WorldWideScience

Sample records for energy performance standards

  1. 10 CFR 435.4 - Energy efficiency performance standard.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy efficiency performance standard. 435.4 Section 435.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...

  2. 10 CFR 433.4 - Energy efficiency performance standard.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy efficiency performance standard. 433.4 Section 433.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR THE DESIGN AND... consumption level at or better than the maximum level of energy efficiency that is life-cycle cost-effective...

  3. Calculation of the yearly energy performance of heating systems based on the European Building Energy Directive and related CEN Standards

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; de Carli, Michele

    2011-01-01

    According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting syst......–20% of the building energy demand. The additional loss depends on the type of heat emitter, type of control, pump and boiler. Keywords: Heating systems; CEN standards; Energy performance; Calculation methods......According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting...... systems. This energy declaration must refer to the primary energy or CO2 emissions. The European Organization for Standardization (CEN) has prepared a series of standards for energy performance calculations for buildings and systems. This paper presents related standards for heating systems. The relevant...

  4. Energy Efficiency: The Implementation of Minimum Energy Performance Standard (MEPS Application on Home Appliances for Residential

    Directory of Open Access Journals (Sweden)

    Rahman K.A

    2016-01-01

    Full Text Available Generally, Minimum Energy Performance Standard (MEPS has been widespread across the country especially developed country. However, most consumers do not even know about the MEPS. Without sufficient knowledge, much energy have been wasted before this. The aim of this study is to review the implementation of MEPS of Asia country and to compare electricity consumption of home appliances with star rating and without star rating. In order to fulfil the objectives of the study, the equipment must be chosen correctly and must be learned properly. The home appliances that will be used also need to be chosen so that the comparison between the appliances will be matched correctly. To understand the results, the analysis was done using graphs and table. The purpose of using graph and table is to understand the comparison between appliances more clearly. The results show that home appliances with MEPS is more efficient on energy saving rather than without MEPS. This is the evidence as a method to educate a consumer on energy saving.

  5. New Buildings Energy Performance Improvement through Incorporation of New Proven Technologies into Standard Designs. Standard Design for TEMF

    National Research Council Canada - National Science Library

    Zhivov, Alexander M

    2004-01-01

    ISSUES: Current Army Standard Designs don't specify potential energy saving and sustainable design opportunities, available energy saving technologies, and technologies resulting in better indoor air quality...

  6. Utility and performance relative to consumer product energy efficiency standards. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Coggins, J.L.

    1979-12-14

    An investigation of the relative utility and performance of nine major household consumer products covered by the Energy Policy and Conservation Act is summarized. The objective was to define the terms utility and performance, to recommend methods for quantifying these two concepts, and to recommend an approach for dealing with utility and performance issues in the energy efficiency standards program. The definitions developed are: performance of a consumer product is the objective measure of how well, with the expected level of consumer input (following the manufacturer's instructions for installation and operation), the product does its intended job; and utility of a consumer product is a subjective measure, based on the consumer's perception, of the capability of the product to satisfy human needs. Quantification is based on test procedures and consumer survey methods which are largely already in use by industry. Utility and performance issues are important in product classification for prescribing energy efficiency standards. The recommended approach to utility and performance issues and classification is: prior to setting standards, evaluate utility and performance issues in the most quantitative way allowed by resources and schedules in order to develop classification guidelines. This approach requires no changes in existing Department of Energy test procedures.

  7. Standardization of the energy performance of photovoltaic modules in real operating conditions

    Directory of Open Access Journals (Sweden)

    Viganó Davide

    2014-01-01

    Full Text Available The performance of a PV module at STC [1] is a useful indicator for comparing the peak performance of different module types, but on its own is not sufficient to accurately predict how much energy a module will deliver in the field when subjected to a wide range of real operating conditions [2]. An Energy Rating approach has to be preferred for that aim. It is currently under development the standard series IEC 61853 on Energy Rating, for which only part 1 [3] has been issued. It describes methods to characterize the module performance as a function of irradiance and temperature. The reproducibility of the power matrix measurements obtained by the three different methods specified in the standard, namely: under natural sunlight using a tracking system; under natural sunlight without tracker; and a large area pulsed solar simulator of Class AAA were evaluated and discussed [4,5]. The work here presented is focused on the second method listed above, which explores the real working conditions for a PV device and therefore it represents the situation where Energy Rating procedures are expected to give the largest deviations from the STC predictions. The system for continuous monitoring of module performances, already implemented at ESTI, has been recently replaced with a new system having a number of improvements described in the following. The two system results have been compared showing a discrete compatibility. The two power matrices are then merged together using a weighted average and compared to those acquired with the other two remaining “ideal” systems. An interesting tendency seems to come up from this comparison, making the power rating under real operating conditions an essential procedure for energy rating purposes.

  8. Department of Energy standard for the performance testing of personnel dosimetry systems

    International Nuclear Information System (INIS)

    1986-12-01

    This standard is intended to be used in the Department of Energy Laboratory Accreditation Program (DOELAP) for personnel dosimetry systems. It is based on the American National Standards Institute's (ANSI) ''Criteria for Testing Personnel Dosimetry Performance,'' ANSI N13.11-1983, recommendations made to DOE in ''Guidelines for the Calibration of Personnel Dosimeters,'' Pacific Northwest Laboratory (PNL)-4515 and comments received during peer review by DOE and DOE contractor personnel. The recommendations contained in PNL-4515 were based on an evaluation of ANSI N13.11 conducted for the Office of Nuclear Safety, DOE, by PNL. Parts of ANSI N13.11 that did not require modification were used essentially intact in this standard to maintain consistency with nationally recognized standards. Modifications to this standard have resulted from several DOE/DOE contractor reviews and a pilot testing session. An initial peer review by selected DOE and DOE contractor representatives on technical content was conducted in 1983. A review by DOE field offices, program offices, and contractors was conducted in mid-1984. A pilot performance testing session sponsored by the Office of Nuclear Safety was conducted in early 1985 by the Radiological and Environmental Sciences Laboratory, Idaho Falls. Results of the pilot test were reviewed in late 1985 by a DOE and DOE contractor committee. 11 refs., 4 tabs

  9. Performance test for implantation of a primary standard of low energy X-ray beams

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Peixoto, Jose Guilherme P.

    2005-01-01

    The implementation of a standard laboratory of calibration chambers that will serve to radiotherapy activities, radiodiagnosis and radioprotection, depends on the knowledge of physical and dosimetric parameters that characterize the quality of the radiation beam. With the aim of verifying the reliability of the ionizing free-air chamber with variable volume manufactured by Victoreen Instruments, model 481, as a primary standard, a study of the performance of the chamber to x-rays qualities of low energy was developed in this work. These qualities are the ones recommended by 'Bureau International des Poids et Mesures' - BIPM, for daily routine of the calibration service performed by the 'Laboratorio Nacional de Metrologia das Radiacoes Ionizantes - LNMRI/IRD, for calibration of this secondary standard chambers that serve to the control in hospitals, clinics and industries. The results obtained at the present work show that the Victoreen chamber model 481 behaves as a primary standard, being easy to handle and having simple mechanical construction, and showing an expanded uncertainty equal to 0,26%, regarding the quality of the radiation beam of 30 kV. However, some of the equipment used at the present study need to be submitted to a strict routine calibration, in order for the laboratory to be in accordance with the recommendations of the standard ABNT -NBR ISO/IEC 17025 (2003). (author)

  10. The IEEE 1355 Standard. Developments, performance and application in high energy physics

    International Nuclear Information System (INIS)

    Haas, S.

    1998-12-01

    The data acquisition systems of the next generation High Energy Physics experiments at the Large Hadron Collider (LHC) at CERN will rely on high-speed point-to-point links and switching networks for their higher level trigger and event building systems. This thesis provides a detailed evaluation of the DS-Link and switch technology, which is based on the IEEE 1355 standard for Heterogeneous Interconnect (HIC). The DS-Link is a bidirectional point-to-point serial interconnect, operating at speeds up to 200 MBaud. The objective of this thesis was to study the performance of the IEEE 1355 link and switch technology and to demonstrate that switching networks using this technology would scale to meet the requirements of the High Energy Physics applications

  11. The Impact of Minimum Energy Performance Standards (MEPS) Regulation on Electricity Saving in Malaysia

    Science.gov (United States)

    Fatihah Salleh, Siti; Eqwan Roslan, Mohd; Isa, Aishah Mohd; Faizal Basri Nair, Mohd; Syafiqah Salleh, Siti

    2018-03-01

    One of Malaysia’s key strategies to promote efficient energy use in the country is to implement the minimum energy performance standards (MEPS) through the Electricity Regulations (Amendment) 2013. Five selected electrical appliances (refrigerator, air conditioner, television, domestic fans and lamp fittings) must comply with MEPS requirement in order to be sold in Malaysian market. Manufacturers, importers or distributors are issued Certificate of Approval (COA) if products are MEPS-compliant. In 2015, 1,215 COAs were issued but the number of MEPS products in the market is unknown. This work collects sales data from major manufacturers to estimate the annual sales of MEPS appliances and the cumulative electricity consumption and electricity saving. It was found that most products sold have 3-star rating and above. By year 2015, total cumulative electricity savings gained from MEPS implementation is 3,645 GWh, with air conditioner being the highest contributor (30%). In the future, it is recommended that more MEPS products and related incentives be introduced to further improve efficiency of energy use in Malaysia.

  12. Standardized performance tests of collectors of solar thermal energy: Prototype moderately concentrating grooved collectors

    Science.gov (United States)

    1976-01-01

    Prototypes of moderately concentrating grooved collectors were tested with a solar simulator for varying inlet temperature, flux level, and incident angle. Collector performance is correlated in terms of inlet temperature and flux level.

  13. Standards for Lithotripter Performance

    Science.gov (United States)

    Schultheiss, Reiner; Doerffel, Michael

    2008-09-01

    Standards for lithotripsy have been developed by the International Electrotechnical Commission (IEC) and the FDA. In addition to the existing regulations and norms for the manufacturers, special standards were developed to address a treatment method developed in the early 1980's using extracorporeal shock waves. Initially, the FDA regulated the premarket approval process for lithotripters as a Class III device but reclassified lithotripters in 2000 to a Class II device. The corresponding guidance document for showing the substantial equivalence of new devices with predicate devices will be described in detail. The FDA guidance document is very useful in helping device manufacturers: (i) develop technical performance testing for a shock wave lithotripter within the parameters of an FDA submission, and (ii) conduct clinical performance testing via at least one clinical confirmation study with a small number of subjects. Unfortunately although the submitted data are available at the FDA they are not available in the marketplace and this causes difficulties for physicians in deciding which device to use. The results of the technical performance testing of the LithoGold™ are provided.

  14. PROCAL: A Set of 40 Peptide Standards for Retention Time Indexing, Column Performance Monitoring, and Collision Energy Calibration.

    Science.gov (United States)

    Zolg, Daniel Paul; Wilhelm, Mathias; Yu, Peng; Knaute, Tobias; Zerweck, Johannes; Wenschuh, Holger; Reimer, Ulf; Schnatbaum, Karsten; Kuster, Bernhard

    2017-11-01

    Beyond specific applications, such as the relative or absolute quantification of peptides in targeted proteomic experiments, synthetic spike-in peptides are not yet systematically used as internal standards in bottom-up proteomics. A number of retention time standards have been reported that enable chromatographic aligning of multiple LC-MS/MS experiments. However, only few peptides are typically included in such sets limiting the analytical parameters that can be monitored. Here, we describe PROCAL (ProteomeTools Calibration Standard), a set of 40 synthetic peptides that span the entire hydrophobicity range of tryptic digests, enabling not only accurate determination of retention time indices but also monitoring of chromatographic separation performance over time. The fragmentation characteristics of the peptides can also be used to calibrate and compare collision energies between mass spectrometers. The sequences of all selected peptides do not occur in any natural protein, thus eliminating the need for stable isotope labeling. We anticipate that this set of peptides will be useful for multiple purposes in individual laboratories but also aiding the transfer of data acquisition and analysis methods between laboratories, notably the use of spectral libraries. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Energy informatics: Fundamentals and standardization

    Directory of Open Access Journals (Sweden)

    Biyao Huang

    2017-06-01

    Full Text Available Based on international standardization and power utility practices, this paper presents a preliminary and systematic study on the field of energy informatics and analyzes boundary expansion of information and energy system, and the convergence of energy system and ICT. A comprehensive introduction of the fundamentals and standardization of energy informatics is provided, and several key open issues are identified.

  16. Energy Building Regulations: The Effect of the Federal Performance Standards on Building Code Administration and the Conservation of Energy in New Buildings.

    Science.gov (United States)

    Kopper, William D.

    1980-01-01

    Explores the changes in the administration and enforcement of building regulations that will be engendered by the proposed federal energy building standards. Also evaluates the effectiveness of those standards in meeting congressional intent. Available from U.C. Davis Law Review, School of Law, Martin Luther King Jr. Hall, University of…

  17. Calculation of the yearly energy performance of heating systems based on the European Building Directive and related CEN Standards

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Langkilde, Gunnar

    2009-01-01

    In 2003 the European Commission (EC) issued a directive, 2002/91/EC [1]. The objective of this directive is to promote the improvement of the energy performance of buildings within the community, taking into account outdoor climatic and local conditions, as well as indoor climate requirements and...

  18. Construction cost impact analysis of the U.S. Department of Energy mandatory performance standards for new federal commercial and multi-family, high-rise residential buildings

    International Nuclear Information System (INIS)

    Di Massa, F.V.; Hadley, D.L.; Halverson, M.A.

    1993-12-01

    In accordance with federal legislation, the U.S. Department of Energy (DOE) has conducted a project to demonstrate use of its Energy Conservation Voluntary Performance Standards for Commercial and Multi-Family High-Rise Residential Buildings; Mandatory for New Federal Buildings; Interim Rule (referred to in this report as DOE-1993). A key requisite of the legislation requires DOE to develop commercial building energy standards that are cost effective. During the demonstration project, DOE specifically addressed this issue by assessing the impacts of the standards on (1) construction costs, (2) builders (and especially small builders) of multi-family, high-rise buildings, and (3) the ability of low-to moderate-income persons to purchase or rent units in such buildings. This document reports on this project

  19. Department of Energy Nuclear Energy Standards Program

    International Nuclear Information System (INIS)

    Silver, E.G.

    1980-01-01

    The policy with respect to the development and use of standards in the Department of Energy (DOE) programs concerned with maintaining and developing the nuclear option for the civilian sector (both in the form of the currently used light water reactors and for advanced concepts including the Liquid Metal Fast Breeder Reactor), is embodied in a Nuclear Standards Policy, issued in 1978, whose perspectives and philosophy are discussed

  20. Argentine nuclear energy standardization activities

    International Nuclear Information System (INIS)

    Boero, Norma; Corcuera, Roberto; Palacios, Tulio A.; Hey, Alfredo M.; Berte, G.; Trama, L.

    2004-01-01

    The International Organization for Standardization (ISO) has more than 200 Technical Committees that develop technical standards. During April 2004 took place in Buenos Aires the 14th Plenary of the ISO/TC 85 Nuclear Energy Committee. During this Plenary issues as Nuclear Terminology, Radiation Protection, Nuclear Fuels, Nuclear Reactors and Irradiation Dosimetry was dealt with. 105 International delegates and 45 National delegates (belonging to CNEA, ARN, NASA, INVAP, CONUAR, IONICS and other organizations) attended the meetings. During this meeting ISO/TC 85 changed its scope; the new scope of the Committee is 'Standardization in the fields of peaceful applications of nuclear energy and of the protection of individuals against all sources of ionizing radiations'. This work summarizes the most important advances and resolutions about the development of standards taken during this meeting as well as the main conclusions. (author) [es

  1. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  2. Estimate of Cost-Effective Potential for Minimum Efficiency Performance Standards in 13 Major World Economies Energy Savings, Environmental and Financial Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bojda, Nicholas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ke, Jing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McNeil, Michael A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-07-01

    This study analyzes the financial impacts on consumers of minimum efficiency performance standards (MEPS) for appliances that could be implemented in 13 major economies around the world. We use the Bottom-Up Energy Analysis System (BUENAS), developed at Lawrence Berkeley National Laboratory (LBNL), to analyze various appliance efficiency target levels to estimate the net present value (NPV) of policies designed to provide maximum energy savings while not penalizing consumers financially. These policies constitute what we call the “cost-effective potential” (CEP) scenario. The CEP scenario is designed to answer the question: How high can we raise the efficiency bar in mandatory programs while still saving consumers money?

  3. Canadian energy standards : residential energy code requirements

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, K. [SAR Engineering Ltd., Burnaby, BC (Canada)

    2006-09-15

    A survey of residential energy code requirements was discussed. New housing is approximately 13 per cent more efficient than housing built 15 years ago, and more stringent energy efficiency requirements in building codes have contributed to decreased energy use and greenhouse gas (GHG) emissions. However, a survey of residential energy codes across Canada has determined that explicit demands for energy efficiency are currently only present in British Columbia (BC), Manitoba, Ontario and Quebec. The survey evaluated more than 4300 single-detached homes built between 2000 and 2005 using data from the EnerGuide for Houses (EGH) database. House area, volume, airtightness and construction characteristics were reviewed to create archetypes for 8 geographic areas. The survey indicated that in Quebec and the Maritimes, 90 per cent of houses comply with ventilation system requirements of the National Building Code, while compliance in the rest of Canada is much lower. Heat recovery ventilation use is predominant in the Atlantic provinces. Direct-vent or condensing furnaces constitute the majority of installed systems in provinces where natural gas is the primary space heating fuel. Details of Insulation levels for walls, double-glazed windows, and building code insulation standards were also reviewed. It was concluded that if R-2000 levels of energy efficiency were applied, total average energy consumption would be reduced by 36 per cent in Canada. 2 tabs.

  4. Energy efficiency standards and innovation

    Science.gov (United States)

    Morrison, Geoff

    2015-01-01

    Van Buskirk et al (2014 Environ. Res. Lett. 9 114010) demonstrate that the purchase price, lifecycle cost and price of improving efficiency (i.e. the incremental price of efficiency gain) decline at an accelerated rate following the adoption of the first energy efficiency standards for five consumer products. The authors show these trends using an experience curve framework (i.e. price/cost versus cumulative production). While the paper does not draw a causal link between standards and declining prices, they provide suggestive evidence using markets in the US and Europe. Below, I discuss the potential implications of the work.

  5. Energy retrofit of an office building by substitution of the generation system: performance evaluation via dynamic simulation versus current technical standards

    International Nuclear Information System (INIS)

    Testi, D; Schito, E; Grassi, W; Menchetti, E

    2014-01-01

    Constructions built in Italy before 1945 (about 30% of the total built stock) feature low energy efficiency. Retrofit actions in this field can lead to valuable energetic and economic savings. In this work, we ran a dynamic simulation of a historical building of the University of Pisa during the heating season. We firstly evaluated the energy requirements of the building and the performance of the existing natural gas boiler, validated with past billings of natural gas. We also verified the energetic savings obtainable by the substitution of the boiler with an air-to-water electrically-driven modulating heat pump, simulated through a cycle-based model, evaluating the main economic metrics. The cycle-based model of the heat pump, validated with manufacturers' data available only at specified temperature and load conditions, can provide more accurate results than the simplified models adopted by current technical standards, thus increasing the effectiveness of energy audits

  6. Standardized performance tests of collectors of solar thermal energy - A flat-plate copper collector with parallel mylar striping

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are reported for a flat plate solar collector whose performance was determined in a solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  7. Standardized performance tests of collectors of solar thermal energy: A selectively coated, steel collector with one transparent cover

    Science.gov (United States)

    1976-01-01

    Basic test results are presented of a flat-plate solar collector whose performance was determined in solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency was correlated in terms of inlet temperature and flux level.

  8. Standardized performance tests of collectors of solar thermal energy: An evacuated flatplate copper collector with a serpentine flow distribution

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are given for a flat plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  9. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    This Department of Energy (DOE) technical standards list (TSL) has been prepared by the Office of Nuclear Safety Policy and Standards (EH-31) on the basis of currently available technical information. Periodic updates of this TSL will be issued as additional information is received on standardization documents being issued, adopted, or canceled by DOE. This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listings of current DOE technical standards, non-Government standards that have been adopted by DOE, other standards-related documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  10. Effects of heat loss as percentage of fuel's energy, friction and variable specific heats of working fluid on performance of air standard Otto cycle

    International Nuclear Information System (INIS)

    Lin, J.-C.; Hou, S.-S.

    2008-01-01

    The objective of this study is to analyze the effects of heat loss characterized by a percentage of the fuel's energy, friction and variable specific heats of working fluid on the performance of an air standard Otto cycle with a restriction of maximum cycle temperature. A more realistic and precise relationship between the fuel's chemical energy and the heat leakage that is based on a pair of inequalities is derived through the resulting temperature. The variations in power output and thermal efficiency with compression ratio, and the relations between the power output and the thermal efficiency of the cycle are presented. The results show that the power output as well as the efficiency where maximum power output occurs will increase with increase of the maximum cycle temperature. The temperature dependent specific heats of the working fluid have a significant influence on the performance. The power output and the working range of the cycle increase with the increase of specific heats of the working fluid, while the efficiency decreases with the increase of specific heats of the working fluid. The friction loss has a negative effect on the performance. Therefore, the power output and efficiency of the cycle decrease with increasing friction loss. It is noteworthy that the effects of heat loss characterized by a percentage of the fuel's energy, friction and variable specific heats of the working fluid on the performance of an Otto cycle engine are significant and should be considered in practical cycle analysis. The results obtained in the present study are of importance to provide good guidance for performance evaluation and improvement of practical Otto engines

  11. Department of Energy Standards Index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This TSL, intended for use in selecting and using DOE technical standards and other Government and non-Government standards, provides listing of current and inactive DOE technical standards, non-Government standards adopted by DOE, other Government documents in which DOE has a recorded interest, and cancelled DOE technical standards.

  12. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  13. Energy Performance of Buildings

    DEFF Research Database (Denmark)

    Heiselberg, Per

    2007-01-01

    "Sustainable development" has been defined best by the Brundtland Commission as "development that meets the needs of the present without compromising the ability of future generations to meet their own needs". Adequate and affordable energy supplies have been key to economic development and are c......"Sustainable development" has been defined best by the Brundtland Commission as "development that meets the needs of the present without compromising the ability of future generations to meet their own needs". Adequate and affordable energy supplies have been key to economic development...... and are central to improving social and economic well- being, and human welfare and raising living standards. Even if energy is essential for development, it is only a means to an end. The end is good health, high living standards, a sustainable economy and a clean environment. The European Climate change...... programme (ECCP) was established in June 2000 to help identify the most environmentally cost-effective measures enabling the EU to meet its target under the Kyoto Protocol, namely an 8% reduction in greenhouse gas emissions from 1990 levels by 2012. Energy use in buildings accounts for almost half of all CO...

  14. Energy performance assessment methodology

    Energy Technology Data Exchange (ETDEWEB)

    Platzer, W.J. [Fraunhofer Inst. for Solar Energy Systems, Freiburg (Germany)

    2006-01-15

    The energy performance of buildings are intimately connected to the energy performance of building envelopes. The better we understand the relation between the quality of the envelope and the energy consumption of the building, the better we can improve both. We have to consider not only heating but all service energies related to the human comfort in the building, such as cooling, ventilation, lighting as well. The complexity coming from this embracing approach is not to be underestimated. It is less and less possible to realted simple characteristic performance indicators of building envelopes (such as the U-value) to the overall energy performance. On the one hand much more paramters (e.g. light transmittance) come into the picture we have to assess the product quality in a multidimensional world. Secondly buildings more and more have to work on a narrow optimum: For an old, badly insulated building all solar gains are useful for a high-performance building with very good insulation and heat recovery systems in the ventilation overheating becomes more likely. Thus we have to control the solar gains, and sometimes we need high gains, sometimes low ones. And thirdly we see that the technology within the building and the user patterns and interactions as well influence the performance of a building envelope. The aim of this project within IEA Task27 was to improve our knowledge on the complex situation and also to give a principal approach how to assess the performance of the building envelope. The participants have contributed to this aim not pretending that we have reached the end. (au)

  15. Effects of the standardized ileal digestible lysine to metabolizable energy ratio on performance and carcass characteristics of growing-finishing pigs

    Directory of Open Access Journals (Sweden)

    Li Pengfei

    2012-03-01

    Full Text Available Abstract A total of 2,121 growing-finishing pigs (Duroc × Landrace × Large White were utilized in six experiments conducted to determine the effects of different ratios of standardized ileal digestible lysine (SID-Lys to metabolizable energy (ME on the performance and carcass characteristics of growing-finishing pigs. Exps. 1 (30 to 50 kg, 2 (52 to 70 kg and 3 (81 to 104 kg were conducted to find an optimum ME level and then this level was used in Exps. 4 (29 to 47 kg, 5 (54 to 76 kg and 6 (84 to 109 kg to test the response of pigs to different ratios of SID-Lys:ME. In Exps.1 to 3, four treatments were used consisting of diets with a formulated ME content of 3.1, 3.2, 3.3 or 3.4 in Exps. 1 and 2 while Exp. 3 used 3.05, 3.15, 3.25 or 3.35 Mcal/kg. A constant SID-Lys:ME ratio of 2.6, 2.3 or 2.0 g/Mcal was used in Exps. 1, 2 and 3, respectively. Weight gain was significantly increased with increasing energy level in Exp.1 while weight gain was unaltered in Exps. 2 and 3. For all three experiments, feed intake was decreased (P P P P P P

  16. Distributed Energy Resource (DER) Cybersecurity Standards

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, Danish [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Johnson, Jay [Sandia National Laboratories

    2017-11-08

    This presentation covers the work that Sandia National Laboratories and National Renewable Energy Laboratory are doing for distributed energy resource cybersecurity standards, prepared for NREL's Annual Cybersecurity & Resilience Workshop on October 9-10, 2017.

  17. Building Standards and Codes for Energy Conservation

    Science.gov (United States)

    Gross, James G.; Pierlert, James H.

    1977-01-01

    Current activity intended to lead to energy conservation measures in building codes and standards is reviewed by members of the Office of Building Standards and Codes Services of the National Bureau of Standards. For journal availability see HE 508 931. (LBH)

  18. Background to the development process, Automated Residential Energy Standard (ARES) in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-09-01

    This report documents the development and testing of a set of recommendations generated to serve as a primary basis for the Congressionally-mandated residential standard. This report treats only the residential building recommendations.

  19. 77 FR 56421 - Standards of Performance for Petroleum Refineries; Standards of Performance for Petroleum...

    Science.gov (United States)

    2012-09-12

    ... Parts 9 and 60 Standards of Performance for Petroleum Refineries; Standards of Performance for Petroleum...-9672-3] RIN 2060-AN72 Standards of Performance for Petroleum Refineries; Standards of Performance for Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007...

  20. Nuclear performance standards: Promoting efficient generation

    International Nuclear Information System (INIS)

    Nagelhout, M.

    1990-01-01

    Nuclear plant performance standards are designed to share the risks of operation associated with nuclear generation. Such standards often shift risks from ratepayers to utility shareholders, even without a finding of imprudence or mismanagement. The rationale underlying nuclear performance standards is that ratepayers should not be responsible for excessive replacement power costs incurred as a result of unreasonable decisions by utility management, especially because the high fixed costs of nuclear plants are already included in base rates. In addition, performance standards can be designed to provide incentives to reward utilities that achieve superior nuclear performance, for the benefit of both ratepayers and shareholders

  1. Performance Standards for Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  2. Compilation and evaluation of high energy γ-ray standards from nuclear reactions. Work performed under the coordinated research project 'Update of X- and γ-ray decay data standards for detector calibration'

    International Nuclear Information System (INIS)

    Marcinkowski, A.; Marianski, B.

    1999-02-01

    The report presents the following aspects needed for the compilation and evaluation of high energy γ-ray standards from nuclear reactions: evaluation of emission probabilities of γ-rays with energies 4.44 MeV and 15.11 MeV from 12 C * , preparation of the list of reactions suitable for production of the above mentioned excited radionuclide, and compilation and evaluation of cross sections for these reactions, including inelastic proton scattering on 12 C and radiative capture on 11 B

  3. Energy efficiency standards for residential and commercial equipment: Additional opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Rosenquist, Greg; McNeil, Michael; Iyer, Maithili; Meyers, Steve; McMahon, Jim

    2004-08-02

    Energy efficiency standards set minimum levels of energy efficiency that must be met by new products. Depending on the dynamics of the market and the level of the standard, the effect on the market for a given product may be small, moderate, or large. Energy efficiency standards address a number of market failures that exist in the buildings sector. Decisions about efficiency levels often are made by people who will not be responsible for the energy bill, such as landlords or developers of commercial buildings. Many buildings are occupied for their entire lives by very temporary owners or renters, each unwilling to make long-term investments that would mostly reward subsequent users. And sometimes what looks like apathy about efficiency merely reflects inadequate information or time invested to evaluate it. In addition to these sector-specific market failures, energy efficiency standards address the endemic failure of energy prices to incorporate externalities. In the U.S., energy efficiency standards for consumer products were first implemented in California in 1977. National standards became effective starting in 1988. By the end of 2001, national standards were in effect for over a dozen residential appliances, as well as for a number of commercial sector products. Updated standards will take effect in the next few years for several products. Outside the U.S., over 30 countries have adopted minimum energy performance standards. Technologies and markets are dynamic, and additional opportunities to improve energy efficiency exist. There are two main avenues for extending energy efficiency standards. One is upgrading standards that already exist for specific products. The other is adopting standards for products that are not covered by existing standards. In the absence of new and upgraded energy efficiency standards, it is likely that many new products will enter the stock with lower levels of energy efficiency than would otherwise be the case. Once in the stock

  4. Performance standards of road safety management

    Directory of Open Access Journals (Sweden)

    Čabarkapa Milenko R.

    2016-01-01

    Full Text Available Road safety management controlling means the process of finding out the information whether the road safety is improving in a measure to achieve the objectives. The process of control consists of three basic elements: definition of performances and standards, measurement of current performances and comparison with the set standards, and improvement of current performances, if they deviate from the set standards. The performance standards of road safety management system are focused on a performances measurement, in terms of their design and characteristics, in order to support the performances improvement of road safety system and thus, ultimately, improve the road safety. Defining the performance standards of road safety management system, except that determines the design of the system for performances measurement, directly sets requirements whose fulfillment will produce a road safety improvement. The road safety management system, based on the performance standards of road safety, with a focus on results, will produce the continuous improvement of road safety, achieving the long-term 'vision zero', the philosophy of road safety, that human life and health take priority over mobility and other traffic objectives of the road traffic.

  5. Business School's Performance Management System Standards Design

    Science.gov (United States)

    Azis, Anton Mulyono; Simatupang, Togar M.; Wibisono, Dermawan; Basri, Mursyid Hasan

    2014-01-01

    This paper aims to compare various Performance Management Systems (PMS) for business school in order to find the strengths of each standard as inputs to design new model of PMS. There are many critical aspects and gaps notified for new model to improve performance and even recognized that self evaluation performance management is not well…

  6. DOE [Department of Energy]-Nuclear Energy Standards Program annual assessment, FY 1990

    International Nuclear Information System (INIS)

    Williams, D.L. Jr.

    1990-11-01

    To meet the objectives of the programs funded by the Department of Energy (DOE)-Nuclear Energy (NE) Technology Support Programs, the Performance Assurance Project Office (PAPO) administers a nuclear standards program and related activities and fosters the development and application of standards. This standards program is carried out in accordance with the principles in DOE Order 1300.2, Department of Energy Standards Program, December 18, 1980. The purposes of this effort, as set forth in three subtasks, are to (1) manage the NE Standards Program, (2) manage the development and maintenance of NE standards, and (3) operate an NE Standards Information Program. This report assesses the Performance Assurance Project Office (PAPO) activities in terms of the objectives of the Department of Energy-Nuclear Energy (DOE-NE) funded programs. To meet these objectives, PAPO administers a nuclear standards program and related activities and fosters the development and application of standards. This task is carried out in accordance with the principles set forth in DOE Order 1300.2, Department of Energy Standards Program, December 18, 1980, and DOE memorandum, Implementation of DOE Orders on Quality Assurance, Standards, and Unusual Occurrence Reporting for Nuclear Energy Programs, March 3, 1982, and with guidance from the DOE-NE Technology Support Programs. 1 tab. (JF)

  7. Grain Elevators: New Source Performance Standards (NSPS)

    Science.gov (United States)

    The New Source Performance Standards (NSPS) for Grain Elevators aims to reduce particulate matter pollution. The new amendments seek to clarify definitions, and requirements, as well as propose new regulations on particulate matter emissions

  8. Advanced Performance Hydraulic Wind Energy

    Science.gov (United States)

    Jones, Jack A.; Bruce, Allan; Lam, Adrienne S.

    2013-01-01

    The Jet Propulsion Laboratory, California Institute of Technology, has developed a novel advanced hydraulic wind energy design, which has up to 23% performance improvement over conventional wind turbine and conventional hydraulic wind energy systems with 5 m/sec winds. It also has significant cost advantages with levelized costs equal to coal (after carbon tax rebate). The design is equally applicable to tidal energy systems and has passed preliminary laboratory proof-of-performance tests, as funded by the Department of Energy.

  9. Procedure for Measuring and Reporting Commercial Building Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    Barley, D.; Deru, M.; Pless, S.; Torcellini, P.

    2005-10-01

    This procedure is intended to provide a standard method for measuring and characterizing the energy performance of commercial buildings. The procedure determines the energy consumption, electrical energy demand, and on-site energy production in existing commercial buildings of all types. The performance metrics determined here may be compared against benchmarks to evaluate performance and verify that performance targets have been achieved.

  10. Procedure to Measure Indoor Lighting Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    Deru, M.; Blair, N.; Torcellini, P.

    2005-10-01

    This document provides standard definitions of performance metrics and methods to determine them for the energy performance of building interior lighting systems. It can be used for existing buildings and for proposed buildings. The primary users for whom these documents are intended are building energy analysts and technicians who design, install, and operate data acquisition systems, and who analyze and report building energy performance data. Typical results from the use of this procedure are the monthly and annual energy used for lighting, energy savings from occupancy or daylighting controls, and the percent of the total building energy use that is used by the lighting system. The document is not specifically intended for retrofit applications. However, it does complement Measurement and Verification protocols that do not provide detailed performance metrics or measurement procedures.

  11. 24 CFR 115.206 - Performance assessments; Performance standards.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Performance assessments; Performance standards. 115.206 Section 115.206 Housing and Urban Development Regulations Relating to Housing... AGENCIES Certification of Substantially Equivalent Agencies § 115.206 Performance assessments; Performance...

  12. Motivational Implications of Faculty Performance Standards

    Science.gov (United States)

    Hardre, Patricia L.; Kollmann, Sherry L.

    2012-01-01

    Expectations and how they are communicated influence employees' motivation, effort, goals, efficacy and performance. This study examined faculty performance evaluation standards and processes of 60 academic departments in research universities for motivationally relevant elements. Characteristics were systematically analysed to understand their…

  13. 77 FR 19008 - Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family Energy...

    Science.gov (United States)

    2012-03-29

    .... The development of the Guidelines for Home Energy Professionals: Standard Work Specifications for... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family Energy Upgrades AGENCY: Office of Energy...

  14. 10 CFR 440.21 - Weatherization materials standards and energy audit procedures.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Weatherization materials standards and energy audit... FOR LOW-INCOME PERSONS § 440.21 Weatherization materials standards and energy audit procedures. (a...) of this section describes the performance and quality standards for renewable energy systems...

  15. Windows with improved energy performance

    DEFF Research Database (Denmark)

    Noyé, Peter Anders; Laustsen, Jacob Birck; Svendsen, Svend

    2002-01-01

    According to the Danish energy protocol, Energy 21, one of the goals with highest priority is to reduce the CO2-emission. Energy consumption for domestic heating is a major contributor to the CO2-emission; hence one of the primary efforts to reach the goal is by saving energy in the households...... performances. During the last 20 years the U-value of the glazing part of windows has been improved considerably, but the frame part has not followed the same development with respect to energy performance. Therefore an increasingly large part of the total heat loss through windows is relating to the frame...... part, for which reason, as far as energy efficiency and total economy are concerned, it has become more interesting to further develop frame structures. Traditionally, the energy performance of windows has primarily been characterised by the heat loss coefficient, U-value. However as the heat loss has...

  16. Universal standard for the smart energy home

    International Nuclear Information System (INIS)

    Hatler, M.

    2009-01-01

    Smart metering systems are now being installed in countries throughout the world. This article discussed technologies designed to connect in-home electrical devices such as thermostats, energy displays, and computers to the electricity grid. The smart-grid connected devices will form part of the home area network (HAN) designed to provide consumers with real time control of their energy use. Many governments are now mandating the use of HAN interfaces, and members of the energy industry are developing global standards for HANs. Within 5 years, it is estimated that over 126 million smart meters will be installed in households worldwide. Using HANs, consumers will be able to shift their usage away from peak energy usage times that are more expensive. Studies have demonstrated that the use of dynamic pricing options can result in a 50 per cent load reduction during critical peak periods. A universal standard and certification process is currently underway to prevent HAN market fragmentation and to ensure plug-and-play interoperability among HAN devices. It was concluded that the smart energy home will present large market opportunities for software developers, investors, and manufacturers. 1 fig

  17. Energy plus standard in buildings constructed by housing associations?

    International Nuclear Information System (INIS)

    Stutterecker, Werner; Blümel, Ernst

    2012-01-01

    In order to achieve national, European and international energy goals, energy efficiency strategies in the building sector have to be implemented. The passive house standard and low energy standards are already successfully established in single dwelling houses. These high performance standards are starting to penetrate into the sector of housing associations. A case study about an apartment building constructed by a housing association is presented here. It describes the monitoring concept and the results of the 1st year of monitoring. Depending on the definition of the zero energy building standard (extent of loads included in the balancing), the building could be classified as an energy plus building or as a building, which uses more energy, than is supplied by on-site generation. If the building's total energy use (including user specific loads) is defined as load, only 34.5% of these loads were provided by the net energy output of the PV system. If only the heating energy demand is defined as load, the PV system even yielded a surplus of 45.6% of the energy load. -- Highlights: ► Energy monitoring of an apartment building constructed by a housing association. ► Planned as a Passive House with a semi-central ventilation system with decentralized heat pump technology. ► Total end energy demand of the building was 43 kWh/(m² a). ► Total net energy generation by the PV system was 15 kWh/(m² a). ► Apartment no. 1: 52% of the energy demand were used for heating and ventilation.

  18. DOE technical standards list. Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listing of current DOE technical standards, non-Government standards that have been adopted by DOE, other Government documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  19. Testing of camera performance standards at steady and local overloading

    International Nuclear Information System (INIS)

    Keszthelyine Landori, S.; Adorjanne Farkas, M.; Csirik, J.

    1983-01-01

    Camera performance standards are usually given for low count rates and uniform irradiation. A conventional analog gamma camera system (Gamma MB 9100 manufactured under the know-how of Picker DC 4/12 in Hungary) was studied on the basis of the Picker test procedure and the NEMA standard system. Uniformity, linearity, spatial and energy resolution were measured at high count rates and uniform irradiation (steady overloading). Linearity was studied at local overloading. Linearity, spatial and energy resolution were measured by a 1024-channel analyzer-computer system of KFKI, Hungary. The data were evaluated on the basis of NEMA standards, while uniformity was measured by the Gamma data processing system and evaluated by special SEGAMS programs. Performance variations were studied between 7500 cps and 75.000 cps pulse rates. Spatial and energy resolution were influenced strongly, uniformity slightly by pulse rates, while linearity did not change at all. Linearity was not influenced even by local overloading. (author)

  20. Windows with improved energy performances

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2003-01-01

    Heat loss through windows represents a considerable part of the total heat loss from houses. However, apart from providing daylight access and view, windows offer a unique potential for solar gain to be exploited during the heating season. Until now valuation of the energy performance of windows...... has primary focused on the heat loss coefficient, U-value. However, as the U-value, especially for the glazing part, has improved considerably during the last years, the total solar energy transmittance, g-value, has become equally important to the total energy performance of windows. Improved energy...... resulted in a window with a positive net energy gain (in short the Net Gain Window), which means that it contributes to the space heating of the building. All improvements are based on existing technology and manufacturing methods. The results from this work show that the energy performances of windows can...

  1. Community-Wide Zero Energy Ready Home Standard

    Energy Technology Data Exchange (ETDEWEB)

    Herk, A. [IBACOS, Inc., Pittsburgh, PA (United States); Beggs, T. [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-05

    This report outlines the steps a developer can take when creating and implementing high performance standards such as the U.S. Department of Energy’s (DOE’s) Zero Energy Ready Home (ZERH) standards on a community-wide scale. The report also describes the specific examples of how this process is underway in the Stapleton community in Denver, Colorado, by the developer Forest City.

  2. Community-Wide Zero Energy Ready Home Standard

    Energy Technology Data Exchange (ETDEWEB)

    Herk, A. [IBACOS, Inc., Pittsburght, PA (United States); Beggs, T. [IBACOS, Inc., Pittsburght, PA (United States)

    2016-02-05

    This report outlines the steps a developer can use when looking to create and implement higher performance standards such as the U.S. Department of Energy (DOE) Zero Energy Ready Home (ZERH) standards in a community. The report also describes the specific examples of how this process was followed by a developer, Forest City, in the Stapleton community in Denver, Colorado. IBACOS described the steps used to begin to bring the DOE ZERH standard to the Forest City Stapleton community based on 15 years of community-scale development work done by IBACOS. As a result of this prior IBACOS work, the team gained an understanding of the various components that a master developer needs to consider and created strategies for incorporating those components in the initial phases of development to achieve higher performance buildings in the community. An automated scoring system can be used to perform an internal audit that provides a detailed and consistent evaluation of how several homes under construction or builders' floor plans compare with the requirements of the DOE Zero Energy Ready Home program. This audit can be performed multiple times at specific milestones during construction to allow the builder to make changes as needed throughout construction for the project to meet Zero Energy Ready Home standards. This scoring system also can be used to analyze a builder's current construction practices and design.

  3. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This technical standards list (TSL) was prepared for use by personnel involved in the selection and use of US DOE technical standards and other government and non-government standards. This TSL provides listings of current DOE technical standards, non-government standards that have been adopted by DOE, other government documents in which DOE has a recorded interest, and cancelled DOE technical standards. Standards are indexed by type in the appendices to this document. Definitions of and general guidance for the use of standards are also provided.

  4. Energy performance evaluation of AAC

    Science.gov (United States)

    Aybek, Hulya

    The U.S. building industry constitutes the largest consumer of energy (i.e., electricity, natural gas, petroleum) in the world. The building sector uses almost 41 percent of the primary energy and approximately 72 percent of the available electricity in the United States. As global energy-generating resources are being depleted at exponential rates, the amount of energy consumed and wasted cannot be ignored. Professionals concerned about the environment have placed a high priority on finding solutions that reduce energy consumption while maintaining occupant comfort. Sustainable design and the judicious combination of building materials comprise one solution to this problem. A future including sustainable energy may result from using energy simulation software to accurately estimate energy consumption and from applying building materials that achieve the potential results derived through simulation analysis. Energy-modeling tools assist professionals with making informed decisions about energy performance during the early planning phases of a design project, such as determining the most advantageous combination of building materials, choosing mechanical systems, and determining building orientation on the site. By implementing energy simulation software to estimate the effect of these factors on the energy consumption of a building, designers can make adjustments to their designs during the design phase when the effect on cost is minimal. The primary objective of this research consisted of identifying a method with which to properly select energy-efficient building materials and involved evaluating the potential of these materials to earn LEED credits when properly applied to a structure. In addition, this objective included establishing a framework that provides suggestions for improvements to currently available simulation software that enhance the viability of the estimates concerning energy efficiency and the achievements of LEED credits. The primary objective

  5. Hearing protector performance and standard deviation.

    Science.gov (United States)

    Williams, W; Dillon, H

    2005-01-01

    The attenuation performance of a hearing protector is used to estimate the protected exposure level of the user. The aim is to reduce the exposed level to an acceptable value. Users should expect the attenuation to fall within a reasonable range of values around a norm. However, an analysis of extensive test data indicates that there is a negative relationship between attenuation performance and the standard deviation. This result is deduced using a variation in the method of calculating a single number rating of attenuation that is more amenable to drawing statistical inferences. As performance is typically specified as a function of the mean attenuation minus one or two standard deviations from the mean to ensure that greater than 50% of the wearer population are well protected, the implication of increasing standard deviation with decreasing attenuation found in this study means that a significant number of users are, in fact, experiencing over-protection. These users may be disinclined to use their hearing protectors because of an increased feeling of acoustic isolation. This problem is exacerbated in areas with lower noise levels.

  6. Environmental assessment in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 7

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-09-01

    The objective of this environmental assessment (EA) is to identify the potential environmental impacts that could result from the proposed voluntary residential standard (VOLRES) on private sector construction of new residential buildings. In this report, the scope, objectives, and approach of this EA are presented.

  7. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  8. 77 FR 52553 - Standards of Performance for Stationary Gas Turbines; Standards of Performance for Stationary...

    Science.gov (United States)

    2012-08-29

    ... still perform the traditional reconstruction analysis, i.e., the owner/operator would compare the total... blending to achieve the applicable SO 2 standard. Under the proposed language, an owner/operator of an...

  9. Global Potential of Energy Efficiency Standards and Labeling Programs

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Michael A; McNeil, Michael A.; Letschert, Virginie; de la Rue du Can, Stephane

    2008-06-15

    This report estimates the global potential reductions in greenhouse gas emissions by 2030 for energy efficiency improvements associated with equipment (appliances, lighting, and HVAC) in buildings by means of energy efficiency standards and labels (EES&L). A consensus has emerged among the world's scientists and many corporate and political leaders regarding the need to address the threat of climate change through emissions mitigation and adaptation. A further consensus has emerged that a central component of these strategies must be focused around energy, which is the primary generator of greenhouse gas emissions. Two important questions result from this consensus: 'what kinds of policies encourage the appropriate transformation to energy efficiency' and 'how much impact can these policies have'? This report aims to contribute to the dialogue surrounding these issues by considering the potential impacts of a single policy type, applied on a global scale. The policy addressed in this report is Energy Efficient Standards and Labeling (EES&L) for energy-consuming equipment, which has now been implemented in over 60 countries. Mandatory energy performance standards are important because they contribute positively to a nation's economy and provide relative certainty about the outcome (both timing and magnitudes). Labels also contribute positively to a nation's economy and importantly increase the awareness of the energy-consuming public. Other policies not analyzed here (utility incentives, tax credits) are complimentary to standards and labels and also contribute in significant ways to reducing greenhouse gas emissions. We believe the analysis reported here to be the first systematic attempt to evaluate the potential of savings from EES&L for all countries and for such a large set of products. The goal of the analysis is to provide an assessment that is sufficiently well-quantified and accurate to allow comparison and integration

  10. Standardized performance tests of collectors of solar thermal energy-a flat-plate collector with a single-tube serpentine flow distribution

    Science.gov (United States)

    Johnson, S.

