WorldWideScience

Sample records for energy radiological control

  1. US Department of Energy radiological control manual

    International Nuclear Information System (INIS)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements

  2. US Department of Energy Radiological Control Manual

    International Nuclear Information System (INIS)

    1992-06-01

    This manual establishes practices for the conduct of radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. (VC)

  3. US Department of Energy radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE`s positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements.

  4. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  5. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  6. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  7. Radiological safety and control

    International Nuclear Information System (INIS)

    Kim, Jang Hee; Kim, Ki Sub

    1995-01-01

    The practical objective of radiological safety control is intended for achievement and maintenance of appropreately safe condition in environmental control for activities involving exposure from the use of radiation. In order to establish these objectives, we should be to prevent deterministic effects and to limit the occurrence stochastic effects to level deemed to be acceptable by the application of general principles of radiation protection and systems of dose limitation based on ICRP recommendations. 34 tabs., 19 figs., 11 refs. (Author) .new

  8. Radiological control implementation guide

    International Nuclear Information System (INIS)

    Hamley, S.A.

    1993-01-01

    A manual is being developed to explain to line managers how radiological controls are designed and implemented. The manual also fills a gap in the Health Physics literature between textbooks and on-the-floor procedures. It may be helpful to new Health Physicists with little practical experience and to those wishing to improve self-assessment, audit, and appraisal processes. Many audits, appraisals, and evaluations have indicated a need for cultural change, increased vigor and example, and more effective oversight by line management. Inadequate work controls are a frequent and recurring problem identified in occurrence reports and accident investigations. Closer study frequently indicates that many line managers are willing to change and want to achieve excellence, but no effective guidance exists that will enable them to understand and implement a modern radiological control program

  9. Radiological safety and control

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Sea Young; Yoo, Y S; Lee, J C; Lee, T Y; Lee, J L; Kim, B W; Lee, B J; Chung, K K; Chung, R I; Kim, J S; Lee, H S; Han, Y D; Lee, J I; Lee, K C; Yoon, J H; Sul, C W; Kim, C K; Yoon, K S; Seo, K W; Yoon, Y C [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    This report describes the annual results of radiological safety and control program of 1995. This program consists of working area monitoring including HANARO, personnel radiation monitoring, education for radiation protection. As a result, the objectives of radiation protection have been achieved satisfactorily through the activities mentioned above. Also, the calibration services were provided to insure accurate radiation measurement in the radiation working places. 21 figs., 39 tabs., 5 refs. (Author) .new.

  10. DOE standard: Radiological control

    Energy Technology Data Exchange (ETDEWEB)

    1999-07-01

    The Department of Energy (DOE) has developed this Standard to assist line managers in meeting their responsibilities for implementing occupational radiological control programs. DOE has established regulatory requirements for occupational radiation protection in Title 10 of the Code of Federal Regulations, Part 835 (10 CFR 835), ``Occupational Radiation Protection``. Failure to comply with these requirements may lead to appropriate enforcement actions as authorized under the Price Anderson Act Amendments (PAAA). While this Standard does not establish requirements, it does restate, paraphrase, or cite many (but not all) of the requirements of 10 CFR 835 and related documents (e.g., occupational safety and health, hazardous materials transportation, and environmental protection standards). Because of the wide range of activities undertaken by DOE and the varying requirements affecting these activities, DOE does not believe that it would be practical or useful to identify and reproduce the entire range of health and safety requirements in this Standard and therefore has not done so. In all cases, DOE cautions the user to review any underlying regulatory and contractual requirements and the primary guidance documents in their original context to ensure that the site program is adequate to ensure continuing compliance with the applicable requirements. To assist its operating entities in achieving and maintaining compliance with the requirements of 10 CFR 835, DOE has established its primary regulatory guidance in the DOE G 441.1 series of Guides. This Standard supplements the DOE G 441.1 series of Guides and serves as a secondary source of guidance for achieving compliance with 10 CFR 835.

  11. DOE standard: Radiological control

    International Nuclear Information System (INIS)

    1999-07-01

    The Department of Energy (DOE) has developed this Standard to assist line managers in meeting their responsibilities for implementing occupational radiological control programs. DOE has established regulatory requirements for occupational radiation protection in Title 10 of the Code of Federal Regulations, Part 835 (10 CFR 835), ''Occupational Radiation Protection''. Failure to comply with these requirements may lead to appropriate enforcement actions as authorized under the Price Anderson Act Amendments (PAAA). While this Standard does not establish requirements, it does restate, paraphrase, or cite many (but not all) of the requirements of 10 CFR 835 and related documents (e.g., occupational safety and health, hazardous materials transportation, and environmental protection standards). Because of the wide range of activities undertaken by DOE and the varying requirements affecting these activities, DOE does not believe that it would be practical or useful to identify and reproduce the entire range of health and safety requirements in this Standard and therefore has not done so. In all cases, DOE cautions the user to review any underlying regulatory and contractual requirements and the primary guidance documents in their original context to ensure that the site program is adequate to ensure continuing compliance with the applicable requirements. To assist its operating entities in achieving and maintaining compliance with the requirements of 10 CFR 835, DOE has established its primary regulatory guidance in the DOE G 441.1 series of Guides. This Standard supplements the DOE G 441.1 series of Guides and serves as a secondary source of guidance for achieving compliance with 10 CFR 835

  12. Radiological controls integrated into design

    Energy Technology Data Exchange (ETDEWEB)

    Kindred, G.W. [Cleveland Electric Illuminating Co., Perry, OH (United States)

    1995-03-01

    Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facility from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.

  13. Proposed quality control protocol of a dual energy bone densitometer from Spanish protocol for quality control of radiology

    International Nuclear Information System (INIS)

    Saez, F.; Benito, M. A.; Collado, P.; Saez, M.

    2011-01-01

    In this paper we propose additional testing to complete the tests by the Spanish Protocol for Quality Control of Diagnostic Radiology, taking into account the particular characteristics of these units, and including these tests in the estimation of patient dose dose assessment area. There is also the possibility to independently verify the quality control tests that are done automatically.

  14. DOE Radiological Control Manual Core Training Program

    International Nuclear Information System (INIS)

    Scott, H.L.; Maisler, J.

    1993-01-01

    Over the past year, the Department of Energy (DOE) Office of Health (EH-40) has taken a leading role in the development of new standardized radiological control training programs for use throughout the DOE complex. The Department promulgated its Radiological Control (RadCon) Manual in June 1992. To ensure consistent application of the criteria presented in the RadCon Manual, standardized radiological control core training courses and training materials have been developed for implementation at all DOE facilities. In producing local training programs, standardized core courses are to be supplemented with site-specific lesson plans, viewgraphs, student handbooks, qualification standards, question banks, and wallet-sized training certificates. Training programs for General Employee Radiological Training, Radiological Worker I and II Training, and Radiological Control Technician Training have been disseminated. Also, training committees under the direction of the Office of Health (EH-40) have been established for the development of additional core training courses, development of examination banks, and the update of the existing core training courses. This paper discusses the current activities and future direction of the DOE radiological control core training program

  15. Radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP.

  16. Radiological control manual. Revision 1

    International Nuclear Information System (INIS)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP

  17. Radiological Control Manual. Revision 0, January 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  18. A radiological control implementation guide

    International Nuclear Information System (INIS)

    Hamley, S.A.

    1993-01-01

    A manual is being developed to explain to line managers how radiological controls are designed and implemented. The manual also fills a gap in the Health Physics literature between textbooks and on-the-floor procedures. It may be helpful to new Health Physicists with little practical experience and to those wishing to improve self-assessment, audit, and appraisal processes. Many audits, appraisals, and evaluations have indicated a need for cultural change, increased vigor and example, and more effective oversight by line management. Inadequate work controls are a frequent and recurring problem identified in occurrence reports and accident investigations. Closer study frequently indicates that many line managers are willing to change and want to achieve excellence, but no effective guidance exists that will enable them to understand and implement a modern radiological control program. The manual is now in draft form and includes information that will be of use to line managers dealing with improving radiological performance and the practical aspects of radiological controls implementation. The manual is expected to be completed by the fall of 1993 and to be used in conjunction with a performance-based self-assessment training program at the Oak Ridge National Laboratory

  19. Radiological control technician: Training program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE Radiological Control Technician Core Training Program qualification and training process, material development requirements, standards and policies, and administration. The manual applies to Radiological Control Technician Training Programs at all DOE contractor sites

  20. Development and maintenance of the Hanford Site Radiological Control Manual

    International Nuclear Information System (INIS)

    Munson, L.H.; Selby, J.M.; Vargo, G.J.; Clark, D.L.

    1993-04-01

    In June 1992 the US Department of Energy (DOE) issued DOE N5480.6, Radiological Control, which set forth DOE's Radiological Control Program and established the framework for its implementation at sites nationwide. Accompanying the Order was the DOE Radiological Control Manual (DOE RCM), which provided the detailed requirements for the program. The Order also mandated Field Office issuance of site-specific radiological control manuals by December 1, 1992. This paper presents the approach taken to develop, review, approve, implement, and subsequently maintain the site-specific manual for the DOE Richland Field Office (RL) at Hanford Site

  1. Radiological controls and worker and public health and safety: An independent safety assessment of Department of Energy nuclear reactor facilities

    International Nuclear Information System (INIS)

    Tew, J.L.; Miles, M.E.; Knuth, D.; Boyd, R.

    1981-02-01

    DOE has formed a Nuclear Facilities Personnel Qualification and Training (NFPQT) Committee to assess the implications of the Report of the President's Commission on the Accident at Three Mile Island that are applicable to DOE's nuclear reactor operations. Thirteen DOE nuclear reactors were reviewed by the Committee. This report was prepared to provide a measure of how the radiological control and environmental practices at the 13 individual DOE reactor facilities measure up to (1) the recommendations contained in the Report of the President's Commission on the Accident at Three Mile Island, (2) the requirements and guidelines contained, and (3) the requirements of the applicable Title and Part of the Code of Federal Regulations

  2. Radiological Control Technician: Phase 2, Core/site practical training

    International Nuclear Information System (INIS)

    1992-10-01

    This volume provides a description of the guidelines, qualification in radiological instrumentation, qualification in radiological protection, and qualification in emergency preparedness for radiological control technicians

  3. Nevada National Security Site Radiological Control Manual

    International Nuclear Information System (INIS)

    2012-01-01

    This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 1 issued in February 2010. Brief Description of Revision: A complete revision to reflect a recent change in name for the NTS; changes in name for some tenant organizations; and to update references to current DOE policies, orders, and guidance documents. Article 237.2 was deleted. Appendix 3B was updated. Article 411.2 was modified. Article 422 was re-written to reflect the wording of DOE O 458.1. Article 431.6.d was modified. The glossary was updated. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada National Security Site (NNSS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. Current activities at NNSS include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of

  4. Nevada National Security Site Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers’ Council

    2012-03-26

    This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 1 issued in February 2010. Brief Description of Revision: A complete revision to reflect a recent change in name for the NTS; changes in name for some tenant organizations; and to update references to current DOE policies, orders, and guidance documents. Article 237.2 was deleted. Appendix 3B was updated. Article 411.2 was modified. Article 422 was re-written to reflect the wording of DOE O 458.1. Article 431.6.d was modified. The glossary was updated. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada National Security Site (NNSS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. Current activities at NNSS include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of

  5. NV/YMP RADIOLOGICAL CONTROL MANUAL

    Energy Technology Data Exchange (ETDEWEB)

    U.S. DEPARTMENT OF ENERGY, NATIONAL NUCLEAR SECURITY ADMINISTRATION NEVADA SITE OFFICE; BECHTEL NEVADA

    2004-11-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual.

  6. NV/YMP RADIOLOGICAL CONTROL MANUAL

    International Nuclear Information System (INIS)

    2004-01-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual

  7. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  8. Key parameters controlling radiology departments

    International Nuclear Information System (INIS)

    Busch, Hans-Peter

    2011-01-01

    For radiology departments and outstanding practises control and optimization of processes demand an efficient management based on key data. Systems of key data deliver indicators for control of medical quality, service quality and economics. For practices effectiveness (productivity), for hospitals effectiveness and efficiency are in the focus of economical optimization strategies. Task of daily key data is continuous monitoring of activities and workflow, task of weekly/monthly key data is control of data quality, process quality and achievement of objectives, task of yearly key data is determination of long term strategies (marketing) and comparison with competitors (benchmarking). Key parameters have to be defined clearly and have to be available directly. For generation, evaluation and control of key parameters suitable forms of organization and processes are necessary. Strategies for the future will be directed more to the total processes of treatment. To think in total processes and to steer and optimize with suitable parameters is the challenge for participants in the healthcare market of the future. (orig.)

  9. Nevada Test Site Radiological Control Manual

    International Nuclear Information System (INIS)

    2009-01-01

    This document supersedes DOE/NV/11718--079, 'NV/YMP Radiological Control Manual,' Revision 5 issued in November 2004. Brief Description of Revision: A complete revision to reflect the recent changes in compliance requirements with 10 CFR 835, and for use as a reference document for Tenant Organization Radiological Protection Programs.

  10. Nevada Test Site Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council - Nevada Test Site

    2009-10-01

    This document supersedes DOE/NV/11718--079, “NV/YMP Radiological Control Manual,” Revision 5 issued in November 2004. Brief Description of Revision: A complete revision to reflect the recent changes in compliance requirements with 10 CFR 835, and for use as a reference document for Tenant Organization Radiological Protection Programs.

  11. Radiological control of food importation products

    International Nuclear Information System (INIS)

    Aguirre G, J.

    2003-01-01

    Nowadays exists the possibility of marketing products possibly polluted with radioactive isotopes, by that some countries like Mexico, they have been given to the task of creating legal bases and the necessary infrastructure with the end of carrying out the radiological surveillance of nutritious import products. In this work the legal bases that our country has established for the radiological control are presented besides the results of this radiological control carried out through the gamma spectroscopy analysis of nutritious import products sent to our country through diverse companies that import foods produced mainly in European countries. (Author)

  12. Radiological contamination control training for laboratory research

    International Nuclear Information System (INIS)

    1997-02-01

    This program management guide describes the proper implementation standard for core training as outlined in the DOE Radiological Control (RadCon) Manual. The guide is to assist those individuals, both within the Department of Energy (DOE) and Managing and Operating (M and O) contractors, identified as having responsibility for implementing the core training recommended by the RadCon Manual. The management guide is divided into the following sections: introduction; instructional materials development; training program standards and policies; and course-specific information. The goal of the core training program is to provide a standardized, baseline knowledge for those individuals completing the core training. Standardization of the knowledge provides personnel with the information necessary to perform their assigned duties at a predetermined level of expertise. Implementing a core training program ensures consistent and appropriate training of personnel

  13. Radiological Control Technician: Phase 1, Site academic training lesson plans

    International Nuclear Information System (INIS)

    1992-10-01

    This volume provides lesson plans for training radiological control technicians. Covered here is basic radiological documentation, counting errors, dosimetry, environmental monitoring, and radiation instruments

  14. Radiological Control Technician: Phase 1, Site academic training study guides

    International Nuclear Information System (INIS)

    1992-10-01

    This volume is a study guide for training Radiological Control Technicians. Provided herein are support materials for learning radiological documentation, communication systems, counting errors and statistics, dosimetry, contamination control, airborne sampling program methods, respiratory protection, radiological source control, environmental monitoring, access control and work area setup, radiological work coverage, shipment and receipt for radioactive material, radiological incidents and emergencies, personnel decontamination, first aid, radiation survey instrumentation, contamination monitoring, air sampling, and counting room equipment

  15. A quality control manual for oral radiology

    International Nuclear Information System (INIS)

    Peixoto, J.E.; Ferreira, R.S.; Bessa, S.O.; Domingues, C.; Gomes, C.A.; Oliveira, S.L.G.; Ortiz, J.A.P.

    1988-01-01

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.) [pt

  16. Radiological control in fires involving radiation sources

    International Nuclear Information System (INIS)

    Franco, J.O.A.; Coelho, C.P.

    1984-01-01

    The copies used during the chatter by techniques from CDTN in the I Mineiro Symposium of Fire Engineering, are presented. The chatter was based on emergency radiation control course, given by CDTN. Basic concepts, such as nuclear physics fundaments, radiation nature and detection, radiation protection and practical aspects of radiological fire emergency, were enphasized. (M.C.K.) [pt

  17. Internal Controlling of a Radiology Department.

    Science.gov (United States)

    Frewer, W; Busch, H P

    2015-11-01

    Caused by legal reform initiatives there is a continuous need to increase effectiveness and efficiency in hospitals and surgeries, and thus to improve processes.Consequently the successful management of radiological departments and surgeries requires suitable structures and optimization processes to make optimization in the fields of medical quality, service quality and efficiency possible.In future in the DRG System it is necessary that the organisation of processes must focus on the whole clinical treatment of the patients (Clinical Pathways). Therefore the functions of controlling must be more established and adjusted. On the basis of select Controlling instruments like budgeting, performance indicators, process optimization, staff controlling and benchmarking the target-based and efficient control of radiological surgeries and departments is shown. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Process management and controlling in diagnostic radiology

    International Nuclear Information System (INIS)

    Gocke, P.; Debatin, J.F.; Duerselen, L.F.J.

    2002-01-01

    Systematic process management and efficient quality control is rapidly gaining importance in our healthcare system. What does this mean for diagnostic radiology departments?To improve efficiency, quality and productivity the workflow within the department of diagnostic and interventional radiology at the University Hospital of Essen were restructured over the last two years. Furthermore, a controlling system was established. One of the pursued aims was to create a quality management system as a basis for the subsequent certification according to the ISO EN 9001:2000 norm.Central to the success of the workflow reorganisation was the training of selected members of the department's staff in process and quality management theory. Thereafter, a dedicated working group was created to prepare the reorganisation and the subsequent ISO certification with the support of a consulting partner. To assure a smooth implementation of the restructured workflow and create acceptance for the required ISO-9001 documentation, the entire staff was familiarized with the basic ideas of process- and quality-management in several training sessions.This manuscript summarizes the basic concepts of process and quality management as they were taught to our staff. A direct relationship towards diagnostic radiology is maintained throughout the text. (orig.) [de

  19. Primary contention 12RU1 radiological control

    International Nuclear Information System (INIS)

    Padilla C, I.

    2007-01-01

    In the primary contention of the Laguna Verde central reactors those are located the main components and control and safety systems related directly with the reactor vessel. Space, accesses, location, maneuvers, armor-plating, movements of components and radiological conditions require of a constant attention to maintain the control of the activities during a fuel reload period. Knowledge, analysis, strategies and attention to the detail in the preparation stages and execution of the fuel reload are fundamental to sum up the objectives. The reload stop 12 of the Unit 1, it required a specific attention in the radiation source due to the addition of noble metals and hydrogen to the vessel internals that generated an increment in the soluble elements of Cobalt and that it was reflected in the radiation fields in the primary contention. Movement of armor-plating of the structures of the biological armor-plating demand to establish new strategies in the control of activities for the next fuel reloads. The analysis and control of the relief valves safety of the reactor vessel, of the exchange of the activation mechanisms of the control bars, as well as of the isolation valves of main vapor and of flow control valves of the reactor recirculation system, its required of a particular attention due to their particular radiological environment, in a brief time space. The importance of this work is located in the detail of critical activities to fulfill the established goals, with successes that can be optimized, and improvement areas that require of investigation and analysis for the implementation of new technologies tend toward to the dose optimization. The reload stop 12 of the unit 1 conclude with 2.43 Sv-person in a period of 27.5 days. (Author)

  20. Radiological Control Technician: Standardized technician Qualification Standard

    International Nuclear Information System (INIS)

    1992-10-01

    The Qualification Standard states and defines the knowledge and skill requirements necessary for successful completion of the Radiological Control Technician Training Program. The standard is divided into three phases: Phase I concerns RCT Academic training. There are 13 lessons associated with the core academics program and 19 lessons associated with the site academics program. The staff member should sign the appropriate blocks upon successful completion of the examination for that lesson or group of lessons. In addition, facility specific lesson plans may be added to meet the knowledge requirements in the Job Performance Measures (JPM) of the practical program. Phase II concerns RCT core/site practical (JPMs) training. There are thirteen generic tasks associated with the core practical program. Both the trainer/evaluator and student should sign the appropriate block upon successful completion of the JPM. In addition, facility specific tasks may be added or generic tasks deleted based on the results of the facility job evaluation. Phase III concerns the oral examination board successful completion of the oral examination board is documented by the signature of the chairperson of the board. Upon completion of all of the standardized technician qualification requirements, final qualification is verified by the student and the manager of the Radiological Control Department and acknowledged by signatures on the qualification standard. The completed Qualification Standard shall be maintained as an official training record

  1. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  2. Radiological characterization of spent control rod assemblies

    International Nuclear Information System (INIS)

    Lepel, E.A.; Robertson, D.E.; Thomas, C.W.; Pratt, S.L.; Haggard, D.L.

    1995-10-01

    This document represents the final report of an ongoing study to provide radiological characterizations, classifications, and assessments in support of the decommissioning of nuclear power stations. This report describes the results of non-destructive and laboratory radionuclide measurements, as well as waste classification assessments, of BWR and PWR spent control rod assemblies. The radionuclide inventories of these spent control rods were determined by three separate methodologies, including (1) direct assay techniques, (2) calculational techniques, and (3) by sampling and laboratory radiochemical analyses. For the BWR control rod blade (CRB) and PWR burnable poison rod assembly (BPRA), 60 Co and 63 Ni, present in the stainless steel cladding, were the most abundant neutron activation products. The most abundant radionuclide in the PWR rod cluster control assembly (RCCA) was 108m Ag (130 yr halflife) produced in the Ag-In-Cd alloy used as the neutron poison. This radionuclide will be the dominant contributor to the gamma dose rate for many hundreds of years. The results of the direct assay methods agree very well (±10%) with the sampling/radiochemical measurements. The results of the calculational methods agreed fairly well with the empirical measurements for the BPRA, but often varied by a factor of 5 to 10 for the CRB and the RCCA assemblies. If concentration averaging and encapsulation, as allowed by 10CFR61.55, is performed, then each of the entire control assemblies would be classified as Class C low-level radioactive waste

  3. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  4. Proposal of inspection methodology for environment radiological control

    International Nuclear Information System (INIS)

    Martins, Nadia Soido Falcao

    2005-01-01

    The Radiation Protection and Dosimetry Institute (IRD) of the Brazilian Nuclear Energy Commission (CNEN) is in charge of verifying that the self-monitoring operator is effective to control the radiological quality of environmental around the nuclear facilities and carried out in accordance with the regulatory requirements. While a long time, the verification of compliance was kept by the conduction of large scale monitoring programs around all the authorized installations. The IRD decided to reformulate its performance behavior, starting another kind of control program, due to the number increase of nuclear installations and the diversity of activities conducted by the operators. This program, so-called Monitoring Control Program (PCM) is a regulatory activity developed by the Environmental Impact Assessment Service (SEAIA) of IRD and has the aim of check the effectiveness of authorized self-control. Actually the regulatory control of environmental radiological integrity around the authorized nuclear installation essentially depends on the effectiveness of regulatory inspections fulfilled by the SEAIA/IRD. Due to the implementation of modern practices of management in the IRD, specially the quality management system on regulatory inspection activities, emerged the need of unify these actions. It was also necessary to establish standard procedures required for inspection conduction. This work proposes one methodology for the inspections of environmental radiological control suitable to assure the compliance and effectiveness of environmental and effluent monitoring programs conducted by the operator, through the systematic verification of compliance and data quality assessment. The proposed methodology seeks to attend the appeals for high control standards of environment protection and public health. Here, we presented as products of this work: The inspection handbook and checklists for inspections; one framework for sampling, handling, recording and reporting of

  5. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  6. Access control and confidentiality in radiology

    Science.gov (United States)

    Noumeir, Rita; Chafik, Adil

    2005-04-01

    A medical record contains a large amount of data about the patient such as height, weight and blood pressure. It also contains sensitive information such as fertility, abortion, psychiatric data, sexually transmitted diseases and diagnostic results. Access to this information must be carefully controlled. Information technology has greatly improved patient care. The recent extensive deployment of digital medical images made diagnostic images promptly available to healthcare decision makers, regardless of their geographic location. Medical images are digitally archived, transferred on telecommunication networks, and visualized on computer screens. However, with the widespread use of computing and communication technologies in healthcare, the issue of data security has become increasingly important. Most of the work until now has focused on the security of data communication to ensure its integrity, authentication, confidentiality and user accountability. The mechanisms that have been proposed to achieve the security of data communication are not specific to healthcare. Data integrity can be achieved with data signature. Data authentication can be achieved with certificate exchange. Data confidentiality can be achieved with encryption. User accountability can be achieved with audits. Although these mechanisms are essential to ensure data security during its transfer on the network, access control is needed in order to ensure data confidentiality and privacy within the information system application. In this paper, we present and discuss an access control mechanism that takes into account the notion of a care process. Radiology information is categorized and a model to enforce data privacy is proposed.

  7. Massive radiological releases profoundly differ from controlled releases

    International Nuclear Information System (INIS)

    Pascucci-Cahen, Ludivine; Patrick, Momal

    2013-01-01

    In this article, the authors report identification and assessment of different types of costs associated with nuclear accidents. They first outline that these cost assessments must be as exhaustive or comprehensive as possible. While referring to past accidents, they define the different categories of costs: on-site costs (decontamination and dismantling, electricity not produced on the site), off-site costs (health costs, psychological costs, farming losses), image-related costs (impact on food and farm product exports, decrease of other exports), costs related to energy production, costs related to contaminated areas (refugees, lands). They give an assessment of a severe nuclear accident (i.e. an accident with important but controlled radiological releases) in France and outline that it would be a national catastrophe which could be however managed. They discuss the possible variations of the estimated costs. Then, they show that a major accident (i.e. an accident with massive radiological releases) in France would be an unmanageable European catastrophe because of the radiological consequences, of high economic costs, and of huge losses

  8. Recommended radiological controls for tritium operations

    International Nuclear Information System (INIS)

    Mansfield, G.

    1992-01-01

    This informal report presents recommendations for an adequate radiological protection program for tritium operations. Topics include hazards analysis, facility design, personnel protection equipment, training, operational procedures, radiation monitoring, to include surface and airborne tritium contamination, and program management

  9. Radiological monitoring. Controlling surface water pollution

    International Nuclear Information System (INIS)

    Morin, Maxime

    2018-01-01

    Throughout France, surface waters (from rivers to brooks) located at the vicinity of nuclear or industrial sites, are subject to regular radiological monitoring. An example is given with the radiological monitoring of a small river near La Hague Areva's plant, where contaminations have been detected with the help of the French IRSN nuclear safety research organization. The sampling method and various measurement types are described

  10. Nevada Test Site Radiological Control Manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2010-02-09

    This document supersedes DOE/NV/25946--801, “Nevada Test Site Radiological Control Manual,” Revision 0 issued in October 2009. Brief Description of Revision: A minor revision to correct oversights made during revision to incorporate the 10 CFR 835 Update; and for use as a reference document for Tenant Organization Radiological Protection Programs.

  11. Radiological control criteria for materials considered for recycle and reuse

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Hill, R.L.; Aaberg, R.L.; Wallo, A. III.

    1995-01-01

    Pacific Northwest Laboratory (PNL) is conducting technical analyses to support the U.S. Department of Energy (DOE), Office of Environmental Guidance, Air, Water, and Radiation Division (DOE/EH-232) in developing radiological control criteria for recycling or reuse of metals or equipment containing residual radioactive contamination from DOE operations. The criteria, framed as acceptable concentrations for release of materials for recycling or reuse, are risk-based and were developed through analysis of generic radiation exposure scenarios and pathways. The analysis includes evaluation of relevant radionuclides, potential mechanisms of exposure, and non-health-related impacts of residual radioactivity on electronics and film. The analysis considers 42 key radionuclides that DOE operations are known to generate and that may be contained in recycled or reused metals or equipment. The preliminary results are compared with similar results reported by the International Atomic Energy Agency, by radionuclide grouping. (author)

  12. Radiological control criteria for materials considered for recycle and reuse

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Hill, R.L.; Aaberg, R.L.; Wallo, A. III

    1994-11-01

    Pacific Northwest Laboratory (PNL) is conducting technical analyses to support the US Department of Energy (DOE), Office of Environmental Guidance, Air, Water, and Radiation Division (DOE/EH-232) in developing radiological control criteria for recycling or reuse of metals or equipment containing residual radioactive contamination from DOE operations. The criteria, framed as acceptable concentrations for release of materials for recycling or reuse, are risk-based and were developed through analysis of generic radiation exposure scenarios and pathways. The analysis includes evaluation of relevant radionuclides, potential mechanisms of exposure, and non-health-related impacts of residual radioactivity on electronics and film. The analysis considers 42 key radionuclides that DOE operations are known to generate and that may be contained in recycled or reused metals or equipment. Preliminary results are compared with similar results reported by the International Atomic Energy Agency, by radionuclide grouping

  13. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  14. Quality Control in Diagnostic Radiology: Experiences and Achievements

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Salleh; Muhammad Jamal Md Isa

    2015-01-01

    Malaysian Nuclear Agency through its Medical Physics Group has been providing Quality Control (QC) services for medical X-ray apparatus used in diagnostic radiology to private clinics and hospitals since the year 1997. The Medical Physics Groups services is endorsed by the Malaysian Ministry Of Health (MOH) and is in accordance with the Malaysian Standard MS 838 and the Atomic Energy Licensing Act, 1984. Until today, the scopes of testing services also include all types of medical x-ray apparatus. The quality control (QC) in diagnostic radiology is considered as part of quality assurance program which provide accurate diagnostic information at the lowest cost and the least exposure of the patients to radiation. Many experience and obstacles were faced by Medical Physics Group. This paper will discuss the experiences and achievements of providing QC service from early stage until now so that it can be shared by the citizens of the Malaysian Nuclear Agency. The results of quality assurance inspection of all types of X-ray apparatus for medical conducted by Agency Nuclear Malaysia will be presented in brief. (author)

  15. Quality control in dental diagnostic radiology : anomalous in the use of radiological equipment

    International Nuclear Information System (INIS)

    Alcaraz, M.; Martinez-Beneyto, Y.; Jodar, S.; Velasco, E.; Garcia-Vera, M. C.

    2004-01-01

    7,176 official quality control reports on dental diagnostic radiology were studied, relating to dental clinics located in 37 Spanish provinces covering 16 different autonomous Regions. The reports were issued as a result of the entry into force of Royal Decree 2071/1995 on quality control in General Diagnostic Radiology facilities, this Royal Decree was replaced by R. D. 1976/1999. The reports were writen by the UTPR (Technical Unit of Radiological Protection) Agsigma S. A. L., a company approved by the Nuclear Safety Council, and they correspond with the official reports issued during 1996-2001. This meants that a 5-year period has been monitored in order to observe the impacts of the establlishment of this legislation on quality control in intraoral dental diagnostic radiology facilities. The results show that 72.79% of the reports checked in 2001 would comply with the European Union's official recommendation (70 kVp, 8 mA> 1.5 mm of Al and 20 cm collimator length). Significant alterations have detected in a third (30.59%) of the radiological equipment. (Author) 36 refs

  16. Quality Control in Diagnostic Radiology in the Netherlands (invited paper)

    International Nuclear Information System (INIS)

    Zoetelief, J.

    1998-01-01

    Application of the general principles of radiation protection to medical diagnostic radiology implies that each procedure using X rays or radionuclides is to be justified and optimised. Optimisation in diagnostic radiology implies that the radiation burden to the patient should be as low as possible, but compatible with the image quality necessary to obtain an adequate diagnosis or to guide treatment. Quality control of equipment is a prerequisite for achieving optimisation in diagnostic radiology. This was especially recognised for mammography as employed for breast cancer screening. Existing legislation in the Netherlands includes only a few criteria for equipment used in diagnostic radiology. In addition, the criteria are not all operational and measurement methods are lacking. Therefore, upon the initiative of the Dutch Ministry of Health, Welfare and Sports, the relevant professional societies, in collaboration with the former TNO Centre for Radiological Protection and Dosimetry, formulated eleven guidelines for quality control of equipment used in diagnostic radiology, including test procedures, test frequencies and limiting values. The implementation of quality control of equipment was included in the 1984 European Directive (84/466/Euratom) laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. In the most recent European Directive on medical exposure (97/43/Euratom) the importance of quality control is stressed. In addition, the latter EC directive proposes the use of diagnostic reference levels for limiting the risks for patients undergoing diagnostic radiology. In the Netherlands preliminary reference levels for various procedures employed in diagnostic radiology are suggested. Finally, methods applied in the Netherlands for assessment of image quality are discussed. (author)

  17. Nevada Test Site Radiological Control Manual, Revision 1

    International Nuclear Information System (INIS)

    2010-01-01

    This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 0 issued in October 2009. Brief Description of Revision: A minor revision to correct oversights made during revision to incorporate the 10 CFR 835 Update; and for use as a reference document for Tenant Organization Radiological Protection Programs. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. The NTS is located in Nye County, Nevada. The NTS is located approximately 105 kilometers (65 miles) northwest of Las Vegas. It is a remote facility that covers approximately 3,500 square kilometers (1,375 square miles) of land. The dimensions of the NTS vary from 46 to 56 kilometers (28 to 35 miles) in width (eastern to western border) and from 64 to 88 kilometers (40 to 55 miles) in length (northern to southern border). The NTS is surrounded to the west, north, and east by additional thousands of acres of land withdrawn from the public domain for use as a protected wildlife range and as a military gunnery range. These public exclusion areas comprise the Nellis Air Force Range complex, previously designated as the Nellis Air Force Base Bombing and Gunnery Range, and the Tonopah Test Range. These two areas provide a buffer zone between the test areas and public lands administered by the Federal Bureau of Land

  18. Radiology

    International Nuclear Information System (INIS)

    Sykora, A.

    2006-01-01

    In this text-book basic knowledge about radiology, biomedical diagnostic methods (radiography, computer tomography), nuclear medicine and safety and radiation protection of personnel on the radiodiagnostic place of work are presented

  19. Nuclear Energy Agency task group on Radiological Characterisation for Decommissioning of Nuclear Installations

    International Nuclear Information System (INIS)

    Larsson, Arne; Weber, Inge

    2016-01-01

    Radiological characterisation plays a significant role in the process of decommissioning of shut-down nuclear facilities in order to ensure the protection of the environment and radiation safety. At all stages of a decommissioning programme or project, adequate radiological characterisation is of crucial importance, not least from a material and waste perspective. The radiological characterisation is a key element for planning, controlling and optimising decommissioning and dismantling activities. Experience has shown that data and information from the operation of a facility can - supplemented by recently collected and analysed data and information - be of crucial importance for decisions on waste management and for characterisation of radioactive waste. Once the dismantling has been done, some information may be hard, costly or even impossible to obtain later in the waste management process. This was the reason why the Working Party on Decommissioning and Dismantling (WPDD) of the OECD Nuclear Energy Agency (NEA) decided in late 2013 to extend the mandate of the Task Group on Radiological Characterisation and Decommissioning (TGRCD) for a second phase focusing on nuclear facility characterisation from a waste and material end-state perspective whereas the first phase focused on overall strategies of radiological characterisation. This paper gives an overview of the activities and findings within both phases up to now. (authors)

  20. Radiological control aspects of the fabrication of the Light Water Breeder Reactor core (LWBR Development Program)

    International Nuclear Information System (INIS)

    Schultz, B.G.

    1979-05-01

    A description is presented of the radiological control aspects of the fabrication of the Light Water Breeder Reactor (LWBR) core. Included are the radiological control criteria applied for the design and use of fabrication facilities, the controls and limits imposed to minimize radiaion exposure to personnel, and an evaluation of the applied radiological program in meeting the program objectives. The goal of the LWBR program is to develop the technology to breed in light water reactors so that nuclear fuel may be used significantly more efficiently in these reactors. This technology is being developed by designing and fabricating a breeder reactor core, utilizing thoria (ThO 2 ) and binary thoria--urania (ThO 2 - 233 UO 2 ) fuel, to be operated in the existing pressurized water reactor plant owned by the Department of Energy at Shippingport, Pennsylvania

  1. Nuclear energy in Europe and its radiological consequences

    International Nuclear Information System (INIS)

    Kellerer, A.M.

    1993-01-01

    In a popular way, the author deals with the impacts of the Chernobyl reactor accident, and with the scientific relevance of reactions to and discussions about the consequences of peaceful nuclear energy use in Germany. He arrives at the conclusion that the use of nuclear energy in Europe does not have any radiological consequences for its population. Radioactive fission product release during normal operation is completely irrelevant in his view; a controversial problem being the potential release in the case of major accidents. According to the author, however, it would be irrational to put an end to the use of nuclear energy in an area where it shows a high degree of safety, and leave it on its own where it is threatening already now. (orig./HP) [de

  2. Decision theory applied to image quality control in radiology.

    Science.gov (United States)

    Lessa, Patrícia S; Caous, Cristofer A; Arantes, Paula R; Amaro, Edson; de Souza, Fernando M Campello

    2008-11-13

    The present work aims at the application of the decision theory to radiological image quality control (QC) in diagnostic routine. The main problem addressed in the framework of decision theory is to accept or reject a film lot of a radiology service. The probability of each decision of a determined set of variables was obtained from the selected films. Based on a radiology service routine a decision probability function was determined for each considered group of combination characteristics. These characteristics were related to the film quality control. These parameters were also framed in a set of 8 possibilities, resulting in 256 possible decision rules. In order to determine a general utility application function to access the decision risk, we have used a simple unique parameter called r. The payoffs chosen were: diagnostic's result (correct/incorrect), cost (high/low), and patient satisfaction (yes/no) resulting in eight possible combinations. Depending on the value of r, more or less risk will occur related to the decision-making. The utility function was evaluated in order to determine the probability of a decision. The decision was made with patients or administrators' opinions from a radiology service center. The model is a formal quantitative approach to make a decision related to the medical imaging quality, providing an instrument to discriminate what is really necessary to accept or reject a film or a film lot. The method presented herein can help to access the risk level of an incorrect radiological diagnosis decision.

  3. Emergency response during the radiological control of scraps in Cuba

    International Nuclear Information System (INIS)

    Ramos Viltre, Enma O.; Cardenas Herrera, Juan; Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Fernandez Gomez, Isis M.; Caveda Ramos, Celia; Carrazana, Jorge; Barroso Perez, Idelisa

    2008-01-01

    In the last few years, in the international scene, incidents have been reported due to the presence of radioactive materials in the scrap. This reality has motivated the adoption of measures of radiological security, due to the implications that these incidents have for the public and the environment, as well as for the international trade. Among theses actions is the implementation of the radiological control of scrap, with the additional requirement that this control has to be implemented in the framework of a Quality Management Program.Taking into account the international experience, our institution designed and organized in 2002 a national service for the radiological monitoring of scrap, being the clients the main exporting and trading enterprises of this material in the country. During these years, several contaminated materials have been detected, causing incidents that activated the radiological emergency response system. In this sense, since some years ago, our country has been working in the implementation of a national and ministerial system for facing and mitigating the consequences of accidental radiological situations, conjugating efforts and wills from different national institutions with the leadership of the Center of Radiation Protection and Hygiene (CPHR) and the Center of Nuclear Security (CNSN) in correspondence with the social responsibility assigned to the them. These incidents propitiate to have not only a system of capacity and quick response oriented to limit the exposure of people, to control the sources, to mitigate the consequences of the accident and to reestablish the conditions of normality, but also a previous adequate planning that guarantees the speed and effectiveness of it. In these work the experiences reached by the specialists of the CPHR from Cuba during the occurrence of an incident in the execution of the service of radiological monitoring of scraps are exposed. (author)

  4. Challenges in setting up quality control in diagnostic radiology ...

    African Journals Online (AJOL)

    Journal Home > Vol 24, No 4 (2015) >. Log in or ... Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the ... Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study.

  5. Radiology

    International Nuclear Information System (INIS)

    Meyers, M.A.

    1989-01-01

    This paper reports on disease processes originating within the alimentary tract, may extend through the extraperitoneal spaces, and abnormalities primarily arising within other extraperitoneal sites may significantly affect the bowel. Symptoms and signs may be obscure, delayed, or nonspecific, and the area is generally not accessible to auscultation, palpation, or percussion. Radiologic evaluation thus plays a critical role

  6. Quality Control Assessment of Radiology Devices in Kerman Province, Iran

    Directory of Open Access Journals (Sweden)

    Zahra Jomehzadeh

    2016-03-01

    Full Text Available Introduction Application of quality control (QC programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests were performed on 28 conventional radiographic X-ray units in Kerman governmental hospitals, based on the protocols and criteria recommended by the Atomic Energy Organization of Iran (AEOI, using a calibrated Gammex QC kit. Each section of the QC kit incorporated different models. Results Based on the findings, kVp accuracy, kVp reproducibility, timer accuracy, timer reproducibility, exposure reproducibility, mA/timer linearity, and half-value layer were not within the acceptable limits in 25%, 4%, 29%, 18%, 11%, 12%, and 7% of the evaluated units (n=28, respectively. Conclusion As radiographic X-ray equipments in Kerman province are relatively old with a high workload, it is recommended that AEOI modify the current policies by changing the frequency of QC test implementation to at least once a year.

  7. Noise control of radiological monitoring equipment

    International Nuclear Information System (INIS)

    Rubick, R.D.; Stevens, W.W.; Burke, L.L.

    1998-01-01

    Although vacuum pumps on continuous air monitors (CAMs) do not produce noise levels above regulatory limits, engineering controls were used to establish a safer work environment. Operations performed in areas where CAMs are located are highly specialized and require precision work when handling nuclear materials, heavy metals, and inert gases. Traditional methods for controlling noise such as enclosing or isolating the source and the use of personal protection equipment were evaluated. An innovative solution was found by retrofitting CAMs with air powered multistage ejectors pumps. By allowing the air to expand in several chambers to create a vacuum, one can eliminate the noise hazard altogether. In facilities with adequate pressurized air, use of these improved ejector pumps may be a cost-effective replacement for noisy vacuum pumps. A workplace designed or engineered with noise levels as low as possible or as close to background adds to increased concentration, attention to detail, and increased production

  8. Basic radiological studies contamination control experiments

    International Nuclear Information System (INIS)

    Duce, S.W.; Winberg, M.R.; Freeman, A.L.

    1989-09-01

    This report describes the results of experiments relating to contamination control performed in support of the Environmental Restoration Programs Retrieval Project. During the years 1950 to 1970 waste contaminated with plutonium and other transuranic radionuclides was disposed of in shallow land-filled pits and trenches at the Idaho National Engineering Laboratory. Due to potential for migration of radionuclides to an existing aquifer the feasibility of retrieving and repackaging the waste for placement in a final repository is being examined as part of a retrieval project. Contamination control experiments were conducted to determine expected respirable and nonrespirable plutonium contaminated dust fractions and the effectiveness of various dust suppression techniques. Three soil types were tested to determine respirable fractions: Rocky Flats Plant generic soil, Radioactive Waste Management Complex generic soil, and a 1:1 blend of the two soil types. Overall, the average respirable fraction of airborne dust was 5.4% by weight. Three contamination control techniques were studied: soil fixative sprays, misting agents, and dust suppression agents. All of the tested agents proved to be effective in reducing dust in the air. Details of product performance and recommended usage are discussed

  9. Clearance of slightly radioactive material from radiological control in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    1995-01-01

    Clearance from radiological control of slightly radioactive material arising from operation or decommissioning of nuclear installations has been practiced in Germany for nearly two decades. Meanwhile, for the clearance of metal generally approved and applicable recommendations for clearance levels have been issued. For other materials like building waste, case-by-case decisions are made by the state licensing authorities. Efforts to implement consistent sets of clearance levels for all kinds of material are under way. As several decommissioning projects will soon generate large amounts of materials from dismantling, a solution needs to be reached soon. The legal framework in Germany governing the use of atomic energy consists of the Atomic Energy Act and several ordinances. Rules and guidelines including the recommendations of the German Commission for Radiation Protection (SSK) exist on a lower level and are not legally binding. Several generic studies for the derivation of clearance levels for metals and building debris with alpha, beta, and gamma contamination have been performed on behalf of the Federal Ministry for Environment, Nature Conservation and Nuclear Safety, which oriented themselves on an individual dose of 10 microSv/a in agreement with IAEA recommendations. Stochastic models have been used for establishing the connection between specific activity of the material to be released and the resulting individual doses, with significant advantages over deterministic scenarios. In the future, for new SSK recommendations or an ordinance on clearance, the increase of masses from demolition of installations, higher recycling rates in the conventional sector and harmonization with international regulations and standards have to be taken into account

  10. Basic quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Wikstrom, Erik

    2016-01-01

    Along the route toward regular performance of Quality Control in the Diagnostic Imaging sector there are a number of balances to negotiate: Patient/Staff safety considerations vs Regulatory compliance vs Performance of modern equipment vs Clinic's Productivity. At first glance these ambitions may seem in conflict. The tests performed to meet regulatory requirements may or may not bear any semblance to real clinical measurement scenarios. And the process of collecting the data from the quality assurance tests may induce a system down- time that adversely affects the clinic's overall productivity. Furthermore, the time it takes to complete the analysis of the test data and provide the report required to take the facility back into operation is time wasted for patients waiting for a diagnostic imaging exam

  11. Quality control in diagnostic radiology: experience and challenges

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Mohd Ramli Arshad; Mohd Khalid Matori; Muhammad Jamal Md Isa; Husaini Salleh; Abdullah Tahir Aliyasak; Zainal Jamaluddin; Hasrul Hisham Hussain

    2005-01-01

    Malaysian Institute for Nuclear Technology Research through its Medical Physics Group has been providing Quality Control (QC) services for medical x-ray apparatus used in diagnostic radiology to private clinics and hospitals since the year 1997. The quality control (QC) in diagnostic radiology is considered as part of quality assurance program which provide accurate diagnostic information at the lowest cost and the least exposure of the patients to radiation. Many experience and obstacles were faced by Medical Physics Group. This paper will discuss on some of the experiences and challenges that could be shared together with MINT staff especially in the safety aspect related to electrical and mechanical, radiation protection, performance and standard. The challenging in administrative aspect also will discuss. (Author)

  12. Atomic Energy Control Act

    International Nuclear Information System (INIS)

    1970-01-01

    This act provides for the establishment of the Atomic Energy Control Board. The board is responsible for the control and supervision of the development, application and use of atomic energy. The board is also considered necessary to enable Canada to participate effectively in measures of international control of atomic energy

  13. Quality Control Assessment of Radiology Devices in Kerman Province, Iran

    OpenAIRE

    Zahra Jomehzadeh; Ali Jomehzadeh; Mohammad Bagher Tavakoli

    2016-01-01

    Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests were performed on 28 conventional radiographic X-ray units in Kerman governmental hospitals, based ...

  14. The significance of radiological control documentation in litigation

    International Nuclear Information System (INIS)

    Lodde, G.M.; Murphy, T.D.

    1988-01-01

    Commercial nuclear facilities accumulate radiological control program data and documents generated and retained pursuant to regulatory, license, and technical specification requirements. During and following the Three Mile Island Unit 2 (TMI-2) accident, many documents were produced that would not normally have been produced. Shortly after the accident, the US Nuclear Regulatory Commission (NRC) issued an order requiring the retention of all data, including documentary material and physical samples relating to the TMI-2 accident (44 Fed. Reg. 30788, May 29, 1979). Three years later, the NRC vacated the requirement to retain catalogued physical samples, provided the radioactivity data had been properly recorded, allowing disposal of many samples. After the TMI-2 accident, GPU Nuclear Corporation (GPU) designed and implemented an effective and efficient record management program for TMI. This Computer-Assisted Records and Information Retrieval System (CARIRS) was developed to assess the official record for TMI, which is maintained as a microform. GPU also retains hard copies of selected radiological control documents for potential litigation. This paper describes the use of radiological control documentation in the postaccident litigation and the magnitude of document production required to support that litigation

  15. Assessment of the radiological control at the IPEN radioisotope production facility

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, J.C.G.G.; Sanches, M.P.; Rodrigues, D.L.; Campos, D.; Nogueira, P.R.; Damatto, S.R.; Pecequilo, B.R.S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The main objective of this work is to evaluate the 2013 annual radiological control results in the radiopharmaceuticals areas of the Nuclear and Energy Research Institute, IPEN/SP, Brazil and the environmental radiological impact, resulting from the practices there performed. The current evaluation was performed through the analysis of the results obtained from occupational and environmental monitoring with air samplers and TL dosimeters. All monitoring results were compared with the limits established by national standards. The radionuclides detected by air sampling (in activated carbon cartridges and filter paper) at the workplace during radioisotope production were {sup 131}I, {sup 99m}Tc and {sup 99}Mo, with activities concentrations values below the annual limits values. For the radioactive gaseous releases (Bq/m{sup 3} ), the activities concentrations also remained below the maximum admissible values, excepting to {sup 125}I release due to an unusual event occurred in a researcher laboratory, but the radiological impact to environmental was no significant. The occupational monitoring assessment was confirmed by the Environmental Radiological Monitoring Program results with air samplers and TL dosimeters. The mean annual background radiation at IPEN in 2013, according to the Environmental Radiological Monitoring Program results was 1.06 mSv. y{sup -1} , below the ICRP 103 recommended limit of 20 mSv.y{sup -1} for workers. (author)

  16. Patient dosimetry and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Suliman, I. I.

    2007-08-01

    In the first part of the study, entrance surface doses (ESDs) to patients in radiography were estimated from x-ray tube output parameters for a sample of 346 radiographs. The mean ESDs estimated in the hospitals ranged from 0.17 to 0.27 mGy for chest PA, 1.04-2.26 mGy for skull AP/PA, 0.83-1.32 mGy for skull LAT, 1.31-1.89 mGy for pelvis AP, 1.46-3.33 mGy for Lumbar Spine AP and 2.9-9.9 mGy for Lumbar Spine LAT. With the exception of chest PA examination at two hospitals, mean ESDs were found to be within the established international reference doses. In addition, study was performed to compare two methods used for effective dose calculation in diagnostic radiology. Initially, ED values were calculated from ESD values using NRPB-SR262 Monte Carlo data and XDOSE software. Next, the energy imparted to patients was computed using values for entrance skin exposure-area product and half-value layer. Effective doses were then determined from energy imparted using ED/ε conversion factors proposed in the literature. Mean ED values calculated using the two methods were: 21.3-23.4, 14.1-12.8, 7.9-8.5, 232-226, 215-223 and 91-85.6 μSv for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations, respectively. The values obtained were in agreement between themselves and with data reported in the literature. In the second part, a protocol for quality control (QC) tests has been drafted based on various national and international recommendations. Tests were included for various parts of the imaging chain, i.e. x-ray tube and generator; x-ray tube control system; laser printer and display station; image quality and patient dose. Preliminary tolerance levels have been set for the various tests, after initial measurements. To check the suitability of the QC tests and the stated tolerance levels, measurements were made at the University Hospital Gasthuisberg in Leuven, the Netherland, for equipment used for paediatric radiology and a unit used

  17. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  18. Massive radiological releases profoundly differ from controlled releases

    International Nuclear Information System (INIS)

    Pascucci-Cahen, Ludivine; Patrick, Momal

    2012-11-01

    Preparing for a nuclear accident implies understanding potential consequences. While many specialized experts have been working on different particular aspects, surprisingly little effort has been dedicated to establishing the big picture and providing a global and balanced image of all major consequences. IRSN has been working on the cost of nuclear accidents, an exercise which must strive to be as comprehensive as possible since any omission obviously underestimates the cost. It therefore provides (ideally) an estimate of all cost components, thus revealing the structure of accident costs, and hence sketching a global picture. On a French PWR, it appears that controlled releases would cause an 'economical' accident with limited radiological consequences when compared to other costs; in contrast, massive releases would trigger a major crisis with strong radiological consequences. The two types of crises would confront managers with different types of challenges. (authors)

  19. Quality control in the radiological examinations of paediatric patients

    International Nuclear Information System (INIS)

    Gaiba, W.; Rossi, A.; Vos, C.V.; Giacomelli, G.; Galletti, S.; Rimondi, E.

