WorldWideScience

Sample records for engelbrecht avo mgi

  1. Bayesian seismic AVO inversion

    Energy Technology Data Exchange (ETDEWEB)

    Buland, Arild

    2002-07-01

    A new linearized AVO inversion technique is developed in a Bayesian framework. The objective is to obtain posterior distributions for P-wave velocity, S-wave velocity and density. Distributions for other elastic parameters can also be assessed, for example acoustic impedance, shear impedance and P-wave to S-wave velocity ratio. The inversion algorithm is based on the convolutional model and a linearized weak contrast approximation of the Zoeppritz equation. The solution is represented by a Gaussian posterior distribution with explicit expressions for the posterior expectation and covariance, hence exact prediction intervals for the inverted parameters can be computed under the specified model. The explicit analytical form of the posterior distribution provides a computationally fast inversion method. Tests on synthetic data show that all inverted parameters were almost perfectly retrieved when the noise approached zero. With realistic noise levels, acoustic impedance was the best determined parameter, while the inversion provided practically no information about the density. The inversion algorithm has also been tested on a real 3-D dataset from the Sleipner Field. The results show good agreement with well logs but the uncertainty is high. The stochastic model includes uncertainties of both the elastic parameters, the wavelet and the seismic and well log data. The posterior distribution is explored by Markov chain Monte Carlo simulation using the Gibbs sampler algorithm. The inversion algorithm has been tested on a seismic line from the Heidrun Field with two wells located on the line. The uncertainty of the estimated wavelet is low. In the Heidrun examples the effect of including uncertainty of the wavelet and the noise level was marginal with respect to the AVO inversion results. We have developed a 3-D linearized AVO inversion method with spatially coupled model parameters where the objective is to obtain posterior distributions for P-wave velocity, S

  2. Mouse Genome Informatics (MGI)

    Data.gov (United States)

    U.S. Department of Health & Human Services — MGI is the international database resource for the laboratory mouse, providing integrated genetic, genomic, and biological data to facilitate the study of human...

  3. Science from the Avo 1ST Light: the High Redshift Universe

    Science.gov (United States)

    Walton, Nicholas A.

    The Astrophysical Virtual Observatory science working group defined a number of key science drivers for which the AVO should develop capabilities. At the AVO's Jan 2003 'First Light' event the AVO prototype data access and manipulation tool was demonstrated. In particular its use in enabling discovery in deep multi wavelength data sets was highlighted. In this presentation I will describe how the AVO demonstrator has enabled investigation into the high redshift universe and in particular its use in discovering rare populations of high redshift galaxies from deep Hubble and ground based imaging data obtained through the Great Observatories Origins Deep Survey (GOODS) programme.

  4. Preface of Special issue on Automated Verification of Critical Systems (AVoCS'14)

    NARCIS (Netherlands)

    Huisman, Marieke; van de Pol, Jaco

    2016-01-01

    AVoCS 2014, the 14th International Conference on Automated Verification of Critical Systems has been hosted by the University of Twente, and has taken place in Enschede, Netherlands, on 24–26 September, 2014. The aim of the AVoCS series is to contribute to the interaction and exchange of ideas among

  5. Bayesian inversion of synthetic AVO data to assess fluid and shale ...

    Indian Academy of Sciences (India)

    A Bayesian inversion scheme for estimating reservoir parameters from amplitude vs. offset (AVO) data was used to obtain the information about uncertainties as well as their most likely values. The results from our workflow give reliable estimates of water saturation from AVO data at small uncertainties, provided background ...

  6. Bayesian inversion of synthetic AVO data to assess fluid and shale ...

    Indian Academy of Sciences (India)

    Hafiz Mubbasher Anwer

    Rock-physics models are often used to link ... AVO data, i.e., reflection coefficients from top ... sion method for estimation of reservoir parameters ..... the probability of finding the elliptic shale inclusion or spatial ..... Science & Business Media.

  7. Analysis and Interpretation of Avo Data in Buit-North Prospect of the Niger Delta Slope

    International Nuclear Information System (INIS)

    Oladapo, M.I.; Ojo, J. S.; Adetola, B.A.

    2003-01-01

    A qualitative analysis and interpretation of Amplitude Variations with Offset (AVO) data from Buit-North prospect in the Niger Delta Slope has been undertaken. Four horizons evaluated are AA (1900mm), BB (2345m), CC (2500m) and DD (2935). The work involved the comparison of AVO analysis of Buit-I well log and those of 3-D Pre-Stack Time Migrated (PSTM) seismic data acquired from the study area. Acoustic Impedance-Depth trend generated from Buit-1 Well demonstrates that AVO interpretation at depths between 2650m and .3300m (points of polynomial fit convergence) may be subdued due to nera zero impedance contrasts at contacts. Monte-Carlo models generated for the horizons using parameters measured from Buit. Zoeppritz (AVO) curves and seismic attributes crossplots were generated for all the horizons. AA horizon exhibit classes II and IV (falling AVO) while horizon BB reveal class III (classical bright spot) gas sand. Horizon CC exhibit class II (near zero impedance) gas sand while the seismic attributes crossplots show no distinct anomalous plots. The AVO response curves displayed at the upper level of horizon DD is characteristic of class IV response with the lower level exhibiting class II attribute. The seismic attributes crossplots for DD show plots on quandrants II, III and IV thus confirmation AVO analysis complexity within that depth window. Quantitative analysis and interpretation of AVO data is demonstrated in this study as a valuable emerging technology for appraising deep-water prospects for the delineation of probable hydrocarbon zones for further studies

  8. MouseMine: a new data warehouse for MGI.

    Science.gov (United States)

    Motenko, H; Neuhauser, S B; O'Keefe, M; Richardson, J E

    2015-08-01

    MouseMine (www.mousemine.org) is a new data warehouse for accessing mouse data from Mouse Genome Informatics (MGI). Based on the InterMine software framework, MouseMine supports powerful query, reporting, and analysis capabilities, the ability to save and combine results from different queries, easy integration into larger workflows, and a comprehensive Web Services layer. Through MouseMine, users can access a significant portion of MGI data in new and useful ways. Importantly, MouseMine is also a member of a growing community of online data resources based on InterMine, including those established by other model organism databases. Adopting common interfaces and collaborating on data representation standards are critical to fostering cross-species data analysis. This paper presents a general introduction to MouseMine, presents examples of its use, and discusses the potential for further integration into the MGI interface.

  9. Avo analysis in the high impedance reservoir of Chuchupa Field

    International Nuclear Information System (INIS)

    Cediel Mauricio; Almanza Ovidio; Montes Luis

    2012-01-01

    The technique of bright spot as a direct indicator of hydrocarbons has been widely used since the work of Ostrander (1984), particularly in gas fields. Located at north of Colombia, the Chuchupa field has produced gas continuously during 30 years, but despite the coverage with 2D seismic, amplitude anomalies associated with gas accumulation have not been observed. In order to find the relationships between the amplitude information and the gas accumulation, an AVO analysis was performed to describe the seismic reservoir response. The raw data of a 2D seismic line that crosses the field from East to West and a well log data set were used. In a first approach the seismic response was modeled using well logs, so a comparative analysis between the furnished synthetic seismograms and the real CDP gathers was done. The results indicated that the reservoirs top is represented by a low amplitude peak which decreases when the offset increases but whose phase remains unchanged. In the well, where the reservoir has 100% gas saturation, a high correlation between the synthetic and real CDP gathers was observed. In a second approach, anomalous clustered points in the IV quadrant were discriminated through intercept versus gradient cross plot analysis. A weak Class-I anomaly was identified, which could not be observed in stacked sections and hence it should be analyzed using pre-stack data.

  10. Lines of MgI Detected in Solar Prominences

    Czech Academy of Sciences Publication Activity Database

    Heinzel, Petr; Kupryakov, Yu. A.; Schwartz, P.

    2016-01-01

    Roč. 40, č. 1 (2016), s. 87-91 ISSN 1845-8319. [Hvar Astrophysical Colloquium /14./. Hvar, 26.09.2016-30.09.2016] Institutional support: RVO:67985815 Keywords : prominences * limb-flare * MgI emession Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  11. An analysis of AVO inversion for postcritical offsets in HTI media

    KAUST Repository

    Skopintseva, Lyubov; Alkhalifah, Tariq Ali

    2013-01-01

    Azimuthal variations of wavefield characteristics, such as traveltime or reflection amplitude, play an important role in the identification of fractured media. A transversely isotropic medium with a horizontal symmetry axis (HTI medium) is the simplest azimuthally anisotropic model typically used to describe one set of vertical fractures. There exist many techniques in industry to recover anisotropic parameters based on moveout equations and linearized reflection coefficients using such a model. However, most of the methods have limitations in defining properties of the fractures due to linearizations and physical approximations used in their development. Thus, azimuthal analysis of traveltimes based on normal moveout ellipses recovers a maximum of three medium parameters instead of the required five. Linearizations made in plane-wave reflection coefficients (PWRCs) limit the amplitude-versus-offset (AVO) analysis to small incident angles and weak-contrast interfaces. Inversion based on azimuthal AVO for small offsets encounters nonuniqueness in the resolving power of the anisotropy parameters. Extending the AVO analysis and inversion to and beyond the critical reflection angle increases the amount of information recovered from the medium. However, well-accepted PWRCs are not valid in the vicinity of the critical angle and beyond it, due to frequency and spherical wave effects. Recently derived spherical and effective reflection coefficient (ERC) methods overcome this problem. We extended the ERCs approach to HTI media to analyze the potential of near- and postcritical reflections in azimuthal AVO analysis. From the sensitivity analysis, we found that ERCs are sensitive to different sets of parameters prior to and beyond the critical angle, which is useful in enhancing our resolution of the anisotropy parameters. Additionally, the resolution of the parameters depends on a sufficient azimuthal coverage in the acquisition setup. The most stable AVO results for the

  12. An analysis of AVO inversion for postcritical offsets in HTI media

    KAUST Repository

    Skopintseva, Lyubov

    2013-04-12

    Azimuthal variations of wavefield characteristics, such as traveltime or reflection amplitude, play an important role in the identification of fractured media. A transversely isotropic medium with a horizontal symmetry axis (HTI medium) is the simplest azimuthally anisotropic model typically used to describe one set of vertical fractures. There exist many techniques in industry to recover anisotropic parameters based on moveout equations and linearized reflection coefficients using such a model. However, most of the methods have limitations in defining properties of the fractures due to linearizations and physical approximations used in their development. Thus, azimuthal analysis of traveltimes based on normal moveout ellipses recovers a maximum of three medium parameters instead of the required five. Linearizations made in plane-wave reflection coefficients (PWRCs) limit the amplitude-versus-offset (AVO) analysis to small incident angles and weak-contrast interfaces. Inversion based on azimuthal AVO for small offsets encounters nonuniqueness in the resolving power of the anisotropy parameters. Extending the AVO analysis and inversion to and beyond the critical reflection angle increases the amount of information recovered from the medium. However, well-accepted PWRCs are not valid in the vicinity of the critical angle and beyond it, due to frequency and spherical wave effects. Recently derived spherical and effective reflection coefficient (ERC) methods overcome this problem. We extended the ERCs approach to HTI media to analyze the potential of near- and postcritical reflections in azimuthal AVO analysis. From the sensitivity analysis, we found that ERCs are sensitive to different sets of parameters prior to and beyond the critical angle, which is useful in enhancing our resolution of the anisotropy parameters. Additionally, the resolution of the parameters depends on a sufficient azimuthal coverage in the acquisition setup. The most stable AVO results for the

  13. Multi-MGy Radiation Hardened Camera for Nuclear Facilities

    International Nuclear Information System (INIS)

    Girard, Sylvain; Boukenter, Aziz; Ouerdane, Youcef; Goiffon, Vincent; Corbiere, Franck; Rolando, Sebastien; Molina, Romain; Estribeau, Magali; Avon, Barbara; Magnan, Pierre; Paillet, Philippe; Duhamel, Olivier; Gaillardin, Marc; Raine, Melanie

    2015-01-01

    There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO 2 ) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera

  14. Multi-MGy Radiation Hardened Camera for Nuclear Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Girard, Sylvain; Boukenter, Aziz; Ouerdane, Youcef [Universite de Saint-Etienne, Lab. Hubert Curien, UMR-CNRS 5516, F-42000 Saint-Etienne (France); Goiffon, Vincent; Corbiere, Franck; Rolando, Sebastien; Molina, Romain; Estribeau, Magali; Avon, Barbara; Magnan, Pierre [ISAE, Universite de Toulouse, F-31055 Toulouse (France); Paillet, Philippe; Duhamel, Olivier; Gaillardin, Marc; Raine, Melanie [CEA, DAM, DIF, F-91297 Arpajon (France)

    2015-07-01

    There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO{sub 2}) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera

  15. Fuel retention and recovery in natural and MGI disruptions on KSTAR

    International Nuclear Information System (INIS)

    Yu, Y.W.; Hong, S.H.; Yoon, S.W.; Kim, K.P.; Kim, W.C.; Seo, D.C.

    2013-01-01

    Fuel retention and recovery are studied during natural and Massive Gas Injection (MGI) induced disruptions in KSTAR with full graphite wall. The amount of released particles in natural disruptions in 15 s after the discharge is ∼5–10 times higher than that of non-disruption shots, but the difference is only ∼ 2 MGI induced disruptions depends on magnetic field (B t ) and MGI amount. The MGI disruption under a low B t and a medium MGI amount shows shorter thermal quench (TQ) and current quench (CQ), thereby higher fuel recovery. High B t plasma requires higher MGI amount for both disruption mitigation and fuel recovery. A high recovery of 4.2 × 10 22 D (∼0.78 monolayers) is obtained by MGI disruption in KSTAR 2011

  16. Formation, structure and magnetism of the metastable defect fluorite phases AVO3.5+x (A=In, Sc)

    International Nuclear Information System (INIS)

    Shafi, Shahid P.; Lundgren, Rylan J.; Cranswick, Lachlan M.D.; Bieringer, Mario

    2007-01-01

    We report the preparation and stability of ScVO 3.5+x and the novel phase InVO 3.5+x . AVO 3.5+x (A=Sc, In) defect fluorite structures are formed as metastable intermediates during the topotactic oxidation of AVO 3 bixbyites. The oxidation pathway has been studied in detail by means of thermogravimetric/differential thermal analysis and in-situ powder X-ray diffraction. The oxidation of the bixbyite phase follows a topotactic pathway at temperatures between 300 and 400 deg. C in air/carbon dioxide. The range of accessible oxygen stoichiometries for the AVO 3.5+x structures following this pathway are 0.00≤x≤0.22. Rietveld refinements against powder X-ray and neutron data revealed that InVO 3.54 and ScVO 3.70 crystallize in the defect fluorite structure in space group Fm-3 m (227) with a=4.9863(5) and 4.9697(3)A, respectively with A 3+ /V 4+ disorder on the (4a) cation site. Powder neutron diffraction experiments indicate clustering of oxide defects in all samples. Bulk magnetic measurements showed the presence of V 4+ and the absence of magnetic ordering at low temperatures. Powder neutron diffraction experiments confirmed the absence of a long range ordered magnetic ground state. - Graphical abstract: Topotactic oxidation of AVO 3 bixbyite to AVO 3.5 defect fluorite structure followed by in-situ powder X-ray diffraction. The upper structural diagram shows a six coordinated (A/V)-O 6 fragment in bixbyite, the lower structure illustrates the same seven-fold coordinated (A/V)-O 7 cubic environment in the defect fluorite structure

  17. Mouse Genome Informatics (MGI) Resource: Genetic, Genomic, and Biological Knowledgebase for the Laboratory Mouse.

    Science.gov (United States)

    Eppig, Janan T

    2017-07-01

    The Mouse Genome Informatics (MGI) Resource supports basic, translational, and computational research by providing high-quality, integrated data on the genetics, genomics, and biology of the laboratory mouse. MGI serves a strategic role for the scientific community in facilitating biomedical, experimental, and computational studies investigating the genetics and processes of diseases and enabling the development and testing of new disease models and therapeutic interventions. This review describes the nexus of the body of growing genetic and biological data and the advances in computer technology in the late 1980s, including the World Wide Web, that together launched the beginnings of MGI. MGI develops and maintains a gold-standard resource that reflects the current state of knowledge, provides semantic and contextual data integration that fosters hypothesis testing, continually develops new and improved tools for searching and analysis, and partners with the scientific community to assure research data needs are met. Here we describe one slice of MGI relating to the development of community-wide large-scale mutagenesis and phenotyping projects and introduce ways to access and use these MGI data. References and links to additional MGI aspects are provided. © The Author 2017. Published by Oxford University Press.

  18. The radiation asymmetry in MGI rapid shutdown on J-TEXT tokamak

    Science.gov (United States)

    Tong, Ruihai; Chen, Zhongyong; Huang, Duwei; Cheng, Zhifeng; Zhang, Xiaolong; Zhuang, Ge; J-TEXT Team

    2017-10-01

    Disruptions, the sudden termination of tokamak fusion plasmas by instabilities, have the potential to cause severe material wall damage to large tokamaks like ITER. The mitigation of disruption damage is an essential part of any fusion reactor system. Massive gas injection (MGI) rapid shutdown is a technique in which large amounts of noble gas are injected into the plasma in order to safely radiate the plasma energy evenly over the entire plasma-facing first wall. However, the radiated energy during the thermal quench (TQ) in massive gas injection (MGI) induced disruptions is found toroidal asymmetric, and the degrees of asymmetry correlate with the gas penetration and MGI induced magnetohydrodynamics (MHD) activities. A toroidal and poloidal array of ultraviolet photodiodes (AXUV) has been developed to investigate the radiation asymmetry on J-TEXT tokamak. Together with the upgraded mirnov probe arrays, the relation between MGI triggered MHD activities with radiation asymmetry is studied.

  19. Mouse Genome Informatics (MGI) Is the International Resource for Information on the Laboratory Mouse.

    Science.gov (United States)

    Law, MeiYee; Shaw, David R

    2018-01-01

    Mouse Genome Informatics (MGI, http://www.informatics.jax.org/ ) web resources provide free access to meticulously curated information about the laboratory mouse. MGI's primary goal is to help researchers investigate the genetic foundations of human diseases by translating information from mouse phenotypes and disease models studies to human systems. MGI provides comprehensive phenotypes for over 50,000 mutant alleles in mice and provides experimental model descriptions for over 1500 human diseases. Curated data from scientific publications are integrated with those from high-throughput phenotyping and gene expression centers. Data are standardized using defined, hierarchical vocabularies such as the Mammalian Phenotype (MP) Ontology, Mouse Developmental Anatomy and the Gene Ontologies (GO). This chapter introduces you to Gene and Allele Detail pages and provides step-by-step instructions for simple searches and those that take advantage of the breadth of MGI data integration.

  20. Geologic data management at AVO: building authoritative coverage with radical availability (Invited)

    Science.gov (United States)

    Cameron, C.; Snedigar, S. F.; Nye, C. J.

    2009-12-01

    In 2002, the Alaska Volcano Observatory (AVO) began creating the Geologic Database of Information on Volcanoes in Alaska (GeoDIVA) to create a system that contains complete, flexible, timely, and accurate geologic and geographic information on Pleistocene and younger volcanoes in Alaska. This system was primarily intended to be a tool for scientific investigation, crisis response, and public information - delivered in a dynamic, digital format to both internal and external users. It is now the back-end of the AVO public website. GeoDIVA does not interface with our daily monitoring activities, however -- seismic and satellite data are handled by different database efforts. GeoDIVA also doesn’t store volcanic unrest data, although we hope WOVOdat will. GeoDIVA does include modules for the following datasets: bibliography (every subsequent piece of data in GeoDIVA is tied to a reference), basic volcano information (~137 edifices), historical eruption history information (~550 events), images (~17,000), sample information (~4400), geochemistry (~1500; population in progress), petrography (very early stages of data creation), sample storage (~14,000), and Quaternary vent information (~1200 vents). Modules in progress include GIS data, tephra data, and geochronologic data. In recent years, we have been doing maintenance work on older modules (for example, adding new references to the bibliography, and creating new queries and data fields in response to user feedback) as well as developing, designing, and populating new modules. Population can be quite time consuming, as there are no pre-compiled comprehensive existing sources for most information on Alaskan volcanoes, and we carefully reference each item. Newer modules also require more complex data arrangements than older modules. To meet the needs of a diverse group of users on widely varying computer platforms, GeoDIVA data is primarily stored in a MySQL DBMS; PostGIS/PostgreSQL are currently used to store and

  1. The time-lapse AVO difference inversion for changes in reservoir parameters

    Science.gov (United States)

    Longxiao, Zhi; Hanming, Gu; Yan, Li

    2016-12-01

    The result of conventional time-lapse seismic processing is the difference between the amplitude and the post-stack seismic data. Although stack processing can improve the signal-to-noise ratio (SNR) of seismic data, it also causes a considerable loss of important information about the amplitude changes and only gives the qualitative interpretation. To predict the changes in reservoir fluid more precisely and accurately, we also need the quantitative information of the reservoir. To achieve this aim, we develop the method of time-lapse AVO (amplitude versus offset) difference inversion. For the inversion of reservoir changes in elastic parameters, we apply the Gardner equation as the constraint and convert the three-parameter inversion of elastic parameter changes into a two-parameter inversion to make the inversion more stable. For the inversion of variations in the reservoir parameters, we infer the relation between the difference of the reflection coefficient and variations in the reservoir parameters, and then invert reservoir parameter changes directly. The results of the theoretical modeling computation and practical application show that our method can estimate the relative variations in reservoir density, P-wave and S-wave velocity, calculate reservoir changes in water saturation and effective pressure accurately, and then provide reference for the rational exploitation of the reservoir.

  2. Microstructural evolution during dry wear test in magnesium and Mg-Y alloy

    Energy Technology Data Exchange (ETDEWEB)

    Somekawa, Hidetoshi, E-mail: SOMEKAWA.Hidetoshi@nims.go.jp [Research Center for Strategic Materials, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Maeda, Shunsuke; Hirayama, Tomoko; Matsuoka, Takashi [Department of Mechanical Engineering, Doshisha University, 1-3 Miyakodani, Tatara, Kyotanabe 610-0321 (Japan); Inoue, Tadanobu [Research Center for Strategic Materials, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Mukai, Toshiji [Department of Mechanical Engineering, Kobe University, 1-1 Rokkodai, Kobe, 657-8501 (Japan)

    2013-01-20

    The friction and wear properties of pure magnesium and the Mg-Y alloy were investigated using the pin-on-disk configuration. The friction and wear resistance of the Mg-Y alloy was superior to those of pure magnesium. The wear mechanism was abrasion under all the conditions. The deformed microstructural evolutions near the surface region were observed by transmission electron microscopy and electron backscatter diffraction. The stress and strain states were also evaluated by finite element analysis (FEA). The deformed microstructures of both alloys consisted of the {l_brace}10-12{r_brace} twinning formation and the FEA results showed the occurrence of plastic deformation even at the beginning of the test. The formation of low angle grain boundaries was also confirmed with an increase in the applied load in the Mg-Y alloy. On the other hand, grain refinement due to dynamic recrystallization was observed in pure magnesium as the wear test progressed. The different microstructures resulted from difference in the surface temperature during the wear test, which was estimated to be around 393 K and 363 K for pure magnesium and the Mg-Y alloy, respectively. The high increment temperature in the fine-grained alloys brought about the occurrence of grain boundary sliding, i.e., material softening, which led to a decrease in the friction and wear properties. The present results indicated that one of the methods for enhancing the friction and wear properties is to increase the dynamic recrystallization temperature.

  3. Análisis de la amplitud referenciada con trayectorias de rayo y su aplicación en AVO

    Directory of Open Access Journals (Sweden)

    Bohórquez Q. Jesús G.

    2003-08-01

    Full Text Available

    The AVO analysis is based in variation of amplitude of waves with offset, due mainly to elastic properties of rocks. The variables characterizing the elastic behavior ofrocks, licke velocity of s-waves and attenuation, can be estimated by AVO analysis. This can be considered cheap in case ofland acquisition and possible in case of maxime acquisition. This paper describes a different methodology to use AVO, analyzing the relative change ofthe amplitude use with frequency between two reflectors, recovering the last energy of wave due transmission are conversion of wares affected by the angle of incidence.

    The method was applica to synthetic data of models with homogeneus and isotropic layers separated by plan-paralled interfaces, models associated to maxime depositation environment with low tectonic activity, with stratigraphic features as seen in wt plans in Colombia.

    EI análisis AVO se basa en la variación de amplitudes de ondas con el offset, determinada entre otras causas por las propiedades elásticas de las rocas.

    Las variables necesarias para caracterizar el comportamiento elástico de las rocas, como la velocidad de ondas-s y atenuación, se llegan a determinar mediante análisis AVO. La valoración de velocidades resulta menos costosa en unos casos, cuando el AVO

  4. HUBUNGAN CITRA MERK BUS (MGI DENGAN KEPUASAN KONSUMEN PADA TRAYEK BANDUNG-SUKABUMI

    Directory of Open Access Journals (Sweden)

    Ulfa Chairunnisa

    2018-02-01

    Full Text Available This research aims to study correlation between brand image and customer satisfaction. Quantitative design using correlational method involved 350 MGI bus customer in Bandung-Sukabumi route. Instruments used are Brand Image Inventory (37 item and Customer Satisfaction Index (37 item. Cooeficient  correlation resulted is 0.684 which means that there is positive correlation between brand image and customer satisfction. High brand image correlated with high customer satisfaction while low brand image correlated with low customer satisfaction.

  5. HUBUNGAN CITRA MERK BUS (MGI) DENGAN KEPUASAN KONSUMEN PADA TRAYEK BANDUNG-SUKABUMI

    OpenAIRE

    Ulfa Chairunnisa

    2018-01-01

    This research aims to study correlation between brand image and customer satisfaction. Quantitative design using correlational method involved 350 MGI bus customer in Bandung-Sukabumi route. Instruments used are Brand Image Inventory (37 item) and Customer Satisfaction Index (37 item). Cooeficient  correlation resulted is 0.684 which means that there is positive correlation between brand image and customer satisfction. High brand image correlated with high customer satisfaction while low bran...

  6. The influence of yttrium (Y) on the corrosion of Mg-Y binary alloys

    International Nuclear Information System (INIS)

    Liu Ming; Schmutz, Patrik; Uggowitzer, Peter J.; Song Guangling; Atrens, Andrej

    2010-01-01

    Research highlights: → The Y-intermetallic can accelerate corrosion and Y can increase the protectiveness of the surface layer. → In 0.1 M NaCl, the corrosion rate of Mg-Y alloys increased with increasing Y due to the Y intermetallic. → In 0.1 M NaCl, there was filiform corrosion. → In 0.1 M Na 2 SO 4 , the corrosion rate of Mg-Y alloys decreased with increasing Y in the range 3-7%Y. → Hydrogen evolution was observed from particular parts of the alloy surface. - Abstract: Corrosion of Mg-Y alloys was studied using electrochemical evaluations, immersion tests and direct observations. There were two important effects. In 0.1 M NaCl, the corrosion rate increased with increasing Y content due to increasing amounts of the Y-containing intermetallic. In 0.1 M Na 2 SO 4 , the corrosion rate decreased with increasing Y content above 3%, attributed to a more protective surface film, despite the intermetallic. The corrosion rate evaluated by electrochemical impedance spectroscopy was somewhat smaller than that evaluated from H evolution as expected from the Mg corrosion mechanism. A mechanism is proposed for filiform corrosion. Direct in situ corrosion observations revealed that a predominant feature was hydrogen evolution from particular parts of the alloy surface.

  7. Determination of gold and silver in geological standard samples MGI by instrument neutron activation analysis

    International Nuclear Information System (INIS)

    Lu Huijiuan; Zhou; Yunlu

    1987-01-01

    Gold and silver in geological standard samples MGI were determined by instrument neutron activation analysis. The various interferences of nuclides were considered. Corrected factors of the geometry in different positions have been determined. Using the geological standard sample MGM and radiochemical separation neutron activation method as reference, the reliability of this method is proved. Gold content in samples is 0.4-0.009 g/t, silver content is 9-0.3 g/t. Standard deviation is less than 3.5%, the precision of the measurement is 4.8-11.6%

  8. Effects of spin-orbit coupling on laser cooling of BeI and MgI

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Mingjie, E-mail: wanmingjie1983@sina.com; Huang, Duohui; Shao, Juxiang; Li, Yuanyuan [Computational Physics Key Laboratory of Sichuan Province, Yibin University, Yibin 644007 (China); Yu, You [College of Optoelectronic Technology, Chengdu University of Information Technology, Chengdu 610225 (China); Li, Song [College of Physical Science and Technology, Yangtze University, Jingzhou 434023 (China)

    2015-10-28

    We present the ab initio study of spin-orbit coupling effects on laser cooling of BeI and MgI molecules. Potential energy curves for the X{sup 2}Σ{sup +}{sub 1/2}, A{sup 2}Π{sub 1/2,3/2}, and 2{sup 2}Π{sub 3/2,1/2} states are calculated using multi-reference configuration interaction method plus Davidson corrections. Spectroscopic parameters of BeI and MgI are in excellent agreement with available experimental and theoretical values. The A{sup 2}Π{sub 3/2} state of MgI is a repulsive state. It is an unsuitable scheme for the A{sup 2}Π{sub 3/2}(υ′)← X{sup 2}Σ{sup +}{sub 1/2} (υ″) transition for laser cooling of MgI. Highly diagonally distributed Franck-Condon factors f{sub 00} for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) ← X{sup 2}Σ{sup +}{sub 1/2} (υ″ = 0) transitions and suitable radiative lifetimes τ for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) of BeI and MgI are obtained. Three laser wavelength drives are required for the A{sup 2}Π{sub 1/2,3/2}(υ′)←X{sup 2}Σ{sup +}{sub 1/2} (υ″) transitions of BeI and MgI. The proposed cooling wavelengths of BeI and MgI are both in the violet region. The results imply the feasibility of laser cooling of BeI and MgI, and that laser cooling of BeI is more possible.

  9. Investigations on MGy ionizing dose effects in thin oxides of micro-electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Gaillardin, M.; Paillet, P.; Raine, M.; Martinez, M.; Marcandella, C.; Duhamel, O.; Richard, N.; Leray, J.L. [CEA, DAM, DIF, F-91297 Arpajon (France); Goiffon, V.; Corbiere, F.; Rolando, S.; Molina, R.; Magnan, P. [ISAE, Universite de Toulouse, 10 avenue Edouard Belin, BP 54032, 31055 Toulouse Cedex 4 (France); Girard, S.; Ouerdane, Y.; Boukenter, A. [Universite de Saint-Etienne, Laboratoire H. Curien, UMR-5516, 42000, Saint-Etienne (France)

    2015-07-01

    Total ionizing dose (TID) effects have been studied for a long time in micro-electronic components designed to operate in natural and artificial environments. In most cases, TID induces both charge trapping in the bulk of irradiated oxides and the buildup of interface traps located at semiconductor/dielectric interfaces. Such effects result from basic mechanisms driven by both the shape of the electric field which stands into the oxide and by fabrication process parameters inducing pre-existing traps in the oxide's bulk. From the pioneering studies based on 'thick' oxide technologies to the most recent ones dedicated to innovative technologies, most studies concluded that the impact of total ionizing dose effects reduces with the oxide thinning. This is specifically the case for the gate-oxide of Metal-Oxide-Semiconductor Field Effect Transistors (MOSFET) for which it is generally considered that TID is not a major issue anymore at kGy dose ranges. TID effects are now mainly due to charge trapping in the field oxides such as Shallow Trench Isolation. This creates either parasitic conduction paths or Radiation-Induced Narrow Channel Effects (RINCE). Static current-voltage (I-V) electrical characteristics are then modified through a significant increase of the off-current of NMOS transistors or by shifting the whole I-V curves (of both NMOS and PMOS transistors). Based on these assumptions, no significant shift of I-V curves should be observed in modern bulk CMOS technologies. However, such phenomenon may not be directly extrapolated to higher TID ranges, typically of several MGy for which only few data are available in the literature. This paper presents evidences of large threshold voltage shifts measured at MGy dose levels despite the fact that transistors are designed in a submicron bulk technology which features a 7-nm thin gate-oxide on GO2 transistors dedicated to mixed analog/digital integrated circuits. Such electrical shifts are encountered

  10. Investigations on MGy ionizing dose effects in thin oxides of micro-electronic devices

    International Nuclear Information System (INIS)

    Gaillardin, M.; Paillet, P.; Raine, M.; Martinez, M.; Marcandella, C.; Duhamel, O.; Richard, N.; Leray, J.L.; Goiffon, V.; Corbiere, F.; Rolando, S.; Molina, R.; Magnan, P.; Girard, S.; Ouerdane, Y.; Boukenter, A.

    2015-01-01

    Total ionizing dose (TID) effects have been studied for a long time in micro-electronic components designed to operate in natural and artificial environments. In most cases, TID induces both charge trapping in the bulk of irradiated oxides and the buildup of interface traps located at semiconductor/dielectric interfaces. Such effects result from basic mechanisms driven by both the shape of the electric field which stands into the oxide and by fabrication process parameters inducing pre-existing traps in the oxide's bulk. From the pioneering studies based on 'thick' oxide technologies to the most recent ones dedicated to innovative technologies, most studies concluded that the impact of total ionizing dose effects reduces with the oxide thinning. This is specifically the case for the gate-oxide of Metal-Oxide-Semiconductor Field Effect Transistors (MOSFET) for which it is generally considered that TID is not a major issue anymore at kGy dose ranges. TID effects are now mainly due to charge trapping in the field oxides such as Shallow Trench Isolation. This creates either parasitic conduction paths or Radiation-Induced Narrow Channel Effects (RINCE). Static current-voltage (I-V) electrical characteristics are then modified through a significant increase of the off-current of NMOS transistors or by shifting the whole I-V curves (of both NMOS and PMOS transistors). Based on these assumptions, no significant shift of I-V curves should be observed in modern bulk CMOS technologies. However, such phenomenon may not be directly extrapolated to higher TID ranges, typically of several MGy for which only few data are available in the literature. This paper presents evidences of large threshold voltage shifts measured at MGy dose levels despite the fact that transistors are designed in a submicron bulk technology which features a 7-nm thin gate-oxide on GO2 transistors dedicated to mixed analog/digital integrated circuits. Such electrical shifts are encountered

  11. Target of rapamycin complex 2 signals to downstream effector yeast protein kinase 2 (Ypk2) through adheres-voraciously-to-target-of-rapamycin-2 protein 1 (Avo1) in Saccharomyces cerevisiae.

    Science.gov (United States)

    Liao, Hsien-Ching; Chen, Mei-Yu

    2012-02-24

    The conserved Ser/Thr kinase target of rapamycin (TOR) serves as a central regulator in controlling cell growth-related functions. There exist two distinct TOR complexes, TORC1 and TORC2, each coupling to specific downstream effectors and signaling pathways. In Saccharomyces cerevisiae, TORC2 is involved in regulating actin organization and maintaining cell wall integrity. Ypk2 (yeast protein kinase 2), a member of the cAMP-dependent, cGMP-dependent, and PKC (AGC) kinase family, is a TORC2 substrate known to participate in actin and cell wall regulation. Employing avo3(ts) mutants with defects in TORC2 functions that are suppressible by active Ypk2, we investigated the molecular interactions involved in mediating TORC2 signaling to Ypk2. GST pulldown assays in yeast lysates demonstrated physical interactions between Ypk2 and components of TORC2. In vitro binding assays revealed that Avo1 directly binds to Ypk2. In avo3(ts) mutants, the TORC2-Ypk2 interaction was reduced and could be restored by AVO1 overexpression, highlighting the important role of Avo1 in coupling TORC2 to Ypk2. The interaction was mapped to an internal region (amino acids 600-840) of Avo1 and a C-terminal region of Ypk2. Ypk2(334-677), a truncated form of Ypk2 containing the Avo1-interacting region, was able to interfere with Avo1-Ypk2 interaction in vitro. Overexpressing Ypk2(334-677) in yeast cells resulted in a perturbation of TORC2 functions, causing defective cell wall integrity, aberrant actin organization, and diminished TORC2-dependent Ypk2 phosphorylation evidenced by the loss of an electrophoretic mobility shift. Together, our data support the conclusion that the direct Avo1-Ypk2 interaction is crucial for TORC2 signaling to the downstream Ypk2 pathway.

  12. A MGy radiation-hardened sensor instrumentation link for nuclear reactor monitoring and remote handling

    Energy Technology Data Exchange (ETDEWEB)

    Verbeeck, Jens; Cao, Ying [KU Leuven - KUL, Div. LRD-MAGyICS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Van Uffelen, Marco; Mont Casellas, Laura; Damiani, Carlo; Morales, Emilio Ruiz; Santana, Roberto Ranz [Fusion for Energy - F4E, c/Josep,n deg. 2, Torres Diagonal Litoral, Ed. B3, 08019 Barcelona (Spain); Meek, Richard; Haist, Bernhard [Oxford Technologies Ltd. OTL, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); De Cock, Wouter; Vermeeren, Ludo [SCK-CEN, Boeretang 200, 2400 Mol (Belgium); Steyaert, Michiel [KU Leuven, ESAT-MICAS, KasteelparkArenberg 10, 3001 Heverlee (Belgium); Leroux, Paul [KU Leuven, ESAT-MICAS, KasteelparkArenberg 10, 3001 Heverlee (Belgium)

    2015-07-01

    Decommissioning, dismantling and remote handling applications in nuclear facilities all require robotic solutions that are able to survive in radiation environments. Recently raised safety, radiation hardness and cost efficiency demands from both the nuclear regulatory and the society impose severe challenges in traditional methods. For example, in case of the dismantling of the Fukushima sites, solutions that survive accumulated doses higher than 1 MGy are mandatory. To allow remote operation of these tools in nuclear environments, electronics were used to be shielded with several centimeters of lead or even completely banned in these solutions. However, shielding electronics always leads to bulky and heavy solutions, which reduces the flexibility of robotic tools. It also requires longer repair time and produces extra waste further in a dismantling or decommissioning cycle. In addition, often in current reactor designs, due to size restrictions and the need to inspect very tight areas there are limitations to the use of shielding. A MGy radiation-hardened sensor instrumentation link developed by MAGyICS provides a solution to build a flexible, easy removable and small I and C module with MGy radiation tolerance without any shielding. Hereby it removes all these pains to implement electronics in robotic tools. The demonstrated solution in this poster is developed for ITER Remote Handling equipments operating in high radiation environments (>1 MGy) in and around the Tokamak. In order to obtain adequately accurate instrumentation and control information, as well as to ease the umbilical management, there is a need of front-end electronics that will have to be located close to those actuators and sensors on the remote handling tool. In particular, for diverter remote handling, it is estimated that these components will face gamma radiation up to 300 Gy/h (in-vessel) and a total dose of 1 MGy. The radiation-hardened sensor instrumentation link presented here, consists

  13. Multivariate Formation Pressure Prediction with Seismic-derived Petrophysical Properties from Prestack AVO inversion and Poststack Seismic Motion Inversion

    Science.gov (United States)

    Yu, H.; Gu, H.

    2017-12-01

    A novel multivariate seismic formation pressure prediction methodology is presented, which incorporates high-resolution seismic velocity data from prestack AVO inversion, and petrophysical data (porosity and shale volume) derived from poststack seismic motion inversion. In contrast to traditional seismic formation prediction methods, the proposed methodology is based on a multivariate pressure prediction model and utilizes a trace-by-trace multivariate regression analysis on seismic-derived petrophysical properties to calibrate model parameters in order to make accurate predictions with higher resolution in both vertical and lateral directions. With prestack time migration velocity as initial velocity model, an AVO inversion was first applied to prestack dataset to obtain high-resolution seismic velocity with higher frequency that is to be used as the velocity input for seismic pressure prediction, and the density dataset to calculate accurate Overburden Pressure (OBP). Seismic Motion Inversion (SMI) is an inversion technique based on Markov Chain Monte Carlo simulation. Both structural variability and similarity of seismic waveform are used to incorporate well log data to characterize the variability of the property to be obtained. In this research, porosity and shale volume are first interpreted on well logs, and then combined with poststack seismic data using SMI to build porosity and shale volume datasets for seismic pressure prediction. A multivariate effective stress model is used to convert velocity, porosity and shale volume datasets to effective stress. After a thorough study of the regional stratigraphic and sedimentary characteristics, a regional normally compacted interval model is built, and then the coefficients in the multivariate prediction model are determined in a trace-by-trace multivariate regression analysis on the petrophysical data. The coefficients are used to convert velocity, porosity and shale volume datasets to effective stress and then

  14. Study on the early surface films formed on Mg-Y molten alloy in different atmospheres

    Directory of Open Access Journals (Sweden)

    A.R. Mirak

    2015-09-01

    Full Text Available In the present study, the non-isothermal early stages of surface oxidation of liquid Mg-1%Y alloy during casting were studied under UPH argon, dry air, and air mixed with protective fluorine-bearing gases. The chemistry and morphology of the surface films were characterized by SEM and EDX analyses. The results indicate a layer of smooth and tightly coherent oxidation film composed of MgO and Y2O3 formed on the molten Mg-Y alloy surface with 40–60 nm thickness under dry air. A dendritic/cellular microstructure is clearly visible with Y-rich second phases gathered in surface of the melt and precipitated along the grain/cell boundaries under all gas conditions. Under fluorine-bearing gas mixtures, the surface film was a mixed oxide and fluoride and more even; a flat and folded morphology can be seen under SF6 with oxide as dominated phase and under 1, 1, 1, 2-tetra-fluoroethane, a smooth and compact surface film uniformly covering the inner surface of the bubble with equal oxide and fluoride thickness, which results in a film without any major defects. MgF2 phase appears to be the key characteristic of a good protective film.

  15. In situ electrochemical XRD study of (de)hydrogenation of MgyTi100-y thin films

    NARCIS (Netherlands)

    Vermeulen, P.; Wondergem, H.J.; Graat, P.C.J.; Borsa, D.M.; Schreuders, H.; Dam, B.; Griessen, R.; Notten, P.H.L.

    2008-01-01

    X-ray diffraction and electrochemical (de)hydrogenation were performed in situ to monitor the symmetry of the unit cells of MgyTi100-y thin film alloys (with 70 to 90 at.% Mg) along the pressure composition isotherms at room temperature. The diffraction patterns show that the crystal structures of

  16. Analysis of seismic reflectivity and AVO pattern of BSR using OBS data in the southwestern offshore region of Taiwan

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, W.B.; Yang, H.R. [Jinwen Univ. of Science and Technology, Hsintien City, Taipei County, Taiwan (China). Dept. of Environment and Property Management; Schnurle, P.; Liu, C.S. [National Taiwan Univ., Taipei, Taiwan (China). Inst. of Oceanography; Lee, C.S. [National Taiwan Ocean Univ., Keelung, Taiwan (China). Inst. of Applied Earth Science; Wang, Y.; Chung, S.H.; Chen, S.C. [Ministry of Economic Affairs, Taiwan (China). Central Geological Survey

    2008-07-01

    Regional multi-channel seismic reflection profiles that were conducted in Taiwan from 2003 to 2006 resulted in the identification of a gas hydrate-related bottom simulating reflector (BSR) in the broad southwestern offshore region of Taiwan. In order to understand the regional distribution of methane hydrate bearing layers and explore concentrated hydrate bearing layers, this paper presented a comprehensive analysis of reflection coefficient and amplitude-versus-offset (AVO) pattern of BSR using ocean bottom seismographs (OBSs) seismic data acquired in the southwestern offshore region of Taiwan. The study focused on the analysis and interpretation of airgun array signals recorded by OBSs during 2004 and 2006. Ten profiles of seismic reflection/refraction with a total length of about 140 km and recorded by 50 recovered OBSs were acquired on the active and passive margins in offshore southwestern Taiwan. Amplitudes of the direct water arrival, the multiple, and the BSR were picked interactively for all the OBS lines. A quantitative representation of reflector strength was provided by calculation of reflection coefficients. In general, the seafloor reflection coefficients for the active and passive margins were estimated as 0.1-0.25. The paper presented the data and analysis as well as the results of the study. It was concluded that the results of calculated reflection coefficient of the BSR in offshore southwest Taiwan suggested that inferred hydrate concentration for the passive margin profiles was relatively higher than that for the active margin profiles. 4 refs.

  17. Simulation of MGI efficiency for plasma energy conversion into Ar radiation in JET and implications for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Pestchanyi, Serguei, E-mail: serguei.pestchanyi@kit.edu [Association EURATOM-KIT, Karlsruhe (Germany); Koslowski, Rudi; Reux, Cedric [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Lehnen, Michael [Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2015-10-15

    Highlights: • We simulated disruption mitigation using massive gas injection with the TOKES code. • Cross-reference analysis of JET experiments on MGI and their simulations have been done. • The analysis allows suggesting the mechanism for saturation of radiated energy fraction at 70–80%. • Rough extrapolation of the result on ITER conditions has been done. - Abstract: Effectiveness of massive gas injection (MGI) for mitigation of disruptive wall damage has been investigated. Cross-reference analysis of the available JET experiments on MGI and their simulations with the TOKES code allow suggesting that in JET conditions one can convert into radiation the electron thermal energy and the plasma current energy, but the ion thermal energy does not convert into radiation because of very ineffective excitation of injected noble gas (NG) ions by D ions and long equipartition time between D ions and electrons. The model assumes rather high electron temperature during current quench (CQ), which contradicts with its time duration. Rough extrapolation of the result on ITER conditions shows that one can expect irradiation of total plasma energy if CQ duration in ITER is not shorter as in JET.

  18. Iodide-conducting polymer electrolytes based on poly-ethylene glycol and MgI2: Synthesis and structural characterization

    International Nuclear Information System (INIS)

    Vittadello, Michele; Waxman, David I.; Sideris, Paul J.; Gan Zhehong; Vezzù, Keti; Negro, Enrico; Safari, Ahmad; Greenbaum, Steve G.; Di Noto, Vito

    2011-01-01

    A major obstacle for a viable technological development of dye sensitized solar cells (DSSCs) is still the synthesis of a high performance iodide-conducting polymer electrolyte. Here we present a series of eight electrolytic complexes with formula PEG1000/(MgI 2 ) x (I 2 ) y (0.0038 ≤ x ≤ 0.5801, 0 ≤ y ≤ 0.0636). The synthesis involves the preparation of a disordered form of MgI 2 by a metallorganic route, which enables us to dissolve high amounts of salt in the chosen polymer host. The thermal analysis of the resulting polymer electrolytes was performed using modulated differential scanning calorimetry measurements. Vibrational studies were carried out using medium FT-IR, far FT-IR and FT-Raman. The variation of the CO and OH stretching modes in the medium infrared, as a function of the mole-to-mole ratio n Mg /n O , was investigated by Gaussian decomposition to provide insight into the polymer–polymer and salt–polymer interactions in these materials. The FT-Raman spectra confirmed and complemented the vibrational assignment. The conductivity study of these systems was performed by electrical spectroscopy in the frequency interval 10 mHz–10 MHz. The direct current conductivity (σ DC ) profiles versus the reciprocal temperature exhibited a Vögel-Tamman-Fülcher (VTF) behavior. The best σ DC at 50 °C was 5 × 10 −5 S cm −1 . The overall results indicate the presence of bivalent, monovalent and neutral species, Mg 2+ , [MgI] + and MgI 2 , respectively, which participate in the conduction process. These results are consistent with what was previously observed in PEG400-based systems doped with δ-MgCl 2 . The presence of at least one Mg site containing a distribution in parameters was observed using 25 Mg solid state magic angle spinning nuclear magnetic resonance (MAS NMR) spectroscopy. The site has been assigned to a Mg complex involving the coordination by oxygen atoms of the polymer backbone.

  19. A > 4 MGy radiation tolerant 8 THzOhm transimpedance amplifier with 50 dB dynamic range

    International Nuclear Information System (INIS)

    Verbeeck, J; Steyaert, M; Leroux, P

    2013-01-01

    A 130 nm Transimpedance Amplifier has been developed with a 255 MHz bandwidth, 90 dBΩ transimpedance gain and a dynamic input range of 1:325 or 50 dB for a photo-diode capacitance of 0.75 pF. The equivalent integrated input noise is 160 nA - 25°C. The gain of the voltage amplifier, used in the transimpedance amplifier (TIA), degrades less than 3% over a temperature range from -40 °C up to 125 °C. The TIA and attenuator exhibit a radiation tolerance larger than 4 MGy, as evidenced by radiation assessment.

  20. Immuno-enhancement in tumor-bearing mice induced by whole body X-irradiation with 75 mGy

    International Nuclear Information System (INIS)

    Zhang Ying; Li Xiuyi; Gong Shouliang; Liu Shuzheng

    2000-01-01

    Objective: In present study the authors observed the effect of whole body irradiation (WBI) with 75 mGy X-rays on the immune function of tumor-bearing mice. Methods: Lewis lung carcinoma cells were implanted into the right thigh muscle of C57BL/6J mice. Ten days after tumor implantation, the tumor-bearing mice were administrated with 75 mGy X-rays WBI, then the mice were sacrificed 18 h after irradiation to detect the immune parameters including the spontaneous proliferation of thymocytes, the proliferative response of splenocytes to ConA and LPS, the cytotoxic activities of specific cytotoxic lymphocytes (CTL) and natural killer cells (NK), as well as lymphokine activated killer cells (LAK) in spleen. The methods the authors used were 3 H-TdR incorporation or release assay. Results: the immune parameters of exposed tumor-bearing mice were much higher than those of sham-irradiated tumor-bearing mice (P<0.01). Conclusion: These results suggested that low dose radiation (LDR) could enhance the immune function of tumor-bearing mice, which might be of practical significance in the prevention and therapy of cancer

  1. Design of a MGy radiation tolerant resolver-to-digital convertor IC for remotely operated maintenance in harsh environments

    Energy Technology Data Exchange (ETDEWEB)

    Leroux, Paul, E-mail: paul.leroux@kuleuven.be [KU Leuven, Dept. of Electrical Engineering (ESAT), AdvISe, Kleinhoefstraat 4, 2440 Geel (Belgium); Van Koeckhoven, Wesley; Verbeeck, Jens [KU Leuven, Dept. of Electrical Engineering (ESAT), AdvISe, Kleinhoefstraat 4, 2440 Geel (Belgium); Van Uffelen, Marco; Esqué, Salvador; Ranz, Roberto; Damiani, Carlo [Fusion for Energy, Torres Diagonal Litoral B3, Josep Pla 2, 08019 Barcelona (Spain); Hamilton, David [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France)

    2014-10-15

    During future ITER maintenance operations, sensors and their embarked electronics will be exposed to a hostile and radioactive environment. This paper presents the design of a MGy radiation tolerant 16 bit resolver-to-digital converter (RDC) in 130 nm CMOS technology. The RDC features a Type II digital tracking loop, able to track resolvers with speeds up to 300 rps, and excitation frequencies up to 4 kHz. The RDC uses two integrated ΔΣ-analog-to-digital converters (ADCs) to digitize the resolver outputs. The 16 bit, 10 kHz ADCs utilize a correlated double sampling technique to remove radiation induced offset and 1/f-noise. The front-end features a static angular resolution of 16 bits (4.2 arcsec{sub rms}) and a resolution of 10 bits (6 arcmin{sub rms}) at a rotor speed of 100 rps. The circuit has a simulated radiation tolerance exceeding 1 MGy. It has the ability to operate under temperatures up to 125 °C, and to allow multiplexing with signals from other conventional sensors for compact, robust read-out architectures.

  2. Synthesis and characterization of BaxMgyAl2O4: Eu,Dy nanophosphors prepared using solution-combustion method

    CSIR Research Space (South Africa)

    Kebede, MA

    2011-07-01

    Full Text Available Europium-doped barium magnesium aluminate (BaxMgyAl2O4:Eu) phosphors were obtained at low temperature using the solution-combustion of corresponding metal nitrate-urea solution mixtures. The particle sizes, morphology, structural and luminescent...

  3. Kodumaine mood kolib kaubanduskeskustesse / Karilin Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Karilin

    2010-01-01

    Tallinnas Stockmanni kaubamajas müüakse kuu aja jooksul eesti moekunstnike rõivakollektsioone. Projekti juhib Oksana Tandit. Kristiine keskuse Moetäikal müüvad eesti disainerid taaskasutatud riideid ning ReUse Republicu disainilaadal vanadest laoülejääkidest õmmeldud rõivaid

  4. Enkele etiese aspekte van natuurbewaring | Engelbrecht | HTS ...

    African Journals Online (AJOL)

    Certain ethical aspects of nature conservation The present worldwide ecocrisis is of such a magnitude and seriousness that man's life, living standards, future and very existence on earth are at stake. The main components of this man-made ecocrisis are the existing increasing overpopulation of earth, the exorbitant ...

  5. Beautiful dynamics / Jüri Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Jüri, 1939-

    2004-01-01

    1995. aastal tähistati füüsika alase teadusliku artikli, mis kirjeldab teatud tüüpi statsionaarset lainet ja pani aluse solitoonikale, 100. aastapäeva. Varem ilmunud: Proc. Estonian Acad. Sci. Phys. Math., 1995, 44, 1.

  6. Jaapani anime vallutab kinosaale / Karilin Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Karilin

    2008-01-01

    Jaapani anime filmidest (seekord peamiselt Ghibli stuudio omad), mida saab näha 4.-13. aprillini Tallinnas Sõpruse kinos ja 5.-10. aprillini Tartus Athena keskuses II Jaapani animefilmide festivalil JAFF. Lisatud tänane kava Tallinnas ja Tartus ning "Väike sõnastik"

  7. Getter Jaani osaleb nukuteatri muusikalis / Karilin Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Karilin

    2009-01-01

    2010. aasta kevadel jõuab nukuteatri lavale Walt Disney menufilmi "High School Musical" samanimeline muusikal kohalike lauljate esituses. Tüdrukutest peetakse suurimaks favoriidiks Getter Jaanit. Muusikali lavastab Andres Dvinjaninov

  8. Teologie en ekologie | Engelbrecht | HTS Teologiese Studies ...

    African Journals Online (AJOL)

    Theology and ecology. Ecology is a term traditionally used in the biological sciences. The word 'ecology' used in this sense means the science which studies the relation of living organisms (usually plants and animals) with their environment and the resultant life patterns. Changes in the environment result in changes of the ...

  9. Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

    International Nuclear Information System (INIS)

    Cao, Y.; Leroux, P.; De Cock, W.; Steyaert, M.

    2011-01-01

    Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma (ΔΣ) TDC structure is proposed. The converter, implemented in 0.13 μm, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm 2 . Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g m biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

  10. Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Y. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium); SCK.CEN, Belgian Nuclear Research Centre, B-2400 Mol (Belgium); Leroux, P. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium); ICT-RELIC Div., Katholieke Hogeschool Kempen, B-2440 Geel (Belgium); De Cock, W. [SCK.CEN, Belgian Nuclear Research Centre, B-2400 Mol (Belgium); Steyaert, M. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium)

    2011-07-01

    Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma ({Delta}{Sigma}) TDC structure is proposed. The converter, implemented in 0.13 {mu}m, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm{sup 2}. Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g{sub m} biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

  11. Generalized component analysis applied to the generation of seismic attributes for AVO and 4D reservoir interpretations; Mise au point d'attributs sismiques pour l'interpretation AVO et 4D des reservoirs petroliers par analyse en composantes generalisee

    Energy Technology Data Exchange (ETDEWEB)

    Voutay, O.

    2003-02-01

    Seismic data contain further geological information than well, due to their good spatial extent. But the seismic measure is band pass limited and the contrasts in acoustic or elastic properties derived from seismic are not directly linked to the reservoir properties. Thus, it is difficult to give a geological interpretation to seismic data. Basically, relevant seismic attributes are extracted at the reservoir level, and then are calibrated with information available at wells by using pattern recognition and statistical estimation techniques. These methods are successfully used in the post-stack domain. But, for multi-cube seismic information such as pre-stack or 4D data, the number of attributes can considerably increase and statistical methods are not often used. It is necessary to find a parameterization allowing an optimal description the seismic variability in the time window of interest. We propose to extract new attributes from seismic multi-cube data with Generalised Principal Analysis and to use them for reservoir interpretation with statistical techniques. The new attributes can be clearly related to the initial data set, and then be physically interpreted, while optimally summarizing the initial seismic information. By applying the Generalised Principal Analysis to 3D pre-stack surveys, the contribution of the pre-stack seismic information to reservoir characterisation is compared to the post-stack seismic one, in both synthetic and real cases. By applying the Generalised Principal Analysis to real 4D surveys, the seismic repeatability is quantified and the seismic changes in the reservoir with calendar time are highlighted and interpreted. A coherency cube has also been defined, based on the Generalised Principal Analysis. This attribute is a coherence measurement in three dimensions representing the local similarity between 4D or AVO surveys. (author)

  12. Total body 100-mGy X-irradiation does not induce Alzheimer's disease-like pathogenesis or memory impairment in mice

    International Nuclear Information System (INIS)

    Wang, Bing; Tanaka, Kaoru; Ji, Bin

    2014-01-01

    The cause and progression of Alzheimer's disease (AD) are poorly understood. Possible cognitive and behavioral consequences induced by low-dose radiation are important because humans are exposed to ionizing radiation from various sources. Early transcriptional response in murine brain to low-dose X-rays (100 mGy) has been reported, suggesting alterations of molecular networks and pathways associated with cognitive functions, advanced aging and AD. To investigate acute and late transcriptional, pathological and cognitive consequences of low-dose radiation, we applied an acute dose of 100-mGy total body irradiation (TBI) with X-rays to C57BL/6J Jms mice. We collected hippocampi and analyzed expression of 84 AD-related genes. Mouse learning ability and memory were assessed with the Morris water maze test. We performed in vivo PET scans with 11 C-PIB, a radiolabeled ligand for amyloid imaging, to detect fibrillary amyloid beta peptide (Aβ) accumulation, and examined characteristic AD pathologies with immunohistochemical staining of amyloid precursor protein (APP), Aβ, tau and phosphorylated tau (p-tau). mRNA studies showed significant downregulation of only two of 84 AD-related genes, Apbb1 and Lrp1, at 4 h after irradiation, and of only one gene, Il1α, at 1 year after irradiation. Spatial learning ability and memory were not significantly affected at 1 or 2 years after irradiation. No induction of amyloid fibrillogenesis or changes in APP, Aβ, tau, or p-tau expression was detected at 4 months or 2 years after irradiation. TBI induced early or late transcriptional alteration in only a few AD-related genes but did not significantly affect spatial learning, memory or AD-like pathological change in mice. (author)

  13. Optimal conditions of LDR to protect the kidney from diabetes: exposure to 12.5 mGy X-rays for 8 weeks efficiently protects the kidney from diabetes.

    Science.gov (United States)

    Cheng, Jie; Li, Fengsheng; Cui, Jiuwei; Guo, Weiying; Li, Cai; Li, Wei; Wang, Guixia; Xing, Xiao; Gao, Ying; Ge, Yuanyuan; Wang, Guanjun; Cai, Lu

    2014-05-08

    We reported the attenuation of diabetes-induced renal dysfunction by exposure to multiple low-dose radiation (LDR) at 25 mGy every other day by suppressing renal oxidative damage. We here explored the optimal conditions of LDR to protect the kidney from diabetes. Male C57BL/6J mice with type 1 diabetes were induced with multiple injections of low-dose streptozotocin. Diabetic mice received whole body X-irradiation at a dose of 12.5, 25 or 50 mGy every other day for either 4 or 8 weeks. Age-matched normal mice were similarly irradiated at the dose of 25 mGy for 4 or 8 weeks. The renal function and histopathological changes were examined at the 4th and 8th weeks of the study. Diabetes induced renal dysfunction is shown by the decreased creatinine and increased microalbumin in the urine. Renal oxidative damage, detected by protein nitration and lipid oxidation, and remodeling, reflected by increased expression of connective tissue growth factor, collagen IV and fibronectin, were significantly increased in diabetic mice. All these renal pathological and function changes in diabetic mice were significantly attenuated by exposure to LDR at all regimens, among which, however, exposure to LDR at 12.5 mGy for 8 weeks provided the best protective effect on the kidney of diabetic mice. Our results suggest that whole-body LDR at 12.5 mGy every other day for 8 weeks is the optimal condition of LDR to protect the kidney from diabetes. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. From nGy to MGy - new TL dosimetry of complex radiation at high-energy accelerators and thermonuclear fusion facilities

    International Nuclear Information System (INIS)

    Obryk, B.; Bilski, P.; Budzanowski, M.; Olko, P.

    2011-01-01

    One of the well known advantages of thermoluminescence (TL) detectors made of lithium fluoride doped with magnesium, copper and phosphorus (LiF:Mg,Cu,P) is their very high sensitivity to ionizing radiation. LiF:Mg,Cu,P detectors enable measurements of radiation doses from tens of nano grays up to a few kilo grays, when the total saturation of the signal of the so-called main dosimetric peak (at about 220 C. degrees) occurs. In 2006 for the first time we observed unprecedented high-temperature emission of LiF detectors heated to temperatures up to 600 C. degrees, after exposures to radiation doses ranging from 1 kGy to 1 MGy. For quantification of the glow curve shape changes of LiF:Mg,Cu,P detectors in this range of doses and determination of the absorbed dose, the high temperature coefficient (UHTR) was defined. This newly established dosimetric method was tested in a range of radiation qualities, such as gamma radiation, electron and proton beams, thermal neutron fields and in high-energy mixed fields around the SPS and PS accelerators at CERN. A number of dosimetric sets with LiF:Mg,Cu,P detectors are currently installed around the LHC at CERN. The new method for ultra-high dose range monitoring with a single LiF:Mg,Cu,P detector, which is capable of covering at least twelve orders of magnitude of doses, can be used for dosimetry at high energy accelerators and has great potential for accident dosimetry in particular. (authors)

  15. Optimization of Monocrystalline MgxCd1-xTe/MgyCd1-yTe Double-Heterostructure Solar Cells

    Science.gov (United States)

    Becker, Jacob J.

    Polycrystalline CdS/CdTe solar cells continue to dominate the thin-film photovoltaics industry with an achieved record efficiency of over 22% demonstrated by First Solar, yet monocrystalline CdTe devices have received considerably less attention over the years. Monocrystalline CdTe double-heterostructure solar cells show great promise with respect to addressing the problem of low Voc with the passing of the 1 V benchmark. Rapid progress has been made in driving the efficiency in these devices ever closer to the record presently held by polycrystalline thin-films. This achievement is primarily due to the utilization of a remote p-n heterojunction in which the heavily doped contact materials, which are so problematic in terms of increasing non-radiative recombination inside the absorber, are moved outside of the CdTe double heterostructure with two MgyCd1-yTe barrier layers to provide confinement and passivation at the CdTe surfaces. Using this design, the pursuit and demonstration of efficiencies beyond 20% in CdTe solar cells is reported through the study and optimization of the structure barriers, contacts layers, and optical design. Further development of a wider bandgap MgxCd1-xTe solar cell based on the same design is included with the intention of applying this knowledge to the development of a tandem solar cell constructed on a silicon subcell. The exploration of different hole-contact materials--ZnTe, CuZnS, and a-Si:H--and their optimization is presented throughout the work. Devices utilizing a-Si:H hole contacts exhibit open-circuit voltages of up to 1.11 V, a maximum total-area efficiency of 18.5% measured under AM1.5G, and an active-area efficiency of 20.3% for CdTe absorber based devices. The achievement of voltages beyond 1.1V while still maintaining relatively high fill factors with no rollover, either before or after open-circuit, is a promising indicator that this approach can result in devices surpassing the 22% record set by polycrystalline

  16. Noored tantsivad tänavakultuuri / Karilin Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Karilin

    2008-01-01

    26. sept. Tallinnas algavast tänavatantsu festivalist JJ Street Baltic Session. Tantsufestivali korraldaja on Joel Juht, kes peab Eestis ainukest tänavatantsu õppekavaga kooli JJ Street Dance Company

  17. Why do male patients request circumcisions? | Engelbrecht | South ...

    African Journals Online (AJOL)

    Background: Circumcision has been performed for centuries. The popularity of the procedure waxed and waned during the ages. In South Africa, cultural circumcision is often regarded as the only way to attain full adulthood, and consequently many patients request circumcision by medical personnel. The aim of this study ...

  18. Bertmani allajäämine Prokofjevile / Karilin Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Karilin

    2010-01-01

    Los Angeleses toimunud 52. Grammy auhindade jagamisest, kuus auhinda pälvis laulja Beyonce. Kaasaegse klassikalise kompositsiooni kategoorias kandideerijate seas oli ka Arvo Pärt. Võitjate nimekiri

  19. From parts to whole / Jüri Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Jüri, 1939-

    2003-01-01

    Autor analüüsib Euroopa Akadeemiate Ühenduse ALLEA poolt EL-i liikmes- ja kandidaatriikides läbi viidud uuringutele tuginedes olemasolevaid rahvuslikke teadusstrateegiaid, peatub pikemalt Eesti teaduspoliitikal ja pakub võimalikke lahendusi Euroopa ühtse teaduspoliitika väljatöötamiseks

  20. Pyott Case: A Lasting Deposit for Our Tax Heritage | Engelbrecht ...

    African Journals Online (AJOL)

    Pyott Ltd v CIR is generally regarded as the seminal case in South Africa on the tax treatment of deposits received on containers that may be returned at a later stage for a refund. This article analyses the tax treatment of deposits, prepayments and advances from a gross income point of view, as well as the possibility of ...

  1. Very low-dose (0.15 mGy) chest CT protocols using the COPDGene 2 test object and a third-generation dual-source CT scanner with corresponding third-generation iterative reconstruction software.