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.

  11. Lighting standards updated. Energy consumption in new standards; Verlichtingsnormen gewijzigd. Energiegebruik in nieuwe normen verwerkt

    Energy Technology Data Exchange (ETDEWEB)

    Visser, R. [Professional Lighting Designers' Association PLDA, Guetersloh (Germany)

    2011-12-15

    For the illumination of workplaces, a new version of the standard NEN-EN 12464-1 (Light and illumination. Lighting for workplaces. Part 1. Indoor workplaces) has been published. Also the Dutch standard NEN 3087 on visual ergonomics is completely revised . Furthermore, the guideline NPR 3437 (Ergonomics. Visual aspects of tinted glazing in the work environment) is repealed. Finally, NEN 2916 is replace by NEN 7120, a standard on energy consumption of lighting in relation to the energy performance of buildings. [Dutch] Voor de verlichting van werkplekken is een nieuwe versie van NEN-EN 12464-1 verschenen (Licht en verlichting. Werkplekverlichting. Deel 1. Werkplekken binnen). Ook is de Nederlandse norm NEN 3087 over visuele ergonomie geheel herzien. Verder is de Praktijkrichtlijn NPR 3437 (Ergonomie. Visuele aspecten van getinte beglazing in de werkomgeving) ingetrokken en is NEN 2916 vervangen door NEN 7120, een norm over het energiegebruik van verlichting in relatie tot de energieprestatie van gebouwen.

  12. Performance profiles of major energy producers, 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-01

    The energy industry generally and petroleum and natural gas operations in particular are frequently reacting to a variety of unsettling forces. Falling oil prices, economic upswings, currency devaluations, increasingly rigorous environmental quality standards, deregulation of electricity markets, and continued advances in exploration and production technology were among the challenges and opportunities to the industry in 1997. To analyze the extent to which these and other developments have affected energy industry financial and operating performance, strategies, and industry structure, the Energy Information Administration (EIA) maintains the Financial Reporting Systems (FRS). Through Form EIA-28, major US energy companies annually report to the FRS. Financial and operating information is reported by major lines of business, including oil and gas production (upstream), petroleum refining and marketing (downstream), other energy operations, and nonenergy business. Performance Profiles of Major Producers 1997 examines the interplays of energy markets, companies` strategies, and government policies (in 1997 and in historical context) that gave rise to the results given here. The report also analyzes other key aspects of energy company financial performance as seen through the multifaceted lens provided by the FRS data and complementary data for industry overall. 41 figs., 77 tabs.

  13. Countermeasures for Developing New Energy Bus Standards in China

    Science.gov (United States)

    Shi, Xin

    2018-01-01

    With the rapid development of new energy vehicle technology, new energy bus has become more and more popular in China, and the relevant standards and policy are urgently needed to guide the market. According to the assessment of the development situation on new energy vehicle technology and new energy bus, combing with traffic policy guidance and the development trend of new energy vehicles, this paper aims to put forward the countermeasures of the new energy bus standard in China, including standard system, key standards and relevant recommendations. Research result is expected to provide decision support for the wide application of new energy bus in China.

  14. 78 FR 37995 - Energy Efficiency Standards for Manufactured Housing

    Science.gov (United States)

    2013-06-25

    ... Efficiency Standards for Manufactured Housing AGENCY: Office of Energy Efficiency and Renewable Energy... in receiving information that relates to the relationship between energy efficiency and indoor air... higher energy efficiencies, and possible enforcement models for the DOE standards. This notice identifies...

  15. 32 CFR 1656.11 - Job performance standards and sanctions.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Job performance standards and sanctions. 1656.11... ALTERNATIVE SERVICE § 1656.11 Job performance standards and sanctions. (a) Standards of Performance. An ASW is..., appearance or performance violates reasonable employer standards; or (4) He quits or leaves his job without...

  16. The Business Value of Superior Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee; Scheihing, Paul; Evans, Tracy; Glatt, Sandy; Meffert, William

    2015-08-04

    Industrial facilities participating in the U.S. Department of Energy’s (US DOE) Superior Energy Performance (SEP) program are finding that it provides them with significant business value. This value starts with the implementation of ISO 50001-Energy management system standard, which provides an internationally-relevant framework for integration of energy management into an organization’s business processes. The resulting structure emphasizes effective use of available data and supports continual improvement of energy performance. International relevance is particularly important for companies with a global presence or trading interests, providing them with access to supporting ISO standards and a growing body of certified companies representing the collective knowledge of communities of practice. This paper examines the business value of SEP, a voluntary program that builds on ISO 50001, inviting industry to demonstrate an even greater commitment through third-party verification of energy performance improvement to a specified level of achievement. Information from 28 facilities that have already achieved SEP certification will illustrate key findings concerning both the value and the challenges from SEP/ISO 50001 implementation. These include the facilities’ experience with implementation, internal and external value of third-party verification of energy performance improvement; attractive payback periods and the importance of SEP tools and guidance. US DOE is working to bring the program to scale, including the Enterprise-Wide Accelerator (SEP for multiple facilities in a company), the Ratepayer-Funded Program Accelerator (supporting tools for utilities and program administrators to include SEP in their program offerings), and expansion of the program to other sectors and industry supply chains.

  17. 77 FR 23238 - Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family Energy...

    Science.gov (United States)

    2012-04-18

    ...: Comments on the Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family Energy Upgrades AGENCY: Office of Energy...

  18. 77 FR 2355 - Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and...

    Science.gov (United States)

    2012-01-17

    ... advantages; distributive impacts; and equity); (4) to the extent feasible, specify performance objectives... Defense Council (NRDC), the Northwest Energy Efficiency Alliance (NEEA), and the Northwest Power and... Strategic Plan commits the Department to reviewing minimum appliance efficiency standards at least every 5...

  19. 77 FR 59712 - Energy Conservation Program: Energy Conservation Standards for Dishwashers

    Science.gov (United States)

    2012-10-01

    ... amended energy conservation standards, DOE conducted a market survey using all available public... Energy Conservation Program: Energy Conservation Standards for Dishwashers AGENCY: Office of Energy... establish amended energy conservation standards for dishwashers in the Federal Register on May 30, 2012. DOE...

  20. 40 CFR 415.115 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY Potassium Metal Production... achieve the following new source performance standards (NSPS): There shall be no discharge of process...

  1. Energy performance assessment in urban planning competitions

    International Nuclear Information System (INIS)

    Eicker, Ursula; Monien, Dirk; Duminil, Éric; Nouvel, Romain

    2015-01-01

    Highlights: • Quantification of energy efficiency in urban planning. • Analysis based on 3D (city) model. • Impact evaluation of urban form on energy demand, supply and building costs. • Primary energy balance with and without inclusion of shadowing effects. - Abstract: Many cities today are committed to increase the energy efficiency of buildings and the fraction of renewables especially in new urban developments. However, quantitative data on building energy performance as a function of urban density, building compactness and orientation, building use and supply options are rarely available during the design of new cities or early scenario analysis for existing city quarters, making it difficult for cities to effectively evaluate which concepts work today and in the future. The paper proposes a methodology to assess the energy demand and supply options as a function of the availability of geometry, building standard and use data. An automated procedure was implemented to identify each building’s geometry and volume and transfer the information to a simulation tool, which then calculates heating demand and solar energy generation on roofs and facades. The simulation includes shading calculations for each segment of the façades and roofs and thus allows a very detailed quantification of the building energy demand. By applying the methodology to a case study city quarter designed in an urban competition in Munich, it could be shown how the urban design influences the energy demand of the quarter and which fractions of renewable energy can be integrated into the roofs. While the building insulation standard and use are the is most important criteria for building energy efficiency (with an impact of more than a factor 2), the exact geometrical form, compactness and urban shading effects influences the energy demand by 10–20%. On the other hand, the detailed roof geometry and orientation influences the possible solar coverage of electricity or thermal

  2. Load carriage, human performance, and employment standards.

    Science.gov (United States)

    Taylor, Nigel A S; Peoples, Gregory E; Petersen, Stewart R

    2016-06-01

    The focus of this review is on the physiological considerations necessary for developing employment standards within occupations that have a heavy reliance on load carriage. Employees within military, fire fighting, law enforcement, and search and rescue occupations regularly work with heavy loads. For example, soldiers often carry loads >50 kg, whilst structural firefighters wear 20-25 kg of protective clothing and equipment, in addition to carrying external loads. It has long been known that heavy loads modify gait, mobility, metabolic rate, and efficiency, while concurrently elevating the risk of muscle fatigue and injury. In addition, load carriage often occurs within environmentally stressful conditions, with protective ensembles adding to the thermal burden of the workplace. Indeed, physiological strain relates not just to the mass and dimensions of carried objects, but to how those loads are positioned on and around the body. Yet heavy loads must be borne by men and women of varying body size, and with the expectation that operational capability will not be impinged. This presents a recruitment conundrum. How do employers identify capable and injury-resistant individuals while simultaneously avoiding discriminatory selection practices? In this communication, the relevant metabolic, cardiopulmonary, and thermoregulatory consequences of loaded work are reviewed, along with concomitant impediments to physical endurance and mobility. Also emphasised is the importance of including occupation-specific clothing, protective equipment, and loads during work-performance testing. Finally, recommendations are presented for how to address these issues when evaluating readiness for duty.

  3. Standard Guide for Specifying Thermal Performance of Geothermal Power Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers power plant performance terms and criteria for use in evaluation and comparison of geothermal energy conversion and power generation systems. The special nature of these geothermal systems makes performance criteria commonly used to evaluate conventional fossil fuel-fired systems of limited value. This guide identifies the limitations of the less useful criteria and defines an equitable basis for measuring the quality of differing thermal cycles and plant equipment for geothermal resources. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. 12 CFR 345.26 - Small bank performance standards.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Small bank performance standards. 345.26... GENERAL POLICY COMMUNITY REINVESTMENT Standards for Assessing Performance § 345.26 Small bank performance standards. (a) Performance criteria—(1) Small banks that are not intermediate small banks. The FDIC...

  5. Worldwide status of energy standards for buildings: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Janda, K.B.; Busch, J.F.

    1993-02-01

    This informal survey was designed to gain information about the worldwide status of energy efficiency standards for buildings, particularly non-residential buildings such as offices, schools, and hotels. The project has three goals: 1. To understand and learn from the experience of countries with existing building energy standards; 2. To locate areas where these lessons might be applied and energy standards might be effectively proposed and developed; and 3. To share the information gathered with all participating countries. These appendices include the survey cover letter, the survey, and the details of selected energy standards in 35 countries, thus providing supporting material for the authors` article of the same title.

  6. Environment, energy, and economic performance

    Energy Technology Data Exchange (ETDEWEB)

    Oberndorfer, Ulrich

    2009-09-25

    This thesis analyzes the relationship between environmental regulation as well as energy market developments on the one hand, and economic performance on the other. Due to its economic effects environmental regulation is controversially disputed. The thesis shows, however, that the economic impacts of the recently adopted climate policy in Europe, namely of the implementation of the European Union Emission Trading Scheme, have been modest at most. Consistent with economic theory, the low stringency of this regulatory measure that is aimed at combating man-made climate change is identified as one important driver of this result. Moreover, results presented in this thesis also indicate the important role which the political economy plays for the design of environmental regulation in general. These mechanisms are shown to be a driver of the low stringency and, consequently, of the small economic effects during the first phase of the European Union Emission Trading Scheme. The thesis highlights the role of investment stimulation if the goal of environmental regulation is not only the protection of the environment, but also the compatibility with economic goals. This thesis also provides new insights into the role of energy market developments for the economy. In this respect, the relevance of the EU carbon market for the financial market performance of European electricity generators is shown. Besides, this thesis particularly demonstrates the paramount importance of oil market developments for the economy as a whole. It suggests that amongst all natural resources, oil is the most relevant one to the pricing of Eurozone energy stocks. It is also shown that besides oil prices, oil volatility plays an important role for stock market development. Finally, the thesis highlights the relevance of oil market developments to the overall economy, in showing that unemployment in Germany is strongly affected by oil price shocks. In this respect, it also opposes claims that the

  7. The energy performance contract - key towards energy efficiency in Europe?

    Directory of Open Access Journals (Sweden)

    Murafa Corina

    2017-07-01

    Full Text Available The paper focuses on the Energy Performance Contract (EPC as a business model for energy efficiency. More precisely, it examines, using two case studies, enablers and disablers – from an economic, legal and institutional/managerial perspective – for advancing this arrangement across the EU. The EU has set a 20% energy savings target by 2020 (roughly equivalent to turning off 400 power stations, with an even more ambitious target of 27% by 2030. To reach these ambitious targets, the investments needed are approximately EUR 100 bn/year across the EU (according to the European Commission. Energy efficiency is not, as fervent proponents often claim, the low hanging fruit in terms of investment efforts. Like any other sub-sector, such as transmission and distribution, it demands innovative financing instruments to ensure adequate scale-up. In the paper, I use two comparative case studies to identify and classify the disablers and enablers of Energy Performance Contracting/Energy Services Companies (ESCOs development: the European frontrunner, namely Germany, and a laggard, namely Romania. As research methodology, I use literature review, comparisons between similar government policy planning and evaluation documents, and stakeholder interviews. While academic literature on the topic (Seefeldt, 2003; Wilhelm, 2015 is developed for Germany, for Romania a critical reflection on EPC promotion policy is to be found only in industry documents (e.g.: ARPEE, 2013; Tractebel, 2015. The German success demonstrates that, contrary to the belief of Romanian stakeholders, it is not the lack of a standardized contract model that prevents EPC development, but lack of genuine commitment, drive and leadership of public officials in promoting this financing instrument. A solid communication between public authorities and private beneficiaries, and public administration capacity for impact assessment and evidence-based policy planning are two other significant

  8. The effect of energy performance regulations on energy consumption

    NARCIS (Netherlands)

    Guerra-Santin, O.; Itard, L.

    2012-01-01

    Governments have developed energy performance regulations in order to lower energy consumption in the housing stock. Most of these regulations are based on the thermal quality of the buildings. In the Netherlands, the energy efficiency for new buildings is expressed as the EPC (energy performance

  9. 78 FR 9631 - Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Residential...

    Science.gov (United States)

    2013-02-11

    ... Efficiency Program for Consumer Products: Energy Conservation Standards for Residential Boilers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of public meeting.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, EE-2J...

  10. IT security standards for the digitalization of the energy transition

    International Nuclear Information System (INIS)

    Laupichler, Dennis

    2016-01-01

    Intelligent measuring systems are important components in the intelligent net and require security and privacy by design in this critical infrastructure. The smart meter gateway as secure communication platform makes the digital sector coupling possible and becomes the driver for innovations of the digitalization. The protection profiles and the technical rules of the BSI as essential part of the law for the digitalization of the energy transition guarantee a great amount of data protection and data security and provide a unique security standard in the future energy supply system. The data -protection concept of the intelligent measuring system regards a calibration-law conformal data processing and star-shaped data dispatch of the gateway. By this both a traceability and a transparency for the final user is guaranteed and the handling of the data in the sense of the data sovereignty is also technically enforced. For the evidences of compliance of the protection profiles and the technical rules correponding tests in approved test centers with final certification by the BSI are performed. The law for the digitalization of the energy transition makes the first important step to an innovative, digital infrastructure of the intelligent net. By the legal framework additionally a base is created, in order to perform a progressive development of the security targets of the BSI both for intelligent measuring systems as for further important system components of the intelligent energy net via a roadmap for the digitalization. In connection with the technical standards of the BSI the law creates the necessary legal certainty and realizes the aim pursued in the coalition treaty to regulate binding framework conditions for the secure and data-protection conformal application of intelligent measuring systems for diversified application cases in the intelligent net.

  11. Recommendations for Autonomous Industrial Vehicle Performance Standards

    OpenAIRE

    Bostelman , Roger

    2016-01-01

    International audience; A workshop was held at the IEEE International Conference on Robotics and Automation, called: “Autonomous Industrial Vehicles: From the Laboratory to the Factory Floor”. Nine research papers were presented followed by a discussion session summarized in this paper. The workshop findings are intended to be useful for developing standards within the ASTM F45 Committee for Driverless Automatic Industrial Vehicles. This paper provides feedback from the discussion listing the...

  12. 12 CFR 228.26 - Small bank performance standards.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Small bank performance standards. 228.26... bank performance standards. (a) Performance criteria—(1) Small banks that are not intermediate small... performance is evaluated pursuant to the following criteria: (1) The bank's loan-to-deposit ratio, adjusted...

  13. 12 CFR 25.26 - Small bank performance standards.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Small bank performance standards. 25.26 Section... § 25.26 Small bank performance standards. (a) Performance criteria—(1) Small banks that are not... lending performance is evaluated pursuant to the following criteria: (1) The bank's loan-to-deposit ratio...

  14. 78 FR 73589 - Energy Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric...

    Science.gov (United States)

    2013-12-06

    ... Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric Motors; Proposed... Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric Motors AGENCY... proposes energy conservation standards for a number of different groups of electric motors that DOE has not...

  15. 40 CFR 415.645 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.645 New source performance standards (NSPS). (a) Any new source subject to this subpart and producing cadmium pigments must achieve the following new source performance standards (NSPS...

  16. 47 CFR 25.209 - Antenna performance standards.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Antenna performance standards. 25.209 Section 25.209 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25.209 Antenna performance standards. (a) The gain of any...

  17. Energy performance of windows based on the net energy gain

    DEFF Research Database (Denmark)

    Svendsen, Svend; Kragh, Jesper; Laustsen, Jacob Birck

    2005-01-01

    The paper presents a new method to set up energy performance requirements and energy classes for windows of all dimensions and configurations. The net energy gain of windows is the solar gain minus the heat loss integrated over the heating season. The net energy gain can be calculated for one...... be expressed as a function of two parameters representing the energy performance and two parameters representing the geometry of the window. The two energy performance parameters are the net energy gain per area of the glazing unit and the sum of the heat losses through the frame and the assembly per length...... of the frame. The two geometry numbers are the area of the glazing unit relative to the window area and the length of the frame profiles relative to the window area. Requirements and classes for the energy performance of the window can be given by assigning values to the two energy performance parameters...

  18. KWOC [Key-Word-Out-of-Context] index of nuclear energy standards

    International Nuclear Information System (INIS)

    Jennings, S.D.

    1990-05-01

    One major task of the Nuclear Standards Program funded by the Department of Energy (DOE)-Nuclear Energy (NE) Technology Support Programs is to promote and support the use of standards by providing line managers and standards coordinators with data that facilitates their ability to utilize standards requirements. To meet this task, the Performance Assurance Project Office (PAPO) administers a Performance Assurance Information Program. The task is carried out in accordance with the principle set forth in DOE Order 1300.2, ''Department of Energy Standards Program,'' December 18, 1980, and DOE memorandum, ''Implementation of DOE Orders on Quality Assurance, Standards, and Unusual Occurrence Reporting for Nuclear Energy Programs,'' March 3, 1982, and with guidance from the DOE-NE Technology Support Programs. The purpose of this information program is to collect, compile, and distribute program-related information, reports, and publications for the benefit of the DOE-NE program participants

  19. Determination analysis of energy conservation standards for distribution transformers

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, P.R.; Van Dyke, J.W.; McConnell, B.W.; Das, S.

    1996-07-01

    This report contains information for US DOE to use in making a determination on proposing energy conservation standards for distribution transformers as required by the Energy Policy Act of 1992. Potential for saving energy with more efficient liquid-immersed and dry-type distribution transformers could be significant because these transformers account for an estimated 140 billion kWh of the annual energy lost in the delivery of electricity. Objective was to determine whether energy conservation standards for distribution transformers would have the potential for significant energy savings, be technically feasible, and be economically justified from a national perspective. It was found that energy conservation for distribution transformers would be technically and economically feasible. Based on the energy conservation options analyzed, 3.6-13.7 quads of energy could be saved from 2000 to 2030.

  20. 75 FR 20111 - Energy Conservation Program: Energy Conservation Standards for Residential Water Heaters, Direct...

    Science.gov (United States)

    2010-04-16

    ... Program: Energy Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and Pool... heating equipment and pool heaters. Table I.1--Amended Energy Conservation Standards for Residential Water... for national energy and water conservation; and 7. Other factors the Secretary of Energy (Secretary...

  1. Standards to develop energy control and energy efficiency in Europe

    International Nuclear Information System (INIS)

    Plazy, J.L.; Moutet, C.

    2007-01-01

    Since the late nineties, an energy control standardisation steering body was set up at the AFNOR, prompted by the French administration and ADEME which is chairing it. That body, which became a forum in 2006 brings together stakeholders in various areas concerned by that issue (industries, construction, transport, environment, services,...) as well as the representatives of main companies, professional organisations and standardisation operators acting in the area / of energy in France. Its purpose is to help exchange information and express needs in terms of standardisation in the area of energy and energy efficiency. On its initiative, the European standardisation committees CEN and CENELEC set up in 2002 an equivalent body responsible for the strategic coordination of their energy management programmes and entrusted the steering to our country (ADEME chairing, AFNOR secretariat). In order to better serve the interests of its members, the French forum is now working towards the leadership, in partnership with China, of the strategic standardisation group being set up at the ISO (International Standardisation Organisation) on energy efficiency and renewable energy sources. (authors)

  2. 77 FR 38743 - Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Battery...

    Science.gov (United States)

    2012-06-29

    ... Efficiency Program for Consumer Products: Energy Conservation Standards for Battery Chargers and External Power Supplies AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION... Energy Efficiency and Renewable Energy, Building Technologies Program, EE-2J, 1000 Independence Avenue SW...

  3. 75 FR 31323 - Energy Efficiency Program: Energy Conservation Standards Furnace Fans: Public Meeting and...

    Science.gov (United States)

    2010-06-03

    .... EERE-2010-BT-STD-0011] RIN 1904-AC22 Energy Efficiency Program: Energy Conservation Standards Furnace Fans: Public Meeting and Availability of the Framework Document AGENCY: Office of Energy Efficiency and... Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies, EE-2J, 1000 Independence...

  4. Considerations in the development of subsurface containment barrier performance standards

    International Nuclear Information System (INIS)

    Dunstan, S.; Zdinak, A.P.; Lodman, D.

    1997-01-01

    The U.S. Department of Energy (DOE) is supporting subsurface barriers as an alternative remedial option for management of contamination problems at their facilities. Past cleanup initiatives have sometimes proven ineffective or extremely expensive. Economic considerations coupled with changing public and regulatory philosophies regarding remediation techniques makes subsurface barriers a promising technology for future cleanup efforts. As part of the initiative to develop subsurface containment barriers as an alternative remedial option, DOE funded MSE Technology Applications, Inc. (MSE) to conduct a comprehensive review to identify performance considerations for the acceptability of subsurface barrier technologies as a containment method. Findings from this evaluation were intended to provide a basis for selection and application of containment technologies to address waste problems at DOE sites. Based on this study, the development of performance standards should consider: (1) sustainable low hydraulic conductivity; (2) capability to meet applicable regulations; (3) compatibility with subsurface environmental conditions; (4) durability and long-term stability; (5) repairability; and (6) verification and monitoring. This paper describes the approach for determining considerations for performance standards

  5. Performance Standards': Utility for Different Uses of Assessments

    Directory of Open Access Journals (Sweden)

    Robert L. Linn

    2003-09-01

    Full Text Available Performance standards are arguably one of the most controversial topics in educational measurement. There are uses of assessments such as licensure and certification where performance standards are essential. There are many other uses, however, where performance standards have been mandated or become the preferred method of reporting assessment results where the standards are not essential to the use. Distinctions between essential and nonessential uses of performance standards are discussed. It is argued that the insistence on reporting in terms of performance standards in situations where they are not essential has been more harmful than helpful. Variability in the definitions of proficient academic achievement by states for purposes of the No Child Left Behind Act of 2001 is discussed and it is argued that the variability is so great that characterizing achievement is meaningless. Illustrations of the great uncertainty in standards are provided.

  6. 47 CFR 80.1101 - Performance standards.

    Science.gov (United States)

    2010-10-01

    ... radiocommunication equipment and systems—General requirements—Methods of testing and required test results,” Edition... Equipment—Keyboard Layouts for Numeric Applications,” First Edition 1976(E). (c) The equipment specified in... Inmarsat system—operational and performance requirements, methods of testing and required test results...

  7. How to estimate realistic energy savings in Energy Performance Certificates

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Altmann, Nagmeh; Berecová, Monika

    Given the fact that most MS use fixed or other kinds of default values as boundary condition input for energy performance calculations, it is not surprising that the calculated energy performance differs from the measured energy consumption. As a consequence, the calculated energy savings due...... stationary calculation tools using monthly average values. The optimum solution for energy performance certificates and calculating realistic energy savings is to have two calculations. One calculation, using default values to calculate the label itself, and one with actual input parameters for calculating...... energy performance before and after implementing energy saving measures. Actual values though, may be difficult to identify, so there is a need to make adaptations to reality easy. Even if actual values are available, there are still issues that cause calculated energy savings to differ from the obtained...

  8. 12 CFR 563e.26 - Small savings association performance standards.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Small savings association performance standards. 563e.26 Section 563e.26 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY COMMUNITY REINVESTMENT Standards for Assessing Performance § 563e.26 Small savings association performance...

  9. 33 CFR 332.5 - Ecological performance standards.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Ecological performance standards..., DEPARTMENT OF DEFENSE COMPENSATORY MITIGATION FOR LOSSES OF AQUATIC RESOURCES § 332.5 Ecological performance... objective and verifiable. Ecological performance standards must be based on the best available science that...

  10. Effective energy planning for improving the enterprise’s energy performance

    Directory of Open Access Journals (Sweden)

    Păunescu Carmen

    2016-09-01

    Full Text Available The global pressing need to protect the environment, save energy and reduce greenhouse gas emissions worldwide has prompted the enterprises to implementing both individual energy saving measures and a more systematic approach to improve the overall enterprise’s energy performance. Energy management is becoming a priority as enterprises strive to reduce energy costs, conform to regulatory requirements, and improve their corporate image. As such, enterprises are encouraged to manage their energy related matters in a systematic manner and a more harmonized way, to ensure continual improvement on their energy efficiency. Despite the increasing interest in energy management standards, a gap persists between energy management literature and current implementation practices. The release of the ISO 50001 international standard was meant to help the organizations develop sound energy management systems and effective process-based energy management structures that could be recognized through third-party certification. Building on the energy management literature and energy management standards, the current paper presents the essential steps the enterprises should take to practically design a sustainable energy management system. Also, by using multiple case studies of enterprises that have implemented an ISO 50001 energy management system, it introduces a structured approach that companies can use to effectively develop their energy planning and improve energy performance. The key components of the enterprise’s energy planning are discussed, as well as practical examples of energy objectives and performance indicators from various industries are offered. The paper shows that by establishing an effective energy planning system, this will efficiently meet demands for achieving energy performance indicators and international certification.

  11. Energy Savings Performance Contract Energy Sales Agreement Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-08-14

    FEMP developed the Energy Savings Performance Contracting Energy Sales Agreement (ESPC ESA) Toolkit to provide federal agency contracting officers and other acquisition team members with information that will facilitate the timely execution of ESPC ESA projects.

  12. Standard free energy of formation of iron iodide

    Science.gov (United States)

    Khandkar, A.; Tare, V. B.; Wagner, J. B., Jr.

    1983-01-01

    An experiment is reported where silver iodide is used to determine the standard free energy of formation of iron iodide. By using silver iodide as a solid electrolyte, a galvanic cell, Ag/AgI/Fe-FeI2, is formulated. The standard free energy of formation of AgI is known, and hence it is possible to estimate the standard free energy of formation of FeI2 by measuring the open-circuit emf of the above cell as a function of temperature. The free standard energy of formation of FeI2 determined by this method is -38784 + 24.165T cal/mol. It is estimated that the maximum error associated with this method is plus or minus 2500 cal/mol.

  13. Developing an Energy Performance Modeling Startup Kit

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2012-10-01

    In 2011, the NAHB Research Center began assessing the needs and motivations of residential remodelers regarding energy performance remodeling. This report outlines: the current remodeling industry and the role of energy efficiency; gaps and barriers to adding energy efficiency into remodeling; and support needs of professional remodelers to increase sales and projects involving improving home energy efficiency.

  14. Intelligence Level Performance Standards Research for Autonomous Vehicles.

    Science.gov (United States)

    Bostelman, Roger B; Hong, Tsai H; Messina, Elena

    2015-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV's). However, performance standards for AGV's and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance.

  15. 75 FR 17036 - Energy Conservation Program: Energy Conservation Standards for Small Electric Motors; Correction

    Science.gov (United States)

    2010-04-05

    ... Conservation Program: Energy Conservation Standards for Small Electric Motors; Correction AGENCY: Office of... standards for small electric motors, which was published on March 9, 2010. In that final rule, the U.S... titled ``Energy Conservation Standards for Small Electric Motors.'' 75 FR 10874. Since the publication of...

  16. 78 FR 54197 - Energy Efficiency Program for Commercial and Industrial Equipment: Energy Conservation Standards...

    Science.gov (United States)

    2013-09-03

    .... EERE-2013-BT-STD-0030] RIN 1904-AD01 Energy Efficiency Program for Commercial and Industrial Equipment: Energy Conservation Standards for Commercial Packaged Boilers AGENCY: Office of Energy Efficiency and..., Office of Energy Efficiency and Renewable Energy, Building Technologies Office, EE-2J, 1000 Independence...

  17. 78 FR 20842 - Energy Conservation Program: Energy Conservation Standards for Residential Clothes Dryers and...

    Science.gov (United States)

    2013-04-08

    ... DeLonghi); energy and environmental advocates (American Council for an Energy Efficient Economy (ACEEE... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EERE-2013-BT-STD-0020] RIN 1904-AC98 Energy Conservation Program: Energy Conservation Standards for Residential Clothes Dryers and Room Air Conditioners...

  18. Performance Limits of Communication with Energy Harvesting

    KAUST Repository

    Znaidi, Mohamed Ridha

    2016-01-01

    In energy harvesting communications, the transmitters have to adapt transmission to the availability of energy harvested during communication. The performance of the transmission depends on the channel conditions which vary randomly due to mobility

  19. A comparative study of performance measurement standards of railway operator

    Directory of Open Access Journals (Sweden)

    Pongjirawut Siripong

    2017-01-01

    Full Text Available The European standard (EN 13816, is one of the widely accepted standards for measuring the quality of public passenger transport (PPT service. EN 13816 indicates 8 measurement criteria, 29 sub-criteria and 193 Key Performance Indicators (KPIs to be used to measure the performance of railway operators. Nowadays, there are other addition criteria beyond EN13816, developed by various organisations. This research firstly aims to explore the service performance measurement of railway operators used by actual railway operators at international level and in Thailand. After an intensive review of performance measurement standards, 9 standards are compiled and compared in terms of criteria, sub-criteria and KPIs using a cluster analysis methodology. The result found additional performance measurement aspects at 2 sub-criteria and 91 KPIs in addition to EN 13816. This research summarized and compared different performance measurement standards to measure service quality of metro rail line.

  20. 20 CFR 404.1643 - Performance accuracy standard.

    Science.gov (United States)

    2010-04-01

    ... DISABILITY INSURANCE (1950- ) Determinations of Disability Performance Standards § 404.1643 Performance... have been in the file but was not included, even though its inclusion does not change the result in the...

  1. 78 FR 51463 - Energy Conservation Program: Energy Conservation Standards for Metal Halide Lamp Fixtures

    Science.gov (United States)

    2013-08-20

    ... merging the metal halide lamp fixture and the high-intensity discharge (HID) lamp rulemakings. This NOPR... Conservation Program: Energy Conservation Standards for Metal Halide Lamp Fixtures; Proposed Rule #0;#0;Federal...: Energy Conservation Standards for Metal Halide Lamp Fixtures AGENCY: Office of Energy Efficiency and...

  2. 75 FR 7556 - Energy Efficiency Standards for Manufactured Housing

    Science.gov (United States)

    2010-02-22

    ... climatic differences should be addressed through a singular energy standard addressing manufactured homes... (e.g., ENERGY STAR) and/or the analysis that DOE should conduct in assessing such programs. (10... has concluded its review. DOE intends to develop a regulatory impact analysis (RIA), also identified...

  3. Performance profiles of major energy producers 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Performance Profiles of Major Energy Producers 1994 is the eighteenth annual report of the Energy Information Administration`s (EIA) Financial Reporting System (FRS). The report examines financial and operating developments in energy markets, with particular reference to the 24 major U.S. energy companies required to report annually on Form EIA-28. Financial information is reported by major lines of business, including oil and gas production, petroleum refining and marketing, other energy operations, and nonenergy businesses. Financial and operating results are presented in the context of energy market developments with a view toward identifying changing corporate strategies and measuring the performance of ongoing operations both in the United States and abroad.

  4. The European Energy Performance of Buildings Directive

    DEFF Research Database (Denmark)

    Petersen, Steffen; Hviid, Christian Anker

    This paper investigates the actual energy use for building operation with the calculated energy use according to the Danish implementation of the European Energy Performance of Buildings Directive (EPBD). This is important to various stakeholders in the building industry as the calculated energy...... performance is used for estimating investment security, operating budgets and for policy making. A case study shows that the actual and calculated energy use is practically the same in an average scenario. In the worst-case uncertainty scenario, the actual energy use is 20 % higher than the corrected...

  5. Impacts of US federal energy efficiency standards for residential appliances

    International Nuclear Information System (INIS)

    Meyers, S.; McMahon, J.E.; McNeil, M.; Liu, X.

    2003-01-01

    This study estimated energy, environmental, and consumer impacts of US federal residential energy efficiency standards taking effect in the 1988-2007 period. These standards have been the subject of in-depth analyses conducted as part of the US Department of Energy's (DOE's) standards rulemaking process. This study drew on those analyses, but updated key data and developed a common framework and assumptions for all of the products. We estimate that the considered standards will reduce residential primary energy consumption and carbon dioxide (CO 2 ) emissions by 8-9% in 2020 compared to the levels expected without any standards. The standards will save a cumulative total of 26-32 EJ (25-30 quads) by the year 2015, and 63 EJ (60 quads) by 2030. The estimated cumulative net present value of consumer benefit amounts to nearly US$80 billion by 2015, and grows to US$130 billion by 2030. The overall benefit/cost ratio of cumulative consumer impacts in the 1987-2050 period is 2.75:1. The cumulative cost of the DOE's program to establish and implement the standards is in the range of US$200-US$250 million. (author)

  6. Energy and architecture: improvement of energy performance in existing buildings

    Energy Technology Data Exchange (ETDEWEB)

    Haase, Matthias; Wycmans, Annemie; Solbraa, Anne; Grytli, Eir

    2011-07-01

    This book aims to give an overview of different aspects of retrofitting existing buildings. The target group is students of architecture and building engineering as well as building professionals. Eight out of ten buildings which we will inhabit in 2050 already exist. This means that a great potential for reducing our carbon footprint lies in the existing building stock. Students from NTNU have used the renovation of a 1950s school building at Linesoeya in Soer-Trondelag as a case to increase their awareness and knowledge about the challenges building professionals need to overcome to unite technical details and high user quality into good environmental performance. The students were invited by the building owners and initiators of LIPA Eco Project to contribute to its development: By retrofitting an existing building to passive house standards and combining this with energy generated on site, LIPA Eco Project aims to provide a hands-on example with regard to energy efficiency, architectural design and craftsmanship for a low carbon society. The overall goal for this project is to raise awareness regarding resource efficiency measures in architecture and particularly in existing building mass.(au)

  7. Environmental assessment. Energy efficiency standards for consumer products

    Energy Technology Data Exchange (ETDEWEB)

    McSwain, Berah

    1980-06-01

    The Energy Policy and Conservation Act of 1975 requires DOE to prescribe energy efficiency standards for 13 consumer products. The Consumer Products Efficiency Standards (CPES) program covers: refrigerators and refrigerator-freezers, freezers, clothes dryers, water heaters, room air conditioners, home heating equipment, kitchen ranges and ovens, central air conditioners (cooling and heat pumps), furnaces, dishwashers, television sets, clothes washers, and humidifiers and dehumidifiers. This Environmental Assessment evaluates the potential environmental and socioeconomic impacts expected as a result of setting efficiency standards for all of the consumer products covered by the CPES program. DOE has proposed standards for eight of the products covered by the Program in a Notice of Proposed Rulemaking (NOPR). DOE expects to propose standards for home heating equipment, central air conditioners (heat pumps only), dishwashers, television sets, clothes washers, and humidifiers and dehumidifiers in 1981. No significant adverse environmental or socioeconomic impacts have been found to result from instituting the CPES.

  8. ELECTRICITY SAVINGS BY IMPLEMENTING ENERGY EFFICIENCY STANDARDS AND LABELS FOR CLOTHES WASHERS IN MALAYSIA

    Directory of Open Access Journals (Sweden)

    ABU SALEH AHMED

    2011-02-01

    Full Text Available Clothes washers being one of the energy consuming household appliances in Malaysia have become a target for energy efficiency improvements. In the present study, a series of experiment investigations have been conducted on six clothes washers of varying capacities. The objectives are to develop the standards and labels. The test has been performed according to IEC (International Electrotechnical Commision clothes washers test specification. Using the experimental data, a baseline standard has been developed by statistical method. From the baseline standards, 10% standards have been developed. The baseline unit energy consumption was calculated to be 32 Wh/kg/cycle (average unit energy consumption of the six models and on the basis of baseline unit, standard unit energy consumption had been proposed to be 29 Wh/kg/cycle. It has been estimated with the introduction of minimum energy efficiency standards for clothes washer 38077037.46 kWh of energy could be saved per year. To develop a comprehensive energy guide labels, three labels had been design, which were star labeling, speedometer labeling and letter bin labeling. A survey was conducted with three different types of labels among the consumers and with the surveys respond, energy guide label of household clothes washers has been proposed for Malaysia. This is result from used of energy-efficient appliances product and is well positioned to promote more widespread efficient improvement.

  9. Office of Codes and Standards resource book. Section 1, Building energy codes and standards

    Energy Technology Data Exchange (ETDEWEB)

    Hattrup, M.P.

    1995-01-01

    The US Department of Energy`s (DOE`s) Office of Codes and Standards has developed this Resource Book to provide: A discussion of DOE involvement in building codes and standards; a current and accurate set of descriptions of residential, commercial, and Federal building codes and standards; information on State contacts, State code status, State building construction unit volume, and State needs; and a list of stakeholders in the building energy codes and standards arena. The Resource Book is considered an evolving document and will be updated occasionally. Users are requested to submit additional data (e.g., more current, widely accepted, and/or documented data) and suggested changes to the address listed below. Please provide sources for all data provided.

  10. 1995 building energy codes and standards workshops: Summary and documentation

    Energy Technology Data Exchange (ETDEWEB)

    Sandahl, L.J.; Shankle, D.L.

    1996-02-01

    During the spring of 1995, Pacific Northwest National Laboratory (PNNL) conducted four two-day Regional Building Energy Codes and Standards workshops across the US. Workshops were held in Chicago, Denver, Rhode Island, and Atlanta. The workshops were designed to benefit state-level officials including staff of building code commissions, energy offices, public utility commissions, and others involved with adopting/updating, implementing, and enforcing building energy codes in their states. The workshops provided an opportunity for state and other officials to learn more about residential and commercial building energy codes and standards, the role of the US Department of Energy and the Building Standards and Guidelines Program at Pacific Northwest National Laboratory, Home Energy Rating Systems (HERS), Energy Efficient Mortgages (EEM), training issues, and other topics related to the development, adoption, implementation, and enforcement of building energy codes. Participants heard success stories, got tips on enforcement training, and received technical support materials. In addition to receiving information on the above topics, workshop participants had an opportunity to provide input on code adoption issues, building industry training issues, building design issues, and exemplary programs across the US. This paper documents the workshop planning, findings, and follow-up processes.

  11. Commercial Buildings Energy Performance within Context

    DEFF Research Database (Denmark)

    Lazarova-Molnar, Sanja; Kjærgaard, Mikkel Baun; Shaker, Hamid Reza

    2015-01-01

    Existing commercial buildings represent a challenge in the energy efficiency domain. Energy efficiency of a building, very often equalized to a building’s performance should not be observed as a standalone issue. For commercial buildings, energy efficiency needs to be observed and assessed within...

  12. Performance profiles of major energy producers 1989

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-23

    Performance Profiles of Major Energy Producers 1989 is the thirteenth annual report of the Energy Information Administration's (EIA) Financial Reporting System (FRS). The report examines financial and operating developments, with particular reference to the 23 major energy companies (the FRS companies'') required to report annually on Form EIA-28. Financial information is reported by major lines of business including oil and gas production, petroleum refining and marketing, and other energy operations. Domestic and international operations are examined separately in this report. It also traces key developments affecting the financial performance of major energy companies in 1989, as well as review of important trends.

  13. Performance profiles of major energy producers, 1991

    International Nuclear Information System (INIS)

    1992-01-01

    Performance Profiles of Major Energy Producers 1991 is the fifteenth annual report of the Energy Information Administration's (EIA) Financial Reporting System (FRS). The report examines financial and operating developments, with particular reference to the 23 major energy companies (the FRS companies) required to report annually on Form EIA-28. It also traces key developments affecting the financial performance of major energy companies in 1991, as well as reviews important trends. Financial information is reported by major lines of business including oil and gas production, petroleum refining and marketing, and other energy operations. Domestic and international operations are examined separately in this report

  14. 78 FR 72533 - Energy Conservation Program: Energy Conservation Standards for Certain Consumer Products

    Science.gov (United States)

    2013-12-03

    ... published on October 23, 2013. That final rule adopted changes to definitions and energy conservation... revised definition and revised energy conservation standards for small duct high velocity central air... Congress has provided in the AEMTCA for the Secretary of Energy to revise definitions and energy...

  15. 77 FR 32307 - Energy Conservation Program: Energy Conservation Standards for Residential Clothes Washers

    Science.gov (United States)

    2012-05-31

    ... energy conservation standards for various consumer products and certain commercial and industrial... Efficiency Levels 5. Proprietary Designs 6. Reverse Engineering D. Markups Analysis E. Energy and Water Use... per-cycle hot water energy consumption; (2) the total weighted per-cycle machine electrical energy...

  16. Economic analysis of passive houses and low-energy houses compared with standard houses

    International Nuclear Information System (INIS)

    Audenaert, A.; Cleyn, S.H. de; Vankerckhove, B.

    2008-01-01

    As the energy demand used for space heating accounts for 78% of EU15 household delivered energy consumption, significant reductions in energy demand can be achieved by promoting low-energy buildings. Our study investigates three building types: the standard house, the low-energy house and the passive house. As more far-reaching measures concerning energy savings usually lead to higher investments, the aim of our study is to perform an economic analysis in order to determine the economic viability of the three building types

  17. 10 CFR 430.34 - Energy and water conservation standards amendments

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy and water conservation standards amendments 430.34 Section 430.34 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Energy and Water Conservation Standards § 430.34 Energy and water conservation standards...

  18. HSTL IO Standard Based Energy Efficient Multiplier Design using Nikhilam Navatashcaramam Dashatah on 28nm FPGA

    DEFF Research Database (Denmark)

    Madhok, Shivani; Pandey, Bishwajeet; Kaur, Amanpreet

    2015-01-01

    standards. Frequency scaling is one of the best energy efficient techniques for FPGA based VLSI design and is used in this paper. At the end we can conclude that we can conclude that there is 23-40% saving of total power dissipation by using SSTL IO standard at 25 degree Celsius. The main reason for power...... consumption is leakage power at different IO Standards and at different frequencies. In this research work only FPGA work has been performed not ultra scale FPGA....

  19. Energy policy and energy market performance: The Argentinean case

    International Nuclear Information System (INIS)

    Recalde, Marina

    2011-01-01

    In the early 1990s Argentina liberalized and privatized the energy system, trending to a total market oriented system and abandoning the use of energy policy. Since 2004, as a result of a boom in energy demand and constrains in energy supply, Argentina has gone through an energy problem mainly related to natural gas and electricity, which derived in energy shutdowns. In this frame, this study explores the role of energy policy and institutions in Argentina, with the aim of discussing whether it has been properly used to contrast the observed lack of coordination between fossil energy reserves management and the demand of fuels in power generation. The results of the analysis enhance the relevance of regulatory and control authorities, as well as the active use of long run energy policy for the energy system performance in order to avoid coordination failures between subsectors of the system. The relevance of energy consumption for the development process, and the particular characteristics of energy systems require a wide planning perspective. - Highlights: → This paper examines some aspects of the performance of the Argentinean energy system and energy policy. → There is a lack of coordination between fossil energy reserves management and electricity demand. → It is required an improvement of the regulatory framework, and an active role of the regulatory authorities. → A better planning for electricity supply and strengthening aspects related to the linking with other energy chains. → Promoting a systematic exploitation of NG and oil reserves' and increasing the share of RETs in the energy mix.

  20. DOE standard: The Department of Energy Laboratory Accreditation Program administration

    International Nuclear Information System (INIS)

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP), organizational responsibilities, and the accreditation process. DOELAP evaluates and accredits personnel dosimetry and radiobioassay programs used for worker monitoring and protection at DOE and DOE contractor sites and facilities as required in Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection. The purpose of this technical standard is to establish procedures for administering DOELAP and acquiring accreditation

  1. 77 FR 8525 - Energy Conservation Program: Energy Conservation Standards for Standby Mode and Off Mode for...

    Science.gov (United States)

    2012-02-14

    ... way of representing consumer NPV), and (2) the monetary value of the benefits of emission reductions... standards to the Nation (energy savings, positive NPV of consumer benefits, consumer LCC savings, and... and Conservation Act (EPCA) prescribes energy conservation standards for various consumer products and...

