensing in foods. Copyright © 2017. Published by Elsevier B.V.

  5. Cost-effective disposable thiourea film modified copper electrode for capacitive immunosensor

    International Nuclear Information System (INIS)

    Limbut, Warakorn; Thavarungkul, Panote; Kanatharana, Proespichaya; Wongkittisuksa, Booncharoen; Asawatreratanakul, Punnee; Limsakul, Chusak

    2010-01-01

    Cost-effective disposable electrodes were fabricated from copper clad laminate, usually used for printed circuit board (PCB) in electronic industries, by using dry film photoresist. Electro-oxidation (anodisation) was employed to obtain a good formation of thiourea film on the electrode surface. The affinity binding pair of carcinoembryonic antigen (CEA) and anti-carcinoembryonic antigen (anti-CEA) was used as a model system. Anti-CEA was immobilized on thiourea film via covalent coupling. This modified electrode was incorporated with a capacitive system for CEA analysis. This capacitive immunosensor provided a linear range between 0.01 and 10 ng ml -1 with a detection limit of 10 pg ml -1 . When applied to analyze CEA in serum samples, the results agreed well with the enzyme linked fluorescent assay (ELFA) technique (P > 0.05). The proposed strategy for the preparation of disposable modified copper electrode is very cost effective and simple. Moreover, it provides good reproducibility. This technique can easily be applied to immobilize other biological sensing elements for biosensors development.

  6. Ester oxidation on an aluminum surface using chemiluminescence

    Science.gov (United States)

    Jones, William R., Jr.; Meador, Michael A.; Morales, Wilfredo

    1986-01-01

    The oxidation characteristics of a pure ester (trimethyolpropane triheptanoate) were studied by using a chemiluminescence technique. Tests were run in a thin film microoxidation apparatus with an aluminum alloy catalyst. Conditions included a pure oxygen atmosphere and a temperature range of 176 to 206 C. Results indicated that oxidation of the ester (containing .001 M diphenylanthracene as an intensifier) was accompanied by emission of light. The maximum intensity of light emission was a function of the amount of ester, the concentration of intensifier, and the test temperature. The induction period, or the time to reach one-half of maximum intensity was inversely proportional to test temperature. Decreases in light emission at the later stages of a test were caused by depletion of the intensifier.

  7. Cathodic electrogenerated chemiluminescence of aromatic Tb(III) chelates at polystyrene-graphite composite electrodes

    International Nuclear Information System (INIS)

    Salminen, Kalle; Grönroos, Päivi; Tuomi, Sami; Kulmala, Sakari

    2017-01-01

    Tb(III) chelates exhibit intense hot electron-induced electrogenerated chemiluminescence during cathodic polarization of metal/polystyrene-graphite (M/PG) electrodes in fully aqueous solutions. The M/PG working electrode provides a sensitive means for the determination of aromatic Tb(III) chelates at nanomolar concentration levels with a linear log-log calibration curve spanning more than five orders of magnitude. The charge transport and other properties of these novel electrodes were studied by electrochemiluminescence measurements and cyclic voltammetry. The present composite electrodes can by utilized both under pulse polarization and DC polarization unlike oxide-coated metal electrodes which do not tolerate cathodic DC polarization. The present cost-effective electrodes could be utilized e.g. in immunoassays where polystyrene is extensively used as a solid phase for various bioaffinity assays by using electrochemiluminescent Tb(III) chelates or e.g. Ru(bpy) 3 2+ as labels. - Highlights: • Generation of hydrated electrons at Polystyrene-graphite electrodes. • The insulating polystyrene layer on the outer electrode surface seems necessary. • Hydrated electrons are able to produce chemiluminescence. • Strongest signal and lowest std. dev. achieved at same graphite weight fraction.

  8. Fabrication of an electrically conductive mixed self-assembled monolayer and its application in an electrochemical immunosensor

    International Nuclear Information System (INIS)

    Lee, Jung Bae; Namgung, Miok; Lee, Sang-Baek; Oh, Se Young

    2008-01-01

    Oligophenylethynylene thiol containing carboxylic acid in the tail group as a conducting wire bioreceptor was synthesized, and then its electrical property was investigated from the measurement of scanning tunneling microscopy (STM). Mixed self-assembled monolayer (SAM) consisting of 4-(2-(4-acetylthio)phenyl)ethynyl) benzoic acid (APBA) and butanethiol was fabricated in order to improve the electrical conductivity owing to the molecular orientation. We have examined the molecular orientation and the electrochemical activity of mixed SAM via X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry (CV). Especially, the prepared mixed SAM used as a bioreceptor in electrochemical prostate specific antigen (PSA) immunosensor showed higher electrochemical activity than that of the other SAMs

  9. A Label-Free and Ultrasensitive Immunosensor for Detection of Human Chorionic Gonadotrophin Based on Graphene FETs.

    Science.gov (United States)

    Islam, Kamrul; Suhail, Ahmed; Pan, Genhua

    2017-07-12

    We report on a label-free immunosensor based on graphene field effect transistors (G-FETs) for the ultrasensitive detection of Human Chorionic Gonadotrophin (hCG), as an indicator of pregnancy and related disorders, such as actopic pregnancy, choriocarcinoma and orchic teratoma. Pyrene based bioactive ester was non-covalently anchored onto the graphene channel in order to retain the sp² lattice. The G-FET transfer characteristics showed repeatable and reliable responses in all surface modifying steps using a direct current (DC) readout system. The hCG concentration gradient showed a detection limit of ~1 pg·mL -1 . The proposed method facilitates the cost-effective and viable production of graphene point-of-care devices for clinical diagnosis.

  10. Determination of vitamin C in drugs using of an optimized novel TCPO-Amplex red-gold/silver alloy nanoparticles-H{sub 2}O{sub 2} chemiluminescence method by the Box-Behnken design

    Energy Technology Data Exchange (ETDEWEB)

    Chaichi, M.J., E-mail: jchaichi@yahoo.com [Faculty of Chemistry, University of Mazandaran, Babolsar (Iran, Islamic Republic of); Alijanpour, S.O. [Faculty of Chemistry, University of Mazandaran, Babolsar (Iran, Islamic Republic of)

    2013-02-15

    Response surface methodology (RSM), based on a Box-Behnken design (BBD) was used to optimize three of the most important operating variables (concentrations of TCPO, Amplex red and pH effect) at peroxyoxalate-chemiluminescence (PO-CL) system. For the first time Amplex red (AR) was introduced as a new fluorescent emitter for predicting the reaction mechanism of PO-CL by means of the fluorescence property of its oxidation product. In optimum conditions, it was found that Au/Ag alloy nanoparticles (NPs) could enhance the CL intensity and the method sensitivity toward the evaluation of trace amount of vitamin C. Based on the antioxidant property of vitamin C noticeably the CL signal of the bis-(2,4,6-trichlorophenyl)oxalate-AR-NPs-hydrogen peroxide-sodium salicylate system was quenched in a low basic medium. A simple, rapid and sensitive CL method for the determination of vitamin C has been developed. The results showed a linear relationship between vitamin C concentration and PO-CL intensity in the range of 0.082-82.7 {mu}g/mL. Detection limit of 0.012 {mu}g/mL and the relative standard deviation (RSD)<4% was obtained. - Highlights: Black-Right-Pointing-Pointer The Box-Behnken design was used to optimize peroxyoxalate-chemiluminescence system. Black-Right-Pointing-Pointer Amplex red is as new fluorescent emitters for peroxyoxalate chemiluminescence. Black-Right-Pointing-Pointer It is introduce a method for determination of vitamin C. Black-Right-Pointing-Pointer Detection limit of vitamin C was obtained about 0.012 {mu}g/mL.

  11. Nanocomposites of gold nanoparticles and graphene oxide towards an stable label-free electrochemical immunosensor for detection of cardiac marker troponin-I.

    Science.gov (United States)

    Liu, Guozhen; Qi, Meng; Zhang, Yin; Cao, Chaomin; Goldys, Ewa M

    2016-02-25

    A stable label-free amperometric immunosensor is presented based on gold nanoparticles and graphene oxide nanocomposites for detection of cardiac troponin-I in the early diagnosis of myocardial infarction. For designing of the sensing platform, firstly the nanocomposites based on GO and AuNPs were prepared and anchored on electrode surfaces. The formed nanocomposites provided a platform with big surface area for loading anti-cTnI capture antibody, and worked as a bridge for fast electron transfer subsequently increased the sensitivity. Moreover, the linkages between AuNP, GO, and electrodes were based on covalent bonding by aryldiazonium salt coupling chemistry, which favors the stability of the sensing interface. Finally, the anti-cTnI detection antibody was immobilized on GO tailored with ferrocene molecules, functioning as the signal reporter for the detection of cTnI. The modification process was monitored using electrochemistry, SEM, XPS. The herein immunosensor demonstrates a good selectivity and high sensitivity against human-cTnI, and is capable of detecting cTnI at concentrations as low as 0.05 ng mL(-1), which is 100 times lower than that possible by conventional methods. It is potential to design the portable sensing platform based on AuNPs and GO nanocomposites for future point-of-care diagnostics. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. A comparative Study of Aptasensor Vs Immunosensor for Label-Free PSA Cancer Detection on GQDs-AuNRs Modified Screen-Printed Electrodes.

    Science.gov (United States)

    Srivastava, Monika; Nirala, Narsingh R; Srivastava, S K; Prakash, Rajiv

    2018-01-31

    Label-free and sensitive detection of PSA (Prostate Specific Antigen) is still a big challenge in the arena of prostate cancer diagnosis in males. We present a comparative study for label-free PSA aptasensor and PSA immunosensor for the PSA-specific monoclonal antibody, based on graphene quantum dots-gold nanorods (GQDs-AuNRs) modified screen-printed electrodes. GQDs-AuNRs composite has been synthesized and used as an electro-active material, which shows fast electron transfer and catalytic property. Aptamer or anti-PSA has immobilized onto the surface of modified screen printed electrodes. Three techniques are used simultaneously, viz. cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedence spectroscopy (EIS) to investigate the analytical performance of both PSA aptasensor and PSA immunosensor with its corresponding PSA antigen. Under optimum conditions, both sensors show comparable results with an almost same limit of detection (LOD) of 0.14 ng mL -1 . The results developed with aptasensor and anti-PSA is also checked through the detection of PSA in real samples with acceptable results. Our study suggests some advantages of aptasensor in terms of better stability, simplicity and cost effectiveness. Further our present work shows enormous potential of our developed sensors for real application using voltammetric and EIS techniques simultaneous to get reliable detection of the disease.

  13. Electrochemical Detecting Lung Cancer-Associated Antigen Based on Graphene-Gold Nanocomposite

    Directory of Open Access Journals (Sweden)

    Zheng Wei

    2017-03-01

    Full Text Available Using a Au nanoparticle/reduced graphene oxide composite (AuNP-RGO, a signal-enhanced electrochemical immunosensor without label was created to detect neuron-specific enolase (NSE. Furthermore, an environmentally-friendly method was developed to prepare AuNP-RGO by employing chitosan (CS, which served as reducing and stabilizing agent. We showed that the sensitivity of the immunosensor designed in this report was remarkably enhanced because of the numerous active sites in the sensor provided by the AuNP-RGO nanostructure. For the quantification of NSE, the immunosensor exhibited a positive linear relationship with the concentration in the range of 0.1 to 2000 ng/mL, where the limit of the detection was 0.05 ng/mL.

  14. Sensitive chemiluminescence immunoassay for staphylococcal enterotoxin C1 based on the use of dye-encapsulated mesoporous silica nanoparticles

    International Nuclear Information System (INIS)

    Tao, Liang; Zhang, Chunmei; Sun, Yuanjie; Jin, Boquan; Yang, Kun; Li, Xiaohua; Zhang, Zhujun; Zhang, Jinpeng; Yan, Kuocheng

    2016-01-01

    A chemiluminescent immunoassay for the staphylococcal enterotoxin C1 (SEC1) based on the use of dye-encapsulated mesoporous silica nanoparticles (m-SiNPs) as a label is described. The dyes are retained in the m-SiNPs via strong hydrophobic interactions. The assay comprises the following steps: (a) Microplates coated with antibody against SEC1 are filled with sample upon which the SEC antigen will be bound to the surface; (b) following a washing step, secondary antibody linked to m-SiNPs (that were covalently labeled with rhodamine 6G and fluorescein) were added to form the sandwich complex; (c) after another washing step, bis(2,4,6-trichlorophenyl) oxalate, H_2O_2 and imidazole are added to generate chemiluminescence whose intensity is proportional to the number of m-SiNPs and thus to the number of antigen (SEC) molecules. It is found that the use of functionalized m-SiNPs strongly amplifies the signal. Enterotoxin SEC1 can be detected by this method in the 0.025 to 2 ng⋅mL"-"1 concentration range, the detection limit is 19 pg⋅mL"-"1 (at 3σ), and the relative standard deviation (for 11 parallel measurements at a 1 ng⋅mL"-"1 level) is 4.6 %. The use of an automated chemiluminescence analyzer further improves detection. (author)

  15. An Immunosensor Based on Antibody Binding Fragments Attached to Gold Nanoparticles for the Detection of Peptides Derived from Avian Influenza Hemagglutinin H5

    Directory of Open Access Journals (Sweden)

    Urszula Jarocka

    2014-08-01

    Full Text Available This paper concerns the development of an immunosensor for detection of peptides derived from avian influenza hemagglutinin H5. Its preparation consists of successive gold electrode modification steps: (i modification with 1,6-hexanedithiol and gold colloidal nanoparticles; (ii immobilization of antibody-binding fragments (Fab’ of anti-hemagglutinin H5 monoclonal antibodies Mab 6-9-1 via S-Au covalent bonds; and (iii covering the remaining free space on the electrode surfaces with bovine serum albumin. The interactions between Fab’ fragments and hemagglutinin (HA variants have been explored with electrochemical impedance spectroscopy (EIS in the presence of [Fe(CN6]3−/4− as an electroactive marker. The immunosensor was able to recognize three different His-tagged variants of recombinant hemagglutinin from H5N1 viruses: H1 subunit (17–340 residues of A/swan/Poland/305-135V08/2006, the long HA (17–530 residues A/Bar-headed Goose/Qinghai/12/2005 and H1 subunit (1–345 residues of A/Vietnam/1194/2004. The strongest response has been observed for the long variant with detection limit of 2.2 pg/mL and dynamic range from 4.0 to 20.0 pg/mL.

  16. Phagocytic and chemiluminescent responses of mouse peritoneal macrophages to living and killed Salmonella typhimurium and other bacteria

    International Nuclear Information System (INIS)

    Tomita, T.; Blumenstock, E.; Kanegasaki, S.

    1981-01-01

    In the presence of luminol, resident as well as thioglycolate-induced and immunized macrophages emitted chemiluminescence more efficiently when the cells were exposed to living Salmonella typhimurium than when they were exposed to the same bacterium killed by ultraviolet light or heat. This phenomenon was observed whether or not the bacterium was opsonized. The different response to living and killed bacteria was also found with Escherichia coli, Pseudomonas aeruginosa, Proteus morganii, and Enterobacter aerogenes, but not with Shigella sonnei, Klebsiella pneumoniae, and Propionibacterium acnes. The results suggest that macrophages respond better to living, motile bacteria than to nonmotile or killed bacteria. The experimental results obtained with motility mutants of S. typhimurium, E. coli, and P. aeruginosa confirm that macrophages exposed to the motile bacteria emit chemiluminescence more efficiently and ingest the motile bacteria at a much faster rate than the nonmotile bacteria

  17. A regenerable piezoelectric immunosensor on the basis of electropolymerized polypyrrole for highly selective detection of Staphylococcal Enterotoxin A in foodstuffs

    International Nuclear Information System (INIS)

    Karaseva, Nadezhda; Ermolaeva, Tatyana

    2015-01-01

    Piezoelectric immunosensors have been developed for the determination of trace concentrations of Staphylococcal enterotoxin A (SEA) in foodstuff. Antibodies against SEA were covalently immobilized on an electropolymerized polypyrrole substrate on a gold electrode which warrants increased stability of the biolayer and sensitive detection. The calibration plot is linear in the 1–80 ng∙mL -1 SEA concentration range, the limit of detection is 0.4 ng∙mL -1 , and the time of analysis is <30 min. The sensor was successfully applied to quantify SEA in chicken meat and milk. (author)

  18. Fe3O4 and metal-organic framework MIL-101(Fe) composites catalyze luminol chemiluminescence for sensitively sensing hydrogen peroxide and glucose.

    Science.gov (United States)

    Qian Tang, Xue; Dan Zhang, Yi; Wei Jiang, Zhong; Mei Wang, Dong; Zhi Huang, Cheng; Fang Li, Yuan

    2018-03-01

    In this work, Fe 3 O 4 and metal-organic framework MIL-101(Fe) composites (Fe 3 O 4 /MIL-101(Fe)) was demonstrated to possess excellent catalytic property to directly catalyze luminol chemiluminescence without extra oxidants. We utilized Fe 3 O 4 /MIL-101(Fe) to develop a ultra-sensitive quantitative analytical method for H 2 O 2 and glucose. The possible mechanism of the chemiluminescence reaction had been investigated. Under optimal conditions, the relative chemiluminescence intensity was linearly proportional to the logarithm of H 2 O 2 concentration in the range of 5-150nM with a limit of detection of 3.7nM (signal-to-noise ratio = 3), and glucose could be linearly detected in the range from 5 to 100nM and the detection limit was 4.9nM (signal-to-noise ratio = 3). Furthermore, the present approach was successfully applied to quantitative determination of H 2 O 2 in medical disinfectant and glucose in human serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Application of UV-Vis spectrophotometric and chemiluminescent methods for the evaluation of the antioxidant action of curcumin

    Czech Academy of Sciences Publication Activity Database

    Stanchev, Stancho; Pencheva, I.; Konstantinov, S.; Obreshkova, D.; Hadjimitova, V.

    2012-01-01

    Roč. 77, č. 8 (2012), s. 1063-1069 ISSN 0352-5139 Institutional research plan: CEZ:AV0Z40550506 Keywords : curcumin * antioxidant * UV-Vis spectrophotometry * DNA complexation * chemiluminescence Subject RIV: CC - Organic Chemistry Impact factor: 0.912, year: 2012

  20. An Ultrasensitive Electrochemical Immunosensor for Alpha-Fetoprotein Using an Envision Complex-Antibody Copolymer as a Sensitive Label

    Science.gov (United States)

    Xiong, Ping; Gan, Ning; Cao, Yuting; Hu, Futao; Li, Tianhua; Zheng, Lei

    2012-01-01

    A novel strategy is presented for sensitive detection of alfa-fetoprotein (AFP), using a horseradish peroxidase (HRP)-functionalized Envision antibody complex (EVC) as the label. The Envision-AFP signal antibody copolymer (EVC-AFP Ab2) was composed of a dextran amine skeleton anchoring more than 100 molecules of HRP and 15 molecules of secondary antibody, and acted as a signal tag in the immunosensor. The sensor was constructed using the following steps: First, gold electrode (GE) was modified with nano-gold (AuNPs) by electro-deposition in HAuCl4 solution. The high affinity of the AuNPs surface facilitates direct formation of a self-assembled thiolated protein G layer. Next, the coated GE was incubated in a solution of AFP capture antibody (AFP Ab1); these antibodies attach to the thiolated protein G layer through their non-antigenic regions, leaving the antigen binding sites for binding of target analyte. Following a sandwich immunoreaction, an EVC-AFP Ab2-AFP-AFP Ab1 immunocomplex was formed on the electrode surface, allowing large amounts of HRP on the complex to produce an amplified electrocatalytic current of hydroquinone (HQ) in the presence of hydrogen peroxide (H2O2). Highly amplified detection was achieved, with a detection limit of 2 pg/mL and a linear range of 0.005–0.2 ng/mL for AFP in 10 μL undiluted serum; this is near or below the normal levels of most cancer biomarker proteins in human serum. Measurements of AFP in the serum of cancer patients correlated strongly with standard enzyme-linked immunosorbent assays. These easily fabricated EVC-modified immunosensors show excellent promise for future fabrication of bioelectronic arrays. By varying the target biomolecules, this technique may be easily extended for use with other immunoassays, and thus represents a versatile design route.

  1. A Label-Free and Ultrasensitive Immunosensor for Detection of Human Chorionic Gonadotrophin Based on Graphene FETs

    Directory of Open Access Journals (Sweden)

    Kamrul Islam

    2017-07-01

    Full Text Available We report on a label-free immunosensor based on graphene field effect transistors (G-FETs for the ultrasensitive detection of Human Chorionic Gonadotrophin (hCG, as an indicator of pregnancy and related disorders, such as actopic pregnancy, choriocarcinoma and orchic teratoma. Pyrene based bioactive ester was non-covalently anchored onto the graphene channel in order to retain the sp2 lattice. The G-FET transfer characteristics showed repeatable and reliable responses in all surface modifying steps using a direct current (DC readout system. The hCG concentration gradient showed a detection limit of ~1 pg·mL−1. The proposed method facilitates the cost-effective and viable production of graphene point-of-care devices for clinical diagnosis.

  2. Polymeric Flexible Immunosensor Based on Piezoresistive Micro-Cantilever with PEDOT/PSS Conductive Layer

    Directory of Open Access Journals (Sweden)

    Rui Zhao

    2018-02-01

    Full Text Available In this paper, a fully polymeric micro-cantilever with the surface passivation layer of parylene-C and the strain resistor of poly(3,4-ethylenedioxythiophene/poly (styrene sulfonate (PEDOT/PSS was proposed and demonstrated for immunoassays. By optimizing the design and fabrication of the polymeric micro-cantilever, a square resistance of 220 Ω/□ for PEDOT/PSS conductive layer have been obtained. The experimental spring constant and the deflection sensitivity were measured to be 0.017 N/m and 8.59 × 10−7 nm−1, respectively. The biological sensing performances of polymeric micro-cantilever were investigated by the immunoassay for human immunoglobulin G (IgG. The immunosensor was experimentally demonstrated to have a linear behavior for the detection of IgG within the concentrations of 10~100 ng/mL with a limit of detection (LOD of 10 ng/mL. The experimental results indicate that the proposed polymeric flexible conductive layer-based sensors are capable of detecting trace biological substances.

  3. Polymeric Flexible Immunosensor Based on Piezoresistive Micro-Cantilever with PEDOT/PSS Conductive Layer.

    Science.gov (United States)

    Zhao, Rui; Sun, Ying

    2018-02-03

    In this paper, a fully polymeric micro-cantilever with the surface passivation layer of parylene-C and the strain resistor of poly(3,4-ethylenedioxythiophene)/poly (styrene sulfonate) (PEDOT/PSS) was proposed and demonstrated for immunoassays. By optimizing the design and fabrication of the polymeric micro-cantilever, a square resistance of 220 Ω/□ for PEDOT/PSS conductive layer have been obtained. The experimental spring constant and the deflection sensitivity were measured to be 0.017 N/m and 8.59 × 10 -7 nm -1 , respectively. The biological sensing performances of polymeric micro-cantilever were investigated by the immunoassay for human immunoglobulin G (IgG). The immunosensor was experimentally demonstrated to have a linear behavior for the detection of IgG within the concentrations of 10~100 ng/mL with a limit of detection (LOD) of 10 ng/mL. The experimental results indicate that the proposed polymeric flexible conductive layer-based sensors are capable of detecting trace biological substances.

  4. An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads.

    Science.gov (United States)

    Tao, Xiaoqi; Jiang, Haiyang; Yu, Xuezhi; Zhu, Jinghui; Wang, Xia; Wang, Zhanhui; Niu, Lanlan; Wu, Xiaoping; Shen, Jianzhong

    2013-05-01

    A competitive, direct, chemiluminescent immunoassay based on a magnetic beads (MBs) separation and gold nanoparticles (AuNPs) labelling technique to detect chloramphenicol (CAP) has been developed. Horseradish peroxidase (HRP)-labelled anti-CAP monoclonal antibody conjugated with AuNPs and antigen-immobilized MBs were prepared. After optimization parameters of immunocomplex MBs, the IC50 values of chemiluminescence magnetic nanoparticles immunoassay (CL-MBs-nano-immunoassay) were 0.017 µg L(-1) for extract method I and 0.17 µg L(-1) for extract method II. The immunoassay with two extract methods was applied to detect CAP in milk. Comparison of these two extract methods showed that extract method I was advantageous in better sensitivity, in which the sensitivity was 10 times compared to that of extract method II, while extract method II was superior in simple operation, suitable for high throughout screen. The recoveries were 86.7-98.0% (extract method I) and 80.0-103.0% (extract method II), and the coefficients of variation (CVs) were all recovery with both extract methods and high correlation with traditional ELISA kit in milk system confirmed that the immunomagnetic assay based on AuNPs exhibited promising potential in rapid field screening for trace CAP analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Chemiluminescence ELISA for the detection of oxidative DNA base damage using anti-8-hydroxy-2'-deoxyguanosine antibody. Application to the detection of irradiated foods

    International Nuclear Information System (INIS)

    Kikuchi, Masahiro; Funayama, Tomoo; Sakashita, Tetsuya; Satoh, Katsuya; Narumi, Issay; Kobayashi, Yashihiko; Gunawardane, Chaminda R.; Alam, Md. Khorshed; Dzomir, A. Zainuri Mohd.; Pitipanaarachchi, Ramya C.; Hamada, Nobuyuki; Wada, Seiichi

    2007-01-01

    Since ionizing radiation is used for sterilizing or lowering the microbial content of foods as a means of reducing food losses and securing food safety, the development of versatile detection methods of irradiated foods is necessary for appropriate management. In an effort to distinguish between irradiated and non-irradiated food, a method based on the detection of oxidative DNA base damage using the chemiluminescence enzyme-linked immunosorbent assay (ELISA) with anti-8-hydroxy-2'-deoxyguanosine antibody was developed. In the course of optimizing the reaction conditions for the ELISA, a 30-mer synthetic oligonucleotide containing 8-hydroxyguanine (8-oxoG) was used. Under the optimized conditions, the correlation between chemiluminescence intensity and 8-oxoG content in oligonucleotides was obtained. It was shown that this chemiluminescence ELISA method could be applied to chicken, beef and pork that were irradiated with over 3 kGy. Twenty milligrams of a loaf of meat was sufficient to distinguish between irradiated and non-irradiated meat by this method. (author)

  6. Measurements of essential oil extract and antioxidant in Syrian Myrtus communis L. leaves using photo chemiluminescence assay

    International Nuclear Information System (INIS)

    Zayzafoon, G.; Odeh, A.; Mahzia, Y.

    2012-01-01

    The essential oil extracts and antioxidant measurements of Syrian Myrtus communis L. leaves as hydrophilic and hydrophobic existence species have been carried out. The plant leaves as a source of antioxidants was tested by the influence of its aqueous and essential oil extracts on the yield of photo chemiluminescence, PCL solution applying very sensitive and reliable method. By means of a photo chemiluminescence assay, it was possible to assess the total antioxidants capacity of hydrophilic and hydrophobic species existence in Syrian Myrtus communis L. leaves. It has been found that, the integral antioxidant capacity measurements value of Syrian Myrtus communis L. leaves was found in Kurdaha site which has a value of 465.67 1.18 nmol TE/g DM (total Trolox equivalent /gram of Dry material) . The following three mainly chemical species were found in the essential oil extracts: -Pinene, Cineole and Limonene. (author)

  7. Application of Box–Behnken design in the optimization of new peroxyoxalate–H2O2 chemiluminescence system using furan derivatives as blue activators

    International Nuclear Information System (INIS)

    Chaichi, M.J.; Azizi, S.N.; Alijanpour, O.; Heidarpour, M.; Qandalee, M.