    1985-01-01

    With a view to minimising the dose absorbed by the paediatric patient during radiological investigations, the most usual X-ray examinations performed in paediatrics were checked in order to standardise and optimise the techniques used. The present study deals with the quality control of the X-ray beam used in radiological diagnosis of young patients, particularly considering that hips and pelvis pathologies can be widespread and that very often it is not possible to shield the patient's gonads during the examination. The electrical and geometrical parameters which minimise the absorbed dose but are compatible with obtaining valid diagnostic information are selected. An anthromorphic phantom reproducing bone and lung inhomogeneities was constructed to the average size of a 12-month-old baby. Inside the phantom TLD 4F 100 dosimeters were located in order to evaluate the absorbed doses. The technique which proved more convenient is indicated and suggested for routine work. (author)

  20. Radiology

    International Nuclear Information System (INIS)

    Lissner, J.

    1985-01-01

    Diagnostic radiology is still the foremost of all innovative medical disciplines. This has many advantages but also some handicaps, e.g. the siting problem of medical equipment whose clinical potential is not fully known. This applies in particular to nuclear spin tomography, where the Laender governments and the Scientific Council seen to agree that all universities should have the appropriate equipment as soon as possible in order to intensify interdisciplinary research. Formerly, in the case of computerized tomography, there was less readiness. As a result, the siting of CT equipment is less organically structured. A special handicap of innovative fields is the problem of training and advanced training. The Chamber of Medicine and the Association of Doctors Participating in the Health Insurance Plan have issued regulations aimed at a better standardisation in this field. (orig.) [de

  1. Quality control activities in the environmental radiology laboratory

    International Nuclear Information System (INIS)

    Llaurado, M.; Quesada, D.; Rauret, G.; Tent, J.; Zapata, D.

    2006-01-01

    During the last twenty years many analytical laboratories have implemented quality assurance systems. A quality system implementation requires documentation of all activities (technical and management), evaluation of these activities and its continual improvement. Implementation and adequate management of all the elements a quality system includes are not enough to guarantee quality of the analytical results generated at a time. That is the aim of a group of specific activities labelled as quality control activities. The Laboratori de Radiologia Ambiental (Environmental Radiology Laboratory; LRA) at the University of Barcelona was created in 1984 to carry out part of the quality control assays of the Environmental Radiology Monitoring Programs around some of the Spanish nuclear power plants, which are developed by the Servei Catala d'Activitats Energetiques (SCAR) and the Consejo de Seguridad Nuclear (CSN), organisations responsible for nuclear security and radiological protection. In these kind of laboratories, given the importance of the results they give, quality control activities become an essential aspect. In order to guarantee the quality of its analytical results, the LRA Direction decided to adopt the international standard UNE-EN ISO/IEC 17025 for its internal quality system and to accreditate some of the assays it carries out. In such as system, it is established, the laboratory shall monitor the validity of tests undertaken and data shall be recorded in such a way that trends are detectable. The present work shows the activities carried out in this way by the LRA, which are: Equipment control activities which in the special case of radiochemical techniques include measurement of backgrounds and blanks as well as periodical control of efficiency and resolution. Activities to assure the specifications settled by method validation, which are testing of reference materials and periodical analysis of control samples. Evaluation of the laboratory work quality

  2. Radiological control of food importation products; Control radiologico de productos alimenticios de importacion

    Energy Technology Data Exchange (ETDEWEB)

    Aguirre G, J. [CNSNS, Dr. Barragan 779, 03020 Mexico D.F. (Mexico)]. e-mail: jaguirre@cnsns.gob.mx

    2003-07-01

    Nowadays exists the possibility of marketing products possibly polluted with radioactive isotopes, by that some countries like Mexico, they have been given to the task of creating legal bases and the necessary infrastructure with the end of carrying out the radiological surveillance of nutritious import products. In this work the legal bases that our country has established for the radiological control are presented besides the results of this radiological control carried out through the gamma spectroscopy analysis of nutritious import products sent to our country through diverse companies that import foods produced mainly in European countries. (Author)

  3. The energy control

    International Nuclear Information System (INIS)

    2002-01-01

    Because of strong constraints, the energy control has not been a priority of the public choices. With the market liberalization, the framework of the energy control is modified. But the new program became not sufficient. This study aims to present the necessary new policy of the energy control, which must be integrated in the attitudes and must imply the local government. (A.L.B.)

  4. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  5. Radiological control of contractors' employees - an independent RPA's view

    International Nuclear Information System (INIS)

    Ellis, J.O.; Webb, C.A.

    1995-01-01

    The changing structure of the nuclear industry in the UK is resulting in a significant increase in the number of contracting companies whose employees are engaged in work that would previously have been the sole responsibility of the workforce directly employed by the Site Licence holder. This trend is being given added impetus by the move towards contractorisation and privatisation of significant portions of the industry; for example, the UKAEA is, at the time of writing, divided into three separate organisations responsible for the work in Controlled Areas at several sites. This paper seeks to set out some of the potential and actual radiological problems encountered, together with some suggested solutions. (author)

  6. Shielded chamber control stations: an answer to radiological protection requirements

    International Nuclear Information System (INIS)

    Delaboudiniere, Catherine.

    1979-06-01

    This study, carried out at the radiometallurgy laboratory of the Fontenay-aux-Roses Nuclear Research Centre, is based on an ergonomic approach. It shows that the shielded chamber control station, designed for human protection against ionizing radiations, demands an effort of adaptation on the part of the operator. This station does in fact meet radiological protection obligations but would benefit from certain improvements aimed at reducing the secondary fatigue of manipulators already under the strain of adapting to the machine. Fields in which improvements and/or changes are desirable have been investigated with special reference to telemanipulators. New and better designed instruments will soon appear on the telemanipulator market [fr

  7. Environmental Radiological Impact of Nuclear Power. Monitoring and Control Programs

    International Nuclear Information System (INIS)

    Ramos, L. M.

    2000-01-01

    Radioactive contamination of the environment and public exposure to ionizing radiation may result from releases from programmed or accidental operations in regulated activities, or they may be due to preexisting situations such as contamination caused by past accidents, radioactive rain caused by nuclear tests, or increased natural radioactivity resulting from human activities. In many cases, both the emission sources and the environment should be monitored to determine the risk to the population and verify to what extent the limits and conditions established by competent authorities are being observed. Monitoring can be divided into three categories: monitoring of the emission source, of the receiving medium and of members of the public; individual monitoring of the population is extremely rare and would only be considered when estimated doses substantially exceed the annual public dose limit. In practices likely to produce significant radioactive releases, as is the case of nuclear fuel cycle facilities, the limits and conditions for monitoring and controlling them and the requirements for environmental radiological monitoring are established in the licensing process. Programs implemented during normal operation of the facilities form the basis for monitoring in the event of accidents. in addition to environmental radiological monitoring associated with facilities, different countries have monitoring programs outside the facilities zones of influence, in order to ascertain the nationwide radiological fund and determine possible increases in this fund. In Spain, the facilities that generate radioactive waste have effluent storage, treatment and removal systems and radiological monitoring programs based on site and discharge characteristics. The environmental radiological monitoring system is composed of the network implemented by the owners in the nuclear fuel cycle facilities zones of influence, and by nationwide monitoring networks managed by the Consejo de

  8. Radiological control of the junk exports in Cuba

    International Nuclear Information System (INIS)

    Dominguez L, O.; Capote F, E.; Carrazana G, J.A.; Zerquera, J.T.; Ramos V, O.; Alonso A, D.; Fernandez, I.M.; Caveda R, C.A.; Madrazo M, S.; Barroso P, I.

    2006-01-01

    Even when in Cuba a strict control exists on the radiation sources that enter to the country to be used in the different applications, it can be given the case that sources or contaminated materials that never were under this control due fundamentally to that entered to the country before the same one existed, appear in the junk that is marketed. In our country it is effective the Combined Resolution CITMA-MINCEX dated on April, 2002 that settles down the necessity and obligation that has all that manipulates, imports, exports or process junk of carrying out it a radiological control. From April, 2002 making use of a minimum of resources, an own methodology, a properly qualified personnel and the support of a credited laboratory by the ISO 17025 standard, the radioactivity measurement service in junk belonging to the Center of Protection and Hygiene of the Radiations (CPHR), it has reduced the risks that sources or contaminated materials are found in the junk that is exported in the main exporter companies of this line in Cuba avoiding possible radiological emergency situations that affect the population and the environment. (Author)

  9. Atomic Energy Control Board

    International Nuclear Information System (INIS)

    Blackman, N.S.; Gummer, W.K.

    1982-02-01

    This paper has been prepared to provide an overview of the responsibilities and activities of the Atomic Energy Control Board. It is designed to address questions that are often asked concerning the establishment of the Atomic Energy Control Board, its enabling legislation, licensing and compliance activities, federal-provincial relationships, international obligations, and communications with the public

  10. Study of criteria for foodstuffs control following a radiological emergency

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Min; Park, Sang Hyun; Jeong, Seung Young; Kim, Dong Il [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-04-15

    The foodstuff control standards on APPRE should be applied to emergency situation only, while the Korean Food Stands Codex standards of the Korea Food and Drug Administration (KFDA) should be applied in normal situation. To reflect the lessons learned form the Fukushima accident, the standards of foodstuff control has been studied by surveying newly recommended systems of radiological protection based on reference level commensurated with exposure situations and international trends. Existing standards for restriction on ingestion of foodstuff is based on simple cost-benefit approach and it is confirmed that the projected doses is contributed excessively on the specific food categories. In future, the standards will be revised considering domestic diet feature, nuclide analysis procedure, international standard and the latest recommendation of radiation protection. Also, modification of provisions and standards for foodstuff control of related departments are needed for well integrated national EPR framework.

  11. Radiological control of a microPET/CT laboratory

    International Nuclear Information System (INIS)

    Sarmento, Daniele M.; Sanches, Matias P.; Carneiro, Janete C.G.G.

    2015-01-01

    This paper presents the radiological control of a research laboratory in order to satisfy national standards and international recommendations. The microPET/CT laboratory in IPEN uses an Albira system for research purposes in small animals. This study focuses mainly to carry out an initial radiological evaluation and the exposure situation related with the task. The assessment of workplace conditions and individual exposures constitutes as integral part of the operational monitoring programme. Initially, the radiometric survey in laboratory has been carried out using an ionization chamber Radcal 9010 (10 x 5 - 1800). In addition, nine monitoring points with potential exposure were selected, where thermoluminescent dosimeters, TLDs, of CaSO 4 :Dy, were positioned. The occupationally exposed workers were monthly evaluated for external exposures using TL dosimeters, worn on the surface of the body. For internal exposure, the evaluated period was approximately one year starting on April 2014. The average effective dose of the occupationally exposed workers did not exceed 2.4 mSv in the year of 2014, which is equal to the recording level. The workplace, microPET/CT laboratory, is classified as supervised area and the monitoring results in the evaluated period, are within the dose limits established by national standard, as well as the values obtained in individual control. (author)

  12. NV/YMP radiological control manual, Revision 2

    International Nuclear Information System (INIS)

    Gile, A.L.

    1996-11-01

    The Nevada Test Site (NTS) and the adjacent Yucca Mountain Project (YMP) are located in Nye County, Nevada. The NTS has been the primary location for testing nuclear explosives in the continental US since 1951. Current activities include operating low-level radioactive and mixed waste disposal facilities for US defense-generated waste, assembly/disassembly of special experiments, surface cleanup and site characterization of contaminated land areas, and non-nuclear test operations such as controlled spills of hazardous materials at the hazardous Materials (HAZMAT) Spill Center (HSC). Currently, the major potential for occupational radiation exposure is associated with the burial of low-level nuclear waste and the handling of radioactive sources. Planned future remediation of contaminated land areas may also result in radiological exposures. The NV/YMP Radiological Control Manual, Revision 2, represents DOE-accepted guidelines and best practices for implementing Nevada Test Site and Yucca Mountain Project Radiation Protection Programs in accordance with the requirements of Title 10 Code of Federal Regulations Part 835, Occupational Radiation Protection. These programs provide protection for approximately 3,000 employees and visitors annually and include coverage for the on-site activities for both personnel and the environment. The personnel protection effort includes a DOE Laboratory Accreditation Program accredited dosimetry and personnel bioassay programs including in-vivo counting, routine workplace air sampling, personnel monitoring, and programmatic and job-specific As Low as Reasonably Achievable considerations

  13. Radiological control of a microPET/CT laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sarmento, Daniele M.; Sanches, Matias P.; Carneiro, Janete C.G.G., E-mail: dms.danica@gmail.com.br, E-mail: msanches@ipen.br, E-mail: janetgc@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This paper presents the radiological control of a research laboratory in order to satisfy national standards and international recommendations. The microPET/CT laboratory in IPEN uses an Albira system for research purposes in small animals. This study focuses mainly to carry out an initial radiological evaluation and the exposure situation related with the task. The assessment of workplace conditions and individual exposures constitutes as integral part of the operational monitoring programme. Initially, the radiometric survey in laboratory has been carried out using an ionization chamber Radcal 9010 (10 x 5 - 1800). In addition, nine monitoring points with potential exposure were selected, where thermoluminescent dosimeters, TLDs, of CaSO{sub 4}:Dy, were positioned. The occupationally exposed workers were monthly evaluated for external exposures using TL dosimeters, worn on the surface of the body. For internal exposure, the evaluated period was approximately one year starting on April 2014. The average effective dose of the occupationally exposed workers did not exceed 2.4 mSv in the year of 2014, which is equal to the recording level. The workplace, microPET/CT laboratory, is classified as supervised area and the monitoring results in the evaluated period, are within the dose limits established by national standard, as well as the values obtained in individual control. (author)

  14. NV/YMP radiological control manual, Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Gile, A.L. [comp.

    1996-11-01

    The Nevada Test Site (NTS) and the adjacent Yucca Mountain Project (YMP) are located in Nye County, Nevada. The NTS has been the primary location for testing nuclear explosives in the continental US since 1951. Current activities include operating low-level radioactive and mixed waste disposal facilities for US defense-generated waste, assembly/disassembly of special experiments, surface cleanup and site characterization of contaminated land areas, and non-nuclear test operations such as controlled spills of hazardous materials at the hazardous Materials (HAZMAT) Spill Center (HSC). Currently, the major potential for occupational radiation exposure is associated with the burial of low-level nuclear waste and the handling of radioactive sources. Planned future remediation of contaminated land areas may also result in radiological exposures. The NV/YMP Radiological Control Manual, Revision 2, represents DOE-accepted guidelines and best practices for implementing Nevada Test Site and Yucca Mountain Project Radiation Protection Programs in accordance with the requirements of Title 10 Code of Federal Regulations Part 835, Occupational Radiation Protection. These programs provide protection for approximately 3,000 employees and visitors annually and include coverage for the on-site activities for both personnel and the environment. The personnel protection effort includes a DOE Laboratory Accreditation Program accredited dosimetry and personnel bioassay programs including in-vivo counting, routine workplace air sampling, personnel monitoring, and programmatic and job-specific As Low as Reasonably Achievable considerations.

  15. Review of Atomic Energy Laws Related to Radiological Accidents and Methods of Improvement

    International Nuclear Information System (INIS)

    Chang, Gun Hyun; Kim, Sang Won; Yoo, Jeong; Ahn, Hyoung Jun; Park, Young Sik; Kim, Hong Suk; Kwon, Jeong Wan; Jang, Ki Won; Kim, Sok Chul

    2009-01-01

    Atomic energy-related laws in Korea have a two pronged management system for radiological accidents. To be specific, the Atomic Energy Act is applicable to all radiological accidents, i.e. accidents pertaining to nuclear facilities and radioactive materials while the Act for Physical Protection and Radiological Emergency ('APPRE') applies to accidents related to nuclear materials and large-scale nuclear facilities. The Atomic Energy Act contains three provisions directly related with radiological accidents (Articles 89, 98 and 102). Article 89 provides for the obligations of nuclear licensees or consigned transporters to institute safety measures and file a report to the head of the Ministry of Education, Science and Technology ('MEST') in the event of any radiological accident during transport or packing of radioactive materials, etc. Article 98 stipulates obligations of nuclear licensees to implement safety procedures and submit a report to the Minister of Education, Science and Technology concerning radiation hazards arising in the event a radiological accident occurs in connection with nuclear projects, as well as the Minister's requests to implement necessary measures. Article 102 explicitly provides for obligations to file a report to the Minister in the event of theft, loss, fire or other accidents involving radioactive materials, etc. in the possession of nuclear licensees. The APPRE classifies radiological accidents according to location and scale of the accidents. Based on location, accidents are divided into accidents inside or outside nuclear facilities. Accidents inside nuclear facilities refer to accidents that occur at nuclear reactors, nuclear fuel cycling facilities, radioactive waste storage, treatment and disposal facilities, facilities using nuclear materials and facilities related to radioisotopes of not lower than 18.5PBq (Subparagraph 2, Article 2 of the APPRE) while accidents outside nuclear facilities mean accidents that take place on

  16. Atomic Energy Control Regulations

    International Nuclear Information System (INIS)

    1992-01-01

    This is the consolidated text of the Atomic Energy Control Regulations of 17 March 1960, with amendments to 27 August 1992. The Regulations cover the licensing of nuclear facilities, radiation sources, including uranium mining, radiation protection questions, etc. (NEA)

  17. Trends in radiological and environmental protection at high energy accelerator laboratories

    International Nuclear Information System (INIS)

    Perry, D.R.; Shaw, K.B.; Stapleton, G.B.; Thomas, R.H.

    1991-03-01

    The serious study of high-energy particle accelerator radiological protection began in the early 1950s and has continued since then. This paper treats the subject in seven stages, and begins by briefly reviewing the work done until the 80s, which comprises the first five stages. These are, observation of high radiation levels, shielding studies, dosimetry, induced activity and the environmental effects. The sixth stage, control by legislation and regulation, is discussed in detail. Over the past twenty years there have been significant additions to radiological protection standards: from a scientifically based estimate of risk to a social desire to reduce exposure to levels determined only by the ''best practical means (BPM)'' or as it is currently understood in the United States of America ''best available technology (BAT)''. The implications of this trend are explored, and the success with which changing standards have been followed is studied with the aid of data derived from personnel doses. The last stage is the decommissioning or disposal of high energy accelerators. (author)

  18. United States Department of Energy radiological emergency response programme - a national capability

    International Nuclear Information System (INIS)

    Gordon-Hagerty, L.E.

    1993-01-01

    In order to respond to a radiological emergency, the United States Department of Energy (USDOE) maintains seven emergency response assets and capabilities in support of a radiological emergency of any proportion within the continental United States and abroad. The seven emergency response assets and capabilities include: Accident Response Group; Aerial Measuring Systems; Atmospheric Release Advisory Capability; Federal Radiological Monitoring and Assessment Center; Nuclear Emergency Search Team; Radiation Emergency Assistance Center/Training Site; and Radiological Assistance Program. Presently, USDOE maintains the most comprehensive national radiological emergency response assets in the United States, capable of dealing with any type of emergency involving nuclear materials. In all, the Department's assets are available to support any type of accident/incident involving radioactive materials in coordination with other United States Federal agencies, as well as state and local governments, as required. (author)

  19. Quality control of the interpretation monitors of digital radiological images

    International Nuclear Information System (INIS)

    Favero, Mariana S.; Goulart, Adriano Oliveira S.

    2016-01-01

    The performance monitors has great importance in image quality of digital radiographic systems. In environments without films, it became necessary to implement acceptance testing and quality control monitors used for interpretation of medical images. The monitors dedicated to radiodiagnostic should provide information that represent slight differences in x-ray attenuation or minor differences in some anatomical region of interest. This should also result in small differences in luminance of an image represented. Factors affecting the quality of medical imaging are contrast, noise, resolution, artifacts and distortions. Therefore, a monitor must have specific characteristics, making it possible for the observer to carry out an assessment that leads to better diagnosis. Based on the need to evaluate diagnostic monitors in various radiological applications, this paper presents a summary for implementation and standardization of tests that are recommended by the publication AAPM Report 03. (author)

  20. Radiological information systems: improvements in service, economy, and quality control?

    International Nuclear Information System (INIS)

    Gross-Fengels, W.; Weber, M.

    1997-01-01

    By means of complete service control and standardized accounting processes, radiological information systems clearly contribute to improved results. They provide the prerequisites for the establishment of expanded networks and allow comprisons with comparable institutions. The quality of patient care can be improved since, for example, the production time from referral to finished result becomes shorter. Direct access to patient and findings data from several positions is possible. Preliminary results can be viewed immediately. The patient's history is accessible to authorized users at all times. The exact reproducibility and assignment of services leads to more clarity. By means of the information available form RIS, rapid adaptive processes can be undertaken. The system assists the to fulfill the requirements of health regulations. The above-mentioned relationships demonstrate that the EDP systems are well accepted by physicians, medical assistants, and administrators and represent an indispensable aid for solving problems. (orig.) [de

  1. Quality Control in diagnostic radiology according to national regulations

    International Nuclear Information System (INIS)

    Domienik, J.; Chruscielewski, W.; Jankowski, J.

    2006-01-01

    The aim of the paper is to review the main aspects of quality control of radiological devices according to the current national regulations. Explanation of the physical principles of image formation by different test phantoms used to measure focal spot sizes is presented in appendix. The obligation for quality assurance (QA) for all X-ray systems which follows European standards was enforced in updated '' Atomic Law Act '' of 29 November 2000 . This document is the main regulatory act which establishes the basic safety standards for radiation protection in Poland. The main modifications introduced by this new Act concerned the issue of radiation protection of individuals undergoing medical examinations with the use of ionizing radiation which is regulated by EC Directive 97/43 Euratom. According to this Directive quality assurance programmes, including quality control measures need to be implemented by the holder of the radiological installation. Therefore, in the above Act the Minister of Health has been obligated to impose specific regulations describing the way of implementation of general principles laid down in the Directive. Some of these regulations, like those concerning QC tests and tolerances, have already been mentioned in the document titled '' On the conditions for safe application of ionizing radiation in medicine ''. For example, the QC program in radiography is being considered; the obligatory tests- acceptance, routine and annual- are discussed and specific procedures are being indicated. The main idea of the document '' On the conditions for safe application of ionizing radiation in medicine '' which concerns radiation protection of patients and staff against ionizing radiation used in medicine is to implement the surveillance of all X-ray systems in form of acceptance tests followed by internal tests (routine and annual) performed in accordance with European standards. (author)

  2. Quality control of diagnostic radiology to reduce absorbed dose of patients in Iran

    International Nuclear Information System (INIS)

    Aghahadi, Bahman.

    1996-01-01

    In order to reduce absorbed dose, to increase the image quality and to reduce the numbers of rejected films various quality control parameters were applied to X ray machines. These parameter are Kilo Volt peak, Milli Ampere, Exposure Time Focal Film Distance, Inherent Filters, Additional Filters Half Value Layer, Processor Condition, Cassettes. To evaluate and to apply these parameters in diagnostic radiological centers, ten hospitals were selected and a total number of 12 X ray machines were kept under quality control program. Considering different kinds of diagnostic radiology examination and to compare the dose before and after implementation of a quality control program, two kinds of examinations include in chest and abdomen examinations were considered. For each X ray machine, ten patients and for all selected centers, 120 patients were selected for chest examination and 120 patients for abdomen examinations; before and after implementation of quality control program, a total of 480 patients were selected randomly to be controlled. Base on different examinations carried out, it was concluded that both exposure conditions and general situations in radiological centers were not acceptable. The dosimetry results show that the average ski dose for chest and abdomen examinations were 0.28 m Gy and 4.23 Gy respectively. Before implementation of quality control step to reduce the surface skin dose, quality control parameters were applied and the exposure conditions were imposed. On average the absorbed doses for chest and abdomen examination were decreased to 79% and 61% respectively after the implementation of the program. From dose reduction point of view, the results of a part of this project which made by co-operation of International Atomic Energy Agency showed that Iran acquired the first grade for chest examination and second grade for abdomen examination. Base on the results obtained, the number of patients under chest and abdomen examination were 4041588 and

  3. Energy control and sustainable development

    International Nuclear Information System (INIS)

    2002-01-01

    The contributions are dealing with the different aspects of energy control: key figures of the world consumption, evolution perspectives (energy control and energy demand in middle- and long-term world scenarios, global challenges, European perspectives, energy control in public decision in France, the new French energy accounting), regional differences (energy control in the United States, Russia, China, India, Brazil, West Africa, Mediterranean Sea), energy control and society (electricity privatisation in Salvador, regulatory approach or voluntary agreements for domestic appliances, comparison of energy control and renewable energies in France, complex accounting for energy demand control in a consumption society)

  4. Offsite dose calculation manual guidance: Standard radiological effluent controls for boiling water reactors

    International Nuclear Information System (INIS)

    Meinke, W.W.; Essig, T.H.

    1991-04-01

    This report contains guidance which may be voluntarily used by licensees who choose to implement the provision of Generic Letter 89-- 01, which allows Radiological Effluent Technical Specifications (RETS) to be removed from the main body of the Technical Specifications and placed in the Offsite Dose Calculation Manual (ODCM). Guidance is provided for Standard Effluent Controls definitions, Controls for effluent monitoring instrumentation, Controls for effluent releases, Controls for radiological environmental monitoring, and the basis for Controls. Guidance on the formulation of RETS has been available in draft form for a number of years; the current effort simply recasts those RETS into Standard Radiological Effluent Controls for application to the ODCM. 11 tabs

  5. Natural radiation - a perspective to radiological risk factors of nuclear energy production

    DEFF Research Database (Denmark)

    Mustonen, R.; Christensen, T.; Stranden, E.

    1992-01-01

    Radiation doses from natural radiation and from man-made modifications on natural radiation, and different natural radiological environments in the Nordic countries are summarized and used as a perspective for the radiological consequences of nuclear energy production. The significance of different...... radiation sources can be judged against the total collective effective dose equivalent from natural radiation in the Nordic countries, 92 000 manSv per year. The collective dose from nuclear energy production during normal operation is estimated to 20 manSv per year and from non-nuclear energy production...... to 80 manSv per year. The increase in collective dose due to the conservation of heating energy in Nordic dwellings is estimated to 23 000 manSv per year, from 1973 to 1984. An indirect radiological danger index is defined in order to be able to compare the significance of estimated future releases...

  6. Proposal of inspection methodology for environment radiological control; Proposta de metodologia de inspecao para controle radiologico ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Nadia Soido Falcao

    2005-07-01

    The Radiation Protection and Dosimetry Institute (IRD) of the Brazilian Nuclear Energy Commission (CNEN) is in charge of verifying that the self-monitoring operator is effective to control the radiological quality of environmental around the nuclear facilities and carried out in accordance with the regulatory requirements. While a long time, the verification of compliance was kept by the conduction of large scale monitoring programs around all the authorized installations. The IRD decided to reformulate its performance behavior, starting another kind of control program, due to the number increase of nuclear installations and the diversity of activities conducted by the operators. This program, so-called Monitoring Control Program (PCM) is a regulatory activity developed by the Environmental Impact Assessment Service (SEAIA) of IRD and has the aim of check the effectiveness of authorized self-control. Actually the regulatory control of environmental radiological integrity around the authorized nuclear installation essentially depends on the effectiveness of regulatory inspections fulfilled by the SEAIA/IRD. Due to the implementation of modern practices of management in the IRD, specially the quality management system on regulatory inspection activities, emerged the need of unify these actions. It was also necessary to establish standard procedures required for inspection conduction. This work proposes one methodology for the inspections of environmental radiological control suitable to assure the compliance and effectiveness of environmental and effluent monitoring programs conducted by the operator, through the systematic verification of compliance and data quality assessment. The proposed methodology seeks to attend the appeals for high control standards of environment protection and public health. Here, we presented as products of this work: The inspection handbook and checklists for inspections; one framework for sampling, handling, recording and reporting of

  7. Development of radiological profiles for U.S. Department of Energy low-level mixed wastes

    International Nuclear Information System (INIS)

    Wilkins, B.D.; Meshkov, N.K.; Dolak, D.A.; Wang, Y.Y.

    1995-01-01

    Radiological profiles have been developed by Argonne National Laboratory for low-level mixed wastes (LLMWs) that are under the management of the US Department of Energy (DOE). These profiles have been used in the Office of Environmental Management Programmatic Environmental Impact Statement (EM PEIS) to support the analysis of environmental and health risks associated with the various waste management strategies. The radiological characterization of DOE LLMWs is generally inadequate and has made it difficult to develop a site- and waste-stream-dependent radiological profile for LLMWs. On the basis of the operational history of the DOE sites, a simple model was developed to generate site-dependent and waste-stream-independent radiological profiles for LLMWs. This paper briefly discusses the assumptions used in this model and the uncertainties in the results

  8. Moving beyond quality control in diagnostic radiology and the role of the clinically qualified medical physicist.

    Science.gov (United States)

    Delis, H; Christaki, K; Healy, B; Loreti, G; Poli, G L; Toroi, P; Meghzifene, A

    2017-09-01

    Quality control (QC), according to ISO definitions, represents the most basic level of quality. It is considered to be the snapshot of the performance or the characteristics of a product or service, in order to verify that it complies with the requirements. Although it is usually believed that "the role of medical physicists in Diagnostic Radiology is QC", this, not only limits the contribution of medical physicists, but is also no longer adequate to meet the needs of Diagnostic Radiology in terms of Quality. In order to assure quality practices more organized activities and efforts are required in the modern era of diagnostic radiology. The complete system of QC is just one element of a comprehensive quality assurance (QA) program that aims at ensuring that the requirements of quality of a product or service will consistently be fulfilled. A comprehensive Quality system, starts even before the procurement of any equipment, as the need analysis and the development of specifications are important components under the QA framework. Further expanding this framework of QA, a comprehensive Quality Management System can provide additional benefits to a Diagnostic Radiology service. Harmonized policies and procedures and elements such as mission statement or job descriptions can provide clarity and consistency in the services provided, enhancing the outcome and representing a solid platform for quality improvement. The International Atomic Energy Agency (IAEA) promotes this comprehensive quality approach in diagnostic imaging and especially supports the field of comprehensive clinical audits as a tool for quality improvement. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Quality control in diagnostic radiology: software (Visual Basic 6) and database applications

    International Nuclear Information System (INIS)

    Md Saion Salikin; Muhammad Farid Abdul Khalid

    2002-01-01

    Quality Assurance programme in diagnostic Radiology is being implemented by the Ministry of Health (MoH) in Malaysia. Under this program the performance of an x-ray machine used for diagnostic purpose is tested by using the approved procedure which is commonly known as Quality Control in diagnostic radiology. The quality control or performance tests are carried out b a class H licence holder issued the Atomic Energy Licensing Act 1984. There are a few computer applications (software) that are available in the market which can be used for this purpose. A computer application (software) using Visual Basics 6 and Microsoft Access, is being developed to expedite data handling, analysis and storage as well as report writing of the quality control tests. In this paper important features of the software for quality control tests are explained in brief. A simple database is being established for this purpose which is linked to the software. Problems encountered in the preparation of database are discussed in this paper. A few examples of practical usage of the software and database applications are presented in brief. (Author)

  10. The Atomic Energy Control Board

    International Nuclear Information System (INIS)

    Doern, G.B.

    1976-01-01

    This study describes and assesses the regulatory and administrative processes and procedures of the Atomic Energy Control Board, the AECB. The Atomic Energy Control Act authorized the AECB to control atomic energy materials and equipment in the national interest and to participate in measures for the international control of atomic energy. The AECB is authorized to make regulations to control atomic energy materials and equipment and to make grants in support of atomic energy research. (author)

  11. Radiological Information Management System - an effective tool for radiological information dissemination and dose control

    International Nuclear Information System (INIS)

    Sharma, Ravikant; Singh, Mintoo; Abhishek, Neel; Yadav, Umed

    2012-01-01

    Information is a key element for success of an organization, and timely information is a guarantee to success. To meet this essential requirement, Health Physics Unit at RAPS-5 and 6 has conceived, designed and implemented a comprehensive integrated network based system, named Radiological Information Management System (RIMS). The complete system is designed on the principle of FOUR ONE's i.e. ONE data entry by ONE individual at ONE time using ONE system/client

  12. Method and apparatus for laser-controlled proton beam radiology

    Science.gov (United States)

    Johnstone, Carol J.

    1998-01-01

    A proton beam radiology system provides cancer treatment and proton radiography. The system includes an accelerator for producing an H.sup.- beam and a laser source for generating a laser beam. A photodetachment module is located proximate the periphery of the accelerator. The photodetachment module combines the H.sup.- beam and laser beam to produce a neutral beam therefrom within a subsection of the H.sup.- beam. The photodetachment module emits the neutral beam along a trajectory defined by the laser beam. The photodetachment module includes a stripping foil which forms a proton beam from the neutral beam. The proton beam is delivered to a conveyance segment which transports the proton beam to a patient treatment station. The photodetachment module further includes a laser scanner which moves the laser beam along a path transverse to the cross-section of the H.sup.- beam in order to form the neutral beam in subsections of the H.sup.- beam. As the scanning laser moves across the H.sup.- beam, it similarly varies the trajectory of the proton beam emitted from the photodetachment module and in turn varies the target location of the proton beam upon the patient. Intensity modulation of the proton beam can also be achieved by controlling the output of the laser.

  13. Automatic radiological control of the working room air at Valduc

    International Nuclear Information System (INIS)

    Herve, J.Y.; Camus, L.; Leroux, J.C.

    1991-01-01

    The facilities of the Centre d'etudes de Valduc, require air control in the different rooms where a radiological hazard exists. To this purpose, every day, the radiation protection technicians put 230 filters on the sampling heads in the working places proximity. To measure any radioactivity retained by the filters, the Valduc Radiation protection service uses an automated system, which identifies the filter origin, carries out the measurements and produces the results. Filters are identified by bar code labels, which are red by an optical reader located in each of the two measurement lines. These are Nu-16 (Numelec Ins.) type low α-and β-activity counting sets, equipped with proportional mode circulation counters. An IBM-PC type microcomputer is used for the whole assembly monitoring and the data centralization. Results can be edited in different forms: daily, monthly, trimestrial or annual results. The system operating mode is satisfying, and has allowed to clear an one-man equivalent work-load [fr

  14. An experimental investigation on reduced radiological penumbra for intermediate energy x-rays: Implications for small field radiosurgery

    Science.gov (United States)

    Keller, Brian Michael

    Current day external beam radiation therapy typically uses x-ray energies in the megavoltage (6--18 MV) or in the superficial/orthovoltage (80--350 kVp) energy ranges. It has been found that intermediate energy x-rays (those greater than orthovoltage but sub-megavoltage) may offer an advantage in the field of high precision radiation therapy such as in radiosurgery. This advantage is a reduction in the radiological penumbra associated with small (less than about 3 cm) radiation dose fields. A consequence of reduced radiological penumbra is a more homogenous, conformal dose distribution in the patient with dose escalation and organ sparing made more feasible. The objectives of this thesis were as follows: to produce and to characterize an intermediate energy x-ray beam, to establish a method of accurate penumbra measurement at the micron level for millimeter size fields, to measure the radiological penumbra of single small intermediate energy x-ray fields, and to show the clinical consequences of a multiple beam irradiation in a stereotactic head phantom. A maximum photon energy of 1.2 +/- 0.1 MeV was determined for the intermediate energy x-ray spectrum at the expense of a low dose rate. A digital microscope with a computer controlled translation stage was investigated for its ability to resolve steep dose gradients in Gafchromic EBT film for field sizes as small as 1 mm and for photon energies as low as 100 kVp. The microscope-film system resolved gradients to within about 30 mum, limited by the inherent spatial resolution of the film, the noise of the system, and the uncertainties of measurement. Penumbra widths were compared for 1.2 MV versus 6 MV for identical irradiation conditions. In some instances, there was a five-fold reduction in the radiological penumbra of single 1.2 MV x-ray beams. A multiple beam arc irradiation demonstrated that the advantages seen with single beams carry over to multiple beams. The benefits of reduced radiological penumbra for

  15. Radiological safety in extraction of rare earths in India: regulatory control

    International Nuclear Information System (INIS)

    Sinha, S.; Bhattacharya, R.

    2011-01-01

    The term 'rare earths' refers to a group of f-block elements in the periodic table including those with atomic numbers 57 (Lanthanum) to 71 (Lutetium), as well as the transition metals Yttrium (39) and Scandium (21). Economically extractable concentrations of rare earths are found in minerals such as monazite, bastnaesite, cerites, xenotime etc. Of these, monazite forms the main source for rare earths in India, which along with other heavy minerals is found abundantly in the coastal beach sands. However, in addition to rare earths, monazite also contains 0.35% U 3 O 8 and 8-9% ThO 2 . Hence, extraction of rare earths involves chemical separation of the rare earths from thorium and uranium which are radioactive. The processing and extraction of rare earths from monazite therefore invariably results in occupational radiation exposure to the workers involved in these operations. In addition, in the process of removal of radioactivity from rare earths, radioactive solid waste gets generated which has 2 2 8Ra concentration in the range 2000-5000 Bq/g. Unregulated disposal of such high active waste would not only result in contamination of the soil but the radionuclides would eventually enter the food chain and lead to internal exposure of the general public. Therefore such facilities involved in recovery of rare earths from monazite attract the provisions of radiological safety regulations. Atomic Energy Regulatory Board of India has been enforcing the provisions of The Atomic Energy (Radiation Protection) Rules, 2004 and The Atomic Energy (Safe Disposal of Radioactive Waste) Rules, 1987 in these facilities. This paper shall discuss the associated radiological hazard involved in recovery of rare earths from monazite. It shall also highlight the regulatory requirements for controlling the occupational exposure of workers during design stage such as requirements on lay out of the building, ventilation, containment of radioactivity, etc and also the during operational

  16. Offsite dose calculation manual guidance: Standard radiological effluent controls for pressurized water reactors

    International Nuclear Information System (INIS)

    Meinke, W.W.; Essig, T.H.

    1991-04-01

    This report contains guidance which may be voluntarily used by licensees who choose to implement the provision of Generic Letter 89-01, which allows Radiological Effect Technical Specifications (RETS) to be removed from the main body of the Technical Specifications and placed in the Offsite Dose Calculation Manual (ODCM). Guidance is provided for Standard Effluent Controls definitions, Controls for effluent monitoring instrumentation, Controls for effluent releases, Controls for radiological environmental monitoring, and the basis for Controls. Guidance on the formulation of RETS has been available in draft from (NUREG-0471 and -0473) for a number of years; the current effort simply recasts those RETS into Standard Radiological Effluent Controls for application to the ODCM. Also included for completeness are: (1) radiological environmental monitoring program guidance previously which had been available as a Branch Technical Position (Rev. 1, November 1979); (2) existing ODCM guidance; and (3) a reproduction of generic Letter 89-01

  17. Radiological control guide for decommissioning of the TRIGA mark-2, 3

    International Nuclear Information System (INIS)

    Lee, Bong Jae

    2000-08-01

    The purpose of radiological control for TRIGA mark-2, 3 research reactors and facilities at the KAERI Seoul site, which are to be decommissioned, is in minimizing the radiation exposure for workers and in preventing the release of the radioactive materials to the environment. In order to accomplish these goal, the radiological control guide will be prepared during the decommissioning activities. Therefore, it is expected that this technical report can be used in preparing radiological control guide for safety decommissioning of the TRIGA mark-2, 3

  18. Quality control in medical radiology using T.L.D

    International Nuclear Information System (INIS)

    Rolemberg Silva, F.A.; Nascimento Souza, D. do

    2006-01-01

    In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO 4 :Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between 8.0 μGy and 0.35 μGy. The T.L.D. have revealed useful for the measures if the response to the dose is previously known for each set of beam parameters used for the irradiations. Otherwise, the tests with the dosimeters can serve to evaluate the beams conditions and their reproducibility. The evaluation results of coherence between the luminous fields and the irradiation fields demonstrated that the difference between the radiation and the luminous fields did not exceed 2% of the distance between the focal point and the film. We found satisfactory values for half-value layer. (author)

  19. Review of Atomic Energy Laws Related to Radiological Accidents and Methods of Improvement

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Gun Hyun; Kim, Sang Won; Yoo, Jeong; Ahn, Hyoung Jun; Park, Young Sik; Kim, Hong Suk; Kwon, Jeong Wan; Jang, Ki Won; Kim, Sok Chul [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2009-05-15

    Atomic energy-related laws in Korea have a two pronged management system for radiological accidents. To be specific, the Atomic Energy Act is applicable to all radiological accidents, i.e. accidents pertaining to nuclear facilities and radioactive materials while the Act for Physical Protection and Radiological Emergency ('APPRE') applies to accidents related to nuclear materials and large-scale nuclear facilities. The Atomic Energy Act contains three provisions directly related with radiological accidents (Articles 89, 98 and 102). Article 89 provides for the obligations of nuclear licensees or consigned transporters to institute safety measures and file a report to the head of the Ministry of Education, Science and Technology ('MEST') in the event of any radiological accident during transport or packing of radioactive materials, etc. Article 98 stipulates obligations of nuclear licensees to implement safety procedures and submit a report to the Minister of Education, Science and Technology concerning radiation hazards arising in the event a radiological accident occurs in connection with nuclear projects, as well as the Minister's requests to implement necessary measures. Article 102 explicitly provides for obligations to file a report to the Minister in the event of theft, loss, fire or other accidents involving radioactive materials, etc. in the possession of nuclear licensees. The APPRE classifies radiological accidents according to location and scale of the accidents. Based on location, accidents are divided into accidents inside or outside nuclear facilities. Accidents inside nuclear facilities refer to accidents that occur at nuclear reactors, nuclear fuel cycling facilities, radioactive waste storage, treatment and disposal facilities, facilities using nuclear materials and facilities related to radioisotopes of not lower than 18.5PBq (Subparagraph 2, Article 2 of the APPRE) while accidents outside nuclear facilities mean accidents

  20. Oceanographic model and radiological basis for control of radionuclide releases

    International Nuclear Information System (INIS)

    Hagen, A.A.

    1984-01-01

    Since it first prepared the provisional Definition of high-level radioactive waste unsuitable for dumping at sea and Recommendations for those radioactive wastes dumped under special permit in 1974, the IAEA has kept the Definition and Recommendations under continuing review. The oceanographic basis for the definition is being re-evaluated, based on a 1983 Report from the IMO/FAO/UNESCO/WMO/WHO/IAEA/UN/UNEP Joint Group of Experts on the Scientific Aspects of Marine Pollution (GESAMP), and the radiological basis is being updated, based on a Report from an IAEA Advisory Group Meeting held in 1982. The differences in the current radiological and oceanographic bases and the updating of both the GESAMP Report on modelling and the review of the radiological basis are delineated. In addition, a discussion of the future course of the Agency's activities in this area is given. (author)

  1. Best Available Technology (BAT) guidance for radiological liquid effluents at US Department of Energy Facilities

    International Nuclear Information System (INIS)

    Wallo, A. III; Peterson, H.T. Jr.; Ikenberry, T.A.; Baker, R.E.

    1993-01-01

    The US Department of Energy (DOE), in DOE Order 5400.5 (1990), directs operators of DOE facilities to apply the Best Available Technology (BAT) to control radiological liquid effluents from these facilities when specific conditions are present. DOE has published interim guidance to assist facility operators in knowing when a BAT analysis is needed and how such an analysis should be performed and documented. The purpose of the guidance is to provide a uniform basis in determining BAT throughout DOE and to assist in evaluating BAT determinations during programmatic audits. The BAT analysis process involves characterizing the effluent source; identifying and selecting candidate control technologies; evaluating the potential environmental, operational, resource, and economic impacts of the control technologies; developing an evaluation matrix for comparing the technologies; selecting the BAT; and documenting the evaluation process. The BAT analysis process provides a basis for consistent evaluation of liquid effluent releases, yet allows an individual site or facility the flexibility to address site-specific issues or concerns in the most appropriate manner

  2. Radiological Impacts and Regulation of Rare Earth Elements in Non-Nuclear Energy Production

    Directory of Open Access Journals (Sweden)

    Timothy Ault

    2015-03-01

    Full Text Available Energy industries account for a significant portion of total rare earth usage, both in the US and worldwide. Rare earth minerals are frequently collocated with naturally occurring radioactive material, imparting an occupational radiological dose during recovery. This paper explores the extent to which rare earths are used by various non-nuclear energy industries and estimates the radiological dose which can be attributed to these industries on absolute and normalized scales. It was determined that typical rare earth mining results in an occupational collective dose of approximately 0.0061 person-mSv/t rare earth elements, amounting to a total of 330 person-mSv/year across all non-nuclear energy industries (about 60% of the annual collective dose from one pressurized water reactor operated in the US, although for rare earth mining the impact is spread out over many more workers. About half of the collective dose from non-nuclear energy production results from use of fuel cracking catalysts for oil refining, although given the extent of the oil industry, it is a small dose when normalized to the energy equivalent of the oil that is used annually. Another factor in energy industries’ reliance on rare earths is the complicated state of the regulation of naturally occurring radiological materials; correspondingly, this paper also explores regulatory and management implications.

  3. Application of classical versus bayesian statistical control charts to on-line radiological monitoring

    International Nuclear Information System (INIS)

    DeVol, T.A.; Gohres, A.A.; Williams, C.L.

    2009-01-01

    False positive and false negative incidence rates of radiological monitoring data from classical and Bayesian statistical process control chart techniques are compared. The on-line monitoring for illicit radioactive material with no false positives or false negatives is the goal of homeland security monitoring, but is unrealistic. However, statistical fluctuations in the detector signal, short detection times, large source to detector distances, and shielding effects make distinguishing between a radiation source and natural background particularly difficult. Experimental time series data were collected using a 1' x 1' LaCl 3 (Ce) based scintillation detector (Scionix, Orlando, FL) under various simulated conditions. Experimental parameters include radionuclide (gamma-ray) energy, activity, density thickness (source to detector distance and shielding), time, and temperature. All statistical algorithms were developed using MATLAB TM . The Shewhart (3-σ) control chart and the cumulative sum (CUSUM) control chart are the classical procedures adopted, while the Bayesian technique is the Shiryayev-Roberts (S-R) control chart. The Shiryayev-Roberts method was the best method for controlling the number of false positive detects, followed by the CUSUM method. However, The Shiryayev-Roberts method, used without modification, resulted in one of the highest false negative incidence rates independent of the signal strength. Modification of The Shiryayev-Roberts statistical analysis method reduced the number of false negatives, but resulted in an increase in the false positive incidence rate. (author)

  4. Radiological and Medical Sciences Research Institute, Ghana Atomic Energy Commission: Annual Report 2014

    International Nuclear Information System (INIS)

    2014-01-01

    The Radiological and Medical Sciences Research Institute was established in 2009, as the forth research institute of the Ghana Atomic Energy Commission. This Annual Report provides an overview of the major activities of the Institutes in the year 2014. Major items covered in the report include: Strategic objectives; Collaborations; Personnel and Organisational Structure; Facilities and Technical Services; Summary of Research and Development Projects; Human Resource Development; Publications and Technical Reports.

  5. Nuclear and radiological safety 1980-1994. International Atomic Energy Agency Publications

    International Nuclear Information System (INIS)

    1995-06-01

    This catalogue lists all sales publications of the International Atomic Energy Agency dealing with Nuclear and Radiological Safety issued during the period 1980-1994. The following aspects are covered: Uranium mining and milling, Fuel fabrication and storage, Nuclear power plants, Research reactors, Radiation sources and accelerators, Transport of radioactive materials, Waste repositories, Radiation protection, Accident response, Radioactive waste management, Safety analysis, Quality management, Legal and governmental aspects

  6. Primary contention 12RU1 radiological control; Contencion primaria 12RU1 control radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Padilla C, I. [CFE, Central Laguna Verde, Subgerencia General de Operacion, Proteccion Radiologica, Veracruz (Mexico)]. e-mail: ipadilla@cfe.gob.mx

    2007-07-01

    In the primary contention of the Laguna Verde central reactors those are located the main components and control and safety systems related directly with the reactor vessel. Space, accesses, location, maneuvers, armor-plating, movements of components and radiological conditions require of a constant attention to maintain the control of the activities during a fuel reload period. Knowledge, analysis, strategies and attention to the detail in the preparation stages and execution of the fuel reload are fundamental to sum up the objectives. The reload stop 12 of the Unit 1, it required a specific attention in the radiation source due to the addition of noble metals and hydrogen to the vessel internals that generated an increment in the soluble elements of Cobalt and that it was reflected in the radiation fields in the primary contention. Movement of armor-plating of the structures of the biological armor-plating demand to establish new strategies in the control of activities for the next fuel reloads. The analysis and control of the relief valves safety of the reactor vessel, of the exchange of the activation mechanisms of the control bars, as well as of the isolation valves of main vapor and of flow control valves of the reactor recirculation system, its required of a particular attention due to their particular radiological environment, in a brief time space. The importance of this work is located in the detail of critical activities to fulfill the established goals, with successes that can be optimized, and improvement areas that require of investigation and analysis for the implementation of new technologies tend toward to the dose optimization. The reload stop 12 of the unit 1 conclude with 2.43 Sv-person in a period of 27.5 days. (Author)

  7. Idaho National Engineering Laboratory Radiological Control performance indicator report: First quarter, calendar year 1995

    International Nuclear Information System (INIS)

    Aitken, S.B.

    1995-07-01

    The INEL Radiological Control Performance Indicator Report is provided quarterly, inaccordance with Article 133 of the INEL Radiological Control Manual. Indicators are used as a measure of performance of the Radiological Control Program and as a motivation for improvement, not as a goal in themselves. These indicators should be used by management to assist in focusing priorities and attention and adherence to As-Low-As-Reasonably-Achievable (ALARA) practices. The ALARA Committees establish ALARA goals for the INEL based on forecasts and goals provided by each facility organizational manager or supervisor.Performance goals are realistic and measurable. Stringent goals are set at least annually to reflect expected workloads and improvement of radiological performance. Goals higher than previous goals may occasionally be set due to changes in work scope or mission. The INEL Radiological Control Performance Indicators consist of: Collective dose in person-rem; average worker dose, maximum dose to a worker, and maximum neutron dose to a worker;the number of skin and clothing contaminations, including the number of contaminated wounds and facial contaminations; the number of radioactive material intakes; the area of Contamination, High Contamination, and Airborne Radioactivity Areas in square feet; and airborne radioactivity events and spills

  8. Development of Tandem ionization chambers for use in quality control programs in radiotherapy and diagnostic radiology

    International Nuclear Information System (INIS)

    Costa, Alessandro Martins da

    2003-01-01

    A quality control program of X-ray equipment used in diagnostic radiology and radiotherapy requires the check of the beam qualities constancy in terms of the half-value layers. In this work, two special double-faced parallel-plate ionization chambers were developed with inner electrodes of different materials, in tandem system. The different energy response of the two faces of each chamber allowed the development of tandem systems useful for the check of beam qualities constancy. The main application of these ionization chambers will be in quality control programs of diagnostic and therapeutic X-ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the tandem chambers may also be utilized for measurements of air kerma values (and air kerma rates) in kilo voltage X-radiation fields used for diagnostic and therapeutic procedures. The chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams in accordance to international recommendations. They presented a very good level of performance. In this developed system no absorbers or special set-ups are necessary. A methodology of use of the chambers in the quality control of diagnostic and therapeutic X-ray systems was established, with the elaboration of the respective procedures. (author)

  9. Energy control policy

    International Nuclear Information System (INIS)

    Moisan, F.; Bosseboeuf, D.