  2. 75 FR 12144 - Energy Conservation Program for Consumer Products: Energy Conservation Standards for Residential...

    Science.gov (United States)

    2010-03-15

    .... 1. Consensus Agreement On January 26, 2010, the Air-Conditioning, Heating and Refrigeration... subsections. B. History of the Standards Rulemaking for Residential Furnaces 1. Background Energy conservation... recommending minimum energy conservation standards for residential central air conditioners, heat pumps, and...

  3. 76 FR 22324 - Energy Conservation Program: Energy Conservation Standards for Residential Clothes Dryers and...

    Science.gov (United States)

    2011-04-21

    ... standards, the current standards for room air conditioners and clothes dryers, and the history of the... Residential Clothes Dryers and Room Air Conditioners AGENCY: Office of Energy Efficiency and Renewable Energy... equipment, including residential clothes dryers and room air conditioners. EPCA also requires the U.S...

  4. 77 FR 10997 - Energy Conservation Program: Energy Conservation Standards for Distribution Transformers; Correction

    Science.gov (United States)

    2012-02-24

    ... Conservation Program: Energy Conservation Standards for Distribution Transformers; Correction AGENCY: Office of... standards for distribution transformers. It was recently discovered that values in certain tables of the...,'' including distribution transformers. The Energy Policy Act of 1992 (EPACT 1992), Public Law 102-486, amended...

  5. 78 FR 16443 - Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Ceiling Fans...

    Science.gov (United States)

    2013-03-15

    ... Standards for Ceiling Fans and Ceiling Fan Light Kits AGENCY: Office of Energy Efficiency and Renewable... consider amending the energy conservation standards for ceiling fans and ceiling fan light kits. DOE also....gov . Follow the instructions for submitting comments. Email: CeilingFan[email protected

  6. 40 CFR 415.345 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true New source performance standards (NSPS). 415.345 Section 415.345 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY Chrome Pigments Production...

  7. 40 CFR 425.74 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.74 Section 425.74 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Shearling Subcategory § 425.74...

  8. 40 CFR 425.24 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.24 Section 425.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan, Retan-Wet...

  9. 40 CFR 425.34 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.34 Section 425.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save or Pulp, Non-Chrome...

  10. 40 CFR 425.44 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.44 Section 425.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Retan-Wet Finish-Sides...

  11. 40 CFR 425.94 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.94 Section 425.94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Retan-Wet Finish-Splits...

  12. 40 CFR 425.84 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.84 Section 425.84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Pigskin Subcategory § 425.84 New...

  13. 40 CFR 425.64 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.64 Section 425.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Through-the-Blue Subcategory...

  14. 40 CFR 425.54 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.54 Section 425.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY No Beamhouse Subcategory § 425...

  15. 40 CFR 425.14 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.14 Section 425.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan, Retan-Wet...

  16. 40 CFR 471.103 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... achieve the following new source performance standards (NSPS). The mass of pollutants in the metal powder process wastewater shall not exceed the following values: (a) Metal powder production atom-ization... GUIDELINES AND STANDARDS NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY Metals Powders...

  17. 40 CFR 471.73 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY Uranium Forming... achieve the following new source performance standards (NSPS). The mass of pollutants in the uranium... mg/off-kg (pounds per million off-pounds) of uranium extruded Cadmium 0.007 0.003 Chromium 0.013 0...

  18. Policy Pathways: Energy Performance Certification of Buildings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Improving energy efficiency is one of the most effective measures to address energy security, climate change and economic objectives. The Policy Pathways series can help countries capture this potential by assisting with the implementation of the 25 energy efficiency policy recommendations that were published by the International Energy Agency (IEA) in 2008. This policy pathway on energy performance certification of buildings is the second in the series. It aims to provide a 'how-to' guide to policy makers and relevant stakeholders on the essential elements in implementing energy performance certification of buildings programmes. Energy performance certification of buildings is a way to rate the energy efficiency of individual buildings -- whether they be residential, commercial or public. It is a key policy instrument that can assist governments in reducing energy consumption in buildings. This policy pathway showcases experiences from countries around the world to show examples of good practice and delivers a pathway of ten critical steps to implement energy performance certification of buildings programmes.

  19. Performance profiles of major energy producers 1993

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    Performance Profiles of Major Energy Producers 1993 is the seventeenth annual report of the Energy Information Administration`s (EIA) Financial Reporting System (FRS). The report examines financial and operating developments in energy markets, with particular reference to the 25 major US energy companies required to report annually on Form EIA-28. Financial information is reported by major liens of business, including oil and gas production, petroleum refining and marketing, other energy operations, and nonenergy businesses. Financial and operating results are presented in the context of energy market developments with a view toward identifying changing corporate strategies and measuring the performance of ongoing operations both in the US and abroad. This year`s report analyzes financial and operating developments for 1993 (Part 1: Developments in 1993) and also reviews key developments during the 20 years following the Arab Oil Embargo of 1973--1974 (Part 2: Major Energy Company Strategies Since the Arab Oil Embargo). 49 figs., 104 tabs.

  20. Performance profiles of major energy producers 1992

    International Nuclear Information System (INIS)

    1994-01-01

    Performance Profiles of Major Energy Producers 1992 is the sixteenth annual report of the Energy Information Administration's (EIA) Financial Reporting System (FRS). The report examines financial and operating developments, with particular reference to the 25 major energy companies (the FRS companies) required to report annually on Form EIA-28. Financial information is reported by major lines of business, including oil and gas production, petroleum refining and marketing, and other energy operations. Domestic and international operations are examined separately in this report. The data are presented in the context of key energy market developments with a view toward identifying changing strategies of corporate development and measuring the apparent success of current ongoing operations

  1. COMPETITIVE ADVANTAGES THROUGH THE IMPLEMENTATION OF INTERNATIONAL ENERGY MANAGEMENT STANDARDS

    Directory of Open Access Journals (Sweden)

    PALIEKHOVA L. L.

    2016-03-01

    Full Text Available Purpose. The purpose of the presented research is to explore the potential of international energy management standards to increase competitiveness of industrial enterprises under conditions of Ukrainian transitional economy. The study had the following objectives: to trace the evolution of fundamental energy efficiency standards; to discuss experience in their use in various countries; to identify factors that are key to achieving competitive advantage under the implementation ISO 50001. Methodology. This article presents a historical overview of the standardisation of principles and approaches for the purpose of the energy-efficient management. The research was carried out by studying the international documents, voluntary standards and national practices in the field of energy efficiency. Conclusions. The study examines the experiences of different countries in the field of energy management systems. The authors conducted a comparative analysis of the ISO 50001 with the other basic standards for the organisation of management. The system approach enables to identify the main factors and their impact on capacity to achieve competitive advantages, which are possible to obtain after certification to ISO 50001. Originality. The study reviewed and analysed the energy management penetration within its dynamics at time and country level. After analysing the statistical data and the results of the interviews, the authors identified 20 key factors affecting the competitiveness of enterprises that are certified to ISO 50001. All of these factors were divided into four groups, two groups represent external environment – opportunities and threats, and two groups – internal capacity – strengths and weaknesses of enterprises. Practical value. The proposed system of factors may be useful for the planning of actions towards strengthening the capacity of energy management systems in the context of the formation competitive advantages on the industrial

  2. Radioactive material package test standards and performance requirements - public perception

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Rawl, R.R.

    1992-01-01

    This paper addresses issues related to the public perception of the regulatory test standards and performance requirements for packaging and transporting radioactive material. Specifically, it addresses the adequacy of the package performance standards and testing for Type B packages, which are those packages designed for transporting the most hazardous quantities and forms of radioactive material. Type B packages are designed to withstand accident conditions in transport. To improve public perception, the public needs to better understand: (a) the regulatory standards and requirements themselves, (b) the extensive history underlying their development, and (c) the soundness of the technical foundation. The public needs to be fully informed on studies, tests, and analyses that have been carried out worldwide and form the basis of the regulatory standards and requirements. This paper provides specific information aimed at improving the public perception of packages test standards

  3. Energy performance of buildings—EPBD in Greece

    International Nuclear Information System (INIS)

    Dascalaki, E.G.; Balaras, C.A.; Gaglia, A.G.; Droutsa, K.G.; Kontoyiannidis, S.

    2012-01-01

    Transposition of the European Directive on the energy performance of buildings (EPBD) in Greece was enacted in 2008 by a national law. A follow-up regulation on the energy performance in the building sector—KENAK released in 2010, outlines the overall approach in accordance to European standards and EPBD mandates. All necessary technical specifications and detailed information for the implementation of KENAK are included in four new technical guidelines prepared in 2010, which are supported by an official national software. Issues related to the energy experts are handled by presidential decrees published in 2010; over 5400 temporary energy inspectors are already in place, while permanent accreditation is in progress. Energy performance design study of new buildings for obtaining a building permit is in place since October 2010 and issuing energy performance certificates as of January 2011. This paper presents an overview of the development and current EPBD stage of implementation in Greece, along with a first assessment of the lessons learned and experiences gained. - Highlights: ► EPBD transposition in Greece is a reality. ► KENAK is the main legislative instrument for improving building energy efficiency in Greece. ► Four new technical guidelines have been published to support KENAK. ► A national software was also prepared to support implementation of KENAK. ► Temporary accreditation of 5300 energy inspectors. ► Over 20,000 energy performance certificates issued in the first five months of implementation.

  4. 24 CFR 968.115 - Modernization and energy conservation standards.

    Science.gov (United States)

    2010-04-01

    ... changing or installing a new utility system, conduct a life-cycle cost analysis, reflecting installation... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Modernization and energy conservation standards. 968.115 Section 968.115 Housing and Urban Development Regulations Relating to Housing...

  5. Impacts of optimum cost effective energy efficiency standards

    International Nuclear Information System (INIS)

    Brancic, A.B.; Peters, J.S.; Arch, M.

    1991-01-01

    Building Codes are increasingly required to be responsive to social and economic policy concerns. In 1990 the State of Connecticut passes An Act Concerning Global Warming, Public Act 90-219, which mandates the revision of the state building code to require that buildings and building elements be designed to provide optimum cost-effective energy efficiency over the useful life of the building. Further, such revision must meet the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 90.1 - 1989. As the largest electric energy supplier in Connecticut, Northeast Utilities (NU) sponsored a pilot study of the cost effectiveness of alternative building code standards for commercial construction. This paper reports on this study which analyzed design and construction means, building elements, incremental construction costs, and energy savings to determine the optimum cost-effective building code standard. Findings are that ASHRAE 90.1 results in 21% energy savings and alternative standards above it result in significant additional savings. Benefit/cost analysis showed that both are cost effective

  6. Energy and indoor temperature consequences of adative thermal comfort standards

    NARCIS (Netherlands)

    Centnerova, L.; Hensen, J.L.M.

    2001-01-01

    The intent of the presented study was to quantify the implications for energy demand of indoor temperature requirements based on a proposed adaptive thermal comfort standard (7) relative to a more traditional thermal comfort approach. The study focuses on a typical office situation in a moderate

  7. Optimal Energy Mix with Renewable Portfolio Standards in Korea

    Directory of Open Access Journals (Sweden)

    Zong Woo Geem

    2016-05-01

    Full Text Available Korea is a heavily energy-dependent country whose primary energy consumption ranks ninth in the world. However, at the same time, it promised to reduce carbon emission and planned to use more renewable energy. Thus, the objective of this study is to propose an optimal energy mix planning model in electricity generation from various energy sources, such as gas, coal, nuclear, hydro, wind, photovoltaic, and biomass, which considers more renewable and sustainable portions by imposing governmental regulation named renewable portfolio standard (RPS. This optimization model minimizes various costs such as construction cost, operation and management cost, fuel cost, and carbon emission cost while satisfying minimal demand requirement, maximal annual installation potential, and renewable portfolio standard constraints. Results showed that this optimization model could successfully generate energy mix plan from 2012 to 2030 while minimizing the objective costs and satisfying all the constraints. Therefore, this optimization model contributes more efficient and objective method to the complex decision-making process with a sustainability option. This proposed energy mix model is expected to be applied not only to Korea, but also to many other countries in the future for more economical planning of their electricity generation while affecting climate change less.

  8. ASEAN-USAID buildings energy conservation project. Volume 1, Energy standards: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Levine, M.D.; Busch, J.F. [eds.][Lawrence Berkeley Lab., CA (United States); Deringer, J.J. [Deringer Group, Riva, MD (United States)

    1992-06-01

    Mandatory or voluntary energy-efficiency standards for new or existing buildings can play an important role in a national program aimed at promoting energy conservation. Building codes and standards can provide a degree of control over design and building practices throughout the construction process, and encourage awareness of energy-conscious design. Studies in developed countries indicate that efficiency standards can produce energy reductions on the order of 20 to 40% or more. Within ASEAN, analyses of the savings potential from the proposed standards suggest that if implemented, these standards would produce savings over current new design practice of 19% to 24%. In this volume we provide an overview of the ASEAN-USAID project aimed at promulgating standards for energy efficiency in commercial buildings. The process of developing and implementing energy-efficiency standards for buildings can be subdivided into two key components: policy development; and technical and economic analysis. Each of these involves a number of steps and processes, as outlined in Figure 1-1. This volume describes the technical and economic analyses used to develop the proposed energy efficiency standards for four countries (Malaysia, Thailand, the Philippines, and Indonesia), and to refine an energy standard existing in Singapore since 1979. Though oriented toward the ASEAN region, the analysis methods described here are applicable in a range of settings, provided appropriate modifications are made for local building construction, climatic, economic, and political conditions. Implementation issues are not specifically addressed here; rather this volume is oriented towards the analytical work needed to establish or revise an energy standard for buildings.

  9. 10 CFR 431.156 - Energy and water conservation standards and effective dates.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy and water conservation standards and effective dates. 431.156 Section 431.156 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM... Standards § 431.156 Energy and water conservation standards and effective dates. Each commercial clothes...

  10. Domestic and International Nuclear Energy Voluntary Consensus Standards Needs

    International Nuclear Information System (INIS)

    Hopper, Calvin Mitchell

    2013-01-01

    This report introduces the reader to the domestic and international standards development organizations (SDOs) and their structures and operations. It also identifies some of the support and subject matter needs for the development of standards on the subject of nuclear energy. The support needs are described with regard to organizational structure and subject-matter-expert (SME) participation that is required for producing voluntary consensus standards. The subject matter needs are described with regard to growing technologies and objectives that approach the boundaries of existing standards; implementation of knowledge; and safety of people, facilities, and the environment. Standards are proposed, developed, and produced by SMEs with the support of industry and government organizations. The voluntary consensus standards development process is, as its name implies, a voluntary effort. The problem in today's competitive market, impacted by global economic uncertainty, is that the voluntary participation is shifting from a collaborative industry and SME effort to a nearly SME-only one. This shift places a financial and/or time burden on the SMEs to the point that they are purposely withdrawing from the standards development process, both domestically and internationally. The standards development process desperately needs participation from more and younger SMEs. The report includes several suggestions on how this can be addressed.

  11. 75 FR 21981 - Energy Conservation Program: Energy Conservation Standards for Residential Water Heaters, Direct...

    Science.gov (United States)

    2010-04-27

    ... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EE-2006-BT-STD-0129] RIN 1904-AA90 Energy Conservation Program: Energy Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and Pool Heaters Correction In rule document 2010-7611 beginning on page 20112 in the issue of Friday...

  12. 76 FR 52852 - Energy Conservation Program: Energy Conservation Standards for Residential Clothes Dryers and...

    Science.gov (United States)

    2011-08-24

    ... INFORMATION CONTACT: Stephen L. Witkowski, U.S. Department of Energy, Office of Energy Efficiency and...-0121, (202) 586-7463, e-mail: stephen[email protected] . Ms. Elizabeth Kohl, U.S. Department of... paragraphs (b) and (h) to read as follows: Sec. 430.32 Energy and water conservation standards and their...

  13. Standard Terminology Relating to Photovoltaic Solar Energy Conversion

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This terminology pertains to photovoltaic (radiant-to-electrical energy conversion) device performance measurements and is not a comprehensive list of terminology for photovoltaics in general. 1.2 Additional terms used in this terminology and of interest to solar energy may be found in Terminology E 772.

  14. Maintaining a Viable Energy Savings Performance Contract

    National Research Council Canada - National Science Library

    Weber, Katherine L; Huckeby, Michael A

    2005-01-01

    Substantial amounts of information are available on Energy Savings Performance Contract award requirements, measurement, and verification, but we have found very little information on the day-to-day...

  15. Incorporating Non-energy Benefits into Energy Savings Performance Contracts

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Peter; Goldman, Charles; Gilligan, Donald; Singer, Terry

    2012-06-01

    This paper evaluates the issue of non-energy benefits within the context of the U.S. energy services company (ESCO) industry?a growing industry comprised of companies that provide energy savings and other benefits to customers through the use of performance-based contracting. Recent analysis has found that ESCO projects in the public/institutional sector, especially at K-12 schools, are using performance-based contracting, at the behest of the customers, to partially -- but not fully -- offset substantial accumulated deferred maintenance needs (e.g., asbestos removal, wiring) and measures that have very long paybacks (roof replacement). This trend is affecting the traditional economic measures policymakers use to evaluate success on a benefit to cost basis. Moreover, the value of non-energy benefits which can offset some or all of the cost of the non-energy measures -- including operations and maintenance (O&M) savings, avoided capital costs, and tradable pollution emissions allowances-- are not always incorporated into a formal cost-effectiveness analysis of ESCO projects. Nonenergy benefits are clearly important to customers, but state and federal laws that govern the acceptance of these types of benefits for ESCO projects vary widely (i.e., 0-100percent of allowable savings can come from one or more non-energy categories). Clear and consistent guidance on what types of savings are recognized in Energy Savings agreements under performance contracts is necessary, particularly where customers are searching for deep energy efficiency gains in the building sector.

  16. Architectural design and energy performance; Conception architecturale et performance energetique

    Energy Technology Data Exchange (ETDEWEB)

    Beaud, Ph. [Agence de l' Environnement et de la Maitrise de l' Energie, (ADEME), 06 - Valbonne (France); Pouget, A. [Bureau Etude Thermique, 75 - Paris (France); Sesolis, B. [TRIBU, 75 - Paris (France)] [and others

    2000-07-01

    This day was organized around the energy performance of the architecture in three parts. A first time dealt with the design of new buildings and private houses. Simulation tools for the energy optimization and practice of design are discussed. The second part was devoted to the new 2000 regulation with an open discussion on the regulatory costs. The last part forecasted the evolution until 2015 taking into account the french program of fight against the greenhouse effect, the limitation of the air conditioning consumption and the definition of a quality label concerning the energy performances. (A.L.B.)

  17. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  18. 24 CFR 902.43 - Management operations performance standards.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Management operations performance... URBAN DEVELOPMENT PUBLIC HOUSING ASSESSMENT SYSTEM PHAS Indicator #3: Management Operations § 902.43 Management operations performance standards. (a) Management operations sub-indicators. The following sub...

  19. Energy performance indicator report: fluid milk plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    In Canada, the dairy sector consumes significant amounts of energy and is looking for new ways of saving energy. The aim of this study, performed by the Competitive Analysis Centre Inc., was to find novel energy savings ideas for fluid milk plants. For this purpose, the energy consumption of 17 fluid milk plants, which accounts for over 50% of total Canadian output, was analyzed; first, at the plant level, and then by 8 categories at the sub-plant level in order to develop benchmarks that could be applied at both these levels. The paper provides background information on Canada's fluid milk sector and outlines the methodology used to develop and apply energy efficiency measures in the sector; the study findings are also presented. This report found that the energy consumption of the Canadian fluid milk sector could be lowered by applying the energy saving proposals developed herein.

  20. Performance Evaluation of Five Turbidity Sensors in Three Primary Standards

    Science.gov (United States)

    Snazelle, Teri T.

    2015-10-28

    Open-File Report 2015-1172 is temporarily unavailable.Five commercially available turbidity sensors were evaluated by the U.S. Geological Survey, Hydrologic Instrumentation Facility (HIF) for accuracy and precision in three types of turbidity standards; formazin, StablCal, and AMCO Clear (AMCO–AEPA). The U.S. Environmental Protection Agency (EPA) recognizes all three turbidity standards as primary standards, meaning they are acceptable for reporting purposes. The Forrest Technology Systems (FTS) DTS-12, the Hach SOLITAX sc, the Xylem EXO turbidity sensor, the Yellow Springs Instrument (YSI) 6136 turbidity sensor, and the Hydrolab Series 5 self-cleaning turbidity sensor were evaluated to determine if turbidity measurements in the three primary standards are comparable to each other, and to ascertain if the primary standards are truly interchangeable. A formazin 4000 nephelometric turbidity unit (NTU) stock was purchased and dilutions of 40, 100, 400, 800, and 1000 NTU were made fresh the day of testing. StablCal and AMCO Clear (for Hach 2100N) standards with corresponding concentrations were also purchased for the evaluation. Sensor performance was not evaluated in turbidity levels less than 40 NTU due to the unavailability of polymer-bead turbidity standards rated for general use. The percent error was calculated as the true (not absolute) difference between the measured turbidity and the standard value, divided by the standard value.The sensors that demonstrated the best overall performance in the evaluation were the Hach SOLITAX and the Hydrolab Series 5 turbidity sensor when the operating range (0.001–4000 NTU for the SOLITAX and 0.1–3000 NTU for the Hydrolab) was considered in addition to sensor accuracy and precision. The average percent error in the three standards was 3.80 percent for the SOLITAX and -4.46 percent for the Hydrolab. The DTS-12 also demonstrated good accuracy with an average percent error of 2.02 percent and a maximum relative standard

  1. A New Model to Simulate Energy Performance of VRF Systems

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Tianzhen; Pang, Xiufeng; Schetrit, Oren; Wang, Liping; Kasahara, Shinichi; Yura, Yoshinori; Hinokuma, Ryohei

    2014-03-30

    This paper presents a new model to simulate energy performance of variable refrigerant flow (VRF) systems in heat pump operation mode (either cooling or heating is provided but not simultaneously). The main improvement of the new model is the introduction of the evaporating and condensing temperature in the indoor and outdoor unit capacity modifier functions. The independent variables in the capacity modifier functions of the existing VRF model in EnergyPlus are mainly room wet-bulb temperature and outdoor dry-bulb temperature in cooling mode and room dry-bulb temperature and outdoor wet-bulb temperature in heating mode. The new approach allows compliance with different specifications of each indoor unit so that the modeling accuracy is improved. The new VRF model was implemented in a custom version of EnergyPlus 7.2. This paper first describes the algorithm for the new VRF model, which is then used to simulate the energy performance of a VRF system in a Prototype House in California that complies with the requirements of Title 24 ? the California Building Energy Efficiency Standards. The VRF system performance is then compared with three other types of HVAC systems: the Title 24-2005 Baseline system, the traditional High Efficiency system, and the EnergyStar Heat Pump system in three typical California climates: Sunnyvale, Pasadena and Fresno. Calculated energy savings from the VRF systems are significant. The HVAC site energy savings range from 51 to 85percent, while the TDV (Time Dependent Valuation) energy savings range from 31 to 66percent compared to the Title 24 Baseline Systems across the three climates. The largest energy savings are in Fresno climate followed by Sunnyvale and Pasadena. The paper discusses various characteristics of the VRF systems contributing to the energy savings. It should be noted that these savings are calculated using the Title 24 prototype House D under standard operating conditions. Actual performance of the VRF systems for real

  2. Thinking Globally: How ISO 50001 - Energy Management can make industrial energy efficiency standard practice

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee; Desai, Deann; Matteini, Marco; Meffert, William; Williams, Robert; Risser, Roland

    2009-08-01

    Industry utilizes very complex systems, consisting of equipment and their human interface, which are organized to meet the production needs of the business. Effective and sustainable energy efficiency programs in an industrial setting require a systems approach to optimize the integrated whole while meeting primary business requirements. Companies that treat energy as a manageable resource and integrate their energy program into their management practices have an organizational context to continually seek opportunities for optimizing their energy use. The purpose of an energy management system standard is to provide guidance for industrial and commercial facilities to integrate energy efficiency into their management practices, including fine-tuning production processes and improving the energy efficiency of industrial systems. The International Organization for Standardization (ISO) has identified energy management as one of its top five priorities for standards development. The new ISO 50001 will establish an international framework for industrial, commercial, or institutional facilities, or entire companies, to manage their energy, including procurement and use. This standard is expected to achieve major, long-term increases in energy efficiency (20percent or more) in industrial, commercial, and institutional facilities and to reduce greenhouse gas (GHG) emissions worldwide.This paper describes the impetus for the international standard, its purpose, scope and significance, and development progress to date. A comparative overview of existing energy management standards is provided, as well as a discussion of capacity-building needs for skilled individuals to assist organizations in adopting the standard. Finally, opportunities and challenges are presented for implementing ISO 50001 in emerging economies and developing countries.

  3. BUILDING DESIGN INFLUENCE ON THE ENERGY PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Moga Ligia

    2015-05-01

    Full Text Available Energy efficient design is a high priority in the national energy strategy of European countries considering the latest requirements of the European Directive on the Energy Performance of Buildings. The residential sector is responsible for a significant quantity of energy consumptions from the total amount of consumptions on a worldwide level. In residential building most of the energy consumptions are given mainly by heating, domestic hot water and lighting. Retrofitting the existing building stock offers great opportunities for reducing global energy consumptions and greenhouse gas emissions. The first part of the paper will address the need of thermal and energy retrofit of existing buildings. The second part will provide an overview on how various variables can influence the energy performance of a building that is placed in all four climatic zones from Romania. The paper is useful for specialist and designers from the construction field in understanding that buildings behave differently from the energy point of view in different climatic regions, even if the building characteristic remain the same.

  4. Energy efficient data sorting using standard sorting algorithms

    KAUST Repository

    Bunse, Christian; Hö pfner, Hagen; Roychoudhury, Suman; Mansour, Essam

    2011-01-01

    Protecting the environment by saving energy and thus reducing carbon dioxide emissions is one of todays hottest and most challenging topics. Although the perspective for reducing energy consumption, from ecological and business perspectives is clear, from a technological point of view, the realization especially for mobile systems still falls behind expectations. Novel strategies that allow (software) systems to dynamically adapt themselves at runtime can be effectively used to reduce energy consumption. This paper presents a case study that examines the impact of using an energy management component that dynamically selects and applies the "optimal" sorting algorithm, from an energy perspective, during multi-party mobile communication. Interestingly, the results indicate that algorithmic performance is not key and that dynamically switching algorithms at runtime does have a significant impact on energy consumption. © Springer-Verlag Berlin Heidelberg 2011.

  5. Ultra-high energy physics and standard basic principles

    Directory of Open Access Journals (Sweden)

    Gonzalez-Mestres Luis

    2014-04-01

    Full Text Available It has not yet been elucidated whether the observed flux suppression for ultra-high energy cosmic rays (UHECR at energies above ≃ 4 x 1019 eV is a signature of the Greisen-Zatsepin-Kuzmin (GZK cutoff or a consequence of other phenomena. In both cases, violations of the standard fundamental principles of Physics can be present and play a significant role. They can in particular modify cosmic-ray interactions, propagation or acceleration at very high energy. Thus, in a long-term program, UHECR data can hopefully be used to test relativity, quantum mechanics, energy and momentum conservation, vacuum properties... as well as the elementariness of standard particles. Data on cosmic rays at energies ≃ 1020 eV may also be sensitive to new physics generated well beyond Planck scale. A typical example is provided by the search for possible signatures of a Lorentz symmetry violation (LSV associated to a privileged local reference frame (the "vacuum rest frame", VRF. If a VRF exists, the internal structure of standard particles at ultra-high energy can undergo substantial modifications. Similarly, the conventional particle symmetries may cease to be valid at such energies instead of heading to a grand unification and the structure of vacuum may no longer be governed by standard quantum field theory. Then, the question whether the notion of Planck scale still makes sense clearly becomes relevant and the very grounds of Cosmology can undergo essential modifications. UHECR studies naturally interact with the interpretation of WMAP and Planck observations. Recent Planck data analyses tend to confirm the possible existence of a privileged space direction. If the observed phenomenon turns out to be a signature of the spinorial space-time (SST we suggested in 1996-97, then conventional Particle Physics may correspond to the local properties of standard matter at low enough energy and large enough distances. This would clearly strengthen the cosmological

  6. Factors Contributing to SMEs Failure in Meeting Supplier Performance Standards

    Directory of Open Access Journals (Sweden)

    van Scheers Louise

    2016-01-01

    Full Text Available This study sought to determine the factors that contribute to the failure of small and medium enterprises (SMEs in meeting supplier performance standards. Suppliers are faced with the challenge of SMEs failing to meet supplier performance standards because they rely on these providers of products and services, mainly SMEs, for their operations and to ultimately achieve their mandate. The researchers were able to establish the main factors contributing to SME failure in meeting supplier performance standards. These are as follows: unclear specifications and terms of references from suppliers; insufficient information provided to SME suppliers to ensure understanding of requirements; insufficient feedback and support; no support of SME suppliers based on their Black Economic Empowerment (BEE status; limited or no use of business support programs by SME suppliers; and external factors such as access to finance, changes in the economy, and location.

  7. International Standards to Develop and Promote Energy Efficiency and Renewable Energy Sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    International Standards are a powerful tool for disseminating new technologies and good practices, developing global markets and supporting the harmonization of government policies on energy efficiency and renewable sources on a global scale.

  8. Guidelines for Home Energy Upgrade Professionals: Standard Work Specifications for Multifamily Energy Upgrades (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2011-08-01

    This fact sheet provides essential information about the 2011 publication of the Workforce Guidelines for Multifamily Home Energy Upgrades, including their origin, their development with the help of industry leaders to create the standard work specifications for retrofit work.

  9. Automatic Energy Schemes for High Performance Applications

    Energy Technology Data Exchange (ETDEWEB)

    Sundriyal, Vaibhav [Iowa State Univ., Ames, IA (United States)

    2013-01-01

    Although high-performance computing traditionally focuses on the efficient execution of large-scale applications, both energy and power have become critical concerns when approaching exascale. Drastic increases in the power consumption of supercomputers affect significantly their operating costs and failure rates. In modern microprocessor architectures, equipped with dynamic voltage and frequency scaling (DVFS) and CPU clock modulation (throttling), the power consumption may be controlled in software. Additionally, network interconnect, such as Infiniband, may be exploited to maximize energy savings while the application performance loss and frequency switching overheads must be carefully balanced. This work first studies two important collective communication operations, all-to-all and allgather and proposes energy saving strategies on the per-call basis. Next, it targets point-to-point communications to group them into phases and apply frequency scaling to them to save energy by exploiting the architectural and communication stalls. Finally, it proposes an automatic runtime system which combines both collective and point-to-point communications into phases, and applies throttling to them apart from DVFS to maximize energy savings. The experimental results are presented for NAS parallel benchmark problems as well as for the realistic parallel electronic structure calculations performed by the widely used quantum chemistry package GAMESS. Close to the maximum energy savings were obtained with a substantially low performance loss on the given platform.

  10. Renewables portfolio standard and regional energy structure optimisation in China

    International Nuclear Information System (INIS)

    Fan, J.; Sun, W.; Ren, D.-M.

    2005-01-01

    Eastern Coastal areas of China have been developing rapidly since the implementation of reforms and the opening of China's economic markets in 1978. As in most areas of the world, this rapid economic growth has been accompanied by large increases in energy consumption. China's coal-dominated energy structure has resulted in serious ecological and environmental problems. Exploiting renewable energy resources and introducing Renewables Portfolio Standard (RPS) are some of the most important approaches towards optimising and sustaining the energy structure of China. This paper discusses international experiences in the implementation of RPS policies and prospects for using these policies to encourage renewable energy development in China, establishes a concise definition of renewable resources, differentiating between the broad definition (which includes hydro over 25 MW in size) from the narrow definition (which limits the eligibility of hydro to below 25 MW in size), and quantitatively analyses the potential renewable energy target. The research shows that: (1) Under the narrow hydro definition the renewable energy target would be 5.1% and under the broad hydro definition it would be 18.4%. (2) Western China has contributed 90.2% of the total renewable electricity generation in the country (if big and medium hydropowers are not included). Including big and medium hydropower, the figure is 63.8%. (3) Eastern electricity companies can achieve their quota by buying Tradable Renewable Energy Certificates (TRCs or Green Certificates) and by exploiting renewable energy resources in Western China. The successful implementation of the RPS policy will achieve the goal of sharing the benefits and responsibilities of energy production between the different regions of China

  11. Performance Measurement of Management System Standards Using the Balanced Scorecard

    Directory of Open Access Journals (Sweden)

    Jan Kopia

    2017-11-01

    Full Text Available Management system standards (MSS, such as ISO standards, TQM, etc. are widely-used standards adopted by millions of organizations worldwide. It is still an unclear question whether these standards are beneficial for an organization, besides the fact that they might be required or expected by law or customers. The question, whether MSS increase the efficiency, the output, or the performance of an organization is still discussed in scientific research. One reason might be that performance measurement itself is not fully understood or in constant development ranging from pure financial evaluations over intellectual capital rating to calculating of levels of environmental, social or economic expectations known as the Trible Bottom Line. The Balanced Scorecard is one possible solution for performance measurement on a strategic and operational level and therefore useful for the measurement of the influence of MSS within organizations. This study summarized current research in the field of performance measurement in the context of MSS and IMS and the use of BSC and quantitatively and qualitatively tests the usefulness of BSC in measuring the effect of MSSs using the Execution Premium. It was found that BSC is often used, that an average number of companies integrate their measurement initiatives of their MSSs into the BSC-process, and that a high integration of MSS into the BSC improves the organizational performance. This research is useful for researchers and practitioners in order to understand the benefits of the usage of the BSC in the context of MSS or Integrated Management Systems.

  12. Performance of an extrapolation chamber in computed tomography standard beams

    International Nuclear Information System (INIS)

    Castro, Maysa C.; Silva, Natália F.; Caldas, Linda V.E.

    2017-01-01

    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI. (author)

  13. Performance of an extrapolation chamber in computed tomography standard beams

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Maysa C.; Silva, Natália F.; Caldas, Linda V.E., E-mail: mcastro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI. (author)

  14. Performance profiles of major energy producers 1992

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-13

    Performance Profiles of Major Energy Producers 1992 is the sixteenth annual report of the Energy Information Administration`s (EIA) Financial Reporting System (FRS). The report examines financial and operating developments, with particular reference to the 25 major energy companies (the FRS companies) required to report annually on Form EIA-28. Financial information is reported by major lines of business, including oil and gas production, petroleum refining and marketing, and other energy operations. Domestic and international operations are examined separately in this report. The data are presented in the context of key energy market developments with a view toward identifying changing strategies of corporate development and measuring the apparent success of current ongoing operations.

  15. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    Ocean waves provide a sustainable, power-dense, predictable and widely available source of energy that could provide about 10 % of worlds energy needs. While research into waveenergy has been undertaken for decades, a significant increase in related activities has been seen in the recent years......, with more than 150 concepts currently being developed worldwide. Wave energy conversion concepts can be of many kinds, as the energy in the waves can be absorbed in many different ways. However, each concept is expected to require a thorough development process, involving different phases and prototypes....... Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. Thisimplicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development...

  16. A tool for standardized collector performance calculations including PVT

    DEFF Research Database (Denmark)

    Perers, Bengt; Kovacs, Peter; Olsson, Marcus

    2012-01-01

    A tool for standardized calculation of solar collector performance has been developed in cooperation between SP Technical Research Institute of Sweden, DTU Denmark and SERC Dalarna University. The tool is designed to calculate the annual performance of solar collectors at representative locations...... can be tested and modeled as a thermal collector, when the PV electric part is active with an MPP tracker in operation. The thermal collector parameters from this operation mode are used for the PVT calculations....

  17. Progress towards the specification of embodied energy performance criteria for New Zealand buildings

    Energy Technology Data Exchange (ETDEWEB)

    Baird, G.; Alcorn, A.; Wood, P.; Storey, J. B. [Victoria Univ., Wellington (New Zealand). School of Architecture; Jaques, R. [Building Research Association of New Zealand, Inc. (New Zealand)

    1998-11-01

    Incorporation of embodied energy performance criteria into New Zealand`s recently adopted performance-based building code is discussed. The paper also describes the concept of the Building Code and its energy related clauses and standards, work done to date to update the building materials` energy coefficients, and the progress made in using an embodied energy database. The purpose, desirability and likely pitfalls of such criteria, ways of specifying minimum performance, and relationships with operating energy criteria are also reviewed.

  18. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    . Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. This implicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development......, with more than 150 concepts currently being developed worldwide. Wave energy conversion concepts can be of many kinds, as the energy in the waves can be absorbed in many different ways. However, each concept is expected to require a thorough development process, involving different phases and prototypes...

  19. Developing an Energy Performance Modeling Startup Kit

    Energy Technology Data Exchange (ETDEWEB)

    Wood, A.

    2012-10-01

    In 2011, the NAHB Research Center began the first part of the multi-year effort by assessing the needs and motivations of residential remodelers regarding energy performance remodeling. The scope is multifaceted - all perspectives will be sought related to remodeling firms ranging in size from small-scale, sole proprietor to national. This will allow the Research Center to gain a deeper understanding of the remodeling and energy retrofit business and the needs of contractors when offering energy upgrade services. To determine the gaps and the motivation for energy performance remodeling, the NAHB Research Center conducted (1) an initial series of focus groups with remodelers at the 2011 International Builders' Show, (2) a second series of focus groups with remodelers at the NAHB Research Center in conjunction with the NAHB Spring Board meeting in DC, and (3) quantitative market research with remodelers based on the findings from the focus groups. The goal was threefold, to: Understand the current remodeling industry and the role of energy efficiency; Identify the gaps and barriers to adding energy efficiency into remodeling; and Quantify and prioritize the support needs of professional remodelers to increase sales and projects involving improving home energy efficiency. This report outlines all three of these tasks with remodelers.

  20. 77 FR 18477 - Energy Conservation Program: Energy Conservation Standards for Battery Chargers and External...

    Science.gov (United States)

    2012-03-27

    .... Summary of the Proposed Rule A. Benefits and Costs to Consumers B. Impact on Manufacturers C. National.... Discount Rates 12. Benefits From Effects of Standards on Energy Prices H. Consumer Subgroup Analysis I... Impact Analysis a. Significance of Energy Savings b. Net Present Value of Consumer Costs and Benefits c...

  1. 76 FR 43941 - Energy Conservation Program: Energy Conservation Standards for Direct Heating Equipment

    Science.gov (United States)

    2011-07-22

    ... included the HPBA membership directory, Air-Conditioning, Heating, and Refrigeration Institute (AHRI.... Summary of the Proposed Rule II. History of the Energy Conservation Standards Rulemaking and Current... notice. DOE's rationale is presented in further detail immediately below. II. History of the Energy...

  2. Energy Transformation: Teaching Youth about Energy Efficiency while Meeting Science Essential Standards

    Science.gov (United States)

    Kirby, Sarah D.; Chilcote, Amy G.

    2014-01-01

    This article describes the Energy Transformation 4-H school enrichment curriculum. The curriculum addresses energy efficiency and conservation while meeting sixth-grade science essential standards requirements. Through experiential learning, including building and testing a model home, youth learn the relationship between various technologies and…

  3. 6 CFR 27.230 - Risk-based performance standards.

    Science.gov (United States)

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Risk-based performance standards. 27.230 Section 27.230 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY CHEMICAL FACILITY... the facility and that discourages abuse through established disciplinary measures; (4) Deter, Detect...

  4. 20 CFR 404.1641 - Standards of performance.

    Science.gov (United States)

    2010-04-01

    ... appropriate Regional Commissioner after negotiation with each State agency. The intermediate goals are... considering the State agency to be substantially failing to comply with the performance standards. However... 404.1641 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY...

  5. 20 CFR 416.1041 - Standards of performance.

    Science.gov (United States)

    2010-04-01

    ... appropriate Regional Commissioner after negotiation with each State agency. The intermediate goals are... considering the State agency to be substantially failing to comply with the performance standards. However... 416.1041 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE AGED...

  6. 40 CFR 430.25 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... Soda Subcategory § 430.25 New source performance standards (NSPS). New sources subject to this subpart... fine papers are produced and soda facilities where pulp and paper are produced] Pollutant or pollutant... that does not use an exclusively TCF bleaching process, as disclosed by the discharger in its NPDES...

  7. Vocational and Technical Education Performance Standards and Competencies.

    Science.gov (United States)

    Connecticut State Board of Education, Hartford.

    These Connecticut vocational and technical performance standards and competencies are a guide for overall quality attainment in these seven vocational and technical program areas: agricultural science technology education; business and finance technology education; cooperative work education; family and consumer sciences education; marketing…

  8. 30 CFR 827.12 - Coal preparation plants: Performance standards.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal preparation plants: Performance standards...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.12 Coal preparation plants..., modification, reclamation, and removal activities at coal preparation plants shall comply with the following...

  9. Role of radiation standards in peaceful uses of nuclear energy

    International Nuclear Information System (INIS)

    Mahant, A.K.; Sathian, V.; Joseph, L.

    2009-01-01

    Radiation standards play an acute role in all the peaceful applications of nuclear energy, which is not limited to generation of electrical power anymore. Radioactive sources are being used in a very wide variety of applications, which can be broadly classified as medicine, agriculture, industry and scientific research. All these applications involve the use of radiation in a well-controlled manner and hence require accurate characterization and quantification of the radiation. Radiation Standards Section of Radiation Safety Systems Division at BARC is the apex national laboratory for all the radiological quantities related to various types of radiation sources. The laboratory develops, maintains and disseminates the standards to the users of the radiation sources all over the country and some of the neighbouring countries viz. Nepal, Bangladesh, Sri Lanka and Myanmar with an essential objective to bring homogeneity in all radiological measurements and make them compatible with the international standards. Various services provided by the Radiation Standards Section have been briefly described in the following sections. (author)

  10. Feasibility Study of Economics and Performance of Solar Photovoltaics at the Standard Chlorine of Delaware Superfund Site in Delaware City, Delaware. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

    Energy Technology Data Exchange (ETDEWEB)

    Salasovich, J.; Geiger, J.; Mosey, G.; Healey, V.

    2013-06-01

    The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Standard Chlorine of Delaware site in Delaware City, Delaware, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) provided technical assistance for this project. The purpose of this report is to assess the site for a possible photovoltaic (PV) system installation and estimate the cost, performance, and site impacts of different PV options. In addition, the report recommends financing options that could assist in the implementation of a PV system at the site.

  11. The Inter Facility Testing of a Standard Oscillating Water Column (OWC) Type Wave Energy Converter (WEC)

    DEFF Research Database (Denmark)

    Andersen, Morten Thøtt; Thomsen, Jonas Bjerg

    This report describes the behavior and preliminary performance of a simplified standard oscillating water column (OWC) wave energy converter (WEC). The same tests will be conducted at different scales at 6 different test facilities and the results obtained will be used for comparison. This project...

  12. Performance Analysis: Control of Hazardous Energy

    Energy Technology Data Exchange (ETDEWEB)

    De Grange, Connie E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Freeman, Jeff W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kerr, Christine E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-10-06

    LLNL experienced 26 occurrences related to the control of hazardous energy from January 1, 2008 through August 2010. These occurrences were 17% of the total number of reported occurrences during this 32-month period. The Performance Analysis and Reporting Section of the Contractor Assurance Office (CAO) routinely analyzes reported occurrences and issues looking for patterns that may indicate changes in LLNL’s performance and early indications of performance trends. It became apparent through these analyses that LLNL might have experienced a change in the control of hazardous energy and that these occurrences should be analyzed in more detail to determine if the perceived change in performance was real, whether that change is significant and if the causes of the occurrences are similar. This report documents the results of this more detailed analysis.

  13. 10 CFR 431.446 - Small electric motors energy conservation standards and their effective dates. [Reserved

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Small electric motors energy conservation standards and... CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Small Electric Motors Energy Conservation Standards § 431.446 Small electric motors energy conservation standards and their...

  14. Variability of consumer impacts from energy efficiency standards

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, James E.; Liu, Xiaomin

    2000-06-15

    A typical prospective analysis of the expected impact of energy efficiency standards on consumers is based on average economic conditions (e.g., energy price) and operating characteristics. In fact, different consumers face different economic conditions and exhibit different behaviors when using an appliance. A method has been developed to characterize the variability among individual households and to calculate the life-cycle cost of appliances taking into account those differences. Using survey data, this method is applied to a distribution of consumers representing the U.S. Examples of clothes washer standards are shown for which 70-90% of the population benefit, compared to 10-30% who are expected to bear increased costs due to new standards. In some cases, sufficient data exist to distinguish among demographic subgroups (for example, low income or elderly households) who are impacted differently from the general population. Rank order correlations between the sampled input distributions and the sampled output distributions are calculated to determine which variability inputs are main factors. This ''importance analysis'' identifies the key drivers contributing to the range of results. Conversely, the importance analysis identifies variables that, while uncertain, make so little difference as to be irrelevant in deciding a particular policy. Examples will be given from analysis of water heaters to illustrate the dominance of the policy implications by a few key variables.

  15. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1982-02-01

    The way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method has nothing in common with the use of a camera in clinical practice. Particularly in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. The IEC document 'Characteristics and test conditions of radionuclide imaging devices' is discussed

  16. Energy sustainability performance of the regional economy

    Directory of Open Access Journals (Sweden)

    N. I. Danilov

    2005-03-01

    Full Text Available The results of the study of the dynamics of energy intensity of gross regional product of the Sverdlovsk region for the period 1996 - 2003 years. and projections for the period up to 2015. The principal possibility of growth performance of the regional economy, without a significant increase in the consumption of primary fuel.

  17. Cost optimal levels for energy performance requirements

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Aggerholm, Søren; Kluttig-Erhorn, Heike

    This report summarises the work done within the Concerted Action EPBD from December 2010 to April 2011 in order to feed into the European Commission's proposal for a common European procedure for a Cost-Optimal methodology under the Directive on the Energy Performance of Buildings (recast) 2010/3...

  18. Raising the energy performance of historical dwellings

    NARCIS (Netherlands)

    van Krugten, L.T.F.; Hermans, L.M.C.; Havinga, L.C.; Pereira Roders, A.R.; Schellen, H.L.