    2013-01-01

    The non-commercially synthesized and purified furan derivatives are of great interest as fluorescent emitters for peroxyoxalate chemiluminescence (PO-CL). The reaction of oxalic ester such as bis-(2,4,6-trichloro-phenyl) oxalate (TCPO) with H 2 O 2 can lead to the excitation of an appropriate activator via the formation of a 1,2-dioxetanedione intermediate. In this study, two furan derivatives were used as activators which produce a blue light in the chemiluminescence systems. In the following, the Box–Behnken design matrix and response surface methodology (RSM) have been applied to design the experiments to study the relationship between the chemiluminescence intensities and the three most important operating variables such as sodium salicylate (5×10 −4 –5×10 −3 M), furan (10 −5 –10 −3 M) and hydrogen peroxide (10 −3 –10 −1 M) concentrations, and also to evaluate the interactive effects of these variables on the CL emission of TCPO system. Totally 15 experiments were conducted in the present study towards the construction of a quadratic model. Independent variables of sodium salicylate, hydrogen peroxide and furan concentration have the significance value of p=0.05, in both the systems, which explicitly shows the importance of these variables in the CL emission of TCPO. Values of Prob>F less than 0.0001 indicated that the model terms are significant for the CL emission of TCPO. Moreover, the regression equation coefficients were calculated and the data fitted to a second-order polynomial equation for CL emission of TCPO. -- Highlights: ► Furan derivatives are used as activators for peroxyoxalate chemiluminescence. ► The activators produce a blue light in the chemiluminescence system. ► The Box–Behnken design matrix and response surface methodology (RSM) is used. ► The most important variables are sodium salicylate, furan and hydrogen peroxide. ► The data are fitted to a second-order polynomial equation for CL emission of TCPO

  8. Simplex optimization of the variables influencing the determination of pefloxacin by time-resolved chemiluminescence

    Science.gov (United States)

    Murillo Pulgarín, José A.; Alañón Molina, Aurelia; Jiménez García, Elisa

    2018-03-01

    A new chemiluminescence (CL) detection system combined with flow injection analysis (FIA) for the determination of Pefloxacin is proposed. The determination is based on an energy transfer from Pefloxacin to terbium (III). The metal ion enhances the weak CL signal produced by the KMnO4/H2SO3/Pefloxacin system. A modified simplex method was used to optimize chemical and instrumental variables. The influence of the interaction of the permanganate, Tb (III), sodium sulphite and sulphuric acid concentrations, flow rate and injected sample volume was thoroughly investigated by using a modified simplex optimization procedure. The results revealed a strong direct relationship between flow rate and CL intensity throughout the studied range that was confirmed by a gamma test. The response factor for the CL emission intensity was used to assess performance in order to identify the optimum conditions for maximization of the response. Under such conditions, the CL response was proportional to the Pefloxacin concentration over a wide range. The detection limit as calculated according to Clayton's criterion 13.7 μg L- 1. The analyte was successfully determined in milk samples with an average recovery of 100.6 ± 9.8%.

  9. A Miniaturized Impedimetric Immunosensor for the Competitive Detection of Adrenocorticotropic Hormone

    Directory of Open Access Journals (Sweden)

    Nan Li

    2017-12-01

    Full Text Available Adrenocorticotropic hormone (ACTH plays an essential role in regulating corticosteroid hormone production, which has important functions in a myriad of critical physiological functions. In this proof-of-concept study, a miniaturized immunosensor was developed for the highly sensitive detection of ACTH using electrochemical impedance spectroscopy (EIS in connection with disposable screen-printed gold electrodes (SPGEs. A film of 3,3′-dithiobis[sulfosuccinimidylpropionate] (DTSSP was prepared to immobilize anti-ACTH antibodies covalently on the nanostructured SPGE surface. The surface-immobilized anti-ACTH antibodies captured the biotinylated ACTH (biotin-ACTH and non-labelled ACTH for the competitive immunoassay. After coupling of a streptavidin-alkaline phosphatase conjugate (Streptavidin-ALP, the bio-catalysed precipitation of an insoluble and insulating product onto the sensing interface changed the charge transfer resistance (Rct characteristics significantly. The detection limit of 100 fg/mL was determined for ACTH in a 5 μL sample volume, which indicated that this versatile platform can be easily adapted for miniaturized electrochemical immunosensing of cancer marker biomolecules. High selectivity and sensitivity of our immunoassay to detect ACTH in real samples demonstrated its promising potential for future development and applications using clinical samples.

  10. Sensitivity Improvement of an Impedimetric Immunosensor Using Functionalized Iron Oxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    Imen Hafaid

    2009-01-01

    Full Text Available This work has explored the development of impedimetric immunosensors based on magnetic iron nanoparticles (IrNP functionalized with streptavidin to which a biotinylated FAB part of the antibody has been bound using a biotin-streptavidin interaction. SPR analysis shows a deviation on the measured (angle during antigen-antibody recognition whereas label free detection using by EIS allows us to monitor variation of polarization resistance. Before detection, layers were analyzed by FTIR and AFM. Compared to immobilization of antibody on bare gold surface using aminodecanethiol SAM, antibody immobilization on nanoparticles permitted to reach lower detection limit: 500 pg/ml instead of 1 ng/ml to in the case of EIS and 300 ng/ml instead of 4.5 μg/ml in the case of SPR. Thus, it permitted to improve the sensitivity: from 257.3  Ω⋅cm2⋅μg−1⋅ml to 1871 Ω⋅cm2⋅μg−1⋅ml in the case of EIS and from 0.003°μg−1⋅ml to 0.094°μg−1⋅ml in the case of SPR.

  11. The application of automatic chemiluminescence machine in rapid immune detection

    International Nuclear Information System (INIS)

    Lin Aizhen; Li Xuanwei; Chen Binhong; Li Zhenqian; Chen Zhaoxuan

    2004-01-01

    Objective: To provide high-quality, rapid and dependable result for clinical practice, and give satisfactory service to patients of different economical status by supplementation with other labeling immune examination. With an innovative attitude, we carried out efficient technical reform on ACS180 automatic chemiluminescence machine, making it possible for patients to complete the whole process including examination, check-out, diagnosis and getting drugs. The reported will be issued within an hour, thus a rapid immune detection service was established in out-patients department. Methods: 1. ACS-180 automatic chemiluminescence machine is used based on the principle of chemiluminescence immune methods. 2. The reagents are provided by Ciba-Comig Company of USA, composed of anti acridinium ester antibody of liquid phase and particulate antigen of solid phase wrapped in magnetic powder. 3. Calibration and quality control: high and low concentration are set for each calibration fluid with attached standard curve. Product for quality controlling includes three concentration of low, moderate and high. Results: 1. rapid machine detection for sample: serum is replaced with plasma coagulated by heparin, and comparison among series of methods using serum or plasma suggest no significant difference exists. 2. The problem about fasting detection: chemiluminescence machine measure optical density directly, with the results hardly being influenced by turbidity. But attention should be paid to the treatment of lipid turbid samples. 3. Other innovations: (1) direct placement of sample tube on machine: a cushion is placed on sample plate to transfer sample to machine directly after centrifugation, saving time and reducing the accident in sample transference. (2) for HCG quantification in blood and urine, 'gold criteria' is used firstly in screening to determine approximately the dilution range, with an advantage of saving time and reagent as well as accuracy. (3) we design a

  12. Conglutinin exhibits a complement-dependent enhancement of the respiratory burst of phagocytes stimulated by E. coli

    DEFF Research Database (Denmark)

    Friis, P; Svehag, S E; Andersen, Ove

    1991-01-01

    . Conglutinin enhances, in a dose-dependent manner, the respiratory burst of spleen cells stimulated with serum-opsonized Escherichia coli. The enhancement was only demonstrable in the presence of a functional complement system. The conglutinin-mediated enhancement of the respiratory burst was inhibited......Conglutinin is a mammalian C-type lectin which shows anti-bacterial activity when tested in vivo and in vitro. This study concerns the effect of conglutinin on the respiratory burst of murine spleen cells, using a chemiluminescence assay for measurement of generated reactive oxygen metabolites...

  13. Simultaneous determination of chromium(III) and chromium(VI) in aqueous solutions by ion chromatography and chemiluminescence detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jøns, O; Nielsen, B

    1992-01-01

    A method for the simultaneous determination of chromium(iii) and chromium(vi) in a flow system based on chemiluminescence was developed. A Dionex cation-exchange guard column was used to separate chromium(iii) from chromium(vi), and chromium(vi) was reduced by potassium sulfite, whereupon both...

  14. New competitive dendrimer-based and highly selective immunosensor for determination of atrazine in environmental, feed and food samples: the importance of antibody selectivity for discrimination among related triazinic metabolites.

    Science.gov (United States)

    Giannetto, Marco; Umiltà, Eleonora; Careri, Maria

    2014-01-02

    A new voltammetric competitive immunosensor selective for atrazine, based on the immobilization of a conjugate atrazine-bovine serum albumine on a nanostructured gold substrate previously functionalized with poliamidoaminic dendrimers, was realized, characterized, and validated in different real samples of environmental and food concern. Response of the sensor was reliable, highly selective and suitable for the detection and quantification of atrazine at trace levels in complex matrices such as territorial waters, corn-cultivated soils, corn-containing poultry and bovine feeds and corn flakes for human use. Selectivity studies were focused on desethylatrazine, the principal metabolite generated by long-term microbiological degradation of atrazine, terbutylazine-2-hydroxy and simazine as potential interferents. The response of the developed immunosensor for atrazine was explored over the 10(-2)-10(3) ng mL(-1) range. Good sensitivity was proved, as limit of detection and limit of quantitation of 1.2 and 5 ng mL(-1), respectively, were estimated for atrazine. RSD values <5% over the entire explored range attested a good precision of the device. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer

    Directory of Open Access Journals (Sweden)

    Xiaoling Fu

    2018-03-01

    Full Text Available The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA was presented for the clinical determination and analysis of human epididymis protein 4 (HE4 in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0–1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA, with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum. Keywords: Chemiluminescence immunoassay, Magnetic particles, Human epididymis protein 4

  16. Chemiluminescence response of whole blood and separated blood cells in cases of experimentally induced pancreatitis and MDTQ-DA-Trasylol-ascorbic acid therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, T.; Schuster, R.; Lauschke, G.; Trausch, M. (Medical Academy of Dresden (Germany). Department of Surgery); Albrecht, S. (Medical Academy of Dresden (Germany). Institute of Clinical Chemistry); Kopprasch, S.; Kuehne, H. (Medical Academy of Dresden (Germany). Institute of Pathological Biochemistry)

    1991-12-24

    The formation of reactive O{sub 2} species in the pancreas of pigs after induction of necrotizing or oedematous pancreatitis was studied by means of luminol- and lucigenin-sensitized chemiluminescence. The effect of 2,2-dimethyl-4-methanesulphonic acid-1,2-dihydroquinoline in combination with Trasylol and ascorbic acid was studied in vivo. This combined therapy leads to a reduction in the chemiluminescence response by 50-70% with prevention of pancreatogenic shock and multiple organ failure by improvement of the gluthathione status. A combination of radical traps, kallikrein inhibitors and natural antioxidative sub-stances is an efficient alternative therapy in cases of acute pancrea-titis. (author). 10 refs.; 5 figs.

  17. Effective antibodies immobilization and functionalized nanoparticles in a quartz-crystal microbalance-based immunosensor for the detection of parathion.

    Directory of Open Access Journals (Sweden)

    Bartolomeo Della Ventura

    Full Text Available Biosensor-based detection provides a rapid and low-cost alternative to conventional analytical methods for revealing the presence of the contaminants in water as well as solid matrices. Although important to be detected, small analytes (few hundreds of Daltons are an issue in biosensing since the signal they induce in the transducer, and specifically in a Quartz-Crystal Microbalance, is undetectable. A pesticide like parathion (M = 292 Da is a typical example of contaminant for which a signal amplification procedure is desirable.The ballasting of the analyte by gold nanoparticles has been already applied to heavy target as proteins or bacteria to improve the limit of detection. In this paper, we extend the application of such a method to small analytes by showing that once the working surface of a Quartz-Crystal Microbalance (QCM has been properly functionalized, a limit of detection lower than 1 ppb is reached for parathion. The effective surface functionalization is achieved by immobilizing antibodies upright oriented on the QCM gold surface by a simple photochemical technique (Photonic Immobilization Technique, PIT based on the UV irradiation of the antibodies, whereas a simple protocol provided by the manufacturer is applied to functionalize the gold nanoparticles. Thus, in a non-competitive approach, the small analyte is made detectable by weighing it down through a "sandwich protocol" with a second antibody tethered to heavy gold nanoparticles. The immunosensor has been proved to be effective against the parathion while showing no cross reaction when a mixture of compounds very similar to parathion is analyzed.The immunosensor described in this paper can be easily applied to any small molecule for which polyclonal antibodies are available since both the functionalization procedure of the QCM probe surface and gold nanoparticle can be applied to any IgG, thereby making our device of general application in terms of target analyte.

  18. An electrochemical immunosensor based on chemical assembly of vertically aligned carbon nanotubes on carbon substrates for direct detection of the pesticide endosulfan in environmental water.

    Science.gov (United States)

    Liu, Guozhen; Wang, Shuo; Liu, Jingquan; Song, Dandan

    2012-05-01

    A glassy carbon substrate was covalently modified with a mixed layer of 4-aminophenyl and phenyl via in situ electrografting of their aryldiazonium salts in acidic solutions. Single-walled carbon nanotubes (SWNTs) were covalently and vertically anchored on the electrode surface via the formation of amide bonds from the reaction between the amines located on the modified substrate and the carboxylic groups at the ends of the nanotubes. Ferrocenedimethylamine (FDMA) was subsequently attached to the ends of SWNTs through amide bonding followed by the attachment of an epitope, i.e., endosulfan hapten to which an antibody would bind. Association or dissociation of the antibody with the sensing interface causes a modulation of the ferrocene electrochemistry. Antibody-complexed electrodes were exposed to samples containing spiked endosulfan (unbound target analyte) in environment water and interrogated using the square wave voltammetry (SWV) technique. The modified sensing surfaces were characterized by atomic force microscopy, XPS, and electrochemistry. The fabricated electrochemical immunosensor can be successfully used for the detection of endosulfan over the range of 0.01-20 ppb by a displacement assay. The lowest detection limit of this immunosensor is 0.01 ppb endosulfan in 50 mM phosphate buffer at pH 7.0.

  19. Sensitive and selective determination of fluvoxamine maleate using a sensitive chemiluminescence system based on the alkaline permanganate-Rhodamine B-gold nanoparticles reaction.

    Science.gov (United States)

    Hassanzadeh, Javad; Amjadi, Mohammad

    2015-06-01

    A high-yield chemiluminescence (CL) system based on the alkaline permanganate-Rhodamine B reaction was developed for the sensitive determination of fluvoxamine maleate (Flu). Rhodamine B is oxidized by alkaline KMnO4 and a weak CL emission is produced. It was demonstrated that gold nanoparticles greatly enhance this CL emission due to their interaction with Rhodamine B molecules. It is also observed that sodium dodecyl sulfate, an anionic surfactant, can strongly increase this enhancement. In addition, it was demonstrated that a notable decrease in the CL intensity is observed in the presence of Flu. This may be related to Flu oxidation with KMnO4 . There is a linear relationship between the decrease in CL intensity and the Flu concentration over a range of 2-300 µg/L. A new simple, rapid and sensitive CL method was developed for the determination of Flu with a detection limit (3s) of 1.35 µg/L. The proposed method was used for the determination of Flu in pharmaceutical and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Highly sensitive trivalent copper chelate–luminol chemiluminescence system for capillary electrophoresis chiral separation and determination of ofloxacin enantiomers in urine samples

    Directory of Open Access Journals (Sweden)

    Hao-Yue Xie

    2014-12-01

    Full Text Available A simple, fast and sensitive capillary electrophoresis (CE strategy combined with chemiluminescence (CL detection for analysis of ofloxacin (OF enantiomers was established in the present work. Sulfonated β-cyclodextrin (β-CD was used as the chiral additive being added into the running buffer of luminol–diperiodatocuprate (III (K5[Cu(HIO62], DPC chemiluminescence system. Under the optimum conditions, the proposed method was successfully applied to separation and analysis of OF enantiomers with the detection limits (S/N=3 of 8.0 nM and 7.0 nM for levofloxacin and dextrofloxacin, respectively. The linear ranges were both 0.010–100 μM. The method was utilized for analyzing OF in urine; the results obtained were satisfactory and recoveries were 89.5–110.8%, which demonstrated the reliability of this method. This approach can also be further extended to analyze different commercial OF medicines. Keywords: Ofloxacin, Chiral analysis, Sulfonated-β-CD, Capillary electrophoresis, Chemiluminescence

  1. СHANGES IN PARAMETERS OF LUMINOL-DEPENDENT AND LUCIGENIN-DEPENDENT CHEMILUMINESCENCE OF PERIPHERAL BLOOD NEUTROPHILS IN PATIENTS WITH BLADDER CANCER IN THE DISEASE DYNAMICS

    Directory of Open Access Journals (Sweden)

    L. M. Kurtasova

    2015-01-01

    Full Text Available The study deals with parameters of luminol-dependent and lucigenin-dependent chemiluminescence (CL of peripheral blood neutrophils from patients with bladder cancer (BC prior to surgical treatment. We examined sixty patients (45 to 55 years old with advanced bladder cancer (TNM prior to the operation, and forty-six patients at 10 days after surgical treatment. A control group consisted of 56 healthy donors. Luminol-dependent and lucigenin-dependent chemiluminescence of blood neutrophils was assessed according to De Sole et al. (1983. Chemiluminescence assays of peripheral blood neutrophils from the patients with bladder cancer revealed changes in production of reactive oxygen species (ROS, both for initial stage of oxidation reaction, and total level of active oxygen radicals. We have found disturbed values of primary-to-secondary ROS ratio in the cells. In the patients with bladder cancer, some changes in oxidative metabolism of the blood neutrophils have been registered. These alterations may play an important role in promotion of potential effector cell functions, thus, probably, affecting the whole-scale development of a cytopathic effect exerted by neutrophilic granulocytes. 

  2. Egg-Citing! Isolation of Protoporphyrin IX from Brown Eggshells and Its Detection by Optical Spectroscopy and Chemiluminescence

    Science.gov (United States)

    Dean, Michelle L.; Miller, Tyson A.; Bruckner, Christian

    2011-01-01

    A simple and cost-effective laboratory experiment is described that extracts protoporphyrin IX from brown eggshells. The porphyrin is characterized by UV-vis and fluorescence spectroscopy. A chemiluminescence reaction (peroxyoxalate ester fragmentation) is performed that emits light in the UV region. When the porphyrin extract is added as a fluor…

  3. Application of Box–Behnken design in the optimization of new peroxyoxalate–H{sub 2}O{sub 2} chemiluminescence system using furan derivatives as blue activators

    Energy Technology Data Exchange (ETDEWEB)

    Chaichi, M.J., E-mail: jchaichi@yahoo.com [Faculty of Chemistry, Mazandaran University, Babolsar (Iran, Islamic Republic of); Azizi, S.N.; Alijanpour, O.; Heidarpour, M. [Faculty of Chemistry, Mazandaran University, Babolsar (Iran, Islamic Republic of); Qandalee, M. [Department of Biology, Garmsar Branch, Islamic Azad University, Garmsar (Iran, Islamic Republic of)

    2013-06-15

    The non-commercially synthesized and purified furan derivatives are of great interest as fluorescent emitters for peroxyoxalate chemiluminescence (PO-CL). The reaction of oxalic ester such as bis-(2,4,6-trichloro-phenyl) oxalate (TCPO) with H{sub 2}O{sub 2} can lead to the excitation of an appropriate activator via the formation of a 1,2-dioxetanedione intermediate. In this study, two furan derivatives were used as activators which produce a blue light in the chemiluminescence systems. In the following, the Box–Behnken design matrix and response surface methodology (RSM) have been applied to design the experiments to study the relationship between the chemiluminescence intensities and the three most important operating variables such as sodium salicylate (5×10{sup −4}–5×10{sup −3} M), furan (10{sup −5}–10{sup −3} M) and hydrogen peroxide (10{sup −3}–10{sup −1} M) concentrations, and also to evaluate the interactive effects of these variables on the CL emission of TCPO system. Totally 15 experiments were conducted in the present study towards the construction of a quadratic model. Independent variables of sodium salicylate, hydrogen peroxide and furan concentration have the significance value of p=0.05, in both the systems, which explicitly shows the importance of these variables in the CL emission of TCPO. Values of Prob>F less than 0.0001 indicated that the model terms are significant for the CL emission of TCPO. Moreover, the regression equation coefficients were calculated and the data fitted to a second-order polynomial equation for CL emission of TCPO. -- Highlights: ► Furan derivatives are used as activators for peroxyoxalate chemiluminescence. ► The activators produce a blue light in the chemiluminescence system. ► The Box–Behnken design matrix and response surface methodology (RSM) is used. ► The most important variables are sodium salicylate, furan and hydrogen peroxide. ► The data are fitted to a second-order polynomial

  4. Chemiluminescent determination of vanadium(IV) using a cinchomeronic hydrazide-H2O2 system and flow injection analysis

    International Nuclear Information System (INIS)

    Pradana Perez, J.A.; Alegria, J.S. Durand; Hernando, P. Fernandez; Sierra, A. Narros

    2005-01-01

    This paper proposes a new chemiluminescent flow injection analysis (FIA) method for the determination of vanadium(IV) ions in aqueous media. The method is based on the chemiluminescent reaction that occurs between cinchomeronic hydrazide (CH) and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. The chemical and physical variables involved in the flow injection system are optimised using a modified simplex method. Vanadium ions can be detected in the 0.08 and 1.00 μg mL -1 range; the detection limit for a signal-to-noise ratio of 3 is 0.08 μg mL -1 . Great variations in the quantum yield were observed when cobalt(II), chromium(III), copper(II) and/or nickel(II) were present in the reaction medium. The proposed method is selective and simple, and can be successfully used to analyse water samples without the need for separation or preconcentration processes

  5. A Novel Method for Preparation of Gold NanoBipyramids Using Microwave Irradiation and Its Application in Immunosensors

    Science.gov (United States)

    Huynh, Trong Phat; Ngo, Vo Ke Thanh; Nguyen, Dang Giang; Nguyen, Hoang Phuong Uyen; Nghiem, Quoc Dat; Lam, Quang Vinh; Huynh, Thanh Dat

    2016-05-01

    Gold nanobipyramids (NBPs) have attracted attention for producing smart sensing devices as diagnostic tools in biotechnological and medical applications, because they show more advantageous plasmonic properties than comparable gold nanorods. Normally, NBPs were synthesized using seed-mediated growth process at room temperature. In this report, our group describes a method for synthesising of NBPs using microwave irradiation with ascorbic acid reduction and cetyltrimethylammonium bromide + silver nitrate (AgNO3) as capping agents. The advantages of this method are a highly effective approach to fast and uniform NBPs. The product was characterized by ultraviolet-visible spectroscopy, Fourier transform infrared spectroscopy, transmission electron microscopy, and x-ray powder diffraction. As an application in quartz crystal microbalance immunosensors, NBPs is conjugated with the chloramphenicol antibodies for signal amplification to detect chloramphenicol residuals in the QCM system.

  6. Electrochemical magneto immunosensor based on endogenous β-galactosidase enzyme to determine enterotoxicogenic Escherichia coli F4 (K88) in swine feces using square wave voltammetry.

    Science.gov (United States)

    Viviana Tarditto, Lorena; Alicia Zon, María; García Ovando, Hugo; Roberto Vettorazzi, Nelio; Javier Arévalo, Fernando; Fernández, Héctor

    2017-11-01

    Diseases caused by enterotoxicogenic Escherichia coli F4 (K88) (ETEC F4) are a problem in swine production establishments. Due to the high rate of mortality and morbidity of E. coli infections, a rapid and accurate diagnosis is important in order to choose an appropriate treatment to reduce the economic impact. Therefore, an electrochemical magneto-immunosensor (EMI) was developed to detect and quantify ETEC F4 in swine feces samples through a direct non-competitive immunoassay. ETEC F4 was selectively captured by immunomagnetic separation. The detection principle was based on the activity of β-galactosidase endogenous enzyme (β-gal), which hydrolyses the p-aminophenyl-β-D-galactopyranoside (p-APG) producing p-aminophenol (p-AP), which was oxidized on a carbon screen printed electrode (CSPE) using square wave voltammetry (SWV). All parameters related to construction and electrochemical responses were optimized. The total analysis time to quantify ETEC F4 using the EMI was less than 2h and the limit of detection (LOD) was 33CFUmL -1 . The perceptual relative error (%E r ) was 20%. The magneto-immunosensor was validated versus conventional method of culture and plate count, obtaining a very good agreement. The EMI is simple, fast and economical to detect and quantify ETEC F4 in swine feces samples, being thus a valuable tool in swine production. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF

    Science.gov (United States)

    Wu, Yi; Modica, Vincent; Yu, Xilong; Li, Fei; Grisch, Frédéric

    2018-01-01

    The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.

  8. Effects of Non-Equilibrium Plasmas on Low-Pressure, Premixed Flames. Part 1: CH* Chemiluminescence, Temperature, and OH

    Science.gov (United States)

    2018-01-16

    Adamovich, Jeffrey A. Sutton1 Department of Mechanical and Aerospace Engineering , Ohio State University Abstract In this paper, we... chemistry . Qualitative imaging of CH* chemiluminescence indicates that during plasma discharge, the luminous flame zone is shifted upstream towards...Sutton Department of Mechanical and Aerospace Engineering , Ohio State University 1. Introduction In recent years, considerable interest has

  9. Chemiluminescence of graphene quantum dots and its application to the determination of uric acid

    International Nuclear Information System (INIS)

    Amjadi, Mohammad; Manzoori, Jamshid L.; Hallaj, Tooba

    2014-01-01

    We report on the chemiluminescence (CL) of graphene quantum dots (GQDs) induced by direct chemical oxidation. GQDs were prepared by a simple carbonization method and characterized by X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy and Raman spectroscopy. It was found that Ce(IV) could oxidize GQDs to produce a relatively intense CL emission. The mechanism of CL generation was investigated based on the fluorescence and CL emission spectra. It was attributed to the radiative recombination of oxidant-injected holes and thermally excited electrons in the GQDs. In order to show the analytical application potential of GQDs-Ce(IV) CL system, it was applied to the determination of uric acid. Under the optimized conditions, the proposed CL system exhibited excellent analytical performance for determination of uric acid in the range of 1.0×10 −6 M–5.0×10 −4 M with a limit of detection of 5.0×10 −7 M. The method was applied to the determination of uric acid in human plasma and urine samples, with satisfactory results. - Highlights: • Chemiluminescence of graphene quantum dots by direct oxidation was studied. • Intense CL is produced by reaction of graphene quantum dots with Ce(IV). • The new CL system was applied to determination of uric acid in plasma and urine

  10. Chemiluminescence of graphene quantum dots and its application to the determination of uric acid

    Energy Technology Data Exchange (ETDEWEB)

    Amjadi, Mohammad, E-mail: amjadi@tabrizu.ac.ir; Manzoori, Jamshid L.; Hallaj, Tooba

    2014-09-15

    We report on the chemiluminescence (CL) of graphene quantum dots (GQDs) induced by direct chemical oxidation. GQDs were prepared by a simple carbonization method and characterized by X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy and Raman spectroscopy. It was found that Ce(IV) could oxidize GQDs to produce a relatively intense CL emission. The mechanism of CL generation was investigated based on the fluorescence and CL emission spectra. It was attributed to the radiative recombination of oxidant-injected holes and thermally excited electrons in the GQDs. In order to show the analytical application potential of GQDs-Ce(IV) CL system, it was applied to the determination of uric acid. Under the optimized conditions, the proposed CL system exhibited excellent analytical performance for determination of uric acid in the range of 1.0×10{sup −6} M–5.0×10{sup −4} M with a limit of detection of 5.0×10{sup −7} M. The method was applied to the determination of uric acid in human plasma and urine samples, with satisfactory results. - Highlights: • Chemiluminescence of graphene quantum dots by direct oxidation was studied. • Intense CL is produced by reaction of graphene quantum dots with Ce(IV). • The new CL system was applied to determination of uric acid in plasma and urine.