    Science.gov (United States)

    Newell, John D; Fuld, Matthew K; Allmendinger, Thomas; Sieren, Jered P; Chan, Kung-Sik; Guo, Junfeng; Hoffman, Eric A

    2015-01-01

    The purpose of this study was to evaluate the impact of ultralow radiation dose single-energy computed tomographic (CT) acquisitions with Sn prefiltration and third-generation iterative reconstruction on density-based quantitative measures of growing interest in phenotyping pulmonary disease. The effects of both decreasing dose and different body habitus on the accuracy of the mean CT attenuation measurements and the level of image noise (SD) were evaluated using the COPDGene 2 test object, containing 8 different materials of interest ranging from air to acrylic and including various density foams. A third-generation dual-source multidetector CT scanner (Siemens SOMATOM FORCE; Siemens Healthcare AG, Erlangen, Germany) running advanced modeled iterative reconstruction (ADMIRE) software (Siemens Healthcare AG) was used.We used normal and very large body habitus rings at dose levels varying from 1.5 to 0.15 mGy using a spectral-shaped (0.6-mm Sn) tube output of 100 kV(p). Three CT scans were obtained at each dose level using both rings. Regions of interest for each material in the test object scans were automatically extracted. The Hounsfield unit values of each material using weighted filtered back projection (WFBP) at 1.5 mGy was used as the reference value to evaluate shifts in CT attenuation at lower dose levels using either WFBP or ADMIRE. Statistical analysis included basic statistics, Welch t tests, multivariable covariant model using the F test to assess the significance of the explanatory (independent) variables on the response (dependent) variable, and CT mean attenuation, in the multivariable covariant model including reconstruction method. Multivariable regression analysis of the mean CT attenuation values showed a significant difference with decreasing dose between ADMIRE and WFBP. The ADMIRE has reduced noise and more stable CT attenuation compared with WFBP. There was a strong effect on the mean CT attenuation values of the scanned materials for ring

  2. Qualification method for a 1 MGy-tolerant front-end chip designed in 65 nm CMOS for the read-out of remotely operated sensors and actuators during maintenance in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Verbeeck, Jens, E-mail: jens.verbeeck@esat.kuleuven.be [KU Leuven (KUL), Div. LRD-MAGyICS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Cao, Ying [KU Leuven (KUL), Div. LRD-MAGyICS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Van Uffelen, Marco; Casellas, Laura Mont; Damiani, Carlo; Morales, Emilio Ruiz; Santana, Roberto Ranz [Fusion for Energy (F4E), c/Josep, no. 2, Torres Diagonal Litoral, Ed. B3, 08019 Barcelona (Spain); Meek, Richard; Haist, Bernhard [Oxford Technologies Ltd. (OTL), 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); Hamilton, David [ITER Organisation (IO), Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul les Durance Cedex (France); Steyaert, Michiel [KU Leuven, ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Leroux, Paul [KU Leuven, ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); KU Leuven, ESAT, Advanced Integrated Sensing Lab (AdvISe), Kleinhoefstraat 4, 2440 Geel (Belgium)

    2015-10-15

    This paper describes the radiation qualification procedure for a 1 MGy-tolerant Application Specific Integrated Circuit (ASIC) developed in 65 nm CMOS technology. The chip is intended for the read-out of electrical signals of sensors and actuators during maintenance in ITER. First the general working principle of the ASIC is shown. The developed IC allows to read-out, condition and digitize multiple low bandwidth (<10 kHz) sensors. In addition the IC is able to multiplex the digitized sensor signals. To comply with ITER-relevant constraints an adapted radiation qualification procedure has been proposed. The radiation-qualification procedure describes the test criteria and test conditions of the developed ASICs, which are also compared with COTS alternatives, to meet the stringent qualification procedures for electronics exposed to radiation in ITER.

  3. As-Deposited (La1-xSrx)(Ga1-y-zMgyCoz)O3-(x+y+z)/2 Crystallized Thin Films Prepared by Pulsed Laser Deposition for Application to Solid Oxide Fuel Cell Electrolyte

    Science.gov (United States)

    Mitsugi, Fumiaki; Kanazawa, Seiji; Ohkubo, Toshikazu; Nomoto, Yukiharu; Ishihara, Tatsumi; Takita, Yusaku

    2004-01-01

    Doped lanthanum gallate (La1-xSrx)(Ga1-y-zMgyCoz)O3-(x+y+z)/2 (LSGMCO) perovskite oxide films were deposited on a quartz glass, LaAlO3 single-crystal substrate and porous anode electrode of a solid oxide fuel cell (SOFC) by pulsed laser deposition. It was necessary to increase the substrate temperature up to 800°C for a crystallization of the LSGMCO films. The film deposited on the LaAlO3 single-crystal substrate grew along the c-axis. The as-deposited LSGMCO thick film fabricated on the porous substrate at 800°C and at an oxygen pressure of 20Pa was formed from polycrystal columns and showed a high conductivity of 0.7S/cm at a measurement temperature of 800°C. The activation energies were 0.72 eV at 600-800°C and 1.05 eV at 400-600°C.

  4. Specific considerations for obtaining appropriate La1-xSrxGa1-yMgyO3-δ thin films using pulsed-laser deposition and its influence on the performance of solid-oxide fuel cells

    Science.gov (United States)

    Hwang, Jaeyeon; Lee, Heon; Lee, Jong-Ho; Yoon, Kyung Joong; Kim, Hyoungchul; Hong, Jongsup; Son, Ji-Won

    2015-01-01

    To obtain La1-xSrxGa1-yMgyO3-δ (LSGM) thin films with the appropriate properties, pulsed-laser deposition (PLD) is employed, and specific considerations regarding control of the deposition parameters is investigated. It is demonstrated that with a target of stoichiometric composition, appropriate LSGM thin films cannot be produced because of the deviation of the composition from the target to the thin film. Only after adjusting the target composition an LSGM thin film with an appropriate composition and phase can be obtained. The optimized LSGM thin film possesses an electrical conductivity close to that of the bulk LSGM. In contrast, non-optimized thin films do not yield any measurable electrical conductivity. The impact of the optimization of the LSGM thin-film electrolyte on the cell performance is quite significant, in that a solid-oxide fuel cell (SOFC) with an optimized LSGM thin-film electrolyte produces a maximum power density of 1.1 W cm-2 at 600 °C, whereas an SOFC with a non-optimal LSGM thin-film electrolyte is not operable.

  5. Mis seal teletornis siis tegelikult juhtus? / Avo-Rein Tereping

    Index Scriptorium Estoniae

    Tereping, Avo-Rein, 1945-

    2005-01-01

    Eesti Raadio endine tehnikadirektor kirjeldab 1991. aastal augustiputshi päevil teletornis toimunut ning rõhutab, et ei tohi unustada neid tehnilisi töötajaid, kes päästsid teletorni aparatuuri hävingust ning lõid alternatiivsed infokanalid. Ka Ilmar Raagi lavastatud Eesti Televisiooni fiktiivsest dokumentaaldraamast "August 1991"

  6. Vana hea tuttav korruptsioon / Avo Üprus

    Index Scriptorium Estoniae

    Üprus, Avo, 1954-

    2004-01-01

    Ilmunud ka: Meie Maa, 25. aug. 2004, lk. 2; Nädaline, 26. aug. 2004, lk. 4; Järva Teataja, 26. aug. 2004, lk. 2; Koit, 26. aug. 2004, lk. 6; Põhjarannik, 26. aug. 2004, lk. 2; Severnoje Poberezhje, 26. aug. 2004, lk. 2; Harjumaa, 27. aug. 2004, lk. 2; Valgamaalane, 28. aug. 2004, lk. 2; Pärnu Postimees, 3. sept. 2004, lk. 15; Vali Uudised, 3. sept. 2004, lk. 2. Vastukaja Viktor Vassiljevi artiklitele 19. juuli ja 17. aug. Postimehes

  7. Wat is die reg en die vryheid van die eksegeet? | Engelbrecht | HTS ...

    African Journals Online (AJOL)

    The theological criticism tries to bridge this gap and amongst others to give due weight to the fact that the Bible, human in form and content, is simultaneously Word of God. This article proceeds to discuss the various phases in the exegetic process and their connection with (and limitation by - if any) the church-dogma.

  8. Kerklike tug volgens 1 Korintiërs 5 en 6 | Engelbrecht | HTS ...

    African Journals Online (AJOL)

    ... already are, and for the ultimate benefit of the offenders, ecclesiastical discipline should be applied by this community of believers. The principle is put clear by Paul, but how should it be put into practice in present day circumstances and in each individual case? Do these chapters have any relevance for today's church?

  9. Tallinn Fashion Week täidab nädala kodumaise moega / Karilin Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Karilin

    2009-01-01

    Tallinn Fashion Week'i üritustest. Ülevaade eesti moekunstnike loomingu esitlustest. Näitus "Uus Eesti moejoonistus" Arhitektuuri- ja Disainigaleriis. Anu Hindi moefotonäitus "Aeg maha 3" Iida galeriis. Raamatu "Eesti moepiibel 2010" esitlus Rotermanni kvartali kohvikus Platz. Oksana Tanditi ja Filippo Caroti moefotonäitus "Butterflies" Tallinna botaanikaaias

  10. In situ X-ray and neutron diffraction of the Ruddlesden-Popper compounds (RE2-xSrx)0.98(Fe0.8Co0.2)1-yMgyO4-δ (RE=La, Pr): Structure and CO2 stability

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Hauback, B.C.; Hendriksen, Peter Vang

    2013-01-01

    The crystal structure of the Ruddlesden-Popper compounds (La 1.0Sr1.0)0.98Fe0.8Co 0.2O4-δ and (La1.2Sr0.8) 0.98(Fe0.8Co0.2)0.8Mg 0.2O4-δ was investigated at 1000 °C in N 2 (aO2=1×10-4) by in-situ powder neutron diffraction. In-situ powder X-ray diffraction (PXD) was also employed to investigate....... The equivalent pseudo-cubic thermal and chemical expansion coefficients are in agreement with values determined by dilatometry. The chemical stability in CO2 containing environments of various Ruddlesden-Popper compounds with chemical formula (RE2-xSr x)0.98(Fe0.8Co0.2) 1-yMgyO4-δ (RE=La, Pr), as well...

  11. Teadmistepõhise ühiskonna võimalikkusest = Chancen einer wissensbasierten Gesellschaft / Jüri Engelbrecht

    Index Scriptorium Estoniae

    Engelbrecht, Jüri, 1939-

    2005-01-01

    Autori hinnangul haarab teaduse roll arenenud riikides üldist teadmiste kasvu kui alust heale haridusele, konkurentsivõimelisele majandusele, kultuurile selle laiemas tähenduses ning riigi kodanike teadlikkusele

  12. Uudised : Nikolai Aleksejev ERSO peadirigendiks. Lastemuusikalide festival. Hinnatud gospelkoor Eestis / Avo Suurvärav

    Index Scriptorium Estoniae

    Suurvärav, Avo

    2001-01-01

    15. märtsil allkirjastati ERSO uue peadirigendi N. Aleksejevi tööleping. 19.-21. märtsini Tallinnas toimunud I Eesti lastemuusikalide festivalist, osa võtnud lasteteatritest. 21. märtsil esines Tallinnas Londoni gospelkoor

  13. Uudised : Eesti esiettekandeid Eesti Filharmoonia Kammerkoorilt. Morgensterni muusikatunnid. Estonia operetisolistid Nõmmel / Avo Suurvärav

    Index Scriptorium Estoniae

    Suurvärav, Avo

    2001-01-01

    7. ja 9. apr. Tallinna Metodisti kirikus toimuvatest kontsertidest, kus on kavas A. Pärdi ja J. MacMillani teosed. 31. märtsil TÜ ajaloomuuseumis toimunud "Morgensterni muusikatunnist", kus L. Langsepp tutvustas ajaloolisi harfe. 30. märtsil etendus Nõmme kultuurikeskuses E. Künneke operett "Onupoeg Bataaviast"

  14. Säärane mulk, ehk sada vakka etteheiteid / Avo Üprus

    Index Scriptorium Estoniae

    Üprus, Avo, 1954-

    2004-01-01

    Ilmunud ka: Hiiumaa, 24. juuli 2004, lk. 2; Võrumaa Teataja, 24. juuli 2004, lk. 2; Vooremaa, 24. juuli 2004, lk. 2; Meie Maa, 23. juuli 2004, lk. 2; Järva Teataja, 27. juuli 2004, lk. 4; Lääne Elu, 27. juuli 2004, lk. 2; Koit, 27. juuli 2004, lk. 6; Pärnu Postimees, 28. juuli 2004, lk. 15; Virumaa Teataja, 30. juuli 2004, lk. 7; Vali Uudised, 30. juuli 2004, lk. 2; Põhjarannik, 30. juuli 2004, lk. 2; Severnoje Poberezhje, 30. juuli 2004, lk. 2; Hiiu Leht, 3. aug. 2004, lk. 2; Sakala, 3. aug. 2004, lk. 2; Valgamaalane, 12. aug. 2004, lk. 2. Vastuseks Helir-Valdor Seederi art. 17. juuli ajal. Meie Maa. Uus poliitika tähendab üldinimlike väärtuste taasväärtustamise kaudu pidevalt uuenevat riiki.

  15. Rein Oja, Kirsti Timmer ja Avo Põhjala võitluskunstidest / Simo Meinert

    Index Scriptorium Estoniae

    Meinert, Simo

    2001-01-01

    Seriaali "Walker - Texase korravalvur" nimitegelast mängiva Chuck Norrise võitluskunstide oskusi aluseks võttes arendatakse teemat idamaa võitluskunstidest kinos, teatris ja elus. Ka : Teleleht nr. 49, lk. 42-43

  16. G Genetic c chara acteris Mill.) in sation on two r of avo region ocado

    African Journals Online (AJOL)

    SAM

    zygosity (Hobs), for all populations were estimated using. PowerMarker version 3.25 (Liu and Muse, 2004). A phylogenetic tree was constructed for all 71 individuals genotyped following the. Unweighted Paired Group Method (UPGMA) (Sneath and Sokal,. 1973). Following this, dendrograms of genetic relationships among.

  17. Fluid prediction using rock modelling and reconnaissance. AVO analysis - A case study from the North Sea

    Energy Technology Data Exchange (ETDEWEB)

    Osdal, Bard; Granli, John Reidar

    1998-12-31

    Seismic lithology and fluid phase prediction (LFP) is becoming an important part of seismic interpretation, and can contribute significantly to risk reduction prior to drilling. In this presentation there is focused on quantitative interpretation of the amplitudes in a 2-D dataset, with respect to presence of hydrocarbons. Different aspect of the working producer, like data quality (well data and seismic data), rock modelling and seismic modelling will be illustrated. In the present study only one well has been used for calibration and to investigate the seismic response for different fluid and lithology scenarios. The rock modelling included evaluation of seismic parameter effect for different fluid and porosities. 1 ref., 4 figs.

  18. Lanthanide 4f-level location in AVO4:Ln3+ (A = La, Gd, Lu) crystals

    NARCIS (Netherlands)

    Krumpel, A.H.; Van der Kolk, E.; Cavalli, E.; Boutinaud, P.; Bettinelli, M.; Dorenbos, P.

    2009-01-01

    The spectral properties of LaVO4, GdVO4 and LuVO4 crystals doped with Ce3+, Pr3+, Eu3+ or Tb3+ have been investigated in order to determine the position of the energy levels relative to the valence and conduction bands of the hosts along the trivalent and divalent lanthanide series. Pr3+ and Tb3+

  19. On inferring the noise in probabilistic seismic AVO inversion using hierarchical Bayes

    DEFF Research Database (Denmark)

    Madsen, Rasmus Bødker; Zunino, Andrea; Hansen, Thomas Mejer

    2017-01-01

    A realistic noise model is essential for trustworthy inversion of geophysical data. Sometimes, as in case of seismic data, quan- tification of the noise model is non-trivial. To remedy this, a hierarchical Bayes approach can be adopted in which proper- ties of the noise model, such as the amplitude...... of an assumed uncorrelated Gaussian noise model, can be inferred as part of the inversion. Here we demonstrate how such an approach can lead to substantial overfitting of noise when inverting a 1D re- flection seismic NMO data set. We then argue that usually the noise model is correlated, and suggest to infer...

  20. On inferring the noise in probabilistic seismic AVO inversion using hierarchical Bayes

    OpenAIRE

    Madsen, Rasmus Bødker; Zunino, Andrea; Hansen, Thomas Mejer

    2017-01-01

    A realistic noise model is essential for trustworthy inversion of geophysical data. Sometimes, as in case of seismic data, quan- tification of the noise model is non-trivial. To remedy this, a hierarchical Bayes approach can be adopted in which proper- ties of the noise model, such as the amplitude of an assumed uncorrelated Gaussian noise model, can be inferred as part of the inversion. Here we demonstrate how such an approach can lead to substantial overfitting of noise when inverting a 1D ...

  1. Colour centres in LiF for measurement of abssorbed doses up to 100 MGy

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1996-01-01

    Radiation damage studies on electronic components, polymers, composites, ceramics, metals and insulating materials exposed to very large doses of ionising photons and particles (i.e. electrons, protons, and neutrons) require reproducible and accurate passive dosimetry. Absorbed doses in the range 10 2 -2 x 10 6 Gy have previously been measured with optical quality, undoped LiF by spectrophotometry of radiation-induced absorption bands of stable colour centres. These include the relatively stable F centre (247 nm), M centre (443 nm), R 1 centre (315 nm), R 2 centre (374 nm), and N 2 centre (547 nm). It is now possible to extend this range to 10 8 Gy by spectrophotometry of the N 1 centre (517 nm) and an 'X' centre (785 nm). These dosemeters can be used from cryogenic (4 K) to relatively high radiation temperatures (up to 500 K). The radiation-induced coloration can be bleached for re-use of the dosemeters by a two hour thermal annealing treatment at 830 K. (Author)

  2. Ductility improvement by twinning and twin–slip interaction in a Mg-Y alloy

    International Nuclear Information System (INIS)

    Zhou, Na; Zhang, Zhenyan; Jin, Li; Dong, Jie; Chen, Bin; Ding, Wenjiang

    2014-01-01

    Highlights: • A high elongation of ∼33% was achieved for magnesium alloy through common extrusion. • Basal slip and extension twinning are the dominant deformation modes for the high ductility. • Non-basal slip, contraction twinning and twin-slip interaction also contribute to the ductility. - Abstract: An extruded Mg-3.0Y alloy with non-basal texture of 〈42 ¯ 2 ¯ 3〉 component was fabricated by common extrusion and exhibited a high elongation of ∼33%. The deformation modes and microstructure evolution of the extruded Mg-3.0Y alloy during the tensile test at room temperature were investigated to explore the reasons for the high ductility by transmission electron microscopy (TEM) and electron backscattered diffraction (EBSD). The results suggested that texture changed from 〈42 ¯ 2 ¯ 3〉 to 〈101 ¯ 0〉 component during the tensile deformation, which is attributed the slip and twinning activity. Basal slip and extension twinning are the dominant deformation modes for the high ductility. Meanwhile, the activation of non-basal slip, contraction twinning and twin–slip interaction also contributes to the good ductility of Mg-3.0Y alloy

  3. MGI-oriented High-throughput Measurement of Interdiffusion Coefficient Matrices in Ni-based Superalloys

    Directory of Open Access Journals (Sweden)

    TANG Ying

    2017-01-01

    Full Text Available One of the research hotspots in the field of high-temperature alloys was to search the substitutional elements for Re in order to prepare the single-crystal Ni-based superalloys with less or even no Re addition. To find the elements with similar or even lower diffusion coefficients in comparison with that of Re was one of the effective strategies. In multicomponent alloys, the interdiffusivity matrix were used to comprehensively characterize the diffusion ability of any alloying elements. Therefore, accurate determination of the composition-dependant and temperature-dependent interdiffusivities matrices of different elements in γ and γ' phases of Ni-based superalloys was high priority. The paper briefly introduces of the status of the interdiffusivity matrices determination in Ni-based superalloys, and the methods for determining the interdiffusivities in multicomponent alloys, including the traditional Matano-Kirkaldy method and recently proposed numerical inverse method. Because the traditional Matano-Kirkaldy method is of low efficiency, the experimental reports on interdiffusivity matrices in ternary and higher order sub-systems of the Ni-based superalloys were very scarce in the literature. While the numerical inverse method newly proposed in our research group based on Fick's second law can be utilized for high-throughput measurement of accurate interdiffusivity matrices in alloys with any number of components. After that, the successful application of the numerical inverse method in the high-throughput measurement of interdiffusivity matrices in alloys is demonstrated in fcc (γ phase of the ternary Ni-Al-Ta system. Moreover, the validation of the resulting composition-dependant and temperature-dependent interdiffusivity matrices is also comprehensively made. Then, this paper summarizes the recent progress in the measurement of interdiffusivity matrices in γ and γ' phases of a series of core ternary Ni-based superalloys achieved in our research group. Up to now, the interdiffusivity matrices in γ and γ' phases of the core ternary systems including Ni-Al-X (X=Rh, Ta, W, Re, Os and Ir have been efficiently measured, and their reliability has also been carefully validated. Based on the experimental results, the interdiffusivities for different elements in Ni-based superalloys are carefully compared, from which the potential substitutional alloying elements for Re in Ni-based supperalloys as well as the points for alloy composition design are proposed. Finally, the research work of next step on the measurement of interdiffusivity matrices in Ni-based superalloys as well as the development trends of high-throughput measurement of interdiffusivities in our research group are pointed out.

  4. Velocity and AVO analysis for the investigation of gas hydrate along a profile in the western continental margin

    Digital Repository Service at National Institute of Oceanography (India)

    Dewangan, P.; Ramprasad, T.

    The occurrence of gas hydrate has been inferred from the presence of Bottom-Simulating Reflectors (BSRs) along the western continental margin of India. In this paper, we assess the spatial and vertical distribution of gas hydrates by analyzing...

  5. Toetusrühm on toetuseks ehk maalitud seinast, kuldvõtmekesest ja tegelikust elust / Avo Üprus

    Index Scriptorium Estoniae

    Üprus, Avo, 1954-

    2005-01-01

    Autor leiab, et valitsus saab juhtida oma programme ka kodanikeühenduste koostöövõrgu kaudu ning lihtsustada nii riigi ülesehitust. Muutuvas maailmas võib kaasamise kaudu kasvatada usaldust ja vastutust

  6. Estimation of changes in saturation and pressure from 4D seismic AVO and time-shift analysis

    NARCIS (Netherlands)

    Trani, M.; Arts, R.; Leeuwenburgh, O.; Brouwer, J.

    2011-01-01

    A reliable estimate of reservoir pressure and fluid saturation changes from time-lapse seismic data is difficult to obtain. Existing methods generally suffer from leakage between the estimated parameters. We propose a new method using different combinations of time-lapse seismic attributes based on

  7. Photoluminescence, modulation spectroscopy and surface photovoltage characterization of quaternary Zn1-x-yCdxMgySe compounds

    International Nuclear Information System (INIS)

    Dumcenco, D.O.; Levcenco, S.V.; Huang, Y.S.; Firszt, F.; Hsu, H.P.; Tiong, K.K.

    2011-01-01

    An optical characterization of wurtzite Zn 1-x-y Cd x Mg y Se crystalline alloys grown by the modified high-pressure Bridgman method has been carried out by temperature-dependent photoluminescence (PL) and contactless electroreflectance (CER) in the temperature range of 10-300 K, and photoreflectance (PR) measurements between 300-400 K as well as surface photovoltage spectroscopy (SPS) at 300 K. Low temperature PL spectra of the investigated samples consist of an excitonic line, the 'edge emission' due to radiative recombination of shallow donor-acceptor pairs and a broad band related to recombination through deep level defects. Three excitonic features, A, B and C, in the vicinity of band edge were observed in the CER and PR spectra. The peak positions of band-edge excitonic features in the PL spectra are shifted slightly towards lower energies as compared to the lowest corresponding transition energies of A exciton determined from CER and PR data. The increase of the CER-PL shift with the increasing of Mg content in the investigated crystals is explained by the rising of compositional disorder causing the smearing of the band-edge energies. In addition, the coincidence of energy positions of features obtained from SPS measurements with excitonic transition energies E 0 A determined from CER/PR data at 300 K confirm the proper surface treatment of the samples. (authors)

  8. Global radiation damage at 300 and 260 K with dose rates approaching 1 MGy s{sup −1}

    Energy Technology Data Exchange (ETDEWEB)

    Warkentin, Matthew; Badeau, Ryan; Hopkins, Jesse B. [Cornell University, Ithaca, NY 14853 (United States); Mulichak, Anne M.; Keefe, Lisa J. [Argonne National Laboratory, Argonne, IL 60439 (United States); Thorne, Robert E., E-mail: ret6@cornell.edu [Cornell University, Ithaca, NY 14853 (United States)

    2012-02-01

    Approximately half of global radiation damage to thaumatin crystals can be outrun at 260 K if data are collected in less than 1 s. Global radiation damage to 19 thaumatin crystals has been measured using dose rates from 3 to 680 kGy s{sup −1}. At room temperature damage per unit dose appears to be roughly independent of dose rate, suggesting that the timescales for important damage processes are less than ∼1 s. However, at T = 260 K approximately half of the global damage manifested at dose rates of ∼10 kGy s{sup −1} can be outrun by collecting data at 680 kGy s{sup −1}. Appreciable sample-to-sample variability in global radiation sensitivity at fixed dose rate is observed. This variability cannot be accounted for by errors in dose calculation, crystal slippage or the size of the data sets in the assay.

  9. Raman scattering in three-cation diluted magnetic semiconductor Cd1-x-yMnxMgyTe

    International Nuclear Information System (INIS)

    Agekyan, V.F.; Gridneva, L.K.; Karpov, S.V.; Serov, A.Yu.

    1995-01-01

    Investigations of Raman scattering (RS) in quaternary compounds were conducted to determine and interpret LO and TO frequencies, characterizing CdTe, MnTe, MgTe components in mixed crystal. Raman spectrum in the range of low frequencies is interpreted as interaction of quasi local vibrations with acoustic continuum

  10. Ühiseid väärtusi hoides : haridusministeerium otsib abi eetikast / Avo Rosenvald ; kommenteerinud Tõnis Lukas, Marju Lauristin ... [jt.

    Index Scriptorium Estoniae

    2008-01-01

    26. septembril Tallinnas väärtuste ja nende arendamise teemal toimunud konverentsist "Ühiseid väärtusi hoides", mille korraldas Tartu Ülikooli eetikakeskus koostöös Haridus- ja Teadusministeeriumiga

  11. Effect of Porous Structure on the Magnetic Properties of NixMgyZn1−x−yFe2O4 Magnetic Materials

    International Nuclear Information System (INIS)

    Qi Xin; Zhou Xin; Shu Di; Zhao Jing-Jing; Wang Wei; Chen Juan

    2011-01-01

    We deal with the preparation of NiMgZnFe III -SO 4 layered double hydroxides (LDHs) with the layered precursor method and introduce excessive ZnO into the NiMgZnFe III -SO 4 LDHs to produce Ni x Mg y Zn 1−x−y Fe 2 O 4 ferrites that contain massive ZnO. Then the Ni x Mg y Zn 1−x−y Fe 2 O 4 ferrites are treated with NaOH solution to remove ZnO to produce the porous Ni x Mg y Zn 1−x−y Fe 2 O 4 magnetic material: when y = 0, porous NiZnFe 2 O 4 ferrite magnetic materials are obtained; when y ≠ 0, porous NiMgZnFe 2 O 4 ferrite magnetic materials are obtained. From analyses of these two ferrites, their pore-forming mechanism and comparison of their properties before and after they undergo the alkali treatment, we find that after being treated by the NaOH solution, NiZnFe 2 O 4 /NiMgZnFe 2 O 4 have better uniform-structure pores, which will greatly expand their pore volume, widen their application scope and improve their magnetic properties. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  12. Assessment of the Prognostic and Treatment-Predictive Performance of the Combined HOXB13:IL17BR-MGI Gene Expression Signature in the Trans-ATAC Cohort

    Science.gov (United States)

    2013-12-01

    Shak S, Tang G, et al. A multigene assay to predict recurrence of tamoxifen-treated, node-negative breast cancer. N Engl J Med 2004; 351: 2817–26. 7...Barlow WE, Shak S, et al, for The Breast Cancer Intergroup of North America. Prognostic and predictive value of the 21-gene recurrence score assay in

  13. Use of the Materials Genome Initiative (MGI approach in the design of improved-performance fiber-reinforced SiC/SiC ceramic-matrix composites (CMCs

    Directory of Open Access Journals (Sweden)

    Jennifer S. Snipes

    2016-07-01

    Full Text Available New materials are traditionally developed using costly and time-consuming trial-and-error experimental efforts. This is followed by an even lengthier material-certification process. Consequently, it takes 10 to 20 years before a newly-discovered material is commercially employed. An alternative approach to the development of new materials is the so-called materials-by-design approach within which a material is treated as a complex hierarchical system, and its design and optimization is carried out by employing computer-aided engineering analyses, predictive tools and available material databases. In the present work, the materials-by-design approach is utilized to design a grade of fiber-reinforced (FR SiC/SiC ceramic matrix composites (CMCs, the type of materials which are currently being used in stationary components, and are considered for use in rotating components, of the hot sections of gas-turbine engines. Towards that end, a number of mathematical functions and numerical models are developed which relate CMC constituents’ (fibers, fiber coating and matrix microstructure and their properties to the properties and performance of the CMC as a whole. To validate the newly-developed materials-by-design approach, comparisons are made between experimentally measured and computationally predicted selected CMC mechanical properties. Then an optimization procedure is employed to determine the chemical makeup and processing routes for the CMC constituents so that the selected mechanical properties of the CMCs are increased to a preset target level.

  14. Proefskrifbespreking Boekbespreking

    African Journals Online (AJOL)

    paradigma-verandering as die beskry- wing van wetenskapsontwikkeling oorneem en aanwend as 'n middel om teologiese teorievorming mee te be- skryf. Hoewel Engelbrecht se inter- pretasie van sowel Kuhn as Gadamer soms twyfelagtig is, wil ek nie hier daarop ingaan nie. Dit is belangriker om by Engelbrecht se eie ...

  15. Clean coal technology: gasification of South African coals - IFSA 2008

    CSIR Research Space (South Africa)

    Engelbrecht, AD

    2008-11-01

    Full Text Available stream_source_info Engelbrecht_2008.pdf.txt stream_content_type text/plain stream_size 109 Content-Encoding ISO-8859-1 stream_name Engelbrecht_2008.pdf.txt Content-Type text/plain; charset=ISO-8859-1 /var...

  16. Sibling Curves 3: Imaginary Siblings and Tracing Complex Roots

    Science.gov (United States)

    Harding, Ansie; Engelbrecht, Johann

    2009-01-01

    Visualizing complex roots of a quadratic equation has been a quest since the inception of the Argand plane in the 1800s. Many algebraic and numerical methods exist for calculating complex roots of an equation, but few visual methods exist. Following on from papers by Harding and Engelbrecht (A. Harding and J. Engelbrecht, "Sibling curves and…

  17. »Nočem biti odvisna«: Ali javne prevajalske in tolmaške storitve res negativno vplivajo na aktivno vključenost migrantov v državo gostiteljico?

    Directory of Open Access Journals (Sweden)

    Nike Kocijančič Pokorn

    2016-12-01

    Full Text Available Prispevek se sprašuje o upravičenosti določenih političnih ukrepov, ki odrekajo zagotavljanje prevajanja in tolmačenja migrantom, ter zagovarja nove pristope k jezikovni in prevodni politiki, in sicer prek raziskave, ki je bila zasnovana kot odziv na trditve, da prevajalske in tolmaške storitve ovirajo integracijo nedavnih priseljencev. Raziskava je bila izvedena na skupini prosilcev za mednarodno zaščito v azilnem domu v Ljubljani. Najprej smo zbrali podatke o jezikovnem ozadju vseh stanovalcev azilnega doma v avgustu 2014 (56 stanovalcev iz 19 različnih držav, nato pa sestavili reprezentativno skupino 18 prosilcev za mednarodno zaščito na podlagi njihovega maternega jezika in jih razdelili na dve skupini glede na čas bivanja v Sloveniji v času intervjuja (krajše ali daljše obdobje. Kvantitativne podatke o jezikovnih profilih smo zbrali z vprašalnikom, kvalitativne pa s pomočjo polstrukturiranih intervjujev, izvedenih v letu 2014, in dveh ponovitvenih intervjujev v letu 2015. Nato smo kvalitativno analizirali transkripcije vseh posnetih intervjujev, pri čemer smo se osredotočali na jezikovne in komunikacijske rešitve na različnih stopnjah migrantovega življenja v državi gostiteljici. Rezultati kažejo, da je osnovne kompromise mogoče doseči, saj so prevajalske in tolmaške storitve komplementarni koraki do neodvisnosti in kot take ne ovirajo učenja dominantnega oz. nacionalnega jezika države gostiteljice, temveč ga podpirajo.

  18. Integrating the augmented SCOR model and the ISO 15288 life cycle model into a single logistic model

    CSIR Research Space (South Africa)

    Schmitz, Peter MU

    2010-07-01

    Full Text Available using the Supply Chain Operations Reference (SCOR) model. The SANDF indicated that the augmented SCOR model (Bean, Schmitz and Engelbrecht, 2009) should be extended into a single logistics process which should include a life-cycle perspective...

  19. FULL LENGTH RESEARCH ARTICLE Osue et al. (2008) SWJ:1-4 ...

    African Journals Online (AJOL)

    Dr. Ahmed

    Current mass distribution of ivermectin to the ... antibodies, and the hazard of working with radioactive substances. .... using a modified protocol (Engelbrecht et al. .... in assumed endemic normal individuals show they have been exposed.

  20. "Um sich in vorkommenden besonderen Fällen selber rathen zu können, was rechtens (sey) ...": "Der wohl instruirte Schiffer" - ein bordpraxisnahes deutschsprachiges Handbuch des Seerechtes aus der zweiten Hälfte des 18. Jahrhunderts

    OpenAIRE

    Stettner, Heinrich

    1993-01-01

    The maritime-legal manual discussed here appeared during the second half of the eighteenth century in several editions. Those of 1769, 1771 and 1773 fail to mention the author by name although the latter contains an introduction by him. The 1792 edition, however, bears the name of Johann Andreas Engelbrecht as editor. Engelbrecht (1733-1803) lived in Bremen for many years, working first as a foreign-language correspondent and later as an assessor of averages, author of specialized Iiterature ...

  1. Magnetic soft mode behaviour investigated via multi-spin flip Raman spectroscopy on near surface Cd1-xMnxTe/Cd1-yMgyTe quantum wells

    International Nuclear Information System (INIS)

    Kehl, Christian

    2011-01-01

    The main motivation for this thesis was the experimental confirmation of the theoretically predicted magnetic soft mode and the analysis of its dependence on the hole-concentration and external B-field, as well as its disappearance with increasing sample temperature. For that purpose, CdMnTe/CdMgTe QWs (Mn: 0.6%, 1.0%) positioned close to the sample surface (13-19 nm) were investigated in an in-plane applied external magnetic field (up to 4.5 T in Voigt-geometry) via a two-colour experiment i.e. using two light sources. This allows the spin excitation of Mn-ions by simultaneously tuning the hole-concentration towards the ferromagnetic phase transition by photo-generated carriers. Thus, one tuneable laser is responsible for resonant below-barrier excitation as a probe for Multi-SF Raman scattering. The other laser excites photo-generated carriers from above barrier (2.41 eV) for tuning the hole concentration in the QW. Positioning the QW close to the sample surface causes a surface-induced p-doping of the QW (intrinsic hole concentration in the QW) and enables the active tuning of the hole concentration by photo-generated carriers due to different tunnelling behaviour of electrons and holes from the QW to the surface. The Mn-g-factor was decreased by quasi-continuously increasing the above-barrier illumination, while the below-barrier excitation was kept at a constant low power. This results in a Mn-g-factor reduction starting from its atomic value g=2.01 to lowest evaluated Mn-g-factor in this thesis g=1.77. This is a magnetic softening of 12%. Apart from the general magnetic soft mode behaviour at low temperatures, one of the main experimental results in this thesis is the confirmation of the theoretical prediction that the magnetic soft mode behaviour in the external B-field does not only depend on the carrier concentration but also on the B-field strength itself. An additional aspect is the temperature dependence of the magnetic soft mode. The Mn-g-factor decrease is suppressed with increasing temperature almost reaching the atomic Mn-g-factor at 4.2 K (g=1.99). The results of the investigations concerning the cap layer thickness impact on the QW carrier characteristics were investigated in the cap thickness range of 13 nm to 19 nm. The cap thickness configures on the one hand the intrinsic hole concentration of the QW due to the surface-induced p-doping and sets the ''starting point'' for the Mn-g-factor reduction. On the other hand the cap thickness determines the probability of electron tunnelling to the surface and thus the efficiency of the hole tuning by light. The latter is the criterion for the range of Mn-g-factor reduction by light. This two dependences were pointed out by the photo-generated hole influence on the QW PL-spectra which results in tuning the exciton-trion ratio. In summary both mechanisms are of relevance for the hole tuning and thus for the magnetic soft-mode behaviour. The mechanism of tunnelling time prevails at small cap layer thicknesses while the surface-induced p-doping plays the major role for larger cap thicknesses (>25 nm). (orig.)

  2. Excitation functions of 120Te(d,xn)121,120m,gI reactions from threshold up to 13.5 MeV: comparative studies on the production of 120gI

    International Nuclear Information System (INIS)

    Hohn, A.; Coenen, H.H.; Qaim, S.M.

    2000-01-01

    Excitation functions of the nuclear reactions 120 Te(d,xn) 121,120m,g I were measured for the first time from their respective thresholds up to 13.5 MeV. Thin samples prepared by electrolytic deposition of 99.0% enriched 120 Te on Ti-backing were used. Integral yields of 121,120m,g I were calculated from the measured cross section data. A comparison of the 122 Te(p,3n)-, 120 Te(p,n)- and 120 Te(d,2n)-processes for the production of 120g I is given. The 120 Te(d,2n)-process is unsuitable for production purposes since the yield of 120g I is very low and the level of 121 I impurity very high. The choice lies either on the 122 Te(p,3n)- or the 120 Te(p,n)-reaction and is governed by the available proton energy and the financial resources for procuring the enriched target material

  3. Multi-scale climate modelling over Southern Africa using a variable-resolution global model

    CSIR Research Space (South Africa)

    Engelbrecht, FA

    2011-12-01

    Full Text Available -mail: fengelbrecht@csir.co.za Multi-scale climate modelling over Southern Africa using a variable-resolution global model FA Engelbrecht1, 2*, WA Landman1, 3, CJ Engelbrecht4, S Landman5, MM Bopape1, B Roux6, JL McGregor7 and M Thatcher7 1 CSIR Natural... improvement. Keywords: multi-scale climate modelling, variable-resolution atmospheric model Introduction Dynamic climate models have become the primary tools for the projection of future climate change, at both the global and regional scales. Dynamic...

  4. Impacts of climate change on water resources in Southern Africa: A Review

    CSIR Research Space (South Africa)

    Kusangaya, S

    2013-10-01

    Full Text Available in their projections. Moreso, others relied on use of a single GCM (e.g. Mujere and Mazvimavi, 2012). Additionally, only a few studies used RCM (e.g. Engelbrecht (2005); Schulze et al. (2005); Tadross et al. (2005)) despite these having a better spatial resolution...

  5. OOR DIE METODE VAN ONS KERKGESKIEDSKRYWING EN OOR ...

    African Journals Online (AJOL)

    Test

    ... oor dieselfde saak bestaan albei se uitsprake in ag te neem'). Die skrywer verwyt prof. Engelbrecht dat hy hom nie hieraan gehou het nie omdat hy alleen vermeld dat die Hervormde Kerk met die koms van Jan van Riebeeck aan die. Kaap geplant is en verswyg dat „Gereformeerd" ook sy intrede hiermee. *) a.ic., bts. 6v.

  6. Cuticle scale measurement of animal fibers by SEM and AFM

    CSIR Research Space (South Africa)

    Notayi, M

    2013-12-01

    Full Text Available -1 51st Microscopy Society of Southern Africa (MSSA) Conference, Farm Inn, Pretoria, 3-6 December 2013 Cuticle scale measurement of animal fibers by SEM and AFM Notayi M, Engelbrechts JAA, Lee ME, Goosen WE, Hunter L and Botha AF Abstract...

  7. Browse Title Index

    African Journals Online (AJOL)

    Items 251 - 300 of 1006 ... Vol 47, No 6 (2005), Cricothyroidotomy in emergency practice: two case reports, Abstract PDF. D Engelbrecht ... Vol 49, No 6 (2007), Diabetes in Africa: the new pandemic. Report on the 19th World ... Vol 50, No 1 (2008), Diagnosis and Treatment of Diabetic Ketoacidosis, Abstract PDF. D G Van Zyl.

  8. Forcing of a photochemical air quality model with atmospheric fields simulated by a regional climate model

    CSIR Research Space (South Africa)

    Naidoo, M

    2010-10-01

    Full Text Available to the enhanced greenhouse effect (e.g. Engelbrecht et al, 2009). Such changes are likely to influence the future transport and chemistry of air pollutants over the region. The complexity in which climate change may affect regional air quality is evident...

  9. HTS Teologiese Studies / Theological Studies - Vol 1, No 4 (1944)

    African Journals Online (AJOL)

    Die heidelbergse kategismus as kerklike simbool · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. SP Engelbrecht, 160-173. http://dx.doi.org/10.4102/hts.v1i4.3327 ...

  10. Boekbespreking | van Aarde | HTS Teologiese Studies / Theological ...

    African Journals Online (AJOL)

    The commission meeting at Budapest 1989. (Faith and Order 1985-1989 paper 148.) De Beer, W.C.M. - Van der Walt, B.J. 1989. Reformasie op viersprong: Pasmarkeerders, loodvoetiges, hrandstigten of tigdraem? Dreyer, T.FJ. - Lerle, E. 1989. Kontakstark verkundigen: Grundzuge Bibeltreuer Predigt. Engelbrecht, E.

  11. Andries van Aarde – A sideways glance: His theological and ...

    African Journals Online (AJOL)

    Test

    2011-06-07

    Jun 7, 2011 ... The way in which the Bible has been transmitted, received and interpreted has .... For example: the Gospel of Luke and consequent Acts of ..... 1986, 'Resensensie van Engelbrecht, E., “Sending en geregtigheid in die ..... 2009, 'God, the Christ and the Spirit in William P. Young's bestseller The shack seen.

  12. The Drakensberg Escarpment as the great supplier of water to South Africa

    CSIR Research Space (South Africa)

    Taylor, SJ

    2016-11-01

    Full Text Available : Investigations of the Hydrologic Cycle in Alpine Environments: 1-41 The Drakensberg Escarpment as the great supplier of water to South Africa Taylor, SJ Ferguson, JHW Engelbrecht, Francois A Clark, VR Van Rensburg, S Barker, N ABSTRACT...

  13. South African Medical Journal - Vol 106, No 4 (2016)

    African Journals Online (AJOL)

    A multifaceted hospital-wide intervention increases hand hygiene compliance · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. B Patel, H Engelbrecht, H McDonald, V Morris, W Smythe, 335-341. http://dx.doi.org/10.7196/SAMJ.2016.v106i4.10671 ...

  14. A multifaceted hospital-wide intervention increases hand hygiene ...

    African Journals Online (AJOL)

    A multifaceted hospital-wide intervention increases hand hygiene compliance. B Patel, H Engelbrecht, H McDonald, V Morris, W Smythe. Abstract. Background. Hand hygiene is an important and basic practice that should be used by all healthcare staff to protect both themselves and their patients against infection.

  15. e .Kuraioriufn. DIE W ETENSKAPLIKE BETEKENIS VAN DIE W ERK

    African Journals Online (AJOL)

    Test

    ENGELBRECHT ver antwoordelik vir die Ou-Testamentiese vakke en Hebreeus. Die aan stelling van 'n derde professor het noodsaaklik geword, want dit sou. 85 .... De .Spreuken ran 5a/o?no omvat die nuwe vertaling en die ekse gese van die eerste 24 hoofstukke van die Spreukeboek. Die geskoold- heid in die Semitiese ...

  16. Parameter estimation using compensatory neural networks

    Indian Academy of Sciences (India)

    of interconnections among neurons but also reduces the total computing time for training. The suggested model has properties of the basic neuron ..... Engelbrecht A P, Cloete I, Geldenhuys J, Zurada J M 1995 Automatic scaling using gamma learning for feedforward neural networks. From natural to artificial computing.

  17. The effect of thermo-ammoniation on the nutritive value of maize ...

    African Journals Online (AJOL)

    nutritive value of maize residues. L.D. Snyman,* D. Aartsma, N. Barrie &. C. Engelbrecht. Department of Agricultural Development, Highveld Region,. Potchefstroom,2520. Republic of South Africa. * Authorto whom correspondenceshould be addressedat: OnderstepoortVeterinaryInstitute.Private Bag X5, Onderstepoort,.

  18. Analysis of ionic channels by a flash spectrophotometric technique applicable to thylakoid membranes : CF0, the proton channel of the chloroplast ATP synthase, and, for comparison, gramicidin

    NARCIS (Netherlands)

    Lill, H.; Althoff, Gerd; Junge, Wolfgang

    We previously introduced a flash spectrophotometric method to analyze proton conduction by CF0 in vesicles derived from thylakoid membranes (H. Lill, S. Engelbrecht, G. Schönknecht & W. Junge, 1986, Eur. J. Biochem.160:627-634). The unit conductance of CF0, as revealed by this technique, was orders

  19. Die invloed van klimaatverandering op die Suid-Afrikaanse stad en voorgestelde aanpassings

    CSIR Research Space (South Africa)

    Conradie, Dirk CU

    2017-02-01

    Full Text Available climate map, it was decided that, over and above the use of historic climatic data, climate change should also be considered. An A2 climate change scenario of the Special Report on Emission Scenarios (SRES) for the period 1961-2100 (Engelbrecht et al...

  20. Management of common animal bites in the emergency centre

    African Journals Online (AJOL)

    Professor Engelbrecht's current fields of interest are bites, stings and poisonous plants. Correspondence to: ... Cross War Memorial Children's Hospital in. Cape Town ... infections. Wound infection with Pasteurella multocida usually occurs early (within 12 ..... Dog bite prevention: an assessment of child knowledge. J Pediatr ...

  1. In situ X-ray and neutron diffraction of the Ruddlesden–Popper compounds (RE2−xSrx)0.98(Fe0.8Co0.2)1−yMgyO4−δ (RE=La, Pr): Structure and CO2 stability

    International Nuclear Information System (INIS)

    Chatzichristodoulou, C.; Hauback, B.C.; Hendriksen, P.V.

    2013-01-01

    The crystal structure of the Ruddlesden–Popper compounds (La 1.0 Sr 1.0 ) 0.98 Fe 0.8 Co 0.2 O 4−δ and (La 1.2 Sr 0.8 ) 0.98 (Fe 0.8 Co 0.2 ) 0.8 Mg 0.2 O 4−δ was investigated at 1000 °C in N 2 (a O2 =1×10 −4 ) by in-situ powder neutron diffraction. In-situ powder X-ray diffraction (PXD) was also employed to investigate the temperature dependence of the lattice parameters of the compounds in air and the oxygen activity dependence of the lattice parameters at 800 °C and 1000 °C. The thermal and chemical expansion coefficients, determined along the two crystallographic directions of the tetragonal unit cell, are highly anisotropic. The equivalent pseudo-cubic thermal and chemical expansion coefficients are in agreement with values determined by dilatometry. The chemical stability in CO 2 containing environments of various Ruddlesden–Popper compounds with chemical formula (RE 2−x Sr x ) 0.98 (Fe 0.8 Co 0.2 ) 1−y Mg y O 4−δ (RE=La, Pr), as well as their stability limit in H 2 /H 2 O=4.5 were also determined by in-situ PXD for x=0.9, 1.0 and y=0, 0.2. - Graphical abstract: Influence of electronic configuration on bond length, lattice parameters and anisotropic thermal and chemical expansion. Highlights: ► The thermal and chemical expansion coefficients are largely anisotropic. ► The expansion of the perovskite layers is constrained along the a direction. ► The studied compositions show remarkable thermodynamic stability upon reduction. ► The thermal and chemical expansion coefficients are lower than related perovskites. ► The investigated materials decompose in CO 2 containing atmospheres

  2. Using lame's petrophysical parameters for fluid detection and ...

    African Journals Online (AJOL)

    AVO synthetic gather models were created using various gas/brine/oil ... a quantitative extraction of rock properties to clearly determine lithology and fluids. ... an improved separation of high porosity sands from shale was also achieved using ...

  3. Sügiskonverents "Kunst paguluses"...

    Index Scriptorium Estoniae

    2008-01-01

    28. VIII Kumu Kunstimuuseumi auditooriumis toimuva konverentsi kava. Esinevad Jaan Undusk, Piret Kruuspere, Avo Hirvesoo, Mara Lace, Osvaldas Daugelis, Piret Noorhani, Irja Bergström, Tiiu Talvistu ja Kersti Koll

  4. Elektrooniline raamat iga padja alla / Aavo Kokk

    Index Scriptorium Estoniae

    Kokk, Aavo, 1964-

    2010-01-01

    Autor arutleb, kuidas muudavad uued tehnilised lahendused raamatute lugemise harjumusi ning raamatuturgu. Elektroonilisest raamatust Sony Reader. Avo Kokk juhatab Balti raamatumessi raames toimuvat konverentsi "E-raamat: evolutsioon või revolutsioon"

  5. Individual reports : Finland : 1992-1998

    Index Scriptorium Estoniae

    1999-01-01

    EMKÜ presidendi Avo Kartuli külaskäigust Soome raamatukogudesse 1992. aastal ja Eesti Rahvusraamatukogu Kunstide Teabekeskuse töötajate Aurika Gergelezhiu ja Linda Tõnissoni külaskäigust vastavalt 1993. ja 1998. aastal

  6. Common-image gathers in the offset domain from reverse-time migration

    KAUST Repository

    Zhan, Ge; Zhang, Minyu

    2014-01-01

    Kirchhoff migration is flexible to output common-image gathers (CIGs) in the offset domain by imaging data with different offsets separately. These CIGs supply important information for velocity model updates and amplitude-variation-with-offset (AVO

  7. Korruptsioonikonverents valitsuse ja kolmanda sektori koostöö heaks / Rait Kaarma, Kersti Kurre

    Index Scriptorium Estoniae

    Kaarma, Rait

    2004-01-01

    Eesti Maksumaksjate Liidu korraldatud rahvusvahelisest konverentsist "Korruptsioonivastane võitlus Eestis". Väljavõtted Avo Üpruse, Pille Kustovi, Bogdan Senschuki, Anne Schmidti ja Norman Aasa sõnavõttudest

  8. A packed Estonian House welcomes back Estonian President Toomas Hendrik Ilves / Adu Raudkivi

    Index Scriptorium Estoniae

    Raudkivi, Adu

    2008-01-01

    President Toomas Hendrik Ilvese külaskäigust Toronto Eesti Majja 27. mail 2008. Juuresoleval fotol Eesti riigipea koos Ülemaailmse Eesti Kesknõukogu esimehe Avo Kittaski ja Eesti Ohvitseridekogu Kanadas esimehe Ülo Isbergiga

  9. 28. jaanuarini olid...

    Index Scriptorium Estoniae

    2001-01-01

    Eesti graafikute Avo Keerendi ja Benjamin Vassermani tööd olid Poola rahvusvahelisel graafikanäitusel "Graphic Constellation - Szczecin 2000" alapealkirjaga "Seeking the New Space". A. Keerendi tööd on reprodutseeritud kataloogis.

  10. Full Waveform Inversion for Reservoir Characterization - A Synthetic Study

    KAUST Repository

    Zabihi Naeini, E.; Kamath, N.; Tsvankin, I.; Alkhalifah, Tariq Ali

    2017-01-01

    Most current reservoir-characterization workflows are based on classic amplitude-variation-with-offset (AVO) inversion techniques. Although these methods have generally served us well over the years, here we examine full-waveform inversion (FWI

  11. Mis saab Tallinna Polütehnikumist? / Sirje Tohver ; kommenteerib Mati Kask

    Index Scriptorium Estoniae

    Tohver, Sirje, 1948-

    2000-01-01

    Tallinna Polütehnikumi liitmisest Tallinna Kõrgema Tehnikakõrgkooliga. Arvamust avaldavad TPT õppealadirektor Jüri Mickfeldt ja AS Eesti Telefon IP Teenused turundusjuht Avo-Rein Tereping (TPT vilistlane, kooli nõukogu liige)

  12. Development of a moisture scheme for the explicit numerical simulation of moist convection

    CSIR Research Space (South Africa)

    Bopape, Mary-Jane M

    2010-09-01

    Full Text Available .kashan.co.za] Development of a moisture scheme for the explicit numerical simulation of moist convection M BOPAPE, F ENGELBRECHT, D RANDALL AND W LANDMAN CSIR Natural Resources and the Environment, PO Box 395, Pretoria, 0001, South Africa Email: mbopape... sigma coordinate model that incorporates moisture effects, so that it can simulate convective clouds and precipitation. moisture terms equivalent to those of the miller and pearce (1974) model are incorporated in the equation set used: ; (1) ; (2...

  13. Kerkgeskiedenis in ons teologiese opleiding: 1917-1956

    Directory of Open Access Journals (Sweden)

    A. D. Pont

    1992-01-01

    Full Text Available Church history in our theological training: 1917-1956 After a short summary of the history of the founding of the Theological Faculty at the old Transvaal University College, attention is given to the Department of Church History. During the years 1921-1956 professor S P Engelbrecht built up this Department. Attention is given to his work as Church historian, his theological position is discussed and the result of his labours is given.

  14. Determining the Value of Future Information

    Science.gov (United States)

    2011-03-01

    trouble spots around the world, help plan military operations, and monitor the environment. The NRO’s Operational Support Office ( OSO ) “orchestrates...offices” (Parnell, Bennet, Engelbrecht, Szafranski, 2002:77). Parnell’s team’s research was intended “to help the OSO to identify and develop high- value...tasks that directly support OSO and NRO strategic objectives and to select the best portfolio of tasks to meet resource and programmatic constraints

  15. Characterizing and Quantifying Emissions and Transport of Fugitive Dust Emissions Due to Department of Defense Activities

    Science.gov (United States)

    2015-09-19

    response to shear stress (τ, N m-2) induced by the PI-SWERL®, the viscosity of the fluid exerts a torque (N m-1) that eventually balances with τ. The...Engelbrecht et al. (2012) from CCSEM measurements, report that these silicate mineral particles are largely coated by a veneer of clay minerals and fine...content does not, by itself, contribute to the high emissions observed at YTC. The presence of high clay content can constrain the emissions by

  16. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  17. Comparative trial of Aloe vera/olive oil combination cream versus phenytoin cream in the treatment of chronic wounds.

    Science.gov (United States)

    Panahi, Y; Izadi, M; Sayyadi, N; Rezaee, R; Jonaidi-Jafari, N; Beiraghdar, F; Zamani, A; Sahebkar, A

    2015-10-01

    Aloe vera is a medicinal plant that has been traditionally used to accelerate wound healing. Olive oil is also a natural product that may contribute to wound healing owing to its antimicrobial and anti-inflammatory effects. The present study aimed to evaluate the effect of an Aloe vera-olive oil (AVO) combination cream on the healing process of chronic wounds. In this randomised, double-blind, comparator-controlled, parallel-group trial, patients with chronic wounds were treated with either AVO cream or phenytoin cream as the standard treatment for a period of 30 days. Wound healing was evaluated using Bates-Jensen assessment tool and the severity of pain was assessed using a visual analogue scale (VAS). After initial assessment, 60 patients with chronic wounds (41 with pressure ulcer, 13 with diabetic wounds and 6 with venous ulcers), were recruited and randomised into 2 groups of 30. After 30 days of treatment, significant improvements in the wound size, depth, and edges; necrotic tissue type and amount; exudate type and amount; colour of wound surroundings; and peripheral tissue oedema score were observed in the AVO cream group (p<0.001). The total score of wound healing showed significant improvement with both AVO (p<0.001) and phenytoin (p<0.01) creams, although AVO was more efficacious (p<0.001). Likewise, although both treatments reduced the initial VAS score, the efficacy of AVO was significantly greater (p<0.001). AVO cream significantly accelerates biological healing of chronic wounds and helps to reduce pain severity with a higher efficacy compared with phenytoin cream.

  18. 2013 MDEQ-FEMA Rankin-Simpson Co. Lidar Survey

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fugro as a subconsultant to MGI was authorized to undertake this project, as a part of Work Order No. 112, dated November 1, 2012, issued to MGI in accordance with...

  19. Adult exposures from MDCT including multiphase studies: first Italian nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Palorini, Federica; Origgi, Daniela [Fisica Sanitaria Istituto Europeo di Oncologia, Milan (Italy); Granata, Claudio [UOC di Radiologia Istituto Giannina Gaslini, Genoa (Italy); Matranga, Domenica [Universita degli Studi di Palermo, Dipartimento di Scienze per la Promozione della Salute e Materno-infantile ' ' G. D' Alessandro' ' , Palermo (Italy); Salerno, Sergio [Policlinico Universita di Palermo, Dipartimento di Scienze Radiologiche, Palermo (Italy)

    2014-02-15

    To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population. This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest-abdomen-pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDI{sub vol}) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure. The 75th percentiles of CTDI{sub vol} (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm, respectively; for chest, 15 mGy and 569 mGy cm; spine, 42 mGy and 888 mGy cm; cardiac, 7 mGy and 131 mGy cm for calcium score, and 61 mGy and 1,208 mGy cm for angiographic CT studies. High variability was present in the DLP of abdomen and CAP protocols, where multiphase examinations dominated (71 % and 73 % respectively): for abdomen, 18 mGy, with 555 and 920 mGy cm in abdomen and abdomen-pelvis acquisitions respectively; for CAP, 17 mGy, with 508, 850 and 1,200 mGy cm in abdomen, abdomen-pelvis and CAP acquisitions respectively. The results of this survey could help in the definition of updated diagnostic reference levels (DRL). (orig.)

  20. Development and Examination of Sweet Potato Flour Fortified with Indigenous Underutilized Seasonal Vegetables

    Directory of Open Access Journals (Sweden)

    Ernest Teye

    2018-01-01

    Full Text Available Developing nutrient-rich vegetable flour using locally under-utilized food crops in Africa would improve rural house-hold nutrition. This study seeks to develop nutrient-dense vegetable flour from different proportions of Sweet potato (Sp 40–100%, Avocado pear (Avo 10–40%, and Turkey berry (Tor 10–40%, using completely randomized design (CRD with 14 treatment combinations and three replications. The proximate composition, mineral composition, and functional properties were investigated on the composite flour. The results showed significant differences in all the parameters analyzed for the various composite flours. As the amount of Avo and Tor was added to the Sp, the proximate composition was enhanced except for the percentage carbohydrate, which decreased from 83.92 to 54.59 g/100 g. The mineral composition was also improved by the incorporation of Avo and Tor. Favourable functional properties were also obtained. The optimal composite flour was made up of 40% Sp, 35% Avo, and 25% Tor. The functional properties of the composite flours were better than the control (Sweet potato flour. Fortifying Sp flour with Avo and Tor is feasible and could be an easy and affordable means to improve rural nutrition, as it requires simple logistics for the ordinary rural household to produce the composite of the desired choice.

  1. Negligible heat strain in armored vehicle officers wearing personal body armor

    Directory of Open Access Journals (Sweden)

    Hunt Andrew P

    2011-07-01

    Full Text Available Abstract Objectives This study evaluated the heat strain experienced by armored vehicle officers (AVOs wearing personal body armor (PBA in a sub-tropical climate. Methods Twelve male AVOs, aged 35-58 years, undertook an eight hour shift while wearing PBA. Heart rate and core temperature were monitored continuously. Urine specific gravity (USG was measured before and after, and with any urination during the shift. Results Heart rate indicated an intermittent and low-intensity nature of the work. USG revealed six AVOs were dehydrated from pre through post shift, and two others became dehydrated. Core temperature averaged 37.4 ± 0.3°C, with maximum's of 37.7 ± 0.2°C. Conclusions Despite increased age, body mass, and poor hydration practices, and Wet-Bulb Globe Temperatures in excess of 30°C; the intermittent nature and low intensity of the work prevented excessive heat strain from developing.

  2. A survey of patients dose management in computed tomography with special emphasis to paetriatric patients in Ghana

    International Nuclear Information System (INIS)

    Inkoon, S.; Emi-Reynolds, G.; Boadu, M.; Schandorf, C.

    2010-01-01

    A survey of the frequency of common computed tomography (CT) examinations and the doses of six (6) CT facilities in Ghana has been undertaken. The technique factors for both adult and paediatric examinations were assessed. The dosimetric parameter used was the weighted computerized tomography dose index (CTDIw) for a single slice and the dose length product (DLP) for complete CT examinations of chest, chest high resolution (HR), lumbar spine, abdomen and pelvis. The effective dose (E) was estimated to give the stochastic radiation risk of a non-uniform exposure in terms of a whole body exposure. It was observed that some facilities used the same adult CT technique factors for paediatric patients. Mean values of adult CTDIw ranged as: chest (7.1-29.7 mGy), chest HR (7.1-30.0 mGy), lumbar spine (13.4-42.4 mGy), abdomen (7.8-42.4 mGy) and pelvis (8.9-42.4 mGy). Mean paediatric CTDIw values ranged as: chest (6.4-29.7 mGy), chest HR (6.4-30.0 mGy), lumbar spine (10.1-42.4 mGy), abdomen (10.1-42.4 mGy) and pelvis (10.1-42.4 mGy). The mean adult DLP values ranged as: chest (178-594 mGy cm), chest HR (168-594 mGy cm), lumbar spine (287-848 mGy cm), abdomen (233-848 mGy cm) and pelvis (228-848 mGy cm). However the mean paediatric DLP values ranged as: chest (128-594 mGy cm), chest HR (113-594 mGy cm), lumbar spine (253-848 mGy cm), abdomen (146-848 mGy cm) and pelvis (202-848 mGy cm). The E values for adults ranged as follows: chest (3.0-10.1 mSv), chest HR (2.9-10.1 mSv), lumbar spine (4.3-12.7 mSv), abdomen (3.5-12.7 mSv) and pelvis (4.3-12.7 mSv). The results show some agreement with diagnostic reference levels of CTDIw DLP and E values from literature. Nevertheless, further optimisation studies are needed to further reduce patient doses and modifications of technique factors especially for paediatrics (author)

  3. Amplitude versus offset analysis to marine seismic data acquired in Nankai Trough, offshore Japan where methane hydrate exists

    Science.gov (United States)

    Hato, M.; Inamori, T.; Matsuoka, T.; Shimizu, S.

    2003-04-01

    Occurrence of methane hydrates in the Nankai Trough, located off the south-eastern coast of Japan, was confirmed by the exploratory test well drilling conducted by Japan’s Ministry of International Trade and Industry in 1999. Confirmation of methane hydrate has given so big impact to the Japan's future energy strategy and scientific and technological interest was derived from the information of the coring and logging results at the well. Following the above results, Japan National Oil Corporation (JNOC) launched the national project, named as MH21, for establishing the technology of methane hydrate exploration and related technologies such as production and development. As one of the research project for evaluating the total amount of the methane hydrate, Amplitude versus Offset (AVO) was applied to the seismic data acquired in the Nankai Trough area. The main purpose of the AVO application is to evaluate the validity of delineation of methane hydrate-bearing zones. Since methane hydrate is thought to accompany with free-gas in general just below the methane hydrate-bearing zones, the AVO has a possibility of describing the presence of free-gas. The free-gas is thought to be located just below the base of methane hydrate stability zone which is characterized by the Bottom Simulating Reflectors (BSRs) on the seismic section. In this sense, AVO technology, which was developed as gas delineation tools, can be utilized for methane hydrate exploration. The result of AVO analysis clearly shows gas-related anomaly below the BSRs. Appearance of the AVO anomaly has so wide variety. Some of the anomalies might not correspond to the free-gas existence, however, some of them may show free-gas. We are now going to develop methodology to clearly discriminate free-gas from non-gas zone by integrating various types of seismic methods such as seismic inversion and seismic attribute analysis.

  4. 2014 volcanic activity in Alaska: Summary of events and response of the Alaska Volcano Observatory

    Science.gov (United States)

    Cameron, Cheryl E.; Dixon, James P.; Neal, Christina A.; Waythomas, Christopher F.; Schaefer, Janet R.; McGimsey, Robert G.

    2017-09-07

    The Alaska Volcano Observatory (AVO) responded to eruptions, possible eruptions, volcanic unrest or suspected unrest, and seismic events at 18 volcanic centers in Alaska during 2014. The most notable volcanic activity consisted of intermittent ash eruptions from long-active Cleveland and Shishaldin Volcanoes in the Aleutian Islands, and two eruptive episodes at Pavlof Volcano on the Alaska Peninsula. Semisopochnoi and Akutan volcanoes had seismic swarms, both likely the result of magmatic intrusion. The AVO also installed seismometers and infrasound instruments at Mount Cleveland during 2014.

  5. 2015 Volcanic activity in Alaska—Summary of events and response of the Alaska Volcano Observatory

    Science.gov (United States)

    Dixon, James P.; Cameron, Cheryl E.; Iezzi, Alexandra M.; Wallace, Kristi

    2017-09-28

    The Alaska Volcano Observatory (AVO) responded to eruptions, volcanic unrest or suspected unrest, and seismic events at 14 volcanic centers in Alaska during 2015. The most notable volcanic activity consisted of continuing intermittent ash eruptions from Cleveland and Shishaldin volcanoes in the Aleutian Islands. Two eruptive episodes, at Veniaminof and Pavlof, on the Alaska Peninsula ended in 2015. During 2015, AVO re-established the seismograph network at Aniakchak, installed six new broadband seismometers throughout the Aleutian Islands, and added a Multiple component Gas Analyzer System (MultiGAS) station on Augustine.

  6. A short-range ensemble prediction system for southern Africa

    CSIR Research Space (South Africa)

    Park, R

    2012-10-01

    Full Text Available system for southern Africa R PARK, WA LANDMAN AND F ENGELBRECHT CSIR, PO Box 395, Pretoria, South Africa, 0001 Email: xxxxxxxxxxxxxx@csir.co.za ? www.csir.co.za INTRODUCTION This research has been conducted in order to develop a short-range ensemble... stream_source_info Park_2012.pdf.txt stream_content_type text/plain stream_size 7211 Content-Encoding ISO-8859-1 stream_name Park_2012.pdf.txt Content-Type text/plain; charset=ISO-8859-1 A short-range ensemble prediction...

  7. The management of scarce water resources using GNSS, InSAR and in-situ micro gravity measurements as monitoring tools

    CSIR Research Space (South Africa)

    Wonnacott, R

    2015-08-01

    Full Text Available of Geomatics, Vol. 4, No. 3, August 2015 213  The management of scarce water resources using GNSS, InSAR and in-situ micro gravity measurements as monitoring tools Richard Wonnacott1, Chris Hartnady1, Jeanine Engelbrecht2 1Umvoto Africa (Pty) Ltd... shown to provide a useful tool for the measurement and monitoring of ground subsidence resulting from numerous natural and anthropogenic causes including the abstraction of groundwater and gas. Zerbini et al (2007) processed and combined data from a...

  8. Dynamic multi-objective optimisation using PSO

    CSIR Research Space (South Africa)

    Greeff, M

    2010-01-01

    Full Text Available there is a significant difference in the performance of one algorithm compared to another algorithm, statistical tests are used as explained in Section 4.3. 4.3 Statistical Analysis To determine whether there is a difference in performance with respect... This section discusses the results that were obtained from the experiments, with regards to the performance of the variations of VEPSO and the effect of 10 Marde´ Greeff and Andries P. Engelbrecht Table 1. p-values of Statistical Tests Function Kruskal...