    2016-01-01

    Purpose: Earlier studies assume that historical dwellings and post-war dwellings in particular, are less sustainable than modern dwellings, justifying its demolition. Over time, historical buildings have been transformed and their energy performance improved. However, there is little known on the

  19. Assessment of the Japanese Energy Efficiency Standards Program

    Directory of Open Access Journals (Sweden)

    Jun Arakawa

    2015-03-01

    Full Text Available Japanese energy efficiency standards program for appliances is a unique program which sets and revises mandatory standards based on the products of the highest energy efficiency on the markets. This study assessed the cost-effectiveness of the standard settings for air conditioner as a major residential appliance or typical example in the program. Based on analyses of empirical data, the net costs and effects from 1999 to 2040 were estimated. When applying a discount rate of 3%, the cost of abating CO2 emissions realized through the considered standards was estimated to be -13700 JPY/t-CO2. The sensitivity analysis, however, showed the cost turns into positive at a discount rate of 26% or higher. The authors also revealed that the standards’ “excellent” cost-effectiveness largely depends on that of the 1st standard setting, and the CO2 abatement cost through the 2nd standard was estimated to be as high as 26800 JPY/t-CO2. The results imply that the government is required to be careful about the possible economic burden imposed when considering introducing new, additional standards.

  20. DEMONSTRATION OF THE DOE INTERIM ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL RESIDENTIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, A. D.; Baechler, H. C.; Di Massa, F. V.; Lucas, R. G.; Shankle, D. L.

    1992-01-01

    In accordance with federal legislation, the U.S. Department of Energy (DOE) has sponsored a study to demonstrate use of its Interim Energy Conservation Standards for New Federal Residential Buildings. The demonstration study was conducted by DOE and the Pacific Northwest Laboratory (PNL). The demonstration is the second step in a three-step process: I) development of interim standards, 2) demonstration of the interim standards, and 3) development of final standards. The standards are mandatory for federal agency housing procurements. Nevertheless, PNL found at the start of the demonstration that agency use of the interim standards had been minimal. The purpose of the standards is to improve the energy efficiency of federal housing and increase the use of nondepletable energy sources. In accordance with the legislation, the standards were to be performance-based rather than prescribing specific energy conservation measures. To fulfill this aspect of the legislation, the standards use a computer software program called COSTSAFR which generates a point system that individualizes the standards to specific projects based on climate, housing type, and fuel costs. The standards generate minimum energy-efficiency requirements by applying the life-cycle cost methodology developed for federal projects. For the demonstration, PNL and DOE chose five federal agency housing projects which had been built in diverse geographic and climate regions. Participating agencies were the Air Force, the Army (which provided two case studies), the Navy, and the Department of Health and Human Services. PNL worked with agency housing procurement officials and designers/architects to hypothetically apply the interim standards to the procurement and design of each housing project. The demonstration started at the point in the project where agencies would establish their energyefficiency requirements for the project and followed the procurement process through the designers' use of the point

  1. Monte Carlo calculations for intermediate-energy standard neutron field

    International Nuclear Information System (INIS)

    Joneja, O.P.; Subbukutty, K.; Iyengar, S.B.D.; Navalkar, M.P.

    Intermediate-Energy Standard Neutron Field (ISNF) which produces a well characterised spectrum in the energy range of interest for fast reactors including breeders, has been set up at NBS using thin enriched 235 U fission sources. A proposal has been made for setting up a similar facility at BARC using however, easily available natural U instead of enriched U sources, to start with. In order to simulate the neutronics of such a facility Monte Carlo method of calculations has been adopted and developed. The results of these calculations have been compared with those of NBS and it is found that there may be a maximum difference of 10% in spectrum characteristics for the two cases of using thick and thin fission sources. (K.B.)

  2. Performance of deep geothermal energy systems

    Science.gov (United States)

    Manikonda, Nikhil

    Geothermal energy is an important source of clean and renewable energy. This project deals with the study of deep geothermal power plants for the generation of electricity. The design involves the extraction of heat from the Earth and its conversion into electricity. This is performed by allowing fluid deep into the Earth where it gets heated due to the surrounding rock. The fluid gets vaporized and returns to the surface in a heat pipe. Finally, the energy of the fluid is converted into electricity using turbine or organic rankine cycle (ORC). The main feature of the system is the employment of side channels to increase the amount of thermal energy extracted. A finite difference computer model is developed to solve the heat transport equation. The numerical model was employed to evaluate the performance of the design. The major goal was to optimize the output power as a function of parameters such as thermal diffusivity of the rock, depth of the main well, number and length of lateral channels. The sustainable lifetime of the system for a target output power of 2 MW has been calculated for deep geothermal systems with drilling depths of 8000 and 10000 meters, and a financial analysis has been performed to evaluate the economic feasibility of the system for a practical range of geothermal parameters. Results show promising an outlook for deep geothermal systems for practical applications.

  3. Flavor democracy in standard models at high energies

    International Nuclear Information System (INIS)

    Cvetic, G.; Kim, C.S.

    1993-01-01

    It is possible that the standard model (SM) is replaced around some transition energy Λ by a new, possibly Higgsless, 'flavor gauge theory' such that the Yukawa (running) parameters of SM at E∼Λ show up an (approximate) flavor democracy (FD). We investigate the latter possibility by studying the renormalization group equations for the Yukawa couplings of SM with one and two Higgs doublets, by evolving them from given physical values at low energies (E≅1 GeV) to Λ (∼Λ pole ) and comparing the resulting fermion masses and CKM matrix elements at E≅Λ for various m t phy and ratios y u /y d of vacuum expectation values. We find that the minimal SM and the closely related SM with two Higgs doublets (type I) show increasing deviation from FD when energy is increased, but that SM with two Higgs doublets (type II) clearly tends to FD with increasing energy - in both the quark and the leptonic sector (q-q and l-l FD). Furthermore, we find within the type-II model that, for Λ pole Planck , m t phy can be less than 200 GeV in most cases of chosen y u /y d . Under the assumption that also the corresponding Yukawa couplings in the quark and the leptonic sector at E≅Λ are equal (l-q FD), we derive estimates of bounds on masses of top quark and tau-neutrino, which are compatible with experimental bounds. (orig.)

  4. Using SWE Standards for Ubiquitous Environmental Sensing: A Performance Analysis

    Directory of Open Access Journals (Sweden)

    Joaquín Huerta

    2012-08-01

    Full Text Available Although smartphone applications represent the most typical data consumer tool from the citizen perspective in environmental applications, they can also be used for in-situ data collection and production in varied scenarios, such as geological sciences and biodiversity. The use of standard protocols, such as SWE, to exchange information between smartphones and sensor infrastructures brings benefits such as interoperability and scalability, but their reliance on XML is a potential problem when large volumes of data are transferred, due to limited bandwidth and processing capabilities on mobile phones. In this article we present a performance analysis about the use of SWE standards in smartphone applications to consume and produce environmental sensor data, analysing to what extent the performance problems related to XML can be alleviated by using alternative uncompressed and compressed formats.

  5. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009....../10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test....

  6. Performance evaluation of emerging JPEGXR compression standard for medical images

    International Nuclear Information System (INIS)

    Basit, M.A.

    2012-01-01

    Medical images require loss less compression as a small error due to lossy compression may be considered as a diagnostic error. JPEG XR is the latest image compression standard designed for variety of applications and has a support for lossy and loss less modes. This paper provides in-depth performance evaluation of latest JPEGXR with existing image coding standards for medical images using loss less compression. Various medical images are used for evaluation and ten images of each organ are tested. Performance of JPEGXR is compared with JPEG2000 and JPEGLS using mean square error, peak signal to noise ratio, mean absolute error and structural similarity index. JPEGXR shows improvement of 20.73 dB and 5.98 dB over JPEGLS and JPEG2000 respectively for various test images used in experimentation. (author)

  7. Standards of performance and aesthetics in counselling and beyond

    DEFF Research Database (Denmark)

    Nissen, Morten

    2016-01-01

    The article discusses performance standards in relation to Danish experiments with expanding drug counselling into ‘aesthetic documentation’ which is a hybrid of art with narrative practice. This relation is problematic, since the instrumental use defies the point in art, and since ‘aesthetic...... subjectivity. Then five claims are made about ‘aesthetic documentation’ as an alternative: The art works can be seen as prototypes rather than rigid standardizations; they represent collaboration rather than individualized performance; they work as staging or display in close connection with the substantial...... meaning of activities and their products; they objectify and thus achieve social recognition of clients and professionals; as art, they open to flexible, diverse and transforming attributions of meaning and value; and they address social problems rather than individualized malfunctions. In conclusion...

  8. HEP graphics: Standards and portability versus performance and cost

    International Nuclear Information System (INIS)

    Myers, D.R.

    1989-01-01

    After mentioning the range of applications for which computer graphics is used in high energy physics, some of the characteristics required of graphics hardware are presented, along with a discussion of how well these requirements are likely to be met by the computer industry. Moving on to the topic of software, the status of the more important graphics standards is covered briefly, as well as their evolution in the medium term. The point will be made that HEP, perhaps even more than other areas, has conflicting requirements for graphics systems. The subject is manpower-intensive, and the physics community has to made a trade-off. (orig.)

  9. An aggregated energy security performance indicator

    International Nuclear Information System (INIS)

    Martchamadol, Jutamanee; Kumar, S.

    2013-01-01

    Highlights: ► AESPI shows a country’s (or province’s) energy security status. ► AESPI considers social, economic and environmental aspects using 25 indicators. ► AESPI shows the impact of the trend of energy policies/measures. ► AESPI could be a tool for monitoring and evaluating the impact of energy policies. -- Abstract: An “Aggregated Energy Security Performance Indicator (AESPI)” has been developed by considering 25 individual indicators representing social, economy and environmental dimensions. The principle used, data required and the methodology for the development of AESPI have been detailed. AESPI requires time series data for its development and its value ranges from 0 to 10. The characteristics of AESPI have been compared with the existing indicators in terms of methodology, data requirements, analysis possible and the applications. The advantages of AESPI is that it not only assists in knowing the past energy security status of a country, but also helps in assessing the future status considering the energy policies and plans of the country, thus enabling the monitoring of the impacts of the policies.

  10. UK key performance indicators and quality assurance standards for colonoscopy.

    Science.gov (United States)

    Rees, Colin J; Thomas Gibson, Siwan; Rutter, Matt D; Baragwanath, Phil; Pullan, Rupert; Feeney, Mark; Haslam, Neil

    2016-12-01

    Colonoscopy should be delivered by endoscopists performing high quality procedures. The British Society of Gastroenterology, the UK Joint Advisory Group on GI Endoscopy, and the Association of Coloproctology of Great Britain and Ireland have developed quality assurance measures and key performance indicators for the delivery of colonoscopy within the UK. This document sets minimal standards for delivery of procedures along with aspirational targets that all endoscopists should aim for. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Self-assessment: Strategy for higher standards, consistency, and performance

    International Nuclear Information System (INIS)

    Ide, W.E.

    1996-01-01

    In late 1994, Palo Verde operations underwent a transformation from a unitized structure to a single functional unit. It was necessary to build consistency in watchstanding practices and create a shared mission. Because there was a lack of focus on actual plant operations and because personnel were deeply involved with administrative tasks, command and control of evolutions were weak. Improvement was needed. Consistent performance standards have been set for all three operating units. These expectation focus on nuclear, radiological, and industrial safety. Straightforward descriptions of watchstanding and monitoring practices have been provided to all department personnel. The desired professional and leadership qualities for employee conduct have been defined and communicated thoroughly. A healthy and competitive atmosphere developed with the successful implementation of these standards. Overall performance improved. The auxiliary operators demonstrated increased pride and ownership in the performance of their work activities. In addition, their morale improved. Crew teamwork improved as well as the quality of shift briefs. There was a decrease in the noise level and the administrative functions in the control room. The use of self-assessment helped to anchor and define higher and more consistent standards. The proof of Palo Verde's success was evident when an Institute of Nuclear Power Operations finding was turned into a strength within 1 yr

  12. Predicting energy performance of a net-zero energy building: A statistical approach

    International Nuclear Information System (INIS)

    Kneifel, Joshua; Webb, David

    2016-01-01

    Highlights: • A regression model is applied to actual energy data from a net-zero energy building. • The model is validated through a rigorous statistical analysis. • Comparisons are made between model predictions and those of a physics-based model. • The model is a viable baseline for evaluating future models from the energy data. - Abstract: Performance-based building requirements have become more prevalent because it gives freedom in building design while still maintaining or exceeding the energy performance required by prescriptive-based requirements. In order to determine if building designs reach target energy efficiency improvements, it is necessary to estimate the energy performance of a building using predictive models and different weather conditions. Physics-based whole building energy simulation modeling is the most common approach. However, these physics-based models include underlying assumptions and require significant amounts of information in order to specify the input parameter values. An alternative approach to test the performance of a building is to develop a statistically derived predictive regression model using post-occupancy data that can accurately predict energy consumption and production based on a few common weather-based factors, thus requiring less information than simulation models. A regression model based on measured data should be able to predict energy performance of a building for a given day as long as the weather conditions are similar to those during the data collection time frame. This article uses data from the National Institute of Standards and Technology (NIST) Net-Zero Energy Residential Test Facility (NZERTF) to develop and validate a regression model to predict the energy performance of the NZERTF using two weather variables aggregated to the daily level, applies the model to estimate the energy performance of hypothetical NZERTFs located in different cities in the Mixed-Humid Climate Zone, and compares these

  13. Daylight and energy implications for CIE standard skies

    International Nuclear Information System (INIS)

    Li, Danny H.W.

    2007-01-01

    Recently, the International Commission on Illumination (CIE) has adopted a range of 15 standard skies, which include the existing CIE overcast, very clear and cloudless polluted skies, covering the whole probable spectrum of usual skies found in the world. The traditional daylight factor (DF) approach with the calculations being based on an isotropic overcast sky, however, cannot cater to the dynamic variations in daylight luminance and illuminance as the sun's position changes under non-overcast skies. Currently, we propose a numerical procedure that considers the changes in the luminance of sky elements to predict the interior daylight illuminance under the 15 CIE standard skies. This paper evaluates the method by using a typical room with a large vertical glazing window facing north. The available daylight for the room at mean hourly sun positions in each month in terms of DF and illuminance levels were determined and compared with those based on a computer program, namely, RADIANCE. A modification to the ground reflected component was made when a well defined shadow was cast in front of the window facade. It is shown that the results estimated by the proposed approach are in reasonably good agreement with those produced from RADIANCE. The interior daylight and lighting energy consumption were also determined using the proposed and the traditional DF approaches. The findings reveal that daylighting designs using existing CIE overcast sky only would considerably underestimate the indoor daylight availability and electric lighting energy savings, especially under high design indoor illuminance settings

  14. Specification of Energy Assessment Methodologies to Satisfy ISO 50001 Energy Management Standard

    Science.gov (United States)

    Kanneganti, Harish

    Energy management has become more crucial for industrial sector as a way to lower their cost of production and in reducing their carbon footprint. Environmental regulations also force the industrial sector to increase the efficiency of their energy usage. Hence industrial sector started relying on energy management consultancies for improvements in energy efficiency. With the development of ISO 50001 standard, the entire energy management took a new dimension involving top level management and getting their commitment on energy efficiency. One of the key requirements of ISO 50001 is to demonstrate continual improvement in their (industry) energy efficiency. The major aim of this work is to develop an energy assessment methodology and reporting format to tailor the needs of ISO 50001. The developed methodology integrates the energy reduction aspect of an energy assessment with the requirements of sections 4.4.3 (Energy Review) to 4.4.6 (Objectives, Targets and Action Plans) in ISO 50001 and thus helping the facilities in easy implementation of ISO 50001.

  15. 40 CFR 427.35 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Starch Binder) Subcategory § 427.35 Standards of performance for new sources. The following standards of...

  16. 40 CFR 427.45 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Elastomeric Binder) Subcategory § 427.45 Standards of performance for new sources. The following standards of...

  17. Energy management system based on standard 50001 in the company Feed Cienfuegos

    International Nuclear Information System (INIS)

    Monteagudo Yanes, José P.; Crespo Sánchez, Gustavo; Montesino Pérez, Milagros; Cruz Virosa, Ibis; Cabrera Sánchez, Jorge Luis

    2017-01-01

    The energy management in manufacturing of balanced feed requires the Company Feed Cienfuegos to have systems and processes that enable efficiency and quality in production, improve energy performance and increase their competitiveness. Technology of Total Efficient Energy Management (TTEEM) and Cuban Standard ISO 50001 that are promoted and researched by the Center for Studies of Energy and Environment (CEEMA), of the University of Cienfuegos and the necessity and possibility of this Company to improve energy management allowed undertaking this project. Getting and use of energy performance indicator against production and the energy base line for daily control of energy consumption allowed decreasing from 12.8 kWh/t on average, to values below 10 kWh/t for the same production levels (500t/day). This result represents the reduction of energy consumption in the order of 364,000 kWh/year and consequently 15% of the energy item costs. This result is equivalent in cost of generation to 120 tons of oil/year, which at current oil prices mean a savings of $ 6,000 USD/year. (author)

  18. Empirical Study on Annual Energy-Saving Performance of Energy Performance Contracting in China

    Directory of Open Access Journals (Sweden)

    Hongquan Ruan

    2018-05-01

    Full Text Available A lack of trust in Energy Service Company (ESCo is the most critical factor affecting the development of Energy Performance Contracting (EPC in China, compared with other constraints. One cannot easily estimate the energy-saving performance of an EPC project. Under that condition, lack of trust may cause the Energy-Consuming Unit (ECU to suspect the energy-saving performance promised by the ESCo, thus leaving potentially profitable projects without necessary funding. Currently, specific studies taking an across-projects viewpoint on annual energy-saving performance of EPC projects in multiple subsectors, objectively and quantitatively, are lacking. This paper studies the regression relationships of annual energy-saving quantity in terms of revamping cost and the regression relationships of annual cost saving in terms of revamping cost. The regression results show that there are statistically significant correlations in the above relationships in the nine subsectors investigated. This is significant for ESCos and ECUs, because knowledge on energy-saving performance could contribute to EPC investment decisions and trust relationships between ESCos and ECUs. Then, a multiple linear regression model of revamping cost is set up to analyze its influencing factors. The model indicates that the subsector the sample belongs to, financing, registered capital of the ESCo, and contract period have significant effects on revamping cost. Thus, policy implications regarding innovation of EE promotion technology, clarifying ESCos’ exit mechanism, innovation of financing mechanism, and improving the market credit environment for promoting investment in EPC projects, are provided.

  19. Performance Limits of Communication with Energy Harvesting

    KAUST Repository

    Znaidi, Mohamed Ridha

    2016-04-01

    In energy harvesting communications, the transmitters have to adapt transmission to the availability of energy harvested during communication. The performance of the transmission depends on the channel conditions which vary randomly due to mobility and environmental changes. During this work, we consider the problem of power allocation taking into account the energy arrivals over time and the quality of channel state information (CSI) available at the transmitter, in order to maximize the throughput. Differently from previous work, the CSI at the transmitter is not perfect and may include estimation errors. We solve this problem with respect to the energy harvesting constraints. Assuming a perfect knowledge of the CSI at the receiver, we determine the optimal power policy for different models of the energy arrival process (offline and online model). Indeed, we obtain the power allocation scheme when the transmitter has either perfect CSI or no CSI. We also investigate of utmost interest the case of fading channels with imperfect CSI. Moreover, a study of the asymptotic behavior of the communication system is proposed. Specifically, we analyze of the average throughput in a system where the average recharge rate goes asymptotically to zero and when it is very high.

  20. State Energy Efficiency Resource Standards: Design, Status, and Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Steinberg, D.; Zinaman, O.

    2014-05-01

    An energy efficiency resource standard (EERS) is a policy that requires utilities or other entities to achieve a specified amount of energy savings through customer energy efficiency programs within a specified timeframe. EERSs may apply to electricity usage, natural gas usage, or both. This paper provides an overview of the key design features of EERSs for electricity, reviews the variation in design of EERSs across states, and provides an estimate of the amount of savings required by currently specified EERSs in each state. As of December, 2013, 23 states have active and binding EERSs for electricity. We estimate that state EERSs will require annual electricity savings of approximately 8-11% of total projected demand by 2020 in states with EERSs, however the level of savings targeted by the policies varies significantly across states. In addition to the variation in targeted savings, the design of EERSs varies significantly across states leading to differences in the suite of incentives created by the policy, the flexibility of compliance with the policy, the balance of benefits and costs of the policy between producers and consumers, and the certainty with which the policy will drive long-term savings.

  1. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  2. Regional cooperation in energy efficiency standard-setting and labeling in North America

    Energy Technology Data Exchange (ETDEWEB)

    Wiel, Stephen; Van Wie McGrory, Laura

    2003-08-04

    The North American Energy Working Group (NAEWG) was established in 2001 by the governments of Canada, Mexico, and the United States. The goals of NAEWG are to foster communication and cooperation on energy-related matters of common interest, and to enhance North American energy trade and interconnections consistent with the goal of sustainable development, for the benefit of all three countries. At its outset, NAEWG established teams to address different aspects of the energy sector. One, the Energy Efficiency Expert Group, undertook activity in three areas: (1) analyzing commonalities and differences in the test procedures of Canada, Mexico, and the United States, and identifying specific products for which the three countries might consider harmonization; (2) exploring possibilities for increased mutual recognition of laboratory test results; and (3) looking at possibilities for enhanced cooperation in the Energy Star voluntary endorsement labeling program. To support NAEWG's Expert Group on Energy Efficiency (NAEWG-EE), USDOE commissioned Lawrence Berkeley National Laboratory, representing the Collaborative Labeling and Appliance Standards Program (CLASP), to prepare a resource document comparing current standards, labels, and test procedure regulations in Canada, Mexico, and the United States. The resulting document identified 46 energy-using products for which at least one of the three countries has energy efficiency regulations. Three products--refrigerators/freezers, room air conditioners, and integral horsepower three-phase electric motors--have identical minimum energy performance standards (MEPS) and test procedures in the three countries. Ten other products have different MEPS and test procedures, but have the near-term potential for harmonization. NAEWG-EE is currently working to identify mechanisms for mutual recognition of test results. With consultative support from the United States and Canada through NAEWG-EE, Mexico is exploring possibilities

  3. DOE standard: The Department of Energy Laboratory Accreditation Program for radiobioassay

    International Nuclear Information System (INIS)

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP) for Radiobioassay, for use by the US Department of Energy (DOE) and DOE Contractor radiobioassay programs. This standard is intended to be used in conjunction with the general administrative technical standard that describes the overall DOELAP accreditation process--DOE-STD-1111-98, Department of Energy Laboratory Accreditation Program Administration. This technical standard pertains to radiobioassay service laboratories that provide either direct or indirect (in vivo or in vitro) radiobioassay measurements in support of internal dosimetry programs at DOE facilities or for DOE and DOE contractors. Similar technical standards have been developed for other DOELAP dosimetry programs. This program consists of providing an accreditation to DOE radiobioassay programs based on successful completion of a performance-testing process and an on-site evaluation by technical experts. This standard describes the technical requirements and processes specific to the DOELAP Radiobioassay Accreditation Program as required by 10 CFR 835 and as specified generically in DOE-STD-1111-98

  4. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  5. Energy-efficiency labels and standards: A guidebook for appliances, equipment and lighting

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, James E.; Wiel, Stephen

    2001-02-16

    Energy-performance improvements in consumer products are an essential element in any government's portfolio of energy-efficiency and climate change mitigation programs. Governments need to develop balanced programs, both voluntary and regulatory, that remove cost-ineffective, energy-wasting products from the marketplace and stimulate the development of cost-effective, energy-efficient technology. Energy-efficiency labels and standards for appliances, equipment, and lighting products deserve to be among the first policy tools considered by a country's energy policy makers. The U.S. Agency for International Development (USAID) and the United Nations Foundation (UNF) recognize the need to support policy makers in their efforts to implement energy-efficiency standards and labeling programs and have developed this guidebook, together with the Collaborative Labeling and Appliance Standards Program (CLASP), as a primary reference. This guidebook was prepared over the course of the past year with significant contribution from the authors and reviewers mentioned previously. Their diligent participation has made this the international guidance tool it was intended to be. The lead authors would also like to thank the following individuals for their support in the development, production, and distribution of the guidebook: Marcy Beck, Elisa Derby, Diana Dhunke, Ted Gartner, and Julie Osborn of Lawrence Berkeley National Laboratory as well as Anthony Ma of Bevilacqua-Knight, Inc. This guidebook is designed as a manual for government officials and others around the world responsible for developing, implementing, enforcing, monitoring, and maintaining labeling and standards-setting programs. It discusses the pros and cons of adopting energy-efficiency labels and standards and describes the data, facilities, and institutional and human resources needed for these programs. It provides guidance on the design, development, implementation, maintenance, and evaluation of the

  6. 76 FR 70547 - Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts

    Science.gov (United States)

    2011-11-14

    ... the term ``fluorescent lamp,'' which EPCA defines as ``a low pressure mercury electric-discharge... discharge into light,'' and as including the four enumerated types of fluorescent lamps for which EPCA... Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts; Final Rule #0;#0;Federal...

  7. 78 FR 77019 - Energy Conservation Program: Energy Conservation Standards for Certain Consumer Products

    Science.gov (United States)

    2013-12-20

    ... air conditioning heat pump'' that were established in section 5 of the American Energy Manufacturing... heat pump'' product class, including the definition and standards. DATES: DOE will accept comments....gov . Table of Contents I. Background and Authority II. Discussion III. Procedural Requirements A...

  8. 78 FR 25626 - Energy Conservation Program for Consumer Products: Energy Conservation Standards for Ceiling Fans...

    Science.gov (United States)

    2013-05-02

    ... Conservation Program for Consumer Products: Energy Conservation Standards for Ceiling Fans and Ceiling Fan... for residential ceiling fans and ceiling fan light kits in the Federal Register. This document... other aspect of the rulemaking for ceiling fans and ceiling fan light kits. The comment period is...

  9. 75 FR 59469 - Energy Conservation Program: Energy Conservation Standards for Residential Refrigerators...

    Science.gov (United States)

    2010-09-27

    .... Methodology and Discussion A. Market and Technology Assessment 1. Exclusion of Wine Coolers From This.... Benefits From Effects of Standards on Energy Prices H. Consumer Subgroup Analysis I. Manufacturer Impact.... Net Present Value of Consumer Costs and Benefits c. Indirect Impacts on Employment 4. Impact on...

  10. Multiphoton production at high energies in the standard model. II

    International Nuclear Information System (INIS)

    Mahlon, G.

    1993-01-01

    We examine multiphoton production in the electroweak sector of the standard model in the high-energy limit using the equivalence theorem in combination with spinor helicity techniques. We utilize currents consisting of a charged scalar, spinor, or vector line that radiates n photons. Only one end of the charged line is off shell in these currents, which are known for the cases of like-helicity and one unlike-helicity photons. We obtain a wide variety of helicity amplitudes for processes involving two pairs of charged particles by considering combinations of four currents. We examine the situation with respect to currents which have both ends of the charged line off shell, and present solutions for the case of like-helicity photons. These new currents may be combined with two of the original currents to produce additional amplitudes involving Higgs bosons, longitudinal Z, or neutrino pairs

  11. Trendy solutions: Why do states adopt Sustainable Energy Portfolio Standards?

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, Jess [Georgia Institute of Technology, 685 Cherry Street, Atlanta, GA 30332-0345 (United States)], E-mail: jess.chandler@gatech.edu

    2009-08-15

    Thirty-four states had adopted Sustainable Energy Portfolio Standards (SEPS) or similar goals by the end of 2008, with 14 adoptions since 2006. There appears to be something trendy about SEPS and states may adopt SEPS when internal variables would indicate otherwise. This analysis extends the current discussion of SEPS adoption beyond internal variables, relying on innovation and diffusion theory. Logistic regression with SEPS adoption as the dependent variable is used to test internal determinants and diffusion measures for the years 1997-2008. Of the internal determinants variables, affluence and government ideology were found to be positive and significant. The results show that regional and neighbor diffusion variables are significant in SEPS adoption decisions-even when accounting for ideological distance from previous adopters.

  12. Trendy solutions. Why do states adopt Sustainable Energy Portfolio Standards?

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, Jess [Georgia Institute of Technology, 685 Cherry Street, Atlanta, GA 30332-0345 (United States)

    2009-08-15

    Thirty-four states had adopted Sustainable Energy Portfolio Standards (SEPS) or similar goals by the end of 2008, with 14 adoptions since 2006. There appears to be something trendy about SEPS and states may adopt SEPS when internal variables would indicate otherwise. This analysis extends the current discussion of SEPS adoption beyond internal variables, relying on innovation and diffusion theory. Logistic regression with SEPS adoption as the dependent variable is used to test internal determinants and diffusion measures for the years 1997-2008. Of the internal determinants variables, affluence and government ideology were found to be positive and significant. The results show that regional and neighbor diffusion variables are significant in SEPS adoption decisions - even when accounting for ideological distance from previous adopters. (author)

  13. Trendy solutions: Why do states adopt Sustainable Energy Portfolio Standards?

    International Nuclear Information System (INIS)

    Chandler, Jess

    2009-01-01

    Thirty-four states had adopted Sustainable Energy Portfolio Standards (SEPS) or similar goals by the end of 2008, with 14 adoptions since 2006. There appears to be something trendy about SEPS and states may adopt SEPS when internal variables would indicate otherwise. This analysis extends the current discussion of SEPS adoption beyond internal variables, relying on innovation and diffusion theory. Logistic regression with SEPS adoption as the dependent variable is used to test internal determinants and diffusion measures for the years 1997-2008. Of the internal determinants variables, affluence and government ideology were found to be positive and significant. The results show that regional and neighbor diffusion variables are significant in SEPS adoption decisions-even when accounting for ideological distance from previous adopters.

  14. Optimal synthesis and operation of advanced energy supply systems for standard and domotic home

    International Nuclear Information System (INIS)

    Buoro, Dario; Casisi, Melchiorre; Pinamonti, Piero; Reini, Mauro

    2012-01-01

    Highlights: ► Definition of an optimization model for a home energy supply system. ► Optimization of the energy supply system for standard and domotic home. ► Strong improvement can be achieved adopting the optimal system in standard and domotic home. ► The improvements are consistent if supply side and demand side strategies are applied together. ► Solutions with internal combustion engines are less sensible to market price of electricity and gas. - Abstract: The paper deals with the optimization of an advanced energy supply systems for two dwellings: a standard home and an advanced domotic home, where some demand side energy saving strategies have been implemented. In both cases the optimal synthesis, design and operation of the whole energy supply system have been obtained and a sensitivity analysis has been performed, by introducing different economic constraints. The optimization model is based on a Mixed Integer Linear Program (MILP) and includes different kinds of small-scale cogenerators, geothermal heat pumps, boilers, heat storages, solar thermal and photovoltaic panels. In addition, absorption machines, supplied with cogenerated heat, can be used instead of conventional electrical chiller to face the cooling demand. The aim of the analysis is to address the question if advanced demand strategies and supply strategies have to be regarded as alternatives, or if they have to be simultaneously applied, in order to obtain the maximum energy and economic benefit.

  15. Alternate performance standard project: Interpreting the post-construction test

    International Nuclear Information System (INIS)

    Williamson, A.D.; McDonough, S.E.

    1993-01-01

    The paper describes the results of a project commissioned by the State of Florida, in cooperation with the US Environmental Protection Agency, as one portion of the Florida Radon Research Program (FRRP). The purpose of the FRRP is to provide technical support for a statewide Building Standard for Radon-Resistant Construction currently in the rulemaking process. In this case the information provides technical background for a post-construction radon test specified as a performance element of the code which accompanies the prescriptive alternative that does not incorporate active radon reduction systems

  16. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1980-01-01

    The actual way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method mostly brings best performance parameters for cameras but it has nothing in common with the use of a camera in clinical practice. Particular in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. Therefore it is important to have test conditions of radionuclide imaging devices, that will approach as best as practicable the measuring conditions in clinical applications. It is therefore a good news that the International Electrochemical Commission IEC has prepared a draft 'Characteristics and test conditions of radionuclide imaging devices' which is now submitted to the national committees for formal approval under the Six Months' Rule. Some essential points of this document are discussed in the paper. (orig.) [de

  17. Essays in energy economics: An inquiry into Renewable Portfolio Standards

    Science.gov (United States)

    Lamontagne, Laura Marie

    In an attempt to motivate the transition away from fossil fuels, reduce carbon emissions and diversify electricity supply, twenty-nine states and the District of Columbia have adopted a Renewable Portfolio Standard (RPS). An RPS is a form of regulation that requires increased electricity production from renewable energy sources. These standards vary by state but generally require a minimum percentage of electricity generation to come from renewable technologies by a predetermined date. In the first chapter I examine the effect of the adoption of an RPS on electricity rates, making use of the increased availability of data since several policies' adoption. Using a fifty state panel over the years 1990-2010, this study uses a difference-in-difference and a fixed effects estimation to measure how the adoption of an RPS affects the price of electricity in state markets. Empirical findings show that states that have adopted an RPS have approximately a 20% higher all-retail electricity price than states that do not have RPS. Following the adoption of this regulation, a state can expect to see electricity prices rise by roughly 5% on average per year relative to states with no RPS. Once the legislation has been in place for almost a decade, electricity rates begin to dramatically increase upwards of 10% per year. In the second chapter, I observe the economic, social and political factors that prompt a state to adopt a Renewable Portfolio Standard. I estimate a probit model to determine the probability a state will adopt an RPS in a year given its present political and economic climate. Results show that a deregulated electricity market, a high per-capita GDP, a strong democratic presence in the state legislature, high renewable capacity, and a strong incidence of natural gas are indicators a state will pass an RPS. Whether or not a state is a net importer or exporter of electricity is not a significant indicator of adoption of an RPS within a state. The third chapter

  18. Energy Efficient Graphene Based High Performance Capacitors.

    Science.gov (United States)

    Bae, Joonwon; Kwon, Oh Seok; Lee, Chang-Soo

    2017-07-10

    Graphene (GRP) is an interesting class of nano-structured electronic materials for various cutting-edge applications. To date, extensive research activities have been performed on the investigation of diverse properties of GRP. The incorporation of this elegant material can be very lucrative in terms of practical applications in energy storage/conversion systems. Among various those systems, high performance electrochemical capacitors (ECs) have become popular due to the recent need for energy efficient and portable devices. Therefore, in this article, the application of GRP for capacitors is described succinctly. In particular, a concise summary on the previous research activities regarding GRP based capacitors is also covered extensively. It was revealed that a lot of secondary materials such as polymers and metal oxides have been introduced to improve the performance. Also, diverse devices have been combined with capacitors for better use. More importantly, recent patents related to the preparation and application of GRP based capacitors are also introduced briefly. This article can provide essential information for future study. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  19. 10 CFR 431.97 - Energy efficiency standards and their effective dates.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy efficiency standards and their effective dates. 431.97 Section 431.97 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps Energy Efficiency...

  20. 75 FR 34657 - Energy Efficiency and Sustainable Design Standards for New Federal Buildings

    Science.gov (United States)

    2010-06-18

    ... Efficiency and Sustainable Design Standards for New Federal Buildings AGENCY: Office of Energy Efficiency and....S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Federal Energy Management... June 11, 2010. Cathy Zoi, Assistant Secretary, Energy Efficiency and Renewable Energy. [FR Doc. 2010...

  1. Relating Standardized Visual Perception Measures to Simulator Visual System Performance

    Science.gov (United States)

    Kaiser, Mary K.; Sweet, Barbara T.

    2013-01-01

    Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

  2. Effect of Energy Efficiency Standards on Natural Gas Prices

    Energy Technology Data Exchange (ETDEWEB)

    Carnall, Michael; Dale, Larry; Lekov, Alex

    2011-07-26

    A primary justification for the establishment of energy efficiency standards for home appliances is the existence of information deficiencies and externalities in the market for appliances. For example, when a long-term homeowner purchases a new gas-fired water heater, she will maximize the value of her purchase by comparing the life-cycle cost of ownership of available units, including both total installed cost - purchase price plus installation costs - and operating cost in the calculus. Choice of the appliance with the lowest life-cycle costs leads to the most economically efficient balance between capital cost and fuel cost. However, if the purchaser's expected period of ownership is shorter than the useful life of the appliance, or the purchaser does not pay for the fuel used by the appliance, as is often the case with rental property, fuel cost will be external to her costs, biasing her decision toward spending less on fuel efficiency and resulting in the purchase of an appliance with greater than optimal fuel usage. By imposing an efficiency standard on appliances, less efficient appliances are made unavailable, precluding less efficient purchases and reducing fuel usage. The reduction in fuel demanded by residential users affects the total demand for such fuels as natural gas, for example. Reduced demand implies that residential customers are willing to purchase less gas at each price level. That is, the demand curve, labeled D{sub 0} in Figure 1, shifts to the left to D{sub 1}. If there is no change in the supply function, the supply curve will intersect the demand curve at a lower price. Residential demand is only one component of the total demand for natural gas. It is possible that total demand will decline very little if demand in other sectors increases substantially in response to a decline in the price. If demand does decrease, modeling studies generally confirm the intuition that reductions in demand for natural gas will result in reductions

  3. Standardization of radiation protection measurements in mixed fields of an extended energy range

    International Nuclear Information System (INIS)

    Hoefert, M.; Stevenson, G.R.

    1977-01-01

    The improved ICRU concept of dose equivalent index aims at standardizing both area and personnel dose measurements so that the results on the dosimetry of external irradiations in radiation protection become compatible. It seems that for photon and neutron energies up to 3 and 20 MeV respectively the realization of dose-equivalent index is straightforward, but the inclusion of higher energies and/or other types of radiation will lead both to conceptual and practical difficulties. It will be shown that practical measurements in mixed radiation fields of an extended energy range for protection purposes will overestimate the standardized quantity. While area measurements can be performed to represent a good approximation, greater uncertainties have to be accepted in personnel dosimetry for stray radiation fields around GeV proton accelerators

  4. Evaluation of a draft standard on performance specifications for health physics instrumentation - program overview

    International Nuclear Information System (INIS)

    Kathren, R.L.; Selby, J.M.; Kenoyer, J.L.; Swinth, K.L.

    1983-01-01

    The draft ANSI Standard N42.17 on performance specifications for health physics instrumentation was written in 1981 by a task group that included both manufacturers and users of these instruments as well as representation from the regulatory bodies; the second draft of this standard is currently being evaluated by Pacific Northwest Laboratory. Objectives of this project include the evaluation of the applicability and practicality of the proposed standard and the determination of the degree of conformance of a cross-section of currently available commercial instruments to the proposed standard. This standard is being tested against such instruments as ionization chambers. G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. Radiological, electrical, mechanical, safety, and environmental performance criteria are specified and tests to evaluate conformance are detailed. Specific criteria which are discussed in this draft standard include inspection tests (e.g., readout units, scaling and zero set, decontamination, moisture protection, alarm threshold, battery status indication), AC and battery power requirements, alarm reset, stability, geotropism, response time, accuracy, precision, IER, beta, and neutron energy dependence, radiation overloads, angular dependence, extracameral response, nonionizing electromagnetic radiations, magnetic fields, interfering ionizing radiations, and effect of temperature, humidity, ambient pressure, shock, and vibration. The testing procedures were developed with emphasis on the requirements found in ANSI N42.17 with additional criteria from other draft and current ANSI and IEC standards

  5. Information on the Department of Energy's analyses to determine the need for appliance efficiency standards

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-23

    A historical overview of three separate Department of Energy analyses performed to determine the need for appliance efficiency standards is presented. An identification of the assumptions used in each of the analyses and the conclusions reached in each analysis are covered. Standards for furnaces, water heaters, central air conditioners, refrigerators, ranges/ovens, clothes dryers, freezers, and room air conditioners are considered. (MCW)

  6. The influence of anthropometrics on physical employment standard performance.

    Science.gov (United States)

    Reilly, T; Spivock, M; Prayal-Brown, A; Stockbrugger, B; Blacklock, R

    2016-10-01

    The Canadian Armed Forces (CAF) recently implemented the Fitness for Operational Requirements of CAF Employment (FORCE), a new physical employment standard (PES). Data collection throughout development included anthropometric profiles of the CAF. To determine if anthropometric measurements and demographic information would predict the performance outcomes of the FORCE and/or Common Military Task Fitness Evaluation (CMTFE). We conducted a secondary analysis of data from FORCE research. We obtained bioelectrical impedance and segmental analysis. Statistical analysis included correlation and linear regression analyses. Among the 668 study subjects, as predicted, any task requiring lifting, pulling or moving of an object was significantly and positively correlated (r > 0.67) to lean body mass (LBM) measurements. LBM correlated with stretcher carry (r = 0.78) and with lifting actions such as sand bag drag (r = 0.77), vehicle extrication (r = 0.71), sand bag fortification (r = 0.68) and sand bag lift time (r = -0.67). The difference between the correlation of dead mass (DM) with task performance compared with LBM was not statistically significant. DM and LBM can be used in a PES to predict success on military tasks such as casualty evacuation and manual material handling. However, there is no minimum LBM required to perform these tasks successfully. These data direct future research on how we should diversify research participants by anthropometrics, in addition to the traditional demographic variables of gender and age, to highlight potential important adverse impact with PES design. In addition, the results can be used to develop better training regimens to facilitate passing a PES. © All rights reserved. ‘The Influence of Anthropometrics on Physical Employment Standard Performance’ has been reproduced with the permission of DND, 2016.

  7. Experience with local lymph node assay performance standards using standard radioactivity and nonradioactive cell count measurements.

    Science.gov (United States)

    Basketter, David; Kolle, Susanne N; Schrage, Arnhild; Honarvar, Naveed; Gamer, Armin O; van Ravenzwaay, Bennard; Landsiedel, Robert

    2012-08-01

    The local lymph node assay (LLNA) is the preferred test for identification of skin-sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. To facilitate acceptance of nonradioactive variants, validation authorities have published harmonized minimum performance standards (PS) that the alternative endpoint assay must meet. In the present work, these standards were applied to a variant of the LLNA based on lymph node cell counts (LNCC) run in parallel as a control with the standard LLNA with radioactivity measurements, with threshold concentrations (EC3) being determined for the sensitizers. Of the 22 PS chemicals tested in this study, 21 yielded the same results from standard radioactivity and cell count measurements; only 2-mercaptobenzothiazole was positive by LLNA but negative by LNCC. Of the 16 PS positives, 15 were positive by LLNA and 14 by LNCC; methylmethacrylate was not identified as sensitizer by either of the measurements. Two of the six PS negatives tested negative in our study by both LLNA and LNCC. Of the four PS negatives which were positive in our study, chlorobenzene and methyl salicylate were tested at higher concentrations than the published PS, whereas the corresponding concentrations resulted in consistent negative results. Methylmethacrylate and nickel chloride tested positive within the concentration range used for the published PS. The results indicate cell counts and radioactive measurements are in good accordance within the same LLNA using the 22 PS test substances. Comparisons with the published PS results may, however, require balanced analysis rather than a simple checklist approach. Copyright © 2011 John Wiley & Sons, Ltd.

  8. Comparison of exertion required to perform standard and active compression-decompression cardiopulmonary resuscitation.

    Science.gov (United States)

    Shultz, J J; Mianulli, M J; Gisch, T M; Coffeen, P R; Haidet, G C; Lurie, K G

    1995-02-01

    Active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) utilizes a hand-held suction device with a pressure gauge that enables the operator to compress as well as actively decompress the chest. This new CPR method improves hemodynamic and ventilatory parameters when compared with standard CPR. ACD-CPR is easy to perform but may be more labor intensive. The purpose of this study was to quantify and compare the work required to perform ACD and standard CPR. Cardiopulmonary testing was performed on six basic cardiac life support- and ACD-trained St. Paul, MN fire-fighter personnel during performance of 10 min each of ACD and standard CPR on a mannequin equipped with a compression gauge. The order of CPR techniques was determined randomly with > 1 h between each study. Each CPR method was performed at 80 compressions/min (timed with a metronome), to a depth of 1.5-2 inches, and with a 50% duty cycle. Baseline cardiopulmonary measurements were similar at rest prior to performance of both CPR methods. During standard and ACD-CPR, respectively, rate-pressure product was 18.2 +/- 3.0 vs. 23.8 +/- 1.7 (x 1000, P CPR compared with standard CPR. Both methods require subanaerobic energy expenditure and can therefore be sustained for a sufficient length of time by most individuals to optimize resuscitation efforts. Due to the slightly higher work requirement, ACD-CPR may be more difficult to perform compared with standard CPR for long periods of time, particularly by individuals unaccustomed to the workload requirement of CPR, in general.

  9. Simulation Study of the Energy Performance of Different Space Heating Methods in Plus-energy Housing

    DEFF Research Database (Denmark)

    Schøtt, Jacob; Andersen, Mads E.; Kazanci, Ongun Berk

    2016-01-01

    Due to a shortage of energy resources, the focus on indoor environment and energy use in buildings is increasing which sets higher standards for the performance of HVAC systems in buildings. The variety of available heating systems for both residential buildings and office buildings is therefore...... cases the heat source was a natural gas fired condensing boiler, and for the floor heating cases also an air-to-water heat pump was used to compare two heat sources. The systems were also compared in terms of auxiliary energy use for pumps and fans. The results show that the investigated floor heating...... from the low temperature heating potential since an increased floor covering requires higher average water temperatures in the floor loops and decreases the COP of the heat pump. The water-based heating systems required significantly less auxiliary energy input compared to the air-based heating system...

  10. Standardized assessment of infrared thermographic fever screening system performance

    Science.gov (United States)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  11. Standardized performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 5 5/8 inches

    Science.gov (United States)

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  12. Standard performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 3-7/8 inches

    Science.gov (United States)

    1976-01-01

    Basic test results are given of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes, and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  13. Confronting Regulatory Cost and Quality Expectations. An Exploration of Technical Change in Minimum Efficiency Performance Standards

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Margaret [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stanford Univ., CA (United States); Spurlock, C. Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yang, Hung-Chia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-09-21

    The dual purpose of this project was to contribute to basic knowledge about the interaction between regulation and innovation and to inform the cost and benefit expectations related to technical change which are embedded in the rulemaking process of an important area of national regulation. The area of regulation focused on here is minimum efficiency performance standards (MEPS) for appliances and other energy-using products. Relevant both to U.S. climate policy and energy policy for buildings, MEPS remove certain product models from the market that do not meet specified efficiency thresholds.