  11. Microplate-reader method for the rapid analysis of copper in natural waters with chemiluminescence detection

    Directory of Open Access Journals (Sweden)

    Axel eDurand

    2013-01-01

    Full Text Available We have developed a method for the determination of copper in natural waters at nanomolar levels. The use of a microplate-reader minimises sample processing time (~ 25 sec per sample, reagent consumption (~ 120 μL per sample and sample volume (~ 700 μL. Copper is detected by chemiluminescence. This technique is based on the formation of a complex between copper and 1,10-phenanthroline and the subsequent emission of light during the oxidation of the complex by hydrogen peroxide. Samples are acidified to pH 1.7 and then introduced directly into a 24-well plate. Reagents are added during data acquisition via two reagent injectors. When trace metal clean protocols are employed, the reproducibility is generally less then 7% on blanks and the detection limit is 0.7 nM for seawater and 0.4 nM for freshwater. More than 100 samples per hour can be analyzed with this technique, which is simple, robust, and amenable to at-sea analysis. Seawater samples from Storm Bay in Tasmania illustrate the utility of the method for environmental science. Indeed other trace metals for which optical detection methods exist (e.g. chemiluminescence, fluorescence and absorbance could be adapted to the microplate-reader.

  12. Sonochemical fabrication of 8-hydroxyquinoline aluminum (Alq3) nanoflowers with high electrogenerated chemiluminescence.

    Science.gov (United States)

    Mao, Chang-Jie; Wang, Dan-Chen; Pan, Hong-Cheng; Zhu, Jun-Jie

    2011-03-01

    Well-defined Alq(3) nanoflowers were fabricated via a facile and fast sonochemical route. X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), field-emission scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and shape of the as-prepared product. The results showed that the resulting Alq(3) was composed of nanobelts with thickness about 50 nm, average widths of 200 nm, and length up to 10 μm. The Alq(3) nanoflowers exhibited good electrogenerated chemiluminescence behavior. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Flow-injection system for automated dissolution testing of isoniazid tablets with chemiluminescence detection.

    Science.gov (United States)

    Li, B; Zhang, Z; Liu, W

    2001-05-30

    A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.

  14. The sandwich-type electrochemiluminescence immunosensor for {alpha}-fetoprotein based on enrichment by Fe{sub 3}O{sub 4}-Au magnetic nano probes and signal amplification by CdS-Au composite nanoparticles labeled anti-AFP

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Hankun [State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering of Ningbo University, Ningbo 315211 (China); Gan Ning, E-mail: ganning@nbu.edu.cn [State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering of Ningbo University, Ningbo 315211 (China); Li Tianhua; Cao Yuting; Zeng Saolin [State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering of Ningbo University, Ningbo 315211 (China); Zheng Lei, E-mail: nfyyzl@163.com [Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Guo Zhiyong [State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering of Ningbo University, Ningbo 315211 (China)

    2012-10-09

    Highlights: Black-Right-Pointing-Pointer Sandwich immunoreaction, testing a large number of samples simultaneously. Black-Right-Pointing-Pointer The magnetic separation and enrichment by Fe{sub 3}O{sub 4}-Au magnetic nano probes. Black-Right-Pointing-Pointer The amplification of detection signal by CdS-Au composite nanoparticles labeled anti-AFP. Black-Right-Pointing-Pointer Almost no background signal, which greatly improve the sensitivity of detection. - Abstract: A novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated on a glassy carbon electrode (GCE) for ultra trace levels of {alpha}-fetoprotein (AFP) based on sandwich immunoreaction strategy by enrichment using magnetic capture probes and quantum dots coated with Au shell (CdS-Au) as the signal tag. The capture probe was prepared by immobilizing the primary antibody of AFP (Ab1) on the core/shell Fe{sub 3}O{sub 4}-Au nanoparticles, which was first employed to capture AFP antigens to form Fe{sub 3}O{sub 4}-Au/Ab1/AFP complex from the serum after incubation. The product can be separated from the background solution through the magnetic separation. Then the CdS-Au labeled secondary antibody (Ab2) as signal tag (CdS-Au/Ab2) was conjugated successfully with Fe{sub 3}O{sub 4}-Au/Ab1/AFP complex to form a sandwich-type immunocomplex (Fe{sub 3}O{sub 4}-Au/Ab1/AFP/Ab2/CdS-Au), which can be further separated by an external magnetic field and produce ECL signals at a fixed voltage. The signal was proportional to a certain concentration range of AFP for quantification. Thus, an easy-to-use immunosensor with magnetic probes and a quantum dots signal tag was obtained. The immunosensor performed at a level of high sensitivity and a broad concentration range for AFP between 0.0005 and 5.0 ng mL{sup -1} with a detection limit of 0.2 pg mL{sup -1}. The use of magnetic probes was combined with pre-concentration and separation for trace levels of tumor markers in the serum. Due to the

  15. Determination of neurotransmitters and their metabolites using one- and two-dimensional liquid chromatography with acidic potassium permanganate chemiluminescence detection.

    Science.gov (United States)

    Holland, Brendan J; Conlan, Xavier A; Stevenson, Paul G; Tye, Susannah; Reker, Ashlie; Barnett, Neil W; Adcock, Jacqui L; Francis, Paul S

    2014-09-01

    High-performance liquid chromatography with chemiluminescence detection based on the reaction with acidic potassium permanganate and formaldehyde was explored for the determination of neurotransmitters and their metabolites. The neurotransmitters norepinephrine and dopamine were quantified in the left and right hemispheres of rat hippocampus, nucleus accumbens and prefrontal cortex, and the metabolites vanillylmandelic acid, 3,4-dihydrophenylacetic acid, 5-hydroxyindole-3-acetic acid and homovanillic acid were identified in human urine. Under optimised chemiluminescence reagent conditions, the limits of detection for these analytes ranged from 2.5 × 10(-8) to 2.5 × 10(-7) M. For the determination of neurotransmitter metabolites in urine, a two-dimensional high-performance liquid chromatography (2D-HPLC) separation operated in heart-cutting mode was developed to overcome the peak capacity limitations of the one-dimensional separation. This approach provided the greater separation power of 2D-HPLC with analysis times comparable to conventional one-dimensional separations.

  16. Diagnosis of schistosomiasis japonica with interfacial co-assembly-based multi-channel electrochemical immunosensor arrays

    Science.gov (United States)

    Deng, Wangping; Xu, Bin; Hu, Haiyan; Li, Jianyong; Hu, Wei; Song, Shiping; Feng, Zheng; Fan, Chunhai

    2013-05-01

    Schistosomiasis control remains to be an important and challenging task in the world. However, lack of quick, simple, sensitive and specific sero-diagnostic test is still a hurdle in the control practice. The commonly employed enzyme-linked immuno-sorbent assay (ELISA) relies on the native soluble egg antigen (SEA) that is limited in supply. Here we developed an electrochemical immunosensor array (ECISA) assay with an interfacial co-assembly strategy. A recombinant Schistosoma japonicum (Sj) calcium-binding protein (SjE16) was used as a principal antigen, while the SEA as a minor, co-assembling agent, with a ratio of 8:1 (SjE16: SEA, Sj16EA), which was co-immobilized on a disposable 16-channel screen-printed carbon electrode array. A portable electrochemical detector was employed to detect antibodies in serum samples. The sensitivity of ECISA reached 100% with minimal cross-reactions. Therefore, we have demonstrated that this rapid, sensitive and specific ECISA technique has the potential to perform large-scale on-site screening of Sj infection.

  17. Determination of hydrogen peroxide in water by chemiluminescence detection, (1). Flow injection type hydrogen peroxide detection system

    International Nuclear Information System (INIS)

    Yamashiro, Naoya; Uchida, Shunsuke; Satoh, Yoshiyuki; Morishima, Yusuke; Yokoyama, Hiroaki; Satoh, Tomonori; Sugama, Junichi; Yamada, Rie

    2004-01-01

    A flow injection type hydrogen peroxide detection system with a sub-ppb detection limit has been developed to determine hydrogen peroxide concentration in water sampled from a high temperature, high pressure hydrogen peroxide water loop. The hydrogen peroxide detector is based on luminol chemiluminescence spectroscopy. A small amount of sample water (20 μl) is mixed with a reagent mixture, an aqueous solution of luminol and Co 2+ catalyst, in a mixing cell which is installed just upstream from the detection cell. The optimum values for pH and the concentrations of luminol and Co 2+ ion have been determined to ensure a lower detectable limit and a higher reproducibility. The photocurrent detected by the detection system is expressed by a linear function of the hydrogen peroxide concentration in the region of lower concentration ([H 2 O 2 ] 2 O 2 ] in the region of higher concentration ([H 2 O 2 ] > 10 ppb). The luminous intensity of luminol chemiluminescence is the highest when pH of the reagent mixture is 11.0. Optimization of the major parameters gives the lowest detectable limit of 0.3 ppb. (author)

  18. A High Sensitivity Micro Format Chemiluminescence Enzyme Inhibition Assay for Determination of Hg(II

    Directory of Open Access Journals (Sweden)

    Kanchanmala Deshpande

    2010-06-01

    Full Text Available A highly sensitive and specific enzyme inhibition assay based on alcohol oxidase (AlOx and horseradish peroxidase (HRP for determination of mercury Hg(II in water samples has been presented. This article describes the optimization and miniaturization of an enzymatic assay using a chemiluminescence reaction. The analytical performance and detection limit for determination of Hg(II was optimized in 96 well plates and further extended to 384 well plates with a 10-fold reduction in assay volume. Inhibition of the enzyme activity by dissolved Hg(II was found to be linear in the range 5–500 pg.mL−1 with 3% CVin inter-batch assay. Due to miniaturization of assay in 384 well plates, Hg(II was measurable as low as 1 pg.mL−1 within15 min. About 10-fold more specificity of the developed assay for Hg(II analysis was confirmed by challenging with interfering divalent metal ions such as cadmium Cd(II and lead Pb(II. Using the proposed assay we could successfully demonstrate that in a composite mixture of Hg(II, Cd(II and Pb(II, inhibition by each metal ion is significantly enhanced in the presence of the others. Applicability of the proposed assay for the determination of the Hg(II in spiked drinking and sea water resulted in recoveries ranging from 100–110.52%.

  19. Detection of pyrrolizidine alkaloids using flow analysis with both acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence

    International Nuclear Information System (INIS)

    Gorman, Bree A.; Barnett, Neil W.; Bos, Richard

    2005-01-01

    For the first time, analytically useful chemiluminescence was elicited from the reactions of the pyrrolizidine alkaloids. Heliotrine, retronecine, supinine, monocrotaline and echinatine N-oxide yielded chemiluminescence upon reaction with tris(2,2'-bipyridyl)ruthenium(II) whilst lasiocarpine, its N-oxide and supinine elicited light upon reaction with acidic potassium permanganate. Detection limits for heliotrine were 1.25 x 10 -7 M and 9 x 10 -9 M for tris(2,2'-bipyridyl)ruthenium(III) perchlorate with flow injection analysis (FIA) and the silica-immobilised reagent (4-[4-(dichloromethylsilanyl)-butyl]-4'-methyl-2,2'-bipyridine)bis (2,2'-bipyridyl)ruthenium(II) with sequential injection analysis (SIA), respectively. Lasiocarpine was detectable at 1.4 x 10 -7 M using acidic potassium permanganate with FIA. Additionally, the silica-immobilised reagent was optimised with respect to the oxidant (ammonium ceric nitrate) concentration and the aspiration times which afforded a detection limit for codeine of 5 x 10 -10 M using SIA

  20. Integrated luminometer for the determination of trace metals in seawater using fluorescence, phosphorescence and chemiluminescence detection

    OpenAIRE

    Worsfold, P. J.; Achterberg, E. P.; Bowie, A. R.; Cannizzaro, V.; Charles, S.; Costa, J. M.; Dubois, F.; Pereiro, R.; San Vicente, B.; Sanz-Medel, A.; Vandeloise, R.; Donckt, E. Vander; Wollast, P.; Yunus, S.

    2002-01-01

    The paper describes an integrated luminometer able to perform fluorescence (FL), room temperature phosphorescence (RTP) and chemiluminescence (CL) measurements on seawater samples. The technical details of the instrumentation are presented together with flow injection (FI) manifolds for the determination of cadmium and zinc (by FL), lead (RTP) and cobalt (CL). The analytical figures of merit are given for each mainfold and results are presented for the determination of the four trace metals i...

  1. Effect of Human and Bovine Serum Albumin on kinetic Chemiluminescence of Mn (III-Tetrakis (4-Sulfonatophenyl Porphyrin-Luminol-Hydrogen Peroxide System

    Directory of Open Access Journals (Sweden)

    Sayed Yahya Kazemi

    2012-01-01

    Full Text Available The present work deals with an attempt to study the effect of human and bovine serum albumin on kinetic parameters of chemiluminescence of luminol-hydrogen peroxide system catalyzed by manganese tetrasulfonatophenyl porphyrin (MnTSPP. The investigated parameters involved pseudo-first-order rise and fall rate constant for the chemiluminescence burst, maximum level intensity, time to reach maximum intensity, total light yield, and values of the intensity at maximum CL which were evaluated by nonlinear least square program KINFIT. Because of interaction of metalloporphyrin with proteins, the CL parameters are drastically affected. The systems resulted in Stern-Volmer plots with values of 3.17×105 and 3.7×105M−1 in the quencher concentration range of 1.5×10−6 to 1.5×10−5 M for human serum albumin (HSA and bovine serum albumin (BSA, respectively.

  2. Radiation-Induced Graft Polymerization of Vinyl Monomers with Anion Groups onto MWNT Supports and Their Application as Electrogenerated Chemiluminescence (ECL Biosensors

    Directory of Open Access Journals (Sweden)

    Ji-Hye Park

    2014-01-01

    Full Text Available Vinyl polymer-grafted multiwalled carbon nanotube (MWNT supports with anion groups were prepared for use as biosensor supports by radiation-induced graft polymerization (RIGP of the vinyl monomers acryloyl diphosphoric acid (ADPA, acrylic acid (AA, sodium styrenesulfonate (NaSS, and methacrylic acid (MA onto the surface of MWNTs. The electrogenerated chemiluminescence sensors based on a glass carbon electrode (ECL-GCE and a screen printed electrode (ECL-SPE were fabricated by immobilization of Ru(bpy3 2+ complex after coating of vinyl polymer-grafted MWNT inks on the surface of the GCE and SPE without any polymer binders in order to obtain high electrogenerated chemiluminescence intensity. For detection of alcohol concentration, alcohol dehydrogenase (ADH was immobilized onto an ECL-GCE sensor prepared by poly(NaSS-g-MWNT supports. The prepared biosensor based on ADH is suitable for the detection of ethanol concentration in commercial drinks.

  3. Development and validation of a direct sandwich chemiluminescence immunoassay for measuring DNA adducts of benzo[a]pyrene and other polycyclic aromatic hydrocarbons

    DEFF Research Database (Denmark)

    Georgiadis, Panagiotis; Kovács, Katalin; Kaila, Stella

    2012-01-01

    We have developed and validated a sandwich chemiluminescence immunoassay (SCIA) which measures polycyclic aromatic hydrocarbon (PAH)-DNA adducts combining high throughput and adequate sensitivity, appropriate for evaluation of adduct levels in human population studies. Fragmented DNA is incubated...

  4. The determination of psilocin and psilocybin in hallucinogenic mushrooms by HPLC utilizing a dual reagent acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection system.

    Science.gov (United States)

    Anastos, Nicole; Lewis, Simon W; Barnett, Neil W; Sims, D Noel

    2006-01-01

    This paper describes a procedure for the determination of psilocin and psilocybin in mushroom extracts using high-performance liquid chromatography with postcolumn chemiluminescence detection. A number of extraction methods for psilocin and psilocybin in hallucinogenic mushrooms were investigated, with a simple methanolic extraction being found to be most effective. Psilocin and psilocybin were extracted from a variety of hallucinogenic mushrooms using methanol. The analytes were separated on a C12 column using a (95:5% v/v) methanol:10 mM ammonium formate, pH 3.5 mobile phase with a run time of 5 min. Detection was realized through a dual reagent chemiluminescence detection system of acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II). The chemiluminescence detection system gave improved detectability when compared with UV absorption at 269 nm, with detection limits of 1.2 x 10(-8) and 3.5 x 10(-9) mol/L being obtained for psilocin and psilocybin, respectively. The procedure was applied to the determination of psilocin and psilocybin in three Australian species of hallucinogenic mushroom.

  5. Chemiluminescence behavior of the carbon dots and the reduced state carbon dots

    Energy Technology Data Exchange (ETDEWEB)

    Teng, Ping [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Xie, Jianxin [College of Resources and Environment, Yuxi Normal University, Yuxi, Yunnan 653100 (China); Long, Yijuan; Huang, Xiaoxiao; Zhu, Rui; Wang, Xiliang; Liang, Liping [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Huang, Yuming, E-mail: ymhuang@swu.edu.cn [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Zheng, Huzhi, E-mail: zhenghz@swu.edu.cn [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China)

    2014-02-15

    Potassium permanganate (KMnO{sub 4}) can react with two different carbon nanoparticles, i.e., carbon dots (CDs) and reduced state carbon dots (r-CDs), in a strong acid medium to generate chemiluminescence (CL). Furthermore, the different CL intensities and CL behaviors due to the different surface groups on these two kinds of carbon nanoparticles were confirmed. CL spectra, fluorescence spectra, UV–vis absorption spectra, and electron paramagnanetic resonance spectra were applied to investigate the CL mechanism. The main reaction pathways were proposed as follows: for the CL reaction between CDs and KMnO{sub 4}, the excited states of CDs (CDs{sup ⁎}) and Mn(II) (Mn(II){sup ⁎}) emerged as KMnO{sub 4} could inject holes into CDs, then, the CDs{sup ⁎} and Mn(II){sup ⁎} acted as luminophors to yield CL; in the r-CDs-KMnO{sub 4} system, r-CDs were oxidized by KMnO{sub 4} directly, and CDs{sup ⁎} and Mn(II){sup ⁎} were produced, at the same time, CL occurred. What is more interesting is that the CL intensity of the r-CD system is stronger than that of the CD system, which confirms that functional groups have strong effect on the CL behavior. It inspired us that new carbon nanoparticles with excellent luminous performance can be designed by tuning their surface groups. -- Highlights: • Carbon dots (CDs) and reduced state carbon dots (r-CDs) can react with potassium permanganate (KMnO{sub 4}) in a strong acid to generate chemiluminescence (CL). • With different surface groups, the CL intensity of r-CDs-KMnO{sub 4} system is different from that of CDs-KMnO{sub 4} system. • The CL mechanisms of the two systems were investigated.

  6. Voltammetric immunosensor for human chorionic gonadotropin using a glassy carbon electrode modified with silver nanoparticles and a nanocomposite composed of graphene, chitosan and ionic liquid, and using riboflavin as a redox probe

    International Nuclear Information System (INIS)

    Roushani, Mahmoud; Valipour, Akram

    2016-01-01

    The aim of this study was to develop an electrochemical immunoassay system to detect of human chorionic gonadotropin (hCG). The immunosensor was constructed by covalent immobilization of silver nanoparticles (AgNPs) onto a nanocomposite containing graphene, chitosan (Chit) and 1-methyl-3-octylimidazolium tetrafluoroborate as ionic liquid (IL). Silver nanoparticles were used as a linker to immobilize hCG antibody onto the modified electrode. The amino groups of the antibody were covalently attached to an AgNP/g-IL-Chit nanocomposite. Cyclic voltammetry and electrochemical impedance spectroscopy were employed to characterize the assembly process of the immunosensor. Riboflavin was used as the redox probe. Differential pulse voltammetry demonstrated that the formation of antibody–antigen complexes decreases the peak current of redox pair at the AgNP/Gr-IL-Chit/GCE (at a working potential of −0.38 V). The signal changes of riboflavin are used to detect hCG with broad response ranges from 0.0212 to 530 mIU.mL −1 and a low detection limit of 0.0066 ± 0.02 mIU.mL −1 . (author)

  7. Neutrophil Leukocyte: Combustive Microbicidal Action and Chemiluminescence

    Directory of Open Access Journals (Sweden)

    Robert C. Allen

    2015-01-01

    Full Text Available Neutrophil leukocytes protect against a varied and complex array of microbes by providing microbicidal action that is simple, potent, and focused. Neutrophils provide such action via redox reactions that change the frontier orbitals of oxygen (O2 facilitating combustion. The spin conservation rules define the symmetry barrier that prevents direct reaction of diradical O2 with nonradical molecules, explaining why combustion is not spontaneous. In burning, the spin barrier is overcome when energy causes homolytic bond cleavage producing radicals capable of reacting with diradical O2 to yield oxygenated radical products that further participate in reactive propagation. Neutrophil mediated combustion is by a different pathway. Changing the spin quantum state of O2 removes the symmetry restriction to reaction. Electronically excited singlet molecular oxygen (O2*1 is a potent electrophilic reactant with a finite lifetime that restricts its radius of reactivity and focuses combustive action on the target microbe. The resulting exergonic dioxygenation reactions produce electronically excited carbonyls that relax by light emission, that is, chemiluminescence. This overview of neutrophil combustive microbicidal action takes the perspectives of spin conservation and bosonic-fermionic frontier orbital considerations. The necessary principles of particle physics and quantum mechanics are developed and integrated into a fundamental explanation of neutrophil microbicidal metabolism.

  8. pH responsive label-assisted click chemistry triggered sensitivity amplification for ultrasensitive electrochemical detection of carbohydrate antigen 24-2.

    Science.gov (United States)

    Zheng, Yun; Zhao, Lihua; Ma, Zhanfang

    2018-05-15

    Sensitivity amplification strategy by implementing click chemistry in the construction of biosensing interface can efficiently improve the performance of immunosensor. Herein, we developed a sandwich-type amperometric immunosensor for ultrasensitive detection of carbohydrate antigen 24-2 (CA 242) based on pH responsive label-assisted click chemistry triggered sensitivity amplification strategy. The sensitivity of amperometric immunosensor relies on the current response differences (ΔI) caused by per unit concentration target analyte. The pH responsive Cu 2+ -loaded polydopamine (CuPDA) particles conjugated with detection antibodies were employed as labels, which can release Cu(II) ions by regulating pH. In the presence of ascorbic acid (reductant), Cu(II) ions were reduced to Cu(I) ions. Azide-functionalized double-stranded DNA (dsDNA) as signal enhancer was immobilized on the substrate through Cu + -catalyzed azide/alkyne cycloaddition reaction. With the help of the click reaction, the ΔI caused by target was elevated prominently, resulting in sensitivity amplification of the immunosensor. Under optimal condition, the proposed immunosensor exhibited excellent performance with linear range from 0.0001 to 100 U mL -1 and ultralow detection limit of 20.74 μU mL -1 . This work successfully combines click chemistry with pH-responsive labels in sandwich-type amperometric immunosensor, providing a promising sensitivity amplification strategy to construct immunosensing platform for analysis of other tumor marker. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Evaluation of silicon-chemiluminescence monitoring as a novel method for atomic fluorine determination and end point detection in plasma etch systems

    NARCIS (Netherlands)

    Zijlstra, P.A.; Beenakker, C.I.M.

    1981-01-01

    Optical methods for the detection of atomic fluorine in plasma etch systems are discussed and an experimental comparison is made between detection by optical emission and by a novel method based on the chemiluminescence from solid silicon in the presence of atomic fluorine. Although both methods

  10. Prussian blue-gold nanoparticles-ionic liquid functionalized reduced graphene oxide nanocomposite as label for ultrasensitive electrochemical immunoassay of alpha-fetoprotein.

    Science.gov (United States)

    Gao, Qi; Liu, Na; Ma, Zhanfang

    2014-06-04

    In this work, poly(diallyldimethylammonium chloride) (PDDA) protected Prussian blue/gold nanoparticles/ionic liquid functionalized reduced graphene oxide (IL-rGO-Au-PDDA-PB) nanocomposite was fabricated. The resulting nanocomposite exhibited high biocompatibility, conductivity and catalytic activity. To assess the performance of the nanocomposite, a sensitive sandwich-type immunosensor was constructed for detecting alpha-fetoprotein (AFP). Greatly enhanced sensitivity for this immunosensor was based on triple signal amplification strategies. Firstly, IL-rGO modified electrode was used as biosensor platform to capture a large amount of antibody due to its increased surface area, thus amplifying the detection response. Secondly, a large number of Au-PDDA-PB was conjugated on the surface of IL-rGO, which meant the enrichment of the signal and the more immobilization of label antibody. Finally, the catalytic reaction between H2O2 and the IL-rGO-Au-PDDA-PB nanocomposite further enhanced the signal response. The signals increased linearly with AFP concentrations in the range of 0.01-100 ng mL(-1). The detection limit for AFP was 4.6 pg mL(-1). The immunosensor showed high sensitivity, excellent selectivity and good stability. Moreover, the immunosensor was applied to the analysis of AFP in serum sample with satisfactory result. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Determination of ethanol using permanganate-CdS quantum dot chemiluminescence system.

    Science.gov (United States)

    Abolhasani, Jafar; Hassanzadeh, Javad

    2015-08-01

    A novel and highly sensitive chemiluminescence (CL) method for the determination of ethanol was developed based on the CdS quantum dots (QDs)-permanganate system. It was found that KMnO4 could directly oxidize CdS QDs in acidic media resulting in relatively high CL emission. A possible mechanism was proposed for this reaction based on UV/Vis absorption, fluorescence and the generated CL emission spectra. However, it was observed that ethanol had a remarkable inhibition effect on this system. This effect was exploited in the determination of ethanol within the concentration range 12-300 µg/L, with detection at 4.3 µg/L. In order to evaluate the capability of presented method, it was satisfactorily utilized in the determination of alcohol in real samples. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Fiber-Optic Chemiluminescent Biosensors for Monitoring Aqueous Alcohols and Other Water Quality Parameters

    Science.gov (United States)

    Verostko, Charles E. (Inventor); Atwater, James E. (Inventor); Akse, James R. (Inventor); DeHart, Jeffrey L. (Inventor); Wheeler, Richard R. (Inventor)

    1998-01-01

    A "reagentless" chemiluminescent biosensor and method for the determination of hydrogen peroxide, ethanol and D-glucose in water is disclosed. An aqueous stream is basified by passing it through a solid phase base bed. Luminol is then dissolved in the basified effluent at a controlled rate. Oxidation of the luminol is catalyzed by the target chemical to produce emitted light. The intensity of the emitted light is detected as a measure of the target chemical concentration in the aqueous stream. The emitted light can be transmitted by a fiber optic bundle to a remote location from the aqueous stream for a remote reading of the target chemical concentration.

  13. Detection of pyrrolizidine alkaloids using flow analysis with both acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Gorman, Bree A. [School of Biological and Chemical Sciences, Deakin University, Geelong, Vic. 3217 (Australia); Barnett, Neil W. [School of Biological and Chemical Sciences, Deakin University, Geelong, Vic. 3217 (Australia)]. E-mail: barnie@deakin.edu.au; Bos, Richard [School of Biological and Chemical Sciences, Deakin University, Geelong, Vic. 3217 (Australia)

    2005-06-13

    For the first time, analytically useful chemiluminescence was elicited from the reactions of the pyrrolizidine alkaloids. Heliotrine, retronecine, supinine, monocrotaline and echinatine N-oxide yielded chemiluminescence upon reaction with tris(2,2'-bipyridyl)ruthenium(II) whilst lasiocarpine, its N-oxide and supinine elicited light upon reaction with acidic potassium permanganate. Detection limits for heliotrine were 1.25 x 10{sup -7} M and 9 x 10{sup -9} M for tris(2,2'-bipyridyl)ruthenium(III) perchlorate with flow injection analysis (FIA) and the silica-immobilised reagent (4-[4-(dichloromethylsilanyl)-butyl]-4'-methyl-2,2'-bipyridine)bis (2,2'-bipyridyl)ruthenium(II) with sequential injection analysis (SIA), respectively. Lasiocarpine was detectable at 1.4 x 10{sup -7} M using acidic potassium permanganate with FIA. Additionally, the silica-immobilised reagent was optimised with respect to the oxidant (ammonium ceric nitrate) concentration and the aspiration times which afforded a detection limit for codeine of 5 x 10{sup -10} M using SIA.