    1995-01-01

    The report 'energy efficiency policies' shows the evolution of energy efficiency for different countries since the first petroleum crisis. The countries concerned by this study are European countries, North America ones, Japan, Eastern Asia countries and some out of OECD such Brazil, Chile, Poland. The results are presented in a global way and then by industry sectors, transports and tertiary and residential sectors. 8 tabs

  10. Controlling energy demand. What history?

    International Nuclear Information System (INIS)

    Beers, Marloes; Bonhomme, Noel; Bouvier, Yves; Pautard, Eric; Fevrier, Patrick; Lanthier, Pierre; Goyens, Valerie; Desama, Claude; Beltran, Alain

    2012-01-01

    this special dossier of the historical annals of electricity collection takes stock of the post 1970's history of energy demand control in industrialized countries: Abatement of energy dependence, the European Communities program of rational use of energy in the 1970's (Marloes Beers); The G7 and the energy cost: the limits of dialogue between industrialized countries - 1975-1985 (Noel Bonhomme); Saving more to consume more. The ambiguity of EDF's communication during the 'energy saving' era (Yves Bouvier); From rationing to energy saving certificates, 4 decades of electricity demand control in France and in the UK (eric Pautard); The French agency of environment and energy mastery (ADEME): between energy control and sustainable development (Patrick Fevrier); Hydro-Quebec and efficiency in household energy consumption, from 1990 to the present day (Pierre Lanthier); Control of energy consumption since the 1970's, the policy of rational use of energy in Walloon region - Belgium (Valerie Goyens); Electricity distribution in the new energy paradigm (Claude Desama); Conclusion (Alain Beltran)

  11. A comparative study of quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Kharita, M. H.; Khedr, M.S.; Wannus, K.M.

    2008-01-01

    The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period from 1999 to 2005 (41 hospitals and 95 X-ray machines were considered). Most of the X-ray machines studied were within the acceptable performance, but few machines needed recalibration for some parameters. Considerable improvement of about 50% was reported in the second period. This improvement could be attributed to the establishment of an effective National Regulatory Authority in Syria in 1998 that introduced and gradually enforced the quality assurance requirement for X-ray equipment as part of the licensing process and to the relatively newer X-ray machines covered in the second period. The Author 2008. Published by Oxford Univ. Press. All rights reserved. (authors)

  12. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J; Keller, Brian M; Presutti, Joseph; Sharpe, Michael

    2006-01-01

    Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle 3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 μm are generated for field size below 2 x 2 cm 2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle 3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam

  13. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery

    Science.gov (United States)

    O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J.; Keller, Brian M.; Presutti, Joseph; Sharpe, Michael

    2006-05-01

    Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 µm are generated for field size below 2 × 2 cm2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam.

  14. Present state and problems of radiological protection monitoring for high energy electron accelerator facilities in SPring-8

    International Nuclear Information System (INIS)

    Miyamoto, Yukihiro; Harada, Yasunori; Ueda, Hisao

    1998-09-01

    The present state and problems of the radiological protection monitoring for the high-energy electron accelerator are summarized. In the radiological protection monitoring for SPring-8, a third generation synchrotron radiation facility, there are many problems specific to the high-energy electron accelerator. This report describes the monitoring technique of pulsed radiation, high-energy radiation and low-energy radiation, and their problems. The management of induced radioactivity and the effects of electro-magnetic noise to monitoring instruments are also discussed. (author)

  15. Assessment of the radiological control at the IPEN radioisotope production facility

    International Nuclear Information System (INIS)

    Carneiro, Janete C.G.G.; Sanches, Matias P.; Rodrigues, Demerval L.; Campos, Daniela; Nogueira, Paulo R.; Damato, Sandra R.; Pecequilo, Brigitte R.

    2014-01-01

    The main objective of this work is to evaluate the 2013 annual radiological control results in the radiopharmaceuticals areas of the Instituto de Pesquisas Energeticas e Nucleares, IPEN/SP, and the environmental radiological impact, resulting from the practices there performed. The current evaluation was performed through the analysis of the results obtained from occupational and environmental monitoring with air samplers and TL dosimeters. All monitoring results were compared with the limits established by national standards. The radionuclides detected by air sampling (in charcoal and paper filters) at the workplace during radioisotope production were 131 I, 99m Tc and 99 Mo, with activities concentrations values below the annual limits values. For the radioactive gaseous releases (Bq/m 3 ), the activities concentrations also remained below the maximum permissible values, excepting to 125 I release due to an unusual event occurred in a researcher laboratory, but the radiological impact to environmental was no significant. The occupational monitoring assessment was confirmed by the Environmental Radiological Monitoring Program results with air samplers and TL dosimeters. The mean annual background radiation at IPEN in 2013, according to the Environmental Radiological Monitoring Program results was 1.06 mSv. y -1 , below the ICRP 103 recommended limit of 20 mSv.y -1 for workers. (author)

  16. The present condition of the radiation safety control education in training schools for radiological technologists

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Saito, Kyoko; Hirai, Shoko; Igarashi, Hiroshi; Negishi, Tooru; Hirano, Kunihiro; Kawaharada, Yasuhiro

    2010-01-01

    We made a detailed study on the course of study in radiation safety control prescribed on March 28, 2003. Questionnaires were sent to 39 training schools for radiological technology, to which 66.7% replied (26/39). Subjects on radiation safety control must include knowledge and technology in both radiation control and medical safety. The contents for instruction of radiation control were in accordance with those given in the traditional program; however, some discrepancies were found in the contents of medical safety. As medical safety, emphasized by the revised Medical Service Law, is regarded as very important by many hospitals, safety control education that include medical ethics should be required as part of the curriculum in the training schools for radiological technologists. (author)

  17. Changes in radiological protection and quality control in Spanish dental installations: 1996-2003.

    Science.gov (United States)

    Alcaraz-Baños, Miguel; Parra-Pérez, María del Carmen; Armero-Barranco, David; Velasco-Hidalgo, Francisco; Velasco-Hidalgo, Esteban

    2009-10-01

    The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check. To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients. A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period. According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied. there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection.

  18. Motion sensing energy controller

    International Nuclear Information System (INIS)

    Saphir, M.E.; Reed, M.A.

    1984-01-01

    A moving object sensing processor responsive to slowly varying motions of a human being or other moving object in a zone of interest employs high frequency pulse modulated non-visible radiation generated by a radiation generating source, such as an LED, and detected by a detector sensitive to radiation of a preselected wavelength which generates electrical signals representative of the reflected radiation received from the zone of interest. The detectorsignals are processed to normalize the base level and remove variations due to background level changes, and slowly varying changes in the signals are detected by a bi-polar threshold detector. The control signals generated by the threshold detector in response to slowly varying motion are used to control the application of power to a utilization device, such as a set of fluoroescent lights in a room, the power being applied in response to detection of such motion and being automatically terminated in the absence of such motion after a predetermined time period established by a settable incrementable counter

  19. New U.K. safety legislation and its effects on the control of radiological hazards

    International Nuclear Information System (INIS)

    Bell, B.H.J.; Luxon, S.G.

    1977-01-01

    This paper explains the objectives of the Health and Safety at Work etc Act 1974 and refers in particular to its effects on the control of hazards at nuclear installations and, more widely, on the control of radiological hazards generally. It deals also with the changes resulting from the setting up of the Health and Safety Commission and its Executive under the new Act, and the effects of these changes on the work of the Nuclear Installations Inspectorate. (auth.) [fr

  20. Current State Park General Radiology in the region of Murcia. 18 years of quality control

    International Nuclear Information System (INIS)

    Vera Sanchez, J. A.; Buades Forner, M. J.; Tobarra Gonzalez, B. M.

    2011-01-01

    This paper examines the latest campaign for quality control of technical parameters of equipment carried out by l Radiological Protection Service of the Hospital Universitario Virgen de la Arrixaca, and compare the present results with those presented by this same service Congress of the Spanish Society of Medical Physics in 1993. [1], corresponding to the first quality control campaign conducted in 1992. (Author) 2 refs.

  1. Environmental Health Impacts of Nuclear Fuel Cycle With Emphasis to Monitoring and Radiological Safety Control System

    International Nuclear Information System (INIS)

    Gad Allah, A.A.; El- Shanshory, A.I.

    2010-01-01

    facilities, as well as their health impacts instruments and monitors systems for radiological control have been reviewed and evaluated

  2. Perception of quality control by personnel in diagnostic radiology ...

    African Journals Online (AJOL)

    This situation may be due to the perceived lack of interest and lack of cooperation from management of their facilities.The personnel also felt that they did not have sufficient training to implement QC and that QC results were difficult to analyse. Keywords: perception, quality control, personnel, management, diagnostic ...

  3. Control of Solar Energy Systems

    CERN Document Server

    Camacho, Eduardo F; Rubio, Francisco R; Martínez, Diego

    2012-01-01

    Control of Solar Energy Systems details the main solar energy systems, problems involved with their control, and how control systems can help in increasing their efficiency.  After a brief introduction to the fundamental concepts associated with the use of solar energy in both photovoltaic and thermal plants, specific issues related to control of solar systems are embarked upon. Thermal energy systems are then explored in depth, as well as  other solar energy applications such as solar furnaces and solar refrigeration systems. Problems of variable generation profile and of the contribution of many solar plants to the same grid system are considered with the necessary integrated and supervisory control solutions being discussed. The text includes material on: ·         A comparison of basic and advanced control methods for parabolic troughs from PID to nonlinear model-based control; ·         solar towers and solar tracking; ·         heliostat calibration, characterization and off...

  4. The Atomic Energy Control Board

    International Nuclear Information System (INIS)

    Shultz, R.J.

    1980-01-01

    Certain aspects of the Atomic Energy Control Board's relationships with Cabinet, the Minister, Government officials, The licensees and the public are analyzed. The way some of the relationships would have been modified by the Nuclear Control and Administration Act proposed in 1977 is examined. (L.L.)

  5. RENDAC: Integrated System Data for the Information Control the Environmental Radiological Surveillance the National Network in Cuban Republic

    International Nuclear Information System (INIS)

    Valdes Ramos, M.; Prendes Alonso, M.

    1998-01-01

    With the objective to evaluate, process, control and to store the information that is generated in the National Environmental Radiological Surveillance Network, it is designed and I program the on-line RENDAC system that allows to capture and evaluate the parameters that characterize the environmental radiological situation

  6. Software for creating quality control database in diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Spassov, G.; Tabakov, S.

    2000-01-01

    The paper describes a PC based program with database for quality control (QC). It keeps information about all surveyed equipment and measured parameters. The first function of the program is to extract information from old (existing) MS Excel spreadsheets with QC surveys. The second function is used for input of measurements which are automatically organized in MS Excel spreadsheets and built into the database. The spreadsheets are based on the protocols described in the EMERALD Training Scheme. In addition, the program can make statistics of all measured parameters, both in absolute term and in time

  7. RCT: Module 2.08, Radiological Source Control, Course 8774

    Energy Technology Data Exchange (ETDEWEB)

    Hillmer, Kurt T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-10

    radioactive source is material used for its emitted radiation. Sources are sealed or unsealed and are classified as accountable or exempt. Radioactive sources are used for response checks, functional checks, and the calibration of instruments and monitors to traceable standards. To ensure the safety and welfare of all personnel, it is important to maintain control of radioactive sources to minimize the potential for the spread of contamination, unnecessary exposure to personnel, loss or theft, and improper disposal. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

  8. Methodology for performing measurements to release material from radiological control

    International Nuclear Information System (INIS)

    Durham, J.S.; Gardner, D.L.

    1993-09-01

    This report describes the existing and proposed methodologies for performing measurements of contamination prior to releasing material for uncontrolled use at the Hanford Site. The technical basis for the proposed methodology, a modification to the existing contamination survey protocol, is also described. The modified methodology, which includes a large-area swipe followed by a statistical survey, can be used to survey material that is unlikely to be contaminated for release to controlled and uncontrolled areas. The material evaluation procedure that is used to determine the likelihood of contamination is also described

  9. Troubles for the sustainability of the quality assurance in the laboratories of radiological control in Peru

    International Nuclear Information System (INIS)

    Gonzales, Susana; Lopez, Edith

    2008-01-01

    Full text: The Nuclear Energy Peruvian Institute (IPEN) has laboratories which offer services of radiological control. Radiometric analysis in raw and processed foodstuff is requested by several enterprises of both public and private sectors which uses the results for trading purposes like exportation, importation and licitations. The service of assays and calibration with reliable results has become a need due to the external audits performed by accredited laboratories to fulfil the requirements of the Peruvian standard organism. With the support of the International Atomic Energy Agency (IAEA), the IPEN laboratory of radiometric analysis implemented its quality system in 2001 under the ISO IEC 17025 Standard 'General Requirements for the Competence of the Calibration and Testing Laboratories' with the purpose to organize the activities and offer an enhanced service to the clients. The implementation of the quality system has allowed giving a better service with enhanced efficiency to the clients, assuring the reliability of the final output, the analytical results. It had been possible since the laboratories have participated in worldwide proficiency tests sponsored by the IAEA and currently work with reference material. The quality system allows identifying potential faults in any stage of the process in order to prevent any problem in the final output, assuring the appropriate quality of the issued analytical results and to take the necessary corrective actions to avoid those events to happen again. This study has identified and assessed several difficulties and troubles which prevent to fulfil the requirements of the Quality Standard and as a consequence, disable the sustainability of the quality systems and prevent the accreditation. Several proposals and solution alternatives which involve the Executive Staff and the proactive participation of the personnel are presented. (author)

  10. Development and validation of a questionnaire to evaluate infection control in oral radiology

    Science.gov (United States)

    Pinelli, Camila; da Silva Tagliaferro, Elaine P; Corrente, José E; Ambrosano, Glaucia M B

    2017-01-01

    Objectives: To create and validate a questionnaire to evaluate infection control in oral radiology. Methods: The questionnaire was developed after review of the literature, which included published articles and the biosafety protocols available from healthcare agencies. The initial version of the questionnaire was composed of 14 multiple choice questions and was divided into 3 domains on handwashing, disinfection/protection of surfaces and disinfectant used. Content validity was assessed by two expert committees, which reviewed the content and scope of the questionnaire and the relevance of each item, respectively. Reliability was evaluated using test–retest and internal consistency methods with 115 undergraduate dentistry students. Construct validity was assessed using the known-groups technique and factor analysis. The known-groups technique involved 641 undergraduate dentistry students, 20 PhD students and 15 oral radiology professors. In the factor analysis, 3 radiology technicians also participated in addition to the 641 undergraduates, 20 PhD students and 15 oral radiology professors. Results: The content validity results were found to be satisfactory to excellent for the ordinal variables (intraclass correlation coefficient = 0.722–1.000) and good to great for the yes/no questions (kappa = 0.662–0.913) in terms of reliability and good internal consistency (Cronbach's alpha = 0.88). After a factor analysis, some questions were excluded, and the questions were grouped into new domains. Significant differences were observed between answers from different groups. The final version of the questionnaire was composed of nine domains. Conclusions: The questionnaire created was found to exhibit good psychometric properties for assessing infection control in oral radiology. PMID:28112553

  11. Data Integrated System for the control to the security information and radiological protection to national scale

    International Nuclear Information System (INIS)

    Valdes Ramos, M.; Domenech Nieves, H.; Jova Sed, L.

    1998-01-01

    RASSYN was developed to maintain upgraded the national registrations that store the data that allow to the regulatory organ to exercise its function give control and supervision. On the other hand the system serves tool for the emission authorizations, licenses, permits and it facilitates the task inspection. The system notices on time situations that require attention and it values and it correlates the information with view to obtain the national at grade radiological situation or give a territory

  12. Training courses for radiological technicians: radiation protection of the patient and control of image quality

    International Nuclear Information System (INIS)

    Mateus Yoshimura, Elisabeth; Costa, Paulo Roberto; Furquim, Tania Aparecida; Freitas, Marcelo Baptista de; Valente, Marcelo; Cerri, Giovanni Guido

    2008-01-01

    Full text: As in other countries, life expectancy is increasing in Brazil, and the number of radiological examinations tends to increase. Old equipment and high technology ones cohabit, radiology technicians are not well prepared to conduct practices, images and doses to patients are not optimized. Digital techniques that began to be introduced in the last years are also an important issue, because, as it is possible to modify the image digitally, there is less concern about the choice of equipment parameters that produce the best-image/lowest-dose compromise. Pediatric radiology, CT and fluoroscopy require attention too, as they are of dosimetric interest or because the patient ages imply higher risks or because the techniques deliver higher doses than the conventional ones. In our opinion, the most important role that we can play is educating and forming people to work in this area: training programs and refreshing courses are a way of facing the problem. This way, we are organizing, in a technical cooperation with IAEA, two training courses in quality assurance and radiation protection in radiology, one designed to physicists (60 h), and the radiological technicians (40 h). An important cooperation with a paediatric and a general hospital made it possible to offer courses with 50% practical lessons, performed both in the University and in hospital equipment. Both courses cover a basic Radiation Physics program, radiation protection, image formation and quality control in conventional and digital equipment, and patient dosimetry. Equipment donated by IAEA facilitate the practical QA and dosimetry lessons. The rationale of our project is making it sustainable through the formation of physicists that will go on in the education process of technicians in technical schools. We present the results of the first two courses (physicists and technicians), considering the selection process, the development of the activities, and the assessment both of the students enrolled

  13. Guidelines for Quality Control of Equipment Used in Diagnostic Radiology in the Netherlands

    International Nuclear Information System (INIS)

    Berg, L. van den; Aarts, C.N.M.; Beentjes, L.B.; Dalen, A. van; Elsakkers, P.; Julius, H.W.; Kicken, P.J.H.; Meer, F. van der; Teeuwisse, W.; Thijssen, M.A.O.; Zoetelief, J.

    1998-01-01

    The Dutch working group on 'Quality Criteria for Equipment Used in Diagnostic Radiology' has formulated guidelines providing technical criteria for equipment used in conventional diagnostic radiology. These guidelines are applicable to the technical parameters having a major impact on image quality and patient dose and include methods for testing. The following parameters are included: tube voltage, automatic exposure control, film processing, film-screen combination, light tightness and illumination of the dark room, half-value layer and filtration, light field, grid, focal spot size, viewing boxes and geometrical indicators. Each guideline consists of the following chapters: (1) Scope and field of application, (2) Background information, (3) Test procedure, (4) Test frequency, (5) Registration of observations, (6) Evaluation and interpretation, (7) Test report. Chapter 3 includes both the principles of the test method and a step by step description of the procedures. The principles of the test procedure provide a basis for adaptation to local circumstances. The step by step test procedure allows a quality control measurement to be performed with limited physical knowledge of the equipment. Chapter 6 includes limiting values. Draft guidelines were evaluated in practice in 20 hospitals. The final document has been accepted by the professional societies in the Netherlands and the Dutch Minister of Health as a reference set of tools to perform Quality Control of equipment used for conventional diagnostic radiology. (author)

  14. Controlling the radiological impact in the nuclear fuel cycle: a cost/benefit analysis

    International Nuclear Information System (INIS)

    Blanco, R.E.

    1976-01-01

    Methods that are used to control the radiological impact of the nuclear fuel cycle are discussed. This control is exercised through the application of a series of Federal laws and regulations that are used as the basis for licensing nuclear facilities. These licenses contain technical specifications which define the limits for the release of radioactive materials. The control is exercised more directly in a technical sense by the use of radwaste treatment equipment at the nuclear facilities to limit the release of radioactive materials. The first part of this paper contains a summary of the principal Federal laws and regulations that apply to nuclear fuel cycle facilities and a description of how they are applied in licensing procedures. A detailed discussion is presented of the amounts of radioactive materials that may be released from licensed facilities, and the radiological doses that individuals and populations surrounding these facilities would receive from these releases. These doses are then compared with the radiological doses received from natural background radiation to put them in perspective. Cost/benefit engineering surveys which are being made to determine the cost (in dollars) and the effectiveness of radwaste systems for decreasing the release of radioactive materials from model fuel cycle facilities, and to determine the benefits in terms of reduction in dose commitment to individuals and populations in surrounding areas are described

  15. Radiological worker training

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-10-01

    This Handbook describes an implementation process for core training as recommended in Implementation Guide G441.12, Radiation Safety Training, and as outlined in the DOE Radiological Control Standard (RCS). The Handbook is meant to assist those individuals within the Department of Energy, Managing and Operating contractors, and Managing and Integrating contractors identified as having responsibility for implementing core training recommended by the RCS. This training is intended for radiological workers to assist in meeting their job-specific training requirements of 10 CFR 835. While this Handbook addresses many requirements of 10 CFR 835 Subpart J, it must be supplemented with facility-specific information to achieve full compliance.

  16. Radiological worker training

    International Nuclear Information System (INIS)

    1998-10-01

    This Handbook describes an implementation process for core training as recommended in Implementation Guide G441.12, Radiation Safety Training, and as outlined in the DOE Radiological Control Standard (RCS). The Handbook is meant to assist those individuals within the Department of Energy, Managing and Operating contractors, and Managing and Integrating contractors identified as having responsibility for implementing core training recommended by the RCS. This training is intended for radiological workers to assist in meeting their job-specific training requirements of 10 CFR 835. While this Handbook addresses many requirements of 10 CFR 835 Subpart J, it must be supplemented with facility-specific information to achieve full compliance

  17. Basic DTU Wind Energy controller

    DEFF Research Database (Denmark)

    Hansen, Morten Hartvig; Henriksen, Lars Christian

    This report contains a description and documentation, including source code, of the basic DTU Wind Energy controller applicable for pitch-regulated, variable speed wind turbines. The controller features both partial and full load operation capabilities as well as switching mechanisms ensuring......-integral controller to counter the effects of changing dynamics of the wind turbine for different wind speeds. Blade pitch servo and generator models are not included in this controller and should be modeled separately, if they are to be included in the simulations....... dependent minimum blade pitch in partial load operation. The controller uses the collective blade pitch angle and electromagnetic generator torque to control the wind turbine. In full load operation a feedback term from the collective blade pitch angle is used to schedule the gains of the proportional...

  18. Harmonization of radiological of control practices at NPPS. Harmonization in NPPS of the implementation of the instruction IS-31. CSN

    International Nuclear Information System (INIS)

    Fernandez Benitez, B.; Garceran Ortiz, M. A.; Gonzalez Vega, A.; Pardo Benavente, J. M.; Propin Recio, A.; Rivas Goset, A.

    2013-01-01

    Exchange of experiences on the radiological control practices that develop legislation in the Central Spanish nuclear, applied in a manner harmonized in all of them which have demonstrated how more efficient. (Author)

  19. A clinical audit programme for diagnostic radiology: The Approach adopted by the international atomic energy agency

    International Nuclear Information System (INIS)

    Faulkner, K.; Jaervinen, H.; Butler, P.; McLean, I. D.; Pentecost, M.; Rickard, M.; Abdullah, B.

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  20. A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    Science.gov (United States)

    Faulkner, K; Järvinen, H; Butler, P; McLean, I D; Pentecost, M; Rickard, M; Abdullah, B

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  1. Basic DTU Wind Energy controller

    Energy Technology Data Exchange (ETDEWEB)

    Hartvig Hansen, M.; Henriksen, Lars Christian

    2013-01-15

    This report contains a description and documentation, including source code, of the basic DTU Wind Energy controller applicable for pitch-regulated, variable speed wind turbines. The controller features both partial and full load operation capabilities as well as switching mechanisms ensuring smooth switching between the two modes of operation. The partial and full load controllers are both based on classical proportional-integral control theory as well as additional filters such as an optional drive train damper and a notch filter mitigating the influence of rotor speed dependent variations in the feedback. The controller relies on generator speed as the primary feedback sensor. Additionally, the reference generator power is used as a feedback term to smoothen the switching between partial and full load operation. Optionally, a low-pass filtered wind speed measurement can be used for wind speed dependent minimum blade pitch in partial load operation. The controller uses the collective blade pitch angle and electromagnetic generator torque to control the wind turbine. In full load operation a feedback term from the collective blade pitch angle is used to schedule the gains of the proportional-integral controller to counter the effects of changing dynamics of the wind turbine for different wind speeds. Blade pitch servo and generator models are not included in this controller and should be modeled separately, if they are to be included in the simulations. (Author)

  2. The radiological quality of the environment: strategies and methods of control

    International Nuclear Information System (INIS)

    Gazal, Suzanne; Amiard, Jean-Claude; Chenal, Christian; Levasseur, Jacques-Edouard

    2014-01-01

    As the nature of risk, and the relation to it, have evolved, and as events such as industrial catastrophes, hazards related to climate change, or health crisis have modified the problematic of risk and its social acceptability, a strong demand for a reliable and available access to information has emerged among the civil society, as well as a demand of citizen commitment and implication in the expertise process. In this context, the implementation of local information commissions (CLIs) in December 1981 has been an answer to this demand. These structures have been more recently given a specific legal status in a law on transparency and safety in the nuclear sector. Produced by the national association of local information committees and commissions (ANCCLI), this collective publication aims at providing a comprehensive document on strategies and methods of control of the radiological quality of the environment. After a recall of the various components of the eco-sphere (atmospheric, aquatic and ground media) and of their interactions, this book proposes an overview of the various methods of radiological control of the environment (air, water, sediments, soils, fauna, flora, food supply chain, and so on). The first part addresses the detection and the quantification of radioactive contaminants in physical media (atmosphere, water, soil) and in biological organisms and products transformed by man. It details the sources of radioactive pollution and measurements to be performed. It also discusses methodological issues. It addresses the adopted approach to the control of the quality of the environment through the study of biological organisms (bio-indicators), and details available methods for the assessment of direct and indirect biological effects of exposures to low doses of external and internal irradiation. A last part presents the actors of the radiological control of the environment in France, notably the CLIs which are active at the vicinity of nuclear

  3. Top 50 Highly Cited Articles on Dual Energy Computed Tomography (DECT) in Abdominal Radiology: A Bibliometric Analysis

    Science.gov (United States)

    Gong, Bo; Wu, Yuhao; O’Keeffe, Michael E; Berger, Ferco H; McLaughlin, Patrick D; Nicolaou, Savvas

    2017-01-01

    Summary This study aims to identify the 50 most highly cited articles on dual energy computed tomography (DECT) in abdominal radiology Thomson Reuters Web of Science All Databases was queried without year or language restriction. Only original research articles with a primary focus on abdominal radiology using DECT were selected. Review articles, meta-analyses, and studies without human subjects were excluded. Fifty articles with the highest average yearly citation were identified. These articles were published between 2007 and 2017 in 12 journals, with the most in Radiology (12 articles). Articles had a median of 7 authors, with all first authors but one primarily affiliated to radiology departments. The United States of America produced the most articles (16), followed by Germany (13 articles), and China (7 articles). Most studies used Dual Source DECT technology (35 articles), followed by Rapid Kilovoltage Switching (14 articles), and Sequential Scanning (1 article). The top three scanned organs were the liver (24%), kidney (16%), and urinary tract (15%). The most commonly studied pathology was urinary calculi (28%), renal lesion/tumor (23%), and hepatic lesion/tumor (20%). Our study identifies intellectual milestones in the applications of DECT in abdominal radiology. The diversity of the articles reflects on the characteristics and quality of the most influential publications related to DECT. PMID:29657641

  4. Radiological protection and routinary controls of an activimeter with a cesium and barium sources in an nuclear medicine center

    International Nuclear Information System (INIS)

    Morales L, M.E.

    2006-01-01

    In the present work the results when carrying out the routine controls in a Deluxe Isotope (Calibrator II) equipment, with some sources of Cesium 137 and Barium 133, in a Nuclear Medicine Center that operates from the year 1983 in a modern one construction inside the Institute of Neoplastic Illnesses (INEN) are shown. Taking in account the Radiological Protection measures to verify if the equipment responds to the personnel's demands in the measurements of activities of the diverse radionuclides that are used in different types of exams that are carried out in this Nuclear Medicine Center are the objectives of this work. This Center was equipped initially with donated equipment by the International Atomic Energy Agency (IAEA) with those that it develops assistance, educational works and of research, giving services to patients of the INEN and other public and private medical centers. (Author)

  5. Radiological control FY 1995 site support program plan WBS 6.7.2.4

    International Nuclear Information System (INIS)

    1994-09-01

    The 1995 Site Support Program Plan (SSPP) brings year planning and execution year planning into a single document. The plan presented consists of the following four major sections: Overview and Introduction - Health physics has been renamed Radiological Control (RadCon) with the role of protecting workers, the public and the environment from the harmful effects of radiation resulting from the DOE Hanford Site Operations; Cost Baselines which contains cost, technical and schedule baselines; Execution Year work Plan - cost summaries and detailed descriptions of the work to be done; Appendix - including brief description of other project activities directly coupled to RadCon

  6. Radiological control FY 1995 site support program plan WBS 6.7.2.4

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    The 1995 Site Support Program Plan (SSPP) brings year planning and execution year planning into a single document. The plan presented consists of the following four major sections: Overview and Introduction - Health physics has been renamed Radiological Control (RadCon) with the role of protecting workers, the public and the environment from the harmful effects of radiation resulting from the DOE Hanford Site Operations; Cost Baselines which contains cost, technical and schedule baselines; Execution Year work Plan - cost summaries and detailed descriptions of the work to be done; Appendix - including brief description of other project activities directly coupled to RadCon.

  7. U.S. Department of Energy Region 6 Radiological Assistance Program response plan. Revision 2

    International Nuclear Information System (INIS)

    Jakubowski, F.M.

    1998-02-01

    Upon request, the DOE, through the Radiological Assistance Program (RAP), makes available and will provide radiological advice, monitoring, and assessment activities during radiological incidents where the release of radioactive materials is suspected or has occurred. Assistance will end when the need for such assistance is over, or if there are other resources available to adequately address the incident. The implementation of the RAP is usually accomplished through the recommendation of the DOE Regional Coordinating Office's (RCO) on duty Regional Response Coordinator (RRC) with the approval of the Regional Coordinating Office Director (RCOD). The DOE Idaho Operations Office (DOE-ID) is the designated RCO for DOE Region 6 RAP. The purpose of this document is: to describe the mechanism for responding to any organization or private citizen requesting assistance to radiological incidents; to coordinate radiological assistance among participating federal agencies, states, and tribes in DOE Region 6; and to describe the RAP Scaled Response concept of operations

  8. Idaho National Engineering Laboratory Radiological Control Performance Indicator Report. Fourth quarter -- year-end report, Calendar year 1995

    International Nuclear Information System (INIS)

    Reavis, R.

    1996-03-01

    The INEL Radiological Control Performance Indicator Report is comprised of a description of the indicator and the criteria used for measurement. Indicators evaluated in this report include: collective radiation dose; average worker radiation dose; maximum radiation dose to a worker; maximum neutron dose to a worker; number of skin contaminations; number of clothing contaminations; airborne events; total radiological intakes; contamination areas; high contamination area; airborne radioactivity area; and radioactive spills

  9. CHALLENGES IN SETTING UP QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY FACILITIES IN NIGERIA.

    Science.gov (United States)

    Inyang, S O; Egbe, N O; Ekpo, E

    2015-01-01

    The Nigerian Nuclear Regulatory Authority (NNRA) was established to regulate and control the use of radioactive and radiation emitting sources in Nigeria. Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the authorization of diagnostic radiology facilities in the Country. Some quality control tests (output, exposure linearity and reproducibility) were measured on the x-ray machines in the facilities that took part in the study. Questionnaire was developed to evaluate the frequencies at which QC tests were conducted in the facilities and the challenges in setting up QC. Results show great variation in the values of the QC parameters measured. Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study. The responses on the frequencies at which QC tests should be conducted did not correspond to the recommended standards; indicating that personnel were not familiar with QC implementation and may require further training on QC.

  10. Aerial radiological survey of the US Department of Energy's Mound Facility, Miamisburg, Ohio

    International Nuclear Information System (INIS)

    1978-03-01

    An aerial radiological survey to measure terrestrial gamma radiation was carried out by helicopter over an area centered on Mound Facility, a 180 acre area adjacent to the southern edge of the city of Miamisburg, Ohio. This survey was part of an effort to document background radiation levels around nuclear processing and handling facilities owned or contracted by the United States Department of Energy (DOE). Survey activities were conducted and performed by EG and G for the DOE. Wright-Patterson Air Force Base served as the survey base of operations. During the survey, gamma ray data were collected over a 12.3 km 2 area by flying an east-west grid of lines spaced 61 m apart, flying slowly over several selected areas, and hovering over several spots of interest. The processed data indicated that the on-site radioactivity was primarily due to radionuclides currently being handled or processed at the Facility, and that lesser activity could be attributed to previously handled or processed nuclear materials. Off-site data showed the radioactivity to be that only due to naturally occurring radionuclides

  11. Revision of criteria for foodstuffs control following a nuclear or radiological emergency

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Hyun; Lee, Young Min; Jeong, Seung Young [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    GAL(generic action level)s were derived using cost-benefit methods. But the factors used to derive GALs, such as Gross National Product (GNP) and cost of foodstuff, have been changed for last 10 years. Moreover the standards did not consider exposure situation change from emergency exposure to existing exposure situation. In this study, two ways to revise existing standards for foodstuff control were considered; 1st, revision of GAL, 2nd, newly derived reference level. In this study, two methods to revise food control criteria following nuclear emergency were suggested. GAL based on recent GNI and cost of foodstuff would be revised and decreased up to 30 % than existing criteria. DRLs reflecting exposure situation and consumption pattern were smaller than existing criteria for group 1 nuclides. The approach considered in the study would be applied to set up domestic criteria for food control during and following nuclear or radiological emergency.

  12. Revision of criteria for foodstuffs control following a nuclear or radiological emergency

    International Nuclear Information System (INIS)

    Park, Sang Hyun; Lee, Young Min; Jeong, Seung Young

    2015-01-01

    GAL(generic action level)s were derived using cost-benefit methods. But the factors used to derive GALs, such as Gross National Product (GNP) and cost of foodstuff, have been changed for last 10 years. Moreover the standards did not consider exposure situation change from emergency exposure to existing exposure situation. In this study, two ways to revise existing standards for foodstuff control were considered; 1st, revision of GAL, 2nd, newly derived reference level. In this study, two methods to revise food control criteria following nuclear emergency were suggested. GAL based on recent GNI and cost of foodstuff would be revised and decreased up to 30 % than existing criteria. DRLs reflecting exposure situation and consumption pattern were smaller than existing criteria for group 1 nuclides. The approach considered in the study would be applied to set up domestic criteria for food control during and following nuclear or radiological emergency

  13. Operational aspects of the radiological control in a radioisotopes plant production

    International Nuclear Information System (INIS)

    Corahua, A.

    1996-01-01

    The purpose of this paper is to inform about the results obtained in the control operations carried out by the radioprotection area of the radioisotopes plant production during 1994 and then were compared with the limits established by the regulations of radiological radioprotection. In the general inter-texture of the activities that are developed in the radioisotopes plant production, the carried out controls are: area monitoring, air monitoring, personnel monitoring, monitoring in the expedition of radioactive material and monitoring and control in the evacuation of solid and liquid wastes. The result obtained in the present paper states that the doses received by the exposed occupationally staff are below the allowed limits. (author). 3 refs

  14. Intelligent energy management control for independent microgrid

    Indian Academy of Sciences (India)

    Energy management control; multi-agent system; microgrid; energy forecast; hybrid power ... power to the local load most of the time in this energy management strategy. ... Electrical and Electronics Engineering Department, PSG College of ...

  15. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  16. The impact of regulatory control on monitoring of pregnant hospital staff in diagnostic radiology

    International Nuclear Information System (INIS)

    Faulkner, K.; Rawlings, D.J.; Marshall, N.W.

    1997-01-01

    In 1990, the International Commission on Radiological Protection recommended the introduction of a supplementary dose limit for pregnant staff so that the foetus was adequately protected. This dose limit was framed in terms of an abdomen surface dose of 2 mSv for the duration of the pregnancy, once it had been declared. The philosophical basis underlying this supplementary dose limit was the desire to treat the foetus as a member of the public in respect of the occupational exposure of the mother. In the Basic Safety Standards, the International Atomic Energy Agency endorsed the need to limit the foetal dose, but in this document the dose limit refers to the foetus. The introduction of dose limits for foetal exposure to radiation has significant implications for hospitals as many workers are women of child bearing age. The practical implications of this dose limit will be discussed as well as suggested monitoring arrangements. (author)

  17. Radiological control of the junk exports in Cuba; Control radiologico de las exportaciones de chatarra en Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez L, O; Capote F, E; Carrazana G, J A; Zerquera, J T; Ramos V, O; Alonso A, D; Fernandez, I M; Caveda R, C A; Madrazo M, S; Barroso P, I [CPHR, Calle 20 No. 4113 e/41 y 47, Playa, C.P. 11300, A.P. 6195, C.P. 10600 La Habana (Cuba)

    2006-07-01

    Even when in Cuba a strict control exists on the radiation sources that enter to the country to be used in the different applications, it can be given the case that sources or contaminated materials that never were under this control due fundamentally to that entered to the country before the same one existed, appear in the junk that is marketed. In our country it is effective the Combined Resolution CITMA-MINCEX dated on April, 2002 that settles down the necessity and obligation that has all that manipulates, imports, exports or process junk of carrying out it a radiological control. From April, 2002 making use of a minimum of resources, an own methodology, a properly qualified personnel and the support of a credited laboratory by the ISO 17025 standard, the radioactivity measurement service in junk belonging to the Center of Protection and Hygiene of the Radiations (CPHR), it has reduced the risks that sources or contaminated materials are found in the junk that is exported in the main exporter companies of this line in Cuba avoiding possible radiological emergency situations that affect the population and the environment. (Author)

  18. Design of the network for the radiological control in the recycling of metal scrap in Cuba

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Caveda Ramos, Celia; Ramos Viltre, Enma O.; Capote Ferrera, Eduardo; Alonso Abad, Dolores; Zerquera, Juan Tomas

    2008-01-01

    Full text: During the last six years, the Centre of Protection and Hygiene of the Radiations (CPHR) has given answer to the problem about the presence of radioactive materials in the scrap which is exported in Cuba. The service of radioactivity measurement in scraps has reduced the risks of the occurrence of this type of events in the main import and export enterprises in Cuba. This has been carried out using few resources, a properly qualified staff and a laboratory credited by the norm ISO 17025:00. There is not the same control in the enterprises that manipulate and process metallic scrap inside the country. With the objective of extending the radiological control of the metallic scrap to the whole country, a monitoring network was designed. The design was based on the experience accumulated during the years of service to the import and export enterprises. First, It was defined the most vulnerable points in the whole recycle chain for each province, prioritizing the scrap melting plants and the longest scrap yards. All possible scenarios were identified, a quality system was also designed and implemented and a course of Radiological Protection oriented to the metallurgist technicians who are linked with the performance of this practice was elaborated. The monitoring has two phases. First, the measurements are carried out in the measurement points in each province and the transmissions of the data related to the monitored scrap loads are sent to the CPHR. The second phase is the confection of the Declaration of Conformity at the CPHR. This declaration certifies that this scrap may be processed. For the operation of this network, two software were developed and are currently used. One of them allows the control of the information in monitoring point and sends the necessary data to CPHR for the confection of the Declaration of Conformity. The other controls all the information received from the monitoring points and generates the Declaration of Conformity

  19. Evaluation of quality control in the college of medical radiological sciences, conventional x-ray department

    International Nuclear Information System (INIS)

    Babiker, Esameldeen Mohamed Tom

    2002-02-01

    Quality control in diagnostic radiography aims to ensure continuous production of diagnostic images with optimum quality, using minimum necessary dose to the patients and staff. Therefore an ineffective quality control program can lead to poor quality images that can impair diagnosis, increase operating costs and contribute to unnecessary radiation exposure to both patients and staff. Apply basic quality control program is responsibility of each x-ray facility, and to achieve maximum benefits, all levels of management and technical staff must support and participate in operating the programme. The main parameters to be monitored during the quality control programme include: dose consistency, k Vp accuracy, k Vp variations, exposure timer accuracy, besides checking image receptors, recording system and processing conditions. The aims of this project is to evaluate the quality control in the x-ray department of the college of medical radiologic sciences. The evaluation was an experimental study done by checking the operational status of the radiographic equipment, beside data collection using questionnaires regarding quality control. In the applied experiments the results show that there is a noted variation in the accuracy of k Vp, exposure timer and also in the dose consistency. The obtained results from image receptors and processing system showed noted variations too. The results of the questionnaire and direct interviewing showed other causes of quality degradation such as absence of test tools, the status of the equipment, absence of regular quality control testing, in addition to absence of an organized team to deal with quality. (Author)

  20. Quality control in diagnostic radiology. Historical development and present status in Europe

    International Nuclear Information System (INIS)

    Michael Moores, B.

    2007-01-01

    Complete test of publication follows. Quality control is now an accepted activity within the overall radiation protection framework for diagnostic radiology. Indeed it is now a legal requirement within Member States specified in EC Directives that establish the basic requirements for radiation protection in medicine. This was not always the case and its historical development can be considered in three parts: 1) The development of test procedures and standardisation of practices; 2) Harmonisation of initiatives and the creation of a European dimension in such practices; 3) Its role and function in a changing and evolving technological environment - current status and future needs. The development of tests methods for diagnostic X-ray equipment was initially intimately related to the development of a scientific basis for the X-ray imaging process. Knowledge of the physical basis for image production in film-screen and fluoroscopic processes required the definition and specification and measurement of particular parameters within the image forming chain. The development of test methods and the necessary measuring equipment involved ongoing research and development by physical scientists throughout Europe and North America. However, the many different approaches employed meant that results of measurements could not always be compared. However, once acceptable test methods and equipment had been developed it was possible to standardise practices through the development of test protocols. In 1980 a foundation for collective European actions was established through the EC radiation protection research and development programme. This helped to establish a European wide forum for actions in the field of medical radiation protection including quality control. These initiatives were driven by EC Directives, which were concerned with protection of the worker, general public and patients from medical practices that utilised ionising radiation. Multi national research

  1. Radioanalytical laboratory quality control: Current status at Tennessee Valley Authority's western area radiological laboratory

    International Nuclear Information System (INIS)

    Rogers, W.J.

    1986-01-01

    The Tennessee Valley Authority operates a laboratory for radiological analysis of nuclear plant environmental monitoring samples and also for analysis of environmental samples from uranium mining and milling decommissioning activities. The laboratory analyzes some 9,000 samples per year and employs approximately 20 people as analysts, sample collectors, and supervisory staff members. The laboratory is supported by a quality control section of four people involved in computer support, production of radioactive standards, quality control data assessment and reporting, and internal reviews of compliance. The entire laboratory effort is controlled by 60 written procedures or standards. An HP-1000 computer and data base software are used to schedule samples for collection, assign and schedule samples within the laboratory for preparation and analysis, calculate sample activity, review data, and report data outside the laboratory. Gamma spectroscopy systems with nine germanium detectors, an alpha spectroscopy system, five alpha/beta counters, two liquid scintillation counters, four beta-gamma coincidence systems, two sodium iodide single-channel systems, and four photomultipliers for counting Lucas cells are all employed. Each device has various calibration and quality control checks performed on it routinely. Logbooks and control charts are in use for each instrument

  2. The energy control; La maitrise de l'energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-01-15

    Because of strong constraints, the energy control has not been a priority of the public choices. With the market liberalization, the framework of the energy control is modified. But the new program became not sufficient. This study aims to present the necessary new policy of the energy control, which must be integrated in the attitudes and must imply the local government. (A.L.B.)

  3. The energy control; La maitrise de l'energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-01-15

    Because of strong constraints, the energy control has not been a priority of the public choices. With the market liberalization, the framework of the energy control is modified. But the new program became not sufficient. This study aims to present the necessary new policy of the energy control, which must be integrated in the attitudes and must imply the local government. (A.L.B.)

  4. The Spanish system for the radiological surveillance and control of scrap and the products resulting from its processing

    International Nuclear Information System (INIS)

    Gil, E.

    2001-01-01

    Despite the fact that the use of radiation technologies has always been subjected to strict controls in most countries, the presence of radioactive materials in scrap has been detected relatively often in recent years. This has led to the implementation of a series of international initiatives aimed at detecting and preventing illicit international trafficking with radioactive material, intentional or otherwise. The Spanish iron and steel industry is one of the most important industrial sectors in the country, and depends to a large extent on the importing of a significant proportion of the scrap its uses as raw material. Experience has shown that that countries that import large quantities of scrap should complement the aforementioned international initiatives with others of national scope, in order to reduce the risks arising from the presence of radioactive material in scrap. In this context, the Spanish radiological protection authorities, along with the business associations involved in the metal recovery and smelting industry, have established a national system for the radiological surveillance and control of scrap and of the products resulting from its processing. The system consists of a set of legal bases, the installation of specific radiological surveillance equipment and the enhancement of other general purpose equipment that existed prior to these initiatives, the development of radiological training and information plans for the professionals involved in the metal recovery and smelting sectors and improvement to the national radiological emergency response system. (author)

  5. Release protocol to address DOE moratorium on shipments of waste generated in radiologically controlled areas

    International Nuclear Information System (INIS)

    Rathbun, L.A.; Boothe, G.F.

    1992-10-01

    On May 17, 1991 the US DOE Office of Waste Operations issued a moratorium on the shipment of hazardous waste from radiologically contaminated or potentially contaminated areas on DOE sites to offsite facilities not licensed for radiological material. This document describes a release protocol generated by Westinghouse Hanford submitted for US DOE approval. Topics considered include designating Radiological Materials Management Areas (RMMAs), classification of wastes, handling of mixed wastes, detection limits

  6. Experimental measurement of radiological penumbra associated with intermediate energy x-rays (1 MV) and small radiosurgery field sizes

    International Nuclear Information System (INIS)

    Keller, Brian M.; Beachey, David J.; Pignol, Jean-Philippe

    2007-01-01

    Stereotactic radiosurgery is used to treat intracranial lesions with a high degree of accuracy. At the present time, x-ray energies at or above Co-60 gamma rays are used. Previous Monte Carlo simulations have demonstrated that intermediate energy x-ray photons or IEPs (defined to be photons in the energy range of 0.2-1.2 MeV), combined with small field sizes, produce a reduced radiological penumbra leading to a sharper dose gradient, improved dose homogeneity and sparing of critical anatomy adjacent to the target volume. This hypothesis is based on the fact that, for small x-ray fields, a dose outside the treatment volume is dictated mainly by the range of electrons set into motion by x-ray photons. The purpose of this work is: (1) to produce intermediate energy x rays using a detuned medical linear accelerator (2) to characterize the energy of this beam (3) to measure the radiological penumbra for IEPs and small fields to compare with that produced by 6 MV x rays or Co-60, and (4) to compare these experimental measurements with Monte Carlo computer simulations. The maximum photon energy of our IEP x-ray spectrum was measured to be 1.2 MeV. Gafchromic EBT films (ISP Technologies, Wayne, NJ) were irradiated and read using a novel digital microscopy imaging system with high spatial resolution. Under identical irradiation conditions the measured radiological penumbra widths (80%-20% distance), for field sizes ranging from 0.3x0.3 to 4.0x4.0 cm 2 , varied from 0.3-0.77 mm (1.2 MV) and from 1.1-2.1 mm (6 MV). Even more dramatic were the differences found when comparing the 90%-10% or the 95%-5% widths, which are in fact more significant in radiotherapy. Monte Carlo simulations agreed well with the experimental findings. The reduction in radiological penumbra could be substantial for specific clinical situations such as in the treatment of an ocular melanoma abutting the macula or for the treatment of functional disorders such as trigeminal neuralgia (a nonlethal

  7. Development of master slave system for interventional radiology with force-rate control

    International Nuclear Information System (INIS)

    Ide, Masaru; Zobel, P.B.; Claudio, P.D.; Mohri, Makoto; Komeda, Takashi

    2010-01-01

    The objective of this study is to develop a master-slave system for a catheter-guided operation, which is performed by using radiology, through the vascular system. When the master-slave system is used, the surgeon is not exposed to x-rays during the operation. The master tool is managed by an operator away from the slave tool, which is near the patient. The system must provide a realistic picture to the surgeon, particularly in term of force information because this operation is performed by observing three-dimensional fields on a two-dimensional monitor. In this paper, we describe the development of a master slave system that involves the use of force-rate control for guiding the catheter without using force sensors. The master tool has a force-display function. This system can be controlled by force and velocity controlling; hence, this system realized an innovative mechanism and algorism. Finally, the preliminary experiment indicated that the new control method was effective. Further, the force display was stable and achieved fast response. (author)

  8. Quality control of conventional diagnostic radiology equipment in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Ciraj, O.; Kosutic, D.; Markovic, S.

    2003-01-01

    There are more than 1500 diagnostic X-ray tubes in service in Serbia and Montenegro. Diagnostic X-ray equipment is checked on annual basis. X-ray equipment Qc protocols have been adopted from several international standards and guidelines [1,2], which have been modified according our practice and measuring equipment. According our inventory, about one half of all installed units is used for conventional X-ray diagnostics, 10% are mobile units, 2% of all in units in operation are mammographic devices an another 2% are computed tomography units. In addition there are about 600 dental X-ray units, which is 36% of all units. It is worth mentioning that almost 30 % of all installed units have single-phase generators, another 25% are tree phase (six and twelve pulse) generators and nearly 9% are high frequency units. Majority of units was installed more than 25 years ago. The Quality Control (QC) in radiography is a central part of QA programme, which deals with equipment maintenance and monitoring. QA in diagnostic radiology is a mean of maintaining standards in imaging and working towards minimizing patient and staff doses. As a part of QA programme in diagnostic radiology, the performance characteristics of 96 conventional X-ray units were measured in six months period during 2003. The diagnostic units were located in hospitals all over the country. They represent 25% of the total conventional diagnostic units of the country. About one half of measured X-ray units were new-installed. QC program has positive effect on X-ray equipment performance in a period of a few years. It is essential to perform QC tests for all installed X-ray units at least on annual basis. This would lead to production of consistent X-ray images, with minimal retake rate and hence, will contribute to decreasing of the patient dose. Patient doses are determined by multitude factors which interact in very complicated manner. It is very important to perform real patient dose measurements in

  9. Controller for a wave energy converter

    Science.gov (United States)

    Wilson, David G.; Bull, Diana L.; Robinett, III, Rush D.

    2015-09-22

    A wave energy converter (WEC) is described, the WEC including a power take off (PTO) that converts relative motion of bodies of the WEC into electrical energy. A controller controls operation of the PTO, causing the PTO to act as a motor to widen a wave frequency spectrum that is usable to generate electrical energy.

  10. Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT.

    Science.gov (United States)

    Shi, Bowen; Lin, Huimin; Zhang, Miao; Lu, Wei; Qu, Ying; Zhang, Huan

    2018-01-22

    Gastric cancer remains fourth in cancer incidence worldwide with a five-year survival of only 20%-30%. Peritoneal metastasis is the most frequent type of metastasis that accompanies unresectable gastric cancer and is a definitive determinant of prognosis. Preventing and controlling the development of peritoneal metastasis could play a role in helping to prolong the survival of gastric cancer patients. A non-invasive and efficient imaging technique will help us to identify the invasion and metastasis process of peritoneal metastasis and to monitor the changes in tumor nodules in response to treatments. This will enable us to obtain an accurate description of the development process and molecular mechanisms of gastric cancer. We have recently described experiment using dual energy CT (DECT) and positron emission tomography/computed tomography (PET/CT) platforms for the detection and monitoring of gastric tumor metastasis in nude mice models. We have shown that weekly continuous monitoring with DECT and PET/CT can identify dynamic changes in peritoneal metastasis. The sFRP1-overexpression in gastric cancer mice models showed positive radiological performance, a higher FDG uptake and increasing enhancement, and the SUVmax (standardized uptake value) of nodules demonstrated an obvious alteration trend in response to targeted therapy of TGF-β1 inhibitor. In this article, we described the detailed non-invasive imaging procedures to conduct more complex research on gastric cancer peritoneal metastasis using animal models and provided representative imaging results. The use of non-invasive imaging techniques should enable us to better understand the mechanisms of tumorigenesis, monitor tumor growth, and evaluate the effect of therapeutic interventions for gastric cancer.