  9. New technology for the independent producer

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-01

    This technology transfer conference consisted of the following six sessions: reservoir characterization; drilling, testing and completion; enhanced oil recovery; 3-d seismic and amplitude variation with offset (AVO); biotechnology for field applications; and well logging technology. Selected papers have been processed separately for inclusion in the Energy Science and Technology Database.

  10. Eesti graafika rahvusvahelisel areenil / Benjamin Vasserman

    Index Scriptorium Estoniae

    Vasserman, Benjamin

    1999-01-01

    26. VIII-28. XI Fredrikstadis Hebleri-nim. rahvusvahelises graafikakeskuses avatud XII Norra rahvusvahelisel graafikatriennaalil esindavad Eestit Anu Kalm, Avo Keerend, Vive Tolli, Benjamin Vasserman, Mare Vint. Peapreemia ئ Anthony Hill. Triennaali president - Herman Hebler (s. 1911). 24. VI-15. IX Poolas toimunud X Lodzi rahvusvahelisel väikegraafika triennaalil osalesid Eestist Virge Jõekalda, Benjamin Vasserman.

  11. The economics of potential reduction of the rural road system in Kansas.

    Science.gov (United States)

    2011-11-01

    Benefitcost analysis was used to examine the question of road closure in the three counties. The cost of road : closure is the additional travel cost of rural residents due to more circuitous routing to their destinations. The benefit is : the avo...

  12. Catalog of earthquake hypocenters at Redoubt Volcano and Mt. Spurr, Alaska: October 12, 1989 - December 31, 1990

    Science.gov (United States)

    Power, John A.; March, Gail D.; Lahr, John C.; Jolly, Arthur D.; Cruse, Gina R.

    1993-01-01

    The Alaska Volcano Observatory (AVO), a cooperative program of the U.S. Geological Survey, the Geophysical Institute of the University of Alaska, Fairbanks, and the Alaska Division of Geological and Geophysical Surveys, began a program of seismic monitoring at potentially active volcanoes in the Cook Inlet region in 1988. Seismic monitoring of this area was previously accomplished by two independent seismic networks operated by the U.S. Geological Survey (Northern Cook Inlet) and the Geophysical Institute (Southern Cook Inlet). In 1989 the AVO seismic program consisted of three small-aperture networks of six, five, and six stations on Mt. Spurr, Redoubt Volcano, and Augustine Volcano respectively. Thirty-five other stations were operated in the Cook Inlet region as part of the AVO program. During 1990 six additional stations were added to the Redoubt network in response to eruptive activity, and three stations were installed at Iliamna Volcano. The principal objectives of the AVO program have been the seismic surveillance of the Cook Inlet volcanoes and the investigation of seismic processes associated with active volcanism.

  13. Omavalitsusjuhid Riigikontrolli urgitsemist ei karda / Erik Kalda

    Index Scriptorium Estoniae

    Kalda, Erik, 1969-

    2005-01-01

    Ilmunud ka: Severnoje 18. märts lk. 1,4. Poberezhje Iisaku vallavanem Avo Kiir, Kohtla-Järve linnapea Jevgeni Solovjov, Narva linnavolikogu esimees Mihhail Stalnuhhin, Jõhvi linnapea Aavo Keerme, Ida-Viru omavalitsuste liidu tegevdirektor Urve Erikson ja Sillamäe volikogu esimees Valdek Murd kommenteerivad valitsuses heakskiidu leidnud Riigikontrolli volituste laiendamist

  14. Journal of Biosciences | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    In this study, we reveal that the eisosome organizer Pil1 colocalizes with the MCT marker Avo2. Furthermore, we provide evidence that the formation of MCT is dependent on both eisosome integrity and adequate levels of the plasma membrane phosphoinositide PI(4,5)P2. Taken together, our findings indicate that TORC2, ...

  15. Largo mahlatööstus kolib pealinnast Võhmasse / Hans Väre

    Index Scriptorium Estoniae

    Väre, Hans, 1979-

    2007-01-01

    Jõustus Svensky Kaubanduse ja Largo endise omaniku, piimatööstuse Tere vaheline müügileping, mille järgi saab Svenksy Kaubandus endale kõik Largoga seonduva alates kaubamärgist ja seadmetest, lõpetades toodanguga. Arvamust avaldab Võhma linnapea Avo Põder

  16. Petroleum resources assessment (II)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    This report consists of 4 subjects. 1) An interactive seismic velocity analysis, 2) AVO analysis for direct hydrocarbon detection, 3) 3D seismic data processing, 4) Study of structural(syncline) effect of the near surface on the resolution of anticline oil trap structure by seismic modeling. (author). 36 refs., 3 tabs., 97 figs.

  17. Georgi söögituba Kotli majas / Helju Koger

    Index Scriptorium Estoniae

    Koger, Helju, 1943-

    2006-01-01

    Georg Lurichi järgi nime saanud söögitoast arhitekt Alar Kotli vanaisale kuulunud hoones Väike-Maarjas. Enne renoveerimist koliti hoone teise kohta. Söögitoa kujunduse tegi Kai Tort, mööbli valmistasid kohalikud puusepad, plekist lambid - Ilmar Aasumets. Omanik Avo Part. 7 värv. ill

  18. Georgi söögituba Väike-Maarjas / Kai Tort, Ilmar Aasumets

    Index Scriptorium Estoniae

    Tort, Kai

    2006-01-01

    7 ill.; Georg Lurichi järgi nime saanud söögituba asub arhitekt Alar Kotli vanaisale kuulunud hoones; söögitoa kujunduse tegi Kai Tort, mööbli valmistasid kohalikud puusepad, plekist lambid - Ilmar Aasumets, omanik Avo Part

  19. Nokia ja Sirmens panevad leivad ühte kappi / Lauri Matsulevitsh

    Index Scriptorium Estoniae

    Matsulevitsh, Lauri

    2006-01-01

    Nokia ja Siemens ühendavad võrguseadmete tootmise. Lisa: Annika Matson. Eesti võib võita uusi töökohti. Küsimustele vastab Avo Tihamäe. Diagramm: Ühinemisuudis pani aktsiad liikuma. Vt. samas: Sirje Rank. Analüütikud: Siemens võidab tehingust enam; Võrguseadmete tootjatel peal liitumistuhin

  20. Fiber Optic Chemical Sensors

    Science.gov (United States)

    1993-10-01

    31, 1980. Koyama, Masao and Sato , Yuichi, "Improved Enzyme Sensor for Glucose with an Ultra-Filtration Membrane and Immobilized Glucose Oxidase...ion Process," American Laboratory, AVO, AIS, 54-59, 1989. Kaihara, Mikio ; Mametsuka, Hiroaki; Gunji, Naoki; Iwata, Hideo and Gohshi,, "New Dilution

  1. 30. IX kuni 31. XII 2000 toimus Makedoonia Vabariigis...

    Index Scriptorium Estoniae

    2001-01-01

    III rahvusvaheline graafikatriennaal "Bitola 2000" teemadel "2000 aastat kristlust" ja "Metamorfoos". Eestist osalesid Peeter Allik, Sirje Eelma, Kelli Kagovere, Avo Keerend, Ilmar Kruusamäe, Raul Meel, Benjamin Vasserman. Peapreemia - poola graafiku Mira Boczniowiczi töö "Empire Sign".

  2. Journal of Earth System Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Earth System Science; Volume 126; Issue 3 ... Decomposition of wind speed fluctuations at different time scales .... Bayesian inversion of synthetic AVO data to assess fluid and shale content in sand-shale media ... Geochemical characteristics of sandstones from Cretaceous Garudamangalam ...

  3. Eesti graafika Rio de Janeiros / Jüri Kass

    Index Scriptorium Estoniae

    Kass, Jüri

    1999-01-01

    15. sept.-st Krakovi graafikatriennaali valiknäitusel Rio de Janeiro kaasaegse kunsti muuseumis esinevad Eestist Peeter Allik, Inga Heamägi, Eve Kask, Avo Keerend, Malle Leis, Ülle Marks, Raul Meel. 1997. a. Krakovi triennaalil ning sellele järgnenud sateliit- ja jätkunäitustel Eestist osalenud kunstnike loetelu.

  4. Tallinna Kool - silla ehitajad Eesti aega, aga ka lääne nüüdisaegsesse arhitektuuri / Leonhard Lapin

    Index Scriptorium Estoniae

    Lapin, Leonhard, 1947-

    2008-01-01

    Eesti arhitektide rühmitusest Tallinna Kool. Tegutses 1972-1985. Esimese manifesti koostajad on Tiit Kaljundi, Vilen Künnapu, Leonhard Lapin, Avo-Him Looveer ja Ülev Eljand. Oluline oli Tallinna Kooli arhitektide grupinäitus 1978. a. Näitus "Keskkonnad, projektid, kontseptsioonid. Tallinna Kooli arhitektid 1972-1985" Rotermanni soolalaos

  5. Use of new and old technologies and methods by the Alaska Volcano Observatory during the 2006 eruption of Augustine Volcano, Alaska

    Science.gov (United States)

    Murray, T. L.; Nye, C. J.; Eichelberger, J. C.

    2006-12-01

    The recent eruption of Augustine Volcano was the first significant volcanic event in Cook Inlet, Alaska since 1992. In contrast to eruptions at remote Alaskan volcanoes that mainly affect aviation, ash from previous eruptions of Augustine has affected communities surrounding Cook Inlet, home to over half of Alaska's population. The 2006 eruption validated much of AVO's advance preparation, underscored the need to quickly react when a problem or opportunity developed, and once again demonstrated that while technology provides us with wonderful tools, professional relationships, especially during times of crisis, are still important. Long-term multi-parametric instrumental monitoring and background geological and geophysical studies represent the most fundamental aspect of preparing for any eruption. Once significant unrest was detected, AVO augmented the existing real-time network with additional instrumentation including web cameras. GPS and broadband seismometers that recorded data on site were also quickly installed as their data would be crucial for post-eruption research. Prior to 2006, most of most of AVO's eruption response plans and protocols had focused on the threat to aviation rather than ground-based hazards. However, the relationships and protocols developed for the aviation threat were sufficient to be adapted to the ash fall hazard, though it is apparent that more work, both scientific and with response procedures, is needed. Similarly, protocols were quickly developed for warning of a flank- collapse induced tsunami. Information flow within the observatory was greatly facilitated by an internal web site that had been developed and refined specifically for eruption response. Because AVO is a partnership of 3 agencies (U.S. Geological Survey, University of Alaska Fairbanks Geophysical Institute, and the Alaska Division of Geological and Geophysical Surveys) with offices in both Fairbanks and Anchorage, web and internet-facing data servers provided

  6. Patient dosimetry in hysterosalpingography

    International Nuclear Information System (INIS)

    Khoury, H.J.; Maia, A.; Oliveira, M.; Kramer, R.; Drexler, G.

    2001-01-01

    The objectives of this study were to determine the entrance surface dose to the patient and to estimate the dose to the uterus and ovaries due to hysterosalpingography (HSG) diagnostic examinations performed in Recife-Pe, Brazil. The entrance doses were measured using four thermoluminescent dosimeters per patient, attached to anatomical landmarks on the patient's skin. The study was carried out on 25 patients between 21 and 45 years of age who underwent the HSG examinations in two training hospitals and one private radiodiagnostic institute. The number of exposures performed ranged from 4 to 15 radiographs per patient measured. Entrance surface doses varied between 4.99 and 36.6 mGy, with an average of 12.6mGy. The doses to the ovaries and uterus ranged from 0.80 mGy to 5.8 mGy and 1.10mGy to 8.05 mGy, respectively. (author)

  7. Optimizing the balance between radiation dose and image quality in pediatric head CT: findings before and after intensive radiologic staff training.

    Science.gov (United States)

    Paolicchi, Fabio; Faggioni, Lorenzo; Bastiani, Luca; Molinaro, Sabrina; Puglioli, Michele; Caramella, Davide; Bartolozzi, Carlo

    2014-06-01

    The purpose of this study was to assess the radiation dose and image quality of pediatric head CT examinations before and after radiologic staff training. Outpatients 1 month to 14 years old underwent 215 unenhanced head CT examinations before and after intensive training of staff radiologists and technologists in optimization of CT technique. Patients were divided into three age groups (0-4, 5-9, and 10-14 years), and CT dose index, dose-length product, tube voltage, and tube current-rotation time product values before and after training were retrieved from the hospital PACS. Gray matter conspicuity and contrast-to-noise ratio before and after training were calculated, and subjective image quality in terms of artifacts, gray-white matter differentiation, noise, visualization of posterior fossa structures, and need for repeat CT examination was visually evaluated by three neuroradiologists. The median CT dose index and dose-length product values were significantly lower after than before training in all age groups (27 mGy and 338 mGy ∙ cm vs 107 mGy and 1444 mGy ∙ cm in the 0- to 4-year-old group, 41 mGy and 483 mGy ∙ cm vs 68 mGy and 976 mGy ∙ cm in the 5- to 9-year-old group, and 51 mGy and 679 mGy ∙ cm vs 107 mGy and 1480 mGy ∙ cm in the 10- to 14-year-old group; p training were significantly lower than the levels before training (p staff training can be effective in reducing radiation dose while preserving diagnostic image quality in pediatric head CT examinations.

  8. Estimation of radiation dose for adult and pediatric patients during X-ray examinations in Khartoum State

    International Nuclear Information System (INIS)

    Altahir, Ataalmanan Yosif Ataalmanan

    2018-01-01

    The aim of this study to evaluate the patient doses in X-ray examinations for skull and in three main hospitals in Khartoum State. The examination parameters took from 125 radiographs for both male and female were the females was 58 and the male 67 patients undergoing skull (AP), were the age of pediatric patients 1-18 years and adults 19-79 years. The result shows that the calculation of ESAK for according to gender for male skull 0.206 mGy, and ESAK according to gender for male skull 0.0719 mGy, for female skull 0.0942 mGy, for male chest 0.082 mGy and female for female chest 0.098 mGy. The calculation of ESAK according to patients age, adults and pediatric, the ESAK estimation for adults 0.122 mGy for skull, 0.1306 mGy for chest, and for pediatric 0.0432 mGy for skull, 0.055 mGy for chest. This data will be useful for the formulation of national reference levels as recommended by the International Atomic Energy Agency (IAEA). (Author)

  9. Radiation absorbed doses in cephalography

    International Nuclear Information System (INIS)

    Eliasson, S.; Julin, P.; Richter, S.; Stenstroem, B.

    1984-01-01

    Radiation absorbed doses to different organs in the head and neck region in lateral (LAT) and postero-anterior (PA) cephalography were investigated. The doses were measured by thermoluminescence dosimeters (TLD) on a tissue equivalent phantom head. Lanthanide screens in speed group 4 were used at 90 and 85 k Vp. A near-focus aluminium dodger was used and the radiation beam was collimated strictly to the face. The maximum entrance dose from LAT was 0.25 mGy and 0.42 mGy from a PA exposure. The doses to the salivary glands ranged between 0.2 and 0.02 mGy at LAT and between 0.15 and 0.04 mGy at PA exposures. The average thyroid gland dose without any shielding was 0.11 mGy (LAT) and 0.06 mGy (PA). When a dodger was used the dose was reduced to 0.07 mGy (LAT). If the thyroid gland was sheilded off, the dose was further reduced to 0.01 mGy and if the thyroid region was collimated out of the primary radiation field the dose was reduced to only 0.005 mGy. (authors)

  10. Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography

    International Nuclear Information System (INIS)

    Kirchhoff, S.; Herzog, P.; Johnson, T.; Boehm, H.; Nikolaou, K.; Reiser, M.F.; Becker, C.H.

    2010-01-01

    Objective: The radiation exposure of a dual-source-64-channel multi-detector-computed-tomography-scanner (Somatom-Defintion, Siemens, Germany) was assessed in a phantom-study performing coronary-CT-angiography (CTCA) in comparison to patients' data randomly selected from routine scanning. Methods: 240 CT-acquisitions of a computed tomography dose index (CTDI)-phantom (PTW, Freiburg, Germany) were performed using a synthetically generated Electrocardiography (ECG)-signal with variable heart rates (30-180 beats per minute (bpm)). 120 measurements were acquired using continuous tube-output; 120 measurements were performed using ECG-synchronized tube-modulation. The pulsing window was set at minimum duration at 65% of the cardiac cycle between 30 and 75 bpm. From 90-180 bpm the pulsing window was set at 30-70% of the cardiac cycle. Automated pitch adaptation was always used. A comparison between phantom CTDI and two patient groups' CTDI corresponding to the two pulsing groups was performed. Results: Without ECG-tube-modulation CDTI-values were affected by heart-rate-changes resulting in 85.7 mGray (mGy) at 30 and 45 bpm, 65.5 mGy/60 bpm, 54.7 mGy/75 bpm, 46.5 mGy/90 bpm, 34.2 mGy/120 bpm, 27.0 mGy/150 bpm and 22.1 mGy/180 bpm equal to effective doses between 14.5 mSievert (mSv) at 30/45 bpm and 3.6 mSv at 180 bpm. Using ECG-tube-modulation these CTDI-values resulted: 32.6 mGy/30 bpm, 36.6 mGy/45 bpm, 31.4 mGy/60 bpm, 26.8 mGy/75 bpm, 23.7 mGy/90 bpm, 19.4 mGy/120 bpm, 17.2 mGy/150 bpm and 15.6 mGy/180 bpm equal to effective doses between 5.5 mSv at 30 bpm and 2.6 mSv at 180 bpm. Significant CTDI-differences were found between patients with lower/moderate and higher heart rates in comparison to the phantom CTDI-results. Conclusions: Dual source CTCA is particularly dose efficient at high heart rates when automated pitch adaptation, especially in combination with ECG-based tube-modulation is used. However in clinical routine scanning for patients with higher heart rates

  11. Niche partitioning of marine group I Crenarchaeota in the euphotic and upper mesopelagic zones of the East China Sea.

    Science.gov (United States)

    Hu, Anyi; Jiao, Nianzhi; Zhang, Rui; Yang, Zao

    2011-11-01

    Marine group I Crenarchaeota (MGI) represents a ubiquitous and numerically predominant microbial population in marine environments. An understanding of the spatial dynamics of MGI and its controlling mechanisms is essential for an understanding of the role of MGI in energy and element cycling in the ocean. In the present study, we investigated the diversity and abundance of MGI in the East China Sea (ECS) by analysis of crenarchaeal 16S rRNA gene, the ammonia monooxygenase gene amoA, and the biotin carboxylase gene accA. Quantitative PCR analyses revealed that these genes were higher in abundance in the mesopelagic than in the euphotic zone. In addition, the crenarchaeal amoA gene was positively correlated with the copy number of the MGI 16S rRNA gene, suggesting that most of the MGI in the ECS are nitrifiers. Furthermore, the ratios of crenarchaeal accA to amoA or to MGI 16S rRNA genes increased from the euphotic to the mesopelagic zone, suggesting that the role of MGI in carbon cycling may change from the epipelagic to the mesopelagic zones. Denaturing gradient gel electrophoretic profiling of the 16S rRNA genes revealed depth partitioning in MGI community structures. Clone libraries of the crenarchaeal amoA and accA genes showed both "shallow" and "deep" groups, and their relative abundances varied in the water column. Ecotype simulation analysis revealed that MGI in the upper ocean could diverge into special ecotypes associated with depth to adapt to the light gradient across the water column. Overall, our results showed niche partitioning of the MGI population and suggested a shift in their ecological functions between the euphotic and mesopelagic zones of the ECS.

  12. An investigation into CT radiation dose variations for head examinations on matched equipment

    International Nuclear Information System (INIS)

    Zarb, Francis; Foley, Shane; Toomey, Rachel; Rainford, Louise; Holm, Susanne; Evanoff, Michael G.

    2016-01-01

    This study investigated radiation dose and image quality differences for computed tomography (CT) head examinations across centres with matched CT equipment. Radiation dose records and imaging protocols currently employed across three European university teaching hospitals were collated, compared and coded as Centres A, B and C from specification matched CT equipment models. Patient scans (n = 40) obtained from Centres A and C were evaluated for image quality, based on the visualisation of Commission of European Community (CEC) image quality criteria using visual grading characteristic (VGC) analysis, where American Board of Radiology examiners (n = 11) stated their confidence in identifying anatomical criteria. Mean doses in terms of CT dose index (CTDI vol -mGy) and dose length product (DLP-mGy cm) were as follows: Centre A-33.12 mGy and 461.45 mGy cm; Centre B -101 mGy (base)/32 mGy (cerebrum) and 762 mGy cm and Centre C-71.98 mGy and 1047.26 mGy cm, showing a significant difference (p ≤ 0.05) in DLP across centres. VGC analysis indicated better visualisation of CEC criteria on Centre C images (VGC AUC 0.225). All three imaging protocols are routinely used clinically, and image quality is acceptable in each centre. Clinical centres with identical model CT scanners have variously customised their protocols achieving a range of dose savings and still resulting in clinically acceptable image quality. (authors)

  13. Long-Term Musical Group Interaction Has a Positive Influence on Empathy in Children

    Science.gov (United States)

    Rabinowitch, Tal-Chen; Cross, Ian; Burnard, Pamela

    2013-01-01

    Musical group interaction (MGI) is a complex social setting requiring certain cognitive skills that may also elicit shared psychological states. We argue that many MGI-specific features may also be important for emotional empathy, the ability to experience another person's emotional state. We thus hypothesized that long-term repeated participation…

  14. Evaluation of radiation dose during the percutaneous angioplasty for arteriovenous shunt assembling

    Science.gov (United States)

    Ting, Chien-Yi; Wu, Wen-Shiann; Tang, Kuo-Ting; Wang, Hsin-Ell; Lin, Chun-Chih

    2017-11-01

    Percutaneous angioplasty (PTA) for dysfunctional hemodialysis is usually performed by radiologists, but not cardiologists, in Taiwan, so that the radiation dose in patients and physicians are usually unknown and related studies are rare. In this study, we are pioneering an investigation into the radiation dose in percutaneous angioplasty for arteriovenous shunt assembling and the effect of RADPAD device, a lead-free surgical drape containing Bi and Ba, on the decrease of a radiation dose in the non-targeted organs of the patient and also the operator. The radiation dose in a typical digital subtraction angiography (DSA) by the PTA protocol under a fixed field of view (FOV), was measured with optically simulated luminescent dosimeters arranged in a PIXY RS-102 anthropomorphic phantom. The results indicate that there is a significant dose reduction at the hands (0.022±0.002 mGy before treatment vs. 0.014±0.001 mGy after treatment; P=0.021), but not at the lens (0.027±0.003 mGy before treatment vs. 0.018±0.001 mGy after treatment; P=0.058), and the gonads (0.026±0.003 mGy before treatment vs. 0.020±0.001 mGy after treatment; P=0.058), of the cardiologist/operator after treatment with the RADPAD drape. At the patient's abdomen, the dose significantly decreased from 1.597±0.104 mGy to 0.031±0.002 mGy (PRADPAD shield. For the chest, lens and thyroid in the patient, the doses were respectively 0.154±0.100 mGy (compared to 0.049±0.001 mGy after treated with the RADPAD drape; P=0.0002), 0.066±0.001 mGy (compared to 0.021±0.001 mGy after the RADPAD treatment; P=0.009), and 0.208±0.002 mGy (compared to 0.042±0.003 mGy after shielded with the RADPAD drape; PRADPAD drape significantly reduced radiation exposure to the patient during the PTA for the arteriovenous shunt assembling, which is suggested should be applied to the current cardiac catheterization.

  15. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  16. The effects of low dose radiation (LDR) on mice of immune function

    International Nuclear Information System (INIS)

    Feng Li; Deng Daping

    2007-01-01

    Objective: To find out the Effects of Low Dose Radiation(LDR) on mice of immune function. Methods: Through flow cytometry to observe and analyse the effects of the leukomonocyte. Through immunohistochemistry to study IL-2, TNF-α. Results: At dose of 100mGy the stimulative effect on CD 4 + cells, CD 8 + cells and NK activity was higher than that at other doses. At dose of 500mGy leukomonocyte activity was lower. At dose of 100mGy, the colorations about IL-2, TNF-α deepen. Conclusion: LDR could stimulate immune function, especially at dose of 100mGy. while at dose of 500mGy, radiation could restrain the leukomonocyte activity. (authors)

  17. Measurement and estimation of maximum skin dose to the patient for different interventional procedures

    International Nuclear Information System (INIS)

    Cheng Yuxi; Liu Lantao; Wei Kedao; Yu Peng; Yan Shulin; Li Tianchang

    2005-01-01

    Objective: To determine the dose distribution and maximum skin dose to the patient for four interventional procedures: coronary angiography (CA), hepatic angiography (HA), radiofrequency ablation (RF) and cerebral angiography (CAG), and to estimate the definitive effect of radiation on skin. Methods: Skin dose was measured using LiF: Mg, Cu, P TLD chips. A total of 9 measuring points were chosen on the back of the patient with two TLDs placed at each point, for CA, HA and RF interventional procedures, whereas two TLDs were placed on one point each at the postero-anterior (PA) and lateral side (LAT) respectively, during the CAG procedure. Results: The results revealed that the maximum skin dose to the patient was 1683.91 mGy for the HA procedure with a mean value of 607.29 mGy. The maximum skin dose at the PA point was 959.3 mGy for the CAG with a mean value of 418.79 mGy; While the maximum and the mean doses at the LAT point were 704 mGy and 191.52 mGy, respectively. For the RF procedure the maximum dose was 853.82 mGy and the mean was 219.67 mGy. For the CA procedure the maximum dose was 456.1 mGy and the mean was 227.63 mGy. Conclusion: All the measured dose values in this study are estimated ones which could not provide the accurate maximum value because it is difficult to measure using a great deal of TLDs. On the other hand, the small area of skin exposed to high dose could be missed as the distribution of the dose is successive. (authors)

  18. Effect of gamma irradiation at intermediate doses on the performance of reverse osmosis membranes

    International Nuclear Information System (INIS)

    Combernoux, Nicolas; Labed, Véronique; Schrive, Luc; Wyart, Yvan; Carretier, Emilie; Moulin, Philippe

    2016-01-01

    The goal of this study is to explain the degradation of Polyamide (PA) composite reverse osmosis membrane (RO) in function of the irradiation dose. Irradiations were performed with a gamma 60 Co source in wet conditions and under oxygen atmosphere. For different doses of 0.2 and 0.5 MGy with a constant dose rate of 0.5 kGy h −1 , RO membranes performances (NaCl retention, permeability) were studied before and after irradiation. ATR-FTIR, ion chromatography and gas chromatography were used to characterize structural modification. Results showed that the permeability of RO membranes irradiated at 0.2 MGy exhibited a small decrease, related to scissions of the PVA coating. However, retention did not change at this dose. At 0.5 MGy, permeability showed a large increase of a factor around 2 and retention began to decrease from 99% to 95%. Chromatography measurements revealed a strong link between permselectivity properties variation, ion leakage and oxygen consumption. Add to ATR-FTIR observations, these results emphasized that the cleavages of amide and ester bonds were observed at 0.5 MGy, more precisely the loss of hydrogen bonds between polyamide chains. By different analysis, modifications of the polysulfone layer occur until a dose of 0.2 MGy. - Highlights: • Irradiation of RO membranes at intermediate dose (0.2 and 0.5 MGy). • For a dose rate of 0.5 kGy h −1 RO membranes are radiation resistant until 0.2 MGy. • Cleavages of polymer bonds in the active layer at 0.5 MGy. • Decrease in permselectivity properties of the membrane at 0.5 MGy. • High oxygen consumption between 0.2 and 0.5 MGy related to the membranes degradation.

  19. Report of questionnaire concerning the conditions and exposure doses at thoracoabdominal radiography and CT

    International Nuclear Information System (INIS)

    2009-01-01

    Japan Association of Radiological Technologists, at 2 years after its presentation of the Guideline for Medical Radiation Exposure (2006), made a questionnaire in the title on its homepage on Nov. 6-Dec. 5, 2008, and this paper is its report. The questionnaire asked the conditions and exposure doses at thoracoabdominal radiography and CT: in the former, asked were conditions like the machine/detector, tube voltage, filter, incident angle, entrance plane dose (EPD) (mGy) etc., and 237 facilities including 56 public hospitals and 15 universities answered. EPD calculated by numerical dose determination was found to be 0.22 and 0.76 mGy at the frontal and lateral thoracic projection, respectively, which were less than the upper limit defined in International Atomic Energy Agency (IAEA) guidance (0.4 and 1.5 mGy). However, doses in 6 and 2.6% of facilities at the respective projection exceeded the IAEA levels. EPD at the frontal abdominal projection calculated was 2.22 mGy, and all facilities met with the IAEA demand level (<10 mGy). In the CT questionnaire, conditions asked were the machine manufacturer/brand, scanning mode and range, tube voltage, rotation time, beam width and pitch, slice width, CTDIvol (CT Dose Index weighted/pitch) (mGy) and so on, which 212 facilities involving 58 public hospitals and 14 universities answered. CTDIvol was found to be 91.7 mGy at head CT which greatly exceeded the maximal levels of International Commission of Radiological Protection (ICRP), IAEA and the Association (60, 50 and 65 mGy, respectively). CTDIvol at thoracic CT was 15.2 mGy (no standard upper limit at present), and at abdominal CT, 20.0 mGy (the same as the Association level). The latter suggested the suitable dose setting at this CT. Thus the problem at head CT was much highlighted here. (K.T.)

  20. Eestist

    Index Scriptorium Estoniae

    1999-01-01

    Vabariigi aastapäeva tähistamisest Põlvamaal, intervjuu Miliza Korjuse tütrega, Anne Veski on Venemaal endiselt populaarne, kuhu panna laulma J. Carreras, lätlased domineerisid Valga klaveriansamblite festivalil, Rein Rannapi kontserdi järelkajad Järvamaal ja Virumaal, Viruma orkestritest,Avo Tamme laulud, mitmest huvitavast muusikust maakondades, Saaremaa folkloristide ettevõtmistest ja rahvapilliõpetusest lastele Viljandis, kitarristidest-muuikutest ja Viljandi kontseriuudiseid

  1. Implementation of Simple and Functional Web Applications at the Alaska Volcano Observatory Remote Sensing Group

    Science.gov (United States)

    Skoog, R. A.

    2007-12-01

    Web pages are ubiquitous and accessible, but when compared to stand-alone applications they are limited in capability. The Alaska Volcano Observatory (AVO) Remote Sensing Group has implemented web pages and supporting server software that provide relatively advanced features to any user able to meet basic requirements. Anyone in the world with access to a modern web browser (such as Mozilla Firefox 1.5 or Internet Explorer 6) and reasonable internet connection can fully use the tools, with no software installation or configuration. This allows faculty, staff and students at AVO to perform many aspects of volcano monitoring from home or the road as easily as from the office. Additionally, AVO collaborators such as the National Weather Service and the Anchorage Volcanic Ash Advisory Center are able to use these web tools to quickly assess volcanic events. Capabilities of this web software include (1) ability to obtain accurate measured remote sensing data values on an semi- quantitative compressed image of a large area, (2) to view any data from a wide time range of data swaths, (3) to view many different satellite remote sensing spectral bands and combinations, to adjust color range thresholds, (4) and to export to KML files which are viewable virtual globes such as Google Earth. The technologies behind this implementation are primarily Javascript, PHP, and MySQL which are free to use and well documented, in addition to Terascan, a commercial software package used to extract data from level-0 data files. These technologies will be presented in conjunction with the techniques used to combine them into the final product used by AVO and its collaborators for operational volcanic monitoring.

  2. IZBOLJŠAVA STATISTIČNEGA NADZORA PROCESA V PODJETJU VIP - VIRANT D.O.O.

    OpenAIRE

    Dolžan, Tomaž

    2014-01-01

    Tema diplomske naloge so kabelski snopi oziroma povezave, ki se uporabljajo v namen avtomobilske industrije. Pri obravnavanih kabelskih snopih gre za problematiko statističnega nadzora proizvodnega procesa. V nalogi smo se ukvarjali z izboljšavo dosedanjega statističnega nadzora proizvodnega procesa in pri tem dobili tudi konkretne podatke za dva parametra, katera smo merili. Meritve smo opravljali na podlagi jemanja vzorcev iz proizvodnega procesa. Opisali smo preteklo stanje statističnega n...

  3. Resolution enhancement of robust Bayesian pre-stack inversion in the frequency domain

    Science.gov (United States)

    Yin, Xingyao; Li, Kun; Zong, Zhaoyun

    2016-10-01

    AVO/AVA (amplitude variation with an offset or angle) inversion is one of the most practical and useful approaches to estimating model parameters. So far, publications on AVO inversion in the Fourier domain have been quite limited in view of its poor stability and sensitivity to noise compared with time-domain inversion. For the resolution and stability of AVO inversion in the Fourier domain, a novel robust Bayesian pre-stack AVO inversion based on the mixed domain formulation of stationary convolution is proposed which could solve the instability and achieve superior resolution. The Fourier operator will be integrated into the objective equation and it avoids the Fourier inverse transform in our inversion process. Furthermore, the background constraints of model parameters are taken into consideration to improve the stability and reliability of inversion which could compensate for the low-frequency components of seismic signals. Besides, the different frequency components of seismic signals can realize decoupling automatically. This will help us to solve the inverse problem by means of multi-component successive iterations and the convergence precision of the inverse problem could be improved. So, superior resolution compared with the conventional time-domain pre-stack inversion could be achieved easily. Synthetic tests illustrate that the proposed method could achieve high-resolution results with a high degree of agreement with the theoretical model and verify the quality of anti-noise. Finally, applications on a field data case demonstrate that the proposed method could obtain stable inversion results of elastic parameters from pre-stack seismic data in conformity with the real logging data.

  4. Ion Kinetics in the Solar Wind: Coupling Global Expansion to Local Microphysics

    Czech Academy of Sciences Publication Activity Database

    Matteini, L.; Hellinger, Petr; Landi, S.; Trávníček, Pavel M.; Velli, M.

    2012-01-01

    Roč. 172, 1-4 (2012), s. 373-396 ISSN 0038-6308 Grant - others:ESA(XE) PECS 98068; AVO(CZ) IAA300420702 Program:IA Institutional research plan: CEZ:AV0Z10030501; CEZ:AV0Z30420517 Keywords : solar wind * ion kinetics * numerical simulations Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 5.519, year: 2012

  5. Investigating behavior changes of laying hens molted by high dietary zinc

    OpenAIRE

    Smayyeh Salari; Somayyeh Salari

    2016-01-01

    Introduction The commercial egg industry commonly uses induced molt procedures to rejuvenate flocks for a second or third laying cycle. Molting may be induced by feed withdrawal for up to 10 days (7), water withdrawal for 2 days (19), or both, along with a reduction of day length (14). Such programs cause concern about animal welfare because it is thought that they may be harmful to hens (28). Given the concerns for potential bird stress, various methods of nutrient restriction that would avo...

  6. Selection of UAS Personnel (SUPer) Phase I Report: Identification of Critical Skills, Abilities, and Other Characteristics and Recommendations for Test Battery Development

    Science.gov (United States)

    2014-11-20

    UAS/RPA AVOs is driving reassignment of manned aircraft pilots into unmanned piloting jobs, which may result in poor P- E Fit. Other Potential...Tasking Test (MTT) Test Description The USAF Multi-Tasking Test, based on a test originally sponsored by the US Navy, assesses cognitive multitasking ...0.26 0.20 N/A Favorable TBAS TBAS MultiTasking (Combination Joystick and Rudder Test) 0.25 0.00 N/A Favorable

  7. IT ei loe / Nicholas G. Carr

    Index Scriptorium Estoniae

    Carr, Nicholas G.

    2003-01-01

    Harvard Business Review endise toimetaja arvates on infotehnoloogia (IT) strateegiline tähtsus ettevõtetes oluliselt vähenenud ning innovaatilised IT lahendused ei anna enam konkurentsieeliseid, mille tõttu peab muutuma ka juhtide suhtumine IT riskidesse, investeeringutesse ja juhtimisse. Vt. samas: Kuidas vältida üleinvesteerimist IT-sse?; Liiga palju head; Mis saab müüjatest?; Uued reeglid IT juhtimises. Kommenteerivad Henn Sarv, Avo Kokk, Olli Heinonen ja Jüri Kaljundi

  8. Tänukiri

    Index Scriptorium Estoniae

    2000-01-01

    Tulemusliku töö eest tänukirjaga autasustatud TPÜ töötajad ja külalislektorid: Angela Arraste, Cécile Eliziere, Margus Harak, Aili Kants, Edgar Karofeld, Aili Kelam, Wolf Peter Klein, Jüri Kruusvall, Marek Kuzmin, Viivi Maanso, Avo Petrauts, Anne Rooste, Helve Siivo, Leida Talts, Aili Tamm, Anu Toots, Ülo Ugaste, Urve Väljas, Paul Ruudi / allikas : TPÜ rektori käskkiri, 13. oktoober 2000

  9. Nähtamatu naise nähtav panus / Eerik Purje ; fotod: V. Sarapuu

    Index Scriptorium Estoniae

    Purje, Eerik, 1927-

    2006-01-01

    17. oktoobri õhtul Tartu College´i saalis toimunud pidulikust õhtust, mis oli pühendatud Vaiki Toile, esitades Roman Toi loomingut ja tähistades Romani 90. sünnipäeva. Õhtut juhtis Avo Kittask, esinesid Estonia Koor, Toronto Eesti Meeskoor, lauluansambel Helin, klaveril saatis Asta Ballstadt, koore juhatasid Margit Viia-Maiste, Ingrid Silm, Charles Kipper. Avati kunstnik Josef Milczarski portree juubilarist

  10. Study on human mesenchymal stem cells from bone marrow pretreated with low dose radiation

    International Nuclear Information System (INIS)

    Yang Yan; Wang Guangjun; Wang Juan

    2008-01-01

    Objective: To study effects of human bone marrow mesenchymal stem cells (hBM-MSC) from bone marrow pretreated with low dose radiation (LDR). Methods: The cells were the hBM-MSC. They were exposed to X rays at the dose of 50 mGy, 75 mGy, 100 mGy (dose rate 12.5 mGy/min). The growth curve, cell cycle and apoptosis of hBM-MSC treated by LDR were investigated. The content changes of stem cell factor(SCF), interleukin-6 (IL-6), macrophage colony stimulating factor(M-CSF) secreted by hBM-MSC after treated by LDR were determined by enzyme linked immunosorbent assay method. Results: The growth rates of hBM-MSC treated by LDR obviously increase from 72 h. The cell cycle and apoptosis were examined with FORTRAN Atomatic Checkout Systom. The results show that the G 0 /G 1 stage cells decrease after exposure to LDR, the percent of G 0 /G 1 stage cells of 75 mGy at 72 h is the lowest(30.86%). However, the S stage cells percentage gradually increase at 48 h and 72 h. The most one is 75 mGy group at 72 h, which reaches to 68.88%. The apoptosis percentages have increased tendency at 24 h and 48h in all dose groups, especially in 100 mGy at 24 h(25.99%), while have decreased tendency at 72 h and the most decreased group is the 50 mGy(6.8%), transient enhancement of apoptosis in the early stage and soon being decreased. The contents of SCF have increased tendency at 24 h, 48 h. As for IL-6, the contents in different dose groups at 24 h and 48 h have up-regulation. These groups, 50 mGy at 24 h, 48 h, 75 mGy at 24 h, 48 h, 100 mGy at 24 h have statistical difference compared with their control groups respectively. The content of IL-6 has greatest enhancement at dose of 50 mGy. The contents of M-SCF in all the groups at 24 h, 48 h and 72 h except for the 50 mGy dose at 72 h have also been found increased. The greatest increased content occur in the 75 mGy dose group at 72 h. Conclusion: This conclusion show that LDR has hormesis effect on hBM-MSC in cell growth, cell cycle and content

  11. Ultralow-dose CT of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction and model-based iterative reconstruction: 2D and 3D image quality.

    Science.gov (United States)

    Widmann, Gerlig; Schullian, Peter; Gassner, Eva-Maria; Hoermann, Romed; Bale, Reto; Puelacher, Wolfgang

    2015-03-01

    OBJECTIVE. The purpose of this article is to evaluate 2D and 3D image quality of high-resolution ultralow-dose CT images of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard filtered backprojection (FBP). MATERIALS AND METHODS. A formalin-fixed human cadaver head was scanned using a clinical reference protocol at a CT dose index volume of 30.48 mGy and a series of five ultralow-dose protocols at 3.48, 2.19, 0.82, 0.44, and 0.22 mGy using FBP and ASIR at 50% (ASIR-50), ASIR at 100% (ASIR-100), and MBIR. Blinded 2D axial and 3D volume-rendered images were compared with each other by three readers using top-down scoring. Scores were analyzed per protocol or dose and reconstruction. All images were compared with the FBP reference at 30.48 mGy. A nonparametric Mann-Whitney U test was used. Statistical significance was set at p ASIR-100 at 3.48 mGy, ASIR-100 at 2.19 mGy, and MBIR at 0.82 mGy. MBIR at 2.19 and 3.48 mGy scored statistically significantly better than the FBP reference (p = 0.032 and 0.001, respectively). For 3D images, the FBP reference at 30.48 mGy did not statistically significantly differ from all reconstructions at 3.48 mGy; FBP and ASIR-100 at 2.19 mGy; FBP, ASIR-100, and MBIR at 0.82 mGy; MBIR at 0.44 mGy; and MBIR at 0.22 mGy. CONCLUSION. MBIR (2D and 3D) and ASIR-100 (2D) may significantly improve subjective image quality of ultralow-dose images and may allow more than 90% dose reductions.

  12. Dosimetry for Patients undergoing Radiographic Examinations in Sudan

    International Nuclear Information System (INIS)

    Halato, M.A.; Kafi, S.T.; Ahmed, A.M.; Sid Ahamed, F.A.; Ibrahim, Z.; Suliman, M.F.; Suliman, I.I.

    2009-01-01

    In this study we estimated the entrance skin doses ESDs for patients undergoing selected diagnostic X -ray examinations in two large public hospitals in Khartoum state, Sudan. The study included the examinations of the chest posterior-anterior (PA) , skull antero-posterior (AP), skull Lateral (LAT) , Lumber spine AP/LAT, abdomen Intravenous urogram (IVU) and Pelvis AP. Totally, 241 patients were included in this study. ESDs were estimated from patients specific exposure parameters using established relation between output (μ Gy/mAs) and tube voltage (kVp). The estimated ESDs ranged from 0.18 - 1.05 mGy for chest PA, 0.98 - 3.48 mGy for Skull (AP), 0.66 - 2.75 mGy for skull (LAT), 1.22 - 4.35 mGy for abdomen (IVU), 1.18 - 5.75 mGy for Pelvis, 1.52 - 5.01 mGy Lumbar spine AP and 2.48 - 10.41 mGy for Lumbar spine (LAT). These values compare well with the international reference dose levels. This study provides additional data that can help the regulatory authority to establish reference dose level for diagnostic radiology in Sudan

  13. The Third International Intercomparison on EPR Tooth Dosimetry: Part 2, final analysis

    International Nuclear Information System (INIS)

    Wieser, A.; Debuyst, R.; Fattibene, P.; Meghzifene, A.; Onori, S.; Bayankin, S. N.; Brik, A.; Bugay, A.; Chumak, V.; Ciesielski, B.; Hoshi, M.; Imata, H.; Ivannikov, A.; Ivanov, D.; Junczewska, M.; Miyazawa, C.; Penkowski, M.; Pivovarov, S.; Romanyukha, A.; Romanyukha, L.; Schauer, D.; Scherbina, O.; Schultka, K.; Sholom, S.; Skvortsov, V.; Stepanenko, V.; Thomas, J. A.; Tielewuhan, E.; Toyoda, S.; Trompier, F.

    2006-01-01

    The objective of the Third International Intercomparison on EPR Tooth Dosimetry was to evaluate laboratories performing tooth enamel dosimetry <300 mGy. Final analysis of results included a correlation analysis between features of laboratory dose reconstruction protocols and dosimetry performance. Applicability of electron paramagnetic resonance (EPR) tooth dosimetry at low dose was shown at two applied dose levels of 79 and 176 mGy. Most (9 of 12) laboratories reported the dose to be within 50 mGy of the delivered dose of 79 mGy, and 10 of 12 laboratories reported the dose to be within 100 mGy of the delivered dose of 176 mGy. At the high-dose tested (704 mGy) agreement within 25% of the delivered dose was found in 10 laboratories. Features of EPR dose reconstruction protocols that affect dosimetry performance were found to be magnetic field modulation amplitude in EPR spectrum recording, EPR signal model in spectrum deconvolution and duration of latency period for tooth enamel samples after preparation. (authors)

  14. IN VITRO CULTURE OF HOLOPARASITE Rafflesia arnoldii R. Brown

    Directory of Open Access Journals (Sweden)

    Lazarus Agus Sukamto

    2010-07-01

    Full Text Available Potongan kuncup bunga digunakan sebagai eksplan yang ditumbuhkan pada media dasar Murashige and Skoog (MS dengan tambahan 0; 0.1; 0.5; 1 and 5 mg/I 2,4-D atau Picloram dan 2 g/I Phytagel. Eksplan tumbuh menjadi kalus pada media yang ditambahkan 0,1 dan 1 mg/I 2,4-D atau 0,5 dan 1 mg/I Picloram. Kultur kalus tersebut dipelihara pada media MS + 1 mg/I 2,4-D. Kemudian kalus ditumbuhkan pada medium dengan penambahan 1, 3, 5 dan 10 mg/I 2,4-D atau Picloram. Setelah dua bulan 66,67-100% kultur membentuk kalus. Semua kalus berstruktur kompak. Beberapa kalus yang diperlakuan dengan 5-10 mg/I 2,4-D menumbuhkan benang-benang putih pada permukaannya. Perlakuan Picloram menghasilkan kalus yang lebih banyak, tetapi 2,4-D menghasilkan kualitas kalus yang lebih baik. Kalus R. arnoldii tidak membentuk somatik embrio dengan penambahan 0,1 mg/I Zeatin dalam media kultur. Ini adalah laporan yang pertama kali tentang pembentukan kalus dari kultur R. arnoldii secara in vitro.

  15. Occupational and patient exposure in coronary angiography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Gafar, R.; Babikir, E.; Alsafi, K.; Suliman, I.I.

    2014-01-01

    Cardiac catheterization is the gold standard in the diagnosis and management of coronary artery diseases. The objectives of this study were to evaluate the radiation dose of patients and staff during cardiology procedures. Staff was monitored using thermoluminescence dosimeter (TLD) chips for 86 procedures. The mean patient dose was 2813.6 µGy m 2 and the mean fluoroscopic time was 4.8 min. The mean radiation doses for cardiologists were 0.9 mGy for the forehead, 0.92 mGy for the thyroid, 1.38 mGy for the chest, 1.28 mGy for the waist and 1.41 mGy for the hand. The mean radiation doses for assistants were 0.72 mGy for the chest, 0.82 mGy for the hand. High patient and staff exposure is due to lack of experience and protective equipment, exacerbated by a high workload. Interventional procedures remain operator dependent; therefore, continuous training is crucial. - Highlights: • Patients and staff radiation doses were evaluated during coronary angiography procedures. • Radiation doses were measured using calibrated TLD GR200A. • Radiation doses to patients and staff are comparable with previous studies. • Patient radiation doses fall below the threshold for radiation-induced skin injuries

  16. Determination of gonad, eye and bone marrow doses with EMI-5005 head and whole body scans

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Iwata, Takeo; Furuya, Yoshiro; Maruyama, Takashi; Hashizume, Tadashi.

    1979-01-01

    Dose determinations of tissues and organs during head and whole body scanning with an EMI computed tomographic equipment have been carried out using a Rando woman phantom. The surface dose on the phantom was measured with a Sakura lith Contact film dosimeter system. The absorbed doses in the eyes, thyroids, ovaries and the bone marrow were measured with a thermoluminescent dosimeter. The resultant surface doses for head scanning were 2.8 rad (28 mGy) per scan at maximum and 0.26 rad (2.6 mGy) per scan at minimum, and the doses for whole body scanning were 2.7 rad (27 mGy) per scan at maximum and 0.1 rad (1.0 mGy) per scan at minimum. For the complete gynecological scanning consisting of 8 slices, the eye, thyroid, ovary and the bone marrow dose was 2.4 mrad (24 μGy), 3.5 mrad (35 μGy), 500 mrad (5 mGy) and 225 mrad (2.25 mGy), respectively. And, for a typical head scanning consisting of 5 slices, the eye, thyroid, ovary and the bone marrow dose was 1400 mrad (14 mGy), 46 mrad (460 μGy), 0.60 mrad (6 μGy) and 73 mrad (730 μGy), respectively. (author)

  17. Measurements of radiation dose to patients undergoing some common radiographic x-ray examinations in Wad Madani hospitals

    International Nuclear Information System (INIS)

    Mohammedzein, T. S.

    2009-12-01

    The aim of this study was to assess patient doses in most common radiographic x-ray examinations in Wad Madani hospitals of Al Gazera State. The examination parameters of 388 radiographs were used to calculate the Entrance Surface Air Kerma (ESAK) of patients undergoing skull (AP and LAT), chest (PA), pelvis (AP), abdomen (AP) and lumbar spin (AP and LAT) in six major hospitals. Hospital mean ESAKs estimated range from 0.0729-0.69 mGy for chest PA, 0.338-6.64 mGy for skull PA, 0.195-5.8 mGy for skull LAT, 0.595-3.42 mGy for pelvis AP, 0.772-6.31 mGy for lumbar spine AP, 2.1-15.2 mGy for lumbar spine LAT and 0.742-5.79 mGy for abdomen. This data will be useful for the formulation of national reference levels as recommended by International Atomic Energy Agency (IAEA). (Author)

  18. Low-dose neutron dose response of zebrafish embryos obtained from the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility

    International Nuclear Information System (INIS)

    Ng, C.Y.P.; Kong, E.Y.; Konishi, T.; Kobayashi, A.; Suya, N.; Cheng, S.H.; Yu, K.N.

    2015-01-01

    The dose response of embryos of the zebrafish, Danio rerio, irradiated at 5 h post fertilization (hpf) by 2-MeV neutrons with ≤100 mGy was determined. The neutron irradiations were made at the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility in the National Institute of Radiological Sciences (NIRS), Chiba, Japan. A total of 10 neutron doses ranging from 0.6 to 100 mGy were employed (with a gamma-ray contribution of 14% to the total dose), and the biological effects were studied through quantification of apoptosis at 25 hpf. The responses for neutron doses of 10, 20, 25, and 50 mGy approximately fitted on a straight line, while those for neutron doses of 0.6, 1 and 2.5 mGy exhibited neutron hormetic effects. As such, hormetic responses were generically developed by different kinds of ionizing radiations with different linear energy transfer (LET) values. The responses for neutron doses of 70 and 100 mGy were significantly below the lower 95% confidence band of the best-fit line, which strongly suggested the presence of gamma-ray hormesis. - Highlights: • Neutron dose response was determined for embryos of the zebrafish, Danio rerio. • Neutron doses of 0.6, 1 and 2.5 mGy led to neutron hormetic effects. • Neutron doses of 70 and 100 mGy accompanied by gamma rays led to gamma-ray hormesis

  19. THE ECONOMIC AND PSYCHO-SOCIAL EXPERIENCES AND COPING RESOURCES OF FAMILY MEMBERS CARING FOR PEOPLE LIVING WITH AIDS IN THEIR HOMES IN BHAMBAYI, KWAZULU-NATAL, SOUTH AFRICA

    Directory of Open Access Journals (Sweden)

    Raniga, Tanusha

    2013-05-01

    Full Text Available There is empirical evidence that families have responded with much resilience and compassion to caring for persons living with AIDS (PWAs in their homes (Engelbrecht & Kasiram, 2007; Sekokotla & Mturi, 2004; Simpson & Raniga, 2004. At the same time families in poverty-stricken communities are increasingly struggling and failing to provide optimally for the economic and psycho-social needs of PWAs who are in their care (Bartlett & Finkbeiner, 2006; Darling, Olmstead & Tiggleman, 2009. It is not surprising, however, at a time when the devastating effects of HIV and AIDS are all too evident, that international organisations, national governments and civil society organisations recognise the invaluable role played by extended family members as support caregivers in the care of those terminally ill with AIDS.

  20. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada

    International Nuclear Information System (INIS)

    Engelbrecht, J.; Kavouras, I.; Campbell, D.; Campbell, S.; Kohl, S.; Shafer, D.

    2009-01-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program

  1. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    International Nuclear Information System (INIS)

    Engelbrecht, J.; Kavouras, I.; Campbell, D.; Campbell, S.; Kohl, S.; Shafer, D.

    2009-01-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program

  2. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada

    International Nuclear Information System (INIS)

    Engelbrecht, J.; Kavouras, I.; Campbell, D.; Campbell, S.; Kohl, S.; Shafer, D.

    2009-01-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program

  3. Estimation of entrance dose during selected fluoroscopic examinations in some hospitals in Khartoum state

    International Nuclear Information System (INIS)

    Mohammed, Heba Abdalkareem Osman

    2016-01-01

    A diagnostic fluoroscopy is a modality that involves visualizing the anatomy using radiation in real time. Therefore, patients doses have a potential for being great, increasing the chance of the radiation induced carcinogenesis. The objective of this study was to determine the mean entrance surface dose (ESD) from selected fluoroscopic examinations namely, hysterosalpingography (HSG) and ascendingurethogram (ASU) in three hospitals in Khartoum State. A total of 87 and 110 patents for HSG and ASU respectively were examined. The data were collected over four months. The mean ESD for patients who underwent HSG were 16.2 mGy, 20.6 mGy and 25.9 mGY respectively, while the ESD for patient who underwent ascendingurethrogram for AP view were 3.5mGy, 2.9mGy and 11.9mGy and for OB view 15.9 mGy, 18.3 mGy and 25.4 mGy. Patient doses were calculated using mathematical equation and the results were compared with the ESDs calculated using mathematical equation and the results were found to be comparable with the ESDs reported in previous studies and within the guidance level established by the ICRP. Fluoroscopy time, operator skills, x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported in the measured ESDs. The study demonstrated the need for standardization of techniques throughout the hospitals and suggested that there ia a need to optimize the procedures.(Author)

  4. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  5. Validation of the mother-generated index in Iran: A specific postnatal quality-of-life instrument

    Directory of Open Access Journals (Sweden)

    Roghayeh Khabiri

    2013-01-01

    Full Text Available Background: The mother-generated index (MGI is one of only a few existing specific questionnaires for assessing the postnatal quality of life (QoL. MGI is a single-form questionnaire that asks postnatal mothers to specify up to eight areas of their lives which have been affected by giving birth to a baby. Using this tool, it is possible to score and rank the QoL of mothers. This study aimed to validate the questionnaire for use in Iran. Methods : Forward translation was used to translate the questionnaire from English to Farsi (Persian. The questionnaire was then administered to a sample of postnatal women attending two teaching hospitals in Tehran, Iran. Face validity and criterion validity were performed to establish the validity for the Iranian version of the MGI. Face validity was assessed by asking women to indicate whether they understood the wording of the questions, how easy the questionnaire was, and so on. Criterion validity was examined using the Short Form 36-item (SF-36 Health Survey. It was hypothesized that the MGI would significantly correlate with the SF-36. Results: In all, 124 women were approached. Of these, 119 women were eligible and 96 women agreed to take part in the study. Face validity was good and all of the women found the MGI straightforward to complete; as criterion validity, the MGI scores and the subscales of the SF-36 were moderately correlated (for all subscales: Pearson r > 0.4; P < 0.001. The mean MGI primary score was 5.38 (SD = 3.05. Women who had comorbidity had significantly lower MGI scores than women without comorbidity (P = 0.04. Correlation between aggregate of comments and primary score was high (r = 0.68, P < 0.01. Conclusions: In general, the Iranian version of the MGI performed well and our data suggest that it is a valid measure to assess health-related QoL among postnatal women.

  6. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  7. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography

    International Nuclear Information System (INIS)

    Lopes, Cintya Carolina Barbosa

    2006-04-01

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  8. Preliminary evaluation of exposures of computerized tomography patients in Latin America: IAEA project RLA/9/67

    International Nuclear Information System (INIS)

    Kodlulovich, S.; Silveira, V.; Khoury, H.J.

    2013-01-01

    The aim of this study was to obtain preliminary values of reference levels in CT . Were sent to each country forms with information of radiological protection and routine CT protocols. The CT dose index and absorbed dose to organs was estimated from the technical data for each equipment . The results showed that the total number of examinations performed 92 % are adult patients and 8 % are children. The most frequent examination of the skull was adult (40 % ) and abdomen for children (42 % ) . About the service , 67 % of the equipment are multicut and 76 % have specific protocols for pediatric patients. The CTDI vol values for head exams of adults vary between 2 and 352 mGy for pediatric patients under 1 year 1-191 mGy under 7 years old 5-335 mGy. For chest values ranged from 3 to 26 mGy for adults, between 1 and 89 mGy for children under 1 year and between 3-114 mGy for children between 1 and 7 years. Exams of the abdomen/pelvis of adults the range was 3-47 mGy , between 4-90 mGy for children under 1 year and between 2-31 mGy for children between 1 and 7 years. This study showed that although there are pediatric protocols, there is a wide variation in values of CTDl vol indicating a high potential for dose reduction. This result requires immediate action for optimization and implementation of diagnostic reference values in Latin America

  9. Preliminary evaluation of exposures of computerized tomography patients in Latin America: IAEA project RLA/9/67; Avaliacao preliminar das exposicoes de pacientes em tomografia computadorizada na America Latina: Projeto IAEA RLA/9/67

    Energy Technology Data Exchange (ETDEWEB)

    Kodlulovich, S.; Silveira, V. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Khoury, H.J. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamcnto de Energia Nuclear; and others

    2013-07-01

    The aim of this study was to obtain preliminary values of reference levels in CT . Were sent to each country forms with information of radiological protection and routine CT protocols. The CT dose index and absorbed dose to organs was estimated from the technical data for each equipment . The results showed that the total number of examinations performed 92 % are adult patients and 8 % are children. The most frequent examination of the skull was adult (40 % ) and abdomen for children (42 % ) . About the service , 67 % of the equipment are multicut and 76 % have specific protocols for pediatric patients. The CTDI{sub vol} values for head exams of adults vary between 2 and 352 mGy for pediatric patients under 1 year 1-191 mGy under 7 years old 5-335 mGy. For chest values ranged from 3 to 26 mGy for adults, between 1 and 89 mGy for children under 1 year and between 3-114 mGy for children between 1 and 7 years. Exams of the abdomen/pelvis of adults the range was 3-47 mGy , between 4-90 mGy for children under 1 year and between 2-31 mGy for children between 1 and 7 years. This study showed that although there are pediatric protocols, there is a wide variation in values of CTDl{sub vol} indicating a high potential for dose reduction. This result requires immediate action for optimization and implementation of diagnostic reference values in Latin America.

  10. Solid State Structure-Reactivity Studies on Bixbyites, Fluorites and Perovskites Belonging to the Vanadate, Titanate and Cerate Families

    Science.gov (United States)

    Shafi, Shahid P.

    This thesis primarily focuses on the systematic understanding of structure-reactivity relationships in two representative systems: bixbyite and related structures as well as indium doped CeO2. Topotactic reaction routes have gained significant attention over the past two decades due to their potential to access kinetically controlled metastable materials. This has contributed substantially to the understanding of solid state reaction pathways and provided first insights into mechanisms. Contrary to the widely used ex-situ methods, in-situ techniques including powder x-ray diffraction and thermogravimetric-differential thermal analysis have been employed extensively throughout this work in order to follow the reaction pathways in real time. Detailed analysis of the AVO3 (A = In, Sc) bixbyite reactivity under oxidative conditions has been carried out and a variety of novel metastable oxygen defect phases have been identified and characterized. The novel metastable materials have oxygen deficient fluorite structures and consequently are potential ion conductors. Structural aspects of the topotactic vs. reconstructive transformations are illustrated with this model system. The structure-reactivity study of AVO3 phases was extended to AVO3 perovskite family. Based on the research methodologies and results from AVO3 bixbyite reactivity studies a generalized mechanistic oxidation pathway has been established with a non-vanadium phase, ScTiO3 bixbyite. However, there is stark contrast in terms of structural stability and features beyond this stability limit during AVO3 and ScTiO3 bixbyite reaction pathways. A series of complex reaction sequences including phase separation and phase transitions were identified during the investigation of ScTiO3 reactivity. The two-step formation pathway for the fluorite-type oxide ion conductor Ce1-xInxO2-delta (0 ≤ x ≤ 0.3) is being reported. The formation of the BaCe1-xInxO 3-delta perovskites and the subsequent CO2-capture reaction

  11. Radiation Measurement And Risk Estimation For Pediatric Patients During Routine Diagnostic Examination

    International Nuclear Information System (INIS)

    Bushra, E.; Sulieman, A.; Osman, H.

    2011-01-01

    The aim of the present work was to evaluate Entrance Surface Dose (ESD) to the patient using Thermo luminescence dosimeters (TLD) during some common routine pediatrics X-ray examinations in main pediatrics hospitals in Sudan. ESD and Effective Dose (E) for pediatrics have been carried out for 250 patients undergoing five different examinations. The mean ESD ranged for neonates ranged between 0.17 mGy-0.30 mGy per radiograph with scattered thyroid dose 0.01 to 0.19 mGy. The risk of radiation induced cancer of was 0.13 x 10-6.

  12. Evaluation of patient exposure with Flat Panel Detector (FPD) in X-ray TV system

    International Nuclear Information System (INIS)

    Yamada, M.; Komiya, N.; Kawaguchi, A.; Suzuki, M.; Suzuki, Shoichi; Asada, Yasuki

    2008-01-01

    The use of flat-panel detector (FPD) systems in TV equipment for gastrointestinal tract examination is increasing. The use of FPD systems is believed to reduce the exposure dose. When our institution changed its TV equipment from an image intensifier (GE; MS90Tj) system to an FPD (Shimadzu; SONIALVISION safire DAR-3500) system, we measured the doses produced and carried out a comparative examination of the extent to which exposure could be reduced. Two TV systems were used. We used an analyzer to measure output waveform, tube voltage, and half-value layer (HVL), and an ionization chamber dosimeter to carry out dose-in-air measurements. Body thickness, number of image acquisitions, and fluoroscopy time are required for the calculation of entrance skin dose (ESD). We therefore measured body thicknesses in 1000 upper gastrointestinal tract (UGI) and barium enemas and obtained average body thicknesses for males and females by age group. Values used for number of image acquisitions and fluoroscopy times were the averages in our institution over a two-year period. When an I.I. system was used, the average ESD during UGI examination were 126.8 mGy fluoroscopy dose and 11.62 mGy imaging dose, for an average total dose of 138.42 mGy per examination. ESD during barium enema averaged 201.73 mGy fluoroscopy dose and 45.2 mGy imaging dose, for an average total dose of 246.92 mGy per examination. When an FPD system was used, the average ESD during UGI examination were 58.71 mGy fluoroscopy dose and 5.72 mGy imaging dose, for an average total dose of 64.43 mGy per examination. ESD during barium enema averaged 112.21 mGy fluoroscopy dose and 24.55 mGy imaging dose, for an average total dose of 136.76 mGy per examination. The use of an FPD system reduced both fluoroscopy dose and imaging dose by 50%. The number of TV systems equipped with FPD in Japan has increased from around 1300 in 2006 to around 1700 in 2007. The use of FPD systems can be expected to increase in future. This

  13. Application of low-dose radiation protocols in survey CT scans

    International Nuclear Information System (INIS)

    Fu Qiang; Liu Ting; Lu Tao; Xu Ke; Zhang Lin

    2009-01-01

    Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for chest, 80 kV, 10 mA for abdomen and 100 kV, 10 mA for lumbar. The values of ESD for phantom scan in default and optimized protocols were 0.38 mGy/0.16 mGy in head, 0.30 mGy/0.20 mGy in chest, 0.74 mGy/0.30 mGy in abdomen and 0.81 mGy/0.44 mGy in lumbar, respectively. Compared with default protocols, the optimized protocols reduced the radiation doses 59%, 33%, 59% and 46% in head, chest, abdomen and lumbar. When tube position changed from 0 degree to 180 degree, the ESD were 0.24 mGy/0.20 mGy for chest; 0.37 mGy/0.30 mGy for abdomen, and the radiation doses were reduced 20% and 17%. Conclusion: A certain amount of image noise is increased in low-dose protocols, but image quality is still acceptable without problem in CT localization. The reduction of radiation dose and the radiation harm to patients are the superiority. (authors)

  14. Positron annihilation and thermally stimulated current of electron beam irradiated polyetheretherketone

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Shigetaka; Shinyama, Katsuyoshi; Baba, Makoto [Hachinohe Inst. of Tech., Hachinohe, Aomori (Japan); Suzuki, Takenori

    1997-03-01

    Positron lifetime measurements were applied to electron beam irradiated poly(ether-ether-ketone). The lifetime, {tau}{sub 3}, of the ortho-positronium of unirradiated and 5 MGy irradiated specimen became rapidly longer above about 150degC. {tau}{sub 3} of 50 MGy and 100 MGy irradiated specimen was shorter than that of unirradiated one. Thermally stimulated current (TSC) decreased with increasing the dose before voltage application. In the case of voltage application, a TSC peak appeared and the peak value decreased with increased the dose. The correlation between the results of positron annihilation and TSC was investigated. (author)

  15. Breast Radiation Dose With CESM Compared With 2D FFDM and 3D Tomosynthesis Mammography.

    Science.gov (United States)

    James, Judy R; Pavlicek, William; Hanson, James A; Boltz, Thomas F; Patel, Bhavika K

    2017-02-01

    We aimed to compare radiation dose received during contrast-enhanced spectral mammography (CESM) using high- and low-energy projections with radiation dose received during 2D full field digital mammography (FFDM) and 3D tomosynthesis on phantoms and patients with varying breast thickness and density. A single left craniocaudal projection was chosen to determine the doses for 6214 patients who underwent 2D FFDM, 3662 patients who underwent 3D tomosynthesis, and 173 patients who underwent CESM in this retrospective study. Dose measurements were also collected in phantoms with composition mimicking nondense and dense breast tissue. Average glandular dose (AGD) ± SD was 3.0 ± 1.1 mGy for CESM exposures at a mean breast thickness of 63 mm. At this thickness, the dose was 2.1 mGy from 2D FFDM and 2.5 mGy from 3D tomosynthesis. The nondense phantom had a mean AGD of 1.0 mGy with 2D FFDM, 1.3 mGy with 3D tomosynthesis, and 1.6 mGy with CESM. The dense breast phantom had a mean AGD of 1.3 mGy with 2D FFDM, 1.4 mGy with 3D tomosynthesis, and 2.1 mGy with CESM. At a compressed thickness of 4.5 cm, radiation exposure from CESM was approximately 25% higher in dense breast phantoms than in nondense breast phantoms. The dose in the dense phantom at a compressed thickness of 6 cm was approximately 42% higher than the dose in the nondense phantom at a compressed thickness of 4.5 cm. CESM was found to increase AGD at a mean breast thickness of 63 mm by approximately 0.9 mGy and 0.5 mGy compared with 2D FFDM and 3D tomosynthesis, respectively. Of note, CESM provides a standard image (similar to 2D FFDM) that is obtained using the low-energy projection. Overall, the AGD from CESM falls below the dose limit of 3 mGy set by Mammography Quality Standards Act regulations.