  14. Chemiluminescence-based multivariate sensing of local equivalence ratios in premixed atmospheric methane-air flames

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, Markandey M.; Krishnan, Sundar R.; Srinivasan, Kalyan K.; Yueh, Fang-Yu; Singh, Jagdish P.

    2011-09-07

    Chemiluminescence emissions from OH*, CH*, C2, and CO2 formed within the reaction zone of premixed flames depend upon the fuel-air equivalence ratio in the burning mixture. In the present paper, a new partial least square regression (PLS-R) based multivariate sensing methodology is investigated and compared with an OH*/CH* intensity ratio-based calibration model for sensing equivalence ratio in atmospheric methane-air premixed flames. Five replications of spectral data at nine different equivalence ratios ranging from 0.73 to 1.48 were used in the calibration of both models. During model development, the PLS-R model was initially validated with the calibration data set using the leave-one-out cross validation technique. Since the PLS-R model used the entire raw spectral intensities, it did not need the nonlinear background subtraction of CO2 emission that is required for typical OH*/CH* intensity ratio calibrations. An unbiased spectral data set (not used in the PLS-R model development), for 28 different equivalence ratio conditions ranging from 0.71 to 1.67, was used to predict equivalence ratios using the PLS-R and the intensity ratio calibration models. It was found that the equivalence ratios predicted with the PLS-R based multivariate calibration model matched the experimentally measured equivalence ratios within 7%; whereas, the OH*/CH* intensity ratio calibration grossly underpredicted equivalence ratios in comparison to measured equivalence ratios, especially under rich conditions ( > 1.2). The practical implications of the chemiluminescence-based multivariate equivalence ratio sensing methodology are also discussed.

  15. Suitability of thermoluminescence, chemiluminescence, ESR and viscosity measurements as detection method for the irradiation of medicinal herbs

    International Nuclear Information System (INIS)

    Schuettler, C.; Gebhardt, G.; Stock, A.; Helle, N.; Boegl, K.W.

    1993-01-01

    Chemiluminescence, electron spin resonance, thermoluminescence and viscosity measurements have been investigated for their suitability as detection method for the irradiation of the medicinal herbs anise seeds (anisi fructus), valerian roots (valerianae radix), redberry leaves (uvae ursi folium), birch leaves (betulae folium), greek hay seeds (foenugraeci semen), cayenne pepper (capsici fructus acer), black-aldertee bark (frangulae cortex), fennel fruits (feoniculi fructus), rose hip shells (cynosbati fructus), coltsfoot (farfarae folium), acorus roots (calami rhizoma), chamomile flowers (matricariae flos), caraway (carvi fructus), lavender flowers (lavandulae flos), linseed (lini semen), lime tree flowers (tiliae flos), St. Mary's thistle fruit (cardui mariae herba), lemon balm (melissae folium), java tea (orthosiphonis folium), peppermint (menthae piperitae folium), sage leaves (salviae folium), scouring rush (equiseti herba), senna leaves (sennae folium), plantain herbs (plantaginis lanceolata herba), thyme herbs (thymi herba), juniper berries (juniperi fructus), hawthorne herbs (crataegi folium), wheat starch (amylum tritici) and wormwood (absinthii herba). Depending on the herbs, the methods used were more or less suitable. Chemiluminescence measurements showed the smallest differences between untreated and irradiated samples whereas thermoluminescence measurements on isolated minerals from the vegetable drugs gave better results. In some herbs radiation-specific radicals could be identified by ESR spectroscopy. Viscosity measurement is suitable for some herbs as fast and inexpensive method for screening. (orig.) [de

  16. Development of an enrofloxacin immunosensor based on label-free electrochemical impedance spectroscopy.

    Science.gov (United States)

    Wu, Ching-Chou; Lin, Chia-Hung; Wang, Way-Shyan

    2009-06-30

    Enrofloxacin is the most widespread antibiotic in the fluoroquinolone family. As such, the development of a rapid and sensitive method for the determination of trace amounts of enrofloxacin is an important issue in the health field. The interaction of the enrofloxacin antigen to a specific antibody (Ab) immobilized on an 11-mercapto-undecanoic acid-coated gold electrode was quantified by electrochemical impedance spectroscopy. Two equivalent circuits were separately used to interpret the obtained impedance spectra. These circuits included one resistor in series with one parallel circuit comprised of a resistor and a capacitor (1R//C), and one resistor in series with two parallel RC circuits (2R//C). The results indicate that the antigen-antibody reaction analyzed using the 1R//C circuit provided a more sensitive resistance increment against the enrofloxacin concentration than that of the 2R//C circuit. However, the 2R//C circuit provided a better fitting for impedance spectra, and therefore supplies more detailed results of the enrofloxacin-antibody interaction, causing the increase of electron transfer resistance selectively to the modified layer, and not the electrical double layer. The antibody-modified electrode allowed for analysis of the dynamic linear range of 1-1000 ng/ml enrofloxacin with a detection limit of 1 ng/ml. The reagentless and label-free impedimetric immunosensors provide a simple and sensitive detection method for the specific determination of enrofloxacin.

  17. Analytical Application of Flow Immunosensor in Detection of Thyroxine and Triiodothyronine in Serum.

    Science.gov (United States)

    Wani, Tanveer A; Zargar, Seema; Majid, Salma; Darwish, Ibrahim A

    2016-11-01

    In this study, an immunosensor based on kinetic exclusion analysis (KinExA) was used for thyroxine (T4) and triiodothyronine (T3) estimation. A KinExA™ 3200 instrument was used for this analysis, which is an automated flow fluorimeter designed to separate free unbound antibody binding sites in reaction mixtures of antibody, antigen, and antibody-antigen complex. A T3-BSA- and T4-BSA-coated polymethyl methacrylate (PMMA) bead microcolumn is generated inside the flow cell of the instrument. A sample mixture containing T3 and T4 with their respective monoclonal antibodies and their complexes are drawn past the microbead column. The unbound T3 or T4 monoclonal antibody binding sites are captured by their respective T3 and T4 antigens coated on the PMMA beads as bovine serum albumin conjugates. Fluorescently labeled secondary antibodies bind to the T3 or T4 antigen-antibody complex to generate fluorescence intensity for analysis. The limit of detection for the T3 and T4 assays was found to be 0.06 and 1.9 ng mL -1 with acceptable precision values. The convenience of the automated KinExA format may be valuable in medical diagnostic laboratories.

  18. Can irradiation of spices be detected by chemiluminescence?

    International Nuclear Information System (INIS)

    Delincee, H.

    1987-01-01

    Chemiluminescence (CL) has been reported as a reliable identification measure for radiation processed spices. Luminescence intensities, however, vary considerably from one spice to another. Even for one spice from various producers, different results have been obtained. One of the main drawbacks of CL is its poor reproducibility. Attempts to reduce the variability have so far been unsuccessful. Since the CL response is frequently a non-monotone function of dose, the applied radiation dose cannot be estimated unequivocally. Attempts to establish an internal standard were not successful. A further hindrance for dose estimation is the fading of luminescence with storage time. In the case of juniper berries 50-78% of the irradiated samples could be identified correctly, depending on selection criteria. With marjoram, however, only one out of five samples could be identified. Variations in the radiation conditions did not change CL. However, an increase in CL was also noted in some experiments with fumigated spices. The CL measurement as a single tool for identifying radiation processed spices seems at the moment not to fulfil the requirements of reliable detection. A combination of methods may eventually allow identification of irradiated spices. (orig./MG) [de

  19. Can irradiation of spices be detected by chemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Delincee, H

    1987-01-01

    Chemiluminescence (CL) has been reported as a reliable identification measure for radiation processed spices. Luminescence intensities, however, vary considerably from one spice to another. Even for one spice from various producers, different results have been obtained. One of the main drawbacks of CL is its poor reproducibility. Attempts to reduce the variability have so far been unsuccessful. Since the CL response is frequently a non-monotone function of dose, the applied radiation dose cannot be estimated unequivocally. Attempts to establish an internal standard were not successful. A further hindrance for dose estimation is the fading of luminescence with storage time. In the case of juniper berries 50-78% of the irradiated samples could be identified correctly, depending on selection criteria. With marjoram, however, only one out of five samples could be identified. Variations in the radiation conditions did not change CL. However, an increase in CL was also noted in some experiments with fumigated spices. The CL measurement as a single tool for identifying radiation processed spices seems at the moment not to fulfil the requirements of reliable detection. A combination of methods may eventually allow identification of irradiated spices.

  20. Sequential Injection Determination of D-Glucose by Chemiluminescence Using an Open Tubular Immobilised Enzyme Reactor

    DEFF Research Database (Denmark)

    Liu, Xuezhu; Hansen, Elo Harald

    1996-01-01

    A sequential injection analysis system is described that incorporates a nylon tubular reactor containing immobilised glucose oxidase, allowing determination of D-glucose by means of subsequent luminol chemiluminescence detection of the hydrogen peroxide generated in the enzymatic reaction....... The operating parameters were optimised by fractional factorial screening and response surface modelling. The linear range of D-glucose determination was 30-600 mu M, With a detection limit of 15 mu M using a photodiode detector. The sampling frequency was 54 h(-1). Lower LOD (0.5 mu M D-glucose) could...

  1. Piezoelectric immunosensors for the detection of individual antibiotics and the total content of penicillin antibiotics in foodstuffs.

    Science.gov (United States)

    Karaseva, N A; Ermolaeva, T N

    2014-03-01

    Piezoelectric immunosensors on the basis of homologous and group-specificantibodies have been developed for detecting penicillin G, ampicillin, and the total content of penicillin antibiotics. The receptor coating of the sensor was obtained by the immobilization of penicillin G or ampicillin hapten-protein conjugates on the polypyrrole film obtained by electropolymerization and activated by glutaraldehyde. The affinity constants and the cross reactivity coefficients have been calculated. This made it possible to estimate the affinity and specificity of the polyclonal and monoclonal antibodies used. The calibration curves are linear in the range of concentrations 2.5-250.0 ng ml(-1) (penicillin G), 2.5-500.0 ng ml(-1) (ampicillin), and 1-500 ng ml(-1) (group of penicillin). The limits of detection are 0.8 ng ml(-1), 3.9 ng ml(-1), which are lower than MRL, established for penicillin antibiotics. The sensors were tested in detecting penicillins in milk, pork, beef, liver. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Dual-readout Immunochromatographic Assay by Utilizing MnO2 Nanoflowers as the Unique Colorimetric/Chemiluminescent Probe

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Hui; Lu, Quian; Wang, Wenwen; Song, Yang; Tu, Xinman; Zhu, Chengzhou; Smith, Jordan N.; Du, Dan; Fu, Zhifeng; Lin, Yuehe

    2018-04-17

    Manganese dioxide nanoflowers (MnO2 NFs) were synthesized and utilized as a dual readout probe to develop a novel immunochromatographic test strip (ITS) for detecting pesticide residues using chlorpyrifos as the model analyte. MnO2 NFs-labeled antibody for chlorpyrifos was employed as the signal tracer for conducting the ITS. After 10-min competitive immunoreaction, the tracer antibody was captured by the immobilized immunogen on test line in the test strip, resulting in the accumulation of MnO2 NFs. The accumulation of MnO2 NFs led to the appearance of brown color on the test line, which could be easily observed by the naked eye as a qualitative readout. Moreover, MnO2 NFs showed a remarkably enhancing effect on the luminol-H2O2 chemiluminescent (CL) system. Unlike peroxidase-like nanomaterials, the enhancing mechanism of MnO2 NFs was based on its oxidant activity to decompose H2O2 for forming reactive oxygen species. After initiating the CL system in the test zone, strong CL signal was collected as a quantitative readout to sensitively detect chlorpyrifos. Under optimal conditions, the linear range of chlorpyrifos was 0.1–50 ng/mL with a low detection limit of 0.033 ng/mL (S/N = 3). The reliability of the dual-readout ITS was successfully demonstrated by the application on traditional Chinese medicine and environmental water samples. Due to the simultaneous rapid-qualitative and sensitive-quantitative detection, the dual-readout protocol provides a promising strategy for rapid screening and field assay on various areas such as environmental monitoring, food safety and point-of-care testing.

  3. A sensitive and selective chemiluminescence sensor for the determination of dopamine based on silanized magnetic graphene oxide-molecularly imprinted polymer.

    Science.gov (United States)

    Duan, Huimin; Li, Leilei; Wang, Xiaojiao; Wang, Yanhui; Li, Jianbo; Luo, Chuannan

    2015-03-15

    Based on silanized magnetic graphene oxide-molecularly imprinted polymer (Si-MG-MIP), a sensitive and selective chemiluminescence sensor for dopamine measurement was developed. Si-MG-MIP, in which silanes was introduced to improve the mass transfer, graphene oxide was employed to improve absorption capacity, Fe3O4 nanoparticles were applied for separation easily and molecularly imprinted polymer was used to improve selectivity, demonstrated the advantages of the sensor. All the composites were confirmed by SEM, TEM, XRD and FTIR. Under the optimal conditions of chemiluminescence, dopamine could be assayed in the range of 8.0-200.0 ng/mL with a correlation coefficient of linear regression of 0.9970. The detection limit was 1.5 ng/mL (3δ) and the precision for 11 replicate detections of 80.0 ng/mL dopamine was 3.4% (RSD). When the sensor was applied in determining dopamine in actual samples, recovery ranged from 94% to 110%, which revealed that the results were satisfactory. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. A novel chemiluminescence system with diperiodatonickelate (IV) for the determination of adrenaline

    Science.gov (United States)

    Yang, Chunyan; Chen, Fubin; Chang, Ziqiang; Sun, Yonghua; Zhang, Zhujun

    2014-03-01

    A novel chemiluminescence (CL) system with diperiodatonickelate (IV) (DPN) was developed for the determination of adrenaline for the first time. The possible CL emission mechanism was briefly discussed by comparing the fluorescence emission spectra with CL spectra. Under the optimum conditions, the relative CL intensity was linear over the concentration of AD ranging from 1.0 × 10-7 to 1.0 × 10-5 g mL-1 with a detection limit of 4.0 × 10-8 g mL-1 (3σ). And the relative standard deviation was 3.7% for 2.0 × 10-6 g mL-1 AD (n = 11). The developed method has been successfully applied to the determination of AD in pharmaceutical preparations.

  5. Chemiluminescence determination of streptomycin in pharmaceutical preparation and its application to pharmacokinetic study by a flow injection analysis assembly

    Science.gov (United States)

    Du, Bin; Li, Hongyan; Jin, Jianwen; Wang, Tiantian; Li, Yang; Shen, Guopeng; Li, Xiaotian

    2013-11-01

    A novel and rapid method for the determination of streptomycin has been established by chemiluminescence (CL) based on significant intensity enhancement of streptomycin on the weak CL of N-bromosuccinimide (NBS) and eosin in alkaline medium. The method is simple, rapid and effective to determine streptomycin in the range of 8.0 × 10-9-1.0 × 10-6 g mL-1 with a determination limit of 2.25 × 10-9 g mL-1. The relative standard deviation is 1.95% for the determination of 2.0 × 10-7 g mL-1 streptomycin (n = 11). The pharmacokinetics of streptomycin in plasma of rat coincides with the two-compartment open model. The T1/2α, T1/2β, CL/F, AUC(0-t), MRT, Tmax and Cmax were 18.83 ± 1.24 min, 82.14 ± 3.07 min, 0.0026 ± 0.0011 L kg-1 min-1, 36044.50 ± 105.02 mg min-1 L-1, 92.29 ± 8.21 min, 21.63 ± 1.26 min and 375.61 ± 8.50 μg mL-1, respectively. There was no significant difference between the results obtained by CL and HPLC. The FI-CL method can be used to determine streptomycin in pharmaceutical preparation and biological samples. The established method is simple, rapid and sensitive without expensive instruments. The possible enhancement mechanism was also investigated.

  6. Encapsulation of Hemin in Metal-Organic Frameworks for Catalyzing the Chemiluminescence Reaction of the H2O2-Luminol System and Detecting Glucose in the Neutral Condition.

    Science.gov (United States)

    Luo, Fenqiang; Lin, Yaolin; Zheng, Liyan; Lin, Xiaomei; Chi, Yuwu

    2015-06-03

    Novel metal-organic frameworks (MOFs) based solid catalysts have been synthesized by encapsulating Hemin into the HKUST-1 MOF materials. These have been first applied in the chemiluminescence field with outstanding performance. The functionalized MOFs not only maintain an excellent catalytic activity inheriting from Hemin but also can be cyclically utilized as solid mimic peroxidases in the neutral condition. The synthesized Hemin@HKUST-1 composites have been used to develop practical sensors for H2O2 and glucose with wide response ranges and low detection limits. It was envisioned that catalyst-functionalized MOFs for chemiluminescence sensing would have promising applications in green, selective, and sensitive detection of target analytes in the future.

  7. Adaptation of a load-inject valve for a flow injection chemiluminescence system enabling dual-reagent injection enhances understanding of environmental Fenton chemistry

    International Nuclear Information System (INIS)

    Jones, Matthew R.; Nightingale, Philp D.; Turner, Suzanne M.; Liss, Peter S.

    2013-01-01

    Graphical abstract: -- Highlights: •Measurement of multiple components of Fenton chemistry; Fe(II) and H 2 O 2 . •Rapid, quasi-simultaneous analysis enables calculation of environmental kinetics. •Low, nano to pico-molar detection limits with dual analyte analysis. •Able to measure complex matrix samples – organically enriched seawater. •Low cost system with appreciable sensitivity compared to single analyte analysis. -- Abstract: Environmental Fenton chemistry has been poorly constrained within the marine environment at a multi-component level. A simple, unique, reconfiguration of a flow-injection analytical system combined with luminol chemiluminescence allows quasi-simultaneously the measurement, using a single load-inject valve and a single photon multiplier tube, of reduced iron, Fe(II), and hydrogen peroxide. The system enables rapid, every 22 s, measurements with good accuracy at environmentally relevant concentrations, less than 5% relative standard deviations on both a 5 nM Fe(II) standard and a 60 nM hydrogen peroxide standard. Limits of detection were as low as 40 pM Fe(II) and 100 pM hydrogen peroxide. The system showed excellent capability by measuring from within an organic rich seawater the photochemically induced production of Fe(II) and hydrogen peroxide and their subsequent cycling and Fenton like interactions

  8. Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system

    Directory of Open Access Journals (Sweden)

    Li-Juan Wang

    2011-02-01

    Full Text Available A novel flow injection chemiluminescence (CL method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4, and Na2SO3 in acid media. The CL intensity of KMnO4-Na2SO3 was greatly enhaneed in the presence of loxoprofen and naproxen. The mechanism of the CL reaction was studied by the kinetic proecss and UV-vis absorption and the conditions were optimized. Under optimized conditions, the CL intensity was linear with loxoprofen and naproxen concentration in the range of 7.0 × 10−8 – 1.0 × 10−5 g/mL and 2.0 × 10−7 – 4.0 × 10−6 g/mL with the detection limit of 2.0 × 10−8 g/mL and 3.0 × 10−8 g/mL (S/N = 3, respectively. Thc relative standard deviations were 2.39% and 1.37% for 5.0 × 10−7 g/mL naproxen and 5.0 × 10−7 g/mL loxoprofen (n = 10, respectively. The proposed method was satisfactorily applied to thc determination of loxoprofen and naproxen in pharmaceutical preparations. Keywords: chemiluminescence, KMnO4, loxoprofen, naproxen

  9. Development of nanobody-based flow injection chemiluminescence immunoassay for sensitive detection of human prealbumin.

    Science.gov (United States)

    Ma, Lei; Sun, Yanyan; Kang, Xuejun; Wan, Yakun

    2014-11-15

    Nanobodies, derived from camelid heavy-chain antibodies, have novel and impactful applications in clinical diagnostics. Our objective is to develop a nanobody-based chemiluminescence immunoassay for sensitive detection of human prealbumin (PA). In this context, a phage display nanobody library is constructed via immunizing dromedary camel with human prealbumin. Three nanobodies have been identified by five successive bio-panning steps. Based on their high expression level and good affinity, two out of three are chosen for further study. Magnetic beads (MBs) were functionalized with PEI by acylamide bond formed between the carboxyl group on the surface of the MB. Then, an anti-PA nanobody (Nb1) can be effectively immobilized onto the surface of the functionalized MB using glutaradehyde as the link. The modified MBs with Nb1 can specifically capture the target PA and reacted with silica nanoparticles with co-immobilized HRP and anti-PA nanobody (Nb2). The concentration of PA was detected by flow injection chemiluminescence. When using MB/PEI as the carrier of anti-PA Nb1, the CL signal significantly increased to 4-fold compared with the signal using MB without PEI modification. The CL signal was further amplified to 5-fold when Si/Nb2 was used as the signal probe. Under optimized conditions, the present immunoassay exhibited a wide quantitative range from 0.05 to 1000 μg L(-1) with a detection limit of 0.01 μg L(-1). The sensitivity of the proposed immunoassay offers great promises in providing a sensitive, specific, time saving, and potential method for detecting PA in clinical settings. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Application of Box-Behnken design in the optimization of catalytic behavior of a new mixed chelate of copper (II) complex in chemiluminescence reaction of luminol

    International Nuclear Information System (INIS)

    Khajvand, Tahereh; Chaichi, Mohammad Javad; Nazari, OmLeila; Golchoubian, Hamid

    2011-01-01

    In this work, we observed an enhancement of chemiluminescence (CL) emission of luminol when a new mixed chelate of copper complex (N-(2-(2-aminoethylamino)ethyl)-1H-pyrrole-2-carboxamide-Cu(II)) was mixed with a solution containing luminol in methanol/water. The Box-Behnken design matrix and response surface methodology (RSM) have been applied to design the experiments to evaluate the interactive effects of the three most important operating variables-luminol (10 -4 -10 -2 M), fluorescein (10 -5 -10 -3 M) and hydrogen peroxide (1-3 M) concentrations on the CL emission of luminol. The total 15 experiments were conducted in the present study towards the construction of a quadratic model. Independent variables luminol and hydrogen peroxide have significant value P F less than 0.0500 indicate that model terms are significant for the CL emission of luminol. The regression equation coefficients were calculated and the data fitted to a second-order polynomial equation for CL emission of luminol. The new introduced inorganic catalyst of luminol CL reaction can be effect more than that of the common ones such as potassium hexacyanoferrate (III) and copper (II) acetate. - Research highlights: → In this study we introduce a new mixed chelate of copper complex as a catalyst of luminol chemiluminescence (CL) reaction. → The copper complex (N-(2-(2-aminoethylamino)ethyl)-1H-pyrrole-2-carboxamide-Cu(II)) catalyst luminol reaction more than that of copper acetate and potassium hexacyanoferrate (III). → The Box-Behnken design matrix and response surface methodology are used for prediction of CL intensity of luminol. → There are good correlation between experimental and expected CL intensity that predicted by the theoretical model. → Fluorescein used as a fluorescer in the luminol CL reaction in presence of the new catalyst.

  11. Nanopolyaniline as immobilization template for signal enhancement of surface plasmon resonance biosensor - A preliminary study

    Science.gov (United States)

    Kamarun, Dzaraini; Abdul Azem, Nor Hazirah Kamel; Sarijo, Siti Halimah; Mohd, Ahmad Faiza; Abdullah @ Mohd Noor, Mashita

    2012-07-01

    A technique for the enhancement of Surface Plasmon Resonance (SPR) signal for sensing biomolecular interactions is described. Polyaniline (PANI) of particle size in the range of 1 to 15 nm was synthesized and used as the template for the immobilization of protein molecules. Biomolecular interactions of unbound and PANI-bound proteins with antibody molecules were SPR-monitored using a model system comprising of Bovine Serum Albumin (BSA) and anti BSA. A 7-fold increased in the signal was recorded from interactions of the PANI-bound BSA with anti BSA compared to the interactions of its unbound counterpart. This preliminary observation provides new avenue in immunosensor technology for improving the detection sensitivity of SPR biosensor; and thereby increasing the lower detection limit of biomolecules.

  12. High-sensitivity chemiluminescence immunoassays for detection of growth hormone doping in sports.

    Science.gov (United States)

    Bidlingmaier, Martin; Suhr, Jennifer; Ernst, Andrea; Wu, Zida; Keller, Alexandra; Strasburger, Christian J; Bergmann, Andreas

    2009-03-01

    Recombinant human growth hormone (rhGH) is abused in sports, but adequate routine doping tests are lacking. Analysis of serum hGH isoform composition has been shown to be effective in detecting rhGH doping. We developed and validated selective immunoassays for isoform analysis with potential utility for screening and confirmation in doping tests. Monoclonal antibodies with preference for pituitary hGH (phGH) or rhGH were used to establish 2 pairs of sandwich-type chemiluminescence assays with differential recognition of rhGH (recA and recB) and phGH (pitA and pitB). We analyzed specimens from volunteers before and after administration of rhGH and calculated ratios between the respective rec- and pit-assay results. Functional sensitivities were <0.05 microg/L, with intra- and interassay imprecision < or =8.4% and < or =13.7%, respectively. In 2 independent cohorts of healthy subjects, rec/pit ratios (median range) were 0.84 (0.09-1.32)/0.81 (0.27-1.21) (recA/pitA) and 0.68 (0.08-1.20)/0.80 (0.25-1.36) (recB/pitB), with no sex difference. In 20 recreational athletes, ratios (median SD) increased after a single injection of rhGH, reaching 350% (73%) (recA/pitA) and 400% (93%) (recB/pitB) of baseline ratios. At a moderate dose (0.033 mg/kg), mean recA/pitA and recB/pitB ratios remained significantly increased for 18 h (men) and 26 h (women). After high-dose rhGH (0.083 mg/kg), mean rec/pit ratios remained increased for 32 h (recA/pitA) and 34 h (recB/pitB) in men and were still increased after 36 h in women. Using sensitive chemiluminescence assays with preferential recognition of phGH or rhGH, detection of a single injection of rhGH was possible for up to 36 h.

  13. Biofunctionalization of aqueous dispersed, alumina membrane-templated polymer nanorods for use in enzymatic chemiluminescence assays.

    Science.gov (United States)

    Mark, Sonny S; Stolper, Samuel I; Baratti, Carla; Park, Jason Y; Kricka, Larry J

    2008-09-01

    The noncovalent immobilization of alkaline phosphatase (ALP) onto aqueous dispersed nylon 6 nanorods ( approximately 310 nm mean diameter; approximately 6 microm mean length) prepared by anodic aluminum oxide (AAO) membrane templating was studied. Using multi-stacked layer-by-layer (LBL) assembly with the cationic quaternary ammonium polymer Sapphire II , the amount of ALP enzyme loaded onto the polymer nanostructures was found to be 115+/-7 microg mg(-1) nanorod. The biofunctionalized nanorods were also characterized for their chemiluminescent activity with the dioxetane substrate, CSPD . The results indicate that the kinetic parameters, K(m) and V(max), for the catalytic activity of the nanostructure-bound ALP enzyme are different from those of soluble ('free') ALP. While the K(m) value was measured to be 156 microM for free ALP, the apparent K(m) value determined for the LBL-immobilized ALP is approximately 20% lower (122 microM). Furthermore, despite the relatively high enzyme loading capacity of the nanorods, the specific activity of the bound ALP enzyme was found to be almost nine times lower than that measured for free ALP. Finally, additional experiments revealed that the catalytic activities of both free ALP and nanorod-conjugated ALP are affected similarly by changes in pH, with optimal performance levels occurring under conditions of pH 9.5. To the best of our knowledge, this study represents the first report examining the preparation of aqueous dispersed, AAO-templated polymer nanorods for potential application as enzyme scaffolds in chemiluminescent-based assay systems.

  14. Hot electron-induced time-resolved electrogenerated chemiluminescence of a europium(III) label in fully aqueous solutions

    International Nuclear Information System (INIS)

    Jiang, Q.; Hakansson, M.; Spehar, A.-M.; Ahonen, J.; Ala-Kleme, T.; Kulmala, S.