  14. Energy efficiency in future wireless networks: cognitive radio standardization requirements

    CSIR Research Space (South Africa)

    Masonta, M

    2012-09-01

    Full Text Available Energy consumption of mobile and wireless networks and devices is significant, indirectly increasing greenhouse gas emissions and energy costs for operators. Cognitive radio (CR) solutions can save energy for such networks and devices; moreover...

  15. Comparison of energy performance requirements levels

    DEFF Research Database (Denmark)

    Spiekman, Marleen; Thomsen, Kirsten Engelund; Rose, Jørgen

    This summary report provides a synthesis of the work within the EU SAVE project ASIEPI on developing a method to compare the energy performance (EP) requirement levels among the countries of Europe. Comparing EP requirement levels constitutes a major challenge. From the comparison of for instance...... the present Dutch requirement level (EPC) of 0,8 with the present Flemish level of E80, it can easily be seen that direct comparison is not possible. The conclusions and recommendations of the study are presented in part A. These constitute the most important result of the project. Part B gives an overview...... of all other project material related to that topic, which allows to easily identify the most pertinent information. Part C lists the project partners and sponsors....

  16. Performance of the standard FAIR equipment controller prototype

    International Nuclear Information System (INIS)

    Rauch, S.; Baer, R.C.; Panschow, W.; Thieme, M.

    2012-01-01

    For the control system of the new FAIR accelerator facility a standard equipment controller, the Scalable Control Unit (SCU), is presently under development. First prototypes have already been tested in real applications. The controller combines an *86 COM Express TM Board and an Altera Arria TM II FPGA. Over a parallel bus interface called the SCU bus, up to 12 slave boards can be controlled. Communication between CPU and FPGA is done by a PCIe link. We discuss the real time behaviour between the Linux OS and the FPGA Hardware. For the test, a Front-End Software Architecture (FESA) class, running under Linux, communicates with the PCIe bridge in the FPGA. Although we are using PCIe only for single 32 bit wide accesses to the FPGA address space, the performance still seems sufficient. The tests showed an average response time to IRQs of 50 μs with a 1.6 GHz Intel Atom CPU. This includes the context change to the FESA user space application and the reply back to the FPGA. Further topics are the bandwidth of the PCIe link for single/burst transfers and the performance of the SCU bus communication. (authors)

  17. International Review of the Development and Implementation of Energy Efficiency Standards and Labeling Programs

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan; Zheng, Nina; Fridley, David

    2012-02-28

    Appliance energy efficiency standards and labeling (S&L) programs have been important policy tools for regulating the efficiency of energy-using products for over 40 years and continue to expand in terms of geographic and product coverage. The most common S&L programs include mandatory minimum energy performance standards (MEPS) that seek to push the market for efficient products, and energy information and endorsement labels that seek to pull the market. This study seeks to review and compare some of the earliest and most well-developed S&L programs in three countries and one region: the U.S. MEPS and ENERGY STAR, Australia MEPS and Energy Label, European Union MEPS and Ecodesign requirements and Energy Label and Japanese Top Runner programs. For each program, key elements of S&L programs are evaluated and comparative analyses across the programs undertaken to identify best practice examples of individual elements as well as cross-cutting factors for success and lessons learned in international S&L program development and implementation. The international review and comparative analysis identified several overarching themes and highlighted some common factors behind successful program elements. First, standard-setting and programmatic implementation can benefit significantly from a legal framework that stipulates a specific timeline or schedule for standard-setting and revision, product coverage and legal sanctions for non-compliance. Second, the different MEPS programs revealed similarities in targeting efficiency gains that are technically feasible and economically justified as the principle for choosing a standard level, in many cases at a level that no product on the current market could reach. Third, detailed survey data such as the U.S. Residential Energy Consumption Survey (RECS) and rigorous analyses provide a strong foundation for standard-setting while incorporating the participation of different groups of stakeholders further strengthen the process

  18. Energy Performance of Hotel Buildings in Lijiang, China

    Directory of Open Access Journals (Sweden)

    Mingfang Tang

    2016-08-01

    Full Text Available The hotel industry in China has experienced rapid growth in the past ten years and made a considerable contribution to the global tourism economy. This paper focuses on the energy performance of hotel buildings in Lijiang, China. Hotel characteristics, daily operational data, and energy use data were collected by carrying out a survey of 24 hotels. The average annual energy use intensity (EUI of four-, three-, two-, and one-star rated hotels was 180.8 kWh/m2, 113.3 kWh/m2, 74.2 kWh/m2, and 70.2 kWh/m2, respectively. Electricity, as the dominant energy source, accounted for 81% of total energy consumption and was used in the operation of air conditioning, lighting, heating, etc. Pearson correlations between EUI showed that hotel star rating, number of guest rooms, room revenue, and number of workers gave a reasonably strong correlation. A regression-based benchmarking model was established to predict EUI, and a standardization process of EUI was illustrated by statistical analysis.

  19. 40 CFR 428.15 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Standards of performance for new...) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Tire and Inner Tube Plants Subcategory § 428.15 Standards of performance for new sources. The following standards of performance...

  20. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  1. Environmental impact of energy standards - Perspectives for Swiss building; Umweltwirkungen von Energiestandards. Perspektiven fuer den Gebaeudepark Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Dettli, R.; Baur, M.; Philippen, D. [Econcept AG, Zuerich (Switzerland); Frischknecht, R.; Faist Emmenegger, M. [ESU-Services GmbH, Uster (Switzerland)

    2006-12-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) deals with the effects energy standards have in the environmental area. First of all, the buildings examined, system limits and reference parameters and indicators are defined. The standards examined, types of building and energy systems used are dealt with, as are energy performance figures and Swiss standards such as SIA 380/1, MuKEn, Minergie and Minergie-P. The environmental loading caused by building activities is discussed both in general as well as for various particular standards. The influence of various factors such as the use of heat pumps, the electricity mix used and buildings with oil heating is discussed. The results for new and refurbished buildings are examined and future developments in the Swiss residential buildings area and their environmental impact are discussed. A comprehensive annex completes the report.

  2. Energy efficiency performance contracts in the school environment; Contrats de performance energetique dans le milieu scolaire

    Energy Technology Data Exchange (ETDEWEB)

    Drouin, J. [Quebec Ministere de l' Education, Ste-Foy, PQ (Canada)

    1999-12-01

    An overview of new regulations concerning the awarding of energy performance contracts by school boards in the province of Quebec is provided. The article deals with buildings belonging to boards of education that are wholly or primarily utilised for educational purposes. It provides an inventory of such buildings and statistical information about about energy consumption and energy-related costs of educational facilities during the school years 1996/1997 and 1997/1998. Regarding the new regulations, the principal change appears to be that school boards are required to award construction or building services contracts estimated to cost between $50,000 and $100,000 either by public requests for tenders, or by invitation; construction or building services contracts whose cost exceeds $100,000 must be awarded by public tender. In effect, to meet the energy efficiency criteria specified in the new regulations, school boards are obliged to call for bids on any project that contribute to the energy efficiency of school buildings whose cost is estimated to exceed $50,000. The objective of the new regulation is to encourage the consideration of energy efficiency standards by school boards, and by potential contractors. The regulations also prescribe the method of requesting bids and specifies the energy efficiency criteria bidders must meet in order to be eligible.

  3. High-performance piezoelectric nanogenerators for self-powered nanosystems: quantitative standards and figures of merit

    Science.gov (United States)

    Wu, Wenzhuo

    2016-03-01

    Harvesting energies from the atmosphere cost-effectively is critical for both addressing worldwide long-term energy needs at the macro-scale, and achieving the sustainable maintenance-free operation of nanodevices at the micro-scale (Wang and Wu 2012 Angew. Chem. Int. Ed. 51 11700-21). Piezoelectric nanogenerator (NG) technology has demonstrated its great application potential in harvesting the ubiquitous and abundant mechanical energy. Despite of the progress made in this rapidly-advancing field, a fundamental understanding and common standard for consistently quantifying and evaluating the performance of the various types of piezoelectric NGs is still lacking. In their recent study Crossley and Kar-Narayan (2015 Nanotechnology 26 344001), systematically investigated dynamical properties of piezoelectric NGs by taking into account the effect of driving mechanism and load frequency on NG performance. They further defined the NGs’ figures of merit as energy harvested normalized by applied strain or stress for NGs under strain-driven or stress-driven conditions, which are commonly seen in the vibrational energy harvesting. This work provides new insight and a feasible approach for consistently evaluating piezoelectric nanomaterials and NG devices, which is important for designing and optimizing nanoscale piezoelectric energy harvesters, as well as promoting their applications in emerging areas e.g. the internet of things, wearable devices, and self-powered nanosystems.

  4. Strategic technology policy as a supplement to renewable energy standards

    NARCIS (Netherlands)

    Fischer, Carolyn; Greaker, Mads; Rosendahl, Knut Einar

    2018-01-01

    In many regions, renewable energy targets are a primary decarbonization policy. Most of the same jurisdictions also subsidize the manufacturing and/or deployment of renewable energy technologies, some being sufficiently aggressive as to engender WTO disputes. We consider a downstream energy-using

  5. Unintended anchors: Building rating systems and energy performance goals for U.S. buildings

    International Nuclear Information System (INIS)

    Klotz, Leidy; Mack, Daniel; Klapthor, Brent; Tunstall, Casey; Harrison, Jennilee

    2010-01-01

    In the U.S., where buildings account for 40% of energy use, commercial buildings use more energy per unit area than ever before. However, exemplary buildings demonstrate the feasibility of much better energy performance at no additional first cost. This research examines one possible explanation for this inconsistency. The aim is to investigate whether the anchoring bias, which refers to our tendency to gravitate towards a pre-defined standard regardless of its relevance, influences energy performance goals in building design. The scope examines professionals who help set energy performance goals for U.S. buildings. Prior to being asked to set an energy performance goal, these professionals were randomly directed to one of three series of questions. One series set an anchor of 90% energy reduction beyond standard practice, one set a 30% anchor, and one set no anchor. Respondents exposed to the 90% anchor, and respondents exposed to no anchor at all, set higher energy performance goals than respondents exposed to the 30% anchor. These results suggest that building rating systems that only reward incremental energy improvements may inadvertently create anchors, thereby discouraging more advanced energy performance goals and inhibiting energy performance that is technically and economically feasible.

  6. 78 FR 20097 - Energy Savings Performance Contracts

    Science.gov (United States)

    2013-04-03

    ... procedures, scope definition, Measurement and Verification (M&V), financing procurement, and definition of... government. More than $2.71 billion has been invested in Federal energy efficiency and renewable energy... more than $7.18 billion of cumulative energy cost savings for the Federal Government. While FEMP has...

  7. Energy performance of the low-energy house in Greenland

    DEFF Research Database (Denmark)

    Kragh, Jesper; Svendsen, Svend

    2005-01-01

    by ventilation heat recovery (90% efficiency) specially designed for arctic conditions, by using thicker insulation in walls (300 mm) and roof/floor (350 mm), and by using solar hot water heating (3250 kWh/year). The building is intended to enhance sustainability in the building sector in Greenland....... energy gain, efficient ventilation system with heat recovery and solar heating. In this paper the results of a calculation of the energy consumption of low-energy house is presented. The calculation was done using the program BSim2002 [1] and a new weather test reference year based on climatic data......The object of the low-energy house in Sisimiut in Greenland was to build a house with an energy consumption less than 80 kWh/m² corresponding to half the energy frame of the coming building code. Therefore the focus in this project has been on large insulation thicknesses, windows with high net...

  8. 40 CFR 417.85 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.85 Standards of performance for new sources. The following standards of...

  9. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  10. Labeling programs and efficiency standards to control the energy consumption of household appliances: current situation, main results and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Menanteau, Ph.

    2000-09-01

    To control the rise in electricity consumption for specific uses, the industrialized countries started by introducing special programs aimed at improving energy efficiency. Among the different instruments available, labeling programs and minimum energy performance standards (MEPS) have proved to be very effective. The first part of this document presents the current situation, the main results and recommendations concerning the labeling programs and efficiency standards to control the energy consumption of household appliances. This analyze is done for each country in details providing the name of the program or measure, the date of implementation, the objective and the main characteristics of the program, the impacts and evaluation. (A.L.B.)

  11. A review on test procedure, energy efficiency standards and energy labels for room air conditioners and refrigerator-freezers

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Saidur, R. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2010-09-15

    Air conditioners and refrigerator-freezers are major energy users in a household environment and hence efficiency improvement of these appliances can be considered as an important step to reduce their energy consumption along with environmental pollution prevention. Energy efficiency standards and labels are commonly used tools to reduce the energy uses for household appliances for many countries around the world. The first step towards adopting energy efficiency standards is to establish a test procedure for rating and testing of an appliance. It may be mentioned that an energy test procedure is the technical foundation for energy efficiency standards, energy labels, and other related programs. This paper reviews requirements and specifications of various international test standards for testing and rating of room air conditioners and refrigerators. A review on the development of the energy efficiency standards has been provided as well. Finally, energy labels that provide some useful information for identifying energy efficient products have been reviewed for these appliances. It may be stated that the review will be useful for the developing countries who wish to develop these energy savings strategies. It is also expected to be useful to revise the existing strategies for a few selected countries who already implemented these strategies earlier. (author)

  12. 40 CFR 463.24 - New source performance standards.

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY Cleaning Water Subcategory § 463... standards (i.e., mass of pollutant discharged) calculated by multiplying the average process water usage... process water usage flow rate for the new source cleaning water processes from the permittee. ...

  13. Recommendations for energy conservation standards for new residential buildings - volume 3: Introduction and Background to the Standard Development Effort

    Energy Technology Data Exchange (ETDEWEB)

    1989-05-01

    The Energy Conservation for New Buildings Act of 1976, as amended, 42 U.S.C Section 6831 et. seq. requires the US Department of Energy to issue energy conservation standards for the design of new residential and commercial buildings. The standards will be mandatory only for the design of new federal buildings, and will serve as voluntary guidelines for the design of new non-federal buildings. This report documents the development and testing of a set of recommendations, from the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc. (ASHRAE) Special Projects Committee No. 53, designed to provide the technical foundation for the Congressionally-mandated energy standard for new residential buildings. The recommendations have been developed over the past 25 months by a multidisciplinary project team, under the management of the US Department of Energy and its prime contractor, Pacific Northwest Laboratory. Volume III -- Introduction and Background to the Standard Development Effort is a description of the Standard development process and contains the rationale for the general approach and specific criteria contained within the recommendations.

  14. Performance profiles of major energy producers 1996

    International Nuclear Information System (INIS)

    1998-01-01

    This publication examines developments in the operations of the major US e energy-producing companies on a corporate level, by major line of business, by major function within each line of business, and by geographic area. In 1996, 24 companies filed Form EIA-28. The analysis and data presented in this report represents the operations of the Financial Reporting System companies in the context of their worldwide operations and in the context of the major energy markets which they serve. Both energy and nonenergy developments of these companies are analyzed. Although the focus is on developments in 1996, important trends prior to that time are also featured. Sections address energy markets in 1996; key financial developments; oil and gas exploration, development, and production; downstream petroleum in 1996; coal and alternative energy; and foreign direct investment in US energy. 30 figs., 104 tabs

  15. Performance profiles of major energy producers 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This publication examines developments in the operations of the major US e energy-producing companies on a corporate level, by major line of business, by major function within each line of business, and by geographic area. In 1996, 24 companies filed Form EIA-28. The analysis and data presented in this report represents the operations of the Financial Reporting System companies in the context of their worldwide operations and in the context of the major energy markets which they serve. Both energy and nonenergy developments of these companies are analyzed. Although the focus is on developments in 1996, important trends prior to that time are also featured. Sections address energy markets in 1996; key financial developments; oil and gas exploration, development, and production; downstream petroleum in 1996; coal and alternative energy; and foreign direct investment in US energy. 30 figs., 104 tabs.

  16. Solar energy photovoltaic technology: proficiency and performance

    International Nuclear Information System (INIS)

    2006-01-01

    Total is committed to making the best possible of the planet's fossil fuel reserves while fostering the emergence of other solutions, notably by developing effective alternatives. Total involves in photovoltaics when it founded in 1983 Total Energies, renamed Tenesol in 2005, a world leader in the design and installation of photovoltaic solar power systems. This document presents Total's activities in the domain: the global challenge of energy sources and the environment, the energy collecting by photovoltaic electricity, the silicon technology for cell production, solar panels and systems to distribute energy, research and development to secure the future. (A.L.B.)

  17. Data Center Energy Efficiency Standards in India: Preliminary Findings from Global Practices

    Energy Technology Data Exchange (ETDEWEB)

    Raje, Sanyukta; Maan, Hermant; Ganguly, Suprotim; Singh, Tanvin; Jayaram, Nisha; Ghatikar, Girish; Greenberg, Steve; Kumar, Satish; Sartor, Dale

    2015-06-01

    Global data center energy consumption is growing rapidly. In India, information technology industry growth, fossil-fuel generation, and rising energy prices add significant operational costs and carbon emissions from energy-intensive data centers. Adoption of energy-efficient practices can improve the global competitiveness and sustainability of data centers in India. Previous studies have concluded that advancement of energy efficiency standards through policy and regulatory mechanisms is the fastest path to accelerate the adoption of energy-efficient practices in the Indian data centers. In this study, we reviewed data center energy efficiency practices in the United States, Europe, and Asia. Using evaluation metrics, we identified an initial set of energy efficiency standards applicable to the Indian context using the existing policy mechanisms. These preliminary findings support next steps to recommend energy efficiency standards and inform policy makers on strategies to adopt energy-efficient technologies and practices in Indian data centers.

  18. Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 through 2012

    Energy Technology Data Exchange (ETDEWEB)

    Meyers, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Williams, Alison [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    This paper presents estimates of the key impacts of Federal energy and water conservation standards adopted from 1987 through 2012. The standards for consumer products and commercial and industrial equipment include those set by legislation as well as standards adopted by DOE through rulemaking. In 2012, the standards saved an estimated 3.6 quads of primary energy, which is equivalent to 3% of total U.S. energy consumption. The savings in operating costs for households and businesses totaled $51.4 billion. The average household saved $347 in operating costs as a result of residential and plumbing product standards. The estimated reduction in CO2 emissions associated with the standards in 2012 was 198 million metric tons, which is equivalent to 3% of total U.S. CO2 emissions. The estimated cumulative energy savings over the period 1990-2070 amount to 179 quads. Accounting for the increased upfront costs of more-efficient products and the operating cost (energy and water) savings over the products’ lifetime, the standards have a past and projected cumulative net present value (NPV) of consumer benefit of between $1,104 billion and $1,390 billion, using 7 percent and 3 percent discount rates, respectively. The water conservation standards, together with energy conservation standards that also save water, reduced water use by 1.8 trillion gallons in 2012, and will achieve cumulative water savings by 2040 of 54 trillion gallons. The estimated consumer savings in 2012 from reduced water use amounted to $13 billon.

  19. Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2015

    Energy Technology Data Exchange (ETDEWEB)

    Meyers, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Williams, Alison [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-02-17

    This paper presents estimates of the key impacts of Federal energy and water conservation standards adopted from 1987 through 2015. The standards for consumer products and commercial and industrial equipment include those set by legislation as well as standards adopted by DOE through rulemaking. In 2015, the standards saved an estimated 4.49 quads of primary energy, which is equivalent to 5% of total U.S. energy consumption. The savings in operating costs for households and businesses totaled $63.4 billion. The average household saved $320 in operating costs as a result of residential appliance standards. The estimated reduction in CO2 emissions associated with the standards in 2015 was 238 million metric tons, which is equivalent to 4.3% of total U.S. CO2 emissions. The estimated cumulative energy savings over the period 1990-2090 amount to 216.9 quads. Accounting for the increased upfront costs of more-efficient products and the operating cost (energy and water) savings over the products’ lifetime, the standards have a cumulative net present value (NPV) of consumer benefit of between $1,627 billion and $1,887 billion, using 7 percent and 3 percent discount rates, respectively. The water conservation standards, together with energy conservation standards that also save water, reduced water use by 1.9 trillion gallons in 2015 and estimated cumulative water savings by 2090 amount to 55 trillion gallons. The estimated consumer savings in 2015 from reduced water use amounted to $12 billon.

  20. 78 FR 38735 - Autopsy Performance Criteria: Standards, Guidelines and Best Practices

    Science.gov (United States)

    2013-06-27

    ... DEPARTMENT OF JUSTICE Office of Justice Programs [OJP (NIJ) Docket No. 1626] Autopsy Performance Criteria: Standards, Guidelines and Best Practices AGENCY: National Institute of Justice, DOJ. ACTION... entitled, ``Autopsy Performance Criteria: Standards, Guidelines and Best Practices''. The opportunity to...

  1. 40 CFR 432.105 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS MEAT AND POULTRY PRODUCTS POINT SOURCE CATEGORY Renderers § 432.105 New source... renderer that does not cure cattle hide as part of the plant operations. If a renderer does cure hide, the...

  2. 40 CFR 440.24 - New Source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Aluminum Ore Subcategory § 440.24 New... pollutants discharged in mine drainage from mines producting bauxite ores shall not exceed: Effluent...

  3. Towards measurement and verification of energy performance under the framework of the European directive for energy performance of buildings

    International Nuclear Information System (INIS)

    Burman, Esfand; Mumovic, Dejan; Kimpian, Judit

    2014-01-01

    Directive 2002/91/EC of the European Parliament and Council on the Energy Performance of Buildings has led to major developments in energy policies followed by the EU Member States. The national energy performance targets for the built environment are mostly rooted in the Building Regulations that are shaped by this Directive. Article 3 of this Directive requires a methodology to calculate energy performance of buildings under standardised operating conditions. Overwhelming evidence suggests that actual energy performance is often significantly higher than this standardised and theoretical performance. The risk is national energy saving targets may not be achieved in practice. The UK evidence for the education and office sectors is presented in this paper. A measurement and verification plan is proposed to compare actual energy performance of a building with its theoretical performance using calibrated thermal modelling. Consequently, the intended vs. actual energy performance can be established under identical operating conditions. This can help identify the shortcomings of construction process and building procurement. Once energy performance gap is determined with reasonable accuracy and root causes identified, effective measures could be adopted to remedy or offset this gap. - Highlights: • Building energy performance gap is a negative externality that must be addressed. • A method is proposed to link actual performance to building compliance calculation. • Energy performance gap is divided into procurement and operational gaps. • This framework enables policy makers to measure and address procurement gap. • Building fine-tuning by construction teams could also narrow operational gap

  4. Energy performance contracting - energy saving potential of selected energy conservation measures (ECM)

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, M. (Dansk Energi Analyse A/S, Frederiksberg (Denmark)); Langkilde, G.; Olesen, Bjarne W. (Technical Univ. of Denmark, ICIEE, Kgs. Lyngby (Denmark)); Moerck, O. (Cenergia Energy Consultants, Herlev (Denmark)); Sundman, O. (DONG Energy, Copenhagen (Denmark)); Engelund Thomsen, K. (Aalborg Univ., SBi, Hoersholm (Denmark))

    2008-09-15

    This report has been developed under the research project 'Etablering af grundlag for energitjenester i Danmark' (project number: ENS-33031-0185) under the Danish research programme - EFP. The objective of this project has been to contribute to the utilisation of the large potential for energy conservations in the building sector within the public, industry and service sectors through the development of a better basis for decision making for both the Energy Service Companies (ESCOes) and the building owners. The EU directive on Energy Service Contracting points at the buildings as the area where the biggest potential market for energy services and energy efficiency improvements are. The EFP-project has two parts: (1) A Danish part and (2) participation in the international cooperation project 'Holistic Assesment Tool-Kit on Energy Efficient Retrofit Measures for Government Buildings (EnERGo)', Annex 46 under the IEA R and D program 'Energy Conservation In Buildings And Community Systems' (ECBCS). This report describes the Danish contributions to the IEA projects subtask B, which has a primary objective to develop a database of energy conservation measures (ECM) with descriptions and performance characteristics of these. (au)

  5. Energy performance contracting - energy saving potential of selected energy conservation measures (ECM)

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, M [Dansk Energi Analyse A/S, Frederiksberg (Denmark); Langkilde, G; Olesen, Bjarne W [Technical Univ. of Denmark, ICIEE, Kgs. Lyngby (Denmark); Moerck, O [Cenergia Energy Consultants, Herlev (Denmark); Sundman, O [DONG Energy, Copenhagen (Denmark); Engelund Thomsen, K [Aalborg Univ., SBi, Hoersholm (Denmark)

    2008-09-15

    This report has been developed under the research project 'Etablering af grundlag for energitjenester i Danmark' (project number: ENS-33031-0185) under the Danish research programme - EFP. The objective of this project has been to contribute to the utilisation of the large potential for energy conservations in the building sector within the public, industry and service sectors through the development of a better basis for decision making for both the Energy Service Companies (ESCOes) and the building owners. The EU directive on Energy Service Contracting points at the buildings as the area where the biggest potential market for energy services and energy efficiency improvements are. The EFP-project has two parts: (1) A Danish part and (2) participation in the international cooperation project 'Holistic Assesment Tool-Kit on Energy Efficient Retrofit Measures for Government Buildings (EnERGo)', Annex 46 under the IEA R and D program 'Energy Conservation In Buildings And Community Systems' (ECBCS). This report describes the Danish contributions to the IEA projects subtask B, which has a primary objective to develop a database of energy conservation measures (ECM) with descriptions and performance characteristics of these. (au)

  6. 40 CFR 406.35 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 406.35 Section 406.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 406.35 Standards of performance for new sources. The following standards of performance establish the...

  7. 40 CFR 406.45 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 406.45 Section 406.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 406.45 Standards of performance for new sources. The following standards of performance establish the...

  8. 75 FR 68296 - Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources...

    Science.gov (United States)

    2010-11-05

    ... Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources: Sewage... ``Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources: Sewage... performance standards for new units and emission guidelines for existing units for specific categories of...

  9. 76 FR 18407 - Standards of Performance for New Stationary Sources and Emissions Guidelines for Existing Sources...

    Science.gov (United States)

    2011-04-04

    ... Standards of Performance for New Stationary Sources and Emissions Guidelines for Existing Sources: Hospital... performance standards and emissions guidelines for hospital/medical/infectious waste incinerators by the U.S... amendments to the new source performance standards and emissions guidelines, correcting inadvertent drafting...

  10. Characterizing the energy output generated by a standard electric detonator using shadowgraph imaging

    Science.gov (United States)

    Petr, V.; Lozano, E.

    2017-09-01

    This paper overviews a complete method for the characterization of the explosive energy output from a standard detonator. Measurements of the output of explosives are commonly based upon the detonation parameters of the chemical energy content of the explosive. These quantities provide a correct understanding of the energy stored in an explosive, but they do not provide a direct measure of the different modes in which the energy is released. This optically based technique combines high-speed and ultra-high-speed imaging to characterize the casing fragmentation and the detonator-driven shock load. The procedure presented here could be used as an alternative to current indirect methods—such as the Trauzl lead block test—because of its simplicity, high data accuracy, and minimum demand for test repetition. This technique was applied to experimentally measure air shock expansion versus time and calculating the blast wave energy from the detonation of the high explosive charge inside the detonator. Direct measurements of the shock front geometry provide insight into the physics of the initiation buildup. Because of their geometry, standard detonators show an initial ellipsoidal shock expansion that degenerates into a final spherical wave. This non-uniform shape creates variable blast parameters along the primary blast wave. Additionally, optical measurements are validated using piezoelectric pressure transducers. The energy fraction spent in the acceleration of the metal shell is experimentally measured and correlated with the Gurney model, as well as to several empirical formulations for blasts from fragmenting munitions. The fragment area distribution is also studied using digital particle imaging analysis and correlated with the Mott distribution. Understanding the fragmentation distribution plays a critical role when performing hazard evaluation from these types of devices. In general, this technique allows for characterization of the detonator within 6-8% error

  11. Max Tech Appliance Design: Potential for Maximizing U.S. Energy Savings through Standards

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Desroches, Louis-Benoit; Bolduc, Christopher; Burch, Gabriel; Hosseinzadeh, Griffin; Saltiel, Seth

    2011-05-06

    This study surveyed the technical potential for efficiency improvements in 150 categories of appliances and equipment representing 33 quads of primary energy use across the US economy in 2010 and (1) documented efficient product designs, (2) identified the most promising cross-cutting strategies, and (3) ranked national energy savings potential by end use. Savings were estimated using a method modeled after US Department of Energy priority-setting reports - simplified versions of the full technical and economic analyses performed for rulemakings. This study demonstrates that large savings are possible by replacing products at the end-of-life with ultra-efficient models that use existing technology. Replacing the 50 top energy-saving end-uses (constituting 30 quads of primary energy consumption in 2010) with today's best-on-market equivalents would save {approx}200 quads of US primary energy over 30 years (25% of consumption anticipated there from). For the 29 products for maximum feasible savings potential could be estimated, the savings were twice as high. These results demonstrate that pushing ultra-efficient products to market could significantly escalate carbon emission reductions and is a viable strategy for sustaining large emissions reductions through standards. The results of this analysis were used by DOE for new coverage prioritization, to identify key opportunities for product prototyping and market development, and will leverage future standards rulemakings by identifying the full scope of maximum feasible technology options. High leverage products include advances lighting systems, HVAC, and televisions. High leverage technologies include electronic lighting, heat pumps, variable speed motors, and a host of controls-related technologies.

  12. Models for the energy performance of low-energy houses

    DEFF Research Database (Denmark)

    Andersen, Philip Hvidthøft Delff

    of buildings, the first topic analyzed is the variation of presence of occupants. As buildings get more energy-effcient, internal loads and user-behavior increasingly influence the energy consumption. Most simulation tools use deterministic occupancy profiles to simulate internal loads. However, such occupancy......The aim of this thesis is data-driven modeling of heat dynamics of buildings. Traditionally, thermal modeling of buildings is done using simulation tools which take information about the construction, weather data, occupancy etc. as inputs and generate deterministic energy profiles of the buildings....... The approach to modeling occupants’ presence provides a flexible method where no assumptions in the application. The rest of the thesis deals with statistical modeling of heat dynamics of buildings. First, discrete-time models are applied. Discrete-time models are computationally relatively simple and provide...

  13. Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie E.; McNeil, Michael A.; Leiva Ibanez, Francisco Humberto; Ruiz, Ana Maria; Pavon, Mariana; Hall, Stephen

    2011-06-01

    Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The

  14. Computational Fluid Dynamics and Building Energy Performance Simulation

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Tryggvason, Tryggvi

    An interconnection between a building energy performance simulation program and a Computational Fluid Dynamics program (CFD) for room air distribution will be introduced for improvement of the predictions of both the energy consumption and the indoor environment. The building energy performance...

  15. SSTL I/O Standard Based Environment Friendly Energy Efficient ROM Design on FPGA

    DEFF Research Database (Denmark)

    Bansal, Neha; Bansal, Meenakshi; Saini, Rishita

    2014-01-01

    are operating ROM with the highest operating frequency of 4th generation i7 processor to test the compatibility of this design with the latest hardware in use. When there is no demand of peak performance, then we can save 74.5% clock power, 75% signal power, and 30.83% I/O power by operating our device with 1......Stub Series Terminated Logic (SSTL) is an Input/output standard. It is used to match the impedance of line, port and device of our design under consideration. Therefore, selection of energy efficient SSTL I/O standard among available different class of SSTL logic family in FPGA, plays a vital role...

  16. Recommendations for a proposed standard for performing systems analysis

    International Nuclear Information System (INIS)

    LaChance, J.; Whitehead, D.; Drouin, M.

    1998-01-01

    In August 1995, the Nuclear Regulatory Commission (NRC) issued a policy statement proposing improved regulatory decisionmaking by increasing the use of PRA [probabilistic risk assessment] in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. A key aspect in using PRA in risk-informed regulatory activities is establishing the appropriate scope and attributes of the PRA. In this regard, ASME decided to develop a consensus PRA Standard. The objective is to develop a PRA Standard such that the technical quality of nuclear plant PRAs will be sufficient to support risk-informed regulatory applications. This paper presents examples recommendations for the systems analysis element of a PRA for incorporation into the ASME PRA Standard

  17. Impacts of FDI Renewable Energy Technology Spillover on China’s Energy Industry Performance

    Directory of Open Access Journals (Sweden)

    Weiwei Liu

    2016-08-01

    Full Text Available Environmental friendly renewable energy plays an indispensable role in energy industry development. Foreign direct investment (FDI in advanced renewable energy technology spillover is promising to improve technological capability and promote China’s energy industry performance growth. In this paper, the impacts of FDI renewable energy technology spillover on China’s energy industry performance are analyzed based on theoretical and empirical studies. Firstly, three hypotheses are proposed to illustrate the relationships between FDI renewable energy technology spillover and three energy industry performances including economic, environmental, and innovative performances. To verify the hypotheses, techniques including factor analysis and data envelopment analysis (DEA are employed to quantify the FDI renewable energy technology spillover and the energy industry performance of China, respectively. Furthermore, a panel data regression model is proposed to measure the impacts of FDI renewable energy technology spillover on China’s energy industry performance. Finally, energy industries of 30 different provinces in China based on the yearbook data from 2005 to 2011 are comparatively analyzed for evaluating the impacts through the empirical research. The results demonstrate that FDI renewable energy technology spillover has positive impacts on China’s energy industry performance. It can also be found that the technology spillover effects are more obvious in economic and technological developed regions. Finally, four suggestions are provided to enhance energy industry performance and promote renewable energy technology spillover in China.

  18. Ontario's standard offer programs: moving toward a cleaner energy future

    International Nuclear Information System (INIS)

    Shervill, P.

    2006-01-01

    The Ontario Standard Offer Program is designed to ensure reliable, long-term electricity supply for Ontario. The functional areas of the program are planning, conservation and supply sector development. The long-term plan is to create a self-sustaining electricity market in Ontario with 2700 MW renewable sources by 2010 including wind, waterpower, solar photovoltaic (PV) and biomass

  19. Renewable Portfolio Standards: Understanding Costs and Benefits | Energy

    Science.gov (United States)

    considering the highest cost and lowest benefit outcomes. More Information: Fact Sheet Image of a report cover | Presentation Image of a report cover for A Survey of State-Level Cost and Benefit Estimates of Renewable Portfolio Standards: Understanding Costs and Benefits State policymakers, public utilities commissions, and

  20. Performance of broiler chicken fed multicarbohydrases supplemented low energy diet

    Directory of Open Access Journals (Sweden)

    Kumar Govil

    2017-07-01

    Full Text Available Aim: Objective of this study was to investigate the effect of multicarbohydrases supplementation on performance of broilers fed low energy diet. Materials and Methods: A total of 75 days old chicks were selected and randomly divided into three treatments groups (T1, T2, and T3; each group contained 25 chicks distributed in five replicates of five chicks each. T1 group (positive control was offered control ration formulated as per Bureau of Indian Standards recommendations. In T2 group (negative control ration, metabolizable energy (ME was reduced by 100 kcal/kg diet. T3 group ration was same as that of T2 except that it was supplemented with multicarbohydrases (xylanase at 50 g/ton+mannanase at 50 g/ton+amylase at 40 g/ton. Feed intake and body weight of all experimental birds were recorded weekly. Metabolic trial was conducted for 3 days at the end of experiment to know the retention of nutrients. Results: Significant improvement (p<0.01 was observed in total weight gain, feed conversion efficiency, and performance index in broilers under supplementary group T3 as compared to T1 and T2 groups. Retention of crude protein and ether extract was significantly increased (p<0.05 in T3 group supplemented with multicarbohydrases as compared to other groups. Retention of dry matter, crude fiber, and nitrogen-free extract was comparable in all the three groups. Significantly highest dressed weight, eviscerated weight, and drawn weight (% of live body weight were observed in multicarbohydrases supplemented T3 group, however it was comparable in T1 and T2 groups. Conclusion: It was concluded that the supplementation of multicarbohydrases (xylanase at 50 g/ton+mannanase at 50 g/ton+amylase at 40 g/ton in low energy diet improved overall performance of broilers.

  1. Residential Energy Use and Conservation. Economics, Demographics, and Standards

    Energy Technology Data Exchange (ETDEWEB)

    Brounen, D. [Department of Financial Management, Erasmus University Rotterdam, Rotterdam (Netherlands); Kok, N. [Limburg Institute of Financial Economics LIFE, Maastricht University, Maastricht (Netherlands); Quigley, J.M. [Department of Economics, University of California, Berkeley, CA (United States)

    2011-03-15

    Energy consumption in the residential sector offers an important opportunity for conserving resources. However, much of the current debate regarding energy efficiency in the housing market focuses on the physical and technical determinants of energy consumption, neglecting the role of the economic behavior of resident households. In this paper, we analyze the extent to which the use of gas and electricity is determined by the technical specifications of the dwelling as compared to the demographic characteristics of the occupying household, using a unique set of microeconomic data for a sample of more than 300,000 Dutch homes. The results show that residential gas consumption is determined principally by structural dwelling characteristics, such as the vintage, building type and quality of the home, while electricity consumption varies more directly with household composition, in particular income and family composition. Combining these results with projections on future economic and demographic trends, we find that, absent price increases for residential energy, the aging of the population and their increasing wealth will mostly offset improvements in the energy efficiency of the building stock resulting from policy interventions and natural revitalization.

  2. Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards & Labeling Programs for Copy Machines, External Power Supplies, LED Displays, Residential Gas Cooktops and Televisions

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Nina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fridley, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-03-01

    This report presents a technical review of international minimum energy performance standards (MEPS), voluntary and mandatory energy efficiency labels and test procedures for five products being considered for new or revised MEPS in China: copy machines, external power supply, LED displays, residential gas cooktops and flat-screen televisions. For each product, an overview of the scope of existing international standards and labeling programs, energy values and energy performance metrics and description and detailed summary table of criteria and procedures in major test standards are presented.

  3. Institute for Sustained Performance, Energy, and Resilience (SuPER)

    Energy Technology Data Exchange (ETDEWEB)

    Jagode, Heike [Univ. of Tennessee, Knoxville, TN (United States); Bosilca, George [Univ. of Tennessee, Knoxville, TN (United States); Danalis, Anthony [Univ. of Tennessee, Knoxville, TN (United States); Dongarra, Jack [Univ. of Tennessee, Knoxville, TN (United States); Moore, Shirley [Univ. of Texas, El Paso, TX (United States)

    2016-11-30

    The University of Tennessee (UTK) and University of Texas at El Paso (UTEP) partnership supported the three main thrusts of the SUPER project---performance, energy, and resilience. The UTK-UTEP effort thus helped advance the main goal of SUPER, which was to ensure that DOE's computational scientists can successfully exploit the emerging generation of high performance computing (HPC) systems. This goal is being met by providing application scientists with strategies and tools to productively maximize performance, conserve energy, and attain resilience. The primary vehicle through which UTK provided performance measurement support to SUPER and the larger HPC community is the Performance Application Programming Interface (PAPI). PAPI is an ongoing project that provides a consistent interface and methodology for collecting hardware performance information from various hardware and software components, including most major CPUs, GPUs and accelerators, interconnects, I/O systems, and power interfaces, as well as virtual cloud environments. The PAPI software is widely used for performance modeling of scientific and engineering applications---for example, the HOMME (High Order Methods Modeling Environment) climate code, and the GAMESS and NWChem computational chemistry codes---on DOE supercomputers. PAPI is widely deployed as middleware for use by higher-level profiling, tracing, and sampling tools (e.g., CrayPat, HPCToolkit, Scalasca, Score-P, TAU, Vampir, PerfExpert), making it the de facto standard for hardware counter analysis. PAPI has established itself as fundamental software infrastructure in every application domain (spanning academia, government, and industry), where improving performance can be mission critical. Ultimately, as more application scientists migrate their applications to HPC platforms, they will benefit from the extended capabilities this grant brought to PAPI to analyze and optimize performance in these environments, whether they use PAPI

  4. 78 FR 37723 - Laser Products; Proposed Amendment to Performance Standard

    Science.gov (United States)

    2013-06-24

    ... of products that incorporate lasers are compact disc and DVD players, fax machines, fiber optic and... incorporate lasers are compact disc and DVD players, fax machines, fiber optic and free-air communication... additional training costs associated with learning the new standard, but believe estimated costs would be so...

  5. 40 CFR 471.43 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ....0 at all times. (f) Metal powder production atomization wastewater. Subpart D—NSPS Pollutant or... GUIDELINES AND STANDARDS NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY Precious Metals...—Subpart D—NSPS. There shall be no discharge of process wastewater pollutants. (b) Rolling spent emulsions...

  6. 40 CFR 471.53 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ...) Metal powder production floor wash wastewater—Subpart E—NSPS. There shall be no discharge of process... all times. (i) Metal powder production wastewater. Subpart E—NSPS Pollutant or pollutant property... GUIDELINES AND STANDARDS NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY Refractory Metals...

  7. 76 FR 65653 - New Source Performance Standards (NSPS) Review

    Science.gov (United States)

    2011-10-24

    ... current within their review cycle, there are also multiple standards in different phases of the review... Rock Plants NN 04/16/1982 (47FR16589) 10/17/2000 3 4 (65FR61760) Polymeric Coating of Supporting VVV 09... whether review of a particular NSPS is necessary during the review cycle. A listing of any NSPS for which...

  8. 40 CFR 420.124 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... subject to this subpart shall not exceed the standards set forth below. (a) Galvanizing, terne coating and... hexavalent chromium shall be applicable only to galvanizing operations which discharge wastewaters from the chromate rinse step. 2 Within the range of 6.0 to 9.0. (2) [Reserved] (b) Galvanizing and other coatings—(1...

  9. 40 CFR 463.14 - New source performance standards.

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY Contact Cooling and Heating Water... pollutant discharged), which are calculated by multiplying the average process water usage flow rate for the... 9.0 at all times. The permit authority will obtain the average process water usage flow rate for the...

  10. 40 CFR 463.34 - New source performance standards.

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY Finishing Water Subcategory § 463... process water usage flow rate for the finishing water processes at a new source times the following... usage flow rate for the new source finishing water processes from the permittee. ...

  11. 40 CFR 440.104 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Copper, Lead, Zinc, Gold, Silver, and... copper, lead, zinc, gold, silver, or molybdenum bearing ores or any combination of these ores from open... discharge of process wastewater to navigable waters from mills that use the froth-flotation process alone...

  12. Derivation of Building Energy Use Intensity Targets for ASHRAE Standard 100

    Energy Technology Data Exchange (ETDEWEB)

    Sharp, Terry R [ORNL

    2014-06-01

    The steps to develop the building energy use intensity targets for American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 100, Energy Efficiency in Existing Buildings are outlined in this report. The analyses were conducted by Oak Ridge National Laboratory (ORNL) in collaboration with the ASHRAE Standard 100 committee and Dr. Alexander Zhivov, the subcommittee chair responsible for targets development.

  13. Energy Design Guidelines for High Performance Schools: Tropical Island Climates

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-11-01

    Design guidelines outline high performance principles for the new or retrofit design of K-12 schools in tropical island climates. By incorporating energy improvements into construction or renovation plans, schools can reduce energy consumption and costs.

  14. Performance profiles of major energy producers 1979

    International Nuclear Information System (INIS)

    1981-07-01

    The purpose of this report is to examine year-to-year developments in the operations of 26 major US energy companies on a corporate level and also by major line of energy business and by major functions within each line of business. The period covered is 1977 to 1979. Comparisons of income and investment flow are featured and related to functionally allocated net investment in place. The presentation seeks to identify similarities and dissimilarities in results across lines-of-business activity or by firm size

  15. Assessing the Costs and Benefits of the Superior Energy Performance Program

    Energy Technology Data Exchange (ETDEWEB)

    Therkelsen, Peter; McKane, Aimee; Sabouini, Ridah; Evans, Tracy

    2013-07-01

    Industrial companies are seeking to manage energy consumption and costs, mitigate risks associated with energy, and introduce transparency into reports of their energy performance achievements. Forty industrial facilities are participating in the U.S. DOE supported Superior Energy Performance (SEP) program in which facilities implement an energy management system based on the ISO 50001 standard, and pursue third-party verification of their energy performance improvements. SEP certification provides industrial facilities recognition for implementing a consistent, rigorous, internationally recognized business process for continually improving energy performance and achievement of established energy performance improvement targets. This paper focuses on the business value of SEP and ISO 50001, providing an assessment of the costs and benefits associated with SEP implementation at nine SEP-certified facilities across a variety of industrial sectors. These cost-benefit analyses are part of the U.S. DOE?s contribution to the Global Superior Energy Performance (GSEP) partnership, a multi-country effort to demonstrate, using facility data, that energy management system implementation enables companies to improve their energy performance with a greater return on investment than business-as-usual (BAU) activity. To examine the business value of SEP certification, interviews were conducted with SEP-certified facilities. The costs of implementing the SEP program, including internal facility staff time, are described and a marginal payback of SEP certification has been determined. Additionally, more qualitative factors with regard to the business value and challenges related to SEP and ISO 50001 implementation are summarized.

  16. Improving health, safety and energy efficiency in New Zealand through measuring and applying basic housing standards.

    Science.gov (United States)

    Gillespie-Bennett, Julie; Keall, Michael; Howden-Chapman, Philippa; Baker, Michael G

    2013-08-02

    Substandard housing is a problem in New Zealand. Historically there has been little recognition of the important aspects of housing quality that affect people's health and safety. In this viewpoint article we outline the importance of assessing these factors as an essential step to improving the health and safety of New Zealanders and household energy efficiency. A practical risk assessment tool adapted to New Zealand conditions, the Healthy Housing Index (HHI), measures the physical characteristics of houses that affect the health and safety of the occupants. This instrument is also the only tool that has been validated against health and safety outcomes and reported in the international peer-reviewed literature. The HHI provides a framework on which a housing warrant of fitness (WOF) can be based. The HHI inspection takes about one hour to conduct and is performed by a trained building inspector. To maximise the effectiveness of this housing quality assessment we envisage the output having two parts. The first would be a pass/fail WOF assessment showing whether or not the house meets basic health, safety and energy efficiency standards. The second component would rate each main assessment area (health, safety and energy efficiency), potentially on a five-point scale. This WOF system would establish a good minimum standard for rental accommodation as well encouraging improved housing performance over time. In this article we argue that the HHI is an important, validated, housing assessment tool that will improve housing quality, leading to better health of the occupants, reduced home injuries, and greater energy efficiency. If required, this tool could be extended to also cover resilience to natural hazards, broader aspects of sustainability, and the suitability of the dwelling for occupants with particular needs.