  16. Occupational external radiation exposure in the GDR in 1976

    International Nuclear Information System (INIS)

    Rothe, W.

    1980-01-01

    In 1976 a total of 36,794 occupationally exposed persons were monitored by the National Board of Nuclear Safety and Radiation Protection, using film badges. The monthly over-exposures (more than 4 mGy) totalled 415. In 11 cases the monthly exposure exceeded 30 mGy and 6 annual exposure values were in the range of 50 to 120 mGy. An attempt has been made to assess the annual collective and annual per caput doses for the exposed population as a whole and some subgroups without completely summing up the individual exposure data. (author)

  17. Evaluation of experimental animal biological state at exposure to low-dose ionizing radiation

    International Nuclear Information System (INIS)

    Rozanov, V.A.; Rejtarova, T.Je.; Chernyikov, G.B.; Timoshevs'ka, Je.V.; Kozozojeva, O.O.

    1997-01-01

    New approaches to quantitative evaluation of ionizing radiation absorbed dose within the low-dose range (up to 400 mGy) according to the degree of the organism biological response was developed. The purpose of the stage of the work published in Communication 1 is to evaluate the shifts in the animal behaviour and cellular composition of the blood at irradiation by the dose of 100,200 and 400 mGy. Distinct dose dependence of behaviour reactions and hematological indices within the dose range of 100-400 mGy was not noted

  18. Radiation dose in vertebroplasty

    International Nuclear Information System (INIS)

    Mehdizade, A.; Lovblad, K.O.; Wilhelm, K.E.; Somon, T.; Wetzel, S.G.; Kelekis, A.D.; Yilmaz, H.; Abdo, G.; Martin, J.B.; Viera, J.M.; Ruefenacht, D.A.

    2004-01-01

    We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements. (orig.)

  19. Radiation hormesis of radish using an X-ray photography device

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Atsushi [Asahikawa Kousei Hospital, Hokkaido (Japan)

    2000-07-01

    Radiation hormesis was studied at an X-ray photography room. Seed of radish (Kaiwaredaikon) was irradiated by X-ray, from 10 to 3000 mGy. Since the growth of plant was the highest around 500 mGy, 100 seeds were irradiated at a dose of 500 mGy. Fifty seeds were selected and the growth rate was measured after 1 and 2 weeks. After 2 weeks, the growth of the seeds irradiated (129{+-}5 mm) was found to be higher than those without irradiation (115{+-}5 mm). (author)

  20. Exploring the Digital Universe with Europe's Astrophysical Virtual Observatory

    Science.gov (United States)

    2001-12-01

    N° 73-2001 - Paris, 5 December 2001 The aim of AVO is to give astronomers instant access to the vast databanks now being built up by the world's observatories and forming what is in effect a "digital sky". Using AVO astronomers will be able, for example, to retrieve the elusive traces of the passage of an asteroid as it passes the Earth and so predict its future path and perhaps warn of a possible impact. When a giant star comes to the end of its life in a cataclysmic explosion called a supernova, they will be able to access the digital sky and pinpoint the star shortly before it exploded, adding invaluable data to the study of the evolution of stars. Modern observatories observe the sky continuously and data accumulates remorselessly in the digital archives. The growth rate is impressive and many hundreds of terabytes of data -corresponding to many thousands of billions of pixels - are already available to scientists. The real sky is being digitally reconstructed in the databanks. The volume and complexity of data and information available to astronomers are overwhelming. Hence the problem of how astronomers can possibly manage, distribute and analyse this great wealth of data. The Astrophysical Virtual Observatory will enable them to meet the challenge and "put the Universe online". AVO is a three-year project, funded by the European Commission under its Research and Technological Development (RTD) scheme, to design and implement a virtual observatory for the European astronomical community. The Commission has awarded a contract valued at EUR 4m for the project, starting on 15 November. AVO will provide software tools to enable astronomers to access the multi-wavelength data archives over the Internet and so give them the capability to resolve fundamental questions about the Universe by probing the digital sky. Equivalent searches of the "real" sky would, in comparison, both be prohibitively costly and take far too long. Towards a Global Virtual Observatory The

  1. Coronary cineangiography and ionizing radiation exposure to patients: analysis of primary and secondary beam

    International Nuclear Information System (INIS)

    Ramirez, Alfredo; Leyton, Fernando; Silva, Ana Maria; Farias, Eric

    2001-01-01

    The purpose of this work was to determine the level of exposure dose to patients during coronariographies in different areas of body. This study has presented the medical surveillance of 18 cases and the radiation monitoring of these patients by TLD in thyroid and pelvis (secondary beam) and, in the right and left scapular region (primary beam) for each one of these procedures. The ionizing radiation received was 215 ± 200 mGy in left scapular region (range 1-710) and 255±213 mGy in the right scapular region (range 22-635) p=NS. In the pelvic region the ionizing radiation was 0,22±0,06 mGy and in the thyroid region was 3,62±2,44 mGy

  2. Investigation of LiF, Mg and Ti (TLD-100 Reproducibility

    Directory of Open Access Journals (Sweden)

    Sadeghi M.

    2015-12-01

    Full Text Available LiF, Mg and Ti cubical TLD chips (known as TLD-100 are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC were obtained 4 times by irradiating them to doses of 81 mGy (two times, 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  3. Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.

    Science.gov (United States)

    Sadeghi, M; Sina, S; Faghihi, R

    2015-12-01

    LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  4. Dosimetry comparison of pelvimetry methods using conventional radiographs and CT

    International Nuclear Information System (INIS)

    Resten, A.; Suissa, M.; Musset, D.; Mausoleo, F.; Valero, M.; Taylor, S.

    2001-01-01

    To determine the fetal and maternal exposure to radiation by use of thermoluminescent dosimeters in order to compare conventional and CT-scan X-ray. Dosimetry was performed with an anthropomorph phantom. Thermoluminescent dosimeters were positioned on the surface and in the depth of the phantom. Digital radiography of the pelvis was performed according to a standard technique. CT-scan of the pelvis was performed according to the Buthiau's technique. With CT, the dose reached 0.31 to 4.95 mGy, with a dose of 2.32 mGy for the fetal gonads. With standard technique, the doses reached 0.03 to 0.39 mGy, with a dose of 0.39 mGy for the fetal gonads. With CT the fetus and the mother were exposed to 1/10. of the total dose delivered using conventional X-rays and the dose distribution was more homogeneous. (author)

  5. Evaluation of occupational and patient radiation doses in orthopedic surgery

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Habeeballa, B.; Osman, H.; Abdelaziz, I.; Sassi, S.A.; Sam, A.K.

    2015-01-01

    This study intends to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (DHS) and (ii) Dynamic Cannula Screw (DCS) and to evaluate entrance surface Air kerma (ESAK) dose and organ doses and effective doses. Calibrated Thermoluminescence dosimeters (TLD-GR200A) were used. The mean patients’ doses were 0.46 mGy and 0.07 mGy for DHS and DCS procedures, respectively. The mean staff doses at the thyroid and chest were 4.69 mGy and 1.21 mGy per procedure. The mean organ and effective dose for patients and staff were higher in DHS compared to DCS. Orthopedic surgeons were exposed to unnecessary radiation doses due to the lack of protection measures. The radiation dose per hip procedure is within the safety limit and less than the previous studies

  6. Maltese CT doses for commonly performed examinations demonstrate alignment with published DRLs across europe

    International Nuclear Information System (INIS)

    Zarb, F.; McEntee, M.; Rainford, L.

    2012-01-01

    This work recommends dose reference levels (DRLs) for abdomen, chest and head computerised tomography (CT) examinations in Malta as the first step towards national CT dose optimisation. Third quartiles volume CT dose index values for abdomen: 12.1 mGy, chest: 13.1 mGy and head: 41 mGy and third quartile dose-length product values for abdomen: 539.4, chest: 492 and head: 736 mGy cm -1 are recommended as Maltese DRLs derived from this first Maltese CT dose survey. These values compare well with DRLs of other European countries indicating that CT scanning in Malta is consistent with standards of good practice. Further work to minimise dose without affecting image quality and extending the establishment of DRLs for other CT examinations is recommended. (authors)

  7. Occupational radiation exposure in the GDR in 1980

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1982-01-01

    As in the previous year, the centralized monitoring of radiation workers for occupational exposure was carried out on the basis of film badges (38,781 persons), measurements with a whole-body counter and analyses of biosamples (351 persons in all). According to the film data, the monthly exposures exceeding 4 mGy totalled 682 including 48 doses higher than 10 mGy. Four workers received annual doses above 50 mGy, with the highest value being 1410 mGy. For the exposed population as a whole and some sub-groups, annual collective and mean annual doses have been given. In assessing internal exposure situation, use has been made of both data from the centralized monitoring program and those determined by some nuclear facilities themselves under the auspices of the SAAS. The results gave no indication of internal doses exceeding the annual limits of intake. (author)

  8. Occupational radiation exposure in the GDR in 1979

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1982-01-01

    As in the previous year, the centralized monitoring of radiation workers for occupational exposure was carried out on the basis of film badges (38,178 persons), measurements with a whole-body counter (247 persons) and analyses of biosamples (318 persons). According to the film data, the monthly exposures exceeding 4 mGy totalled 610 including 92 doses higher than 10 mGy. Six workers received annual doses above 50 mGy, with the highest value being 123 mGy. For the exposed population as a whole and some sub-groups, annual collective and mean annual doses have been given. In assessing the internal exposure situation, use has been made of both data from the centralized monitoring program and those determined by some nuclear facilities themselves under the auspices of the SAAS. The results gave no indication of internal doses exceeding the annual limits of intake. (author)

  9. Ultra-Fast All-Optical Self-Aware Protection Switching Based on a Bistable Laser Diode

    DEFF Research Database (Denmark)

    An, Yi; Vukovic, Dragana; Lorences Riesgo, Abel

    2014-01-01

    We propose a novel concept of all-optical protection switching with link failure automatic awareness based on AOWFF. The scheme is experimentally demonstrated using a single MG-Y laser diode with a record switching time ~200 ps....

  10. Evaluation of external and internal irradiation on uranium mining enterprise staff by tooth enamel EPR spectroscopy

    Science.gov (United States)

    Zhumadilov, Kassym; Ivannikov, Alexander; Khailov, Artem; Orlenko, Sergei; Skvortsov, Valeriy; Stepanenko, Valeriy; Kuterbekov, Kairat; Toyoda, Shin; Kazymbet, Polat; Hoshi, Masaharu

    2017-11-01

    In order to estimate radiation effects on uranium enterprise staff and population teeth samples were collected for EPR tooth enamel dosimetry from population of Stepnogorsk city and staff of uranium mining enterprise in Shantobe settlment (Akmola region, North of Kazakhstan). By measurements of tooth enamel EPR spectra, the total absorbed dose in the enamel samples and added doses after subtraction of the contribution of natural background radiation are determined. For the population of Stepnogorsk city average added dose value of 4 +/- 11 mGy with variation of 51 mGy was obtained. For the staff of uranium mining enterprise in Shantobe settlment average value of added dose 95 +/- 20 mGy, with 85 mGy variation was obtained. Higher doses and the average value and a large variation for the staff, probably is due to the contribution of occupational exposure.

  11. Coronary cineangiography and ionizing radiation exposure to patients: analysis of primary and secondary beam; Cineangiografia coronaria y radiacion ionizante a pacientes. Analisis en haz primario y secundario

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, Alfredo; Leyton, Fernando; Silva, Ana Maria; Farias, Eric [Universidad de Chile, Santiago (Chile). Hospital Clinico; Gamarra, Jorge; Oyarzun, Carlos [Comision Chilena de Energia Nuclear (CCHEN), Santiago (Chile)

    2001-07-01

    The purpose of this work was to determine the level of exposure dose to patients during coronariographies in different areas of body. This study has presented the medical surveillance of 18 cases and the radiation monitoring of these patients by TLD in thyroid and pelvis (secondary beam) and, in the right and left scapular region (primary beam) for each one of these procedures. The ionizing radiation received was 215 {+-} 200 mGy in left scapular region (range 1-710) and 255{+-}213 mGy in the right scapular region (range 22-635) p=NS. In the pelvic region the ionizing radiation was 0,22{+-}0,06 mGy and in the thyroid region was 3,62{+-}2,44 mGy.

  12. Patient and staff dose during hysterosalpinography

    International Nuclear Information System (INIS)

    Buls, N.; Osteaux, M.

    2001-01-01

    Hysterosalpingography (HSG) is a useful and widely employed technique which uses X-ray fluoroscopy to investigate the female genital tract. Fluoroscopy is assessed by a gynaecologist, a physician who is not always trained to work with ionising radiation. Dose-area product measurements in a group of 34 patients allowed an estimation of the median effective dose (0,83 mSv) and the median dose to the ovaries (1,63 mGy) of the patient per procedure. The dose to the staff was estimated using thermoluminescent dosimetry. The following median entrance surface doses were estimated per procedure: 0,22 mGy to the lens of the eye, 0,15 mGy to the neck at thyroid level and 0,19 mGy to the back of the hand. The annual eye dose limit could be exceeded if the gynaecologist is a member of the public. (author)

  13. Survey of image quality and patient dose in simple radiographic examinations: establishing guidance levels and comparison with international standards

    International Nuclear Information System (INIS)

    Manatrakul, N.; Bunsoong, T.; Krisanachinda, A.; Suwanpradit, P.; Rungruengthanakit, P.; Kanchart, S.; Chaiwong, Rajikorn; Tsapakig, V.A.

    2008-01-01

    Purpose: To investigate image quality and patient dose for commonly radiographic examinations in Thailand, to establish national reference or guidance levels (GL) and compare with international standards, as part of an International Atomic Energy Agency (IAEA) project on Radiation Protection of Patients and Medical Exposure Control (RAS/9/034 and RAS/9/047). Materials and Methods: Film reject rate analysis, image quality and patient dose assessment before and after Quality Control (QC) implementation were investigated in 8 X-ray machines in 4 hospitals. Air kerma (in mGy) at 1 meter focus-detector-distance for different kVp settings for each X-ray machines were measured using an ionization chamber under standardized condition. The entrance skin air kerma (ESAK) for Chest PA, Lumbar spine AP, Lumbar spine LAT, Pelvis AP, Abdomen AP, Skull AP and Skull LAT were calculated for at least 10 adult patients of average body mass (60 to 80 kg) for each projection. The obtained values were compared with international standards. Results: The highest film rejection rate reduction recorded after corrective actions from 9.15% to 6.8%. Mean ESAK values were less than international standards both before and after QC implementation in all projections but Chest PA projection. Maximum ESAK in Chest PA projection before corrective action was 0.55 mGy which was higher than the IAEA GL of 0.2 mGy. However, it was reduced to 0.25 mGy after QC tests on X- ray machine and using high kilovoltage (kV) technique. Conclusion: Proposed national GL of Thailand were obtained by estimating the 3rd quartile of the whole sample: Chest PA: 0.1 mGy, Lumbar Spine AP: 2.1 mGy, Lumbar Spine LAT: 6.3 mGy, Pelvis AP: 1.8 mGy, Abdomen: 1.5 mGy, Skull PA: 1.3 mGy and Skull LAT: 0.9 mGy. (author)

  14. Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

    Science.gov (United States)

    Chang, Lienard A; Miller, Donald L; Lee, Choonsik; Melo, Dunstana R; Villoing, Daphnée; Drozdovitch, Vladimir; Thierry-Chef, Isabelle; Winters, Sarah J; Labrake, Michael; Myers, Charles F; Lim, Hyeyeun; Kitahara, Cari M; Linet, Martha S; Simon, Steven L

    2017-12-01

    This study summarizes and compares estimates of radiation absorbed dose to the thyroid gland for typical patients who underwent diagnostic radiology examinations in the years from 1930 to 2010. The authors estimated the thyroid dose for common examinations, including radiography, mammography, dental radiography, fluoroscopy, nuclear medicine, and computed tomography (CT). For the most part, a clear downward trend in thyroid dose over time for each procedure was observed. Historically, the highest thyroid doses came from the nuclear medicine thyroid scans in the 1960s (630 mGy), full-mouth series dental radiography (390 mGy) in the early years of the use of x rays in dentistry (1930s), and the barium swallow (esophagram) fluoroscopic exam also in the 1930s (140 mGy). Thyroid uptake nuclear medicine examinations and pancreatic scans also gave relatively high doses to the thyroid (64 mGy and 21 mGy, respectively, in the 1960s). In the 21st century, the highest thyroid doses still result from nuclear medicine thyroid scans (130 mGy), but high thyroid doses are also associated with chest/abdomen/pelvis CT scans (18 and 19 mGy for males and females, respectively). Thyroid doses from CT scans did not exhibit the same downward trend as observed for other examinations. The largest thyroid doses from conventional radiography came from cervical spine and skull examinations. Thyroid doses from mammography (which began in the 1960s) were generally a fraction of 1 mGy. The highest average doses to the thyroid from mammography were about 0.42 mGy, with modestly larger doses associated with imaging of breasts with large compressed thicknesses. Thyroid doses from dental radiographic procedures have decreased markedly throughout the decades, from an average of 390 mGy for a full-mouth series in the 1930s to an average of 0.31 mGy today. Upper GI series fluoroscopy examinations resulted in up to two orders of magnitude lower thyroid doses than the barium swallow. There are

  15. DNA alterations and effects on growth and reproduction in Daphnia magna during chronic exposure to gamma radiation over three successive generations

    International Nuclear Information System (INIS)

    Parisot, Florian; Bourdineaud, Jean-Paul; Plaire, Delphine; Adam-Guillermin, Christelle; Alonzo, Frédéric

    2015-01-01

    Highlights: • We exposed three successive generations of Daphnia magna to chronic gamma radiation. • We examined DNA alterations and effects on survival, growth and reproduction. • DNA alterations were accumulated over a generation and transmitted to the progeny. • Effects on survival and reproduction, and delay in growth increased over generations. - Abstract: This study examined chronic effects of external Cs-137 gamma radiation on Daphnia magna exposed over three successive generations (F0, F1 and F2) to environmentally relevant dose rates (ranging from 0.007 to 35.4 mGy h −1 ). Investigated endpoints included survival, growth, reproduction and DNA alterations quantified using random-amplified polymorphic DNA polymerase chain reaction (RAPD-PCR). Results demonstrated that radiation effects on survival, growth and reproduction increased in severity from generation F0 to generation F2. Mortality after 21 days at 35.4 mGy h −1 increased from 20% in F0 to 30% in F2. Growth was affected by a slight reduction in maximum length at 35.4 mGy h −1 in F0 and by reductions of 5 and 13% in growth rate, respectively, at 4.70 and 35.4 mGy h −1 in F2. Reproduction was affected by a reduction of 19% in 21 day-fecundity at 35.4 mGy h −1 in F0 and by a delay of 1.9 days in brood release as low as 0.070 mGy h −1 in F2. In parallel, DNA alterations became significant at decreasing dose rates over the course of F0 (from 4.70 mGy h −1 at hatching to 0.007 mGy h −1 after ∼21 days) and from F0 to F2 (0.070 mGy h −1 at hatching to 0.007 mGy h −1 after ∼21 days), demonstrating their rapid accumulation in F0 daphnids and their transmission to offspring generations. Transiently more efficient DNA repair leading to some recovery at the organism level was suggested in F1, with no effect on survival, a slight reduction of 12% in 21 day-fecundity at 35.4 mGy h −1 and DNA alterations significant at highest dose rates only. The study improved our understanding of

  16. Evaluation of average glandular dose in mammography services in 10 cities of Colombia; Avaliacao de dose glandular media em servicos de mamografia de 10 cidades de Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Alejo-Martinez, H.; Salazar-Hurtado, E.; Puerto-Jimenez, D. [Grupo de Prevencion Temprana Del Cancer, Instituto Nacional de Cancerologia, Bogota D.C. (Colombia)

    2016-07-01

    The objective of this study was to conduct an assessment of dose in 60 mammography services that have screening programs for breast cancer in 10 cities of Colombia. The third quartile of the average glandular dose was 2,29 mGy, range between 1,0 and 5,6 mGy, for the phantom equivalent to a standard breast. This study included mammography units with conventional and digital technology. (author)

  17. Evaluation of average glandular dose in mammography services in 10 cities of Colombia

    International Nuclear Information System (INIS)

    Alejo-Martinez, H.; Salazar-Hurtado, E.; Puerto-Jimenez, D.

    2016-01-01

    The objective of this study was to conduct an assessment of dose in 60 mammography services that have screening programs for breast cancer in 10 cities of Colombia. The third quartile of the average glandular dose was 2,29 mGy, range between 1,0 and 5,6 mGy, for the phantom equivalent to a standard breast. This study included mammography units with conventional and digital technology. (author)

  18. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  19. Patient exposures in Swedish diagnostic radiology

    International Nuclear Information System (INIS)

    Bengtsson, G.; Blomgren, P.-G.; Bergman, K.; Aaberg, L.

    1977-01-01

    Variations in doses between individuals and hospitals are discussed. Mean values and collective doses for Sweden are estimated. The mean annual collective dose per individual was estimated as follows: thyroid 0.75 mGy; mammae 0.54 mGy; lungs 0.64 mGy; bone marrow 0.92 mGy; ovaries 0.68 mGy and testes 0.65 mGy. The genetically significant dose was estimated as 0.7 mGy, a doubling since 1955. The annual mean whole body dose calculated from the energy imparted was 1.00 mGy. These figures should be subject to errors of about a factor of 2, mainly originating from the poor sampling technique. Some simplified risk estimates relating to the various examinations are made using the mean organ doses. These estimates indicated that within a factor of 3 up or down, the overall cancer risk might be 10 -4 J -1 , that is, an imparted energy of 10 000 J would lead to one radiation induced cancer. The estimate would apply to all examinations except those on extremities. The estimate of radiation induced cancer, uncertain as it may be, totals 8 cases per million Swedes per year, which is small compared with the natural cancer incidence of about 2000 per million and year. No corresponding simplification using energy absorbed seemed possible concerning the genetic risks. The study shows that using available examination techniques a dose reduction by a factor of 2 or more should be po

  20. Phototransfered thermoluminescence for dose reassessment in LiF:mg,ti , LiF: mg,Cu,p TL detectors

    International Nuclear Information System (INIS)

    Rodriguez Otazo, M.; Baly, L.

    2001-01-01

    Phototransfered Thermoluminescence (PTTL) from LiF:Mg,Ti (TLD-100) and LiF: Mg,Cu,P (GR-200) was studied at different conditions using different sources of UV light for dose reassessment purposes. The TL dosimeters were irradiated with 137Cs in the range 2 mGy to 100 mGy. The convenience of using PTTL for dose reassessment was analyzed

  1. Bridging the Gap: Linking Simulation and Testing

    Energy Technology Data Exchange (ETDEWEB)

    Krajewski, Paul E.; Carsley, John; Stoudt, Mark R.; Hovanski, Yuri

    2012-09-01

    The Materials Genome Initiative (MGI) which is a key enabler for the Advanced Manufacturing Partnership, announced in 2011 by U.S. President Barack Obama, was established to accelerate the development and deployment of advanced materials. The MGI is driven by the need to "bridge the gap" between (I) experimental results and computational analysis to enable the rapid development and validation of new mateirals, and (II) the processes required to convert these materials into useable goods.

  2. Emergency CT head and neck imaging: effects of swimmer's position on dose and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Mueck, Fabian G.; Roesch, Sebastian; Geyer, Lucas; Scherr, Michael; Seidenbusch, Michael; Stahl, Robert; Deak, Zsuzsanna; Wirth, Stefan [LMU Klinikum Universitaet Muenchen (Germany). Inst. fuer Klinische Radiologie

    2014-05-15

    To compare the effects of different arm positions on dose exposure and image quality (IQ) in cervical spine CT after trauma in different patient groups. Patients in standard (STD = 126) and in swimmer's position (SWIM = 254) were included. Body mass index (BMI subgroup 1 = underweight to subgroup 4 = obese), anterior-posterior diameter (AP), left-right diameter (LR), area of an ellipse (AoE) and angle between the humeral heads (optimal STD < 3 , optimal SWIM > 10 ) were used as grouping criteria. Computed tomography dose index (CTDI) was documented. Two radiologists rated the IQ at three levels (CV1/2, CV4/5, CV7/T1) using a semi-quantitative scale (0 = not diagnostic, 1 = diagnostic with limitations, 2 = diagnostic without limitations). The Mann-Whitney U test correlations of grouping criteria with dose effects and intra-class correlation (ICC) were calculated. ICC was 0.87. BMI grouping showed the strongest correlation with dose effects: CTDI of optimal STD versus optimal SWIM positioning was 3.17 mGy versus 2.46 mGy (subgroup 1), 5.47 mGy versus 3.97 mGy (subgroup 2), 7.35 mGy versus 5.96 mGy (subgroup 3) and 8.71 mGy versus 8.18 mGy (subgroup 4). Mean IQ at CV7/T1 was 1.65 versus 1.23 (subgroup 1), 1.27 versus 1.46 (subgroup 2), 1.06 versus 1.46 (subgroup 3), 0.79 versus 1.5 (subgroup 4). Patients with a BMI > 20 kg/m{sup 2} benefited from both potential dose reduction and improved image quality at the critical cervicothoracic junction when swimmer's position was used. (orig.)

  3. Standardised approach to optimisation

    International Nuclear Information System (INIS)

    Warren-Forward, Helen M.; Beckhaus, Ronald

    2004-01-01

    Optimisation of radiographic images is said to have been obtained if the patient has achieved an acceptable level of dose and the image is of diagnostic value. In the near future, it will probably be recommended that radiographers measure patient doses and compare them to reference levels. The aim of this paper is to describe a standardised approach to optimisation of radiographic examinations in a diagnostic imaging department. A three-step approach is outlined with specific examples for some common examinations (chest, abdomen, pelvis and lumbar spine series). Step One: Patient doses are calculated. Step Two: Doses are compared to existing reference levels and the technique used compared to image quality criteria. Step Three: Appropriate action is taken if doses are above the reference level. Results: Average entrance surface doses for two rooms were as follows AP Abdomen (6.3mGy and 3.4mGy); AP Lumbar Spine (6.4mGy and 4.1mGy) for AP Pelvis (4.8mGy and 2.6mGy) and PA chest (0.19mGy and 0.20mGy). Comparison with the Commission of the European Communities (CEC) recommended techniques identified large differences in the applied potential. The kVp values in this study were significantly lower (by up to lOkVp) than the CEC recommendations. The results of this study have indicated that there is a need to monitor radiation doses received by patients undergoing diagnostic radiography examinations. Not only has the assessment allowed valuable comparison with International Diagnostic Reference Levels and Radiography Good Practice but has demonstrated large variations in mean doses being delivered from different rooms of the same radiology department. Following the simple 3-step approach advocated in this paper should either provide evidence that department are practising the ALARA principle or assist in making suitable changes to current practice. Copyright (2004) Australian Institute of Radiography

  4. Atrazine is primarily responsible for the toxicity of long-term exposure to a combination of atrazine and inorganic arsenic in the nigrostriatal system of the albino rat.

    Science.gov (United States)

    Bardullas, Ulises; Giordano, Magda; Rodríguez, Verónica Mireya

    2013-01-01

    Chronic and simultaneous exposure to a variety of chemicals present in the environment is an unavoidable fact. However, given the complexity of studying chemical mixtures, most toxicological studies have focused on the effects of short-term exposure to single substances. The aim of this study was to evaluate the effects on the nigrostriatal system of the chronic, simultaneous exposure to two widely distributed substances that have been identified as potential dopaminergic system toxicants, inorganic arsenic (iAs) and atrazine (ATR). Six groups of rats were treated daily for one year with atrazine (10mg ATR/kg), inorganic arsenic (0.5 or 50mgiAs/L of drinking water), or a combination of ATR+0.5mgiAs/L or ATR+50mgiAs/L. The 50mgiAs/L group showed locomotor hypoactivity, while all treatments decreased motor coordination in contrast no effects of treatment were found on the place and response learning tasks. Regarding markers for liver and muscle damage, there were no differences between groups in creatine kinase (CK) or aspartate transaminase (AST) activities, while decreases in lactate dehydrogenase (LDH) levels were found in some exposed groups. The striatal DA content was significantly reduced in ATR, 0.5mgiAs/L, ATR+0.5mgiAs/L, and ATR+50mgiAs/L groups, in comparison to the control group. The number of mesencephalic tyrosine hydroxylase positive cells decreased in the ATR and ATR+0.5mgiAs/L groups compared to the control. In contrast, immunoreactivity to cytochrome oxidase was reduced compared to the control in all treated groups, except for the group treated with 0.5iAsmg alone. Our results indicate that ATR has deleterious effects on dopaminergic neurons and that the combination of ATR and iAs does not exacerbate these effects. © 2013 Elsevier Inc. All rights reserved.

  5. A novel dendrimer based on poly (L-glutamic acid) derivatives as an efficient and biocompatible gene delivery vector

    International Nuclear Information System (INIS)

    Zeng Xin; Pan Shirong; Wang Chi; Wen Yuting; Wu Hongmei; Wang Cuifeng; Wu Chuanbin; Feng Min; Li Jie

    2011-01-01

    Non-viral gene delivery systems based on cationic polymers have faced limitations related to their relative low gene transfer efficiency, cytotoxicity and system instability in vivo. In this paper, a flexible and pompon-like dendrimer composed of poly (amidoamine) (PAMAM) G4.0 as the inner core and poly (L-glutamic acid) grafted low-molecular-weight polyethylenimine (PLGE) as the surrounding multiple arms was synthesized (MGI dendrimer). The novel MGI dendrimer was designed to combine the merits of size-controlled PAMAM G4.0 and the low toxicity and flexible chains of PLGE. In phosphate-buffered saline dispersions the well-defined DNA/MGI complex above a N/P ratio of 30 showed good stability with particle sizes of approximately 200 nm and a comparatively low polydispersity index. However, the particle size of the DNA/25 kDa polyethylenimine (DNA/PEI 25K) complex was larger than 700 nm under the same salt conditions. The shielding of the compact amino groups at the periphery of flexible PAMAM and biocompatible PLGE chains in MGI resulted in a dramatic decrease of the cytotoxicity compared to native PAMAM G4.0 dendrimer. The in vitro transfection efficiency of DNA/MGI dendrimer complex was higher than that of PAMAM G4.0 dendrimer. Importantly, in serum-containing medium, DNA/MGI complexes at their optimal N/P ratio maintained the same high levels of transfection efficiency as in serum-free medium, while the transfection efficiency of native PAMAM G4.0, PEI 25K and Lipofectamine 2000 were sharply decreased. In vivo gene delivery of pVEGF165/MGI complex into balloon-injured rabbit carotid arteries resulted in significant inhibition of restenosis by increasing VEGF165 expression in local vessels. Therefore, the pompon-like MGI dendrimer may be a promising vector candidate for efficient gene delivery in vivo.

  6. Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE)

    Energy Technology Data Exchange (ETDEWEB)

    Kidoh, Masafumi; Utsunomiya, Daisuke; Oda, Seitaro; Nakaura, Takeshi; Yuki, Hideaki; Hirata, Kenichiro; Namimoto, Tomohiro; Sakabe, Daisuke; Hatemura, Masahiro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Honjo, Kumamoto (Japan); Funama, Yoshinori [Kumamoto University, Department of Medical Physics, Faculty of Life Sciences, Honjo, Kumamoto (Japan)

    2017-06-15

    To investigate the usefulness of modifying scanning parameters based on the size-specific dose estimate (SSDE) for a breast-dose reduction for chest CT. We scanned 26 women with a fixed volume CT dose index (CTDI{sub vol}) (15 mGy) and another 26 with a fixed SSDE (15 mGy) protocol (protocol 1 and 2, respectively). In protocol 2, tube current was calculated based on the patient habitus obtained on scout images. We compared the mean breast dose and the inter-patient breast dose variability and performed linear regression analysis of the breast dose and the body mass index (BMI) of the two protocols. The mean breast dose was about 35 % lower under protocol 2 than protocol 1 (10.9 mGy vs. 16.8 mGy, p < 0.01). The inter-patient breast dose variability was significantly lower under protocol 2 than 1 (1.2 mGy vs. 2.5 mGy, p < 0.01). We observed a moderate negative correlation between the breast dose and the BMI under protocol 1 (r = 0.43, p < 0.01); there was no significant correlation (r = 0.06, p = 0.35) under protocol 2. The SSDE-based protocol achieved a reduction in breast dose and in inter-patient breast dose variability. (orig.)

  7. Histological variations in liver of freshwater fish Oreochromis mossambicus exposed to 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Sadiq Bukhari, A.; Syed Mohamed, H.E.; Broos, K.V.; Stalin, A.; Singhal, R.K.; Venubabu, P.

    2012-01-01

    The irradiation effect of 60 Co at the three dose level of 3 mGy, 30 mGy and 300 mGy on the histology of liver of the freshwater fish Oreochromis mossambicus was investigated. The liver of O. mossambicus was dissected out and processed for light microscopy studies. 60 Co exposed O. mossambicus were found to result in several alterations in the histoarchitecture of liver. The alterations included mild congestion of blood vessels, structural alteration, cellular swelling, vacuolation and necrotic liver cells, indicating a definite response to 60 Co irradiation. The results suggest that the liver of O. mossambicus exposed to 60 Co were structurally altered with increasing dose levels. It is to record that alteration in the liver does not affect the physiology, behaviour or lethality of the individuals. Self regulating mechanisms would have influenced the liver to remain sustained. To confirm the same further studies in the direction by increasing dose level is required. - Highlights: ► Fish Oreochromis mossambicus irradiated to the dose of 3 mGy, 30 mGy and 300 mGy. ► Histoarchitecture of liver altered with increasing dose levels of 60 Co. ► Alteration in the liver does not affect the physiology, behaviour or lethality. ► Self regulating mechanisms might have prevented from Lethality. ► HSI index value for exposed group reported ( 60 Co.

  8. Entrance radiation doses during paediatric cardiac catheterizations performed for diagnosis or the treatment of congenital heart disease

    International Nuclear Information System (INIS)

    Papadopoulou, D.; Yakoumakis, Em; Sandilos, P.; Thanopoulos, V.; Makri, Tr; Gialousis, G.; Houndas, D.; Yakoumakis, N.; Georgiou, Ev

    2005-01-01

    The purpose of this study was to estimate the radiation exposure of children, during cardiac catheterizations for the diagnosis or treatment of congenital heart disease. Radiation doses were estimated for 45 children aged from 1 d to 13 y old. Thermoluminescent dosemeters (TLDs) were used to estimate the posterior entrance dose (D P ), the lateral entrance dose (D LAT ), the thyroid dose and the gonads dose. A dose-area product (DAP) meter was also attached externally to the tube of the angiographic system and gave a direct value in mGy cm 2 for each procedure. Posterior and lateral entrance dose values during cardiac catheterizations ranged from 1 to 197 mGy and from 1.1 to 250.3 mGy, respectively. Radiation exposure to the thyroid and the gonads ranged from 0.3 to 8.4 mGy to 0.1 and 0.7 mGy, respectively. Finally, the DAP meter values ranged between 360 and 33,200 mGy cm 2 . Radiation doses measured in this study are comparable with those reported to previous studies. Moreover, strong correlation was found between the DAP values and the entrance radiation dose measured with TLDs. (authors)

  9. Radiation exposure of contrast-enhanced spectral mammography compared with full-field digital mammography.

    Science.gov (United States)

    Jeukens, Cécile R L P N; Lalji, Ulrich C; Meijer, Eduard; Bakija, Betina; Theunissen, Robin; Wildberger, Joachim E; Lobbes, Marc B I

    2014-10-01

    Contrast-enhanced spectral mammography (CESM) shows promising initial results but comes at the cost of increased dose as compared with full-field digital mammography (FFDM). We aimed to quantitatively assess the dose increase of CESM in comparison with FFDM. Radiation exposure-related data (such as kilovoltage, compressed breast thickness, glandularity, entrance skin air kerma (ESAK), and average glandular dose (AGD) were retrieved for 47 CESM and 715 FFDM patients. All examinations were performed on 1 mammography unit. Radiation dose values reported by the unit were validated by phantom measurements. Descriptive statistics of the patient data were generated using a statistical software package. Dose values reported by the mammography unit were in good qualitative agreement with those of phantom measurements. Mean ESAK was 10.5 mGy for a CESM exposure and 7.46 mGy for an FFDM exposure. Mean AGD for a CESM exposure was 2.80 mGy and 1.55 mGy for an FFDM exposure. Compared with our institutional FFDM, the AGD of a single CESM exposure is increased by 1.25 mGy (+81%), whereas ESAK is increased by 3.07 mGy (+41%). Dose values of both techniques meet the recommendations for maximum dose in mammography.

  10. Results of tooth enamel EPR dosimetry for population living in the vicinity of the Semipalatinsk nuclear test site

    Energy Technology Data Exchange (ETDEWEB)

    Zhumadilov, K. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan)], E-mail: kassym@hiroshima-u.ac.jp; Ivannikov, A. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan); Medical Radiological Research Center, Obninsk, 249036 (Russian Federation); Apsalikov, K. [Scientific-Research Institute for Radiation Medicine and Ecology, Semipalatinsk 490050 (Kazakhstan); Zhumadilov, Zh. [Semipalatinsk State Medical Academy, Semipalatinsk 490050 (Kazakhstan); Zharlyganova, D. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan); Stepanenko, V.; Skvortsov, V. [Medical Radiological Research Center, Obninsk, 249036 (Russian Federation); Berekenova, G. [Scientific-Research Institute for Radiation Medicine and Ecology, Semipalatinsk 490050 (Kazakhstan); Toyoda, S. [Department of Applied Physics Faculty of Science Okayama University of Science, 700-0005 (Japan); Endo, S.; Tanaka, K. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan); Miyazawa, C. [School of Dentistry, Ohu University, Koriyama-shi, Fukushima Pref. 963-8611 (Japan); Hoshi, M. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 734-8553 (Japan)

    2007-07-15

    The method of electron paramagnetic resonance (EPR) dosimetry was used on human tooth enamel to obtain individual absorbed doses of residents of settlements in the vicinity of the Nuclear Test Site (SNTS) in Semipalatinsk region, Kazakhstan. Measured teeth were extracted according to medical indications. In total, 105 tooth enamel samples were analyzed, including eight tooth samples from control settlement Kokpekty, which is located 400 km to the Southeast from SNTS and was not subjected to any radioactive contamination. It was found that the excess doses obtained after subtraction of the contribution of natural background radiation ranged up to about 440 mGy for residents of Dolon, whose tooth enamel was formed before 1949, and do not exceed 100 mGy for younger residents. For residents of Mostik, excess doses do not exceed 100 mGy for all ages except in one resident, for whom an extremely high dose of 1250 mGy was registered. For Bodene settlement, excess doses higher than 100 mGy were obtained for two samples from the residents having enamel formed before 1949. An extremely high dose (2800{+-}400 mGy) was obtained for one resident of Semipalatinsk City. The average excess dose for Semipalatinsk samples with enamel formation before 1949 was determined close to the average excess dose for tooth enamel samples from Dolon village.

  11. Investigating the embryo/larval toxic and genotoxic effects of {gamma} irradiation on zebrafish eggs

    Energy Technology Data Exchange (ETDEWEB)

    Simon, O., E-mail: olivier.simon@irsn.fr [Laboratoire de Radioecologie et d' Ecotoxicologie, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 186, BP3, 13115 Saint-Paul-lez-Durance Cedex (France); Massarin, S. [Laboratoire de Modelisation Environnementale, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 159, BP3, 13115 Saint-Paul-lez-Durance Cedex (France); Coppin, F. [Laboratoire de Radioecologie et d' Ecotoxicologie, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 186, BP3, 13115 Saint-Paul-lez-Durance Cedex (France); Hinton, T.G. [Service d' Etude du Comportement des Radionucleides dans les Ecosystemes, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 159, BP3, 13115 Saint-Paul-lez-Durance Cedex (France); Gilbin, R. [Laboratoire de Radioecologie et d' Ecotoxicologie, Institut de Radioprotection et de Surete Nucleaire, Cadarache, Bat 186, BP3, 13115 Saint-Paul-lez-Durance Cedex (France)

    2011-11-15

    Eggs/larval of freshwater fish (Danio rerio) were exposed to low dose rates of external gamma radiation (from 1 to 1000 mGy d{sup -1}) over a 20-day period, with the objective of testing the appropriateness of the 10 mGy d{sup -1} guideline suggested by the IAEA. The present study examines different endpoints, mortality and hatching time and success of embryos as well as the genotoxicity of {gamma}-irradiations (after 48 h). The 20-day embryo-larval bioassay showed an enhanced larval resistance to starvation after chronic exposure to {gamma} irradiation (from low 1 mGy d{sup -1} to high dose rate 1000 mGy d{sup -1}) and an acceleration in hatching time. Gamma irradiation led to increased genotoxic damage Ito zebrafish egg (40-50% DNA in tail in Comet assay) from the lowest dose rate (1 mGy d{sup -1}). Possible mechanisms of {gamma} radiotoxicity and implications for radioprotection are discussed. - Highlights: > Relevant information on the {gamma} radiation impact on early life stage biota is scarce. > The eggs of zebrafish Danio rerio were selected as biological model. > We test the appropriateness of the 10 mGy d{sup -1} guideline (IAEA). > We observed effects measured at individual levels (starvation, hatching time). > Chronic gamma irradiation led to increased genotoxic damage to zebrafish egg. > {gamma} radiotoxicity mechanisms and implications for radioprotection are discussed.

  12. Adaptive response of apoptosis in EL-4 lymphoma cells induced by low dose radiation and its mechanism

    International Nuclear Information System (INIS)

    Liu Shuchun; Gong Pingsheng; Wang Zhicheng; Sun Liguang; Gong Shouliang

    2008-01-01

    EL-4 lymphoma cells were irradiated with the inductive doses (D1: 25-200 mGy, dose rate: 12.5mGy/min) and the challenging dose (D2:0.5-3.0 Gy, dose rate: 287 mGy/min), and the time interval between D1 and D2 was 6 h. The percentage of cell apoptosis and the expressive levels of cell apoptosis-associated gene pro- reins were measured with flow cytometry. The percentages of cell apoptosis in the D1 + D2 group with 25-100 mGy (D1) and 1.5 Gy (D2) or 75 mGy (D1) and 25-200 mGy (D2) were significantly lower than those in the D2 group. As compared with the D2 group, the positive percentage of cell Bcl-2 protein expression increased somewhat, and Bax decreased significantly, meanwhile the ratio of Bcl-2/Bax increased significantly and p53 decreased somewhat in D1 + D2 group with 25-100 mGy (D1) and 1.5 Gy (D2). The adaptive response of EL-4 lymphoma cell apoptosis could be induced by pre-irradiation with 25-100 mGy. Meantime, the expressive levels of cell apoptosis-associated gene Bcl-2, Bax and p53 proteins could change accordingly with cell apoptosis. These gene protein changes may play an important role in the mechanism of the adaptive response. (authors)

  13. Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Yong; Lee, Byung Young; Lee, Jung Eun; Lee, Hyun Koo; Jung, Seunbg Hwan; Kim, Byung Woo; Kim, Hyeog Ju; Kim, Dong Sup [Radiation Safety Division National Institute of Food and Drug Safety Evaluation, Seoul (Korea, Republic of)

    2009-12-15

    entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  14. Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea

    International Nuclear Information System (INIS)

    Lee, Kwang Yong; Lee, Byung Young; Lee, Jung Eun; Lee, Hyun Koo; Jung, Seunbg Hwan; Kim, Byung Woo; Kim, Hyeog Ju; Kim, Dong Sup

    2009-01-01

    entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  15. Evaluation of an exposed-radiation dose on a dual-source cardiac computed tomography examination with a prospective electrocardiogram-gated fast dual spiral scan

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Koshida, Kichiro; Koshida, Haruka; Sakuta, Keita; Hayashi, Hiroyuki; Takata, Tadanori; Horii, Junsei; Kawai, Keiichi; Yamamoto, Tomoyuki

    2012-01-01

    We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.03 mGy for the breast, 9.96 mGy for the heart, 6.60 mGy for the lung, 6.48 mGy for the bone marrow, 9.73 mGy for the thymus, and 4.58 mGy for the skin. These values were about 5% of the absorbed doses for the retrospective ECG-gated dual spiral scan. However, the absorbed dose differed greatly at each scan, especially in the external organs such as the breast. For effective and safe use of the prospective ECG-gated fast dual spiral scan, it is necessary to understand these characteristics sufficiently. (author)

  16. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  17. Radiation pretreatments of cellulose materials for the enhancement of enzymatic hydrolysis

    International Nuclear Information System (INIS)

    Ait Si Mamar, S.; Hadjadj, A.

    1990-01-01

    The conversion of wheat straw agricultural cellulosic wastes to reducing sugars and glucose has been studied by pretreatments by acid hydrolysis and gamma radiolysis over the dose 0-2 MGy. The pretreatment of cellulosic wastes by gamma radiolysis in the presence of sulfuric acid solution shows that the reducing sugars yield increases with the irradiation dose. The effect of radiation degradation on cellulosic wastes between 0.1 MGy and 2 MGy shows the glucose and reducing sugars yields after enzymatic hydrolysis by cellulase vary with the dose. In the relatively low dose range, up to about 0.5 MGy, the reducing sugars yields vary slightly. For an acid hydrolysis followed by radiation at dose range below 0.5 MGy the reducing sugars yields are practically insensitive to radiation. On the other hand, the pretreatment by radiation in higher dose range from 0.5 to 2 MGy followed by enzymatic hydrolysis is effective for the conversion of cellulosic wastes into glucose. The radiation induced degradation of cellulose into glucose depends on the type of acid hydrolysis and on the enzymatic hydrolysis time by cellulase. Pre-irradiation in air is more effective than in acid solution. (author)

  18. Radiation pretreatments of cellulose materials for the enhancement of enzymatic hydrolysis

    Science.gov (United States)

    Mamar, S. Ait Si; Hadjadj, A.

    The conversion of wheat straw agricultural cellulosic wastes to reduning sugars and glucose has been studied by pretreatments by acid hydrolysis and gamma radiolysis over the dose 0-2 MGy. The pretreatment of cellulosic wastes by gamma radiolysis in the presence of sulfuric acid solution shows that the reducing sugars yield increases with the irradiation dose. The effect of radiation degradation on cellulosic wastes between 0.1 MGy and 2 MGy shows the glucose and reducing sugars yields after enzymatic hydrolysis by cellulase vary with the dose. In the relatively low dose range, up to about 0.5 MGy, the reducing sugars yields vary slightly. For an acid hydrolysis followed by radiation at dose range below 0.5 MGy the reducing sugars yields are practically insensitive to radiation. On the other hand, the pretreatment by radiation in higher dose range from 0.5 to 2 MGy followed by enzymatic hydrolysis is effective for the conversion of cellulosic wastes into glucose. The radiation induced degradation of cellulose into glucose depends on the type of acid hydrolysis and on the enzymatic hydrolysis time by cellulase. Pre-irradiation in air is more effective than in acid solution.

  19. Radiation and mental retardation

    International Nuclear Information System (INIS)

    Pochin, E.E.

    1988-01-01

    The editorial comments on a report published by the Radiation Effects Research Foundation in Hiroshima updating information on the induction of mental changes in the light of the revised and more detailed estimate of doses of radiation during pregnancies received by those exposed at Hiroshima and Nagasaki. The estimated risks are little changed. The likelihood of a threshold for exposure during the 16th to 25th week is confirmed-at 700 mGy (with a lower 95% confidence interval of 200 mGy). For the more sensitive time between the eighth to 15th weeks a linear model with no threshold still gives a statistically adequate fit to the data. Now, however, if linear models are tested without the constraint of postulating a threshold of zero, fits are obtained indicating substantial thresholds below which mental retardation would not result. When data on all children are included the maximum likelihood threshold value averages about 250 mGy on the different criteria tested (with mean 95% confidence intervals of 0 and 550 mGy). Or if the analyses exclude five children with conditions that themselves sometimes cause mental retardation a threshold of about 400 mGy is indicated (with mean 95% confidence intervals of 150 and 600 mGy). (author)

  20. Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.

    Science.gov (United States)

    Cornfeld, Daniel; Israel, Gary; Detroy, Ezra; Bokhari, Jamal; Mojibian, Hamid

    2011-03-01

    The purpose of the study was to quantify the radiation dose reduction achieved when imaging the aorta using Adaptive Statistical Iterative Reconstruction (ASIR) and to determine if this has an effect on image quality. We retrospectively reviewed 31 CT angiography examinations of the thoracic and abdominal aorta performed with ASIR and 32 consecutive similar examinations performed without ASIR. Volume CT dose index (CTDI(vol)), dose-length product (DLP), aortic enhancement at multiple levels, aorta-to-muscle contrast-to-noise ratio at multiple levels, and subjective image quality were compared between the two groups. The mean CTDI(vol) and DLP were significantly lower for the studies performed with ASIR versus studies without ASIR (15.6 vs 21.5 mGy, with an average difference of 5.8 mGy [95% CI 2.3-9.4 mGy] and 818 vs 1075 mGy × cm with an average difference of -257 mGy × cm [54-460 mGy × cm], respectively). Aortic enhancement, aortic signal-to-noise ratio, and aortic to muscle contrast-to-noise ratio were not different between the two groups. Subjectively, one reviewer preferred the non-ASIR images and one found the images equivalent. Both reviewers believed the images were of diagnostic quality. A 29% decrease in CTDI(vol) and a 20% decrease in DLP were obtained in scans with ASIR compared with scans without ASIR, without a quantitative loss of image quality.

  1. National reference doses for dental cephalometric radiography.

    Science.gov (United States)

    Holroyd, J R

    2011-12-01

    Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

  2. Evaluation of pediatrics entrance surface air kerma during chest X-ray examinations in some Khartoum hospitals

    International Nuclear Information System (INIS)

    Mohamed, Hassan Ishag Yahya

    2015-10-01

    The aim of this study was to determine the amount of entrance surface air kerma dose in air that can reflect the amount of the risk that the children, are subjected to. The parameters that are involved in this project are x-ray tube current (mA), exposure time (sec.), and focal skin distance (FSD) in cm. ESAK is calculated using the equation: ESAK=(Output (mGy/mAs) x (100/FSD) 2 X mAs) for different examination of different patients. 65 cases were involved in this study, the results show that the ESAK mean value (0.18±0.07) mGy, (0.06±0.07) mGy, (0.045±0.017) mGy and (0.049±0.013) mGy at the hospitals (IBNIOF Omdurman, police, clinic doctor) respectively. IBNIOF presented the highest ESAK (0.18±0.07) mGy, while it was lowest in police (0.045±0.017) mGy. The estimated ESAK value were within the established international reference dose values and also the values obtained in pervious studies however, variations were observed in ESAK values among hospitals under study which could be due to the differences in exposure parameters used. Also tube output has some effect on obtained ESAK. (author)

  3. Effects of Chronic Low-Dose Radiation on Human Neural Progenitor Cells

    Science.gov (United States)

    Katsura, Mari; Cyou-Nakamine, Hiromasa; Zen, Qin; Zen, Yang; Nansai, Hiroko; Amagasa, Shota; Kanki, Yasuharu; Inoue, Tsuyoshi; Kaneki, Kiyomi; Taguchi, Akashi; Kobayashi, Mika; Kaji, Toshiyuki; Kodama, Tatsuhiko; Miyagawa, Kiyoshi; Wada, Youichiro; Akimitsu, Nobuyoshi; Sone, Hideko

    2016-01-01

    The effects of chronic low-dose radiation on human health have not been well established. Recent studies have revealed that neural progenitor cells are present not only in the fetal brain but also in the adult brain. Since immature cells are generally more radiosensitive, here we investigated the effects of chronic low-dose radiation on cultured human neural progenitor cells (hNPCs) derived from embryonic stem cells. Radiation at low doses of 31, 124 and 496 mGy per 72 h was administered to hNPCs. The effects were estimated by gene expression profiling with microarray analysis as well as morphological analysis. Gene expression was dose-dependently changed by radiation. By thirty-one mGy of radiation, inflammatory pathways involving interferon signaling and cell junctions were altered. DNA repair and cell adhesion molecules were affected by 124 mGy of radiation while DNA synthesis, apoptosis, metabolism, and neural differentiation were all affected by 496 mGy of radiation. These in vitro results suggest that 496 mGy radiation affects the development of neuronal progenitor cells while altered gene expression was observed at a radiation dose lower than 100 mGy. This study would contribute to the elucidation of the clinical and subclinical phenotypes of impaired neuronal development induced by chronic low-dose radiation.

  4. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRIBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    Energy Technology Data Exchange (ETDEWEB)

    Michael G. Waddell; William J. Domoracki; Tom J. Temples

    2001-12-01

    This annual technical progress report is for part of Task 4 (site evaluation), Task 5 (2D seismic design, acquisition, and processing), and Task 6 (2D seismic reflection, interpretation, and AVO analysis) on DOE contact number DE-AR26-98FT40369. The project had planned one additional deployment to another site other than Savannah River Site (SRS) or DOE Hanford Site. After the SUBCON midyear review in Albuquerque, NM, it was decided that two additional deployments would be performed. The first deployment is to test the feasibility of using non-invasive seismic reflection and AVO analysis as a monitoring tool to assist in determining the effectiveness of Dynamic Underground Stripping (DUS) in removal of DNAPL. The second deployment is to the Department of Defense (DOD) Charleston Naval Weapons Station Solid Waste Management Unit 12 (SWMU-12), Charleston, SC to further test the technique to detect high concentrations of DNAPL. The Charleston Naval Weapons Station SWMU-12 site was selected in consultation with National Energy Technology Laboratory (NETL) and DOD Naval Facilities Engineering Command Southern Division (NAVFAC) personnel. Based upon the review of existing data and due to the shallow target depth, the project team collected three Vertical Seismic Profiles (VSP) and an experimental P-wave seismic reflection line. After preliminary data analysis of the VSP data and the experimental reflection line data, it was decided to proceed with Task 5 and Task 6. Three high resolution P-wave reflection profiles were collected with two objectives; (1) design the reflection survey to image a target depth of 20 feet below land surface to assist in determining the geologic controls on the DNAPL plume geometry, and (2) apply AVO analysis to the seismic data to locate the zone of high concentration of DNAPL. Based upon the results of the data processing and interpretation of the seismic data, the project team was able to map the channel that is controlling the DNAPL plume

  5. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    International Nuclear Information System (INIS)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M

    2016-01-01

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  6. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    Energy Technology Data Exchange (ETDEWEB)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  7. Strong T-phases recorded in the Aleutian Arc following the April 20, 2006 Koryakia, Russia Mw=7.6 earthquake

    Science.gov (United States)

    Jacobs, K. M.; McNutt, S. R.; Reyes, C. G.; Deangelis, S.

    2006-12-01

    The April 20, 2006 Mw=7.6 earthquake that occurred in Koryakia, Russia, just North of Kamchatka, produced very clear T-phases on seismic stations in the Aleutian Islands of Alaska. The seismic stations are maintained by the Alaska Volcano Observatory (AVO) to monitor volcanoes. Strong T-phases were recorded by most of the AVO network. The well-distributed locations of the AVO stations along most of the arc, allow unusually clear observations of phase travel times and path effects. T-phases were recorded most clearly and with highest amplitudes in the central and western Aleutians. A sharp decline in amplitude is seen moving east across the arc as the path crosses the Alaskan continental shelf in the eastern Bering Sea. The partial destructive effects of the Bower's Ridge blocking part of the energy are evident at stations on several of the westernmost Aleutian volcanoes. In the central Aleutians several volcano networks recorded a strong secondary T-phase which we believe to be a reflection from the continental shelf edge or from somewhere else along the path. There are other possible interpretations to this signal, which are also being investigated. Using arrival times and distances of the T-phases we have calculated an average apparent velocity in the SOFAR channel of about 1550 m/s. This is slightly above the predicted speeds of 1400-1500 m/s for the Bering Sea. Investigations of the causes of the velocities variations as well as the secondary T-phases are ongoing and will likely yield new information about seismic and acoustic propagation in the Bering Sea.

  8. Appraisal of gas hydrate resources based on a P- and S-impedance reflectivity template: case study from the deep sea sediments in Iran

    International Nuclear Information System (INIS)

    Hosseini Shoar, Behnam; Javaherian, Abdolrahim; Farajkhah, Nasser Keshavarz; Seddigh Arabani, Mojtaba

    2013-01-01

    The occurrence of a bottom simulating reflector (BSR) in the 2D seismic data from Makran's accretionary prism reveals the presence of gas hydrate and free gas several hundred meters below the seafloor of Iran's deep sea. According to the global distribution of marine hydrates, they are widely present in deep sea sediments, where high operational costs and hazards cause a lack of well log information. Therefore, developing a method to quantify the hydrate resources with seismic data is an ultimate goal for unexplored regions. In this study, the so-called reflectivity templates (RTs) are introduced for quantification of the hydrate and free gas near the BSR. These RTs are intuitive crossplots of P-impedance and S-impedance contrasts across the BSR. They are calculated theoretically based on the effective medium theory for different hydrate distribution modes with some assumptions on porosity and mineralogical composition of unconsolidated sediments. This technique suggests the possibility of using the amplitude variation versus offset (AVO) analysis of the BSR for a quantitative interpretation when well log data are not available. By superimposing the AVO-derived P-impedance and S-impedance contrasts across the BSR on these RTs, the saturations of the hydrate and free gas near the BSR could be estimated. Validation of this approach by synthetic data showed that a reliable quantification could be achieved if the model parameters were rearranged to a form in which the AVO inversion was independent of the S-wave to P-wave velocity-ratio assumption. Based on this approach applied on the 2D marine pre-stack time migrated seismic line in offshore Iran, 4% to 28% of the gas hydrate and 1% to 2% of the free gas are expected to be accumulated near the thrusted-ridge and thrusted-footwall types of BSRs. (paper)

  9. Advancing New 3D Seismic Interpretation Methods for Exploration and Development of Fractured Tight Gas Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    James Reeves

    2005-01-31

    In a study funded by the U.S. Department of Energy and GeoSpectrum, Inc., new P-wave 3D seismic interpretation methods to characterize fractured gas reservoirs are developed. A data driven exploratory approach is used to determine empirical relationships for reservoir properties. Fractures are predicted using seismic lineament mapping through a series of horizon and time slices in the reservoir zone. A seismic lineament is a linear feature seen in a slice through the seismic volume that has negligible vertical offset. We interpret that in regions of high seismic lineament density there is a greater likelihood of fractured reservoir. Seismic AVO attributes are developed to map brittle reservoir rock (low clay) and gas content. Brittle rocks are interpreted to be more fractured when seismic lineaments are present. The most important attribute developed in this study is the gas sensitive phase gradient (a new AVO attribute), as reservoir fractures may provide a plumbing system for both water and gas. Success is obtained when economic gas and oil discoveries are found. In a gas field previously plagued with poor drilling results, four new wells were spotted using the new methodology and recently drilled. The wells have estimated best of 12-months production indicators of 2106, 1652, 941, and 227 MCFGPD. The latter well was drilled in a region of swarming seismic lineaments but has poor gas sensitive phase gradient (AVO) and clay volume attributes. GeoSpectrum advised the unit operators that this location did not appear to have significant Lower Dakota gas before the well was drilled. The other three wells are considered good wells in this part of the basin and among the best wells in the area. These new drilling results have nearly doubled the gas production and the value of the field. The interpretation method is ready for commercialization and gas exploration and development. The new technology is adaptable to conventional lower cost 3D seismic surveys.

  10. Evaluation of radiation dose during the percutaneous angioplasty for arteriovenous shunt assembling

    International Nuclear Information System (INIS)

    Ting, Chien-Yi; Wu, Wen-Shiann; Tang, Kuo-Ting; Wang, Hsin-Ell; Lin, Chun-Chih

    2017-01-01

    Percutaneous angioplasty (PTA) for dysfunctional hemodialysis is usually performed by radiologists, but not cardiologists, in Taiwan, so that the radiation dose in patients and physicians are usually unknown and related studies are rare. In this study, we are pioneering an investigation into the radiation dose in percutaneous angioplasty for arteriovenous shunt assembling and the effect of RADPAD device, a lead-free surgical drape containing Bi and Ba, on the decrease of a radiation dose in the non-targeted organs of the patient and also the operator. The radiation dose in a typical digital subtraction angiography (DSA) by the PTA protocol under a fixed field of view (FOV), was measured with optically simulated luminescent dosimeters arranged in a PIXY RS-102 anthropomorphic phantom. The results indicate that there is a significant dose reduction at the hands (0.022±0.002 mGy before treatment vs. 0.014±0.001 mGy after treatment; P=0.021), but not at the lens (0.027±0.003 mGy before treatment vs. 0.018±0.001 mGy after treatment; P=0.058), and the gonads (0.026±0.003 mGy before treatment vs. 0.020±0.001 mGy after treatment; P=0.058), of the cardiologist/operator after treatment with the RADPAD drape. At the patient's abdomen, the dose significantly decreased from 1.597±0.104 mGy to 0.031±0.002 mGy (P<0.001) after treated with the RADPAD shield. For the chest, lens and thyroid in the patient, the doses were respectively 0.154±0.100 mGy (compared to 0.049±0.001 mGy after treated with the RADPAD drape; P=0.0002), 0.066±0.001 mGy (compared to 0.021±0.001 mGy after the RADPAD treatment; P=0.009), and 0.208±0.002 mGy (compared to 0.042±0.003 mGy after shielded with the RADPAD drape; P<0.0001), which represents an apparent reduction in dose. However, no significant difference was found in the dose-area product between before (179.9±0.1mGy.cm 2 ) and after (177.4±0.1mGy.cm 2 ) the treatment (P=0.38). In conclusion, the RADPAD drape significantly reduced

  11. Kas teie arvates tuleks Ülejõe pargid Emajõe vasakkaldal taashoonestada? / intervjueerinud Ivi Drikkit ja Jüri Saar

    Index Scriptorium Estoniae

    2011-01-01

    Vastasid: Mati Tolmoff, Veljo Ipits, Toomas Savi, Verni Loodmaa, Väino Kull, Toomas Kapp, Triin Anette Kaasik, Kristjan Karis, Hele Everaus, Margot Fjuk, Janika Mölder, Hannes Astok, Jaak Adamsoo, Martin Parmas, Toivo Kabanen, Oleg Nesterenko, Tõnu Ints, Piret Uluots, Peep Peterson, Marju Lauristin, Jarno Laur, Arno Arukask, Ülo Veldre, Toomas Jürgenstein, Veera Sirg, Maie Pastik, Elmut Paavel, Avo Rosenvald, Toivo Maimets, Peeter Tulviste, Joel Luhamets, Jüri Kõre, Ants Kask, Enn Tarto, Tarmo Punger, Merle Jääger, Vladimir Šokman, Boris Habramov, Jevgenia Lindevaldt, Harri Jallajas, Natalja Trošina, Olev Raju, Nikolai Põdramägi

  12. Pravice iz invalidskega zavarovanja - neskladnost 2. in 3. odstavka 66. člena ZPIZ-1 z Ustavo Republike Slovenije

    OpenAIRE

    Bele, Primož

    2012-01-01

    Republika Slovenija je socialna država, kar je navedeno v drugem členu Ustave Republike Slovenije1. Upoštevajoč navedeno, prvi odstavek 50. člena Ustave RS zagotavlja državljanom pravico do socialne varnosti, pod pogoji, ki jih določa zakon. Naveden člen Ustave RS obvezuje državo, da z zakonom uredi obvezna socialna zavarovanja, torej tudi invalidsko zavarovanje. Država je dolžna zagotoviti delovanje invalidskega zavarovanja, kar je storila z zakonom o pokojninskem in invalidsk...

  13. Analysis of Truss Frames by Method of the Stiffness Matrix

    Science.gov (United States)

    1990-12-01

    of the web members of the truss. There also are variations in the truss frame given by the geometric shape of the frame, also referred to in some...at the elastic center, 0 (Figure .3.2), are: R AX = Wix - Hot RBX W2x -Ho, RAY =WIY + Vo, (1) RBy WLy - Vo, MAB =- Mo + CH. + aVo + CMA, MBA =M - CH...o Co Ce Substituting the results of Equation (7) into Equations (1), x c D x RAY = Wix + + -- (eA - GO - D (8)C x C x C cx x cx AY a D RAY

  14. Acquisition and Retention of Team Coordination in Command-and-Control

    Science.gov (United States)

    2007-05-15

    transitioning from a trot to a gallop is identical to the transition from anti-phase to in-phase finger tapping , when considered from a dynamical systems...Team Coordination conserved and mixing taps extant information in new ways. The latter interpretation seems more plausible given that the relations of...5OC1~AA To e IoumatbJfoa ee b~ei b ROZ euuy (K(M) is t(W4 DU~ V 4W~f rQ~shI1JWIIX~rI~~al ft~l~f ~ DFMPC reiorys S-STR rrsnvukis to AVO 0 Eft twos

  15. Ada Compiler Validation Summary Report: Certificate Number 890711W1. 10109 Concurrent Computer Corporation C(3) Ada, Version R02-02.00 Concurrent Computer Corporation 3280 MPS

    Science.gov (United States)

    1989-07-11

    Wright-Patterson ATB Dayton, OH, USA Ada Joint Prograr Office United States De artment of Defense " * ’ , Washington, DC 2 301-3061 i4. I 10 k A$ -h-Y...dependent but is permitted by the Ada Standard. Six classes of tests are used. These tests are designed to perform checks at compile time, at link time...the direction of the AVF according to procedures establizhed by the Ada Joia ,, Program Office and administered by the Ada Validation Organization (AVO

  16. Measurement of Diaphragmatic Blood Flow and Oxygen Consumption in the Dog by the Kety-Schmidt Technique

    Science.gov (United States)

    Rochester, Dudley F.