    2006-01-01

    Time-resolved electrogenerated chemiluminescence of multidentate phenolic Eu(III) chelates were studied in aqueous solution. 2,6-bis[N,N-bis(carboxymethyl)-aminomethyl]-4-benzoylphenol forms a photoluminescent and electrochemiluminescent Eu(III) chelate, whereas 2,6-bis[N,N-bis(carboxymethyl)-aminomethyl]-4-methyl phenol-chelated Eu(III) turned out to be not luminescent at all. The importance of the redox properties of both the ground and the excited states of the ligands and the central ion is shown. The former chelate shows relatively weak ECL at an oxide-covered aluminum electrode but the ECL intensity can be strongly enhanced by the addition of peroxodisulfate ions. In the presence of 1 mM peroxodisulfate ions the ECL lifetime of this chelate is 0.94 ms, thus easily allowing time-resolved detection of the chelate. This chelate can be conjugated to antibodies by thioureido linkage and used as an electrochemiluminescent label in immunoassays as a marker which displays long-lived luminescence in the red end of the optical spectrum. The present ECL is mainly based on the ligand sensitized redox excitation of the chelate by analogous pathways to those known from the studies of aromatic Tb(III) chelates but the energy transfer from the emission centers of the aluminum oxide film can also have minor contribution to the excitation of the label

  15. Nanocomposites of gold nanoparticles and graphene oxide towards an stable label-free electrochemical immunosensor for detection of cardiac marker troponin-I

    International Nuclear Information System (INIS)

    Liu, Guozhen; Qi, Meng; Zhang, Yin; Cao, Chaomin; Goldys, Ewa M.

    2016-01-01

    A stable label-free amperometric immunosensor is presented based on gold nanoparticles and graphene oxide nanocomposites for detection of cardiac troponin-I in the early diagnosis of myocardial infarction. For designing of the sensing platform, firstly the nanocomposites based on GO and AuNPs were prepared and anchored on electrode surfaces. The formed nanocomposites provided a platform with big surface area for loading anti-cTnI capture antibody, and worked as a bridge for fast electron transfer subsequently increased the sensitivity. Moreover, the linkages between AuNP, GO, and electrodes were based on covalent bonding by aryldiazonium salt coupling chemistry, which favors the stability of the sensing interface. Finally, the anti-cTnI detection antibody was immobilized on GO tailored with ferrocene molecules, functioning as the signal reporter for the detection of cTnI. The modification process was monitored using electrochemistry, SEM, XPS. The herein immunosensor demonstrates a good selectivity and high sensitivity against human-cTnI, and is capable of detecting cTnI at concentrations as low as 0.05 ng mL −1 , which is 100 times lower than that possible by conventional methods. It is potential to design the portable sensing platform based on AuNPs and GO nanocomposites for future point-of-care diagnostics. - Highlights: • Nanocomposites based on GO and AuNPs were prepared and anchored on the electrode surfaces covalently to form a stable sensing interface. • The anti-cTnI detection antibody was immobilized on GO tailored with ferrocene molecules, functioning as the signal reporter for the detection of cTnI. • The detectable concentration of cTnI is 0.05 ng mL -1 in buffer with the assay time of less than 5 min. • The herein simple and novel approach for fabrication of AuNP and graphene based platform is promising for future fabrication of point-of-care devices.

  16. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    Science.gov (United States)

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  17. Determination of fluvoxamine maleate in human urine and human serum using alkaline KMnO4 -rhodamine B chemiluminescence.

    Science.gov (United States)

    Yang, Dongqin; He, Yanyan; Chen, Funan

    2017-09-01

    The flow-injection chemiluminescence (FI-CL) behavior of a gold nanocluster (Au NC)-enhanced rhodamine B-KMnO 4 system was studied under alkaline conditions for the first time. In the present study, the as-prepared bovine serum albumin-stabilized Au NCs showed excellent stability and reproducibility. The addition of trace levels of fluvoxamine maleate (Flu) led to an obvious decline in CL intensity in the rhodamine B-KMnO 4 -Au NCs system, which could be used for quantitative detection of Flu. Under optimized conditions, the proposed CL system exhibited a favorable analytical performance for Flu determination in the range 2 to 100 μg ml -1 . The detection limit for Flu measurement was 0.021 μg ml -1 . Moreover, this newly developed system revealed outstanding selectivity for Flu detection when compared with a multitude of other species, such as the usual ions, uric acid and a section of hydroxy compounds. Additionally, CL spectra, UV-visible spectroscopes and fluorescence spectra were measured in order to determine the possible reaction mechanism. This approach could be used to detect Flu in human urine and human serum samples with the desired recoveries and could have promising application under physiological conditions. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Recent advances in chemiluminescence detection coupled with capillary electrophoresis and microchip capillary electrophoresis.

    Science.gov (United States)

    Liu, Yuxuan; Huang, Xiangyi; Ren, Jicun

    2016-01-01

    CE is an ideal analytical method for extremely volume-limited biological microenvironments. However, the small injection volume makes it a challenge to achieve highly sensitive detection. Chemiluminescence (CL) detection is characterized by providing low background with excellent sensitivity because of requiring no light source. The coupling of CL with CE and MCE has become a powerful analytical method. So far, this method has been widely applied to chemical analysis, bioassay, drug analysis, and environment analysis. In this review, we first introduce some developments for CE-CL and MCE-CL systems, and then put the emphasis on the applications in the last 10 years. Finally, we discuss the future prospects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Chemiluminescence determination of tetracyclines using Fenton system in the presence europium(III) ions

    International Nuclear Information System (INIS)

    Kaczmarek, Malgorzata; Lis, Stefan

    2009-01-01

    A new simple chemiluminescent method for the determination of chlortetracycline (Chlor-TC), oxytetracycline (Oxy-TC) and doxycycline (Doxy-TC) is described. This method is based on the europium(III) emission as a result of the energy transfer process from the excited product of the tetracyclines oxidation to the uncomplexed Eu(III). Under the optimum conditions, calibration graphs were obtained for 4 x 10 -7 to 2 x 10 -5 mol L -1 of Chlor-TC; 2 x 10 -7 to 2 x 10 -5 mol L -1 of Oxy-TC and 1 x 10 -7 to 3 x 10 -5 mol L -1 of Doxy-TC. The method was successfully applied to the determination of these drugs in pharmaceutical and veterinary formulation and honey.

  20. Assessment of antioxidant activity of spray dried extracts of Psidium guajava leaves by DPPH and chemiluminescence inhibition in human neutrophils.

    Science.gov (United States)

    Fernandes, M R V; Azzolini, A E C S; Martinez, M L L; Souza, C R F; Lucisano-Valim, Y M; Oliveira, W P

    2014-01-01

    This work evaluated the physicochemical properties and antioxidant activity of spray dried extracts (SDE) from Psidium guajava L. leaves. Different drying carriers, namely, maltodextrin, colloidal silicon dioxide, Arabic gum, and β -cyclodextrin at concentrations of 40 and 80% relative to solids content, were added to drying composition. SDE were characterized through determination of the total phenolic, tannins, and flavonoid content. Antioxidant potential of the SDE was assessed by two assays: cellular test that measures the luminol-enhanced chemiluminescence (LumCL) produced by neutrophils stimulated with phorbol myristate acetate (PMA) and the DPPH radical scavenging (DPPH∗ method). In both assays the antioxidant activity of the SDE occurred in a concentration-dependent manner and showed no toxicity to the cells. Using the CLlum method, the IC50 ranged from 5.42 to 6.50 µg/mL. The IC50 of the SDE ranged from 7.96 to 8.11 µg/mL using the DPPH(•) method. Psidium guajava SDE presented significant antioxidant activity; thus they show high potential as an active phytopharmaceutical ingredient. Our findings in human neutrophils are pharmacologically relevant since they indicate that P. guajava SDE is a potential antioxidant and anti-inflammatory agent in human cells.

  1. A preliminary study of ester oxidation on an aluminum surface using chemiluminescence

    Science.gov (United States)

    Jones, William R., Jr.; Meador, Michael A.; Morales, Wilfredo

    1987-01-01

    The oxidation characteristics of a pure ester (trimethyolpropane triheptanoate) were studied by using a chemiluminescence technique. Tests were run in a thin-film micro-oxidation apparatus with an aluminum alloy catalyst. Conditions included a pure oxygen atmosphere and a temperature range of 176 to 206 C. Results indicated that oxidation of the ester (containing 10 to the minus 3rd power M diphenylanthracene as an intensifier) was accompanied by emission of light. The maximum intensity of light emission (I sub max) was a function of the amount of ester, the concentration of intensifier, and the test temperature. The induction period or the time to reach one-half of maximum intensity (t sub 1/2) was an inverse function of test temperature. Decreases in light emission at the later stages of a test were caused by depletion of the intensifier.

  2. Characterization of Diesel and Gasoline Compression Ignition Combustion in a Rapid Compression-Expansion Machine using OH* Chemiluminescence Imaging

    Science.gov (United States)

    Krishnan, Sundar Rajan; Srinivasan, Kalyan Kumar; Stegmeir, Matthew

    2015-11-01

    Direct-injection compression ignition combustion of diesel and gasoline were studied in a rapid compression-expansion machine (RCEM) using high-speed OH* chemiluminescence imaging. The RCEM (bore = 84 mm, stroke = 110-250 mm) was used to simulate engine-like operating conditions at the start of fuel injection. The fuels were supplied by a high-pressure fuel cart with an air-over-fuel pressure amplification system capable of providing fuel injection pressures up to 2000 bar. A production diesel fuel injector was modified to provide a single fuel spray for both diesel and gasoline operation. Time-resolved combustion pressure in the RCEM was measured using a Kistler piezoelectric pressure transducer mounted on the cylinder head and the instantaneous piston displacement was measured using an inductive linear displacement sensor (0.05 mm resolution). Time-resolved, line-of-sight OH* chemiluminescence images were obtained using a Phantom V611 CMOS camera (20.9 kHz @ 512 x 512 pixel resolution, ~ 48 μs time resolution) coupled with a short wave pass filter (cut-off ~ 348 nm). The instantaneous OH* distributions, which indicate high temperature flame regions within the combustion chamber, were used to discern the characteristic differences between diesel and gasoline compression ignition combustion. The authors gratefully acknowledge facilities support for the present work from the Energy Institute at Mississippi State University.

  3. Identification of gamma-irradiated foodstuffs by chemiluminescence measurements in Taiwan

    Science.gov (United States)

    Ma, Ming-Shia Chang; Chen, Li-Hsiang; Tsai, Zei-Tsan; Fu, Ying-Kai

    In order to establish chemiluminescence (CL) measurements as an identification method for γ-irradiated foodstuffs in Taiwan, ten agricultural products including wheat flour, rice, ginger, potatoes, garlic, onions, red beans, mung beans, soy beans, xanthoxylon seeds and Japanese star anises have been tested to compare CL intensities between untreated samples and samples subject to a 10 kGy γ-irradiation dose. Amongst them, wheat flour is the most eligible product to be identified by CL measurements. The CL intensities of un-irradiated and irradiated flour have shown large differences associated with a significant dose-effect relationship. Effects of three different protein contents of flour, unsieved and sieved (100-200 mesh), the reproducibility and the storage experiment on CL intensities at various doses were investigated in this study. In addition, the white bulb part of onions has shown some CL in irradiated samples. The CL data obtained from the other eight agricultural products have shown large fluctuations and cannot be used to differentiate between irradiated and un-irradiated samples.

  4. Identification of gamma-irradiated foodstuffs by chemiluminescence measurements in Taiwan

    International Nuclear Information System (INIS)

    Mingshia Chang Ma; Lihsiang Chen; Zeitsan Tsai; Yingkai Fu

    1992-01-01

    In order to establish chemiluminescence (CL) measurements as an identification method for γ-irradiated foodstuffs in Taiwan, ten agricultural products including wheat flour, rice, ginger, potatoes, garlic, onions, red beans, mung beans, soy beans, xanthoxylon seeds and Japanese star anises have been tested to compare CL intensities between untreated samples and samples subject to a 10 kGy γ-irradiation dose. Amongst them, wheat flour is the most eligible product to be identified by CL measurements. The CL intensities of un-irradiated and irradiated flour have shown large differences associated with a significant dose-effect relationship. Effects of three different protein contents of flour, unsieved and sieved (100-200 mesh), the reproducibility and the storage experiment on CL intensities at various doses were investigated in this study. In addition, the white bulb part of onions has shown some CL in irradiated samples. The CL data obtained from the other eight agricultural products have shown large fluctuations and cannot be used to differentiate between irradiated and un-irradiated samples. (Author)

  5. Optimization and development of a high-performance liquid chromatography-based one-site immunometric assay with chemiluminescence detection

    International Nuclear Information System (INIS)

    Oates, Matthew R.; Clarke, William; Zimlich, Alden; Hage, David S.

    2002-01-01

    Various practical and theoretical considerations were examined in the creation and optimization of a high-performance liquid chromatography (HPLC)-based one-site immunometric assay. This method used an HPLC analyte analog column and post-column chemiluminescence detection. The specific analyte chosen as the model for this study was L-thyroxine (also known as T 4 ). In this technique, a sample containing thyroxine was first combined with an excess of anti-T 4 antibody Fab fragments that had earlier been conjugated with chemiluminescent acridinium ester labels. After incubation, the mixture was injected onto a column that contained immobilized T 4 . The amount of thyroxine in the original sample was then determined by measuring the labeled Fab fragments that appeared in the non-retained fraction, or the decrease in excess Fab fragments that were bound to and later eluted from the column. Items considered in creating this assay included the preparation of acridinium ester-labeled Fab fragments, the detection of these fragments with a post-column reactor, and the creation of a suitable immobilized analog column for capturing excess labeled Fab fragments. The final method could measure T 4 in standards at clinically-relevant concentrations and provided a response within 1.5 min of sample injection, following a 20-45 min incubation with the labeled Fab fragments. Possible applications of this method include its use in clinical chemistry and the screening of proteomic or combinatorial libraries

  6. Quantitative differentiation of multiple virus in blood using nanoporous silicon oxide immunosensor and artificial neural network.

    Science.gov (United States)

    Chakraborty, W; Ray, R; Samanta, N; RoyChaudhuri, C

    2017-12-15

    In spite of the rapid developments in various nanosensor technologies, it still remains challenging to realize a reliable ultrasensitive electrical biosensing platform which will be able to detect multiple viruses in blood simultaneously with a fairly high reproducibility without using secondary labels. In this paper, we have reported quantitative differentiation of Hep-B and Hep-C viruses in blood using nanoporous silicon oxide immunosensor array and artificial neural network (ANN). The peak frequency output (f p ) from the steady state sensitivity characteristics and the first cut off frequency (f c ) from the transient characteristics have been considered as inputs to the multilayer ANN. Implementation of several classifier blocks in the ANN architecture and coupling them with both the sensor chips, functionalized with Hep-B and Hep-C antibodies have enabled the quantification of the viruses with an accuracy of around 95% in the range of 0.04fM-1pM and with an accuracy of around 90% beyond 1pM and within 25nM in blood serum. This is the most sensitive report on multiple virus quantification using label free method. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Microconductometric Detection of Bacterial Contamination

    Directory of Open Access Journals (Sweden)

    Sarra EL ICHI

    2014-05-01

    Full Text Available Several approaches can be used for the electrochemical detection of bacterial contamination. Their performance can be assessed by the ability to detect bacteria at very low concentrations within a short-time response. We have already demonstrated that a conductometric biosensor based on interdigitated thin-film electrodes is adapted to detect bacteria in clinical samples like serum and compatible with microfluidic fabrication. The type of interdigitated microelectrodes influences the performance of the biosensor. This was shown by the results obtained in this work. A magnetic-nanoparticles based immunosensor was designed using gold screen-printed electrodes. The immunosensor was able to specifically detect E. coli in the range of 1-103 CFU mL-1. The new transducer offered a larger active sensing surface with a lower cost and a robust material. Accuracy of the conductance value was enhanced by differential measurements. The immunosensor is compatible with a microfluidic system.

  8. Disposable Electrochemical Immunosensor Diagnosis Device Based on Nanoparticle Probe and Immunochromatographic Strip

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guodong; Lin, Ying-Ying; Wang, Jun; Wu, Hong; Wai, Chien M.; Lin, Yuehe

    2007-10-15

    We describe a disposable electrochemical immunosensor diagnosis device that is based on the immunochromatographic strip technique and an electrochemical immunoassay based on quantum dot (QD, CdS@ZnS) labels. The device takes advantage of the speed and low-cost of the conventional immunochromatographic strip test and the high-sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1 to 10 ng mL-1 IgG, and the limit of detection is estimated to be 30 pg mL-1 in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL-1 using a 20-min immunoreaction time. The new disposable electrochemical diagnosis device thus provides a more user-friendly, rapid, clinically accurate, less expensive, and quantitative tool for protein detection.

  9. Using reduced graphene oxide-Ca:CdSe nanocomposite to enhance photoelectrochemical activity of gold nanoparticles functionalized tungsten oxide for highly sensitive prostate specific antigen detection.

    Science.gov (United States)

    Wang, Xueping; Xu, Rui; Sun, Xu; Wang, Yaoguang; Ren, Xiang; Du, Bin; Wu, Dan; Wei, Qin

    2017-10-15

    An ultrasensitive sandwich-type photoelectrochemical (PEC) immunosensor was constructed for the detection of prostate specific antigen (PSA). In this work, Au-nanoparticle-loaded tungsten oxide (WO 3 -Au) hybrid composites was applied as PEC sensing platform, while Ca ions doped CdSe equipped on the conducting framework of reduced graphene oxide (rGO-Ca:CdSe) nanocomposites were employed as the signal amplification probe. As for WO 3 -Au, massive Au nanoparticles were formed on the surface of WO 3 without any additional reducing agent, providing a novel nanocarriers for anchoring plenty of the primary antibodies due to the large specific surface area and good biocompatibility by chemical bonding between Au nanoparticles and -NH 2 of antibodies. Besides, the incorporation of the rGO and the doping of Ca ions could improve the conductivity and hinder the recombination of electron-hole pairs of CdSe nanoparticles effectively, thereby enhancing the photocurrent conversion efficiency. Based on the sandwich immunoreaction, the primary antibody was immobilized onto WO 3 -Au substrate, after the formed rGO-Ca:CdSe labels were captured onto the electrode surface via the specific antibody-antigen interaction, the photocurrent intensity could be further enhanced due to the sensitization effect. Under the optimal conditions, the proposed PEC immunosensor shows a linear relationship between photocurrent variation and the logarithm of PSA concentration in the wide range of 5pgmL -1 to 50ngmL -1 with a low detection limit of 2.6pgmL -1 (S/N=3). Moreover, it also presented good stability and acceptable specificity, indicating the potential applications in clinical diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Chemiluminescence determination of tetracyclines using Fenton system in the presence europium(III) ions

    Energy Technology Data Exchange (ETDEWEB)

    Kaczmarek, Malgorzata [Department of Rare Earths, Faculty of Chemistry, Adam Mickiewicz University, Grunwaldzka 6, 60 - 780 Poznan (Poland); Lis, Stefan [Department of Rare Earths, Faculty of Chemistry, Adam Mickiewicz University, Grunwaldzka 6, 60 - 780 Poznan (Poland)

    2009-04-20

    A new simple chemiluminescent method for the determination of chlortetracycline (Chlor-TC), oxytetracycline (Oxy-TC) and doxycycline (Doxy-TC) is described. This method is based on the europium(III) emission as a result of the energy transfer process from the excited product of the tetracyclines oxidation to the uncomplexed Eu(III). Under the optimum conditions, calibration graphs were obtained for 4 x 10{sup -7} to 2 x 10{sup -5} mol L{sup -1} of Chlor-TC; 2 x 10{sup -7} to 2 x 10{sup -5} mol L{sup -1} of Oxy-TC and 1 x 10{sup -7} to 3 x 10{sup -5} mol L{sup -1} of Doxy-TC. The method was successfully applied to the determination of these drugs in pharmaceutical and veterinary formulation and honey.

  11. Molecular imprinting-chemiluminescence determination of trimethoprim using trimethoprim-imprinted polymer as recognition material.

    Science.gov (United States)

    He, Yunhua; Lu, Jiuru; Liu, Mei; Du, Jianxiu

    2005-07-01

    A new molecular imprinting-chemiluminescence method for the determination of trimethoprim was developed, in which trimethoprim-imprinted polymer was used as the molecular recognition material and the CL reaction of trimethoprim with potassium permanganate in acidic medium was used as the detection system. The CL intensity responds linearly to the concentration of trimethoprim within the 5.0 x 10(-8)-5.0 x 10(-6) g mL(-1) range (r= 0.9983) with a detection limit of 2 x 10(-8) g mL(-1). The relative standard deviation for the determination of 1.0 x 10(-7) g mL(-1) trimethoprim solutions is 4.8% (n= 9). The method has been applied to the determination of trimethoprim in pharmaceutical preparations and body fluids, and satisfactory results were obtained.

  12. A chemiluminescence reagent free method for the determination of captopril in medicine and urine samples by using trivalent silver

    Directory of Open Access Journals (Sweden)

    Zhaofu Fu

    2017-08-01

    Full Text Available A novel flow-injection chemiluminescence (FI-CL method free of CL reagent was developed for the determination of captopril based on its enhancing effect on the CL derived from diperiodatoargentate(III-sulfuric acid system. Compared with the conventional CL system, the CL system based on trivalent silver was characterized of good selectivity for the absence of CL reagent. The CL mechanism was discussed through CL spectra and UV–vis absorption spectra. The conditions of the FI-CL system were investigated and optimized. Under the optimal conditions, the relative CL intensity was linear with the captopril concentration in the range of 0.3–15.0 μg/mL. The detection limit for captopril was 0.05 μg/mL, and the relative standard deviation (n=11 was 2.0% for 5.0 μg/mL captopril. The proposed method was applied to the analysis of captopril in tablet and human urine with the recoveries of 83.1%–112.5%, and the relative standard deviations of 0.5%–4.4%. The results obtained by the proposed method agreed well with those obtained from HPLC method. The proposed method is fast, convenient, and cost-effective for the determination of captopril in medicine and biological samples.

  13. Study of immunoglobulin G thin layers obtained by the Langmuir-Blodgett method: application to immunosensors.

    Science.gov (United States)

    Barraud, A; Perrot, H; Billard, V; Martelet, C; Therasse, J

    1993-01-01

    Nowadays, immunosensors play a leading part in the field of bioanalytical chemistry research. As with any biosensor, they need appropriate transducers and a suitable technique to immobilize the active biocomponents. In this study, two transduction modes were chosen: mass effects (quartz microbalance measurements) and geometric and dielectric effects (capacitance measurements). The Langmuir-Blodgett (LB) method appears to be quite suitable for generating biospecific surfaces. This work has focused on the detection of staphylococcal enterotoxin B, the corresponding antibody being immobilized at the surface of fatty acids by a variant of the LB method. The composition of the film and the nature of antibody-fatty acid interactions were studied by means of the two transducers mentioned above. FTIR (Fourier transform infra-red) spectroscopy and protein diagnostic assay. Influence of several parameters (pH, ionic strength, transfer pressure, antibody concentration in the subphase) was investigated. The immobilization rate reached its maximum when experimental conditions allowed optimal electrostatic interactions. In this case, the quartz crystal microbalance response, in air, reached 55 Hz per monolayer of immobilized immunoglobulin G and the equivalent capacitance variation, measured in liquid media, was around 300 pF cm-2. Activity of the biospecific LB films, when binding enterotoxin, was checked by the classical ELISA (enzyme immuno-linked assay) technique.

  14. Luminol functionalized gold nanoparticles as colorimetric and chemiluminescent probes for visual, label free, highly sensitive and selective detection of minocycline

    Science.gov (United States)

    He, Yi; Peng, Rufang

    2014-11-01

    In this work, luminol functionalized gold nanoparticles (LuAuNPs) were used as colorimetric and chemiluminescent probes for visual, label free, sensitive and selective detection of minocycline (MC). The LuAuNPs were prepared by simple one-pot reduction of HAuCl4 with luminol, which exhibited a good chemiluminescence (CL) activity owing to the presence of luminol molecules on their surface and surface plasmon resonance absorption. In the absence of MC, the color of LuAuNPs was wine red and their size was relatively small (˜25 nm), which could react with silver nitrate, producing a strong CL emission. Upon the addition of MC at acidic buffer solutions, the electrostatic interaction between positively charged MC and negatively charged LuAuNPs caused the aggregation of LuAuNPs, generating a purple or blue color. Simultaneously, the aggregated LuAuNPs did not effectively react with silver nitrate, producing a weak CL emission. The signal change was linearly dependent on the logarithm of MC concentration in the range from 30 ng to 1.0 μg for colorimetric detection and from 10 ng to 1.0 μg for CL detection. With colorimetry, a detection limit of 22 ng was achieved, while the detection limit for CL detection modality was 9.7 ng.