  11. Development of a calibration methodology for instruments used to interventional radiology quality control

    International Nuclear Information System (INIS)

    Miranda, Jurema Aparecida de

    2009-01-01

    Interventional radiology is the technique where X radiation images are used as a tool in the conduction of diagnostic or/and therapeutic procedures. The exposition times are long for both procedures, diagnostic and therapeutic, may cause serious injuries in the patient, and also contribute to the dose of the clinical staff. In Brazil there are not yet well established rules to determine the doses and to make the dosimetry in fluoroscopic beams. There is great interest in this study, in relation to the beam quality, the half-value-layer, and others parameters. In this work a Medicor Neo Diagnomax clinical X ray generator, fluoroscopy mode, was used to develop a calibration methodology for instruments used in interventional radiology quality control. One plane parallel ionization chamber PTW was used as monitor. The ionization chambers recommended for fluoroscopy measurements had been evaluated and calibrated in relation to the IPEN Calibration Laboratory reference ionization chamber. The RQR3, RQR5 and RQR7 radiation qualities and the specific ones for fluoroscopy, RQC3, RQC5 and RQC7, were established following the norm IEC 61267. All beams characteristics were determined. Ionization chambers positioning system and the acrylic phantoms to the entrance and exit doses determination were developed and constructed. The results obtained show air kerma rates of 4.5x10 -3 , 1.2x10 -2 and 1.9x10 -2 Gy/min for RQC3, RQC5 and RQC7 respectively. Tests with and without the collimation just after the monitor chamber, were carried out and the results showed a difference of +5.5%, +0.6% e + 0.8%, confirming the importance of the collimation use in these interventionist procedures. (author)

  12. Radiology today

    International Nuclear Information System (INIS)

    Donner, M.W.; Heuck, F.H.W.

    1981-01-01

    The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)

  13. Aerial radiological survey of the United States Department of Energy's Rocky Flats Plant, Golden, Colorado. Date of survey, August 1981

    International Nuclear Information System (INIS)

    1982-09-01

    An aerial radiological survey of the Rocky Flats Plant was conducted during August 1981. The survey consisted of an airborne measurement of both natural and man-made gamma radiation from the terrain surface in and around the Rocky Flats Plant. These measurements allowed an estimate of the distribution of isotope concentrations in the survey area. Results are reported as exposure rate, man-made, and 241 Am isopleths superimposed on photographs of the area. The survey covered a square area approximately 9.7 km on each side. Gamma ray energy spectra are also presented for the net man-made radionuclides

  14. From quality control to quality systems in x-ray radiology. Step by step approach

    International Nuclear Information System (INIS)

    Gendrutis Morkunas; Julius Ziliukas

    2007-01-01

    Complete test of publication follows. Quality systems in x-ray radiology as in any area of medical exposure is an important tool of optimization of radiation protection. Creation of these systems is related with a number of problems: limited resources, lack of knowledge and experience, negative attitude of hospitals staff and administration, lack of advice from outside. Problems related with transitionary period might be softened by the step by step approach. The following steps might be indicated: providing information on quality systems to hospital staff and administration, simple quality control procedures done by outside experts in hospitals, preparation of quality related procedures by hospital staff, practical implementation of quality control procedures done by hospital staff, preparation of quality manual by hospital staff, its integration into common quality system of hospital (if it is available) and constant development, measurements of performance indicators (e.g., patients' doses) and introduction of corrective measures if necessary, dissemination of experience by expert organizations and more advanced hospitals. These steps are to be discussed in the presentations based on Lithuanian experience since 1998.

  15. Effective radiological contamination control and monitoring techniques in high alpha environments.

    Science.gov (United States)

    Funke, Kevin C

    2003-02-01

    In the decommissioning of a highly contaminated alpha environment, such as the one at Hanford's 233-S Plutonium Concentration Facility, one of the key elements of a successful radiological control program is an integrated safety approach. This approach begins with the job-planning phase where the scope of the work is described. This is followed by a brainstorming session involving engineering and craft to identify how to perform the work in a logical sequence of events. Once the brainstorming session is over, a Job Hazard Analysis is performed to identify any potential problems. Mockups are utilized to enable the craft to get hands on experience and provide feedback and ideas to make the job run smoother. Ideas and experience gained during mockups are incorporated into the task instruction. To assure appropriate data are used in planning and executing the job, our principal evaluation tools included lapel and workplace air sampling, plus continuous air monitors and frequent surveys to effectively monitor job progress. In this highly contaminated alpha environment, with contamination levels ranging from 0.3 Bq cm-2 to approximately 100,000 Bq cm-2 (2,000 dpm per 100 cm2 to approximately 600 million dpm per 100 cm2), with average working levels of 1,600-3,200 Bq cm-2 (10-20 million dpm per 100 cm2) without concomitant ambient radiation levels, control of the spread of contamination is key to keeping airborne levels As Low As Reasonably Achievable.

  16. Nuclear and radiological safety. 1986-1998. International Atomic Energy Agency publications

    International Nuclear Information System (INIS)

    1999-04-01

    This catalogue lists all sales publications of the IAEA dealing with nuclear and radiological safety issued from 1986 to 1998. Publications are sorted according to the following subjects: Uranium mining and milling; Fuel fabrication and storage; Nuclear power plants; Research reactors; Radiation sources and accelerators; Transport of radioactive material; Waste repositories; Radiation protection; Accident response; Radioactive waste management; Safety analysis; Quality management; Legal and governmental aspects

  17. Nuclear and radiological safety. 1990-2001. International Atomic Energy Agency publications

    International Nuclear Information System (INIS)

    2001-08-01

    This catalogue lists all sales publications of the IAEA dealing with nuclear and radiological safety issued from 1990 to 2001. Publications are sorted according to the following subjects: Uranium mining and milling. Fuel fabrication and storage. Nuclear power plants. Research reactors. Radiation sources and accelerators. Transport of radioactive material. Waste repositories. Radiation protection. Accident response. Radioactive waste management. Safety analysis. Quality management. Legal and governmental aspects

  18. Nuclear and radiological safety. 1990-2001. International Atomic Energy Agency publications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-08-01

    This catalogue lists all sales publications of the IAEA dealing with nuclear and radiological safety issued from 1990 to 2001. Publications are sorted according to the following subjects: Uranium mining and milling. Fuel fabrication and storage. Nuclear power plants. Research reactors. Radiation sources and accelerators. Transport of radioactive material. Waste repositories. Radiation protection. Accident response. Radioactive waste management. Safety analysis. Quality management. Legal and governmental aspects.

  19. Metal recycling experience at Los Alamos National Laboratory. Reuse, release, and recycle of metals from radiological control areas

    International Nuclear Information System (INIS)

    Gogol, S.

    1997-01-01

    Approximately 15% of the Low-Level Waste (LLW) produced at Los Alamos consists of scrap metal equipment and materials. The majority of this material is produced by decommissioning and the modification of existing facilities. To reduce this waste stream, Department of Energy Headquarters, EM-77 Office, sponsored the Reuse, Recycle, and Release of Metals from Radiological Control Areas High Return on Investment (ROI) Project to implement recycle, reuse, and release of scrap metal at the laboratory. The goal of this project was to develop cost effective alternatives to LLW disposal of scrap metal and to avoid the disposal of 2,400 m 3 of scrap metal. The ROI for this project was estimated at 948%. The ROI project was funded in March 1996 and is scheduled for completion by October 1997. At completion, a total of 2,400 m 3 of LLW avoidance will have been accomplished and a facility to continue recycling activities will be operational. This paper will present the approach used to develop effective alternatives for scrap metal at Los Alamos and then discuss the tasks identified in the approach in detail. Current scrap metal inventory, waste projections, alternatives to LLW disposal, regulatory guidance, and efforts to institutionalize the alternatives to LLW disposal will be discussed in detail

  20. Optimal control of a wave energy converter

    NARCIS (Netherlands)

    Hendrikx, R.W.M.; Leth, J.; Andersen, P; Heemels, W.P.M.H.

    2017-01-01

    The optimal control strategy for a wave energy converter (WEC) with constraints on the control torque is investigated. The goal is to optimize the total energy delivered to the electricity grid. Using Pontryagin's maximum principle, the solution is found to be singular-bang. Using higher order

  1. Air and smear sample calculational tool for Fluor Hanford Radiological control

    International Nuclear Information System (INIS)

    BAUMANN, B.L.

    2003-01-01

    A spreadsheet calculation tool was developed to automate the calculations performed for determining the concentration of airborne radioactivity and smear counting as outlined in HNF--13536, Section 5.2.7, ''Analyzing Air and Smear Samples''. This document reports on the design and testing of the calculation tool. Radiological Control Technicians (RCTs) will save time and reduce hand written and calculation errors by using an electronic form for documenting and calculating work place air samples. Current expectations are RCTs will perform an air sample and collect the filter or perform a smear for surface contamination. RCTs will then survey the filter for gross alpha and beta/gamma radioactivity and with the gross counts utilize either hand calculation method or a calculator to determine activity on the filter. The electronic form will allow the RCT with a few key strokes to document the individual's name, payroll, gross counts, instrument identifiers; produce an error free record. This productivity gain is realized by the enhanced ability to perform mathematical calculations electronically (reducing errors) and at the same time, documenting the air sample

  2. Quality Control in Radiological Unit of Three Hospitals in Makurdi, Benue State

    International Nuclear Information System (INIS)

    Akaagerger, N.B.

    2013-01-01

    Quality Control in Radiological units of three hospitals in Makurdi, Benue State, designed A, B and C, was done using beam alignment and collimator test tool on single phase diagnostic X-ray machines. The collimator and beam alignment tests were used to measure the degree of misalignment of the target point. The results of this work shows that the misalignment falls within the acceptable limit. Hospital A (Federal Medical Center, Makurdi), has a misalignment of 0.2cm at 60KVp, 10mAs, 100cm FFD, film size of 10 x 8cm square. Hospital B (Bishop Murray Medical Center, Makurdi) has a misalignment of 0.6cm at 60KVp, 25mAs, 81cm FFD and a film size of 10 x 8cm square and Hospital C (Hemko Hospital, Makurdi) has a misalignment of 0.8cm at 60KVp, 20mA s, 88cm FFD and a film size of 10 x 8cm-square. These show that Hospital A has the least misalignment, followed by B, with C as the highest. These results also show the misalignment fall within 2.0cm as recommended by ICRP.

  3. Thermal energy storage apparatus, controllers and thermal energy storage control methods

    Science.gov (United States)

    Hammerstrom, Donald J.

    2016-05-03

    Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

  4. Automatic control algorithm effects on energy production

    Science.gov (United States)

    Mcnerney, G. M.

    1981-01-01

    A computer model was developed using actual wind time series and turbine performance data to simulate the power produced by the Sandia 17-m VAWT operating in automatic control. The model was used to investigate the influence of starting algorithms on annual energy production. The results indicate that, depending on turbine and local wind characteristics, a bad choice of a control algorithm can significantly reduce overall energy production. The model can be used to select control algorithms and threshold parameters that maximize long term energy production. The results from local site and turbine characteristics were generalized to obtain general guidelines for control algorithm design.

  5. 30 years of the energy control

    International Nuclear Information System (INIS)

    2003-01-01

    Since the first petroleum crisis in 1973 and the creation of the Agency for the Energy Conservation, the France transformed its energy policy. This film presents the historical aspects of this new energy policy, the changes in the consumption attitudes to adapt the technical and economical control of the energy to a long dated evaluation of the development in a social, economical and environmental point of view. (A.L.B.)

  6. The Role of the International Atomic Energy Agency in a Response to Nuclear and Radiological Incidents and Emergencies

    Energy Technology Data Exchange (ETDEWEB)

    Buglova, E.; Baciu, F., E-mail: E.Buglova@iaea.org [International Atomic Energy Agency (IAEA), Department of Nuclear Safety and Security, Wagramer Strasse 5, P.O. Box 100, 1400 Vienna (Austria)

    2014-10-15

    Full text: The role of the International Atomic Energy Agency (IAEA) in a response to nuclear and radiological incidents and emergencies has been defined and further expanded through the IAEA Statute, the Convention on Early Notification of a Nuclear Accident, the Convention on Assistance in the Case of a Nuclear Accident or Radiological Emergency, the Convention on Physical Protection of Nuclear Material, IAEA safety standards, relevant decisions by Policy Making Organs of the IAEA, inter-agency agreements and other documents such as the IAEA Action Plan on Nuclear Safety. The IAEA Secretariat fulfils its roles through the Agency's Incident and Emergency System (IES) and the Incident and Emergency Centre (IEC). The IEC is the global focal point for international preparedness and response to nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest and for coordination of International assistance. During a response the IEC performs and facilitates for Member States many specific functions which include: prompt notification; official information exchange; assessment of potential consequences; prognosis of emergency progression; provision, facilitation and coordination of International assistance; provision of timely, accurate and easily understandable public information; coordination of inter-agency response at the International level. Through officially designated contact points of Member States the IEC is able to communicate at any time with national authorities to ensure the prompt and successful sharing of information and resources. The IEC routinely performs internal exercising of all aspects of the IAEA response and in cooperation with Member States, the IAEA organizes and facilitates the conduct of large scale international exercises to practice cooperation and coordination. This presentation outlines in detail the specific functions of the IAEA IEC during a response. (author)

  7. Guide for radiological characterization and measurements for decommissioning of US Department of Energy surplus facilities

    Energy Technology Data Exchange (ETDEWEB)

    Denahm, D. H.; Barnes, M. G.; Jaquish, R. E.; Corley, J. P.; Gilbert, R. O.; Hoenes, G. R.; Jamison, J. D.; McMurray, B. J.; Watson, E. C.

    1983-08-01

    This Guide describes the elements of radiological characterization at DOE excess facilities in preparation for, during, and subsequent to decommissioning operations. It is the intent of this Guide and accompanying appendices to provide the reader (user) with sufficient information to carry out that task with a minimum of confusion and to provide a uniform basis for evaluating site conditions and verifying that decommissioning operations are conducted according to a specific plan. Some areas of particular interest in this Guide are: the need to involve appropriate staff from the affected states in the early planning stages of decommissioning; the need for and suggested methods of radiological site characterization to complete a decommissioning project, including: historical surveys, environmental pathway analyses, statistical sampling design, and choosing appropriate instrumentation and measurements; the need for and emphasis on quality assurance, documentation and records retention; the establishment of a Design Objective approach to applying site-specific contamination limits based on the ALARA philosophy; the establishment of a ''de minimis'' or minimum dose level of concern for decommissioning operations based on existing standards, experience and ALARA considerations.

  8. Guide for radiological characterization and measurements for decommissioning of US Department of Energy surplus facilities

    International Nuclear Information System (INIS)

    Denahm, D.H.; Barnes, M.G.; Jaquish, R.E.; Corley, J.P.; Gilbert, R.O.; Hoenes, G.R.; Jamison, J.D.; McMurray, B.J.; Watson, E.C.

    1983-08-01

    This Guide describes the elements of radiological characterization at DOE excess facilities in preparation for, during, and subsequent to decommissioning operations. It is the intent of this Guide and accompanying appendices to provide the reader (user) with sufficient information to carry out that task with a minimum of confusion and to provide a uniform basis for evaluating site conditions and verifying that decommissioning operations are conducted according to a specific plan. Some areas of particular interest in this Guide are: the need to involve appropriate staff from the affected states in the early planning stages of decommissioning; the need for and suggested methods of radiological site characterization to complete a decommissioning project, including: historical surveys, environmental pathway analyses, statistical sampling design, and choosing appropriate instrumentation and measurements; the need for and emphasis on quality assurance, documentation and records retention; the establishment of a Design Objective approach to applying site-specific contamination limits based on the ALARA philosophy; the establishment of a ''de minimis'' or minimum dose level of concern for decommissioning operations based on existing standards, experience and ALARA considerations

  9. The Northern Marshall Islands radiological survey: A quality control program for radiochemical and gamma spectroscopy analysis

    International Nuclear Information System (INIS)

    Kehl, S.R.; Mount, M.E.; Robison, W.L.

    1995-09-01

    From 1979 to 1989, approximately 25,000 Post Northern Marshall Islands Radiological Survey (PNMIRS) samples were collected, and over 71,400 radiochemical and gamma spectroscopy analyses were performed to establish the concentration of 90 Sr, 137 Cs, 241 Am, and plutonium isotopes in soil, vegetation, fish, and animals in the Northern Marshall Islands. While the Low Level Gamma Counting Facility (B379) in the Health and Ecological Assessment (HEA) division accounted for over 80% of all gamma spectroscopy analyses, approximately 4889 radiochemical and 5437 gamma spectroscopy analyses were performed on 4784 samples of soil, vegetation, terrestrial animal, and marine organisms by outside laboratories. Four laboratories were used by Lawrence Livermore National Laboratory (LLNL) to perform the radiochemical analyses: Thermo Analytical Norcal, Richmond, California (TMA); Nuclear Energy Services, North Carolina State University (NCSU); Laboratory of Radiation Ecology, University of Washington (LRE); and Health and Ecological Assessment (HEA) division, LLNL, Livermore, California. Additionally, LRE and NCSU were used to perform gamma spectroscopy analyses. The analytical precision and accuracy were monitored by including blind duplicates and natural matrix standards in each group of samples analyzed. On the basis of reported analytical values for duplicates and standards, 88% of the gamma and 87% of the radiochemical analyses in this survey were accepted. By laboratory, 93% of the radiochemical analyses by TMA; 88% of the gamma-ray spectrometry and 100% of the radiochemistry analyses by NCSU; 89% of the gamma spectroscopy and 87% of the radiochemistry analyses by LRE; and 90% of the radiochemistry analyses performed by HEA's radiochemistry department were accepted

  10. Energy spectrum control for modulated proton beams

    International Nuclear Information System (INIS)

    Hsi, Wen C.; Moyers, Michael F.; Nichiporov, Dmitri; Anferov, Vladimir; Wolanski, Mark; Allgower, Chris E.; Farr, Jonathan B.; Mascia, Anthony E.; Schreuder, Andries N.

    2009-01-01

    In proton therapy delivered with range modulated beams, the energy spectrum of protons entering the delivery nozzle can affect the dose uniformity within the target region and the dose gradient around its periphery. For a cyclotron with a fixed extraction energy, a rangeshifter is used to change the energy but this produces increasing energy spreads for decreasing energies. This study investigated the magnitude of the effects of different energy spreads on dose uniformity and distal edge dose gradient and determined the limits for controlling the incident spectrum. A multilayer Faraday cup (MLFC) was calibrated against depth dose curves measured in water for nonmodulated beams with various incident spectra. Depth dose curves were measured in a water phantom and in a multilayer ionization chamber detector for modulated beams using different incident energy spreads. Some nozzle entrance energy spectra can produce unacceptable dose nonuniformities of up to ±21% over the modulated region. For modulated beams and small beam ranges, the width of the distal penumbra can vary by a factor of 2.5. When the energy spread was controlled within the defined limits, the dose nonuniformity was less than ±3%. To facilitate understanding of the results, the data were compared to the measured and Monte Carlo calculated data from a variable extraction energy synchrotron which has a narrow spectrum for all energies. Dose uniformity is only maintained within prescription limits when the energy spread is controlled. At low energies, a large spread can be beneficial for extending the energy range at which a single range modulator device can be used. An MLFC can be used as part of a feedback to provide specified energy spreads for different energies.

  11. American College of Radiology-American Brachytherapy Society practice parameter for electronically generated low-energy radiation sources.

    Science.gov (United States)

    Devlin, Phillip M; Gaspar, Laurie E; Buzurovic, Ivan; Demanes, D Jeffrey; Kasper, Michael E; Nag, Subir; Ouhib, Zoubir; Petit, Joshua H; Rosenthal, Seth A; Small, William; Wallner, Paul E; Hartford, Alan C

    This collaborative practice parameter technical standard has been created between the American College of Radiology and American Brachytherapy Society to guide the usage of electronically generated low energy radiation sources (ELSs). It refers to the use of electronic X-ray sources with peak voltages up to 120 kVp to deliver therapeutic radiation therapy. The parameter provides a guideline for utilizing ELS, including patient selection and consent, treatment planning, and delivery processes. The parameter reviews the published clinical data with regard to ELS results in skin, breast, and other cancers. This technical standard recommends appropriate qualifications of the involved personnel. The parameter reviews the technical issues relating to equipment specifications as well as patient and personnel safety. Regarding suggestions for educational programs with regard to this parameter,it is suggested that the training level for clinicians be equivalent to that for other radiation therapies. It also suggests that ELS must be done using the same standards of quality and safety as those in place for other forms of radiation therapy. Copyright © 2017 American Brachytherapy Society and American College of Radiology. Published by Elsevier Inc. All rights reserved.

  12. Comparison of time-oriented cost accounting catalogs to control a Departement of Radiology

    International Nuclear Information System (INIS)

    Hacklaender, T.; Mertens, H.; Cramer, B.M.

    2005-01-01

    Purpose: Within a hospital, the radiology department has taken over the role of a cost center. Cost accounting can be applied to analyze the cost for the performance of services. By assigning the expenditures of resources to the service, the cash value can directly be distributed to the costs of equipment, material and rooms. Time-oriented catalogs of services are predefined to calculate the number of the employees for a radiology department. Using our own survey of time data, we examined whether such catalogs correctly represent the time consumed in a radiology department. Only services relevant for the turnover were compared. Materials and Methods: For 96 primary radiological services defined by the score-oriented German fee catalog for physicians (Gebuehrenordnung fuer Aerzte), a ranking list was made for the annual procedures in descending frequency order. According to the Pareto principle, the 11 services with the highest frequency were chosen and the time consumed for the technical and medical services was collected over a period of 2 months. This survey was compared with the time-oriented catalogs TARMED and EBM 2000plus. Results: The included 11 relevant radiological services represented 80.3% of the annual procedures of our radiology department. When comparing the technical services between the time-oriented catalogs and our own survey, TARMED gives a better description of the time consumed in 7 of the 11 services and EMB 2000plus in 3 services. When comparing the medical services, TARMED gives a better description of the time consumed in 6 of the 11 services and EBM 2000plus in 4 services. When averaging all the radiological services, TARMED overestimates the current number of physicians necessary for primary reading by a factor of 10.0% and EBM 2000plus by a factor of 2.6%. Conclusion: As to the time spent on performing the relevant radiological services. TARMED is slightly superior to describe the radiology department of a hospital than EBM 2000plus

  13. Radiation dose assessments to support evaluations of radiological control levels for recycling or reuse of materials and equipment

    International Nuclear Information System (INIS)

    Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.

    1995-07-01

    Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed

  14. Radiation dose assessments to support evaluations of radiological control levels for recycling or reuse of materials and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.

    1995-07-01

    Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed.

  15. Guide for: environmental radiological surveillance at US Department of Energy installations

    International Nuclear Information System (INIS)

    Corley, J.P.; Denham, D.H.; Jaquish, R.E.; Michels, D.E.; Olsen, A.R.; Waite, D.A.

    1981-07-01

    This second edition of the Guide, originally published in 1977, is presented as an interim revision and does not contain major changes in content. The original objectives and scope of the Guide have not changed. The Guide is intended to: provide recommended methods, procedures, and performance criteria to bring greater comparability to DOE environmental monitoring and reporting systems; provide DOE management, particularly the Headquarters' Operational and Environmental Safety Division (OESD) and field offices, with a broad review of accepted radiological surveillance practices for use in the evaluation of environmental surveillance programs at DOE facilities; and delineate the capabilities and limitations of the various environmental monitoring systems for radioactivity currently used at DOE sites, including technical areas where there is either an inadequate basis for procedural selection or where further development work may be warranted. The document is intended as a guide, not a manual of detailed mandatory procedure

  16. Energy Management Dynamic Control Topology In MANET

    Science.gov (United States)

    Madhusudan, G.; Kumar, TNR

    2017-08-01

    Topology management via per-node transmission power adjustment has been shown effective in extending network lifetime. The existing algorithms constructs static topologies which fail to take the residual energy of network nodes, and cannot balance energy consumption efficiently. To address this problem, a Light Weighted Distributed Topology Control algorithm EMDCT(Energy Management Dynamic Control Topology ) is proposed in this paper. Based on the link metric of the network, both the energy consumption rate level and residual energy levels at the two end nodes are considered. EMDCT generates a Dynamic Topology that changes with the variation of node energy without the aid of location information, each node determines its transmission power according to local network information, which reduces the overhead complexity of EMDCT greatly. The experiment results show that EMDCT preserves network connectivity and manitains minimum-cost property of the network also it can extend network lifetime more remarkably.

  17. Atomic energy control board. History backgrounder

    International Nuclear Information System (INIS)

    1986-10-01

    The Atomic Energy Control Board (AECB) is a regulatory agency set up by the Government of Canada under the Atomic Energy Control Act of 1946 to assist the Government in its efforts to make provision for the control and supervision of the development, application and use of atomic energy and to enable Canada to participate effectively in measures of international control of atomic energy. It is also responsible for the administration of the Nuclear Liability Act, including the designation of nuclear installations and the prescription of basic insurance to be carried by the operators of such nuclear installations. An overview is presented of the AECB's evolution in chronological form, its major current activities, and some of the challenges expected in the next decade

  18. Radiological accidents potentially important to human health risk in the U.S. Department of Energy waste management program

    International Nuclear Information System (INIS)

    Mueller, C.; Roglans-Ribas, J.; Folga, S.; Nabelssi, B.; Jackson, R.

    1995-01-01

    Human health risks as a consequence of potential radiological releases resulting from plausible accident scenarios constitute an important consideration in the US Department of Energy (DOE) national program to manage the treatment, storage, and disposal of wastes. As part of this program, the Office of Environmental Management (EM) is currently preparing a Programmatic Environmental Impact Statement (PEIS) that evaluates the risks that could result from managing five different waste types. This paper (1) briefly reviews the overall approach used to assess process and facility accidents for the EM PEIS; (2) summarizes the key inventory, storage, and treatment characteristics of the various DOE waste types important to the selection of accidents; (3) discusses in detail the key assumptions in modeling risk-dominant accidents; and (4) relates comparative source term results and sensitivities

  19. Energy efficient control of a refrigeration plant

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Larsen, Lars F. S.

    2009-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The new idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed and used in a backstepping design...... and the methods are evaluated with respect to energy efficiency....

  20. Robust Control of Laddermill Wind Energy System

    NARCIS (Netherlands)

    Podgaets, A.R.; Ockels, W.J.

    2007-01-01

    Laddermill flight control problem with closed loop is considered in this paper. Laddermill is an alternative concept for energy production using high altitude kites. The kites have been simulated as rigid bodies and the cable as a thin elastic line. Euler angles and cable speed are controls. Flight

  1. Whither the legal control of nuclear energy?

    International Nuclear Information System (INIS)

    Riley, Peter

    1995-01-01

    International nuclear trade is governed by the regime of legal control of nuclear energy, nuclear materials, knowledge of nuclear processes and weapons. Nuclear trade is under pinned by international agreements concerning physical protection and safeguards, the control of nuclear weapons, the protection of nuclear materials from terrorist action and third part liability. The political and geographical boundary changes of the past two years have significantly altered the background against which this regime has developed. Such changes have affected nuclear trade. The paper summarised the legal control of nuclear energy between States, identifies the areas of change which may affect this regime and the consequences for international trade. Conclusions are drawn as to the development of the international legal control of nuclear energy. (author). 21 refs

  2. The efficacy of a continuous quality improvement (CQI) method in a radiological department: comparison with non-CQI control material

    International Nuclear Information System (INIS)

    Laurila, J.; Standertskjoeld-Nordenstam, C.G.; Suramo, I.; Tolppanen, E.M.; Tervonen, O.; Korhola, O.; Brommels, M.

    2000-01-01

    To study the efficacy of continuous quality improvement (CQI) compared to ordinary management in an on-duty radiology department. Because of complaints regarding delivery of on-duty radiological services, an improvement was initiated simultaneously at two hospitals, at the HUCH (Helsinki University Central Hospital) utilising the CQI-method, and at the OUH (Oulu University Hospital) with a traditional management process. For the CQI project, a team was formed to evaluate the process with flow-charts, cause and effect diagrams, Pareto analysis and control charts. Interventions to improve the process were based on the results of these analyses. The team at the HUCH implemented the following changes: A radiologist was added to the evening shift between 15:00 - 22:00 and a radiographer was moved from the morning shift to 15:00 - 22:00. A clear improvement was achieved in the turn-around time, but in the follow-up some of the gains were lost. Only minimal changes were achieved at the OUH, where the intervention was based on traditional management processes. CQI was an effective method for improving the quality of performance of a radiology department compared with ordinary management methods, but some of this improvement may be subsequently lost without a continuous measurement system

  3. Standards to develop energy control and energy efficiency in Europe

    International Nuclear Information System (INIS)

    Plazy, J.L.; Moutet, C.

    2007-01-01

    Since the late nineties, an energy control standardisation steering body was set up at the AFNOR, prompted by the French administration and ADEME which is chairing it. That body, which became a forum in 2006 brings together stakeholders in various areas concerned by that issue (industries, construction, transport, environment, services,...) as well as the representatives of main companies, professional organisations and standardisation operators acting in the area / of energy in France. Its purpose is to help exchange information and express needs in terms of standardisation in the area of energy and energy efficiency. On its initiative, the European standardisation committees CEN and CENELEC set up in 2002 an equivalent body responsible for the strategic coordination of their energy management programmes and entrusted the steering to our country (ADEME chairing, AFNOR secretariat). In order to better serve the interests of its members, the French forum is now working towards the leadership, in partnership with China, of the strategic standardisation group being set up at the ISO (International Standardisation Organisation) on energy efficiency and renewable energy sources. (authors)

  4. Radiological framework for the disposal of materials from geothermal energy facilities in repositories; Radiologische Rahmenbedingungen fuer eine Entsorgung von Materialien der Geothermie auf Deponien

    Energy Technology Data Exchange (ETDEWEB)

    Gellermann, Rainer; Nickstadt, Kristin [Nuclear Control and Consulting GmbH, Braunschweig (Germany)

    2014-10-01

    During utilization of deep geothermal energy sources NORM waste accumulate with radiological properties similar to the residues from crude oil or natural gas production or water treatment plants. The specific activities of these waste materials are in the range from less than 1 Bq/g to more than 1000 Bq/g. The estimated total annual amount of radiological relevant materials (scales, combustible materials, scrap metals) is about 5 to 6 tons with a total activity of about 0.4 GBq Ra-226 and about 2 GBq Pb-210. The established disposal paths for metal waste exist.

  5. Electrical energy consumption control apparatuses and electrical energy consumption control methods

    Science.gov (United States)

    Hammerstrom, Donald J.

    2012-09-04

    Electrical energy consumption control apparatuses and electrical energy consumption control methods are described. According to one aspect, an electrical energy consumption control apparatus includes processing circuitry configured to receive a signal which is indicative of current of electrical energy which is consumed by a plurality of loads at a site, to compare the signal which is indicative of current of electrical energy which is consumed by the plurality of loads at the site with a desired substantially sinusoidal waveform of current of electrical energy which is received at the site from an electrical power system, and to use the comparison to control an amount of the electrical energy which is consumed by at least one of the loads of the site.

  6. Computer program for storage of historical and routine safety data related to radiologically controlled facilities

    International Nuclear Information System (INIS)

    Marsh, D.A.; Hall, C.J.

    1984-01-01

    A method for tracking and quick retrieval of radiological status of radiation and industrial safety systems in an active or inactive facility has been developed. The system uses a mini computer, a graphics plotter, and mass storage devices. Software has been developed which allows input and storage of architectural details, radiological conditions such as exposure rates, current location of safety systems, and routine and historical information on exposure and contamination levels. A blue print size digitizer is used for input. The computer program retains facility floor plans in three dimensional arrays. The software accesses an eight pen color plotter for output. The plotter generates color plots of the floor plans and safety systems on 8 1/2 x 11 or 20 x 30 paper or on overhead transparencies for reports and presentations

  7. Radiotherapy of malignant growths in the eosophagus with clinical and radiological course control

    International Nuclear Information System (INIS)

    Holzhausen, B.

    1981-01-01

    This paper reports on clinical and radiological symptoms observed before during and after radiotherapy of 172 patients treated under high-voltage conditions at the radiological clinic in Muenster in the time from 1962 to 1977. The 1, 2, and 5 year survival rates are 26.5%, 13%, and 5.9%. The examination carried out retrospectively showed in 52% of the patients (46/90) after radiotherapy an expansion of the tumour stenosis. In 67% of the patients (67/101), the disphagia which had been stated before decreased. Thus the palliative effect of the treatment is the most important issue of the therapy. In the case of polypous and diffusely infiltrating tumours, the average survival rate was 11.2 months and 12.3 months which is significantly better than the results obtained with circular-stenosing tumours (6.4 months). (orig./APR) [de

  8. Radiological Protection and Environmental Monitoring in Bolivia

    International Nuclear Information System (INIS)

    MartInez Pacheco, J.

    1979-01-01

    The paper describes the main activities of the Department of Radiological Protection, Nuclear Energy Commission of Bolivia. The following topics are covered: organization, environmental control of air, water, milk and plants, personal dosimetry, instrumentation and calibration, protection in uranium mines. Standard setting and international cooperation aspects are also presented

  9. Energy Optimal Control of Induction Motor Drives

    DEFF Research Database (Denmark)

    Abrahamsen, Flemming

    This thesis deals with energy optimal control of small and medium-size variable speed induction motor drives for especially Heating, Ventilation and Air-Condition (HVAC) applications. Optimized efficiency is achieved by adapting the magnetization level in the motor to the load, and the basic...... demonstrated that energy optimal control will sometimes improve and sometimes deteriorate the stability. Comparison of small and medium-size induction motor drives with permanent magnet motor drives indicated why, and in which applications, PM motors are especially good. Calculations of economical aspects...... improvement by energy optimal control for any standard induction motor drive between 2.2 kW and 90 kW. A simple method to evaluate the robustness against load disturbances was developed and used to compare the robustness of different motor types and sizes. Calculation of the oscillatory behavior of a motor...

  10. Beam energy control device for thermonuclear device

    International Nuclear Information System (INIS)

    Arimoto, Kimiko.

    1991-01-01

    The present invention comprises a setting section for the previously allowed penetration ratio, a correlation graph setting section for the penetration ratio, a beam energy and a plasma density, a control clock output section for transmitting clocks for every control period, a plasma density collecting section for collecting a plasma density from a plasma main body and a calculating section for a beam energy based on the plasma density. Since the value of the beam energy is controlled on real time based on the density of the plasma main body and the correlation graph of the penetration rate, the beam energy and the plasma density is used as a calculation parameter to conduct calculation such that the penetrating ratio is constant, there is no worry that beams at a high energy are entered to plasmas of low density, to damage a vacuum vessel. Further, when a state of plasmas is satisfactory, beams at an effective energy value can be entered as much as possible, thereby enabling to improve heating efficiency. (N.H.)

  11. Synchronous generator wind energy conversion control system

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros, A.L.R. [Wind Energy Group, Recife (Brazil); Lima, A.M.N.; Jacobina, C.B.; Simoes, F.J. [DEE, Campina Grande (Brazil)

    1996-12-31

    This paper presents the performance evaluation and the design of the control system of a WECS (Wind Energy Conversion System) that employs a synchronous generator based on its digital simulation. The WECS discussed in this paper is connected to the utility grid through two Pulse Width Modulated (PWM) power converters. The structure of the proposed WECS enables us to achieve high performance energy conversion by: (i) maximizing the wind energy capture and (ii) minimizing the reactive power flowing between the grid and the synchronous generator. 8 refs., 19 figs.

  12. Wind energy systems control engineering design

    CERN Document Server

    Garcia-Sanz, Mario

    2012-01-01

    IntroductionBroad Context and MotivationConcurrent Engineering: A Road Map for EnergyQuantitative Robust ControlNovel CAD Toolbox for QFT Controller DesignOutline Part I: Advanced Robust Control Techniques: QFT and Nonlinear SwitchingIntroduction to QFTQuantitative Feedback TheoryWhy Feedback? QFT OverviewInsight into the QFT TechniqueBenefits of QFTMISO Analog QFT Control SystemIntroductionQFT Method (Single-Loop MISO System)Design Procedure OutlineMinimum-Phase System Performance SpecificationsJ LTI Plant ModelsPlant Templates of P?(s), P( j_i )Nominal PlantU-Contour (Stability Bound)Trackin

  13. Nuclear and energies nr 57. Japan, another glance. The environmental and radiological impact. The international impact. The illusion of renewable energies in Japan

    International Nuclear Information System (INIS)

    Lenail, B.

    2011-07-01

    The contributions of this publication first address the Japanese local context (organization, mentality, cultural background, thinking and action modes), and secondly the environmental and radiological impact of the Fukushima accident, notably in comparison with Chernobyl (contamination is much more localized, sometimes higher; a larger concerned population but quicker and more efficient protection measures; more severe consequences due to population displacement). The third article discusses the international impact of the accident: known or foreseen consequences on nuclear programs, discussion on safety strengthening and on governance, evolution of public opinion, possible consequences on climate negotiations. The last article proposes an overview of the current situation of Japan which must mobilize all the available energy resources to face the difficulties in electricity supply

  14. Sampling on radiological protection training in diagnostic radiology

    International Nuclear Information System (INIS)

    Gaona, E.

    2001-01-01

    Radiological security aspects were evaluated in radiology departments from Mexico City. The study was carried out in two stages, the first one evaluated 40 departments just before the implementation of the new Official Mexican Standards related to Radiological Security and Quality Control in Radiology; in the second stage 33 departments were evaluated 2 years after those standards were implanted, showing a favorable impact of the training programs for the type of answers obtained [es

  15. Electron beam accelerator energy control system

    International Nuclear Information System (INIS)

    Sharma, Vijay; Rajan, Rehim; Acharya, S.; Mittal, K.C.

    2011-01-01

    A control system has been developed for the energy control of the electron beam accelerator using PLC. The accelerating voltage of 3 MV has been obtained by using parallel coupled voltage multiplier circuit. A autotransformer controlled variable 0-10 KV DC is fed to a tube based push pull oscillator to generate 120 Khz, 10 KV AC. Oscillator output voltage is stepped up to 0-300 KV/AC using a transformer. 0-300 KVAC is fed to the voltage multiplier column to generate the accelerating voltage at the dome 0-3 MV/DC. The control system has been designed to maintain the accelerator voltage same throughout the operation by adjusting the input voltage in close loop. Whenever there is any change in the output voltage either because of beam loading or arcing in the accelerator. The instantaneous accelerator voltage or energy is a direct proportional to 0-10 KVDC obtained from autotransformer. A PLC based control system with user settable energy level has been installed for 3 MeV, EB accelerator. The PLC takes the user defined energy value through a touch screen and compares it to the actual accelerating voltage (obtained using resistive divider). Depending upon the error the PLC generates the pulses to adjust the autotransformer to bring the actual voltage to the set value within the window of error (presently set to +/- 0.1%). (author)

  16. Radiological English

    Energy Technology Data Exchange (ETDEWEB)

    Ribes, R. [Hospital Reina Sofia, Cordoba (Spain). Servicio de Radiologia; Ros, P.R. [Harvard Medical School, Boston, MA (United States). Div. of Radiology

    2007-07-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  17. Radiological English

    International Nuclear Information System (INIS)

    Ribes, R.; Ros, P.R.

    2007-01-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  18. Control and automation, and energy system engineering

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tai-hoon [Hannam Univ., Daejeon (Korea, Republic of); Adeli, Hojjat [Ohio State Univ., Columbus, OH (United States); Stoica, Adrian [Jet Propulsion Laboratory, Pasadena, CA (United States); Kang, Byeong-Ho (eds.) [Tasmania Univ., Hobart, TAS (Australia)

    2011-07-01

    This book comprises selected papers of the International Conferences, CA and CES3 2011, held as Part of the Future Generation Information Technology Conference, FGIT 2011, in Conjunction with GDC 2011, Jeju Island, Korea, in December 2011. The papers presented were carefully reviewed and selected from numerous submissions and focused on the various aspects of control and automation, and circuits, control, communication, electricity, electronics, energy, system, signal and simulation. (orig.)

  19. Current aspects in the development of the quality control in the conventional X-ray diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Velkova, K.

    2004-01-01

    The role of the X-ray diagnostic radiology as one of the main factors forming the general public dose is indisputable. Following the requirement for justification of the application of X-rays for medical purposes, certain criteria for assessment of the parameters of the X-ray diagnostic equipment are formed and maximum permissible values defined. The latter are developed by the international and national radiation protection organizations and introduced both in the international and national legislation. The importance of the quality assurance concept for the radiation protection of the patient and staff in diagnostic radiology turned the quality control into main toll for obtaining high quality images with minimum dose to the patient and staff. X-ray diagnostics is one of the most common methods used in the medical practice. This is the main reason for the increase of the quality control protocols, winch makes their handling difficult. The latest developments in this area bring forward the idea for the development of specialized quality control software, which is capable of: 1) full or semi-automated calculation and assessment of the parameters of the X-ray diagnostic units; 2) tools for data handling and access; 3) tools for data analysis based on predefined procedures

  20. Quality Control Samples for the Radiological Determination of Tritium in Urine Samples

    International Nuclear Information System (INIS)

    Ost'pezuk, P.; Froning, M.; Laumen, S.; Richert, I.; Hill, P.

    2004-01-01

    The radioactive decay product of tritium is a low energy beta that cannot penetrate the outer dead layer of human skin. Therefore , the main hazard associated with tritium is internal exposure. In addition, due to the relatively long half life and short biological half life, tritium must be ingested in large amounts to pose a significant health risk. On the other hand, the internal exposure should be kept as low as practical. For incorporation monitoring of professional radiation workers the quality control is of utmost importance. In the Research Centre Juelich GmbH (FZJ) a considerable fraction of monitoring by excretion analysis relates to the isotope Tritium. Usually an aliquot of an urine sample is mixed with a liquid scintillator and measured in a liquid scintillation counter. Quality control samples in the form of three kind of internal reference samples (blank, reference samples with low activity and reference sample with elevated activity) were prepared from a mixed, Tritium (free) urine samples. 1 ml of these samples were pipetted into a liquid scintillation vial. In the part of theses vials a known amounts of Tritium were added. All these samples were stored at 20 degrees. Based on long term use of all these reference samples it was possible to construct appropriate control charts with the upper and lower alarm limits. Daily use of these reference samples decrease significantly the risk for false results in original urine with no significant increase of the determination time. (Author) 2 refs

  1. Smart energy control systems for sustainable buildings

    CERN Document Server

    Spataru, Catalina; Howlett, Robert; Jain, Lakhmi

    2017-01-01

    There is widespread interest in the way that smart energy control systems, such as assessment and monitoring techniques for low carbon, nearly-zero energy and net positive buildings can contribute to a Sustainable future, for current and future generations. There is a turning point on the horizon for the supply of energy from finite resources such as natural gas and oil become less reliable in economic terms and extraction become more challenging, and more unacceptable socially, such as adverse public reaction to ‘fracking’. Thus, in 2016 these challenges are having a major influence on the design, optimisation, performance measurements, operation and preservation of: buildings, neighbourhoods, cities, regions, countries and continents. The source and nature of energy, the security of supply and the equity of distribution, the environmental impact of its supply and utilization, are all crucial matters to be addressed by suppliers, consumers, governments, industry, academia, and financial institutions. Thi...

  2. Radiology fundamentals

    CERN Document Server

    Singh, Harjit

    2011-01-01

    ""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag

  3. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  4. Radiological emergencies due to unaccounted sources or failures of the control system in developing countries

    International Nuclear Information System (INIS)

    Stainhaeusler, F.; Wieland, P.

    1998-01-01

    The widespread use of radiological sources in developing countries represents a potentially significant risk. Two examples of accident scenarios of different severities - one in El Salvador, the other in Taiwan - are reviewed in the light of their causes, effects on man and the environment, and economic consequences. Recent operational and regulatory advances on improved emergency management are discussed. The international dimension of these issues is significant, as over 160 industrial irradiation facilities comparable to the installation in El Salvador are currently in operation worldwide and close to 40 cases are known of radioactive sources accidentally smelted with recycled metal, as is likely to have happened in Taiwan. (author)

  5. Advanced Energy Harvesting Control Schemes for Marine Renewable Energy Devices

    Energy Technology Data Exchange (ETDEWEB)

    McEntee, Jarlath [Ocean Renewable Power Company, Portland, ME (United States); Polagye, Brian [Ocean Renewable Power Company, Portland, ME (United States); Fabien, Brian [Ocean Renewable Power Company, Portland, ME (United States); Thomson, Jim [Ocean Renewable Power Company, Portland, ME (United States); Kilcher, Levi [Ocean Renewable Power Company, Portland, ME (United States); Marnagh, Cian [Ocean Renewable Power Company, Portland, ME (United States); Donegan, James [Ocean Renewable Power Company, Portland, ME (United States)

    2016-03-31

    The Advanced Energy Harvesting Control Schemes for Marine Renewable Energy Devices (Project) investigated, analyzed and modeled advanced turbine control schemes with the objective of increasing the energy harvested by hydrokinetic turbines in turbulent flow. Ocean Renewable Power Company (ORPC) implemented and validated a feedforward controller to increase power capture; and applied and tested the controls on ORPC’s RivGen® Power Systems in Igiugig, Alaska. Assessments of performance improvements were made for the RivGen® in the Igiugig environment and for ORPC’s TidGen® Power System in a reference tidal environment. Annualized Energy Production (AEP) and Levelized Cost of Energy (LCOE) improvements associated with implementation of the recommended control methodology were made for the TidGen® Power System in the DOE reference tidal environment. System Performance Advancement (SPA) goals were selected for the project. SPA targets were to improve Power to Weight Ratio (PWR) and system Availability, with the intention of reducing Levelized Cost of Electricity (LCOE). This project focused primarily reducing in PWR. Reductions in PWR of 25.5% were achieved. Reductions of 20.3% in LCOE were achieved. This project evaluated four types of controllers which were tested in simulation, emulation, a laboratory flume, and the field. The adaptive Kω2 controller performs similarly to the non-adaptive version of the same controller and may be useful in tidal channels where the mean velocity is continually evolving. Trends in simulation were largely verified through experiments, which also provided the opportunity to test assumptions about turbine responsiveness and control resilience to varying scales of turbulence. Laboratory experiments provided an essential stepping stone between simulation and implementation on a field-scale turbine. Experiments also demonstrated that using “energy loss” as a metric to differentiate between well-designed controllers operating at

  6. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    International Nuclear Information System (INIS)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A.; Fernandes, Angela; Westphalen, Fernando Henrique

    2013-01-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  7. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A., E-mail: alanacarolinef@gmail.com, E-mail: sergei@utfpr.edu.br [Universidade Tecnologica Federal do Parana (CPGEI/UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduacao em Engenharia Eletrica e Informatica Industrial; Fernandes, Angela; Westphalen, Fernando Henrique, E-mail: angelafernandes@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Setor de Ciencias da Saude

    2013-07-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  8. Control development of radiation protection and safety on personnel eye lens of interventional radiology

    International Nuclear Information System (INIS)

    Titik Kartika; Ishak

    2013-01-01

    The review on radiation protection and safety to the lens of personnel especially in interventional radiology activities has been carried out. The use of radiation in interventional radiology installations provide significant exposure to the lens of the eye, especially personnel. The results of the latest various surveys and researches on the effects of low dose radiation to the eye lens indicates that the eye lens dose threshold is less than the preconceived values. Based on these facts, recently, ICRP and IAEA provides recommendations regarding the reduction of the value of the eye lens dose limit for personnel. BAPETEN have adopted the value of the eye lens dose limit in the development of new regulations on radiation protection and safety. However, the application of this provision has various challenges that BAPETEN provide 3 (three) years transitional period. These challenges include the problem of monitoring the eye lens dose, the eye lens protective equipment which is not adequate, the lack of understanding of personnel related to the risk of low radiation to the eye lens, as well as the proper procedures to mitigate those risks. BAPETEN as a regulatory agency is expected to provide solutions to the problems faced by the stake holders. Therefore, to answer the challenge, it is necessary to develop better monitoring of radiation protection and safety. (author)

  9. Energy Efficiency of Distributed Environmental Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, H. Ezzat; Isik, Can; Dannenhoffer, John F. III

    2011-02-23

    In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant

  10. Radiology illustrated. Pediatric radiology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In-One (ed.) [Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiology

    2014-11-01

    Depicts characteristic imaging findings of common and uncommon diseases in the pediatric age group. Will serve as an ideal diagnostic reference in daily practice. Offers an excellent teaching aid, with numerous high-quality illustrations. This case-based atlas presents images depicting the findings typically observed when imaging a variety of common and uncommon diseases in the pediatric age group. The cases are organized according to anatomic region, covering disorders of the brain, spinal cord, head and neck, chest, cardiovascular system, gastrointestinal system, genitourinary system, and musculoskeletal system. Cases are presented in a form resembling teaching files, and the images are accompanied by concise informative text. The goal is to provide a diagnostic reference suitable for use in daily routine by both practicing radiologists and radiology residents or fellows. The atlas will also serve as a teaching aide and a study resource, and will offer pediatricians and surgeons guidance on the clinical applications of pediatric imaging.

  11. Cartel control in the energy sector

    International Nuclear Information System (INIS)

    Buedenbender, U.

    1995-01-01

    The current regulatory regime governing the electricity and gas supply industries of the energy sector is characterized by the admissibility of protected sales areas defined by demarcation agreements. However, this economic advantage is counterbalanced by legal provisions providing for specific supervision of the utilities under cartel law. The cartel authority exercises the functions of control of abusive practices, focussing on control of prices and general terms and conditions, cooperation between the utilities and operators owners of power generation plants, the very topical aspects of TPA (third party access to networks), and adherence to the principle of conduct of business of the utilities in line with the conditions of free competition. The book addresses all relevant aspects of cartel control relating to existing law and the overall context of the energy sector. General principles of cartel control in the economic sector at large are compared to specific conditions in the energy sector, revealing the differences in competences of the cartel authority. (orig./HP) [de

  12. Revisiting control establishments for emerging energy hubs

    Science.gov (United States)

    Nasirian, Vahidreza

    Emerging small-scale energy systems, i.e., microgrids and smartgrids, rely on centralized controllers for voltage regulation, load sharing, and economic dispatch. However, the central controller is a single-point-of-failure in such a design as either the controller or attached communication links failure can render the entire system inoperable. This work seeks for alternative distributed control structures to improve system reliability and help to the scalability of the system. A cooperative distributed controller is proposed that uses a noise-resilient voltage estimator and handles global voltage regulation and load sharing across a DC microgrid. Distributed adaptive droop control is also investigated as an alternative solution. A droop-free distributed control is offered to handle voltage/frequency regulation and load sharing in AC systems. This solution does not require frequency measurement and, thus, features a fast frequency regulation. Distributed economic dispatch is also studied, where a distributed protocol is designed that controls generation units to merge their incremental costs into a consensus and, thus, push the entire system to generate with the minimum cost. Experimental verifications and Hardware-in-the-Loop (HIL) simulations are used to study efficacy of the proposed control protocols.

  13. Acceptance of technology-enhanced learning for a theoretical radiological science course: a randomized controlled trial.