    1974-01-01

    To assess energy expenditure of the diaphragm directly, a method was devised for percutaneous catheterization of the left inferior phrenic vein in dogs. Necropsy studies, including retrograde injection of india ink and measurement of radioactivity in diaphragmatic muscle strips, suggested that the territory drained by the inferior phrenic vein was uniformly perfused, and that there were no major anastomoses between this bed and adjacent ones. Diaphragmatic blood flow (˙Q di) was calculated from the integrated diaphragmatic arteriovenous difference of 85Kr by the Kety-Schmidt technique. Diaphragmatic oxygen consumption (˙Vo2 di) was determined as the product of ˙Q di and the diaphragmatic arteriovenous oxygen content difference [(A-V)O2 di]. When lightly anesthetized dogs breathed quietly, ˙Q di was 22±SD 6 ml/min/100 g, (A-V)O2 di was 6.1±SD 2.5 ml/100 ml, and ˙VO2 di averaged 1.2±SD 0.3 ml/min/100 g. This represented 1.0±SD 0.2% of total body oxygen consumption. ˙VO2 di remained relatively constant during quiet breathing, whereas ˙Q di varied directly with cardiac output and reciprocally with (A-V)O2 di. The oxygen consumption of the noncontracting diaphragm was 60±SD 20% of the level measured during quiet breathing. The energy expended by the diaphragm to support simple hyperventilation was small. A 100% increase in minute ventilation, induced by inhalation of 5% CO2 in 21% or 14% O2, increased ˙Q di 13%, (A-V)O2 di 19%, and ˙VO2 di 40%. The diaphragm consumed 0.13±SD 0.09 ml O2 for each additional liter of ventilation. In four dogs, pneumonia appeared to increase ˙VO2 both by increasing minute ventilation and by increasing the energy cost per liter of ventilation. PMID:4825221

  17. 1970. aastatel alustas arhitektidest sõprade ja kolleegide rühm... / Mari Laanemets

    Index Scriptorium Estoniae

    Laanemets, Mari, 1975-

    2008-01-01

    27.VI avatakse Eesti Arhitektuurimuuseumis Rotermanni soolalaos 1970. ja 1980. alguse eksperimentaalset arhitektuuripraktikat käsitlev näitus "Keskkond, objektid, kontseptsioonid. Tallinna kooli arhitektid 1972-1985". Näha saab Ülevi Eljandi, Ignar Fjuki, Veljo Kaasiku, Tiit Kaljundi, Vilen Künnapu, Leonhard Lapini, Avo-Himm Looveere, Kristin-Mari Looveere, Marika Lõokese, Jüri Okase, Jaan Olliku, Ain Padriku, Toomas Reinu, Andres Ringo, Sirje Runge, Harry Sheini, Tõnis Vindi ja Matti Õunapuu töid. Näituse kuraatorid Andres Kurg ja Mari Laanemets. Samas: "Uue arhitektuuri näituse programm" (1972)

  18. Naisiin kohdistuva parisuhdeväkivalta ja auttavat tahot

    OpenAIRE

    Özen, Saija; Taavitsainen, Riina

    2015-01-01

    Opinnäytetyön tarkoituksena oli kerätä tietoa naisiin kohdistuvasta parisuhdeväkivallasta Suomessa. Keskityimme parisuhdeväkivaltaan suhteissa, joissa avo- tai aviopuolisoilla ei ole lapsia ja joissa mies on pahoinpitelijän roolissa. Tarkoituksena oli kerätä tietopaketti, jossa käymme läpi parisuhdeväkivaltaa ja sen monimuotoisuutta, avun hakemisen ja saamisen vaikeutta sekä auttamisprosessia parisuhdeväkivaltatyössä. Opinnäytetyömme teoriaosuudessa käsiteltiin parisuhdeväkivaltaa ilmiö...

  19. Kvadroraadio 40 / Margo Kõlar

    Index Scriptorium Estoniae

    Kõlar, Margo, 1961-

    2017-01-01

    40 aastat tagasi edastas Eesti Raadio eetrisse esimese kvadrofoonilise otsesaate tollases Nõukogude Liidus. Sündmust meenutavad psühholoog ja elektroonikainsener, tollane Vabariikliku Raadio- ja Telekeskuse sektori juhataja Avo-Rein Tereping ning mitu häält aegade tagant: ENSV Raadio ja Televisiooni Komitee esimehe esimene asetäitja Aado Slutsk, raadio- ja muusikaajakirjanik Virve Normet, Eesti Raadio programmi peadirektori asetäitja Hannes Valdma, reporter Toivo Makk, aastail 1975-1981 raadio muusikasaadete peatoimetajana töötanud tšellist Toomas Velmet ning loodusemees Fred Jüssi

  20. Uporaba nabora multimedijskih orodij za mednarodno predstavitev mostu "Pašerele" čez reko Sočo na Goriškem

    OpenAIRE

    POPIT, DIJANA

    2017-01-01

    V pričujočem delu je predstavljen potek projekta, ki smo ga začeli izvajati v maju 2014 pod mentorstvom dr. Franca Policardija, glavnega distributerja uporabljenega gradiva g. Maria Mute ter g. Petra Gruntarja, ki nam je pomagal pri rekonstrukciji mostu v AvtoCAD-u 2012. Problem našega projekta je bil kako z uporabo standardnih metod in multimedije zabrisati mejo, ki je nastala med Slovenijo in Italijo, bolj natančno med potomci ljudi, ki so nekdaj živeli pod skupno državo Avstro-Ogrsko. O...

  1. Press Meeting 20 January 2003: First Light for Europe's Virtual Observatory

    Science.gov (United States)

    2002-12-01

    Imagine you are an astronomer with instant, fingertip access to all existing observations of a given object and the opportunity to sift through them at will. In just a few moments, you can have information on all kinds about objects out of catalogues all over the world, including observations taken at different times. Over the next two years this scenario will become reality as Europe's Astrophysical Virtual Observatory (AVO) develops. Established only a year ago (cf. ESO PR 26/01), the AVO already offers astronomers a unique, prototype research tool that will lead the way to many outstanding new discoveries. Journalists are invited to a live demonstration of the capabilities of this exciting new initiative in astronomy. The demonstration will take place at the Jodrell Bank Observatory in Manchester, in the United Kingdom, on 20 January 2003, starting at 11:00. Sophisticated AVO tools will help scientists find the most distant supernovae - objects that reveal the cosmological makeup of our Universe. The tools are also helping astronomers measure the rate of birth of stars in extremely red and distant galaxies. Journalists will also have the opportunity to discuss the project with leading astronomers from across Europe. The new AVO website has been launched today, explaining the progress being made in this European Commission-funded project: URL: http://www.euro-vo.org/ To register your intention to attend the AVO First Light Demonstration, please provide your name and affiliation by January 13, 2003, to: Ian Morison, Jodrell Bank Observatory (full contact details below). Information on getting to the event is included on the webpage above. Programme for the AVO First Light Demonstration 11:00 Welcome, Phil Diamond (University of Manchester/Jodrell Bank Observatory) 11:05 Short introduction to Virtual Observatories, Piero Benvenuti (ESA/ST-ECF) 11:15 Q&A 11:20 Short introduction to the Astrophysical Virtual Observatory, Peter Quinn (ESO) 11:30 Q&A 11:35 Screening of

  2. Vasserman ja Keerend rahvusvahelistel näitustel / Benjamin Vasserman

    Index Scriptorium Estoniae

    Vasserman, Benjamin

    2001-01-01

    17. VI-2. IX Kanada Quebeci provintsis Trois-Riviere'is toimuval II rahvusvahelisel graafikabiennaalil osaleb Benjamin Vasserman 7 graafilise lehega. Peapreemia - Tomoya Uchida graafiline sari "Nest". Valiknäituse "Triennial of One Hundred Cities" esimesel väljapanekul Dzierzoniowis osalesid Avo Keerend ja B. Vasserman, A. Keerendi töö "Vastasseis XII" on avaldatud näituse bukleti esikaanel. Itaalias Pisas 7.-14. VII toimunud III ülemaailmsel väikegraafika ja -maali näitusel "ITART 2001" pälvis B. Vassermani "Finalist" diplomi ja õiguse osaleda finalistide preemianäitusel Livornos.

  3. Parisuhdemuodon vaikutus perimykseen ja verotukseen

    OpenAIRE

    Paviala, Katriina

    2016-01-01

    Tässä opinnäytteessä tutkittiin parisuhdemuodon vaikutusta perimykseen ja verotukseen. Päätarkoituksena oli koota yhteen avioliiton verohyödyt ja tuoda esiin avo- ja avioliiton erot verotuksen ja perimyksen näkökulmasta. Tavoitteena oli, että työn luettuaan lukijalla on selkeä käsitys avioliiton eduista perimyksessä ja verotuksessa. Tutkimusmenetelmänä käytettiin kvalitatiivisia menetelmiä ja lainopillisia keinoja. Laadullisista tutkimusmenetelmistä hyödynnettiin tapaustutkimusta. Lähdemat...

  4. Eesti graafika rahvusvahelistel näitustel

    Index Scriptorium Estoniae

    2003-01-01

    Inga Heamägi ja Benjamin Vasserman osalevad 3. X-4. XII Bangkokis rahvusvahelisel graafika ja joonistuste näitusel "Interprint". Peapreemia - Katarina Vavrova Slovakkiast. 2003. a. Krakovi graafikatriennaalil pälvis peapreemia Davida Kidd Kanadast, aupeapreemia Toshihiro Hamano Jaapanist, Saksa panga preemia Eve Kask, Eestist osalevad näitusel I. Heamägi, Avo Keerend, Silvi Liiva, Ülle Marks ja Jüri Kass, Vive Tolli, Kelli Valk (Kagovere), B. Vasserman, näitusel "Intergrafia 2003" Niepolomice muuseumis osalevad Eestist A. Keerend, Peeter Laurits, Ü. Marks ja J. Kass, Andres Tali, V. Tolli, B. Vasserman, Vello Vinn

  5. Razvijmo sebe, druge in s tem svoj kraj

    Directory of Open Access Journals (Sweden)

    Dušana Findeisen

    1997-12-01

    Full Text Available Dušana Findeisen v tem prispevku obravnava vprašanje, kako spodbuditi ljudi k soodgovornosti za lasten razvoj in razvoj kraja. Preučuje tudi, kako naj prebivalci postanejo soodgovorni za zadostitev lastnih potreb in potreb njihovega kraja. V zvezi s tem se dotakne vloge izobraževalca odraslih - animatorja lokalnih projektov. Poudarja tudi pomen navezovanja novih odnosov in razmerij med lokalnimi skupnostmi in državo ter uvajanje “strukturalne politike”, kot jo imenuje avtorica, za sistemsko pomoč razvoju lokalnih projektov. Nazadnje pa obravnava vlogo lokalnih projektov z vidika razvoja kraja.

  6. Determining and managing fetal radiation dose from diagnostic radiology procedures in Turkey

    International Nuclear Information System (INIS)

    Ozbayrak, Mustafa; Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa

    2015-01-01

    We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion

  7. Cultural differences in postnatal quality of life among German-speaking women - a prospective survey in two countries.

    Science.gov (United States)

    Grylka-Baeschlin, Susanne; van Teijlingen, Edwin; Gross, Mechthild M

    2014-08-15

    Assessment of quality of life after childbirth is an important health-outcome measurement for new mothers and is of special interest in midwifery. The Mother-Generated Index (MGI) is a validated instrument to assess postnatal quality of life. The tool has not been applied for making a cross-cultural comparison before. This study investigated (a) responses to the MGI in German-speaking women in Germany and Switzerland; and (b) associations between MGI scores on the one hand and maternity and midwifery care on the other. A two-stage survey was conducted in two rural hospitals 10 km apart, on opposite sides of the German-Swiss border. The questionnaires included the MGI and questions on socio-demographics, physical and mental health and maternity care, and were distributed during the first days after birth and six weeks postpartum. Parametric and non-parametric tests were computed with the statistical programme SPSS. A total of 129 questionnaires were returned an average of three days after birth and 83 in the follow-up after seven weeks. There were no statistically significant differences in the MGI scores between the German and the Swiss women (p = 0.22). Significantly more favourable MGI scores were found associated with more adequate information during pregnancy (p = 0.02), a more satisfactory birth experience (p German-speaking women were higher than those in other studies reported previously. Thus the tool may be able to detect differences in postnatal quality of life among women with substantially divergent cultural backgrounds. Shortcomings in maternity and midwifery care were detected, as for example the inadequate provision of information during pregnancy, a lack of individualised postpartum care during the hospital stay and insufficient support for exclusively breastfeeding mothers. The MGI is an appropriate instrument for maternity care outcome measurement in cross-cultural comparison research.

  8. Assessment of Patients’ Entrance Skin Dose from Diagnostic X-ray Examinations at Public Hospitals of Akwa Ibom State, Nigeria

    Directory of Open Access Journals (Sweden)

    Esen Nsikan U

    2015-07-01

    Full Text Available Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State, Nigeria. Materials and Methods In total, six examinations were performed on 720 patients in this study.   CALDose_X5 software program was used in estimating ESDs based on patients’ information and technical exposure parameters. Results The estimated ESDs ranged from 0.59 to 0.61 mGy for PA and RLAT projections of the thorax, respectively. ESDs for the AP and RLAT projections of the cranium were 1.65 and 1.48 mGy, respectively. Also, ESD values for the AP view of the abdomen and pelvis were 1.89 and 1.88 mGy, respectively. The mean effective dose was within the range of 0.021-0.075 mGy for the thorax (mean= 0.037, 0.008-0.045 mGy for the cranium (mean= 0.016, 0.215-0.225 mGy for the abdomen (mean= 0.219 and 0.101-0.119 mGy for the pelvis (mean= 0.112. Conclusion The obtained results were comparable to the international reference dose levels, except for the PA projection of the thorax. Therefore, quality assurance programs are required in diagnostic X-ray units of Nigeria hospitals. The obtained findings add to the available data and can help authorities establish reference dose levels for diagnostic radiography in Nigeria.

  9. The long-term effects of acute exposure to ionising radiation on survival and fertility in Daphnia magna

    International Nuclear Information System (INIS)

    Sarapultseva, Elena I.; Dubrova, Yuri E.

    2016-01-01

    The results of recent studies have provided strong evidence for the transgenerational effects of parental exposure to ionising radiation and chemical mutagens. However, the transgenerational effects of parental exposure on survival and fertility remain poorly understood. To establish whether parental irradiation can affect the survival and fertility of directly exposed organisms and their offspring, crustacean Daphnia magna were given 10, 100, 1000 and 10,000 mGy of acute γ-rays. Exposure to 1000 and 10,000 mGy significantly compromised the viability of irradiated Daphnia and their first-generation progeny, but did not affect the second-generation progeny. The fertility of F 0 and F 1 Daphnia gradually declined with the dose of parental exposure and significantly decreased at dose of 100 mGy and at higher doses. The effects of parental irradiation on the number of broods were only observed among the F 0 Daphnia exposed to 1000 and 10,000 mGy, whereas the brood size was equally affected in the two consecutive generations. In contrast, the F 2 total fertility was compromised only among progeny of parents that received the highest dose of 10,000 mGy. We propose that the decreased fertility observed among the F 2 progeny of parents exposed to 10,000 mGy is attributed to transgenerational effects of parental irradiation. Our results also indicate a substantial recovery of the F 2 progeny of irradiated F 0 Daphnia exposed to the lower doses of acute γ-rays. - Highlights: • Viability of irradiated daphnids and their F 1 progeny is compromised. • Viability of the F 2 progeny of irradiated parents is not affected. • Total fertility of irradiated daphnids and their F 1 progeny declines with the dose. • Total fertility of the F 2 progeny of parents exposed to 10,000 mGy is compromised. • The decreased fertility among the F 2 progeny is transgenerational phenomenon.

  10. Determining and managing fetal radiation dose from diagnostic radiology procedures in Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Ozbayrak, Mustafa; Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa [Istanbul University, Istanbul (Turkmenistan)

    2015-12-15

    We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion.

  11. Electron beam irradiation effects on carbon fiber reinforced PEEK composite

    International Nuclear Information System (INIS)

    Sasuga, Tsuneo; Hagiwara, Miyuki; Odajima, Tosikazu; Sakai, Hideo; Nakakura, Toshiyuki; Masutani, Masahiro.

    1987-03-01

    Carbon fiber(CF) reinforced composites, using polyarylether-sulfone (PES) or polyarylether-ether-ketone (PEEK) as matrix material, were prepared and their electron beam irradiation effects were studied on the basis of changes in mechanical and dynamic viscoelastic properties and observation of fracture surfaces. The flexural strength of PES-CF composite decreased to 70 % of the initial strength after the irradiation of 3 MGy and 40 % after 15 MGy. The change in the profile of stress-strain (S-S) curves and fractographic observation by electron microscopy indicated that this composite irradiated with over 3 MGy was fractured by delamination caused by to the degradation of matrix polymer. The mechanical properties of PEEK-CF composite were scarcely decreased even after irradiated up to 180 MGy and this composite showed very high radiation resistance. The change in the profile of S-S curves and fractographic observation showed that this composite fractured due to destruction of fiber in the dose range less than 180 MGy, indicating that PEEK was excellent matrix material used in high radiation field. PEEK-PES-CF composite which was composed of the carbon fibers coated with PES solution showed less radiation resistance compared with PEEK-CF composite; the flexural strength decreased to 85 % of the initial value after the irradiation with 90 MGy. It was revealed from the changes in the profile of S-S curve that the specimen irradiated over 120 MGy was fractured due to not only fiber destruction but delamination. Deterioration mechanism of PEEK-PES-CF composite was studied by dynamic viscoelastic measurements in connection with the damage on matrix-fiber interface. It was suggested that the deterioration in mechanical properties of this composite was caused by the degradation of PES that coated on the surface of the carbon fibers. (author)

  12. Dose response relationship for unstable-type chromosome aberration rate of spleen cells from mice continuously exposed to low-dose-rate gamma-rays

    International Nuclear Information System (INIS)

    Tanaka, Kimio; Khoda, Atsushi; Ichinohe, Kazuaki; Oghiso, Yoichi

    2007-01-01

    It has been reported that people who are chronically exposed to radiation such as nuclear facility workers and medical radiologists have slightly higher incidences of chromosome aberrations than non-exposed people. However, chronological changes of chromosome aberration rates related to accumulated doses and dose-rates for low dose-rate radiation exposures have not been well studied. Precise analyses of human populations are quite limited because confounding factors influence the results. For this reason, animal experiments are important for analyses. Mice were continuously exposed to gamma-rays at 400 mGy/22 hr/day for 10 days, 20 mGy/22 hr/day for about 400 days, and 1 mGy/22 hr/day for about 615 days under SPF conditions. Chronological changes of unstable-type chromosome aberration rates of spleen cells were observed along with accumulated doses at the middle dose rate and the two low-dose rates by conventional Giemsa-staining method. Aberrations such as dicentric chromosome, ring chromosome and fragment increased in a two-phase manner within 0-1.2 Gy and 2-8 Gy at 20 mGy/22 hr/day. They slightly increased up to 0.5 Gy at 1 mGy/22 hr/day. Aberration rates for 1, 2, 8 Gy at the 20 mGy/22 hr/day and for 0.5 Gy at 1 mGy/22 hr/day were 5.1, 9.6, 13.9 and 2.2 times higher than those of age-matched, non-irradiated control mice, respectively. Chromosome aberration rates at 400 mGy/22 hr/day were 2.7 times higher than that of 20 mGy/22 hr/day for the same total dose of 1.2 Gy. The results that unstable-type chromosome aberrations increased with accumulated dose of the low-dose rate radiation will be important to establish biological dosimetry for people who are chronically exposed to radiation. (author)

  13. Photon hormesis deactivates alpha-particle induced bystander effects between zebrafish embryos

    International Nuclear Information System (INIS)

    Ng, C.Y.P.; Cheng, S.H.; Yu, K.N.

    2017-01-01

    In the present work, we studied the effects of low-dose X-ray photons on the alpha-particle induced bystander effects between embryos of the zebrafish, Danio rerio. The effects on the naive whole embryos were studied through quantification of apoptotic signals (amounts of cells undergoing apoptosis) at 24 h post fertilization (hpf) using vital dye acridine orange staining, followed by counting the stained cells under a fluorescent microscope. We report data showing that embryos at 5 hpf subjected to a 4.4 mGy alpha-particle irradiation could release a stress signal into the medium, which could induce bystander effect in partnered naive embryos sharing the same medium. We also report that the bystander effect was deactivated when the irradiated embryos were subjected to a concomitant irradiation of 10 or 14 mGy of X-rays, but no such deactivation was achieved if the concomitant X-ray dose dropped to 2.5 or 5 mGy. In the present study, the significant drop in the amount of apoptotic signals on the embryos having received 4.4 mGy alpha particles together X-rays irradiation from 2.5 or 5 mGy to 10 or 14 mGy, together with the deactivation of RIBE with concomitant irradiation of 10 or 14 mGy of X-rays supported the participation of photon hormesis with an onset dose between 5 and 10 mGy, which might lead to removal of aberrant cells through early apoptosis or induction of high-fidelity DNA repair. As we found that photons and alpha particles could have opposite biological effects when these were simultaneously irradiated onto living organisms, these ionizing radiations could be viewed as two different environmental stressors, and the resultant effects could be regarded as multiple stressor effects. The present work presented the first study on a multiple stressor effect which occurred on bystander organisms. In other words, this was a non-targeted multiple stressor effect. The photon hormesis could also explain some failed attempts to observe neutron-induced bystander

  14. Radiation induced micrencephaly in guinea pigs

    International Nuclear Information System (INIS)

    Wagner, L.K.; Johnston, D.A.; Felleman, D.J.

    1991-01-01

    A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays at doses of 75-mGy during this late embryonic stage of development is consistent with the findings of small head size induced in those exposed prior to the eight week of conception at Hiroshima. This implies a mechanism for micrencephaly different from those previously suggested and lends credence to a causal relation between radiation and small head size in humans at low doses as reported by Miller and Mulvihill. 16 refs., 13 tabs

  15. The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysis

    International Nuclear Information System (INIS)

    Wieser, A.; Debuyst, R.; Fattibene, P.

    2005-01-01

    The objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 11 molars, which were cut into two halves. One half of each tooth was irradiated in a 60 Co beam to doses in the ranges of 30-100 mGy (5 samples), 100-300 mGy (5 samples), and 300-900 mGy (1 sample). Fourteen international laboratories participated in this intercomparison programme. A first analysis of the results and an overview of the essential features of methods applied in different laboratories are presented. The relative standard deviation of results of all methods was better than 27% for applied doses in the range of 79-704 mGy. In the analysis of the unirradiated tooth halves 8% of the samples were identified as outliers with additional absorbed dose above background dose

  16. Clinical indications and radiation doses to the conceptus associated with CT imaging in pregnancy: a retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Woussen, S.; Vanbeckevoort, D.; Bosmans, H.; Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Lopez-Rendon, X.; Zanca, F. [University Hospitals Leuven, Department of Imaging and Pathology, Leuven (Belgium)

    2016-04-15

    To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus. A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data. The number of CT examinations during pregnancy increased from 3-4 per year in 2008-2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7-60.5 mGy). The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy. (orig.)

  17. Patient dosimetry study of a paediatric CT examination

    International Nuclear Information System (INIS)

    Hranitzky, C.; Stadtmann, H.

    2011-01-01

    Dosimetry studies are of increasing interest in diagnostic high-dose applications such as computed tomography especially for examinations of children. A routine CT scan protocol for paediatric head and neck imaging was investigated at a new multi-detector CT scanner using LiF:Mg,Cu,P thermoluminescence dosemeters (TLDs) and a 0.125 cm 3 thimble ionization chamber. Calibrations of the detectors in terms of absorbed dose to water were carried out at the Dosimetry Laboratory Seibersdorf in standard radiation fields. The dosimetry method was validated in the spiral CT X-ray field by comparing TLD and ionization chamber measurement results in cylindrical PMMA phantoms. Absorbed dose results were within stated uncertainties. An anthropomorphic phantom representing a child of about 5 years was loaded with TLD chips at various organ and tissue positions in the head and neck region as well as at some critical organ locations. Organ dose values were calculated from TLD based average absorbed dose with about 5% total uncertainty, e.g. 22 mGy (eyes), 21 mGy (thyroid), 19 mGy (brain), 3.4 mGy (thymus), and 0.03 mGy (testes). For comparison purposes an effective dose of 1.9 mSv was estimated for the investigated paediatric CT examination based on ICRP-103 age-independent tissue-weighting factors.

  18. Reference dose levels for dental panoramic radiography in Anyang City

    International Nuclear Information System (INIS)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja; Lee, Jae Seo; Kim, Young Hee

    2009-01-01

    To measure dose-width product (DWP) values used for dental panoramic radiography in Anyang city, Korea. Thirty-six panoramic dental radiographic sets (17 analogue panoramic sets and 19 digital panoramic sets) in 36 dental clinics in Anyang city were included in the study. Each patient's panoramic exposure parameters were simulated and the panoramic radiation doses were measured at the secondary collimator using a Mult-O-Meter (Unfors Instruments, Billdal, Sweden) at each dental clinic during 2006. The third quartile DWP was determined from 310 surface dose measurements on adult. The third quartile DWP for adult panoramic radiograph was 106.7 mGy mm. For analogue and digital panoramic radiograph, 3/4 DWP were 116.8 mGy mm and 72 mGy mm respectively. The overall third quartile DWP of panoramic radiography was 106.7 mGy mm. The measured 3/4 DWPs were higher than the 3/4 DWP of 65 mGy mm recommended by NRPB. Dentists who are operating above the reference dose should lower their panoramic exposure doses below the recommended reference value by changing the exposure parameters and/or their panoramic equipment.

  19. Environmental effects of radionuclides--observations on natural ecosystems.

    Science.gov (United States)

    Copplestone, D; Toal, M E; Johnson, M S; Jackson, D; Jones, S R

    2000-03-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides 137Cs, 238Pu, 239+240Pu and 241Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d(-1)) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0 x 10(-3) mGy d(-1), 2.2 x 10(-3) mGy d(-1) and 1.0 x 10(-3) mGy d(-1) respectively. The values are at least three orders of magnitude lower than the 1 mGy d(-1) level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed.

  20. Diagnostic reference levels in intraoral radiology: From the laboratory to clinical practice

    International Nuclear Information System (INIS)

    Alcaraz, M.; Velasco, E.; Martinez-Beneyto, Y.; Velasco, F.; Parra, C.; Canteras, M.

    2010-01-01

    To determine the diagnostic reference levels (DRLs) for obtaining a diagnostic image in the normal conditions of clinical practice and to explain the differences between the levels found and the DRLs obtained in other experimental conditions, suggesting that there has been a reduction in the European Union (EU) recommended levels. A total of 2296 official reports on dental surgeries from 16 Spanish autonomous regions compiled during 2008 were studied. A mean DRL of 3.3 mGy was determined: 2.6 mGy for installations using direct digital systems, 3.4 mGy for those using indirect systems, 4.4 mGy for those using Ultra-speed film and 3.7 mGy for those using Insight. The DRLs found in this survey are below the EU recommended values but far above previously described values, possibly because all the different systems were considered and because values refer to those of the normal work conditions of clinical practice. (authors)

  1. Environmental effects of radionuclides - observations on natural ecosystems

    International Nuclear Information System (INIS)

    Copplestone, D.; Toal, M.E.; Johnson, M.S.; Jackson, D.; Jones, S.R.

    2000-01-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides 137 Cs, 238 Pu, 239+240 Pu and 241 Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d -1 ) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0x10 -3 mGy d -1 , 2.2x10 -3 mGy d -1 and 1.0x10 -3 mGy d -1 respectively. The values are at least three orders of magnitude lower than the 1 mGy d -1 level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed. (author)

  2. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology

    Science.gov (United States)

    Fiedler, S.; Bravin, A.; Keyriläinen, J.; Fernández, M.; Suortti, P.; Thomlinson, W.; Tenhunen, M.; Virkkunen, P.; Karjalainen-Lindsberg, M.-L.

    2004-01-01

    Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

  3. Increased apoptosis and DNA double-strand breaks in the embryonic mouse brain in response to very low-dose X-rays but not 50 Hz magnetic fields

    Science.gov (United States)

    Saha, Shreya; Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Ricket, Nicole; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2014-01-01

    The use of X-rays for medical diagnosis is enhancing exposure to low radiation doses. Exposure to extremely low-frequency electromagnetic or magnetic fields is also increasing. Epidemiological studies show consistent associations of childhood leukaemia with exposure to magnetic fields but any causal relationship is unclear. A limitation in assessing the consequence of such exposure is the availability of sensitive assays. The embryonic neuronal stem and progenitor cell compartments are radiosensitive tissues. Using sensitive assays, we report a statistically significant increase in DNA double-strand break (DSB) formation and apoptosis in the embryonic neuronal stem cell compartment following in utero exposure to 10–200 mGy X-rays. Both endpoints show a linear response. We also show that DSB repair is delayed following exposure to doses below 50 mGy compared with 100 mGy. Thus, we demonstrate in vivo consequences of low-dose radiation. In contrast to these impacts, we did not observe any significant induction of DSBs or apoptosis following exposure to 50 Hz magnetic fields (100 or 300 µT). We conclude that any DSB induction by treatment with magnetic fields is lower than following exposure to 10 mGy X-rays. For comparison, certain procedures involving computed tomography scanning are equivalent to 1–5 mGy X-rays. PMID:25209403

  4. Effects of Low Versus Moderate Glycemic Index Diets on Aerobic Capacity in Endurance Runners: Three-Week Randomized Controlled Crossover Trial

    Directory of Open Access Journals (Sweden)

    Krzysztof Durkalec-Michalski

    2018-03-01

    Full Text Available The glycemic index (GI of ingested carbohydrates may influence substrate oxidation during exercise and athletic performance. Therefore, the aim of this study was to assess the effect of low- and moderate-GI three-week diets on aerobic capacity and endurance performance in runners. We conducted a randomized crossover feeding study of matched diets differing only in GI (low vs. moderate in 21 endurance-trained runners. Each participant consumed both, low- (LGI and moderate-GI (MGI high-carbohydrate (~60% and nutrient-balanced diets for three weeks each. At the beginning and end of each diet, participants had their aerobic capacity and body composition measured and performed a 12-min running test. After LGI, time to exhaustion during incremental cycling test (ICT and distance covered in the 12-min run were significantly increased. The MGI diet led to an increase in maximal oxygen uptake ( V ˙ O2max, but no performance benefits were found after the MGI diet. The LGI and MGI diets improved time and workload at gas exchange threshold (GET during ICT. The results indicate that a three-week high-carbohydrate LGI diet resulted in a small but significant improvement in athletic performance in endurance runners. Observed increase in V ˙ O2max on MGI diet did not affect performance.

  5. Environmental effects of radionuclides - observations on natural ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Copplestone, D. [Industrial Ecology Research Centre, School of Biological Sciences, University of Liverpool, Liverpool L69 3BX (United Kingdom). E-mail: copplest at liv.ac.uk; Toal, M.E.; Johnson, M.S. [Industrial Ecology Research Centre, School of Biological Sciences, University of Liverpool, Liverpool L69 3BX (United Kingdom); Jackson, D.; Jones, S.R. [Westlakes Scientific Consulting, Princess Royal Building, Westlakes Science and Technology Park, Moor Row, Cumbria CA24 3LN (United Kingdom)

    2000-03-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides {sup 137}Cs, {sup 238}Pu, {sup 239+240}Pu and {sup 241}Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d{sup -1}) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0x10{sup -3} mGy d{sup -1}, 2.2x10{sup -3} mGy d{sup -1} and 1.0x10{sup -3} mGy d{sup -1} respectively. The values are at least three orders of magnitude lower than the 1 mGy d{sup -1} level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed. (author)

  6. ESR dosimetry study for the residents of Kazakhstan exposed to radioactive fallout on 24, August 1956

    Energy Technology Data Exchange (ETDEWEB)

    Zhumadilov, K., E-mail: kassym@hiroshima-u.ac.jp [Research Institute for Radiation Biology and Medicine, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8553 (Japan); Ivannikov, A. [Medical Radiological Research Center, Obninsk 249036 (Russian Federation); Zharlyganova, D. [Astana Medical University, 51a, Beibitshilik str., Astana 010000 (Kazakhstan); Zhumadilov, Zh. [Nazarbayev University, Life Sciences Center, D. Kunayev str., Astana 010000 (Kazakhstan); Stepanenko, V. [Medical Radiological Research Center, Obninsk 249036 (Russian Federation); Abralina, Sh.; Sadvokasova, L. [Semey State Medical Academy, Semey 071400, Abay str. 103 (Kazakhstan); Zhumadilova, A. [Astana Medical University, 51a, Beibitshilik str., Astana 010000 (Kazakhstan); Toyoda, S. [Department of Applied Physics, Faculty of Science, Okayama University of Science, Okayama 700-0005 (Japan); Endo, S. [Department of Quantum Energy Applications, Graduated School of Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527 (Japan); Okamoto, T. [Department of Molecular Oral Medicine and Maxillofacial Surgery, Division of Frontier Medical Science, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima 734-8553 (Japan); Hoshi, M. [Research Institute for Radiation Biology and Medicine, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8553 (Japan)

    2011-09-15

    The method of electron spin resonance (ESR) dosimetry has been applied to human tooth enamel in order to obtain individual absorbed doses from the population of settlements within the vicinity of the central axis of the radioactive fallout trace from the contaminating nuclear surface test of 24, August 1956. Most of the settlements (Glubokoe, Tavriya, and Gagarino) are located near Ust-Kamenogorsk city, in Kazakhstan (about 400 km to the east from the epicenter of the explosion at the Semipalatinsk Nuclear Test Site (SNTS)). It was found that the excess doses obtained after the subtraction of natural background radiation ranged up to about 120 mGy for the residents of Ust-Kamenogorsk city, whose tooth enamel was formed before 1956. For the residents of Gagarino, excess doses do not exceed 47 mGy for all ages. For the residents of Tavriya, the maximum of excess dose was determined as 54 mGy and for the residents of Glubokoe, the maximum excess dose was about 83 mGy. For the population of the Shemonaikha settlements (about 70 km from the centerline of the radioactive fallout trace) the highest excess dose is 110 mGy. Also for this study, Znamenka village (about 130 km from the epicenter) was included. The Kokpekty settlement was chosen as a control and not subjected to any radioactive contamination and is located 400 km to the Southeast from SNTS.

  7. Increased apoptosis and DNA double-strand breaks in the embryonic mouse brain in response to very low-dose X-rays but not 50 Hz magnetic fields.

    Science.gov (United States)

    Saha, Shreya; Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Ricket, Nicole; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2014-11-06

    The use of X-rays for medical diagnosis is enhancing exposure to low radiation doses. Exposure to extremely low-frequency electromagnetic or magnetic fields is also increasing. Epidemiological studies show consistent associations of childhood leukaemia with exposure to magnetic fields but any causal relationship is unclear. A limitation in assessing the consequence of such exposure is the availability of sensitive assays. The embryonic neuronal stem and progenitor cell compartments are radiosensitive tissues. Using sensitive assays, we report a statistically significant increase in DNA double-strand break (DSB) formation and apoptosis in the embryonic neuronal stem cell compartment following in utero exposure to 10-200 mGy X-rays. Both endpoints show a linear response. We also show that DSB repair is delayed following exposure to doses below 50 mGy compared with 100 mGy. Thus, we demonstrate in vivo consequences of low-dose radiation. In contrast to these impacts, we did not observe any significant induction of DSBs or apoptosis following exposure to 50 Hz magnetic fields (100 or 300 µT). We conclude that any DSB induction by treatment with magnetic fields is lower than following exposure to 10 mGy X-rays. For comparison, certain procedures involving computed tomography scanning are equivalent to 1-5 mGy X-rays.

  8. 18FDG PET in a pregnant patient

    International Nuclear Information System (INIS)

    Chatterton, Barry

    2006-01-01

    A 26-year-old pregnant female presented with cervical adenopathy which was shown on biopsy to be Hodgkin's disease. As she had some systemic symptoms, It was decided to further stage her disease, with the options being allowing the pregnancy to continue, or terminating the pregnancy and treating immediately. To keep the radiation dose as low as possible, the administered dose of l8 FDG was reduced giving a total estimated dose to the fetus as 3.2 mGy and l37 Cs used as the source for attenuation correction rather than CT (dose estimated as 0.15mGy instead of 1.5 mGy) Total dose to the fetus was estimated as 3.4mGy. ICRP indicates that termination of pregnancy is not justified for radiation doses less than 100mGy. The findings confirm that an indicated PET scan may be performed in pregnancy at acceptable radiation dose. Relatively straightforward modification of the standard scanning protocol will reduce the estimated fetal dose. Copyright (2006) The Australian and New Zealand Society of Nuclear Medicine

  9. Dose distribution over the radiation field and organs of the body during radiotherapy procedures

    International Nuclear Information System (INIS)

    Roy, S.; Begum, M.; Ambia, A.S.M.; Akhter, S.; Banu, H.

    2001-01-01

    Beam profile of the 60 Co teletherapy unit for 10 cm x 10 cm along central axis was measured to study the symmetry of the gamma beam and found that the average dose was 98.44±1.40 mGy. Output dose versus field size was also measured and values were found reasonable. Dose prescription to delivery was measured by placing TLD onto the treatment field for lung and cervix cancer patient which was found to be 39.16±2.98 Gy and 50.48±3.68 Gy respectively which are within 2 % and 0.17 % of the prescribed dose as 40.00 and 50.40 Gy respectively, reveals good agreement with the treatment planning. Six typical types of patients (both male and female) with cancers in lung, larynx, breast, cervix, oesophagus and brain treated with 60 Co teletherapy were particularly considered for dose assessment at different critical organs of interest. It was observed that the doses to the lens of eye with a maximum value of 460.35+78.87 mGy for a larynx cancer patient to a minimum value of 30.80+4.00 mGy of a cervix cancer patient. Doses to the gonad vary with a maximum value of 3810.80+389.76 mGy for a cervix cancer patient to a minimum value of 8.20+1.00 mGy for a brain cancer patient. (author)

  10. Hibiscus sabdariffa leaf polyphenolic extract induces human melanoma cell death, apoptosis, and autophagy.

    Science.gov (United States)

    Chiu, Chun-Tang; Hsuan, Shu-Wen; Lin, Hui-Hsuan; Hsu, Cheng-Chin; Chou, Fen-Pi; Chen, Jing-Hsien

    2015-03-01

    Melanoma is the least common but most fatal form of skin cancer. Previous studies have indicated that an aqueous extract of Hibiscus sabdariffa leaves possess hypoglycemic, hypolipidemic, and antioxidant effects. In this study, we want to investigate the anticancer activity of Hibiscus leaf polyphenolic (HLP) extract in melanoma cells. First, HLP was exhibited to be rich in epicatechin gallate (ECG) and other polyphenols. Apoptotic and autophagic activities of HLP and ECG were further evaluated by DAPI stain, cell-cycle analysis, and acidic vascular organelle (AVO) stain. Our results revealed that both HLP and ECG induced the caspases cleavages, Bcl-2 family proteins regulation, and Fas/FasL activation in A375 cells. In addition, we also revealed that the cells presented AVO-positive after HLP treatments. HLP could increase the expressions of autophagy-related proteins autophagy-related gene 5 (ATG5), Beclin1, and light chain 3-II (LC3-II), and induce autophagic cell death in A375 cells. These data indicated that the anticancer effect of HLP, partly contributed by ECG, in A375 cells. HLP potentially could be developed as an antimelanoma agent. © 2015 Institute of Food Technologists®

  11. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRIBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    International Nuclear Information System (INIS)

    Michael G. Waddell; William J. Domoracki; Tom J. Temples; Jerome Eyer

    2001-01-01

    The Earth Sciences and Resources Institute, University of South Carolina is conducting a 14 month proof of concept study to determine the location and distribution of subsurface Dense Nonaqueous Phase Liquid (DNAPL) carbon tetrachloride (CCl 4 ) contamination at the 216-Z-9 crib, 200 West area, Department of Energy (DOE) Hanford Site, Washington by use of two-dimensional high resolution seismic reflection surveys and borehole geophysical data. The study makes use of recent advances in seismic reflection amplitude versus offset (AVO) technology to directly detect the presence of subsurface DNAPL. The techniques proposed are a noninvasive means towards site characterization and direct free-phase DNAPL detection. This report covers the results of Task 3 and change of scope of Tasks 4-6. Task 1 contains site evaluation and seismic modeling studies. The site evaluation consists of identifying and collecting preexisting geological and geophysical information regarding subsurface structure and the presence and quantity of DNAPL. The seismic modeling studies were undertaken to determine the likelihood that an AVO response exists and its probable manifestation. Task 2 is the design and acquisition of 2-D seismic reflection data designed to image areas of probable high concentration of DNAPL. Task 3 is the processing and interpretation of the 2-D data. Task 4, 5, and 6 were designing, acquiring, processing, and interpretation of a three dimensional seismic survey (3D) at the Z-9 crib area at 200 west area, Hanford

  12. Study of radiosensitization of chloroquine on esophageal cancer cell line

    International Nuclear Information System (INIS)

    Yuan Xiaoli; Li Tao; Huang Jianming; Zha Xiao; Deng Bifang; Lang Jinyi

    2014-01-01

    Objective: To investigate the possibility of chloroquine radiosensitization of esophageal cancer cell line TE-1 and its further mechanism. Methods: Effect of chloroquine on cell viability of TE-1 cells was determined by MTT method. Expression of LC3, Beclin-1 and formation of acidic vesicular organelles (AVOs) were determined by Western blot, and fluorescence staining with Lyso-Tracker Red DND-99, respectively. Clonogenic survival of TE-1 cells was examined by clonogenic forming assay. Results: Chloroquine showed dose-dependent inhibition of TE-1 cell growth, and its values of IC_5_0 and IC_1_0 were (72.33±5.28) and (15.42±3.33) μmol/L, respectively. The expression of Beclin-1 and LC3-II/I markedly increased in irradiated TE-1 cells. The addition of chloroquine with IC_1_0 concentration significantly reduced the fluorescence and intensity of AVOs accumulation in the cytoplasm of TE-1 cells. Clonogenic survival fraction decreased obviously in TE-1 cells with addition of chloroquine after radiation and the value of SERD0 was 1.439. Conclusions: Chloroquine could radiosensitize esophageal cancer cells by blocking autophagy-lysosomal pathway and be used as a potential radiosensitizing strategy. (authors)

  13. A new 28Si single crystal: counting the atoms for the new kilogram definition

    Science.gov (United States)

    Bartl, G.; Becker, P.; Beckhoff, B.; Bettin, H.; Beyer, E.; Borys, M.; Busch, I.; Cibik, L.; D'Agostino, G.; Darlatt, E.; Di Luzio, M.; Fujii, K.; Fujimoto, H.; Fujita, K.; Kolbe, M.; Krumrey, M.; Kuramoto, N.; Massa, E.; Mecke, M.; Mizushima, S.; Müller, M.; Narukawa, T.; Nicolaus, A.; Pramann, A.; Rauch, D.; Rienitz, O.; Sasso, C. P.; Stopic, A.; Stosch, R.; Waseda, A.; Wundrack, S.; Zhang, L.; Zhang, X. W.

    2017-10-01

    A new single crystal from isotopically enriched silicon was used to determine the Avogadro constant N A by the x-ray-crystal density method. The new crystal, named Si28-23Pr11, has a higher enrichment than the former ‘AVO28’ crystal allowing a smaller uncertainty of the molar mass determination. Again, two 1 kg spheres were manufactured from this crystal. The crystal and the spheres were measured with improved and new methods. One sphere, Si28kg01a, was measured at NMIJ and PTB with very consistent results. The other sphere, Si28kg01b, was measured only at PTB and yielded nearly the same Avogadro constant value. The mean result for both 1 kg spheres is N A  =  6.022 140 526(70)  ×  1023 mol-1 with a relative standard uncertainty of 1.2  ×  10-8. This value deviates from the Avogadro value published in 2015 for the AVO28 crystal by about 3.9(2.1)  ×  10-8. Possible reasons for this difference are discussed and additional measurements are proposed.

  14. Image quality and dose in mammographic images obtained in Mexico City hospitals

    International Nuclear Information System (INIS)

    Ruiz-Trejo, C.; Brandan, M.-E.; Verdejo, M.; Flores, A.; Guevara, M.; Martin, J.; Madero-Preciado, L.

    2001-01-01

    The performance of three mammographic systems in large Mexican hospitals has been evaluated, as well as the image quality and associated dose. Quality control tests include examination of X-ray equipment, darkroom conditions, film processor, and viewboxes. Systems referred to as '1', '2', and '3' passed 50%, 75% and 75% of these tests, respectively. Quality image is assessed using five images obtained under similar nominal conditions in each X-ray equipment. System 1 generates no image of acceptable quality, while equipment 2 and 3 produce one and two, respectively. The mean glandular dose for the best images obtained in each service with an accreditation phantom has been measured, and the values are 1.4 mGy, 1.6 mGy, and 1.0 mGy, respectively. (author)

  15. Guidelines for the physician's behaviour after exposure of embryos or fetuses to ionizing radiation or after incorporation of radioactive substances for medical purposes

    International Nuclear Information System (INIS)

    Leppin, W.

    1980-01-01

    These guidelines intend to give the physician information on his further actions if radiation has been used in pregnant women for diagnostic purposes, and especially on the medical advice to be given to the woman. The guidelines deal mainly with radiation exposures up to a dose of 20 mGy (2 rd). The guidelines are to show that there is no indication in this dose range for the necessity of an abortion. If doses have been higher than 20 mGy (2 rd), which may be the fact in only a few cases, careful and complex diagnostic efforts are required for the decision on an abortion. The guidelines give some information also on the dose range above 20 mGy (2 rd). (orig.) [de

  16. Radiation risk to the patient: a case study involving multiple diagnostic X ray exposures given over a period of 25 years

    International Nuclear Information System (INIS)

    Rainbow, A.J.; McMaster Univ., Hamilton, ON; Roginski, P.; McGeen, W.

    1992-01-01

    The cumulative somatic dose index (SDI) for a number of diagnostic X ray examinations was made for a 60 year old male. The history of diagnostic X ray exposure for this patient from 1957 to 1983 showed 29 diagnostic X ray examinations including more than 100 films and 15 minutes of fluoroscopy. The total cumulative SDI to this patient was 214 mGy (about 21 rad). More than half this dose, 142 mGy, was contributed from upper GI and barium enema examinations which used fluoroscopy, with 88 mGy from the fluoroscopy alone. Using the recently revised risk coefficient for fatal cancer following whole-body irradiation of adult workers recommended by the International Commission on Radiological Protection in 1990, the authors estimate a 0.9% cancer morality risk to this patient resulting from the 29 diagnostic X ray examinations. (author)

  17. Reference dose levels for dental periapical radiography in Chonnam Province

    International Nuclear Information System (INIS)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja; Lee, Jae Seo; Kim, Young Hee

    2009-01-01

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  18. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  19. Study of the radiated energy loss during massive gas injection mitigated disruptions on EAST

    Science.gov (United States)

    Duan, Y. M.; Hao, Z. K.; Hu, L. Q.; Wang, L.; Xu, P.; Xu, L. Q.; Zhuang, H. D.; EAST Team

    2015-08-01

    The MGI mitigated disruption experiments were carried out on EAST with a new fast gas controlling valve in 2012. Different amounts of noble gas He or mixed gas of 99% He + 1% Ar are injected into plasma in current flat-top phase and current ramp-down phase separately. The initial results of MGI experiments are described. The MGI system and the radiation measurement system are briefly introduced. The characteristics of radiation distribution and radiation energy loss are analyzed. About 50% of the stored thermal energy Wdia is dissipated by radiation during the entire disruption process and the impurities of C and Li from the PFC play important roles to radiative energy loss. The amount of the gas can affect the pre-TQ phase. Strong poloidal asymmetry of radiation begins to appear in the CQ phase, which is possibly caused by the plasma configuration changes as a result of VDE. No toroidal radiation asymmetry is observed presently.

  20. Reference dose levels for dental periapical radiography in Chonnam Province

    Energy Technology Data Exchange (ETDEWEB)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja [Department of Oral and Maxillofacial Radiology, College of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Lee, Jae Seo [Department of Oral and Maxillofacial Radiology, Chonnan National University Hospital, Gwangju (Korea, Republic of); Kim, Young Hee [Department of Oral and Maxillofacial Radiology, Hallym University Sacred Heart Hospital, Chuncheon (Korea, Republic of)

    2009-12-15

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  1. Dosimetry of beta particles using Li:Mg, Cu, P + Ptfe

    International Nuclear Information System (INIS)

    Olvera, L.; Azorin, J.; Rivera, T.

    2003-01-01

    This paper presents the experimental results of determining the thermoluminescence (Tl) response of LiF: Mg, Cu, P + Ptfe pellets excited with 90 Sr/ 90 Y beta radiation. The glow curve exhibited three peaks which appear at 121 C, 178 C and 217 C . Its relative sensitivity is 49 with respect to that of the TLD-100 dosemeter taken as a reference. The minimal dose that could be measured was 750 mGy. The Tl response as a function of dose was linear in the range of 0.7 mGy to 22.5 mGy. The study of the repeatability of the information contained in the pellets showed a standard deviation of 2 %. (Author)

  2. Materials Genome Initiative

    Science.gov (United States)

    Vickers, John

    2015-01-01

    The Materials Genome Initiative (MGI) project element is a cross-Center effort that is focused on the integration of computational tools to simulate manufacturing processes and materials behavior. These computational simulations will be utilized to gain understanding of processes and materials behavior to accelerate process development and certification to more efficiently integrate new materials in existing NASA projects and to lead to the design of new materials for improved performance. This NASA effort looks to collaborate with efforts at other government agencies and universities working under the national MGI. MGI plans to develop integrated computational/experimental/ processing methodologies for accelerating discovery and insertion of materials to satisfy NASA's unique mission demands. The challenges include validated design tools that incorporate materials properties, processes, and design requirements; and materials process control to rapidly mature emerging manufacturing methods and develop certified manufacturing processes

  3. Neuroimmune response and sleep studies after whole body irradiation with high-LET particles

    Science.gov (United States)

    Marquette, C.; Mathieu, J.; Bertho, J.-M.; Galonnier, M.; Wysoki, J.; Maubert, C.; Balanzat, E.; Gerbin, R.; Aigueperse, J.; Clarençon, D.

    2009-10-01

    In order to investigate the biological effects of galactic rays on astronaut cerebral functions after space flight, mice were exposed to different heavy ions (HZE) in whole-body conditions at doses comparable to the galactic flux: 12C, 16O and 20Ne (95 MeV/u, at 42-76 mGy). Animals were also exposed to 42 mGy of 60Co radiation for comparison with HZE. The neuroimmune response, evaluated by interleukin-1 (IL-1) measurement, showed that this cytokine was produced 3 h after irradiation by 16O or 60Co. In contrast, neither 12C (56.7 mGy) nor 20Ne (76 mGy) induced IL-1 production. However, immunohistochemical staining of 12C-irradiated mouse brain tissue showed 2 months later a marked inflammatory reaction in the hippocampus and a diffuse response in parenchyma. Sleep studies were realized before and after exposure to 42 mGy of 16O and 76 mGy of 20Ne: only the 20Ne radiation displayed a small effect. A slight decrease in paradoxical sleep, corresponding to a reduction in the number of episodes of paradoxical sleep, was manifested between 8 and 22 days after exposure. Exposure to 12C and 16O induced no changes either in cellularity of spleen or thymus, or in caspase 3 activity (as much as four months after irradiation). Taken together, these data indicate that the CNS could be sensitive to heavy ions and that responses to HZE impact depend on the nature of the particle, the dose threshold and the time delay to develop biological processes. Differences in responses to different HZE highlight the complex biological phenomena to which astronauts are submitted during space flight.

  4. Neuro-immune response and sleep studies after whole body irradiation with high-LET particles

    International Nuclear Information System (INIS)

    Marquette, C.; Bertho, J.M.; Wysoki, J.; Maubert, C.; Gerbin, R.; Aigueperse, J.; Mathieu, J.; Galonnier, M.; Clarencon, D.; Balanzat, E.

    2009-01-01

    In order to investigate the biological effects of galactic rays on astronaut cerebral functions after space flight, mice were exposed to different heavy ions (HZE) in whole-body conditions at doses comparable to the galactic flux: 12 C, 16 O and 20 Ne (95 MeV/u, at 42-76 mGy). Animals were also exposed to 42 mGy of 60 Co radiation for comparison with HZE. The neuro-immune response, evaluated by interleukin-I (IL-1) measurement, showed that this cytokine was produced 3 h after irradiation by 16 O or 60 Co. In contrast, neither 12 C (56.7 mGy) nor 20 Ne (76 mGy) induced IL-1 production. However, immunohistochemical staining of 12 C-irradiated mouse brain tissue showed 2 months later a marked inflammatory reaction in the hippocampus and a diffuse response in parenchyma. Sleep studies were realized before and after exposure to 42 mGy of 16 O and 76 mGy of 20 Ne: only the 20 Ne radiation displayed a small effect. A slight decrease in paradoxical sleep, corresponding to a reduction in the number of episodes of paradoxical sleep, was manifested between 8 and 22 days after exposure. Exposure to 12 C and 16 O induced no changes either in cellularity of spleen or thymus, or in caspase 3 activity (as much as four months after irradiation). Taken together, these data indicate that the CNS could be sensitive to heavy ions and that responses to HZE impact depend on the nature of the particle, the dose threshold and the time delay to develop biological processes. Differences in responses to different HZE highlight the complex biological phenomena to which astronauts are submitted during space flight. (authors)

  5. Use of the EC quality criteria as a common method of inspecting CT laboratories - A pilot project by the Nordic radiation protection authorities

    International Nuclear Information System (INIS)

    Torp, C.G.; Olerud, H.M.; Einarsson, G.; Groen, P.; Leitz, W.; Servomaa, A.

    2001-01-01

    In the frame of Nordic radiation protection co-operation, quality criteria for computed tomography (CT) as published by the European Commission were used for the evaluation of selected CT laboratories in each of the Nordic countries. The mean values for all five countries of the weighted CT dose index (CTDI w ) and dose length product (DLP) were 60 mGy and 740 mGy · cm for CT of the brain, 11 mGy and 420 mGy · cm for CT of the chest, and 40 mGy and 420 mGy · cm for CT of the lumbar spine, respectively. A comparison with the reference levels set in the above mentioned publication gives a diversified result: compliance for the DLP-values is generally achieved with good margins whereas the CTDI w -values were frequently larger for brain and lumbar spine examinations. The radiographic technique was generally also within the recommendations from the EC. Generally most of the image quality criteria were fulfilled, but it must be borne in mind that the study was biased in the way that two local radiologists in consensus evaluated their own images. Image material from only three patients was selected for each of the clinical indications, that means the project was not designed for ranking laboratories, but it is a way of making the departments aware of the need for optimisation regarding image quality and patient dose, and also of the problems associated with this task. During the study suggestions were brought forward concerning amendments of the quality criteria: some need a better definition, some are not relevant for the diagnostic task in question, some could be added. Instead of 'yes' and 'no', a range of maybe 5 levels of visualisation should be introduced in order to better characterize the level of diagnostic performance. (author)

  6. Pediatric CT dose reduction for suspected appendicitis: a practice quality improvement project using artificial Gaussian noise--part 1, computer simulations.

    Science.gov (United States)

    Callahan, Michael J; Kleinman, Patricia L; Strauss, Keith J; Bandos, Andriy; Taylor, George A; Tsai, Andy; Kleinman, Paul K

    2015-01-01

    The purpose of this study was to develop a departmental practice quality improvement project to systematically reduce CT doses for the evaluation of suspected pediatric appendicitis by introducing computer-generated gaussian noise. Two hundred MDCT abdominopelvic examinations of patients younger than 20 years performed with girth-based scanning parameters for suspected appendicitis were reviewed. Two judges selected 45 examinations in which the diagnosis of appendicitis was excluded (14, appendix not visualized; 31, normal appendix visualized). Gaussian noise was introduced into axial image series, creating five additional series acquired at 25-76% of the original dose. Two readers reviewed 270 image series for appendix visualization (4-point Likert scale and arrow localization). Volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) were calculated by use of patient girth. Confidence ratings and localization accuracy were analyzed with mixed models and nonparametric bootstrap analysis at a 0.05 significance level. The mean baseline SSDE for the 45 patients was 16 mGy (95% CI, 12-20 mGy), and the corresponding CTDIvol was 10 mGy (95% CI, 4-16 mGy). Changes in correct appendix localization frequencies were minor. There was no substantial trend with decreasing simulated dose level (p = 0.46). Confidence ratings decreased with increasing dose reduction (p = 0.007). The average decreases were -0.27 for the 25% simulated dose (p = 0.01), -0.17 for 33% (p = 0.03), and -0.03 for 43% (p = 0.65). Pediatric abdominal MDCT can be performed with 43% of the original dose (SSDE, 7 mGy; CTDIvol, 4.3 mGy) without substantially affecting visualization of a normal appendix.

  7. Assessment of mean glandular dose to patients from digital mammography systems

    International Nuclear Information System (INIS)

    Pwamang, Caroline K.

    2016-07-01

    Mean glandular dose assessment of patients undergoing digital mammography examination has been done. A total of 297 patient data was used for the study. Basic Quality Control tests were done to ascertain the performance of the equipment used. The results of Quality Control tests indicated that the three Mammography units used for this study were functioning within the internationally acceptable performance criteria. Patients with a breast thickness of 30 mm within the two age groups of 40-49 yrs and 50-64 yrs received doses slightly higher than the acceptable dose levels. A patient in the category 40-49 yrs with breast thickness of 30 mm received 1.83 mGy as calculated Mean Glandular Dose, 2.10 mGy was the recorded dose and 1.58 mGy was recorded under the age group 50-64 yrs. These values have deviated by -22%, -40%, and -5.33% respectively from 1.5 mGy which is the recommended dose for a breast thickness of 30 mm. Also patients with breast thickness of 70 mm under the age group 40–49 yrs had a recorded dose of 6.58 mGy, which deviated by -1.21% from the recommended value of 6.5 mGy for that breast thickness. Aside these values, all the other values were within the recommended dose values. The percentage deviation between the recommended values and the calculated values was within ±25% which was a working limit that was set for this work. Doses delivered by the Full-field Digital mammography equipment were higher than doses delivered by the Computered Radiography equipment. The calculated Mean Glandular Doses for the three facilities were within recommended dose values. (author)

  8. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    Directory of Open Access Journals (Sweden)

    Sina S

    2014-12-01

    Full Text Available Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti and GR-200 (LiF: Mg, Cu, P and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100.

  9. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Sina, S; Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M; Faghihi, R

    2014-01-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities

  10. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Sina, S [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M [Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of); Faghihi, R [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of)

    2014-06-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.

  11. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    Science.gov (United States)

    Sina, S; Zeinali, B; Karimipoorfard, M; Lotfalizadeh, F; Sadeghi, M; Zamani, E; Faghihi, R

    2014-01-01

    Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100. PMID:25599058

  12. SU-F-I-36: In-Utero Dose Measurements Within Postmortem Subjects for Estimating Fetal Doses in Pregnant Patients Examined with Pulmonary Embolism, Trauma, and Appendicitis CT

    Energy Technology Data Exchange (ETDEWEB)

    Lipnharski, I; Quails, N; Carranza, C; Correa, N; Bidari, S; Bickelhaup, M; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: The imaging of pregnant patients is medically necessary in certain clinical situations. The purpose of this work was to directly measure uterine doses in a cadaver scanned with CT protocols commonly performed on pregnant patients in order to estimate fetal dose and assess potential risk. Method: One postmortem subject was scanned on a 320-slice CT scanner with standard pulmonary embolism, trauma, and appendicitis protocols. All protocols were performed with the scan parameters and ranges currently used in clinical practice. Exams were performed both with and without iterative reconstruction to highlight the dose savings potential. Optically stimulated luminescent dosimeters (OSLDs) were inserted into the uterus in order to approximate fetal doses. Results: In the pulmonary embolism CT protocol, the uterus is outside of the primary beam, and the dose to the uterus was under 1 mGy. In the trauma and appendicitis protocols, the uterus is in the primary beam, the fetal dose estimates were 30.5 mGy for the trauma protocol, and 20.6 mGy for the appendicitis protocol. Iterative reconstruction reduced fetal doses by 30%, with uterine doses at 21.3 for the trauma and 14.3 mGy for the appendicitis protocol. Conclusion: Fetal doses were under 1 mGy when exposed to scatter radiation, and under 50 mGy when exposed to primary radiation with the trauma and appendicitis protocols. Consistent with the National Council on Radiation Protection & Measurements (NCRP) and the International Commission on Radiological Protection (ICRP), these doses exhibit a negligible risk to the fetus, with only a small increased risk of cancer. Still, CT scans are not recommended during pregnancy unless the benefits of the exam clearly outweigh the potential risk. Furthermore, when possible, pregnant patients should be examined on CT scanners equipped with iterative reconstruction in order to keep patient doses as low as reasonable achievable.

  13. Assessment of Regional Pediatric Computed Tomography Dose Indices in Tamil Nadu.

    Science.gov (United States)

    Saravanakumar, A; Vaideki, K; Govindarajan, K N; Jayakumar, S; Devanand, B

    2017-01-01

    The aim of this article is to assess Tamil Nadu pediatric computed tomography (CT) diagnostic reference levels (DRLs) by collecting radiation dose data for the most commonly performed CT examinations. This work was performed for thirty CT scanners installed in various parts of the Tamil Nadu region. The patient cohort was divided into two age groups: <1 year, and 1-5 years. CT dose indices were measured using a 10 cm 3 pencil ion chamber with pediatric head and body polymethyl methacrylate phantoms. Dose data such as volumetric CT dose index (CTDI v ) and dose length product (DLP) on a minimum of twenty average-sized pediatric patients in each category were recorded to calculate a mean site CTDI v and DLP value. The rounded 75 th percentile was used to calculate a pediatric DRL for each hospital, and then region by compiling all results. Data were collected for 3600 pediatric patients. Pediatric CT DRL for two age groups: <1 year (CTDI v and DLP of head [20 mGy, 352 mGy.cm], chest [7 mGy, 120 mGy.cm] and abdomen [12 mGy, 252 mGy.cm]), and 1-5 years (CTDI v and DLP of head [38 mGy, 505 mGy.cm], chest [8 mGy, 132 mGy.cm] and abdomen [14 mGy, 270 mGy.cm]) for select procedures have been calculated. Proposed pediatric DRLs of CTDI v and DLP for head procedure were lower, and for chest and abdomen procedures were higher than European pediatric DRLs for both age groups.

  14. Assessment of DNA double-strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterization.

    Science.gov (United States)

    Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M

    2016-01-01

    Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.

  15. The effects of γ-ray on charging behaviour using polyimide

    Science.gov (United States)

    Qin, Sichen; Tu, Youping; Tan, Tian; Wang, Shaohe; Yuan, Zhikang; Wang, Cong; Li, Laifeng; Wu, Zhixiong

    2018-06-01

    Insulation material is a key component of electrical equipment in satellites; its electrical properties determine the reliability and lifetime of the whole satellite. High-energy radioactive rays in space affect the molecular structure of the polymeric insulating materials. Under the action of plasma, high energy particles, along with the magnetic fields experienced in orbits, electric charges get injected into and trapped by the insulating material creating distortions in the electric field and even electrostatic discharges. Polyimides have been widely used for insulation in spacecraft. Choosing Co-60 gamma ray with irradiation doses of 1 MGy and 5 MGy to simulate the radiation environment of space, we investigated the effect of radiation on charging behaviour. The thermal stimulated current (TSC) from a high electric field over a wide range of temperatures was measured from which the activation energy was calculated. These results for the two sources show that the percentage increase in total charge was 133.3% and 119.4%. The γ, β 3, and α charge peaks of specimens after an irradiation dose of 1 MGy rose. In comparison, the β 2 peak of the 5 MGy-dosed specimens was enhanced. Also, there is almost no change in the γ, β 3, and α peaks. To understand the mechanism behind the TSC changes, the resulting physicochemical characteristics of an irradiated specimen were observed employing various analyses of chemical characteristics (x-ray photoelectron spectroscopy, differential scanning calorimetry and x-ray diffraction). Compared with the non-dosed specimen, the relative content of C–N and the glass transition temperature of the 1 MGy sample decreased, and the crystallinity increased, thus increasing the γ and α peak intensities. Compared with the 1 MGy sample, only the glass transition temperature had risen, thereby enhancing the β peak intensity. With the foregoing, a theoretical base for the selection and modification of insulation materials for

  16. Measurement of photo-neutron cross sections and isomeric yield ratios in the {sup 89}Y(γ,xn){sup 89-x}Y reactions at the bremsstrahlung end-point energies of 65, 70 and 75 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Tatari, Mansoureh [Yazd Univ. (Iran, Islamic Republic of). Physics Dept.; Naik, Haladhara [Bhabha Atomic Research Centre, Mumbai (India). Radiochemistry Div.; Kim, Guinyun; Kim, Kwangsoo [Kyungpook National Univ., Daegu (Korea, Republic of). Dept. of Physics; Shin, Sung-Gyun; Cho, Moo-Hyun [Pohang Univ. of Science and Technology (Korea, Republic of). Div. of Advanced Nuclear Engineering

    2017-07-01

    The flux-weighted average cross sections of the {sup 89}Y(γ,xn; x=1-4){sup 89-x}Y reactions and the isomeric yield ratios of the {sup 87m,g}Y, {sup 86m,g}Y, and {sup 85m,g}Y radionuclides produced in these reactions with the bremsstrahlung end-point energies of 65, 70 and 75 MeV have been determined by an activation and off-line γ-ray spectrometric technique using the 100 MeV electron linac in Pohang Accelerator Laboratory, Korea. The theoretical {sup 89}Y(γ,xn; x=1-4){sup 89-x}Y reaction cross sections for mono-energetic photons have been calculated using the computer code TALYS 1.6. Then the flux-weighted theoretical values were obtained to compare with the present data. The flux-weighted experimental and theoretical {sup 89}Y(γ,xn; x=1-4){sup 89-x}Y reaction cross sections increase very fast from the threshold values to a certain bremsstrahlung energy, where the other reaction channels open up. Thereafter it remains constant a while and then slowly decreases with the increase of cross sections for other reactions. Similarly, the isomeric yield ratios of {sup 87m,g}Y, {sup 86m,g}Y and {sup 85m,g}Y in the {sup 89}Y(γ,xn; x=2-4){sup 89-x}Y reactions from the present work and literature data show an increasing trend from their respective threshold values to a certain bremsstrahlung energy. After a certain point of energy, the isomeric yield ratios increase slowly with the bremsstrahlung energy. These observations indicate the role of excitation energy and its partitioning in different reaction channels.

  17. The biological effects of exposure to ionising radiation

    International Nuclear Information System (INIS)

    Higson, D.J.