  15. Luminol functionalized gold nanoparticles as colorimetric and chemiluminescent probes for visual, label free, highly sensitive and selective detection of minocycline

    International Nuclear Information System (INIS)

    He, Yi; Peng, Rufang

    2014-01-01

    In this work, luminol functionalized gold nanoparticles (LuAuNPs) were used as colorimetric and chemiluminescent probes for visual, label free, sensitive and selective detection of minocycline (MC). The LuAuNPs were prepared by simple one-pot reduction of HAuCl 4 with luminol, which exhibited a good chemiluminescence (CL) activity owing to the presence of luminol molecules on their surface and surface plasmon resonance absorption. In the absence of MC, the color of LuAuNPs was wine red and their size was relatively small (∼25 nm), which could react with silver nitrate, producing a strong CL emission. Upon the addition of MC at acidic buffer solutions, the electrostatic interaction between positively charged MC and negatively charged LuAuNPs caused the aggregation of LuAuNPs, generating a purple or blue color. Simultaneously, the aggregated LuAuNPs did not effectively react with silver nitrate, producing a weak CL emission. The signal change was linearly dependent on the logarithm of MC concentration in the range from 30 ng to 1.0 μg for colorimetric detection and from 10 ng to 1.0 μg for CL detection. With colorimetry, a detection limit of 22 ng was achieved, while the detection limit for CL detection modality was 9.7 ng. (paper)

  16. Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads

    International Nuclear Information System (INIS)

    Zhang Ruiq; Nakajima, Hizuru; Soh, Nobuaki; Nakano, Koji; Masadome, Takashi; Nagata, Kazumi; Sakamoto, Kazuhira; Imato, Toshihiko

    2007-01-01

    A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm

  17. Highly sensitive chemiluminescent point mutation detection by circular strand-displacement amplification reaction.

    Science.gov (United States)

    Shi, Chao; Ge, Yujie; Gu, Hongxi; Ma, Cuiping

    2011-08-15

    Single nucleotide polymorphism (SNP) genotyping is attracting extensive attentions owing to its direct connections with human diseases including cancers. Here, we have developed a highly sensitive chemiluminescence biosensor based on circular strand-displacement amplification and the separation by magnetic beads reducing the background signal for point mutation detection at room temperature. This method took advantage of both the T4 DNA ligase recognizing single-base mismatch with high selectivity and the strand-displacement reaction of polymerase to perform signal amplification. The detection limit of this method was 1.3 × 10(-16)M, which showed better sensitivity than that of most of those reported detection methods of SNP. Additionally, the magnetic beads as carrier of immobility was not only to reduce the background signal, but also may have potential apply in high through-put screening of SNP detection in human genome. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Resonance energy transfer between ZnCdHgSe quantum dots and gold nanorods enhancing photoelectrochemical immunosensing of prostate specific antigen

    International Nuclear Information System (INIS)

    Wang, Yanying; Yu, Xiangyang; Ye, Xiaoxue; Wu, Kangbing; Wu, Tsunghsueh; Li, Chunya

    2016-01-01

    Gold nanorods (AuNRs) integrated with ZnCdHgSe near-infrared quantum dots (AuNRs-ZnCdHgSe QDs) were successfully synthesized and characterized by transmission electron microscope, X-ray photoelectron spectroscopy, and X-ray diffraction. A glassy carbon electrode was decorated with the aforementioned AuNRs-ZnCdHgSe QDs nanocomposite, which provides a biocompatible interface for the subsequent immobilization of prostate specific antibody (anti-PSA). After being successively treated with glutaraldehyde vapor and bovine serum albumin solution, a photoelectrochemical immunosensing platform based on anti-PSA/AuNRs-ZnCdHgSe QDs/GCE was established. The photocurrent response of ZnCdHgSe QDs was tremendously improved by AuNRs due to the effect of resonance energy transfer which can be deduced from the dependence of the enhanced efficiency on the AuNRs with different length-to-diameter ratios and spectral absorption characteristics. A maximum photocurrent was obtained when the absorption spectrum of AuNRs matched well with the emission spectrum of ZnCdHgSe QDs. A photoelectrochemical immunosensor for prostate specific antigen (PSA) was achieved by monitoring the photocurrent variation. The photocurrent variation before and after being interacted with PSA solution exhibits a good linear relationship with the logarithm of its concentration (logc_P_S_A) in the range from 1.0 pg mL"−"1 to 50.0 ng mL"−"1. The detection limit of this photoelectrochemical immunosensor is able to reach 0.1 pg mL"−"1 (S/N = 3). Determining PSA in clinical human serum was also demonstrated by using the developed anti-PSA(BSA)/AuNRs-ZnCdHgSe QDs/GCE electrode. The results were comparable with those obtained from an enzyme-linked immunosorbent assay method. - Highlights: • Nanocomposites based on AuNRs integration with ZnCdHgSe QDs were synthesized. • The photocurrent response of ZnCdHgSe QDs was improved by resonance energy transfer. • A photoelectrochemical immunosensor was

  19. Resonance energy transfer between ZnCdHgSe quantum dots and gold nanorods enhancing photoelectrochemical immunosensing of prostate specific antigen

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yanying [Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan 430074 (China); Key Laboratory for Material Chemistry of Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Yu, Xiangyang; Ye, Xiaoxue [Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan 430074 (China); Wu, Kangbing [Key Laboratory for Material Chemistry of Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Wu, Tsunghsueh [Department of Chemistry, University of Wisconsin-Platteville, 1 University Plaza, Platteville, WI 53818-3099 (United States); Li, Chunya, E-mail: lichychem@163.com [Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan 430074 (China)

    2016-11-02

    Gold nanorods (AuNRs) integrated with ZnCdHgSe near-infrared quantum dots (AuNRs-ZnCdHgSe QDs) were successfully synthesized and characterized by transmission electron microscope, X-ray photoelectron spectroscopy, and X-ray diffraction. A glassy carbon electrode was decorated with the aforementioned AuNRs-ZnCdHgSe QDs nanocomposite, which provides a biocompatible interface for the subsequent immobilization of prostate specific antibody (anti-PSA). After being successively treated with glutaraldehyde vapor and bovine serum albumin solution, a photoelectrochemical immunosensing platform based on anti-PSA/AuNRs-ZnCdHgSe QDs/GCE was established. The photocurrent response of ZnCdHgSe QDs was tremendously improved by AuNRs due to the effect of resonance energy transfer which can be deduced from the dependence of the enhanced efficiency on the AuNRs with different length-to-diameter ratios and spectral absorption characteristics. A maximum photocurrent was obtained when the absorption spectrum of AuNRs matched well with the emission spectrum of ZnCdHgSe QDs. A photoelectrochemical immunosensor for prostate specific antigen (PSA) was achieved by monitoring the photocurrent variation. The photocurrent variation before and after being interacted with PSA solution exhibits a good linear relationship with the logarithm of its concentration (logc{sub PSA}) in the range from 1.0 pg mL{sup −1} to 50.0 ng mL{sup −1}. The detection limit of this photoelectrochemical immunosensor is able to reach 0.1 pg mL{sup −1} (S/N = 3). Determining PSA in clinical human serum was also demonstrated by using the developed anti-PSA(BSA)/AuNRs-ZnCdHgSe QDs/GCE electrode. The results were comparable with those obtained from an enzyme-linked immunosorbent assay method. - Highlights: • Nanocomposites based on AuNRs integration with ZnCdHgSe QDs were synthesized. • The photocurrent response of ZnCdHgSe QDs was improved by resonance energy transfer. • A photoelectrochemical

  20. Electrogenerated chemiluminescence quenching of Ru(bpy){sub 3} {sup 2+} (bpy=2,2 Prime -bipyridine) in the presence of acetaminophen, salicylic acid and their metabolites

    Energy Technology Data Exchange (ETDEWEB)

    Haslag, Catherine S. [Department of Chemistry, Missouri State University, Springfield, Missouri 65897 (United States); Richter, Mark M., E-mail: MarkRichter@missouristate.edu [Department of Chemistry, Missouri State University, Springfield, Missouri 65897 (United States)

    2012-03-15

    Quenching of Ru(bpy) {sub 3}{sup 2+} (bpy=2,2 Prime -bipyridine) coreactant electrogenerated chemiluminescence (ECL) has been observed in the presence of acetaminophen, salicylic acid and related complexes. However, no quenching is observed with the acetylsalicylic acid. In most instances, quenching is observed with 100-fold excess of quencher (compared to ECL luminophore) with complete quenching observed between 10,000 and 100,000 fold excess. Fluorescence and UV-vis experiments coupled with bulk electrolysis support the formation of benzoquinone products upon electrochemical oxidation. The mechanism of quenching may involve the interaction of the electrochemically generated benzoquinone species with (i) the {sup Low-Asterisk }Ru(bpy){sub 3}{sup 2+} excited state or (ii) highly energetic coreactant radicals. - Highlights: Black-Right-Pointing-Triangle Efficient quenching of the electrogenerated chemiluminescence is observed. Black-Right-Pointing-Triangle Acetaminophen, salicylic acid and related compounds can be detected. Black-Right-Pointing-Triangle The mechanism of quenching involves benzoquinones formed upon electrolysis.

  1. Electrochemiluminescence behavior of AgNCs and its application in immunosensors based on PANI/PPy-Ag dendrite-modified electrode.

    Science.gov (United States)

    Zhang, Lina; Wang, Yanhu; Shen, Lei; Yu, Jinghua; Ge, Shenguang; Yan, Mei

    2017-07-10

    In this study, hyperbranched polyethyleneimine-protected silver nanoclusters (hPEI-AgNCs) with excellent electrochemiluminescence (ECL) emission in the presence of coreactant K 2 S 2 O 8 were prepared by chemical reduction of silver ions (silver nitrate) coordinated with dendrigraft polymer, and successfully used for the construction of an ECL immunosensor. Polyaniline (PANI)/polypyrrole (PPy)-silver (Ag) dendrites with good electrical conductivity and biocompatibility were electropolymerized on the surface of indium tin oxide (ITO) electrode as carriers. Porous ZnO sphere-loaded hPEI-AgNCs-induced signal amplification strategies were integrated exquisitely and applied sufficiently. Taking carcinoembryonic antigen (CEA) as an example, under optimal conditions, the CEA concentration was determined to be in the range of 10 -3 ng mL -1 -100 ng mL -1 and with a detection limit of 0.4 pg mL -1 using this method; it exhibited excellent selectivity, high stability, and acceptable fabrication reproducibility. It was anticipated that hPEI-AgNCs would have promising applications in green, selective, and sensitive detection of target analytes in the future.

  2. Disposable Amperometric Immunosensor for the Determination of Human P53 Protein in Cell Lysates Using Magnetic Micro-Carriers

    Directory of Open Access Journals (Sweden)

    María Pedrero

    2016-11-01

    Full Text Available An amperometric magnetoimmunosensor for the determination of human p53 protein is described in this work using a sandwich configuration involving the covalent immobilization of a specific capture antibody onto activated carboxylic-modified magnetic beads (HOOC-MBs and incubation of the modified MBs with a mixture of the target protein and horseradish peroxidase-labeled antibody (HRP-anti-p53. The resulting modified MBs are captured by a magnet placed under the surface of a disposable carbon screen-printed electrode (SPCE and the amperometric responses are measured at −0.20 V (vs. an Ag pseudo-reference electrode, upon addition of hydroquinone (HQ as a redox mediator and H2O2 as the enzyme substrate. The magnetoimmunosensing platform was successfully applied for the detection of p53 protein in different cell lysates without any matrix effect after a simple sample dilution. The results correlated accurately with those provided by a commercial ELISA kit, thus confirming the immunosensor as an attractive alternative for rapid and simple determination of this protein using portable and affordable instrumentation.

  3. A novel chemiluminescence assay of organophosphorous pesticide quinalphos residue in vegetable with luminol detection

    Directory of Open Access Journals (Sweden)

    Yao Xin

    2010-06-01

    Full Text Available Abstract Background Organophosphorous pesticides are the most popular pesticides used in agriculture. As acetylcholinesterase inhibitors, organophosphorous pesticides are toxic organic chemicals. The control and detection of organophosphorous pesticide residue in food, water, and environment therefore plays a very important role in maintaining physical health. A sensitive, rapid, simple chemiluminescence(CL method has been developed for the determination of quinalphos based on the reaction of quinalphos with luminol-H2O2 in an alkaline medium. The method has been applied to detection of quinalphos in vegetable samples with satisfactory results. Results The CL method for the determination of organophosphorous pesticide quinalphos is based on the phenomenon that quinalphos can apparently enhance the CL intensity of the luminol-H2O2 system. The optimal conditions were: luminol concentration 5.0 × 10-4 mol/L, H2O2 concentration 0.05 mol/L.pH value 13. In order to restrain the interference from metal ions, 1.0 × 10-3 mol/L of EDTA was added to the luminol solution. The possible mechanism was proposed. Conclusion Under the optimum reaction conditions, CL was linear with the concentration of quinalphos in the range of 0.02 μg/mL -1.0 μg/mL and the detection limit was 0.0055 μg/mL (3σ. This method has been successfully applied to the detection of quinalphos in vegetable samples. According to the experimental data, the average recoveries for quinalphos in cherry tomato and green pepper 97.20% and 90.13%. Meanwhile, the possible mechanism was proposed.

  4. Comparison of comprehensive two-dimensional gas chromatography coupled with sulfur-chemiluminescence detector to standard methods for speciation of sulfur-containing compounds in middle distillates.

    Science.gov (United States)

    Ruiz-Guerrero, Rosario; Vendeuvre, Colombe; Thiébaut, Didier; Bertoncini, Fabrice; Espinat, Didier

    2006-10-01

    The monitoring of total sulfur content and speciation of individual sulfur-containing compounds in middle distillates is required for efficient catalyst selection and for a better understanding of the kinetics of the reactions involved in hydrotreament processes. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GCxGC) hyphenated to sulfur chemiluminescence detection (SCD) has recently evolved as a powerful tool for improving characterization and identification of sulfur compounds. The aim of this paper is to compare quantitatively GCxGC-SCD and various other methods commonly employed in the petroleum industry, such as X-ray fluorescence, conventional GC-SCD, and high-resolution mass spectrometry, for total sulfur content determination and speciation analysis. Different samples of middle distillates have been analyzed to demonstrate the high potential and important advantages of GCxGC-SCD for innovative and quantitative analysis of sulfur-containing compounds. More accurate and detailed results for benzothiophenes and dibenzothiophenes are presented, showing that GCxGC-SCD should become, in the future, an essential tool for sulfur speciation analysis.

  5. The effect of supportive E. coli mastitis treatment on PMN chemiluminescence and subpopulations of T lymphocytes.

    Science.gov (United States)

    Markiewicz, H; Krumrych, W; Gehrke, M

    2013-01-01

    The aim of this field study was to assess the impact of a single i.m. injection of lysozyme dimer and flunixin meglumine in combination with intramammary and systemic antibiotic on chemiluminescence of PMN (polymorphonuclear leucocytes) and subpopulations of lymphocyte T in blood of cows with E. coli mastitis. Examinations were performed on 30 dairy cows affected with naturally occurring acute form of E. coli mastitis. Cows were randomly divided into three groups according to the method of treatment. The first group was treated with approved intramammary antibiotic product, the same antibiotic in i.m. injection and one injection of flunixin meglumine on the first day of therapy. Next group was treated with the same antibiotic and additionally one injection of lysozyme dimer on the first day of therapy. The third one was treated only with an antibiotic and served as a control group. Blood samples were taken before treatment and on days 3 and 7. In samples haematology indices were determined, spontaneous and opsonised zymosan stimulated CL and PMA measurements were performed and the subpopulations of T lymphocyte (CD2(+), CD4(+), CD8(+)) were assayed in whole blood. There was no effect of the applied supportive treatment on the value of morphological blood indices. A significant influence of the time of sample collection on the level of CL and dynamics of lymphocytes T subpopulation was demonstrated. A single injection of flunixin meglumine or lysozyme dimer on the day of the beginning of treatment of E. coli mastitis, does not affect the level of neutrophil chemiluminescence and the percentage of T lymphocytes in the blood of mastitic cows in the analysed period of time.

  6. Design and Development of a Microfluidic Amperometric Immunosensor for the Quantitative Detection of 2,6-dichlorobenzamide (BAM) Herbicide Residue in Ground Water

    DEFF Research Database (Denmark)

    Uthuppu, Basil

    Access to clean and safe-drinking water is essential to health and it is a basic human right. These days, nearly a billion people of the world‘s population do not have access to this precious commodity. Along with many other causes, pollution of water sources by pesticides poses a real threat...... to the availability of clean water. Thus, the need of rapid, reliable and on-site early warning systems to monitor the quality of water becomes as important as its preservation. This work describes the design and development of an automated microfluidic biosensor based on immunological methods (immunosensor......-point analysis technique (ELISA) to a portable, onsite monitoring system. The optimization of this heterogeneous competitive immunoassay is achieved by a unique approach in which the immunosorbent is engineered by using a newly synthesised BAM hapten library. Additionally, the improvisations made to the existing...

  7. Covalent immobilization of rabbit-antiaflatoxin-antibodies onto the poly-acrylamideacrylonitrile as well as hybrid material UREASIL and developing an optical immunosensor

    Directory of Open Access Journals (Sweden)

    Slavova M.

    2017-03-01

    Full Text Available The aim of this work is to describe a covalent immobilization of antibodies onto the poly- acrylamide-acrylonitrile or hybrid material UREASIL and creation of optical immunosensor for determination of aflatoxin Bl. For this purpose, mouse-anti-aflatoxin B1 antibodies with oxidized carbohydrate moieties were covalently immobilized on the membranes of polyacrylamide- polyacrylonitrile copolymer, as well as the hybrid material UREASIL. To determine the affinity> binding of the immobilized antibody with afatoxin Bl was used "sandwich" method. Associated with the immobilized antibody sought ingredients interact with a surplus of secondary’ signal antibodies. The described method has been developed as a model system, which can easily be applied for the determination of aflatoxins in samples of different origin. To the best of our knowledge, this is the first study to show that in the establishment of biosensor was used hybrid material UREASIL.

  8. Optimization of condition for conjugation of enrofloxacin to enzymes in chemiluminescence enzyme immunoassay

    Science.gov (United States)

    Yu, Songcheng; Yu, Fei; Zhang, Hongquan; Qu, Lingbo; Wu, Yongjun

    2014-06-01

    In this study, in order to find out a proper method for conjugation of enrofloxacin to label enzymes, two methods were compared and carbodiimide condensation was proved to be better. The results showed that the binding ratio of enrofloxacin and alkaline phosphatase (ALP) was 8:1 and that of enrofloxacin and horseradish peroxidase (HRP) was 5:1. This indicated that conjugate synthesized by carbodiimide condensation was fit for chemiluminescence enzyme immunoassay (CLEIA). Furthermore, data revealed that dialysis time was an important parameter for conjugation and 6 days was best. Buffer to dilute conjugate had little effect on CLEIA. The storage condition for conjugates was also studied and it was shown that the conjugate was stable at 4 °C with no additive up to 30 days. These data were valuable for establishing CLEIA to quantify enrofloxacin.

  9. Flow injection gas chromatography with sulfur chemiluminescence detection for the analysis of total sulfur in complex hydrocarbon matrixes.

    Science.gov (United States)

    Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim

    2018-01-01

    A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Assessment of Antioxidant Activity of Spray Dried Extracts of Psidium guajava Leaves by DPPH and Chemiluminescence Inhibition in Human Neutrophils

    Directory of Open Access Journals (Sweden)

    M. R. V. Fernandes

    2014-01-01

    Full Text Available This work evaluated the physicochemical properties and antioxidant activity of spray dried extracts (SDE from Psidium guajava L. leaves. Different drying carriers, namely, maltodextrin, colloidal silicon dioxide, Arabic gum, and β-cyclodextrin at concentrations of 40 and 80% relative to solids content, were added to drying composition. SDE were characterized through determination of the total phenolic, tannins, and flavonoid content. Antioxidant potential of the SDE was assessed by two assays: cellular test that measures the luminol-enhanced chemiluminescence (LumCL produced by neutrophils stimulated with phorbol myristate acetate (PMA and the DPPH radical scavenging (DPPH* method. In both assays the antioxidant activity of the SDE occurred in a concentration-dependent manner and showed no toxicity to the cells. Using the CLlum method, the IC50 ranged from 5.42 to 6.50 µg/mL. The IC50 of the SDE ranged from 7.96 to 8.11 µg/mL using the DPPH• method. Psidium guajava SDE presented significant antioxidant activity; thus they show high potential as an active phytopharmaceutical ingredient. Our findings in human neutrophils are pharmacologically relevant since they indicate that P. guajava SDE is a potential antioxidant and anti-inflammatory agent in human cells.

  11. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  12. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  13. Measurements in international units of antibody to hepatitis B surface antigen(anti-HBs) after immunization with a yeast-derived, subtype adr hepatitis B vaccine are considerably different between chemiluminescent immunoassay (CLIA) and chemiluminescent enzyme immunoassay (CLEIA).

    Science.gov (United States)

    Ogata, Norio

    2006-04-01

    The worldwide consensus of the minimum protective anti-HBs level against HBV infection is 10 mIU/mL on assays standardized by the World Health Organization (WHO) reference preparations. To investigate whether this value could be applied to recipients of yeast-derived recombinant HB vaccine containing the major surface protein of subtype adr (Bimmugen, Astellas Pharmaceutical, Tokyo), we compared anti-HBs measurements between chemiluminescent immunoassay (CLIA) (Architect Ausab, Abbott Japan, Tokyo) and chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse Forte, Fujirebio, Tokyo) in given serum samples obtained from the vaccinees. The vaccine and the two assay methods are currently in a wide use in Japan. The study included 300 medical students who completed a standard vaccination course (0, 1 and 6 months). Serum samples obtained 1 month or 13 months after completing the vaccination were simultaneously tested for anti-HBs by CLIA and CLEIA. In 147 samples with quantifiable values on both CLIA and CLEIA (10 to 1000 mIU/mL) the geometric mean titer on CLEIA (225.0 mIU/mL) was significantly higher than that on CLIA (94.5 mIU/mL) (p < 0.0001). Of 26 subjects with CLIA measurements below 10 mIU/mL, 15 samples (57.7%) showed CLEIA measurements more than 10 mIU/mL. Thus, in the subtype adr-vaccinees CLEIA demonstrated considerably high serum anti-HBs measurements compared to CLIA and discordance in determining critical anti-HBs level of 10 mIU/mL was observed in more than half the samples. This suggests that the minimum HBV-protective anti HBs titer of 10 mIU/mL is difficult to be introduced to Japan where subtype adr-HB vaccines or -HBV infection are prevalent, unless characteristics of assay methods are carefully evaluated.

  14. Electro chemiluminescence Biosensor Based on Thioglycolic Acid-Capped Cd Se QDs for Sensing Glucose

    International Nuclear Information System (INIS)

    Jung, E. Y.; Ye, J. H.; Choi, S. H.; Jung, S. H.

    2016-01-01

    In order to detect low level glucose concentration, an electro chemiluminescence (ECL) biosensor based on TGA-capped Cd Se quantum dots (QDs) was fabricated by the immobilization of Cd Se QDs after modifying the surface of a glassy carbon electrode (GCE) with 4-amino thiophenol diazonium salts by the electrochemical method. For the detection of glucose concentration, glucose oxidase (GOD) was immobilized onto the fabricated Cd Se QDs-modified electrode. The fabricated ECL biosensor based on TGA-capped Cd Se QDs was characterized using a scanning electron microscope (SEM), UV-vis spectrophotometry, transmission electron microscopy (TEM), a fluorescence spectrometer (PL), and cyclic voltammetry (CV). The fabricated ECL biosensor based on TGA-capped Cd Se QDs is suitable for the detection of glucose concentrations in real human blood samples.

  15. Sensitized chemiluminescence of 2-phenyl-4,5-di(2-furyl)-1H-imidazole/K₃Fe(CN)₆/propyl gallate system combining with solid-phase extraction for the determination of propyl gallate in edible oil.

    Science.gov (United States)

    Kang, Jing; Han, Lu; Chen, Zhonglin; Shen, Jimin; Nan, Jun; Zhang, Yihua

    2014-09-15

    In this paper, a novel chemiluminescence (CL) method has been developed for the determination of propyl gallate (PG). The proposed method was based on the enhancing effect of PG on the CL signal of 2-phenyl-4,5-di(2-furyl)-1H-imidazole (PDFI) and K3Fe(CN)6 reaction in an alkaline solution. Under the optimum conditions, the enhanced CL intensity was linearly related to the concentration of PG. The linear range of the calibration curve was 0.05-8 μg/mL, and the corresponding detection limit (3σ) was 0.036 μg/mL. The relative standard deviation for determining 1.0 μg/mL PG was 2.8% (n=11). The proposed method has been successfully applied to the determination of PG in edible oil. The edible oil samples were prepared by the solid-phase extraction (SPE) with a C18 column served as the stationary phase. Furthermore, the possible CL mechanism was also discussed briefly based on the photoluminescence (PL) and CL spectra. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Characterization of the response chemiluminescence of neutrophils human beings to the hemolysin Escherichia coli alpha

    International Nuclear Information System (INIS)

    Garcia, J.

    2000-01-01

    Escherichia coli alpha hemolysin (AH) evoked a luminol-amplified chemiluminescence (CL) response from human polymorphonuclear leukocytes (PMN). Analysis of kinetic parameters of the PMN CL response to AH established similarities with that of PMN to the calcium ionophore A23187. PMN CL responses to both AH and A23187 were equally decreased by preincubating PMN with A63612, a hidroxamic acid derivative and lipooxigenase inhibitor, showing that the CL response to both hemolysin and ionophore share a common mechanism, probably activation of leukotriene synthesis, due to calcium entry into the cells brought about by AH and A23187. In addition, the CL response of PMN to AH was lowered by the hydroxyl radical scavenger dimethyl sulfoxide, further suggesting arachidonate metabolism is involved in CL response. (Author) [es

  17. Application of a Newly Developed High-Sensitivity HBsAg Chemiluminescent Enzyme Immunoassay for Hepatitis B Patients with HBsAg Seroclearance

    OpenAIRE

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-01-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstr...

  18. Chemiluminescence immunoassay based on dual signal amplification strategy of Au/mesoporous silica and multienzyme functionalized mesoporous silica

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jiehua, E-mail: linjiehua@qust.edu.cn [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China); Zhao Yue; Wei Zhijing; Wang Wei [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China)

    2011-11-15

    Highlights: > The increased amount of monoclonal antibody in Au/SiO{sub 2} led to a wider linear range. > Due to the increased HRP tags in HRP-Ab{sub 2}/SiO{sub 2}, signal amplification achieved. > A simple dual amplification immunoassay achieved with flow injection analysis. - Abstract: A chemiluminescent dual signal amplification strategy for the determination of {alpha}-fetoprotein (AFP) was proposed based on a sandwich immunoassay format. Monoclonal antibody of AFP immobilized on the gold nanoparticles doped mesoporous SiO{sub 2} (Au/SiO{sub 2}) were prepared and used as a primary antibody. Horseradish peroxidase (HRP) and HRP-labeled secondary antibody (Ab{sub 2}) co-immobilized into the mesoporous SiO{sub 2} nanoparticles (HRP-Ab{sub 2}/SiO{sub 2}) were used as the labeled immunological probe. Due to the high ratio surface areas and pore volumes of the mesoporous SiO{sub 2}, not only the amount of AFP monoclonal antibody but also the amount of the modified HRP and Ab{sub 2} in HRP-Ab{sub 2}/SiO{sub 2} were largely increased. Thus the chemiluminescent signal was amplified by using the system of luminol and H{sub 2}O{sub 2} under the catalysis of HRP. Under the optimal conditions, two linear ranges for AFP were obtained from 0.01 to 0.5 ng mL{sup -1} and 0.5 to 100 ng mL{sup -1} with a detection limit of 0.005 ng mL{sup -1} (3{sigma}). The fabricated signal amplification strategy showed an excellent promise for sensitive detection of AFP and other tumor markers.

  19. Usage of liquid scintillation counting for detecting the chemiluminescence of cells and its application in medicine

    International Nuclear Information System (INIS)

    Li Tianxing; Liang Qizhong; Zou Xiaowei; Yang Zhaohen; Huang Yong; Li Huaqiang

    1995-01-01

    The liquid scintillator counting-chemiluminescence (LSC-CL) of mono-photon radiance is a sensitive, handy and high-autoanalytic technique. Through measuring basic CL, dependent CL and maximum phagocytic CL of polymorphonuclear (PMN), we studied best factor levels of the method with orthogonal design [L 9 (3 4 )]. The results showed the peak forms changed markedly (inter-group P -4 M). PMN-CL in blood was measured during acute attack of the old patients with chronic bronchitis and the children with pneumonia bronchial. It was suggested that PMN phagocytosis decreased. So the dynamic analysis of maximum phagocytic CL would help us with the deep going clinical researches of the mechanisms of anti-inflammation and injuring by the oxygen free radicals

  20. Hypericin from St. John’s Wort (hypericum perforatum) as a novel natural fluorophore for chemiluminescence reaction of bis (2,4,6-trichlorophenyl) oxalate–H2O2–imidazole and quenching effect of some natural lipophilic hydrogen peroxide scavengers

    International Nuclear Information System (INIS)

    Kazemi, Sayed Yahya; Abedirad, Seyed Mohammad; Zali, Seyed Hassan; Amiri, Mohadeseh

    2012-01-01

    Hypericin (HYP) molecule is a natural photoactive pigment, which plays a role as an effective photoreceptor in some plants of the Hypericum species (the most common of which is Saint John’s Wort) and some insect species. The present work deals with the first attempt to the study of peroxyoxalate chemiluminescence (POCL) system in the presense of HYP as a natural fluorophore. Reaction of bis (2,4,6-trichlorophenyl) oxalate(TCPO)–H 2 O 2 –imidazole can transfer energy to a HYP via formation of dioxetane through the chemically initiated electron exchange luminescence (CIEEL) mechanism and can emits a very intense red light. The effects of HYP, hydrogen peroxide, TCPO and imidazole concentrations on kinetic chemiluminescence parameters were also studied. These parameters including rise and fall rate constant for the chemiluminescence burst, theoretical and experimental maximum intensity, theoretical and experimental time to reach maximum intensity and total light yield emission were evaluated by using a pooled intermediate model for a non-linear least-squares curve fitting program, KINFIT. Moreover, quenching effect of two lipophilic natural antioxidant, Quercetin and β-carotene on it system was also investigated. The measurable concentration range of 7×10 −6 M to 7.5×10 −5 M of antioxidants were evaluated from the proper Stern–Volmer plots with satisfactory RSD% and corresponding detection limits of 2.2×10 −6 and 3.7×10 −6 for β-carotene and quercetin respectively. - Highlights: ► Red fluorophores may therefore chemiluminescence more intensely than other commonly chemiluminophores and emits light in longer wavelengths. ► Hypericin from St. John’s wort (hypericum perforatum) as natural red fluorophore for peroxyoxalate chemiluminescence was introduced. ► Quenching effect of two antioxidant, quercetin and β-carotene on it system was also investigated. ► The non linear least-squares curve fitting program KINFIT was applied to study of CL

  1. Directly oxidized chemiluminescence of 2-substituted-4,5-di(2-furyl)-1H -imidazole by acidic potassium permanganate and its analytical application for determination of albumin.