  17. Nearly Zero Energy Standard for Non-Residential Buildings with high Energy Demands—An Empirical Case Study Using the State-Related Properties of BAVARIA

    Directory of Open Access Journals (Sweden)

    Michael Keltsch

    2017-03-01

    Full Text Available The Energy Performance of Buildings Directive (EPBD 2010 calls for the Nearly Zero Energy Building (nZEB Standard for new buildings from 2021 onwards: Buildings using “almost no energy” are powered by renewable sources or by the energy produced by the building itself. For residential buildings, this ambitious new standard has already been reached. But for other building types, this goal is still far away. The potential of these buildings to meet a nZEB Standard was investigated by analyzing ten case studies, representing non-residential buildings with different uses. The analysis shows that the primary characteristics common to critical building types are a dense building context with a very high degree of technical installation (such as hospital, research, and laboratory buildings. The large primary energy demand of these types of buildings cannot be compensated by building- and property-related energy generation, including off-site renewables. If the future nZEB Standard were to be defined with lower requirements because of this, the state-related properties of Bavaria suggest that the real potential energy savings available in at least 85% of all new buildings would be insufficiently exploited. Therefore, it would be more useful to individualize the legal energy verification process for new buildings, to distinguish critical building types such as laboratories and hospitals from the other building types.

  18. Energy Design Guidelines for High Performance Schools: Tropical Island Climates

    Energy Technology Data Exchange (ETDEWEB)

    2004-11-01

    The Energy Design Guidelines for High Performance Schools--Tropical Island Climates provides school boards, administrators, and design staff with guidance to help them make informed decisions about energy and environmental issues important to school systems and communities. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school in tropical island climates. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs.

  19. Force coordination in static manipulation tasks performed using standard and non-standard grasping techniques.

    Science.gov (United States)

    de Freitas, Paulo B; Jaric, Slobodan

    2009-04-01

    We evaluated coordination of the hand grip force (GF; normal component of the force acting at the hand-object contact area) and load force (LF; the tangential component) in a variety of grasping techniques and two LF directions. Thirteen participants exerted a continuous sinusoidal LF pattern against externally fixed handles applying both standard (i.e., using either the tips of the digits or the palms; the precision and palm grasps, respectively) and non-standard grasping techniques (using wrists and the dorsal finger areas; the wrist and fist grasp). We hypothesized (1) that the non-standard grasping techniques would provide deteriorated indices of force coordination when compared with the standard ones, and (2) that the nervous system would be able to adjust GF to the differences in friction coefficients of various skin areas used for grasping. However, most of the indices of force coordination remained similar across the tested grasping techniques, while the GF adjustments for the differences in friction coefficients (highest in the palm and the lowest in the fist and wrist grasp) provided inconclusive results. As hypothesized, GF relative to the skin friction was lowest in the precision grasp, but highest in the palm grasp. Therefore, we conclude that (1) the elaborate coordination of GF and LF consistently seen across the standard grasping techniques could be generalized to the non-standard ones, while (2) the ability to adjust GF using the same grasping technique to the differences in friction of various objects cannot be fully generalized to the GF adjustment when different grasps (i.e., hand segments) are used to manipulate the same object. Due to the importance of the studied phenomena for understanding both the functional and neural control aspects of manipulation, future studies should extend the current research to the transient and dynamic tasks, as well as to the general role of friction in our mechanical interactions with the environment.

  20. Reverse translated and gold standard continuous performance tests predict global cognitive performance in schizophrenia.

    Science.gov (United States)

    Bismark, Andrew W; Thomas, Michael L; Tarasenko, Melissa; Shiluk, Alexandra L; Rackelmann, Sonia Y; Young, Jared W; Light, Gregory A

    2018-04-12

    Attentional dysfunction contributes to functional impairments in schizophrenia (SZ). Sustained attention is typically assessed via continuous performance tasks (CPTs), though many CPTs have limited cross-species translational validity and place demands on additional cognitive domains. A reverse-translated 5-Choice Continuous Performance Task (5C-CPT) for human testing-originally developed for use in rodents-was designed to minimize demands on perceptual, visual learning, processing speed, or working memory functions. To-date, no studies have validated the 5C-CPT against gold standard attentional measures nor evaluated how 5C-CPT scores relate to cognition in SZ. Here we examined the relationship between the 5C-CPT and the CPT-Identical Pairs (CPT-IP), an established and psychometrically robust measure of vigilance from the MATRICS Consensus Cognitive Battery (MCCB) in a sample of SZ patients (n = 35). Relationships to global and individual subdomains of cognition were also assessed. 5C-CPT and CPT-IP measures of performance (d-prime) were strongly correlated (r = 0.60). In a regression model, the 5C-CPT and CPT-IP collectively accounted for 54% of the total variance in MCCB total scores, and 27.6% of overall cognitive variance was shared between the 5C-CPT and CPT-IP. These results indicate that the reverse translated 5C-CPT and the gold standard CPT-IP index a common attentional construct that also significantly overlaps with variance in general cognitive performance. The use of simple, cross-species validated behavioral indices of attentional/cognitive functioning such as the 5C-CPT could accelerate the development of novel generalized pro-cognitive therapeutics for SZ and related neuropsychiatric disorders.

  1. Establishment of standard low energy x-ray, radioprotection levels, for calibration of instruments

    International Nuclear Information System (INIS)

    Oliveira, Eliane Carmo

    1995-01-01

    Seven standard low energy X-rays fields were established, radioprotection level, at the Calibration Laboratory of IPEN. Five of the standard calibration qualities used at the National Physical Laboratory, England, with energies between 16 and 38 keV, and two recommended by the International Standard Organization, with energies of 33 and 48 keV, were reproduced. The calibration conditions, radiotherapy level, from 14 to 21 keV, were also verified. Different portable radiation monitors as ionization chambers and Geiger-Mueller detectors were studied in relation to their energy dependence. (author)

  2. ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Qualitative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Halverson, Mark A.; Rosenberg, Michael I.; Hart, Philip R.; Richman, Eric E.; Athalye, Rahul A.; Winiarski, David W.

    2014-09-04

    This report provides a final qualitative analysis of all addenda to ANSI/ASHRAE/IES Standard 90.1-2010 (referred to as Standard 90.1-2010 or 2010 edition) that were included in ANSI/ASHRAE/IES Standard 90.1-2013 (referred to as Standard 90.1-2013 or 2013 edition). All addenda in creating Standard 90.1-2013 were evaluated for their projected impact on energy efficiency. Each addendum was characterized as having a positive, neutral, or negative impact on overall building energy efficiency.

  3. Search for a Standard Model Higgs Boson with a Dilepton and Missing Energy Signature

    International Nuclear Information System (INIS)

    Gerbaudo, Davide

    2011-01-01

    The subject of this thesis is the search for a standard model Higgs boson decaying to a pair of W bosons that in turn decay leptonically, H → W + W - → (bar (ell))ν(ell)(bar ν). This search is performed considering events produced in p(bar p) collisions at √s = 1.96 TeV, where two oppositely charged lepton candidates (e + e - , e ± μ # -+#, or μ + μ - ), and missing transverse energy, have been reconstructed. The data were collected with the D0 detector at the Fermilab Tevatron collider, and are tested against the standard model predictions computed for a Higgs boson with mass in the range 115-200 GeV. No excess of events over background is observed, and limits on Standard Model Higgs boson production are determined. An interpretation of these limits within the hypothesis of a fourth-generation extension to the standard model is also given. The overall analysis scheme is the same for the three dilepton pairs being considered (e + e - , e ± μ # -+#, or μ + μ - ); this thesis, however, describes in detail the study of the dimuon final state.

  4. Search for a Standard Model Higgs Boson with a Dilepton and Missing Energy Signature

    Energy Technology Data Exchange (ETDEWEB)

    Gerbaudo, Davide [Princeton Univ., NJ (United States)

    2011-09-01

    The subject of this thesis is the search for a standard model Higgs boson decaying to a pair of W bosons that in turn decay leptonically, H → W+W- → $\\bar{ℓ}$vℓ$\\bar{v}$. This search is performed considering events produced in p$\\bar{p}$ collisions at √s = 1.96 TeV, where two oppositely charged lepton candidates (e+e-, e±μ±, or μ+μ}-), and missing transverse energy, have been reconstructed. The data were collected with the D0 detector at the Fermilab Tevatron collider, and are tested against the standard model predictions computed for a Higgs boson with mass in the range 115-200 GeV. No excess of events over background is observed, and limits on Standard Model Higgs boson production are determined. An interpretation of these limits within the hypothesis of a fourth-generation extension to the standard model is also given. The overall analysis scheme is the same for the three dilepton pairs being considered (e+e-, e±μ±, or μ+μ-); this thesis, however, describes in detail the study of the dimuon final state.

  5. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done with a sta...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes....... with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...

  6. 40 CFR 437.14 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY Metals Treatment and Recovery....3 Metal Parameters Antimony 0.111 0.0312 Arsenic 0.0993 0.0199 Cadmium 0.782 0.163 Chromium 0.167 0.0522 Cobalt 0.182 0.0703 Copper 0.659 0.216 Lead 1.32 0.283 Mercury 0.000641 0.000246 Nickel 0.794 0...

  7. Thermal stress, human performance, and physical employment standards.

    Science.gov (United States)

    Cheung, Stephen S; Lee, Jason K W; Oksa, Juha

    2016-06-01

    Many physically demanding occupations in both developed and developing economies involve exposure to extreme thermal environments that can affect work capacity and ultimately health. Thermal extremes may be present in either an outdoor or an indoor work environment, and can be due to a combination of the natural or artificial ambient environment, the rate of metabolic heat generation from physical work, processes specific to the workplace (e.g., steel manufacturing), or through the requirement for protective clothing impairing heat dissipation. Together, thermal exposure can elicit acute impairment of work capacity and also chronic effects on health, greatly contributing to worker health risk and reduced productivity. Surprisingly, in most occupations even in developed economies, there are rarely any standards regarding enforced heat or cold safety for workers. Furthermore, specific physical employment standards or accommodations for thermal stressors are rare, with workers commonly tested under near-perfect conditions. This review surveys the major occupational impact of thermal extremes and existing employment standards, proposing guidelines for improvement and areas for future research.

  8. Standard Guidelines of Care: Performing Procedures in Patients on or Recently Administered with Isotretinoin.

    Science.gov (United States)

    Mysore, Venkataram; Mahadevappa, Omprakash H; Barua, Shyamanta; Majid, Imran; Viswanath, Vishalakshi; Bhat, Ramesh M; Talwar, Suresh; Thurakkal, Salim; Aurangabadkar, Sanjeev J; Chatterjee, Manas; Ganjoo, Anil

    2017-01-01

    Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13- cis -retinoic acid) states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. The Association of Cutaneous Surgeons (I) constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Data were extracted from the literature through a PubMed search using the keywords "isotretinoin," "safety," "scarring," "keloids," "hypertrophic scarring," and "pigmentation." The evidence was then labeled and circulated to all members of task force for review. The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued. The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration.

  9. Factorization of standard model cross sections at ultrahigh energy

    Science.gov (United States)

    Chien, Yang-Ting; Li, Hsiang-nan

    2018-03-01

    The factorization theorem for organizing multiple electroweak boson emissions at future colliders with energy far above the electroweak scale is formulated. Taking the inclusive muon-pair production in electron-positron collisions as an example, we argue that the summation over isospins is demanded for constructing the universal distributions of leptons and gauge bosons in an electron. These parton distributions are shown to have the same infrared structure in the phases of broken and unbroken electroweak symmetry, an observation consistent with the Goldstone equivalence theorem. The electroweak factorization of processes involving protons is sketched, with an emphasis on the subtlety of the scalar distributions. This formalism, in which electroweak shower effects are handled from the viewpoint of factorization theorem for the first time, is an adequate framework for collider physics at ultra high energy.

  10. Impact of the EISA 2007 Energy Efficiency Standard on General Service Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Kantner, Colleen L.S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Alstone, Andrea L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ganeshalingam, Mohan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gerke, Brian F. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hosbach, Robert [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-06-20

    The Energy Policy and Conservation Act of 1975, as amended by the Energy Independence and Security Act of 2007 (EISA 2007), requires that, effective beginning January 1, 2020, the Secretary of Energy shall prohibit the sale of any general service lamp (GSL) that does not meet a minimum efficacy standard of 45 lumens per watt. This is referred to as the EISA 2007 backstop. The U.S. Department of Energy recently revised the definition of the term GSL to include certain lamps that were either previously excluded or not explicitly mentioned in the EISA 2007 definition. For this subset of GSLs, we assess the impacts of the EISA 2007 backstop on national energy consumption, carbon dioxide emissions, and consumer expenditures. To estimate these impacts, we projected the energy use, purchase price, and operating cost of representative lamps purchased during a 30-year analysis period, 2020-2049, for cases in which the EISA 2007 backstop does and does not take effect; the impacts of the backstop are then given by the difference between the two cases. In developing the projection model, we also performed the most comprehensive assessment to date of usage patterns and lifetime distributions for the analyzed lamp types in the United States. There is substantial uncertainty in the estimated impacts, which arises from uncertainty in the speed and extent of the market conversion to solid state lighting technology that would occur in the absence of the EISA 2007 backstop. In our central estimate we find that the EISA 2007 backstop results in significant energy savings of 27 quads and consumer net present value of $120 billion (at a seven percent discount rate) for lamps shipped between 2020 and 2049, and carbon dioxide emissions reduction of 540 million metric tons by 2030 for those GSLs not explicitly included in the EISA 2007 definition of a GSL.

  11. Impacts of the EISA 2007 Energy Efficiency Standard on General Service Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Kantner, Colleen L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Alstone, Andrea L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ganeshalingam, Mohan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gerke, Brian F. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hosbach, Robert [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-01-20

    The Energy Policy and Conservation Act of 1975, as amended by the Energy Independence and Security Act of 2007 (EISA 2007), requires that, effective beginning January 1, 2020, the Secretary of Energy shall prohibit the sale of any general service lamp (GSL) that does not meet a minimum efficacy standard of 45 lumens per watt. This is referred to as the EISA 2007 backstop. The U.S. Department of Energy recently revised the definition of the term GSL to include certain lamps that were either previously excluded or not explicitly mentioned in the EISA 2007 definition. For this subset of GSLs, we assess the impacts of the EISA 2007 backstop on national energy consumption, carbon dioxide emissions, and consumer expenditures. To estimate these impacts, we projected the energy use, purchase price, and operating cost of representative lamps purchased during a 30-year analysis period, 2020-2049, for cases in which the EISA 2007 backstop does and does not take effect; the impacts of the backstop are then given by the difference between the two cases. In developing the projection model, we also performed the most comprehensive assessment to date of usage patterns and lifetime distributions for the analyzed lamp types in the United States. There is substantial uncertainty in the estimated impacts, which arises from uncertainty in the speed and extent of the market conversion to solid state lighting technology that would occur in the absence of the EISA 2007 backstop. In our central estimate we find that the EISA 2007 backstop results in significant energy savings of 27 quads and consumer net present value of $120 billion (at a seven percent discount rate) for lamps shipped between 2020 and 2049, and carbon dioxide emissions reduction of 540 million metric tons by 2030 for those GSLs not explicitly included in the EISA 2007 definition of a GSL.

  12. Draft American National Standard N42.17A: performance specifications for health physics instrumentation

    International Nuclear Information System (INIS)

    Selby, J.M.

    1984-07-01

    The report describes the history of the development of the N42.17 standard on instrument performance, describes the standard itself and its relationship to other standards, and discusses ways the standards might be used on either a voluntary or semi-voluntary basis

  13. 75 FR 63259 - Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources...

    Science.gov (United States)

    2010-10-14

    ... Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources: Sewage... performance standards for new units and emission guidelines for existing units for specific categories of... standards and emission guidelines for large municipal waste combustion units, small municipal waste...

  14. 40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...

  15. ACCESS, Absolute Color Calibration Experiment for Standard Stars: Integration, Test, and Ground Performance

    Science.gov (United States)

    Kaiser, Mary Elizabeth; Morris, Matthew; Aldoroty, Lauren; Kurucz, Robert; McCandliss, Stephan; Rauscher, Bernard; Kimble, Randy; Kruk, Jeffrey; Wright, Edward L.; Feldman, Paul; Riess, Adam; Gardner, Jonathon; Bohlin, Ralph; Deustua, Susana; Dixon, Van; Sahnow, David J.; Perlmutter, Saul

    2018-01-01

    Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. Systematic errors associated with astrophysical data used to probe fundamental astrophysical questions, such as SNeIa observations used to constrain dark energy theories, now exceed the statistical errors associated with merged databases of these measurements. ACCESS, “Absolute Color Calibration Experiment for Standard Stars”, is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35‑1.7μm bandpass. To achieve this goal ACCESS (1) observes HST/ Calspec stars (2) above the atmosphere to eliminate telluric spectral contaminants (e.g. OH) (3) using a single optical path and (HgCdTe) detector (4) that is calibrated to NIST laboratory standards and (5) monitored on the ground and in-flight using a on-board calibration monitor. The observations are (6) cross-checked and extended through the generation of stellar atmosphere models for the targets. The ACCESS telescope and spectrograph have been designed, fabricated, and integrated. Subsystems have been tested. Performance results for subsystems, operations testing, and the integrated spectrograph will be presented. NASA sounding rocket grant NNX17AC83G supports this work.

  16. Standardization in Performance Assessment of Telemetry Tracking Systems

    Science.gov (United States)

    2013-09-01

    for a defense system against ballistic missiles ( Kaplan , 2008). Back then the threat was realized by Germany’s V-2 rocket, the world’s first...Kennedy of Massachusetts ( Kaplan , 2008). “It is the policy of the United States to deploy as soon as is technologically possible an effective... P2 , and P3. The parabolic dish then reflects all this energy onto the focal point, point F. The feed of the antenna, which encloses or houses the

  17. An urban energy performance evaluation system and its computer implementation.

    Science.gov (United States)

    Wang, Lei; Yuan, Guan; Long, Ruyin; Chen, Hong

    2017-12-15

    To improve the urban environment and effectively reflect and promote urban energy performance, an urban energy performance evaluation system was constructed, thereby strengthening urban environmental management capabilities. From the perspectives of internalization and externalization, a framework of evaluation indicators and key factors that determine urban energy performance and explore the reasons for differences in performance was proposed according to established theory and previous studies. Using the improved stochastic frontier analysis method, an urban energy performance evaluation and factor analysis model was built that brings performance evaluation and factor analysis into the same stage for study. According to data obtained for the Chinese provincial capitals from 2004 to 2013, the coefficients of the evaluation indicators and key factors were calculated by the urban energy performance evaluation and factor analysis model. These coefficients were then used to compile the program file. The urban energy performance evaluation system developed in this study was designed in three parts: a database, a distributed component server, and a human-machine interface. Its functions were designed as login, addition, edit, input, calculation, analysis, comparison, inquiry, and export. On the basis of these contents, an urban energy performance evaluation system was developed using Microsoft Visual Studio .NET 2015. The system can effectively reflect the status of and any changes in urban energy performance. Beijing was considered as an example to conduct an empirical study, which further verified the applicability and convenience of this evaluation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Performance of a transmutation advanced device for sustainable energy application

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, C.; Rosales, J.; Garcia, L. [Instituto Superior de Tecnologias y Ciencias Aplicadas (INSTEC), La Habana (Cuba); Perez-Navarro, A.; Escriva, A. [Universidad Politecnica de Valencia, Valencia (Spain). Inst. de Ingenieria Energetica; Abanades, A. [Universidad Politecnica de Madrid (Spain). Grupo de Modelizacion de Sistemas Termoenergeticos

    2009-07-01

    Preliminary studies have been performed to design a device for nuclear waste transmutation and hydrogen generation based on a gas cooled pebble bed accelerator driven system, TADSEA (transmutation advanced device for sustainable energy application). In previous studies we have addressed the viability of an ADS Transmutation device that uses as fuel wastes from the existing LWR power plants, encapsulated in graphite in the form of pebble beds, being cooled by helium which enables high temperatures, in the order of 1200 K, to facilitate hydrogen generation from water either by high temperature electrolysis or by thermo chemical cycles. To design this device several configurations were studied, including several reactors thickness, to achieve the desired parameters, the transmutation of nuclear waste and the production of 100 MW. of thermal power. In this paper we are presenting new studies performed on deep burn in-core fuel management strategy for LWR waste. We analyze the fuel cycle on TADSEA device based on driver and transmutation fuel that were proposed for the General Atomic design of a gas turbine-modular helium reactor. We compare the transmutation results of the three fuel management strategies, using driven and transmutation, and standard LWR spend fuel, and present several parameters that describe the neutron performance of TADSEA nuclear core as the fuel and moderator temperature reactivity coefficients and transmutation chain. (author)

  19. Performance of a transmutation advanced device for sustainable energy application

    International Nuclear Information System (INIS)

    Garcia, C.; Rosales, J.; Garcia, L.; Perez-Navarro, A.; Escriva, A.; Abanades, A.

    2009-01-01

    Preliminary studies have been performed to design a device for nuclear waste transmutation and hydrogen generation based on a gas cooled pebble bed accelerator driven system, TADSEA (transmutation advanced device for sustainable energy application). In previous studies we have addressed the viability of an ADS Transmutation device that uses as fuel wastes from the existing LWR power plants, encapsulated in graphite in the form of pebble beds, being cooled by helium which enables high temperatures, in the order of 1200 K, to facilitate hydrogen generation from water either by high temperature electrolysis or by thermo chemical cycles. To design this device several configurations were studied, including several reactors thickness, to achieve the desired parameters, the transmutation of nuclear waste and the production of 100 MW. of thermal power. In this paper we are presenting new studies performed on deep burn in-core fuel management strategy for LWR waste. We analyze the fuel cycle on TADSEA device based on driver and transmutation fuel that were proposed for the General Atomic design of a gas turbine-modular helium reactor. We compare the transmutation results of the three fuel management strategies, using driven and transmutation, and standard LWR spend fuel, and present several parameters that describe the neutron performance of TADSEA nuclear core as the fuel and moderator temperature reactivity coefficients and transmutation chain. (author)

  20. Energy efficiency as a resource in state portfolio standards: Lessons for more expansive policies

    International Nuclear Information System (INIS)

    Thoyre, Autumn

    2015-01-01

    In this paper, state electricity portfolio standards in the U.S. are analyzed to examine how energy efficiency is being created as a particular kind of resource through this type of climate change governance. Such policies can incentivize energy efficiency by requiring or encouraging electricity providers to meet a certain percentage of their demand through energy efficiency measures. North Carolina’s portfolio standard is used as an in-depth case study to identify factors that are then compared across all 36 states that include energy efficiency as part of a portfolio requirement or goal. The main finding of this study is that state portfolio standards tend to emphasize demand-side energy efficiency, or energy efficiency on the customer’s side of the electricity meter, and only rarely incentivize a full range of both demand-side and supply-side efficiency changes. As a result, the amount of energy efficiency and climate change mitigation benefits that are likely to result from this type of portfolio standard policy tool are limited. From this analysis, lessons are drawn out for crafting stronger portfolio standards that incentivize a wider range of efficiency changes across electricity networks. - Highlights: • Energy efficiency in 36 U.S. state portfolio standard policies was analyzed. • Such standards were found to incentivize mainly demand-side energy efficiency. • Supply-side energy efficiency was rarely incentivized by portfolio standards. • Such framings likely limit the carbon mitigation potential of these policies. • Recommendations are made for more expansive portfolio standard policies.

  1. Impacts of alternative residential energy standards - Rural Housing Amendments Study, Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Balistocky, S.; Bohn, A.A.; Heidell, J.A.; Hendrickson, P.L.; Lee, A.D.; Pratt, R.G.; Taylor, Z.T.

    1985-11-01

    This report has examined the role of manufactured housing in the housing market, the energy impacts of three manufactured housing standards and three site-built standards in 13 cities, and the economic impacts of those standards in 6 cities. The three standards applied to manufactured housing are the HUD Title VI standard (Manufactured Housing Construction and Safety Standards, or MHCSS), the Hud Title II-E standard, and the existing FmHA Title V standard. Those applied to site-built homes are the HUD Minimum Property Standards (MPS), the ASHRAE 90A-80 standard, and the FmHA Title V standard. Based on energy consumption alone, these analyses show that the FmHA Title V standard is the most stringent standard for both housing types (a single-section menufactured home and a single-story detached ''ranch house''). The HUD Title VI standard is the least stringent for manufactured homes, while the HUD Minimum Property Standards are the least stringent for site-built homes. Cost-effectiveness comparisons required by the Act were made for the two prototypical homes. Results of this preliminary economic analysis indicate that none of the site-built standards reflect minimum life-cycle cost as a basic criterion of their development. For manufactured homes, both the FmHA standard and the HUD Title II-E standard reduce life-cycle cost and effect positive first-year cash flows in all cities analyzed when electric resistance heating is assumed. When natural gas heating is used, both standards pass the life-cycle cost test in all cities, but the FmHA standard fails the cash flow test in all but one city. However, in the worst case, net monthly expenditures in the first year are increased by less than $9.

  2. Analysis of free electron laser performance utilizing the National Bureau of Standards' CW microtron

    International Nuclear Information System (INIS)

    Tang, C.M.; Sprangle, P.; Penner, S.; Maruyama, X.K.

    1987-01-01

    The National Bureau of Standards' (NBS) CW racetrack microtron (RTM) will be utilized as a driver for a free electron laser (FEL) oscillator. The NBS RTM possesses many exceptional properties of value for the FEL: i) CW operation, ii) energy from 20-185 MeV, iii) small energy spread and emittance, iv) excellent energy stability, and v) high average power. The 1-D FEL gain formula predicts that the FEL would oscillate at the fundamental approximately from 0.25 μm to 10 μm when up-grading the peak current to ≥ 2 A. In this paper, the authors present 3-D self-consistent numerical results including several realistic effects, such as emittance, betatron oscillations, diffraction and refraction. The results indicate that the design value of the transverse emittance is small enough that it does not degrade the FEL performance for intermediate to long wavelengths, and only slightly degrades the performance at the shortest wavelength under consideration. Due to the good emittance, the current density is high enough that focusing, or guiding, begins to manifest itself for wavelengths > 2.0 μm

  3. Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2013

    Energy Technology Data Exchange (ETDEWEB)

    Meyers, Stephen; Williams, Alison; Chan, Peter

    2014-06-30

    This paper presents estimates of the key impacts of Federal energy and water conservation standards adopted from 1987 through 2013. The standards for consumer products and commercial and industrial equipment include those set by legislation as well as standards adopted by DOE through rulemaking. In 2013, the standards saved an estimated 4.05 quads of primary energy, which is equivalent to 4% of total U.S. energy consumption. The savings in operating costs for households and businesses totaled $56 billion. The average household saved $361 in operating costs as a result of residential and plumbing product standards. The estimated reduction in CO{sub 2} emissions associated with the standards in 2013 was 218 million metric tons, which is equivalent to 4% of total U.S. CO{sub 2} emissions. The estimated cumulative energy savings over the period 1990-2090 amount to 181 quads. Accounting for the increased upfront costs of more-efficient products and the operating cost (energy and water) savings over the products’ lifetime, the standards have a past and projected cumulative net present value (NPV) of consumer benefit of between $1,271 billion and $1,487 billion, using 7 percent and 3 percent discount rates, respectively. The water conservation standards, together with energy conservation standards that also save water, reduced water use by 1.9 trillion gallons in 2013, and will achieve cumulative water savings by 2090 of 55 trillion gallons. The estimated consumer savings in 2013 from reduced water use amounted to $16 billon.

  4. Energy Performance of Verandas in the Building Retrofit Process

    Directory of Open Access Journals (Sweden)

    Rossano Albatici

    2016-05-01

    Full Text Available Passive solar elements for both direct and indirect gains, are systems used to maintain a comfortable living environment while saving energy, especially in the building energy retrofit and adaptation process. Sunspaces, thermal mass and glazing area and orientation have been often used in the past to guarantee adequate indoor conditions when mechanical devices were not available. After a period of neglect, nowadays they are again considered as appropriate systems to help face environmental issues in the building sector, and both international and national legislation takes into consideration the possibility of including them in the building planning tools, also providing economic incentives. Their proper design needs dynamic simulation, often difficult to perform and time consuming. Moreover, results generally suffer from several uncertainties, so quasi steady-state procedures are often used in everyday practice with good results, but some corrections are still needed. In this paper, a comparative analysis of different solutions for the construction of verandas in an existing building is presented, following the procedure provided by the slightly modified and improved Standard EN ISO 13790:2008. Advantages and disadvantages of different configurations considering thermal insulation, windows typology and mechanical ventilation systems are discussed and a general intervention strategy is proposed. The aim is to highlight the possibility of using sunspaces in order to increase the efficiency of the existing building stock, considering ease of construction and economic viability.

  5. Developing the (ASTM) voluntary consensus standards required to help implement the National Energy Plan

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The recommended guide is the first American Society for Testing and Materials (ASTM) matrix in a family of such documents that combined, will help manage the development of the ASTM standards considered necessary to implement the current National Plan for Energy Research, Development, and Demonstration. It is expected that the guide will provide a framework for standards development to complement the nation's research and development in support of critical energy needs. The recommended guide identifies the energy-critical areas that are to be developed, the master ASTM recommended guide for developing the standards required to help the National Plan, the section in which each energy-critical area is covered, and the suggested ASTM lead committee responsible for each area (fossil, solar, geothermal, conservation, fusion, and fission reactor development). A comprehensive matrix to identify the areas of need for which ASTM standards will be required to help implement the National Energy Plan is also presented

  6. Analysis of Potential Benefits and Costs of Adopting a Commercial Building Energy Standard in South Dakota

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, David B.; Cort, Katherine A.; Winiarski, David W.; Richman, Eric E.

    2005-03-04

    The state of South Dakota is considering adopting a commercial building energy standard. This report evaluates the potential costs and benefits to South Dakota residents from requiring compliance with the most recent edition of the ANSI/ASHRAE/IESNA 90.1-2001 Energy Standard for Buildings except Low-Rise Residential Buildings. These standards were developed in an effort to set minimum requirements for the energy efficient design and construction of new commercial buildings. The quantitative benefits and costs of adopting a commercial building energy code are modeled by comparing the characteristics of assumed current building practices with the most recent edition of the ASHRAE Standard, 90.1-2001. Both qualitative and quantitative benefits and costs are assessed in this analysis. Energy and economic impacts are estimated using results from a detailed building simulation tool (Building Loads Analysis and System Thermodynamics [BLAST] model) combined with a Life-Cycle Cost (LCC) approach to assess corresponding economic costs and benefits.

  7. Design Performance Standards for Large Scale Wind Farms

    DEFF Research Database (Denmark)

    Gordon, Mark

    2009-01-01

    of connection into the Eastern Australian power system under the Rules and guidelines set out by AEMC and NEMMCO (AEMO). Where applicable some international practices are also mentioned. Standards are designed to serve as a technical envelope under which wind farm proponents design the plant and maintain...... ongoing technical compliance of the plant during its operational lifetime. This report is designed to provide general technical information for the wind farm connection engineer to be aware of during the process of connection, registration and operation of wind power plants interconnected into the HV TSO......’s network. No special NER Rule has been used in this document, however V30 (year 2009) has been used as the latest reference on some of the topics discussed. Care has been taken to emphasise certain wind farm design and connection issues that could be considered throughout different stages of the wind farm...

  8. Practical performances of MPC for wave energy converters

    DEFF Research Database (Denmark)

    Ferri, Francesco; Tetu, Amelie; Hals, J.

    2016-01-01

    Maximising the efficiency of Wave Energy Converter (WEC) is one of the important tasks toward the exploitation of the wave energy resource. Along with a proper design of the device, an important way to achieve better energy performances is to improve the wave-body interaction by applying an appro...

  9. 76 FR 39245 - Energy Conservation Program: Energy Conservation Standards for Residential Furnaces and...

    Science.gov (United States)

    2011-07-06

    ... Wes.Anderson@ee.doe.gov . Mr. Eric Stas or Ms. Jennifer Tiedeman, U.S. Department of Energy, Office of.... Wesley Anderson (central air conditioners and heat pumps), U.S. Department of Energy, Office of Energy...

  10. Optimal energy management of urban rail systems: Key performance indicators

    International Nuclear Information System (INIS)

    González-Gil, A.; Palacin, R.; Batty, P.

    2015-01-01

    Highlights: • An overall picture of urban rail energy use is provided. • Performance indicators are developed for urban rail system energy optimisation. • A multi-level methodology for assessing energy efficiency measures is presented. - Abstract: Urban rail systems are facing increasing pressure to minimise their energy consumption and thusly reduce their operational costs and environmental impact. However, given the complexity of such systems, this can only be effectively achieved through a holistic approach which considers the numerous interdependences between subsystems (i.e. vehicles, operations and infrastructure). Such an approach requires a comprehensive set of energy consumption-related Key Performance Indicators (KEPIs) that enable: a multilevel analysis of the actual energy performance of the system; an assessment of potential energy saving strategies; and the monitoring of the results of implemented measures. This paper proposes an original, complete list of KEPIs developed through a scientific approach validated by different stakeholders. It consists of a hierarchical list of 22 indicators divided into two levels: 10 key performance indicators, to ascertain the performance of the whole system and complete subsystems; and 12 performance indicators, to evaluate the performance of single units within subsystems, for example, a single rail vehicle or station. Additionally, the paper gives a brief insight into urban rail energy usage by providing an adequate context in which to understand the proposed KEPIs, together with a methodology describing their application when optimising the energy consumption of urban rail systems

  11. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    /10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus...

  12. Improving the road wear performance of heavy vehicles in South Africa using a performance-based standards approach

    CSIR Research Space (South Africa)

    Nordengen, Paul A

    2010-05-01

    Full Text Available of the world to achieve regional harmonisation and effective road use have had limited success. Another approach is to consider performance-based standards (PBS); in this case standards specify the performance required from the operation of a vehicle on a...

  13. Energy efficiency of residential buildings. Energy consumption and investment costs of different building energy standards; Energieeffizienz von Wohngebaeuden. Energieverbraeuche und Investitionskosten energetischer Gebaeudestandards

    Energy Technology Data Exchange (ETDEWEB)

    Beecken, Christoph; Schulze, Stephan [Bow Ingenieure GmbH, Braunschweig (Germany)

    2011-12-15

    In view of the impending energy transition in Germany, turning away from fossil fuels and atomic power and leading to renewable energy sources, the construction of very energy efficient new buildings gains more and more in importance. Because the saving of energy with efficient buildings offers the highest potential to achieve the energy transition without loss of comfort and also complying with the climate protection target of limitation of the carbon dioxide emission. For new buildings in the initial project planning phase, the client needs qualified consulting concerning a reasonable energy standard for his building. The consulting should comprise the multitude of energy efficiency standards and the related financial incentives and not only cover the minimum standard of the German Building Energy Conservation Regulation EnEV (Energieeinsparverordnung). But the architect can hardly quantify the potentials to reduce energy consumption of buildings considering the multitude of existing standards with multifarious effects on energy consumption, technical requirements and building costs. With the help of an example multi-storey residential building in Hannover, current energy standards for residential buildings are compared. Besides the building construction also the building services like heating, hot water generation and ventilation are considered and the most important results concerning energy consumption and investment costs are compared.

  14. A methodology for energy performance classification of residential building stock of Hamirpur

    Directory of Open Access Journals (Sweden)

    Aniket Sharma

    2017-12-01

    Full Text Available In India, there are various codes, standards, guidelines and rating systems launched to make energy intensive and large sized buildings energy efficient whereas independent residential buildings are not covered even though they exist most in numbers of total housing stock. This paper presents a case study methodology for energy performance assessment of existing residential stock of Hamirpur that can be used to develop suitable energy efficiency regulations. The paper discusses the trend of residential development in Hamirpur followed by classification based on usage, condition, predominant material use, ownership size and number of rooms, source of lighting, assets available, number of storey and plot sizes using primary and secondary data. It results in identification of predominant materials used and other characteristics in each of urban and rural area. Further cradle to site embodied energy index of various dominant building materials and their market available alternative materials is calculated from secondary literature and by calculating transportation energy. One representative existing building is selected in each of urban and rural area and their energy performance is evaluated for material embodied energy and operational energy using simulation. Further alternatives are developed based on other dominant materials in each area and evaluated for change in embodied and operational energy. This paper identifies the energy performance of representative houses for both areas and in no way advocates the preference of one type over another. The paper demonstrates a methodology by which energy performance assessment of houses shall be done and also highlights further research.

  15. Dataset on the energy performance of atrium type hotel buildings.

    Science.gov (United States)

    Vujosevic, Milica; Krstic-Furundzic, Aleksandra

    2018-04-01

    The data presented in this article are related to the research article entitled "The Influence of Atrium on Energy Performance of Hotel Building" (Vujosevic and Krstic-Furundzic, 2017) [1], which describes the annual energy performance of atrium type hotel building in Belgrade climate conditions, with the objective to present the impact of the atrium on the hotel building's energy demands for space heating and cooling. This dataset is made publicly available to show energy performance of selected hotel design alternatives, in order to enable extended analyzes of these data for other researchers.

  16. Sustainable Performance in Energy Harvesting - Wireless Sensor Networks

    DEFF Research Database (Denmark)

    Fafoutis, Xenofon; Di Mauro, Alessio; Dragoni, Nicola

    2013-01-01

    In this practical demo we illustrate the concept of "sustainable performance" in Energy-Harvesting Wireless Sensor Networks (EH-WSNs). In particular, for different classes of applications and under several energy harvesting scenarios, we show how it is possible to have sustainable performance when...

  17. Governments should implement energy-efficiency standards and labels--cautiously

    International Nuclear Information System (INIS)

    Wiel, Stephen; McMahon, James E.

    2003-01-01

    Energy-efficiency standards and labels can be the most effective long-term energy-efficiency policy any government can implement. This paper describes: (1) the benefits that can be obtained through this policy, (2) which countries are implementing standards and labels and for which products, (3) the processes they are using at each step along the way including the reasons why each step must be done carefully and thoroughly, and (4) the relationship of standard-setting and labeling to other energy-efficiency policies

  18. Household energy consumption versus income and relative standard of living: A panel approach

    International Nuclear Information System (INIS)

    Joyeux, Roselyne; Ripple, Ronald D.

    2007-01-01

    Our fundamental premise is that energy consumption at the household level is a key indicator of standard of living. We employ state-of-the-art panel cointegration techniques to evaluate the nature of the relationship between income measures and energy consumption measures for seven East Indian Ocean countries. The general finding is that income and household electricity consumption are not cointegrated. Given this finding, we conclude that standard of living measures that rely on income measures and do not include household-level energy consumption information will necessarily miss important indications of both levels and changes of standard of living

  19. Standardization and Green Economic Change - the Case of Energy Efficiency in Buildings

    DEFF Research Database (Denmark)

    Andersen, Maj Munch; Faria, Lourenco

    2015-01-01

    This paper investigates the role of standardization for green economic change using energy efficiency in buildings as a case. Innovation research on standards tends to focus on the competition between competing emerging standards as well as the economic impacts of these. The idea pursued here...... energy efficiency becomes an issue in standardization work using buildings as a case. The paper seeks more specifically to investigate the rise of building related standards generally over time as well as in different technical areas and geographic regions. The hypothesis pursued in this paper...... is that the rise of the green economy can only take place accompanied by considerable institution formation in the form of standards. In this sense, the presence of standards may be seen as an important indicator on the maturity of the greening of the economy. The paper presents early empirical work...

  20. A Note on the Determination of "Acceptable" Performance in Thorndike's Standard of Fair Selection.

    Science.gov (United States)

    Brown, Charles

    1980-01-01

    The determination of acceptable performance in Thorndike's constant ratio standard of fair selection is considered. It is shown that suitable choice of acceptable performance can make any minority-majority selection disparity consistent with Thorndike's standard. A rule for determining acceptable performance which avoids the Petersen-Novick…

  1. 77 FR 31964 - Energy Conservation Program: Energy Conservation Standards for Residential Dishwashers

    Science.gov (United States)

    2012-05-30

    ... Costs (Annualized) of the Standards III. Public Participation A. Submission of Comments B. Public..., DOE received the ``Agreement on Minimum Federal Efficiency Standards, Smart Appliances, Federal... submitted by groups representing manufacturers (the Association of Home Appliance Manufacturers (AHAM...

  2. 75 FR 27227 - Energy Conservation Program: Energy Conservation Standards for Residential Central Air...

    Science.gov (United States)

    2010-05-14

    ...-7335. E-mail: Wes.Anderson@ee.doe.gov . Ms. Elizabeth Kohl, U.S. Department of Energy, Office of the... additional information regarding visiting the Resource Room. FOR FURTHER INFORMATION CONTACT: Mr. Wes Anderson, U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Building...

  3. Constraining early and interacting dark energy with gravitational wave standard sirens: the potential of the eLISA mission

    International Nuclear Information System (INIS)

    Caprini, Chiara; Tamanini, Nicola

    2016-01-01

    We perform a forecast analysis of the capability of the eLISA space-based interferometer to constrain models of early and interacting dark energy using gravitational wave standard sirens. We employ simulated catalogues of standard sirens given by merging massive black hole binaries visible by eLISA, with an electromagnetic counterpart detectable by future telescopes. We consider three-arms mission designs with arm length of 1, 2 and 5 million km, 5 years of mission duration and the best-level low frequency noise as recently tested by the LISA Pathfinder. Standard sirens with eLISA give access to an intermediate range of redshift 1 ∼< z ∼< 8, and can therefore provide competitive constraints on models where the onset of the deviation from ΛCDM (i.e. the epoch when early dark energy starts to be non-negligible, or when the interaction with dark matter begins) occurs relatively late, at z ∼< 6. If instead early or interacting dark energy is relevant already in the pre-recombination era, current cosmological probes (especially the cosmic microwave background) are more efficient than eLISA in constraining these models, except possibly in the interacting dark energy model if the energy exchange is proportional to the energy density of dark energy.

  4. Energy-Efficiency Labels and Standards: A Guidebook forAppliances, Equipment, and Lighting - 2nd Edition

    Energy Technology Data Exchange (ETDEWEB)

    Wiel, Stephen; McMahon, James E.

    2005-04-28

    Energy-performance improvements in consumer products are an essential element in any government's portfolio of energy-efficiency and climate change mitigation programs. Governments need to develop balanced programs, both voluntary and regulatory, that remove cost-ineffective, energy-wasting products from the marketplace and stimulate the development of cost-effective, energy-efficient technology. Energy-efficiency labels and standards for appliances, equipment, and lighting products deserve to be among the first policy tools considered by a country's energy policy makers. The U.S. Agency for International Development (USAID) and several other organizations identified on the cover of this guidebook recognize the need to support policy makers in their efforts to implement energy-efficiency standards and labeling programs and have developed this guidebook, together with the Collaborative Labeling and Appliance Standards Program (CLASP), as a primary reference. This second edition of the guidebook was prepared over the course of the past year, four years after the preparation of the first edition, with a significant contribution from the authors and reviewers mentioned previously. Their diligent participation helps maintain this book as the international guidance tool it has become. The lead authors would like to thank the members of the Communications Office of the Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory for their support in the development, production, and distribution of the guidebook. This guidebook is designed as a manual for government officials and others around the world responsible for developing, implementing, enforcing, monitoring, and maintaining labeling and standards setting programs. It discusses the pros and cons of adopting energy-efficiency labels and standards and describes the data, facilities, and institutional and human resources needed for these programs. It provides guidance on the design

  5. 18 CFR 38.2 - Incorporation by reference of North American Energy Standards Board Wholesale Electric Quadrant...

    Science.gov (United States)

    2010-04-01

    ... reference of North American Energy Standards Board Wholesale Electric Quadrant standards. 38.2 Section 38.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY... UTILITIES § 38.2 Incorporation by reference of North American Energy Standards Board Wholesale Electric...

  6. Methodology for predicting market transformation due to implementation of energy efficiency standards and labels

    International Nuclear Information System (INIS)

    Mahlia, T.M.I.

    2004-01-01

    There are many papers that have been published on energy efficiency standards and labels. However, a very limited number of articles on the subject have discussed the transformation of appliance energy efficiency in the market after the programs are implemented. This paper is an attempt to investigate the market transformation due to implementation of minimum energy efficiency standards and energy labels. Even though the paper only investigates room air conditioners as a case study, the method is also applicable for predicting market transformation for other household electrical appliances

  7. Assessing the performance of Dutch local energy companies

    International Nuclear Information System (INIS)

    Blokhuis, Erik; Advokaat, Bart; Schaefer, Wim

    2012-01-01

    According to binding European Union agreements, the Netherlands has to cover at least 14% of its total energy use with renewable energy sources by 2020. However, the share of renewable energy in the Netherlands is small and hardly increasing. In 2010, renewable energy in the Netherlands accounted for only 3.8% of the national energy use, and has decreased with 0.4% compared to 2009. A cause of the stagnating renewable energy generation in the Netherlands is the absence of a nation-wide, clear and consistent long-term policy on the introduction of renewable energy. In order to overcome the current standstill in renewable energy adoption, several Dutch municipalities take the initiative and establish Local Energy Companies (LECs). However, to date, it is unclear which LEC type performs best. This research aims to compare the performance of existing LECs on three aspects: technology, finance, and organization. Furthermore, the performance of existing LECs is compared with theoretical reference LECs, in order to estimate efficiencies and opportunities for improvements. Finally, the influence of the recent changes in the Dutch subsidy scheme on LEC performance is examined. In order to achieve these aims, the benchmark method Data Envelopment Analysis is employed. - Highlights: ► Dutch Local Energy Companies (LECs) producing heat perform best in cost efficiency. ► Technical efficiency is highest in Dutch Local Energy Companies employing wind energy. ► Theoretical assumptions concerning LEC performance are not yet achieved in practice. ► The self supply model adds to the profitability of LECs, independent from subsidies. ► Recent changes in Dutch subsidy schemes add little to LECs’ financial performance.