    Science.gov (United States)

    Nkenke, Emeka; Vairaktaris, Elefterios; Bauersachs, Anne; Eitner, Stephan; Budach, Alexander; Knipfer, Christoph; Stelzle, Florian

    2012-03-30

    Technology-enhanced learning (TEL) gives a view to improved education. However, there is a need to clarify how TEL can be used effectively. The study compared students' attitudes and opinions towards a traditional face-to-face course on theoretical radiological science and a TEL course where students could combine face-to-face lectures and e-learning modules at their best convenience. 42 third-year dental students were randomly assigned to the traditional face-to-face group and the TEL group. Both groups completed questionnaires before the beginning and after completion of the course on attitudes and opinions towards a traditional face-to-face lectures and technology-enhanced learning. After completion of the course both groups also filled in the validated German-language TRIL (Trierer Inventar zur Lehrevaluation) questionnaire for the evaluation of courses given at universities. Both groups had a positive attitude towards e-learning that did not change over time. The TEL group attended significantly less face-to-face lectures than the traditional group. However, both groups stated that face-to-face lectures were the basis for education in a theoretical radiological science course. The members of the TEL group rated e-mail reminders significantly more important when they filled in the questionnaire on attitudes and opinions towards a traditional face-to-face lectures and technology-enhanced learning for the second time after completion of the course. The members of the technology-enhanced learning group were significantly less confident in passing the exam compared to the members of the traditional group. However, examination results did not differ significantly for traditional and the TEL group. It seems that technology-enhanced learning in a theoretical radiological science course has the potential to reduce the need for face-to-face lectures. At the same time examination results are not impaired. However, technology-enhanced learning cannot completely replace

  14. Acceptance of technology-enhanced learning for a theoretical radiological science course: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Nkenke Emeka

    2012-03-01

    Full Text Available Abstract Background Technology-enhanced learning (TEL gives a view to improved education. However, there is a need to clarify how TEL can be used effectively. The study compared students' attitudes and opinions towards a traditional face-to-face course on theoretical radiological science and a TEL course where students could combine face-to-face lectures and e-learning modules at their best convenience. Methods 42 third-year dental students were randomly assigned to the traditional face-to-face group and the TEL group. Both groups completed questionnaires before the beginning and after completion of the course on attitudes and opinions towards a traditional face-to-face lectures and technology-enhanced learning. After completion of the course both groups also filled in the validated German-language TRIL (Trierer Inventar zur Lehrevaluation questionnaire for the evaluation of courses given at universities. Results Both groups had a positive attitude towards e-learning that did not change over time. The TEL group attended significantly less face-to-face lectures than the traditional group. However, both groups stated that face-to-face lectures were the basis for education in a theoretical radiological science course. The members of the TEL group rated e-mail reminders significantly more important when they filled in the questionnaire on attitudes and opinions towards a traditional face-to-face lectures and technology-enhanced learning for the second time after completion of the course. The members of the technology-enhanced learning group were significantly less confident in passing the exam compared to the members of the traditional group. However, examination results did not differ significantly for traditional and the TEL group. Conclusions It seems that technology-enhanced learning in a theoretical radiological science course has the potential to reduce the need for face-to-face lectures. At the same time examination results are not impaired

  15. Acceptance of technology-enhanced learning for a theoretical radiological science course: a randomized controlled trial

    Science.gov (United States)

    2012-01-01

    Background Technology-enhanced learning (TEL) gives a view to improved education. However, there is a need to clarify how TEL can be used effectively. The study compared students' attitudes and opinions towards a traditional face-to-face course on theoretical radiological science and a TEL course where students could combine face-to-face lectures and e-learning modules at their best convenience. Methods 42 third-year dental students were randomly assigned to the traditional face-to-face group and the TEL group. Both groups completed questionnaires before the beginning and after completion of the course on attitudes and opinions towards a traditional face-to-face lectures and technology-enhanced learning. After completion of the course both groups also filled in the validated German-language TRIL (Trierer Inventar zur Lehrevaluation) questionnaire for the evaluation of courses given at universities. Results Both groups had a positive attitude towards e-learning that did not change over time. The TEL group attended significantly less face-to-face lectures than the traditional group. However, both groups stated that face-to-face lectures were the basis for education in a theoretical radiological science course. The members of the TEL group rated e-mail reminders significantly more important when they filled in the questionnaire on attitudes and opinions towards a traditional face-to-face lectures and technology-enhanced learning for the second time after completion of the course. The members of the technology-enhanced learning group were significantly less confident in passing the exam compared to the members of the traditional group. However, examination results did not differ significantly for traditional and the TEL group. Conclusions It seems that technology-enhanced learning in a theoretical radiological science course has the potential to reduce the need for face-to-face lectures. At the same time examination results are not impaired. However, technology

  16. Minimum energy control and optimal-satisfactory control of Boolean control network

    International Nuclear Information System (INIS)

    Li, Fangfei; Lu, Xiwen

    2013-01-01

    In the literatures, to transfer the Boolean control network from the initial state to the desired state, the expenditure of energy has been rarely considered. Motivated by this, this Letter investigates the minimum energy control and optimal-satisfactory control of Boolean control network. Based on the semi-tensor product of matrices and Floyd's algorithm, minimum energy, constrained minimum energy and optimal-satisfactory control design for Boolean control network are given respectively. A numerical example is presented to illustrate the efficiency of the obtained results.

  17. A comparison of the radiological impact of energy production by fission and fusion reactions

    International Nuclear Information System (INIS)

    Rancillac, F.; Despres, A.

    1990-04-01

    The impacts of respectively a light water reactor and a planned fusion reactor, for which tritium-deuterium fusion reactions will act as energy source have been compared. The comparison is made on the basis of a generated capacity of 1 GWe.year, using the following criteria: fuel inventories, radioactive releases, collective effective dose equivalent commitments to the public and the volume of wastes. The accidental risk is not introduced. Fusion reactor parameters are still subject to uncertainties, which prevent accurate quantification of radionuclide releases (tritium apart) from the nuclear plant. Only orders of magnitude extrapolated from values for the NET tokamak are given. Despite these uncertainties, it would seem more interesting, from the dosimetric point of view, to use fusion reactors to produce electricity, although problems of radioactive releases, handling and long-term storage of radioactive waste would remain. Fusion reactors also generate generate high-level wastes with long-term exposure rates that are lower than those of light water reactors [fr

  18. Industrial accidents in radiological controlled areas: the importance of radiation protection in the organisation of the emergency aid

    International Nuclear Information System (INIS)

    Fenolland, J.L.; Laporte, E.

    2003-01-01

    After some disappointments when the first French nuclear units were started, it became clear that all the aspects linked to radio-protection needed to be taken into account in the context of emergency aid in the case of an industrial accident in radiological controlled area. In the case of an accident involving people, on-site first aid is provided by permanent services of the power plant. These teams are trained in first aid and fire-fighting. They are well trained in radioprotection. The specificity of an industrial event in controlled zone is that the victims' conventional injuries, whether it be a wound, a burn or a fracture, can be complicated by radioactive contamination. If it is justified, the exterior emergency services (firemen and medical teams) sire immediately called in. These teams are not necessarily trained in radioprotection. (authors)

  19. Performance Analysis: Control of Hazardous Energy

    Energy Technology Data Exchange (ETDEWEB)

    De Grange, Connie E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Freeman, Jeff W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kerr, Christine E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-10-06

    LLNL experienced 26 occurrences related to the control of hazardous energy from January 1, 2008 through August 2010. These occurrences were 17% of the total number of reported occurrences during this 32-month period. The Performance Analysis and Reporting Section of the Contractor Assurance Office (CAO) routinely analyzes reported occurrences and issues looking for patterns that may indicate changes in LLNL’s performance and early indications of performance trends. It became apparent through these analyses that LLNL might have experienced a change in the control of hazardous energy and that these occurrences should be analyzed in more detail to determine if the perceived change in performance was real, whether that change is significant and if the causes of the occurrences are similar. This report documents the results of this more detailed analysis.

  20. Adaptive control of solar energy collector systems

    CERN Document Server

    Lemos, João M; Igreja, José M

    2014-01-01

    This book describes methods for adaptive control of distributed-collector solar fields: plants that collect solar energy and deliver it in thermal form. Controller design methods are presented that can overcome difficulties found in these type of plants:they are distributed-parameter systems, i.e., systems with dynamics that depend on space as well as time;their dynamics is nonlinear, with a bilinear structure;there is a significant level of uncertainty in plant knowledge.Adaptive methods form the focus of the text because of the degree of uncertainty in the knowledge of plant dynamics. Parts

  1. Control of radiological impacts in deactivated uranium mine - the portuguese experience

    International Nuclear Information System (INIS)

    Pereira, Alcides; Neves, Luis

    2011-01-01

    The exploration of radioactive ores occurred in Portugal during around 100 years, and on that period 4370 tons were produced of uranium concentrate, and an estimated total of 13 millions of tons of residues, of various type and variable dangerous grade. From the year 2000 that the government has been performed studies on environmental characterization at the mining areas and remediation project as well. The precise evaluation of the environmental impacts implies the the knowledge of prior work situation, nonexistent for the case of Portuguese mines. This work proposes a methodology for exceeding that limitation focused on selection of area sited at the same metallogenetic province, and considered representative of background. The radiological impacts are checked by the effective dose calculated for reference groups of the exposed population, at this region and in the principal mining area at Portugal (Urgeirica), at the end of exploration and after the finalization of some remediation works

  2. Radiological Worker Training: Radiological Worker 2 study guides

    International Nuclear Information System (INIS)

    1992-10-01

    Upon completion of this training course, the participant will have the knowledge to work safely in areas controlled for radiological purposes using proper radiological practices. Radiological Worker H Training, for the worker whose job assignment involves entry into Radiological Buffer Areas and all types of Radiation Contamination and Airborne Radioactivity Areas. This course is designed to prepare the worker to work safely in and around radiological areas and present methods to use to ensure individual radiation exposure is maintained As Low As Reasonably Achievable

  3. Wind energy generation and pollution control

    International Nuclear Information System (INIS)

    Mohibullah; Mohd Nishat Anwar

    2009-01-01

    Full text: In India, power generation from wind has emerged as one of the most successful programme. It is making meaningful contributions to the overall power requirements in some of the states. India is emerging as fifth nation in wind power generation. As per the projections made by Ministry of New and Renewable Energy, Govt. of India, 10 % of the total capacity of power generation will come from renewable energy sources by the year 2012. It is envisaged that 50 % of this capacity may come from wind power alone. The paper describes a WECS (Wind Energy Conversion Systems) structure implemented in the MATLAB-Simulink simulation environment by using the specialized PSB toolbox, designed for modeling and simulation of electrical equipment. A study is made to show effectiveness in pollution control. An analytical study is also made regarding the potential of wind energy in limiting the amount of green house gases added into the atmosphere per year in different states in India. The amount of green house gases which are saved in the process are calculated for nine wind potential sites in India. The amount of green house gases saved is considerable to reduce environmental pollution and saving in carbon credit. Approximately an amount of 70681 Euro per year may be saved if the scheme is implemented and use of wind energy known in India is fully utilized for power generation. (author)

  4. Imaging and radiology

    Science.gov (United States)

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  5. Chronicle of pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, Gabriele; Richter, Ernst

    2012-01-01

    The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).

  6. Quality control procedures of dental diagnostic radiology systems; Elaboracao de um procedimento para controle de qualidade em sistemas de radiodiagnostico odontologico

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Paula Serra Sasaki

    2007-07-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  7. Digital systems to acquire radiological imaging. Characteristics and quality control; Sistemas digitales de adquisicion de imagenes radiograficas. Caracteristicas y Control de Calidad

    Energy Technology Data Exchange (ETDEWEB)

    Torres Cabrera, R.; Hernando Gonzalez, I.

    2006-07-01

    Due to its special characteristics, quality control in digital radiographic systems is very important, even more than in conventional film-screen systems. Differences between digital and analogical images,a in terms of dynamics range, spatial and contrast resolution, and the flexibility of data post-processing require some actions to maintain clinical images in an optimum quality level. Revision 1 of the Spanish Protocol of Quality Control in Diagnostic Radiology includes a chapter dedicated to the quality control of these digital systems for the acquisition of radiographic images. In this paper the different parameters for quality control procedures are described. Also some difficulties to be concerned about (absence of levels of tolerance, access to the raw-data images and related information, availability of use anthropomorphic phantoms, etc, etc) are noted, as well as the most significant aspects of the differences in relation to the ana logical systems. (Author) 15 refs.

  8. Information management system for the control of the data of the safety and radiological protection on a national scale

    International Nuclear Information System (INIS)

    Valdes Ramos, Maryzury; Prendes Alonso, Miguel; Arnau Fernadez, Alma

    2005-01-01

    The Center for Radiation Protection and Hygiene (CPHR) and the National Center for Nuclear Safety (CNSN), have been working in the last years in the design and improvement of a computing tool that allows the management of all the important information, which should be controlled by the Regulatory Authority. The results obtained with the design and implementation of the Integrated System of Data (RASSYN) for the management of the National Regulatory Authority's information in the country are shown in this paper. The software allows an efficient management of the information related to several regulatory aspects such as: the radiation sources in the national territory; the practices associated to the sources; the personnel associated to the practices and their doses; the instruments for the measurement; the waste management; the radiological events; the conditions and requirements of the given authorizations and the inspections results

  9. Mechanical analysis of flying robot for nuclear safety and security control by radiological monitoring

    International Nuclear Information System (INIS)

    Cho, Hyo Sung; Woo, Tae Ho

    2016-01-01

    Highlights: • Radiological monitoring of the NPPs site is performed by the flying robot. • The mechanics of drone is investigated in the NPPs. • Yaw and Pitch motions are simulated for the robotic behaviors. • The flying robot is analyzed for the nuclear safety and security successfully. - Abstract: The flying robot is investigated for the nuclear accident and security treatment. Several mechanics are introduced for the movement of the drone. The optimized motion of the drone should cover all areas of Nuclear Power Plants (NPPs) over the site where the circular and surmounting motions are needed with traverse of zigzag shapes. There is the Yaw motion in the circular moving and the Pitch motion in the climbing and downing against reactor facility. The fallout is calculated from the radiation concentration in the breaking part of the NPPs where the radioactive material leaks from the containment, coolant loop, plant facility and so on. The dose equivalents are obtained where the values are changeable following the random values of the y value, average wind speed, and dispersed concentration in the detection position. The simulation of new positions of x, y, and z are normalized from 0.0 to 1.0. The mechanics of flying robot produces the multidisciplinary converged technology incorporated with the aerial radiation monitoring information.

  10. Detection and excision of non-palpable breast lesions by radio guided surgery and air injection for radiological control

    International Nuclear Information System (INIS)

    Machado, Rafael Henrique Szymanski; Gutfilen, Bianca; Fonseca, Lea Mirian Barbosa da

    2005-01-01

    Purpose: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. Methods: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with 99m Tc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. Results: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS lesions, in 31.5% (6/19) of the 4 BI-RADS and in 66.6% (2/3) of the 5 BI-RADS. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). Conclusions: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients. (author)

  11. Dental radiology

    International Nuclear Information System (INIS)

    Bhaskar, S.N.

    1982-01-01

    The book presents the radiological manifestations of the maxillodental region in a suitable manner for fast detection and correct diagnosing of diseases of the teeth, soft tissue, and jaws. Classification therefore is made according to the radiological manifestations of the diseases and not according to etiology. (orig./MG) [de

  12. Centring radiological protection on today's global challenges in energy, climate change, environment and health-with nuclear energy playing a key role

    International Nuclear Information System (INIS)

    Saint-Pierre, S.

    2011-01-01

    The climate change issue includes meeting the growing demand for electricity while reducing the impacts from energy sources. Applying carbon capture and storage technology to fossil fuel energy and increasing renewable energy pose greater challenges than increasing nuclear energy. International Energy Agency's (IEA) electricity demand of 30 000 TWh by 2030 can be met with 10 000 TWh each from renewable, nuclear and fossil fuel energy. However, the ill-imposed very strict control of tiny public exposure to ionising radiation from nuclear energy continues to pose a serious hindrance. Effort needs to be re-balanced to produce an even-handed control of public exposure with emphasis on the most significant sources (i.e. natural background radiation and medical use) and vice versa. The on-going revision of the International Atomic Energy Agency Basic Safety Standards (BSS) provides an opportunity to achieve this internationally so that national regulations can be subsequently remediated. There can be no urgency in a BSS revision that fails to encompass such perspective. (authors)

  13. Centring radiological protection on today's global challenges in energy, climate change, environment and health--with nuclear energy playing a key role.

    Science.gov (United States)

    Saint-Pierre, Sylvain

    2011-07-01

    The climate change issue includes meeting the growing demand for electricity while reducing the impacts from energy sources. Applying carbon capture and storage technology to fossil fuel energy and increasing renewable energy pose greater challenges than increasing nuclear energy. International Energy Agency's (IEA) electricity demand of 30 000 TWh by 2030 can be met with 10 000 TWh each from renewable, nuclear and fossil fuel energy. However, the ill-imposed very strict control of tiny public exposure to ionising radiation from nuclear energy continues to pose a serious hindrance. Effort needs to be re-balanced to produce an even-handed control of public exposure with emphasis on the most significant sources (i.e. natural background radiation and medical use) and vice versa. The on-going revision of the International Atomic Energy Agency Basic Safety Standards (BSS) provides an opportunity to achieve this internationally so that national regulations can be subsequently remediated. There can be no urgency in a BSS revision that fails to encompass such perspective.

  14. Radiological protection and routinary controls of an activimeter with a cesium and barium sources in an nuclear medicine center; Proteccion radiologica y controles rutinarios de un activimetro con fuentes de cesio y bario en un centro de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Morales L, M.E. [IPEN INEN, Centro de Medicina Nuclear, Av. Aviacion 3799, Lima 34 (Peru)]. e-mail: toyoco3000@hotmail.com

    2006-07-01

    In the present work the results when carrying out the routine controls in a Deluxe Isotope (Calibrator II) equipment, with some sources of Cesium 137 and Barium 133, in a Nuclear Medicine Center that operates from the year 1983 in a modern one construction inside the Institute of Neoplastic Illnesses (INEN) are shown. Taking in account the Radiological Protection measures to verify if the equipment responds to the personnel's demands in the measurements of activities of the diverse radionuclides that are used in different types of exams that are carried out in this Nuclear Medicine Center are the objectives of this work. This Center was equipped initially with donated equipment by the International Atomic Energy Agency (IAEA) with those that it develops assistance, educational works and of research, giving services to patients of the INEN and other public and private medical centers. (Author)

  15. Scrutinized with inadequate control and support: Interns' experiences communicating with and writing referrals to hospital radiology departments – A qualitative study

    International Nuclear Information System (INIS)

    Kruse, J.; Lehto, N.; Riklund, K.; Tegner, Y.; Engström, Å.

    2016-01-01

    Introduction: Interns' experiences communicating with and writing referrals to hospital radiology departments are important for patient safety, image quality, and decision-making in the diagnostic process. Understanding roles within the department and in the diagnostic process is important for communication. This study aimed to describe interns' experiences communicating with and writing referrals to their hospital's radiology department. Method: A qualitative study design was used. Data was collected from focus discussions with ten interns in three focus groups in Northern Sweden during 2012. The data were subjected to qualitative content analysis. Results: One theme, “a feeling of being scrutinized and lacking control”, was identified in the final categories. The interns experienced that the radiology department placed high demands on them and desired more diagnostic skills training, resources and feedback. The interns suggested the following improvements: enhanced dialogue and feedback, improved education, handy guidelines, and practice writing referrals. Conclusion: Interns need more feedback from, and dialogue with, members of the Department of Radiology. They also need more knowledge of referral guidelines, appropriateness criteria and more practice to develop their knowledge and skill for writing referrals. They describe feelings of inadequate support and feel scrutinized in demanding work conditions and need more collaboration. They also need more time and more control of radiology outcomes, and they are eager to learn. - Highlights: • Interns' experiences of writing referrals are important in the diagnostic process. • Communication between referents and radiology staff influences patient safety. • Medical interns experience insufficient diagnostic skills. • Interns need more feedback from, and dialogue with radiology staff. • The learning process could benefit from knowledge of the referrers perspective.

  16. Frontiers of controlling energy levels at interfaces

    Science.gov (United States)

    Koch, Norbert

    The alignment of electron energy levels at interfaces between semiconductors, dielectrics, and electrodes determines the function and efficiency of all electronic and optoelectronic devices. Reliable guidelines for predicting the level alignment for a given material combination and methods to adjust the intrinsic energy landscape are needed to enable efficient engineering approaches. These are sufficiently understood for established electronic materials, e.g., Si, but for the increasing number of emerging materials, e.g., organic and 2D semiconductors, perovskites, this is work in progress. The intrinsic level alignment and the underlying mechanisms at interfaces between organic and inorganic semiconductors are discussed first. Next, methods to alter the level alignment are introduced, which all base on proper charge density rearrangement at a heterojunction. As interface modification agents we use molecular electron acceptors and donors, as well as molecular photochromic switches that add a dynamic aspect and allow device multifunctionality. For 2D semiconductors surface transfer doping with molecular acceptors/donors transpires as viable method to locally tune the Fermi-level position in the energy gap. The fundamental electronic properties of a prototypical 1D interface between intrinsic and p-doped 2D semiconductor regions are derived from local (scanning probe) and area-averaged (photoemission) spectroscopy experiments. Future research opportunities for attaining unsurpassed interface control through charge density management are discussed.

  17. Zebra mussel control using acoustic energy

    International Nuclear Information System (INIS)

    Tiller, G.W.; Gaucher, T.A.; Menezes, J.K.; Dolat, S.W.

    1992-01-01

    A practical and economical device or method that reduces zebra mussel colonization without detrimental side effects is highly desirable. An ideal method is one that could be installed near, on, or in existing raw water intakes and conduits. It must have a known effect that is limited to a defined area, should have maximum effects on a targeted species, and preferably have a low life cycle cost than the current alternative methods of control and maintenance. Underwater sound could be such a desirable solution, if found to be an effective control measure for zebra mussels. Although sound most often applies specifically to acoustic energy that is audible to humans, 20 Hertz (Hz) to 20 kiloHertz (kHz), in this report we will use the terms sound and acoustic to include acoustic energy between 100 Hz and 100 MegaHertz (MHz). This research on zebra mussel biofouling is designed to effect the early developmental stages in the life cycle of Dreissena polymorpha (Pallas). Vulnerable stages in the development of D. polymorpha that might yield to site-specific acoustic deterrence measures include the free-swimming larval veliger stage, the postveliger pre-attachment demersal stage, and the immediate post-attachment stage. The proposed applications include surface treatment to prevent, reduce or eliminate colonization on underwater structures, and the stream treatment to reduce or eliminate (destroy) mussel larvae entrained in a moving volume of water

  18. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  19. Radiological Protection in Odontology: Analysis from the Faculty of Odontology at Rio de Janeiro concerning standards, licenses, controls and installations

    International Nuclear Information System (INIS)

    Padilha Filho, L.G.; Borgues, J.C.; Raymundo Junior, R.; Koch, H.A.

    1998-01-01

    This work shows the need and the importance training odontologists on radiological protection has. This is based on a proposal recently made by Technical Regulations: Trends for Radiological Protection in Medical and Odontological Radiodiagnosis from the Secretariat of Health Security from the Ministry of Health. These establish basic standards for radiation protection in medical and odontological areas

  20. Proceedings of the second US Department of Energy environmental control symposium. Volume 2. Nuclear energy, conservation, and solar energy

    International Nuclear Information System (INIS)

    1980-06-01

    These proceedings document the presentations given at the Second Environmental Control Symposium. Symposium presentations highlighted environmental control activities which span the entire DOE. Volume II contains papers relating to: environmental control aspects of nuclear energy use and development; nuclear waste management; renewable energy sources; transportation and building conservation (fuel economy, gasohol, building standards, and industry); and geothermal energy, power transmission, and energy storage

  1. Proceedings of the second US Department of Energy environmental control symposium. Volume 2. Nuclear energy, conservation, and solar energy

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-06-01

    These proceedings document the presentations given at the Second Environmental Control Symposium. Symposium presentations highlighted environmental control activities which span the entire DOE. Volume II contains papers relating to: environmental control aspects of nuclear energy use and development; nuclear waste management; renewable energy sources; transportation and building conservation (fuel economy, gasohol, building standards, and industry); and geothermal energy, power transmission, and energy storage. (DMC)

  2. Radiological diagnostics of muscle diseases

    International Nuclear Information System (INIS)

    Weber, M.A.; Essig, M.; Kauczor, H.U.

    2007-01-01

    Muscular diseases are a heterogeneous group of diseases with difficult differential diagnosis. This article reviews morphological and functional radiological techniques for assessment of muscular diseases. Morphological techniques can describe edema-like changes, lipomatous and atrophic changes of muscular tissue. However, these imaging signs are often not disease-specific. As a result, clinicians assign radiology a secondary role in the management of muscular diseases. Meanwhile, functional radiological techniques allow the assessment of muscle fiber architecture, skeletal muscle perfusion, myocellular sodium-homoeostasis, lipid- and energy-phosphate metabolism, etc. By detecting and spatially localizing pathophysiological phenomena, these new techniques can increase the role of radiology in muscular diseases. (orig.)

  3. The Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Hall, E.J.; Marino, S.A.

    1990-07-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) -- formerly the Radiological Research Laboratory (RRL) -- of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). Fifteen different experiments were run during these 12 months, approximately the same as the previous two years. Brief summaries of each experiment are included. Accelerator usage is summarized and development activities are discussed. 7 refs., 4 tabs

  4. Radiological optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.

    1998-01-01

    Radiological optimization is one of the basic principles in each radiation-protection system and it is a basic requirement in the safety standards for radiation protection in the European Communities. The objectives of the research, performed in this field at the Belgian Nuclear Research Centre SCK-CEN, are: (1) to implement the ALARA principles in activities with radiological consequences; (2) to develop methodologies for optimization techniques in decision-aiding; (3) to optimize radiological assessment models by validation and intercomparison; (4) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (5) to develop methods and programmes to assist decision-makers during a nuclear emergency; (6) to support the policy of radioactive waste management authorities in the field of radiation protection; (7) to investigate existing software programmes in the domain of multi criteria analysis. The main achievements for 1997 are given

  5. MEMO radiology

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.

    1989-01-01

    This radiology volume is a concise handbook of imaging techniques, nuclear medicine, and radiation therapy, albeit that the main emphasis is on classic radiology. It offers, for instance, a survey of radiological findings for the most frequent pathological conditions, many overviews of differential diagnosis, a glossary of the technical bases of radiology and so forth. The contents are divided into the following chapters: Physical and biological bases; skeleton; thorax with the subdivisions lungs, heart, mediastinum, and pleura; gastrointestinal tract with the subsections esophagus, small and large intestine; liver; biliary tract; pancreas; retroperitoneal space; kidney; suprarenal glands; bladder; blood vessels, lymph nodes, spleen; mammary glands; female genitals; prostate and scrotum, epididymis and seminal vesicle. (orig./MG) With 23 figs [de

  6. Radiological hazards

    International Nuclear Information System (INIS)

    Hamilton, M.

    1984-01-01

    The work of the (United Kingdom) National Radiological Protection Board is discussed. The following topics are mentioned: relative contributions to genetically significant doses of radiation from various sources; radon gas in non-coal mines and in dwelling houses; effects of radiation accidents; radioactive waste disposal; radiological protection of the patient in medicine; microwaves, infrared radiation and cataracts; guidance notes for use with forthcoming Ionising Radiations Regulations; training courses; personal dosimetry service; work related to European Communities. (U.K.)

  7. Development and implantation of a control and data acquisition program for the calibration of instruments for diagnostic radiology

    International Nuclear Information System (INIS)

    Betti, Flavio

    2007-01-01

    Design techniques of an automatic control system implementing corrected kerma determination and shutter command in the calibration laboratory at IPEN are shown, as well as the periodic calibration program developed for a monitor chamber for several X-ray beam qualities used for diagnostic radiology and radiation protection instruments. Two reference electrometers, a multichannel secondary standard thermometer, and an absolute pressure barometer were connected to the Rs-232 interface from a PC computer equipped with a National Instruments multi function analog and digital I/O card. LabVIEW MR was chosen as programming tool, which allowed for the development of a suite of programs for both controlling the shutter timing cycles and the calibration of the monitor chamber against a reference standard. A detailed description of the methods used for troubleshooting, fine tuning of parameters and evaluation of program results is followed by an analysis showing that considerable advantages regarding reduction of time and precision improvements during the calibrations could be achieved by the use of the developed programs, particularly under adverse conditions like those found during short expositions, or instead during long irradiation intervals where fluctuation of parameters like kerma rate or room conditions (temperature or pressure) can be found. (author)

  8. Aerial radiological survey of the United States Department of Energy's Battelle Nuclear Science Facility, West Jefferson, Ohio, date of survey: May 1977

    International Nuclear Information System (INIS)

    Feimster, E.L.

    1979-05-01

    An aerial radiological survey to measure terrestrial gamma radiation was carried out over the United States Department of Energy's Battelle Nuclear Science Facility located in West Jefferson, Ohio. Gamma ray data were collected over a 5.5 km 2 area centered on the facility by flying east-west lines spaced 61 m apart. Processed data indicated that on-site radioactivity was primarily due to radionuclides currently being processed due to the hot lab operations. Off-site data showed the radioactivity to be due to naturally occurring background radiation consistent with variations due to geologic base terrain and land use of similar areas

  9. Radiological dose assessment of Department of Energy Pinellas Plant waste proposed for disposal at Laidlaw Environmental Services of South Carolina, Inc

    International Nuclear Information System (INIS)

    Socolof, M.L.; Lee, D.W.

    1996-05-01

    The U.S. Department of Energy (DOE) Pinellas Plant in Largo, FL is proposing to ship and dispose of hazardous sludge, listed as F006 waste, to the Laidlaw Environmental Services of South Carolina, Inc. (Laidlaw) treatment, storage, and disposal facility in Pinewood, South Carolina. This sludge contains radioactive tritium in concentrations of about 28 pCi/g. The objective of this study is to assess the possible radiological impact to workers at the Laidlaw facility and members of the public due to the handling, processing, and burial of the DOE waste containing tritium

  10. Radiological dose assessment of Department of Energy Pinellas Plant waste proposed for disposal at Laidlaw Environmental Services of South Carolina, Inc.

    Energy Technology Data Exchange (ETDEWEB)

    Socolof, M.L.; Lee, D.W.

    1996-05-01

    The U.S. Department of Energy (DOE) Pinellas Plant in Largo, FL is proposing to ship and dispose of hazardous sludge, listed as F006 waste, to the Laidlaw Environmental Services of South Carolina, Inc. (Laidlaw) treatment, storage, and disposal facility in Pinewood, South Carolina. This sludge contains radioactive tritium in concentrations of about 28 pCi/g. The objective of this study is to assess the possible radiological impact to workers at the Laidlaw facility and members of the public due to the handling, processing, and burial of the DOE waste containing tritium.

  11. Aerial radiological survey of the United States Department of Energy's Pantex Plant and surrounding area Amarillo, Texas. Date of survey: October 1979

    International Nuclear Information System (INIS)

    Boyns, P.K.

    1981-07-01

    An aerial radiological survey was conducted over the United States Department of Energy's Pantex Plant and Pantex Lake areas in October, 1979. The Pantex Plant survey covered an area of approximately 64 km 2 . The Pantex Lake survey area was approximately 2 km 2 . Both areas were surveyed at an altitude of 46 m (150 feet) with lines spaced at 91 m (300 foot) intervals. Several passes were also made over the shipping areas at the Amarillo International Airport. An array of sodium iodide detectors were mounted in a helicopter to collect gamma ray spectral data. As expected, the spectral data indicated the presence of several areas containing man-made sources

  12. Monte Carlo simulation of the interaction of X-ray spectrum with human tissue, in the energies range of diagnostic radiology

    International Nuclear Information System (INIS)

    Cayllahua Q, L. F.; Apaza V, G.; Vega R, J. L.

    2015-10-01

    Full text: This paper is an approach to an increasingly complete knowledge about the nature of the processes that occur during a simple examination of radiological diagnosis; know as X-rays are produced and how they will put their energy into the tissue of patients when they are subjected to an examination of radiological diagnosis. First, using the MCNP code an X-rays tube was simulated, where electrons are emitted from a filament (cathode) which travel a certain distance with a certain kinetic energy and then be stopped suddenly in the tungsten target. The X-rays emitted as a result of this interaction, are previously filtered through the inherent filter of Pyrex glass and then by a thin aluminum foil before quantification as an X-rays spectrum. 6 spectra (for 60, 80, 100, 120 and 140 KeV) were obtained. Second, using the Penelope code was simulated the interaction of the X-rays spectrum, obtained in the first part with human tissue, putting as simile of human tissue water phantoms of different thicknesses. As final result: dose of energy deposited (in 2 and 3-dimensional) and reflected, absorbed and transmitted photons spectra. (Author)

  13. Radiological Work Planning and Procedures

    CERN Document Server

    Kurtz, J E

    2000-01-01

    Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In add...

  14. Proposed general amendments to the atomic energy control regulations

    International Nuclear Information System (INIS)

    1986-01-01

    Canada's Atomic Energy Control Act defines the powers and responsibilities of the Atomic Energy Control Board (AECB). Among these is to make regulations to control the development, application and use of atomic energy. In these proposed general amendments to the Atomic Energy Control Regulations substantial changes are proposed in the designation of the authority of AECB staff, exemptions from licensing, international safeguards, duties of licensees and atomic radiation workers, security of information, and provision for hearings. The scope of the control of atomic energy has been redefined as relating to matters of health, safety, security, international safeguards, and the protection of the environment

  15. A closed-loop energy price controlling method for real-time energy balancing in a smart grid energy market

    International Nuclear Information System (INIS)

    Alagoz, B. Baykant; Kaygusuz, Asim; Akcin, Murat; Alagoz, Serkan

    2013-01-01

    Future smart grids will require a flexible, observable, and controllable network for reliable and efficient energy delivery under uncertain generation and demand conditions. One of the mechanisms for efficient and reliable energy generation is dynamic demand-responsive generation management based on energy price adjustments that creates a balance in energy markets. This study presents a closed-loop PID (proportional–integral–derivative) controller-based price control method for autonomous and real-time balancing of energy demand and generation in smart grid electricity markets. The PID control system can regulate energy prices online to respond dynamically and instantaneously to the varying energy demands of grid consumers. Independent energy suppliers in the smart grid decide whether to sell their energy to the grid according to the energy prices declared by the closed-loop PID controller system. Energy market simulations demonstrate that PID-controlled energy price regulation can effectively maintain an energy balance for hourly demand fluctuations of consumers. - Highlights: • This study presents a control theoretic approach for management of energy balance. • A closed-loop PID controller-based price controlling method is used in smart grid. • The simulation results demonstrate advantages of PID-based energy price control. • This method is appropriate for demand responsive management of smart grid markets

  16. Westinghouse radiological containment guide

    International Nuclear Information System (INIS)

    Aitken, S.B.; Brown, R.L.; Cantrell, J.R.; Wilcox, D.P.

    1994-03-01

    This document provides uniform guidance for Westinghouse contractors on the implementation of radiological containments. This document reflects standard industry practices and is provided as a guide. The guidance presented herein is consistent with the requirements of the DOE Radiological Control Manual (DOE N 5480.6). This guidance should further serve to enable and encourage the use of containments for contamination control and to accomplish the following: Minimize personnel contamination; Prevent the spread of contamination; Minimize the required use of protective clothing and personal protective equipment; Minimize the generation of waste

  17. Westinghouse radiological containment guide

    Energy Technology Data Exchange (ETDEWEB)

    Aitken, S.B. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Brown, R.L. [Westinghouse Hanford Co., Richland, WA (United States); Cantrell, J.R. [Westinghouse Savannah River Co., Aiken, SC (United States); Wilcox, D.P. [West Valley Nuclear Services Co., Inc., West Valley, NY (United States)

    1994-03-01

    This document provides uniform guidance for Westinghouse contractors on the implementation of radiological containments. This document reflects standard industry practices and is provided as a guide. The guidance presented herein is consistent with the requirements of the DOE Radiological Control Manual (DOE N 5480.6). This guidance should further serve to enable and encourage the use of containments for contamination control and to accomplish the following: Minimize personnel contamination; Prevent the spread of contamination; Minimize the required use of protective clothing and personal protective equipment; Minimize the generation of waste.

  18. Swinging control of two-pendulum system under energy constraints

    NARCIS (Netherlands)

    Ananyevskiy, M.S.; Fradkov, A.L.; Nijmeijer, H.; Leonov, G.; Nijmeijer, H.; Pogromsky, A.; Fradkov, A.

    2009-01-01

    A method for control of mechanical systems under phase constraints, applicable to energy control of Hamiltonian systems is proposed. The constrained energy control problem for two pendulums by a single control action is studied both analytically and numerically. It is shown that for a proper choice

  19. Advanced Neutron Source radiological design criteria

    International Nuclear Information System (INIS)

    Westbrook, J.L.

    1995-08-01

    The operation of the proposed Advanced Neutron Source (ANS) facility will present a variety of radiological protection problems. Because it is desired to design and operate the ANS according to the applicable licensing standards of the Nuclear Regulatory Commission (NRC), it must be demonstrated that the ANS radiological design basis is consistent not only with state and Department of Energy (DOE) and other usual federal regulations, but also, so far as is practicable, with NRC regulations and with recommendations of such organizations as the Institute of Nuclear Power Operations (INPO) and the Electric Power Research Institute (EPRI). Also, the ANS radiological design basis is in general to be consistent with the recommendations of authoritative professional and scientific organizations, specifically the National Council on Radiation Protection and Measurements (NCRP) and the International Commission on Radiological Protection (ICRP). As regards radiological protection, the principal goals of DOE regulations and guidance are to keep occupational doses ALARA [as low as (is) reasonably achievable], given the current state of technology, costs, and operations requirements; to control and monitor contained and released radioactivity during normal operation to keep public doses and releases to the environment ALARA; and to limit doses to workers and the public during accident conditions. Meeting these general design objectives requires that principles of dose reduction and of radioactivity control by employed in the design, operation, modification, and decommissioning of the ANS. The purpose of this document is to provide basic radiological criteria for incorporating these principles into the design of the ANS. Operations, modification, and decommissioning will be covered only as they are affected by design

  20. Radiological protection Program of CDTN

    International Nuclear Information System (INIS)

    1983-01-01

    Radiological protection program of CDTN, its purposes and rules, responsabilities, physical control, monitoring, personnel radiation protection, radiation sources and radioactive wastes control, emergency and accidents and siting are described. (C.M.) [pt

  1. Quality control to the service of diagnostic radiology in policlinics and hospitals of Santiago de Cuba

    International Nuclear Information System (INIS)

    Grinnan Torres, Reinaldo; Parra Caboberde, Hector; Semanat Sanchez, Lino A.

    2002-01-01

    The work presents the results obtained in the Quality Control in diagnostic X-ray equipment accomplished in 33 clinics of Santiago de Cuba city. The performed test were, to the X-ray generator, X-ray tube, devices collimation and alignment, as well as to the light boxes, dark rooms, and radiographic screen-film combinations. Moreover the work presents the results of the Entrance Doses for a reference patient in radiographic projections of frequent use in clinics of Santiago de Cuba city (chest, lumbar spine, abdomen, and pelvis). For the evaluation of the verified technical parameters were used the tolerance criterions recommended by the Technical Guide elaborated by the State Control Centre of Medical of Cuba. In the case of the Entrance Dose were used the dose levels that recommended by the International Basic Safety Standards for protection against ionizing radiation and for safety of radiation sources

  2. Comparison of bar pattern and edge method for MTF measurement in radiology quality control

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, M.; Alves, A.F.F; Bacchim Neto, F.A.; Pavan, A.L.M.; Rosa, M.E.D.; Miranda, J.R.A.; Pina, D.R. de, E-mail: drpina@fmb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2015-08-15

    Spatial resolution is one of the parameters that is routinely checked during acceptance procedures and regular quality control measurements. The spatial resolution of a radiographic imaging device is most appropriately expressed in terms of its modulation transfer function (MTF), which indicates the decline of detector spatial resolution with spatial frequency. Traditionally used methods of MTF measurement involve imaging either a narrow slit or a sharp edge to obtain the detector line spread function (LSF), whose frequency transform leads to the MTF. In this work is presented a study of the measurement of the limiting spatial resolution using the MTF method and the line-pair bar-pattern method. Our aim is to compare the bar-pattern method with the MTF method and then evaluate what method is the best for the dairy quality control tests and when is better to perform one test or other. These acquisition procedures were tested according to its reproducibility and variation due to noise. (author)

  3. Quality control of the interpretation monitors of digital radiological images; Controle de qualidade dos monitores de interpretacao de imagens radiologicas digitais: uma revisao

    Energy Technology Data Exchange (ETDEWEB)

    Favero, Mariana S.; Goulart, Adriano Oliveira S., E-mail: mariana@phymed.com.br [PhyMED - Consultores em Fisica Medica e Radioprotecao Ltda, Porto Alegre, RS (Brazil)

    2016-07-01

    The performance monitors has great importance in image quality of digital radiographic systems. In environments without films, it became necessary to implement acceptance testing and quality control monitors used for interpretation of medical images. The monitors dedicated to radiodiagnostic should provide information that represent slight differences in x-ray attenuation or minor differences in some anatomical region of interest. This should also result in small differences in luminance of an image represented. Factors affecting the quality of medical imaging are contrast, noise, resolution, artifacts and distortions. Therefore, a monitor must have specific characteristics, making it possible for the observer to carry out an assessment that leads to better diagnosis. Based on the need to evaluate diagnostic monitors in various radiological applications, this paper presents a summary for implementation and standardization of tests that are recommended by the publication AAPM Report 03. (author)

  4. Educational course in emergency radiology

    International Nuclear Information System (INIS)

    Velkova, K.; Stoeva, M.; Cvetkova, S.; Hilendarov, A.; Petrova, A.; Stefanov, P.; Simova, E.; Georgieva, V.; Sirakov, N.

    2012-01-01

    Emergency radiology is the part of radiology primarily focused on acute diagnosing conditions in ER patients. This advanced area of radiology improves the quality of care and treatment of patients and of the emergency medicine as a whole. The educational course in Emergency (ER) Radiology is available for medical students in their 8th and 9th semester. The main objective of the ER course is to obtain knowledge about the indications, possibilities and diagnostic value of the contemporary imaging methods in ER cases. Therapeutic methods under imaging control are also covered by the course. The curriculum of the course consists of 6 lectures and 12 practical classes. (authors)

  5. A preliminary study into performing routine tube output and automatic exposure control quality assurance using radiology information system data

    International Nuclear Information System (INIS)

    Charnock, P.; Jones, R.; Fazakerley, J.; Wilde, R.; Dunn, A. F.

    2011-01-01

    Data are currently being collected from hospital radiology information systems in the North West of the UK for the purposes of both clinical audit and patient dose audit. Could these data also be used to satisfy quality assurance (QA) requirements according to UK guidance? From 2008 to 2009, 731 653 records were submitted from 8 hospitals from the North West England. For automatic exposure control QA, the protocol from Inst. of Physics and Engineering in Medicine (IPEM) report 91 recommends that milli amperes per second can be monitored for repeatability and reproducibility using a suitable phantom, at 70-81 kV. Abdomen AP and chest PA examinations were analysed to find the most common kilo voltage used with these records then used to plot average monthly milli amperes per second with time. IPEM report 91 also recommends that a range of commonly used clinical settings is used to check output reproducibility and repeatability. For each tube, the dose area product values were plotted over time for two most common exposure factor sets. Results show that it is possible to do performance checks of AEC systems; however more work is required to be able to monitor tube output performance. Procedurally, the management system requires work and the benefits to the workflow would need to be demonstrated. (authors)

  6. Radiological Assistance Program (RAP) Regions

    Data.gov (United States)

    Department of Homeland Security — The U.S. Department of Energy (DOE) created the Radiological Assistance Program (RAP) in the 1950s to make DOE resources and expertise available to organizations...

  7. Radiological protection

    International Nuclear Information System (INIS)

    Azorin N, J.; Azorin V, J. C.

    2010-01-01

    This work is directed to all those people related with the exercise of the radiological protection and has the purpose of providing them a base of knowledge in this discipline so that they can make decisions documented on technical and scientist factors for the protection of the personnel occupationally exposed, the people in general and the environment during the work with ionizing radiations. Before de lack of a text on this matter, this work seeks to cover the specific necessities of our country, providing a solid presentation of the radiological protection, included the bases of the radiations physics, the detection and radiation dosimetry, the radiobiology, the normative and operational procedures associates, the radioactive wastes, the emergencies and the transport of the radioactive material through the medical and industrial applications of the radiations, making emphasis in the relative particular aspects to the radiological protection in Mexico. The book have 16 chapters and with the purpose of supplementing the given information, are included at the end four appendixes: 1) the radioactive waste management in Mexico, 2-3) the Mexican official standards related with the radiological protection, 4) a terms glossary used in radiological protection. We hope this book will be of utility for those people that work in the investigation and the applications of the ionizing radiations. (Author)

  8. Radiological control for 203Hg radiotracer determinations of mercury inventories at chlor-alkali plants.

    Science.gov (United States)

    Martin, J E; Lee, C

    2001-11-01

    20Hg has been used safely to determine mercury inventories in large electrochemical process cells in the chlorine industry by a process of isotopic dilution. Laboratory conversion and processing of irradiated HgO can be done in closed systems with non-detectable releases to work areas or the environment and with exposure to whole body <0.25 mSv (25 mrem) and <3 mSv (300 mrem) to extremities. Personnel exposures during plant operations are controlled to non-detectable levels for whole body exposure and <0.3 mSv (30 mrem) to extremities for the operator; exposures for other plant personnel are non-detectable.

  9. Radiological impacts from nuclear facilities on non-human species

    International Nuclear Information System (INIS)

    1997-07-01

    This monograph is the Proceedings of a Symposium on Radiological Impacts from Nuclear Facilities on Non-Human Species, held in Ottawa, Canada, December 1 and 2, 1996. The Symposium was held in response to the assessment of radiological impacts from nuclear facilities on non-human biota by Environment Canada and the move by Atomic Energy Control Board to include the radiological impacts in its regulatory regime. The two major goals of the Symposium were to critically evaluate the ecological risk assessment as applied to radionuclides and contribute to the wide consultation sought by the Atomic Energy Control Board on their new environmental initiatives. The series of papers presented at the Symposium discuss issues relevant to the two major objectives of the Symposium

  10. A successful waste stream analysis on a large construction project in a radiologically controlled area

    International Nuclear Information System (INIS)

    Kennicott, M.; Richardson, D.; Starke, T.P.

    1997-01-01

    The Los Alamos National Laboratory (the Laboratory) Chemistry and Metallurgy Research (CMR) Facility, constructed in 1952, is currently under going a major, multi-year demolition and construction project. Many of the operations required under this project (i.e., design, demolition, decontamination, construction, and waste management) mimic the processes required of a large scale decontamination and decommissioning (D and D) job and are identical to the requirements of any of several upgrades projects anticipated for the laboratory and other Department of Energy (DOE) sites. For these reasons the CMR upgrades Project is seen as an ideal model facility--to test the application and measure the success of waste minimization techniques which could be implemented for any similar projects. The purpose of this paper will be to discuss the successful completion of a waste stream analysis. The analyses performed was to measure the potential impact of waste generation, in terms of volume and costs, for a reconfiguration option being considered to change the approach and execution of the original project

  11. Utilization of water soluble plastics for radiological control within nuclear power plants

    International Nuclear Information System (INIS)

    Smith, R.J.; Deltete, C.P.; Homyk, W.A.; Kasprzak, L.; Robinson, P.J.

    1989-01-01

    The utilization of plastic products for radioactive contamination control within nuclear power facilities currently results in relatively large volumes of waste requiring disposal as low-level radioactive waste. The utilization of a polymer resin product that possesses comparable physical attributes to currently utilized plastic materials, but which is water soluble, has significant potential to reduce the volume of plastic waste requiring disposal as radwaste. Such a volume reduction will reduce overall plant )ampersand M costs, reduce the overall waste volume allocation utilization, and improve the regulatory perception of any plant realizing a volume reduction through plastic source minimization. This potential reduction in waste volume (and associated availability of the Low-level Waste Policy Amendments Act disposal allocation for other purposes), combined with potential economic benefits summarized above, has led to the undertaking of a detailed evaluation, presented in this paper

  12. Radiological assessment of placement of the hysteroscopically inserted Essure permanent birth control device.

    Science.gov (United States)

    Lorente Ramos, R M; Azpeitia Armán, J; Aparicio Rodríguez-Miñón, P; Salazar Arquero, F J; Albillos Merino, J C

    2015-01-01

    Essure is a permanent birth control device that is inserted through the cervix by hysteroscopy. The device is placed in the fallopian tubes, where it causes occlusion by stimulating fibrosis. Patients can be followed up with plain-film X-rays, hysterosalpingography, and ultrasonography, although the devices can also be identified incidentally on CT and MRI. The follow-up of Essure is based on checking the criteria for appropriate positioning and correct functioning (tubal occlusion) and on diagnosing complications. The most common complications are perforation, migration (toward the uterine or peritoneal cavity), and occlusion failure. In hysterosalpingography, vascular intravasation is the most common cause of diagnostic error. Radiologists need to know how to recognize the device on different imaging techniques, how to check that it is correctly placed and functioning, and how to diagnose complications. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  13. The evolution of legal approaches to controlling nuclear and radiological weapons and combating the threat of nuclear terrorism

    NARCIS (Netherlands)

    Herbach, J.

    2015-01-01

    This chapter traces the evolution of international law related to the weaponization of nuclear and other radioactive materials, focusing in particular on the law pertaining to preventing acts of nuclear terrorism. International efforts to control atomic energy have evolved substantially since the

  14. Radionuclide radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.; Bradley, K.M.

    2006-01-01

    This is the fourth in a series of short reviews of internet-based radiological educational resources, and will focus on radionuclide radiology and nuclear medicine. What follows is a list of carefully selected websites to save time in searching them out. Most of the sites cater for trainee or non-specialist radiologists, but may also be of interest to specialists for use in teaching. This article may be particularly useful to radiologists interested in the rapidly expanding field of positron emission tomography computed tomography (PET-CT). Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (February 2006)

  15. Emergency radiology

    International Nuclear Information System (INIS)

    Keats, T.E.

    1986-01-01

    This book is the German, translated version of the original published in 1984 in the U.S.A., entitled 'Emergency Radiology'. The publication for the most part is made up as an atlas of the radiological images presenting the findings required for assessment of the emergency cases and their first treatment. The test parts' function is to explain the images and give the necessary information. The material is arranged in seven sections dealing with the skull, the facial part of the skull, the spine, thorax, abdominal region, the pelvis and the hip, and the limbs. With 690 figs [de

  16. Postoperative radiology

    International Nuclear Information System (INIS)

    Burhenne, H.J.

    1989-01-01

    This paper reports on the importance of postoperative radiology. Most surgical procedures on the alimentary tract are successful, but postoperative complications remain a common occurrence. The radiologist must be familiar with a large variety of possible surgical complications, because it is this specialty that is most commonly called on to render a definitive diagnosis. The decision for reoperation, for instance, is usually based on results from radiologic imaging techniques. These now include ultrasonography, CT scanning, needle biopsy, and interventional techniques in addition to contrast studies and nuclear medicine investigation

  17. Energy: Systems for Control, Maintenance, and Storage. A Bibliography.

    Science.gov (United States)

    Thomas, Gerald, Comp.; McKane, Irving, Comp.

    This publication is a bibliography of available periodical literature on specific aspects of energy and today's technology. The Applied Science and Technology Indexes were searched for articles that related to these specific areas: (1) Energy control systems; (2) Maintenance of Energy Systems; and (3) Energy storage. The articles and papers…

  18. Long-term radiological liabilities and institutional control for radiation hazardous objects in the Russian Federation

    International Nuclear Information System (INIS)

    Iskra, A.; Lebedev, O.; Popov, V.