    Science.gov (United States)

    Kang, Jing; Zhang, Yumin; Huang, Zhongxiu; Han, Lu; Tang, Jieli; Wang, Shuaijun; Zhang, Yihua

    2011-07-01

    In the paper, 2,4,5-tri(2-furyl)-1H-imidazole (TFI) and 2-phenyl-4,5-di(2-furyl)-1H-imidazole (PDFI), were chosen to investigate chemiluminescence (CL) properties of 2-substituted-4,5-di(2-furyl)-1H-imidazoles. The directly oxidized CL of analytes by potassium permanganate (KMnO(4)) was in detail studied. The KMnO(4) could directly oxidize TFI/PDFI to produce strong CL emission in acidic solution. The effects of experimental conditions were investigated. Under the optimal conditions, the effect of albumin on the TFI/PDFI-KMnO(4) system was investigated. It was found that the addition of albumin into the system could induce enhancement of CL signal, and the enhanced CL intensity is linearly related to the logarithm of concentration of albumin. Based on this study, a novel CL method has been developed for the determination of albumin with high sensitivity and good selectivity. The method was applied to the determination of albumin in human serum samples, and the results were in agreement with those obtained by the bromcresol green (BCG) method. The relative errors for the analytical results were from -5.8% to 4.2%. These new phenomena would further enable people to exploit more CL analytical application of the heterocyclic imidazole derivatives. © Springer Science+Business Media, LLC 2011

  2. Rapid immuno-analytical system physically integrated with lens-free CMOS image sensor for food-borne pathogens.

    Science.gov (United States)

    Jeon, Jin-Woo; Kim, Jee-Hyun; Lee, Jong-Mook; Lee, Won-Ho; Lee, Do-Young; Paek, Se-Hwan

    2014-02-15

    To realize an inexpensive, pocket-sized immunosensor system, a rapid test devise based on cross-flow immuno-chromatography was physically combined with a lens-free CMOS image sensor (CIS), which was then applied to the detection of the food-borne pathogen, Salmonella typhimurium (S. typhimurium). Two CISs, each retaining 1.3 mega pixel array, were mounted on a printed circuit board to fabricate a disposable sensing module, being connectable with a signal detection system. For the bacterial analysis, a cellulose membrane-based immunosensing platform, ELISA-on-a-chip (EOC), was employed, being integrated with the CIS module, and the antigen-antibody reaction sites were aligned with the respective sensor. In such sensor construction, the chemiluminescent signals produced from the EOC are transferred directly into the sensors and are converted to electric signals on the detector. The EOC-CIS integrated sensor was capable of detecting a traceable amount of the bacterium (4.22 × 10(3)CFU/mL), nearly comparable to that adopting a sophisticated detector such as cooled-charge-coupled device, while having greatly reduced dimensions and cost. Upon coupling with immuno-magnetic separation, the sensor showed an additional 67-fold enhancement in the detection limit. Furthermore, a real sample test was carried out for fish muscles inoculated with a sample of 3.3CFU S. typhimurium per 10 g, which was able to be detected earlier than 6h after the onset of pre-enrichment by culture. © 2013 Elsevier B.V. All rights reserved.

  3. The investigation of photo-induced chemiluminescence on Co2+-doped TiO2 nanoparticles and its analytical application.

    Science.gov (United States)

    Li, Guixin; Nan, Hongyan; Zheng, Xingwang

    2009-07-01

    A novel space- and time-resolved photo-induced chemiluminescence (PICL) analytical method was developed based on the photocatalysis of the Co2+-doped TiO2 nanoparticles. The PICL reaction procedure under the photocatalysis of Co2+-doped TiO2 nanoparticles was investigated using cyclic voltammetry and potentiometry. Meanwhile, the effect of the electrical double layer outside the Co2+-doped TiO2 nanoparticles on the PICL was investigated by contrasting with the Co2+-doped TiO2-SiO2 core-shell nanoparticles. Significantly, the CL intensity increased apparently and the time of the CL was prolonged in the presence of procaterol hydrochloride because the mechanism of the enhanced PICL reaction may be modified. The route of the PICL was changed due to the participation of the procaterol hydrochloride enriched at the surface of the Co2+-doped TiO2-SiO2 in the PICL reaction, which prolonged the time of the CL reaction and resulted in the long-term PICL. The analytical characteristics of the proposed in-situ PICL method were investigated using the procaterol hydrochloride as the model analyte. The investigation results showed that this new PICL analytical method offered higher sensitivity to the analysis of the procaterol hydrochloride and the PICL intensity was linear with the concentration of the procaterol hydrochloride in the range from ca. 2.0 x 10(-10) to 1.0 x 10(-8) g mL(-1).

  4. An electrochemical ELISA-like immunosensor for miRNAs detection based on screen-printed gold electrodes modified with reduced graphene oxide and carbon nanotubes.

    Science.gov (United States)

    Tran, H V; Piro, B; Reisberg, S; Huy Nguyen, L; Dung Nguyen, T; Duc, H T; Pham, M C

    2014-12-15

    We design an electrochemical immunosensor for miRNA detection, based on screen-printed gold electrodes modified with reduced graphene oxide and carbon nanotubes. An original immunological approach is followed, using antibodies directed to DNA.RNA hybrids. An electrochemical ELISA-like amplification strategy was set up using a secondary antibody conjugated to horseradish peroxidase (HRP). Hydroquinone is oxidized into benzoquinone by the HRP/H2O2 catalytic system. In turn, benzoquinone is electroreduced into hydroquinone at the electrode. The catalytic reduction current is related to HRP amount immobilized on the surface, which itself is related to miRNA.DNA surface density on the electrode. This architecture, compared to classical optical detection, lowers the detection limit down to 10 fM. Two miRNAs were studied: miR-141 (a prostate biomarker) and miR-29b-1 (a lung cancer biomarker). Copyright © 2014 Elsevier B.V. All rights reserved.

  5. [The criterion prognostic significance of examinations of chemiluminescence of oral fluid under impact of chemical pollutants of manufacture of rubber and rubber technical production].

    Science.gov (United States)

    Galiullina, E F; Valiev, A v; Kamilov, R F; Shakirov, D F; Buliakov, P T

    2013-12-01

    The article presents the results of studies concerning the effect of unfavorable factors of chemical nature on fluid of oral cavity among workers of the Ufa plant of elastomer materials, articles and structures. It is established that in persons contacting with chemical pollutants of manufacture of rubber and rubber technical production the indicators of chemiluminescence of saliva fluid are significantly expressed and depend on professional standing.

  6. Novel assay of antibacterial components in manuka honey using lucigenin-chemiluminescence-HPLC

    International Nuclear Information System (INIS)

    Karasawa, Koji; Haraya, Shiomi; Okubo, Sachie; Arakawa, Hidetoshi

    2017-01-01

    Five components (hydrogen peroxide, methylglyoxal, dihydroxyacetone, fructose and glucose) of New Zealand manuka honey (Leptospermum scoparium) were analyzed using lucigenin chemiluminescence high-performance liquid chromatography (lucigenin-CL-HPLC). We focused on active oxygen species produced from the components in order to easily detect these five components contained in manuka honey. H_2O_2 and O_2"− generated from these components were identified by lucigenin-CL and electron spin resonance (ESR), and the bactericidal effect of ROS was confirmed using E. coli. The previously reported assays for Manuka honey components have low specificities and require complicated preprocessing methods. As our results, the detection and identification of these components were possible within 30 min in lucigenin-CL-HPLC system, without any special treatment. It is considered that lucigenin-CL-HPLC is useful for the quality control and the analysis of various honey. - Highlights: • Antibacterial components in manuka honey by HPLC with lucigenin-CL. • Five antibacterial compounds measured via generation of reactive oxygen species. • Simple, sensitive and useful for quality control and analysis of antibacterial honey.

  7. Electrochemistry and electrogenerated chemiluminescence of films of silicon nanoparticles in aqueous solution

    International Nuclear Information System (INIS)

    Bae, Yoonjung; Lee, Doh C; Rhogojina, Elena V; Jurbergs, David C; Korgel, Brian A; Bard, Allen J

    2006-01-01

    Films of octadecyl-capped Si nanoparticles (NPs) (diameter, 3.4 ± 0.7 nm) prepared by drop-coating on indium tin oxide (ITO) showed electrogenerated chemiluminescence (ECL) for both cathodic and anodic potential sweeps in KOH solutions containing peroxydisulfate. The redox potentials of the Si NPs can be estimated as approximately -0.9 and +0.95 V (versus Ag|AgCl) based on the anodic potential for the onset of ECL minus the ECL peak energy. The ECL exhibits a relatively broad spectrum (FWHM = 160 nm) with a peak wavelength of ∼670 nm (1.85 eV), similar to the photoluminescence spectra. In electrochemical studies in KOH solution in the absence of peroxydisulfate, an anodic current peak appears at about -1 V (versus Ag|AgCl) following a scan to negative potentials. A similar peak has been observed during the etching of a bulk single crystal Si electrode in alkaline aqueous solution. Unpassivated surface sites of Si NPs seem to be etched at potentials negative of the anodic oxidation peak

  8. Prospective validation of an automated chemiluminescence-based assay of renin and aldosterone for the work-up of arterial hypertension.

    Science.gov (United States)

    Rossi, Gian Paolo; Ceolotto, Giulio; Rossitto, Giacomo; Seccia, Teresa Maria; Maiolino, Giuseppe; Berton, Chiara; Basso, Daniela; Plebani, Mario

    2016-09-01

    The availability of simple and accurate assays of plasma active renin (DRC) and aldosterone concentration (PAC) can improve the detection of secondary forms of arterial hypertension. Thus, we investigated the performance of an automated chemiluminescent assay for DRC and PAC in referred hypertensive patients. We prospectively recruited 260 consecutive hypertensive patients referred to an ESH Center for Hypertension. After exclusion of six protocol violations, 254 patients were analyzed: 67.3% had primary hypertension, 17.3% an aldosterone producing adenoma (APA), 11.4% idiopathic hyperaldosteronism (IHA), 2.4% renovascular hypertension (RVH), 0.8% familial hyperaldosteronism type 1 (FH-1), 0.4% apparent mineralocorticoid excess (AME), 0.4% a renin-producing tumor, and 3.9% were adrenalectomized APA patients. Bland-Altman plots and Deming regression were used to analyze results. The diagnostic accuracy (area under the curve, AUC of the ROC) of the DRC-based aldosterone-renin ratio (ARRCL) was compared with that of the PRA-based ARR (ARRRIA) using as reference the conclusive diagnosis of APA. At Bland-Altman plot, the DRC and PAC assay showed no bias as compared to the PRA and PAC assay. A tight relation was found between the DRC and the PRA values (concordance correlation coefficient=0.92, pAPA identification the AUC of the ARRCL was higher than that of the ARRRIA [0.974 (95% CI 0.940-0.991) vs. 0.894 (95% CI 0.841-0.933), p=0.02]. This rapid automated chemiluminescent DRC/PAC assay performed better than validated PRA/PAC radioimmunoassays for the identification of APA in referred hypertensive patients.

  9. An ultrasensitive chemiluminescence immunoassay for fumonisin B1 detection in cereals based on gold-coated magnetic nanoparticles.

    Science.gov (United States)

    Jie, Mingsha; Yu, Songcheng; Yu, Fei; Liu, Lie; He, Leiliang; Li, Yanqiang; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B; Wu, Yongjun

    2018-07-01

    In the present study, a novel highly sensitive magnetic enzyme chemiluminescence immunoassay (MECLIA) was developed to detect fumonisin B 1 (FB 1 ) in cereal samples. The gold-coated magnetic nanoparticles (Fe 3 O 4 @Au, GoldMag) were used as solid phase carrier to develop a competitive CLIA for detecting FB 1 , in which FB 1 in samples would compete with FB 1 -ovalbumin coated on the surface of Fe 3 O 4 @Au nanoparticles for binding with FB 1 antibodies. Successively, horseradish peroxidase labeled goat anti-rabbit IgG (HRP-IgG) was conjugated with FB 1 antibodies on the microplate. In substrate solution containing luminol and H 2 O 2 , HRP-IgG catalyzed luminol oxidation by H 2 O 2 , generating a high chemiluminescence signal. The FB 1 immune GoldMag particles were characterized by Fourier transform infrared spectroscopy, scanning electron microscope and zeta potential analysis, etc. RESULTS: The concentrations and the reaction times of these immunoreagents were optimized to improve the performances of this method. The established method could detect as low as 0.027 ng mL -1 FB 1 from 0.05 ng mL -1 to 25 ng mL -1 , demonstrating little cross-reaction (less than 2.4%) with other structurally related compounds. The average intrassay relative SD (RSD) (n = 6) was 3.4% and the average interassay RSD (n = 6) was 5.4%. This method was successfully applied for the determination of FB 1 in corn and wheat and gave recoveries of between 98-110% and 91-105%, respectively. The results of the present study suggest that the MECLIA approach has potential application for high-throughput fumonisin screening in cereals. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  10. Electrochemiluminescence immunosensor for ultrasensitive detection of biomarker using Ru(bpy)(3)(2+)-encapsulated silica nanosphere labels.

    Science.gov (United States)

    Qian, Jing; Zhou, Zhenxian; Cao, Xiaodong; Liu, Songqin

    2010-04-14

    Here, we describe a new approach for electrochemiluminescence (ECL) assay with Ru(bpy)(3)(2+)-encapsulated silica nanoparticle (SiO(2)@Ru) as labels. A water-in-oil (W/O) microemulsion method was employed for one-pot synthesis of SiO(2)@Ru nanoparticles. The as-synthesized SiO(2)@Ru nanoparticles have a narrow size distribution, which allows reproducible loading of Ru(bpy)(3)(2+) inside the silica shell and of alpha-fetoprotein antibody (anti-AFP), a model antibody, on the silica surface with glutaraldehyde as linkage. The silica shell effectively prevents leakage of Ru(bpy)(3)(2+) into the aqueous solution due to strong electrostatic interaction between the positively charged Ru(bpy)(3)(2+) and the negatively charged surface of silica. The porous structure of silica shell allowed the ion to move easily through the pore to exchange energy/electrons with the entrapped Ru(bpy)(3)(2+). The as-synthesized SiO(2)@Ru can be used as a label for ultrasensitive detection of biomarkers through a sandwiched immunoassay process. The calibration range of AFP concentration was 0.05-30 ng mL(-1) with linear relation from 0.05 to 20 ng mL(-1) and a detection limit of 0.035 ng mL(-1) at 3sigma. The resulting immunosensors possess high sensitivity and good analytical performance. Copyright 2010 Elsevier B.V. All rights reserved.

  11. Ultrasensitive electrochemical biosensor based on the oligonucleotide self-assembled monolayer-mediated immunosensing interface

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Dengyou; Luo, Qimei [Science College of Hunan Agricultural University, Changsha 410128 (China); Deng, Fawen [The Fourth Hospital of Chansha, Changsha 410006 (China); Li, Zhen [Science College of Hunan Agricultural University, Changsha 410128 (China); Li, Benxiang, E-mail: 172170960@qq.com [Science College of Hunan Agricultural University, Changsha 410128 (China); Shen, Zhifa, E-mail: shenzhifa@wmu.edu.cn [Key Laboratory of Laboratory Medicine, Ministry of Education, Zhejiang Provincial Key Laboratory of Medical Genetics, College of Laboratory Medicine and Life Sciences, Wenzhou Medical University, Wenzhou 325035 (China)

    2017-06-08

    Highly sensitive and selective quantitation of a variety of proteins over a wide concentration range is highly desirable for increased accuracy of biomarker detection or for multidisease diagnostics. In the present contribution, using human immunoglobulin G (HIgG) as the model target protein, an electrochemical ultrasensitive immunosensing platform was developed based on the oligonucleotide self-assembled monolayer-mediated (OSAM) sensing interface. For this immunosensor, the “signal-on” signaling mechanism and enzymatic signal amplification effect were integrated into one sensing architecture. Moreover, the thiolated flexible single-stranded DNAs immobilized onto gold electrode surface not only performs the wobbling motion to facilitate the electron transfer between the electrode surface and biosensing layer but also fundamentally prohibiting the direct interaction of proteins with gold substrate. Thus, the electrochemical signal could be efficiently enhanced and the unspecific adsorption or cross-reaction might be eliminated. As a result, utilizing the newly-proposed immunosensor, the HIgG can be detected down to 0.5 ng/mL, and the high detection specificity is offered. The successful design of OSAM and the highly desirable detection capability of new immunosensor are expected to provide a perspective for fabricating new robust immunosensing platform and for promising potential of oligonucleotide probe in biological research and biomedical diagnosis. - Highlights: • An electrochemical ultrasensitive immunosensing platform was developed based on the oligonucleotide self-assembled monolayer (OASM). • OASM severs as a flexible monolayer to promote electron transfer and prohibits the direct interaction of proteins with gold substrate. • The electrochemical signal is efficiently enhanced and the unspecific adsorption or cross-reaction is eliminated. • Target protein can be detected down to 0.5 ng/mL, and the high detection specificity can be obtained.

  12. Development of a method for the characterization of the oxidation stability of domestic heating oil and domestic heating oil with alternative components using chemiluminescence; Entwicklung einer Analysemethode zur Charakterisierung der Oxidationsstabilitaet von Heizoel EL und Heizoel EL A mittels Chemilumineszenz

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Winfried; Lukito, Jayadi; Schloss, Heide vom [Oel-Waerme-Institut gGmbH (OWI), Aachen-Herzogenrath (Germany)

    2013-04-15

    The project's aim was to develop a process that serves to determine the oxidation stability of heating oil - FAME-/ heating oil - vegetable oil-blends clearly. Due to a directed energy input by means of the process of chemiluminescence, statements about the storage stability and the thermal stability of blends can be made. During the process the ageing of blend components and of the heating oil are taken into consideration. As a result, ageing processes and products of pure heating oil as well as biogenic components can be determined. It was shown that the process is applicable to blends up to an admixture of at least 20 % (V/V) of biogenic components, whereby blends with higher admixture shares can be analyzed as well. According to DIN SPEC 51603 - 6 'Heating Oil Alternative' the admixture of FAME is limited to 20 %(V/V) and the admixture of vegetable oil to 5 % (V/V) because of the distillation range. On the basis of these investigations it could be shown how oxidation products influence the signal process of the chemiluminescence radiation and how they can be correlated by a measurable physical value. Moreover, a new evaluation criterion has been developed. By means of this criterion a good reproducibility - regarding the determination of the oxidation stability according to the chemiluminescence methodology for non-aged fuels - can be achieved. The fuel characteristic decrease in the stability of the tested fuels can be represented only partially by the chemiluminescence process, as the measured values are subject to fluctuations. (orig.)

  13. Real time imaging of live cell ATP leaking or release events by chemiluminescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yun [Iowa State Univ., Ames, IA (United States)

    2008-12-18

    The purpose of this research was to expand the chemiluminescence microscopy applications in live bacterial/mammalian cell imaging and to improve the detection sensitivity for ATP leaking or release events. We first demonstrated that chemiluminescence (CL) imaging can be used to interrogate single bacterial cells. While using a luminometer allows detecting ATP from cell lysate extracted from at least 10 bacterial cells, all previous cell CL detection never reached this sensitivity of single bacteria level. We approached this goal with a different strategy from before: instead of breaking bacterial cell membrane and trying to capture the transiently diluted ATP with the firefly luciferase CL assay, we introduced the firefly luciferase enzyme into bacteria using the modern genetic techniques and placed the CL reaction substrate D-luciferin outside the cells. By damaging the cell membrane with various antibacterial drugs including antibiotics such as Penicillins and bacteriophages, the D-luciferin molecules diffused inside the cell and initiated the reaction that produces CL light. As firefly luciferases are large protein molecules which are retained within the cells before the total rupture and intracellular ATP concentration is high at the millmolar level, the CL reaction of firefly luciferase, ATP and D-luciferin can be kept for a relatively long time within the cells acting as a reaction container to generate enough photons for detection by the extremely sensitive intensified charge coupled device (ICCD) camera. The result was inspiring as various single bacterium lysis and leakage events were monitored with 10-s temporal resolution movies. We also found a new way of enhancing diffusion D-luciferin into cells by dehydrating the bacteria. Then we started with this novel single bacterial CL imaging technique, and applied it for quantifying gene expression levels from individual bacterial cells. Previous published result in single cell gene expression quantification

  14. Chemiluminescence measurement of cinnamon-, curry-, red pepper- and milk powder as a method to identify ionizing radiation treatment. Die Messung der Chemilumineszenz von Zimt-, Curry-, Paprika- und Milchpulver als Nachweis einer Behandlung mit ionisierenden Strahlen

    Energy Technology Data Exchange (ETDEWEB)

    Boegl, W; Heide, L

    1983-11-01

    The findings may be summarized as follows: significant differences in the dose response relationship of the different foodstuffs were found; the chemiluminescence intensity of different foodstuffs irradiated at equal dose levels may vary considerably; in some cases there might be evidence of radiation treatment even 2 months afterwards; after heating, the irradiated foodstuffs showed reduced chemiluminescence intensity. In some cases it is, however, possible to identify previous irradiation of a foodstuff; if irradiated foodstuffs are treated with water vapor, the radicals will react with the water so as to preclude the identification of previous irradiation; UV-irradiation will result in a drastic increase in luminescence intensity, at least in some cases and air oxidation may also increase the luminescence intensity, especially in fatty foodstuffs.

  15. Extra-weak chemiluminescence produced by autoxidation of kampo extract preparations stored in heat-stressed conditions.

    Science.gov (United States)

    Sato, H; Hirayama, H; Yamamoto, T; Ishizawa, F; Mizugaki, M

    1998-06-01

    The purpose of this study was to evaluate the usefulness of extra-weak chemiluminescence (CL) measurement as a rapid method to estimate the stability of Kampo extract preparations. It was found that the Kampo drugs that emit little CL were stable, while those with higher CL were comparatively unstable with regard to the various stability markers, including change of coloration (browning), contents of specific ingredients, high molecular compounds, amino acids and sugars under various conditions of heat storage. Excellent correlation existed between the CL of Kampo drugs and the coloration (delta E* (ab)) and the other above-mentioned evaluation markers. From this investigation, it was deduced that the CL of Kampo drugs originates in the early stage of the Maillard reaction and reflects the stability of the preparations, and that CL is useful for estimating the stability of Kampo drugs.

  16. Applications of capillary electrophoresis with chemiluminescence detection in clinical, environmental and food analysis. A review

    International Nuclear Information System (INIS)

    Lara, Francisco J.; Airado-Rodríguez, Diego; Moreno-González, David; Huertas-Pérez, José F.; García-Campaña, Ana M.

    2016-01-01

    This paper reviews the latest developments and analytical applications of chemiluminescence detection coupled to capillary electrophoresis (CE-CL). Different sections considering the most common CL systems have been included, such as the tris(2,2′-bipyridine)ruthenium(II) system, the luminol and acridinium derivative reactions, the peroxyoxalate CL or direct oxidations. Improvements in instrumental designs, new strategies for improving both resolution and sensitivity, and applications in different fields such as clinical, pharmaceutical, environmental and food analysis have been included. This review covers the literature from 2010 to 2015. - Highlights: • An up-to-date critical review about the evolution of CE-CL is presented. • Tris(2,2′-bipyridine)ruthenium(II) and luminol as the most used CL systems. • Instrumental designs and strategies for improving resolution and sensitivity. • Applications in clinical, pharmaceutical, environmental and food analysis.

  17. Novel and versatile solid-state chemiluminescence sensor based on TiO2-Ru(bpy)32+ nanoparticles for pharmaceutical drugs detection

    Science.gov (United States)

    Al-Hetlani, Entesar; Amin, Mohamed O.; Madkour, Metwally

    2018-02-01

    This work describes a novel and versatile solid-state chemiluminescence sensor for analyte detection using TiO2-Ru(bpy)32+-Ce(IV). Herein, we report the synthesis, characterization, optimization and application of a new type of hybrid nanoparticles (NPs). Mesoporous TiO2-Ru(bpy)32+ NPs were prepared using a modified sol-gel method by incorporating Ru(bpy)32+ into the initial reaction mixture at various concentrations. The resultant bright orange precipitate was characterized via transmission electron microscopy, N2 sorpometry, inductively coupled plasma-optical emission spectrometer (ICP-OES), Raman and UV-Vis spectroscopy techniques. The concentration of Ru(bpy)32+ complex in the NPs was quantified using ICP-OES, and its chemiluminescence (CL) response was measured and compared with the same concentration in the liquid phase using oxalate as model analyte. The results showed that this type of hybrid material exhibited a higher CL signal compared with the liquid phase due to the enlarged surface area of the hybrid NPs ( 149.6 m2/g). The amount of TiO2-Ru(bpy)32+ NPs and the effect of the analyte flow rate were also investigated to optimize the CL signal. The optimized system was further used to detect oxalate and two pharmaceutical drugs, namely, imipramine and promazine. The linear range for both drugs was 1-100 pm with limits of detection (LOD) of 0.1 and 0.5 pm, respectively. This approach is considered to be simple, low cost and facile and can be applied to a wide range of analytes.

  18. Novel and versatile solid-state chemiluminescence sensor based on TiO2-Ru(bpy32+ nanoparticles for pharmaceutical drugs detection

    Directory of Open Access Journals (Sweden)

    Al-Hetlani Entesar

    2018-02-01

    Full Text Available This work describes a novel and versatile solid-state chemiluminescence sensor for analyte detection using TiO2-Ru(bpy32+-Ce(IV. Herein, we report the synthesis, characterization, optimization and application of a new type of hybrid nanoparticles (NPs. Mesoporous TiO2-Ru(bpy32+ NPs were prepared using a modified sol-gel method by incorporating Ru(bpy32+ into the initial reaction mixture at various concentrations. The resultant bright orange precipitate was characterized via transmission electron microscopy, N2 sorpometry, inductively coupled plasma-optical emission spectrometer (ICP-OES, Raman and UV-Vis spectroscopy techniques. The concentration of Ru(bpy32+ complex in the NPs was quantified using ICP-OES, and its chemiluminescence (CL response was measured and compared with the same concentration in the liquid phase using oxalate as model analyte. The results showed that this type of hybrid material exhibited a higher CL signal compared with the liquid phase due to the enlarged surface area of the hybrid NPs (~149.6 m2/g. The amount of TiO2-Ru(bpy32+ NPs and the effect of the analyte flow rate were also investigated to optimize the CL signal. The optimized system was further used to detect oxalate and two pharmaceutical drugs, namely, imipramine and promazine. The linear range for both drugs was 1–100 pm with limits of detection (LOD of 0.1 and 0.5 pm, respectively. This approach is considered to be simple, low cost and facile and can be applied to a wide range of analytes.

  19. Potassium permanganate-glutaraldehyde chemiluminescence system catalyzed by gold nanoprisms toward selective determination of fluoride.

    Science.gov (United States)

    Abolhasani, Jafar; Hassanzadeh, Javad; Ghorbani-Kalhor, Ebrahim

    2016-02-01

    Gold and silver nanoparticles (NPs) are shown to exert a positive effect on the chemiluminescence (CL) reaction of permanganate aldehydes. Interestingly, between various shapes examined, Au nanoprisms have the highest beneficial effect. This effect is even more notable in the presence of sodium dodecyl sulfate (SDS) surfactant. UV-vis spectra and transmission electron microscopy were used to characterize the NP shapes and sizes. Furthermore, it was observed that iron(III) ions can slightly increase CL emission of this system. This intensification is very effective in the presence of fluoride ions (F(-)). These observations form the basis of the method for the high sensitive determination of F(-) in the 6-1200 nmol L(-1) concentration range, with a detection limit of 2.1 nmol L(-1). The proposed method has good precision and was satisfactorily used in the selective determination of low concentrations of fluoride ion in real samples. Copyright © 2015 John Wiley & Sons, Ltd.