    2016-01-01

    Scenarios for exposure to ionising radiation range from natural background radiation (chronic) to the explosions of atomic bombs (acute), with some medical, industrial and research exposures lying between these extremes. Biological responses to radiation that predominate at high doses incurred at high dose rates are different from those that predominate at low doses and low dose rates. Single doses from bomb explosions ranged up to many thousand mGy. Acute doses greater than about 1000 mGy cause acute radiation syndrome (ARS). Below this threshold, radiation has a variety of potential latent health effects: Change to the incidence of cancer is the most usual subject of attention but change to longevity may be the best overall measure because decreased incidences of non-cancer mortality have been observed to coincide with increased incidence of cancer mortality. Acute doses greater than 500 mGy cause increased risks of cancer and decreased life expectancy. For doses less than 100 mGy, beneficial overall health effects ('radiation hormesis') have been observed. At the other end of the spectrum, chronic exposure to natural radiation has occurred throughout evolution and is necessary for the normal life and health of current species. Dose rates greater than the present global average of about 2 mGy per year have either no discernible health effect or beneficial health effects up to several hundred mGy per year. It is clearly not credible that a single health effects model -- such as the linear no-threshold (LNT) model of risk estimation -- could fit all latent health effects. A more realistic model is suggested.

  18. Performance degradation of ferrofluidic feedthroughs in a mixed irradiation field

    Science.gov (United States)

    Simos, Nikolaos; Fernandes, S.; Mittig, Wolfgang; Pellemoine, Frederique; Avilov, M.; Kostin, M.; Mausner, L.; Ronningen, R.; Schein, M.; Bollen, G.

    2017-01-01

    Ferrofluidic feedthrough (FF) rotary seals containing either NdFeB or SmCo-type permanent magnets have been considered for use in the target and beam dump systems of the Facility for Rare Isotope Beams (FRIB). To evaluate their performance under irradiation three FF seals were irradiated in a mixed field consisting of fast neutrons, protons and γ-rays to an average absorbed dose of 0.2, 2.0, and 20.0 MGy at the Brookhaven Linac Isotope Producer facility (BLIP). The radiation types and energy profiles mimic those expected at the FRIB facility. Degradation of the operational performance of these devices due to irradiation is expected to be the result of the de-magnetization of the permanent magnets contained within the seal and the changes in the ferrofluid properties. Post-irradiation performance was evaluated by determining the ferrofluidic seal vacuum tightness and torque under static and dynamic conditions. The study revealed that the ferrofluidic feedthrough seal irradiated to a dose of 0.2 MGy maintained its vacuum tightness under both static and rotational condition while the one irradiated to a dose of 2.0 MGy exhibited signs of ferrofluid damage but no overall performance loss. At 20 MGy dose the effects of irradiation on the ferrofluid properties (viscosity and particle agglomeration) were shown to be severe. Furthermore, limited de-magnetization of the annular shaped Nd2Fe14B and Sm2Co17 magnets located within the irradiated FFs was observed for doses of 0.2 MGy and 20 MGy respectively.

  19. Effect of low dose radiation on expression of hematopoietic growth factors secreted by human mesenchymal stem cells from bone marrow

    International Nuclear Information System (INIS)

    Yang Yan; Wang Guanjun; Zhu Jingyan; Wang Juan

    2008-01-01

    Objective: To study the changes of hematopoietic growth factors secreted by human mesenchymal stem cells from bone marrow (BM-MSC) pretreated with low dose radiation (LDR). Methods: The cultured P4 and P5 BM-MSCs were exposed to X rays at the doses of 50, 75 and 100 mGy (dose rate 12.5 mGy·min -1 ). The changes of levels of stem cell factor (SCF), IL-6, macrophage colony-stimulating factor (M-CSF) secreted by BM- MSCs pretreated with LDR were determined by ELISA method. Results: As compared with control group at the same time, the levels of SCF in experimental group had a tendency of increasing after 24 h and 48 h radiation, but only in 75 mGy group the SCF level was obviously increased (P<0.05). The levels of IL-6 in 50 and 75 mGy groups at 24 h and 48 h, in 100 mGy group at 24 h were obviously increased compared with control group (P< 0.05). The levels of M-CSF in all the groups at 24 h, 48 h and 72 h except for the 50 mGy dose at 72 h were also increased (P<0.05), it increased markedly in 75 mGy dose group at 72 h. Conclusion: LDR has hormesis effect on BM-MSCs. After LDR, the BM-MSCs grow faster and in a certain phase the expression levels of hematopoietic growth factors are increased. (authors)

  20. Primary beam ionizing radiation for patients during coronary cineangiography

    International Nuclear Information System (INIS)

    Ramirez, Alfredo; Leyton, Fernando; Gamarra, Jorge; Oyarzun C, Carlos; Silva, Ana Maria; Ugalde, Hector; Dussaillant, Gaston

    2001-01-01

    Current cardiology practice incorporates hemodynamic and angiographic studies as normal procedures. Clinical actions have to be taken in interventionist cardiology that demand prolonged exposure times to radiation, which implies submitting patients to quantitatively significant doses. This work is a preliminary phase for clinical studies involving long procedures in hemodynamic and electrophysiological interventionist cardiology to show the magnitude of the radiation doses received by the patients after a proper diagnosis. The aim is to improve the patient's radiological protection as well as that of the staff involved. The study group consisted of 18 patients who underwent coronary angiography procedures with Siemens Angioskop D equipment and a Siemens Polidoros 80 generator. Four TLD Crystal detectors were used for the patient's dosimetry, which were located in the dorsal region along the left para scapular line, on the mid line of the thyroid region and a detector on the mid point between the umbilical zone and the pubis symphysis. For procedure times of 14±4.3 min., with fluoroscope times of 3.6±2.5 min., connection techniques of 87±15 kV. and 126±24 mA, the radiations recorded in the left inter scapular and right inter scapular regions were 215±199 mGy (1-710 mGy range) and 255±212 mGy ( 22 - 791mGy range ). The radiations in the pubic and thyroid regions were 0.23±0.07 mGy and 3.62±2.44 mGy, respectively (CO)

  1. Survey of pediatric MDCT radiation dose from university hospitals in Thailand. A preliminary for national dose survey

    Energy Technology Data Exchange (ETDEWEB)

    Kritsaneepaiboon, Supika [Dept. of Radiology, Faculty of Medicine, Prince of Songkla Univ., Hat Yai (Thailand)], e-mail: supikak@yahoo.com; Trinavarat, Panruethai [Dept. of Radiology, Faculty of Medicine, Chulalongkorn Univ., Bangkok (Thailand); Visrutaratna, Pannee [Dept. of Radiology, Faculty of Medicine, Chiang Mai Univ., Chiang Mai (Thailand)

    2012-09-15

    Background: Increasing pediatric CT usage worldwide needs the optimization of CT protocol examination. Although there are previous published dose reference level (DRL) values, the local DRLs should be established to guide for clinical practice and monitor the CT radiation. Purpose: To determine the multidetector CT (MDCT) radiation dose in children in three university hospitals in Thailand in four age groups using the CT dose index (CTDI) and dose length product (DLP). Material and Methods: A retrospective review of CT dosimetry in pediatric patients (<15 years of age) who had undergone head, chest, and abdominal MDCT in three major university hospitals in Thailand was performed. Volume CTDI (CTDIvol) and DLP were recorded, categorized into four age groups: <1 year, 1- < 5 years, 5- <10 years, and 10- <15 years in each scanner. Range, mean, and third quartile values were compared with the national reference dose levels for CT in pediatric patients from the UK and Switzerland according to International Commission on Radiological Protection (ICRP) recommendation. Results: Per age group, the third quartile values for brain, chest, and abdominal CTs were, respectively, in terms of CTDIvol: 25, 30, 40, and 45 mGy; 4.5, 5.7, 10, and 15.6 mGy; 8.5, 9, 14, and 17 mGy; and in terms of DLP: 400, 570, 610, and 800 mGy cm; 80, 140, 305, and 470 mGy cm; and 190, 275, 560,765 mGy cm. Conclusion: This preliminary national dose survey for pediatric CT in Thailand found that the majority of CTDIvol and DLP values in brain, chest, and abdominal CTs were still below the diagnostic reference levels (DRLs) from the UK and Switzerland regarding to ICRP recommendation.

  2. Evaluation of dose to tooth enamel from medical diagnostic X-ray examinations at Mayak PA

    Energy Technology Data Exchange (ETDEWEB)

    Wieser, A., E-mail: wieser@helmholtz-muenchen.de [Helmholtz Zentrum Muenchen - German Research Center for Environmental Health, Institute of Radiation Protection, D-85764 Neuherberg (Germany); Vasilenko, E. [Mayak Production Association, 456780 Ozyorsk (Russian Federation); Zankl, M.; Greiter, M.; Ulanovsky, A. [Helmholtz Zentrum Muenchen - German Research Center for Environmental Health, Institute of Radiation Protection, D-85764 Neuherberg (Germany); Sabayev, A.; Knyazev, V.; Zahrov, P. [Mayak Production Association, 456780 Ozyorsk (Russian Federation)

    2011-09-15

    The nuclear workers of the Mayak Production Association had regular check-ups including medical diagnostic X-ray examinations since start of the production lines in 1948. Doses from diagnostic examinations need to be considered in reconstruction of occupational doses of the workers with electron paramagnetic resonance (EPR) of tooth enamel. The numbers and types of examinations of an individual worker can be assessed from the Mayak PA archives but no information was available on doses delivered to teeth by a single specific examination. Of the twenty one applied examination procedures only three affected the teeth, these being X-ray examinations of teeth, skull and cervical spine. For these three kinds of examinations operational procedures and operating modes of X-ray units were compiled from the archive and photon spectra were obtained from a catalog of spectral data for diagnostic X-rays. Entrance doses in air kerma were calculated using the fluence of photon spectra and absorbed dose in tooth enamel for various tooth positions and exposure geometry was then calculated using dose conversion coefficients obtained from Monte Carlo simulations. Doses were calculated for examinations in 1948-2000. Except for examination of the skull, absorbed doses in enamel of incisors were found to be about twice as large as in enamel of molars. In the period before 1970 the largest mean absorbed doses in tooth enamel were due to X-ray examination of teeth, with 64 mGy and 34 mGy calculated for incisors and molars, respectively. In the same period the lowest mean doses were due to X-ray examination of the skull, with 11 mGy and 12 mGy calculated for incisors and molars, respectively. In the period from 1970 to 2000, largest mean doses in enamel were due to X-ray examination of cervical spine, with 23 mGy and 12 mGy calculated for incisors and molars, respectively.

  3. SU-E-J-11: Measurement of Eye Lens Dose for Varian On-Board Imaging with Different CBCT Acquisition Techniques

    International Nuclear Information System (INIS)

    Deshpande, S; Dhote, D; Kumar, R; Thakur, K

    2015-01-01

    Purpose: To measure actual patient eye lens dose for different cone beam computed tomography (CBCT) acquisition protocol of Varian’s On Board Imagining (OBI) system using Optically Stimulated Luminescence (OSL) dosimeter and study the eye lens dose with patient geometry and distance of isocenter to the eye lens Methods: OSL dosimeter was used to measure eye lens dose of patient. OSL dosimeter was placed on patient forehead center during CBCT image acquisition to measure eye lens dose. For three different cone beam acquisition protocol (standard dose head, low dose head and high quality head) of Varian On-Board Imaging, eye lens doses were measured. Measured doses were correlated with patient geometry and distance between isocenter to eye lens. Results: Measured eye lens dose for standard dose head was in the range of 1.8 mGy to 3.2 mGy, for high quality head protocol dose was in range of 4.5mGy to 9.9 mGy whereas for low dose head was in the range of 0.3mGy to 0.7mGy. Dose to eye lens is depends upon position of isocenter. For posterioraly located tumor eye lens dose is less. Conclusion: From measured doses it can be concluded that by proper selection of imagining protocol and frequency of imaging, it is possible to restrict the eye lens dose below the new limit set by ICRP. However, undoubted advantages of imaging system should be counter balanced by careful consideration of imaging protocol especially for very intense imaging sequences for Adoptive Radiotherapy or IMRT

  4. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  5. Intracellular magnesium concentrations in dogs with gastric dilatation-volvulus.

    Science.gov (United States)

    Bebchuk, T N; Hauptman, J G; Braselton, W E; Walshaw, R

    2000-11-01

    To quantify and compare intracellular magnesium concentrations (Mgi) in clinically normal dogs (control dogs) and dogs that have gastric dilatation-volvulus (GDV dogs) and to determine whether there is a difference in Mgi and serum magnesium concentrations (Mgs) between GDV dogs with and without cardiac arrhythmias. 41 control dogs and 21 GDV dogs. Rectus abdominis muscle specimens were obtained from control and GDV dogs for determination of Mgi. Blood samples were obtained from GDV dogs for determination of Mgs, and dogs were monitored for 48 hours for cardiac arrhythmias. Muscle specimens were frozen at -40 C, oven dried at 95 C, and digested with concentrated nitric acid. Multielemental analyses were performed by simultaneous/sequential inductively coupled plasma-atomic emission spectroscopy with fixed-cross flow nebulization. The Mg, was standardized to sulfur content to correct for the amount of fat and fascia in the muscle specimen. Mean (+/- SEM) values were recorded in parts per million (ppm). Results-There were no significant differences in Mgi between control (627 +/- 11.1 ppm) and GDV (597 +/- 20.5 ppm) dogs, in Mgi between GDV dogs with (590 +/- 34 ppm) and without (584 +/- 29 ppm) cardiac arrhythmias, and in Mgs between GDV dogs with (1.77 +/- 0.26 ppm) and without (1.51 +/- 0.09 ppm) cardiac arrhythmias. There was no correlation between Mgs and Mgi (R2 = 0.0001). Results indicate that Mg depletion is not pathophysiologically important in dogs with GDV and does not play a role in the cardiac arrhythmias detected in these patients.

  6. Survey of image quality and patient dose for computed tomography

    International Nuclear Information System (INIS)

    Augusto, Fernando Mecca

    2009-01-01

    The aim of this work is to evaluate the dose index and the image quality in seventeen computed tomography scanners installed in radiology departments at the city of Rio de Janeiro. The American College of Radiology (ACR) accreditation phantom (Gammex, 464) was used for the image quality evaluation. The following parameters were investigated according to the procedure manual of the ACR phantom: CT number calibration, exactitude of the slice thickness, low and high contrast resolution, uniformity, noise and artifacts. Despite of the CT number accuracy, only one scanner passed in the test. The low contrast resolution and the uniformity criteria were not accomplished in two different scanners. The conformity for the criteria established for slice width and high contrast was not verified in 16% and 11 % of the equipment respectively. The noise, expressed as a standard deviation measured in the center of the image in an adult abdomen protocol, ranged from 2.8 to 9.5. The ACR criteria of the accreditation program were not accomplished in the sample evaluated. Some parameters failed are essential to assure the diagnostic accuracy. For the head scans CTDI 100,VOL values varied between 9 and 109 mGy and the DLP from 160 to 2000 mGy cm for adults. Values for abdomen scans varied between 8 and 94 mGy and the DLP from 180 to 3700 mGy cm for adults, and CTDI 100,VOL from 3 to 54 mGy and DLP from 46 to 1300 mGy cm for children. Similar ranges were found for hi-resolution chest scans. These results are compatibles with those from reported literature and indicate a large potential for optimization and dose reduction, specially in pediatric patients. (author)

  7. Clinical application of low-dose spiral CT for orthodontics

    International Nuclear Information System (INIS)

    Xie Na; Gan Yungen; Shu Huang; Lin FeiFei; Li Zhiyong; Sun Jie

    2009-01-01

    Objective: To determine the effect of reducing the value of mA or kV on the image quality and the radiation dose of the patients undergoing low-dose spiral CT for orthodontics. Methods: Thirty patients were divided into three groups, each group has 10 patients. They were group 1 (80 kV and 200 mA), group 2 (120 kV and 80 mA), group 3 (120 kV and 200 mA) The volume CT dose index (CTDI) was recorded and the average dose-length produce (DLP) was calculated in three groups,respectively. Image quality of three groups were compared and scored by two radiologists, and the results were statistically analysed. Results: The CTDI and DLP of 80 kV group (group 2) were 8.7 mGy and (36.80 ± 3.60) mGy · cm, respectively, those of 80 mA group (group 3) were 19.6 mGy and (82.14 ± 7.18) mGy · cm, respectively, and those of conventional-dose group (group 1) were 19.6 mGy and (82.14 ± 7.18) mGy · cm, respectively. There was no significant difference among three groups in diagnostic image quality. Conclusions: Low-dose spiral CT for orthodontics, especially the low-kV scan, may decrease the radiation exposure and guarantee the image quality. (authors)

  8. SU-F-I-36: In-Utero Dose Measurements Within Postmortem Subjects for Estimating Fetal Doses in Pregnant Patients Examined with Pulmonary Embolism, Trauma, and Appendicitis CT

    International Nuclear Information System (INIS)

    Lipnharski, I; Quails, N; Carranza, C; Correa, N; Bidari, S; Bickelhaup, M; Rill, L; Arreola, M

    2016-01-01

    Purpose: The imaging of pregnant patients is medically necessary in certain clinical situations. The purpose of this work was to directly measure uterine doses in a cadaver scanned with CT protocols commonly performed on pregnant patients in order to estimate fetal dose and assess potential risk. Method: One postmortem subject was scanned on a 320-slice CT scanner with standard pulmonary embolism, trauma, and appendicitis protocols. All protocols were performed with the scan parameters and ranges currently used in clinical practice. Exams were performed both with and without iterative reconstruction to highlight the dose savings potential. Optically stimulated luminescent dosimeters (OSLDs) were inserted into the uterus in order to approximate fetal doses. Results: In the pulmonary embolism CT protocol, the uterus is outside of the primary beam, and the dose to the uterus was under 1 mGy. In the trauma and appendicitis protocols, the uterus is in the primary beam, the fetal dose estimates were 30.5 mGy for the trauma protocol, and 20.6 mGy for the appendicitis protocol. Iterative reconstruction reduced fetal doses by 30%, with uterine doses at 21.3 for the trauma and 14.3 mGy for the appendicitis protocol. Conclusion: Fetal doses were under 1 mGy when exposed to scatter radiation, and under 50 mGy when exposed to primary radiation with the trauma and appendicitis protocols. Consistent with the National Council on Radiation Protection & Measurements (NCRP) and the International Commission on Radiological Protection (ICRP), these doses exhibit a negligible risk to the fetus, with only a small increased risk of cancer. Still, CT scans are not recommended during pregnancy unless the benefits of the exam clearly outweigh the potential risk. Furthermore, when possible, pregnant patients should be examined on CT scanners equipped with iterative reconstruction in order to keep patient doses as low as reasonable achievable.

  9. Evaluation of glandular dose in conventional and digital mammography systems

    International Nuclear Information System (INIS)

    Coutinho, Celia Maria Campos

    2009-01-01

    A survey was conducted to estimate the average glandular dose (D g ) for patients undergoing mammography and to report the distribution of incident air kerma (K i ), patient age, compressed breast thickness and glandular tissue content. From 1183 cranio caudal mammograms clinical data were collected and doses were measured. The survey data included mammograms from six mammography equipment: two screen/film units (SFM), two computed radiography units (CR) and two full-field digital (DR). Mean value for patient age and compressed breast thickness were 57 +-12 y and 5.4 +-1.4 cm, respectively. To investigate the importance of technical characteristics of three different mammography systems and breast glandularity, K i and D g were measured for individual breast of 392 patients from the original sample with compressed breast thickness in the range of 5.5 cm to 6.5 cm using tissue-equivalent phantoms of different glandularities manufactured in this study to mimic both the attenuation and the density of breast tissues. Mean K i value was 10.0 +-3.6 mGy for SFM systems, 12.0 +-3.6 mGy for CR systems and 4.9 +-1.3 mGy for DR systems. Mean D g value was 1.4 +-0.5 mGy for S/F systems, 1.7 +-0.5 mGy for CR systems and 0.9 +-0.2 mGy for D R systems. Statistical analysis for differences in mean values of K i and D g between mammography systems showed significant effect of their technical characteristics (p i and D g , it was observed statistically significant differences between the group of patients with 0 to 50% glandularity and the group of patients with 50 to 100% glandularity. (author)

  10. Disruption mitigation experiment with massive gas injection of HT-7

    International Nuclear Information System (INIS)

    Zhuang Huidong; Zhang Xiaodong

    2013-01-01

    Massive gas injection (MGI) is a promising method on disruption mitigation. The working principle of the fast valve for disruption mitigation was introduced. The disruption mitigation experiments by MGI on HT-7 were described. The experiment shows that the impurities radiation is improved by injecting appropriate amount of gas, and the current quench rate is slow down, so the electromagnetic load on the device is mitigated. The experiments show that the fast valve can completely satisfy the requirement of disruption mitigation on HT-7. (authors)

  11. Analysis by Fourier Transform Infrared (FTIR) of the gamma radiation effect on epoxy resin, used as solidification agent of radioactive wastes

    International Nuclear Information System (INIS)

    Liu, C.H.; Riella, H.G.; Guedes, S.M.L.

    1995-01-01

    The effects of gamma radiation on Epoxy resin, used as solidification agent of radioactive wastes, were studied by Fourier Transform Infrared (FTIR). The spectra showed no significant modifications on Epoxy resin functional groups (irradiated with dose from 0 to 1 MGy). Up to 1 MGy Epoxy resin did not oxidize, confirming the Epoxy good radiation strength. The presence of aromatic chain and amine group, mainly tertiary amine, give good radiolytic stability to the Epoxy, increasing the interest to use this material in nuclear facilities. (author). 3 refs, 2 figs

  12. SU-E-P-08: Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight

    International Nuclear Information System (INIS)

    Wang, H; Wang, Y; Weng, H

    2015-01-01

    Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the local diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan

  13. Entrance surface dose measurements in pediatric radiological examinations

    International Nuclear Information System (INIS)

    Ribeiro, L.A.; Yoshimura, E.M.

    2008-01-01

    A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo, in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0.068 mGy (5-9 years old); 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100 mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20 mGy, respectively) are above the European reference levels (1.5 mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a

  14. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    International Nuclear Information System (INIS)

    Nawfel, RD; Young, G

    2016-01-01

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

  15. Average glandular dose in digital mammography and breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Olgar, T. [Ankara Univ. (Turkey). Dept. of Engineering Physics; Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Kahn, T.; Gosch, D. [Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2012-10-15

    Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT.

  16. Average glandular dose in digital mammography and breast tomosynthesis

    International Nuclear Information System (INIS)

    Olgar, T.; Universitaetsklinikum Leipzig AoeR; Kahn, T.; Gosch, D.

    2012-01-01

    Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT.

  17. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    International Nuclear Information System (INIS)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  18. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure.

    Science.gov (United States)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-05-01

    Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the

  19. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Joscha, E-mail: joscha.maier@dkfz.de [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Sawall, Stefan; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, University of Erlangen–Nürnberg, 91052 Erlangen (Germany)

    2014-05-15

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  20. Risk and benefit associated with preventive mammography examinations

    International Nuclear Information System (INIS)

    Vladar, M.; Nikodemova, D.

    1998-01-01

    The risk of mammographic examination was estimated. It is concluded that a mean glandular dose (MGD) of 1 mGy per exposure can be associated with a risk of 1 radiation-induced carcinoma per less than 100 positive detected by the preventive examination. The variability of actual MGD at various hospitals can be quite large. Although the majority of measurements were made on phantoms it is assumed that the national MGD average will exceed 3 mGy for the average breast size of 55 mm

  1. Dose levels in conventional X-rays

    International Nuclear Information System (INIS)

    Guerra M, J. A.; Gonzalez G, J. A.; Pinedo S, A.; Salas L, M. A.; Vega C, H. R.; Rivera M, T.; Azorin N, J.

    2009-10-01

    There were a series of measures in the General Hospital of Fresnillo in the X-ray Department in the areas of X-1 and X-2-ray rooms and in the neonatal intensive care unit 2, was determined the dose surface entry in eyes, thyroid and gonads for patients undergoing to X-ray study of chest Tele by thermoluminescent dosimetry. Five dosemeters were used in each one of the scans; so find the following dose ranges 20 + - 23 mGy to 350 + - 41 mGy. With the results obtained we can conclude that the procedures used and the equipment calibration is adequate. (Author)

  2. Computed Tomography (CT) radiation dose in children: A survey to propose regional diagnostic reference levels in Greater Accra-Ghana

    International Nuclear Information System (INIS)

    Addo, Patience

    2016-07-01

    The aim of this work was to assess the doses delivered to paediatric patients during computed tomography (CT) examinations of the head, chest and abdomen, and establishing regional diagnostic reference levels (RDRLs) for four age groups. The patient data, technique parameters and dose descriptors collected include: age, sex, tube voltage, tube current, rotation time, slice thickness, scan length, volume CT dose index (CTDI_v_o_l) and dose length product (DLP). Currently, paediatric CT examinations account for 11% of radiation exposure. For the paediatric age groups; < 1 year, (1-5 years), (6-10 years) and (11-15 years), the proposed RDRLs for head in terms of CTDI_v_o_l are (28, 38, 48 and 86 mGy) and in terms of DLP; (395, 487, 601, 1614 mGy cm) respectively. For Chest examinations, proposed RDRLs in terms of CTDI_v_o_l are (1 and 5 mGy) and in terms of DLP; (18 and 110 mGy cm) for age groups; < 1 year and (1-5 years) respectively. For Abdomino-pelvic examinations, proposed RDRLs in terms of CTDI_v_o_l are (3, 3 and 10 mGy) and in terms of DLP; (71, 120 and 494 mGy cm) for age groups; < 1 year, (1-5 years) and (6-10 years) respectively. For abdomen examinations, proposed RDRLs in terms of CTDI_v_o_l are (3, 5 and 5 mGy) and in terms of DLP; (83, 124 and 233 mGy cm) for age groups; < 1 year, (1-5 years) and (11-15 years) respectively. RDRLs have been proposed for CTDI_v_o_l and DLP for head, chest, abdomen and Abdomino-pelvic paediatric CT examinations in this study. An optimisation is required for 11-15 years age group for the DLP values which was higher than their corresponding international DRLs. For an effective optimization of patient protection a trade-off between image quality and patients doses studies should be investigated. (au)

  3. Anti-tumor effect of low dose radiation in mice

    International Nuclear Information System (INIS)

    Fan Zhengping; Lu Jiaben; Zhu Bingchai

    1997-01-01

    The author reports the effects of the total body irradiation of low dose radiation (LDR) and/or the local irradiation of large dose on average tumor weights and tumor inhibitory rates in 170 mice inoculated S 180 sarcoma cell, and the influence of LDR on average longevity in 40 tumor-bearing animals. Results show (1) LDR in the range of 75∼250 mGy can inhibit tumor growth to some extent; (2) fractionated irradiation of 75 mGy and local irradiation of 10 Gy may produce a synergism in tumor growth inhibition; and (3)LDR may enhance average longevity in ascitic tumor-bearing mice

  4. Thermogravimetric study of γ-irradiated lanthanum oxalate

    International Nuclear Information System (INIS)

    Nayak, H.; Bhatta, D.

    2000-01-01

    Thermogravimetric study of La 2 (C 2 O 4 ) 3 , exposed to different doses (5.0 - 50.0 x 10 -2 MGy) of γ-rays has been carried out. Marginal effect is observed at lower doses which is prominent at higher dose (5.0 x 10 -1 MGy). The radiolytic damaged entities, generated by irradiation favours the reaction by creating new potential nucleation centres in the lattice. The solid product, La 2 O 3 formed by irradiation also acts as a heterogeneous catalyst and brings out changes in the reactivity of the solid. (author)

  5. SU-E-P-08: Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H; Wang, Y; Weng, H [Chiayi Chang Gung Memorial Hospital of The C.G.M.F, Puzi City, Chiayi County, Taiwan (China)

    2015-06-15

    Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the local diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan.

  6. Summary of round robin measurements of radiation induced conductivity in Wesgo AL995 alumina

    Energy Technology Data Exchange (ETDEWEB)

    Zinkle, S.J. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    This existing data on radiation induced conductivity (RIC) measurements performed on the same heat of the IEA reference ceramic insulator are summarized. Six different sets of RIC measurements have been performed on Wesgo AL995 at dose rates between 10 Gy/s and 1 MGy/s. In general, good agreement was obtained between the different groups of researchers. The data indicate that the RIC at a test temperature of 400-500{degrees}C is approximately linear with ionizing dose rate up to {approximately}1000 Gy/s, and exhibits an approximately square root dependence on dose rate between 1 kGy/s and 1 MGy/s.

  7. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    Energy Technology Data Exchange (ETDEWEB)

    Nawfel, RD; Young, G [Brigham & Women’s Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

  8. Patient dosimetry during chest radiography

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Kosutic, D.; Markovic, S.

    2004-01-01

    Reasons for the variation in patient doses from chest radiography procedure were investigated by assessing entrance skin doses from kerma-area product measurements. Data were collected from seven x-ray tubes in five hospitals involving 259 adult patients. The third quartile value was 0.81 mGy compared to general reference level of 0.30 mGy. The applied tube potential was main contributor to patient dose variation. If department use at least 90 k Vp, the mean entrance surface dose would be reduced ut to factor six. Modification of departmental procedure is correct approach for dose reduction in diagnostic radiology. (author) [sr

  9. Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Sic; Park, Ju Kyeong; Lee, Seung Hun; Kim, Yang Su; Lee, Sun Young; Cha, Seok Yong [Dept. of Radiation Oncology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2014-12-15

    To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11-30% reduction effect and the surface dose of thyroid showed 20-48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

  10. Optimization of the Radiological Protection of Patients in Diagnostic Radiology Department at Kenyatta National Hospital in Kenya

    International Nuclear Information System (INIS)

    Korir, G.K.; Ochieng, B.O.M; Wambani, J. S.

    2008-01-01

    The use of ionizing radiation in the medical field accounts for the largest contribution of radiation exposure to man. Use of ionizing radiation requires a careful balance of risks and benefits due to the somatic and hereditary which are well known to have no threshold level due to the random nature of radiation. The radiation doses received by patients undergoing radiographic examinations were measured in 189 randomly selected patients from three different x-ray rooms at a referral, teaching and research hospital in Kenya. The exercise was done on 54 pediatric and 135 adult patients during the screening period between October and November 2005. The entrance surface dose (ESD) to the patients undergoing each of these procedures was measured using LiF-100 thermoluminescent dosimeters (TLDs). The values obtained ranged from 0.33 mGy to 143 mGy for adult patients and 0.12 mGy to 4.32 mGy for pediatric patients. The mean values were found to be 8.44 mGy, 11.16 mGy and 1.44 mGy for rooms A, B and C respectively. The hospital's average dose stood at 7.01 mGy. The mean patient thickness for adults in cm were 19.5 for chest PA/AP, 28 chest LAT, 27 lumbar sacral, 28 lumbar spine AP, 30 lumbar spine LAT and for children 9.5 chest AP, 19.5 chest LAT, 8 post nasal space (PNS) 11.5 lumbar spine AP and 15 for lumbar spine LAT. Adult ages averaged at 35 years and less than 15 years old for sensitive to gamma rathe ESD in most procedures in adults were found to exceed the International ESD reference levels. However, it should be noted that so far guidance levels (GL) for children do not exist. The x-ray units were tested for quality control performance. They failed with respect to kVp accuracy, focal spot size and total filtration tests. From the Radiologists image quality assessment of the radiographs, 52% were awarded grade A, 40% grade B and 8% grade C. Film rejection analysis was measured to be 14% in overall. The following were the major causes; positioning, underexposure and

  11. DNA alterations and effects on growth and reproduction in Daphnia magna during chronic exposure to gamma radiation over three successive generations

    Energy Technology Data Exchange (ETDEWEB)

    Parisot, Florian [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-ENV/SERIS/LECO, Cadarache, St Paul-lez-Durance 13115 (France); Bourdineaud, Jean-Paul [UMR 5805 EPOC – OASU, Station marine d’Arcachon, Université Bordeaux 1, Arcachon 33120 (France); Plaire, Delphine; Adam-Guillermin, Christelle [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-ENV/SERIS/LECO, Cadarache, St Paul-lez-Durance 13115 (France); Alonzo, Frédéric, E-mail: frederic.alonzo@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-ENV/SERIS/LECO, Cadarache, St Paul-lez-Durance 13115 (France)

    2015-06-15

    Highlights: • We exposed three successive generations of Daphnia magna to chronic gamma radiation. • We examined DNA alterations and effects on survival, growth and reproduction. • DNA alterations were accumulated over a generation and transmitted to the progeny. • Effects on survival and reproduction, and delay in growth increased over generations. - Abstract: This study examined chronic effects of external Cs-137 gamma radiation on Daphnia magna exposed over three successive generations (F0, F1 and F2) to environmentally relevant dose rates (ranging from 0.007 to 35.4 mGy h{sup −1}). Investigated endpoints included survival, growth, reproduction and DNA alterations quantified using random-amplified polymorphic DNA polymerase chain reaction (RAPD-PCR). Results demonstrated that radiation effects on survival, growth and reproduction increased in severity from generation F0 to generation F2. Mortality after 21 days at 35.4 mGy h{sup −1} increased from 20% in F0 to 30% in F2. Growth was affected by a slight reduction in maximum length at 35.4 mGy h{sup −1} in F0 and by reductions of 5 and 13% in growth rate, respectively, at 4.70 and 35.4 mGy h{sup −1} in F2. Reproduction was affected by a reduction of 19% in 21 day-fecundity at 35.4 mGy h{sup −1} in F0 and by a delay of 1.9 days in brood release as low as 0.070 mGy h{sup −1} in F2. In parallel, DNA alterations became significant at decreasing dose rates over the course of F0 (from 4.70 mGy h{sup −1} at hatching to 0.007 mGy h{sup −1} after ∼21 days) and from F0 to F2 (0.070 mGy h{sup −1} at hatching to 0.007 mGy h{sup −1} after ∼21 days), demonstrating their rapid accumulation in F0 daphnids and their transmission to offspring generations. Transiently more efficient DNA repair leading to some recovery at the organism level was suggested in F1, with no effect on survival, a slight reduction of 12% in 21 day-fecundity at 35.4 mGy h{sup −1} and DNA alterations significant at highest

  12. Application of a Hybrid Detection and Location Scheme to Volcanic Systems

    Science.gov (United States)

    Thurber, C. H.; Lanza, F.; Roecker, S. W.

    2017-12-01

    We are using a hybrid method for automated detection and onset estimation, called REST, that combines a modified version of the nearest-neighbor similarity scheme of Rawles and Thurber (2015; RT15) with the regression approach of Kushnir et al. (1990; K90). This approach incorporates some of the windowing ideas proposed by RT15 into the regression techniques described in K90. The K90 and RT15 algorithms both define an onset as that sample where a segment of noise at earlier times is most "unlike" a segment of data at later times; the main difference between the approaches is how one defines "likeness." Hence, it is fairly straightforward to adapt the RT15 ideas to a K90 approach. We also incorporated the running mean normalization scheme of Bensen et al. (2007), used in ambient noise pre-processing, to reduce the effects of coherent signals (such as earthquakes) in defining noise segments. This is especially useful for aftershock sequences, when the persistent high amplitudes due to many earthquakes biases the true noise level. We use the fall-off of the K90 estimation function to assign uncertainties and the asymmetry of the function as a causality constraint. The detection and onset estimation stage is followed by iterative pick association and event location using a grid-search method. Some fine-tuning of some parameters is generally required for optimal results. We present 2 applications of this scheme to data from volcanic systems: Makushin volcano, Alaska, and Laguna del Maule (LdM), Chile. In both cases, there are permanent seismic networks, operated by the Alaska Volcano Observatory (AVO) and Observatorio Volcanológico de Los Andes del Sur (OVDAS), respectively, and temporary seismic arrays were deployed for a year or more. For Makushin, we have analyzed a year of data, from summer 2015 to summer 2016. The AVO catalog has 691 events in our study volume; REST processing yields 1784 more events. After quality control, the event numbers are 151 AVO events and

  13. Seismic Evaluation of Hydrocarbon Saturation in Deep-Water Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Michael Batzle

    2006-04-30

    During this last period of the ''Seismic Evaluation of Hydrocarbon Saturation in Deep-Water Reservoirs'' project (Grant/Cooperative Agreement DE-FC26-02NT15342), we finalized integration of rock physics, well log analysis, seismic processing, and forward modeling techniques. Most of the last quarter was spent combining the results from the principal investigators and come to some final conclusions about the project. Also much of the effort was directed towards technology transfer through the Direct Hydrocarbon Indicators mini-symposium at UH and through publications. As a result we have: (1) Tested a new method to directly invert reservoir properties, water saturation, Sw, and porosity from seismic AVO attributes; (2) Constrained the seismic response based on fluid and rock property correlations; (3) Reprocessed seismic data from Ursa field; (4) Compared thin layer property distributions and averaging on AVO response; (5) Related pressures and sorting effects on porosity and their influence on DHI's; (6) Examined and compared gas saturation effects for deep and shallow reservoirs; (7) Performed forward modeling using geobodies from deepwater outcrops; (8) Documented velocities for deepwater sediments; (9) Continued incorporating outcrop descriptive models in seismic forward models; (10) Held an open DHI symposium to present the final results of the project; (11) Relations between Sw, porosity, and AVO attributes; (12) Models of Complex, Layered Reservoirs; and (14) Technology transfer Several factors can contribute to limit our ability to extract accurate hydrocarbon saturations in deep water environments. Rock and fluid properties are one factor, since, for example, hydrocarbon properties will be considerably different with great depths (high pressure) when compared to shallow properties. Significant over pressure, on the other hand will make the rocks behave as if they were shallower. In addition to the physical properties, the scale and

  14. Alaska - Russian Far East connection in volcano research and monitoring

    Science.gov (United States)

    Izbekov, P. E.; Eichelberger, J. C.; Gordeev, E.; Neal, C. A.; Chebrov, V. N.; Girina, O. A.; Demyanchuk, Y. V.; Rybin, A. V.

    2012-12-01

    The Kurile-Kamchatka-Alaska portion of the Pacific Rim of Fire spans for nearly 5400 km. It includes more than 80 active volcanoes and averages 4-6 eruptions per year. Resulting ash clouds travel for hundreds to thousands of kilometers defying political borders. To mitigate volcano hazard to aviation and local communities, the Alaska Volcano Observatory (AVO) and the Institute of Volcanology and Seismology (IVS), in partnership with the Kamchatkan Branch of the Geophysical Survey of the Russian Academy of Sciences (KBGS), have established a collaborative program with three integrated components: (1) volcano monitoring with rapid information exchange, (2) cooperation in research projects at active volcanoes, and (3) volcanological field schools for students and young scientists. Cooperation in volcano monitoring includes dissemination of daily information on the state of volcanic activity in neighboring regions, satellite and visual data exchange, as well as sharing expertise and technologies between AVO and the Kamchatkan Volcanic Eruption Response Team (KVERT) and Sakhalin Volcanic Eruption Response Team (SVERT). Collaboration in scientific research is best illustrated by involvement of AVO, IVS, and KBGS faculty and graduate students in mutual international studies. One of the most recent examples is the NSF-funded Partnerships for International Research and Education (PIRE)-Kamchatka project focusing on multi-disciplinary study of Bezymianny volcano in Kamchatka. This international project is one of many that have been initiated as a direct result of a bi-annual series of meetings known as Japan-Kamchatka-Alaska Subduction Processes (JKASP) workshops that we organize together with colleagues from Hokkaido University, Japan. The most recent JKASP meeting was held in August 2011 in Petropavlovsk-Kamchatsky and brought together more than 130 scientists and students from Russia, Japan, and the United States. The key educational component of our collaborative program

  15. Exploring the Digital Universe with Europe's Astrophysical Virtual Observatory

    Science.gov (United States)

    2001-12-01

    Vast Databanks at the Astronomers' Fingertips Summary A new European initiative called the Astrophysical Virtual Observatory (AVO) is being launched to provide astronomers with a breathtaking potential for new discoveries. It will enable them to seamlessly combine the data from both ground- and space-based telescopes which are making observations of the Universe across the whole range of wavelengths - from high-energy gamma rays through the ultraviolet and visible to the infrared and radio. The aim of the Astrophysical Virtual Observatory (AVO) project, which started on 15 November 2001, is to allow astronomers instant access to the vast databanks now being built up by the world's observatories and which are forming what is, in effect, a "digital sky" . Using the AVO, astronomers will, for example, be able to retrieve the elusive traces of the passage of an asteroid as it passes near the Earth and so enable them to predict its future path and perhaps warn of a possible impact. When a giant star comes to the end of its life in a cataclysmic explosion called a supernova, they will be able to access the digital sky and pinpoint the star shortly before it exploded so adding invaluable data to the study of the evolution of stars. Background information on the Astrophysical Virtual Observatory is available in the Appendix. PR Photo 34a/01 : The Astrophysical Virtual Observatory - an artist's impression. The rapidly accumulating database ESO PR Photo 34a/01 ESO PR Photo 34a/01 [Preview - JPEG: 400 x 345 pix - 90k] [Normal - JPEG: 800 x 689 pix - 656k] [Hi-Res - JPEG: 3000 x 2582 pix - 4.3M] ESO PR Photo 34a/01 shows an artist's impression of the Astrophysical Virtual Observatory . Modern observatories observe the sky continuously and data accumulates remorselessly in the digital archives. The growth rate is impressive and many hundreds of terabytes of data - corresponding to many thousands of billions of pixels - are already available to scientists. The real sky is being

  16. A cytogenetic study on persons exposed to 241Am-Be neutron source

    International Nuclear Information System (INIS)

    Bai Yushu; Zhang Xiuxia; Guan Shurong; Xie Feng; Lu Meiying

    1988-01-01

    An 241 Am-Be neutron source of 120 millicrocurie was stolen by a boy on April the 3rd, 1982. He brought it to his home. The neutron source was broken and the radioactive substance contaminated the whole family. He and his other family members did not leave the contaminated environment for 70 days. There were altogether 14 persons exposed to the radioactive substances. Chromosome aberrations of peripheral blood lymphocytes of six exposed cases were analysed on an early day of June 1982. The exposure doses were estimated by the frequency of chromosome aberration. Biological dose absorbed by the boy who stole the source was about 96 ∼ 128 mGy (physical dose about 120 mGy), the others were about 10 ∼ 30 mGy (physical dose about 10 ∼ 30 mGy). The results indicated that biological dose were quite approximate to the physical doses. One and half years after the accident, the analysis of stable chromosome aberrations for 14 exposed persons showed that the frequencies of chromosome aberrations of the irradiated individuals were still higher than those of the controls. The differences between them are very significant

  17. Evaluation of doses in conventional radiology in the cities of Rio de Janeiro e Recife, Brazil

    International Nuclear Information System (INIS)

    Azevedo, Ana Cecilia P.; Osibote, Adelaja O.; Khoury, Helen J.

    2005-01-01

    This work is part of a program of evaluating doses in patients developed in several hospitals in the States of Rio de Janeiro and Pernambuco. We used the program DoseCal to evaluate the Input Skin Dose (DEP) and the Effective Dose (DE) in big public hospitals in the cities of Rio de Janeiro and Recife. It were included in the survey the doses of chest radiographs, cervical spine, lumbar spine, skull and pelvis in the projections AP, PA and LAT. To chest in PA the average value of DEP for the hospital A was 0.19 mGy. For to hospital B was 0.07 mGy. For the exam of the skull in PA the average value in A was 3.25 mGy and B of 0.49 mGy. With respect to radiological techniques might be noted that in most cases the hospital A used kilovoltage lower than in B and miliamperes higher. This can be one of the explanations for the difference of the values found for DEP and DE. The results showed significant discrepancies in values of doses as radiographic techniques when compared to the requirements established by the European Community for X-rays with image quality. This result is due to several factors: filtration, radiographic technique, professional technical experience and performance of radiographic equipment

  18. Crystal growth and thermoluminescence response of NaZr{sub 2}(PO{sub 4}){sub 3} at high gamma radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Ordóñez-Regil, E., E-mail: eduardo.ordonez@inin.gob.mx [Depto. de Química, Gerencia de Ciencias Básicas, Instituto Nacional de Investigaciones Nucleares, AP 18-1027, CP 11801 México D.F. (Mexico); Contreras-Ramírez, A., E-mail: aida.contreras@inin.gob.mx [Depto. de Química, Gerencia de Ciencias Básicas, Instituto Nacional de Investigaciones Nucleares, AP 18-1027, CP 11801 México D.F. (Mexico); Depto. de Tecnología de Materiales, Gerencia de Ciencias Aplicadas, Instituto Nacional de Investigaciones Nucleares, AP 18-1027, CP 11801 México D.F. (Mexico); Facultad de Ciencias, Universidad Autónoma del Estado de México, Unidad Académica el Cerrillo, Piedras Blancas, AP 2-139, CP 50000 Toluca Estado de México (Mexico); Fernández-Valverde, S.M., E-mail: suilma.fernandez@inin.gob.mx [Depto. de Química, Gerencia de Ciencias Básicas, Instituto Nacional de Investigaciones Nucleares, AP 18-1027, CP 11801 México D.F. (Mexico); González-Martínez, P.R., E-mail: pedro.gonzalez@inin.gob.mx [Depto. de Física, Gerencia de Ciencias Básicas, Instituto Nacional de Investigaciones Nucleares, AP 18-1027, CP 11801 México D.F. (Mexico); Carrasco-Ábrego, H., E-mail: hector.carrasco@inin.gob.mx [Depto. Aceleradores, Gerencia de Ciencias Ambientales, Instituto Nacional de Investigaciones Nucleares, AP 18-1027, CP 11801 México D.F. (Mexico)

    2013-11-15

    Graphical abstract: -- Highlights: •NaZr{sub 2}(PO{sub 4}){sub 3} exposed to gamma doses of 10, 30 and 50 MGy. •Gamma radiation produced growth of the crystal size of the NZP. •Morphology changes were reversible by heating. •Linear relationship between the thermoluminescence and the applied gamma dose. •This property could be useful for high-level gamma dosimetry. -- Abstract: This work describes the synthesis and characterization of NaZr{sub 2}(PO{sub 4}){sub 3}. The stability of this material under high doses of gamma radiation was investigated in the range of 10–50 MGy. Samples of unaltered and gamma irradiated NaZr{sub 2}(PO{sub 4}){sub 3} were characterized by X-ray diffraction, infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, and thermoluminescence. The results showed that while functional groups were not affected by the gamma irradiation, morphology changes were observed with increasing doses of gamma irradiation. The morphology of the non-irradiated compound is agglomerated flakes; however, irradiation at 10 MGy splits the flakes inducing the formation of well-defined cubes. Gamma irradiation induced the crystal size of the NaZr{sub 2}(PO{sub 4}){sub 3} to grow. The heat treatment (973 K) of samples irradiated at 50 MGy resulted in the recovery of the original morphology. Furthermore, the thermoluminescence analysis of the irradiated compound is reported.

  19. Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Sulieman, A.; Elzaki, M. [Sudan University of Science and Technology, College of Medical Radiologic Science, P. O. Box 1908, Khartoum 11111 (Sudan); Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Abuzaid, M. [University of Sharjah, College of Health Sciences, Medical Diagnostic Imaging Department, Sharjah (United Arab Emirates); Dalton, A.; Bradley, D., E-mail: Abdelmoneim_a@yahoo.com [University of Surrey, Centre for Nuclear and Radiation Physics, Department of Physics, GU2-7XH, Guildford, Surrey (United Kingdom)

    2015-10-15

    Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive technique that has been used for over 30 years in the diagnosis and management of pancreaticobiliary disorders. The objectives of this study were to evaluate the patient entrance surface air kerma doses (ESAK) and estimate the organ and effective doses during ERCP in three hospitals in Khartoum. A total of 55 patients were examined in three hospitals in Khartoum state, Sudan. Calibrated thermoluminescence dosimeters (TLD)-Gr-200-A)) were used to measure patients ESAK. The overall mean of ESAK for all ERCP procedures was 42.4 mGy. The mean patient ESAK in Fedail, Soba and Ibn sena centers were 26.7 mGy, 26.0 mGy, 72.4 mGy, respectively. The effective doses in three centers were 1.6, 1.56 and 2.67 mSv in that order and the overall mean effective dose was 2.01 mSv. Patient radiation doses vary widely among the different hospitals. Patient ESAK is low compared to previous studies in the light of the current practice. Patient dose was decreased significantly in the last two decades. (Author)

  20. Enhancing anaerobic treatment of wastewaters containing oleic acid

    NARCIS (Netherlands)

    Hwu, C.S.

    1997-01-01

    INTRODUCTION

    Lipids are one of the major organic pollutants in municipal and industrial wastewaters. Although domestic sewage typically contains about 40-100 mg/I lipids (Forster, 1992; Quéméneur and Marty, 1994), it is industrial wastewaters that are of greater

  1. Non-LTE profiles of strong solar lines

    Science.gov (United States)

    Schneeberger, T. J.; Beebe, H. A.

    1976-01-01

    The complete linearization method is applied to the formation of strong lines in the solar atmosphere. Transitions in Na(I), Mg(I), Ca(I), Mg(II), and Ca(II) are computed with a standard atmosphere and microturbulent velocity model. The computed profiles are compared to observations at disk center.

  2. Study of an optimization protocol for radiographic techniques in computerized radiology; Estudo de um protocolo de otimizacao para as tecnicas radiograficas em radiologia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Abrantes, Marcos Eugenio Silva

    2015-07-01

    This work is designed to produce information for the improvement of image quality to deployment in a radiology department based on previous reviews of the images by questionnaires of acceptance and quality e recognition of the parameters used in chest radiographic techniques. The data collected were divided by male, female, PA and LAT thickness, body mass index, biotypes, anthropomorphic parameters and body evaluation associated with constant voltage and the additional filtration. The results show the predominance of 35 and 40 constants with additional filtration from 0.5 to 1.5 mmAl, voltage in male: (PA and LAT) 86-92 kV and 96-112 kV, female: 85-98 kV and 96-112 kV. The charge applied to the tube for males: (PA and LAT) 5-10 mA.s and 5-16 mA.s, female: (PA and LAT) 6.3-8 mA.s and 9-14 mA.s. Absorbed doses for males: (PA and PF) 0.04-0.17 mGy and 0.03-0.19 mGy and from female (PA and PF) from 0.03-0.22 mGy and 0, 04-0.17 mGy. This procedure can be used in radiology department to implement and acceptance in the quality of images. (author)

  3. Radiation dose estimation by tooth enamel EPR dosimetry for residents of Dolon and Bodene

    International Nuclear Information System (INIS)

    Zhumadilov, Kassym; Ivannikov, Alexander; Apsalikov, Kazbek N.

    2006-01-01

    The method of electron paramagnetic resonance (EPR) dosimetry was applied to the enamel of the teeth extracted from the residents of the Dolon and Bodene settlements of the Beskaragay district, which is the area adjacent to the radioactive fallout of the most contaminating nuclear test of 1949. The individual accidental radiation doses due to the fallout were obtained from the amplitude of the radiation induced EPR signal from the CO 2- radical using the calibration method, after determining the parameters of EPR measurements to obtain the best reproducibility of the signal intensities. It was shown that after subtracting the natural background dose from the total absorbed dose obtained by EPR the residents of Dolon and Bodene received accidental radiation doses up to 356 mGy with an average value of 74.1 ± 45.5 mGy before 1949 while the younger population received up to about 100 mGy with an average value of 11.5 ± 37.7 mGy. (author)

  4. The Impact of Low Level X-rays on Biosynthesis of Gold Nanoparticles by Actinobacteria

    Directory of Open Access Journals (Sweden)

    Faranak Saghatchi

    2016-12-01

    Full Text Available Background: Gold nanoparticles (GNPs play an important role in medical, health and environmental applications. All kinds of microorganisms were found to be able to synthesize GNPs. The optimization of laboratory conditions for achieving more economical benefits of mass production has been studied widely. Methods: This study assesses the enhancing effect of low-level X-rays on the biosynthesis of GNPs by Actinomycetals. The isolated Actinomycetes were grown aerobically in MGYP broth media. The harvested bacteria were suspended in 50 mL aqueous HAuCl4 in 12 Erlenmeyer flask. Each group contained4 flasks. 2 groups of samples were irradiated by 30 mGy and 5 mGy X-rays respectively. The third group as control remained without irradiation. The solutions were shake- incubated for 120 h. Results: After 5 days, the color of first group samples changed from milky to purple, while the color changing occurred after 10 days in the 2nd group samples and the control samples. The UV-vis absorption spectrometry of the irradiated aqueous medium by 30 mGy X-rays confirmed the formation of GNPs. Conclusion: The findings showed that 30 mGy X-rays stimulated the microorganism to form GNPs in a half time in comparison to other groups.

  5. Diagnostic radiation and pregnancy

    International Nuclear Information System (INIS)

    Collins, L.; Fitzgerald, P.

    1983-01-01

    Accidental irradiation of the embryo or fetus in the first trimester is a problem which will occasionally occur. The value of a proper estimation of the radiation dose is emphasised. Very rarely does a single diagnostic procedure result in a uterine dose as high as 50 mGy. An accidental irradiation should rarely be cause for termination of a pregnancy

  6. Pilot survey of patient dose from computed tomography in Bulgaria

    International Nuclear Information System (INIS)

    Vassileva, Jenia; Stoyanov, Desislav

    2008-01-01

    The number of computed tomography (CT) scanners in Bulgaria increased from 22 in 1996 to more than 160 in 2007. Big variety of scanners of different manufacturers and different generations exists in the country with predominant number of single-slice scanners. Significant part of the scanners is more than 10 years old. This work presents the pilot results from the measurements of CT dose quantities started in 2005 with the aim to spread them to a national survey of CT practice in the country. It was found that different clinical protocols are used for similar examination, resulting in large variations in dose quantities: CT air kerma index varied from 27.1 to 78.4 mGy for head examination, from 8.7 to 28.3 mGy for chest, 11.8 - 30.7 mGy for abdomen and 9.1 - 41.3 mGy for pelvis. The CT air kerma-length product for complete examination was found to vary from 310 to 1254 mGy.cm for head examination, from 215 to 893 mGy.cm for chest, from 265 to 615 mGy.cm for abdomen and from 220 to 761 mGy.cm for pelvis. The analysis demonstrated that the main reasons for found variations are differences in scanning geometry, beam quality, exposure parameters and scanning length. (author)

  7. The influence of the Lop Nor Nuclear Weapons Test Base to the population of the Republic of Kazakhstan

    Energy Technology Data Exchange (ETDEWEB)

    Zhumadilov, Kassym, E-mail: kassym@hiroshima-u.ac.j [Research Institute for Radiation Biology and Medicine, Hiroshima University, 1-2-3, Kasumi, Minami-ku, Hiroshima 734-8553 (Japan); Ivannikov, Alexander [Medical Radiological Research Center, Korolev str. 4, Obninsk 249036 (Russian Federation); Zharlyganova, Dinara [Astana Medical University, Astana 010000 (Kazakhstan); Stepanenko, Valeriy [Medical Radiological Research Center, Korolev str. 4, Obninsk 249036 (Russian Federation); Zhumadilov, Zhaxybay [Nazarbayev University, Life Science Center, Astana 010000 (Kazakhstan); Apsalikov, Kazbek [Kazakh Scientific-Research Institute for Radiation Medicine and Ecology, Semey 071400 (Kazakhstan); Toyoda, Shin [Department of Applied Physics, Faculty of Science, Okayama University of Science, 1-1 Ridai, Okayama 700-0005 (Japan); Endo, Satoru [Department of Quantum Energy Applications, Graduate School of Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527 (Japan); Tanaka, Kenichi [Division of Physics, Department of Liberal Arts and Sciences, Center of Medical Education, Sapporo Medical University, South 1, West 17, Chuo-ku, Sapporo 060-8556 (Japan); Miyazawa, Chuzou [School of Dentistry, Ohu University, 31-1, Aza-Misumido, Tomita-machi, Koriyama-shi, Fukushima Pref. 963-8611 (Japan); Okamoto, Tetsuji [Department of Molecular Oral Medicine and Maxillofacial Surgery, Division of Frontier Medical Sciences, Graduate School of Biomedical Sciences, Hiroshima University (Japan); Hoshi, Masaharu [Research Institute for Radiation Biology and Medicine, Hiroshima University, 1-2-3, Kasumi, Minami-ku, Hiroshima 734-8553 (Japan)

    2011-04-15

    The method of electron spin resonance (ESR) dosimetry was applied to human tooth enamel to obtain estimates of individual absorbed dose for residents of Makanchi, Urdzhar and Taskesken settlements located near the Kazakhstan-Chinese border (about 400 km to the South-East, from the Semipalatinsk Nuclear Test Site (SNTS) and about 1000 km from the Lop Nor Nuclear Weapons Test Base, China). Since the ground and atmospheric nuclear tests (1964-1981) at Lop Nor, the people residing in these settlements are believed to have been heavily exposed to radioactive fallout. Tooth samples had been extracted for medical reasons during the course of ordinary dental treatment. The village of Kokpekty, located 400 km to the South-east of the SNTS, was chosen as the control group since it has not been subjected to any radioactive contamination. The mean excess doses in tooth enamel obtained after subtraction of the contribution of natural background radiation do not exceed 62 {+-} 28 mGy, 64 {+-} 30 mGy, 49 {+-} 27 mGy and -19 {+-} 36 mGy for all ages of the residents of Makanchi, Urdzhar, Taskesken and the control village of Kokpekty, respectively.

  8. Electron probe X-ray microanalysis of boar and inobuta testes after the Fukushima accident

    International Nuclear Information System (INIS)

    Yamashiro, Hideaki; Abe, Yasuyuki; Hayashi, Gohei; Urushihara, Yusuke; Kuwahara, Yoshikazu; Suzuki, Masatoshi; Kobayashi, Jin; Kino, Yasuyuki; Fukuda, Tomokazu; Tong, Bin; Takino, Sachio; Sugano, Yukou; Sugimura, Satoshi; Yamada, Takahisa; Isogai, Emiko; Fukumoto, Manabu

    2015-01-01

    We aimed to investigate the effect of chronic radiation exposure associated with the Fukushima Daiichi Nuclear Power Plant (FNPP) accident on the testes of boar and inobuta (a hybrid of Sus scrofa and Sus scrofa domestica). This study examined the contamination levels of radioactive caesium (Cs), especially 134 Cs and 137 Cs, in the testis of both boar and inobuta during 2012, after the Fukushima accident. Morphological analysis and electron-probe X-ray microanalysis (EPMA) were also undertaken on the testes. The 134 Cs and 137 Cs levels were 6430 ± 23 and 6820 ± 32 Bq/kg in the boar testes, and 755 ± 13 and 747 ± 17 Bq/kg in the inobuta testes, respectively. The internal and external exposure of total 134 Cs and 137 Cs in the boar testes were 47.1 mGy and 176.2 mGy, respectively, whereas in the inobuta testes, these levels were 6.09 mGy and 59.8 mGy, respectively. Defective spermatogenesis was not detected by the histochemical analysis of radiation-exposed testes for either animal. In neither animal were Cs molecules detected, using EPMA. In conclusion, we showed that adverse radiation-induced effects were not detected in the examined boar and inobuta testes following the chronic radiation exposure associated with the FNPP accident

  9. Chromosomal aberrations of blood lymphocytes induced in vitro by radon-222 daughter α-irradiation

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.; Lettner, H.; Hofmann, W.; Atzmueller, C; Eckl, P.; Haas, O.A.; Obe, G.; Grell-Buechtmann, I.; Van Buul, P.P.W.; Natarajan, A.T.; Schroeder-Kurth, T.; Sasaki, M.S.; Fischer, P.; Kubiak, R.

    2000-01-01

    Blood samples were irradiated in vitro with α-rays emitted from short-lived radon decay products dissolved in the culture medium at doses between 0.03 and 41.4 mGy. The data were collected from experiments conducted during the period 1984-1992 and comprise a total of about 64000 scored metaphases. For statistical reasons, only 60,022 metaphases were used for the subsequent analysis. The results for total chromosome aberrations and dicentrics indicate a linear dose dependence in the dose range above about 10 mGy, consistent with other experimental observations. At doses below about 10 mGy, aberration frequencies cannot be linearly extrapolated from higher doses, suggesting that there is no dependence on dose within a certain low-dose range. In addition, a statistically significant minimum has been observed at a dose of about 0.03 mGy, which is consistently lower than the related control values. The behavior of the aberration frequencies in the low-dose region seems to be influenced by the control values, which also depend on the environmental radiation burdens to the donors before blood sampling and thus were significantly affected by the Chernobyl fallout

  10. Theoretical Studies of Nanoclusters (Briefing Charts)

    Science.gov (United States)

    2015-07-23

    nanoclusters. However, scanning transmission electron microscopy ( STEM ) measures show cluster inversion occurred to produce MgyCux(!) a) copper atoms b...methane (née CLL -1) as a potential explosive ingredient: a theoretical study”, Propellants, Explosives, Pyrotechnics 38, 9-13 (2013). Jesus Paulo L

  11. Towards establishing DRLs for digital mammography in Australia

    International Nuclear Information System (INIS)

    Diffey, J.L; Carteright, L.E.; Collins, L.T.; Grewal, R.K.

    2011-01-01

    Full text: Breastscreen NSW is one of the first breast screening programs to be fully digital. Exposure data is stored in the DICOM image header, making it readily accessible for assessing patient dose. The aim of this work was to determine diagnostic reference levels (DRLs) for the screening program. Approximately 100 examinations, consisting of two views of each breast, were obtained for each system from the central PACS. Third party software was then used to extract the relevant exposure parameters. The mean glandular dose (MGD) was calculated for each image using the methods described by Wu, Boone and Dance. The DRL was calculated from the average mean glandular dose for mediolateral oblique (MLO) views with compressed breast thicknesses of 50-60 mm. For the whole sample, the average MLO compressed breast thickness was 58.84 mm with an average compression force of 109.25 N. The average MGD (Dance) for each examination was 2.93 mGy, compared with 4.6 mGy for film-screen systems. The DRL for CR systems (Dance) was 1.85 mGy, and for DR systems it was 1.13 mGy.

  12. Immobilization of cellulose producing cells (sporotrichum cellulophilum) using irradiated rice husk as a substrate

    International Nuclear Information System (INIS)

    Lina, M.R.; Tamada, M.; Kumakura, M.

    1991-01-01

    An experiment to study the effect of irradiated rice husk as a substrate on cellulase production of free and immobilized cells of S. cellulophium was carried out. Radiation pretreatment of rice husk was done using electron beam accelerator (Dynamitron IEA 3000-25,2), with doses of 0, 0.2, 0.4, 0.6, 0.8, and 1.0 MGy. The substrate used in cellulase production of free and immobilized cells were cellulose powder as a standard, and 1.0 MGy irradiated rice husk. Concentrations of cellulose powder for free and immobilized cells were 1, 2, 3, 5, and 8% (w/v). Irradiated rice husk concentrations for free cells were 3, 6, 9, 15, and 24% (w/v), whereas for immobilized cells were 3, 6, and 9% (w/v). Results showed that glucose concentration in 1.0 MGy irradiated rice husk was the highest of all irradiated and unirradiated rice husks. The GPA (glucose production activity) values used of free immobilized cells of S. cellulophium in medium containing 1.0 MGy irradiated rice husk were about 50% lower than in cellulose powder medium. Cellulase solution resulted by immobilized cells, either in cellulose powder or in irradiated rice husk media, were clear and did not contain mycelium. (authors). 7 refs, 7 figs

  13. Occupational exposure to staff during endoscopic retrograde cholangiopancreatography in Sudan

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Khalil, M.

    2011-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) procedure is an invasive technique that requires fluoroscopic and radiographic exposure. The purpose of this study was to determine the occupational dose of ionising radiation at three gastroenterology departments (Fedial, Soba and Ibn seena hospitals) in Khartoum (Sudan). The radiation dose was measured during 55 therapeutic ERCP procedures. Thermoluminescence dosemeters were used. The mean radiation dose for the first operator was 0.27 mGy for the eye lens, 0.21 for the thyroid, 0.32 for the chest, 0.17 for the hand and 0.22 for the leg. The mean radiation dose for the second operator was 0.21 mGy for the hand and 0.20 mGy for the chest, while the mean radiation dose for the nurse was 0.44 mGy for the hand and 0.19 for the chest. The radiation dose received by the staff in these hospitals was found to be higher than most of the values in the literature. The radiation absorbed dose received by the different organs is relatively low. Additional studies need to be conducted for radiation dose optimisation. (authors)

  14. Level of patient and operator dose in the largest cardiac centre in Greece

    International Nuclear Information System (INIS)

    Tsapaki, V.; Patsilinakos, S.; Voudris, V.; Magginas, A.; Pavlidis, S.; Maounis, T.; Theodorakis, G.; Koutelou, M.; Vrantza, T.; Nearchou, M.; Nikolaki, N.; Kollaros, N.; Kyrozi, E.; Kottou, S.; Karaiskos, P.; Neofotistou, E.; Cokkinos, D.

    2008-01-01

    The objective of this study was to investigate the patient and staff doses in the most frequent interventional cardiology (IC) procedures performed in Onassio, the largest Cardiac Centre in Greece. Data were collected from three digital X-ray systems for 212 coronary angiographies, 203 percutaneous transluminal coronary angio-plasties (PTCA) and 134 various electrophysiological studies. Patient skin dose was measured using suitably calibrated slow radiotherapy films and cardiologist dose using suitably calibrated thermoluminescent dosemeters placed on left arm, hand and foot. Patient median dose area product (DAP) (all examinations) ranged between 6.7 and 83.5 Gy cm 2 . Patient median skin dose in PTCA was 799 mGy (320-1660 mGy) and in RF ablation 160 mGy (35-1920 mGy). Median arm, hand and foot dose to the cardiologist were 12.6, 27 and 13 μSv, respectively, per procedure. The great range of radiation doses received by both patients and operators confirms the need for continuous monitoring of all IC techniques. (authors)

  15. Estimates of Average Glandular Dose with Auto-modes of X-ray Exposures in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Izdihar Kamal

    2015-05-01

    Full Text Available Objectives: The aim of this research was to examine the average glandular dose (AGD of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. Methods: This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50 and 20% glandular and 80% adipose tissue (20/80 commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA with auto-time, auto-filter and auto-kilovolt modes. Results: The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy for two dimension (2D and 2.48 mGy for three dimensional (3D images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. Conclusion: The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.

  16. Radiation doses to children with shunt-treated hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Holmedal, Lise J. [Helse Fonna, Department of Radiology, Stord Hospital, Stord (Norway); Friberg, Eva G.; Boerretzen, Ingelin; Olerud, Hilde [The Norwegian Radiation Protection Authority, Oesteraas (Norway); Laegreid, Liv [Haukeland University Hospital, Department of Paediatrics, Bergen (Norway); Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Radiology Section, Bergen (Norway); Great Ormond Street Hospital for Children, Department of Diagnostic Radiology, London (United Kingdom)

    2007-12-15

    Children with shunt-treated hydrocephalus are still followed routinely with frequent head CT scans. To estimate the effective dose, brain and lens doses from these examinations during childhood, and to assess dose variation per examination. All children born between 1983 and 1995 and treated for hydrocephalus between 1983 and 2002 were included. We retrospectively registered the number of examinations and the applied scan parameters. The effective dose was calculated using mean conversion factors from the CT dose index measured free in air, while doses to the lens and brain were estimated using tabulated CT dose index values measured in a head phantom. A total of 687 CT examinations were performed in 67 children. The mean effective dose, lens dose and brain dose to children over 6 months of age were 1.2 mSv, 52 mGy and 33 mGy, respectively, and the corresponding doses to younger children were 3.2 mSv, 60 mGy and 48 mGy. The effective dose per CT examination varied by a factor of 64. None of the children was exposed to doses known to cause deterministic effects. However, since the threshold for radiation-induced damage is not known with certainty, alternative modalities such as US and MRI should be used whenever possible. (orig.)