    2006-01-01

    Efforts aimed at securing safe human life environment are taking more and more significant place in the RF public policy sphere, practical steps are being made for the purpose of environmental remediation, including scheduled life cycle completion of a number of nuclear- and radiation-hazardous engineering objects. Currently nuclear subs decommissioning and dismantling is being carried out, as well as decommissioning of research reactors in various cities of the country. A number of industrial sites have already been cleaned up, in some places restoration works are on, remediation of the reactor sites and former naval technical service bases is being planned. Whereas nuclear reactors for various purposes, spent nuclear fuel and radwaste storage facilities, have safe and reliable physical protection, trained personnel and arm guard, so that the risk of the objects' eventual effects on the natural environment and the population in adjacent areas is well predicted at any stage of their life cycle, be it regular operation, shutdown, dismantling or site remediation, such components of the radiation legacy as radioactively contaminated sites and radionuclide ionizing radiation sources, though so different by nature, but equally bearing radiation threat, cause well explainable public anxiety. Their specific character lies not only in the fact that they are often not guarded in a proper way, but also in the great extent to which they are spread geographically. In order to prevent non-sanctioned access to such kind of objects and eventual exposure of the population, an institutional control system (ICS) should be set up for the radiation risk sources. The ICS has very much in common for various types of the radiation hazardous objects, and it should include such constituents as regulatory and normative documentation, environmental (radiation inclusive) monitoring arrangement, radioactive materials and radioactive wastes control and accounting, ensuring of civil security

  19. Control Methods Utilizing Energy Optimizing Schemes in Refrigeration Systems

    DEFF Research Database (Denmark)

    Larsen, L.S; Thybo, C.; Stoustrup, Jakob

    2003-01-01

    The potential energy savings in refrigeration systems using energy optimal control has been proved to be substantial. This however requires an intelligent control that drives the refrigeration systems towards the energy optimal state. This paper proposes an approach for a control, which drives th...... the condenser pressure towards an optimal state. The objective of this is to present a feasible method that can be used for energy optimizing control. A simulation model of a simple refrigeration system will be used as basis for testing the control method....

  20. Aerial radiological survey of the United States Department of Energy's Sandia National Laboratories and Inhalation Toxicology Research Institute, Albuquerque, New Mexico. Date of survey: April 1981

    International Nuclear Information System (INIS)

    Boyns, P.K.

    1982-05-01

    An aerial radiological survey of the Sandia National Laboratories (SNLA) and the Inhalation Toxicology Research Institute (ITRI) was carried out in April 1981 by EG and G, Inc. for the United States Department of Energy. The survey consisted of an airborne measurement of both natural and man-made gamma radiation from the terrain surface in and around the SNLA and ITRI site. These measurements allowed a determination of the surface terrestrial spatial distribution of isotope concentrations. Results are reported as exposure rates and man-made isopleths and are superimposed on 240 m/cm scale map of the area. Gamma ray energy spectra are also presented for the net man-made radioelements. Several areas of man-made activity were detected in the SNLA and ITRI survey. These areas were associated with normal operations at the SNLA, ITRI and Kirtland Air Force Base. The presence of 241 Am was not detected in any of the areas surveyed

  1. Aerial radiological survey of US Department of Energy sites in Ames, Iowa. Date of survey: May 1977

    International Nuclear Information System (INIS)

    1979-07-01

    An aerial radiological survey to measure terrestrial gamma radiation was carried out over five areas totaling 10 km 2 within the town of Ames, Iowa. Gamma ray data were measured over Ames Laboratory, several sections of downtown Ames, and the surrounding area. This was accomplished by flying parallel east-west lines 61 m apart. Processed data indicated that three areas showed increased activity levels of at least twice average background: the reactor, the waste treatment area, and a small area near the airport runway

  2. Hypothalamic control of energy and glucose metabolism.

    Science.gov (United States)

    Sisley, Stephanie; Sandoval, Darleen

    2011-09-01

    The central nervous system (CNS), generally accepted to regulate energy homeostasis, has been implicated in the metabolic perturbations that either cause or are associated with obesity. Normally, the CNS receives hormonal, metabolic, and neuronal input to assure adequate energy levels and maintain stable energy homeostasis. Recent evidence also supports that the CNS uses these same inputs to regulate glucose homeostasis and this aspect of CNS regulation also becomes impaired in the face of dietary-induced obesity. This review focuses on the literature surrounding hypothalamic regulation of energy and glucose homeostasis and discusses how dysregulation of this system may contribute to obesity and T2DM.

  3. Enhanced radiological work planning; TOPICAL

    International Nuclear Information System (INIS)

    DECKER, W.A.

    1999-01-01

    The purpose of this standard is to provide Project Hanford Management Contractors (PHMC) with guidance for ensuring radiological considerations are adequately addressed throughout the work planning process. Incorporating radiological controls in the planning process is a requirement of the Hanford Site Radiological Control Manual (HSRCM-I), Chapter 3, Part 1. This standard is applicable to all PHMC contractors and subcontractors. The essential elements of this standard will be incorporated into the appropriate site level work control standard upon implementation of the anticipated revision of the PHMC Administration and Procedure System

  4. SA Journal of Radiology

    African Journals Online (AJOL)

    Radiology examination as a diagnostic aid in presentations with wide differential diagnoses: Case report of new Hodgkin's lymphoma on a background of poorly controlled HIV · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Rachel Hubbard, Jalpa Kotecha, Thomas ...

  5. Radiological safety by design

    International Nuclear Information System (INIS)

    Gundaker, W.E.

    1977-01-01

    Under the Radiation Control for Health and Safety Act enacted by the U.S. Congress in 1968, the Food and Drug Administration's Bureau of Radiological Health may prescribe performance standards for products that emit radiation. A description is given of the development of these standards and outlines the administrative procedures by which they are enforced. (author)

  6. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  7. Anesthesia for interventional radiology

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; Casola, G.; Varney, R.R.; D'Agostino, H.B.; Zornow, M.; Mazzie, W.

    1989-01-01

    We recognized that the complexity and surgical nature of many interventional radiology procedures dictate essential radiologic involvement into traditional anesthesiologic areas. They reviewed our experience with a variety of interventional procedures to document complications and problems related to anesthetic use (or misuse) and compile recommendations for rational monitoring and control for these procedures. In particular, the authors have studied complications of drug therapies and the treatment of these complications; use of complex anesthesia procedures (e.g., epidural anesthesia, succinylcholine blockage); reasons for choice of drugs (e.g., fentanyl vs meperidine vs morphine); and medico-legal aspects of radiologist performing traditional anesthesiology-type procedures

  8. Instrumentation and control for fossil-energy processes

    Energy Technology Data Exchange (ETDEWEB)

    1982-09-01

    The 1982 symposium on instrumentation and control for fossil energy processes was held June 7 through 9, 1982, at Adam's Mark Hotel, Houston, Texas. It was sponsored by the US Department of Energy, Office of Fossil Energy; Argonne National Laboratory; and the Society for Control and Instrumentation of Energy Processes. Fifty-two papers have been entered individually into EDB and ERA; eleven papers had been entered previously from other sources. (LTN)

  9. Pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, G.

    1997-01-01

    Pediatric radiology is an important subsection of diagnostic radiology involving specific difficulties, but unfortunately is quite too often neglected as a subject of further education and training. The book therefore is not intended for specialists in the field, but for radiologists wishing to plunge deeper into the matter of pediatric radiology and to acquire a sound, basic knowledge and information about well-proven modalities, the resulting diagnostic images, and interpretation of results. The book is a compact guide and a helpful source of reference and information required for every-day work, or in special cases. With patients who are babies or children, the challenges are different. The book offers all the information needed, including important experience from pediatric hospital units that may be helpful in diagnostic evaluation, information about specific dissimilarities in anatomy and physiology which affect the imaging results, hints for radiology planning and performance, as well as information about the various techniques and their indication and achievements. The book presents a wide spectrum of informative and annotated images. (orig./CB) [de

  10. Radiologic considerations

    International Nuclear Information System (INIS)

    Judge, L.O.

    1987-01-01

    An increasing variety of imaging modalities as well as refinements of interventional techniques have led to a resurgence of radiologic interest and participation in urolithiasis management. Judicious selection of the diagnostic examination, close monitoring during the procedure, consultation with urologic colleagues, and a careful regard for radiation safety guidelines define the role of the radiologist in renal stone disease

  11. Intelligent energy efficiency control in hospitals

    Energy Technology Data Exchange (ETDEWEB)

    Nykaenen, E., Email: esa.nykanen@vtt.fi

    2012-06-15

    The concern of European society for the well-being of its residents and the sustainability of the environment has led to the consciousness that energy savings need to be at the top of the political agenda. Until recently, the focus of energy reduction has been on schools and offices. Hospitals, however, also use large amounts of energy. Therefore, the project will address specifically the hospital domain. HosPilot will address the two main technology areas Lighting and HVAC (Heating, Ventilation and Air Conditioning), thus covering the largest part of the energy-consuming areas. By adding intelligence, ICT (Information and Communication Technology) will play a vital role to achieve significant energy reduction in the complex environment of a hospital. (orig.)

  12. Dynamic modeling, simulation and control of energy generation

    CERN Document Server

    Vepa, Ranjan

    2013-01-01

    This book addresses the core issues involved in the dynamic modeling, simulation and control of a selection of energy systems such as gas turbines, wind turbines, fuel cells and batteries. The principles of modeling and control could be applied to other non-convention methods of energy generation such as solar energy and wave energy.A central feature of Dynamic Modeling, Simulation and Control of Energy Generation is that it brings together diverse topics in thermodynamics, fluid mechanics, heat transfer, electro-chemistry, electrical networks and electrical machines and focuses on their appli

  13. Noise-control needs in the developing energy technologies

    Energy Technology Data Exchange (ETDEWEB)

    Keast, D.N.

    1978-03-01

    The noise characteristics of existing energy conversion technologies, e.g., from obtaining and processing fossil fuels to power plants operations, and of developing energy technologies (wind, geothermal sources, solar energy or fusion systems) are discussed in terms of the effects of noise on humans, animals, structures, and equipment and methods for noise control. Regulations for noise control are described. Recommendations are made for further research on noise control and noise effects. (LCL)

  14. Radiological information systems: improvements in service, economy, and quality control?; Radiologische Informationssysteme: Verbesserung von Leistungserfassung, Wirtschaftlichkeit und Qualitaetssicherung?

    Energy Technology Data Exchange (ETDEWEB)

    Gross-Fengels, W. [Abt. fuer Klinische Radiologie, AK Harburg (Germany); Weber, M. [Abt. fuer Klinische Radiologie, AK Harburg (Germany)

    1997-03-01

    By means of complete service control and standardized accounting processes, radiological information systems clearly contribute to improved results. They provide the prerequisites for the establishment of expanded networks and allow comprisons with comparable institutions. The quality of patient care can be improved since, for example, the production time from referral to finished result becomes shorter. Direct access to patient and findings data from several positions is possible. Preliminary results can be viewed immediately. The patient`s history is accessible to authorized users at all times. The exact reproducibility and assignment of services leads to more clarity. By means of the information available form RIS, rapid adaptive processes can be undertaken. The system assists the to fulfill the requirements of health regulations. The above-mentioned relationships demonstrate that the EDP systems are well accepted by physicians, medical assistants, and administrators and represent an indispensable aid for solving problems. (orig.) [Deutsch] Radiologische Informationssysteme fuehren ueber komplette Leistungserfassungen und standardisierte Abrechnungsverfahren eindeutig zu einer Ergebnisverbesserung. Sie stellen die Voraussetzungen fuer den Aufbau erweiterter Netzstrukturen dar und erlauben Quervergleiche mit aehnlichen Institutionen. Die Qualitaet der Patientenversorgung laesst sich verbessern, da z.B. die `Produktionszeit` von der Anforderung bis hin zur Befundausgabe kuerzer wird. Der Zugriff zu Patienten- und Befunddaten ist unmittelbar von mehreren Stellen aus moeglich. Vorbefunde sind sofort einsehbar. Die Patientenhistorie ist jederzeit fuer autorisierte Anwender verfuegbar. Die exakte Reproduzierbarkeit und Zuordnung der Leistungen fuehrt zu einer hohen Transparenz. Durch die Informationen, die ueber das RIS zu erhalten sind, koennen rasche Anpassungsprozesse vorgenommen werden. Die Anlagen unterstuetzen den Anwender, den Anforderungen der GSG nachzukommen

  15. Atomic Energy Control Act, c A.19, s.1

    International Nuclear Information System (INIS)

    1985-01-01

    The Revised Statutes of Canada 1985 entered into force on 12 December 1988, revoking the previous Atomic Energy Control Act and replacing it with a new version. The new Act (Chapter A-16 of the Revised Statutes) updates the previous text and makes some linguistic corrections. The Atomic Energy Control Act establishes the Atomic Energy Control Board and sets out its duties and powers which include, in particular, the making of regulations for developing, controlling and licensing the production, application and use of atomic energy [fr

  16. Neuropeptides controlling energy balance: orexins and neuromedins

    Science.gov (United States)

    Nixon, Joshua P.; Kotz, Catherine M.; Novak, Colleen M.; Billington, Charles J.; Teske, Jennifer A.

    2016-01-01

    In this section we review the feeding and energy expenditure effects of orexin (also known as hypocretin) and neuromedin. Orexins are multifunctional neuropeptides that affect energy balance by participating in regulation of appetite, arousal, and spontaneous physical activity. Central orexin signaling for all functions originates in the lateral hypothalamus–perifornical area, and is likely functionally differentiated based on site of action and on interacting neural influences. The effect of orexin on feeding is likely related to arousal in some ways, but is nonetheless a separate neural process that depends on interactions with other feeding related neuropeptides. In a pattern distinct from other neuropeptides, orexin stimulates both feeding and energy expenditure. Orexin increases in energy expenditure are mainly by increasing spontaneous physical activity, and this energy expenditure effect is more potent than the effect on feeding. Global orexin manipulations, such as in transgenic models, produce energy balance changes consistent with a dominant energy expenditure effect of orexin. Neuromedins are gut-brain peptides that reduce appetite. There are gut sources of neuromedin, but likely the key appetite related neuromedin producing neurons are in hypothalamus and parallel other key anorectic neuropeptide expression in the arcuate to paraventricular hypothalamic projection. As with other hypothalamic feeding related peptides, hindbrain sites are likely also important sources and targets of neuromedin anorectic action. Neuromedin increases physical activity in addition to reducing appetite, thus producing a consistent negative energy balance effect. Together with the various other neuro-peptides, -transmitters, -modulators and –hormones, neuromedin and orexin act in the appetite network to produce changes in food intake and energy expenditure, which ultimately influences the regulation of body weight. PMID:22249811

  17. Electrical appliance energy consumption control methods and electrical energy consumption systems

    Science.gov (United States)

    Donnelly, Matthew K [Kennewick, WA; Chassin, David P [Pasco, WA; Dagle, Jeffery E [Richland, WA; Kintner-Meyer, Michael [Richland, WA; Winiarski, David W [Kennewick, WA; Pratt, Robert G [Kennewick, WA; Boberly-Bartis, Anne Marie [Alexandria, VA

    2006-03-07

    Electrical appliance energy consumption control methods and electrical energy consumption systems are described. In one aspect, an electrical appliance energy consumption control method includes providing an electrical appliance coupled with a power distribution system, receiving electrical energy within the appliance from the power distribution system, consuming the received electrical energy using a plurality of loads of the appliance, monitoring electrical energy of the power distribution system, and adjusting an amount of consumption of the received electrical energy via one of the loads of the appliance from an initial level of consumption to an other level of consumption different than the initial level of consumption responsive to the monitoring.

  18. Electrical appliance energy consumption control methods and electrical energy consumption systems

    Science.gov (United States)

    Donnelly, Matthew K [Kennewick, WA; Chassin, David P [Pasco, WA; Dagle, Jeffery E [Richland, WA; Kintner-Meyer, Michael [Richland, WA; Winiarski, David W [Kennewick, WA; Pratt, Robert G [Kennewick, WA; Boberly-Bartis, Anne Marie [Alexandria, VA

    2008-09-02

    Electrical appliance energy consumption control methods and electrical energy consumption systems are described. In one aspect, an electrical appliance energy consumption control method includes providing an electrical appliance coupled with a power distribution system, receiving electrical energy within the appliance from the power distribution system, consuming the received electrical energy using a plurality of loads of the appliance, monitoring electrical energy of the power distribution system, and adjusting an amount of consumption of the received electrical energy via one of the loads of the appliance from an initial level of consumption to an other level of consumption different than the initial level of consumption responsive to the monitoring.

  19. Economic Model Predictive Control for Smart Energy Systems

    DEFF Research Database (Denmark)

    Halvgaard, Rasmus

    Model Predictive Control (MPC) can be used to control the energy distribution in a Smart Grid with a high share of stochastic energy production from renewable energy sources like wind. Heat pumps for heating residential buildings can exploit the slow heat dynamics of a building to store heat and ...... and hereby shift the heat pump power consumption to periods with both low electricity prices and a high fraction of green energy in the grid.......Model Predictive Control (MPC) can be used to control the energy distribution in a Smart Grid with a high share of stochastic energy production from renewable energy sources like wind. Heat pumps for heating residential buildings can exploit the slow heat dynamics of a building to store heat...

  20. Environmental effects of energy production and utilization in the U.S. Volume 3. Techniques for controlling emissions

    International Nuclear Information System (INIS)

    Newkirk, H.W.

    1976-01-01

    Technological, social, economic and political techniques for controlling emission are summarized for environmental pollutants introduced into air, water and land resources. Chemical, radiological and physical factors are discussed

  1. A reduced energy supply strategy in active vibration control

    Science.gov (United States)

    Ichchou, M. N.; Loukil, T.; Bareille, O.; Chamberland, G.; Qiu, J.

    2011-12-01

    In this paper, a control strategy is presented and numerically tested. This strategy aims to achieve the potential performance of fully active systems with a reduced energy supply. These energy needs are expected to be comparable to the power demands of semi-active systems, while system performance is intended to be comparable to that of a fully active configuration. The underlying strategy is called 'global semi-active control'. This control approach results from an energy investigation based on management of the optimal control process. Energy management encompasses storage and convenient restitution. The proposed strategy monitors a given active law without any external energy supply by considering purely dissipative and energy-demanding phases. Such a control law is offered here along with an analysis of its properties. A suboptimal form, well adapted for practical implementation steps, is also given. Moreover, a number of numerical experiments are proposed in order to validate test findings.

  2. A reduced energy supply strategy in active vibration control

    International Nuclear Information System (INIS)

    Ichchou, M N; Loukil, T; Bareille, O; Chamberland, G; Qiu, J

    2011-01-01

    In this paper, a control strategy is presented and numerically tested. This strategy aims to achieve the potential performance of fully active systems with a reduced energy supply. These energy needs are expected to be comparable to the power demands of semi-active systems, while system performance is intended to be comparable to that of a fully active configuration. The underlying strategy is called 'global semi-active control'. This control approach results from an energy investigation based on management of the optimal control process. Energy management encompasses storage and convenient restitution. The proposed strategy monitors a given active law without any external energy supply by considering purely dissipative and energy-demanding phases. Such a control law is offered here along with an analysis of its properties. A suboptimal form, well adapted for practical implementation steps, is also given. Moreover, a number of numerical experiments are proposed in order to validate test findings

  3. Energy balance of controlled thermonuclear fusion

    International Nuclear Information System (INIS)

    Hashmi, M.; Staudenmaier, G.

    2000-01-01

    It is shown that a discrepancy and incompatibility persist between basic physics and fusion-literature regarding the radiation losses from a thermonuclear plasma. Whereas the fusion-literature neglects the excitation or line radiation completely, according to basic physics it depends upon the prevailing conditions and cannot be neglected in general. Moreover, for a magnetized plasma, while the fusion-literature assumes a self-absorption or reabsorption of cyclotron or synchrotron radiation emitted by the electrons spiraling along the magnetic field, the basic physics does not allow any effective reabsorption of cyclotron or synchrotron radiation. As is demonstrated, fallacious assumptions and notions, which somehow or other crept into the fusion-literature, are responsible for this discrepancy. In the present work, the theory is corrected. On the grounds of basic physics, a complete energy balance of magnetized and non-magnetized plasmas is presented for pulsed, stationary and self-sustaining operations by taking into account the energy release by reactions of light nuclei as well as different kinds of diffusive (conduction) and radiative (bremsstrahlung, cyclotron or synchrotron radiation and excitation radiation) energy losses. Already the energy losses by radiation make the energy balance negative. Hence, a fusion reactor-an energy producing device-seems to be beyond the realms of realization. (orig.)

  4. Measurements of radiological data of some amino acids in the energy range 0.122-1.330MeV

    Energy Technology Data Exchange (ETDEWEB)

    Lokhande, Rajkumar M., E-mail: rajml358@gmail.com; More, Chaitali V.; Surung, Bharat S.; Raut, Siddheshwar D.; Pawar, Pravina P., E-mail: pravinapawar4@gmail.com [Department of physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad 431004 (India)

    2016-05-06

    Radiological parameters such as μ{sub m}, σ{sub t}, σ{sub e}, Z{sub eff} and N{sub eff} of amino acids, namely Lysine (C{sub 6}H{sub 15}N{sub 2}O{sub 2}), Histidine (C{sub 6}H{sub 9}N{sub 3}O{sub 2}) and Arginine (C{sub 6}H{sub 15}N{sub 4}O{sub 2}), were measured using NaI (Tl)-based gamma spectrometry. Radioactive sources used in the study are {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 54}Mn, {sup 60}Co and {sup 22}Na. Gamma ray transmission method in a narrow beam good geometry set up was used in the study. The measured data were compared against XCOM-based data. The agreement is within 2%.

  5. Development and evaluation of Standard Operating Procedures (SOPs) for quality control tests and radiological protection activities in a Nuclear Medicine Service

    Energy Technology Data Exchange (ETDEWEB)

    Krempser, Alexandre R., E-mail: krempser@peb.ufrj.br [Universidade Federal do Rio de Janeiro (PEB/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Biomedica; Soares, Alexandre B. [Universidade Federal do Rio de Janeiro (IF/UFRJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica; Corbo, Rossana [Universidade Federal do Rio de Janeiro (FM/UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Radiologia

    2011-07-01

    The quality management in Nuclear Medicine Services is a requirement of national and international standards. The Brazilian regulatory agency in health surveillance, the Agencia Nacional de Vigilancia Sanitaria (ANVISA), in its Resolucao de Diretoria Colegiada (Collegiate Directory Resolution) no. 38, requires the elaboration of documents describing the technical and clinical routine activities. This study aimed to elaborate, implement and evaluate Standard Operating Procedures (SOPs) for quality control tests and radiological protection activities in the Nuclear Medicine Service of a university hospital. Eighteen SOPs were developed, involving tasks related to dose calibrator, gamma camera, Geiger-Muller detectors and radiological protection activities. The performance of its application was evaluated for a period of six months. It was observed a reduction in 75% of reported operational errors and 42% of the number of reported incidents with contamination by radioactive material. The SOPs were adequate and successful in its application. New procedures involving clinical activities will also be developed and evaluated. (author)

  6. Occupational exposure in interventional radiology

    International Nuclear Information System (INIS)

    Oh, H.J.; Lee, K.Y.; Cha, S.H.; Kang, Y.K.; Kim, H.J.; Oh, H.J.

    2003-01-01

    This study was conducted to survey of radiation safety control and to measure occupational radiation exposure dose of staff in interventional radiology in Korea. Interventioanl radiology requires the operator and assisting personnel to remain close to the patient, and thus close to primary beams of radiation. Therefore exposure doses of these personnel are significant from a radiological protection point of view. We surveyed the status of radiation safety on interventional radiology of 72 hospitals. The result were that 119 radiation equipments are using in interventional radiology and 744 staffs are composed of 307 radiologists, 116 residents of radiology, 5 general physicians, 171 radiologic technologists and 145 nurses. 81.4% and 20.2 % of operating physicians are using neck collar protector and goggle respectively. The average radiation dose was measured 0.46±0.15 mSv/10 hours fluoroscopy inside examination room in radiation protection facilities. Occupational radiation exposure data on the staff were assessed in interventional radiology procedures from 8 interventional radiology equipments of 6 university hospitals. The dose measurements were made by placing a thermoluminesent dosimeter(TLD) on various body surface of operation and assistant staff during actual interventional radiology. The measured points were the corner of the eyes, neck(on the thyroid) , wrists, chest(outside and inside of the protector), and back. Average radiation equivalent dose of the corner of left eye and left wrist of operating physicians were 1.19 mSv(0.11∼4.13 mSv)/100 minutes fluoroscopy and 4.32 mSv(0.16∼11.0 mSv)/100 minutes fluoroscopy respectively. Average exposure dose may vary depending on the type of procedure, personal skills and the quality of equipment. These results will be contributed to prepare the guide line in interventional radiology in Korea

  7. A prototype system dynamic model of nuclear and radiological export controls in Central Asia and the Caucasus; enhancing the effectiveness of preventing illicit nuclear material trafficking

    International Nuclear Information System (INIS)

    Ferguston, C.D.; Ouagrham, S.B.

    2002-01-01

    An urgent need calls out for improved border security and export control systems in the Central Asian and Caucasus regions to prevent illicit nuclear and radioactive materials trafficking. Effective nuclear and radiological exports controls are essential because these regions contain numerous nuclear facilities and radioactive materials as well as lie at the crossroads between seekers and suppliers of technologies that could be employed in nuclear and radiological weapons. Porous and unprotected borders compound these concerns. Moreover, the states within these regions are struggling with forming new regulations and laws, obtaining sufficient portal monitoring equipment, training customs and border security personnel, and coordinating these activities with neighboring states. Building this infrastructure all at once can severely task any government. Thus, unsurprisingly, most of these states have inadequate export control and border security systems. To enable each state in these regions determine how to better prevent illicit nuclear and radiological materials trafficking, the authors have developed a prototype system dynamics model focused on evaluating and improving of effectiveness of export controls. System dynamics modeling, a management tool that grew out of the field of system engineering and nonlinear dynamics, uses two structures: causal loop diagrams and stock and flow diagrams. The former shows how endogenous systematic factors interact with each other to produce feedback mechanisms that results in either balancing or reinforcing loops. A classic example is a arms race, modeled as a vicious cycle or reinforcing loop. In addition to interacting with each other, causal loops influence the flow of stock, which is material concern. In the export control system dynamics model, the stock represents nuclear and radioactive materials. System dynamics modelling is an iterative process that is continually modified by user input. Therefore, export control

  8. Controlling hazardous energy sources (lockout/tagout)

    Science.gov (United States)

    Dominguez, Manuel B.

    1991-10-01

    The minimum requirements as established by the Occupational Safety and Health Administration (OSHA) standard 29 CFR 1910.147 are discussed for preventing the unexpected operation of equipment or release of energy which could cause injury to personnel, damage to equipment, harm to the environment, or loss or compromise of test data. Safety requirements both for government and contractor personnel are explained for potentially hazardous energy sources during work operations at LeRC (Cleveland and Plum Brook Stations). Basic rules are presented to ensure protection against harmful exposures, and baseline implementation requirements are discussed from which detailed lockout/tagout procedures can be developed for individual equipment items. Examples of energy sources covered by this document include electrical, pneumatic, mechanical, chemical, cryogenic, thermal, spring tension/compression suspended or moving loads, and other potentially hazardous sources. Activities covered by this standard include, but are not limited to, construction, maintenance, installation, calibration, inspection, cleaning, or repair.

  9. Chest radiology

    International Nuclear Information System (INIS)

    Reed, J.C.

    1990-01-01

    This book is a reference in plain chest film diagnosis provides a thorough background in the differential diagnosis of 22 of the most common radiologic patterns of chest disease. Each chapter is introduced with problem cases and a set of questions, followed by a tabular listing of the appropriate differential considerations. The book emphasizes plain films, CT and some MR scans are integrated to demonstrate how these modalities enhance the work of a case

  10. Suppression of chaos via control of energy flow

    Science.gov (United States)

    Guo, Shengli; Ma, Jun; Alsaedi, Ahmed

    2018-03-01

    Continuous energy supply is critical and important to support oscillating behaviour; otherwise, the oscillator will die. For nonlinear and chaotic circuits, enough energy supply is also important to keep electric devices working. In this paper, Hamilton energy is calculated for dimensionless dynamical system (e.g., the chaotic Lorenz system) using Helmholtz's theorem. The Hamilton energy is considered as a new variable and then the dynamical system is controlled by using the scheme of energy feedback. It is found that chaos can be suppressed even when intermittent feedback scheme is applied. This scheme is effective to control chaos and to stabilise other dynamical systems.

  11. A study on environmental pollution control in energy field

    Energy Technology Data Exchange (ETDEWEB)

    Min, B.M.; Son, J.E.; Lee, H.K.; Choi, W.K.; Baek, I.H.; Lee, J.S. [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    This report is contained such as following contents; Preparation of the stepwise pollution control strategies to reduce pollutants in energy field, which will be satisfy to tightened emission standard in the future. Analysis of the environmental pollution control technologies level, which related to energy field in domestic and other countries. Visualization of the reduction strategies of domestic carbon dioxide emission in energy field. And, discussion and proposal of the R and D program to improve the domestic environmental pollution control technologies in energy field. (author). 99 refs., 67 figs., 73 tabs.

  12. Application of controlled thermonuclear reactor fusion energy for food production

    International Nuclear Information System (INIS)

    Dang, V.D.; Steinberg, M.

    1975-06-01

    Food and energy shortages in many parts of the world in the past two years raise an immediate need for the evaluation of energy input in food production. The present paper investigates systematically (1) the energy requirement for food production, and (2) the provision of controlled thermonuclear fusion energy for major energy intensive sectors of food manufacturing. Among all the items of energy input to the ''food industry,'' fertilizers, water for irrigation, food processing industries, such as beet sugar refinery and dough making and single cell protein manufacturing, have been chosen for study in detail. A controlled thermonuclear power reactor was used to provide electrical and thermal energy for all these processes. Conceptual design of the application of controlled thermonuclear power, water and air for methanol and ammonia synthesis and single cell protein production is presented. Economic analysis shows that these processes can be competitive. (auth)

  13. Second Professional Specialization in Radiological Protection in Peru

    International Nuclear Information System (INIS)

    Medina-Gironzini, E.

    2004-01-01

    Considering that professionals with studies, training and experience in Radiological Protection as a Second Professional Specialization must be recognized, the Peruvian Institute of Nuclear Energy (IPEN), which is the institution responsible for the promotion and control of ionizing radiations in the country, has sign a specific agreement with the Universidad Nacional Mayor de San Marcos, in order to develop these courses. They are based on the content of the Post Graduate Course on Radiological Protection and Nuclear Safety of the Universidad de Buenos Aires, in Argentina, where more than 360 people from 27 different countries have been trained in the last 20 years. People who have a professional degree in Sciences or Engineering, and who fulfill the requirements demanded by the University, study this Second Professional Specialization in Radiological Protection. The studies last 2 years and the courses cover the following subjects: Nuclear Physics, Basic Mathematics, Basic Biology, Radiation Sources, Interaction between Radiation and Matter, Radiation Detection and Measurement, Biological effects of ionizing radiations, Radiological protection in the use of radiations in industry and medicine, Regulatory aspects, and nuclear safety - radiological protection interface. IPEN has taken the responsibility to carry out these studies due to its experience in the organization, together with different Universities, of six Masters in Nuclear Energy, four Masters in Medical Physics, one Master in Nuclear Physics, one Master in Nuclear Chemistry, and two Specialization in Nuclear Medicine. For this purpose, IPEN has the Superior Center of Nuclear Studies (CSEN), which has trained more than 2200 people in radiological protection in more than 30 years. CSEN is the first center in the country to train people in the area of nuclear energy and radiological protection. It has the best staff of professors with a both a great education and professional experience, as well as

  14. Second Professional Specialization in Radiological Protection in Peru

    Energy Technology Data Exchange (ETDEWEB)

    Medina-Gironzini, E.

    2004-07-01

    Considering that professionals with studies, training and experience in Radiological Protection as a Second Professional Specialization must be recognized, the Peruvian Institute of Nuclear Energy (IPEN), which is the institution responsible for the promotion and control of ionizing radiations in the country, has sign a specific agreement with the Universidad Nacional Mayor de San Marcos, in order to develop these courses. They are based on the content of the Post Graduate Course on Radiological Protection and Nuclear Safety of the Universidad de Buenos Aires, in Argentina, where more than 360 people from 27 different countries have been trained in the last 20 years. People who have a professional degree in Sciences or Engineering, and who fulfill the requirements demanded by the University, study this Second Professional Specialization in Radiological Protection. The studies last 2 years and the courses cover the following subjects: Nuclear Physics, Basic Mathematics, Basic Biology, Radiation Sources, Interaction between Radiation and Matter, Radiation Detection and Measurement, Biological effects of ionizing radiations, Radiological protection in the use of radiations in industry and medicine, Regulatory aspects, and nuclear safety - radiological protection interface. IPEN has taken the responsibility to carry out these studies due to its experience in the organization, together with different Universities, of six Masters in Nuclear Energy, four Masters in Medical Physics, one Master in Nuclear Physics, one Master in Nuclear Chemistry, and two Specialization in Nuclear Medicine. For this purpose, IPEN has the Superior Center of Nuclear Studies (CSEN), which has trained more than 2200 people in radiological protection in more than 30 years. CSEN is the first center in the country to train people in the area of nuclear energy and radiological protection. It has the best staff of professors with a both a great education and professional experience, as well as

  15. Intelligent control of energy-saving power generation system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhiyuan; Zhang, Guoqing; Guo, Zhizhong [Harbin Institute of Technology, Harbin (China). Dept. of Electrical Engineering

    2013-07-01

    Highway power generation system which is environmentally friendly and sustainable provides an innovative method of energy conversion. It is also as a kind of city science and technology innovation, which has the characteristics of environmental protection and sustainable utilization. Making full use of vehicle impact speed control humps, we design a new kind of highway speed control humps combined with solar electric generation system integration. Developing green energy, energy saving and environment protection can be achieved.

  16. Optimized Latching Control of Floating Point Absorber Wave Energy Converter

    Science.gov (United States)

    Gadodia, Chaitanya; Shandilya, Shubham; Bansal, Hari Om

    2018-03-01

    There is an increasing demand for energy in today’s world. Currently main energy resources are fossil fuels, which will eventually drain out, also the emissions produced from them contribute to global warming. For a sustainable future, these fossil fuels should be replaced with renewable and green energy sources. Sea waves are a gigantic and undiscovered vitality asset. The potential for extricating energy from waves is extensive. To trap this energy, wave energy converters (WEC) are needed. There is a need for increasing the energy output and decreasing the cost requirement of these existing WECs. This paper presents a method which uses prediction as a part of the control scheme to increase the energy efficiency of the floating-point absorber WECs. Kalman Filter is used for estimation, coupled with latching control in regular as well as irregular sea waves. Modelling and Simulation results for the same are also included.

  17. Energy saving in greenhouses can be obtained by energy balance-controlled screens

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, N. E. (Univ. of Aarhus, Faculty of Agricultural Sciences, Dept. of Horticulture, Aarslev (Denmark)), e-mail: niels.andersson@agrsci.dk

    2011-03-15

    The energy screens in two greenhouses, one clad with double acrylic and one with single glass, were controlled by an energy balance model. The parameters in the model were heat transmission coefficients, air temperature in the greenhouse and outdoors, irradiance and a single constant for the solar energy efficiency. The energy consumption, screen movements and daily light integral were compared with a glass greenhouse in which the energy screens were controlled by irradiance. In the greenhouse with light-controlled screens the set point for opening and closing of the screens was 5 Wm-2. The energy-saving screens controlled by the energy balance model opened later and closed earlier than in the greenhouse with light-controlled screens. When using the energy balance model the energy saving was 14% for the glass greenhouse and 41% for the double acrylic greenhouse compared with the glass greenhouse with light-controlled screens. The air temperature was on average similar in the three greenhouses, but when the screens were controlled by energy balance the daily light integral was approximately 10% lower and the number of hours the screens were closed was prolonged with 35% for the glass-covered greenhouse and 25% for the double acrylic-covered greenhouse compared with the greenhouse with light-controlled screens. Energy peaks in connection with operation of the screens were not reduced. During the experiment Begonia elatior, Dendranthema grandiflora (Chrysanthemum), Hedera helix, Helianthus annuus, Gerbera jamesonii and Kalanchoe blossfeldiana were grown in the greenhouses. There was a trend in prolongation of the production time when the plants were grown in the glass greenhouse with energy balance control of the screens. A lower number of flowers or inflorescences were observed for some of the plant species produced in the greenhouses with energy balance-controlled screens

  18. Performance maps for the control of thermal energy storage

    DEFF Research Database (Denmark)

    Finck, Christian; Li, Rongling; Zeiler, Wim

    2017-01-01

    Predictive control in building energy systems requires the integration of the building, building system, and component dynamics. The prediction accuracy of these dynamics is crucial for practical applications. This paper introduces performance maps for the control of water tanks, phase change mat...... material tanks, and thermochemical material tanks. The results show that these performance maps can fully account for the dynamics of thermal energy storage tanks.......Predictive control in building energy systems requires the integration of the building, building system, and component dynamics. The prediction accuracy of these dynamics is crucial for practical applications. This paper introduces performance maps for the control of water tanks, phase change...

  19. Fuzzy-Logic Subsumption Controller for Home Energy Management Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ainsworth, Nathan; Johnson, Brian; Lundstrom, Blake

    2015-10-06

    Home Energy Management Systems (HEMS) are controllers that manage and coordinate the generation, storage, and loads in a home. These controllers are increasingly necessary to ensure that increasing penetrations of distributed energy resources are used effectively and do not disrupt the operation of the grid. In this paper, we propose a novel approach to HEMS design based on behavioral control methods, which do not require accurate models or predictions and are very responsive to changing conditions. We develop a proof-of-concept behavioral HEMS controller and show by simulation on an example home energy system that it capable of making context-dependent tradeoffs between goals under challenging conditions.

  20. Energy Optimal Control Strategy of PHEV Based on PMP Algorithm

    Directory of Open Access Journals (Sweden)

    Tiezhou Wu

    2017-01-01

    Full Text Available Under the global voice of “energy saving” and the current boom in the development of energy storage technology at home and abroad, energy optimal control of the whole hybrid electric vehicle power system, as one of the core technologies of electric vehicles, is bound to become a hot target of “clean energy” vehicle development and research. This paper considers the constraints to the performance of energy storage system in Parallel Hybrid Electric Vehicle (PHEV, from which lithium-ion battery frequently charges/discharges, PHEV largely consumes energy of fuel, and their are difficulty in energy recovery and other issues in a single cycle; the research uses lithium-ion battery combined with super-capacitor (SC, which is hybrid energy storage system (Li-SC HESS, working together with internal combustion engine (ICE to drive PHEV. Combined with PSO-PI controller and Li-SC HESS internal power limited management approach, the research proposes the PHEV energy optimal control strategy. It is based on revised Pontryagin’s minimum principle (PMP algorithm, which establishes the PHEV vehicle simulation model through ADVISOR software and verifies the effectiveness and feasibility. Finally, the results show that the energy optimization control strategy can improve the instantaneity of tracking PHEV minimum fuel consumption track, implement energy saving, and prolong the life of lithium-ion batteries and thereby can improve hybrid energy storage system performance.

  1. [Central nervous system control of energy homeostasis].

    Science.gov (United States)

    Machleidt, F; Lehnert, H

    2011-03-01

    The brain is continuously supplied with information about the distribution and amount of energy stores from the body periphery. Endocrine, autonomic and cognitive-hedonic signals are centrally integrated and exert effects on the whole organism via anabolic and catabolic pathways. The adiposity signals insulin and leptin reflect the amount of body fat and are part of a negative feedback mechanism between the periphery and the central nervous system. The hypothalamic arcuate nucleus is the most important central nervous structure, which integrates this information. Furthermore, the CNS is able to directly measure and to respond to changes in the concentration of certain nutrients. In order to develop effective therapies for the treatment of disorders of energy balance the further elucidation of these neuro-biological processes is of crucial importance. This article provides an overview of the CNS regulation of metabolism and its underlying molecular mechanisms. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Federal Radiological Monitoring and Assessment Center (FRMAC), US response to major radiological accidents

    International Nuclear Information System (INIS)

    Mueller, P.G.

    2000-01-01

    During the 1960's and 70's the expanded use of nuclear materials to generate electricity, to provide medical benefits, and for research purposes continued to grow in the United States. While substantial effort went into constructing plants and facilities and providing for a number of redundant backup systems for safety purposes, little effort went into the development of emergency response plans for possible major radiological accidents. Unfortunately, adequate plans and procedures had not been developed to co-ordinate either state or federal emergency response assets and personnel should a major radiological accident occur. This situation became quite evident following the Three Mile Island Nuclear Reactor accident in 1979. An accident of that magnitude had not been adequately prepared for and Pennsylvania's limited emergency radiological resources and capabilities were quickly exhausted. Several federal agencies with statutory responsibilities for emergency response, including the U.S. Environmental Protection Agency (EPA), U.S. Department of Energy (DOE), Federal Emergency Management Agency (FEMA), Nuclear Regulatory Commission (NRC), and others provided extensive assistance and support during the accident. However, the assistance was not fully co-ordinated nor controlled. Following the Three Mile Island incident 13 federal agencies worked co-operatively to develop an agreement called the Federal Radiological Emergency Response Plan (FRERP). Signed in November 1985, this plan delineated the statutory responsibilities and authorities of each federal agency signatory to the FRERP. In the event of a major radiological accident, the FRERP would be activated to ensure that a co-ordinated federal emergency response would be available to respond to any major radiological accident scenario. The FRERP encompasses a wide variety of radiological accidents, not just those stemming from nuclear power plants. Activation of the FRERP could occur from major accidents involving

  3. Control of energy flow in residential buildings; Energieflussregelung in Wohngebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, Martin

    2011-07-01

    Energy systems in residential buildings are changing from monovalent, combustion based systems to multivalent systems containing technologies such as solar collectors, pellet boilers, heat pumps, CHP and multiple storages. Multivalent heat and electricity generation and additional storages raise the number of possible control signals in the system. This creates additional degrees of freedom regarding the choice of the energy converter and the instant of time for energy conversion. New functionality of controllers such as prioritisation of energy producers, optimization of electric self consumption and control of storages and energy feed-in are required. Within the scope of this thesis, new approaches for demand-driven optimal control of energy flows in multivalent building energy systems are developed and evaluated. The approaches are evaluated by means of system energy costs and operating emissions. For parametrisation of the controllers an easily understandable operating concept is developed. The energy flow controllers are implemented as a multi agent system (MAS) and a nonlinear model predictive controller (MPC). Proper functionality and stability are demonstrated in simulations of two example energy systems. In both example systems the MPC controller achieves less energy costs and operating emissions due to system wide global optimization and the more detailed system model within the controller. The multi agent approach turns out to perform better for systems with a huge number of components, e.g. in home automation and energy management systems. Due to the good performance of the reference control strategies, a significant reduction of energy costs and operating emissions is only possible with limitations. Systems for heat generation show only an especially low potential for optimization because of marginal variation ins heat production costs. The adaptation of the operation mode to user priorities, changing utilization characteristics and dynamic energy

  4. Current State Park General Radiology in the region of Murcia. 18 years of quality control; Estado actual del Parque de Radiologia General de la region de Murcia. 18 anos de controles de calidad

    Energy Technology Data Exchange (ETDEWEB)

    Vera Sanchez, J. A.; Buades Forner, M. J.; Tobarra Gonzalez, B. M.

    2011-07-01

    This paper examines the latest campaign for quality control of technical parameters of equipment carried out by l Radiological Protection Service of the Hospital Universitario Virgen de la Arrixaca, and compare the present results with those presented by this same service Congress of the Spanish Society of Medical Physics in 1993. [1], corresponding to the first quality control campaign conducted in 1992. (Author) 2 refs.

  5. Model Predictive Control for Smart Energy Systems

    DEFF Research Database (Denmark)

    Halvgaard, Rasmus

    pumps, heat tanks, electrical vehicle battery charging/discharging, wind farms, power plants). 2.Embed forecasting methodologies for the weather (e.g. temperature, solar radiation), the electricity consumption, and the electricity price in a predictive control system. 3.Develop optimization algorithms....... Chapter 3 introduces Model Predictive Control (MPC) including state estimation, filtering and prediction for linear models. Chapter 4 simulates the models from Chapter 2 with the certainty equivalent MPC from Chapter 3. An economic MPC minimizes the costs of consumption based on real electricity prices...... that determined the flexibility of the units. A predictive control system easily handles constraints, e.g. limitations in power consumption, and predicts the future behavior of a unit by integrating predictions of electricity prices, consumption, and weather variables. The simulations demonstrate the expected...

  6. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    International Nuclear Information System (INIS)

    2001-01-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  7. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  8. Radiological and administrative criteria and procedures required by the Radiation Protection Ordinance for exemption from regulatory control

    International Nuclear Information System (INIS)

    Birkholz, W.

    2000-01-01

    The system of required radioactivity measurements and limits as well as methods, based on the 10 μSv concept, constitutes the regulatory regime for exemption of radioactive waste materials from regulatory control according to atomic energy law. The methods and administrative procedures are suitable both for smaller amounts of materials, such as those resulting from the use of radioactive substances in scientific research and medical applications, and for the large waste volumes emanating from the dismantling of nuclear installations. The system provided for in the Radiation Protection Ordinance ensures harmonized administrative action of all public authorities involved. (orig./CB) [de

  9. Hierarchical fuzzy control of low-energy building systems

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Zhen; Dexter, Arthur [Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ (United Kingdom)

    2010-04-15

    A hierarchical fuzzy supervisory controller is described that is capable of optimizing the operation of a low-energy building, which uses solar energy to heat and cool its interior spaces. The highest level fuzzy rules choose the most appropriate set of lower level rules according to the weather and occupancy information; the second level fuzzy rules determine an optimal energy profile and the overall modes of operation of the heating, ventilating and air-conditioning system (HVAC); the third level fuzzy rules select the mode of operation of specific equipment, and assign schedules to the local controllers so that the optimal energy profile can be achieved in the most efficient way. Computer simulation is used to compare the hierarchical fuzzy control scheme with a supervisory control scheme based on expert rules. The performance is evaluated by comparing the energy consumption and thermal comfort. (author)

  10. Electro-mechanical energy conversion system having a permanent magnet machine with stator, resonant transfer link and energy converter controls

    Science.gov (United States)

    Skeist, S. Merrill; Baker, Richard H.

    2006-01-10

    An electro-mechanical energy conversion system coupled between an energy source and an energy load comprising an energy converter device including a permanent magnet induction machine coupled between the energy source and the energy load to convert the energy from the energy source and to transfer the converted energy to the energy load and an energy transfer multiplexer to control the flow of power or energy through the permanent magnetic induction machine.

  11. Direct Energy Centre underground parking integrated light control system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-10-15

    LightSavers is a project undertaken by the Toronto Atmospheric Fund to accelerate the use of lighting technologies. As part of the project a pilot test has been carried out in the Direct Energy Center in Toronto. The aim of this report is to present the study and its results. The Direct Energy Center is a large event facility with an large underground parking facility. A lighting energy management system, the energy control system (ECS), capable of adjusting lighting levels based on occupancy was implemented in the centre and data was collected during over one year. Results showed that the ECS permitted a reduction in energy consumption and thus greenhouse gas emissions by 47% and the payback will take less than 6 years. This project demonstrated that the energy control system provides better energy, environmental and economic performance than a traditional automation system.

  12. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  13. APPLICATION OF NONLINEAR PID CONTROLLER IN SUPERCONDUCTING MAGNETIC ENERGY STORAGE

    OpenAIRE

    PENG, Xiaotao; CHENG, Shijie

    2011-01-01

    As a new control strategy, Nonlinear PID(NLPID) controller has been introduced in the power system successfully. The controller is free of planting model foundation in the design procedure and realized simply. In this paper, a nonlinear PID controller used for superconducting magnetic energy storage (SMES) unit connected to a power system is proposed. Purpose of designing such controller is to improve the stability of the power system in a relatively wide operation range. The design procedure...

  14. Hybrid vehicle energy management: singular optimal control

    NARCIS (Netherlands)

    Delprat, S.; Hofman, T.; Paganelli, S.

    2017-01-01

    Hybrid vehicle energymanagement is often studied in simulation as an optimal control problem. Under strict convexity assumptions, a solution can be developed using Pontryagin’s minimum principle. In practice, however, many engineers do not formally check these assumptions resulting in the possible

  15. Geothermal energy control system and method

    Science.gov (United States)

    Matthews, Hugh B.

    1977-01-01

    A geothermal energy transfer and utilization system makes use of thermal energy stored in hot solute-bearing well water to generate super-heated steam from an injected flow of clean water; the super-heated steam is then used for operating a turbine-driven pump at the well bottom for pumping the hot solute-bearing water at high pressure and in liquid state to the earth's surface, where it is used by transfer of its heat to a closed-loop boiler-turbine-alternator combination for the generation of electrical or other power. Residual concentrated solute-bearing water is pumped back into the earth. The clean cooled water is regenerated at the surface-located system and is returned to the deep well pumping system also for lubrication of a novel bearing arrangement supporting the turbine-driven pump system. The bearing system employs liquid lubricated thrust and radial bearings with all bearing surfaces bathed in clean water serving as a lubricant and maintained under pressure to prevent entry into the bearings of contaminated geothermal fluid, an auxiliary thrust ball bearing arrangement comes into operation when starting or stopping the pumping system.

  16. Cardiothoracic radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.

    2005-01-01

    A wealth of cardiothoracic websites exist on the internet. What follows is a list of the higher quality resources currently available which should save you time searching them out for yourself. Many of the sites listed cater for undergraduates and trainee or non-specialist radiologists, nevertheless these may also be of interest to specialists in thoracic radiology, particularly for use in teaching. Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (April 2005)

  17. Pediatric radiology

    International Nuclear Information System (INIS)

    Silverman, F.N.

    1982-01-01

    A literature review with 186 references of diagnostic pediatric radiology, a speciality restricted to an age group rather than to an organ system or technique of examination, is presented. In the present chapter topics follow the basic organ system divisions with discussions of special techniques within these divisions. The diagnosis of congenital malformations, infectious diseases and neoplasms are a few of the topics discussed for the head and neck region, the vertebrae, the cardiovascular system, the respiratory system, the gastrointestinal tract, the urinary tract, and the skeleton

  18. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  19. Energy Management Control Systems: Tools for Energy Savings and Environmental Protection

    Science.gov (United States)

    Zsebik, Albin; Zala, Laszlo F.

    2002-01-01

    The change in the price of energy has encouraged the increase of energy efficiency. This report will discuss a tool to promote energy efficiency in intelligent buildings, energy management control systems (EMCS). In addition to the online control of energy production, supply, and consumption, the function of the EMCS is to support short- and long-term planning of the system operation as well as to collect, store, and regularly evaluate operation data. The strategies behind planning and implementing the EMCS as well as the manipulating the resulting data are discussed in this report.

  20. A Novel Coordinated Control of Renewable Energy Sources and Energy Storage System in Islanded Microgrid

    DEFF Research Database (Denmark)

    Gui, Yonghao; Li, Mingshen; Guerrero, Josep M.

    2018-01-01

    A novel coordinated control for energy storage system (ESS) and renewable energy source (RES) units is proposed in islanded AC microgrids without a phase-locked loop system. We use a proportional-resonant control technique for the ESS, which fixes the voltage and frequency of the microgrid...

  1. CP-50 calibration facility radiological safety assessment document

    International Nuclear Information System (INIS)

    Chilton, M.W.; Hill, R.L.; Eubank, B.F.