  8. Environmental performance evaluation of Beijing's energy use planning

    International Nuclear Information System (INIS)

    Wang Lei; Xu Linyu; Song Huimin

    2011-01-01

    In line with rapid economic development, urban energy consumption is increasing rapidly, resulting in environmental problems. After considering several methods to evaluate the environmental performance of energy use, including: energy ecological footprint, input-output analysis, emergy-exergy analysis, and multi-criteria decision-making, an environmental performance evaluation model is proposed, which combines the analytical hierarchy process, fuzzy extent analysis, and membership degree analysis. In the model, 18 sub-indicators of environmental performance from energy use planning are classified into four categories: structure of energy use and industry, technology and efficiency of energy use, environmental impacts caused by energy use, and the socio-economic benefits of energy use. Membership degree analysis is applied to each indicator. Three energy use scenarios which are, respectively, environment-friendly, technology-led, and economic policy-led are evaluated. The results show that the technology-led energy use planning is best. The sustainable energy use policies are proposed from three aspects, including optimizing the energy use and industrial structure, encouraging development of energy-saving and air pollution control technologies, and enhancing legislation on energy use management. The policies are helpful to optimize the trade-offs between economic growth and environmental protection in Beijing. - Highlights: → Our paper establishes a system of indicators according to the structure of urban energy use planning. → We have created a comprehensive environmental performance evaluation model in the research. → The model and results can serve as an important basis for decision-making to guide local government.

  9. System Energy Assessment (SEA, Defining a Standard Measure of EROI for Energy Businesses as Whole Systems

    Directory of Open Access Journals (Sweden)

    Jay Zarnikau

    2011-10-01

    Full Text Available A more objective method for measuring the energy needs of businesses, System Energy Assessment (SEA, measures the combined impacts of material supply chains and service supply chains, to assess businesses as whole self-managing net-energy systems. The method is demonstrated using a model Wind Farm, and defines a physical measure of their energy productivity for society (EROI-S, a ratio of total energy delivered to total energy expended. Energy use records for technology and proxy measures for clearly understood but not individually recorded energy uses for services are combined for a whole system estimate of consumption required for production. Current methods count only energy needs for technology. Business services outsource their own energy needs to operate, leaving no traceable record. That uncounted business energy demand is often 80% of the total, an amount of “dark energy” hidden from view, discovered by finding the average energy estimated needs for businesses far below the world average energy consumed per dollar of GDP. Presently for lack of information the energy needs of business services are counted to be “0”. Our default assumption is to treat them as “average”. The result is a hard measure of total business demand for energy services, a “Scope 4” energy use or GHG impact assessment. Counting recorded energy uses and discounting unrecorded ones misrepresents labor intensive work as highly energy efficient. The result confirms a similar finding by Hall et al. in 1981 [1]. We use exhaustive search for what a business needs to operate as a whole, tracing internal business relationships rather than energy data, to locate its natural physical boundary as a working unit, and so define a business as a physical rather than statistical subject of scientific study. See also online resource materials and notes [2].

  10. International comparison of energy standards in the building area; Internationaler Vergleich von Energiestandards im Baubereich

    Energy Technology Data Exchange (ETDEWEB)

    Rieder, S.; Balthasar, A. [Institut fuer Politikstudien Interface GmbH, Lucerne (Switzerland); Eichhammer, W.; Reichert, J. [Fraunhofer-Institut Systemtechnik und Innovationsforschung (ISI), Karlsruhe (Germany)

    2005-07-01

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the creation, implementation and effectiveness of energy standards in Switzerland and the four European countries Austria, Germany, the Netherlands and Denmark. The results of the research, which was based on interviews, documents and the literature available, are presented and commented on. The authors are of the opinion that the development of energy-standards and regulations proved to be most difficult in Switzerland as a result of heavily decentralised legislation competencies. Developments in Europe are discussed. As far as the 'sharpness' of legislation is concerned, large differences can be found between the five countries looked at. The possible export of the Swiss 'MINERGIE' standard in other European countries is examined. Recommendations are made for the further development of energy standards.

  11. EPA's high-level waste standards and waste package performance

    International Nuclear Information System (INIS)

    Meyers, S.

    1985-01-01

    The seven assurance requirements EPA was considering were these: (1) Disposal systems shall not depend on active institutional controls for more than 100 years after disposal; (2) Long-term disposal system performance should be monitored for a reasonable time as a supplement to other types of protection; (3) Disposal systems shall be marked and their locations recorded in all appropriate government records; (4) Disposal systems shall be designed with several different types of barriers, both natural and engineered; (5) Sites should not be located where scarce or easily accessible resources are located; (6) Site selection should consider the relative isolation offered by potential alternatives; and (7) Wastes shall be recoverable for a reasonable time after disposal. (orig./PW)

  12. Thermodynamic performance assessment of wind energy systems: An application

    International Nuclear Information System (INIS)

    Redha, Adel Mohammed; Dincer, Ibrahim; Gadalla, Mohamed

    2011-01-01

    In this paper, the performance of wind energy system is assessed thermodynamically, from resource and technology perspectives. The thermodynamic characteristics of wind through energy and exergy analyses are considered and both energetic and exergetic efficiencies are studied. Wind speed is affected by air temperature and pressure and has a subsequent effect on wind turbine performance based on wind reference temperature and Bernoulli's equation. VESTAS V52 wind turbine is selected for (Sharjah/UAE). Energy and exergy efficiency equations for wind energy systems are further developed for practical applications. The results show that there are noticeable differences between energy and exergy efficiencies and that exergetic efficiency reflects the right/actual performance. Finally, exergy analysis has been proven to be the right tool used in design, simulation, and performance evaluation of all renewable energy systems. -- Highlights: → In this research the performance of wind energy system is assessed thermodynamically, from resource and technology perspectives. → Energy and exergy equations for wind energy systems are further developed for practical applications. → Thermodynamic characteristics of wind turbine systems through energetic and exergetic efficiencies are evaluated from January till March 2010. → Exergy efficiency describes the system irreversibility and the minimum irreversibility exists when the wind speed reaches 11 m/s. → The power production during March was about 17% higher than the month of February and 66% higher than January.

  13. Missing transverse energy performance of the CMS detector

    Energy Technology Data Exchange (ETDEWEB)

    Chatrchyan, Serguei [Yerevan Physics Inst. (Armenia); et al.

    2011-09-01

    During 2010 the LHC delivered pp collisions with a centre-of-mass energy of 7 TeV. In this paper, the results of comprehensive studies of missing transverse energy as measured by the CMS detector are presented. The results cover the measurements of the scale and resolution for missing transverse energy, and the effects of multiple pp interactions within the same bunch crossings on the scale and resolution. Anomalous measurements of missing transverse energy are studied, and algorithms for their identification are described. The performances of several reconstruction algorithms for calculating missing transverse energy are compared. An algorithm, called missing-transverse-energy significance, which estimates the compatibility of the reconstructed missing transverse energy with zero, is described, and its performance is demonstrated.

  14. 2010 energy benchmarking report performance of the Canadian office sector

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-04-15

    In 2009, REALpac set a target of reducing energy consumption in office buildings to 20 equivalent kilowatt-hours per square foot by 2015. Following this, REALpac launched a national energy benchmarking survey to create a baseline for building energy performance across Canada; this paper provides the results of that survey. The survey was carried out using a tool which can measure energy use in a meaningful way using building characteristics data and energy use data from utility bills. The survey was conducted on 2009 data, 261 office buildings submitted their data which were then analyzed to provide trends and a baseline. Results showed a variety and diversity of performances and a 28.7 ekWh/ft2 annual mean building energy use intensity was found. This survey demonstrated that several office building owners and managers are taking steps to monitor and minimize energy use in their buildings.

  15. Missing transverse energy performance of the CMS detector

    International Nuclear Information System (INIS)

    2011-01-01

    During 2010 the LHC delivered pp collisions with a centre-of-mass energy of 7 TeV. In this paper, the results of comprehensive studies of missing transverse energy as measured by the CMS detector are presented. The results cover the measurements of the scale and resolution for missing transverse energy, and the effects of multiple pp interactions within the same bunch crossings on the scale and resolution. Anomalous measurements of missing transverse energy are studied, and algorithms for their identification are described. The performance of several reconstruction algorithms for calculating missing transverse energy are compared. An algorithm, called missing-transverse-energy significance, which estimates the compatibility of the reconstructed missing transverse energy with zero, is described, and its performance is demonstrated.

  16. Contribution to the development of a primary standard for high energy neutron beams

    International Nuclear Information System (INIS)

    Mancaux, M.

    1983-12-01

    A tissue equivalent calorimeter, made of Shonka A-150 plastic, has been constructed in order to create a primary standard for high energy neutrons and to establish a calibration procedure for ionization chambers used in neutrontherapy. After a detailed description of the calorimeter and the associated measuring system, the preliminary tests are presented, in particular, the evolution of the response as a function of accumulated dose. The measurements of the total absorbed dose (n + γ) by calorimetry in a neutron beam, in order to determine chambers' calibration factors in terms of absorbed dose to A-150 plastic, have been performed at the Neutrontherapy Unit of the Centre Hospitalier Regional d'Orleans. The uncertainty in the determination of the total absorbed dose to the tissu equivalent material using the new procedure is 3% lower than that obtained with the usual procedure, derived from an exposure calibration [fr

  17. Status and Analysis on Effects of Energy Efficiency Standards for Industrial Boilers in China

    Science.gov (United States)

    Liu, Ren; Chen, Lili; Liu, Meng; Ding, Qing; Zhao, Yuejin

    2017-11-01

    Energy conservation and environmental protection is the basic policy of China, and is an important part of ecological civilization construction. The industrial boilers in China are featured by large quantity, wide distribution, high energy consumption and heavy environmental pollution, which are key problems faced by energy conservation and environmental protection in China. Meanwhile, industrial boilers are important equipment for national economy and people’s daily life, and energy conservation gets through all segments from type selection, purchase, installation and acceptance to fuel management, operation, maintenance and service. China began to implement such national mandatory standards and regulations for industrial boiler as GB24500-2009 The Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades of Industrial Boilers and TSG G002-2010 Supervision Regulation on Energy-Saving Technology for Boilers since 2009, which obviously promote the development of energy conservation of industrial boilers, but there are also some problems with the rapid development of technologies for energy conservation of industrial boilers. In this paper, the implementation of energy efficiency standards for industrial boilers in China and the significance are analyzed based on survey data, and some suggestions are proposed for the energy efficiency standards for industrial boilers.

  18. Viewpoint Mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia

    International Nuclear Information System (INIS)

    Mahlia, T.M.I.; Masjuki, H.H.; Saidur, R.; Amalina, M.A.

    2004-01-01

    Malaysian economy has grown rapidly in the last two decades. This growth has increased the ownership of household electrical appliances including room air conditioners. The number of users of air conditioners is predicted to grow dramatically in Malaysian households in the future. To reduce energy consumption in the residential sector, the Malaysia Energy Commission is considering implementing minimum energy efficiency standards for room air conditioners in early 2004. This paper attempts to predict the potential mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia. The calculations were based on the growth of room air conditioners ownership data in Malaysian households. The study found that the energy efficiency standards for room air conditioners would mitigate a significant amount of emissions in this country

  19. 40 CFR 417.165 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.165 Standards of performance for new sources. The following standards...) For normal liquid detergent operations the following values pertain: Effluent characteristic Effluent...

  20. Review of Consensus Standard Spectra for Flat Plate and Concentrating Photovoltaic Performance

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D.

    2011-09-01

    Consensus standard reference terrestrial solar spectra are used to establish nameplate ratings for photovoltaic device performance at standard reporting conditions. This report describes reference solar spectra developed in the United States and international consensus standards community which are widely accepted as of this writing (June 2011).

  1. Very low energy homes in the United States: Perspectives on performance from measured data

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Danny S. [Florida Solar Energy Center, 1679 Clearlake Rd., Cocoa, FL 32922 (United States)

    2009-05-15

    We present measured annual performance data from a dozen recent-vintage very low energy homes in North America. Many of the designs combine greater energy efficiency with solar electric photovoltaic power in an attempt to create Zero Energy Homes (ZEH). We also provide measured data from the first home constructed to the German Passivhaus standard in the United States. Several projects either exceeded or come very close to true net zero energy when evaluated over a year. The data indicate that very low energy use buildings can very readily be achieved in North America. Annual energy use half that or less than standard housing can be achieved for an equivalent cost of $0.10/kWh from the efficiency investment. In general, the better cost effectiveness seen from energy efficiency measures indicates that greater investment in conservation should be a prerequisite to installation of solar water heating and solar electricity in Zero Energy Homes. However, over emphasis in efficiency is also possible. This suggests that optimization tools such as BEopt and EGUSA, which characterize both renewable resource performance and that also of specific combinations of energy efficiency measures, will best guide designers to locate the most economically favorable mix to reach an energy neutral level. (author)

  2. Performance of a piezoelectric energy harvester in actual rain

    International Nuclear Information System (INIS)

    Wong, Voon-Kean; Ho, Jee-Hou; Chai, Ai-Bao

    2017-01-01

    When raindrops impact on the surface of a piezoelectric beam, strain energy produced by the impinging raindrop will be converted to harvestable electrical energy by the piezoelectric layers in a cantilever beam. The novelty of this study is to investigate the performance of the harvester in actual rain and provide practical insights on implementation. The influences of rain parameters such as rain rate, rainfall depth, raindrop count, and drop size distribution (DSD) are discussed in this study. The raindrops accumulated on the surface of the piezoelectric beam will form a water layer. It is described using added mass coefficient in this study. In an actual rain experiment, a piezoelectric beam with surface area of 0.0018 m 2 is able to produce 2076 μJ of energy over a duration of 301 min. The energy generation of a raindrop impact piezoelectric energy harvester is highly dependent on the rain rate. Due to the inconsistency of the energy generation, the piezoelectric energy harvester would require an integration of suitable energy storage device for continuous operation. Nevertheless, this work shows the feasibility of harvesting raindrop energy using a piezoelectric beam. - Highlights: • The performance of a piezoelectric rain energy harvester is tested in actual rain. • The energy generation is highly dependent on the rain rate. • Practical insights on the implementation of the harvester are discussed. • A total energy of 2076 μJ is generated over a duration of 301 min.

  3. Evaluation of four building energy analysis computer programs against ASHRAE standard 140-2007

    CSIR Research Space (South Africa)

    Szewczuk, S

    2014-08-01

    Full Text Available ) standard or code of practice. Agrément requested the CSIR to evaluate a range of building energy simulation computer programs. The standard against which these computer programs were to be evaluated was developed by the American Society of Heating...

  4. IEEE 1547 and 2030 Standards for Distributed Energy Resources Interconnection and Interoperability with the Electricity Grid

    Energy Technology Data Exchange (ETDEWEB)

    Basso, T.

    2014-12-01

    Public-private partnerships have been a mainstay of the U.S. Department of Energy and the National Renewable Energy Laboratory (DOE/NREL) approach to research and development. These partnerships also include technology development that enables grid modernization and distributed energy resources (DER) advancement, especially renewable energy systems integration with the grid. Through DOE/NREL and industry support of Institute of Electrical and Electronics Engineers (IEEE) standards development, the IEEE 1547 series of standards has helped shape the way utilities and other businesses have worked together to realize increasing amounts of DER interconnected with the distribution grid. And more recently, the IEEE 2030 series of standards is helping to further realize greater implementation of communications and information technologies that provide interoperability solutions for enhanced integration of DER and loads with the grid. For these standards development partnerships, for approximately $1 of federal funding, industry partnering has contributed $5. In this report, the status update is presented for the American National Standards IEEE 1547 and IEEE 2030 series of standards. A short synopsis of the history of the 1547 standards is first presented, then the current status and future direction of the ongoing standards development activities are discussed.

  5. 78 FR 42389 - Energy Conservation Program: Energy Conservation Standards for Residential Clothes Dryers and...

    Science.gov (United States)

    2013-07-16

    ... conditioners without reverse cycle and with louvered sides as 24,999 British thermal units per hour (Btu/ h... and with louvered sides as 25,000 Btu/h, rather than 27,999 Btu/h and 28,000 Btu/h, respectively...: Stephen L. Witkowski, U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy...

  6. Experience implementing energy standards for commercial buildings and its lessons for the Philippines

    Energy Technology Data Exchange (ETDEWEB)

    Busch, John; Deringer, Joseph

    1998-10-01

    Energy efficiency standards for buildings have been adopted in over forty countries. This policy mechanism is pursued by governments as a means of increasing energy efficiency in the buildings sector, which typically accounts for about a third of most nations' energy consumption and half of their electricity consumption. This study reports on experience with implementation of energy standards for commercial buildings in a number of countries and U.S. states. It is conducted from the perspective of providing useful input to the Government of the Philippines' (GOP) current effort at implementing their building energy standard. While the impetus for this work is technical assistance to the Philippines, the intent is to shed light on the broader issues attending implementation of building energy standards that would be applicable there and elsewhere. The background on the GOP building energy standard is presented, followed by the objectives for the study, the approach used to collect and analyze information about other jurisdictions' implementation experience, results, and conclusions and recommendations.

  7. Performance maps for the control of thermal energy storage

    DEFF Research Database (Denmark)

    Finck, Christian; Li, Rongling; Zeiler, Wim

    2017-01-01

    Predictive control in building energy systems requires the integration of the building, building system, and component dynamics. The prediction accuracy of these dynamics is crucial for practical applications. This paper introduces performance maps for the control of water tanks, phase change mat...... material tanks, and thermochemical material tanks. The results show that these performance maps can fully account for the dynamics of thermal energy storage tanks.......Predictive control in building energy systems requires the integration of the building, building system, and component dynamics. The prediction accuracy of these dynamics is crucial for practical applications. This paper introduces performance maps for the control of water tanks, phase change...

  8. Performance outcomes and unwanted side effects associated with energy drinks.

    Science.gov (United States)

    Mora-Rodriguez, Ricardo; Pallarés, Jesús G

    2014-10-01

    Energy drinks are increasingly popular among athletes and others. Advertising for these products typically features images conjuring great muscle power and endurance; however, the scientific literature provides sparse evidence for an ergogenic role of energy drinks. Although the composition of energy drinks varies, most contain caffeine; carbohydrates, amino acids, herbs, and vitamins are other typical ingredients. This report analyzes the effects of energy drink ingredients on prolonged submaximal (endurance) exercise as well as on short-term strength and power (neuromuscular performance). It also analyzes the effects of energy drink ingredients on the fluid and electrolyte deficit during prolonged exercise. In several studies, energy drinks have been found to improve endurance performance, although the effects could be attributable to the caffeine and/or carbohydrate content. In contrast, fewer studies find an ergogenic effect of energy drinks on muscle strength and power. The existing data suggest that the caffeine dose given in studies of energy drinks is insufficient to enhance neuromuscular performance. Finally, it is unclear if energy drinks are the optimal vehicle to deliver caffeine when high doses are needed to improve neuromuscular performance. © 2014 International Life Sciences Institute.

  9. Standard Guidelines of Care: Performing Procedures in Patients on or Recently Administered with Isotretinoin

    Science.gov (United States)

    Mysore, Venkataram; Mahadevappa, Omprakash H.; Barua, Shyamanta; Majid, Imran; Viswanath, Vishalakshi; Bhat, Ramesh M.; Talwar, Suresh; Thurakkal, Salim; Aurangabadkar, Sanjeev J.; Chatterjee, Manas; Ganjoo, Anil

    2017-01-01

    Background: Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13-cis-retinoic acid) states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. Objective: The Association of Cutaneous Surgeons (I) constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Materials and Methods: Data were extracted from the literature through a PubMed search using the keywords “isotretinoin,” “safety,” “scarring,” “keloids,” “hypertrophic scarring,” and “pigmentation.” The evidence was then labeled and circulated to all members of task force for review. Results: The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued. The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration. PMID:29491653

  10. Standard guidelines of care: Performing procedures in patients on or recently administered with isotretinoin

    Directory of Open Access Journals (Sweden)

    Venkataram Mysore

    2017-01-01

    Full Text Available Background: Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13-cis-retinoic acid states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. Objective: The Association of Cutaneous Surgeons (I constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Materials and Methods: Data were extracted from the literature through a PubMed search using the keywords “isotretinoin,” “safety,” “scarring,” “keloids,” “hypertrophic scarring,” and “pigmentation.” The evidence was then labeled and circulated to all members of task force for review. Results: The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued.The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration.

  11. Study on Laws, Regulations and Standards on Energy Efficiency, Energy Conserving and Emission Reduction of Industrial Boilers in EU

    Science.gov (United States)

    Liu, Ren; Zhao, Yuejin; Chen, Haihong; Liang, Xiuying; Yang, Ming

    2017-12-01

    Industrial boilers are widely applied in such fields as factory power, building heating, and people’s lives; China is the world’s largest producer and user of industrial boilers, with very high annual energy consumption; clear requirements have been put forward by China on the energy efficiency since the “11th Five-year Plan” with the hope to save energy and reduce emission by means of energy efficiency standards and regulations on the supervision and control of various special equipment. So far, the energy efficiency of industrial boilers in China has been improved significantly but there is still a gap with the EU states. This paper analyzes the policies of energy efficiency, implementation models and methods of supervision and implementation at the EU level from laws, regulations, directives as well as standards; the paper also puts forward suggestions of energy conserving and emission reduction on the improvement of energy conserving capacity of industrial boilers in China through studying the legislations and measures of the developed countries in energy conserving of boilers.

  12. Analysis on effects of energy efficiency regulations & standards for industrial boilers in China

    Science.gov (United States)

    Liu, Ren; Chen, Lili; Zhao, Yuejin; Liu, Meng

    2017-11-01

    The industrial boilers in China are featured by large quantity, wide distribution, high energy consumption and heavy environmental pollution, which are key problems faced by energy conservation and environmental protection in China. Meanwhile, industrial boilers are important equipment for national economy and people’s daily life, and energy conservation gets through all segments from type selection, purchase, installation and acceptance to fuel management, operation, maintenance and service. China began to implement such national mandatory standards and regulations for industrial boiler as GB24500-2009 The Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades of Industrial Boilers and TSG G002-2010 Supervision Regulation on Energy-Saving Technology for Boilers since 2009, which obviously promote the development of energy conservation of industrial boilers, but there are also some problems with the rapid development of technologies for energy conservation of industrial boilers. In this paper, the implementation of energy efficiency standards for industrial boilers in China and the significance are analyzed based on survey data, and some suggestions are proposed for the energy efficiency standards for industrial boilers. Support by Project 2015424050 of Special Fund for quality control Research in the Public Interest

  13. Medicaid management information systems performance standards: Health Care Financing Administration. Notice with comment period.

    Science.gov (United States)

    1981-06-30

    This notice contains performance standards (review elements and factors). We are required by section 1903(r)(6)(E) of the Social Security Act to notify all States of proposed procedures, standards, and other requirements at least one quarter prior to the fiscal year in which the procedures, standards, and other requirements will be used for Medicaid Management Information Systems reapproval reviews. This Notice meets that statutory requirements. By October 1, 1981, we will use the performance standards and existing systems requirements when conducting the annual review of State system performance.

  14. Status of existing federal environmental risk-based standards applicable to Department of Energy operations

    International Nuclear Information System (INIS)

    Bilyard, G.R.; Jonas, R.J.; Wallo, A. III

    1991-01-01

    When conducting its environmental restoration, waste management, and decontamination and decommissioning activities, the US Department of Energy (DOE) must comply with a myriad of regulatory procedures and environmental standards. An assessment of the status of existing federal standards that may be applied to chemical and radioactive substances on DOE sites found substantial gaps and inconsistencies among the existing standards, and technical issues associated with the application of those standards. Of 271 chemical and radioactive substances found to be important across environmental media at the Hanford, Savannah River, and Oak Ridge Sites, 96 (35%) are unregulated by federal regulations and are not covered by DOE guidelines, 48 (18%) are covered by single federal standards or DOE guidelines, and 127 (47%) are covered by multiple regulations or DOE guidelines. Inconsistencies and technical issues among standards include the promulgation of different standards under different regulations for a given substance in an environmental medium, the application of standards for purposes other than originally intended, and the inability to meet standards because of technical limitations. Given the lack of a complete, consistent set of standards or generic procedures for determining applicable standards, and given the existence of inconsistencies and technical issues among the existing set of standards, DOE may be faced with lengthy negotiations of standards on a case-by-case basis. Such negotiations could result in inconsistent cleanup levels, high costs, potential delays, and missed regulatory milestones

  15. Setting Performance Standards for Technical and Nontechnical Competence in General Surgery.

    Science.gov (United States)

    Szasz, Peter; Bonrath, Esther M; Louridas, Marisa; Fecso, Andras B; Howe, Brett; Fehr, Adam; Ott, Michael; Mack, Lloyd A; Harris, Kenneth A; Grantcharov, Teodor P

    2017-07-01

    The objectives of this study were to (1) create a technical and nontechnical performance standard for the laparoscopic cholecystectomy, (2) assess the classification accuracy and (3) credibility of these standards, (4) determine a trainees' ability to meet both standards concurrently, and (5) delineate factors that predict standard acquisition. Scores on performance assessments are difficult to interpret in the absence of established standards. Trained raters observed General Surgery residents performing laparoscopic cholecystectomies using the Objective Structured Assessment of Technical Skill (OSATS) and the Objective Structured Assessment of Non-Technical Skills (OSANTS) instruments, while as also providing a global competent/noncompetent decision for each performance. The global decision was used to divide the trainees into 2 contrasting groups and the OSATS or OSANTS scores were graphed per group to determine the performance standard. Parametric statistics were used to determine classification accuracy and concurrent standard acquisition, receiver operator characteristic (ROC) curves were used to delineate predictive factors. Thirty-six trainees were observed 101 times. The technical standard was an OSATS of 21.04/35.00 and the nontechnical standard an OSANTS of 22.49/35.00. Applying these standards, competent/noncompetent trainees could be discriminated in 94% of technical and 95% of nontechnical performances (P < 0.001). A 21% discordance between technically and nontechnically competent trainees was identified (P < 0.001). ROC analysis demonstrated case experience and trainee level were both able to predict achieving the standards with an area under the curve (AUC) between 0.83 and 0.96 (P < 0.001). The present study presents defensible standards for technical and nontechnical performance. Such standards are imperative to implementing summative assessments into surgical training.

  16. 76 FR 14437 - Economic Simplified Boiling Water Reactor Standard Design: GE Hitachi Nuclear Energy; Issuance of...

    Science.gov (United States)

    2011-03-16

    ... NUCLEAR REGULATORY COMMISSION [NRC-2011-0055] Economic Simplified Boiling Water Reactor Standard Design: GE Hitachi Nuclear Energy; Issuance of Final Design Approval The U.S. Nuclear Regulatory Commission has issued a final design approval (FDA) to GE Hitachi Nuclear Energy (GEH) for the economic...

  17. Energy Performance Certification of Faculty Buildings in Spain: The gap between estimated and real energy consumption

    International Nuclear Information System (INIS)

    Herrando, María; Cambra, David; Navarro, Marcos; Cruz, Lucio de la; Millán, Gema; Zabalza, Ignacio

    2016-01-01

    Highlights: • Most of the Faculty Buildings studied are within the average of CO_2 emissions. • Academic and Research buildings have a similar simulated energy consumption. • Several restrictions found in the official Energy Performance Certification tool. • Average deviation of 30% between estimated and real energy consumption. • Electrical equipment and user behaviour notably increase the energy performance gap. - Abstract: A systematic method has been established to perform and analyse in detail the Energy Performance Certification of 21 Faculty Buildings located at the University of Zaragoza (Spain), according to the transposition of Directive 2010/31/EU. First of all, the problem background and a review of the state-of-the-art of the energy certification in buildings is outlined, regarding both the actual state of the Government regulations and the studies undertaken in several countries to assess the energy performance of different types of buildings, residential and non-residential. A summary of the causes found in other studies for the discrepancies between the estimated (by simulation) and actual energy consumption is shown which is afterwards tested and compared with the results found in the present study. Thereafter, the method followed to undertake the buildings’ Energy Performance Certification is explained, and the main results found together with the discussion are detailed, comparing actual vs. estimated energy consumption in the different case studies and proposing reasons for these deviations. The energy consumption breakdown by uses for several buildings is also analysed, and potential improvements for the simulation software are assessed.

  18. Comparing Performance Standards on the Retention of Words Read Correctly per Minute

    Science.gov (United States)

    Kubina, Richard M., Jr.; Amato, Janelle; Schwilk, Christopher L.; Therrien, William J.

    2008-01-01

    To measure retention of oral reading fluency, three students attending a learning support classroom used a repeating reading strategy with two passages. Each student read one passage to a high performance standard and the other passage to a lower performance standard. Results show it took the students more practice to reach the higher performance…

  19. 40 CFR 450.24 - New source performance standards reflecting the best available demonstrated control technology...

    Science.gov (United States)

    2010-07-01

    ... performance standards reflecting the best available demonstrated control technology (NSPS). Any new source... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards reflecting the best available demonstrated control technology (NSPS). 450.24 Section 450.24 Protection of...

  20. "Circumstance and Proper Timing": Context and the Construction of a Standards Framework for School Principals' Performance.

    Science.gov (United States)

    Louden, William; Wildy, Helen

    1999-01-01

    Professional standards for school principals typically describe an ideal performance in a generalized context. This article describes an alternative method of developing a standards framework, combining qualitative vignettes with probabilistic measurement techniques to provide essential or ideal performance qualities with contextually rich…

  1. Standards Performance Continuum: Development and Validation of a Measure of Effective Pedagogy.

    Science.gov (United States)

    Doherty, R. William; Hilberg, R. Soleste; Epaloose, Georgia; Tharp, Roland G.

    2002-01-01

    Describes the development and validation of the Standards Performance Continuum (SPC) for assessing teacher performance of the Standards for Effective Pedagogy. Three studies involving Florida, California, and New Mexico public school teachers provided evidence of inter-rater reliability, concurrent validity, and criterion-related validity…

  2. 26 CFR 1.23-4 - Performance and quality standards. [Reserved

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true Performance and quality standards. [Reserved] 1.23-4 Section 1.23-4 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Changes in Rates During A Taxable Year § 1.23-4 Performance and quality standards. [Reserved...

  3. 20 CFR 901.20 - Standards of performance of actuarial services.

    Science.gov (United States)

    2010-04-01

    ... services. 901.20 Section 901.20 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES REGULATIONS... Standards of Performance for Enrolled Actuaries § 901.20 Standards of performance of actuarial services. In the discharge of duties required by ERISA of enrolled actuaries with respect to any plan to which the...

  4. Proceedings of standard model at the energy of present and future accelerators

    International Nuclear Information System (INIS)

    Csikor, F.; Pocsik, G.; Toth, E.

    1992-01-01

    This book contains the proceedings of the Workshop on The Standard Model at the Energy of the Present and Future Accelerators, 27 June - 1 July 1989, Budapest. The Standard Model of strong and electro-weak interactions providing essential insights into the fundamental structure of matter and being the basic building block of further generalizations has a rich content. The Workshop was devoted to discussing topical problems of testing the Standard Model in high energy reactions such as jet physics and fragmentation, new applications and tests of perturbative QCD, CP-violation, B-meson physics and developments in weak decays, some of the future experimental plans and related topics

  5. 78 FR 55781 - Energy Conservation Program: Energy Conservation Standards for Walk-In Coolers and Freezers

    Science.gov (United States)

    2013-09-11

    ... Affiliation docket AFM Corporation AFM Manufacturer 0012.1 Air-Conditioning, Heating, and AHRI Trade... Refrigeration Products LLC. Heatcraft Manufacturer 0058.1, 0069.1 Heating, Air-conditioning & HARDI Trade.... Introduction A. Authority B. Background 1. Current Standards 2. History of Standards Rulemaking for Walk-In...

  6. 78 FR 55889 - Energy Conservation Program: Energy Conservation Standards for Commercial Refrigeration Equipment

    Science.gov (United States)

    2013-09-11

    ... in ANSI/Air- Conditioning and Refrigeration Institute (ARI) Standard 1200-2006, appendix D. [dagger... Manufacturers C. National Benefits II. Introduction A. Authority B. Background 1. Current Standards 2. History... class terminology. ** ``TDA'' is the total display area of the case, as measured in the Air...

  7. Computational Fluid Dynamics and Building Energy Performance Simulation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Tryggvason, T.

    1998-01-01

    An interconnection between a building energy performance simulation program and a Computational Fluid Dynamics program (CFD) for room air distribution will be introduced for improvement of the predictions of both the energy consumption and the indoor environment. The building energy performance...... simulation program requires a detailed description of the energy flow in the air movement which can be obtained by a CFD program. The paper describes an energy consumption calculation in a large building, where the building energy simulation program is modified by CFD predictions of the flow between three...... zones connected by open areas with pressure and buoyancy driven air flow. The two programs are interconnected in an iterative procedure. The paper shows also an evaluation of the air quality in the main area of the buildings based on CFD predictions. It is shown that an interconnection between a CFD...

  8. Solar energy photovoltaic technology: proficiency and performance; L'energie solaire maitrise et performance photovoltaiques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Total is committed to making the best possible of the planet's fossil fuel reserves while fostering the emergence of other solutions, notably by developing effective alternatives. Total involves in photovoltaics when it founded in 1983 Total Energies, renamed Tenesol in 2005, a world leader in the design and installation of photovoltaic solar power systems. This document presents Total's activities in the domain: the global challenge of energy sources and the environment, the energy collecting by photovoltaic electricity, the silicon technology for cell production, solar panels and systems to distribute energy, research and development to secure the future. (A.L.B.)

  9. Energy Performance of Buildings - The European Approach to Sustainability

    DEFF Research Database (Denmark)

    Heiselberg, Per

    2006-01-01

    This paper presents the European approach to improve sustainability in the building sector, which has a very high potential for considerable reduction of energy consumption in the coming years. By approving the Energy Performance in Buildings Directive the European Union has taken a strong...... leadership role in promoting energy efficiency in buildings in Europe, that will be the most powerful instrument developed to date for the building sector in Europe....

  10. Performance of the electron energy-loss spectrometer

    International Nuclear Information System (INIS)

    Tanaka, H.; Huebner, R.H.

    1977-01-01

    Performance characteristics of the electron energy-loss spectrometer incorporating a new high-resolution hemispherical monochromator are reported. The apparatus achieved an energy-resolution of 25 meV in the elastic scattering mode, and angular distributions of elastically scattered electrons were in excellent agreement with previous workers. Preliminary energy-loss spectra for several atmospheric gases demonstrate the excellent versatility and stable operation of the improved system. 12 references

  11. MODELING SIMULATION AND PERFORMANCE STUDY OF GRIDCONNECTED PHOTOVOLTAIC ENERGY SYSTEM

    OpenAIRE

    Nagendra K; Karthik J; Keerthi Rao C; Kumar Raja Pemmadi

    2017-01-01

    This paper presents Modeling Simulation of grid connected Photovoltaic Energy System and performance study using MATLAB/Simulink. The Photovoltaic energy system is considered in three main parts PV Model, Power conditioning System and Grid interface. The Photovoltaic Model is inter-connected with grid through full scale power electronic devices. The simulation is conducted on the PV energy system at normal temperature and at constant load by using MATLAB.

  12. Do Energy Efficiency Standards Improve Quality? Evidence from a Revealed Preference Approach

    Energy Technology Data Exchange (ETDEWEB)

    Houde, Sebastien [Univ. of Maryland, College Park, MD (United States); Spurlock, C. Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-06-01

    Minimum energy efficiency standards have occupied a central role in U.S. energy policy for more than three decades, but little is known about their welfare effects. In this paper, we employ a revealed preference approach to quantify the impact of past revisions in energy efficiency standards on product quality. The micro-foundation of our approach is a discrete choice model that allows us to compute a price-adjusted index of vertical quality. Focusing on the appliance market, we show that several standard revisions during the period 2001-2011 have led to an increase in quality. We also show that these standards have had a modest effect on prices, and in some cases they even led to decreases in prices. For revision events where overall quality increases and prices decrease, the consumer welfare effect of tightening the standards is unambiguously positive. Finally, we show that after controlling for the effect of improvement in energy efficiency, standards have induced an expansion of quality in the non-energy dimension. We discuss how imperfect competition can rationalize these results.

  13. International Standards Development for Marine and Hydrokinetic Renewable Energy - Final Report on Technical Status

    Energy Technology Data Exchange (ETDEWEB)

    Rondorf, Neil E.; Busch, Jason; Kimball, Richard

    2011-10-29

    This report summarizes the progress toward development of International Standards for Marine and Hydrokinetic Renewable Energy, as funded by the U.S. Department of Energy (DOE) under the International Electrotechnical Commission (IEC) Technical Committee 114. The project has three main objectives: 1. Provide funding to support participation of key U.S. industry technical experts in 6 (originally 4) international working groups and/or project teams (the primary standards-making committees) and to attend technical meetings to ensure greater U.S. involvement in the development of these standards. 2. Provide a report to DOE and industry stakeholders summarizing the IEC standards development process for marine and hydrokinetic renewable energy, new international standards and their justifications, and provide standards guidance to industry members. 3. Provide a semi-annual (web-based) newsletter to the marine renewable energy community. The newsletter will educate industry members and stakeholders about the processes, progress, and needs of the US efforts to support the international standards development effort. The newsletter is available at www.TC114.us

  14. A review on energy efficiency standards and labels: present status and implementation possibilities in malaysia

    Directory of Open Access Journals (Sweden)

    T.M.I. Mahlia,

    2017-11-01

    Full Text Available This article is a review on energy efficiency standards  and labels for household electrical appliances around the world. Through the review of other country experiences on energy efficiency standards and labels, we attempt to identify savings possibilities in Malaysian households. The implementation possibilities of standards and labels for various household electrical appliances in Malaysia are also examined. It is found that various household appliances in Malaysia offer some potential in reducing electricity consumption. Finally, it is concluded that there are many advantages for Malaysia to implement the standards and labels for household electrical appliances as soon as possible in order to reduce electricity  bills  and energy  consumption  in Malaysian  households.

  15. Evaluating energy performance in non-domestic buildings : a review

    NARCIS (Netherlands)

    Borgstein, E.H.; Lamberts, R.; Hensen, J.L.M.

    2016-01-01

    Evaluation methods can be used to determine what constitutes good energy performance in a building. With an increasing focus on energy use of buildings worldwide, this evaluation assumes a fundamental importance. This paper provides a comprehensive review of the available methods for analysing,

  16. On the safety performance of the advanced nuclear energy systems

    International Nuclear Information System (INIS)

    Li Shounan

    1999-01-01

    Some features on the safety performances of the Advanced Nuclear Energy Systems are discussed. The advantages and some peculiar problems on the safety of Advanced Nuclear Energy Systems with subcritical nuclear reactor driven by external neutron sources are also pointed out in comparison with conventional nuclear reactors

  17. Performance of cryogenic thermoelectric generators in LNG cold energy utilization

    International Nuclear Information System (INIS)

    Sun Wei; Hu Peng; Chen Zeshao; Jia Lei

    2005-01-01

    The cold energy of liquefied natural gas (LNG) is generally wasted when the LNG is extracted for utilization. This paper proposes cryogenic thermoelectric generators to recover this cold energy. The theoretical performance of the generator has been analyzed. An analytical method and numerical method of calculation of the optimum parameters of the generator have been demonstrated

  18. Performance gaps in energy consumption : household groups and building characteristics

    NARCIS (Netherlands)

    van den Brom, P.I.; Meijer, A.; Visscher, H.J.

    2017-01-01

    The difference between actual and calculated energy is called the ‘energy-performance gap’. Possible explanations for this gap are construction mistakes, improper adjusting of equipment, excessive simplification in simulation models and occupant behaviour. Many researchers and governmental

  19. Energy consumption performance analysis of electrical mitad at ...

    African Journals Online (AJOL)

    The Injera baking electrical mitad is the most energy-consuming device in every household in Ethiopia. This research presents a detail engineering study on the energy-consumption performance of existing electrical mitad in Mekelle city. The research work considered thirty-one electrical mitad from different workshops in ...

  20. Performance and Energy Metabolism by Broiler Chickens Fed Maize ...

    African Journals Online (AJOL)

    Studies were conducted to evaluate the effect of replacing maize grain with different dietary levels of maize and millet offals on performance and energy metabolism in broiler chickens. Proximate composition and metabolizable energy (ME) values were determined. Feeding trial was also conducted to comparemaize and ...

  1. Use of performance standards in behavioral health carve-out contracts among Fortune 500 firms.

    Science.gov (United States)

    Merrick, E L; Garnick, D W; Horgan, C M; Goldin, D; Hodgkin, D; Sciegaj, M

    1999-06-25

    To determine the prevalence and nature of performance standards in specialty managed behavioral healthcare contracts among Fortune 500 companies. This was a cross-sectional survey of all companies listed on the Fortune 500 during 1994, 1995, or both. From April 1997 to May 1998 we conducted a mailed survey with phone follow-up. Of the 68% of firms that responded, over one third reported carve-out contracts. The survey focused on whether companies had behavioral health carve-out contracts with specialty vendors and characteristics of these contracts, including the use of performance standards. More than three quarters of the Fortune 500 companies reporting specialty behavioral healthcare contracts used at least one performance standard. Most common were administrative standards (70.2%) and customer service standards (69.4%). About half of the companies used quality standards, whereas only a third used provider-related standards. Most (58.8%) companies using performance standards also specified financial consequences. Larger Fortune 500 firms were significantly more likely to use performance standards. Risk contracts and contracts that included all covered employees were also more likely to include some categories of standards. Administrative and customer service standards may be most common because companies find it easier to specify those standards, especially compared with clinical quality measures. To the extent that employers want to obtain the most value from their behavioral healthcare purchasing, we expect that more will begin to adopt quality standards in their contracts, especially as performance measures become more refined. Reliance on accreditation, however, is an alternative approach for employers.

  2. From Sensor Networks to Internet of Things. Bluetooth Low Energy, a Standard for This Evolution

    Directory of Open Access Journals (Sweden)

    Diego Hortelano

    2017-02-01

    Full Text Available Current sensor networks need to be improved and updated to satisfy new essential requirements of the Internet of Things, where cutting-edge applications will appear. These requirements are: total coverage, zero fails (high performance, scalability and sustainability (hardware and software. We are going to evaluate Bluetooth Low Energy as wireless transmission technology and as the ideal candidate for these improvements, due to its low power consumption, its low cost radio chips and its ability to communicate with users directly, using their smartphones or smartbands. However, this technology is relatively recent, and standard network topologies are not able to fulfil its new requirements. To address these shortcomings, the implementation of other more flexible topologies (as the mesh topology will be very interesting. After studying it in depth, we have identified certain weaknesses, for example, specific devices are needed to provide network scalability, and the need to choose between high performance or sustainability. In this paper, after presenting the studies carried out on these new technologies, we propose a new packet format and a new BLE mesh topology, with two different configurations: Individual Mesh and Collaborative Mesh. Our results show how this topology improves the scalability, sustainability, coverage and performance.

  3. From Sensor Networks to Internet of Things. Bluetooth Low Energy, a Standard for This Evolution.

    Science.gov (United States)

    Hortelano, Diego; Olivares, Teresa; Ruiz, M Carmen; Garrido-Hidalgo, Celia; López, Vicente

    2017-02-14

    Current sensor networks need to be improved and updated to satisfy new essential requirements of the Internet of Things, where cutting-edge applications will appear. These requirements are: total coverage, zero fails (high performance), scalability and sustainability (hardware and software). We are going to evaluate Bluetooth Low Energy as wireless transmission technology and as the ideal candidate for these improvements, due to its low power consumption, its low cost radio chips and its ability to communicate with users directly, using their smartphones or smartbands. However, this technology is relatively recent, and standard network topologies are not able to fulfil its new requirements. To address these shortcomings, the implementation of other more flexible topologies (as the mesh topology) will be very interesting. After studying it in depth, we have identified certain weaknesses, for example, specific devices are needed to provide network scalability, and the need to choose between high performance or sustainability. In this paper, after presenting the studies carried out on these new technologies, we propose a new packet format and a new BLE mesh topology, with two different configurations: Individual Mesh and Collaborative Mesh . Our results show how this topology improves the scalability, sustainability, coverage and performance.

  4. From Sensor Networks to Internet of Things. Bluetooth Low Energy, a Standard for This Evolution

    Science.gov (United States)

    Hortelano, Diego; Olivares, Teresa; Ruiz, M. Carmen; Garrido-Hidalgo, Celia; López, Vicente

    2017-01-01

    Current sensor networks need to be improved and updated to satisfy new essential requirements of the Internet of Things, where cutting-edge applications will appear. These requirements are: total coverage, zero fails (high performance), scalability and sustainability (hardware and software). We are going to evaluate Bluetooth Low Energy as wireless transmission technology and as the ideal candidate for these improvements, due to its low power consumption, its low cost radio chips and its ability to communicate with users directly, using their smartphones or smartbands. However, this technology is relatively recent, and standard network topologies are not able to fulfil its new requirements. To address these shortcomings, the implementation of other more flexible topologies (as the mesh topology) will be very interesting. After studying it in depth, we have identified certain weaknesses, for example, specific devices are needed to provide network scalability, and the need to choose between high performance or sustainability. In this paper, after presenting the studies carried out on these new technologies, we propose a new packet format and a new BLE mesh topology, with two different configurations: Individual Mesh and Collaborative Mesh. Our results show how this topology improves the scalability, sustainability, coverage and performance. PMID:28216560

  5. Enabling Detailed Energy Analyses via the Technology Performance Exchange: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Studer, D.; Fleming, K.; Lee, E.; Livingood, W.

    2014-08-01

    One of the key tenets to increasing adoption of energy efficiency solutions in the built environment is improving confidence in energy performance. Current industry practices make extensive use of predictive modeling, often via the use of sophisticated hourly or sub-hourly energy simulation programs, to account for site-specific parameters (e.g., climate zone, hours of operation, and space type) and arrive at a performance estimate. While such methods are highly precise, they invariably provide less than ideal accuracy due to a lack of high-quality, foundational energy performance input data. The Technology Performance Exchange was constructed to allow the transparent sharing of foundational, product-specific energy performance data, and leverages significant, external engineering efforts and a modular architecture to efficiently identify and codify the minimum information necessary to accurately predict product energy performance. This strongly-typed database resource represents a novel solution to a difficult and established problem. One of the most exciting benefits is the way in which the Technology Performance Exchange's application programming interface has been leveraged to integrate contributed foundational data into the Building Component Library. Via a series of scripts, data is automatically translated and parsed into the Building Component Library in a format that is immediately usable to the energy modeling community. This paper (1) presents a high-level overview of the project drivers and the structure of the Technology Performance Exchange; (2) offers a detailed examination of how technologies are incorporated and translated into powerful energy modeling code snippets; and (3) examines several benefits of this robust workflow.