  17. Skeletal muscle deiodinase type 2 regulation during illness in mice

    NARCIS (Netherlands)

    Kwakkel, J.; van Beeren, H. C.; Ackermans, M. T.; Platvoet-ter Schiphorst, M. C.; Fliers, E.; Wiersinga, W. M.; Boelen, A.

    2009-01-01

    We have previously shown that skeletal muscle deiodinase type 2 (D2) mRNA (listed as Dio2 in MGI Database) is up-regulated in an animal model of acute illness. However, human Studies on the expression Of muscle D2 during illness report conflicting data. Therefore, we evaluated the expression of

  18. Dosimetry of cone beam computed tomography scanning for diagnosis and planning in implant dentistry

    International Nuclear Information System (INIS)

    Santos Pinto de A, E. L.; Manzi, F. R.; Goncalves Z, E.; Nogueira, M. S.; Fernandes Z, M. A.

    2015-10-01

    Full text: The radiation dose and estimate the radiation induced risk of cancer and morpho functional alterations according to BEIR VII (2006) and recommendations of the ICRP 103 (2007) were measured in cone beam computed tomography (CBCT) scanning (Tc Kodak 9000C 3D) in different oral and maxillofacial regions for diagnosis and planning in implant dentistry for each examination protocol: jaw full, maxilla full and jaw and maxilla full associated. Thermoluminescent dosimeters (TLD- 100 H) were placed in an Alderson-Rando in regions corresponding to the crystalline, parotid, submandibular and thyroid glands and ovaries. The highest values for entrance skin dose were observed in the region of the parotid and submandibular glands, 9.612 mGy to 7.912 mGy and 8.818 mGy to 0.483 mGy, respectively. All examination protocols presented on the right and left sides in the region of the submandibular gland the highest values for absorbed dose (D). In the jaw full exam the thyroid glands on both sides presented highest dose values than maxilla full exam. This study allowed measuring the entrance skin dose and the absorbed dose (D) highlighting a dosimetric preponderance to the salivary glands. With danger of to radiation that induces cancer risk was observed that the age group most likely to have to risk of cancer was 20 years, compared to 30, 40, 50, 60,70 and 80 years. (Author)

  19. Low-dose/dose-rate γ radiation depresses neural differentiation and alters protein expression profiles in neuroblastoma SH-SY5Y cells and C17.2 neural stem cells.

    Science.gov (United States)

    Bajinskis, Ainars; Lindegren, Heléne; Johansson, Lotta; Harms-Ringdahl, Mats; Forsby, Anna

    2011-02-01

    The effects of low doses of ionizing radiation on cellular development in the nervous system are presently unclear. The focus of the present study was to examine low-dose γ-radiation-induced effects on the differentiation of neuronal cells and on the development of neural stem cells to glial cells. Human neuroblastoma SH-SY5Y cells were exposed to (137)Cs γ rays at different stages of retinoic acid-induced neuronal differentiation, and neurite formation was determined 6 days after exposure. When SH-SY5Y cells were exposed to low-dose-rate γ rays at the onset of differentiation, the number of neurites formed per cell was significantly less after exposure to either 10, 30 or 100 mGy compared to control cells. Exposure to 10 and 30 mGy attenuated differentiation of immature C17.2 mouse-derived neural stem cells to glial cells, as verified by the diminished expression of glial fibrillary acidic protein. Proteomic analysis of the neuroblastoma cells by 2D-PAGE after 30 mGy irradiation showed that proteins involved in neuronal development were downregulated. Proteins involved in cell cycle and proliferation were altered in both cell lines after exposure to 30 mGy; however, the rate of cell proliferation was not affected in the low-dose range. The radiation-induced attenuation of differentiation and the persistent changes in protein expression is indicative of an epigenetic rather than a cytotoxic mechanism.

  20. Latif et al (18)

    African Journals Online (AJOL)

    DELL

    irradiation source to a test dose of 1.2 mGy and the heating rates of β = 1, 3 and 5 Cs were considered, in order to minimize the effect of ... properties of inorganic materials allows not only ... dose over a wide range and (iii) the ability to store.

  1. Combustion synthesis and preliminary luminescence studies of ...

    Indian Academy of Sciences (India)

    were used such as lithium nitrate (LiNO3), barium nitrate. (BaNO3)2, ammonium .... packed in aluminium foil under 100mGy beta-ray radia- tions. Figure 3 .... 20. Shaat S K K, Swart H C and Ntwaeaborwa O M 2014 J. Alloys. Compd. 587 600.

  2. Ionizing radiations dosimetry: new results in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.

    1989-01-01

    Industrial irradiation for food preservation, medical sterilization and plastic processing is in great expansion and an accurate dosimetry in the megagray range is required. It is also required for safety purposes around nuclear reactors or waste storage sites. The study of photon-matter interaction leads us to consider high-dose dosimeters among the solids in which radiolysis occurs. Organic conductors are indeed good candidates for high-dose dosimetry. These materials show original properties due to the great anisotropy of their electronic system. Radiation effects, especially on the resistivity and on the (E.S.R.) Electron Spin Resonance linewidth, are very important. We show that a simple resistance measurement allows an accurate monitoring of the absorbed dose, in the range 0.01 - 50 MGy, for X-rays, gamma-rays and electron irradiations. The E.S.R. linewidth measurements permits the use of small dosimeters between 1 and 100 MGy. Finally, some organic conductors are proposed as high-temperature dosimeters for irradiation performed up to 120 0 C. The irradiated pure silica contains a large variety of defects. Only the E' center seems helpful for dosimetry purposes, and its electron spin resonance (E.S.R.) signal is simply related to the absorbed dose in the range 0.1 - 3 MGy or even, 0.5 kGy - 5 MGy [fr

  3. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Di Leo, Giovanni; Zanardo, Moreno; Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Spadavecchia, Chiara [Universita degli Studi di Milano, Dipartimento di Fisica, Milano (Italy); Veronese, Ivan [Universita degli Studi di Milano, Dipartimento di Fisica, Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Cantone, Marie Claire [Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Milano (Italy); Sardanelli, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Universita degli Studi di Milano, Department of Biomedical Science for Health, San Donato Milanese (Italy)

    2017-07-15

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. (orig.)

  4. High pressure gas - a new approach to calorimetry

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The high particle collision rate and radiation levels in detectors at the new high energy high luminosity proton colliders (SSC, LHC, UNK) put stringent demands on the design of detector components. In particular the forward calorimeters will have to deal with particle fluxes in excess of 4 x 106 per sq cm per s and high radiation doses (at the MGy level)

  5. Radiation dose with digital breast tomosynthesis compared to digital mammography. Per-view analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gennaro, Gisella [Veneto Institute of Oncology IOV- IRCCS, Radiology Unit, Padua (Italy); Bernardi, D. [Azienda Provinciale Servizi Sanitari (APSS), U.O. Senologia Clinica e Screening Mammografico, Department of Diagnostics, Trento (Italy); Houssami, N. [University of Sydney, Screening and Test Evaluation Program (STEP), School of Public Health, Sydney Medical School, Sydney (Australia)

    2018-02-15

    To compare radiation dose delivered by digital mammography (FFDM) and breast tomosynthesis (DBT) for a single view. 4,780 FFDM and 4,798 DBT images from 1,208 women enrolled in a screening trial were used to ground dose comparison. Raw images were processed by an automatic software to determine volumetric breast density (VBD) and were used together with exposure data to compute the mean glandular dose (MGD) according to Dance's model. DBT and FFDM were compared in terms of operation of the automatic exposure control (AEC) and MGD level. Statistically significant differences were found between FFDM and DBT MGDs for all views (CC: MGD{sub FFDM}=1.366 mGy, MGD{sub DBT}=1.858 mGy; p<0.0001; MLO: MGD{sub FFDM}=1.374 mGy, MGD{sub DBT}=1.877 mGy; p<0.0001). Considering the 4,768 paired views, Bland-Altman analysis showed that the average increase of DBT dose compared to FFDM is 38 %, and a range between 0 % and 75 %. Our findings show a modest increase of radiation dose to the breast by tomosynthesis compared to FFDM. Given the emerging role of DBT, its use in conjunction with synthetic 2D images should not be deterred by concerns regarding radiation burden, and should draw on evidence of potential clinical benefit. (orig.)

  6. Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Alkhorayef, M.; Babikir, E.; Abuzaid, M.; Dalton, A.; Bradley, D.

    2015-10-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive technique that has been used for over 30 years in the diagnosis and management of pancreaticobiliary disorders. The objectives of this study were to evaluate the patient entrance surface air kerma doses (ESAK) and estimate the organ and effective doses during ERCP in three hospitals in Khartoum. A total of 55 patients were examined in three hospitals in Khartoum state, Sudan. Calibrated thermoluminescence dosimeters (TLD)-Gr-200-A)) were used to measure patients ESAK. The overall mean of ESAK for all ERCP procedures was 42.4 mGy. The mean patient ESAK in Fedail, Soba and Ibn sena centers were 26.7 mGy, 26.0 mGy, 72.4 mGy, respectively. The effective doses in three centers were 1.6, 1.56 and 2.67 mSv in that order and the overall mean effective dose was 2.01 mSv. Patient radiation doses vary widely among the different hospitals. Patient ESAK is low compared to previous studies in the light of the current practice. Patient dose was decreased significantly in the last two decades. (Author)

  7. Occupational radiation exposure in the GDR in 1978

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1978, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,980 persons), measurements with a whole-body counter (186 persons) and analyses of biosamples (144 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 427. In 13 cases the monthly exposure exceeded 30 mGy, 8 persons received annual doses in the range of 50 to 120 mGy, and the highest annual dose was above 250 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual internal radiation exposure was well below one-tenth the maximum permissible dose. (author)

  8. Radiation hormesis using an x-ray radiography device. The fourth report. Radiation hormesis of salad rocket

    International Nuclear Information System (INIS)

    Sakuma, Atsushi; Nakayama, Miho

    2006-01-01

    Radiation hormesis was studied for salad rocket plant (Eruca vesicaria sp.sativa), using different energies of X-ray (100 kV and 10 MV). To get the optimum dose for plant to provide the highest growth, the dose for the seeds was changed from 0 to 3000 mGy using 100 kV of X-ray. The highest growth of the plant was found for the dose of 600 mGy. When the seeds were irradiated to 600 mGy with 100 kV and 10 MV X-rays, in both cases, the growth of the irradiated seeds was higher than those without irradiation, where P-values were 0.0112 and 0.0214, respectively. In the case of 600 mGy irradiation, there was not any significant change in the plant growth between the seeds irradiated with 10 MV and 100 kV X-ray (P=0.862). (author)

  9. Radiation exposure of the gonads in infant brain computerized tomography

    International Nuclear Information System (INIS)

    Berndt, L.; Rosenkranz, G.; Tellkamp, H.

    1988-01-01

    In 61 babies and infants the gonadal dose due to brain computerized tomography was determined over the symphysis by thermoluminescent dosimetry. The average radiation dose was 43 mGy corresponding with data reported. Shielding of the testes in infants is an additional burden and worth discussing because of the low absolute gonadal dose

  10. Chernobyl's Subclinical Legacy: Prenatal Exposure to Radioactive Fallout and School Outcomes in Sweden. NBER Working Paper No. 13347

    Science.gov (United States)

    Almond, Douglas; Edlund, Lena; Palme, Marten

    2007-01-01

    Japanese atomic bomb survivors irradiated 8-25 weeks after ovulation subsequently suffered reduced IQ [Otake and Schull, 1998]. Whether these findings generalize to low doses (less than 10 mGy) has not been established. This paper exploits the natural experiment generated by the Chernobyl nuclear accident in April 1986, which caused a spike in…

  11. Cesium-137 uptake studies on ammonium phospho molybdate irradiated with electrons

    International Nuclear Information System (INIS)

    Rao, K.L.N.; Balasubramanian, K.R.; Shukla, J.P.

    1992-01-01

    Ammonium phospho molybdate is an important inorganic ion exchanger having high selectivity for cesium. This paper discusses the effects of electron irradiation to a dose of 1 mGy on this exchanger with special reference to its ion exchange performance using cesium-137 as a tracer. An explanation is attempted for the slight increase in the distribution coefficients. (author). 5 refs., 1 tab

  12. Analysis of Dose and Dose Distribution for Patients Undergoing Selected X-Ray Diagnostic Procedures in Ghana

    Energy Technology Data Exchange (ETDEWEB)

    Schandorf, C.; Tetteh, G.K

    1998-07-01

    The levels of dose and dose distributions for adult patients undergoing five selected common types of X ray examination in Ghana were determined using thermoluminescence dosemeters (TLD) attached to the skin where the beam enters the patient. To assess the performance of each X ray room surveyed, the mean of the entrance surface dose for patients whose statistics were close to a standard patient (70 kg weight and 20 cm AP trunk thickness) were compared to the Commission of the European Communities guideline values for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP examinations. The third quartiles dose values were 1.3 mGy, 14.5 mGy, 12.0 mGy and 7.9 mGy for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP respectively. Analysis of the data show that 86%, 58%, 37.5% and 50% of radiographic rooms delivered a mean dose greater than the CEC guideline values for chest PA, lumbar spine AP, pelvis/abdomen and skull AP respectively. This suggests that radiographic departments should undertake a review of their radiographic practice in order to bring their doses to optimum levels. (author)

  13. Analysis of Dose and Dose Distribution for Patients Undergoing Selected X-Ray Diagnostic Procedures in Ghana

    International Nuclear Information System (INIS)

    Schandorf, C.; Tetteh, G.K.

    1998-01-01

    The levels of dose and dose distributions for adult patients undergoing five selected common types of X ray examination in Ghana were determined using thermoluminescence dosemeters (TLD) attached to the skin where the beam enters the patient. To assess the performance of each X ray room surveyed, the mean of the entrance surface dose for patients whose statistics were close to a standard patient (70 kg weight and 20 cm AP trunk thickness) were compared to the Commission of the European Communities guideline values for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP examinations. The third quartiles dose values were 1.3 mGy, 14.5 mGy, 12.0 mGy and 7.9 mGy for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP respectively. Analysis of the data show that 86%, 58%, 37.5% and 50% of radiographic rooms delivered a mean dose greater than the CEC guideline values for chest PA, lumbar spine AP, pelvis/abdomen and skull AP respectively. This suggests that radiographic departments should undertake a review of their radiographic practice in order to bring their doses to optimum levels. (author)

  14. Establishment of diagnostic reference levels for dental panoramic radiography in Greece

    International Nuclear Information System (INIS)

    Manousaridis, G.; Koukorava, C.; Hourdakis, C.J.; Kamenopoulou, V.; Yakoumakis, E.; Tsiklakis, K.

    2015-01-01

    The purpose of the present study was to present the national diagnostic reference levels (DRL) established for panoramic dental examinations in Greece. The establishment of DRL, as a tool for the optimisation of radiological procedures, is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 90 panoramic systems have been used for the derivation of DRL values. DRL values have been proposed for exposure settings of different patient types (child, small adult and standard adult), both for film and digital imaging. The DRLs for different patient types are grouped in three categories: children, small adults (corresponding to female) and average adults (corresponding to male). Proposed DRLs for these groups are 2.2, 3.3 and 4.1 mGy, respectively. In order to investigate the correlation of DRLs with the available imaging modalities (CR, DR and film), this parameter was taken into account. DR imaging DRL is the lowest at 3.5 mGy, CR imaging the highest at 4.2 mGy and film imaging at 3.7 mGy. In order to facilitate comparison with other studies, kerma-width product values were calculated from K i , air and field size. (authors)

  15. The rate of X-ray-induced DNA double-strand break repair in the embryonic mouse brain is unaffected by exposure to 50 Hz magnetic fields.

    Science.gov (United States)

    Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2015-06-01

    Following in utero exposure to low dose radiation (10-200 mGy), we recently observed a linear induction of DNA double-strand breaks (DSB) and activation of apoptosis in the embryonic neuronal stem/progenitor cell compartment. No significant induction of DSB or apoptosis was observed following exposure to magnetic fields (MF). In the present study, we exploited this in vivo system to examine whether exposure to MF before and after exposure to 100 mGy X-rays impacts upon DSB repair rates. 53BP1 foci were quantified following combined exposure to radiation and MF in the embryonic neuronal stem/progenitor cell compartment. Embryos were exposed in utero to 50 Hz MF at 300 μT for 3 h before and up to 9 h after exposure to 100 mGy X-rays. Controls included embryos exposed to MF or X-rays alone plus sham exposures. Exposure to MF before and after 100 mGy X-rays did not impact upon the rate of DSB repair in the embryonic neuronal stem cell compartment compared to repair rates following radiation exposure alone. We conclude that in this sensitive system MF do not exert any significant level of DNA damage and do not impede the repair of X-ray induced damage.

  16. Level and distribution of the radiation dose to the population from a mammography screening programme in New Zealand

    Energy Technology Data Exchange (ETDEWEB)

    Bulling, S.M.; Nicoll, J.J. [Otago Univ., Dunedin (New Zealand). Dept. of Physics

    1995-12-31

    The Otago Southland Breast Screening Programme offers biennial mammography to 19,000 eligible women on the South Island of New Zealand. A Quality Assurance programme ensures that international performance standards are met, in particular the radiation dose for a mammogram of 5 cm CIRS-X phantom is 1.7 mGy and careful retake analysis undertaken. This however does not reveal the absorbed dose received by individuals, nor how this varies between individuals. Machine parameters and compressed breast thickness for each film were recorded for 310 women who attended one centre during the three months ending February 1993 and absorbed doses calculated using Monte Carlo data. The mean compressed breast thickness for the 310 women was 4.9 cm, doses received for individual films ranged from 0.7 to 8.5 mGy while patient total doses were in the range 4 to 29 mGy with 75% of women receiving a dose of 7.1 mGy or less. (Author).

  17. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study

    International Nuclear Information System (INIS)

    Di Leo, Giovanni; Zanardo, Moreno; Secchi, Francesco; Spadavecchia, Chiara; Veronese, Ivan; Cantone, Marie Claire; Sardanelli, Francesco

    2017-01-01

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. (orig.)

  18. Radiation doses from mammography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Young, B.F.; Young, J.G.; Tingey, D.R.C.

    1991-05-01

    During 1989-90 the Australian Radiation Laboratory conducted a postal survey of at least 90% of the mammographic facilities in Australia. The primary aim of the survey was to measure the mean glandular dose (MGD) and the X-ray beam half value layer (HVL) for a typical mammograph. The MGD and HVL were measured with a specially designed tissue equivalent monitor. In all, 258 mammographic centres were surveyed. It was found that for centres using film-screen imaging, the average mean glandular dose was 1.83 mGy for centres using grids and 0.84 mGy for centres not using grids. In addition to the MGD and HVL, comprehensive statistical information was collected and data is presented on the types of equipment and techniques used, the number and age of patients and demographic distribution of centres. Results indicate that the use of a grid is the major factor determining dose and several other factors appear to have minor effects. In view of the distribution of MGD, it is recommended that the mean glandular dose per image, for a 5 cm compressed breast thickness, should not exceed 2.0 mGy when a grid is used and 1.0 mGy without a grid. 63 refs., 11 tabs., 15 figs

  19. Mutational influences of low-dose and high let ionizing radiation in drosophila melanogaster

    Science.gov (United States)

    Lei, Huang; Fanjun, Kong; Sun, Yeqing

    For cosmic environment consists of a varying kinds of radiation particles including high Z and energy ions which was charactered with low-dose and high RBE, it is important to determine the possible biofuctions of high LET radiation on human beings. To analyse the possible effectes of mutational influences of low-dose and high-LET ionizing radiation, wild fruit flies drosophila melanogaster were irradiated by 12C6+ ions in two LET levels (63.3 and 30 keV/µum) with different low doses from 2mGy to 2000mGy (2, 20, 200, 2000mGy) in HIRFL (Heavy ion radiation facility laboratory, lanzhou, China).In the same LET value group, the average polymorphic frequency was elevated along with adding doses of irradation, the frequency in 2000 mGy dose samples was significantly higher than other samples (p<0.01).These results suggest that genomic DNA sequence could be effected by low-dose and high-LET ionizing radiation, the irradiation dose is an important element in genomic mutation frequency origination.

  20. Study of an optimization protocol for radiographic techniques in computerized radiology

    International Nuclear Information System (INIS)

    Abrantes, Marcos Eugenio Silva

    2015-01-01

    This work is designed to produce information for the improvement of image quality to deployment in a radiology department based on previous reviews of the images by questionnaires of acceptance and quality e recognition of the parameters used in chest radiographic techniques. The data collected were divided by male, female, PA and LAT thickness, body mass index, biotypes, anthropomorphic parameters and body evaluation associated with constant voltage and the additional filtration. The results show the predominance of 35 and 40 constants with additional filtration from 0.5 to 1.5 mmAl, voltage in male: (PA and LAT) 86-92 kV and 96-112 kV, female: 85-98 kV and 96-112 kV. The charge applied to the tube for males: (PA and LAT) 5-10 mA.s and 5-16 mA.s, female: (PA and LAT) 6.3-8 mA.s and 9-14 mA.s. Absorbed doses for males: (PA and PF) 0.04-0.17 mGy and 0.03-0.19 mGy and from female (PA and PF) from 0.03-0.22 mGy and 0, 04-0.17 mGy. This procedure can be used in radiology department to implement and acceptance in the quality of images. (author)

  1. Crystal growth and thermoluminescence response of NaZr2(PO4)3 at high gamma radiation doses

    International Nuclear Information System (INIS)

    Ordóñez-Regil, E.; Contreras-Ramírez, A.; Fernández-Valverde, S.M.; González-Martínez, P.R.; Carrasco-Ábrego, H.

    2013-01-01

    Graphical abstract: -- Highlights: •NaZr 2 (PO 4 ) 3 exposed to gamma doses of 10, 30 and 50 MGy. •Gamma radiation produced growth of the crystal size of the NZP. •Morphology changes were reversible by heating. •Linear relationship between the thermoluminescence and the applied gamma dose. •This property could be useful for high-level gamma dosimetry. -- Abstract: This work describes the synthesis and characterization of NaZr 2 (PO 4 ) 3 . The stability of this material under high doses of gamma radiation was investigated in the range of 10–50 MGy. Samples of unaltered and gamma irradiated NaZr 2 (PO 4 ) 3 were characterized by X-ray diffraction, infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, and thermoluminescence. The results showed that while functional groups were not affected by the gamma irradiation, morphology changes were observed with increasing doses of gamma irradiation. The morphology of the non-irradiated compound is agglomerated flakes; however, irradiation at 10 MGy splits the flakes inducing the formation of well-defined cubes. Gamma irradiation induced the crystal size of the NaZr 2 (PO 4 ) 3 to grow. The heat treatment (973 K) of samples irradiated at 50 MGy resulted in the recovery of the original morphology. Furthermore, the thermoluminescence analysis of the irradiated compound is reported

  2. Dosimetry of cone beam computed tomography scanning for diagnosis and planning in implant dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Santos Pinto de A, E. L.; Manzi, F. R.; Goncalves Z, E. [Pontifical Catholic University of Minas Gerais, Av. Jose Gaspar 500, 30535-901 Belo Horizonte, Minas Gerais (Brazil); Nogueira, M. S.; Fernandes Z, M. A., E-mail: madelon@cdtn.br [Development Center of Nuclear Technology / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Full text: The radiation dose and estimate the radiation induced risk of cancer and morpho functional alterations according to BEIR VII (2006) and recommendations of the ICRP 103 (2007) were measured in cone beam computed tomography (CBCT) scanning (Tc Kodak 9000C 3D) in different oral and maxillofacial regions for diagnosis and planning in implant dentistry for each examination protocol: jaw full, maxilla full and jaw and maxilla full associated. Thermoluminescent dosimeters (TLD- 100 H) were placed in an Alderson-Rando in regions corresponding to the crystalline, parotid, submandibular and thyroid glands and ovaries. The highest values for entrance skin dose were observed in the region of the parotid and submandibular glands, 9.612 mGy to 7.912 mGy and 8.818 mGy to 0.483 mGy, respectively. All examination protocols presented on the right and left sides in the region of the submandibular gland the highest values for absorbed dose (D). In the jaw full exam the thyroid glands on both sides presented highest dose values than maxilla full exam. This study allowed measuring the entrance skin dose and the absorbed dose (D) highlighting a dosimetric preponderance to the salivary glands. With danger of to radiation that induces cancer risk was observed that the age group most likely to have to risk of cancer was 20 years, compared to 30, 40, 50, 60,70 and 80 years. (Author)

  3. Dosimetry using Gafchromic XR-RV2 radiochromic films in interventional radiology

    International Nuclear Information System (INIS)

    Neocleous, A.; Yakoumakis, E.; Gialousis, G.; Dimitriadis, A.; Yakoumakis, N.; Georgiou, E.

    2011-01-01

    Patient dose measurements of local entrance dose to the skin have been carried out using radiochromic film (Gafchromic XR-RV2) in a sample of interventional procedures. The major aim of the work was to measure patient entrance dose from such examinations using Gafchromic XR-RV2. Forty-five various interventional procedures (including nephrostomies and urinary stenting, biliary stenting and percutaneous transhepatic biliary drainage (PTBD) and aorta stent grafting) were evaluated. Maximum entrance doses were 537±119 mGy in nephrostomies, 943±631 mGy in biliary stenting and PTBD and 2425±569 mGy in aorta stent grafting. Results indicate that all patients undergoing aorta stent grafting received skin dose above 1500 mGy, which means that there is an increasing potential to suffer radiation-induced skin injuries. The film provides dose mapping, the position of the skin area with highest dose and can be used for immediate qualitative and as well as for quantitative assessment of patient skin dose. (authors)

  4. SU-E-I-15: Comparison of Radiation Dose for Radiography and EOS in Adolescent Scoliosis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B; Walz-Flannigan, A [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: To estimate patient radiation dose for whole spine imaging using EOS, a new biplanar slot-scanning radiographic system and compare with standard scoliosis radiography. Methods: The EOS imaging system (EOS Imaging, Paris, France) consists of two orthogonal x-ray fan beams which simultaneously acquire frontal and lateral projection images of a standing patient. The patient entrance skin air kerma was measured for each projection image using manufacturer-recommended exposure parameters for spine imaging. Organ and effective doses were estimated using a commercially-available Monte Carlo simulation program (PCXMC, STUK, Radiation and Nuclear Safety Authority, Helsinki, Finland) for a 15 year old mathematical phantom model. These results were compared to organ and effective dose estimated for scoliosis radiography using computed radiography (CR) with standard exposure parameters obtained from a survey of pediatric radiographic projections. Results: The entrance skin air kerma for EOS was found to be 0.18 mGy and 0.33 mGy for posterior-anterior (PA) and lateral projections, respectively. This compares to 0.76 mGy and 1.4 mGy for CR, PA and lateral projections. Effective dose for EOS (PA and lateral projections combined) is 0.19 mSv compared to 0.51 mSv for CR. Conclusion: The EOS slot-scanning radiographic system allows for reduced patient radiation dose in scoliosis patients as compared to standard CR radiography.

  5. Reducing the radiation dose to the eye lens region during CT brain examination: the potential beneficial effect of the combined use of bolus and a bismuth shield

    International Nuclear Information System (INIS)

    Lai, C.W.K.; Chan, T.P.; Cheung, H.Y.; Wong, T.H.

    2015-01-01

    Objective: Computed Tomography (CT) is the leading contributor to medical exposure to ionizing radiation. Although the use of CT brain scans for patients with head injuries and convulsions has shown a tremendous growth, it has raised substantial concerns in the general public because of the risk of radiation-induced cataracts: the current available strategies to reduce the radiation dose to the eye lens region are limited. Therefore, the present research project was initiated with the aim of evaluating the potential benefit of the combined use of bolus and a bismuth shield on reducing the radiation dose to the eye lens region during CT brain examination. Materials and methods: We conducted a series of phantom studies to measure the entrance surface dose (ESD) that is delivered to the eye lens region during CT brain examination under the effect of different scanning and shielding setups. Results: Our results indicated, during CT brain examination: (1) a drastic reduction of 92.5% in the ESD to the eye lens region was found when the CT gantry was tilted from 0 deg. (overall ESD = 30.7 mGy) to 30 deg. cranially (overall ESD = 2.4 mGy), and (2) when the CT gantry was positioned at 0 deg. (the common practice in the clinical setting), the setups with the application of a) a bismuth shield, b) a bismuth shield with a face shield (air gap), c) a bismuth shield with bolus, and d) a bismuth shield with bolus and an air gap can result in an acceptable level of image quality with a smaller overall ESD delivered to the eye lens region (overall ESD = 23.2 mGy, 24 mGy, 21 mGy and 19.9 mGy, respectively) than the setup without the bismuth shield applied (overall ESD = 30.7 mGy). Conclusion: When the primary beam scanning through the eye lens region is unavoidable during CT brain examination, the combined use of a bismuth shield with bolus and a face shield is an easy-to-use and inexpensive shielding setup to reduce the radiation dose delivered to the eye lens region while

  6. The long-term effects of acute exposure to ionising radiation on survival and fertility in Daphnia magna

    Energy Technology Data Exchange (ETDEWEB)

    Sarapultseva, Elena I. [Department of Biology, Institute of Nuclear Power Engineering NRNU MEPhI, Studgorodok,1, Obninsk, Kaluga Region 249040 (Russian Federation); National Research Nuclear University “MEPhI”, Kashirskoe Highway, 31, Moscow 115409 (Russian Federation); Dubrova, Yuri E., E-mail: yed2@le.ac.uk [Department of Genetics, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Vavilov Institute of General Genetics, Russian Academy of Sciences, Gubkina Str. 3, 11933 Moscow (Russian Federation)

    2016-10-15

    The results of recent studies have provided strong evidence for the transgenerational effects of parental exposure to ionising radiation and chemical mutagens. However, the transgenerational effects of parental exposure on survival and fertility remain poorly understood. To establish whether parental irradiation can affect the survival and fertility of directly exposed organisms and their offspring, crustacean Daphnia magna were given 10, 100, 1000 and 10,000 mGy of acute γ-rays. Exposure to 1000 and 10,000 mGy significantly compromised the viability of irradiated Daphnia and their first-generation progeny, but did not affect the second-generation progeny. The fertility of F{sub 0} and F{sub 1}Daphnia gradually declined with the dose of parental exposure and significantly decreased at dose of 100 mGy and at higher doses. The effects of parental irradiation on the number of broods were only observed among the F{sub 0}Daphnia exposed to 1000 and 10,000 mGy, whereas the brood size was equally affected in the two consecutive generations. In contrast, the F{sub 2} total fertility was compromised only among progeny of parents that received the highest dose of 10,000 mGy. We propose that the decreased fertility observed among the F{sub 2} progeny of parents exposed to 10,000 mGy is attributed to transgenerational effects of parental irradiation. Our results also indicate a substantial recovery of the F{sub 2} progeny of irradiated F{sub 0}Daphnia exposed to the lower doses of acute γ-rays. - Highlights: • Viability of irradiated daphnids and their F{sub 1} progeny is compromised. • Viability of the F{sub 2} progeny of irradiated parents is not affected. • Total fertility of irradiated daphnids and their F{sub 1} progeny declines with the dose. • Total fertility of the F{sub 2} progeny of parents exposed to 10,000 mGy is compromised. • The decreased fertility among the F{sub 2} progeny is transgenerational phenomenon.

  7. Quantifying murine bone marrow and blood radiation dose response following {sup 18}F-FDG PET with DNA damage biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Manning, Grainne [Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom); Taylor, Kristina [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, ON (Canada); Finnon, Paul [Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom); Lemon, Jennifer A.; Boreham, Douglas R. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, ON (Canada); Badie, Christophe, E-mail: christophe.badie@phe.gov.uk [Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom)

    2014-12-15

    Highlights: • Mice received either a range of {sup 18}F-FDG activities or whole body X-ray doses. • Blood samples were collected at 24 and 43 h for MN-RET and QPCR analysis. • Regression analysis showed that both types of exposure produced a linear response. • BM doses of 33 mGy ({sup 18}F-FDG) and 25 mGy X-rays were significantly higher than controls. • No significant difference between internal ({sup 18}F-FDG) and external (X-ray) was found. - Abstract: The purpose of this study was to quantify the poorly understood radiation doses to murine bone marrow and blood from whole-body fluorine 18 ({sup 18}F)-fluorodeoxyglucose (FDG) positron emission tomography (PET), by using specific biomarkers and comparing with whole body external low dose exposures. Groups of 3–5 mice were randomly assigned to 10 groups, each receiving either a different activity of {sup 18}F-FDG: 0–37 MBq or whole body irradiated with corresponding doses of 0–300 mGy X-rays. Blood samples were collected at 24 h and at 43 h for reticulocyte micronucleus assays and QPCR analysis of gene expression in peripheral blood leukocytes. Blood and bone marrow dose estimates were calculated from injected activities of {sup 18}F-FDG and were based on a recommended ICRP model. Doses to the bone marrow corresponding to 33.43 mGy and above for internal {sup 18}F-FDG exposure and to 25 mGy and above for external X-ray exposure, showed significant increases in radiation-induced MN-RET formation relative to controls (P < 0.05). Regression analysis showed that both types of exposure produced a linear response with linear regression analysis giving R{sup 2} of 0.992 and 0.999 for respectively internal and external exposure. No significant difference between the two data sets was found with a P-value of 0.493. In vivo gene expression dose–responses at 24 h for Bbc3 and Cdkn1 were similar for {sup 18}F-FDG and X-ray exposures, with significant modifications occurring for doses over 300 mGy for Bbc3

  8. Fetal shielding combined with state of the art CT dose reduction strategies during maternal chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Chatterson, Leslie C., E-mail: lch088@mail.usask.ca [Department of Diagnostic Imaging, University of Saskatchewan (Canada); Leswick, David A.; Fladeland, Derek A. [Department of Diagnostic Imaging, University of Saskatchewan (Canada); Hunt, Megan M.; Webster, Stephen [Saskatchewan Ministry of Labour Relations and Workplace Safety (Canada); Lim, Hyun [Department of Community Health and Epidemiology, College of Medicine, University of Saskatchewan (Canada)

    2014-07-15

    Purpose: Custom bismuth-antimony shields were previously shown to reduce fetal dose by 53% on an 8DR (detector row) CT scanner without dynamic adaptive section collimation (DASC), automatic tube current modulation (ATCM) or adaptive statistical iterative reconstruction (ASiR). The purpose of this study is to compare the effective maternal and average fetal organ dose reduction both with and without bismuth-antimony shields on a 64DR CT scanner using DASC, ATCM and ASiR during maternal CTPA. Materials and methods: A phantom with gravid prosthesis and a bismuth-antimony shield were used. Thermoluminescent dosimeters (TLDs) measured fetal radiation dose. The average fetal organ dose and effective maternal dose were determined using 100 kVp, scanning from the lung apices to the diaphragm utilizing DASC, ATCM and ASiR on a 64DR CT scanner with and without shielding in the first and third trimester. Isolated assessment of DASC was done via comparing a new 8DR scan without DASC to a similar scan on the 64DR with DASC. Results: Average third trimester unshielded fetal dose was reduced from 0.22 mGy ± 0.02 on the 8DR to 0.13 mGy ± 0.03 with the conservative 64DR protocol that included 30% ASiR, DASC and ATCM (42% reduction, P < 0.01). Use of a shield further reduced average third trimester fetal dose to 0.04 mGy ± 0.01 (69% reduction, P < 0.01). The average fetal organ dose reduction attributable to DASC alone was modest (6% reduction from 0.17 mGy ± 0.02 to 0.16 mGy ± 0.02, P = 0.014). First trimester fetal organ dose on the 8DR protocol was 0.07 mGy ± 0.03. This was reduced to 0.05 mGy ± 0.03 on the 64DR protocol without shielding (30% reduction, P = 0.009). Shields further reduced this dose to below accurately detectable levels. Effective maternal dose was reduced from 4.0 mSv on the 8DR to 2.5 mSv on the 64DR scanner using the conservative protocol (38% dose reduction). Conclusion: ASiR, ATCM and DASC combined significantly reduce effective maternal and fetal

  9. Fetal shielding combined with state of the art CT dose reduction strategies during maternal chest CT

    International Nuclear Information System (INIS)

    Chatterson, Leslie C.; Leswick, David A.; Fladeland, Derek A.; Hunt, Megan M.; Webster, Stephen; Lim, Hyun

    2014-01-01

    Purpose: Custom bismuth-antimony shields were previously shown to reduce fetal dose by 53% on an 8DR (detector row) CT scanner without dynamic adaptive section collimation (DASC), automatic tube current modulation (ATCM) or adaptive statistical iterative reconstruction (ASiR). The purpose of this study is to compare the effective maternal and average fetal organ dose reduction both with and without bismuth-antimony shields on a 64DR CT scanner using DASC, ATCM and ASiR during maternal CTPA. Materials and methods: A phantom with gravid prosthesis and a bismuth-antimony shield were used. Thermoluminescent dosimeters (TLDs) measured fetal radiation dose. The average fetal organ dose and effective maternal dose were determined using 100 kVp, scanning from the lung apices to the diaphragm utilizing DASC, ATCM and ASiR on a 64DR CT scanner with and without shielding in the first and third trimester. Isolated assessment of DASC was done via comparing a new 8DR scan without DASC to a similar scan on the 64DR with DASC. Results: Average third trimester unshielded fetal dose was reduced from 0.22 mGy ± 0.02 on the 8DR to 0.13 mGy ± 0.03 with the conservative 64DR protocol that included 30% ASiR, DASC and ATCM (42% reduction, P < 0.01). Use of a shield further reduced average third trimester fetal dose to 0.04 mGy ± 0.01 (69% reduction, P < 0.01). The average fetal organ dose reduction attributable to DASC alone was modest (6% reduction from 0.17 mGy ± 0.02 to 0.16 mGy ± 0.02, P = 0.014). First trimester fetal organ dose on the 8DR protocol was 0.07 mGy ± 0.03. This was reduced to 0.05 mGy ± 0.03 on the 64DR protocol without shielding (30% reduction, P = 0.009). Shields further reduced this dose to below accurately detectable levels. Effective maternal dose was reduced from 4.0 mSv on the 8DR to 2.5 mSv on the 64DR scanner using the conservative protocol (38% dose reduction). Conclusion: ASiR, ATCM and DASC combined significantly reduce effective maternal and fetal

  10. Investigation of lung nodule detectability in low-dose 320-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, J. D.; Paul, N. S.; Siewerdsen, J. H. [Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Imaging, Toronto General Hospital, Toronto, Ontario M5G 2C6 (Canada); Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Ontario Cancer Institute, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2009-05-15

    Low-dose imaging protocols in chest CT are important in the screening and surveillance of suspicious and indeterminate lung nodules. Techniques that maintain nodule detectability yet permit dose reduction, particularly for large body habitus, were investigated. The objective of this study was to determine the extent to which radiation dose can be minimized while maintaining diagnostic performance through knowledgeable selection of reconstruction techniques. A 320-slice volumetric CT scanner (Aquilion ONE, Toshiba Medical Systems) was used to scan an anthropomorphic phantom at doses ranging from {approx}0.1 mGy up to that typical of low-dose CT (LDCT, {approx}5 mGy) and diagnostic CT ({approx}10 mGy). Radiation dose was measured via Farmer chamber and MOSFET dosimetry. The phantom presented simulated nodules of varying size and contrast within a heterogeneous background, and chest thickness was varied through addition of tissue-equivalent bolus about the chest. Detectability of a small solid lung nodule (3.2 mm diameter, -37 HU, typically the smallest nodule of clinical significance in screening and surveillance) was evaluated as a function of dose, patient size, reconstruction filter, and slice thickness by means of nine-alternative forced-choice (9AFC) observer tests to quantify nodule detectability. For a given reconstruction filter, nodule detectability decreased sharply below a threshold dose level due to increased image noise, especially for large body size. However, nodule detectability could be maintained at lower doses through knowledgeable selection of (smoother) reconstruction filters. For large body habitus, optimal filter selection reduced the dose required for nodule detection by up to a factor of {approx}3 (from {approx}3.3 mGy for sharp filters to {approx}1.0 mGy for the optimal filter). The results indicate that radiation dose can be reduced below the current low-dose (5 mGy) and ultralow-dose (1 mGy) levels with knowledgeable selection of

  11. Penelitian Nilai Beban Pencemaran Pada Beberapa Ekstrak Zat Warna Alam

    Directory of Open Access Journals (Sweden)

    Kun Lestari

    2016-04-01

    Full Text Available Zat Pewarna Alam (ZWA akan direkomendasikan sebagai pewarna yang ramah baik bagi lingkungan maupun kesehatan, disebabkan karena kandungan komponen alaminya mempunyai nilai beban pencemaran yang rendah, mudah terdegradasi secara biologis dan tidak beracun. Pernyataan tersebut perlu diyakinkan kebenarannya. Telah dilakukan pengujian terhadap ekstrak pekat (0,75-1,00° Be dari 13 jenis sumber ZWA dari beberapa daerah di Indonesia yaitu: bakau, secang. sonokeling. bayam, markisa. bengkirai, nangka, pinus, kruing, kara benguk, tingi, tegeran dan mengkudu. Bahan pencemaran dinyatakan terhadap nilai BOD5, COD dan kandungan Fe (besi dalam ekstrak pekat yang telah tersimpan selama ±12 bulan. Dari hasil pengujian terlihat bahwa kadar BOD5 dan COD dari 13 jenis ekstrak ZWA mempunyai nilai 1700 mg/l. Tujuh jenis ekstrak ZWA yaitu ekstrak dari kayu nangka, kayu pinus. kayu kruing, kulit kara benguk, kulit kayu tingi, kayu tegeran dan akar mengkudu mempunyai nilai BOD5 dan COD 1000 mg/l, sedangkan ekstrak kulit batang bakau, kayu secang, kayu sonokeling, kayu buyam, kulit buah markisa dan kayu bengkirai mempunyai nilai BOD5 dan COD antara 1100 - 1700 mg/I. Dibandingkan dengan beban pencemaran yang diakibatkan oleh limbah cair pada pencelupan batik menggunakan zat warna sintetis (ZWS seperti Indigosol yang mempunyai nilai BOD5 = 3.053 mg/I, COD = 10.230 mg/I, dan Naphtol yang mempunyai nilai BOD5 = 5.411 mg/I, COD= 19.921 mg/I maka beban pencemaran ekstrak pekat ZWA masih jauh lebih kecil. Melihat perbandingan COD/BOD5 (=1,3-1,6, beban pencemaran ekstrak pekat ZWA dapat dikelompokkan ke dalam golongan air limbah rumah tangga (COD/BOD5 (2.Zat Pewarna Alam (ZWA akan direkomendasikan sebagai pewarna yang ramah baik bagi lingkungan maupun kesehatan, disebabkan karena kandungan komponen alaminya mempunyai nilai beban pencemaran yang rendah, mudah terdegradasi secara biologis dan tidak beracun. Pernyataan tersebut perlu diyakinkan kebenarannya. Telah dilakukan

  12. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    Energy Technology Data Exchange (ETDEWEB)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa [Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); Department of Neurosurgery, Division of Radiotherapy, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); CyberKnife Centre, Centro Diagnostico Italiano, 20147 Milano (Italy); Division of Medical Physics, Fondazione IRCCS, Istituto S. Raffaele, 20132 Milano (Italy); Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy)

    2010-07-15

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  13. Some experiences from radiation protection of patients undergoing X-ray examinations in Tanzania

    International Nuclear Information System (INIS)

    Ngaile, J.E.; Muhogora, W.E.; Nyanda, A.M.

    2001-01-01

    A study of patient entrance surface dose (ESD) received by adult patients was undertaken in five major diagnostic facilities in Tanzania. Five selected X-ray projections for chest PA; abdomen AP; lumbar spine AP; lumbar spine LAT and pelvis AP were done in the study. The mean ESDs after introduction of dose reduction methods were 0.34 mGy, 5.41 mGy, 3.7 mGy, 4.8 mGy and 8.8 mGy for chest PA; abdomen AP; pelvis AP; lumbar spine AP and lumbar spine LAT, respectively. The variations of doses observed in the study were influenced by performance characteristic of X-ray equipment, patient shape and size, type of image receptor, radiographic techniques as well as skills employed. The results show that increasing the tube voltage reduced the ESD by 35.5%, while lowering of mAs reduced ESD in the range from 15% to 60%. The reduction of ESD by increasing the filtration ranged from 11% to 58% while increasing of speed class of film-screen combination reduced the ESD in the range from 33% to 57%. The corresponding results of image quality show that out of 1064 scores of image criteria 298,481 and 285 were rated for good, satisfactory and poor respectively. The results of this study provide an evidence of existing potential for dose reduction in the diagnostic radiology facilities and the most important factor for improvement is to increase awareness, both from reality of harm from unnecessary radiation exposure and with relative ease doses can be reduced. The study should therefore be implemented on the national scale as an approach to establish guidance levels of patient entrance surface dose for good medical practice and regular monitoring purposes. (author)

  14. Radiation doses to patients receiving computed tomography examinations in British Columbia

    International Nuclear Information System (INIS)

    Aldrich, J.E.; Bilawich, A.-M.; Mayo, J.R.

    2006-01-01

    To estimate the diagnostic reference levels and effective radiation dose to patients from routine computed tomography (CT) examinations in the province of British Columbia, Canada. The patient weight, height and computed tomography dose index or dose linear product (DLP) were recorded on study sheets for 1070 patients who were referred for clinically indicated routine CT examinations at 18 radiology departments in British Columbia. Sixteen of the scanners were multidetector row scanners. The average patient dose varied from hospital to hospital. The largest range was found for CT of the abdomen, for which the dose varied from 3.6 to 26.5 (average 10.1) mSv. For head CT, the range was 1.7 to 4.9 (average 2.8) mSv; for chest CT, it was 3.8 to 26 (average 9.3) mSv; for pelvis CT, it was 3.5 to 15.5 (average 9.0) mSv; and for abdomen/pelvis CT, it was 7.3 to 31.5 (average 16.3) mSv. Reference dose values were calculated for each exam. These DLP values are as follows: head, 1300 mGy cm; chest, 600 mGy cm; abdomen, 920 mGy cm; pelvis, 650 mGy cm; and abdomen/pelvis, 1100 mGy cm. Among hospitals, there was considerable variation in the DLP and patient radiation dose for a specific exam. Reference doses and patient doses were higher than those found in similar recent surveys carried out in the United Kingdom and the European Union. Patient doses were similar to those found in a recent survey in Germany. (author)

  15. Assessment of medical radiation exposure to patients and ambient doses in several diagnostic radiology departments

    Science.gov (United States)

    Sulieman, A.; Elhadi, T.; Babikir, E.; Alkhorayef, M.; Alnaaimi, M.; Alduaij, M.; Bradley, D. A.

    2017-11-01

    In many countries diagnostic medical exposures typically account for a very large fraction of the collective effective dose that can be assigned to anthropological sources and activities. This in part flags up the question of whether sufficient steps are being taken in regard to potential dose saving from such medical services. As a first step, one needs to survey doses to compare against those of best practice. The present study has sought evaluation of the radiation protection status and patient doses for certain key radiological procedures in four film-based radiology departments within Sudan. The radiation exposure survey, carried out using a survey meter and quality control test tools, involved a total of 299 patients their examinations being carried out at one or other of these four departments. The entrance surface air kerma (ESAK) was determined from exposure settings using DosCal software and an Unfors -Xi-meter. The mean ESAK for x-ray examination of the chest was 0.30±0.1 mGy, for the skull it was 0.96±0.7 mGy, for the abdomen 0.85±0.01 mGy, for spinal procedures 1.30±0.6 mGy and for procedures involving the limbs it was 0.43±0.3 mGy. Ambient dose-rates in the reception area, at the closed door of the x-ray room, recorded instantaneous values of up to 100 μSv/h. In regard to protection, the associated levels were found to be acceptable in three of the four departments, corrective action being required for one department, regular quality control also being recommended.

  16. Entrance surface dose and image quality: Comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia

    International Nuclear Information System (INIS)

    Hambali, A. S.; Ng, K. H.; Abdullah, B. J. J.; Wang, H. B.; Jamal, N.; Spelic, D. C.; Suleiman, O. H.

    2009-01-01

    This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia. (authors)

  17. Attainment of dosimetric pediatrics grandeur to computed tomography examinations of the abdomen

    International Nuclear Information System (INIS)

    Jormada, Tiago S.

    2013-01-01

    Currently, 10% of all computerized tomography exams (CT) are made in pediatric patients. In developed countries, the practice of obtaining the dosimetric quantities (weighted index dose C w , index air kerma volumetric C vol product kerma-length P KL , CT ) and effective dose (E) in pediatric CT scans is common. In Brazil, data like these are practically nonexistent. The goal of this work is to obtain the dosimetric quantities and the dose effective in pediatric CT scans, and study its application in the optimization process. The study took place in a thermographs' Toshiba Asteion Single-Slice and a GE Brightsped's multi-slice where measurements were made with type pencil ionization chamber and a trunk's phantom of PMMA with diameter of 16 cm. In single-slice CT scanner, the results obtained for the C vol , P KL , CT and E were 18.73 mGy, 15.61 mGy and 6.87 mSv mGy.cm 343.51, respectively, whereas in multi-slice CT scanner the results were 18.81 mGy, 20.07 mGy, 441.64 mGy.cm and 8,83 mSv. There was no significant difference between the values of C w obtained already in the values of the Cvol, P KL , CT and E dose the differences between the results were quite significant. Comparing the C w and P KL , CT and with the values recommended by UCRP 87 (25 mGy for C vol and 360 mGy.cm for P KL , CT in pediatric CT scans of the abdomen), the two scanners were below reference levels for C w and not require an start on process of optimization. (author)

  18. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  19. EPR dosimetry of radiation background in the Urals region

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A.; Degteva, M.O.; Shved, V.A. [Urals Research Center for Radiation Medicine, 48-A Vorovsky, Chelyabinsk 454076 (Russian Federation); Fattibene, P.; Onori, S. [Istituto Superiore di Sanita and Istituto Nazionale di Fisica Nucleare (Italy); Wieser, A. [GSF, Forschungszentrum fuer Umwelt und Gesundheit, Ingolstaedter Landstr (Germany); Ivanov, D.V.; Bayankin, S.N. [Institute of Metal Physics, Russian Academy of Sciences (Russian Federation); Knyazev, V.A.; Vasilenko, E.I.; Gorelov, M. [ZAO, Closed Corporation ' Company GEOSPETSECOLOGIA' (Russian Federation)

    2006-07-01

    Method of Electron Paramagnetic Resonance is extensively applied to individual retrospective dosimetry. The background dose is unavoidable component of cumulative absorbed dose in the tooth enamel accumulated during the lifetime of donor. Estimation of incidental radiation dose using tooth enamel needs in extraction of background dose. Moreover, the variation of background doses in the population is a limited factor for reliable detection of additional irradiation especially for low dose level. Therefore the accurate knowledge of the natural background radiation dose is a critical element of EPR studies of exposed populations. In the Urals region the method applies for such two large cohorts as the workers of Mayak (Ozersk citizens) and Techa River riverside inhabitants (rural population). Current study aimed to investigate the Urals radiation background detected by EPR spectrometry. For this aim two group of unexposed Urals residents were separated, viz: citizens of Ozersk and rural inhabitants of Chelyabinsk region. Comparison of two investigated territories has demonstrated that from the point of view of radiation background it is impossible to assume the Urals population as uniform. The reliable difference between the urban and rural residents has been found. The average background doses of Ozersk donors is in average 50 mGy higher than those detected for rural residents. The individual variability of background doses for Osersk has been higher than in the rural results. The difference in background dose levels between two population results in different limits of accidental dose detection and individualization. The doses for 'Mayak' workers (Ozyorsk citizens) can be classed as anthropogenic if the EPR measurements exceed 120 mGy for teeth younger than 40 years, and 240 mGy for teeth older than 70 years. The anthropogenic doses for Techa River residents (rural population) would be higher than 95 mGy for teeth younger than 50 years and 270 mGy for

  20. Parotid-Absorbed Doses: A Comparison Between Spiral Tomography and Panoramic

    Directory of Open Access Journals (Sweden)

    Ehsan Hekmatian

    2016-07-01

    Full Text Available Background Jaws spiral tomography and panoramic radiography have wide applications in dentistry, and the parotid gland is one of the most sensitive organs of the head and neck. Objectives The aim of this study was to evaluate and compare the parotid-absorbed dose in spiral tomography and panoramic radiographs using a thermoluminescent dosimeter. Materials and Methods A radiation analog dosimetry phantom was placed in a Cranex Tome radiograph device, and a parotid absorbed dose was measured in both techniques. Thermoluminescent dosimeters were placed bilaterally in the parotid region (on the tube side and the opposite side. Spiral tomography dosimetry was done for the upper and lower jaws in the anterior and posterior regions. Each region contained four slices of 2 mm and four slices of 4 mm in thickness. The results were analyzed by a Wilcoxon test. Results For the tube side parotid, the average absorbed doses in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.70/1.40 and 1.65/1.60 mGy, respectively. The average absorbed doses with the 4mm slices were 1.65/1.70 and 1.75/1.57 mGy, respectively. For the opposite parotid, the average absorbed dose in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.40/1.30 and 1.40/1.67 mGy, respectively. The average absorbed doses with the 4mm slices were 1.50/1.66 and 1.40/1.50 mGy, respectively. The average absorbed dose of the panoramic radiograph was 1.40 mGy. Conclusions There was no statistically significant difference in the parotid absorbed dose between spiral tomography and a panoramic radiograph (P value = 0.18. The overall results of this study were similar to other studies.

  1. Evidence for radiation induced crosslinking in polytetrafluoroethylene by means of high-resolution solid-state 19F high-speed MAS NMR

    International Nuclear Information System (INIS)

    Katoh, Etsuko; Sugisawa, Hisashi; Oshima, Akihiro; Tabata, Yoneho; Seguchi, Tadao; Yamazaki, Toshimasa

    1999-01-01

    Radiation effects on molecular structure of polytetrafluoroethylene (PTFE) were studied by high-resolution solid-state 19 F high speed magic angle spinning (HS MAS) NMR spectroscopy. Samples used for the NMR studies were prepared by electron beam irradiation of PTFE with a wide range of irradiation doses from 0.5-10 MGy in the molten state at 340 deg. C under oxygen-free atmosphere. While the non-irradiated PTFE displayed only an intense peak of the internal CF 2 , several new signals corresponding to CF 3 , CF 2 and CF groups were observed for the PTFE which was high temperature irradiated at 340 deg. C in oxygen-free atmosphere (hti-PTFE). Intensities of these new signals increased with an increase of irradiation dose. The present solid-state 19 F HS MAS NMR studies provide not only the first experimental evidence regarding the existence of crosslinking structure in hti-PTFE, directly detected as the CF signal, but also the crosslinking density which can be estimated from a proportion of the CF versus total fluorine signal intensities. The higher the irradiation dose, the higher the crosslinking density; hti-PTFE with 10 MGy contains one crosslinking site per approximately 24 CF 2 groups, while the hti-PTFE with 5 MGy contains one crosslinking site per approximately 36 CF 2 groups. Further, G value of crosslinking (G(x)) was estimated from the signal intensities of 19 F HS MAS NMR spectra. The highest G(x)-value, 1.85, was observed for the 2MGy hti-PTFE sample, suggesting that crosslinking of PTFE is formed most efficaciously with 2 MGy irradiation in the molten state at 340 deg. C under oxygen-free atmosphere

  2. Combined effects of alpha particles and depleted uranium on Zebrafish (Danio rerio) embryos

    International Nuclear Information System (INIS)

    Ng, Candy Y.P.; Pereira, Sandrine; Cheng, Shuk Han; Adam-Guillermin, Christelle; Garnier-Laplace, Jacqueline; Yu, Kwan Ngok

    2016-01-01

    The combined effects of low-dose or high-dose alpha particles and depleted uranium (DU) in Zebrafish (Danio rerio) embryos were studied. Three schemes were examined—(i) [I L U L ]: 0.44 mGy alpha-particle dose + 10 µg/l DU exposure, (ii) [I H U H ]: 4.4 mGy alpha-particle dose + 100 µg/l DU exposure and (iii) [I H U L ]: 4.4 mGy alpha-particle dose + 10 µg/l DU exposure—in which Zebrafish embryos were irradiated with alpha particles at 5 h post fertilization (hpf) and/or exposed to uranium at 5–6 hpf. The results were also compared with our previous work, which studied the effects of [I L U H ]: 0.44 mGy alpha-particle dose + 100 µg/l DU exposure. When the Zebrafish embryos developed to 24 hpf, the apoptotic signals in the entire embryos, used as the biological endpoint for this study, were quantified. Our results showed that [I L U L ] and [I H U L ] led to antagonistic effects, whereas [I H U H ] led to an additive effect. The effect found for the previously studied case of [I L U H ] was difficult to define because it was synergistic with reference to the 100 µg/l DU exposure, but it was antagonistic with reference to the 0.44 mGy alpha-particle dose. All the findings regarding the four different schemes showed that the combined effects critically depended on the dose response to each individual stressor. We also qualitatively explained these findings in terms of promotion of early death of cells predisposed to spontaneous transformation by alpha particles, interacting with the delay in cell death resulting from various concentrations of DU exposure

  3. Effect of continuous exposure to very low dose rates of gamma rays on life span and neoplasia in mice

    International Nuclear Information System (INIS)

    Tanaka, I.B. III; Tanaka, Satoshi; Ichinohe, Kazuaki; Matsumoto, Tsuneya; Otsu, Hiroshi; Oghiso, Yoichi; Sato, Fumiaki; Matsushita, Satoru

    2008-01-01

    Late effects of continuous exposure to ionizing radiation are potential hazards to workers in radiation facilities as well as to the general public. In the recent years, low-dose-rate and low-dose effects have become a serious concern. Using a total of 4,000 mice, we studied the late biological effects of chronic exposure to low-dose-rate radiation on life span and neoplasia. Two thousand male and 2000 female 8-week-old specific pathogen free (SPF) B6C3F1 mice were randomly divided into 4 groups, one non-irradiated (control) and three irradiated. The irradiated groups were exposed to 137 Cs gamma rays at dose-rates of 21, 1.1 and 0.05 mGy day -1 for approximately 400 days with total doses equivalent to 8000, 400 and 20 mGy, respectively. All mice were kept under SPF conditions until natural death and pathological examination was performed to determine the cause of death. Statistical analyses showed that the life spans of mice of both sexes irradiated with 21 mGy day -1 (P -1 (P 86.7% of all deaths. Compared to the non-irradiated controls, incidences of lethal neoplasms were significantly increased for myeloid leukaemia and hemangiosarcoma in males, soft tissue neoplasms and malignant granulosa cell tumors in females exposed to 21 mGy day -1 . The number of multiple primary neoplasms per mouse was significantly increased in mice irradiated at 21 mGy day -1 . Our results suggest that life shortening in mice continuously exposed to low dose-rate gamma rays is due to early death from a variety of neoplasms and not from increased incidence of specific lethal neoplasms. (author)

  4. Improving anxiety regulation in patients with breast cancer at the beginning of the survivorship period: a randomized clinical trial comparing the benefits of single-component and multiple-component group interventions.

    Science.gov (United States)

    Merckaert, Isabelle; Lewis, Florence; Delevallez, France; Herman, Sophie; Caillier, Marie; Delvaux, Nicole; Libert, Yves; Liénard, Aurore; Nogaret, Jean-Marie; Ogez, David; Scalliet, Pierre; Slachmuylder, Jean-Louis; Van Houtte, Paul; Razavi, Darius

    2017-08-01

    To compare in a multicenter randomized controlled trial the benefits in terms of anxiety regulation of a 15-session single-component group intervention (SGI) based on support with those of a 15-session multiple-component structured manualized group intervention (MGI) combining support with cognitive-behavioral and hypnosis components. Patients with nonmetastatic breast cancer were randomly assigned at the beginning of the survivorship period to the SGI (n = 83) or MGI (n = 87). Anxiety regulation was assessed, before and after group interventions, through an anxiety regulation task designed to assess their ability to regulate anxiety psychologically (anxiety levels) and physiologically (heart rates). Questionnaires were used to assess psychological distress, everyday anxiety regulation, and fear of recurrence. Group allocation was computer generated and concealed till baseline completion. Compared with patients in the SGI group (n = 77), patients attending the MGI group (n = 82) showed significantly reduced anxiety after a self-relaxation exercise (P = .006) and after exposure to anxiety triggers (P = .013) and reduced heart rates at different time points throughout the task (P = .001 to P = .047). The MGI participants also reported better everyday anxiety regulation (P = .005), greater use of fear of recurrence-related coping strategies (P = .022), and greater reduction in fear of recurrence-related psychological distress (P = .017) compared with the SGI group. This study shows that an MGI combining support with cognitive-behavioral techniques and hypnosis is more effective than an SGI based only on support in improving anxiety regulation in patients with breast cancer. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Estimation of effective dose during hysterosalpingography procedures; Estimación de dosis efectiva durante los procedimientos hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M. [King Saud University, College of Applied Medical Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433, (Saudi Arabia); Sulieman, A. [Salman bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj (Saudi Arabia); Alsafi, K. [King Abdulaziz University, Faculty of Medicine, Radiology Department, Jeddah 22254 (Saudi Arabia); Omer, H., E-mail: kalzimami@ksu.edu.sa [Dammam University, Faculty of Medicine, Dammam Khobar Coastal Rd, Khobar 31982 (Saudi Arabia)

    2014-08-15

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  6. Non-induction of radioadaptive response in zebrafish embryos by neutrons

    International Nuclear Information System (INIS)

    Ng, Candy Y.P.; Kong, Eva Y.; Kobayashi, Alisa; Suya, Noriyoshi; Uchihori, Yukio; Cheng, Shuk Han; Konishi, Teruaki; Yu, Kwan Ngok

    2016-01-01

    In vivo neutron-induced radioadaptive response (RAR) was studied using zebrafish (Danio rerio) embryos. The Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility at the National Institute of Radiological Sciences (NIRS), Japan, was employed to provide 2-MeV neutrons. Neutron doses of 0.6, 1, 25, 50 and 100 mGy were chosen as priming doses. An X-ray dose of 2 Gy was chosen as the challenging dose. Zebrafish embryos were dechorionated at 4 h post fertilization (hpf), irradiated with a chosen neutron dose at 5 hpf and the X-ray dose at 10 hpf. The responses of embryos were assessed at 25 hpf through the number of apoptotic signals. None of the neutron doses studied could induce RAR. Non-induction of RAR in embryos having received 0.6- and 1-mGy neutron doses was attributed to neutron-induced hormesis, which maintained the number of damaged cells at below the threshold for RAR induction. On the other hand, non-induction of RAR in embryos having received 25-, 50- and 100-mGy neutron doses was explained by gamma-ray hormesis, which mitigated neutron-induced damages through triggering high-fidelity DNA repair and removal of aberrant cells through apoptosis. Separate experimental results were obtained to verify that high-energy photons could disable RAR. Specifically, 5- or 10-mGy X-rays disabled the RAR induced by a priming dose of 0.88 mGy of alpha particles delivered to 5-hpf zebrafish embryos against a challenging dose of 2 Gy of X-rays delivered to the embryos at 10 hpf

  7. Compression force and radiation dose in the Norwegian Breast Cancer Screening Program

    Energy Technology Data Exchange (ETDEWEB)

    Waade, Gunvor G.; Sanderud, Audun [Department of Life Sciences and Health, Faculty of Health Sciences, Oslo and Akershus University College of Applied Sciences, P.O. 4 St. Olavs Plass, 0130 Oslo (Norway); Hofvind, Solveig, E-mail: solveig.hofvind@kreftregisteret.no [Department of Life Sciences and Health, Faculty of Health Sciences, Oslo and Akershus University College of Applied Sciences, P.O. 4 St. Olavs Plass, 0130 Oslo (Norway); The Cancer Registry of Norway, P.O. 5313 Majorstuen, 0304 Oslo (Norway)

    2017-03-15

    Highlights: • Compression force and radiation dose for 17 951 screening mammograms were analyzed. • Large variations in mean applied compression force between the breast centers. • Limited associations between compression force and radiation dose. - Abstract: Purpose: Compression force is used in mammography to reduce breast thickness and by that decrease radiation dose and improve image quality. There are no evidence-based recommendations regarding the optimal compression force. We analyzed compression force and radiation dose between screening centers in the Norwegian Breast Cancer Screening Program (NBCSP), as a first step towards establishing evidence-based recommendations for compression force. Materials and methods: The study included information from 17 951 randomly selected screening examinations among women screened with equipment from four different venors at fourteen breast centers in the NBCSP, January-March 2014. We analyzed the applied compression force and radiation dose used on craniocaudal (CC) and mediolateral-oblique (MLO) view on left breast, by breast centers and vendors. Results: Mean compression force used in the screening program was 116N (CC: 108N, MLO: 125N). The maximum difference in mean compression force between the centers was 63N for CC and 57N for MLO. Mean radiation dose for each image was 1.09 mGy (CC: 1.04mGy, MLO: 1.14mGy), varying from 0.55 mGy to 1.31 mGy between the centers. Compression force alone had a negligible impact on radiation dose (r{sup 2} = 0.8%, p = < 0.001). Conclusion: We observed substantial variations in mean compression forces between the breast centers. Breast characteristics and differences in automated exposure control between vendors might explain the low association between compression force and radiation dose. Further knowledge about different automated exposure controls and the impact of compression force on dose and image quality is needed to establish individualised and evidence

  8. Optimal conditions of LDR to protect the kidney from diabetes

    Science.gov (United States)

    Cheng, Jie; Li, Fengsheng; Cui, Jiuwei; Guo, Weiying; Li, Cai; Li, Wei; Wang, Guixia; Xing, Xiao; Gao, Ying; Ge, Yuanyuan; Wang, Guanjun; Cai, Lu

    2014-01-01

    Aims We reported the attenuation of diabetes-induced renal dysfunction by exposure to multiple low-dose radiation (LDR) at 25 mGy every other day via suppressing renal oxidative damage. We here explored the optimal conditions of LDR to protect the kidney from diabetes. Main methods Type 1 diabetic mice were induced with multiple injections of low-dose streptozotocin in male C57BL/6J mice. Diabetic mice received whole body X-irradiation at dose of 12.5, 25 or 50 mGy every other day for either 4 or 8 weeks. Age-matched normal mice were similarly irradiated at the dose of 25 mGy for 4 or 8 weeks. The renal function and histopathological changes were examined at the 4th and 8th week of the study. Key findings Diabetes induced renal dysfunction, shown by the decreased creatinine and increased microalbumin in urinary. Renal oxidative damage, detected by protein nitration and lipid oxidation, and remodeling, reflected by increased expression of connective tissue growth factor, collagen IV and fibronectin, were significantly increased in diabetic mice. All these renal pathological and function changes in diabetic mice were significantly attenuated by exposure to LDR at all regimens, among which, however, exposure to LDR at 12.5 mGy for 8 weeks provided the best preventive effect on the kidney of diabetic mice. Significance Our results suggest that whole-body LDR at 12.5 mGy every other day for 8 weeks is the optimal condition of LDR to protect the kidney from diabetes. PMID:24631139

  9. Estimation of mean glandular dose for patients who undergo mammography and studying the factors affecting it

    Science.gov (United States)

    Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury

    2017-09-01

    The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.