    1980-03-01

    The CP-50 Calibration Facility Radiological Safety Assessment document, prepared at the request of the Nevada Operations Office of the US Department of Energy to satisfy provisions of ERDA Manual Chapter 0531, presents design features, systems controls, and procedures used in the operation of the calibration facility. Site and facility characteristics and routine and non-routine operations, including hypothetical incidents or accidents are discussed and design factors, source control systems, and radiation monitoring considerations are described

  2. Compressed Air Energy Storage System Control and Performance Assessment Using Energy Harvested Index

    Directory of Open Access Journals (Sweden)

    Hanif SedighNejad

    2014-01-01

    Full Text Available In this paper a new concept for control and performance assessment of compressed air energy storage (CAES systems in a hybrid energy system is introduced. The proposed criterion, based on the concept of energy harvest index (HEI, measures the capability of a storage system to capture renewable energy. The overall efficiency of the CAES system and optimum control and design from the technical and economic point of view is presented. A possible application of this idea is an isolated community with significant wind energy resource. A case study reveals the usefulness of the proposed criterion in design, control and implementation of a small CAES system in a hybrid power system (HPM for an isolated community. Energy harvested index and its effectiveness in increasing the wind penetration rate in the total energy production is discussed.

  3. Radiological Worker Training: Radiological Worker 2 lesson plans

    International Nuclear Information System (INIS)

    1992-10-01

    Upon completion of this g course, the participant will have the knowledge to work safely in areas controlled for a radiological purposes using proper radiological practices. The participant will be able toidentify the fundamentals of radiation, radioactive material and radioactive contamination includes identify the three basic particles of an atom, define ionization, define ionizing radiation, radioactive material and radioactive contamination, distinguish between ionizing radiation and non-ionizing radiation, define radioactivity and radioactive half-life

  4. Atomic Energy Control Board vocabulary - preliminary edition

    International Nuclear Information System (INIS)

    Nolet, D.

    1995-09-01

    This preliminary edition was prepared at the Board's request to help it establish a standardized terminology. It was produced by scanning the 99 French and English documents listed at the end of this Vocabulary. The documents include legislation concerning atomic energy and the transportation of radioactive materials, as well as the Board's publications, such as the Consultative Documents, Regulatory Documents and Notices. The terms included from the following areas are: radiation protection, reactor technology, nuclear fuel cycle, radioactive material packaging and transportation, radioactive waste management, uranium mines, and medical and industrial applications of radioelements. Also included are the titles of publications and the names of organizations and units. The vocabulary contains 2,589 concepts, sometimes accompanied by definitions, contexts or usage examples. Where terms have been standardized by the Canadian Committee for the Standardization of Nuclear Terminology, this has been indicated. Where possible, we have verified the terms using the TERMIUM, the Government of Canada Linguistic Data Bank. (author)

  5. Coordinated Control of Wave Energy Converters Subject to Motion Constraints

    Directory of Open Access Journals (Sweden)

    Liguo Wang

    2016-06-01

    Full Text Available In this paper, a generic coordinated control method for wave energy converters is proposed, and the constraints on motion amplitudes and the hydrodynamic interaction between converters are considered. The objective of the control problem is to maximize the energy converted from ocean waves, and this is achieved by coordinating the power take-off (PTO damping of each wave energy converter in the frequency domain in each sea state. In a case study, a wave energy farm consisting of four converters based on the concept developed by Uppsala University is studied. In the solution, motion constraints, including constraints on the amplitudes of displacement and velocity, are included. Twelve months of sea states, based on measured wave data at the Lysekil test site on the Swedish west coast, are used in the simulation to evaluate the performance of the wave energy farm using the new method. Results from the new coordinated control method and traditional control method are compared, indicating that the coordinated control of wave energy converters is an effective way to improve the energy production of wave energy farm in harmonic waves.

  6. Radiological effects

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Environmental monitoring in the vicinity of the Calvert Cliffs Nuclear Power Plant has been shown the radiation dose to the public from plant operation to be quite small. Calculations from the reported release rates yield 0.2 mrem whole body dose and 0.6 mrem skin dose for the calendar quarter of maximum release. Radioactivity discharges to the Chesapeake Bay have resulted in detectable concentrations of /sup 110m/Ag, 58 Co, and 60 Co in sediments and shellfish. The area yielding samples with detectable concentrations of plant effluents extends for roughly six miles up and down the western shore, with maximum values found at the plant discharge area. The radiation dose to an individual eating 29 doz oysters and 15 doz crabs (5 kg of each) taken from the plant discharge area would be about 4/1000 mrem whole body dose and 0.2 mrem gastrointestinal tract dose (about 0.007% and 0.5% of the applicable guidelines, respectively.) Comparison of these power plant-induced doses with the fluctuations in natural radiation dose already experienced by the public indicates that the power plant effects are insignificant. The natural variations are tens of times greater than the maximum doses resulting from Calvert Cliffs Power Plant. Although operations to date provide an insufficient basis to predict radiological impact of the Calvert Cliffs Plant over its operational lifetime, available data indicate that the plant should continue to operate with insignificant radiological impact, well within all applicable guidelines

  7. Pediatric radiology

    International Nuclear Information System (INIS)

    Kirkpatrick, J.A. Jr.

    1985-01-01

    Computed tomography has made possible the excellent and basic work having to do with the characteristics of the trachea, its caliber, shape, and length in children. Another group of articles has to do with interventional pediatric radiology. This year there were a number of articles of which only a sample is included, dealing with therapeutic procedures involving drainage of abscesses, angioplasty, nephrostomy, therapeutic embolization, and the removal of esophageal foreign bodies. Obviously, there is no reason to think that techniques developed for the adult may not be applicable to the infant or child; also, there is no reason to believe that processes peculiar to the child should not be amenable to intervention, for instance, use of embolization of hepatic hemangioma and transluminal balloon valvuloplasty for pulmonary valvular stenosis. Among the reports and reviews, the author would add that sonography remains a basic imaging technique in pediatric radiology and each year its application broadens. For example, there is an excellent article having to do with sonography of the neonatal and infant hip and evaluation of the inferior vena cava and the gallbladder. Nuclear medicine continues to play a significant role in diagnosis, which is featured in two articles concerned with problems of the hip

  8. Radiological malpractice

    International Nuclear Information System (INIS)

    Bauer, G.

    1987-01-01

    As medico-legal statistics show, compared with other branches of medicine, cases of liability of the radiologist or his assistants are relatively rare. The duty to exercise due care as set out in Paragraph 6 of the Austrian penal code or Paragraph 276 of the German civil code, respectively, provide a basic rule of law also for radiology. Due to the risk inherent in the investigation method, incidents in angiography cannot be totally excluded. Therefore, it is of utmost importance that all steps be taken with regard to staff, equipment and drugs to be able to deal with any complications and incidents that may arise. The courts of law require the employer to produce strongest exonerating evidence to prove that the duty to exercise due care in the selection and supervision of the assistants has been duly fulfilled. For the practical execution of radiological investigations of the digestive tract, also the RTA is responsible; her liability when performing an irrigoscopy is particularly great, as perforation of the intestine is often lethal. The introduction of the rectal tube into the vagina by mistake, with resultant injury or death of the patient, will regularly lead to conviction under penal law. (orig.) [de

  9. Comparative evaluation of image quality of various digital radiology systems and quality control and optimization of radiation protection at the Amiens university hospital

    International Nuclear Information System (INIS)

    Foro, Saturnin Didace L.

    2004-01-01

    This study was centered on two axes: the first is the comparative evaluation of image quality of various numerical radiology system, the second is the quality control and the optimization of protection against radiation. The publication of directive 97/43 Euratom from council of June 30, 1997 and consequently, the decree of February 12, 2004 founded a strict lawful framework that is engaged to respect the University Hospital of Amiens by the installation of a operational dosimetry system and the application of February 12, 2004 decree. (author) [fr

  10. Introduction to radiological performance assessment

    International Nuclear Information System (INIS)

    Moss, G.

    1995-02-01

    A radiological performance assessment is conducted to provide reasonable assurance that performance objectives for low-level radioactive waste (LLW) disposal will be met. Beginning in the early stages of development, a radiological performance assessment continues through the operational phase, and is instrumental in the postclosure of the facility. Fundamental differences exist in the regulation of commercial and defense LLW, but the radiological performance assessment process is essentially the same for both. The purpose of this document is to describe that process in a concise and straightforward manner. This document focuses on radiological performance assessment as it pertains to commercial LLW disposal, but is applicable to US Department of Energy sites as well. Included are discussions on performance objectives, site characterization, and how a performance assessment is conducted. A case study is used to illustrate how the process works as a whole. A bibliography is provided to assist in locating additional information

  11. The Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Hall, E.J.

    1992-05-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) -- formerly the Radiological Research Laboratory (RRL) -- of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). As such, RARAF is available to all potential users on an equal basis, and scientists outside the CRR are encouraged to submit proposals for experiments at RARAF. The operation of the Van de Graaff is supported by the DOE, but the research projects themselves must be supported separately. Experiments performed from May 1991--April 1992 are described

  12. The Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Hall, E.J.; Marino, S.A.

    1991-05-01

    The Radiological Research Accelerator Facility (RARAF) is based on 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) -- formerly the Radiological Research Laboratory (RRL) -- of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). As such, RARAF is available to all potential users on an equal basis, and scientists outside the CRR are encouraged to submit proposals for experiments at RARAF. The operation of the Van de Graaff is supported by the DOE, but the research projects themselves must be supported separately. Brief summaries of research experiments are included. Accelerator usage is summarized and development activities are discussed. 8 refs., 8 tabs

  13. The Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Hall, E.J.; Marino, S.A.

    1993-05-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) - formerly the Radiological Research Laboratory of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). As such, RARAF is available to all potential users on an equal basis and scientists outside the CRR are encouraged to submit proposals for experiments at RARAF. The operation of the Van de Graaff is supported by the DOE, but the research projects themselves must be supported separately. This report provides a listing and brief description of experiments performed at RARAF during the May 1, 1992 through April 30, 1993

  14. Energy Storage System Control Algorithm by Operating Target Power to Improve Energy Sustainability of Smart Home

    OpenAIRE

    Byeongkwan Kang; Kyuhee Jang; Sounghoan Park; Myeong-in Choi; Sehyun Park

    2018-01-01

    As energy issues are emerging around the world, a variety of smart home technologies aimed at realizing zero energy houses are being introduced. Energy storage system (ESS) for smart home energy independence is increasingly gaining interest. However, limitations exist in that most of them are controlled according to time schedules or used in conjunction with photovoltaic (PV) generation systems. In consideration of load usage patterns and PV generation of smart home, this study proposes an ES...

  15. Energy control of supercapacitor/fuel cell hybrid power source

    International Nuclear Information System (INIS)

    Payman, Alireza; Pierfederici, Serge; Meibody-Tabar, Farid

    2008-01-01

    This paper deals with a flatness based control principle in a hybrid system utilizing a fuel cell as a main power source and a supercapacitor as an auxiliary power source. The control strategy is based on regulation of the dc bus capacitor energy and, consequently, voltage regulation. The proposed control algorithm does not use a commutation algorithm when the operating mode changes with the load power variation and, thus, avoids chattering effects. Using the flatness based control method, the fuel cell dynamic and its delivered power is perfectly controlled, and the fuel cell can operate in a safe condition. In the hybrid system, the supercapacitor functions during transient energy delivery or during energy recovery situations. To validate the proposed method, the control algorithms are executed in dSPACE hardware, while analogical current loops regulators are employed in the experimental environment. The experimental results prove the validity of the proposed approach

  16. Qt based control system software for Low Energy Accelerator Facility

    International Nuclear Information System (INIS)

    Basu, A.; Singh, S.; Nagraju, S.B.V.; Gupta, S.; Singh, P.

    2012-01-01

    Qt based control system software for Low Energy Accelerating Facility (LEAF) is operational at Bhabha Atomic Research Centre (BARC), Trombay, Mumbai. LEAF is a 50 keV negative ion electrostatic accelerator based on SNICS ion source. Control system uses Nokia Trolltech's QT 4.x API for control system software. Ni 6008 USB based multifunction cards has been used for control and read back field equipments such as power supplies, pumps, valves etc. Control system architecture is designed to be client server. Qt is chosen for its excellent GUI capability and platform independent nature. Control system follows client server architecture. The paper will describe the control system. (author)

  17. Lessons learned in radiology

    International Nuclear Information System (INIS)

    Goodenough, D.J.

    2001-01-01

    The paper reviews aspects of the history of radiology with the goal of identifying lessons learned, particularly in the area of radiological protection of the patient in diagnostic and interventional radiology, nuclear medicine and radiotherapy. It is pointed out that since the days of Roentgen there has been a need not only to control and quantify the amount of radiation reaching the patient but also to optimize the imaging process to offer the greatest diagnostic benefit within allowable levels of patient dose. To this end, in diagnostic radiology, one finds the development of better films, X rays tubes, grids, screens and processing techniques, while in fluoroscopy, one sees the increased luminance of calcium tungstate. In interventional radiology, one finds an improvement in catheterization techniques and contrast agents. In nuclear medicine, the development of tracer techniques into modern cameras and isotopes such as technetium can be followed. In radiotherapy, one sees the early superficial X rays and radium sources gradually replaced with radon seeds, supervoltage, 60 Co and today's linear accelerators. Along with the incredible advances in imaging and therapeutic technologies comes the growing realization of the potential danger of radiation and the need to protect the patient (as well as physicians, ancillary personnel and the general population) from unnecessary radiation. The important lesson learned is that we must walk a tightrope, balancing the benefits and risks of any technology utilizing radiation to produce the greatest benefits at the lowest acceptable risk. The alternative techniques using non-ionizing radiation will have to be considered as part of the general armamentarium for medical imaging whenever radiation consequences are unacceptable. (author)

  18. The energy consumption of control systems; Het energiegebruik van regelinstallaties

    Energy Technology Data Exchange (ETDEWEB)

    Van Gulik, A.R.; De Wildt, M.G. [Grontmij Nederland, Amersfoort (Netherlands)

    2013-07-15

    Control systems for e.g. indoor climate and illumination are essential in modern building services, and useful for comfort or energy conservation. Energy conservation is of course an important aim, but what is the energy consumption of the control systems? Is the consumption higher than the savings? This question was subject of a comprehensive study, with measurements and simulation calculations. It can be concluded that the energy consumption of control installation for spaces is substantial [Dutch] Regelinstallaties voor bijvoorbeeld klimaatregeling, verlichtingsregeling en domotica zijn niet meer weg te denken uit de moderne installatietechniek, of ze nu dienen voor comfort, gemak of energiebesparing. Maar hoeveel energie gebruiken deze installaties eigenlijk? Voor ontwerpers blijkt dit helemaal geen issue te zijn terwijl adviseurs, installateurs en zelfs fabrikanten zeggen hiervan geen idee te hebben. Door metingen en het gebruik van berekeningsmodellen is vastgesteld wat het energiegebruik van regelinstallaties op jaarbasis is. Dit blijkt substantieel te zijn, maar er zijn mogelijkheden om het gebruik te reduceren.

  19. Turbine Energy Evaluation by internal dimensional control

    International Nuclear Information System (INIS)

    Mediavilla, F.

    2000-01-01

    To maintain the optimum thermal performance in a high level throughout the life of the turbines requires a good testing program, proper analysis of the test data, and a steam path audit during turbine overhauls. If from operating data analysis collected during the performance test before the outage shows that the efficiency of the turbine is coming down, the steam path audit, that is an internal inspection and a dimensional control of the internals, identity and quantity causes of performance degradation like, seal leakages, excessive clearances, solid particle erosion damages, blades deposits and other losses. The steam path audit assigns the heat rate penalties associated with each of these individual losses to the total degradation. This are used to make cost-effective maintenance decisions during the course of the overhaul. After repairs, a closing steam path audit is conducted during the re assembly of the turbine in order to predict return to service condition of the machine and to provide a quality control check on outage repairs. (Author)

  20. Atomic Energy Control Board vocabulary - preliminary edition

    Energy Technology Data Exchange (ETDEWEB)

    Nolet, D [Public Works and Government Services Canada, Montreal, PQ (Canada). Terminology and Documentation Directorate

    1995-09-01

    This preliminary edition was prepared at the Board`s request to help it establish a standardized terminology. It was produced by scanning the 99 French and English documents listed at the end of this Vocabulary. The documents include legislation concerning atomic energy and the transportation of radioactive materials, as well as the Board`s publications, such as the Consultative Documents, Regulatory Documents and Notices. The terms included from the following areas are: radiation protection, reactor technology, nuclear fuel cycle, radioactive material packaging and transportation, radioactive waste management, uranium mines, and medical and industrial applications of radioelements. Also included are the titles of publications and the names of organizations and units. The vocabulary contains 2,589 concepts, sometimes accompanied by definitions, contexts or usage examples. Where terms have been standardized by the Canadian Committee for the Standardization of Nuclear Terminology, this has been indicated. Where possible, we have verified the terms using the TERMIUM, the Government of Canada Linguistic Data Bank. (author).

  1. Radiological training for tritium facilities

    International Nuclear Information System (INIS)

    1996-12-01

    This program management guide describes a recommended implementation standard for core training as outlined in the DOE Radiological Control Manual (RCM). The standard is to assist those individuals, both within DOE and Managing and Operating contractors, identified as having responsibility for implementing the core training recommended by the RCM. This training may also be given to radiological workers using tritium to assist in meeting their job specific training requirements of 10 CFR 835

  2. Radiological training for tritium facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    This program management guide describes a recommended implementation standard for core training as outlined in the DOE Radiological Control Manual (RCM). The standard is to assist those individuals, both within DOE and Managing and Operating contractors, identified as having responsibility for implementing the core training recommended by the RCM. This training may also be given to radiological workers using tritium to assist in meeting their job specific training requirements of 10 CFR 835.

  3. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  4. Controlled Environmental Agriculture and Energy Project

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Chris [Morrisville State College, NY (United States)

    2012-07-27

    Task A: Heating Plant - To design/build a Heating Plant Building with associated heating components for heating the greenhouse and to house the biomass gasification system. The subtasks for this task was and Engineering Design, Procurement and Construction activities. Overall milestones for this task were one construction permit, a code review and stamped drawings, engineered building vendor supplied sealed drawings, and the actual erection of a 1250 sq.ft. building. Task B: Heating System - The activities for this task included the procurement of the heating boilers and all ancillary components. This also included the installation of all heating system components in the new building plus the existing greenhouse structure. The milestone for this task was for the ability to heat 2500 gallons of water to 80 degrees F. Task C: Organic Matter Automated Hopper - The activities involved in this task involved design/fabrication of an automated hopper to feed the biomass gasification system. We need to procure materials and the automated motion components, have the system installed and factory acceptance test of the system. The milestone is to be able to feed wood chips at a rate of 20 Kg/Hr. Task D: Imbert Gasification System - The activities involved in this include the design/build of the gasifier with all accompany ductwork, cyclones and feeding system. Also there is a modification to the scrubber assembly with an automated ash removal system. Lastly a modification to the exhaust/flair system is made to capture heat from this component. Milestone for this task was to be able to produce 15 CFM of SynGas. Task E: Generator Powered by SynGas - Procure two 20kW 4 pole generator heads for installation on the gasifier system. Modification of the fuel plenum manifold with adjustment to the fuel curves for maximum power and load points. Milestone for this task is the ability to run two fuels, either SynGas or propane. This continues with the following tasks: Controls Heating

  5. Intelligent control with implementation on the wind energy conversion system

    International Nuclear Information System (INIS)

    Basma, Mohamad Khalil

    1997-05-01

    In this thesis our main job is to compare intelligent control and conventional control algorithms, by applying each scheme to the same control problem. Based on simulation, we analyze and compare the results of applying fuzzy logic and neural networks controllers on a popular control problem: variable speed wind energy conversion system. The reason behind our choice is the challenging nature of the problem where the plant should be controlled to maximize the power generated, while respecting its hardware constraints under varying operating conditions and disturbances. We have shown the effectiveness of fuzzy logic exciter controller for the adopted wind energy generator when compared to a conventional PI exciter. It showed better performance in the whole operating range. However, in the high wind speeds region, both controllers were unable to deliver the rpm requirements. We proposed the use of neural network intelligent techniques to supply us the optimal pitch. Our aim was to develop a simple and reliable controller that can deliver this optimal output, while remaining adaptive to system uncertainties and disturbances. The proposed fuzzy controller with a neural pitch controller showed best dynamic and robust performance as compared to the adaptive pitch controller together with the PI exciter. This study has shown that artificial neural networks and fuzzy logic control algorithms can be implemented for real time control implementations. the neuro-fuzzy control approach is robust and its performance is superior to that of traditional control methods. (author)

  6. Secure Control Systems for the Energy Sector

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Rhett [Schweitzer Engineering Lab., Inc., Alpharetta, GA (United States); Stewart, John [Tennessee Valley Authority, Knoxville, TN (United States); Chavez, Adrian [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-10-22

    The Padlock Project is an alliance between Tennessee Valley Authority (TVA), Sandia National Laboratories (SNL), and Schweitzer Engineering Laboratories Inc. (SEL). SEL is the prime contractor on the Padlock project. Rhett Smith (SEL) is the project director and Adrian Chaves (SNL) and John Stewart (TVA) are principle investigators. SEL is the world’s leader in microprocessor-based electronic equipment for protecting electric power systems. The Tennessee Valley Authority, a corporation owned by the U.S. government, provides electricity for 9 million people in parts of seven southeastern states at prices below the national average. TVA, which receives no taxpayer money and makes no profits, also provides flood control, navigation and land management for the Tennessee River system and assists utilities, and state and local governments with economic development.

  7. Passive and Active Vibration Control of Renewable Energy Structures

    DEFF Research Database (Denmark)

    Zhang, Zili

    The present thesis deals with fundamental researches on passive and active vibration control of renewable energy structures, and provides useful models for practical applications. Effective and robust vibration control methods have been explored for mitigating the lightly damped edgewise blade...... solutions for wave energy point absorbers, in order to maximize the mean absorbed power and to deliver more smooth power to the grid. A novel suboptimal causal control law has been established for controlling the motion of the point absorber, and a new type of point absorber has also been proposed...

  8. Control Strategies for Arrays of Wave Energy Devices

    OpenAIRE

    Westphalen, J; Bacelli, G; Balitsky, P; Ringwood, John

    2011-01-01

    In this paper, we investigate the differences between two control strategies for a two-device linear array of wave energy converters (WEC) for device spacings of 4 to 80 times the device diameter. The WECs operate in heave only and are controlled in real time. The control strategies, called the independent device and global array control, estimate the excitation forces and calculate the optimum vertical velocity trajectory and reactive power take off force to achieve the ...

  9. A review of residential computer oriented energy control systems

    Energy Technology Data Exchange (ETDEWEB)

    North, Greg

    2000-07-01

    The purpose of this report is to bring together as much information on Residential Computer Oriented Energy Control Systems as possible within a single document. This report identifies the main elements of the system and is intended to provide many technical options for the design and implementation of various energy related services.

  10. The energy cost for balance control during upright standing

    NARCIS (Netherlands)

    Houdijk, J.H.P.; Fickert, R.; van Velzen, J.; van Bennekom, C.A.M.

    2009-01-01

    The aim of this study was to investigate whether balance control during a static upright standing task with and without balance perturbations elicits a significant and meaningful metabolic energy demand and to test whether this energy demand correlates with conventional posturography measures for

  11. Software systems for energy control in the English industry

    International Nuclear Information System (INIS)

    Bouma, J.W.J.

    1993-01-01

    Monitoring and targeting software systems have proved to be valuable tools for energy control, permitting to save five to ten percent of energy. The article reviews the systems that are presently available in England and illustrates how these systems are successfully used in practice in small (British Telecom) and middle large (Charles Wells Brewery) industrial applications. (A.S.)

  12. Design of Energy Efficient SMISMO-ELS Control Strategies

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Andersen, Torben Ole

    2011-01-01

    Traditionally mechanical linked meter-in and meterout spool valves are used for velocity control of hydraulic differential cylinders. However with the demand for energy efficient systems the individual meter-in and meter-out valves draws massive attention. This paper propose an energy efficient a...

  13. Advanced Grid Control Technologies Workshop Series | Energy Systems

    Science.gov (United States)

    : Smart Grid and Beyond John McDonald, Director, Technical Strategy and Policy Development, General Control Technologies Workshop Series In July 2015, NREL's energy systems integration team hosted workshops the Energy Systems Integration Facility (ESIF) and included a technology showcase featuring projects

  14. Adaptive Media Access Control for Energy Harvesting - Wireless Sensor Networks

    DEFF Research Database (Denmark)

    Fafoutis, Xenofon; Dragoni, Nicola

    2012-01-01

    ODMAC (On-Demand Media Access Control) is a recently proposed MAC protocol designed to support individual duty cycles for Energy Harvesting — Wireless Sensor Networks (EH-WSNs). Individual duty cycles are vital for EH-WSNs, because they allow nodes to adapt their energy consumption to the ever-ch...

  15. Smart Control of Energy Distribution Grids over Heterogeneous Communication Networks

    DEFF Research Database (Denmark)

    Olsen, Rasmus Løvenstein; Iov, Florin; Hägerling, Christian

    2014-01-01

    The expected growth in distributed generation will significantly affect the operation and control of todays distribution grids. Being confronted with short time power variations of distributed generations, the assurance of a reliable service (grid stability, avoidance of energy losses) and the qu......The expected growth in distributed generation will significantly affect the operation and control of todays distribution grids. Being confronted with short time power variations of distributed generations, the assurance of a reliable service (grid stability, avoidance of energy losses...

  16. Feedback control and adaptive control of the energy resource chaotic system

    International Nuclear Information System (INIS)

    Sun Mei; Tian Lixin; Jiang Shumin; Xu Jun

    2007-01-01

    In this paper, the problem of control for the energy resource chaotic system is considered. Two different method of control, feedback control (include linear feedback control, non-autonomous feedback control) and adaptive control methods are used to suppress chaos to unstable equilibrium or unstable periodic orbits. The Routh-Hurwitz criteria and Lyapunov direct method are used to study the conditions of the asymptotic stability of the steady states of the controlled system. The designed adaptive controller is robust with respect to certain class of disturbances in the energy resource chaotic system. Numerical simulations are presented to show these results

  17. Trends in Energy Management Technology - Part 3: State of Practiceof Energy Management, Control, and Information Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Gaymond; Webster, Tom

    2004-02-01

    In this report, the third in a series, we provide an evaluation of several products that exemplify the current state of practice of Energy Management, Control, and Information Systems (EMCIS). The available features for these products are summarized and analyzed with regard to emerging trends in EMCIS and potential benefits to the federal sector. The first report [1] covered enabling technologies for emerging energy management systems. The second report [2] serves as a basic reference for building control system (BCS) networking fundamentals and includes an assessment of current approaches to open communications. Part 4 of this series will discuss applications software from a user's perspective. It is important for energy managers in the Federal sector to have a high level of knowledge and understanding of these complex energy management systems. This series of reports provides energy practitioners with some basic informational and educational tools to help make decisions relative to energy management systems design, specification, procurement, and energy savings potential.

  18. Investigative report, science committee of Aggregate corporation Radiological technologist society of the Oita prefecture. Questionnaires research on security control of department of radiological technology of medical facilities in the Oita prefecture. The second report. Research on high risk incident measures

    International Nuclear Information System (INIS)

    Eto, Yoshihiro; Mano, Isao; Takagi, Ikuya; Murakami, Yasunori; Sueyoshi, Seiji; Yoshimoto, Asahi

    2007-01-01

    Oita association of radiological technologists carried out the questionnaires about the measures against high lisk incidental in department of radiological technology at the medical facilities in Oita. We distributed the questionnaire to 102 facilities, which are worked by the technologists (member), and got response from 91 facilities (89%). Research contents are Patient verification method'' ''Input and verification of patient attribute'' ''Infection in hospital'' ''Stumbles and falls of patient'' Contrast enhancement CT'' ''Something related to pacemaker'' ''MRI inspection and the magnetic substance'' ''Remedy mistake'' and ''Risk management''. The Result, Low level recognition contents of medical accident measures are ''Contrast enhancement CT'' ''Stumbles and falls of patient'' Risk management of department of radiological technology''. (author)

  19. Digital radiology

    International Nuclear Information System (INIS)

    Dallas, W.J.

    1990-01-01

    Radiology is vital to the life-saving efforts of surgeons and other physicians, but precious time can be lost generating the images and transferring them to and from the operating room. Furthermore, hospitals are straining under the task of storing and managing the deluge of diagnostic films produced every year. A 300-bed hospital generates about 1 gigabyte (8 x 10 9 bits) of picture information every day and is legally bound to hold it for three to seven years--30 years in the case of silicosis or black lung disease, illnesses that may have relevance to future lawsuits. Consequently, hospital warehouses are filling with x-ray film and written reports that are important for analysis of patient histories, for comparison between patients, and for analyzing the progress of disease. Yet only a fraction of the information's potential is being used because access is so complicated. What is more, films are easily lost, erasing valuable medical histories

  20. Stochastic control of inertial sea wave energy converter.

    Science.gov (United States)

    Raffero, Mattia; Martini, Michele; Passione, Biagio; Mattiazzo, Giuliana; Giorcelli, Ermanno; Bracco, Giovanni

    2015-01-01

    The ISWEC (inertial sea wave energy converter) is presented, its control problems are stated, and an optimal control strategy is introduced. As the aim of the device is energy conversion, the mean absorbed power by ISWEC is calculated for a plane 2D irregular sea state. The response of the WEC (wave energy converter) is driven by the sea-surface elevation, which is modeled by a stationary and homogeneous zero mean Gaussian stochastic process. System equations are linearized thus simplifying the numerical model of the device. The resulting response is obtained as the output of the coupled mechanic-hydrodynamic model of the device. A stochastic suboptimal controller, derived from optimal control theory, is defined and applied to ISWEC. Results of this approach have been compared with the ones obtained with a linear spring-damper controller, highlighting the capability to obtain a higher value of mean extracted power despite higher power peaks.

  1. Stochastic Control of Inertial Sea Wave Energy Converter

    Science.gov (United States)

    Mattiazzo, Giuliana; Giorcelli, Ermanno

    2015-01-01

    The ISWEC (inertial sea wave energy converter) is presented, its control problems are stated, and an optimal control strategy is introduced. As the aim of the device is energy conversion, the mean absorbed power by ISWEC is calculated for a plane 2D irregular sea state. The response of the WEC (wave energy converter) is driven by the sea-surface elevation, which is modeled by a stationary and homogeneous zero mean Gaussian stochastic process. System equations are linearized thus simplifying the numerical model of the device. The resulting response is obtained as the output of the coupled mechanic-hydrodynamic model of the device. A stochastic suboptimal controller, derived from optimal control theory, is defined and applied to ISWEC. Results of this approach have been compared with the ones obtained with a linear spring-damper controller, highlighting the capability to obtain a higher value of mean extracted power despite higher power peaks. PMID:25874267

  2. Stochastic Control of Inertial Sea Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Mattia Raffero

    2015-01-01

    Full Text Available The ISWEC (inertial sea wave energy converter is presented, its control problems are stated, and an optimal control strategy is introduced. As the aim of the device is energy conversion, the mean absorbed power by ISWEC is calculated for a plane 2D irregular sea state. The response of the WEC (wave energy converter is driven by the sea-surface elevation, which is modeled by a stationary and homogeneous zero mean Gaussian stochastic process. System equations are linearized thus simplifying the numerical model of the device. The resulting response is obtained as the output of the coupled mechanic-hydrodynamic model of the device. A stochastic suboptimal controller, derived from optimal control theory, is defined and applied to ISWEC. Results of this approach have been compared with the ones obtained with a linear spring-damper controller, highlighting the capability to obtain a higher value of mean extracted power despite higher power peaks.

  3. First Central and Eastern European Workshop on Quality control, patient dosimetry and radiation protection in diagnostic and interventional radiology and nuclear medicine

    International Nuclear Information System (INIS)

    National Frederic Joliot-Curie Research Institute for Radiobiology and Radiohygiene

    2007-01-01

    First Central and Eastern European Workshop on Quality Control, Patient Dosimetry and Radiation Protection in Diagnostic and Interventional Radiology and Nuclear Medicine, scientifically supported and accredited as a CPD event for medical physicists by EFOMP, National 'Frederic Joliot-Curie' Research Institute for Radiobiology and Radiohygiene (NRIRR), Budapest, Hungary, April 25-28, 2007. Topics of the meeting included all areas of medical radiation physics except radiation therapy. A unique possibility was realized by inviting four European manufacturers of quality control instrumentation, not only for exhibiting but they also had 45 minutes individual presentations about each manufacturer's product scale and conception. Further sessions dealt with dosimetry, optimization, quality control and testing, radiation protection and standardization, computed tomography and nuclear medicine, in 29 oral presentations and 1 poster of the participants. (S.I.)

  4. Energy saving by optimized controls for supermarket stores; Energie sparen mit optimierter Regeltechnik im Supermarkt

    Energy Technology Data Exchange (ETDEWEB)

    Wendelborn, Horst [Danfoss GmbH, Offenbach (Germany)

    2011-06-15

    Danfoss has been delivering for 20 years the optimizing ADAP-KOOL(R) control system. It enables the store to save 30% of the yearly energy bill, compared to a store with electronic standard controls. Over years the stores took the cheap standard solution, but now several German supermarket chains decide to take the best for the investment and lifecycle cost. This article describes the main control circuits and shows the measurements of the energy consumption of two stores with standard and optimized controls. This control system is available for chemical and for the natural refrigerant R744. (orig.)

  5. Application of fuzzy control in cooling systems save energy design

    Energy Technology Data Exchange (ETDEWEB)

    Chen, M.L.; Liang, H.Y. [Chienkuo Technology Univ., Changhua, Taiwan (China). Dept. of Electrical Engineering

    2005-07-01

    A fuzzy logic programmable logic controller (PLC) was used to control the cooling systems of frigorific equipment. Frigorific equipment is used to move unwanted heat outside of building in order to control indoor temperatures. The aim of the fuzzy logic PLC was to improve the energy efficiency of the cooling system. Control of the cooling pump and cooling tower in the system was based on the water temperature of the condenser during frigorific system operation. A human computer design for the cooling system control was used to set speeds and to automate and adjust the motor according to the fuzzy logic controller. It was concluded that if fuzzy logic controllers are used with all components of frigorific equipment, energy efficiency will be significantly increased. 5 refs., 3 tabs., 9 figs.

  6. Energy Efficient Engine: Control system preliminary definition report

    Science.gov (United States)

    Howe, David C.

    1986-01-01

    The object of the Control Preliminary Definition Program was to define a preliminary control system concept as a part of the Energy Efficient Engine program. The program was limited to a conceptual definition of a full authority digital electronic control system. System requirements were determined and a control system was conceptually defined to these requirements. Areas requiring technological development were identified and a plan was established for implementing the identified technological features, including a control technology demonstration. A significant element of this program was a study of the potential benefits of closed-loop active clearance control, along with laboratory tests of candidate clearance sensor elements for a closed loop system.

  7. Model Predictive Control of Buoy Type Wave Energy Converter

    DEFF Research Database (Denmark)

    Soltani, Mohsen N.; Sichani, Mahdi T.; Mirzaei, Mahmood

    2014-01-01

    by forcing this condition. In the paper the theoretical framework for this principal is shown. The optimal controller requires information of the sea state for infinite horizon which is not applicable. Model Predictive Controllers (MPC) can have finite horizon which crosses out this requirement....... This approach is then taken into account and an MPC controller is designed for a model wave energy converter and implemented on a numerical example. Further, the power outtake of this controller is compared to the optimal controller as an indicator of the performance of the designed controller....

  8. Radiological characterisation - Know your objective

    International Nuclear Information System (INIS)

    Lindow, Veronica; Moeller, Jennifer

    2012-01-01

    When developing a programme for mapping the radiological characteristics of a facility to be decommissioned it is important to take into account the objectives of the programme. Will the results be used to plan for radiological control and selection of appropriate decontamination and dismantling techniques? Will the radiological inventory be used for dimensioning of future waste repositories? These are two examples of the applications for such studies, which could require that a radiological characterisation programme be adapted to provide the data appropriate to the intended use. The level of detail and scope needed for a radiological characterisation will also vary depending on how the data will be used. An application to free-release a facility requires a comprehensive survey and well documented analysis in order to ensure that no radioactive contamination above prescribed levels is present. A bounding calculation to determine the maximum anticipated volumes and activity of radioactive waste requires a different approach. During the past few years, older decommissioning studies for the Swedish nuclear power plants have been updated (or are in the process of being updated). The decommissioning study's main purpose is to estimate the cost for decommissioning. The cost estimation is based on material and activity inventories, which in turn is based on previous and, in some cases, updated radiological characterisations of the facilities. The radiological inventory is an important part of the study as it affects the cost of decommissioning but also the uncertainties and accuracy of the cost estimation. The presentation will discuss the challenges in specifying a radiological characterisation programme with multiple objectives, together with insights on how data delivered can be applied to yield results suitable for the intended purpose, without introducing excessive conservatism. The intent of the presentation is to define issues that can be of use in various aspects

  9. Radiological safety aspects of industrial radiography

    International Nuclear Information System (INIS)

    Hanekom, A.P.

    1983-01-01

    Industrial radiography and especially gamma-radiography, has established itself as a very powerful tool in non-destructive testing. Unfortunately there is an amount of risk attached to the use of industrial radiography. The primary causes of radiography accidents include: working conditions, equipment failure and lack of supervisory control. To alleviate the radiological risks involved with gamma-radiography, the Atomic Energy Corporation (AEC) has imposed various conditions for the possession, use, and conveyance of radioactive material. This includes personnel training and equipment specifications

  10. Contemporary Targets for Control of Efficient Energy Use

    Directory of Open Access Journals (Sweden)

    Yu. S. Petrusha

    2012-01-01

    Full Text Available The paper describes main principles of the methodology for control of efficient energy use in power engineering and economy sectors as a whole. Targets for control of energy use at different levels have been considered in the paper. A special attention has been paid to technical, organizational and legal aspects of energy efficiency improvement. The paper contains an analysis of the history of the given issue, the present level of its development and near-term prospects under conditions of the Republic of Belarus.

  11. Radiological risk comparison guidelines

    International Nuclear Information System (INIS)

    Hallinan, E.J.; Muhlestein, L.D.; Brown, L.F.; Yoder, R.E.

    1992-01-01

    An important aspect of DOE safety analyses is estimating potential accident risk. The estimates are used to: determine if additional controls are needed, identify Safety Class Items, and demonstrate adequate risk reduction. Thus, guidelines are needed to measure comparative risks. The Westinghouse M ampersand O Nuclear Facility Safety Committee and the Safety Envelope Working Group have developed radiological risk guidelines for comparing the risks from individual accident analyses. These guidelines were prepared under contract with the US Department of Energy. These guidelines are based on historical DOE guidelines and current requirements, and satisfy DOE and technical community proposals. for goals that demonstrate acceptable risk. The guidelines consist of a frequency versus consequence curve for credible accidents. Offsite and onsite guidelines are presented. The offsite risk acceptance guidelines are presented in Figure 1. The guidelines are nearly isorisk for anticipated events where impacts are chronic, and provide additional reduction for unlikely events where impacts may be acute and risk uncertainties may be significant. The guidelines are applied to individual release accident scenarios where a discrete frequency and consequence has been estimated. The guideline curves are not to be used for total risk assessments. Common cause events are taken into consideration only for an individual facility. Frequencies outside the guideline range are considered to be local site option (analyst judgement) as far as assessments of risk acceptance are concerned. If the curve is exceeded, then options include either a more detailed analysis or imposing additional preventive or mitigative features. Another presentation discusses implementation in detail. Additional work is needed to provide risk comparison guidelines for releases from multiple facilities and for toxic releases

  12. Energy Storage System Control Algorithm by Operating Target Power to Improve Energy Sustainability of Smart Home

    Directory of Open Access Journals (Sweden)

    Byeongkwan Kang

    2018-01-01

    Full Text Available As energy issues are emerging around the world, a variety of smart home technologies aimed at realizing zero energy houses are being introduced. Energy storage system (ESS for smart home energy independence is increasingly gaining interest. However, limitations exist in that most of them are controlled according to time schedules or used in conjunction with photovoltaic (PV generation systems. In consideration of load usage patterns and PV generation of smart home, this study proposes an ESS control algorithm that uses constant energy of energy network while making maximum use of ESS. Constant energy means that the load consumes a certain amount of power under all conditions, which translates to low variability. The proposed algorithm makes a smart home a load of energy network with low uncertainty and complexity. The simulation results show that the optimal ESS operating target power not only makes the smart home use power constantly from the energy network, but also maximizes utilization of the ESS. In addition, since the smart home is a load that uses constant energy, it has the advantage of being able to operate an efficient energy network from the viewpoint of energy providers.

  13. Radiological findings in angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Schick, B. [Univ. of Marburg (Germany). Dept. of Ear, Nose and Throat Diseases; Kahle, G. [Univ. of Marburg, (Germany). Inst.of Radiology

    2000-11-01

    Surgery after pre-operative embolization has become the main treatment modality in angiofibroma therapy. As surgical planning is based on precise pre-operative tumour evaluation, knowledge of the characteristic growth patterns is of great interest. Analysis of tumour extension and blood supply, as well as methods of controlling intra-operative bleeding, help in determining the appropriate surgical approach. Though benign, angiofibroma demonstrates a locally aggressive nature. This fibrovascular tumour is characterised by typical radiological findings and by predictable growth patterns. The tumour extension and blood supply can be accurately determined by CT, MR imaging and angiography. With classic radiological findings, no pre-operative biopsy is necessary in most angiofibromas. Advances in radiological imaging have contributed to improved surgical planning and tumour resection. The surgeon is able to select the least traumatic approach with secure haemostatic control, which is also critical for avoiding the disturbance of facial skeletal growth in this group of young patients. Embolization, pre-operative autologous donation and the cell saver system for immediate retransfusion of the collected blood after filtration, are important tools for dealing with blood loss in angiofibroma surgery as they minimize homologous blood transfusion.

  14. Real Time Energy Management Control Strategies for Hybrid Powertrains

    Science.gov (United States)

    Zaher, Mohamed Hegazi Mohamed

    In order to improve fuel efficiency and reduce emissions of mobile vehicles, various hybrid power-train concepts have been developed over the years. This thesis focuses on embedded control of hybrid powertrain concepts for mobile vehicle applications. Optimal robust control approach is used to develop a real time energy management strategy for continuous operations. The main idea is to store the normally wasted mechanical regenerative energy in energy storage devices for later usage. The regenerative energy recovery opportunity exists in any condition where the speed of motion is in opposite direction to the applied force or torque. This is the case when the vehicle is braking, decelerating, or the motion is driven by gravitational force, or load driven. There are three main concepts for regernerative energy storing devices in hybrid vehicles: electric, hydraulic, and flywheel. The real time control challenge is to balance the system power demand from the engine and the hybrid storage device, without depleting the energy storage device or stalling the engine in any work cycle, while making optimal use of the energy saving opportunities in a given operational, often repetitive cycle. In the worst case scenario, only engine is used and hybrid system completely disabled. A rule based control is developed and tuned for different work cycles and linked to a gain scheduling algorithm. A gain scheduling algorithm identifies the cycle being performed by the machine and its position via GPS, and maps them to the gains.

  15. Safeness of radiological machinery

    International Nuclear Information System (INIS)

    Yokoyama, Shun

    1979-01-01

    The human factors affecting the safeness of radiological machinery, which are often very big and complicated machines, are described from the stand point of handling. 20 to 50% of the troubles on equipments seem to be caused by men. This percentage will become even higher in highly developed equipments. Human factors have a great influence on the safeness of radiological equipments. As the human factors, there are sensory factors and knowledge factors as well as psychological factors, and the combination of these factors causes mishandling and danger. Medical services at present are divided in various areas, and consist of the teamwork of the people in various professions. Good human relationship, education and control are highly required to secure the safeness. (Kobatake, H.)

  16. Westinghouse corporate development of a decision software program for Radiological Evaluation Decision Input (REDI)

    International Nuclear Information System (INIS)

    Bush, T.S.

    1995-01-01

    In December 1992, the Department of Energy (DOE) implemented the DOE Radiological Control Manual (RCM). Westinghouse Idaho Nuclear Company, Inc. (WINCO) submitted an implementation plan showing how compliance with the manual would be achieved. This implementation plan was approved by DOE in November 1992. Although WINCO had already been working under a similar Westinghouse RCM, the DOE RCM brought some new and challenging requirements. One such requirement was that of having procedure writers and job planners create the radiological input in work control procedures. Until this time, that information was being provided by radiological engineering or a radiation safety representative. As a result of this requirement, Westinghouse developed the Radiological Evaluation Decision Input (REDI) program

  17. Westinghouse corporate development of a decision software program for Radiological Evaluation Decision Input (REDI)

    Energy Technology Data Exchange (ETDEWEB)

    Bush, T.S. [Westinghosue Idaho Nuclear Co., Inc., Idaho Falls, ID (United States)

    1995-03-01

    In December 1992, the Department of Energy (DOE) implemented the DOE Radiological Control Manual (RCM). Westinghouse Idaho Nuclear Company, Inc. (WINCO) submitted an implementation plan showing how compliance with the manual would be achieved. This implementation plan was approved by DOE in November 1992. Although WINCO had already been working under a similar Westinghouse RCM, the DOE RCM brought some new and challenging requirements. One such requirement was that of having procedure writers and job planners create the radiological input in work control procedures. Until this time, that information was being provided by radiological engineering or a radiation safety representative. As a result of this requirement, Westinghouse developed the Radiological Evaluation Decision Input (REDI) program.

  18. Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Goldhagen, P.; Marino, S.A.; Randers-Pehrson, G.; Hall, E.J.

    1986-01-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which can be used to generate a variety of well-characterized radiation beams for research in radiobiology and radiological physics. It is part of the Radiological Research Laboratory (RRL), and its operation is supported as a National Facility by the US Department of Energy. RARAF is available to all potential users on an equal basis, with priorities based on the recommendations of a Scientific Advisory Committee. Facilities and services are provided to users, but the research projects themselves must be supported separately. This chapter presents a brief description of current experiments being carried out at RARAF and of the operation of the Facility from January through June, 1986. Operation of the Facility for all of 1985 was described in the 1985 Progress Report for RARAF. The experiments described here were supported by various Grants and Contracts from NIH and DOE and by the Statens Stralskyddsinstitut of Sweden

  19. Methodology for establishing of a control and assurance program on a Radiology Department of a university hospital

    International Nuclear Information System (INIS)

    Almeida, Carlos Domingues de; Almeida, Carlos Eduardo de

    1995-01-01

    The purpose of this work is to present a proposal of a quality assurance program developed for a typical diagnostic radiology department of a University Hospital. The aim of this program is to reduce the number of films lost due to several kinds of problems, equipment malfunction, incorrect selection of the physical parameters of the X-ray equipment, poor conditions of the film ecrans and chassis, excessive temperature fluctuations on the processor, personnel training and organizational related aspects. The preliminary results shows that the main causes of problems are film overexposure, film under exposure, unexposed films taken back to the dark room, inadequate positioning of the film in the couch, inadequate positioning of the patient and the X-ray processor in addition to others of minor importance. It is very important to emphasize that the data acquisition methodology must contemplate a professional posture of respect for those involved in the procedures and as result of this one would expect their active participation in the program. As result of the first year of study, this program has demonstrated that the annual losses in the department studied are over US$ 125.000,00 and the goal of this program now is to reduce this figure to an acceptable number, US$40.000,00 a reasonable value for a large diagnostic radiology facility. (author). 6 refs., 4 figs

  20. Power Converters and Control of Renewable Energy Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Teodorescu, Remus; Chen, Zhe

    2004-01-01

    The global electrical energy consumption is steadily rising and therefore a continuous demand to increase the power generation capacity. A significant percentage of the required capacity increase can be based on renewable energy sources. Wind turbine technology, as the most cost effective renewable...... energy conversion system, will play an important part in our future energy supply. But other sources like microturbines, photovoltaics and fuel cell systems may also be serious contributor to the power supply. Characteristically, power electronics will be an efficient and important interface to the grid...... for the renewables and this paper will first briefly discuss three different alternative/renewable energy sources. Next, various configurations of small and medium power conversion topologies are presented including their control (mainly for PV-systems). Finally wind turbine configuration and their control...

  1. Implementation of Energy Code Controls Requirements in New Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hatten, Mike [Solarc Energy Group, LLC, Seattle, WA (United States); Jones, Dennis [Group 14 Engineering, Inc., Denver, CO (United States); Cooper, Matthew [Group 14 Engineering, Inc., Denver, CO (United States)

    2017-03-24

    Most state energy codes in the United States are based on one of two national model codes; ANSI/ASHRAE/IES 90.1 (Standard 90.1) or the International Code Council (ICC) International Energy Conservation Code (IECC). Since 2004, covering the last four cycles of Standard 90.1 updates, about 30% of all new requirements have been related to building controls. These requirements can be difficult to implement and verification is beyond the expertise of most building code officials, yet the assumption in studies that measure the savings from energy codes is that they are implemented and working correctly. The objective of the current research is to evaluate the degree to which high impact controls requirements included in commercial energy codes are properly designed, commissioned and implemented in new buildings. This study also evaluates the degree to which these control requirements are realizing their savings potential. This was done using a three-step process. The first step involved interviewing commissioning agents to get a better understanding of their activities as they relate to energy code required controls measures. The second involved field audits of a sample of commercial buildings to determine whether the code required control measures are being designed, commissioned and correctly implemented and functioning in new buildings. The third step includes compilation and analysis of the information gather during the first two steps. Information gathered during these activities could be valuable to code developers, energy planners, designers, building owners, and building officials.

  2. Energy efficient topology control algorithm for wireless mesh networks

    CSIR Research Space (South Africa)

    Aron, FO

    2008-08-01

    Full Text Available The control of the topology of a network makes it possible for the network nodes to reduce their power of transmission while ensuring that network connectivity is preserved. This paper explains the need for energy consumption control in Wireless...

  3. Gate controlled high efficiency ballistic energy conversion system

    NARCIS (Netherlands)

    Xie, Yanbo; Bos, Diederik; de Boer, Hans L.; van den Berg, Albert; Eijkel, Jan C.T.; Zengerle, R.

    2013-01-01

    Last year we demonstrated the microjet ballistic energy conversion system[1]. Here we show that the efficiency of such a system can be further improved by gate control. With gate control the electrical current generation is enhanced a hundred times with respect to the current generated from the zeta

  4. Hypothalamic control of energy metabolism via the autonomic nervous system

    NARCIS (Netherlands)

    Kalsbeek, A.; Bruinstroop, E.; Yi, C. X.; Klieverik, L. P.; La Fleur, S. E.; Fliers, E.

    2010-01-01

    The hypothalamic control of hepatic glucose production is an evident aspect of energy homeostasis. In addition to the control of glucose metabolism by the circadian timing system, the hypothalamus also serves as a key relay center for (humoral) feedback information from the periphery, with the

  5. Energy-Based Controller Design of Stochastic Magnetic Levitation System

    Directory of Open Access Journals (Sweden)

    Weiwei Sun

    2017-01-01

    Full Text Available This paper investigates the control problem of magnetic levitation system, in which velocity feedback signal is influenced by stochastic disturbance. Firstly, single-degree-freedom magnetic levitation is regarded as an energy-transform action device. From the view of energy-balance relation, the magnetic levitation system is transformed into port-controlled Hamiltonian system model. Next, based on the Hamiltonian structure, the control law of magnetic levitation system is designed by applying Lyapunov theory. Finally, the simulation verifies the correctness of the proposed results.