  20. New method for monitoring nitric oxide in vivo using microdialysis sampling and chemiluminescence reaction

    Science.gov (United States)

    Yao, Dachun; Evmiridis, Nick P.; Zhou, Yikai; Xu, Shunqing; Zhou, Huarong

    2001-09-01

    A new method employing a combination of micro dialysis sampling and chemiluminescence reaction was developed to monitor nitric oxide (NO) in vivo. A special probe was designed with an interference-free membrane to achieve a very high selectivity for NO. High sensitivity was achieved by optimizing the working system and improving the NO sampling time. This system was used in vivo to monitor blood and brain tissue in rats and rabbits. We have established that this system is sensitive enough to detect variations in NO production in difference physiological state. The system can detect NO in the linear range of 5nM-1(mu) M, with a detection limit of 1nM, and real NO concentrations in our experimental animals were found to be in the range of 1-5 nM or even less. Finally, the effects of body temperature, NO donors, Viagra, NO activators, NO cofactors, NO interference were investigated carefully in different physiological situations.

  1. Application of chemiluminescence to the study of alpha, beta and gamma radiolysis of water

    International Nuclear Information System (INIS)

    Broudic, V.; Muzeau, B.; Jegou, C.; Bonnal, M.; Gavazzi, A.; Marques, C.

    2004-01-01

    In the frame of the French research program on the long-term behavior of spent nuclear fuel, experiments are conducted in ATALANTE to develop and validate models of spent fuel evolution in contact with an aqueous phase. One of the mechanisms that may govern intermediate or long-term alteration of the spent fuel matrix in a repository is the oxidizing dissolution by radiolysis products of water. Leaching experiments in de-aerated media requires the analysis of hydrogen peroxide, as a major product of water radiolysis, down to 10 -8 mol.L -1 . This work presents the results obtained using the chemiluminescence reaction of iso-luminol with H 2 O 2 , catalyzed by micro-peroxidase. Depending on the samples used, different types of radiolytic processes were studied: α radiolysis of water when leaching UO 2 pellets doped with alpha emitters, or γ radiolysis of water when leaching the same samples or spent fuel in a gamma field. Influences of operating conditions on the analytical results are discussed. (authors)

  2. Dual-peak electrogenerated chemiluminescence of carbon dots for iron ions detection.

    Science.gov (United States)

    Zhang, Pengjia; Xue, Zhenjie; Luo, Dan; Yu, Wei; Guo, Zhihui; Wang, Tie

    2014-06-17

    Carbon dots (CDs) have rigorously been investigated on their unique fluorescent properties but rarely their electrogenerated chemiluminescence (ECL) behavior. We are here to report a dual-peak ECL system of CDs, one at -2.84 V (ECL-1) and the other at -1.71 V (ECL-2) during the cyclic sweep between -3.0 and 3.0 V at scan rate of 0.2 V s(-1) in 0.1 M tetrabutyl ammonium bromide (TBAB) ethanol solution, which is more efficiency to distinguish metallic ions than single-peak ECL. The electron transfer reaction between individual electrochemically reduced nanocrystal species and coreactants led to ECL-1, in which the electron injected to the conduction band of CDs in the cathodic process. Ion annihilation reactions induced direct formation of exciplexes that produced another ECL signal, ECL-2. ECL-1 showed higher sensitivity to the surrounding environment than ECL-2 and thus was used for ECL detection of metallic ions. Herein, we can serve as an internal standard method to detect iron ions. A linear relationship of the intensity ratio R of ECL-1 and ECL-2 to iron ions was observed in the concentration extending from 5 × 10(-6) to 8 × 10(-5) M with a detection limit of 7 × 10(-7) M.

  3. Automated 3D-Printed Unibody Immunoarray for Chemiluminescence Detection of Cancer Biomarker Proteins

    Science.gov (United States)

    Tang, C. K.; Vaze, A.; Rusling, J. F.

    2017-01-01

    A low cost three-dimensional (3D) printed clear plastic microfluidic device was fabricated for fast, low cost automated protein detection. The unibody device features three reagent reservoirs, an efficient 3D network for passive mixing, and an optically transparent detection chamber housing a glass capture antibody array for measuring chemiluminescence output with a CCD camera. Sandwich type assays were built onto the glass arrays using a multi-labeled detection antibody-polyHRP (HRP = horseradish peroxidase). Total assay time was ~30 min in a complete automated assay employing a programmable syringe pump so that the protocol required minimal operator intervention. The device was used for multiplexed detection of prostate cancer biomarker proteins prostate specific antigen (PSA) and platelet factor 4 (PF-4). Detection limits of 0.5 pg mL−1 were achieved for these proteins in diluted serum with log dynamic ranges of four orders of magnitude. Good accuracy vs ELISA was validated by analyzing human serum samples. This prototype device holds good promise for further development as a point-of-care cancer diagnostics tool. PMID:28067370

  4. Optical fiber chemiluminescence sensor for iron (II) ion based on immobilized luminol

    International Nuclear Information System (INIS)

    Alipao, Arthur A.; Sevilla, Fortunato III.

    1999-01-01

    A chemiluminescence (CL) sensor for iron (II) was developed based on the catalytic action of the analyte on the CL reaction between luminol and oxygen. The reagents were immobilized on a cellulose membrane and set on a reaction cell which was coupled by means of an optical fiber to a spectrofluorometer. The concentration of iron(II) was quantified by measuring the intensity of the light generated from the CL reaction. The response of the sensor system was rapid and highly reproducible. Good sensitivity was displayed by the sensor system over the five orders of magnitude of iron(II) ion concentration. The calibration curve consisted of two portions: (1) a linear range at lower concentrations (7.5 x 10 -7 M to 1.0 x 10 -4 M) exhibiting a positive slope arising from a catalytic action, and (2) a linear range at higher concentrations (5.0 x 10 -2 M to 2.5 x 10 -4 M) wherein the slope is negative due to an inhibitory action of iron(II) on the CL reaction. The sensor system was highly selective for iron(II) ions. (Author)

  5. Novel assay of antibacterial components in manuka honey using lucigenin-chemiluminescence-HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Karasawa, Koji, E-mail: koji180@pharm.showa-u.ac.jp; Haraya, Shiomi; Okubo, Sachie; Arakawa, Hidetoshi

    2017-02-15

    Five components (hydrogen peroxide, methylglyoxal, dihydroxyacetone, fructose and glucose) of New Zealand manuka honey (Leptospermum scoparium) were analyzed using lucigenin chemiluminescence high-performance liquid chromatography (lucigenin-CL-HPLC). We focused on active oxygen species produced from the components in order to easily detect these five components contained in manuka honey. H{sub 2}O{sub 2} and O{sub 2}{sup −} generated from these components were identified by lucigenin-CL and electron spin resonance (ESR), and the bactericidal effect of ROS was confirmed using E. coli. The previously reported assays for Manuka honey components have low specificities and require complicated preprocessing methods. As our results, the detection and identification of these components were possible within 30 min in lucigenin-CL-HPLC system, without any special treatment. It is considered that lucigenin-CL-HPLC is useful for the quality control and the analysis of various honey. - Highlights: • Antibacterial components in manuka honey by HPLC with lucigenin-CL. • Five antibacterial compounds measured via generation of reactive oxygen species. • Simple, sensitive and useful for quality control and analysis of antibacterial honey.

  6. A signal-on electrogenerated chemiluminescent biosensor for lead ion based on DNAzyme

    International Nuclear Information System (INIS)

    Ma Fen; Sun Bo; Qi Honglan; Zhang Hongge; Gao Qiang; Zhang Chengxiao

    2011-01-01

    A highly reproducible and sensitive signal-on electrogenerated chemiluminescence (ECL) biosensor based on the DNAzyme for the determination of lead ion was developed. The ECL biosensor was fabricated by covalently coupling 5'-amino-DNAzyme-tagged with ruthenium bis (2,2'-bipyridine) (2,2'-bipyridine-4,4'-dicarboxylic acid)-ethylenediamine (Ru1-17E') onto the surface of graphite electrode modified with 4-aminobenzoic acid, and then a DNA substrate with a ribonucleotide adenosine hybridized with Ru1-17E' on the electrode. Upon binding of Pb 2+ to the Ru1-17E' to form a complex which catalyzed the cleavage of the DNA substrate, the double-stranded DNA was dissociated and thus led to a high ECL signal. The signal linearly increases with the concentration of Pb 2+ in the range from 5.0 to 80 pM with a detection limit of 1.4 pM and a relative standard derivation of 2.3%. This work demonstrates that using DNAzyme tagged with ruthenium complex as an ECL probe and covalently coupling method for the fabrication of the ECL biosensor with high sensitivity, good stability and significant regeneration ability is promising approach.

  7. All-in-one bioprobe devised with hierarchical-ordered magnetic NiCo2O4 superstructure for ultrasensitive dual-readout immunosensor for logic diagnosis of tumor marker.

    Science.gov (United States)

    Dai, Hong; Gong, Lingshan; Zhang, Shupei; Xu, Guifang; Li, Yilin; Hong, Zhensheng; Lin, Yanyu

    2016-03-15

    A new enzyme-free all-in-one bioprobe, consisted of hematin decorated magnetic NiCo2O4 superstructure (ATS-MNS-Hb), was designed for ultrasensitive photoelectrochemical and electrochemical dual-readout immunosensing of carcinoembryonic antigen (CEA) on carbon nanohorns (CNH) support. Herein, the MNS, possessed hierarchical-ordered structure, good porosity and magnetism, acted as nanocarrier to absorb abundant Hb molecular after functionalization, providing a convenient collection means by magnetic control as well as enhanced dual-readout sensing performances. CNH superstructures were employed as support to immobilize abounding captured antibodies, and then as-designed dual mode bioprobe, covalent binding with secondary antibody of CEA, was introduced for ultrasensitive detection of CEA by sandwich immunosensing. Photoelectrochemical response originated from plentiful hematin molecular, a excellent photosensitizer with good visible light harvesting efficiency, absorbed by functionalized porous MNS. The resultant concentration dependant linear calibration range was from 10 fg/mL to 1 ng/mL with ultralow detection limit of 10 fg/mL. For electrochemical process, catalase-like property of MNS was validated, moreover, MNS-Hb hybrid exhibited much higher mimic enzyme catalytic activity and evidently amplified electrocatalytic signal, performing a wide dynamic linear range from 1 ng/mL to 40 ng/mL with low detection limit of 1 ng/mL. Additionally, due to the improved accuracy of dual signals detection, the exact diagnoses of serum samples were gotten by operating resulting dual signals with AND logic system. This work demonstrated the promising application of MNS in developing ultrasensitive, cost-effective and environment friendly dual-readout immunosensor and accurate diagnoses strategy for tumor markers. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The alpha hemolysin of Escherichia Coli power the metabolism oxidative of neutrophils human beings in response to the peptide chemotactic FMLP: comparison with the ionophore of calcium A23187

    International Nuclear Information System (INIS)

    Garcia, J.

    2000-01-01

    The calcium ionophore ionomycin primes polymorphonuclear leukocytes (PMN) for increased superoxide production upon stimulation with the chemotactic peptide FMLP (Helman Finkel, T. et al J Biol Chem 1987; 262: 12589-12596) In this investigation we assessed the effect of PMN priming with either alpha hemolysin (AH) or the calcium ionophore A23187, both of which increase intracellular calcium, on the oxidative metabolism of PMN (as measured by chemiluminescence) in response to secondary stimulation with FMLP. Both A23187 and AH priming increased, the luminol-enhanced chemiluminescence in response to secondary stimulation with FMLP, indicating overstimulation of PMLP oxidative metabolism. Additional experiments using lucigenin as chemiluminescence enhancer showed that A23187, but not AH priming of PMN, increased superoxide release in a manner similar to that reported for ionomycin. These results are discussed in reference to infectious processes involving hemolytic E. coli (Author) [es

  9. Transfusion transmittable infections - Seroprevalence among blood donors in a tertiary care hospital of Delhi

    Directory of Open Access Journals (Sweden)

    Sangeeta Pathak

    2013-01-01

    Full Text Available Context: Transfusion transmittable infections (TTI continue to be a major threat to safe transfusion practices. Blood is one of the major sources of transmission of infectious diseases viz. human immunodeficiency virus (HIV, hepatitis B virus (HBV, hepatitis C virus (HCV, syphilis, malaria, and many other infections in India. Screening assays for the infectious diseases with excellent sensitivity and specificity helps to enhance the safety of the blood transfusions reducing the diagnostic window period as much as possible. Aims: The present study was designed to determine the seroprevalence of TTIs viz., HIV, HCV, and HBV, among the blood donors in Max Super Specialty Hospital, New Delhi, India based on dual testing strategy using high sensitive screening assays such as enhanced chemiluminescence assay and nucleic acid testing (NAT. Materials and Methods: A total of 41207 blood units collected from the donors (both voluntary and replacement donors were screened for the TTI s, viz., anti HIV 1 and 2 antibody, anti HCV antibody, anti HBcore antibody, and HBsAg by enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system. NAT was performed using Roche Cobas ® TaqScreen MPX assay, which can detect simultaneously HIV 1 (groups M and O, HIV-2, HCV, and HBV on Roche Cobas ® s201 system. Results: The seroprevalence of HIV, HBsAg, anti HBcore antibody, and HCV based on enhanced chemiluminescence assay was found to be 0.25, 0.2, 7.06, and 0.7%, respectively. A total number of 6587 samples from July 2010 to December 2010 were tested on NAT, of which 3 samples were reactive for HBV in NAT; this was missed by enhanced chemiluminescence assay. Conclusions: Based on the seroprevalence study of infectious diseases viz., HIV, HBV, and HCV, we conclude that screening of blood and blood components by dual testing strategy using high sensitivity serological assay like enhanced chemiluminescence technology and NAT helps in detecting the

  10. Performance evaluation of a novel chemiluminescence assay for detection of anti-GBM antibodies: an international multicenter study.

    Science.gov (United States)

    Mahler, Michael; Radice, Antonella; Sinico, Renato A; Damoiseaux, Jan; Seaman, Andrea; Buckmelter, Kristen; Vizjak, Alenka; Buchner, Carol; Binder, Walter L; Fritzler, Marvin J; Cui, Zhao

    2012-01-01

    Autoantibodies to the non-collagen region (NC1) of the alpha-3 subunit of collagen IV represent a serological hallmark in the diagnosis of Goodpasture's syndrome (GPS). The objective of our study was to carefully analyze the performance characteristics of a novel anti-glomerular basement membrane (GBM) chemiluminescence immunoassay (CIA). Sera from patients with GPS (n = 90) were collected from four clinical centers. Samples from different disease groups (n = 397) and healthy individuals (n = 400) were used as controls. All samples were tested for anti-GBM antibodies by a rapid, random access CIA (QUANTA Flash™ GBM). Most of the samples were also tested using other methods including different commercial anti-GBM IgG assays and research assays for anti-GBM IgA and IgM. The sensitivity and specificity of the novel CIA was 95.6% [95% confidence interval (CI) 89.0-98.8%] and 99.6% (95% CI 98.9-99.9%), respectively. Receiver operating characteristic analysis showed good discrimination between GPS patients and controls. The area under the curve was 0.98 (CI 0.96-1.0). The three anti-GBM antibody-positive samples from the control group were from two healthy individuals and one human immunodeficiency virus (HIV)-infected patient. All three individuals had low levels of anti-GBM antibodies [20, 24 and 25 chemiluminescent unit (CU), cutoff 20 CU]. When the results of the new CIA were compared to other methods, good agreement was observed: 95.8% (kappa = 0.92) versus EliA™ GBM, 97.4% (kappa = 0.95) versus both BINDAZYME™ Anti-GBM and QUANTA Lite® GBM. Anti-GBM IgA was detectable in low concentrations in patients with GPS and was associated with anti-GBM IgG but was less useful in discriminating GPS patients and controls. No discrimination was found for anti-GBM IgM. The novel QUANTA Flash™ GBM CIA demonstrated good sensitivity and specificity and had good agreement with other methods. Our data confirm that ∼5% of patients with GPS do not have detectable levels of

  11. Field-Portable Immunoassay Instruments and Reagents to Measure Chelators and Mobile Forms of Uranium

    International Nuclear Information System (INIS)

    Blake, Diane A.

    2006-01-01

    Progress Report Date: 01/23/06 (report delayed due to Hurricane Katrina) Report of results to date: The goals of this 3-year project are to: (1) update and successfully deploy our present immunosensors at DOE sites; (2) devise immunosensor-based assays for Pb(II), Hg(II), chelators, and/or Cr(III) in surface and groundwater; and (3) develop new technologies in antibody engineering that will enhance this immunosensor program. Note: Work on this project was temporarily disrupted when Hurricane Katrina shut down the University on August 29, 2005. While most of the reagents stored in our refrigerators and freezers were destroyed, all of our hybridoma cell lines were saved because they had been stored in liquid nitrogen. We set up new tissue culture reactors with the hybridomas that synthesize the anti-uranium antibodies, and are purifying new monoclonal antibodies from these culture supernatants. Both the in-line and the field-portable sensor were rescued from our labs in New Orleans in early October, and we continued experiments with these sensors in the temporary laboratory we set up in Hammond, LA at Southeastern Louisiana University

  12. In situ-synthesized cadmium sulfide nanowire photosensor with a parylene passivation layer for chemiluminescent immunoassays.

    Science.gov (United States)

    Im, Ju-Hee; Kim, Hong-Rae; An, Byoung-Gi; Chang, Young Wook; Kang, Min-Jung; Lee, Tae-Geol; Son, Jin Gyeng; Park, Jae-Gwan; Pyun, Jae-Chul

    2017-06-15

    The direct in situ synthesis of cadmium sulfide (CdS) nanowires (NWs) was presented by direct synthesis of CdS NWs on the gold surface of an interdigitated electrode (IDE). In this work, we investigated the effect of a strong oxidant on the surfaces of the CdS NWs using X-ray photoelectron spectroscopy, transmission electron microscopy, and time-of-flight secondary ion mass spectrometry. We also fabricated a parylene-C film as a surface passivation layer for in situ-synthesized CdS NW photosensors and investigated the influence of the parylene-C passivation layer on the photoresponse during the coating of parylene-C under vacuum using a quartz crystal microbalance and a photoanalyzer. Finally, we used the in situ-synthesized CdS NW photosensor with the parylene-C passivation layer to detect the chemiluminescence of horseradish peroxidase and luminol and applied it to medical detection of carcinoembryonic antigen. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Assay of picogram level isocarbophos residue on tangerines and oranges with luminol-albumin chemiluminescence system.

    Science.gov (United States)

    Chen, Donghua; Song, Zhenghua; Lv, Hairu

    2012-12-15

    A sensitive flow injection-chemiluminescence (FI-CL) method for the determination of isocarbophos (ICP) residue on tangerines and oranges was proposed. It was found that the CL intensity from luminol-albumin CL reaction could be obviously quenched in the presence of ICP and the decrease in CL intensity was proportional to the logarithm of ICP concentrations ranging from 1.0 to 1000 pmol L(-1), giving the limit of detection of 0.3 pmol L(-1) (3σ). The proposed procedure was successfully applied to the determination of ICP residue on tangerines and oranges with recoveries varying from 92.0 to 111.0% and RSDs less than 5.0%. The possible CL mechanism of luminol-albumin-ICP reaction was discussed, and ICP to albumin's binding constant (K(D)=1.00 × 10(6) L mol(-1)) and the number of binding sites (n=1.00) were given by the homemade FI-CL model. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Synthesis, Photophysics, Electrochemistry and Electrogenerated Chemiluminescence of a Homologous Set of BODIPY-Appended Bipyridine Derivatives.

    Science.gov (United States)

    Rosenthal, Joel; Nepomnyashchii, Alexander B; Kozhukh, Julia; Bard, Allen J; Lippard, Stephen J

    2011-09-15

    Two new 2,2'-bipyridine (bpy) based ligands with ancillary BODIPY chromophores attached at the 4 and 4'-positions were prepared and characterized, which vary in the substitution pattern about the BODIPY periphery by either excluding (BB1) or including (BB2) a β-alkyl substituent. Both absorb strongly throughout the visible region and are strongly emissive. The basic photophysics and electrochemical properties of BB1 and BB2 are comparable to those of the BODIPY monomers on which they are based. The solid-state structures and electronic structure calculations both indicate that there is negligible electronic communication between the BODIPY moieties and the intervening bpy spacers. Electrogenerated chemiluminescence spectra of the two Bpy-BODIPY derivatives are similar to their recorded fluorescence profiles and are strongly influenced by substituents on the BODIPY chromophores. These 2,2'-bipyridine derivatives represent a new set of ligands that should find utility in applications including light-harvesting, photocatalysis, and molecular electronics.

  15. Flow injection chemiluminescent determination of N-nitrosodimethylamine using photogenerated tris(2,2'-bipyridyl) ruthenium (III)

    International Nuclear Information System (INIS)

    Perez-Ruiz, Tomas; Martinez-Lozano, Carmen; Tomas, Virginia; Martin, Jesus

    2005-01-01

    A flow injection configuration was developed and evaluated for the chemiluminescent determination of N-nitrosodimethylamine. The method is based on the on-line cleavage of the N-NO bond of the nitrosamine by irradiation with ultraviolet light. The dimethylamine generated was subsequently reacted with tris(2,2'-bipyridyl) ruthenium (III), which was generated through the on-line photo-oxidation of tris(2,2'-bipyridyl) ruthenium (II) with peroxydisulfate. After selecting the best operating parameters, the emitted light showed a linear relationship with the concentration of N-nitrosodimethylamine between 1.5 and 148 ng ml -1 , with a detection limit of 0.29 ng ml -1 . The repeatability was 1.6% expressed as relative standard deviation (n = 10) and the reproducibility, studied on five consecutive days, was 3.2%. The sample throughput was 50 injections per hour. The method was applied to studying the recoveries of N-nitrosodimethylamine in water and different cured meat products

  16. Low level chemiluminescence measurement of the binding of 8-methoxypsoralen to proteins and lymphocytic surfaces

    International Nuclear Information System (INIS)

    Lange, B.

    1980-01-01

    Photochemotherapy with 8-methoxypsoralen (8-MOP) and longwave ultraviolet light is beneficial in such different disorders like psoriasis, lichen planus, and mykosis fungoides. In contrast to a widely accepted hypothesis 8-MOP does not solely bind to nucleic acid, but also to certain proteins. The mechanism of this binding as well as the precise binding area are unknown. Therefore the UV-provoked reactions of 8-MOP with a lipid mixture, a glucosaminoglycan solution, a protein solution, and lymphocyte suspensions, respectively were investigated using low level chemiluminescence (LLCL). It was found an 8-MOP concentration-dependent decrease of LLCL intensity in the lymphocyte suspensions (10 3 to 10 4 cells/μl). This effect is result of the diminution of the photoactive 8-MOP content of the solution. 8-MOP binds quickly and in the course of a free radical reaction to lymphocytic surfaces and coincidentally loses its potency to start LLCL-detectable free radical chain responses. (author)

  17. A new luminol chemiluminescence sensor for glucose based on pH-dependent graphene oxide.

    Science.gov (United States)

    Hao, Minjia; Liu, Na; Ma, Zhanfang

    2013-08-07

    In this study, graphene oxide (GO) was found to catalyze the luminol-O2 reaction, which yielded a novel chemiluminescence (CL). Remarkably, the CL emission could be tuned by modulating the pH of the GO dispersion. Transmission electron microscopy, CL spectra, electron spin resonance spectra studies were carried out to investigate the CL mechanism. The results indicate that the CL emission was attributed to the intrinsic catalytic effect of GO acting as the radical generation proliferators and electron transfer accelerators. Based on the GO catalyzed luminol-O2 system, we successfully developed a new CL sensor to detect glucose. Under the optimized conditions, glucose could be assayed in the range of 0.05 mM to 5 mM with a detection limit of 0.044 mM. For the detection of clinical serum samples, it is well consistent with the data determined by commercially available method in hospital, indicating that the new CL method provides a possible application for the detection of glucose in clinical diagnostics.

  18. Clinical significance of quantitative analysis of thyroid peroxidase antibody (TPOAb) with chemiluminescence enzyme immunoassay

    International Nuclear Information System (INIS)

    Zhu Cuiying; Wang Qing; Huang Gang

    2004-01-01

    Objective: The only method of laboratory diagnosis for autoimmune thyroid diseases used to be serum TGA and TMA detections. Morerecently, quantitative analysis of TPOAb has been introduced. To assess the relative sensitivity of these tests , positive rates detected with the respective tests were compared. Methods: Serum TGA, TMA (with RIA) and TPOAb (with chemiluminescence enzyme immunoassay) were simultaneously detected in 998 cases of thyroid diseases (hyperthyroidism 307, Hashimoto's disease 193, simple goiter 498). For complementary sake, fine needle aspiration cytology was obtained in a number of cases including all the patients with Hashimoto's disease. Results: Positive detection rate of TPOAb in three groups of patients (hyperthyroidism, Hashimoto's, simple goiter) was 81.76%, 96.89 % and 42.97% respectively. With TMA, the positive rate was only 54.72%, 65.80%, 22.09% respectively. About one third more cases would be detected with the newer method. Conclusion: For the laboratory detection of auto immune thyroid diseases, quantitative analysis of TPOAb is much wore sensitive than the conventional TMA detection. (authors)

  19. Plasma treatment of paper for protein immobilization on paper-based chemiluminescence immunodevice.

    Science.gov (United States)

    Zhao, Mei; Li, Huifang; Liu, Wei; Guo, Yumei; Chu, Weiru

    2016-05-15

    A novel protein immobilization method based on plasma treatment of paper on the low-cost paper-based immunodevice was established in this work. By using a benchtop plasma cleaner, the paper microzone was treated by oxygen plasma treatment for 4 min and then the antibody can be directly immobilized on the paper surface. Aldehyde group was produced after the plasma treatment, which can be verified from the fourier transform infrared spectroscopy (FT-IR) spectra and x-ray photoelectron spectroscopy (XPS) spectra. By linked to aldehyde group, the antibody can be immobilized on the paper surface without any other pretreatment. A paper-based immunodevice was introduced here through this antibody immobilization method. With sandwich chemiluminescence (CL) immunoassay method, the paper-based immunodevice was successfully performed for carcinoembryonic antigen (CEA) detection in human serum with a linear range of 0.1-80.0 ng/mL. The detection limit was 0.03 ng/mL, which was 30 times lower than the clinical CEA level. Comparing to the other protein immobilization methods on paper-based device, this strategy was faster and simpler and had potential applications in point-of-care testing, public health and environmental monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Ultrasensitive Nanoimmunosensor by coupling non-covalent functionalized graphene oxide platform and numerous ferritin labels on carbon nanotubes.

    Science.gov (United States)

    Akter, Rashida; Jeong, Bongjin; Choi, Jong-Soon; Rahman, Md Aminur

    2016-06-15

    An ultrasensitive electrochemical nanostructured immunosensor for a breast cancer biomarker carbohydrate antigen 15-3 (CA 15-3) was fabricated using non-covalent functionalized graphene oxides (GO/Py-COOH) as sensor probe and multiwalled carbon nanotube (MWCNTs)-supported numerous ferritin as labels. The immunosensor was constructed by immobilizing a monoclonal anti-CA 15-3 antibody on the GO modified cysteamine (Cys) self-assembled monolayer (SAM) on an Au electrode (Au/Cys) through the amide bond formation between the carboxylic acid groups of GO/Py-COOH and amine groups of anti-CA 15-3. Secondary antibody conjugated MWCNT-supported ferritin labels (Ab2-MWCNT-Ferritin) were prepared through the amide bond formation between amine groups of Ab2 and ferritin and carboxylic acid groups of MWCNTs. The detection of CA 15-3 was based on the enhanced bioelectrocatalytic reduction of hydrogen peroxide mediated by hydroquinone (HQ) at the GO/Py-COOH-based sensor probe. The GO/Py-COOH-based sensor probe and Ab2-MWCNT-Ferritin labels were characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscope (SEM), transmission electron microscope (TEM), and x-ray photoelectron spectroscopy (XPS) techniques. Using differential pulse voltammetry (DPV) technique, CA 15-3 can be selectively detected as low as 0.01 ± 0.07 U/mL in human serum samples. Additionally, the proposed CA 15-3 immunosensor showed excellent selectivity and better stability in human serum samples, which demonstrated that the proposed immunosensor has potentials in proteomic researches and diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.