  10. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    International Nuclear Information System (INIS)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa

    2010-01-01

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  11. Patient dose in CT fluoroscopy examinations

    International Nuclear Information System (INIS)

    Ito, Yusuke; Kobayashi, Masanao; Kataoka, Yumi; Ida, Yoshihiro; Kato, Ryoichi; Katada, Kazuhiro; Asada, Yasuki; Suzuki, Shoichi

    2008-01-01

    CT fluoroscopy(CTF) results in a high dose for the area under investigation in comparison with other types of examination. On the basis of data from April 2005 to March 2008, we measured the X-ray doses at the target site in CTF of the lungs, lumbar vertebrae, and pelvis as well as the X-ray dose to the female reproductive organs, and calculated the effective dose. The CT equipment used was an Aquilion 16. TLDs were inserted into an anthropomorphic phantom in positions corresponding to the target sites and the reproductive organs. Standard tube voltage and tube current were used as measurement conditions, and the scanning time used was the average value for each type of examination during the two years. Dose measurements were taken in the following order: scanography, helical scan, CTF, helical scan. X-ray element calibration was carried out through reciprocal comparison made between an ionization chamber dosimeter corrected according to government standards and the TLD for each tube voltage used for measurement. Dose estimation software was used to calculate the effective doses. During the two years there were 136 CTF examinations. These included 43 scans of the lungs, 13 of lumbar vertebrae, and 18 of the pelvis. The X-ray doses were 0.1 mGy at both the ovaries and the uterus for lung scans, 2 mGy at the ovaries and 1 mGy at the uterus for lumbar vertebrae scans, and 40 mGy at the ovaries and 20 mGy at the uterus for pelvic scans. The effective dose was highest for the lumbar vertebrae, followed by the lungs and finally the pelvis. (author)

  12. SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, X; Yang, K; Liu, B [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length was used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.

  13. The effects of rat's sperm bioassay for low dose X-ray

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Gye Hwan; Min, Soo Young; Lee, Sang Bock; Lee, Sam Yul; Lee, Jun Haeng [Nambu Univ., Gwangju (Korea, Republic of); Park, Jong Bae [Juseong College, Cheongwon (Korea, Republic of)

    2007-12-15

    In order to investigate the enhancement effects of low dose radiation on biological activation, this study applied low dose X-ray to the whole body of male rats to find out whether hormesis is induced in male germ cells. Total 36 Sprague-Dawley (SD) rats as experimental animal were subdivided into 6 groups(in 6 rats per group) such as control, 10 mGy, 20 mGy, 50 mGy, 100 mGy and 200 mGy radiation group. All the groups showed slightly increasing number of sperms per 0.1 g semen (14.216 x 10{sup 6}, 13.901 x 10{sup 6}, 14.153 x 10{sup 6}, 13.831 x 10{sup 6}, 14.137 x 10{sup 6}, 14.677 x 10{sup 6} respectively), and the motility of sperms amounted to 50.9%, 49.5%, 55.1%, 54.3%, 48.0% and 52.2% respectively. Particularly, compared to the control, the other 5 groups showed higher male hormone level, and the microscopic observations of testicle tissues showed no vacuolization in seminiferous tubules and testis cells. In the results of this experiment, no harmful effect was observed on Sprague-Dawley (SD) rats for which the dose of radiation was controlled as regulated legally by the Ministry of Science and Technology and the Ministry of Health and Welfare. However, as these results were obtained from a limited number of animals, we cannot maintain that the same effect will be observed in the human body. Therefore, there should be further research on the effect on other animals and ultimately on the human body.

  14. Evaluation of thyroid function in female subjects living in the high natural background radiation area of Karunagappally, Kerala

    International Nuclear Information System (INIS)

    Sreekumar, A.; Nair, Raghu Ram K.; Jayalakshmi, P.; Sebastian, P.; Akiba, S.

    2010-01-01

    Radiation exposure has been reported to cause non cancer thyroid abnormalities like diffuse goiter and thyroid nodules. The present study was undertaken to see if there are any morphological and functional changes taking place in the thyroid due to chronic low level radiation exposure. 257 female subjects living in the four high background radiation panchayats of Chavara, Neendakara, Alappad and Panmana were selected for the study after getting informed consent. 5 ml of blood was drawn from these subjects for assessing thyroid function. The subjects were all staying in the same area since their birth and had not moved out for more than one year at a stretch. The average age of the subjects was 40.5y with a range of 17-66y. The cumulative dose had a mean of 226.3 mGy and a range of 20.6-937.8 mGy. 95 subjects from the low background area of Oachira and Thevalakkara were selected as controls in the age group of 18-63y with a mean age of 47.1y. The mean cumulative dose of this group was 35.9 mGy with a minimum of 5.3 mGy and a maximum of 106.8 mGy. 5 ml blood was collected from these subjects for thyroid function studies. All the subjects underwent ultrasound examination of the thyroid using a 10 MHz frequency linear probe. The following parameters were studied to assess thyroid function: Free T4, TSH, Antithyroglobulin antibody (ATG), Parathyroid hormone. Ultrasound images showed the following common features: Normal - 171, Suggestive of Thyroiditis - 106, Multinodular Goitre - 63, Diffuse Goitre - 5, Solitary Nodule - 31. 73 subjects had elevated TSH and 190 subjects had raised ATG. A significant numbers of subjects had features of thyroiditis. A comparative evaluation with control subjects will be done to assess its significance with reference to cumulative dose

  15. The effects of rat's sperm bioassay for low dose X-ray

    International Nuclear Information System (INIS)

    Jin, Gye Hwan; Min, Soo Young; Lee, Sang Bock; Lee, Sam Yul; Lee, Jun Haeng; Park, Jong Bae

    2007-01-01

    In order to investigate the enhancement effects of low dose radiation on biological activation, this study applied low dose X-ray to the whole body of male rats to find out whether hormesis is induced in male germ cells. Total 36 Sprague-Dawley (SD) rats as experimental animal were subdivided into 6 groups(in 6 rats per group) such as control, 10 mGy, 20 mGy, 50 mGy, 100 mGy and 200 mGy radiation group. All the groups showed slightly increasing number of sperms per 0.1 g semen (14.216 x 10 6 , 13.901 x 10 6 , 14.153 x 10 6 , 13.831 x 10 6 , 14.137 x 10 6 , 14.677 x 10 6 respectively), and the motility of sperms amounted to 50.9%, 49.5%, 55.1%, 54.3%, 48.0% and 52.2% respectively. Particularly, compared to the control, the other 5 groups showed higher male hormone level, and the microscopic observations of testicle tissues showed no vacuolization in seminiferous tubules and testis cells. In the results of this experiment, no harmful effect was observed on Sprague-Dawley (SD) rats for which the dose of radiation was controlled as regulated legally by the Ministry of Science and Technology and the Ministry of Health and Welfare. However, as these results were obtained from a limited number of animals, we cannot maintain that the same effect will be observed in the human body. Therefore, there should be further research on the effect on other animals and ultimately on the human body

  16. Diagnostic accuracy at several reduced radiation dose levels for CT imaging in the diagnosis of appendicitis

    Science.gov (United States)

    Zhang, Di; Khatonabadi, Maryam; Kim, Hyun; Jude, Matilda; Zaragoza, Edward; Lee, Margaret; Patel, Maitraya; Poon, Cheryce; Douek, Michael; Andrews-Tang, Denise; Doepke, Laura; McNitt-Gray, Shawn; Cagnon, Chris; DeMarco, John; McNitt-Gray, Michael

    2012-03-01

    Purpose: While several studies have investigated the tradeoffs between radiation dose and image quality (noise) in CT imaging, the purpose of this study was to take this analysis a step further by investigating the tradeoffs between patient radiation dose (including organ dose) and diagnostic accuracy in diagnosis of appendicitis using CT. Methods: This study was IRB approved and utilized data from 20 patients who underwent clinical CT exams for indications of appendicitis. Medical record review established true diagnosis of appendicitis, with 10 positives and 10 negatives. A validated software tool used raw projection data from each scan to create simulated images at lower dose levels (70%, 50%, 30%, 20% of original). An observer study was performed with 6 radiologists reviewing each case at each dose level in random order over several sessions. Readers assessed image quality and provided confidence in their diagnosis of appendicitis, each on a 5 point scale. Liver doses at each case and each dose level were estimated using Monte Carlo simulation based methods. Results: Overall diagnostic accuracy varies across dose levels: 92%, 93%, 91%, 90% and 90% across the 100%, 70%, 50%, 30% and 20% dose levels respectively. And it is 93%, 95%, 88%, 90% and 90% across the 13.5-22mGy, 9.6-13.5mGy, 6.4-9.6mGy, 4-6.4mGy, and 2-4mGy liver dose ranges respectively. Only 4 out of 600 observations were rated "unacceptable" for image quality. Conclusion: The results from this pilot study indicate that the diagnostic accuracy does not change dramatically even at significantly reduced radiation dose.

  17. EPR dosimetry of radiation background in the Urals region

    International Nuclear Information System (INIS)

    Shishkina, E.A.; Degteva, M.O.; Shved, V.A.; Fattibene, P.; Onori, S.; Wieser, A.; Ivanov, D.V.; Bayankin, S.N.; Knyazev, V.A.; Vasilenko, E.I.; Gorelov, M.

    2006-01-01

    Method of Electron Paramagnetic Resonance is extensively applied to individual retrospective dosimetry. The background dose is unavoidable component of cumulative absorbed dose in the tooth enamel accumulated during the lifetime of donor. Estimation of incidental radiation dose using tooth enamel needs in extraction of background dose. Moreover, the variation of background doses in the population is a limited factor for reliable detection of additional irradiation especially for low dose level. Therefore the accurate knowledge of the natural background radiation dose is a critical element of EPR studies of exposed populations. In the Urals region the method applies for such two large cohorts as the workers of Mayak (Ozersk citizens) and Techa River riverside inhabitants (rural population). Current study aimed to investigate the Urals radiation background detected by EPR spectrometry. For this aim two group of unexposed Urals residents were separated, viz: citizens of Ozersk and rural inhabitants of Chelyabinsk region. Comparison of two investigated territories has demonstrated that from the point of view of radiation background it is impossible to assume the Urals population as uniform. The reliable difference between the urban and rural residents has been found. The average background doses of Ozersk donors is in average 50 mGy higher than those detected for rural residents. The individual variability of background doses for Osersk has been higher than in the rural results. The difference in background dose levels between two population results in different limits of accidental dose detection and individualization. The doses for 'Mayak' workers (Ozyorsk citizens) can be classed as anthropogenic if the EPR measurements exceed 120 mGy for teeth younger than 40 years, and 240 mGy for teeth older than 70 years. The anthropogenic doses for Techa River residents (rural population) would be higher than 95 mGy for teeth younger than 50 years and 270 mGy for teeth older

  18. DVOJNA OBDAVČITEV DOHODKOV V EU IN V SLOVENIJI IN NJEN VPLIV NA MIGRACIJSKE TOKOVE

    OpenAIRE

    Smrečnik, Sabina

    2017-01-01

    Vse več ljudi se zaradi vedno lažjega načina selitev in osebnih ali kakršnih koli drugih razlogov odloča, da se preselijo v drugo državo. Pri tem se soočajo z različnimi težavami, drugačno kulturo, tujim jezikom, spremenjenim načinom življenja in tudi z ureditvijo rezidentstva ter dvojnimi davki. Migracije poznamo že iz zgodovine. Ljudje so se zaradi najrazličnejših vzrokov preseljevali. Tudi danes se veliko selimo, naj gre le za vsakodnevne migracije iz kraja v kraj oziroma med bližnjimi ...

  19. In memoriam 2002

    Index Scriptorium Estoniae

    2003-01-01

    Maailm: Kenneth Armitage (18. VII 1916-22. I), Eduardo Chillida (10. I 1924-19. VIII), Ruth Handler (4. IV 1916-27. IV), Yousuf Karsh (23. XII 1908-14. VII), Roberto Matta (11. XI 1911-23. XI). Eesti: Endel Kaldmäe (12. VII 1918-15. XII), Tiia Kelomees-Johannson (8. IX 1965-11. VI), Salme Kirsimäe (6. XI 1919-1. IV), Maret Kuke (9. X 1926-2. VII), Diana Laev (21. XI 1919-31. VIII), Pauline Leps (16. XI 1903-5. III), Avo-Himm Looveer (16. VIII 1941- 1. V), Jüri Palm (14. IV 1937-27. IV), Agu Pilt (26. VIII 1951-11. III), Valve Pormeister (13. IV 1922-27. X), Eugen Sacharias (21. IV 1906-13. III), Lilian Schönberg (25. IV 1934-10. X), Laine Sisa (12. II 1931-20. II)

  20. Mud-filtrate correction of sonic logs by fluid substitution

    DEFF Research Database (Denmark)

    Sørensen, Morten Kanne

    structures. Making reliable discoveries in challenging conditions requires an increasing level of detail in seismic interpretation. Advanced seismic processing as Amplitude-Versus-Offset (AVO) analysis, have become commonplace in seismic interpretation. These techniques involves comparison with synthetic...... of wetting phase saturation, and the clay content. When the water saturation is at the irreducible water saturation or higher only the effect of clay on the elastic velocities have a differential effect on the elastic velocities. Mixed saturations are fluid substituted using effective fluid moduli formulated...... as a set of bounds by Mavko and Mukerji (1998). Ultrasonic velocity data from the literature shows that these bounds applies most accurately to sandstones with a simple pore-space, as reflected in a high permeability and low clay fraction....

  1. Environmental Monitoring Plan, Nevada Test Site and support facilities

    International Nuclear Information System (INIS)

    1991-11-01

    This Operational Area Monitoring Plan for environmental monitoring, is for EG ampersand G Energy Measurements, Inc. (EG ampersand G/EM) which operates several offsite facilities in support of activities at the Nevada Test Site (NTS). These facilities include: (1) Amador Valley Operations (AVO), Pleasanton, California; (2) Kirtland Operations (KO), Kirtland Air Force base, Albuquerque, New Mexico (KAFB); (3) Las Vegas Area Operations (LVAO), Remote Sensing Laboratory (RSL), and North Las Vegas (NLV) Complex at Nellis Air Force Base (NAFB), North Las Vegas, Nevada; (4) Los Alamos Operations (LAO), Los Alamos, New Mexico; (5) Santa Barbara Operations (SBO), Goleta, California; (6) Special Technologies Laboratory (STL), Santa Barbara, California; (7) Washington Aerial Measurements Department (WAMD), Andrews Air Force Base, Maryland; and, (8) Woburn Cathode Ray Tube Operations (WCO), Woburn, Massachusetts. Each of these facilities has an individual Operational Area Monitoring Plan, but they have been consolidated herein to reduce redundancy

  2. Načrtovanje in optimizacija brezžičnega merilnega sistema z Wi-Fi modulom

    OpenAIRE

    RAŽMAN, ROK

    2015-01-01

    Namen tega dela je opisati načrtovanje in optimizacijo delovanja brezžičnega merilnega sistema, ki zajema mikrokrmnilnik, Wi-Fi modul in napajalno vezje, in je priključen na ciljni senzor. Umeščen bo v zelo omejen prostor in to predstavlja precejšno težavo z vidika načrtovanja. Vir napajanja je omrežna izmenična napetost, kar pomeni, da mora sistem vključevati majhen, a dovolj zmogljiv AC-DC pretvornik. Največji porabnik toka v sistemu je Wi-Fi modul. Vse omejitve morajo biti upoštevane in vs...

  3. Deepwater Gulf of Mexico more profitable than previously thought

    International Nuclear Information System (INIS)

    Craig, M.J.K.; Hyde, S.T.

    1997-01-01

    Economic evaluations and recent experience show that the deepwater Gulf of Mexico (GOM) is much more profitable than previously thought. Four factors contributing to the changed viewpoint are: First, deepwater reservoirs have proved to have excellent productive capacity, distribution, and continuity when compared to correlative-age shelf deltaic sands. Second, improved technologies and lower perceived risks have lowered the cost of floating production systems (FPSs). Third, projects now get on-line quicker. Fourth, a collection of other important factors are: Reduced geologic risk and associated high success rates for deepwater GOM wells due primarily to improved seismic imaging and processing tools (3D, AVO, etc.); absence of any political risk in the deepwater GOM (common overseas, and very significant in some international areas); and positive impact of deepwater federal royalty relief. This article uses hypothetical reserve distributions and price forecasts to illustrate indicative economics of deepwater prospects. Economics of Shell Oil Co.'s three deepwater projects are also discussed

  4. A Rock Physics Feasibility Study of the Geothermal Gassum Reservoir, Copenhagen Area, Denmark

    DEFF Research Database (Denmark)

    Bredesen, Kenneth; Dalgaard, Esben Borch; Mathiesen, Anders

    The subsurface of Denmark stores significant amounts of renewable geothermal energy which may contribute to domestic heating for centuries. However, establishing a successful geothermal plant with robust production capacity require reservoirs with sufficient high porosity and permeability. Modern...... quantitative seismic interpretation is a good approach to de-risk prospects and gain reservoir insight, but is so far not widely used for geothermal applications. In this study we perform a rock physics feasibility study as a pre-step towards quantitative seismic interpretation of geothermal reservoirs......, primarily in areas around Copenhagen. The results argue that it may be possible to use AVO and seismic inversion data to distinguish geothermal sandstone reservoirs from surrounding shales and to estimate porosity and permeability. Moreover, this study may represent new possibilities for future rock physics...

  5. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    Energy Technology Data Exchange (ETDEWEB)

    Michael G. Waddell; William J. Domoracki; Jerome Eyer

    2003-01-01

    The Earth Sciences and Resources Institute, University of South Carolina is conducting a proof of concept study to determine the location and distribution of subsurface DNAPL carbon tetrachloride (CCl{sub 4}) contamination at the 216-Z-9 crib, 200 West area, DOE Hanford Site, Washington by use of two-dimensional high-resolution seismic reflection surveys and borehole geophysical data. The study makes use of recent advances in seismic reflection amplitude versus offset (AVO) technology to directly detect the presence of subsurface DNAPL. The techniques proposed are noninvasive means of site characterization and direct free-phase DNAPL detection. This final report covers the results of Tasks 1, 2, and 3. Task (1) contains site evaluation and seismic modeling studies. The site evaluation consists of identifying and collecting preexisting geological and geophysical information regarding subsurface structure and the presence and quantity of DNAPL. The seismic modeling studies were undertaken to determine the likelihood that an AVO response exists and its probable manifestation. Task (2) is the design and acquisition of 2-D seismic reflection data to image areas of probable high concentration of DNAPL. Task (3) is the processing and interpretation of the 2-D data. During the commission of these tasks four seismic reflection profiles were collected. Subsurface velocity information was obtained by vertical seismic profile surveys in three wells. The interpretation of these data is in two parts. Part one is the construction and interpretation of structural contour maps of the contact between the Hanford Fine unit and the underlying Plio/Pleistocene unit and of the contact between the Plio/Pleistocene unit and the underlying caliche layer. These two contacts were determined to be the most likely surfaces to contain the highest concentration CCl{sub 4}. Part two of the interpretation uses the results of the AVO modeling to locate any seismic amplitude anomalies that might be

  6. Recovery of seismic attributes by using the amplitude zero offset migration; Recuperacao de atributos sismicos utilizando a migracao para afastamento nulo em verdadeira amplitude

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, Angela Cristina Romero

    1999-07-01

    In the present work a method was developed to extract reflections coefficients after applying amplitude zero offset migration (TA MZO) on synthetic seismic data composed of several common offset sections. Sorting to the common mid point domain (CMP) provides the conventional amplitude versus offset curve directly. A second MZO application with different weights provides an estimation of incident angles, transforming AVO in AVA. Four models were developed with this objective, which basic difference is the structural complexity. One of these models is based on Brazilian turbidity reservoir of Neo-Albian age and proves the wide applicability of this methodology on reservoir characterization. Final, AVA results were compared with the theoretical AVA, quantifying the relative errors between them.

  7. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    International Nuclear Information System (INIS)

    Waddell, Michael G.; Domoracki, William J.; Eyer, Jerome

    2003-01-01

    The Earth Sciences and Resources Institute, University of South Carolina is conducting a proof of concept study to determine the location and distribution of subsurface DNAPL carbon tetrachloride (CCl 4 ) contamination at the 216-Z-9 crib, 200 West area, DOE Hanford Site, Washington by use of two-dimensional high-resolution seismic reflection surveys and borehole geophysical data. The study makes use of recent advances in seismic reflection amplitude versus offset (AVO) technology to directly detect the presence of subsurface DNAPL. The techniques proposed are noninvasive means of site characterization and direct free-phase DNAPL detection. This final report covers the results of Tasks 1, 2, and 3. Task (1) contains site evaluation and seismic modeling studies. The site evaluation consists of identifying and collecting preexisting geological and geophysical information regarding subsurface structure and the presence and quantity of DNAPL. The seismic modeling studies were undertaken to determine the likelihood that an AVO response exists and its probable manifestation. Task (2) is the design and acquisition of 2-D seismic reflection data to image areas of probable high concentration of DNAPL. Task (3) is the processing and interpretation of the 2-D data. During the commission of these tasks four seismic reflection profiles were collected. Subsurface velocity information was obtained by vertical seismic profile surveys in three wells. The interpretation of these data is in two parts. Part one is the construction and interpretation of structural contour maps of the contact between the Hanford Fine unit and the underlying Plio/Pleistocene unit and of the contact between the Plio/Pleistocene unit and the underlying caliche layer. These two contacts were determined to be the most likely surfaces to contain the highest concentration CCl 4 . Part two of the interpretation uses the results of the AVO modeling to locate any seismic amplitude anomalies that might be

  8. Full Waveform Inversion for Reservoir Characterization - A Synthetic Study

    KAUST Repository

    Zabihi Naeini, E.

    2017-05-26

    Most current reservoir-characterization workflows are based on classic amplitude-variation-with-offset (AVO) inversion techniques. Although these methods have generally served us well over the years, here we examine full-waveform inversion (FWI) as an alternative tool for higher-resolution reservoir characterization. An important step in developing reservoir-oriented FWI is the implementation of facies-based rock physics constraints adapted from the classic methods. We show that such constraints can be incorporated into FWI by adding appropriately designed regularization terms to the objective function. The advantages of the proposed algorithm are demonstrated on both isotropic and VTI (transversely isotropic with a vertical symmetry axis) models with pronounced lateral and vertical heterogeneity. The inversion results are explained using the theoretical radiation patterns produced by perturbations in the medium parameters.

  9. Common-image gathers in the offset domain from reverse-time migration

    KAUST Repository

    Zhan, Ge

    2014-04-01

    Kirchhoff migration is flexible to output common-image gathers (CIGs) in the offset domain by imaging data with different offsets separately. These CIGs supply important information for velocity model updates and amplitude-variation-with-offset (AVO) analysis. Reverse-time migration (RTM) offers more insights into complex geology than Kirchhoff migration by accurately describing wave propagation using the two-way wave equation. But, it has difficulty to produce offset domain CIGs like Kirchhoff migration. In this paper, we develop a method for obtaining offset domain CIGs from RTM. The method first computes the RTM operator of an offset gather, followed by a dot product of the operator and the offset data to form a common-offset RTM image. The offset domain CIGs are then achieved after separately migrating data with different offsets. We generate offset domain CIGs on both the Marmousi synthetic data and 2D Gulf of Mexico real data using this approach. © 2014.

  10. Rock-physics modelling of the North Sea greensand

    DEFF Research Database (Denmark)

    Hossain, Zakir

    cemented, whereas Ty Formation is characterized by microcrystalline quartz cement. A series of laboratory experiments including core analysis, capillary pressure measurements, NMR T2 measurements, acoustic velocity measurements, electrical properties measurements and CO2 injection experiments were done...... cementation and berthierine cementation. Initially greensand is a mixture of mainly quartz and glauconite; when weakly cemented, it has relatively low elastic modulus and can be modeled by a Hertz-Mindlin contact model of two types of grains. Silica-cemented greensand has a relatively high elastic modulus...... and can be modeled by an intermediate-stiff-sand or a stiff-sand model. Berthierine cement has a different growth patterns in different part of the greensand, resulting in a soft-sand model and an intermediate-stiff-sand model. The second rock-physical model predicts Vp-Vs relations and AVO of a greensand...

  11. PBO Operations in Alaska and Cascadia, Combining Regions and Collaborating with our Regional Partners

    Science.gov (United States)

    Austin, K. E.; Boyce, E. S.; Dausz, K.; Feaux, K.; Mattioli, G. S.; Pyatt, C.; Willoughby, H.; Woolace, A. C.

    2015-12-01

    During the last year, the Alaska and the Cascadia regions of the EarthScope Plate Boundary Observatory (PBO) network were combined into a single management unit. While both remain distinct regions with their own challenges and engineering staff, every effort has been made to operate as a single team to improve efficiency and provide the highest possible data quality and uptime. Over the last several years a concerted effort has been made to work collaboratively with other institutions and stakeholders to defray ongoing costs by sharing staff and resources. UNAVCO currently operates four integrated GPS/seismic stations in collaboration with the Alaska Earthquake Center, eight with the Alaska Volcano Observatory, and three with the EarthScope TA. By the end of 2015, PBO and TA plan to install another 3 integrated and/or co-located geodetic and seismic systems. While most of these are designed around existing PBO stations, the 2014 installation at Middleton Island is a new station for both groups, providing PBO with an opportunity to expand geodetic data in Alaska. There were two major joint maintenance efforts in 2015:, the largest was a 5 day mission among PBO, AVO, and TA, which shared boat, helicopter, and staff on and around Augustine Volcano; the second, was a 10 day helicopter mission shared between AVO and PBO on Unimak Island. PBO Pacific Northwest is working closely with University of Washington to co-locate at least 9 Earthquake Early Warning Systems, which include the addition of strong motion sensors and high speed RT telemetry at PBO sites. The project is managed by University of Washington but UNAVCO is providing land contact information and infrastructure support. Summer 2015 upgrades include a complete overhaul of aging radio technology at two major networks and several small radio networks in Cascadia. The upgrades will increase reliability and enhance the speed of existing telemetry infrastructure and will continue through summer 2018.

  12. Correlations among three measures of puberty in mice and relationships with estradiol concentration and ovulation.

    Science.gov (United States)

    Safranski, T J; Lamberson, W R; Keisler, D H

    1993-03-01

    Correlations among ages and weights at vaginal opening (AVO, WVO), positive vaginal smear (AVE, WVE), and copulatory plug (AVP, WVP) were determined using 623 mice. Two additional experiments were conducted to determine association of each with serum concentrations of estradiol and incidence of ovulation. Female mice were weaned at 21 days and 24 days of age were assigned randomly to mate with males. Mice were checked daily to determine AVO, AVE, and AVP. Mice were weighted weekly and WVO, WVE, and WVP were obtained by interpolation. Genetic correlations among ages and weights were small and mainly negative. Phenotypic correlations were small to moderate and mainly positive. Genetic correlations among the three measures of age and among the three measures of weight were moderate to high and positive; respective phenotypic correlations were somewhat smaller. In experiment 2, mice were checked daily for the three reproductive measures and bled at vaginal opening (n = 23), positive smear (n = 18), or copulatory plug (n = 19). Serum was assayed for estradiol via radioimmunoassay. No differences were found among the three indicators (p = 0.34). In experiment 3, mice were randomly assigned to be killed after detection of vaginal opening, positive smear, or copulatory plug. Oviducts were removed and flushed with saline to determine presence of ova. A greater (p < 0.05) proportion of mice had ovulated when killed after detection of copulatory plug (20/22) than after positive smear (4/27), and the proportion was greater after positive smear than after vaginal opening (0/14).(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Satellite monitoring of remote volcanoes improves study efforts in Alaska

    Science.gov (United States)

    Dean, K.; Servilla, M.; Roach, A.; Foster, B.; Engle, K.

    Satellite monitoring of remote volcanoes is greatly benefitting the Alaska Volcano Observatory (AVO), and last year's eruption of the Okmok Volcano in the Aleutian Islands is a good case in point. The facility was able to issue and refine warnings of the eruption and related activity quickly, something that could not have been done using conventional seismic surveillance techniques, since seismometers have not been installed at these locations.AVO monitors about 100 active volcanoes in the North Pacific (NOPAC) region, but only a handful are observed by costly and logistically complex conventional means. The region is remote and vast, about 5000 × 2500 km, extending from Alaska west to the Kamchatka Peninsula in Russia (Figure 1). Warnings are transmitted to local communities and airlines that might be endangered by eruptions. More than 70,000 passenger and cargo flights fly over the region annually, and airborne volcanic ash is a threat to them. Many remote eruptions have been detected shortly after the initial magmatic activity using satellite data, and eruption clouds have been tracked across air traffic routes. Within minutes after eruptions are detected, information is relayed to government agencies, private companies, and the general public using telephone, fax, and e-mail. Monitoring of volcanoes using satellite image data involves direct reception, real-time monitoring, and data analysis. Two satellite data receiving stations, located at the Geophysical Institute, University of Alaska Fairbanks (UAF), are capable of receiving data from the advanced very high resolution radiometer (AVHRR) on National Oceanic and Atmospheric Administration (NOAA) polar orbiting satellites and from synthetic aperture radar (SAR) equipped satellites.

  14. Sex differences in the oxygen delivery, extraction, and uptake during moderate-walking exercise transition.

    Science.gov (United States)

    Beltrame, Thomas; Villar, Rodrigo; Hughson, Richard L

    2017-09-01

    Previous studies in children and older adults demonstrated faster oxygen uptake (V̇O 2 ) kinetics in males compared with females, but young healthy adults have not been studied. We hypothesized that young men would have faster aerobic system dynamics in response to the onset of exercise than women. Interactions between oxygen supply and utilization were characterized by the dynamics of V̇O 2 , deoxyhemoglobin (HHb), tissue saturation index (TSI), cardiac output (Q̇), and calculated arteriovenous O 2 difference (a-vO 2 diff ) in women and men. Eighteen healthy active young women and men (9 of each sex) with similar aerobic fitness levels volunteered for this study. Participants performed an incremental cardiopulmonary treadmill exercise test and 3 moderate-intensity treadmill exercise tests (at 80% V̇O 2 of gas exchange threshold). Data related to the moderate exercise were submitted to exponential data modelling to obtain parameters related to the aerobic system dynamics. The time constants of V̇O 2 , a-vO 2 diff , HHb, and TSI (30 ± 6, 29 ± 1, 16 ± 1, and 15 ± 2 s, respectively) in women were statistically (p < 0.05) faster than the time constants in men (42 ± 10, 49 ± 21, 19 ± 3, and 20 ± 4 s, respectively). Although Q̇ dynamics were not statistically different (p = 0.06) between groups, there was a trend to slower Q̇ dynamics in men corresponding with the slower V̇O 2 kinetics. These results indicated that the peripheral and pulmonary oxygen extraction dynamics were remarkably faster in women. Thus, contrary to the hypothesis, V̇O 2 dynamics measured at the mouth at the onset of submaximal treadmill walking were faster in women compared with men.

  15. Integrating SAR and derived products into operational volcano monitoring and decision support systems

    Science.gov (United States)

    Meyer, F. J.; McAlpin, D. B.; Gong, W.; Ajadi, O.; Arko, S.; Webley, P. W.; Dehn, J.

    2015-02-01

    Remote sensing plays a critical role in operational volcano monitoring due to the often remote locations of volcanic systems and the large spatial extent of potential eruption pre-cursor signals. Despite the all-weather capabilities of radar remote sensing and its high performance in monitoring of change, the contribution of radar data to operational monitoring activities has been limited in the past. This is largely due to: (1) the high costs associated with radar data; (2) traditionally slow data processing and delivery procedures; and (3) the limited temporal sampling provided by spaceborne radars. With this paper, we present new data processing and data integration techniques that mitigate some of these limitations and allow for a meaningful integration of radar data into operational volcano monitoring decision support systems. Specifically, we present fast data access procedures as well as new approaches to multi-track processing that improve near real-time data access and temporal sampling of volcanic systems with SAR data. We introduce phase-based (coherent) and amplitude-based (incoherent) change detection procedures that are able to extract dense time series of hazard information from these data. For a demonstration, we present an integration of our processing system with an operational volcano monitoring system that was developed for use by the Alaska Volcano Observatory (AVO). Through an application to a historic eruption, we show that the integration of SAR into systems such as AVO can significantly improve the ability of operational systems to detect eruptive precursors. Therefore, the developed technology is expected to improve operational hazard detection, alerting, and management capabilities.

  16. Surface layer determination for the Si spheres of the Avogadro project

    Science.gov (United States)

    Busch, I.; Azuma, Y.; Bettin, H.; Cibik, L.; Fuchs, P.; Fujii, K.; Krumrey, M.; Kuetgens, U.; Kuramoto, N.; Mizushima, S.

    2011-04-01

    For the accurate determination of the Avogadro constant, two 28Si spheres were produced, whose macroscopic density, in addition to other values, must be determined. To make a contribution to the new definition of the kilogram, a relative standard uncertainty of less than 2 × 10-8 has to be achieved. Each silicon surface is covered by a surface layer (SL). Consequently, correction parameters for the SL are determined to be applied to the mass and volume determination of the enriched spheres. With the use of a large set of surface analysing techniques, the structure of the SL is investigated. An unexpected metallic contamination existing on the sphere surface enlarges the uncertainty contribution of the correction parameters above the originally targeted value of 1 × 10-8. In the framework of this investigation this new obstacle is resolved in two ways. A new combination of analytical methods is applied to measure the SL mass mSL and the thickness dSL, including this new contamination, with an uncertainty of u(mSL) = 14.5 µg and 14.4 µg, respectively, and u(dSL) = 0.33 nm and 0.32 nm for the 28Si spheres AVO28-S5 and AVO28-S8, respectively. In the second part of the work, the chemical composition of these metallic contaminations is found to be Cu, Ni and Zn silicide compounds. For the removal of this contamination, a special procedure is developed, tested and applied to the spheres to produce the originally expected surface structure on the spheres. After the application of this new procedure the use of x-ray reflectometry directly at the spheres will be possible. It is expected to reduce the uncertainty contribution due to the SL down to 1 × 10-8.

  17. Lysosomes and unfolded protein response, determinants of differential resistance of melanoma cells to vinca alkaloids.

    Science.gov (United States)

    Vincent, Laure-Anais; Attaoua, Chaker; Bellis, Michel; Rozkydalova, Lucie; Hadj-Kaddour, Kamel; Vian, Laurence; Cuq, Pierre

    2015-04-01

    On account of its strong ability to become chemoresistant after a primary response to drugs, malignant melanoma (MM) remains a therapeutic challenge. This study focuses on acquired resistance to vinca alkaloids (VAs) using VA-resistant MM cell lines (CAL1R-VCR, CAL1R-VDS, and CAL1R-VRB), established by long-term continuous exposure of parental CAL1-wt cells to vincristine (VCR), vindesine (VDS), or vinorelbine (VRB), respectively. Transcriptomic profiling using rma and rdam methods led to distinguish two cell groups: CAL1R-VCR and CAL1R-VDS, CAL1R-VRB, and CAL1-wt. mgsa of the specifically altered genes in the first group evidenced the GO terms 'lysosomal lumen' and 'vacuolar lumen' linked to underexpressed genes, and 'endoplasmic reticulum (ER) stress response' associated with overexpressed genes. A specific reduction of lysosomal enzymes, independent of acidic vacuole organelle (AVO) turnover, was observed (LTG probe) in CAL1R-VCR and CAL1R-VDS cells. It was associated with the specific lowering of cathepsin B and L, known to be involved in the lysosomal pathway of apoptosis. Confirming gene profiling, the same groups (CAL1R-VCR and CAL1R-VDS, CAL1-wt and CAL1R-VRB) could be distinguished regarding the VA-mediated changes on mean size areas and on acidic compartment volumes. These two parameters were reduced in CAL1R-VCR and CAL1R-VDS cells, suggesting a smaller AVO accumulation and thus a reduced sensitivity to lysosomal membrane permeabilization-mediated apoptosis. In addition, 'ER stress response' inhibition by tauroursodeoxycholic acid induced a higher VA sensitization of the first cell group. In conclusion, lysosomes and unfolded protein response could be key determinants of the differential resistance of MM to VAs. © 2015 Société Française de Pharmacologie et de Thérapeutique.

  18. A volcanic activity alert-level system for aviation: review of its development and application in Alaska

    Science.gov (United States)

    Guffanti, Marianne; Miller, Thomas P.

    2013-01-01

    An alert-level system for communicating volcano hazard information to the aviation industry was devised by the Alaska Volcano Observatory (AVO) during the 1989–1990 eruption of Redoubt Volcano. The system uses a simple, color-coded ranking that focuses on volcanic ash emissions: Green—normal background; Yellow—signs of unrest; Orange—precursory unrest or minor ash eruption; Red—major ash eruption imminent or underway. The color code has been successfully applied on a regional scale in Alaska for a sustained period. During 2002–2011, elevated color codes were assigned by AVO to 13 volcanoes, eight of which erupted; for that decade, one or more Alaskan volcanoes were at Yellow on 67 % of days and at Orange or Red on 12 % of days. As evidence of its utility, the color code system is integrated into procedures of agencies responsible for air-traffic management and aviation meteorology in Alaska. Furthermore, it is endorsed as a key part of globally coordinated protocols established by the International Civil Aviation Organization to provide warnings of ash hazards to aviation worldwide. The color code and accompanying structured message (called a Volcano Observatory Notice for Aviation) comprise an effective early-warning message system according to the United Nations International Strategy for Disaster Reduction. The aviation color code system currently is used in the United States, Russia, New Zealand, Iceland, and partially in the Philippines, Papua New Guinea, and Indonesia. Although there are some barriers to implementation, with continued education and outreach to Volcano Observatories worldwide, greater use of the aviation color code system is achievable.

  19. Ultra Deep Wave Equation Imaging and Illumination

    Energy Technology Data Exchange (ETDEWEB)

    Alexander M. Popovici; Sergey Fomel; Paul Sava; Sean Crawley; Yining Li; Cristian Lupascu

    2006-09-30

    In this project we developed and tested a novel technology, designed to enhance seismic resolution and imaging of ultra-deep complex geologic structures by using state-of-the-art wave-equation depth migration and wave-equation velocity model building technology for deeper data penetration and recovery, steeper dip and ultra-deep structure imaging, accurate velocity estimation for imaging and pore pressure prediction and accurate illumination and amplitude processing for extending the AVO prediction window. Ultra-deep wave-equation imaging provides greater resolution and accuracy under complex geologic structures where energy multipathing occurs, than what can be accomplished today with standard imaging technology. The objective of the research effort was to examine the feasibility of imaging ultra-deep structures onshore and offshore, by using (1) wave-equation migration, (2) angle-gathers velocity model building, and (3) wave-equation illumination and amplitude compensation. The effort consisted of answering critical technical questions that determine the feasibility of the proposed methodology, testing the theory on synthetic data, and finally applying the technology for imaging ultra-deep real data. Some of the questions answered by this research addressed: (1) the handling of true amplitudes in the downward continuation and imaging algorithm and the preservation of the amplitude with offset or amplitude with angle information required for AVO studies, (2) the effect of several imaging conditions on amplitudes, (3) non-elastic attenuation and approaches for recovering the amplitude and frequency, (4) the effect of aperture and illumination on imaging steep dips and on discriminating the velocities in the ultra-deep structures. All these effects were incorporated in the final imaging step of a real data set acquired specifically to address ultra-deep imaging issues, with large offsets (12,500 m) and long recording time (20 s).

  20. Ultra low-dose chest CT using filtered back projection: Comparison of 80-, 100- and 120 kVp protocols in a prospective randomized study

    Energy Technology Data Exchange (ETDEWEB)

    Khawaja, Ranish Deedar Ali, E-mail: rkhawaja@mgh.harvard.edu [Division of Thoracic Radiology, MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston (United States); Singh, Sarabjeet [Division of Thoracic Radiology, MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston (United States); Madan, Rachna [Division of Thoracic Radiology, Brigham and Women' s Hospital and Harvard Medical School, Boston (United States); Sharma, Amita; Padole, Atul; Pourjabbar, Sarvenaz; Digumarthy, Subba; Shepard, Jo-Anne; Kalra, Mannudeep K. [Division of Thoracic Radiology, MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston (United States)

    2014-10-15

    Highlights: • Filtered back projection technique enables acceptable image quality for chest CT examinations at 0.9 mGy (estimated effective dose of 0.5 mSv) for selected sizes of patients. • Lesion detection (such as solid non-calcified lung nodules) in lung parenchyma is optimal at 0.9 mGy, with limited visualization of thyroid nodules in FBP images. • Further dose reduction down to 0.4 mGy is possible for most patients undergoing follow-up chest CT for evaluation of larger lung nodules and GGOs. • Our results may help set the reference ALARA dose for chest CT examinations reconstructed with filtered back projection technique using the minimum possible radiation dose with acceptable image quality and lesion detection. - Abstract: Purpose: To assess lesion detection and diagnostic image quality of filtered back projection (FBP) reconstruction technique in ultra low-dose chest CT examinations. Methods and materials: In this IRB-approved ongoing prospective clinical study, 116 CT-image-series at four different radiation-doses were performed for 29 patients (age, 57–87 years; F:M – 15:12; BMI 16–32 kg/m{sup 2}). All patients provided written-informed-consent for the acquisitions of additional ultra low-dose (ULD) series on a 256-slice MDCT (iCT, Philips Healthcare). In-addition to their clinical standard-dose chest CT (SD, 120 kV mean CTDI{sub vol}, 6 ± 1 mGy), ULD-CT was subsequently performed at three-dose-levels (0.9 mGy [120 kV]; 0.5 mGy [100 kV] and 0.2 mGy [80 kV]). Images were reconstructed with FBP (2.5 mm * 1.25 mm) resulting into four-stacks: SD-FBP (reference-standard), FBP{sub 0.9}, FBP{sub 0.5}, and FBP{sub 0.2}. Four thoracic-radiologists from two-teaching-hospitals independently-evaluated data for lesion-detection and visibility-of-small-structures. Friedman's-non-parametric-test with post hoc Dunn's-test was used for data-analysis. Results: Interobserver-agreement was substantial between radiologists (k = 0.6–0.8). With

  1. Fractura por fatiga de un tallo de revisión femoral modular cónico estriado de fijación distal.

    Directory of Open Access Journals (Sweden)

    Martin Buttaro

    2013-03-01

    Full Text Available 1. Engelbrecht E, Heinert K. Klassifikation und Behandlungsrichtlinien von Knochensubsanzverlusten bei Revisionsoperationen am Huftgelenk mittelfrsige Ergebnisse. Primare und Revisionsalloarthroplastik Hrsg-Endo-Klinik, Hamburg: Springer-Verlag, Berlin; 1987:189. 2. Merle d’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 1954;36:451. 3. Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mat Res 1983;17:829. 4. Carlsson AS, Gentz CF, Stenport J. Fracture of the femoral prosthesis in total hip replacement according to Charnley. Acta Orthop Scand 1977;48:650-5. 5. Chao EYS, Coventry MB. Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases. J Bone Joint Surg Am 1981;63:1078-94. 6. Charnley J. Fracture of femoral prostheses in total hip replacement. A clinical study. Clin Orthop 1975;111:105. 7. Buttaro M, Mayor M, Van Citters D, Piccaluga F. Fracture of a proximally modular, distally fluted uncemented implant with diaphyseal fixation. J Arthroplasty 2007;22(5:780-3. 8. Bohm P, Bischel O. Femoral revision with the Wagner SL revision stem: evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years. J Bone Joint Surg Am 2001;83(7:1023. 9. Woolson ST, Milbauer JP, Bobyn JD, Yue S, Maloney WJ. Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases. J Bone Joint Surg Am 1997;79(12:1842.

  2. Orthopaedic surgeries - assessment of ionising radiations exposure in health care workers

    International Nuclear Information System (INIS)

    Leite, E.S.; Uva, A.S.

    2006-01-01

    Full text of publication follows: 1. Objectives: The health care workers are exposed to ionizing radiations during their activities. In the operating rooms, the ionizing radiations are used in orthopaedic surgery and the dose depends on some factors, like the characteristics of the equipment. This study aims to: Estimate the occupational dose of ionizing radiations exposure of the orthopaedic doctors and nurses during the orthopaedic surgeries, in a Portuguese operating room; Sensitize the health care workers to use the individual dosimeter and to adopt radiation preventive measures. 2. Population and methods The study was conducted on nine Orthopaedic doctors and two nurses of an operating room of a hospital in Lisbon neighborhoods. We made a risk evaluating concerning: the radiations dose in different points, corresponding to gonads, hands and crystalline lens levels of all the professionals, during the surgeries; the average period of radiation in the orthopaedic surgeries; the number of annual orthopaedic surgeries, looking for that in the surgeries registers, to estimate the annual ionizing radiations dose of each orthopaedic doctor and nurse. 3. Results The annual doses estimated at different levels for orthopaedic doctors were the following: gonads: between 20,63 and 68,75 mGy; hands: 4,95 16,50 mGy; crystalline lens: 8,25 27,50 mGy). For the orthopaedic nurses: gonads: 130,63 151,25 mGy; hands: 31,35 36,30 mGy; crystalline lens 52,25 60,25 mGy. 4. Conclusions Although the location and positions of health care workers are not the same during the different surgeries and the equipment has an automatic control of the X ray emission, the annual ionizing radiations dose exposure for health care workers is an important one. The risk rating justifies the use of individual dosimeters for better individual dose assessment as part of an ionizing radiations prevention program. As a matter of fact preventive measures begin with a good quantitative risk assessment of

  3. Assessment of mean glandular dose for patients in mammography in some Hospitals in Khartoum state

    International Nuclear Information System (INIS)

    Abu Elmola, Alaa Mahdi

    2016-12-01

    A mammography examination facilitates the early detection of breast cancer. However, the potential risk of radiation- induced carcinogenesis is also increased with such a procedure. Thus assessment of the breast dose is important. The objective of this study was to determine the mean glandular dose (MGD) resulting from cranio caudal(CC) and mediolateral oblique (MLO) views in one breast and the total dose per woman in Sudan, and to identify the factors affecting it. Measurements were performed to estimate mean glandular doses for 60 patients who underwent mammography examination in two clinics in Khartoum, Sudan.Doses were studied in RCH and NDC, centers which were using computed radiography(CR)devices. The piranha system was used for determining the MGD in this work. The characteristics of the radiographic equipment and the exposure data of each patient were recorded using designed format. The MGD was calculated from the measured incident Air kerma using appropriate conversion coefficients. The range of CBT was (1-7)cm for two projections. The respective averages for the CC and MLO projections were (4.55±1.38)mGy and (4.15±1.33) mGy, respectively. The average MGD per image was (4.3±1.35)mGy. The MGD per women was (8.6±1.35)mGy. The mean±SD MGD per image in the present study was lower than most of similar reports. The average MGD values recorded in this study were above the limiting value of the Institute of Physical Sciences in Medicine(2.0 mGy) and American College of Radiology (3.0 mGy recommendation. This suggests that mammography x-ray generators in this case are not capable of achieving acceptable dose levels for patients safety. Therefore, with consideration of all other factors, quality control program tests must be carried out periodically and frequently of the mammography equipment.(Author)

  4. WE-D-18A-04: How Iterative Reconstruction Algorithms Affect the MTFs of Variable-Contrast Targets in CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Dodge, C.T.; Rong, J. [MD Anderson Cancer Center, Houston, TX (United States); Dodge, C.W. [Methodist Hospital, Houston, TX (United States)

    2014-06-15

    Purpose: To determine how filtered back-projection (FBP), adaptive statistical (ASiR), and model based (MBIR) iterative reconstruction algorithms affect the measured modulation transfer functions (MTFs) of variable-contrast targets over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP401 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 24 mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 2.5mm thickness, 0.984 pitch. The images were reconstructed using GE's Standard kernel with FBP; 20%, 40% and 70% ASiR; and MBIR. A task-based MTF (MTFtask) was computed for six cylindrical targets: 2 low-contrast (Polystyrene, LDPE), 2 medium-contrast (Delrin, PMP), and 2 high-contrast (Teflon, air). MTFtask was used to compare the performance of reconstruction algorithms with decreasing CTDIvol from 24mGy, which is currently used in the clinic. Results: For the air target and 75% dose savings (6 mGy), MBIR MTFtask at 5 lp/cm measured 0.24, compared to 0.20 for 70% ASiR and 0.11 for FBP. Overall, for both high-contrast targets, MBIR MTFtask improved with increasing CTDIvol and consistently outperformed ASiR and FBP near the system's Nyquist frequency. Conversely, for Polystyrene at 6 mGy, MBIR (0.10) and 70% ASiR (0.07) MTFtask was lower than for FBP (0.18). For medium and low-contrast targets, FBP remains the best overall algorithm for improved resolution at low CTDIvol (1–6 mGy) levels, whereas MBIR is comparable at higher dose levels (12–24 mGy). Conclusion: MBIR improved the MTF of small, high-contrast targets compared to FBP and ASiR at doses of 50%–12.5% of those currently used in the clinic. However, for imaging low- and mediumcontrast targets, FBP performed the best across all dose levels. For assessing MTF from different reconstruction algorithms, task-based MTF measurements are necessary.

  5. The evaluation of the performance of the automatic exposure control system of some selected mammography facilities in the Greater Accra Region, Ghana

    International Nuclear Information System (INIS)

    Amesimenu, R.

    2013-07-01

    dark films also accounted for film reject signifying the need for continuous training for radiographers and an effective quality control programme. Estimated mean glandular dose (MGD) of values 1.0 mGy, 1.3 mGy, 1.1 mGy and 1.1 mGy at 28 KV for the selected facilities were less than 2 mGy and 3 mGy per the recommendation of International Atomic Energy Agency (IAEA) and American College of Radiology (ACR) respectively. Management of mammography facilities must establish an effective quality management system which must be implemented and continually improved to enhance radiological services delievered to patients as well as improve radiation protection of patients. (au)

  6. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Santangelo, Teresa [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Bambino Gesu Children' s Hospital, Department of Imaging, Rome (Italy); Duhamel, Alain [University of Lille (EA 2694), Department of Biostatistics, CHU Lille, Lille (France); Deschildre, Antoine [CHU Lille - University of Lille, Department of Pediatric Pulmonology, Lille (France)

    2017-02-15

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol{sub 32}) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP{sub 32} was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP{sub 32}, CTDI{sub vol32} and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP{sub 32}, 0.78-1.25 mGy for the CTDI{sub vol32} and 1.6-2.1 mGy for the SSDE. (orig.)

  7. STUDY OF THE SEDIMENTATION TREND IN THE PROSPECTIVE AREA OF PORT OF MARINE CENTER, CIREBON BASED ON REMOTE SENSING DATA

    Directory of Open Access Journals (Sweden)

    Undang Hernawan

    2017-07-01

    Full Text Available A coastal zone is the interface between the land and water that influenced by both of them. Coastal dynamic is influenced by many factors from land and sea, such as sedimentation and current. In order to support marine facility, Marine Geological Institute of Indonesia (MGI plan to build a port. The prospective area is behind MGI office at Cirebon. This study use multi temporal remote sensing data in order to observe trend of coastline change around MGI. Based on the interpretation of the data, there are sedimentation around the MGI water and abrasion due to the presence of Kejawanan’s jetty and Kalijaga River. The result also shows that the current in this region is moving from southeast to northwest. The presence of the Kejawanan’s jetty stymies the movement of sediment. The sediment which is normally moving to the north of the jetty is then trapped on the south side of the structure, so that the sediment precipitates in this region and makes it as the active region of sedimentation and accretion. The presence mangrove conduces to support sedimentation speed and accretion at this region, because of his function as the catchment area. Abrasion occurs in the eastern part of MGI office at the Kalijaga river mouth within the bay. The Kalijaga River mouth is predicted to be the primary source of sedimentation in this area. The coastline change caused by sedimentation will be continuing as long as it is supplied by the sediment. The direction of the sedimentation is parallel to the jetty and it forms ellipsoid, with the sedimentation/accretion region is behind MGI office. The abrasion area is found in Kalijaga River mouth and a small area beside Kalijaga River. In order to build a port, we have to consider this sedimentation process. One of the alternatives to build the port is to make a quay pile model which gives way the current to pass through the other side of the port. Another alternative is to build the port as a pond model but

  8. Image evaluation and exposure dose with the application of tube voltage and adaptive statistical iterative reconstruction of low dose computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Joon [Dept. of Radiology, Konkuk University Medical Center, Seoul (Korea, Republic of); Kim, Ki Jeong [Dept. of Radiology, Wonkwang University Hospital, Iksan (Korea, Republic of); Lee, Hye Nam [Dept. of Radiology, Gimsangyeong Internal Medicine Clinic, Nonsan (Korea, Republic of)

    2017-06-15

    The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were 103.21 mGy‧cm with no-ASIR and 85.94 mGy‧cm with 20%-ASIR, decreased by 17.27mGy‧cm (about 16.7%), and the values with 100 kVp were 63.84 mGy‧cm with no-ASIR and 53.25 mGy‧cm with 20%-ASIR, a decrease by 10.62 mGy‧cm ( about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

  9. TU-D-209-01: Dosimetry of Diagnostic Work Up Mammography

    Energy Technology Data Exchange (ETDEWEB)

    Jallow, N [Emory University, Atlanta, GA (United States); Sechopoulos, I [Radboud University Medical Centre, Nijmegen (Netherlands)

    2016-06-15

    Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulation of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.

  10. A completed audit cycle of the lateral scan projection radiograph in CT pulmonary angiography (CTPA); the impact on scan length and radiation dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2013-01-01

    Aim: To investigate the effect of incorporating a lateral scan projection radiograph (topogram) in addition to the standard frontal topogram on excess scan length in computed tomography pulmonary angiography (CTPA) and to quantify the impact on effective dose. Materials and methods: Fifty consecutive patients referred for exclusion of pulmonary embolism who had undergone a CTPA examination with conventional frontal topogram to plan scan length (protocol A) were compared with 50 consecutive patients who had undergone a CTPA study with frontal and additional lateral topogram for planning (protocol B) in a retrospective audit. Optimal scan length was defined from lung apex to lung base. Mean excess scan length beyond these landmarks was determined. The mean organ doses to the thyroid, liver, and stomach, as well as mean effective dose, were estimated using standard conversion factors. Results: The mean excess scan length was significantly lower in protocol B compared to the protocol A cohort (19.5 ± 17.4 mm [mean ± standard deviation] versus 39.1 ± 20.4 mm, p < 0.0001). The mean excess scan length below the lung bases was significantly lower in the protocol B cohort compared to the protocol A group (7.5 ± 12.7 mm versus 23 ± 16.6 mm, p < 0.0001), as were the mean organ doses to the stomach (4.24 ± 0.81 mGy versus 5.22 ± 1.06 mGy, p < 0.0001) and liver (5.60 ± 0.64 mGy versus 6.38 ± 0.81 mGy, p < 0.0001). A non-significant reduction in over-scanning above the apices in protocol B was observed compared with protocol A (12 ± 8.8 mm versus 16.2 ± 13.6 mm, p = 0.07), which equated to lower mean thyroid organ dose in (3.28 ± 1.76 mGy versus 4.11 ± 3.11 mGy, p = 0.104). Conclusion: The present audit indicates that incorporation of a lateral topogram into the CTPA protocol, together with radiographer education, reduces excess scan length, which significantly reduces the dose to the liver and stomach, and potentially lowers the dose to the thyroid. This simple

  11. Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

    Science.gov (United States)

    Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-07-08

    The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in

  12. External dose reconstruction in tooth enamel of Techa riverside residents

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A.; Volchkova, A.Yu.; Krivoschapov, V.A.; Degteva, M.O. [Urals Research Center for Radiation Medicine, Chelyabinsk (Russian Federation); Timofeev, Y.S.; Zalyapin, V.I. [Southern Urals State University, Chelyabinsk (Russian Federation); Fattibene, P.; Della Monaca, S.; De Coste, V. [Istituto Superiore di Sanita e Istituto Nazionale di Fisica Nucleare, Rome (Italy); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, Neuherberg (Germany); Ivanov, D.V. [M.N. Mikheev Institute of Metal Physics, Ural Division of the Russian Academy of Sciences, Ekaterinburg (Russian Federation); Ural Federal University, Yekaterinburg (Russian Federation); Anspaugh, L.R. [University of Utah, Salt Lake City, UT (United States)

    2016-11-15

    This study summarizes the 20-year efforts for dose reconstruction in tooth enamel of the Techa riverside residents exposed to ionizing radiation as a result of radionuclide releases into the river in 1949-1956. It represents the first combined analysis of all the data available on EPR dosimetry with teeth of permanent residents of the Techa riverside territory. Results of electron paramagnetic resonance (EPR) measurements of 302 teeth donated by 173 individuals living permanently in Techa riverside settlements over the period of 1950-1952 were analyzed. These people were residents of villages located at the free-flowing river stream or at the banks of stagnant reservoirs such as ponds or blind river forks. Cumulative absorbed doses measured using EPR are from several sources of exposure, viz., background radiation, internal exposure due to bone-seeking radionuclides ({sup 89}Sr, {sup 90}Sr/{sup 90}Y), internal exposure due to {sup 137}Cs/{sup 137m}Ba incorporated in soft tissues, and anthropogenic external exposure. The purpose of the present study was to evaluate the contribution of different sources of enamel exposure and to deduce external doses to be used for validation of the Techa River Dosimetry System (TRDS). Since various EPR methods were used, harmonization of these methods was critical. Overall, the mean cumulative background dose was found to be 63 ± 47 mGy; cumulative internal doses due to {sup 89}Sr and {sup 90}Sr/{sup 90}Y were within the range of 10-110 mGy; cumulative internal doses due to {sup 137}Cs/{sup 137m}Ba depend on the distance from the site of releases and varied from 1 mGy up to 90 mGy; mean external doses were maximum for settlements located at the banks of stagnant reservoirs (∝500 mGy); in contrast, external doses for settlements located along the free-flowing river stream did not exceed 160 mGy and decreased downstream with increasing distance from the site of release. External enamel doses calculated using the TRDS code and

  13. Health effect of low dose/low dose rate radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji

    2012-01-01

    The clarified and non-clarified scientific knowledge is discussed to consider the cause of confusion of explanation of the title subject. The low dose is defined roughly lower than 200 mGy and low dose rate, 0.05 mGy/min. The health effect is evaluated from 2 aspects of clinical symptom/radiation hazard protection. In the clinical aspect, the effect is classified in physical (early and late) and genetic ones, and is classified in stochastic (no threshold value, TV) and deterministic (with TV) ones from the radioprotection aspect. Although the absence of TV in the carcinogenic and genetic effects has not been proved, ICRP employs the stochastic standpoint from the safety aspect for radioprotection. The lowest human TV known now is 100 mGy, meaning that human deterministic effect would not be generated below this dose. Genetic deterministic effect can be observable only in animal experiments. These facts suggest that the practical risk of exposure to <100 mGy in human is the carcinogenesis. The relationship between carcinogenic risk in A-bomb survivors and their exposed dose are found fitted to the linear no TV model, but the epidemiologic data, because of restriction of subject number analyzed, do not always mean that the model is applicable even below the dose <100 mGy. This would be one of confusing causes in explanation: no carcinogenic risk at <100 mGy or risk linear to dose even at <100 mGy, neither of which is scientifically conclusive at present. Also mentioned is the scarce risk of cancer in residents living in the high background radiation regions in the world in comparison with that in the A-bomb survivors exposed to the chronic or acute low dose/dose rate. Molecular events are explained for the low-dose radiation-induced DNA damage and its repair, gene mutation and chromosome aberration, hypothesis of carcinogenesis by mutation, and non-targeting effect of radiation (bystander effect and gene instability). Further researches to elucidate the low dose

  14. Comparative proteomic analysis of rice after seed ground simulated radiation and spaceflight explains the radiation effects of space environment

    Science.gov (United States)

    Wang, Wei; Shi, Jinming; Liang, Shujian; Lei, Huang; Shenyi, Zhang; Sun, Yeqing

    In previous work, we compared the proteomic profiles of rice plants growing after seed space-flights with ground controls by two-dimensional difference gel electrophoresis (2-D DIGE) and found that the protein expression profiles were changed after seed space environment exposures. Spaceflight represents a complex environmental condition in which several interacting factors such as cosmic radiation, microgravity and space magnetic fields are involved. Rice seed is in the process of dormant of plant development, showing high resistance against stresses, so the highly ionizing radiation (HZE) in space is considered as main factor causing biological effects to seeds. To further investigate the radiation effects of space environment, we performed on-ground simulated HZE particle radiation and compared between the proteomes of seed irra-diated plants and seed spaceflight (20th recoverable satellite) plants from the same rice variety. Space ionization shows low-dose but high energy particle effects, for searching the particle effects, ground radiations with the same low-dose (2mGy) but different liner energy transfer (LET) values (13.3KeV/µm-C, 30KeV/µm-C, 31KeV/µm-Ne, 62.2KeV/µm-C, 500Kev/µm-Fe) were performed; using 2-D DIGE coupled with clustering and principle component analysis (PCA) for data process and comparison, we found that the holistic protein expression patterns of plants irradiated by LET-62.2KeV/µm carbon particles were most similar to spaceflight. In addition, although space environment presents a low-dose radiation (0.177 mGy/day on the satellite), the equivalent simulated radiation dose effects should still be evaluated: radiations of LET-62.2KeV/µm carbon particles with different cumulative doses (2mGy, 20mGy, 200mGy, 2000mGy) were further carried out and resulted that the 2mGy radiation still shared most similar proteomic profiles with spaceflight, confirming the low-dose effects of space radiation. Therefore, in the protein expression level

  15. Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination.

    Science.gov (United States)

    McKnight, Colin D; Watcharotone, Kuanwong; Ibrahim, Mohannad; Christodoulou, Emmanuel; Baer, Aaron H; Parmar, Hemant A

    2014-08-01

    Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited. The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population. Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDIvol) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality. The average CTDIvol value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDIvol for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDIvol in the ASIR group (P ASIR group as compared to the 3- to 12-year-old non-ASIR group (21.5 mGy vs. 30.0 mGy; P = 0.004) as well as statistically significant reductions in CTDI for the >12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the homogeneity of variance in the ASIR group compared to the non-ASIR group. Radiologist assessment of

  16. Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Colin D.; Watcharotone, Kuanwong; Ibrahim, Mohannad; Christodoulou, Emmanuel; Baer, Aaron H.; Parmar, Hemant A. [University of Michigan, Department of Radiology, Ann Arbor, MI (United States)

    2014-08-15

    Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited. The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population. Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDI{sub vol}) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality. The average CTDI{sub vol} value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDI{sub vol} for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDI{sub vol} in the ASIR group (P < 0.01). There were statistically significant reductions in CTDI for the 3- to 12-year-old ASIR group as compared to the 3- to 12-year-old non-ASIR group (21.5 mGy vs. 30.0 mGy; P = 0.004) as well as statistically significant reductions in CTDI for the >12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the

  17. WE-D-18A-04: How Iterative Reconstruction Algorithms Affect the MTFs of Variable-Contrast Targets in CT Images

    International Nuclear Information System (INIS)

    Dodge, C.T.; Rong, J.; Dodge, C.W.

    2014-01-01

    Purpose: To determine how filtered back-projection (FBP), adaptive statistical (ASiR), and model based (MBIR) iterative reconstruction algorithms affect the measured modulation transfer functions (MTFs) of variable-contrast targets over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP401 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 24 mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 2.5mm thickness, 0.984 pitch. The images were reconstructed using GE's Standard kernel with FBP; 20%, 40% and 70% ASiR; and MBIR. A task-based MTF (MTFtask) was computed for six cylindrical targets: 2 low-contrast (Polystyrene, LDPE), 2 medium-contrast (Delrin, PMP), and 2 high-contrast (Teflon, air). MTFtask was used to compare the performance of reconstruction algorithms with decreasing CTDIvol from 24mGy, which is currently used in the clinic. Results: For the air target and 75% dose savings (6 mGy), MBIR MTFtask at 5 lp/cm measured 0.24, compared to 0.20 for 70% ASiR and 0.11 for FBP. Overall, for both high-contrast targets, MBIR MTFtask improved with increasing CTDIvol and consistently outperformed ASiR and FBP near the system's Nyquist frequency. Conversely, for Polystyrene at 6 mGy, MBIR (0.10) and 70% ASiR (0.07) MTFtask was lower than for FBP (0.18). For medium and low-contrast targets, FBP remains the best overall algorithm for improved resolution at low CTDIvol (1–6 mGy) levels, whereas MBIR is comparable at higher dose levels (12–24 mGy). Conclusion: MBIR improved the MTF of small, high-contrast targets compared to FBP and ASiR at doses of 50%–12.5% of those currently used in the clinic. However, for imaging low- and mediumcontrast targets, FBP performed the best across all dose levels. For assessing MTF from different reconstruction algorithms, task-based MTF measurements are necessary

  18. Image evaluation and exposure dose with the application of tube voltage and adaptive statistical iterative reconstruction of low dose computed tomography

    International Nuclear Information System (INIS)

    Moon, Tae Joon; Kim, Ki Jeong; Lee, Hye Nam

    2017-01-01

    The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were 103.21 mGy‧cm with no-ASIR and 85.94 mGy‧cm with 20%-ASIR, decreased by 17.27mGy‧cm (about 16.7%), and the values with 100 kVp were 63.84 mGy‧cm with no-ASIR and 53.25 mGy‧cm with 20%-ASIR, a decrease by 10.62 mGy‧cm ( about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise

  19. TU-D-209-01: Dosimetry of Diagnostic Work Up Mammography

    International Nuclear Information System (INIS)

    Jallow, N; Sechopoulos, I

    2016-01-01

    Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulation of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.

  20. Optimization of pediatric examinations in a multislice helical CT

    International Nuclear Information System (INIS)

    Ombada, T. H. A.

    2010-12-01

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI v ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI v ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)