  6. Helicopter Control Energy Reduction Using Moving Horizontal Tail

    Science.gov (United States)

    Oktay, Tugrul; Sal, Firat

    2015-01-01

    Helicopter moving horizontal tail (i.e., MHT) strategy is applied in order to save helicopter flight control system (i.e., FCS) energy. For this intention complex, physics-based, control-oriented nonlinear helicopter models are used. Equations of MHT are integrated into these models and they are together linearized around straight level flight condition. A specific variance constrained control strategy, namely, output variance constrained Control (i.e., OVC) is utilized for helicopter FCS. Control energy savings due to this MHT idea with respect to a conventional helicopter are calculated. Parameters of helicopter FCS and dimensions of MHT are simultaneously optimized using a stochastic optimization method, namely, simultaneous perturbation stochastic approximation (i.e., SPSA). In order to observe improvement in behaviors of classical controls closed loop analyses are done. PMID:26180841

  7. Helicopter Control Energy Reduction Using Moving Horizontal Tail

    Directory of Open Access Journals (Sweden)

    Tugrul Oktay

    2015-01-01

    Full Text Available Helicopter moving horizontal tail (i.e., MHT strategy is applied in order to save helicopter flight control system (i.e., FCS energy. For this intention complex, physics-based, control-oriented nonlinear helicopter models are used. Equations of MHT are integrated into these models and they are together linearized around straight level flight condition. A specific variance constrained control strategy, namely, output variance constrained Control (i.e., OVC is utilized for helicopter FCS. Control energy savings due to this MHT idea with respect to a conventional helicopter are calculated. Parameters of helicopter FCS and dimensions of MHT are simultaneously optimized using a stochastic optimization method, namely, simultaneous perturbation stochastic approximation (i.e., SPSA. In order to observe improvement in behaviors of classical controls closed loop analyses are done.

  8. Stochastic control applied to the ISWEC Wave Energy System

    International Nuclear Information System (INIS)

    Bracco, Giovanni; Casassa, Maria; Giorcelli, Ermanno; Mattiazzo, Giuliana; Passione, Biagio; Raffero, Mattia; Vissio, Giacomo; Martini, Michele

    2015-01-01

    ISWEC (Inertial Sea Wave Energy Converter) is a floating marine device able to harvest sea waves energy by the interaction between the pitching motion of a floater and a spinning flywheel which can drive an electric PTO. In the ISWEC the hull dynamics is governed and controlled by the gyroscopic torque. The optimal control logic results in tuning the floater dynamics to the incoming waves in order to maximize the power transfer from the waves to the floater. In this paper the control problems of the ISWEC are stated and a control scheme based on the sub-optimal stochastic control logic is presented. The control scheme here presented has been tested using real wave records acquired at the deployment location in Pantelleria Island, which is one of the most energetic sites of the Mediterranean Sea.

  9. Radiologic protection in dental radiology

    International Nuclear Information System (INIS)

    Pacheco Jimenez, R.E.; Bermudez Jimenez, L.A.

    2000-01-01

    With this work and employing the radioprotection criterion, the authors pretend to minimize the risks associated to this practice; without losing the quality of the radiologic image. Odontology should perform the following criterions: 1. Justification: all operation of practice that implies exposition to radiations, should be reweighed, through an analysis of risks versus benefits, with the purpose to assure, that the total detriment will be small, compared to resultant benefit of this activity. 2. Optimization: all of the exposures should be maintained as low as reasonable possible, considering the social and economic factors. 3. Dose limit: any dose limit system should be considered as a top condition, nota as an admissible level. (S. Grainger)

  10. Energy Efficient Pump Control for an Offshore Oil Processing System

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Soleiman, Kian; Løhndorf, Bo

    2012-01-01

    The energy efficient control of a pump system for an offshore oil processing system is investigated. The seawater is lifted up by a pump system which consists of three identical centrifugal pumps in parallel, and the lifted seawater is used to cool down the crude oil flowing out of a threephase...... separator on one of the Danish north-sea platform. A hierarchical pump-speed control strategy is developed for the considered system by minimizing the pump power consumption subject to keeping a satisfactory system performance. The proposed control strategy consists of online estimation of some system...... operating parameters, optimization of pump configurations, and a real-time feedback control. Comparing with the current control strategy at the considered system, where the pump system is on/off controlled, and the seawater flows are controlled by a number of control valves, the proposed control strategy...

  11. Training in radiological protection: Curricula and programming

    International Nuclear Information System (INIS)

    1964-01-01

    An important activity of the International Atomic Energy Agency is the promotion of training in radiological protection. Through its organized training courses, its fellowship training programme and its field experts, the Agency has assisted many Member States to train an essential group of scientists in radiological protection. Many Member States are now developing their own national training programmes in radiological protection and this report has been prepared to provide the guidance that may be required in this development. In the report the various types of training which are encountered in a radiological protection programme are fully discussed, curricula are suggested and examples of established training courses are annexed

  12. Control systems in the intersection of energy and ICT industries

    Energy Technology Data Exchange (ETDEWEB)

    Hellsten, K.; Kaessi, T.; Mustonen, T.; Paetaeri, S.; Soininen, L.

    2008-07-01

    The main objective of this research report is to shed light on business possibilities that are related to monitoring and control systems in the intersection of energy and ICT industries. The study uses both primary and secondary data sources that include a qualitative Delphi study, themed interviews, idea generation session, quantitative data regarding the alliances between the energy and ICT sectors as well as relevant literature. The environmental issues, the availability of energy, the opening energy markets, modern distributed generation and the saturation of existing transmission and distribution grids have raised a need to develop new energy solutions and business activities based on them. At the same time, the fast development in ICT technologies and automation has offered better possibilities for their implementation. Thus, the external factors and demands posed e.g. by political and social quarters as well as the internal needs of the energy companies make the cooperation in the intersection necessary and elaborate. The report reveals two major areas for the development of the cooperation between the energy and ICT sectors: households' energy utilization and distributed energy generation. In the former theme, e.g. the follow-up and guidance of energy consumption as well as new ways of electricity purchasing came up as issues for further examination. As regards to the second theme, the distributed energy solutions are seen to increase unavoidably and forcefully in the future. The emergence of distributed generation poses many new challenges for the whole energy system but also a vast amount of opportunities for the two sectors' co-operative activities, as the interfaces between the small local units and networks and the centralized system need to be controlled effectively and legitimately. (orig.)

  13. Radiological health review of the Draft Environmental Impact Statement (DOE/EIS-0026-D) Waste Isolation Pilot Plant, US Department of Energy. Report EEG-3

    International Nuclear Information System (INIS)

    Neill, R.H.; Channell, J.K.; Wofsy, C.; Greenfield, M.A.

    1979-08-01

    This review of radiological health considerations contains a number of concerns, questions and recommendations that should be addressed by the Department of Energy in the final Environmental Impact Statement (EIS) for the Waste Isolation Pilot Plant (WIPP). Using the assumptions contained in the Draft Environmental Impact Statement (DEIS), the Environmental Evaluation Group (EEG) calculated a number of radiation doses and the results were found to be in general agreement with those presented in the DEIS. The doses resulting from the operational and long-range releases from WIPP to the general population are no more than a fraction of existing radiation doses to the public. However, there are a number of technical considerations in the assessment of radiation exposure that were not adequately evaluated in the DEIS. They are discussed in this review. A number of additional dosage estimates have been identified that need to be calculated by both DOE and EEG. As the DEIS did not contain estimates of the amounts of radioactivity to be permanently located in the repository, it was necessary to calculate these amounts. Health effects, transportation, waste acceptance criteria, site evaluation, site selection criteria, operational exposure, the experimental waste program, long term radiation releases, retrievability, and decommissioning are the categories of the DEIS which were evaluated

  14. Radiological diagnosis of osteoporosis

    International Nuclear Information System (INIS)

    Heuck, F.H.W.

    1990-01-01

    The roentgen-morphologic findings of 'osteoporosis' in the different regions of the skeleton are demonstrated. A combination of osteoporosis and osteomalacia induced by hormonal and metabolic bone diseases occur frequently. The results of sequential studies are discussed. Diagnostic informations obtained by quantitative radiology, especially by different methods like x-ray morphometry, densitometry with gamma-rays of isotopes of different energies, quantitative computed tomography, and imaging analysis with electronic methods are described. The sequential use of diagnostic imaging techniques in cases of suspected osteoporosis are explained. (Author)

  15. Insulin controls food intake and energy balance via NPY neurons

    Directory of Open Access Journals (Sweden)

    Kim Loh

    2017-06-01

    Full Text Available Objectives: Insulin signaling in the brain has been implicated in the control of satiety, glucose homeostasis and energy balance. However, insulin signaling is dispensable in energy homeostasis controlling AgRP or POMC neurons and it is unclear which other neurons regulate these effects. Here we describe an ancient insulin/NPY neuronal network that governs energy homeostasis across phyla. Methods: To address the role of insulin action specifically in NPY neurons, we generated a variety of models by selectively removing insulin signaling in NPY neurons in flies and mice and testing the consequences on energy homeostasis. Results: By specifically targeting the insulin receptor in both fly and mouse NPY expressing neurons, we found NPY-specific insulin signaling controls food intake and energy expenditure, and lack of insulin signaling in NPY neurons leads to increased energy stores and an obese phenotype. Additionally, the lack of insulin signaling in NPY neurons leads to a dysregulation of GH/IGF-1 axis and to altered insulin sensitivity. Conclusions: Taken together, these results suggest that insulin actions in NPY neurons is critical for maintaining energy balance and an impairment of this pathway may be causally linked to the development of metabolic diseases. Keywords: Hypothalamus, NPY, Insulin, Obesity

  16. Real-Time Energy Management Control for Hybrid Electric Powertrains

    Directory of Open Access Journals (Sweden)

    Mohamed Zaher

    2013-01-01

    Full Text Available This paper focuses on embedded control of a hybrid powertrain concepts for mobile vehicle applications. Optimal robust control approach is used to develop a real-time energy management strategy. The main idea is to store the normally wasted mechanical regenerative energy in energy storage devices for later usage. The regenerative energy recovery opportunity exists in any condition where the speed of motion is in the opposite direction to the applied force or torque. This is the case when the vehicle is braking, decelerating, the motion is driven by gravitational force, or load driven. There are three main concepts for energy storing devices in hybrid vehicles: electric, hydraulic, and mechanical (flywheel. The real-time control challenge is to balance the system power demands from the engine and the hybrid storage device, without depleting the energy storage device or stalling the engine in any work cycle. In the worst-case scenario, only the engine is used and the hybrid system is completely disabled. A rule-based control algorithm is developed and is tuned for different work cycles and could be linked to a gain scheduling algorithm. A gain scheduling algorithm identifies the cycle being performed by the work machine and its position via GPS and maps both of them to the gains.

  17. NNSA/NV Consequence Management Capabilities for Radiological Emergency Response

    International Nuclear Information System (INIS)

    Bowman, D. R.

    2002-01-01

    The U.S. Department of Energy's National Nuclear Security Administration Nevada Operations Office (NNSA/NV) provides an integrated Consequence Management (CM) response capability for the (NNSA) in the event of a radiological emergency. This encompasses planning, technical operations, and home team support. As the lead organization for CM planning and operations, NNSA/NV coordinates the response of the following assets during the planning and operational phases of a radiological accident or incident: (1) Predictive dispersion modeling through the Atmospheric Release Advisory Capability (ARAC) at Lawrence Livermore National Laboratory (LLNL) and the High Consequence Assessment Group at Sandia National Laboratories (SNL); (2) Regional radiological emergency assistance through the eight Radiological Assistance Program (RAP) regional response centers; (3) Medical advice and assistance through the Radiation Emergency Assistance Center/Training Site (REAC/TS) in Oak Ridge, Tennessee; (4) Aerial radiological mapping using the fixed-wing and rotor-wing aircraft of the Aerial Measuring System (AMS); (5) Consequence Management Planning Teams (CMPT) and Consequence Management Response Teams (CMRT) to provide CM field operations and command and control. Descriptions of the technical capabilities employed during planning and operations are given below for each of the elements comprising the integrated CM capability

  18. Current radiology. Volume 5

    International Nuclear Information System (INIS)

    Wilson, G.H.; Hanafee, W.N.

    1984-01-01

    This book contains 10 selections. They are: Nuclear Magnetic Resonance Imaging, Interventional Vascular Radiology, Genitourinary Radiology, Skeletal Radiology, Digital Subtraction Angiography, Neuroradiology, Computed Tomographic Evaluation of Degenerative Diseases of the Lumbar Spine, The Lung, Otolaringology and Opthalmology, and Pediatric Radiology: Cranial, Facial, Cervical, Vertebral, and Appendicular

  19. Mobile Radiological Laboratories Intercomparison Measurements - Chernobyl

    International Nuclear Information System (INIS)

    Martincic, R.; Glavic-Cindro, D.; Korun, M.; Pucelj, B.; Vodenik, B.

    2001-01-01

    Full text: In last decade different institutions in European countries have organised periodic intercomparison exercises of mobile radiological laboratories to improve the preparedness of emergency monitoring teams. The 12th Regular Workshop on Mobile Radiological Laboratories was held in Exclusion Zone of the Chernobyl NPP, Ukraine from September 13 to September 18, 1999 under the acronym MORAL-12. The European Centre of Technological Safety (TESEC), Kiev, Ukraine and J. Stefan Institute, Ljubljana, Slovenia organised Intercomparison Measurements 99 jointly under the auspices of the International Atomic Energy Agency (IAEA). Nineteen teams from 9 countries and IAEA participated in the Workshop. Six field and personal and equipment contamination control exercises were prepared and conducted at two measuring sites with very different ambient dose rate levels. The Workshop pointed out that such exercises are very valuable for rapid, efficient and harmonised emergency response in case of nuclear or radiological emergency. The teams had an opportunity to test their ability to perform field measurements in the contaminated environment, and to report results on the spot, as well as to test their emergency preparedness and persistence. They gained new experiences for fieldwork under stress conditions. An overview and results of these intercomparison measurements are presented and lessons learned are discussed. (author)

  20. Characterisation, control, and energy management of electrified turbocharged diesel engines

    International Nuclear Information System (INIS)

    Zhao, Dezong; Winward, Edward; Yang, Zhijia; Stobart, Richard; Steffen, Thomas

    2017-01-01

    Highlights: • A real-time energy management framework for electrified engines is proposed. • A multi-variable robust controller is designed. • Characterisation on the air system of electrified diesel engines is given. • Reliable for engine downsizing because of the promising transient performance. - Abstract: The electrification of engine components offers significant opportunities for fuel efficiency improvements. The electrified turbocharger is one of the most attractive options since it recovers part of the engine exhaust gas mechanical energy to assist boosting. Therefore, the engine can be downsized through improved transient responsiveness. In the electrified turbocharger, an electric machine is mounted on the turbine shaft and changes the air system dynamics, so characterisation of the new layout is essential. A systematic control solution is required to manage energy flows in the hybrid system. In this paper, a framework for characterisation, control, and energy management for an electrified turbocharged diesel engine is proposed. The impacts of the electric machine on fuel economy and air system variables are analysed. Based on the characterisation, a two-level control structure is proposed. A real-time energy management strategy is employed as the supervisory level controller to generate the optimal values of critical variables, while a model-based multi-variable controller is designed as the low level controller to track the values. The two controllers work together in a cascade to address both fuel economy optimisation and battery state-of-charge maintenance. The proposed control strategy is validated on a high fidelity physical engine model. The tracking performance shows the proposed framework is a promising solution in regulating the behavior of electrified engines.

  1. Cycle energy control of magnetorheological dampers on cables

    International Nuclear Information System (INIS)

    Weber, F; Feltrin, G; Motavalli, M; Distl, H

    2009-01-01

    The dissipated cycle energy of magnetorheological (MR) dampers operated at constant current results from controllable hysteretic damping and from almost current independent, small viscous damping. Thus, the emulation of Coulomb friction and linear viscous damping necessitates current modulation during one vibration cycle and therefore current drivers. To avoid this drawback, a cycle energy control (CEC) approach is presented which controls the hysteretic MR damper part such that the total MR damper energy equals the energy of optimal linear viscous damping by constant current during one cycle. The excited higher modes due to the hysteretic damping part are partially damped by the MR damper viscous part. Simulations show that CEC copes better with damper force dynamics and constraints than emulated linear viscous damping due to the slow control force dynamics of CEC which are given by cable amplitude dynamics. It is demonstrated that CEC of MR dampers with viscosity of approximately 4.65% of the optimal modal viscosity performs better than optimal linear viscous damping. The reason is that this damper viscosity represents an optimal compromise between maximum energy spillover to higher modes due to the controllable hysteretic part which produces more cable damping and maximum viscous damping of these higher modes. Damping tests on a cable with an MR damper validate the CEC approach

  2. Radiological Work Planning and Procedures

    International Nuclear Information System (INIS)

    KURTZ, J.E.

    2000-01-01

    Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In addition, there seems to be confusion as to what should be and what should not be included in the TWD

  3. Safety aspects in radiology

    International Nuclear Information System (INIS)

    Silva, D.C. da.

    1991-05-01

    The development of a program for the evaluation of the physical installations and operational procedures in diagnostic radiology with respect to radiation-safety is described. In addition, a proposal for the quality analysis of X-ray equipment and film-processing is presented. The purpose is both to ensure quality and safety of the radiology service, as well as to aid in the initial and in-service training of the staff. Interviews with patients, staff practicing radiology at a wide range of levels and the controlling authorities were carried out in the State of Rio de Janeiro in order to investigate the existence and the effective use of personal radioprotection equipment as well as user's and staff's concern for radiation safety. Additionally physical measurements were carried out in University Hospitals in Rio de Janeiro to assess the quality of equipment in day-to-day use. It was found that in the locations which did not have routine maintenance the equipment was generally in a poor state which lead to a high incidence of repetition of examinations and the consequent financial loss. (author)

  4. Potential energy consumption reduction of automotive climate control systems

    International Nuclear Information System (INIS)

    Nielsen, Filip; Uddheim, Åsa; Dalenbäck, Jan-Olof

    2016-01-01

    Highlights: • Twenty-on energy saving measures for vehicle interior climate were evaluated. • Few single energy saving measures could reduce the energy use significantly. • The operation of the system in intermediate conditions determines the energy use. • Required heating/cooling of passenger compartment had small effect on energy use. - Abstract: In recent years fuel consumption of passenger vehicles has received increased attention by customers, the automotive industry, regulatory agencies and academia. One area which affect the fuel consumption is climate control systems. Twenty-one energy saving measures were evaluated regarding the total energy use for vehicle interior climate using simulation. Evaluated properties were heat flow into the passenger compartment, electrical and mechanical work. The simulation model included sub models of the passenger compartment, air-handling unit, Air Conditioning (AC) system, engine and engine cooling system. A real-world representative test cycle, which included tests in cold, intermediate and warm conditions, was used for evaluation. In general, few single energy saving measures could reduce the energy use significantly. The measures with most potential were increased blower efficiency with a reduction of 46% of the electrical work and increased AC-system disengage temperature with a reduction of 27% of the mechanical work. These results show that the operation of the climate control system had a large effect on the energy use, especially compared to the required heating and cooling of the passenger compartment. As a result energy saving measures need to address how heating and cooling is generated before reducing the heat flow into the passenger compartment.

  5. Feedback Linearization Controller for a Wind Energy Power System

    Directory of Open Access Journals (Sweden)

    Muthana Alrifai

    2016-09-01

    Full Text Available This paper deals with the control of a doubly-fed induction generator (DFIG-based variable speed wind turbine power system. A system of eight ordinary differential equations is used to model the wind energy conversion system. The generator has a wound rotor type with back-to-back three-phase power converter bridges between its rotor and the grid; it is modeled using the direct-quadrature rotating reference frame with aligned stator flux. An input-state feedback linearization controller is proposed for the wind energy power system. The controller guarantees that the states of the system track the desired states. Simulation results are presented to validate the proposed control scheme. Moreover, further simulation results are shown to investigate the robustness of the proposed control scheme to changes in some of the parameters of the system.

  6. Stochastic Control of Energy Efficient Buildings: A Semidefinite Programming Approach

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Xiao [ORNL; Dong, Jin [ORNL; Djouadi, Seddik M [ORNL; Nutaro, James J [ORNL; Kuruganti, Teja [ORNL

    2015-01-01

    The key goal in energy efficient buildings is to reduce energy consumption of Heating, Ventilation, and Air- Conditioning (HVAC) systems while maintaining a comfortable temperature and humidity in the building. This paper proposes a novel stochastic control approach for achieving joint performance and power control of HVAC. We employ a constrained Stochastic Linear Quadratic Control (cSLQC) by minimizing a quadratic cost function with a disturbance assumed to be Gaussian. The problem is formulated to minimize the expected cost subject to a linear constraint and a probabilistic constraint. By using cSLQC, the problem is reduced to a semidefinite optimization problem, where the optimal control can be computed efficiently by Semidefinite programming (SDP). Simulation results are provided to demonstrate the effectiveness and power efficiency by utilizing the proposed control approach.

  7. Monitoring and control of a hybrid energy system

    International Nuclear Information System (INIS)

    Raceanu, M.; Culcer, M.; Patularu, L.; Enache, A.; Balan, M.; Varlam, M.

    2010-01-01

    Full text: This article presents monitoring and control of a Hybrid Energy System (HES). The HES is composed of six main components: solar panels, electrolyzer, fuel cells stack, charge controller, DC-AC inverter and lead acid batteries. Solar panels function as the primary source of energy, converting the energy from the sun into electricity that is given to a DC bus. Electrolyzer is a device that produces hydrogen and oxygen from the water following a process electrochemical. When there is excess energy from solar panels, electrolyzer is switched to produce hydrogen which is stored in hydrogen tank. Hydrogen produced is used by an assembly of fuel cell; this produces electricity that is transmitted on the DC bus, using hydrogen produced by electrolysis. Can be measured and displayed in real time data including, voltage, current, flow of hydrogen from the fuel cell, voltage, current, temperature of the photovoltaic panels, pressure hydrogen from electrolysis, pressure hydrogen tank and battery voltage. The control system is designed according to state of charge (SoC) of the battery. Are presented control strategy which ensures the On/Off control of the electrolyzer, to consume electricity from the battery and to generate electricity from fuel cells. The system hardware consists of an acquisition board, communication system of type CAN, sensors and interface devices. Monitoring and control software was developed in LabView 9.0. (authors)

  8. Training in radiological protection

    International Nuclear Information System (INIS)

    Medina G, E.

    2014-08-01

    In the Peru, according to the current regulations, people that work with ionizing radiations should have an authorization (individual license), which is granted by the Technical Office of the National Authority that is the technical body of the Instituto Peruano de Energia Nuclear (IPEN) manager of the control of ionizing radiations in the country. The individual license is obtained after the applicant fulfills the requested requirements, as having safety knowledge and radiological protection. Since its founding in 1972, the Centro Superior de Estudios Nucleares (CSEN) of the IPEN has carried out diverse training courses in order to that people can work in a safe way with ionizing radiations in medicine, industry and research, until the year 2013 have been organized 2231 courses that have allowed the training of 26213 people. The courses are organized according to the specific work that is carried out with radiations (medical radio-diagnostic, dental radiology, nuclear medicine, radiotherapy, industrial radiography, nuclear meters, logging while drilling, etc.). In their majority the courses are directed to people that will make use of radiations for first time, but refresher courses are also granted in the topic. The CSEN also carries out the Master degree programs highlighting the Second Professional Specialization in Radiological Protection carried out from the year 2004 with the support of the National University of Engineering. To the present has been carried out 2 programs and there is other being developed. In this work is shown the historical evolution of the radiological protection courses as well as the important thing that they are to work in a safe way in the country. (Author)

  9. Energy management and multi-layer control of networked microgrids

    Science.gov (United States)

    Zamora, Ramon

    Networked microgrids is a group of neighboring microgrids that has ability to interchange power when required in order to increase reliability and resiliency. Networked microgrid can operate in different possible configurations including: islanded microgrid, a grid-connected microgrid without a tie-line converter, a grid-connected microgrid with a tie-line converter, and networked microgrids. These possible configurations and specific characteristics of renewable energy offer challenges in designing control and management algorithms for voltage, frequency and power in all possible operating scenarios. In this work, control algorithm is designed based on large-signal model that enables microgrid to operate in wide range of operating points. A combination between PI controller and feed-forward measured system responses will compensate for the changes in operating points. The control architecture developed in this work has multi-layers and the outer layer is slower than the inner layer in time response. The main responsibility of the designed controls are to regulate voltage magnitude and frequency, as well as output power of the DG(s). These local controls also integrate with a microgrid level energy management system or microgrid central controller (MGCC) for power and energy balance for. the entire microgrid in islanded, grid-connected, or networked microgid mode. The MGCC is responsible to coordinate the lower level controls to have reliable and resilient operation. In case of communication network failure, the decentralized energy management will operate locally and will activate droop control. Simulation results indicate the superiority of designed control algorithms compared to existing ones.

  10. Hybrid photovoltaic system control for enhancing sustainable energy. Economic aspects

    International Nuclear Information System (INIS)

    Leva, Sonia; Roscia, Mariacristina; Zaninelli, Dario

    2005-01-01

    The paper introduces hybrid photovoltaic/diesel generation systems for supplying remote power plant taking into account the enhancement of sustainable energy on the economic point of view. In particular, a new monitoring and control device is presented in order to carry out the optimum energy flows and a cost evaluation is performed on a real plant showing the effect and weight of the economical sustainability and economical saving. (authors)

  11. Robust Control of Aeronautical Electrical Generators for Energy Management Applications

    OpenAIRE

    Giacomo Canciello; Alberto Cavallo; Beniamino Guida

    2017-01-01

    A new strategy for the control of aeronautical electrical generators via sliding manifold selection is proposed, with an associated innovative intelligent energy management strategy used for efficient power transfer between two sources providing energy to aeronautical loads, having different functionalities and priorities. Electric generators used for aeronautical application involve several machines, including a main generator and an exciter. Standard regulators (PI or PID-like) are normally...

  12. Stochastic Model Predictive Control with Applications in Smart Energy Systems

    DEFF Research Database (Denmark)

    Sokoler, Leo Emil; Edlund, Kristian; Mølbak, Tommy

    2012-01-01

    to cover more than 50% of the total consumption by 2050. Energy systems based on significant amounts of renewable energy sources are subject to uncertainties. To accommodate the need for model predictive control (MPC) of such systems, the effect of the stochastic effects on the constraints must...... study, we consider a system consisting of fuel-fired thermal power plants, wind farms and electric vehicles....

  13. Sensorless Estimation and Nonlinear Control of a Rotational Energy Harvester

    Science.gov (United States)

    Nunna, Kameswarie; Toh, Tzern T.; Mitcheson, Paul D.; Astolfi, Alessandro

    2013-12-01

    It is important to perform sensorless monitoring of parameters in energy harvesting devices in order to determine the operating states of the system. However, physical measurements of these parameters is often a challenging task due to the unavailability of access points. This paper presents, as an example application, the design of a nonlinear observer and a nonlinear feedback controller for a rotational energy harvester. A dynamic model of a rotational energy harvester with its power electronic interface is derived and validated. This model is then used to design a nonlinear observer and a nonlinear feedback controller which yield a sensorless closed-loop system. The observer estimates the mechancial quantities from the measured electrical quantities while the control law sustains power generation across a range of source rotation speeds. The proposed scheme is assessed through simulations and experiments.

  14. CNS-targets in control of energy and glucose homeostasis.

    Science.gov (United States)

    Kleinridders, André; Könner, A Christine; Brüning, Jens C

    2009-12-01

    The exceeding efforts in understanding the signals initiated by nutrients and hormones in the central nervous system (CNS) to regulate glucose and energy homeostasis have largely revolutionized our understanding of the neurocircuitry in control of peripheral metabolism. The ability of neurons to sense nutrients and hormones and to adopt a coordinated response to these signals is of crucial importance in controlling food intake, energy expenditure, glucose and lipid metabolism. Anatomical lesion experiments, pharmacological inhibition of signaling pathways, and, more recently, the analysis of conditional mouse mutants with modifications of hormone and nutrient signaling in defined neuronal populations have broadened our understanding of these complex neurocircuits. This review summarizes recent findings regarding the role of the CNS in sensing and transmitting nutritional and hormonal signals to control energy and glucose homeostasis and aims to define them as potential novel drug targets for the treatment of obesity and type 2 diabetes mellitus.

  15. Model Predictive Control of a Wave Energy Converter

    DEFF Research Database (Denmark)

    Andersen, Palle; Pedersen, Tom Søndergård; Nielsen, Kirsten Mølgaard

    2015-01-01

    In this paper reactive control and Model Predictive Control (MPC) for a Wave Energy Converter (WEC) are compared. The analysis is based on a WEC from Wave Star A/S designed as a point absorber. The model predictive controller uses wave models based on the dominating sea states combined with a model...... connecting undisturbed wave sequences to sequences of torque. Losses in the conversion from mechanical to electrical power are taken into account in two ways. Conventional reactive controllers are tuned for each sea state with the assumption that the converter has the same efficiency back and forth. MPC...

  16. Power Control Optimization of an Underwater Piezoelectric Energy Harvester

    Directory of Open Access Journals (Sweden)

    Iñigo Aramendia

    2018-03-01

    Full Text Available Over the past few years, it has been established that vibration energy harvesters with intentionally designed components can be used for frequency bandwidth enhancement under excitation for sufficiently high vibration amplitudes. Pipelines are often necessary means of transporting important resources such as water, gas, and oil. A self-powered wireless sensor network could be a sustainable alternative for in-pipe monitoring applications. A new control algorithm has been developed and implemented into an underwater energy harvester. Firstly, a computational study of a piezoelectric energy harvester for underwater applications has been studied for using the kinetic energy of water flow at four different Reynolds numbers Re = 3000, 6000, 9000, and 12,000. The device consists of a piezoelectric beam assembled to an oscillating cylinder inside the water of pipes from 2 to 5 inches in diameter. Therefore, unsteady simulations have been performed to study the dynamic forces under different water speeds. Secondly, a new control law strategy based on the computational results has been developed to extract as much energy as possible from the energy harvester. The results show that the harvester can efficiently extract the power from the kinetic energy of the fluid. The maximum power output is 996.25 µW and corresponds to the case with Re = 12,000.

  17. Pulse energy control through dual loop electronic feedback

    CSIR Research Space (South Africa)

    Jacobs, Cobus

    2006-07-01

    Full Text Available University of Stellenbosch WWW.LASER-RESEARCH.CO.ZA University of Stellenbosch Pulse Energy Control Through Dual Loop Electronic Feedback Cobus Jacobs, Steven Kriel Christoph Bollig, Thomas Jones Cobus Jacobs et al. Overview head2righthead2right...What is Laser Pulse Energy Control? head2righthead2rightWhy do we need it? head2righthead2rightHow do we get it? head2righthead2rightSimulation head2righthead2rightExperimental Setup head2righthead2rightResults Cobus Jacobs et al. head2righthead2right...

  18. UY 100 standard basic regulation of protection and radiological safety: approve by Industry Energy and Mining Ministry 28/6/2002 Resolution

    International Nuclear Information System (INIS)

    2002-01-01

    The following standard studies basic purposes of the radiological protection,practices classification, required for authorization in nuclear installations, equipment and radiation sources to grant permission, occupational, medical, and public exposition, and emergency plans

  19. Energy efficient motion control of the electric bus on route

    Science.gov (United States)

    Kotiev, G. O.; Butarovich, D. O.; Kositsyn, B. B.

    2018-02-01

    At present, the urgent problem is the reduction of energy costs of urban motor transport. The article proposes a method of solving this problem by developing an energy-efficient law governing the movement of an electric bus along a city route. To solve this problem, an algorithm is developed based on the dynamic programming method. The proposed method allows you to take into account the constraints imposed on the phase coordinates, control action, as well as on the time of the route. In the course of solving the problem, the model of rectilinear motion of an electric bus on a horizontal reference surface is considered, taking into account the assumptions that allow it to be adapted for the implementation of the method. For the formation of a control action in the equations of motion dynamics, an algorithm for changing the traction / braking torque on the wheels of an electric bus is considered, depending on the magnitude of the control parameter and the speed of motion. An optimal phase trajectory was obtained on a selected section of the road for the prototype of an electric bus. The article presents the comparison of simulation results obtained with the optimal energy efficient control law with the results obtained by a test driver. The comparison proved feasibility of the energy efficient control law for the automobile city electric transport.

  20. Appetite control and energy balance: impact of exercise.

    Science.gov (United States)

    Blundell, J E; Gibbons, C; Caudwell, P; Finlayson, G; Hopkins, M

    2015-02-01

    Exercise is widely regarded as one of the most valuable components of behaviour that can influence body weight and therefore help in the prevention and management of obesity. Indeed, long-term controlled trials show a clear dose-related effect of exercise on body weight. However, there is a suspicion, particularly fuelled by media reports, that exercise serves to increase hunger and drive up food intake thereby nullifying the energy expended through activity. Not everyone performing regular exercise will lose weight and several investigations have demonstrated a huge individual variability in the response to exercise regimes. What accounts for this heterogeneous response? First, exercise (or physical activity) through the expenditure of energy will influence the energy balance equation with the potential to generate an energy deficit. However, energy expenditure also influences the control of appetite (i.e. the physiological and psychological regulatory processes underpinning feeding) and energy intake. This dynamic interaction means that the prediction of a resultant shift in energy balance, and therefore weight change, will be complicated. In changing energy intake, exercise will impact on the biological mechanisms controlling appetite. It is becoming recognized that the major influences on the expression of appetite arise from fat-free mass and fat mass, resting metabolic rate, gastric adjustment to ingested food, changes in episodic peptides including insulin, ghrelin, cholecystokinin, glucagon-like peptide-1 and tyrosine-tyrosine, as well as tonic peptides such as leptin. Moreover, there is evidence that exercise will influence all of these components that, in turn, will influence the drive to eat through the modulation of hunger (a conscious sensation reflecting a mental urge to eat) and adjustments in postprandial satiety via an interaction with food composition. The specific actions of exercise on each physiological component will vary in strength from

  1. Remote control systems evolution in the new open energy market

    International Nuclear Information System (INIS)

    Castiglioni, L.

    2001-01-01

    Considering new energy market in Italy, the new role of remote control applications is discussed. In the open market the whole electric process is managed by several different actors; common protocol scheme and additional sharing data policies are necessaries facing the increased communications requirements due to deregulation. Remote control systems evolution then will lead from process oriented to data management oriented systems; related methodologies and solutions are described [it

  2. Nanostructured Solar Irradiation Control Materials for Solar Energy Conversion

    Science.gov (United States)

    Kang, Jinho; Marshall, I. A.; Torrico, M. N.; Taylor, C. R.; Ely, Jeffry; Henderson, Angel Z.; Kim, J.-W.; Sauti, G.; Gibbons, L. J.; Park, C.; hide

    2012-01-01

    Tailoring the solar absorptivity (alpha(sub s)) and thermal emissivity (epsilon(sub T)) of materials constitutes an innovative approach to solar energy control and energy conversion. Numerous ceramic and metallic materials are currently available for solar absorbance/thermal emittance control. However, conventional metal oxides and dielectric/metal/dielectric multi-coatings have limited utility due to residual shear stresses resulting from the different coefficient of thermal expansion of the layered materials. This research presents an alternate approach based on nanoparticle-filled polymers to afford mechanically durable solar-absorptive and thermally-emissive polymer nanocomposites. The alpha(sub s) and epsilon(sub T) were measured with various nano inclusions, such as carbon nanophase particles (CNPs), at different concentrations. Research has shown that adding only 5 wt% CNPs increased the alpha(sub s) and epsilon(sub T) by a factor of about 47 and 2, respectively, compared to the pristine polymer. The effect of solar irradiation control of the nanocomposite on solar energy conversion was studied. The solar irradiation control coatings increased the power generation of solar thermoelectric cells by more than 380% compared to that of a control power cell without solar irradiation control coatings.

  3. Energy Analysis for Air Conditioning System Using Fuzzy Logic Control

    Directory of Open Access Journals (Sweden)

    Henry Nasution

    2011-04-01

    Full Text Available Reducing energy consumption and to ensure thermal comfort are two important considerations for the designing an air conditioning system. An alternative approach to reduce energy consumption proposed in this study is to use a variable speed compressor. The control strategy will be proposed using the fuzzy logic controller (FLC. FLC was developed to imitate the performance of human expert operators by encoding their knowledge in the form of linguistic rules. The system is installed on a thermal environmental room with a data acquisition system to monitor the temperature of the room, coefficient of performance (COP, energy consumption and energy saving. The measurements taken during the two hour experimental periods at 5-minutes interval times for temperature setpoints of 20oC, 22oC and 24oC with internal heat loads 0, 500, 700 and 1000 W. The experimental results indicate that the proposed technique can save energy in comparison with On/Off and proportional-integral-derivative (PID control.

  4. Local sharing of cogeneration energy through individually prioritized controls for increased on-site energy utilization

    International Nuclear Information System (INIS)

    Hirvonen, Janne; Kayo, Genku; Hasan, Ala; Sirén, Kai

    2014-01-01

    Highlights: • Sharing of surplus heat and electricity produced by CHP plants in different types of buildings. • Individually prioritized control of CHP plants with direct local sharing and minimal storage capacity. • Energy sharing reduced primary energy consumption by 1–9% with biogas. • Excess energy minimized by thermal tracking. - Abstract: All over the world, including Japan, there are targets to decrease building energy consumption and increase renewable energy utilization. Combined heat and power (CHP) plants increase energy efficiency and are becoming popular in Japan. CHP plants produce both heat and power simultaneously, but there is not always a need for both. A cluster of several different buildings can increase total efficiency and reduce primary energy (PE) consumption by sharing excess heat and electricity between neighboring buildings. If the generated energy comes from renewable sources, energy sharing makes it easier to reach the net zero energy balance. By adjusting CHP sizes and operation patterns, the wasted heat and primary energy consumption can be minimized. Energy sharing has been explored in situations with identical buildings and centrally administered energy systems before, but not with different building types with separate systems. In this study, a cluster of Japanese office and residential buildings were combined to allow heat and electricity sharing based on cogeneration, using individually prioritized control (IPC) systems. TRNSYS simulation was used to match energy generation with pregenerated demand profiles. Absorption cooling was utilized to increase the benefits of local heat generation. Different CHP operation modes and plant sizes were tested. The benefit of surplus energy sharing depends on the CHP capacities and the fuel type. When using biogas, larger CHP plants provided lower total primary energy consumption, in the most extreme case lowering it by 71%, compared to the conventional case. Using natural gas

  5. Automatic Energy Control And Monitoring System For Building

    Directory of Open Access Journals (Sweden)

    Hnin Nu Thaung

    2015-08-01

    Full Text Available The use of smart home technology in the home or building offers significant potential for energy savings. In this paper an energy management system based on wireless sensor networks. The proposed system is composed of two main components a wireless sensor network and monitoring terminal. Wireless sensors are used for sensing and transmitting electricity data and remote monitoring and control of appliances are provided to users through computer. The system enables users to save energy by monitoring and controlling appliances through terminal. This paper gives an overview of sensor technology and wireless networks in the development of an intelligent energy management system for buildings. This technology has ample potential to change the way live and work. ZigBee is used as a communication medium in building intelligent energy management system in this paper. From the prototype setup it is shown that ZigBee is a suitable technology to be adopted as the communication infrastructure in energy management system for buildings .The proposed system can be installed and maintained in residential environments with ease.

  6. Radiological (MRI and Biochemical effects of Low Level LASER therapy in chronic Osteo arthritis in Al-Kharj, Saudi Arabia: A Randomized Control Trial

    Directory of Open Access Journals (Sweden)

    Gopal Nambi S

    2016-11-01

    Full Text Available Osteoarthritis is one of the degenerative diseases and Low level laser therapy (LLLT has been prescribed as nonoperative treatment in physiotherapy. But the available evidences of finding the radiological and biochemical effectiveness of LLLT are very few. So, the purpose of this study is to find the radiological and biochemical effect of Low level laser therapy (LLLT in the treatment of Osteoarthritis. 34 subjects who fulfilled the inclusion and exclusion criteria were divided into two groups (Active Laser group – ALG & Placebo Laser group - PLG with randomized sampling method. ALG was treated with active laser head, whereas PLG treated same like ALG but without emission of energy. Both groups were applied with kinesio tape for 4 weeks. The frequency of the treatment was three times per week for 4 weeks in both groups. Subjects were assessed at baseline, 4th and 8th week. Contact area (mm2 – medial & lateral and cartilage thickness (percentage - medial & lateral was measured by Magnetic resonance image (MRI and CTX-II (μmg/mmol was measured by urine analysis. A statistically significant (p ≤0.05 difference between both groups were noted at the period of 8 week for contact area (lateral and CTX-II and insignificant (p ≥ 0.05 difference in contact area (medial and cartilage thickness (medial & lateral were noted. In conclusion, the low level laser therapy is helpful in modifying the biochemical components and leads to make changes in the cartilage which subsequently improve the quality of life of OA patients.

  7. Emergency control center of the nuclear Regulatory Authority: a national, regional and international tool to coordinate the response to radiological and nuclear emergencies

    International Nuclear Information System (INIS)

    Jordan, Osvaldo; Hernandez, Daniel; Telleria, Diego; Bruno, Hector; Boutet, Luis; Kunst, Juan; Sadaniowski, Ivana; Rey, Hugo

    2008-01-01

    Full text: In the year 1998, with the regulation of the Nuclear Law, the Nuclear Regulatory Authority (ARN) is constituted as the national coordinator of the response in case of nuclear or radiological emergencies. The ARN builds his first operative center installed in his Head quarter in Buenos Aires. Likewise, from the obligations that come with the Convention of Early Notification of a Nuclear Accident and Convention on Assistance in the Case of a Nuclear Accident or Radiological Emergency, the ARN is the National Warning Point and the National Competent Authority. Therefore, the operative capacity of the center needs to be expanded to cover not only the national territory but also its link with the region and the IAEA, as an access point to the International community, as the conventions demand. For the purpose of giving ARN capacities which reflect the state of art at the international level on Nuclear Emergency Centers and warrant that its equipment and technology will be compatible with those abroad (mainly with IAEA), the ARN made an arrangements with Department of Energy of United States, in the framework of an existing bilateral Argentine Foreign Office/US Government agreement (Joint Standing Committee on Nuclear Cooperation). This agreement allows a deep experience exchange, high level specialists support and last generation equipment access. As a result, the center of ARN can be considerate as the most advanced civil nuclear emergency center in the region. This work describes the implementation process of the emergency center and the technical features, like the physical distribution, hardware and software resources, communication equipment, Geographic Information Systems, etc. (author)

  8. Optimization of Overtopping Wave Energy Converters by Geometry Control

    DEFF Research Database (Denmark)

    Victor, L.; Troch, P.; Kofoed, Jens Peter

    2011-01-01

    In this paper, the results of a study on the effects of geometry control on the performance of overtopping wave energy converters with a simple geometry built in coastal structures (simple OWECs) are presented. Empirical formulae, derived based on experimental tests on simple OWECs with varying...

  9. A history of the Atomic Energy Control Board

    International Nuclear Information System (INIS)

    Sims, G.H.E.

    1980-07-01

    Topics covered include the pre-history of the AECB, its creation, early operations and evolution, its relations with nuclear research, the uranium industry, and the nuclear power industry, its involvement with transportation and safeguards, and some current problems. The focus is on the Atomic Energy Control Act and regulations derived from the act

  10. Additive, control, energy, medical and other hot topics

    NARCIS (Netherlands)

    Brouwer, Dannis Michel

    2014-01-01

    The 14th International Conference of the European Society for Precision Engineering and Nanotechnology (euspen) was held in Dubrovnik, Croatia, on 2-6 June 2014. Among the hot topics discussed were additive manufacturing (AM), motion control in precision systems, renewable energy technologies, and

  11. Soil Sampling to Demonstrate Compliance with Department of Energy Radiological Clearance Requirements for the ALE Unit of the Hanford Reach National Monument

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G.; Dirkes, Roger L.; Napier, Bruce A.

    2007-04-01

    The Hanford Reach National Monument consists of several units, one of which is the Fitzner/Eberhardt Arid Lands Ecology Reserve (ALE) Unit. This unit is approximately 311 km2 of shrub-steppe habitat located to the south and west of Highway 240. To fulfill internal U. S. Department of Energy (DOE) requirements prior to any radiological clearance of land, DOE must evaluate the potential for residual radioactive contamination on this land and determine compliance with the requirements of DOE Order 5400.5. Historical soil monitoring conducted on ALE indicated soil concentrations of radionuclides were well below the Authorized Limits. However, the historical sampling was done at a limited number of sampling locations. Therefore, additional soil sampling was conducted to determine if the concentrations of radionuclides in soil on the ALE Unit were below the Authorized Limits. This report contains the results of 50 additional soil samples. The 50 soil samples collected from the ALE Unit all had concentrations of radionuclides far below the Authorized Limits. The average concentrations for all detectable radionuclides were less than the estimated Hanford Site background. Furthermore, the maximum observed soil concentrations for the radionuclides included in the Authorized Limits would result in a potential annual dose of 0.14 mrem assuming the most probable use scenario, a recreational visitor. This potential dose is well below the DOE 100-mrem per year dose limit for a member of the public. Spatial analysis of the results indicated no observable statistically significant differences between radionuclide concentrations across the ALE Unit. Furthermore, the results of the biota dose assessment screen, which used the ResRad Biota code, indicated that the concentrations of radionuclides in ALE Unit soil pose no significant health risk to biota.

  12. Routine Radiological Environmental Monitoring Plan

    International Nuclear Information System (INIS)

    Bechtel Nevada

    1998-01-01

    The U.S. Department of Energy manages the Nevada Test Site in a manner that meets evolving DOE Missions and responds to the concerns of affected and interested individuals and agencies. This Routine Radiological Monitoring Plan addressess complicance with DOE Orders 5400.1 and 5400.5 and other drivers requiring routine effluent monitoring and environmental surveillance on the Nevada Test Site. This monitoring plan, prepared in 1998, addresses the activities conducted onsite NTS under the Final Environmental Impact Statement and Record of Decision. This radiological monitoring plan, prepared on behalf of the Nevada Test Site Landlord, brings together sitewide environmental surveillance; site-specific effluent monitoring; and operational monitoring conducted by various missions, programs, and projects on the NTS. The plan provides an approach to identifying and conducting routine radiological monitoring at the NTS, based on integrated technical, scientific, and regulatory complicance data needs

  13. Radiological consequences of radioactive effluents

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1979-01-01

    A study of the differential radiological impact of the nuclear fuel cycle with and without plutonium recycle is being undertaken jointly by the National Radiological Protection Board and the Commissariat a l'Energie Atomique (CEA). A summary is given of the development of the methodology detailed in their first report to the Commission of the European Communities (CEC) (NRPB/CEA, A methodology for evaluating the radiological consequences of radioactive effluents released in normal operations. Luxembourg, CEC Doc. V/3011/75 EN (1979)). The Collective Effective Dose Equivalent Commitment was used in an attempt to assess the total health detriment. The application of the methodology within particular member states of the European Community has been discussed at seminars. Sensitivity analysis can identify the more important parameters for improving the accuracy of the assessment. (UK)

  14. Energy

    International Nuclear Information System (INIS)

    Meister, F.

    2001-01-01

    This chapter of the environmental control report deals with the environmental impact of energy production, energy conversion, atomic energy and renewable energy. The development of the energy consumption in Austria for the years 1993 to 1999 is given for the different energy types. The development of the use of renewable energy sources in Austria is given, different domestic heat-systems are compared, life cycles and environmental balance are outlined. (a.n.)

  15. Educational treasures in Radiology: The Radiology Olympics - striving for gold in Radiology education

    OpenAIRE

    Talanow, Roland

    2010-01-01

    This article focuses on Radiology Olympics (www.RadiologyOlympics.com) - a collaboration with the international Radiology community for Radiology education, Radiolopolis (www.Radiolopolis.com). The Radiology Olympics honour the movers and shakers in Radiology education and offer an easy to use platform for educating medical professionals based on Radiology cases.

  16. Radiological design criteria

    International Nuclear Information System (INIS)

    Selby, J.M.; Andersen, B.V.; Carter, L.A.; Waite, D.A.

    1977-01-01

    Many new nuclear facilities are unsatisfactory from a radiation protection point of view, particularly when striving to maintain occupational exposure as low as practicable 'ALAP'. Radiation protection is achieved through physical protective features supplemented by administrative controls. Adequate physical protective feature should be achieved during construction so that supplemental administrative controls may be kept simple and workable. Many nuclear facilities fall short of adequate physical protective features, thus, remedial and sometimes awkward administrative procedures are required to safely conduct work. In reviewing the various handbooks, reports and regulations which deal with radiation protection, it may be noted that there is minimal radiological design guidance for application to nuclear facilities. A set of criteria or codes covering functional areas rather than specific nuclear facility types is badly needed. The following are suggested as functional areas to be considered: characterization of the Facility; siting and access; design exposure limits; layout (people and materials flow); ventilation and effluent control; radiation protection facilities and systems. The application of such radiological design criteria early in the design process would provide some assurance that nuclear facilities will be safe, flexible, and efficient with a minimum of costly retrofitting or administrative restrictions. Criteria which we have found helpful in these functional areas is discussed together with justification for adoption of such criteria and identification of problems which still require solution

  17. Energy Auditor and Quality Control Inspector Competency Model

    Energy Technology Data Exchange (ETDEWEB)

    Head, Heather R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schroeder, Derek [U.S. Department of Energy; Cutchin, Kelly [Simonson Management Services

    2018-05-02

    The Energy Auditor (EA) and Quality Control Inspector (QCI) Competency model was developed to identify the soft skills, foundational competencies and define the levels of Knowledge, Skills, and Abilities (KSAs) required to successfully perform the tasks defined in the EA and QCI Job Task Analysis (JTAs), the U.S. Department of Energy (DOE) used the U.S. Department of Labor's (DOL) Competency Model Clearinghouse resources to develop a QCI and EA Competency Model. To keep the QCI and EA competency model consistent with other construction and energy management competency models, DOE and the National Renewable Energy Laboratory used the existing 'Residential Construction Competency Model' and the 'Advanced Commercial Building Competency Model' where appropriate.

  18. Radiology and the law in South Africa

    International Nuclear Information System (INIS)

    Muller, C.J.B.

    1978-01-01

    In terms of regulations gazetted in 1973, the Department of Health has control of the practice of medical radiology in South Africa. The regulations and the rules of the South African Medical and Dental Council that apply to radiology are discussed, and the legal position of workers is noted

  19. Active Noise Control Experiments using Sound Energy Flu

    Science.gov (United States)

    Krause, Uli

    2015-03-01

    This paper reports on the latest results concerning the active noise control approach using net flow of acoustic energy. The test set-up consists of two loudspeakers simulating the engine noise and two smaller loudspeakers which belong to the active noise system. The system is completed by two acceleration sensors and one microphone per loudspeaker. The microphones are located in the near sound field of the loudspeakers. The control algorithm including the update equation of the feed-forward controller is introduced. Numerical simulations are performed with a comparison to a state of the art method minimising the radiated sound power. The proposed approach is experimentally validated.

  20. Controlling chaotic and hyperchaotic systems via energy regulation

    International Nuclear Information System (INIS)

    Laval, L.; M'Sirdi, N.K.

    2003-01-01

    This paper focuses on a new control approach to steer trajectories of chaotic or hyperchaotic systems towards stable periodic orbits or stationary points of interest. This approach mainly consists in a variable structure control (VSC) that we extend by explicitly considering the system energy as basis for both controller design and system stabilization. In this paper, we present some theoretical results for a class of nonlinear (possibly chaotic or hyperchaotic) systems. Then some capabilities of the proposed approach are illustrated through examples related to a four-dimensional hyperchaotic system