  6. e/sup +/e/sup -/ interactions at very high energy: searching beyond the standard model

    Energy Technology Data Exchange (ETDEWEB)

    Dorfan, J.

    1983-04-01

    These lectures discuss e/sup +/e/sup -/ interactions at very high energies with a particular emphasis on searching the standard model which we take to be SU(3)/sub color/..lambda.. SU(2) ..lambda.. U(1). The highest e/sup +/e/sup -/ collision energy exploited to date is at PETRA where data have been taken at 38 GeV. We will consider energies above this to be the very high energy frontier. The lectures will begin with a review of the collision energies which will be available in the upgraded machines of today and the machines planned for tomorrow. Without going into great detail, we will define the essential elements of the standard model. We will remind ourselves that some of these essential elements have not yet been verified and that part of the task of searching beyond the standard model will involve experiments aimed at this verification. For if we find the standard model lacking, then clearly we are forced to find an alternative. So we will investigate how the higher energy e/sup +/e/sup -/ collisions can be used to search for the top quark, the neutral Higgs scalar, provide true verification of the non-Abelian nature of QCD, etc. Having done this we will look at tests of models involving simple extensions of the standard model. Models considered are those without a top quark, those with charged Higgs scalars, with multiple and/or composite vector bosons, with additional generations and possible alternative explanations for the PETRA three jet events which don't require gluon bremsstrahlung. From the simple extensions of the standard model we will move to more radical alternatives, alternatives which have arisen from the unhappiness with the gauge hierarchy problem of the standard model. Technicolor, Supersymmetry and composite models will be discussed. In the final section we will summarize what the future holds in terms of the search beyond the standard model.

  7. e+e- interactions at very high energy: searching beyond the standard model

    International Nuclear Information System (INIS)

    Dorfan, J.

    1983-04-01

    These lectures discuss e + e - interactions at very high energies with a particular emphasis on searching the standard model which we take to be SU(3)/sub color/Λ SU(2) Λ U(1). The highest e + e - collision energy exploited to date is at PETRA where data have been taken at 38 GeV. We will consider energies above this to be the very high energy frontier. The lectures will begin with a review of the collision energies which will be available in the upgraded machines of today and the machines planned for tomorrow. Without going into great detail, we will define the essential elements of the standard model. We will remind ourselves that some of these essential elements have not yet been verified and that part of the task of searching beyond the standard model will involve experiments aimed at this verification. For if we find the standard model lacking, then clearly we are forced to find an alternative. So we will investigate how the higher energy e + e - collisions can be used to search for the top quark, the neutral Higgs scalar, provide true verification of the non-Abelian nature of QCD, etc. Having done this we will look at tests of models involving simple extensions of the standard model. Models considered are those without a top quark, those with charged Higgs scalars, with multiple and/or composite vector bosons, with additional generations and possible alternative explanations for the PETRA three jet events which don't require gluon bremsstrahlung. From the simple extensions of the standard model we will move to more radical alternatives, alternatives which have arisen from the unhappiness with the gauge hierarchy problem of the standard model. Technicolor, Supersymmetry and composite models will be discussed. In the final section we will summarize what the future holds in terms of the search beyond the standard model

  8. Data and analytics to inform energy retrofit of high performance buildings

    International Nuclear Information System (INIS)

    Hong, Tianzhen; Yang, Le; Hill, David; Feng, Wei

    2014-01-01

    Highlights: • High performance buildings can be retrofitted using measured data and analytics. • Data of energy use, systems operating and environmental conditions are needed. • An energy data model based on the ISO Standard 12655 is key for energy benchmarking. • Three types of analytics are used: energy profiling, benchmarking, and diagnostics. • The case study shows 20% of electricity can be saved by retrofit. - Abstract: Buildings consume more than one-third of the world’s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis – energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high

  9. Calculating Impacts of Energy Standards on Energy Demand in U.S. Buildings under Uncertainty with an Integrated Assessment Model: Technical Background Data

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Daly, Don S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hathaway, John E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lansing, Carina S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Ying [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McJeon, Haewon C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Moss, Richard H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Patel, Pralit L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Peterson, Marty J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rice, Jennie S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhou, Yuyu [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-06

    This report presents data and assumptions employed in an application of PNNL’s Global Change Assessment Model with a newly-developed Monte Carlo analysis capability. The model is used to analyze the impacts of more aggressive U.S. residential and commercial building-energy codes and equipment standards on energy consumption and energy service costs at the state level, explicitly recognizing uncertainty in technology effectiveness and cost, socioeconomics, presence or absence of carbon prices, and climate impacts on energy demand. The report provides a summary of how residential and commercial buildings are modeled, together with assumptions made for the distributions of state–level population, Gross Domestic Product (GDP) per worker, efficiency and cost of residential and commercial energy equipment by end use, and efficiency and cost of residential and commercial building shells. The cost and performance of equipment and of building shells are reported separately for current building and equipment efficiency standards and for more aggressive standards. The report also details assumptions concerning future improvements brought about by projected trends in technology.

  10. Status of existing federal environmental risk-based standards applicable to Department of Energy operations

    International Nuclear Information System (INIS)

    Bilyard, G.R.

    1991-09-01

    When conducting its environmental restoration, waste management, and decontamination and decommissioning activities, the US Department of Energy (DOE) must comply with a myriad of regulatory procedures and environmental standards. This paper assesses the status of existing federal risk-based standards that may be applied to chemical and radioactive substances on DOE sites. Gaps and inconsistencies among the existing standards and the technical issues associated with the application of those standards are identified. Finally, the implications of the gaps, inconsistencies, and technical issues on DOE operations are discussed, and approaches to resolving the gaps, inconsistencies, and technical issues are identified. 6 refs

  11. Decomposing Fuel Economy and Greenhouse Gas Regulatory Standards in the Energy Conversion Efficiency and Tractive Energy Domain

    Energy Technology Data Exchange (ETDEWEB)

    Pannone, Greg [Novation Analytics; Thomas, John F [ORNL; Reale, Michael [Novation Analytics; Betz, Brian [Novation Analytics

    2017-01-01

    The three foundational elements that determine mobile source energy use and tailpipe carbon dioxide (CO2) emissions are the tractive energy requirements of the vehicle, the on-cycle energy conversion efficiency of the propulsion system, and the energy source. The tractive energy requirements are determined by the vehicle's mass, aerodynamic drag, tire rolling resistance, and parasitic drag. Oncycle energy conversion of the propulsion system is dictated by the tractive efficiency, non-tractive energy use, kinetic energy recovery, and parasitic losses. The energy source determines the mobile source CO2 emissions. For current vehicles, tractive energy requirements and overall energy conversion efficiency are readily available from the decomposition of test data. For future applications, plausible levels of mass reduction, aerodynamic drag improvements, and tire rolling resistance can be transposed into the tractive energy domain. Similarly, by combining thermodynamic, mechanical efficiency, and kinetic energy recovery fundamentals with logical proxies, achievable levels of energy conversion efficiency can be established to allow for the evaluation of future powertrain requirements. Combining the plausible levels of tractive energy and on-cycle efficiency provides a means to compute sustainable vehicle and propulsion system scenarios that can achieve future regulations. Using these principles, the regulations established in the United States (U.S.) for fuel consumption and CO2 emissions are evaluated. Fleet-level scenarios are generated and compared to the technology deployment assumptions made during rule-making. When compared to the rule-making assumptions, the results indicate that a greater level of advanced vehicle and propulsion system technology deployment will be required to achieve the model year 2025 U.S. standards for fuel economy and CO2 emissions.

  12. 76 FR 20089 - Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts

    Science.gov (United States)

    2011-04-11

    ... discussed the following major issues at the public meeting: the pros and cons of various efficiency metrics... of Energy, Building Technologies Program, Mailstop EE-2J, 1000 Independence Avenue, SW., Washington... copies. 4. Hand Delivery/Courier: Ms. Brenda Edwards, U.S. Department of Energy, Building Technologies...

  13. 75 FR 41102 - Energy Conservation Program: Energy Conservation Standards for Furnace Fans: Reopening of Public...

    Science.gov (United States)

    2010-07-15

    ... Furnace Fans: Reopening of Public Comment Period AGENCY: Office of Energy Efficiency and Renewable Energy... work of residential heating and cooling systems (``furnace fans''). The comment period closed on July 6... information relevant to the furnace fan rulemaking will be accepted until July 27, 2010. ADDRESSES: Interested...

  14. Alternative test method to assess the energy performance of frost-free refrigerating appliances

    International Nuclear Information System (INIS)

    Hermes, Christian J.L.; Melo, Cláudio; Knabben, Fernando T.

    2013-01-01

    This paper outlines an alternative test method to evaluate the energy consumption of frost-free refrigerators and freezers for residential applications. While the standardized methods require the refrigerating appliance to be kept running according to its onboard control system, which usually drives the refrigerator through an on–off cycling pattern, the proposed approach assesses the refrigerator energy performance in the steady-state regime, being therefore much faster and more reliable. In this procedure, the cooling capacity is matched to the cooling loads by PID-controlled electrical heaters installed within the refrigerated compartments, so that the compartment temperatures are kept at the desired standardized levels. Comparisons between the experimental results obtained using the steady-state energy test and the standardized procedures showed that the former follows closely the trends observed for the latter. - Highlights: ► An alternative test method to assess the energy consumption of refrigerators is proposed. ► PID-controlled electrical heaters were installed within the compartments. ► Steady-state and ISO energy tests were performed and compared. ► Both proposed and standardized test procedures showed similar trends.

  15. Super Energy Savings Performance Contracts: Federal Energy Management Program (FEMP) Program Overview (revision)

    International Nuclear Information System (INIS)

    Pitchford, P.

    2001-01-01

    This four-page publication describes the U.S. Department of Energy's (DOE's) streamlined energy savings performance contracting, or ''Super ESPC,'' process, which is managed by DOE's Federal Energy Management Program (FEMP). Under a Super ESPC, a qualifying energy service company (ESCO) from the private sector pays for energy efficiency improvements or advanced renewable energy technologies (e.g., photovoltaic systems, wind turbines, or geothermal heat pumps, among others) for a facility of a government agency. The ESCO is then repaid over time from the agency's resulting energy cost savings. Delivery orders under these contracts specify the level of performance (energy savings) and the repayment schedule; the contract term can be up to 25 years, although many Super ESPCs are for about 10 years or less

  16. Study on residential appliances energy efficiency standards Refrigerators, air-conditioners, incandescent lamps, fluorescent lamps, color TVs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.G.; Cho, S.K.; Choi, S.H.; Jung, B.M.; Han, S.B.; Kim, K.D. [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    The energy efficiency standards and rating act, as amended by the rational energy utilization act, provides energy efficiency standards and ratings for 6 types of consumer products(refrigerators, air-conditioners, fluorescent lamps, incandescent lamps, ballasts and cars) authorizes the Ministry of Trade, Industry and Energy(MOTIE) to prescribe amended or new energy efficiency standards and rating standards. This study was initiated by the KIER in 1992. KIER`s assessment of the standards is designed to evaluate their statistical and engineering analysis according to Korean(Industrial) Standards(KS). And to make distinction between the poor efficiency and good efficiency models, 5 grades are classified depending on their tested energy efficiency. This year, based on our analysis, MOTIE mandated updated standards for refrigerators, air-conditioners, incandescent lamps, and fluorescent lamps. Also the objective of this study is to set the energy efficiency standards and to grade for color TV sets. (author). 37 refs., 89 figs., 85 tabs.

  17. Measure Guideline. Energy-Efficient Window Performance and Selection

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, John [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR; Haglund, Kerry [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR

    2012-11-01

    This document provides guidelines for the selection of energy-efficient windows in new and existing residential construction in all U.S. climate zones. It includes information on window products, their attributes and performance. It provides cost/benefit information on window energy savings as well as information on non-energy benefits such as thermal comfort and reduced HVAC demands. The report also provides information on energy impacts of design decisions such as window orientation, total glazing area and shading devices and conditions. Information on resources for proper window installation is included as well.

  18. Deep Energy Retrofit Performance Metric Comparison: Eight California Case Studies

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisher, Jeremy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-06-01

    In this paper we will present the results of monitored annual energy use data from eight residential Deep Energy Retrofit (DER) case studies using a variety of performance metrics. For each home, the details of the retrofits were analyzed, diagnostic tests to characterize the home were performed and the homes were monitored for total and individual end-use energy consumption for approximately one year. Annual performance in site and source energy, as well as carbon dioxide equivalent (CO2e) emissions were determined on a per house, per person and per square foot basis to examine the sensitivity to these different metrics. All eight DERs showed consistent success in achieving substantial site energy and CO2e reductions, but some projects achieved very little, if any source energy reduction. This problem emerged in those homes that switched from natural gas to electricity for heating and hot water, resulting in energy consumption dominated by electricity use. This demonstrates the crucial importance of selecting an appropriate metric to be used in guiding retrofit decisions. Also, due to the dynamic nature of DERs, with changes in occupancy, size, layout, and comfort, several performance metrics might be necessary to understand a project’s success.

  19. Energy Performance Indicators in the Swedish Building Procurement Process

    Directory of Open Access Journals (Sweden)

    Ingrid Allard

    2017-10-01

    Full Text Available In Sweden, all new buildings need to comply with the National Board of Housing, Building and Planning’s requirement on specific purchased energy (kWh/m2. Accordingly, this indicator is often used to set design criteria in the building procurement process. However, when energy use is measured in finished buildings, the measurements often deviate significantly from the design calculations. The measured specific purchased energy does not necessarily reflect the responsibility of the building contractor, as it is influenced by the building operation, user behavior and climate. Therefore, Swedish building practitioners may prefer other indicators for setting design criteria in the building procurement process. The aim of this study was twofold: (i to understand the Swedish building practitioners’ perspectives and opinions on seven building energy performance indicators (envelope air leakage, U-values for different building parts, average U-value, specific heat loss, heat loss coefficient, specific net energy, and specific purchased energy; and (ii to understand the consequences for the energy performance of multi-family buildings of using the studied indicators to set criteria in the procurement process. The study involved a Delphi approach and simulations of a multi-family case study building. The studied indicators were discussed in terms of how they may meet the needs of the building practitioners when used to set building energy performance criteria in the procurement process.

  20. Dual-energy CT workflow: multi-institutional consensus on standardization of abdominopelvic MDCT protocols.

    Science.gov (United States)

    Patel, Bhavik N; Alexander, Lauren; Allen, Brian; Berland, Lincoln; Borhani, Amir; Mileto, Achille; Moreno, Courtney; Morgan, Desiree; Sahani, Dushyant; Shuman, William; Tamm, Eric; Tublin, Mitchell; Yeh, Benjamin; Marin, Daniele

    2017-03-01

    To standardize workflow for dual-energy computed tomography (DECT) involving common abdominopelvic exam protocols. 9 institutions (4 rsDECT, 1 dsDECT, 4 both) with 32 participants [average # years (range) in practice and DECT experience, 12.3 (1-35) and 4.6 (1-14), respectively] filled out a single survey (n = 9). A five-point agreement scale (0, 1, 2, 3, 4-contra-, not, mildly, moderately, strongly indicated, respectively) and utilization scale (0-not performing and shouldn't; 1-performing but not clinically useful; 2-performing but not sure if clinically useful; 3-not performing it but would like to; 4-performing and clinically useful) were used. Consensus was considered with a score of ≥2.5. Survey results were discussed over three separate live webinar sessions. 5/9 (56%) institutions exclude large patients from DECT. 2 (40%) use weight, 2 (40%) use transverse dimension, and 1 (20%) uses both. 7/9 (78%) use 50 keV for low and 70 keV for medium monochromatic reconstructed images. DECT is indicated for dual liver [agreement score (AS) 3.78; utilization score (US) 3.22] and dual pancreas in the arterial phase (AS 3.78; US 3.11), mesenteric ischemia/gastrointestinal bleeding in both the arterial and venous phases (AS 2.89; US 2.79), RCC exams in the arterial phase (AS 3.33; US 2.78), and CT urography in the nephrographic phase (AS 3.11; US 2.89). DECT for renal stone and certain single-phase exams is indicated (AS 3.00). DECT is indicated during the arterial phase for multiphasic abdominal exams, nephrographic phase for CTU, and for certain single-phase and renal stone exams.

  1. The status of ANSI N13.11 - The dosimeter performance test standard

    International Nuclear Information System (INIS)

    Sims, C.S.

    1991-01-01

    The standard designated ANSI N13.11 was issued in 1983 and is the basis for the dosimeter performance test associated with the National Voluntary Laboratory Accreditation Program (NVLAP). The standard is important because the Nuclear Regulatory Commission requires that all licensees use personnel dosimeters processed by NVLAP-accredited processors. The standard has undergone review and modifications have been recommended. Historical information concerning the development and utilization of the present standard, ANSI N13.11-1983, is presented. Details associated with the review of the standard (e.g., policy, group selection) are then given. Finally, the modifications recommended by the review group are discussed

  2. Home Performance with ENERGY STAR(R) Exchange

    Energy Technology Data Exchange (ETDEWEB)

    2003-10-01

    Handout for the Energy and Environmental Building Association's Building Solutions 2003 Conference and Expo: Chicago, Illinois, October 2003 The following summaries, provided by implementers of ''Home Performance with ENERGY STAR{reg_sign}'' around the country, are for use in the October 15 discussion during the Energy & Environmental Building Association (EEBA) Building Solutions, 2003 Conference in Chicago. The summaries and session discussions provide an overview of ''Home Performance with ENERGY STAR'', along with results and lessons learned from existing ''Home Performance'' implementers in New York, Wisconsin, Massachusetts, California, and Kansas City. Five future pilot projects set to begin in Georgia/Alabama, Idaho, Missouri, New Jersey and Texas will also be presented and discussed. Session topics will include the use of different training approaches, methods of quality assurance, and the role contractor certification plays in several of the programs. The session will conclude with a roundtable discussion of Home Performance issues by current and emerging implementers, with time for participant questions. ''Home Performance with ENERGY STAR'' uses the growing awareness and credibility of the ENERGY STAR brand to encourage and facilitate whole-house energy improvements in existing homes through self-sustaining energy efficiency programs. Whether you're a state energy official, utility program manager, contractor training professional or efficiency program implementer, you're sure to benefit from the unique presentations and networking opportunities that this session will offer.

  3. How much information disclosure of building energy performance is necessary?

    International Nuclear Information System (INIS)

    Hsu, David

    2014-01-01

    Many different governments have begun to require disclosure of building energy performance, in order to allow owners and prospective buyers to incorporate this information into their investment decisions. These policies, known as disclosure or information policies, require owners to benchmark their buildings and sometimes conduct engineering audits. However, given substantial variation in the cost to disclose different types of information, it is natural to ask: how much and what kind of information about building energy performance should be disclosed, and for what purposes? To answer this question, this paper assembles and cleans a comprehensive panel dataset of New York City multifamily buildings, and analyzes its predictive power using a Bayesian multilevel regression model. Analysis of variance (ANOVA) reveals that building-level variation is the most important factor in explaining building energy use, and that there are few, if any, relationships of building systems to observed energy use. This indicates that disclosure laws requiring benchmarking data may be relatively more useful than engineering audits in explaining the observed energy performance of existing buildings. These results should inform the further development of information disclosure laws. - Highlights: • A comprehensive panel dataset of energy performance and building characteristics was assembled and cleaned. • The effectiveness of the disclosed information to predict building energy performance was tested using a regression model. • Building-level variation has a greater effect than any building characteristic or systems. • Benchmarking data alone predicts energy performance equally as well as both benchmarking and engineering audit data together, and better than audit data alone

  4. Long term energy performance analysis of Egbin thermal power ...

    African Journals Online (AJOL)

    This study is aimed at providing an energy performance analysis of Egbin thermal power plant. The plant operates on Regenerative Rankine cycle with steam as its working fluid .The model equations were formulated based on some performance parameters used in power plant analysis. The considered criteria were plant ...

  5. 77 FR 7281 - Energy Conservation Program: Energy Conservation Standards for Distribution Transformers

    Science.gov (United States)

    2012-02-10

    ... Electrical Efficiencies for all Liquid-Immersed Distribution Transformer Equipment Classes (Compliance... ``customers.'' Customers refer to electric utilities in the case of liquid-immersed transformers, and to... for Determining Energy Efficiency for Distribution Transformers'' published by the National Electrical...

  6. Energy management in production: A novel method to develop key performance indicators for improving energy efficiency

    International Nuclear Information System (INIS)

    May, Gökan; Barletta, Ilaria; Stahl, Bojan; Taisch, Marco

    2015-01-01

    Highlights: • We propose a 7-step methodology to develop firm-tailored energy-related KPIs (e-KPIs). • We provide a practical guide for companies to identify their most important e-KPIs. • e-KPIs support identification of energy efficiency improvement areas in production. • The method employs an action plan for achieving energy saving targets. • The paper strengthens theoretical base for energy-based decision making in manufacturing. - Abstract: Measuring energy efficiency performance of equipments, processes and factories is the first step to effective energy management in production. Thus, enabled energy-related information allows the assessment of the progress of manufacturing companies toward their energy efficiency goals. In that respect, the study addresses this challenge where current industrial approaches lack the means and appropriate performance indicators to compare energy-use profiles of machines and processes, and for the comparison of their energy efficiency performance to that of competitors’. Focusing on this challenge, the main objective of the paper is to present a method which supports manufacturing companies in the development of energy-based performance indicators. For this purpose, we provide a 7-step method to develop production-tailored and energy-related key performance indicators (e-KPIs). These indicators allow the interpretation of cause-effect relationships and therefore support companies in their operative decision-making process. Consequently, the proposed method supports the identification of weaknesses and areas for energy efficiency improvements related to the management of production and operations. The study therefore aims to strengthen the theoretical base necessary to support energy-based decision making in manufacturing industries

  7. Renewable portfolio standards and cost-effective energy-efficiency investment

    International Nuclear Information System (INIS)

    Mahone, A.; Woo, C.K.; Williams, J.; Horowitz, I.

    2009-01-01

    Renewable portfolio standards (RPSs) and mandates to invest in cost-effective energy efficiency (EE) are increasingly popular policy tools to combat climate change and dependence on fossil fuels. These supply-side and demand-side policies, however, are often uncoordinated. Using California as a case in point, this paper demonstrates that states could improve resource allocation if these two policies were coordinated by incorporating renewable-energy procurement cost into the cost-effectiveness determination for EE investment. In particular, if renewable energy is relatively expensive when compared to conventional energy, increasing the RPS target raises the cost-effective level of EE investment

  8. The performance of energy efficient residential building envelope systems

    Energy Technology Data Exchange (ETDEWEB)

    Proskiw, G.

    1996-08-01

    The adequacy and durability of residential building envelope systems under actual field conditions were evaluated. A building envelope offers protection from cold, heat, moisture, wind and noise. However, they are exposed to thermal, structural, and moisture stresses and their performance can degrade over time. Envelope performance was evaluated at 20 energy efficient and four conventional, detached modern homes in Winnipeg, Canada. The three complementary measurement tools were wood moisture content (WMC) of framing members, thermographic examinations, and airtightness tests. As expected, energy efficient building envelope systems performed better than the conventional systems. No evidence of envelope degradation was found in any of the energy efficient houses. The building envelopes using polyethylene air barriers performed slightly better than those which used the airtight drywall approach, although both were considered satisfactory. WMC levels were a bit lower in the polyethylene-clad house. 1 ref., 1 tab.

  9. Dynamic performance analysis of two regional Nuclear Hybrid Energy Systems

    International Nuclear Information System (INIS)

    Garcia, Humberto E.; Chen, Jun; Kim, Jong S.; Vilim, Richard B.; Binder, William R.; Bragg Sitton, Shannon M.; Boardman, Richard D.; McKellar, Michael G.; Paredis, Christiaan J.J.

    2016-01-01

    In support of more efficient utilization of clean energy generation sources, including renewable and nuclear options, HES (hybrid energy systems) can be designed and operated as FER (flexible energy resources) to meet both electrical and thermal energy needs in the electric grid and industrial sectors. These conceptual systems could effectively and economically be utilized, for example, to manage the increasing levels of dynamic variability and uncertainty introduced by VER (variable energy resources) such as renewable sources (e.g., wind, solar), distributed energy resources, demand response schemes, and modern energy demands (e.g., electric vehicles) with their ever changing usage patterns. HES typically integrate multiple energy inputs (e.g., nuclear and renewable generation) and multiple energy outputs (e.g., electricity, gasoline, fresh water) using complementary energy conversion processes. This paper reports a dynamic analysis of two realistic HES including a nuclear reactor as the main baseload heat generator and to assess the local (e.g., HES owners) and system (e.g., the electric grid) benefits attainable by their application in scenarios with multiple commodity production and high renewable penetration. It is performed for regional cases – not generic examples – based on available resources, existing infrastructure, and markets within the selected regions. This study also briefly addresses the computational capabilities developed to conduct such analyses. - Highlights: • Hybrids including renewables can operate as dispatchable flexible energy resources. • Nuclear energy can address high variability and uncertainty in energy systems. • Nuclear hybrids can reliably provide grid services over various time horizons. • Nuclear energy can provide operating reserves and grid inertia under high renewables. • Nuclear hybrids can greatly reduce GHG emissions and support grid and industry needs.

  10. Energy dependence of an ionization chamber with parallel plates in standard gamma and x-radiation fields

    International Nuclear Information System (INIS)

    Batistella, M.A.; Caldas, L.V.E.

    1988-09-01

    The characteristics of low energy X-radiation standard fields were determined and the energy dependence of a ionization chamber of the superficial type, with parallel plates and fixed volume, normally utilized in the dosimetry at the Radiotherapy level was studied. The possibility of adaptation of this chamber type for use in gamma radiation dosimetry was verified. Different thickness Lucite build-up caps, from 2.0 up to 5.5 mm, were produced and tested in 60 Co and 137 Cs gamma radiation fields. This type of detector, with the adequate build-up cap, presented a performance comparable to that of the thimble type ionization chamber. It was concluded that it is not necessary to use different kinds of chambers for each high and mean energy interval. The superficial chamber, specially produced to detect low energy X-radiation, may be adapted to detect gamma radiation. (author) [pt

  11. Integrated energy system for a high performance building

    Science.gov (United States)

    Jaczko, Kristen

    Integrated energy systems have the potential to reduce of the energy consumption of residential buildings in Canada. These systems incorporate components to meet the building heating, cooling and domestic hot water load into a single system in order to reduce energy losses. An integrated energy system, consisting of a variable speed heat pump, cold and hot thermal storage tanks, a photovoltaic/thermal (PV/T) collector array and a battery bank, was designed for the Queen's Solar Design Team's (QSDT) test house. The system uses a radiant floor to provide space- heating and sensible cooling and a dedicated outdoor air system provides ventilation and dehumidifies the incoming fresh air. The test house, the Queen's Solar Education Centre (QSEC), and the integrated energy system were both modelled in TRNSYS. Additionally, a new TRNSYS Type was developed to model the PV/T collectors, enabling the modeling of the collection of energy from the ambient air. A parametric study was carried out in TRNSYS to investigate the effect of various parameters on the overall energy performance of the system. These parameters included the PV/T array size and the slope of the collectors, the heat pump source and load-side inlet temperature setpoints, the compressor speed control and the size of the thermal storage tanks and the battery bank. The controls of the heat pump were found to have a large impact on the performance of the integrated energy system. For example, a low evaporator setpoint improved the overall free energy ratio (FER) of the system but the heat pump performance was lowered. Reducing the heat loss of the PV/T panels was not found to have a large effect on the system performance however, as the heat pump is able to lower the inlet collector fluid temperature, thus reducing thermal losses. From the results of the sensitivity study, a recommended system model was created and this system had a predicted FER of 77.9% in Kingston, Ontario, neglecting the energy consumption of

  12. Energy Efficiency in Ethernet Passive Optical Networks (EPONs): Protocol Design and Performance Evaluation

    DEFF Research Database (Denmark)

    Yan, Ying; Dittmann, Lars

    2011-01-01

    a suitable wakeup time scheduler at the Optical Line Terminal (OLT). A generic EPON system is considered, which is composed of an OLT and several ONUs that are EMM enabled. An energy consumption optimization problem aimed at saving energy is proposed and two heuristic sleep mode scheduling policies......As concerns about energy consumption grow, the power consumption of the EPON becomes a matter of increasing importance. In respect of energy efficiency, the current standard has no management protocols aiming to reduce power consumption in EPONs. In this paper, we propose an Energy Management...... and guaranteeing the network performance at the same time. Simulation results show that an EMM-based EPON with well designed scheduling disciplines is essential to achieving significant energy saving while meeting the delay constraint....

  13. Development of an Enhanced Payback Function for the Superior Energy Performance Program

    Energy Technology Data Exchange (ETDEWEB)

    Therkelsen, Peter; Rao, Prakash; McKane, Aimee; Sabouni, Ridah; Sheihing, Paul

    2015-08-03

    The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This paper analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.

  14. Impact of neighborhood design on energy performance and GHG emissions

    International Nuclear Information System (INIS)

    Hachem, Caroline

    2016-01-01

    Highlights: • Energy use and GHG emissions of different neighborhood designs are investigated. • Improving buildings energy performance reduces energy use and GHG emissions by 75%. • Density as isolated factor has limited effect on transport on per capita basis. • Distance to central business district impacts transport GHG emission significantly. - Abstract: This paper presents an innovative and holistic approach to the analysis of the impact of selected design parameters of a new solar community on its environmental performance, in terms of energy efficiency and carbon footprint (green-house gas (GHG) emissions). The design parameters include energy performance level of buildings, density, type of the neighborhood (mixed-use vs residential), location of the commercial center relative to residential areas and the design of the streets. Energy performance is measured as the balance between overall energy consumption for building operations (assuming an all-electric neighborhood) and electricity generation potential through integration of PV panels on available roof surfaces. Greenhouse gas emissions are those associated with building operations and transport. Results of simulations carried out on prototype neighborhoods located in the vicinity of Calgary, Alberta, Canada indicate that, while adopting high-energy efficiency measures can reduce the buildings’ impact by up to 75% in terms of energy consumption and GHG emissions, transport still has a large environmental impact. The parameters of highest impact on transport and its associated GHG emissions are the design of the neighborhood and the distance to the business center. Density, as isolated parameter, has a modest effect on the selected mode of transportation, in terms of using private or public transportation. While this study relates to a specific location and a range of design assumptions, the methodology employed can serve as a template for evaluating design alternatives of new sustainable

  15. Energy content estimation by collegians for portion standardized foods frequently consumed in Korea.

    Science.gov (United States)

    Kim, Jin; Lee, Hee Jung; Lee, Hyun Jung; Lee, Sun Ha; Yun, Jee-Young; Choi, Mi-Kyeong; Kim, Mi-Hyun

    2014-01-01

    The purpose of this study is to estimate Korean collegians' knowledge of energy content in the standard portion size of foods frequently consumed in Korea and to investigate the differences in knowledge between gender groups. A total of 600 collegians participated in this study. Participants' knowledge was assessed based on their estimation on the energy content of 30 selected food items with their actual-size photo images. Standard portion size of food was based on 2010 Korean Dietary Reference Intakes, and the percentage of participants who accurately estimated (that is, within 20% of the true value) the energy content of the standard portion size was calculated for each food item. The food for which the most participants provided the accurate estimation was ramyun (instant noodles) (67.7%), followed by cooked rice (57.8%). The proportion of students who overestimated the energy content was highest for vegetables (68.8%) and beverages (68.1%). The proportion of students who underestimated the energy content was highest for grains and starches (42.0%) and fruits (37.1%). Female students were more likely to check energy content of foods that they consumed than male students. From these results, it was concluded that the knowledge on food energy content was poor among collegians, with some gender difference. Therefore, in the future, nutrition education programs should give greater attention to improving knowledge on calorie content and to helping them apply this knowledge in order to develop effective dietary plans.

  16. 76 FR 37407 - Energy Conservation Program: Energy Conservation Standards for Residential Furnaces and...

    Science.gov (United States)

    2011-06-27

    .... Background 1. Current Standards a. Furnaces b. Central Air Conditioners and Heat Pumps 2. History of... Compliance Requirements a. Central Air Conditioning and Heat Pumps b. Residential Furnaces 3. Duplication... residential central air conditioners and central air conditioning heat pumps (air conditioners and heat pumps...

  17. 78 FR 25627 - Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards for...

    Science.gov (United States)

    2013-05-02

    ... average life of the product in the type (or class) compared to any increase in the price of, or in the... well as the market penetration of such equipment. b. Three-Phase Equipment With an Input Capacity Less... standards. This is done by applying a markup multiplier to the manufacturer's [[Page 25632

  18. 75 FR 10873 - Energy Conservation Program: Energy Conservation Standards for Small Electric Motors

    Science.gov (United States)

    2010-03-09

    ... and Kilowatt Ratings i. Summary 2. Product Classes B. Screening Analysis C. Engineering Analysis 1. Product Classes Analyzed 2. Baseline Models a. Baseline Efficiencies b. Baseline Temperature Rise c... discuss, and receive comments on, these subjects, DOE's proposed product classes, potential standard...

  19. 76 FR 25622 - Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards for...

    Science.gov (United States)

    2011-05-05

    ... also requires that each time the corresponding consensus standard--the American Society of Heating... this analysis, as well as the submission of data and other relevant information. DATES: DOE will accept... Information Number (RIN) 1904-AC47. Comments may be submitted using any of the following methods: 1. Federal e...

  20. 77 FR 32381 - Energy Conservation Program: Energy Conservation Standards for Residential Clothes Washers

    Science.gov (United States)

    2012-05-31

    ... on a CD. It is not necessary to include printed copies. 4. Hand Delivery/Courier: Ms. Brenda Edwards... washers under TSL 3, the first number for consumer impacts refers to the standard in 2015, and the second... the value of CO 2 reductions is based on a global value. Second, the assessments of operating cost...

  1. Solid energy calibration standards for P K-edge XANES: electronic structure analysis of PPh4Br.

    Science.gov (United States)

    Blake, Anastasia V; Wei, Haochuan; Donahue, Courtney M; Lee, Kyounghoon; Keith, Jason M; Daly, Scott R

    2018-03-01

    P K-edge X-ray absorption near-edge structure (XANES) spectroscopy is a powerful method for analyzing the electronic structure of organic and inorganic phosphorus compounds. Like all XANES experiments, P K-edge XANES requires well defined and readily accessible calibration standards for energy referencing so that spectra collected at different beamlines or under different conditions can be compared. This is especially true for ligand K-edge X-ray absorption spectroscopy, which has well established energy calibration standards for Cl (Cs 2 CuCl 4 ) and S (Na 2 S 2 O 3 ·5H 2 O), but not neighboring P. This paper presents a review of common P K-edge XANES energy calibration standards and analysis of PPh 4 Br as a potential alternative. The P K-edge XANES region of commercially available PPh 4 Br revealed a single, highly resolved pre-edge feature with a maximum at 2146.96 eV. PPh 4 Br also showed no evidence of photodecomposition when repeatedly scanned over the course of several days. In contrast, we found that PPh 3 rapidly decomposes under identical conditions. Density functional theory calculations performed on PPh 3 and PPh 4 + revealed large differences in the molecular orbital energies that were ascribed to differences in the phosphorus oxidation state (III versus V) and molecular charge (neutral versus +1). Time-dependent density functional theory calculations corroborated the experimental data and allowed the spectral features to be assigned. The first pre-edge feature in the P K-edge XANES spectrum of PPh 4 Br was assigned to P 1s → P-C π* transitions, whereas those at higher energy were P 1s → P-C σ*. Overall, the analysis suggests that PPh 4 Br is an excellent alternative to other solid energy calibration standards commonly used in P K-edge XANES experiments.

  2. Performance of fuel cell for energy supply of passive house

    Energy Technology Data Exchange (ETDEWEB)

    Badea, G.; Felseghi, R. A., E-mail: Raluca.FELSEGHI@insta.utcluj.ro; Mureşan, D.; Naghiu, G. [Technical University of Cluj-Napoca, Building Services Engineering Department, Bd. December 21, no. 128-130, 400600, Cluj-Napoca (Romania); Răboacă, S. M. [National R& D Institute for Cryogenic and Isotopic Technologies, str. Uzinei, no. 4, Rm. Vălcea, 240050 (Romania); Aşchilean, I. [SC ACI Cluj SA, Avenue Dorobanţilor, no. 70, 400609, Cluj-Napoca (Romania)

    2015-12-23

    Hydrogen technology and passive house represent two concepts with a remarkable role for the efficiency and decarbonisation of energy systems in the residential buildings area. Through design and functionality, the passive house can make maximum use of all available energy resources. One of the solutions to supply energy of these types of buildings is the fuel cell, using this technology integrated into a system for generating electricity from renewable primary sources, which take the function of backup power (energy reserve) to cover peak load and meteorological intermittents. In this paper is presented the results of the case study that provide an analysis of the energy, environmental and financial performances regarding energy supply of passive house by power generation systems with fuel cell fed with electrolytic hydrogen produced by harnessing renewable energy sources available. Hybrid systems have been configured and operate in various conditions of use for five differentiated locations according to the main areas of solar irradiation from the Romanian map. Global performance of hybrid systems is directly influenced by the availability of renewable primary energy sources - particular geo-climatic characteristics of the building emplacement.

  3. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    International Nuclear Information System (INIS)

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files

  4. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files.

  5. Renewable Energy Certificate and Perform, Achieve, Trade mechanisms to enhance the energy security for India

    International Nuclear Information System (INIS)

    Kumar, Rajesh; Agarwala, Arun

    2013-01-01

    The Renewable Energy Certificate and Perform Achieve Trade mechanisms in India are designed to target energy generation and saving, respectively, in line with Clean Development Mechanism implemented by United Nations Framework Convention on Climate Change. The Renewable Energy Certificate System is a voluntary regulation in India for renewable energy generators and is designed for effective implementation of inter-state transactions by introducing the Renewable Purchase Obligation regulation for consumers and a flexible trading platform for transactions across the country. Another initiative, the Perform Achieve Trade scheme, is an enhanced energy efficiency trading mechanism based on consumption targets that require large energy user sectors to improve efficiency by 1–2% per year. The Perform Achieve Trade programme has introduced mechanisms for the identification of industry sector, designated customer, specific energy consumption and target setting. The Perform Achieve Trade design issues are in test phase in the first cycle of the scheme which will run from 2012 to 2015. This paper discusses key design issues about boundary and target setting for Renewable Energy Certificate and Perform Achieve Trade energy saving certificate (ESCert) A data sharing and trading mechanism for Perform Achieve Trade is also proposed for review and coordination among regulator, designated consumers and traders in the market. - Highlights: ► Renewable Energy Certificate’ and ‘Perform Achieve Trade’ are energy certification programmes. ► REC and PAT programme implementation and the institutional network work are presented. ► The trading and communication network propose for possible linkage between REC, PAT and CDM. ► Independent associations in parallel with CERC and BEE are redefined for two tier review of scheme

  6. The radiation performance standard. A presentation model for ionizing radiation in the living environment

    International Nuclear Information System (INIS)

    Schaap, L.E.J.J.; Bosmans, G.; Van der Graaf, E.R.; Hendriks, Ch.F.

    1998-01-01

    By means of the so-called radiation performance standard (SPN, abbreviated in Dutch) the total radioactivity from building constructions which contributes to the indoor radiation dose can be calculated. The SPN is implemented with related boundary values and is part of the Building Decree ('Bouwbesluit') in the Netherlands. The model, presented in this book, forms the basis of a new Dutch radiation protection standard, to be published by the Dutch Institute for Standardization NEN (formerly NNI). 14 refs

  7. Evaluation of China's local enforcement of energy efficiency standards and labeling programs for appliances and equipment

    International Nuclear Information System (INIS)

    Khanna, Nina Zheng; Zhou, Nan; Fridley, David; Fino-Chen, Cecilia

    2013-01-01

    Aims: This paper aims to evaluate local enforcement of China's mandatory appliance and equipment energy efficiency standards and labeling programs, two increasingly important policies for meeting national energy and carbon reduction targets. The expected energy savings of efficiency standards and labels can be fully realized only with strong enforcement to ensure compliance for all products sold. This paper provides comprehensive retrospective evaluation of the methodologies, results, progress and remaining challenges in pilot enforcement projects initiated in the absence of consistent national check-testing focused on energy efficiency. Scope: This paper's scope is focused on 2006–2009 pilot local check-tests conducted to verify appliance and equipment compliance with China's mandatory energy label and efficiency standards. Conclusions: This paper finds both improvement and some backsliding in compliance rates over time. Compared to earlier efforts, 2009 check-tests covered a wider regional and product scope but demonstrated greater variation in compliance rates. Labeling display and energy efficiency compliance was generally high across regions and most products, but lower compliance rates were observed in less economically developed regions and for lighting and industrial products. Based on these findings, areas for improvement in local awareness, product sampling methodology, check-testing tools and procedures are identified. - Highlights: • China's mandatory standards and labeling crucial to national energy saving goals. • China's 2006–2009 pilot efficiency check-testing for standards and labeling evaluated. • Wider geographic and product scope in 2009, but greater variation in compliance. • Generally high compliance, but lower rates for less economically developed region. • Local check-test capacity improving but methodological challenges remain

  8. ''FASTBUS'': status of development of a standard high speed data acquisition bus for high energy physics

    International Nuclear Information System (INIS)

    Larsen, R.S.

    1977-11-01

    In late 1975 the US NIM Committee initiated a study group, known as the Advanced System Study Group, to review the future data acquisition modular interface requirements for high-energy physics. The final report of this group recommended the development of a new standard system, now known as ''FASTBUS,'' which would have as principal features improved speed by a factor of 10 over CAMAC, more generalized architecture to accommodate distributed parallel processing and fast preprocessing, special scan modes of particular use in high-energy particle detection systems, and standardized bus structures and mechanics. A brief summary of current activity is given. 7 figures, 3 tables

  9. Actual energy consumption in dwellings. The effect of energy performance regulations and occupant behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Guerra Santin, O.

    2010-10-19

    Residential buildings have continuously improved in energy efficiency, partly as a consequence of the introduction of energy regulations in many countries. Although better thermal properties and systems efficiency have lowered energy consumption for space heating in recent decades, substantial differences in energy consumption in similar dwellings are still being observed. These differences in consumption are thought to be caused by differences in occupancy patterns, by quality of construction and by rebound effects. This research addresses the effect of energy performance regulations and occupant behavior on energy consumption for space and water heating in dwellings built after the introduction of the energy performance regulations in the Netherlands. The results of this research show that improving the energy efficiency of buildings alone is not enough to decrease that energy consumption. The large differences found in the use of dwellings indicate that, especially in energy efficient houses, occupant behavior provides an opportunity for further reductions in the energy consumption for space heating which could boost the efforts to conserve energy worldwide.

  10. Accelerating the energy retrofit of commercial buildings using a database of energy efficiency performance

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Hong, Tianzhen; Piette, Mary Ann; Sawaya, Geof; Chen, Yixing; Taylor-Lange, Sarah C.

    2015-01-01

    Small and medium-sized commercial buildings can be retrofitted to significantly reduce their energy use, however it is a huge challenge as owners usually lack of the expertise and resources to conduct detailed on-site energy audit to identify and evaluate cost-effective energy technologies. This study presents a DEEP (database of energy efficiency performance) that provides a direct resource for quick retrofit analysis of commercial buildings. DEEP, compiled from the results of about ten million EnergyPlus simulations, enables an easy screening of ECMs (energy conservation measures) and retrofit analysis. The simulations utilize prototype models representative of small and mid-size offices and retails in California climates. In the formulation of DEEP, large scale EnergyPlus simulations were conducted on high performance computing clusters to evaluate hundreds of individual and packaged ECMs covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and service hot water. The architecture and simulation environment to create DEEP is flexible and can expand to cover additional building types, additional climates, and new ECMs. In this study DEEP is integrated into a web-based retrofit toolkit, the Commercial Building Energy Saver, which provides a platform for energy retrofit decision making by querying DEEP and unearthing recommended ECMs, their estimated energy savings and financial payback. - Highlights: • A DEEP (database of energy efficiency performance) supports building retrofit. • DEEP is an SQL database with pre-simulated results from 10 million EnergyPlus runs. • DEEP covers 7 building types, 6 vintages, 16 climates, and 100 energy measures. • DEEP accelerates retrofit of small commercial buildings to save energy use and cost. • DEEP can be expanded and integrated with third-party energy software tools.

  11. 40 CFR 407.25 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 407.25 Section 407.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE...

  12. 40 CFR 407.35 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 407.35 Section 407.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE...

  13. 40 CFR 407.45 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 407.45 Section 407.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE...

  14. 40 CFR 407.15 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 407.15 Section 407.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE...

  15. 40 CFR 406.25 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 406.25 Section 406.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GRAIN MILLS POINT SOURCE CATEGORY Corn Dry Milling Subcategory § 406.25...

  16. 40 CFR 406.15 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 406.15 Section 406.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GRAIN MILLS POINT SOURCE CATEGORY Corn Wet Milling Subcategory § 406.15...

  17. 40 CFR 421.274 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... times. (e) Sodium hypochlorite filter backwash. NSPS for the Primary Rare Earth Metals Subcategory...) EFFLUENT GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Primary Rare Earth Metals Subcategory § 421.274 Standards of performance for new sources. Any new source subject to this...

  18. 40 CFR 60.2035 - How are these new source performance standards structured?

    Science.gov (United States)

    2010-07-01

    ... standards structured? 60.2035 Section 60.2035 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... source performance standards contain the eleven major components listed in paragraphs (a) through (k) of this section. (a) Preconstruction siting analysis. (b) Waste management plan. (c) Operator training and...

  19. 30 CFR 820.11 - Performance standards: Anthracite mines in Pennsylvania.

    Science.gov (United States)

    2010-07-01

    ... Pennsylvania. 820.11 Section 820.11 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... STANDARDS-ANTHRACITE MINES IN PENNSYLVANIA § 820.11 Performance standards: Anthracite mines in Pennsylvania. Anthracite mines in Pennsylvania, as specified in section 529 of the Act, shall comply with its approved...

  20. 40 CFR 428.65 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Standards of performance for new sources. 428.65 Section 428.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Medium-Sized General Molded...